EL AL STANDARDS LABORATORY
EL AL Head Office
Ben-Gurion Airport
Israel
Erez Lee Yadgar Phone: 972 3 9716596
Mobile: 972 54 4337757
CALIBRATION
In recognition of the successful completion of the A2LA evaluation process, accreditation is granted to this
laboratory to perform the following calibrations1, 5:
I. Dimensional
DC Power Supply –
Clamp – Meters
AC Voltage – Measuring
Equipment (Voltmeter)
AC Current – Measuring
Equipment (Ammeter)
Power Supply –
AC Current
AC Voltage – Measuring
Equipment (DMM)
AC Current – Measuring
Equipment (DMM)
(29 to 330) µA (10 to 20) Hz 0.2 µA/A + 0.1 µA Fluke 5522A multi –
(20 to 45) Hz 0.15 µA/A + 0.1 µA product calibrator
45 Hz to 1 kHz 0.13 µA/A + 0.1 µA
(1 to 5) kHz 0.3 µA/A + 0.15 µA
(5 to 10) kHz 0.8 µA/A + 0.2 µA
(10 to 30) kHz 1.6 µA/A + 0.4 µA
Resistance 50 Ω to 1 kΩ 0.6 Ω
(1 to 20) kΩ 5.8 Ω
III. Mechanical
Pressure3 –
Pressure Gages – (0 to 1000) psi 0.094 psi (0.6 kPa) Druck DPI 612
Hydraulic and (1000 to 5000) psi 0.26 psi (1.8 kPa)
Pneumatic (5000 to 10 000) psi 0.80 psi (5.5 kPa)
Torque, Torque Wrenches (0.056 to 0.113) N∙m 0.000 67 N∙m Torque transducers,
and Torque Drivers (0.113 to 0.565) N∙m 0.003 N∙m ISO 6789
(0.565 to 2.26) N∙m 0.0044 N∙m
(2.26 to 5.65) N∙m 0.0064 N∙m
(5.65 to 16.9) N∙m 0.036 N∙m
(16.9 to 28.2) N∙m 0.062 N∙m
(28.2 to 67) N∙m 0.092 N∙m
(67 to 340) N∙m 0.75 N∙m
(340 to 680) N∙m 1.4 N∙m
(680 to 880) N∙m 4.6 N∙m
(880 to 1320) N∙m 5.4 N∙m
IV. Thermodynamics
___________________________________________
1
This laboratory offers commercial calibration service.
2
Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMC’s
represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using
a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by
the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences
from the circumstances of the specific calibration.
3
Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA
Scope. Allowance must be made for aspects such as the environment at the place of calibration and for
other possible adverse effects such as those caused by transportation of the calibration equipment. The
usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must
also be considered and this, on its own, could result in the actual measurement uncertainty achievable on
a customer’s site being larger than the CMC
4
In the statement of CMC, percentages are to be read as percentage of reading, unless otherwise noted.
5
This lab meets A2LA’s P112 Flexible Scope Policy.
6
The type of instrument or material being calibrated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter.
EL AL STANDARDS LABORATORY
Tel Aviv, ISRAEL
for technical competence in the field of
Calibration
This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017
General requirements for the competence of testing and calibration laboratories. This laboratory also meets R205 – Specific
Requirements: Calibration Laboratory Accreditation Program. This accreditation demonstrates technical competence for a
defined scope and the operation of a laboratory quality management system
(refer to joint ISO-ILAC-IAF Communiqué dated April 2017).
_______________________
Vice President, Accreditation Services
For the Accreditation Council
Certificate Number 4282.01
Valid to July 31, 2023
For the calibrations to which this accreditation applies, please refer to the laboratory’s Calibration Scope of Accreditation.