0% found this document useful (0 votes)
106 views2 pages

P0089 Exceed PRV Valve Open Counter Limit: Fault Code Fault Name

Download as pdf or txt
Download as pdf or txt
Download as pdf or txt
You are on page 1/ 2

DOOSAN DL06/08 T4-Final_ENG_Version : 1.

06

Fault Code Fault Name


P0089 Exceed PRV valve open counter limit

1) Overview

CODE REASON EFFECT

Opening count of pressure relief valve for wear out


E520203-12 CE Lamp On
monitoring had exceeded

Rail pressure sensor connector

No ECU Pin Description


1 260 GND
2 236 Rail pressure signal
3 211 +5V supply

Metering unit connector

No ECU Pin Description


1 258 Metering unit high side
2 283 Metering unit low side

2) Component Location

Metering Pressure Common Rail


Unit Relief Valve Pressure Sensor
DOOSAN DL06/08 T4-Final_ENG_Version : 1.06

3) Condition for Running Diagnostic


Engine running
4) Condition for Setting the Fault Code
If Cumulative PRV opening counter exceeds 50,

5) Condition for Clearing the Fault Code


If Cumulative PRV opening counter is reset by service tool,

6) Check List
Standard
Step Inspection YES NO
Value
1 P0089 is occurred on service tool? Step 2

2 Park the machine in a safe area and Key OFF. Step 3


Key ON and Check PRV opening counter by service tool.
* Variable ; Erase the
3 50 Step 3
a) PRV opening counter (PRV_ctOpn_mp) Fault
Is the value greater than the standard value?
Replace Pressure relief valve and reset PRV opening
Problem Contact
4 timer by serviced tool.
Solved Help Desk
Is the fault code cleared?