05 ECPEN24-500A Sky Air
05 ECPEN24-500A Sky Air
05 ECPEN24-500A Sky Air
NEW
A update
Sky Air
Light commercial
applications
NEW Round flow cassette with UV Streamer kit
Pure air
because we care
Tested at Intertek
Results based on tests performed in
the laboratories of Intertek, in a 28m³ room.
99.9%
Daikin’s Round flow cassette (FXFQ125B)
removes more than 99.9% of enveloped
viruses such as Corona viruses.
of viruses removed in 30 minutes, * Additional details regarding this function can be found
388
INTRODUCTION
Sky Air the solution for the light
RESIDENTIAL
INDOOR AIR
commercial sector
QUALITY
Sky Air is Daikin’s industry-leading light commercial range, which has been designed for optimum
HEATING
seasonal energy efficiency. Providing the ideal solution for all kinds of small commercial spaces, the
Sky Air series offers a complete comfort solution that puts you in total control of your heating and
cooling, ventilation and air curtains.
SPLIT
SKY AIR
Sky Air
Light commercial
ROOFTOP
Wall mounted units 425
applications FAA-B425
FTXM-R428
Ceiling suspended units 429
NEW
combinations FHA-A(9)429
VRV
UNIQUE FUA-A433
Floor standing units 435
NEW
New Sky Air low height series 390 combinations FVA-A435
AIR PURIFICATION
VENTILATION &
Concealed floor standing units 438
COMMERCIAL
Low sound enclosure 391
FNA-A9438
Why choose a Daikin Sky Air 392
Biddle air curtains 440
In the spotlight 394
NEW Biddle air curtain for ERQ 441
INDUSTRY
MARINE
Outdoor units 443
Products overview indoor units 396
Products overview outdoor units 444
Benefits overview indoor units 398
Benefits overview outdoor units 445
Ceiling mounted cassettes 402
UV Streamer kit 402 Why choose 446
CHILLERS
NEW
UNIQUE FCAHG-H405 range 450
UNIQUE FCAG-B406
UNIQUE FFA-A9410 RZAG-A 450
Concealed ceiling units 414 RZAG-NV1/NY1 450
FAN COIL
RZASG-MV(1)/MY(1) 451
Multi zoning kit 415
FDXM-F9416 RZA-D 452
FBA-A(9)418
ARXM-R/
FDA125A422
AIR HANDLING
AZAS-MV/MY 453
FDA200-250A423
UNITS
389
Low height.
High value.
Unique, low-height
single fan range
easy to transport
870 mm
Market-leading
serviceability
and handling
390
INTRODUCTION
RESIDENTIAL
INDOOR AIR
QUALITY
HEATING
The smart way for
sound
SPLIT
reduction
SKY AIR
ROOFTOP
VRV
AIR PURIFICATION
VENTILATION &
COMMERCIAL
INDUSTRY
MARINE
– 10 dB(A)!
CHILLERS
Daikin dedicated solution for sound reduction
Meet strict sound requirements, while increasing flexiblity to apply Sky Air
and VRV heat pumps thanks to sound power reduction of up to 10 dB(A).
› Easy access: simple and fast installation and maintenance through large
UNITS
www.daikin.eu/en_us/products/ekln-a.html
CONTROL
SYSTEMS
391
7 reasons why Sky Air is
unique in
the market
1 Full Sky Air R-32 range delivering future-proofed,
best-in-class climate control
More details
on page 444
Product
System Type Model 35 50 60 71 100 125 140 200 250
name
3.5 kW 5.0 kW 6.0 kW 6.8 kW 9.5 kW 12.1 kW 13.4 kW 21.5 kW 23.6 kW
RZASG-
MV(1)/
Air Heat MY(1)
cooled pump - Technology and comfort combined for commercial applications
- Very compact and easy to install outdoor units (A+++ - D)
- Maximum piping length up to 50m (RZA-D up to 100m)
- Replacement technology
- Operation range down to -15°C both cooling and in heating (RZA-D down to -20°C) RZA-D
- Pair, twin, triple and double twin application
392
INTRODUCTION
RESIDENTIAL
INDOOR AIR
2 High energy efficiency 3 Best comfort
QUALITY
› Top seasonal efficiency › Variable Refrigerant Temperature preventing
› SEER up to 8.02 and A++ label in cooling and heating cold draughts
› Variable Refrigerant Temperature that automatically › Low sound indoor and outdoor units
HEATING
adapts the refrigerant temperature to the load › Presence and floor sensors direct the air flow away from
› Round flow and concealed ceiling units with auto persons, while ensuring an even temperature distribution
cleaning filter › Operation down to -20°C in heating and cooling
operation
NEW › UV Streamer kit, purifies the air of pollutants such as
viruses, bacteria, fine dust (PM1), odours, allergens, etc
SPLIT
› Fresh air intake integrated in indoor unit
SKY AIR
presence sensor
floor sensor
ROOFTOP
4 Top reliability 5 Market leading controls
› For infrastructure cooling › Remote connectivity
› unique boosted capacity indoor unit systems › Intuitive app control
› duty rotation control › Daikin Cloud Plus offering online control, energy
› Refrigerant cooled PCB monitoring and comparison of multiple sites
VRV
› New refrigerant passes keeping heat exchanger › User-friendly wired remote controller
and drain holes completely open at all times with premium design
› Most extensive testing before new units leave › Intuitive touch button control
AIR PURIFICATION
the factory › 3 color versions
VENTILATION &
COMMERCIAL
› Widest support network and after sales service › Advanced settings can be easily done
› All spare parts available in Europe via your smartphone
› Dedicated control solutions
› for retail applications
› for infrastructure cooling
INDUSTRY
MARINE
bottom plate refrigerant pass
CHILLERS
› Fully flat cassette design unit that integrates › 4-way blow ceiling suspended cassette (FUA)
fully flat into the ceiling for rooms without false ceiling.
› Auto cleaning units ensure dirt-free ceilings with high › Plug & play Daikin air handling unit with ERQ condensing
efficiency filters for regular and dust prone areas units
› Widest ever range cassette panels › Reliably replace Daikin and non-Daikin systems without
AIR HANDLING
› Available in white and black the need for pipe cleaning thanks to the new hepta filtration
UNITS
› Sleek designer panel range › Dedicated low sound enclosure, reducing sound power up
to -10 dB(A)
› Use up to 4 indoor units linked to one outdoor unit for
long or irregularly shaped rooms
REFRIGERATION
COMMERCIAL &
TRANSPORT
CONTROL
SYSTEMS
393
Always in control,
no matter where you are
LOCAL
CONTROL
More details
on page 944 Installer/
Customer technical manager
394
INTRODUCTION
RESIDENTIAL
INDOOR AIR
QUALITY
HEATING
Infrastructure
cooling
SPLIT
SKY AIR
Infrastructure cooling
ROOFTOP
› For rooms and enclosures that require round-the-clock cooling
› Where continuous uptime is the absolute requirement for server data protection Between
20-40%
sensible
capacity
VRV
increase
RELIABLE EFFICIENT FLEXIBLE
AIR PURIFICATION
Guaranteed system operation: Optimum return on investment: › Scalable in capacity
VENTILATION &
COMMERCIAL
› Oversized indoor units boost cooling › Lowers running costs by using › Improved infrastructure control
capacity and prevent freeze-ups on highly efficient direct expansion and management
the indoor side cooling systems › Lower physical footprint since
› Wide operating range envelope: opera- › Lower running costs compared to other no floor space is occupied
tion range in cooling down DX systems and water based chillers. › Wide range of indoor units to suit
to -20°C and up to +52°C › Reduces mechanical cooling and energy application preferences (ceiling
INDUSTRY
MARINE
consumption with the free cooling suspended cassettes, wall mounted
option for single phase systems indoors, concealed ceiling ducted
type indoors)
CHILLERS
Duty rotation application example
SYSTEM 1 FBA140 IN OPERATION SYSTEM 1 FBA140 STANDBY
SYSTEM 2 FBA140 STANDBY
FAN COIL
BRC1H* or BRC1E*
Standard includes duty
REFRIGERATION
COMMERCIAL &
TRANSPORT
rotation functionality
RZAG100
RZAG100
CONTROL
SYSTEMS
395
Indoor units
Product overview
Product
Type Model PG
name
Slimmest yet most powerfull medium static pressure unit on the market!
- Slimmest unit in class, only 245mm
Multi - Low operating sound level
Concealed ceiling unit
with medium ESP
zoning FBA-A(9) 418 - Medium external static pressure up to 150Pa facilitates using flexible ducts of
option varying lengths
- Automatic air flow adjustment function measures the air volume and static pressure
and adjusts it towards the nominal air flow, guaranteeing comfort
ESP up to 200Pa, ideal for large sized buildings
Concealed - Discretely concealed in the ceiling: only the grilles are visible
ceiling 422 - Possibility to change ESP via wired remote control allows optimisation of the supply
air volume
FDA125A - Flexible installation as the air suction direction can be altered from rear to bottom suction
Concealed ceiling unit with high ESP FDA-A
ESP up to 250Pa, Ideal for extra large sized spaces
- Discretely concealed in the ceiling: only the grilles are visible
423
- Possibility to change ESP via wired remote control allows optimisation of the supply
air volume
FDA200-250A
Ideal for residential applications with false ceilings
- Energy label up to A
Multi
Concealed ceiling unit ADEA-A 424 - Medium external static pressure up to 150Pa facilitates using flexible ducts of
zoning
varying lengths
option
- Slimmest unit in class, only 245mm
- Exclusively offered for pair applications
For rooms with no false ceilings nor free floor space
- Flat, stylish front panel
Wall mounted unit FAA-B 425 - The air is comfortably spread up- and downwards thanks to 5 different discharge angles
- Easy maintenance as this can be done from the front of the unit
Wall - Flexible to install: pipe connection can be bottom, left or right
mounted For rooms with no false ceilings nor free floor space
- Practically inaudible
Perfera wall mounted unit FTXM-R 428 - 2 area motion detection sensor
- Flash streamer technology
- 3D air flow
For wide rooms with no false ceilings nor free floor space
- Ideal for comfortable air flow in wide rooms thanks to Coanda effect
Ceiling suspended unit FHA-A(9) 429
- Even rooms with ceilings up to 3.8m can be heated up or cooled down very easily!
- Can be mounted in corners or narrow spaces without any problem
Ceiling
suspended Unique Daikin unit for high rooms with no false ceilings nor free floor space
- Even rooms with ceilings up to 3.5m can be heated up or cooled down very easily!
UNIQUE FUA-A 433 - Flexibility to suit every room layout without changing the location of the unit!
4-way blow ceiling suspended unit - Optimum comfort guaranteed with automatic air flow adjustment to the required load
- The air is comfortably spread up- and downwards thanks to 5 different discharge angles
For spaces with high ceilings
- Ideal solution for commercial spaces with no or narrow false ceilings
Floor standing unit FVA-A 435 - Even rooms with very high ceilings can be heated up or cooled down very easily!
- Guarantees a stable temperature
Floor - Vertical and horizontal outblow
standing
Designed to be concealed in walls, only grilles remain visible
- Slimmest unit on the market with a depth of only 200mm!
Concealed floor standing unit FNA-A9 438
- Both window sill or ducted installation are possible thanks to sufficient ESP
- Whisper quiet operation allows installation in any location
396
INTRODUCTION
Full R-32 Indoor units
FULL
line up single fan
RESIDENTIAL
INDOOR AIR
range
QUALITY
Outdoor unit combination
Capacity class
HEATING
RZAG- RZASG- AZAS-
RZAG-A RZA-D ARXM-R
NV1/NY1 MV(1)/MY(1) MV/MY
• • • •
SPLIT
• • • • • • •
SKY AIR
• • • •
• • • •
ROOFTOP
• • • • • • •
VRV
•
AIR PURIFICATION
VENTILATION &
COMMERCIAL
• •
• • •
INDUSTRY
MARINE
• •
• • • CHILLERS
NEW
• • • • • • •
FAN COIL
UNITS
• • •
AIR HANDLING
UNITS
NEW
• • • •
• • • •
REFRIGERATION
COMMERCIAL &
TRANSPORT
CONTROL
SYSTEMS
397
Indoor units
Benefit overview
Home leave Maintains the indoor temperature at your specified comfort level during absence, thus saving energy.
operation
Fan only The unit can be used as fan, blowing air without heating or cooling.
We care
The filter automatically cleans itself. Simplicity of upkeep means optimum energy efficiency and maximum comfort without
Auto cleaning filter
the need for expensive or time-consuming maintenance.
The presence sensor directs the air away from any person detected in the room, when the air flow control is on.
Presence & floor The floor sensor detects the average floor temperature and ensures an even temperature distribution between ceiling and
sensor
floor.
When starting to warm up or when the thermostat is off, the air discharge direction is set horizontally
Draught prevention
and the fan to low speed, to prevent draught. After warming up, air discharge and fan speed are set as desired.
Comfort
Daikin indoor units are whisper quiet. Also the outdoor units are guaranteed
Whisper quiet
not to disturb the quiet of the neightbourhood.
Auto cooling- Automatically selects cooling or heating mode to achieve the set temperature.
heating changeover
NEW Purifies the air of pollutants such as viruses, bacteria, fine dust, odours, allergens, etc ensuring a healthy and hygienic indoor
UV Streamer kit environment
Air treatment
Air filter Removes airborne dust particles to ensure a steady supply of clean air.
Humidity
control
Dry programme Allows humidity levels to be reduced without variations in room temperature.
Ceiling soiling Prevents air from blowing out too long in horizontal position, to prevent ceiling stains.
prevention
Vertical auto swing Possibility to select automatic vertical moving of the air discharge louvre, for uniform air flow and temperature distribution.
Air flow
Fan speed steps Allows to select up to the given number of fan speed.
Individual flap Individual flap control via the wired remote controller enables you to easily fix the position of each flap individually,
control to suit any new room configuration. Optional closure kits are available as well.
Onecta app Control your indoor climate from any location via smartphone or tablet.
Remote control & timer
Weekly timer Can be set to start heating or cooling anytime on a daily or weekly basis.
Infrared remote Starts, stops and regulates the air conditioner from a distance.
control
Wired remote Starts, stops and regulates the air conditioner.
control
Centralised control Starts, stops and regulates several air conditioners from one central point.
Multi zoning Allows up to 6 individual climate zones with one indoor unit
Infrastructure Remove in a reliable, efficient and flexible way the heat constantly generated by the IT and server equipment to ensure
cooling maximum uptime while offering the best return on investment.
Auto-restart The unit restarts automatically at the original settings after power failure.
Drain pump kit Facilitates condensation draining from the indoor unit.
Twin/triple/double 2, 3 or 4 indoor units can be connected to only a single outdoor unit even if they have different capacities. All indoor units
twin application operate within the same heating or cooling mode from one remote control.
Multi model Up to 5 indoor units can be connected to a single outdoor unit, even if they have different capacities. All indoor units can
application individually be operated within the same heating or cooling mode.
VRV for residential Up to 9 indoor units (even different capacities and up to 71 class) can be connected to a single outdoor unit.
application All indoor units can individually be operated within the same mode.
398
INTRODUCTION
Indoor units
4-Way blow
Ceiling mounted Ceiling Wall Perfera wall Floor
Concealed ceiling ceiling
cassette suspended mounted mounted standing
units suspended
units units unit unit units
RESIDENTIAL
unit
INDOOR AIR
QUALITY
F C A HG - H FC AG -B FFA-A9 FDXM - F9 FB A- A(9) FDA125A FDA2 00- 250A A DE A - A F H A - A ( 9) FUA-A FAA-B F T XM - R FVA-A F NA - A 9
HEATING
• • • • • • • • • • • • •
• • • • • • • • • • • • • •
• • •
SPLIT
• • •
• • • •
SKY AIR
• • • • • •
• • • • • • • • • • • • • •
ROOFTOP
• •
• •
(Optional high
efficiency filter • • • • • • • • • • (Flash streamer;
titanium apatite
deodorising
• •
ePM10 60%) filter)
VRV
• • • • • • • • • • • • • •
AIR PURIFICATION
VENTILATION &
COMMERCIAL
• • •
• • • • • • •
(incl. 3D •
air flow)
INDUSTRY
5 + auto 5 + auto 3 + auto 3 3 + auto 9 + auto 3 + auto 3 + auto 5 + auto 3 + auto 3 + auto 5 + auto 3 + auto 3 + auto
MARINE
• • • •
• • • • • • • • • • • • • •
CHILLERS
• • • • • • • • • • • • • •
• • • • • • • • • • • • •
• • • • • • • • • • • • • •
FAN COIL
• • • • • • • • • • • • • •
UNITS
• • •
AIR HANDLING
• • • • • • • • • • • • •
UNITS
• • • • • • • • • • • • • •
• • • • • • • • • • • • • •
• • • • • • • • • •
REFRIGERATION
COMMERCIAL &
TRANSPORT
• • • • • • • • • • •
• • • • • •
• • • • • •
CONTROL
SYSTEMS
• standard, • optional
399
Sky Air
400
WALL MOUNTED UNIT
401
COMMERCIAL & COMMERCIAL RESIDENTIAL
CONTROL AIR HANDLING FAN COIL MARINE
TRANSPORT CHILLERS VENTILATION & VRV ROOFTOP SKY AIR SPLIT HEATING INDOOR AIR INTRODUCTION
SYSTEMS UNITS UNITS INDUSTRY
REFRIGERATION AIR PURIFICATION QUALITY
NEW Round flow cassette with UV Streamer kit
Pure air
because we care
Tested at Intertek
Results based on tests performed in
the laboratories of Intertek, in a 28m³ room.
99.9%
Daikin’s Round flow cassette (FXFQ125B)
removes more than 99.9% of enveloped
viruses such as Corona viruses.
of viruses removed in 30 minutes, * Additional details regarding this function can be found
402
INTRODUCTION
RESIDENTIAL
INDOOR AIR
QUALITY
Daikin’s unique Catch & Clean approach includes an
HEATING
ePM1 50% filter, UV-C light and Streamer technology
SPLIT
2 Effective cleaning and decomposition
of pollutants
1 Effective capturing of air
Our unique combined UV-C light and
borne pollutants
› Highly efficient capturing Streamer technology ensures both
particulate matter and surface and in-depth sanitising of the
filter to ensure hygienic air.
SKY AIR
pollutants thanks to
the ISO ePM1 60% (F7) filter
› Anti bacterial and viral UVC LED light with high output
coating wavelength of 265nm which is
the most effective for surface cleaning
and inactivation of bacteria and viruses.
ROOFTOP
Indicator light
Indicates operation,
malfunction or replacement status
VRV
AIR PURIFICATION
VENTILATION &
COMMERCIAL
Streamer technology for deep
sanitising of the filter and powerful
decomposition of viruses and
bacteria trapped inside the filter.
INDUSTRY
MARINE
CHILLERS
Specifications
FAN COIL
BAEF125AWB
UNITS
(UV-streamer kit cannot be used with other filters, chambers, fresh air intake kits or air discharge outlet sealing member kit)
UNITS
* For compatibility with older panels, consult your local sales representative
COMMERCIAL &
TRANSPORT
download
the leaflet here
CONTROL
SYSTEMS
403
Complete indoor
comfort, including
pure air
The round flow cassette
› Maximum comfort thanks to 360° air discharge and intelligent sensors
Black auto cleaning panel Black designer panel Full white standard panel White designer panel
› Auto cleaning panel keeps the filter free of dust for maximum efficiency
› UV streamer kit
NEW › Purifies the air of pollutants such as viruses, bacteria, fine dust PM1, odours, allergens, etc ensur-
ing a healthy and hygienic indoor environment
› Unique catch & clean approach includes an ISO ePM1 60% (F7) filter, UV-C light
and Streamer technology
› Can be retrofitted into existing installations
Tested at Intertek
Results based on tests performed in
the laboratories of Intertek, in a 28m³ room.
99.9%
Daikin’s Round flow cassette (FXFQ125B)
removes more than 99.9% of enveloped
viruses such as Corona viruses.
of viruses removed in 30 minutes, * Additional details regarding this function can be found
404
INTRODUCTION
FCAHG-H + RZAG-NV1 / NY1
RESIDENTIAL
INDOOR AIR
QUALITY
360° air discharge for optimum efficiency and comfort
HEATING
› High COP cassette ensures top performance and great energy savings
› Optional automatic filter cleaning panel results in higher efficiency
& comfort and lower maintenance costs.
› Individual flap control: flexibility to suit every room layout without FCAHG-H
changing the location of the unit!
› Widest choice ever in decoration panels: designer panels in white
SPLIT
(RAL9010) and black (RAL9005) and standard panels in white
(RAL9010) with grey louvers or full white
› Bigger flaps and unique swing pattern improve equal air distribution
› 5 different fan speeds available for maximum comfort
› UV streamer kit, purifies the air of pollutants such as viruses,
SKY AIR
bacteria, fine dust, odours, allergens, etc ensuring a healthy and RZAG-NV1_NY1 BRC1H52W BRP069C82
hygenic indoor environment
› Optional fresh air intake
› Branch duct discharge allows to optimize air distribution in
irregular shaped rooms or to supply air to small adjacent rooms
ROOFTOP
› Standard drain pump with 675mm lift increases flexibility and
installation speed
White panel White auto cleaning panel Black panel Black design panel
VRV
Efficiency data FCAHG + RZAG 71H + 71NV1 100H + 100NV1 125H + 125NV1 140H + 140NV1 71H + 71NY1 100H + 100NY1 125H + 125NY1 140H + 140NY1
Cooling capacity Nom. kW 6.80 9.50 12.1 13.4 6.80 9.50 12.1 13.4
Heating capacity Nom. kW 7.50 10.8 13.5 15.5 7.50 10.8 13.5 15.5
Space cooling Energy efficiency class A++ - A++ -
AIR PURIFICATION
VENTILATION &
Capacity Pdesign kW 6.80 9.50 12.1 13.4 6.80 9.50 12.1 13.4
COMMERCIAL
SEER 7.90 7.70 8.02 7.93 7.90 7.70 8.02 7.93
ηs,c % - 318 314 - 318 314
Annual energy consumption kWh/a 301 432 905 1,014 301 432 905 1,014
Space heating Energy efficiency class A++ - A+ A++ -
(Average climate) Capacity Pdesign kW 4.70 9.52 4.70 9.52
SCOP/A 4.61 4.75 4.53 4.44 4.56 4.75 4.53 4.44
ηs,h % - 178 175 - 178 175
Annual energy consumption kWh/a 1,427 2,805 2,943 3,002 1,443 2,805 2,943 3,002
INDUSTRY
MARINE
Indoor unit FCAHG 71H 100H 125H 140H 71H 100H 125H 140H
Dimensions Unit HeightxWidthxDepth mm 288x840x840
Weight Unit kg 25.0
Air filter Type Resin net
Decoration panel Model Standard panels: BYCQ140E - white with grey louvers / BYCQ140EW - full white / BYCQ140EB - black
Auto cleaning panels: BYCQ140EGF - white / BYCQ140EGFB - black
Designer panels: BYCQ140EP - white / BYCQ140EPB - black
CHILLERS
Dimensions HeightxWidthxDepth mm Standard panels: 65x950x950 / Auto cleaning panels: 148x950x950 / Designer panels: 106x950x950
Weight kg Standard panels: 5.5 / Auto cleaning panels: 10.3 / Designer panels: 6.5
Fan Air flow Cooling Low/Medium/High m³/min 13.7/18.8/23.6 19.1/25.7/32.2 21.2/27.3/34.4 13.7/18.8/23.6 19.1/25.7/32.2 21.2/27.3/34.4
rate Heating Low/Medium/High m³/min 13.7/18.8/23.6 18.3/24.6/30.8 19.7/25.5/32.1 13.7/18.8/23.6 18.3/24.6/30.8 19.7/25.5/32.1
Sound power level Cooling dBA 53.0 61.0 53.0 61.0
Heating dBA 53.0 61.0 53.0 61.0
Sound pressure Cooling Low/High dBA 29.0/36.0 33.0/44.0 35.0/45.0 37.0/45.0 29.0/36.0 33.0/44.0 35.0/45.0 37.0/45.0
level Heating Low/High dBA 29.0/36.0 33.0/44.0 35.0/45.0 37.0/45.0 29.0/36.0 33.0/44.0 35.0/45.0 37.0/45.0
FAN COIL
UNITS
Weight Unit kg 81 85 95 81 85 94
Sound power level Cooling dBA 64 66 69 70 64 66 69 70
UNITS
Heating dBA - 68 71 - 68 71
Sound pressure Cooling Nom. dBA 46 47 49 50 46 47 49 50
level Heating Nom. dBA 48 50 52 48 50 52
Operation range Cooling Ambient Min.~Max. °CDB -20~52
Heating Ambient Min.~Max. °CWB -20~18
REFRIGERATION
COMMERCIAL &
RESIDENTIAL
INDOOR AIR
QUALITY
360° air discharge for optimum efficiency and comfort
HEATING
› Optional automatic filter cleaning panel results in higher efficiency
& comfort and lower maintenance costs.
› Two optional intelligent sensors improve energy efficiency and
comfort FCAG-B
› Widest choice ever in decoration panels: designer panels in white
(RAL9010) and black (RAL9005) and standard panels in white
SPLIT
(RAL9010) with grey louvers or full white
› Bigger flaps and unique swing pattern improve equal air distribution
› Individual flap control: flexibility to suit every room layout without
changing the location of the unit!
› UV streamer kit, purifies the air of pollutants such as viruses,
SKY AIR
bacteria, fine dust, odours, allergens, etc ensuring a healthy and RZASG100-140MV(1)/MY(1) BRC1H52W, BRP069C82
hygenic indoor environment
› Optional fresh air intake
› Branch duct discharge allows to optimize air distribution in
irregular shaped rooms or to supply air to small adjacent rooms
ROOFTOP
› Standard drain pump with 675mm lift increases flexibility and
installation speed
White panel White auto cleaning panel Black panel Black design panel
More details and final
information can be
found by scanning or
clicking the QR codes. FCAG-B RZASG-MV1 RZASG-MY1 RZASG-MV RZASG-MY
VRV
Efficiency data FCAG + RZASG 71B + 71MV1 100B + 100MV(1) 125B + 125MV(1) 140B + 140MV(1) 100B + 100MY(1) 125B + 125MY(1) 140B + 140MY(1)
Cooling capacity Nom. kW 6.80 9.50 12.1 13.4 9.50 12.1 13.4
Heating capacity Nom. kW 7.50 10.8 13.5 15.5 10.8 13.5 15.5
Space cooling Energy efficiency class A++ - A++ -
AIR PURIFICATION
VENTILATION &
Capacity Pdesign kW 6.80 9.50 12.1 13.4 9.50 12.1 13.4
COMMERCIAL
SEER 6.47 6.55 5.76 6.53 6.55 5.76 6.53
ηs,c % - 227 258 - 227 258
Annual energy consumption kWh/a 368 507 1,261 1,231 507 1,261 1,231
Space heating Energy efficiency class A+ - A+ -
(Average climate) Capacity Pdesign kW 4.50 6.00 7.80 6.00 7.80
SCOP/A 4.10 4.17 4.05 4.31 4.17 4.05 4.31
ηs,h % - 159 169 - 159 169
Annual energy consumption kWh/a 1,537 2,016 2,074 2,534 2,016 2,074 2,534
INDUSTRY
MARINE
Indoor unit FCAG 71B 100B 125B 140B 100B 125B 140B
Dimensions Unit HeightxWidthxDepth mm 204x840x840 246x840x840
Weight Unit kg 21 23
Air filter Type Resin net
Decoration panel Model Standard panels: BYCQ140E - white with grey louvers / BYCQ140EW - full white / BYCQ140EB - black
Auto cleaning panels: BYCQ140EGF - white / BYCQ140EGFB - black
Designer panels: BYCQ140EP - white / BYCQ140EPB - black
CHILLERS
Dimensions HeightxWidthxDepth mm Standard panels: 65x950x950 / Auto cleaning panels: 148x950x950 / Designer panels: 106x950x950
Weight kg Standard panels: 5.5 / Auto cleaning panels: 10.3 / Designer panels: 6.5
Fan Air flow Cooling Low/Medium/High m³/min 10.8/13.0/15.1 13.0/17.8/22.7 13.1/20.4/27.2 13.0/17.8/22.7 13.1/20.4/27.2
rate Heating Low/Medium/High m³/min 10.8/12.9/15.1 13.2/18.1/23.0 13.0/20.2/27.0 13.2/18.1/23.0 13.0/20.2/27.0
Sound power level Cooling dBA 51.0 54.0 58.0 54.0 58.0
Heating dBA 51.0 54.0 58.0 54.0 58.0
Sound pressure Cooling Low/Medium/High dBA 28.0/31.0/35.0 29.0/33.0/37.0 29.0/35.0/41.0 29.0/33.0/37.0 29.0/35.0/41.0
level Heating Low/Medium/High dBA 28.0/31.0/33.0 29.0/33.0/37.0 29.0/35.0/41.0 29.0/33.0/37.0 29.0/35.0/41.0
FAN COIL
UNITS
Weight Unit kg 60 70 (MV1) / 72 (MV) 78 (MV1) / 79 (MV) 70 (MY1) / 72 (MY) 78 (MV1) / 79 (MV)
Sound power level Cooling dBA 65 70 71 73 70 71 73
UNITS
Heating dBA - 71 73 - 71 73
Sound pressure Cooling Nom. dBA 46 53 54 53 54
level Heating Nom. dBA 47 57
Operation range Cooling Ambient Min.~Max. °CDB -15~46
Heating Ambient Min.~Max. °CWB -15~15.5
Refrigerant Type/GWP R-32/675
REFRIGERATION
COMMERCIAL &
TRANSPORT
RESIDENTIAL
INDOOR AIR
QUALITY
360° air discharge for optimum efficiency and comfort
HEATING
› Optional automatic filter cleaning panel results in higher efficiency
& comfort and lower maintenance costs.
› Two optional intelligent sensors improve energy efficiency and
comfort FCAG-B
› Widest choice ever in decoration panels: designer panels in white
(RAL9010) and black (RAL9005) and standard panels in white
SPLIT
(RAL9010) with grey louvers or full white
› Bigger flaps and unique swing pattern improve equal air
distribution
› Individual flap control: flexibility to suit every room layout without
changing the location of the unit!
SKY AIR
› UV streamer kit, purifies the air of pollutants such as viruses, RXM-R BRC1H52W BRP069C82
bacteria, fine dust, odours, allergens, etc ensuring a healthy and
hygenic indoor environment
› Optional fresh air intake
› Branch duct discharge allows to optimize air distribution in
ROOFTOP
irregular shaped rooms or to supply air to small adjacent rooms
› Standard drain pump with 675mm lift increases flexibility and
installation speed White panel White auto cleaning panel Black panel Black design panel
VRV
Efficiency data FCAG + RXM 35B + 35R9 50B + 50A 60B + 60R
Cooling capacity Nom. kW 3.50 5.00 5.70
Heating capacity Nom. kW 4.20 6.00 7.00
Space cooling Energy efficiency class A++ A++
AIR PURIFICATION
VENTILATION &
Capacity Pdesign kW 3.50 5.00 5.70
COMMERCIAL
SEER 6.35 6.54 6.40
Annual energy consumption kWh/a 193 268 312
Space heating Energy efficiency class A++ A+
(Average climate) Capacity Pdesign kW 3.32 4.36 4.71
SCOP/A 4.90 4.30 4.20
Annual energy consumption kWh/a 948 1,418 1,569
Indoor unit FCAG 35B 50B 60B
INDUSTRY
MARINE
Dimensions Unit HeightxWidthxDepth mm 204x840x840
Weight Unit kg 18 19
Air filter Type Resin net
Decoration panel Model Standard panels: BYCQ140E - white with grey louvers / BYCQ140EW - full white / BYCQ140EB - black
Auto cleaning panels: BYCQ140EGF - white / BYCQ140EGFB - black
Designer panels: BYCQ140EP - white / BYCQ140EPB - black
Dimensions HeightxWidthxDepth mm Standard panels: 65x950x950 / Auto cleaning panels: 148x950x950 / Designer panels: 106x950x950
CHILLERS
Weight kg Standard panels: 5.5 / Auto cleaning panels: 10.3 / Designer panels: 6.5
Fan Air flow Cooling Low/Medium/High m³/min 8.8/10.6/12.9 9.4/11.8/14.6 9.6/12.2/14.9
rate Heating Low/Medium/High m³/min 9.4/11.6/14.1 9.4/11.8/14.6 9.6/12.2/14.9
Sound power level Cooling dBA 49.0 49.0 51.0
Heating dBA 49.0 49.0 51.0
Sound pressure Cooling Low/Medium/High dBA 27.0/29.0/31.0 28.0/31.0/33.0
level Heating Low/Medium/High dBA 27.0/29.0/31.0 28.0/31.0/33.0
FAN COIL
410
INTRODUCTION
RESIDENTIAL
INDOOR AIR
QUALITY
HEATING
Unique design
› Designed by a European design office to fully › Fully integrated in the one ceiling tile, enabling
meet the European taste. lights, speakers and sprinklers to be installed in
› Fully flat into the ceiling, leaving only 8mm. adjoining ceiling tiles.
SPLIT
› Decoration panel available in 2 colours
(white and white-silver).
SKY AIR
ROOFTOP
Differentiating in technology
VRV
Optional presence sensor Optional floor sensor
› When the room is empty, it can adjust the set › Detects the temperature difference and
temperature or switch off the unit – saving re-directs the airflow to ensure even
AIR PURIFICATION
energy. temperature distribution.
VENTILATION &
COMMERCIAL
› When people are detected, the direction of
the airflow is adapted to avoid cold draughts
being directed towards occupants.
INDUSTRY
MARINE
CHILLERS
*
› Seasonal efficiency labels up to › Individual flap control: easily control one or more
› When the room is empty, the sensor option can flaps via the wired remote controller (BRC1E/
adjust the set temperature or switch off the unit BRC1H) when rearranging the room. When fully
– saving up to 27% energy. closing or blocking the flaps, the option “Sealing
AIR HANDLING
* for FFA25,35A9 in combination with RXM25,35 › Most silent cassette in the market (25dBA),
important for office applications.
REFRIGERATION
COMMERCIAL &
TRANSPORT
Marketing tools
› https://www.daikin.eu/en_us/product-group/fully-flat-cassette.html
› www.youtube.com/DaikinEurope
CONTROL
SYSTEMS
411
FFA-A9 + RZAG-A
412
INTRODUCTION
FFA-A9 + RXM-R(9)/A Split
RESIDENTIAL
INDOOR AIR
QUALITY
Unique design in the market that
integrates fully flat into the ceiling
HEATING
offices and residential applications
› Fully flat integration in standard architectural ceiling tiles, leaving
only 8mm
› Remarkable blend of iconic design and engineering excellence with FFA-A9
an elegant finish in white or a combination of silver and white
› Unified indoor unit range for R-32 and R-410A
SPLIT
› Two optional intelligent sensors improve energy efficiency and
comfort
› Individual flap control: flexibility to suit every room layout without
changing the location of the unit!
› Optional fresh air intake
SKY AIR
› Branch duct discharge allows to optimize air distribution in RXM-R BRC1H52W BRP069C81
irregular shaped rooms or to supply air to small adjacent rooms
› Standard drain pump with 630mm lift increases flexibility and
installation speed
ROOFTOP
More details and final information
can be found by scanning or
clicking the QR codes. FFA-A9 RXM-R RXM-R9 RXM-A
Efficiency data FFA + RXM 25A9 + 25R9 35A9 + 35R9 50A9 + 50A 60A9 + 60R
Cooling capacity Nom. kW 2.50 3.40 5.00 5.70
Heating capacity Nom. kW 3.20 4.20 5.80 7.00
Power input Cooling Nom. kW 0.55 0.89 1.54 1.86
VRV
Heating Nom. kW 0.82 1.20 1.66 2.05
Space cooling Energy efficiency class A++ A+
Capacity Pdesign kW 2.50 3.40 5.00 5.70
SEER 6.17 6.38 5.98 5.76
Annual energy consumption kWh/a 142 186 293 346
AIR PURIFICATION
VENTILATION &
COMMERCIAL
Space heating Energy efficiency class A+ A A+
(Average climate) Capacity Pdesign kW 2.31 3.10 3.84 3.96
SCOP/A 4.24 4.10 3.90 4.04
Annual energy consumption kWh/a 762 1,058 1,378 1,373
Nominal efficiency EER 4.57 3.81 3.24 3.05
COP 3.90 3.50 3.49 3.41
Annual energy consumption kWh 273 446 772 931
Energy labeling Directive Cooling/Heating A/A A/B B/B
INDUSTRY
MARINE
Indoor unit FFA 25A9 35A9 50A9 60A9
Dimensions Unit HeightxWidthxDepth mm 260x575x575
Weight Unit kg 16.0 17.5
Air filter Type Resin net
Decoration panel Model BYFQ60C2W1W / BYFQ60C2W1S / BYFQ60B2W1 / BYFQ60B3W1
Colour White (N9.5)/SILVER/White (RAL9010)/WHITE (RAL9010)
Dimensions HeightxWidthxDepth mm 46x620x620 / 46x620x620 / 55x700x700 / 55x700x700
CHILLERS
Weight kg 2.8/2.8/2.7/2.7
Fan Air flow Cooling Low/Medium/High m³/min 6.5/8.0/9.0 6.5/8.5/10.0 8.6/10.9/12.7 9.5/12.5/14.5
rate Heating Low/Medium/High m³/min 6.5/8.0/9.0 6.5/8.5/10.0 8.6/10.9/12.7 9.5/12.5/14.5
Sound power level Cooling dBA 48.0 51.0 56.0 60.0
Sound pressure Cooling Low/Medium/High dBA 25.0/28.5/31.0 25.0/30.5/34.0 27.0/34.0/39.0 32.0/40.0/43.0
level Heating Low/Medium/High dBA 25.0/28.5/31.0 25.0/30.5/34.0 27.0/34.0/39.0 32.0/40.0/43.0
Control systems Infrared remote control BRC7EB530W (standard panel) / BRC7F530W (white panel) / BRC7F530S (grey panel)
FAN COIL
413
Auto cleaning filter
for concealed ceiling units
0%
start 6 months 12 months
414
INTRODUCTION
Multi zoning kit
RESIDENTIAL
INDOOR AIR
QUALITY
for concealed ceiling units
HEATING
Easy selection
via our NEW
The multi-zoning system is a room-by-room controller. It is fitted with motorised dampers, which immediately software!
SPLIT
adapt using Daikin ducted solutions. This system supports control of up to 8 zones via a centralised thermostat
located in the main room and individual thermostats for each of the zones.
SKY AIR
Increased comfort 20°C
› Increases comfort levels by allowing more 19°C
individual zone control
- Up to 8 individual zones can be served thanks
to separate modulating dampers Zoning box:
fully pre-assembled
ROOFTOP
- Individual thermostat for room-by-room or 21°C plenum with
zone-by-zone control dampers
VRV
› Color graphic interface for low-energy e-ink screen for controlling the temperature
units and system controls controlling zones controlling zones
› Time saving as plenum comes fully pre-assembled
with dampers, and control boards
AIR PURIFICATION
› Reduces the amount of refrigerant required in the
VENTILATION &
COMMERCIAL
installation
AZCE6BLUEZEROCB (Wired) AZCE6THINKRB (Wireless) AZCE6LITECB (Wired)
AZCE6LITERB (Wireless)
Compatibility
FDXM-F9 FBA-A(9) ADEA-A FXDQ-A3 FXSQ-A
INDUSTRY
Ø
MARINE
Number of Dimensions
Reference 25 35 50 60 35 50 60 71 100 125 140 71 100 125 15 20 25 32 40 50 63 15 20 25 32 40 50 63 80 100 125 140
motorised dampers H x W x D (mm) (mm)
2
AZEZ6DAIST07XS2 • • • •
AZEZ6DAIST07S2
300 x 930 x 454
• • • •
3
AZEZ6DAIST07XS3 • • • •
AZEZ6DAIST07S3 • • • •
4
AZEZ6DAIST07S4
300 x 1,140 x 454
• • • •
AZEZ6DAIST07M4 • • • • •
CHILLERS
Standard plenum AZEZ6DAIST07M5 • • • • •
5 300 x 1,425 x 454 200
AZEZ6DAIST07L5 • • • • • • •
6
AZEZ6DAIST07M6
300 x 1,638 x 454
• • • • •
AZEZ6DAIST07L6 • • • • • • •
7
AZEZ6DAIST07L7 • • • • • • •
AZEZ6DAIST07XL7
515 x 1,425 x 454
•
AZEZ6DAIST07L8 • • • • • • •
FAN COIL
8
•
UNITS
AZEZ6DAIST07XL8
2
AZEZ6DAIBS07XS2 • • • •
AZEZ6DAIBS07S2 • • • •
AZEZ6DAIBS07XS3 250 x 930 x 454 • • • •
3 AZEZ6DAIBS07S3 • • • •
AZEZ6DAIBS07M3 • • • • •
AIR HANDLING
AZEZ6DAIBS07S4 • • • •
• • • • •
UNITS
• • • • •
TRANSPORT
AZEZ6DAIBS07M6
6 AZEZ6DAIBS07L6 250 x 1,638 x 454 • • • • • • •
AZEZ6DAIBS07XL6 •
Slim plenum 2 AZEZ6DAISL01S2
210 x 720 x 444
• • • • • •
3 AZEZ6DAISL01S3
200
• • • • • •
4 AZEZ6DAISL01M4 210 x 930 x 444 • •
5 AZEZ6DAISL01L5 210 x 1,140 x 444 • • •
(1) Reversible units can be blocked to heating only via AZX6MCS module
CONTROL
SYSTEMS
416
INTRODUCTION
FDXM-F9 + RXM-R(9)/A Split
RESIDENTIAL
INDOOR AIR
QUALITY
Compact concealed ceiling unit, with
a height of only 200mm
HEATING
offices and residential applications
› Invisible unit as the unit is concealed in the ceiling: only the
suction and discharge grilles are visible
› Compact dimensions, can easily be mounted in a ceiling void of FDXM25-35F9
only 240mm
› Medium external static pressure up to 40Pa facilitates unit use
SPLIT
with flexible ducts of varying lengths
› Auto cleaning filter option ensures maximum efficiency, comfort
and reliability by regular filter cleaning
› Multi zoning kit allows multiple individually-controlled
climate zones to be served by one indoor unit
SKY AIR
› Onecta app (optional): control your indoor from with auto RXM-R BRC1H52W BRP069C81
any location with an app, via your local network or cleaning and
internet. multi zoning
option
ROOFTOP
More details and final information
can be found by scanning or
VRV
clicking the QR codes. FDXM-F9 RXM-R RXM-R9 RXM-A
Efficiency data FDXM + RXM 25F9 + 25R9 35F9 + 35R9 50F9 + 50A 60F9 + 60R
Cooling capacity Nom. kW 1.30/2.40/3.00 1.40/3.40/3.80 1.70/5.00/5.30 1.70/6.00/6.50
AIR PURIFICATION
Heating capacity Nom./Max. kW 1.30/3.20/4.50 1.40/4.00/5.00 1.70/5.80/6.00 1.70/7.00/7.10
VENTILATION &
COMMERCIAL
Space cooling Energy efficiency class A+ A A+ A
Capacity Pdesign kW 2.40 3.40 5.00 6.00
SEER 5.68 5.26 5.77 5.56
Annual energy consumption kWh/a 148 226 303 378
Space heating Energy efficiency class A+ A A
(Average climate) Capacity Pdesign kW 2.60 2.90 4.00 4.60
SCOP/A 4.24 3.88 3.93 3.80
INDUSTRY
MARINE
Annual energy consumption kWh/a 858 1,046 1,424 1,693
Indoor unit FDXM 25F9 35F9 50F9 60F9
Dimensions Unit HeightxWidthxDepth mm 200x750x620 200x1,150x620
Weight Unit kg 21 28
Air filter Type Removable/washable
Fan Air flow Cooling Low/Medium/High m³/min 7.3/8.0/8.7 13.3/14.6/15.8 13.5/14.8/16.0
CHILLERS
rate Heating Low/Medium/High m³/min 7.3/8.0/8.7 13.3/14.6/15.8 13.5/14.8/16.0
External static Nom. Pa 30 40
pressure
Sound power level Cooling dBA 53.0 55.0 56.0
Heating dBA 53.0 55.0 56.0
Sound pressure Cooling Low/High dBA 27.0/35.0 30.0/38.0
level Heating Low/High dBA 27.0/35.0 30.0/38.0
FAN COIL
UNITS
NEW
Outdoor unit RXM 25R9 35R9 50A 60R
Dimensions Unit HeightxWidthxDepth mm 552x840x350 734x954x401
Weight Unit kg 32 49.0
Sound pressure Cooling Nom. dBA 46.0 49.0 48.0
AIR HANDLING
417
FBA-A(9) + RZAG-A / NV1 / NY1
418
INTRODUCTION
FBA-A(9) + RZASG-MV(1)/MY(1)
RESIDENTIAL
INDOOR AIR
QUALITY
with medium ESP
Slimmest yet most powerful medium
outblow
static pressure unit on the market
HEATING
rear
› Combination with Sky Air Advance-series ensures good value for suction
bottom
money for all types of commercial applications suction
› Slimmest unit in class, only 245mm (300mm built-in height) and FBA100-140A(9)
therefore narrow ceiling voids are no longer a challenge
› Low operation sound level down to 25dBA
SPLIT
› Medium external static pressure up to 150Pa facilitates using
flexible ducts of varying lengths
› Possibility to change ESP via wired remote control allows
optimisation of the supply air volume
SKY AIR
RZASG100-140MV(1)/MY(1) BRC1H52W BRP069C81 with
Optimised supply air volume External static pressure (Pa)
multi zoning
Automatically selects the most appropriate fan curve
to achieve the units’ nominal air flow within ±10% Fan characteristic
Air flow (rated) More details and final information can be option
curves
found by scanning or clicking the QR codes.
Why? Air flow (actual)
After installation the real ducting will frequently
ROOFTOP
differ from the initially calculated air flow resistance
the real air flow may be much lower or higher
than nominal, leading to a lack of capacity or
Air flow (with
FBA-A(9) RZASG-MV1 RZASG-MY1
uncomfortable air temperature. Automatic Airflow Duct resistance
automatic adjustment)
Adjustment function will adapt the unit’s fan speed curves
to any ducting automatically (10 or more fan curves
are available on every model), making installation
much faster ±10% Air flow (m3/min)
RZASG-MV RZASG-MY
VRV
Efficiency data FBA + RZASG 71A9 + 71MV1 100A + 100MV(1) 125A + 125MV(1) 140A + 140MV(1) 100A + 100MY(1) 125A + 125MY(1) 140A + 140MY(1)
Cooling capacity Nom. kW 6.80 9.50 12.1 13.4 9.50 12.1 13.4
Heating capacity Nom. kW 7.50 10.8 13.5 15.5 10.8 13.5 15.5
Space cooling Energy efficiency class A++ A+ - A+ -
AIR PURIFICATION
VENTILATION &
Capacity Pdesign kW 6.80 9.50 12.1 13.4 9.50 12.1 13.4
COMMERCIAL
SEER 6.19 5.83 5.49 5.81 5.83 5.49 5.81
ηs,c % - 217 229 - 217 229
Annual energy consumption kWh/a 385 570 1,322 1,384 570 1,322 1,384
Space heating Energy efficiency class A+ A - A -
(Average climate) Capacity Pdesign kW 4.50 6.00 7.80 6.00 7.80
SCOP/A 4.01 3.85 3.63 3.85 3.63 3.85
ηs,h % - 142 151 - 142 151
INDUSTRY
MARINE
Annual energy consumption kWh/a 1,571 2,182 2,314 2,836 2,182 2,314 2,836
Indoor unit FBA 71A9 100A 125A 140A 100A 125A 140A
Dimensions Unit HeightxWidthxDepth mm 245x1,000x800 245x1,400x800
Weight Unit kg 35.0 46.0
Air filter Type Resin net
Fan Air flow Cooling Low/Medium/High m³/min 12.5/15.0/18.0 20.0/24.5/29.0 23.5/29.0/34.0 20.0/24.5/29.0 23.5/29.0/34.0
rate Heating Low/Medium/High m³/min 12.5/15.0/18.0 20.0/24.5/29.0 23.5/29.0/34.0 20.0/24.5/29.0 23.5/29.0/34.0
CHILLERS
External static Nom. Pa 30 40 50 40 50
pressure
Sound power level Cooling dBA 56.0 58.0 62.0 58.0 62.0
Sound pressure Cooling Low/Medium/High dBA 25.0/28.0/30.0 30.0/32.0/34.0 32.0/35.0/37.0 30.0/32.0/34.0 32.0/35.0/37.0
level Heating Low/Medium/High dBA 25.0/28.0/31.0 30.0/33.0/36.0 32.0/35.0/38.0 30.0/33.0/36.0 32.0/35.0/38.0
Control systems Infrared remote control BRC4C65 / BRC4C66
Wired remote control BRC1H52W/S/K / BRC1E53A / BRC1E53B / BRC1E53C / BRC1D52
FAN COIL
UNITS
Heating dBA - 71 73 - 71 73
Sound pressure Cooling Nom. dBA 46 53 54 53 54
UNITS
Piping OU - IU Max. m 50
length System Equivalent m 70
Chargeless m 30
Additional refrigerant charge kg/m See installation manual
Level difference IU - OU Max. m 30.0
Power supply Phase/Frequency/Voltage Hz/V 1~/50 /220-240 3~/50 /380-415
Current - 50Hz Maximum fuse amps (MFA) A 20 25 32 16
CONTROL
SYSTEMS
419
FBA-A(9) + ARXM-R / AZAS-MV / MY
420
INTRODUCTION
FBA-A(9) + RXM-R(9)/A Split
RESIDENTIAL
INDOOR AIR
QUALITY
with medium ESP
Slimmest yet most powerful medium
outblow
static pressure unit on the market
HEATING
› Combination with split outdoor units is ideal for small retail, rear
suction
offices and residential applications bottom
suction
› Slimmest unit in class, only 245mm (300mm built-in height) and FBA35-50A(9)
therefore narrow ceiling voids are no longer a challenge
› Low operation sound level down to 25dBA
SPLIT
› Medium external static pressure up to 150Pa facilitates using
flexible ducts of varying lengths
› Possibility to change ESP via wired remote control allows
optimisation of the supply air volume
SKY AIR
RXM-R BRC1H52W BRP069C81 with
multi zoning
Optimised supply air volume External static pressure (Pa) option
Automatically selects the most appropriate fan curve More details and final information can be found
to achieve the units’ nominal air flow within ±10% Air flow (rated)
Fan characteristic
curves by scanning or clicking the QR codes.
Why?
ROOFTOP
Air flow (actual)
After installation the real ducting will frequently
differ from the initially calculated air flow resistance
the real air flow may be much lower or higher
than nominal, leading to a lack of capacity or FBA-A(9) RXM-R
uncomfortable air temperature. Automatic Airflow Air flow (with
Duct resistance
automatic adjustment)
Adjustment function will adapt the unit’s fan speed curves
to any ducting automatically (10 or more fan curves
are available on every model), making installation
VRV
much faster ±10% Air flow (m3/min)
RXM-R9 RXM-A
Efficiency data FBA + RXM 35A9 + 35R9 50A9 + 50A 60A9 + 60R
Cooling capacity Nom. kW 3.40 5.00 5.70
Heating capacity Nom. kW 4.00 5.50 7.00
AIR PURIFICATION
VENTILATION &
COMMERCIAL
Space cooling Energy efficiency class A++ A+
Capacity Pdesign kW 3.40 5.00 5.70
SEER 6.23 6.27 5.91
Annual energy consumption kWh/a 191 279 336
Space heating Energy efficiency class A+
(Average climate) Capacity Pdesign kW 2.90 4.40 4.60
SCOP/A 4.07 4.06 4.01
Annual energy consumption kWh/a 996 1,517 1,607
INDUSTRY
MARINE
Indoor unit FBA 35A9 50A9 60A9
Dimensions Unit HeightxWidthxDepth mm 245x700x800 245x1,000x800
Weight Unit kg 28.0 35.0
Air filter Type Resin net
Fan Air flow Cooling Low/Medium/High m³/min 10.5/12.5/15.0 12.5/15.0/18.0
rate Heating Low/Medium/High m³/min 10.5/12.5/15.0 12.5/15.0/18.0
CHILLERS
External Nom. Pa 30
static
pressure
Sound power level Cooling dBA 60.0 56.0
Sound pressure Cooling Low/Medium/High dBA 29.0/32.0/35.0 25.0/28.0/30.0
level Heating Low/Medium/High dBA 29.0/34.0/37.0 25.0/28.0/31.0
Control systems Infrared remote control BRC4C65 / BRC4C66
Wired remote control BRC1H52W/S/K / BRC1E53A / BRC1E53B / BRC1E53C / BRC1D52
FAN COIL
UNITS
421
FDA-A + RZAG-NV1 / NY1 / RZASG-MV(1)/MY(1)
422
INTRODUCTION
FDA-A + RZA-D
RESIDENTIAL
INDOOR AIR
QUALITY
with high ESP
ESP up to 250 Pa, ideal for large sized spaces
HEATING
› High external static pressure up to 250Pa facilitates extensive duct low
outb
and grille network
rear
› Possibility to change ESP via wired remote control allows suction
optimisation of the supply air volume FDA200-250A
› Discretely concealed in the ceiling: only the suction and discharge
grilles are visible
SPLIT
› Optional drain pump
› Standard supplied suction filter simplifies installation
› Up to 26.4kW in heating mode
SKY AIR
RZA-D BRC1H52W BRP069C81
ROOFTOP
More details and final information
can be found by scanning or
VRV
clicking the QR codes. FDA-A RZA-D
Efficiency data FDA + RZA 200A + 200D 250A + 250D
Cooling capacity Min./Nom./Max. kW -/19.0/- -/22.0/-
AIR PURIFICATION
Heating capacity Min./Nom./Max. kW -/22.4/- -/24.0/-
VENTILATION &
COMMERCIAL
Space cooling Capacity Pdesign kW 19.0 22.0
SEER 6.26 5.38
ηs,c % 247 212
Annual energy consumption kWh/a 1,821 2,455
Space heating Capacity Pdesign kW 11.2 12.1
(Average climate) SCOP/A 3.59 3.55
ηs,h % 141 139
INDUSTRY
MARINE
Annual energy consumption kWh/a 4,368 4,765
Indoor unit FDA 200A 250A
Dimensions Unit HeightxWidthxDepth mm 470x1,490x1,100
Weight Unit kg 104 115
Air filter Type Resinnet
Fan Cooling Low/Medium/High m³/min
Air flow 36.0/50/64.0 43.0/56/69.0
CHILLERS
rate Heating Low/Medium/High m³/min 36.0/50.0/64.0 43.0/56.0/69.0
External Nom./High Pa 62/250
static
pressure
Sound power level Cooling dBA 69.0 71.0
Sound pressure Cooling Low / Medium / High dBA 36.0/39.0/43.0 37.0/40.0/44.0
level Heating Low / Medium / High dBA 36.0/39.0/43.0 37.0/40.0/44.0
FAN COIL
Control systems Wired remote control BRC1H52W/S/K / BRC1E53A / BRC1E53B / BRC1E53C / BRC1D52
UNITS
423
ADEA-A + ARXM-R / AZAS-MV
424
INTRODUCTION
FAA-B + RZAG-NV1 / NY1
RESIDENTIAL
INDOOR AIR
QUALITY
For rooms with no false ceilings nor free floor space
HEATING
› Flat, stylish front panel blends easily within any interior décor and
is easier to clean
› Can easily be installed in both new and refurbishment projects
› The air is comfortably spread up- and downwards thanks to FAA71B
5 different discharge angles that can be programmed via the
remote control
SPLIT
› Maintenance operations can be performed easily from the front of
the unit
› Flexible to install as the largest casing only weighs 17kg and piping
connection can be done at the bottom, left or right of the unit
SKY AIR
RZAG-NV1_NY1 BRC1H52W, BRP069C81
ROOFTOP
VRV
More details and final information
can be found by scanning or
clicking the QR codes. FAA-B RZAG-NV1 RZAG-NY1
AIR PURIFICATION
VENTILATION &
COMMERCIAL
Efficiency data FAA + RZAG 71B + 71NV1 100B + 100NV1 71B + 71NY1 100B + 100NY1
Cooling capacity Nom. kW 6.80 9.50 6.80 9.50
Heating capacity Nom. kW 7.50 10.80 7.50 10.80
Space cooling Energy efficiency class A++
Capacity Pdesign kW 6.80 9.50 6.80 9.50
SEER 6.58 6.42 6.58 6.42
Annual energy consumption kWh/a 362 518 362 518
INDUSTRY
Space heating Energy efficiency class A+
MARINE
(Average climate) Capacity Pdesign kW 4.70 7.80 4.70 7.80
SCOP/A 4.20 4.01 4.20 4.01
Annual energy consumption kWh/a 1,567 2,725 1,567 2,725
Indoor unit FAA 71B 100B 71B 100B
Dimensions Unit HeightxWidthxDepth mm 290x1,050x269 340x1,200x262 290x1,050x269 340x1,200x262
Weight Unit kg 14.0 18 14.0 18
CHILLERS
Fan Cooling Low/Medium/High m³/min
Air flow 12.1/13.4/16.2 18.7/21.1/23.0 12.1/13.4/16.2 18.7/21.1/23.0
rateHeating Low/Medium/High m³/min 12.7/14.2/16.9 18.7/20.9/23.0 12.7/14.2/16.9 18.7/20.9/23.0
Sound power level Cooling dBA 61.0 65.0 61.0 65.0
Heating dBA 61.0 65.0 61.0 65.0
Sound pressure Cooling Low/Medium/High dBA 40.0/42.0/45.0 41.0/45.0/49.0 40.0/42.0/45.0 41.0/45.0/49.0
level Heating Low/Medium/High dBA 40.0/42.0/45.0 41.0/45.0/49.0 40.0/42.0/45.0 41.0/45.0/49.0
FAN COIL
Piping OU - IU Max. m 55 85 55 85
length System Equivalent m 75 100 75 100
Chargeless m 40
Additional refrigerant charge kg/m See installation manual
Level difference IU - OU Max. m 30
Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240 3~/50/380-415
Current - 50Hz Maximum fuse amps (MFA) A 20 32 16
CONTROL
SYSTEMS
425
FAA-B + RZASG-MV(1)/MY(1)
426
INTRODUCTION
FAA-B + ARXM-R / AZAS-MV / MY
RESIDENTIAL
INDOOR AIR
QUALITY
For rooms with no false ceilings nor free floor space
HEATING
is easier to clean
› Can easily be installed in both new and refurbishment projects
› The air is comfortably spread up- and downwards thanks to
5 different discharge angles that can be programmed via the FAA71B
remote control
› Maintenance operations can be performed easily from the front of
SPLIT
the unit
› Flexible to install as the largest casing only weighs 17kg and piping
connection can be done at the bottom, left or right of the unit
SKY AIR
AZAS100-140MV1_MY1 BRC1H52W, BRP069C81
ROOFTOP
More details and final information
VRV
can be found by scanning or
clicking the QR codes. FAA-B ARXM-R AZAS-MV AZAS-MY
Efficiency data FAA + ARXM/AZAS 71B + ARXM71R 100B + AZAS100MV 100B + AZAS100MY
AIR PURIFICATION
Cooling capacity Nom./Max. kW 6.80/6.95 9.50 /-
VENTILATION &
COMMERCIAL
Heating capacity Nom./Max. kW 7.50/7.59 10.8 /-
Space cooling Energy efficiency class A+ A
Capacity Pdesign kW 6.80 9.50
SEER 5.77 5.25
Annual energy consumption kWh/a 412 633
Space heating Energy efficiency class A
(Average climate) Capacity Pdesign kW 4.50 6.00
INDUSTRY
MARINE
SCOP/A 3.81 3.81
Annual energy consumption kWh/a 1,652 2,205
Indoor unit FAA 71B 100B 100B
Dimensions Unit HeightxWidthxDepth mm 290x1,050x269 340x1,200x262
Weight Unit kg 14.0 18
Fan Cooling Low/Medium/High m³/min
Air flow 12.1/13.4/16.2 18.7/21.1/23.0
CHILLERS
rateHeating Low/Medium/High m³/min 12.7/14.2/16.9 18.7/20.9/23.0
Sound power level Cooling dBA 61.0 65.0
Heating dBA 61.0 65.0
Sound pressure Cooling Low/Medium/High dBA 40.0/42.0/45.0 41.0/45.0/49.0
level Heating Low/Medium/High dBA 40.0/42.0/45.0 41.0/45.0/49.0
Power supply Phase/Frequency/Voltage Hz/V 1~/50 /220-240 1~/50 /220-240
FAN COIL
Piping OU - IU Max. m 30
TRANSPORT
427
FTXM-R + RZAG-A
428
INTRODUCTION
FHA-A(9) + RZAG-A / NV1 / NY1
RESIDENTIAL
INDOOR AIR
QUALITY
For wide rooms with no false ceilings nor free floor space
HEATING
› Ideal for comfortable air flow in wide rooms thanks to Coanda
effect: up to 100° discharge angle
FHA60-71A9
SPLIT
› Even rooms with ceilings up to 3.8m can be heated up or cooled
down very easily without capacity loss
› Can easily be installed in both new and refurbishment projects
› Can easily be mounted in corners and narrow spaces, as it only
needs 30mm lateral service space
SKY AIR
RZAG35-60A BRC1H52W, BRP069A81
Air outlet
Air inlet
30 or more 30 or more
(Service space) (Service space) Obstruction
ROOFTOP
fan motor
› 5 different fan speeds available for maximum comfort final information
can be found by
scanning or clicking
the QR codes. RZAG-NV1 RZAG-NY1
Efficiency data FHA + RZAG 35A9+35A 50A9+50A 60A9+60A 71A9+71NV1 100A+100NV1 125A+125NV1 140A+140NV1 71A9+71NY1 100A+100NY1 125A+125NY1 140A+140NY1
Cooling capacity Min./Nom./Max. kW 1.70/3.50/4.50 1.70/5.00/6.00 1.90/6.00/6.80 -/6.80/- -/9.50/- -/12.1/- -/13.4/- -/6.80/- -/9.50/- -/12.1/- -/13.4/-
VRV
Heating capacity Min./Nom./Max. kW 1.40/4.00/5.50 1.70/5.80/6.50 1.70/7.00/7.50 -/7.50/- -/10.8/- -/13.5/- -/15.5/- -/7.50/- -/10.8/- -/13.5/- -/15.5/-
Space cooling Energy efficiency class A++ - A++ -
Capacity Pdesign kW 3.50 5.00 6.00 6.80 9.50 12.1 13.4 6.80 9.50 12.1 13.4
SEER 6.40 6.80 6.60 7.11 6.42 7.14 6.42 7.11 6.42 7.14 6.42
AIR PURIFICATION
ηs,c % - 283 254 - 283 254
VENTILATION &
COMMERCIAL
Annual energy consumption kWh/a 191 257 318 335 518 1,017 1,253 335 518 1,017 1,253
Space heating Energy efficiency class A+ A++ - A+ A++ -
(Average climate) Capacity Pdesign kW 3.10 4.00 4.60 4.70 7.80 9.52 4.70 7.80 9.52
SCOP/A 4.10 4.30 4.20 4.32 4.61 4.20 4.30 4.32 4.61 4.20 4.30
ηs,h % - 165 169 - 165 169
Annual energy consumption kWh/a 1,058 1,302 1,633 1,523 2,369 3,174 3,100 1,523 2,369 3,174 3,100
Indoor unit FHA 35A9 50A9 60A9 71A9 100A 125A 140A 71A9 100A 125A 140A
INDUSTRY
MARINE
Dimensions Unit HeightxWidthxDepth mm 235x960x690 235x1,270x690 235x1,590x690 235x1,270x690 235x1,590x690
Weight Unit kg 26 27 32 34 41 34 41
Air filter Type Resinnet
Fan Air flow Cooling Low/Medium/High m³/min 10.0/11.5/14.0 10.0/12.0/15.0 11.5/15.0/19.5 14.0/17.0/20.5 20.0/24.0/28.0 23.0/27.0/31.0 24.0/29.0/34.0 14.0/17.0/20.5 20.0/24.0/28.0 23.0/27.0/31.0 24.0/29.0/34.0
rate Heating Low/Medium/High m³/min 10.0/11.5/14.0 10.0/12.0/15.0 11.5/15.0/19.5 14.0/17.0/20.5 20.0/24.0/28.0 23.0/27.0/31.0 24.0/29.0/34.0 14.0/17.0/20.5 20.0/24.0/28.0 23.0/27.0/31.0 24.0/29.0/34.0
Sound power level Cooling dBA 53.0 54.0 55.0 60.0 62.0 64.0 55.0 60.0 62.0 64.0
Heating dBA 53.0 54.0 55.0 60.0 62.0 64.0 55.0 60.0 62.0 64.0
CHILLERS
Sound pressure Cooling Low/High dBA 31.0/36.0 32.0/37.0 33.0/37.0 34.0/38.0 34.0/42.0 37.0/44.0 38.0/46.0 34.0/38.0 34.0/42.0 37.0/44.0 38.0/46.0
level Heating Nom./High dBA 34.0/36.0 35.0/37.0 36.0/38.0 38.0/42.0 41.0/44.0 42.0/46.0 36.0/38.0 38.0/42.0 41.0/44.0 42.0/46.0
Control systems Infrared remote control BRC7GA53-9 / BRC7GA56
Wired remote control BRC1D528 / BRC1H51(9)W/S/K7 / BRC1H52W/S/K / BRC1H81W7 / BRC1H81S7 / BRC1E53A/B/C7 / BRC1H82W/S/K
Power supply Phase/Frequency/Voltage Hz/V 1~/50/60/220-240/220
Piping connections Drain VP20
FAN COIL
UNITS
Outdoor unit RZAG 35A 50A 60A 71NV1 100NV1 125NV1 140NV1 71NY1 100NY1 125NY1 140NY1
Dimensions Unit HeightxWidthxDepth mm 734x870x373 870x1,100x460
Weight Unit kg 52 81 85 95 81 85 94
Sound power level Cooling dBA 62.0 63.0 64.0 64 66 69 70 64 66 69 70
Heating dBA 62.0 63.0 64.0 - 68 71 - 68 71
Sound pressure Cooling Nom. dBA 48.0 49.0 50.0 46 47 49 50 46 47 49 50
AIR HANDLING
Piping OU - IU Max. m 50 55 85 55 85
TRANSPORT
429
FHA-A(9) + RZASG-MV(1)/MY(1)
430
INTRODUCTION
NEW FHA-A(9) + AZAS-MV/MY
RESIDENTIAL
INDOOR AIR
QUALITY
For wide rooms with no false ceilings nor free floor space
HEATING
effect: up to 100° discharge angle
› Even rooms with ceilings up to 3.8m can be heated up or cooled
down very easily without capacity loss
› Can easily be installed in both new and refurbishment projects FHA60-71A9
› Can easily be mounted in corners and narrow spaces, as it only
needs 30mm lateral service space
SPLIT
› 5 different fan speeds available for maximum comfort
› Stylish unit blends easily with any interior. The flaps close entirely
when the unit is not operating and there are no air intake grilles
visible
SKY AIR
AZAS-MV/MY BRC1H52W, BRP069A81
ROOFTOP
More details and final information
can be found by scanning or
clicking the QR codes. FHA-A(9) AZAS-MV AZAS-MY
Efficiency data FHA + AZAS 100A + 100MV 125A + 125MV 140A + 140MV 100A + 100MY 125A + 125MY 140A + 140MY
Cooling capacity Nom. kW 9.50 12.1 13.4 9.50 12.1 13.4
VRV
Heating capacity Nom. kW 10.8 13.5 15.5 10.8 13.5 15.5
Space cooling Energy efficiency class A - A -
Capacity Pdesign kW 9.50 12.1 13.4 9.50 12.1 13.4
SEER 5.6
ηs,c % - 221 - 221
AIR PURIFICATION
VENTILATION &
COMMERCIAL
Annual energy consumption kWh/a 594 1,297 1,436 594 1,297 1,436
Space heating Energy efficiency class A - A -
(Average climate) Capacity Pdesign kW 6.00 7.80 6.00 7.80
SCOP/A 3.87 3.75 3.81 3.87 3.75 3.81
ηs,h % - 147 149 - 147 149
Annual energy consumption kWh/a 2,171 2,240 2,866 2,171 2,240 2,866
Indoor unit FHA 100A 125A 140A 100A 125A 140A
INDUSTRY
MARINE
Dimensions Unit HeightxWidthxDepth mm 235x1,590x690
Weight Unit kg 41
Air filter Type Resin net
Fan Air flow Low/Medium/High m³/min
Cooling 20.0/24.0/28.0 23.0/27.0/31.0 24.0/29.0/34.0 20.0/24.0/28.0 23.0/27.0/31.0 24.0/29.0/34.0
rate Low/Medium/High m³/min
Heating 20.0/24.0/28.0 23.0/27.0/31.0 24.0/29.0/34.0 20.0/24.0/28.0 23.0/27.0/31.0 24.0/29.0/34.0
Sound power level Cooling dBA 60.0 62.0 64.0 60.0 62.0 64.0
Heating dBA 60.0 62.0 64.0 60.0 62.0 64.0
CHILLERS
Sound pressure Cooling Low/High dBA 34.0/42.0 37.0/44.0 38.0/46.0 34.0/42.0 37.0/44.0 38.0/46.0
level Heating Nom./High dBA 38.0/42.0 41.0/44.0 42.0/46.0 38.0/42.0 41.0/44.0 42.0/46.0
Control systems Infrared remote control BRC7GA53-9 / BRC7GA56
Wired remote control RC1H52W/S/K; BRC1E53A; BRC1E53B; BRC1E53C; BRC1D52
Power supply Phase/Frequency/Voltage Hz/V 1~/50/60/220-240/220
Piping connections Drain VP20
FAN COIL
UNITS
Piping OU - IU Max. m 30
length System Equivalent m 50
Chargeless m 30
Additional refrigerant charge kg/m See installation manual
Level difference IU - OU Max. m 30.0
Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240 3~/50/380-415
Current - 50Hz Maximum fuse amps (MFA) A 25 32 16
CONTROL
SYSTEMS
431
FHA-A(9) + RXM-R(9)/A Split
432
INTRODUCTION
FUA-A + RZAG-NV1 / NY1
RESIDENTIAL
INDOOR AIR
QUALITY
suspended unit
Unique Daikin unit for high rooms with no
false ceilings nor free floor space
HEATING
› Combining with Sky Air Advance-series ensures good value for
money for all types of commercial applications
› Even rooms with ceilings up to 3.5m can be heated up or cooled FUA-A
down very easily without capacity loss
› Can easily be installed in both new and refurbishment projects
SPLIT
› Unified indoor unit range for R-32 and R-410A
› Individual flap control: flexibility to suit every room layout without
changing the location of the unit!
SKY AIR
RZAG-NV1_NY1 BRC1H52W, BRP069A81
› 5 different discharge angles between 0 and 60° can be › Stylish modern casing finished in pure white (RAL9010) and iron
programmed via the remote control grey (RAL7011) blends easily with any interior
› Optimum comfort guaranteed with automatic air flow
ROOFTOP
0° to 60°
adjustment to the required load
› Standard drain pump with 720mm lift increases flexibility and
installation speed
More details and final information can be
found by scanning or clicking the QR codes.
VRV
FUA-A RZAG-NV1 RZAG-NY1
Efficiency data FUA + RZAG 71A + 71NV1 100A + 100NV1 125A + 125NV1 71A + 71NY1 100A + 100NY1 125A + 125NY1
AIR PURIFICATION
VENTILATION &
Cooling capacity Nom. kW 6.80 9.50 12.1 6.80 9.50 12.1
COMMERCIAL
Heating capacity Nom. kW 7.50 10.8 13.5 7.50 10.8 13.5
Space cooling Energy efficiency class A++ - A++ -
Capacity Pdesign kW 6.80 9.50 12.1 6.80 9.50 12.1
SEER 7.02 6.42 6.39 7.02 6.42 6.39
ηs,c % - 253 - 253
Annual energy consumption kWh/a 339 518 1,136 339 518 1,136
Space heating Energy efficiency class A+ - A+ -
INDUSTRY
(Average climate) Capacity Pdesign kW 4.70 7.80 9.52 4.70 7.80 9.52
MARINE
SCOP/A 4.20 4.50 4.26 4.20 4.50 4.26
ηs,h % - 167 - 167
Annual energy consumption kWh/a 1,567 2,427 3,129 1,567 2,427 3,129
Indoor unit FUA 71A 100A 125A 71A 100A 125A
Dimensions Unit HeightxWidthxDepth mm 198x950x950
Weight Unit kg 25.0 26.0 25.0 26.0
CHILLERS
Air filter Type Resinnet
Fan Air flow Cooling Low/Medium/High m³/min 16.0/19.5/23.0 20.0/25.5/31.0 20.5/26.5/32.5 16.0/19.5/23.0 20.0/25.5/31.0 20.5/26.5/32.5
rate Heating Low/Medium/High m³/min 16.0/19.5/23.0 20.0/25.5/31.0 20.5/26.5/32.5 16.0/19.5/23.0 20.0/25.5/31.0 20.5/26.5/32.5
Sound power level Cooling dBA 59 64 65 59 64 65
Sound pressure Cooling Low/High dBA 35/41 39/46 40/47 35/41 39/46 40/47
level Heating Low/High dBA 35/41 39/46 40/47 35/41 39/46 40/47
Control systems Wired remote control BRC1H52W/S/K / BRC1E53A/B/C / BRC1D52
FAN COIL
UNITS
Heating dBA - 68 - 68
Sound pressure Cooling Nom. dBA 46 47 49 46 47 49
UNITS
Piping OU - IU Max. m 55 85 55 85
length System Equivalent m 75 100 75 100
Chargeless m 40
Level difference IU - OU Max. m 30
Additional refrigerant charge kg/m See installation manual
Power supply Phase/Frequency/Voltage Hz/V 1~/50 /220-240 3~/50 /380-415
Current - 50Hz Maximum fuse amps (MFA) A 20 32 16
CONTROL
SYSTEMS
433
FUA-A + RZASG-MV(1)/MY(1)
434
INTRODUCTION
FVA-A + RZAG-NV1 / NY1
RESIDENTIAL
INDOOR AIR
QUALITY
For commercial spaces with high ceilings
HEATING
› Decrease of temperature variation by automatic fan speed
selection or freely selectable 3-step fan speed.
› Improved comfort as a result of better airflow distribution from
the vertical out blow which allows manual adjustment of air outlet RZAG-NV1_NY1
blades at the top of the unit.
› Selectable horizontal out blow to better suit the layout of the
SPLIT
room (via wired remote controller BRC1E*/BRC1H*)
All up Up
SKY AIR
BRC1H52W, BRP069A81 FVA-A
All down Down
ROOFTOP
More details and final information
can be found by scanning or
clicking the QR codes. FVA-A RZAG-NV1 RZAG-NY1
Efficiency data FVA + RZAG 71A + 71NV1 100A + 100NV1 125A + 125NV1 140A + 140NV1 71A + 71NY1 100A + 100NY1 125A + 125NY1 140A + 140NY1
Cooling capacity Nom. kW 6.80 9.50 12.1 13.4 6.80 9.50 12.1 13.4
Heating capacity Nom. kW 7.50 10.8 13.5 15.5 7.50 10.8 13.5 15.5
VRV
Space cooling Energy efficiency class A++ - A++ -
Capacity Pdesign kW 6.80 9.50 12.1 13.4 6.80 9.50 12.1 13.4
SEER 6.34 6.40 6.41 6.12 6.34 6.40 6.41 6.12
ηs,c % - 253 242 - 253 242
AIR PURIFICATION
Annual energy consumption kWh/a 376 520 1,133 1,314 376 520 1,133 1,314
VENTILATION &
COMMERCIAL
Space heating Energy efficiency class A+ - A+ -
(Average climate) Capacity Pdesign kW 4.70 7.80 9.52 4.70 7.80 9.52
SCOP/A 4.05 4.20 4.15 3.94 4.05 4.20 4.15 3.94
ηs,h % - 163 155 - 163 155
Annual energy consumption kWh/a 1,625 2,600 3,209 3,383 1,625 2,600 3,209 3,383
Indoor unit FVA 71A 100A 125A 140A 71A 100A 125A 140A
INDUSTRY
Dimensions Unit HeightxWidthxDepth mm 1,850x600x270 1,850x600x350 1,850x600x270 1,850x600x350
MARINE
Weight Unit kg 42 50 42 50
Air filter Type Resin net
Fan Air flow Cooling Low/Medium/ m³/min 14/16/18 22/25/28 24/26/28 26/28/30 14/16/18 22/25/28 24/26/28 26/28/30
rate High
Heating Low/Medium/ m³/min 14/16/18 22/25/28 24/26/28 26/28/30 14/16/18 22/25/28 24/26/28 26/28/30
High
CHILLERS
Sound power level Cooling dBA 55 62 63 65 55 62 63 65
Sound pressure Cooling Low/High dBA 38/43 44/50 46/51 48/53 38/43 44/50 46/51 48/53
level Heating Nom./High dBA 41/43 47/50 48/51 51/53 41/43 47/50 48/51 51/53
Control systems Wired remote control BRC1H52W/S/K / BRC1E53A / BRC1E53B / BRC1E53C / BRC1D52
Power supply Phase/Frequency/Voltage Hz/V 1~/50/60/220-240/220
Piping connections Drain I.D. 20/O.D. 26
FAN COIL
Outdoor unit RZAG 71NV1 100NV1 125NV1 140NV1 71NY1 100NY1 125NY1 140NY1
UNITS
Piping OU - IU Max. m 55 85 55 85
length System Equivalent m 75 100 75 100
Chargeless m 40
Level difference IU - OU Max. m 30
Additional refrigerant charge kg/m See installation manual
Power supply Phase/Frequency/Voltage Hz/V 1~/50 /220-240 3~/50 /380-415
Current - 50Hz Maximum fuse amps (MFA) A 20 32 16
CONTROL
SYSTEMS
435
FVA-A + RZASG-MV(1)/MY(1)
All up Up
436
INTRODUCTION
NEW FVA-A + AZAS-MV/MY
RESIDENTIAL
INDOOR AIR
QUALITY
For commercial spaces with high ceilings
HEATING
selection or freely selectable 3-step fan speed.
› Improved comfort as a result of better airflow distribution from
the vertical out blow which allows manual adjustment of air outlet
blades at the top of the unit. AZAS-MV/MY
› Selectable horizontal out blow to better suit the layout of the
room (via wired remote controller BRC1E*/BRC1H*)
SPLIT
Side view blades air outlet
All up Up
SKY AIR
BRC1H52W, BRP069A81 FVA-A
All down Down
ROOFTOP
More details and final information
can be found by scanning or
clicking the QR codes. FVA-A AZAS-MV AZAS-MY
VRV
Efficiency data FVA + AZAS 100A + 100MV 125A + 125MV 140A + 140MV 100A + 100NY 125A + 125NY 140A + 140NY
Cooling capacity Nom. kW 9.50 12.1 13.4 9.50 12.1 13.4
Heating capacity Nom. kW 10.8 13.5 15.5 10.8 13.5 15.5
Space cooling Energy efficiency class A - A -
Capacity Pdesign kW 9.50 12.1 13.4 9.50 12.1 13.4
AIR PURIFICATION
VENTILATION &
COMMERCIAL
SEER 5.5 5.3 5.4 5.5 5.3 5.4
ηs,c % - 209 213 - 209 213
Annual energy consumption kWh/a 605 1,370 1,489 605 1,370 1,489
Space heating Energy efficiency class A - A -
(Average climate) Capacity Pdesign kW 6.00 7.80 6.00 7.80
SCOP/A 3.79 3.56 3.81 3.79 3.56 3.81
ηs,h % - 139 149 - 139 149
INDUSTRY
Annual energy consumption kWh/a 2,217 2,360 2,866 2,217 2,360 2,866
MARINE
Indoor unit FVA 100A 125A 140A 100A 125A 140A
Dimensions Unit HeightxWidthxDepth mm 1,850x600x350 1,850x600x350
Weight Unit kg 50 50
Air filter Type Resin net
Fan Air flow Low/Medium/High m³/min
Cooling 22/25/28 24/26/28 26/28/30 22/25/28 24/26/28 26/28/30
rate Low/Medium/High m³/min
Heating 22/25/28 24/26/28 26/28/30 22/25/28 24/26/28 26/28/30
CHILLERS
Sound power level Cooling dBA 62 63 65 62 63 65
Sound pressure Cooling Low/High dBA 44/50 46/51 48/53 44/50 46/51 48/53
level Heating Nom./High dBA 47/50 48/51 51/53 47/50 48/51 51/53
Control systems Wired remote control BRC1H52W/S/K / BRC1E53A / BRC1E53B / BRC1E53C / BRC1D52
Power supply Phase/Frequency/Voltage Hz/V 1~/50/60/220-240/220
Piping connections Drain I.D. 20/O.D. 26
FAN COIL
UNITS
Piping OU - IU Max. m 30
length System Equivalent m 50
Chargeless m 30
Additional refrigerant charge kg/m See installation manual
Level difference IU - OU Max. m 30.0
Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240 3~/50/380-415
Current - 50Hz Maximum fuse amps (MFA) A 25 32 16
CONTROL
SYSTEMS
437
FNA-A9 + RZAG-A
438
INTRODUCTION
FNA-A9 + RXM-R(9)/A Split
RESIDENTIAL
INDOOR AIR
QUALITY
Designed to be concealed in walls
HEATING
› Discretely concealed in the wall: only the suction and discharge
grilles are visible
› Requires very little installation space as the depth is only 200mm
› Its low height (620 mm) enables the unit to fit perfectly beneath a FNA-A9
window
› High ESP allows flexible installation
SPLIT
SKY AIR
RXM-R BRC1H52W BRP069C81
ROOFTOP
Efficiency data FNA + RXM 25A9 + 25R9 35A9 + 35R9 50A9 + 50A 60A9 + 60R
Cooling capacity Nom. kW 2.60 3.40 5.00 6.00
Heating capacity Nom. kW 3.20 4.00 5.80 7.00
Power input Cooling Nom. kW 0.68 1.10 1.48 2.22
Heating Nom. kW 0.80 1.15 1.74 2.25
Space cooling Energy efficiency class A+ A
VRV
Capacity Pdesign kW 2.60 3.40 5.00 6.00
SEER 5.68 5.70 5.77 5.56
Annual energy consumption kWh/a 160 209 303 378
Space heating Energy efficiency class A+
(Average climate) Capacity
AIR PURIFICATION
Pdesign kW 2.80 2.90 4.00 4.60
VENTILATION &
COMMERCIAL
SCOP/A 4.24 4.05 4.09 4.16
Annual energy consumption kWh/a 924 1,002 1,368 1,547
Nominal efficiency EER 3.80 3.09 3.38 2.70
COP 4.00 3.48 3.34 3.11
Annual energy consumption kWh 342 550 740 1,111
Energy labeling Directive Cooling/Heating A/A B/B A/C D/D
Indoor unit FNA 25A9 35A9 50A9 60A9
INDUSTRY
MARINE
Dimensions Unit HeightxWidthxDepth mm 620/720x790x200 620/720x1,190x200
Weight Unit kg 23.0 30.0
Air filter Type Resinnet
Fan Air flow Cooling Low/High m³/min 7.3/8.7 13.5/16.0
rate Heating Low/High m³/min 7.3/8.7 13.5/16.0
External static Nom./High Pa 30/48 40/49
pressure
CHILLERS
Sound power level Cooling dBA 53.0 56.0
Sound pressure Cooling Low/Medium/High dBA 28.0/31.0/33.0 30.0/33.0/36.0
level Heating Low/Nom./High dBA 28.0/31.0/33.0 30.0/33.0/36.0
Control systems Infrared remote control BRC4C65
Wired remote control BRC1H52W/S/K / BRC1E53A / BRC1E53B / BRC1E53C / BRC1D52
Power supply Phase/Frequency/Voltage Hz/V 1~/50/60/220-240/220
FAN COIL
UNITS
NEW
Outdoor unit RXM 25R9 35R9 50A 60R
Dimensions Unit HeightxWidthxDepth mm 552x840x350 734x954x401
Weight Unit kg 32 49.0
Sound pressure Cooling Nom. dBA 46.0 49.0 48.0
AIR HANDLING
439
Benefits of Biddle air curtains
› Connectable to ERQ and VRV units
› Unified range for R-32 and R-410A refrigerant
› payback period of less then 1.5 years compared to installing an
electric air curtain
electric air
curtain
10,000
8,000
total cost
Daikin heat pump
6,000
with Biddle air curtain
4,000
2,000
0
1 2 years
S M L S M L S M L
440
INTRODUCTION
NEW CYA-S/M/L-DK-F/C/R
New R-32
range
Biddle air curtain
RESIDENTIAL
INDOOR AIR
QUALITY
› Connectable to ERQ and VRV DX outdoor units
› Unified model for R-32 and R-410A refrigerant
› Free-hanging model (F): easy wall mounted installation
› Cassette model (C): mounted into a false ceiling leaving only the
HEATING
decoration panel visible
› Recessed model (R): neatly concealed in the ceiling
› A payback period of less then 1.5 years compared to installing an electric
air curtain CYA150DK80FSC
› Provides virtually free air curtain heating via recovered heat from indoor
units in cooling mode (in case of VRV heat recovery)
› Easy and quick to install at reduced costs since no additional water
SPLIT
systems, boilers and gas connections are required
SKY AIR
CYA150DK80CSC CYA150DK80RSC
ROOFTOP
More details and final information
can be found by scanning or
clicking the QR codes. CYA
BIDDLE COMFORT AIR CURTAIN (CA)
Small Medium
CYAS100DK80* CYAS150DK80* CYAS200DK100* CYAS250DK140* CYAM100DK80* CYAM150DK80* CYAM200DK100* CYAM250DK140*
Heating capacity Speed 3 kW 6,94 8,6 10,9 15,2 8,65 10,5 12,5 18,6
VRV
Power input Fan only Nom. kW 0,14 0,21 0,28 0,36 0,27 0,40 0,53 0,67
Heating Nom. kW 0,14 0,21 0,28 0,36 0,27 0,40 0,53 0,67
Delta T Speed 3 K 17,7 14,6 13,9 15,5 16 12,9 12,7 13,8
Casing Colour B: RAL9016 / S: RAL9006 B: RAL9016 / S: RAL9006
AIR PURIFICATION
VENTILATION &
Dimensions Unit Height F/C/R mm 270/270/270 270/270/270
COMMERCIAL
Width F/C/R mm 1000/1000/1048 1500/1500/1548 2000/2000/2048 2500/2500/2548 1000/1000/1048 1500/1500/1548 2000/2000/2048 2500/2500/2548
Depth F/C/R mm 590/821/561 590/821/561
Required ceiling void > mm mm 420 420
Door height Max. m 2,3 2,5
Door width Max. m 1 1,5 2 2,5 1 1,5 2 2,5
Weight Unit kg 56/59/61 66/83/88 83/102/108 107/129/137 57/68/66 73/88/93 94/111/117 108/136/144
Fan Speed 3 m³/h 1164 1746 2328 2910 1605 2408 2910 4013
INDUSTRY
Sound pressure level Heating Speed 3 dBA 47 49 50 51 50 51 53 54
MARINE
Refrigerant GWP 675/2087,5 675/2087,5
Type R32/R410A R32/R410A
Piping connections Liquid OD mm 6,35 9,52 6,35 9,52
Gas OD mm 12,7 15,9 12,7 15,9
Air filter Type Vacuum cleanable filter G1
Power supply Frequency Hz 50Hz 50Hz
Voltage V 230V 230V
CHILLERS
Maximum fuse amps (MFA) A 16 16
Large
CYAL100DK125* CYAL150DK200* CYAL200DK250* CYAL250DK250*
Heating capacity Speed 3 kW
14,4 21,5 27,6 29,7
Power input Fan only Nom. kW 0,48 0,72 0,96 1,20
FAN COIL
Type R32/R410A
TRANSPORT
441
SKY AIR ALPHA-SERIES - LOW HEIGHT UNIT
442
INTRODUCTION
RESIDENTIAL
INDOOR AIR
QUALITY
HEATING
A range of industry
leading technology
SPLIT
outdoor units
Products overview outdoor units 444
Benefits overview outdoor units 445
SKY AIR
446
Low sound enclosure 447
Variable Refrigerant Temperature 448
ROOFTOP
units RZAG-A
range
450
450
RZAG-NV1/NY1 450
RZASG-MV(1)/MY(1) 451
VRV
RZA-D 452
ARXM-R/
AZAS-MV/MY 453
AIR PURIFICATION
VENTILATION &
COMMERCIAL
Multi model and VRV range
See Split or VRV chapter
Options & Accessories 454
INDUSTRY
MARINE
CHILLERS
FAN COIL
UNITS
443
Outdoor units
Low height.
High value.
RZASG-
MV(1)/
Air Heat MY(1)
cooled pump - Technology and comfort combined for commercial applications
- Very compact and easy to install outdoor units (A+++ - D)
- Maximum piping length up to 50m (RZA-D up to 100m)
- Replacement technology
- Operation range down to -15°C both cooling and in heating (RZA-D down to -20°C) RZA-D
- Pair, twin, triple and double twin application
444
INTRODUCTION
Outdoor units
RESIDENTIAL
INDOOR AIR
QUALITY
RZASG-
RZAG-A RZAG-NV1/NY1 RZA-D AZAS-MV/MY ARXM-R(9)
MV(1)/MY(1)
HEATING
Seasonal efficiency gives a more realistic
Seasonal efficiency - indication on how efficient air conditioners
Smart use of energy operate over an entire heating or cooling (A+++ - D) (A+++ - D) (A+++ - D)
-
(A+++ - D) (A+++ - D)
season.
We care icons
SPLIT
decreased energy consumption (up to 30%)
and more stable temperatures.
Quick and quality system replacement in the
Replacement
technology most cost effective way
Lowers the operation sound of the outdoor unit
Night quiet
Comfort
SKY AIR
automatically.
Auto cooling-heating Automatically selects cooling or heating mode
changeover to achieve the set temperature.
The intelligent systems ensures highest energy
Variable refrigeration
temperature
savings with additional comfort to better suit
application requirements.
ROOFTOP
2, 3 or 4 indoor units can be connected to only
1 outdoor unit. All indoor units operate within
Twin/triple/double
twin application the same mode (cooling or heating) from one
Other functions
remote control.
Outdoor units are fitted with a swing
Swing compressor compressor, renowned for its low noise and
high reliability
VRV
Guaranteed Daikin is suitable for all climates, even
operation
down to -20°C
withstanding severe winter conditions with an
operation range down to -20°C.
For high sensible, infrastructure cooling
applications, dedicated infrastructure
AIR PURIFICATION
VENTILATION &
Infrastructure cooling
COMMERCIAL
cooling settings and allowing asymmetric
combinations enhance the system’s reliability.
Dedicated Daikin developed and tested low
Low sound enclosure sound enclosure, reducing sound power by up
to -10 dB(A)
• •
INDUSTRY
MARINE
Technical benefit overview
CHILLERS
RZASG-
RZAG-A RZAG-NV1/NY1 RZA-D AZAS-MV/MY ARXM-R(9)
MV(1)/MY(1)
Compact single fan casing on the entire range
Maximum piping length 50 m 85 m 50 m 100 m 30 m 30 m
7 segment display
UNITS
445
Low height.
High value.
Unique, low-height
single fan range
easy to transport
870 mm
Market-leading
serviceability
and handling
446
INTRODUCTION
Low sound enclosure
RESIDENTIAL
INDOOR AIR
QUALITY
EKLN140A
HEATING
SPLIT
– 10 dB(A)!
SKY AIR
Benefits
Dedicated Daikin option for: Easy to integrate
› Sky Air Alpha-series › Anthracite (RAL 7016), highly aesthetic finishing
ROOFTOP
› Sky Air Advance-series › Mechanically designed to perfectly suit the Sky Air Alpha/
› VRV 5 S-series Advance and VRV 5 S-series casings
› Self-supporting; can be installed on any flat surface
Fully optimised and tested in Daikin factory
› Guaranteed performance levels Fast & easy installation & servicing
(sound, capacity, efficiency) › 100 % weather resistant
› Easy opening to access most system components
VRV
Outdoor unit sound reduction of up to
-10 dB(A) on sound power levels Durable
› Enabling to meet local sound requirements › 3 years warranty on all components
AIR PURIFICATION
› Increased flexibility to apply outdoor units › Made of stainless steel with robust double layer powder
VENTILATION &
COMMERCIAL
› Reduces sound on the entire sound spectrum coating, ensuring maximum corrosion resistance
INDUSTRY
MARINE
Tried and tested:
values that you can rely on
CHILLERS
Our low sound enclosure eliminates possible
problems and reduces your workload significantly:
Depth mm 1,500
TRANSPORT
447
Outdoor units
Variable Refrigerant
Temperature
› The system automatically increases its evaporating Min. Te1 Depending on the gap between
indoor t° and set point the Te
temperature (Te) when the gap between the actual will be increased or decreased
indoor temperature (Tin) and the setpoint (Tset) is Lin
ear
Te
becoming smaller, increasing comfort and provi- li mit
ding more stable operation Min. Te2
20° 31° Ta
Outdoor t° trigger values
Quick cooling
(selected on remote control)
of operation
Td
Improved comfort:
higher discharge temperatures
With VRT
› More stable and continuous operation No VRT
› Average discharge temperature increased with 3~4°C
448
INTRODUCTION
Outdoor units
RESIDENTIAL
INDOOR AIR
QUALITY
Replacement technology
HEATING
The quick and quality way of upgrading R-22 and R-410A systems
SPLIT
Benefits to increase The benefits will convince your customer
your profit
SKY AIR
To prevent unexpected breakdown
Optimise your business
To lower running costs
Less installation time
To protect the environment
ROOFTOP
Tackle more projects in less time thanks to faster
installation. It is more profitable than replacing the
full system with new piping. To improve comfort
VRV
your competitive edge.
- c opper pipes used in air conditioning systems tested by Daikin
Replace non-Daikin systems will last over 60 years after installation.
AIR PURIFICATION
VENTILATION &
COMMERCIAL
It is a trouble-free replacement solution for
Daikin systems and for systems made by other
manufacturers.
Easy as one-two-three
INDUSTRY
MARINE
A simple solution for replacement technology
enables you to handle more projects for more
customers in less time and offer them the best price!
Everybody gains.
CHILLERS
How does it work? Unique technologies
› Cleaning free piping re-usage thanks to unique hepta filtering for maximum
The Daikin low-cost upgrade solution particle reduction
HPS-A
LPS
✓
REFRIGERATION
COMMERCIAL &
449
RZAG-A / NV1 / NY1
FDXM-F9
FHA-A(9)
FBA-A(9)
FTXM-R
FNA-A9
FCAG-B
FFA-A9
FDA-A
FUA-A
FVA-A
FAA-B
capacity class 71 100 125 140 35 50 60 71 100 125 140 35 50 60 125 35 50 60 35 50 60 71 100 125 140 35 50 60 71 100 125 140 71 100 35 50 60 71 71 100 125 35 50 60 71 100 125 140
RZAG35A P P P P P P P
RZAG50A P P P P P P P
RZAG60A P P P P P P P
RZAG71NV1 RZAG71NY1 P 2 P 2 2 2 P 2 P P P 2 P
RZAG100NV1 RZAG100NY1 P 3 2 P 3 2 3 2 3 2 P 3 2 P P P 3 2 P
RZAG125NV1 RZAG125NY1 P 4 3 2 P 4 3 2 P 4 3 2 4 3 2 P 4 3 2 P P 4 3 2 P
RZAG140NV1 RZAG140NY1 2 P 4 3 2 P 4 3 4 3 4 3 2 P 4 3 2 P 2 2 4 3 2 P
P = pair application; 2/3/4 = twin/triple/double twin application
FBA-A(9)
FTXM-R
FNA-A9
FCAG-B
FFA-A9
FUA-A
FVA-A
FAA-B
capacity class 35 50 60 71 71 100 35 50 60 71 100 125 140 35 50 60 71 100 125 140 35 50 60 71 100 125 35 50 60 71 100 125 140 35 50 60 71 100 125 140 35 50 60 71 100 125 140
RZAG35A P P P P P P P
RZAG50A P P P P P P P
RZAG60A P P P P
RZAG71NV1 RZAG71NY1 P 3 2 P 3 2 P 3 2 P 3 2 P 3 2 P 3 2 P
RZAG100NV1 RZAG100NY1 2 4 3 2 P 4 3 2 P 4 3 2 4 3 P 4 3 2 P 4 3 2 P
RZAG125NV1 RZAG125NY1 2 4 3 2 P 4 3 2 P 4 3 2 4 3 P 4 3 2 P 4 3 2 P
RZAG140NV1 RZAG140NY1 2 4 3 2 P 4 3 2 P 4 3 2 4 3 P 4 3 2 P 4 3 2 P
P = Pair, 2 = Twin, 3 = Triple, 4 = Double twin; For more information on infrastructure cooling options refer to infrastructure cooling catalogue.
450
INTRODUCTION
RZASG-MV(1)/MY(1)
RESIDENTIAL
INDOOR AIR
QUALITY
Technology and comfort combined
for commercial applications
› High efficiency:
HEATING
- Energy labels up to A++ (cooling) / A+ (heating)
- Compressor offers substantial efficiency improvements
› Very compact and easy to install
› Replace existing systems with R-32 technology without needing to
replace the piping
› Guarantees operation in both heating and cooling mode down to
SPLIT
-15°C
› Refrigerant cooled PCB guarantees reliable cooling, as it is not
influenced by ambient temperature.
› Maximum piping length up to 50m, minimum piping length has
no limitation
SKY AIR
› Outdoor units for pair, twin, triple, double twin application RZASG100-140MV(1)/MY(1)
ROOFTOP
VRV
Pair, twin, triple and double twin application
AIR PURIFICATION
VENTILATION &
capacity class 35 50 60 71 100 125 140 35 50 60 35 50 60 35 50 60 71 100 125 140
COMMERCIAL
RZASG71MV1 2 P 2 2 2 P
RZASG100MV(1) RZASG100MY(1) 3 2 P 3 2 3 2 3 2 P
RZASG125MV(1) RZASG125MY(1) 4 3 2 P 4 3 2 4 3 2 4 3 2 P
RZASG140MV(1) RZASG140MY(1) 4 3 2 P 4 3 4 3 4 3 2 P
INDUSTRY
MARINE
capacity class 125 35 50 60 71 100 125 140 71 100 125 71 100 71 100 125 140 35 50 60
RZASG71MV1 2 P P P P 2
RZASG100MV(1) RZASG100MY(1) 3 2 P P P P 3 2
RZASG125MV(1) RZASG125MY(1) P 4 3 2 P P P 4 3 2
RZASG140MV(1) RZASG140MY(1) 4 3 2 P 2 2 2 P 4 3
P = Pair, 2 = Twin, 3 = Triple, 4 = Double twin
CHILLERS
More details and final information
can be found by scanning or
clicking the QR codes. RZASG-MV1 RZASG-MY1 RZASG-MV RZASG-MY
FAN COIL
UNITS
Outdoor unit RZASG 71MV1 100MV(1) 125MV(1) 140MV(1) 100MY(1) 125MY(1) 140MY(1)
Dimensions Unit HeightxWidthxDepth mm 770x900x320 990x940x320
Weight Unit kg 60 70 (MY1) / 72 (MY) 78 (MV1) / 79 (MV) 70 (MY1) / 72 (MY) 78 (MV1) / 79 (MV)
Sound power level Cooling dBA 65 70 71 73 70 71 73
Heating dBA - 71(1) 73(1) - 71(1) 73(1)
AIR HANDLING
Piping OU - IU Max. m 50
length System Equivalent m 70
Chargeless m 30
Additional refrigerant charge kg/m See installation manual
Level difference IU - OU Max. m 30.0
Power supply Phase/Frequency/Voltage Hz/V 1~/50 /220-240 3~/50 /380-415
Current - 50Hz Maximum fuse amps (MFA) A 20 25 32 16
CONTROL
SYSTEMS
451
RZA-D
452
INTRODUCTION
ARXM-R / AZAS-MV / MY
RESIDENTIAL
INDOOR AIR
QUALITY
Ideal solution for busy environments and small shops
› High efficiency:
- Energy labels up to A+ (cooling) / A (heating)
HEATING
- compressor offers substantial efficiency improvements
› Choosing for an R-32 product, reduces the environmental impact
with 68% compared to R-410A and leads directly to lower energy
consumption thanks to its high energy efficiency
› Very compact and easy to install
› Replace existing systems with R-32 technology without needing to
SPLIT
replace the piping
SKY AIR
› Guarantees operation in heating mode down to -15°C and in AZAS100-140MV_MY
cooling mode down to -10°C
› Refrigerant cooled PCB guarantees reliable cooling, as it is not
influenced by ambient temperature.
› Piping length up to 30m
ROOFTOP
› Exclusively offered for pair applications
VRV
AIR PURIFICATION
VENTILATION &
COMMERCIAL
Pair application
NEW NEW
FCAG-B FBA-A(9) FAA-B FHA-A(9) FVA-A ADEA-A
capacity class 71 100 125 140 71 100 125 140 71 100 125 140 71 100 125 140 71 100 125 140 71 100 125
INDUSTRY
ARXM-R P P P P
MARINE
AZAS-MV P P P P P P P P P P P P P P P
AZAS-MY P P P P P P P P P P P P P
P = pair application
CHILLERS
More details and final informa-
tion can be found by scanning
or clicking the QR codes. ARXM-R AZAS-MV AZAS-MY
FAN COIL
Piping OU - IU Max. m 30
TRANSPORT
453
Options - Sky Air
FCAHG-H
FFA-A9 FDXM-F9 FBA-A(9)
FCAG-B
INDOOR UNITS
Standard panels:
BYCQ140E (white) /
BYFQ60C2W1W
BYCQ140EW (full white)(1) /
(white panel)
BYCQ140EB (black)
Decoration panel BYFQ60C2W1S
Auto cleaning panels(2)
(obligatory for cassette units, optional for others) (grey panel)
(4): BYCQ140EGF (white) /
BYFQ60B3W1
BYCQ140EGFB (black)
(standard panel)
Panels
BRC1E53A/B/C (3) (13) - Wired remote controller with full-text interface and back-light
DIII-net connection - for connection to centralized control standard standard standard standard
Centralised
systems
control
Standard protocol interfaces
(BAF552AA160-5:
High efficiency filter
box of 5 filters)
(BAF552AA160-10:
box of 10 filters)
Filter chamber
Extension wire auto cleaning panel
Wiring and
sensors
(required when auto cleaning panel AND Onecta app are both installed)
KRCS - External wired temperature sensor KRCS01-5B KRCS01-4 KRCS01-4 KRCS01-4
SB.K.RSS_RFC
K.RSS - External wireless temperature sensor
(EKEWTSC-2 + K.RSS)
Wiring adapter with 2 output signals
KRP1BA58 (10)(11) KRP1B57 (10) KRP1B56 (10)
(compressor/ Error, Fan output)
Wiring and sensors Adapters
KDDP55C160-1 (chamber)
Fresh air intake kit (direct installation type) KDDQ44XA60
KDDP55D160-2 (diffuser) (11)
KDAP25A56A (35-50)
Air discharge adapter for round duct KDAP25A71A (60-71)
KDAP25A140A (100-140)
(1) Dirt formation is more easily visible on white insulation. It is recommended not to install this (4) T he option is intended exclusively for use in fine dust enviornments (e.g. Clothing shops).
option in environments with a high concentration of dirt. Do not use it in environments that are greasy or have high humidity. F = finer mesh
(2) To be able to control option BYCQ140EG(F)/EGFB, controller BRC1H*, BRC1E* is needed. These (5) Sensing function is not available
options cannot be combined with RXYSQ*, multi or non-inverter split units (6) Individual flap control function not available
(3) Included languages are: (7) If installing an electrical heater, an option PCB for external electrical heater (EKRP1B2) for
A: English, German, French, Dutch, Spanish, Italian and Portuguese each indoor unit is required. These options require mounting plate KRP4A96. Electrical
B: English, Bulgarian, Croatian, Czech, Hungarian, Romanian and Slovenian heaters and humidifiers are field-supplied. Do not install them inside the equipment.
C: English, Greek, Polish, Russian, Albanian, Slovak and Turkish (8) Mounting plate KRP4A96 is required for these options. Maximum 2 option PCB’s can be
mounted.
(9) This option cannot be used with RR and RQ models
454
INTRODUCTION
FDA125A FDA200-250A ADEA-A FAA-B FTXM-R FHA-A(9) FUA-A FVA-A FNA-A9
RESIDENTIAL
INDOOR AIR
QUALITY
BYBS125D (19) KDBTP49B140
HEATING
KDBHP49B140
BRP069C81 (18) BRP069C82 (20) BRP069C81 (18) BRP069C81 (18) Integrated in PCB BRP069C81 (18) BRP069C81 (18) BRP069C81 (18) BRP069C81 (18)
SPLIT
BRC4C65 BRC4C65 BRC4C65 ARC466A67 BRC7GA53-9 BRC7C58 BRC4C65
BRC7EA632 (100 class)
(BRC073A1)
BRCW901A03/A08
SKY AIR
extention cords
available (15)
standard standard standard standard KRP928BB2S (15) standard standard standard standard
(15)
(15)
(15)
(15)
ROOFTOP
(15)
(15)
(15)
(KLIC-DDV3) (15)
(15)
(15)
(15)
(15)
(15)
VRV
(15)
(15)
AIR PURIFICATION
VENTILATION &
COMMERCIAL
KAF501B56 (35-50)
BAFL502A250 (20) KAF501B80 (60-71) KAF5511D160 KAFJ95L160
INDUSTRY
KAF501B160 (100-140)
MARINE
BDD500B250
CHILLERS
KRP1C64 (8) KRP1C65 KRP1B54 KRP1B54 (10)
EKRP1B2 (7) EKRP1C13 EKRP1B2 (7) KRP1B56
BRP7A54 (8) BRP7A54 BRP7A51 (12) BRP7A51 (10) BRP7A52 (10) BRP7A53 (10) BRP7A52 (10)
UNITS
KHFP5MA35 (35)
UNITS
KHFP5N63 (50-60)
KHFP5N160 (71-140)
KDAP25A56A (35-50)
KDAJ25K140A KDAP25A71A (60-71)
REFRIGERATION
COMMERCIAL &
KDAP25A140A (100-140)
TRANSPORT
(10) Requires installation box for adapter PCB, refer to table for model code (19) For directly mounting the decoration panel on the unit, decoration panel option EKBYBSD is
(11) This option cannot be combined with BYCQ140EG(F)/EGFB required.
(12) Maximum 2 optional PCBs can be mounted (20) This option cannot be combined with KRP4A51 and KRP2A51. (in case of filter, filter chamber
(13) Applicable boxes (KJB*) to mount controllers can be found in the controls option list is required)
(14) Extention wire (EWHAR1) is needed if both auto cleaning panel AND Onecta app are connected (21) Mounting plate KKSAP50A56 needed for 35-50 capacity class
(15) Wire harness EKRS21 needed. Standard Wireless LAN needs to be turned off to use these (22) Only possible in combination with BYCQ140E and BYCQ140EW. Cannot be combined with
controllers other filters, chambers, fresh air intake kits or air discharge outlet sealing member kit
(16) The active airflow circulation function is not available for this controller (23) Only possible in combination with BYCQ140E/EW/EB. Cannot be combined with other filters,
CONTROL
SYSTEMS
(17) This option cannot be combined with Onecta app chambers, fresh air intake kits or discharge outlet sealing member kit
(18) Only possible in combination with wired or wireless remote control
455
Options - Sky Air
R-32
RZAG-A RZAG-NV1/NY1 RZASG-MV(1)/MY(1) RZA-D AZAS-MV/MY
KHRQ22M20TA
for twin KHRQ58T (imperial size) KHRQ58T (imperial size)
(imperial size)
Refrigerant branch
Liquid GAS
ASYCPIR
ø 9.52 ø 6.4 ø 12.7 ø 9.52 ø 15.9 ø 12.7
FDXM50F9
FFA50A9
FBA50A9
RZAG35A FCAG50B
FNA50A9
FTXM50R
FHA50A9
FBA71A9
FCAG71B
RZAG60A
FTXM71R
FHA71A9
Example of using:
1) Connecting a pipe of ø12.7 to a gas pipe connection port for ø15.9:
456