05 ECPEN24-500A Sky Air

Download as pdf or txt
Download as pdf or txt
You are on page 1of 70

2024

NEW

A update

Sky Air
Light commercial
applications
NEW Round flow cassette with UV Streamer kit

Pure air
because we care

Breathe healthy air with the round flow


UV Streamer kit
90% of our time is spent indoors.
However indoor air is 2 to 5 times
more polluted than outdoor air. BAEF125AWB
These internal pollution effects on people are manifested in the long run. Tackle them now!
Our UV streamer kit offers you the solution:
› It purifies the air of pollutants such as viruses, bacteria, fine dust (PM1), odours, allergens, etc
ensuring a healthy and hygenic indoor environment
› Unique catch & clean approach includes an ISO ePM1 60% (F7) filter, UV-C light and Streamer technology
› Thanks to large air flow rate of the Round flow cassette, clean air can be quickly delivered to every
corner of your space
› Can be retrofitted into existing installations
› Can be used with BYCQ140E and BYCQ140EW decoration panels

Tested at Intertek
Results based on tests performed in
the laboratories of Intertek, in a 28m³ room.

99.9%
Daikin’s Round flow cassette (FXFQ125B)
removes more than 99.9% of enveloped
viruses such as Corona viruses.
of viruses removed in 30 minutes, * Additional details regarding this function can be found

thanks to Daikin’s unique in the unit technical manual.

Catch & Clean approach


Tested according to
real life sized room View full
28m3 test report:

388
INTRODUCTION
Sky Air the solution for the light

RESIDENTIAL
INDOOR AIR
commercial sector

QUALITY
Sky Air is Daikin’s industry-leading light commercial range, which has been designed for optimum

HEATING
seasonal energy efficiency. Providing the ideal solution for all kinds of small commercial spaces, the
Sky Air series offers a complete comfort solution that puts you in total control of your heating and
cooling, ventilation and air curtains.

SPLIT
SKY AIR
Sky Air
Light commercial

ROOFTOP
Wall mounted units 425

applications FAA-B425
FTXM-R428
Ceiling suspended units 429
NEW
combinations FHA-A(9)429

VRV
UNIQUE FUA-A433
Floor standing units 435
NEW
New Sky Air low height series 390 combinations FVA-A435

AIR PURIFICATION
VENTILATION &
Concealed floor standing units 438

COMMERCIAL
Low sound enclosure 391
FNA-A9438
Why choose a Daikin Sky Air 392
Biddle air curtains 440
In the spotlight 394
NEW Biddle air curtain for ERQ 441

Indoor units 396

INDUSTRY
MARINE
Outdoor units 443
Products overview indoor units 396
Products overview outdoor units 444
Benefits overview indoor units 398
Benefits overview outdoor units 445
Ceiling mounted cassettes 402
UV Streamer kit 402 Why choose 446

CHILLERS
NEW
UNIQUE FCAHG-H405 range 450
UNIQUE FCAG-B406
UNIQUE FFA-A9410 RZAG-A 450
Concealed ceiling units 414 RZAG-NV1/NY1 450
FAN COIL

UNIQUE Auto cleaning filter for concealed ceiling units 414


UNITS

RZASG-MV(1)/MY(1) 451
Multi zoning kit 415
FDXM-F9416 RZA-D 452
FBA-A(9)418
ARXM-R/
FDA125A422
AIR HANDLING

AZAS-MV/MY 453
FDA200-250A423
UNITS

ADEA-A424 Options & Accessories 454


REFRIGERATION
COMMERCIAL &
TRANSPORT
CONTROL
SYSTEMS

389
Low height.
High value.

Unique, low-height
single fan range

Compact unit, 1,100 mm

easy to transport
870 mm

Market-leading
serviceability
and handling

Fast and easy access to all Newly positioned handle


critical component for easier carrying
› Single screw access
› Wider access area

390
INTRODUCTION
RESIDENTIAL
INDOOR AIR
QUALITY
HEATING
The smart way for

sound

SPLIT
reduction

SKY AIR
ROOFTOP
VRV
AIR PURIFICATION
VENTILATION &
COMMERCIAL
INDUSTRY
MARINE
– 10 dB(A)!

CHILLERS
Daikin dedicated solution for sound reduction
Meet strict sound requirements, while increasing flexiblity to apply Sky Air
and VRV heat pumps thanks to sound power reduction of up to 10 dB(A).

› Guaranteed high performance: optimised design to keep the capacity


FAN COIL
UNITS

and air flow as close as possible to the standard conditions


› Faster and reliable planning: no calculations or estimations necessary
thanks to tested data according to ISO 3744
› Perfect fit: specially designed for Sky Air and VRV heat pumps
› Maximum flexibility: can be installed and retrofitted on any plain surface
AIR HANDLING

› Easy access: simple and fast installation and maintenance through large
UNITS

side panels with fast locks


› Designed to be discreet: tailor-made low height design; highly aesthetic
finishing and smooth surface in anthracite colour-tone
REFRIGERATION
COMMERCIAL &
TRANSPORT

www.daikin.eu/en_us/products/ekln-a.html
CONTROL
SYSTEMS

391
7 reasons why Sky Air is
unique in
the market
1 Full Sky Air R-32 range delivering future-proofed,
best-in-class climate control

More details
on page 444

Product
System Type Model 35 50 60 71 100 125 140 200 250
name
3.5 kW 5.0 kW 6.0 kW 6.8 kW 9.5 kW 12.1 kW 13.4 kW 21.5 kW 23.6 kW

- Industry leading technology for commercial applications RZAG-A


- Dedicated solution for infrastructure cooling (A+++ - D) RZAG-
- Variable Refrigerant Temperature (RZAG71-100-125-140 series) NV1/NY1
- Maximum piping length up to 85m (50m for RZAG35-50-60)
- Replacement technology
- Extended operation range down to -20°C in both heating and cooling
- Pair, twin, triple and double twin application (RZAG71-100-125-140 series)

RZASG-
MV(1)/
Air Heat MY(1)
cooled pump - Technology and comfort combined for commercial applications
- Very compact and easy to install outdoor units (A+++ - D)
- Maximum piping length up to 50m (RZA-D up to 100m)
- Replacement technology
- Operation range down to -15°C both cooling and in heating (RZA-D down to -20°C) RZA-D
- Pair, twin, triple and double twin application

- Ideal solution for busy environments and small shops ARXM-R


- Very compact and easy to install outdoor units AZAS-
- Maximum piping length up to 30m
(A+++ - D) MV/MY
- Replacement technology
- Easy-to-mount outdoor units: roof, terrace or wall
- Exclusively offered for pair applications

Full indoor line up


(over 45 different models)

392
INTRODUCTION
RESIDENTIAL
INDOOR AIR
2 High energy efficiency 3 Best comfort

QUALITY
› Top seasonal efficiency › Variable Refrigerant Temperature preventing
› SEER up to 8.02 and A++ label in cooling and heating cold draughts
› Variable Refrigerant Temperature that automatically › Low sound indoor and outdoor units

HEATING
adapts the refrigerant temperature to the load › Presence and floor sensors direct the air flow away from
› Round flow and concealed ceiling units with auto persons, while ensuring an even temperature distribution
cleaning filter › Operation down to -20°C in heating and cooling
operation
NEW › UV Streamer kit, purifies the air of pollutants such as
viruses, bacteria, fine dust (PM1), odours, allergens, etc

SPLIT
› Fresh air intake integrated in indoor unit

SKY AIR
presence sensor
floor sensor

ROOFTOP
4 Top reliability 5 Market leading controls
› For infrastructure cooling › Remote connectivity
› unique boosted capacity indoor unit systems › Intuitive app control
› duty rotation control › Daikin Cloud Plus offering online control, energy
› Refrigerant cooled PCB monitoring and comparison of multiple sites

VRV
› New refrigerant passes keeping heat exchanger › User-friendly wired remote controller
and drain holes completely open at all times with premium design
› Most extensive testing before new units leave › Intuitive touch button control

AIR PURIFICATION
the factory › 3 color versions

VENTILATION &
COMMERCIAL
› Widest support network and after sales service › Advanced settings can be easily done
› All spare parts available in Europe via your smartphone
› Dedicated control solutions
› for retail applications
› for infrastructure cooling

INDUSTRY
MARINE
bottom plate refrigerant pass

CHILLERS

6 Superior aesthetics 7 Unique installation benefits


FAN COIL
UNITS

› Fully flat cassette design unit that integrates › 4-way blow ceiling suspended cassette (FUA)
fully flat into the ceiling for rooms without false ceiling.
› Auto cleaning units ensure dirt-free ceilings with high › Plug & play Daikin air handling unit with ERQ condensing
efficiency filters for regular and dust prone areas units
› Widest ever range cassette panels › Reliably replace Daikin and non-Daikin systems without
AIR HANDLING

› Available in white and black the need for pipe cleaning thanks to the new hepta filtration
UNITS

› Sleek designer panel range › Dedicated low sound enclosure, reducing sound power up
to -10 dB(A)
› Use up to 4 indoor units linked to one outdoor unit for
long or irregularly shaped rooms
REFRIGERATION
COMMERCIAL &
TRANSPORT
CONTROL
SYSTEMS

393
Always in control,
no matter where you are

Daikin Cloud Plus


Daikin Cloud Plus is a cloud-based remote control and monitoring solution for Daikin commercial
HVAC installations. Using enhanced control, monitoring and predictive logic, Daikin Cloud
Plus provides real-time data and support from Daikin experts to help you identify cost-saving
opportunities, increase the lifetime of your equipment and reduce the risk of unexpected issues.

The ultimate control Supporting your


over your indoor climate business and helping
and air quality you succeed
› Save energy & reduce costs › Maximize comfort and satisfaction of your staff, customers,
› Enhance comfort & satisfaction tenants, …
› Smart control from anywhere › Save energy & reduce costs
› Ensure healthy indoor environment › Facilitate your sustainability goals
› Maximize uptime (remote prediction, › Cost effective control and energy monitoring of HVAC and other
monitor & diagnose) facility systems such as lighting
› Integrates easily with building systems › Limits the necessity for on-site interventions
› Minimizes downtime and engineer call outs

Dashboard to easily access multiple From one to ∞ sites


locations, energy consumption follow up, …

LOCAL
CONTROL

More details
on page 944 Installer/
Customer technical manager

394
INTRODUCTION
RESIDENTIAL
INDOOR AIR
QUALITY
HEATING
Infrastructure
cooling

SPLIT
SKY AIR
Infrastructure cooling

ROOFTOP
› For rooms and enclosures that require round-the-clock cooling
› Where continuous uptime is the absolute requirement for server data protection Between
20-40%
sensible
capacity

VRV
increase
RELIABLE EFFICIENT FLEXIBLE

AIR PURIFICATION
Guaranteed system operation: Optimum return on investment: › Scalable in capacity

VENTILATION &
COMMERCIAL
› Oversized indoor units boost cooling › Lowers running costs by using › Improved infrastructure control
capacity and prevent freeze-ups on highly efficient direct expansion and management
the indoor side cooling systems › Lower physical footprint since
› Wide operating range envelope: opera- › Lower running costs compared to other no floor space is occupied
tion range in cooling down DX systems and water based chillers. › Wide range of indoor units to suit
to -20°C and up to +52°C › Reduces mechanical cooling and energy application preferences (ceiling

INDUSTRY
MARINE
consumption with the free cooling suspended cassettes, wall mounted
option for single phase systems indoors, concealed ceiling ducted
type indoors)

CHILLERS
Duty rotation application example
SYSTEM 1 FBA140 IN OPERATION SYSTEM 1 FBA140 STANDBY
SYSTEM 2 FBA140 STANDBY
FAN COIL

SYSTEM 2 FBA140 IN OPERATION


UNITS
AIR HANDLING
UNITS

BRC1H* or BRC1E*
Standard includes duty
REFRIGERATION
COMMERCIAL &
TRANSPORT

rotation functionality

RZAG100
RZAG100
CONTROL
SYSTEMS

395
Indoor units

Product overview

Product
Type Model PG
name

360° air discharge for the highest efficiency and comfort


- High COP cassette ensures top performance for commercial applications
UNIQUE UV
- Auto cleaning function ensures high efficiency
High COP, Streamer FCAHG-H 405
- Intelligent sensors save energy and maximize comfort
Round flow cassette kit
- Flexibility to suit every room layout
- Widest choice ever in decoration panel designs and colors
360° air discharge for the highest efficiency and comfort
Ceiling - Auto cleaning function ensures high efficiency
UV
mounted
UNIQUE Streamer FCAG-B 406
- Intelligent sensors save energy and maximize comfort
Round flow cassette - Flexibility to suit every room layout
cassette kit
- Lowest installation height in the market
- Widest choice ever in decoration panel designs and colors
Unique design in the market that integrates fully flat into the ceiling
UNIQUE - Perfect integration in standard architectural ceiling tiles
- Blend of iconic design and engineering excellence with a white or silver and white finish
Fully flat cassette FFA-A9 410
- Intelligent sensors save energy and maximize comfort
- Flexibility to suit every room layout without changing the location of the unit!
- Quietest 600 x 600 cassette on the market
Slim design for flexible installation
Auto Multi - Compact dimensions enable installation in narrow ceiling voids
Slim concealed
ceiling unit
cleaning zoning FDXM-F9 416 - Medium external static pressure up to 40Pa
option option - Small capacity unit developed for small of well insulated rooms
- Auto cleaning function ensures high efficiency and reliability

Slimmest yet most powerfull medium static pressure unit on the market!
- Slimmest unit in class, only 245mm
Multi - Low operating sound level
Concealed ceiling unit
with medium ESP
zoning FBA-A(9) 418 - Medium external static pressure up to 150Pa facilitates using flexible ducts of
option varying lengths
- Automatic air flow adjustment function measures the air volume and static pressure
and adjusts it towards the nominal air flow, guaranteeing comfort
ESP up to 200Pa, ideal for large sized buildings
Concealed - Discretely concealed in the ceiling: only the grilles are visible
ceiling 422 - Possibility to change ESP via wired remote control allows optimisation of the supply
air volume
FDA125A - Flexible installation as the air suction direction can be altered from rear to bottom suction
Concealed ceiling unit with high ESP FDA-A
ESP up to 250Pa, Ideal for extra large sized spaces
- Discretely concealed in the ceiling: only the grilles are visible
423
- Possibility to change ESP via wired remote control allows optimisation of the supply
air volume
FDA200-250A
Ideal for residential applications with false ceilings
- Energy label up to A
Multi
Concealed ceiling unit ADEA-A 424 - Medium external static pressure up to 150Pa facilitates using flexible ducts of
zoning
varying lengths
option
- Slimmest unit in class, only 245mm
- Exclusively offered for pair applications
For rooms with no false ceilings nor free floor space
- Flat, stylish front panel
Wall mounted unit FAA-B 425 - The air is comfortably spread up- and downwards thanks to 5 different discharge angles
- Easy maintenance as this can be done from the front of the unit
Wall - Flexible to install: pipe connection can be bottom, left or right
mounted For rooms with no false ceilings nor free floor space
- Practically inaudible
Perfera wall mounted unit FTXM-R 428 - 2 area motion detection sensor
- Flash streamer technology
- 3D air flow
For wide rooms with no false ceilings nor free floor space
- Ideal for comfortable air flow in wide rooms thanks to Coanda effect
Ceiling suspended unit FHA-A(9) 429
- Even rooms with ceilings up to 3.8m can be heated up or cooled down very easily!
- Can be mounted in corners or narrow spaces without any problem
Ceiling
suspended Unique Daikin unit for high rooms with no false ceilings nor free floor space
- Even rooms with ceilings up to 3.5m can be heated up or cooled down very easily!
UNIQUE FUA-A 433 - Flexibility to suit every room layout without changing the location of the unit!
4-way blow ceiling suspended unit - Optimum comfort guaranteed with automatic air flow adjustment to the required load
- The air is comfortably spread up- and downwards thanks to 5 different discharge angles
For spaces with high ceilings
- Ideal solution for commercial spaces with no or narrow false ceilings
Floor standing unit FVA-A 435 - Even rooms with very high ceilings can be heated up or cooled down very easily!
- Guarantees a stable temperature
Floor - Vertical and horizontal outblow
standing
Designed to be concealed in walls, only grilles remain visible
- Slimmest unit on the market with a depth of only 200mm!
Concealed floor standing unit FNA-A9 438
- Both window sill or ducted installation are possible thanks to sufficient ESP
- Whisper quiet operation allows installation in any location

396
INTRODUCTION
Full R-32 Indoor units

FULL
line up single fan

RESIDENTIAL
INDOOR AIR
range

QUALITY
Outdoor unit combination
Capacity class

25 35 50 60 71 100 125 140 200 250

HEATING
RZAG- RZASG- AZAS-
RZAG-A RZA-D ARXM-R
NV1/NY1 MV(1)/MY(1) MV/MY

• • • • 

SPLIT
• • • • • • •      

SKY AIR
• • • •    

• • • •    

ROOFTOP
• • • • • • •      

VRV
•   

AIR PURIFICATION
VENTILATION &
COMMERCIAL
• • 

• • •  

INDUSTRY
MARINE
• •     

• • •  CHILLERS

NEW
• • • • • • •    

FAN COIL
UNITS

• • •   
AIR HANDLING
UNITS

NEW
• • • •   

• • • •    
REFRIGERATION
COMMERCIAL &
TRANSPORT
CONTROL
SYSTEMS

397
Indoor units

Benefit overview

Home leave Maintains the indoor temperature at your specified comfort level during absence, thus saving energy.
operation
Fan only The unit can be used as fan, blowing air without heating or cooling.
We care

The filter automatically cleans itself. Simplicity of upkeep means optimum energy efficiency and maximum comfort without
Auto cleaning filter
the need for expensive or time-consuming maintenance.
The presence sensor directs the air away from any person detected in the room, when the air flow control is on.
Presence & floor The floor sensor detects the average floor temperature and ensures an even temperature distribution between ceiling and
sensor
floor.

When starting to warm up or when the thermostat is off, the air discharge direction is set horizontally
Draught prevention
and the fan to low speed, to prevent draught. After warming up, air discharge and fan speed are set as desired.
Comfort

Daikin indoor units are whisper quiet. Also the outdoor units are guaranteed
Whisper quiet
not to disturb the quiet of the neightbourhood.
Auto cooling- Automatically selects cooling or heating mode to achieve the set temperature.
heating changeover

NEW Purifies the air of pollutants such as viruses, bacteria, fine dust, odours, allergens, etc ensuring a healthy and hygienic indoor
UV Streamer kit environment
Air treatment

Air filter Removes airborne dust particles to ensure a steady supply of clean air.
Humidity
control

Dry programme Allows humidity levels to be reduced without variations in room temperature.

Ceiling soiling Prevents air from blowing out too long in horizontal position, to prevent ceiling stains.
prevention

Vertical auto swing Possibility to select automatic vertical moving of the air discharge louvre, for uniform air flow and temperature distribution.
Air flow

Fan speed steps Allows to select up to the given number of fan speed.

Individual flap Individual flap control via the wired remote controller enables you to easily fix the position of each flap individually,
control to suit any new room configuration. Optional closure kits are available as well.

Onecta app Control your indoor climate from any location via smartphone or tablet.
Remote control & timer

Weekly timer Can be set to start heating or cooling anytime on a daily or weekly basis.
Infrared remote Starts, stops and regulates the air conditioner from a distance.
control
Wired remote Starts, stops and regulates the air conditioner.
control
Centralised control Starts, stops and regulates several air conditioners from one central point.

Multi zoning Allows up to 6 individual climate zones with one indoor unit

Infrastructure Remove in a reliable, efficient and flexible way the heat constantly generated by the IT and server equipment to ensure
cooling maximum uptime while offering the best return on investment.
Auto-restart The unit restarts automatically at the original settings after power failure.

Self-diagnosis Simplifies maintenance by indicating system faults or operating anomalies.


Other functions

Drain pump kit Facilitates condensation draining from the indoor unit.

Twin/triple/double 2, 3 or 4 indoor units can be connected to only a single outdoor unit even if they have different capacities. All indoor units
twin application operate within the same heating or cooling mode from one remote control.
Multi model Up to 5 indoor units can be connected to a single outdoor unit, even if they have different capacities. All indoor units can
application individually be operated within the same heating or cooling mode.
VRV for residential Up to 9 indoor units (even different capacities and up to 71 class) can be connected to a single outdoor unit.
application All indoor units can individually be operated within the same mode.

398
INTRODUCTION
Indoor units
4-Way blow
Ceiling mounted Ceiling Wall Perfera wall Floor
Concealed ceiling ceiling
cassette suspended mounted mounted standing
units suspended
units units unit unit units

RESIDENTIAL
unit

INDOOR AIR
QUALITY
F C A HG - H FC AG -B FFA-A9 FDXM - F9 FB A- A(9) FDA125A FDA2 00- 250A A DE A - A F H A - A ( 9) FUA-A FAA-B F T XM - R FVA-A F NA - A 9

HEATING
• • • • • • • • • • • • •
• • • • • • • • • • • • • •
• • •

SPLIT
• • •

• • • •

SKY AIR
• • • • • •
• • • • • • • • • • • • • •

ROOFTOP
• •
• •
(Optional high
efficiency filter • • • • • • • • • • (Flash streamer;
titanium apatite
deodorising
• •
ePM10 60%) filter)

VRV
• • • • • • • • • • • • • •

AIR PURIFICATION
VENTILATION &
COMMERCIAL
• • •
• • • • • • •
(incl. 3D •
air flow)

INDUSTRY
5 + auto 5 + auto 3 + auto 3 3 + auto 9 + auto 3 + auto 3 + auto 5 + auto 3 + auto 3 + auto 5 + auto 3 + auto 3 + auto

MARINE
• • • •

• • • • • • • • • • • • • •
CHILLERS
• • • • • • • • • • • • • •
• • • • • • • • • • • • •
• • • • • • • • • • • • • •
FAN COIL

• • • • • • • • • • • • • •
UNITS

• • •
AIR HANDLING

• • • • • • • • • • • • •
UNITS

• • • • • • • • • • • • • •
• • • • • • • • • • • • • •
• • • • • • • • • •
REFRIGERATION
COMMERCIAL &
TRANSPORT

• • • • • • • • • • •
• • • • • •
• • • • • •
CONTROL
SYSTEMS

• standard, • optional
399
Sky Air

FULLY FLAT CASSETTE CONCEALED CEILING UNIT

CONCEALED FLOOR 4-WAY BLOW CEILING


STANDING UNIT SUSPENDED CASSETTE

400
WALL MOUNTED UNIT

ROUND FLOW CASSETTE, DESIGNER PANEL


CEILING SUSPENDED UNIT
Sky Air

401
COMMERCIAL & COMMERCIAL RESIDENTIAL
CONTROL AIR HANDLING FAN COIL MARINE
TRANSPORT CHILLERS VENTILATION & VRV ROOFTOP SKY AIR SPLIT HEATING INDOOR AIR INTRODUCTION
SYSTEMS UNITS UNITS INDUSTRY
REFRIGERATION AIR PURIFICATION QUALITY
NEW Round flow cassette with UV Streamer kit

Pure air
because we care

Breathe healthy air with the round flow


UV Streamer kit
90% of our time is spent indoors.
However indoor air is 2 to 5 times
more polluted than outdoor air. BAEF125AWB
These internal pollution effects on people are manifested in the long run. Tackle them now!
Our UV streamer kit offers you the solution:
› It purifies the air of pollutants such as viruses, bacteria, fine dust (PM1), odours, allergens, etc
ensuring a healthy and hygenic indoor environment
› Unique catch & clean approach includes an ISO ePM1 60% (F7) filter, UV-C light and Streamer technology
› Thanks to large air flow rate of the Round flow cassette, clean air can be quickly delivered to every
corner of your space
› Can be retrofitted into existing installations
› Can be used with BYCQ140E and BYCQ140EW decoration panels

Tested at Intertek
Results based on tests performed in
the laboratories of Intertek, in a 28m³ room.

99.9%
Daikin’s Round flow cassette (FXFQ125B)
removes more than 99.9% of enveloped
viruses such as Corona viruses.
of viruses removed in 30 minutes, * Additional details regarding this function can be found

thanks to Daikin’s unique in the unit technical manual.

Catch & Clean approach


Tested according to
real life sized room View full
28m3 test report:

402
INTRODUCTION
RESIDENTIAL
INDOOR AIR
QUALITY
Daikin’s unique Catch & Clean approach includes an

HEATING
ePM1 50% filter, UV-C light and Streamer technology

SPLIT
2 Effective cleaning and decomposition
of pollutants
1 Effective capturing of air
Our unique combined UV-C light and
borne pollutants
› Highly efficient capturing Streamer technology ensures both
particulate matter and surface and in-depth sanitising of the
filter to ensure hygienic air.

SKY AIR
pollutants thanks to
the ISO ePM1 60% (F7) filter
› Anti bacterial and viral UVC LED light with high output
coating wavelength of 265nm which is
the most effective for surface cleaning
and inactivation of bacteria and viruses.

ROOFTOP
Indicator light
Indicates operation,
malfunction or replacement status

VRV
AIR PURIFICATION
VENTILATION &
COMMERCIAL
Streamer technology for deep
sanitising of the filter and powerful
decomposition of viruses and
bacteria trapped inside the filter.

INDUSTRY
MARINE
CHILLERS

Specifications
FAN COIL

BAEF125AWB
UNITS

Power Supply 1P, 220-240V, 50/60 Hz


Dimensions HxWxD mm 100 x 840 x 840
Weight kg 12
BYCQ140E/BYCQ140EW *
Compatible decoration panels
AIR HANDLING

(UV-streamer kit cannot be used with other filters, chambers, fresh air intake kits or air discharge outlet sealing member kit)
UNITS

ePM1 60% @ISO16890


Filter efficiency
(F7)
Pleated filter (BAF55A125): every year
Replacement interval Flash streamer device: every 7 years
UV-C LED: every 7 years
REFRIGERATION

* For compatibility with older panels, consult your local sales representative
COMMERCIAL &
TRANSPORT

download
the leaflet here
CONTROL
SYSTEMS

403
Complete indoor
comfort, including
pure air
The round flow cassette
› Maximum comfort thanks to 360° air discharge and intelligent sensors

› Widest ever choice in panels to match any interior


presence floor sensor
sensor

Black auto cleaning panel Black designer panel Full white standard panel White designer panel

› Auto cleaning panel keeps the filter free of dust for maximum efficiency

› UV streamer kit
NEW › Purifies the air of pollutants such as viruses, bacteria, fine dust PM1, odours, allergens, etc ensur-
ing a healthy and hygienic indoor environment
› Unique catch & clean approach includes an ISO ePM1 60% (F7) filter, UV-C light
and Streamer technology
› Can be retrofitted into existing installations

Tested at Intertek
Results based on tests performed in
the laboratories of Intertek, in a 28m³ room.

99.9%
Daikin’s Round flow cassette (FXFQ125B)
removes more than 99.9% of enveloped
viruses such as Corona viruses.
of viruses removed in 30 minutes, * Additional details regarding this function can be found

thanks to Daikin’s unique in the unit technical manual.

Catch & Clean approach


Tested according to
real life sized room View full
28m3 test report:

404
INTRODUCTION
FCAHG-H + RZAG-NV1 / NY1

High COP, round flow cassette

RESIDENTIAL
INDOOR AIR
QUALITY
360° air discharge for optimum efficiency and comfort

› Combination with Sky Air Alpha-series ensures best in class


quality, highest efficiency and performance

HEATING
› High COP cassette ensures top performance and great energy savings
› Optional automatic filter cleaning panel results in higher efficiency
& comfort and lower maintenance costs.
› Individual flap control: flexibility to suit every room layout without FCAHG-H
changing the location of the unit!
› Widest choice ever in decoration panels: designer panels in white

SPLIT
(RAL9010) and black (RAL9005) and standard panels in white
(RAL9010) with grey louvers or full white
› Bigger flaps and unique swing pattern improve equal air distribution
› 5 different fan speeds available for maximum comfort
› UV streamer kit, purifies the air of pollutants such as viruses,

SKY AIR
bacteria, fine dust, odours, allergens, etc ensuring a healthy and RZAG-NV1_NY1 BRC1H52W BRP069C82
hygenic indoor environment
› Optional fresh air intake
› Branch duct discharge allows to optimize air distribution in
irregular shaped rooms or to supply air to small adjacent rooms

ROOFTOP
› Standard drain pump with 675mm lift increases flexibility and
installation speed
White panel White auto cleaning panel Black panel Black design panel

More details and final information


can be found by scanning or
clicking the QR codes. FCAHG-H RZAG-NV1 RZAG-NY1

VRV
Efficiency data FCAHG + RZAG 71H + 71NV1 100H + 100NV1 125H + 125NV1 140H + 140NV1 71H + 71NY1 100H + 100NY1 125H + 125NY1 140H + 140NY1
Cooling capacity Nom. kW 6.80 9.50 12.1 13.4 6.80 9.50 12.1 13.4
Heating capacity Nom. kW 7.50 10.8 13.5 15.5 7.50 10.8 13.5 15.5
Space cooling Energy efficiency class A++ - A++ -

AIR PURIFICATION
VENTILATION &
Capacity Pdesign kW 6.80 9.50 12.1 13.4 6.80 9.50 12.1 13.4

COMMERCIAL
SEER 7.90 7.70 8.02 7.93 7.90 7.70 8.02 7.93
ηs,c % - 318 314 - 318 314
Annual energy consumption kWh/a 301 432 905 1,014 301 432 905 1,014
Space heating Energy efficiency class A++ - A+ A++ -
(Average climate) Capacity Pdesign kW 4.70 9.52 4.70 9.52
SCOP/A 4.61 4.75 4.53 4.44 4.56 4.75 4.53 4.44
ηs,h % - 178 175 - 178 175
Annual energy consumption kWh/a 1,427 2,805 2,943 3,002 1,443 2,805 2,943 3,002

INDUSTRY
MARINE
Indoor unit FCAHG 71H 100H 125H 140H 71H 100H 125H 140H
Dimensions Unit HeightxWidthxDepth mm 288x840x840
Weight Unit kg 25.0
Air filter Type Resin net
Decoration panel Model Standard panels: BYCQ140E - white with grey louvers / BYCQ140EW - full white / BYCQ140EB - black
Auto cleaning panels: BYCQ140EGF - white / BYCQ140EGFB - black
Designer panels: BYCQ140EP - white / BYCQ140EPB - black

CHILLERS
Dimensions HeightxWidthxDepth mm Standard panels: 65x950x950 / Auto cleaning panels: 148x950x950 / Designer panels: 106x950x950
Weight kg Standard panels: 5.5 / Auto cleaning panels: 10.3 / Designer panels: 6.5
Fan Air flow Cooling Low/Medium/High m³/min 13.7/18.8/23.6 19.1/25.7/32.2 21.2/27.3/34.4 13.7/18.8/23.6 19.1/25.7/32.2 21.2/27.3/34.4
rate Heating Low/Medium/High m³/min 13.7/18.8/23.6 18.3/24.6/30.8 19.7/25.5/32.1 13.7/18.8/23.6 18.3/24.6/30.8 19.7/25.5/32.1
Sound power level Cooling dBA 53.0 61.0 53.0 61.0
Heating dBA 53.0 61.0 53.0 61.0
Sound pressure Cooling Low/High dBA 29.0/36.0 33.0/44.0 35.0/45.0 37.0/45.0 29.0/36.0 33.0/44.0 35.0/45.0 37.0/45.0
level Heating Low/High dBA 29.0/36.0 33.0/44.0 35.0/45.0 37.0/45.0 29.0/36.0 33.0/44.0 35.0/45.0 37.0/45.0
FAN COIL
UNITS

Control systems Infrared remote control BRC7FA532F / BRC7FB532F / BRC7FA532FB / BRC7FB532FB


Wired remote control BRC1H52W/S/K / BRC1E53A / BRC1E53B / BRC1E53C / BRC1D52
Power supply Phase/Frequency/Voltage Hz/V 1~/50/60/220-240/220
Piping connections Drain VP25 (I.D. 25/O.D. 32)
Outdoor unit RZAG 71NV1 100NV1 125NV1 140NV1 71NY1 100NY1 125NY1 140NY1
Dimensions Unit HeightxWidthxDepth mm 870x1,100x460
AIR HANDLING

Weight Unit kg 81 85 95 81 85 94
Sound power level Cooling dBA 64 66 69 70 64 66 69 70
UNITS

Heating dBA - 68 71 - 68 71
Sound pressure Cooling Nom. dBA 46 47 49 50 46 47 49 50
level Heating Nom. dBA 48 50 52 48 50 52
Operation range Cooling Ambient Min.~Max. °CDB -20~52
Heating Ambient Min.~Max. °CWB -20~18
REFRIGERATION
COMMERCIAL &

Refrigerant Type/GWP R-32/675


TRANSPORT

Charge kg/TCO2Eq 3.20/2.16 3.70/2.50 3.20/2.16 3.70/2.50


Piping connections Liquid/Gas OD mm 9.52/15.9
Piping OU - IU Max. m 55 85 55 85
length System Equivalent m 75 100 75 100
Chargeless m 40
Level difference IU - OU Max. m 30
Additional refrigerant charge kg/m See installation manual
Power supply Phase/Frequency/Voltage Hz/V 1~/50 /220-240 3~/50 /380-415
CONTROL
SYSTEMS

Current - 50Hz Maximum fuse amps (MFA) A 20 32 16


Contains fluorinated greenhouse gases
405
FCAG-B + RZAG-A / NV1 / NY1

Round flow cassette


360° air discharge for optimum efficiency and comfort

› Combination with Sky Air Alpha-series ensures best in class


quality, highest efficiency and performance
› Optional automatic filter cleaning panel results in higher efficiency
& comfort and lower maintenance costs
› Two optional intelligent sensors improve energy efficiency and comfort
› Individual flap control: flexibility to suit every room layout without FCAG-B
changing the location of the unit!
› Lowest installation height in the market: 214mm for class 20-63
› Widest choice ever in decoration panels: designer panels in white
(RAL9010) and black (RAL9005) and standard panels in white
(RAL9010) with grey louvers or full white
› Bigger flaps and unique swing pattern improve equal air distribution
› UV streamer kit, purifies the air of pollutants such as viruses,
bacteria, fine dust, odours, allergens, etc ensuring a healthy and RZAG-NV1_NY1 BRC1H52W BRP069C82
hygenic indoor environment
› Optional fresh air intake
› Branch duct discharge allows to optimize air distribution in
irregular shaped rooms or to supply air to small adjacent rooms
› Standard drain pump with 675mm lift increases flexibility and
installation speed
White panel White auto cleaning panel Black panel Black design panel

More details and final information


can be found by scanning or
clicking the QR codes. FCAG-B RZAG-A RZAG-NV1 RZAG-NY1
Efficiency data FCAG + RZAG 35B + 35A 50B + 50A 60B + 60A 71B + 71NV1 100B + 100NV1 125B + 125NV1 140B + 140NV1 71B + 71NY1 100B + 100NY1 125B + 125NY1 140B + 140NY1
Cooling capacity Nom. kW 1.6/3.5/4.5 1.7/5.0/6.0 1.7/6.0/6.5 -/6.80/- -/9.50/- -/12.1/- -/13.4/- -/6.80/- -/9.50/- -/12.1/- -/13.4/-
Heating capacity Nom./Max. kW 1.40/4.00/5.00 1.50/5.80/6.00 1.60/7.00/7.50 -/7.50/- -/10.8/- -/13.5/- -/15.5/- -/7.50/- -/10.8/- -/13.5/- -/15.5/-
Space cooling Energy efficiency class A++ - A++ -
Capacity Pdesign kW 3.50 5.00 6.00 6.80 9.50 12.1 13.4 6.80 9.50 12.1 13.4
SEER 7.30 6.80 6.60 6.83 7.14 7.15 6.80 6.83 7.14 7.15 6.80
ηs,c % - 283 269 - 283 269
Annual energy consumption kWh/a 168 257 318 348 466 1,016 1,182 348 466 1,016 1,182
Space heating Energy efficiency class A+ - A+ -
(Average climate) Capacity Pdesign kW 3.30 4.30 4.60 4.70 7.80 9.52 4.70 7.80 9.52
SCOP/A 4.30 4.25 4.22 4.53 4.34 4.22 4.53 4.34
ηs,h % - 171 - 171
Annual energy consumption kWh/a 1,074 1,398 1,515 1,560 2,413 3,071 1,560 2,413 3,071
Indoor unit FCAG 35B 50B 60B 71B 100B 125B 140B 71B 100B 125B 140B
Dimensions Unit HeightxWidthxDepth mm 204x840x840 246x840x840 204x840x840 246x840x840
Weight Unit kg 18 19 21 23 21 23
Air filter Type Resin net
Decoration panel Model Standard panels: BYCQ140E - white with grey louvers / BYCQ140EW - full white / BYCQ140EB - black
Auto cleaning panels: BYCQ140EGF - white / BYCQ140EGFB - black
Designer panels: BYCQ140EP - white / BYCQ140EPB - black
Dimensions HeightxWidthxDepth mm Standard panels: 65x950x950 / Auto cleaning panels: 148x950x950 / Designer panels: 106x950x950
Weight kg Standard panels: 5.5 / Auto cleaning panels: 10.3 / Designer panels: 6.5
Fan Air flow Cooling Low/Medium/High m³/min 8.8/10.6/12.9 9.4/11.8/14.6 9.6/12.2/14.9 10.8/13.0/15.1 13.0/17.8/22.7 13.1/20.4/27.2 10.8/13.0/15.1 13.0/17.8/22.7 13.1/20.4/27.2
rate Heating Low/Medium/High m³/min 9.4/11.6/14.1 9.4/11.8/14.6 9.6/12.2/14.9 10.8/12.9/15.1 13.2/18.1/23.0 13.0/20.2/27.0 10.8/12.9/15.1 13.2/18.1/23.0 13.0/20.2/27.0
Sound power level Cooling dBA 49.0 51.0 54.0 58.0 51.0 54.0 58.0
Heating dBA 49.0 51.0 54.0 58.0 51.0 54.0 58.0
Sound pressure Cooling Low/High dBA 27.0/31.0 28.0/33.0 28.0/35.0 29.0/37.0 29.0/41.0 28.0/35.0 29.0/37.0 29.0/41.0
level Heating Low/High dBA 27.0/31.0 28.0/33.0 29.0/37.0 29.0/41.0 28.0/33.0 29.0/37.0 29.0/41.0
Control systems Infrared remote control BRC7FA532F / BRC7FB532F / BRC7FA532FB / BRC7FB532FB
Wired remote control BRC1H52W/S/K / BRC1E53A / BRC1E53B / BRC1E53C / BRC1D52
Power supply Phase/Frequency/Voltage Hz/V 1~/50/60/220-240/220
Piping connections Drain VP25 (O.D. 32 / I.D. 25)
Outdoor unit RZAG 35A 50A 60A 71NV1 100NV1 125NV1 140NV1 71NY1 100NY1 125NY1 140NY1
Dimensions Unit HeightxWidthxDepth mm 734x870x373 870x1,100x460
Weight Unit kg 52 81 85 95 81 85 94
Sound power level Cooling dBA 62.0 63.0 64.0 64 66 69 70 64 66 69 70
Heating dBA 62.0 63.0 64.0 - 68 71 - 68 71
Sound pressure Cooling Nom. dBA 48.0 49.0 50.0 46 47 49 50 46 47 49 50
level Heating Nom. dBA 48.0 49.0 50.0 48 50 52 48 50 52
Operation range Cooling Ambient Min.~Max. °CDB -20~52 -20~52
Heating Ambient Min.~Max. °CWB -20~24 -20~18
Refrigerant Type/GWP R-32/675.0 R-32/675
Charge kg/TCO2Eq 1.55/1.05 3.20/2.16 3.70/2.50 3.20/2.16 3.70/2.50
Piping connections Liquid/Gas OD mm 6.35/9.52 6.35/12.7 9.52/15.9
Piping OU - IU Max. m 50 55 85 55 85
length System Equivalent m - 75 100 75 100
Chargeless m 30 40
Level difference IU - OU Max. m 30.0 30
Additional refrigerant charge kg/m 0.02 (for piping length exceeding 30m) See installation manual
Power supply Phase/Frequency/Voltage Hz/V 1~/50 /220-240 3~/50 /380-415
Current - 50Hz Maximum fuse amps (MFA) A - 20 32 16
Contains fluorinated greenhouse gases
406
INTRODUCTION
FCAG-B + RZASG-MV(1)/MY(1)

Round flow cassette

RESIDENTIAL
INDOOR AIR
QUALITY
360° air discharge for optimum efficiency and comfort

› Combination with Sky Air Advance-series ensures good value for


money for all types of commercial applications

HEATING
› Optional automatic filter cleaning panel results in higher efficiency
& comfort and lower maintenance costs.
› Two optional intelligent sensors improve energy efficiency and
comfort FCAG-B
› Widest choice ever in decoration panels: designer panels in white
(RAL9010) and black (RAL9005) and standard panels in white

SPLIT
(RAL9010) with grey louvers or full white
› Bigger flaps and unique swing pattern improve equal air distribution
› Individual flap control: flexibility to suit every room layout without
changing the location of the unit!
› UV streamer kit, purifies the air of pollutants such as viruses,

SKY AIR
bacteria, fine dust, odours, allergens, etc ensuring a healthy and RZASG100-140MV(1)/MY(1) BRC1H52W, BRP069C82
hygenic indoor environment
› Optional fresh air intake
› Branch duct discharge allows to optimize air distribution in
irregular shaped rooms or to supply air to small adjacent rooms

ROOFTOP
› Standard drain pump with 675mm lift increases flexibility and
installation speed
White panel White auto cleaning panel Black panel Black design panel
More details and final
information can be
found by scanning or
clicking the QR codes. FCAG-B RZASG-MV1 RZASG-MY1 RZASG-MV RZASG-MY

VRV
Efficiency data FCAG + RZASG 71B + 71MV1 100B + 100MV(1) 125B + 125MV(1) 140B + 140MV(1) 100B + 100MY(1) 125B + 125MY(1) 140B + 140MY(1)
Cooling capacity Nom. kW 6.80 9.50 12.1 13.4 9.50 12.1 13.4
Heating capacity Nom. kW 7.50 10.8 13.5 15.5 10.8 13.5 15.5
Space cooling Energy efficiency class A++ - A++ -

AIR PURIFICATION
VENTILATION &
Capacity Pdesign kW 6.80 9.50 12.1 13.4 9.50 12.1 13.4

COMMERCIAL
SEER 6.47 6.55 5.76 6.53 6.55 5.76 6.53
ηs,c % - 227 258 - 227 258
Annual energy consumption kWh/a 368 507 1,261 1,231 507 1,261 1,231
Space heating Energy efficiency class A+ - A+ -
(Average climate) Capacity Pdesign kW 4.50 6.00 7.80 6.00 7.80
SCOP/A 4.10 4.17 4.05 4.31 4.17 4.05 4.31
ηs,h % - 159 169 - 159 169
Annual energy consumption kWh/a 1,537 2,016 2,074 2,534 2,016 2,074 2,534

INDUSTRY
MARINE
Indoor unit FCAG 71B 100B 125B 140B 100B 125B 140B
Dimensions Unit HeightxWidthxDepth mm 204x840x840 246x840x840
Weight Unit kg 21 23
Air filter Type Resin net
Decoration panel Model Standard panels: BYCQ140E - white with grey louvers / BYCQ140EW - full white / BYCQ140EB - black
Auto cleaning panels: BYCQ140EGF - white / BYCQ140EGFB - black
Designer panels: BYCQ140EP - white / BYCQ140EPB - black

CHILLERS
Dimensions HeightxWidthxDepth mm Standard panels: 65x950x950 / Auto cleaning panels: 148x950x950 / Designer panels: 106x950x950
Weight kg Standard panels: 5.5 / Auto cleaning panels: 10.3 / Designer panels: 6.5
Fan Air flow Cooling Low/Medium/High m³/min 10.8/13.0/15.1 13.0/17.8/22.7 13.1/20.4/27.2 13.0/17.8/22.7 13.1/20.4/27.2
rate Heating Low/Medium/High m³/min 10.8/12.9/15.1 13.2/18.1/23.0 13.0/20.2/27.0 13.2/18.1/23.0 13.0/20.2/27.0
Sound power level Cooling dBA 51.0 54.0 58.0 54.0 58.0
Heating dBA 51.0 54.0 58.0 54.0 58.0
Sound pressure Cooling Low/Medium/High dBA 28.0/31.0/35.0 29.0/33.0/37.0 29.0/35.0/41.0 29.0/33.0/37.0 29.0/35.0/41.0
level Heating Low/Medium/High dBA 28.0/31.0/33.0 29.0/33.0/37.0 29.0/35.0/41.0 29.0/33.0/37.0 29.0/35.0/41.0
FAN COIL
UNITS

Control systems Infrared remote control BRC7FA532F / BRC7FB532F / BRC7FA532FB / BRC7FB532FB


Wired remote control BRC1H52W/S/K / BRC1E53A / BRC1E53B / BRC1E53C / BRC1D52
Power supply Phase/Frequency/Voltage Hz/V 1~/50/60/220-240/220
Outdoor unit RZASG 71MV1 100MV(1) 125MV(1) 140MV(1) 100MY(1) 125MY(1) 140MY(1)
Dimensions Unit HeightxWidthxDepth mm 770x900x320 990x940x320
AIR HANDLING

Weight Unit kg 60 70 (MV1) / 72 (MV) 78 (MV1) / 79 (MV) 70 (MY1) / 72 (MY) 78 (MV1) / 79 (MV)
Sound power level Cooling dBA 65 70 71 73 70 71 73
UNITS

Heating dBA - 71 73 - 71 73
Sound pressure Cooling Nom. dBA 46 53 54 53 54
level Heating Nom. dBA 47 57
Operation range Cooling Ambient Min.~Max. °CDB -15~46
Heating Ambient Min.~Max. °CWB -15~15.5
Refrigerant Type/GWP R-32/675
REFRIGERATION
COMMERCIAL &
TRANSPORT

Charge kg/TCO2Eq 2.45/1.65 2.60/1.76 2.90/1.96 2.60/1.76 2.90/1.96


Piping connections Liquid/Gas OD mm 9.52/15.9
Piping OU - IU Max. m 50
length System Equivalent m 70
Chargeless m 30
Additional refrigerant charge kg/m See installation manual
Level difference IU - OU Max. m 30.0
Power supply Phase/Frequency/Voltage Hz/V 1~/50 /220-240 3~/50 /380-415
CONTROL
SYSTEMS

Current - 50Hz Maximum fuse amps (MFA) A 20 25 32 16


Contains fluorinated greenhouse gases
407
FCAG-B + ARXM-R / AZAS-MV / MY

Round flow cassette


360° air discharge for optimum efficiency and comfort

› Ideal solution for small businesses and shops


› Optional automatic filter cleaning panel results in higher efficiency
& comfort and lower maintenance costs.
› Two optional intelligent sensors improve energy efficiency and
comfort
› Widest choice ever in decoration panels: designer panels in white FCAG-B
(RAL9010) and black (RAL9005) and standard panels in white
(RAL9010) with grey louvers or full white
› Individual flap control: flexibility to suit every room layout without
changing the location of the unit!
› Bigger flaps and unique swing pattern improve equal air
distribution
› UV streamer kit, purifies the air of pollutants such as viruses,
bacteria, fine dust, odours, allergens, etc ensuring a healthy and AZAS100-140MV1_MY1 BRC1H52W, BRP069C82
hygenic indoor environment
› Optional fresh air intake
› Branch duct discharge allows to optimize air distribution in
irregular shaped rooms or to supply air to small adjacent rooms
› Standard drain pump with 675mm lift increases flexibility and
installation speed
White panel White auto cleaning panel Black panel Black design panel

More details and final information


can be found by scanning or
clicking the QR codes. FCAG-B ARXM-R AZAS-MV AZAS-MY
Efficiency data FCAG + ARXM / AZAS 71B + ARXM 71R 100B + AZAS100MV 125B + AZAS125MV 140B + AZAS140MV 100B + AZAS100MY 125B + AZAS125MY 140B + AZAS140MY
Cooling capacity Nom. kW 6.80/7.05 9.50/- 12.1/- 13.4/- 9.50/- 12.1/- 13.4/-
Heating capacity Nom./Max. kW 7.50/7.58 10.8/- 13.5/- 15.5/- 10.8/- 13.5/- 15.5/-
Space cooling Energy efficiency class A+ - A+ -
Capacity Pdesign kW 6.80 9.50 12.1 13.0 9.50 12.1 13.0
SEER 5.87 6.1 5.6 6.2 6.1 5.6 6.2
ηs,c % - 221 245 - 221 245
Annual energy consumption kWh/a 405 586 1,345 1,300 586 1,345 1,300
Space heating Energy efficiency class A+ A - A -
(Average climate) Capacity Pdesign kW 4.50 6.00 7.80 6.00 7.80
SCOP/A 4.00 3.85 3.80 4.31 3.85 3.80 4.31
ηs,h % - 149 169 - 149 169
Annual energy consumption kWh/a 1,573 2,182 2,211 2,534 2,182 2,211 2,534
Indoor unit FCAG 71B 100B 125B
140B 100B 125B 140B
Dimensions Unit HeightxWidthxDepth mm 204x840x840 246x840x840
Weight Unit kg 21 23
Air filter Type Resin net
Decoration panel Model Standard panels: BYCQ140E - white with grey louvers / BYCQ140EW - full white / BYCQ140EB - black
Auto cleaning panels: BYCQ140EGF - white / BYCQ140EGFB - black
Designer panels: BYCQ140EP - white / BYCQ140EPB - black
Dimensions HeightxWidthxDepth mm Standard panels: 65x950x950 / Auto cleaning panels: 148x950x950 / Designer panels: 106x950x950
Weight kg Standard panels: 5.5 / Auto cleaning panels: 10.3 / Designer panels: 6.5
Fan Air flow Cooling Low/Medium/High m³/min 10.8/13.0/15.1 13.0/17.8/22.7 13.1/20.4/27.2 13.0/17.8/22.7 13.1/20.4/27.2
rate Heating Low/Medium/High m³/min 10.8/12.9/15.1 13.2/18.1/23.0 13.0/20.2/27.0 13.2/18.1/23.0 13.0/20.2/27.0
Sound power level Cooling dBA 51.0 54.0 58.0 54.0 58.0
Heating dBA 51.0 54.0 58.0 54.0 58.0
Sound pressure Cooling Low/Medium/High dBA 28.0/31.0/35.0 29.0/33.0/37.0 29.0/35.0/41.0 29.0/33.0/37.0 29.0/35.0/41.0
level Heating Low/Medium/High dBA 28.0/31.0/33.0 29.0/33.0/37.0 29.0/35.0/41.0 29.0/33.0/37.0 29.0/35.0/41.0
Control systems Infrared remote control BRC7FA532F / BRC7FB532F / BRC7FA532FB / BRC7FB532FB
Wired remote control BRC1H52W/S/K / BRC1E53A / BRC1E53B / BRC1E53C / BRC1D52
Power supply Phase/Frequency/Voltage Hz/V 1~/50/60/220-240/220
Outdoor unit ARXM / AZAS ARXM71R AZAS100MV AZAS125MV AZAS140MV AZAS100MY AZAS125MY AZAS140MY
Dimensions Unit HeightxWidthxDepth mm 734x954x401 990x940x320
Weight Unit kg 49.0 72 79 72 79
Sound power level Cooling dBA - 70 71 73 70 71 73
Heating dBA - 71 73 - 71 73
Sound pressure Cooling Nom. dBA 52.0 53 54 53 54
level Heating Nom. dBA 52.0 57
Operation range Cooling Ambient Min.~Max. °CDB -10~46
Heating Ambient Min.~Max. °CWB -15~24 -15~15.5
Refrigerant Type/GWP R-32/675
Charge kg/TCO2Eq 1.15/0.780 2.60/1.76 2.90/1.96 2.60/1.76 2.90/1.96
Piping connections Liquid/Gas OD mm 9.52/15.9
Piping OU - IU Max. m 30
length System Equivalent m 50
Chargeless m 30
Additional refrigerant charge kg/m 0.035 See installation manual
(for piping length exceeding 10m)

Level difference IU - OU Max. m 20.0 30.0


Power supply Phase/Frequency/Voltage Hz/V 1~/50 /220-240 3~/50 /380-415
Current - 50Hz Maximum fuse amps (MFA) A - 25 32 16
Contains fluorinated greenhouse gases
408
INTRODUCTION
FCAG-B + RXM-R(9)/A Split

Round flow cassette

RESIDENTIAL
INDOOR AIR
QUALITY
360° air discharge for optimum efficiency and comfort

› Combination with split outdoor units is ideal for small retail,


offices or residential applications

HEATING
› Optional automatic filter cleaning panel results in higher efficiency
& comfort and lower maintenance costs.
› Two optional intelligent sensors improve energy efficiency and
comfort FCAG-B
› Widest choice ever in decoration panels: designer panels in white
(RAL9010) and black (RAL9005) and standard panels in white

SPLIT
(RAL9010) with grey louvers or full white
› Bigger flaps and unique swing pattern improve equal air
distribution
› Individual flap control: flexibility to suit every room layout without
changing the location of the unit!

SKY AIR
› UV streamer kit, purifies the air of pollutants such as viruses, RXM-R BRC1H52W BRP069C82
bacteria, fine dust, odours, allergens, etc ensuring a healthy and
hygenic indoor environment
› Optional fresh air intake
› Branch duct discharge allows to optimize air distribution in

ROOFTOP
irregular shaped rooms or to supply air to small adjacent rooms
› Standard drain pump with 675mm lift increases flexibility and
installation speed White panel White auto cleaning panel Black panel Black design panel

More details and final information


can be found by scanning or
clicking the QR codes. FCAG-B RXM-R RXM-R9 RXM-A

VRV
Efficiency data FCAG + RXM 35B + 35R9 50B + 50A 60B + 60R
Cooling capacity Nom. kW 3.50 5.00 5.70
Heating capacity Nom. kW 4.20 6.00 7.00
Space cooling Energy efficiency class A++ A++

AIR PURIFICATION
VENTILATION &
Capacity Pdesign kW 3.50 5.00 5.70

COMMERCIAL
SEER 6.35 6.54 6.40
Annual energy consumption kWh/a 193 268 312
Space heating Energy efficiency class A++ A+
(Average climate) Capacity Pdesign kW 3.32 4.36 4.71
SCOP/A 4.90 4.30 4.20
Annual energy consumption kWh/a 948 1,418 1,569
Indoor unit FCAG 35B 50B 60B

INDUSTRY
MARINE
Dimensions Unit HeightxWidthxDepth mm 204x840x840
Weight Unit kg 18 19
Air filter Type Resin net
Decoration panel Model Standard panels: BYCQ140E - white with grey louvers / BYCQ140EW - full white / BYCQ140EB - black
Auto cleaning panels: BYCQ140EGF - white / BYCQ140EGFB - black
Designer panels: BYCQ140EP - white / BYCQ140EPB - black
Dimensions HeightxWidthxDepth mm Standard panels: 65x950x950 / Auto cleaning panels: 148x950x950 / Designer panels: 106x950x950

CHILLERS
Weight kg Standard panels: 5.5 / Auto cleaning panels: 10.3 / Designer panels: 6.5
Fan Air flow Cooling Low/Medium/High m³/min 8.8/10.6/12.9 9.4/11.8/14.6 9.6/12.2/14.9
rate Heating Low/Medium/High m³/min 9.4/11.6/14.1 9.4/11.8/14.6 9.6/12.2/14.9
Sound power level Cooling dBA 49.0 49.0 51.0
Heating dBA 49.0 49.0 51.0
Sound pressure Cooling Low/Medium/High dBA 27.0/29.0/31.0 28.0/31.0/33.0
level Heating Low/Medium/High dBA 27.0/29.0/31.0 28.0/31.0/33.0
FAN COIL

Control systems Infrared remote control BRC7FA532F / BRC7FB532F / BRC7FA532FB / BRC7FB532FB


UNITS

Wired remote control BRC1H52W/S/K / BRC1E53A / BRC1E53B / BRC1E53C / BRC1D52


Power supply Phase/Frequency/Voltage Hz/V 1~/50/60/220-240/220
NEW
Outdoor unit RXM 35R9 50A 60R
Dimensions Unit HeightxWidthxDepth mm 552x840x350 734x954x401
AIR HANDLING

Weight Unit kg 32 49.0


Sound pressure Cooling Nom. dBA 49.0 48.0
UNITS

level Heating Nom. dBA 49.0


Operation range Cooling Ambient Min.~Max. °CDB -10~46
Heating Ambient Min.~Max. °CWB -15~18
Refrigerant Type R-32
GWP 675.0
REFRIGERATION
COMMERCIAL &

Charge kg/TCO2Eq 0.76/0.52 1.15/0.780


TRANSPORT

Piping connections Liquid OD mm 6.35


Gas OD mm 9.50 12.7
Piping OU - IU Max. m 20 30
length System Chargeless m 10
Additional refrigerant charge kg/m 0.02 (for piping length exceeding 10m)
Level difference IU - OU Max. m 15 20.0
Power supply Phase/Frequency/Voltage Hz/V 1~/50 /220-240
CONTROL
SYSTEMS

Current - 50Hz Maximum fuse amps (MFA) A 13 16


Contains fluorinated greenhouse gases
409
Fully Flat Cassette
Design & Genius in one

Why choose fully flat cassette


› Unique design in the market that integrates
Benefits for the installer
fully flat into the ceiling
› Unique product in the market!
› Advanced technology and top efficiency combined › Most quiet unit (25dBA)
› The user-friendly remote control, available in several
› Most quiet cassette available on the market languages, enables the easy set-up of sensor option
and control of the individual flap position
› Meeting European design taste.

Benefits for the consultant


FFA-A9 / FXZQ-A › Unique product in the market!
› Blends seamlessly in any modern office
interior design
› Ideal product to improve BREEAM score/EPBD
in combination with Sky Air (FFA*) or VRV IV heat
pump units (FXZQ*).

Benefits for the end user


› Engineering excellence and unique design in one
› Most quiet unit (25dBA)
› Perfect working conditions: no more cold draughts
› Save up to 27% on your energy bill thanks
to the optional sensors
› Flexible usage of space and suits any room
configuration thanks to individual flap control
› User-friendly remote control, available
in several languages.

Choice between grey or white panel

410
INTRODUCTION
RESIDENTIAL
INDOOR AIR
QUALITY
HEATING
Unique design

› Designed by a European design office to fully › Fully integrated in the one ceiling tile, enabling
meet the European taste. lights, speakers and sprinklers to be installed in
› Fully flat into the ceiling, leaving only 8mm. adjoining ceiling tiles.

SPLIT
› Decoration panel available in 2 colours
(white and white-silver).

SKY AIR
ROOFTOP
Differentiating in technology

VRV
Optional presence sensor Optional floor sensor
› When the room is empty, it can adjust the set › Detects the temperature difference and
temperature or switch off the unit – saving re-directs the airflow to ensure even

AIR PURIFICATION
energy. temperature distribution.

VENTILATION &
COMMERCIAL
› When people are detected, the direction of
the airflow is adapted to avoid cold draughts
being directed towards occupants.

INDUSTRY
MARINE
CHILLERS

Top efficiency Other benefits


FAN COIL
UNITS

*
› Seasonal efficiency labels up to › Individual flap control: easily control one or more
› When the room is empty, the sensor option can flaps via the wired remote controller (BRC1E/
adjust the set temperature or switch off the unit BRC1H) when rearranging the room. When fully
– saving up to 27% energy. closing or blocking the flaps, the option “Sealing
AIR HANDLING

member of air discharge outlet” is needed.


UNITS

* for FFA25,35A9 in combination with RXM25,35 › Most silent cassette in the market (25dBA),
important for office applications.
REFRIGERATION
COMMERCIAL &
TRANSPORT

Marketing tools
› https://www.daikin.eu/en_us/product-group/fully-flat-cassette.html
› www.youtube.com/DaikinEurope
CONTROL
SYSTEMS

411
FFA-A9 + RZAG-A

Fully flat cassette


Unique design in the market that
integrates fully flat into the ceiling

› Combination with Sky Air Alpha-series ensures best in class


quality, highest efficiency and performance
› Fully flat integration in standard architectural ceiling tiles, leaving
only 8mm
› Remarkable blend of iconic design and engineering excellence FFA-A9
with an elegant finish in white or a combination of silver and
white
› Two optional intelligent sensors improve energy efficiency and
comfort
› Individual flap control: flexibility to suit every room layout without
changing the location of the unit!
› Optional fresh air intake
› Branch duct discharge allows to optimize air distribution in RZAG35-60A BRC1H52W BRP069C81
irregular shaped rooms or to supply air to small adjacent rooms
› Standard drain pump with 630mm lift increases flexibility and
installation speed

More details and final information


can be found by scanning or
clicking the QR codes. FFA-A9 RZAG-A
Efficiency data FFA + RZAG 35A9 + 35A 50A9 + 50A 60A9 + 60A
Cooling capacity Min./Nom./Max. kW 1.6/3.5/4.5 1.7/5.0/6.0 1.7/6.0/6.5
Heating capacity Min./Nom./Max. kW 1.40/4.00/5.00 1.50/5.80/6.00 1.60/7.00/7.50
Space cooling Energy efficiency class A++ A+
Capacity Pdesign kW 3.50 5.00 6.00
SEER 6.40 6.30 5.80
Annual energy consumption kWh/a 191 278 362
Space heating Energy efficiency class A A+
(Average climate) Capacity Pdesign kW 4.20 4.30 4.50
SCOP/A 3.80 4.01 4.04
Annual energy consumption kWh/a 1,546 1,501 1,558
Indoor unit FFA 35A9 50A9 60A9
Dimensions Unit HeightxWidthxDepth mm 260x575x575
Weight Unit kg 16.0 17.5
Air filter Type Resin net
Decoration panel Model BYFQ60C2W1W / BYFQ60C2W1S / BYFQ60B2W1 / BYFQ60B3W1
Colour White (N9.5)/SILVER/White (RAL9010)/WHITE (RAL9010)
Dimensions HeightxWidthxDepth mm 46x620x620 / 46x620x620 / 55x700x700 / 55x700x700
Weight kg 2.8/2.8/2.7/2.7
Fan Cooling Low/Medium/High m³/min
Air flow 6.5/8.5/10.0 8.6/10.9/12.7 9.5/12.5/14.5
rate Heating Low/Medium/High m³/min 6.5/8.5/10.0 8.6/10.9/12.7 9.5/12.5/14.5
Sound power level Cooling dBA 51.0 56.0 60.0
Sound pressure Cooling Low/Medium/High dBA 25.0/30.5/34.0 27.0/34.0/39.0 32.0/40.0/43.0
level Heating Low/Medium/High dBA 25.0/30.5/34.0 27.0/34.0/39.0 32.0/40.0/43.0
Control systems Infrared remote control BRC7EB530W (standard panel) / BRC7F530W (white panel) / BRC7F530S (grey panel)
Wired remote control BRC1H52W/S/K / BRC1E53A / BRC1E53B / BRC1E53C / BRC1D52
Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240
Outdoor unit RZAG 35A 50A 60A
Dimensions Unit HeightxWidthxDepth mm 734x870x373
Weight Unit kg 52
Sound power level Cooling dBA 62.0 63.0 64.0
Heating dBA 62.0 63.0 64.0
Sound pressure Cooling Nom. dBA 48.0 49.0 50.0
level Heating Nom. dBA 48.0 49.0 50.0
Operation range Cooling Ambient Min.~Max. °CDB -20~52
Heating Ambient Min.~Max. °CWB -20~24
Refrigerant Type/GWP R-32/675.0
Charge kg/TCO2Eq 1.55/1.05
Piping connections Liquid/Gas OD mm 6.35/9.52 6.35/12.7
Piping OU - IU Max. m 50
length System Chargeless m 30
Additional refrigerant charge kg/m 0.02 (for piping length exceeding 30m)
Level difference IU - OU Max. m 30.0
Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240
Contains fluorinated greenhouse gases

412
INTRODUCTION
FFA-A9 + RXM-R(9)/A Split

Fully flat cassette

RESIDENTIAL
INDOOR AIR
QUALITY
Unique design in the market that
integrates fully flat into the ceiling

› Combination with split outdoor units is ideal for small retail,

HEATING
offices and residential applications
› Fully flat integration in standard architectural ceiling tiles, leaving
only 8mm
› Remarkable blend of iconic design and engineering excellence with FFA-A9
an elegant finish in white or a combination of silver and white
› Unified indoor unit range for R-32 and R-410A

SPLIT
› Two optional intelligent sensors improve energy efficiency and
comfort
› Individual flap control: flexibility to suit every room layout without
changing the location of the unit!
› Optional fresh air intake

SKY AIR
› Branch duct discharge allows to optimize air distribution in RXM-R BRC1H52W BRP069C81
irregular shaped rooms or to supply air to small adjacent rooms
› Standard drain pump with 630mm lift increases flexibility and
installation speed

ROOFTOP
More details and final information
can be found by scanning or
clicking the QR codes. FFA-A9 RXM-R RXM-R9 RXM-A
Efficiency data FFA + RXM 25A9 + 25R9 35A9 + 35R9 50A9 + 50A 60A9 + 60R
Cooling capacity Nom. kW 2.50 3.40 5.00 5.70
Heating capacity Nom. kW 3.20 4.20 5.80 7.00
Power input Cooling Nom. kW 0.55 0.89 1.54 1.86

VRV
Heating Nom. kW 0.82 1.20 1.66 2.05
Space cooling Energy efficiency class A++ A+
Capacity Pdesign kW 2.50 3.40 5.00 5.70
SEER 6.17 6.38 5.98 5.76
Annual energy consumption kWh/a 142 186 293 346

AIR PURIFICATION
VENTILATION &
COMMERCIAL
Space heating Energy efficiency class A+ A A+
(Average climate) Capacity Pdesign kW 2.31 3.10 3.84 3.96
SCOP/A 4.24 4.10 3.90 4.04
Annual energy consumption kWh/a 762 1,058 1,378 1,373
Nominal efficiency EER 4.57 3.81 3.24 3.05
COP 3.90 3.50 3.49 3.41
Annual energy consumption kWh 273 446 772 931
Energy labeling Directive Cooling/Heating A/A A/B B/B

INDUSTRY
MARINE
Indoor unit FFA 25A9 35A9 50A9 60A9
Dimensions Unit HeightxWidthxDepth mm 260x575x575
Weight Unit kg 16.0 17.5
Air filter Type Resin net
Decoration panel Model BYFQ60C2W1W / BYFQ60C2W1S / BYFQ60B2W1 / BYFQ60B3W1
Colour White (N9.5)/SILVER/White (RAL9010)/WHITE (RAL9010)
Dimensions HeightxWidthxDepth mm 46x620x620 / 46x620x620 / 55x700x700 / 55x700x700

CHILLERS
Weight kg 2.8/2.8/2.7/2.7
Fan Air flow Cooling Low/Medium/High m³/min 6.5/8.0/9.0 6.5/8.5/10.0 8.6/10.9/12.7 9.5/12.5/14.5
rate Heating Low/Medium/High m³/min 6.5/8.0/9.0 6.5/8.5/10.0 8.6/10.9/12.7 9.5/12.5/14.5
Sound power level Cooling dBA 48.0 51.0 56.0 60.0
Sound pressure Cooling Low/Medium/High dBA 25.0/28.5/31.0 25.0/30.5/34.0 27.0/34.0/39.0 32.0/40.0/43.0
level Heating Low/Medium/High dBA 25.0/28.5/31.0 25.0/30.5/34.0 27.0/34.0/39.0 32.0/40.0/43.0
Control systems Infrared remote control BRC7EB530W (standard panel) / BRC7F530W (white panel) / BRC7F530S (grey panel)
FAN COIL

Wired remote control BRC1H52W/S/K / BRC1E53A / BRC1E53B / BRC1E53C / BRC1D52


UNITS

Power supply Phase/Frequency/Voltage Hz/V 1~/50 /220-240


NEW
Outdoor unit RXM 25R9 35R9 50A 60R
Dimensions Unit HeightxWidthxDepth mm 552x840x350 734x954x401
Weight Unit kg 32 49.0
AIR HANDLING

Sound pressure Cooling Nom. dBA 46.0 49.0 48.0


UNITS

level Heating Nom. dBA 47.0 49.0


Operation range Cooling Ambient Min.~Max. °CDB -10~46
Heating Ambient Min.~Max. °CWB -15~18
Refrigerant Type R-32
GWP 675 675.0
Charge kg/TCO2Eq 0.76/0.52 1.15/0.780
REFRIGERATION
COMMERCIAL &
TRANSPORT

Piping connections Liquid OD mm 6.35


Gas OD mm 9.52 12.7
Piping OU - IU Max. m 20 30
length System Chargeless m 10
Additional refrigerant charge kg/m 0.02 (for piping length exceeding 10m)
Level difference IU - OU Max. m 15 20.0
Power supply Phase/Frequency/Voltage Hz/V 1~/50 /220-240
Current - 50Hz Maximum fuse amps (MFA) A 13 16
CONTROL
SYSTEMS

Contains fluorinated greenhouse gases

413
Auto cleaning filter
for concealed ceiling units

The unique automatic cleaning filter achieves higher efficiency


and comfort with lower maintenance costs
airflow
direction

Reduce running costs


› Automatic filter cleaning ensures low maintenance costs
because the filter is always clean
UNIQUE
Patents
Efficiency profile change for duct indoor unit during operation pending
100% Up to 20%
Energy saved
Gradual loss of thanks to
efficiency due automatic filter
to dirty filter cleaning

0%
start 6 months 12 months

Minimal time required for filter cleaning


› The dust box can be emptied with a vacuum cleaner for fast
and easy cleaning
› No more dirty ceilings
How does it work?
1 Scheduled automatic filter cleaning
Improved indoor air quality
› Optimum airflow eliminates draft and insulates sound
2 Dust collects in a dust box that’s
Superb reliability integrated into the unit
› Prevents clogged filters for seamless operation

Unique technology 3 The dust can easily be removed


› Unique and innovative filter technology inspired with a vacuum cleaner
by the Daikin auto cleaning cassette

Combination table youtube.com/DaikinEurope


Split / Sky Air VRV
Specifications
FDXM-F9 FXDA-A/FXDQ-A3

25 35 50 60 15 20 25 32 40 50 63 BAE20A62 BAE20A82 BAE20A102

BAE20A62       Height (mm) 210


BAE20A82   Width (mm) 830 1,030 1,230
BAE20A102    Depth (mm) 188

414
INTRODUCTION
Multi zoning kit

RESIDENTIAL
INDOOR AIR
QUALITY
for concealed ceiling units

HEATING
Easy selecti­­on
via our NEW
The multi-zoning system is a room-by-room controller. It is fitted with motorised dampers, which immediately software!

SPLIT
adapt using Daikin ducted solutions. This system supports control of up to 8 zones via a centralised thermostat
located in the main room and individual thermostats for each of the zones.

Benefits How does it work?

SKY AIR
Increased comfort 20°C
› Increases comfort levels by allowing more 19°C
individual zone control
- Up to 8 individual zones can be served thanks
to separate modulating dampers Zoning box:
fully pre-assembled

ROOFTOP
- Individual thermostat for room-by-room or 21°C plenum with
zone-by-zone control dampers

Easy to install Individual zone thermostats


› Automatic air flow adjustment according to the
Bluezero - Airzone Main Airzone Zone Thermostat Airzone Zone Thermostat
demand Thermostat › Graphic interface with › Thermostat with buttons for
› Easy to install, integrates with the Daikin indoor

VRV
› Color graphic interface for low-energy e-ink screen for controlling the temperature
units and system controls controlling zones controlling zones
› Time saving as plenum comes fully pre-assembled
with dampers, and control boards

AIR PURIFICATION
› Reduces the amount of refrigerant required in the

VENTILATION &
COMMERCIAL
installation
AZCE6BLUEZEROCB (Wired) AZCE6THINKRB (Wireless) AZCE6LITECB (Wired)
AZCE6LITERB (Wireless)

Compatibility
FDXM-F9 FBA-A(9) ADEA-A FXDQ-A3 FXSQ-A

INDUSTRY
Ø

MARINE
Number of Dimensions
Reference 25 35 50 60 35 50 60 71 100 125 140 71 100 125 15 20 25 32 40 50 63 15 20 25 32 40 50 63 80 100 125 140
motorised dampers H x W x D (mm) (mm)

2
AZEZ6DAIST07XS2 • • • •
AZEZ6DAIST07S2
300 x 930 x 454
• • • •
3
AZEZ6DAIST07XS3 • • • •
AZEZ6DAIST07S3 • • • •
4
AZEZ6DAIST07S4
300 x 1,140 x 454
• • • •
AZEZ6DAIST07M4 • • • • •

CHILLERS
Standard plenum AZEZ6DAIST07M5 • • • • •
5 300 x 1,425 x 454 200
AZEZ6DAIST07L5 • • • • • • •
6
AZEZ6DAIST07M6
300 x 1,638 x 454
• • • • •
AZEZ6DAIST07L6 • • • • • • •
7
AZEZ6DAIST07L7 • • • • • • •
AZEZ6DAIST07XL7
515 x 1,425 x 454

AZEZ6DAIST07L8 • • • • • • •
FAN COIL

8

UNITS

AZEZ6DAIST07XL8

2
AZEZ6DAIBS07XS2 • • • •
AZEZ6DAIBS07S2 • • • •
AZEZ6DAIBS07XS3 250 x 930 x 454 • • • •
3 AZEZ6DAIBS07S3 • • • •
AZEZ6DAIBS07M3 • • • • •
AIR HANDLING

AZEZ6DAIBS07S4 • • • •
• • • • •
UNITS

Medium plenum 4 AZEZ6DAIBS07M4 250 x 1,140 x 454


AZEZ6DAIBS07L4 200 • • • • • • •
AZEZ6DAIBS07S5 • • • •
5
AZEZ6DAIBS07M5
250 x 1,425 x 454
• • • • •
AZEZ6DAIBS07L5 • • • • • • •
AZEZ6DAIBS07XL5 •
REFRIGERATION
COMMERCIAL &

• • • • •
TRANSPORT

AZEZ6DAIBS07M6
6 AZEZ6DAIBS07L6 250 x 1,638 x 454 • • • • • • •
AZEZ6DAIBS07XL6 •
Slim plenum 2 AZEZ6DAISL01S2
210 x 720 x 444
• • • • • •
3 AZEZ6DAISL01S3
200
• • • • • •
4 AZEZ6DAISL01M4 210 x 930 x 444 • •
5 AZEZ6DAISL01L5 210 x 1,140 x 444 • • •
(1) Reversible units can be blocked to heating only via AZX6MCS module
CONTROL
SYSTEMS

For more information on


options refer to page 932
415
FDXM-F9 + RZAG-A

Slim concealed ceiling unit


Compact concealed ceiling unit, with
a height of only 200mm

› Combination with Sky Air Alpha-series ensures best in class


quality, highest efficiency and performance
› Invisible unit as the unit is concealed in the ceiling: only the
suction and discharge grilles are visible
› Compact dimensions, can easily be mounted in a ceiling void of FDXM25-35F9
only 240mm
› Medium external static pressure up to 40Pa facilitates unit use
with flexible ducts of varying lengths
› Auto cleaning filter option ensures maximum efficiency, comfort
and reliability by regular filter cleaning
› Multi zoning kit allows multiple individually-controlled climate
zones to be served by one indoor unit
› Onecta app (optional): control your indoor from any with auto RZAG35-60A BRC1H52W BRP069C81
location with an app, via your local network or internet cleaning and
and keep an overview on your energy consumption multi zoning
option

More details and final information


can be found by scanning or
clicking the QR codes. FDXM-F9 RZAG-A
Efficiency data FDXM + RZAG 35F9 + 35A 50F9 + 50A 60F9 + 60A
Cooling capacity Min./Nom./Max. kW 1.6/3.5/4.5 1.7/5.0/6.0 1.7/6.0/6.5
Heating capacity Min./Nom./Max. kW 1.40/4.00/5.00 1.70/5.00/6.00 1.70/7.00/7.50
Space cooling Energy efficiency class A+
Capacity Pdesign kW 3.50 5.00 6.00
SEER 5.90 5.70
Annual energy consumption kWh/a 208 296 368
Space heating Energy efficiency class A
(Average climate) Capacity Pdesign kW 3.50 4.30 4.50
SCOP/A 3.90
Annual energy consumption kWh/a 1,255 1,544 1,616
Indoor unit FDXM 35F9 50F9 60F9
Dimensions Unit HeightxWidthxDepth mm 200x750x620 200x1,150x620
Weight Unit kg 21 28
Air filter Type Removable / washable
Fan Air flow Cooling Low/Medium/High m³/min 7.3/8.0/8.7 13.3/14.6/15.8 13.5/14.8/16.0
rate Heating Low/Medium/High m³/min 7.3/8.0/8.7 13.3/14.6/15.8 13.5/14.8/16.0
External static Nom. Pa 30 40
pressure
Sound power level Cooling dBA 53.0 55.0 56.0
Heating dBA 53.0 55.0 56.0
Sound pressure Cooling Low/High dBA 27.0/35.0 30.0/38.0
level Heating Low/High dBA 27.0/35.0 30.0/38.0
Control systems Infrared remote control BRC4C65
Wired remote control BRC1H52W/S/K, BRC1E53A/B/C, BRC1D52
Outdoor unit RZAG 35A 50A 60A
Dimensions Unit HeightxWidthxDepth mm 734x870x373
Weight Unit kg 52
Sound power level Cooling dBA 62.0 63.0 64.0
Heating dBA 62.0 63.0 64.0
Sound pressure Cooling Nom. dBA 48.0 49.0 50.0
level Heating Nom. dBA 48.0 49.0 50.0
Operation range Cooling Ambient Min.~Max. °CDB -20~52
Heating Ambient Min.~Max. °CWB -20~24
Refrigerant Type/GWP R-32/675.0
Charge kg/TCO2Eq 1.55/1.05
Piping connections Liquid/Gas OD mm 6.35/9.52 6.35/12.7
Piping OU - IU Max. m 50
length System Chargeless m 30
Additional refrigerant charge kg/m 0.02 (for piping length exceeding 30m)
Level difference IU - OU Max. m 30.0
Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240
Contains fluorinated greenhouse gases

416
INTRODUCTION
FDXM-F9 + RXM-R(9)/A Split

Slim concealed ceiling unit

RESIDENTIAL
INDOOR AIR
QUALITY
Compact concealed ceiling unit, with
a height of only 200mm

› Combination with split outdoor units is ideal for small retail,

HEATING
offices and residential applications
› Invisible unit as the unit is concealed in the ceiling: only the
suction and discharge grilles are visible
› Compact dimensions, can easily be mounted in a ceiling void of FDXM25-35F9
only 240mm
› Medium external static pressure up to 40Pa facilitates unit use

SPLIT
with flexible ducts of varying lengths
› Auto cleaning filter option ensures maximum efficiency, comfort
and reliability by regular filter cleaning
› Multi zoning kit allows multiple individually-controlled
climate zones to be served by one indoor unit

SKY AIR
› Onecta app (optional): control your indoor from with auto RXM-R BRC1H52W BRP069C81
any location with an app, via your local network or cleaning and
internet. multi zoning
option

ROOFTOP
More details and final information
can be found by scanning or

VRV
clicking the QR codes. FDXM-F9 RXM-R RXM-R9 RXM-A
Efficiency data FDXM + RXM 25F9 + 25R9 35F9 + 35R9 50F9 + 50A 60F9 + 60R
Cooling capacity Nom. kW 1.30/2.40/3.00 1.40/3.40/3.80 1.70/5.00/5.30 1.70/6.00/6.50

AIR PURIFICATION
Heating capacity Nom./Max. kW 1.30/3.20/4.50 1.40/4.00/5.00 1.70/5.80/6.00 1.70/7.00/7.10

VENTILATION &
COMMERCIAL
Space cooling Energy efficiency class A+ A A+ A
Capacity Pdesign kW 2.40 3.40 5.00 6.00
SEER 5.68 5.26 5.77 5.56
Annual energy consumption kWh/a 148 226 303 378
Space heating Energy efficiency class A+ A A
(Average climate) Capacity Pdesign kW 2.60 2.90 4.00 4.60
SCOP/A 4.24 3.88 3.93 3.80

INDUSTRY
MARINE
Annual energy consumption kWh/a 858 1,046 1,424 1,693
Indoor unit FDXM 25F9 35F9 50F9 60F9
Dimensions Unit HeightxWidthxDepth mm 200x750x620 200x1,150x620
Weight Unit kg 21 28
Air filter Type Removable/washable
Fan Air flow Cooling Low/Medium/High m³/min 7.3/8.0/8.7 13.3/14.6/15.8 13.5/14.8/16.0

CHILLERS
rate Heating Low/Medium/High m³/min 7.3/8.0/8.7 13.3/14.6/15.8 13.5/14.8/16.0
External static Nom. Pa 30 40
pressure
Sound power level Cooling dBA 53.0 55.0 56.0
Heating dBA 53.0 55.0 56.0
Sound pressure Cooling Low/High dBA 27.0/35.0 30.0/38.0
level Heating Low/High dBA 27.0/35.0 30.0/38.0
FAN COIL
UNITS

NEW
Outdoor unit RXM 25R9 35R9 50A 60R
Dimensions Unit HeightxWidthxDepth mm 552x840x350 734x954x401
Weight Unit kg 32 49.0
Sound pressure Cooling Nom. dBA 46.0 49.0 48.0
AIR HANDLING

level Heating Nom. dBA 47.0 49.0 49.0


Operation range Cooling Ambient Min.~Max. °CDB -10~46
UNITS

Heating Ambient Min.~Max. °CWB -15~18


Refrigerant Type R-32 R-32
GWP 675 675.0
Charge kg/TCO2Eq 0.76/0.52 1.15/0.780
Piping connections Liquid OD mm 6.35
REFRIGERATION
COMMERCIAL &
TRANSPORT

Gas OD mm 9.50 12.7


Piping OU - IU Max. m 20 30
length System Chargeless m 10 10
Additional refrigerant charge kg/m 0.02 (for piping length exceeding 10m) 0.02 (for piping length exceeding 10m)
Level difference IU - OU Max. m 15 20.0
Power supply Phase/Frequency/Voltage Hz/V 1~/50 /220-240 1~/50 /220-240
Current - 50Hz Maximum fuse amps (MFA) A 13 16
CONTROL
SYSTEMS

Contains fluorinated greenhouse gases

417
FBA-A(9) + RZAG-A / NV1 / NY1

Concealed ceiling unit


with medium ESP
Slimmest yet most powerful medium
outblow
static pressure unit on the market
rear
› Slimmest unit in class, only 245mm (300mm built-in height) and suction
bottom
therefore narrow ceiling voids are no longer a challenge suction
› Low operation sound level down to 25dBA FBA100-140A(9)
› Medium external static pressure up to 150Pa facilitates using
flexible ducts of varying lengths
› Possibility to change ESP via wired remote control allows
optimisation of the supply air volume
› Discretely concealed in the ceiling: only the suction and discharge
grilles are visible
› Multi zoning kit allows multiple individually-controlled climate
zones to be served by one indoor unit RZAG-NV1_NY1 BRC1H52W, BRP069A81 with
› Optional fresh air intake multi zoning
› Flexible installation: air suction direction can be altered from rear option
to bottom suction and choice between free use or connection to
optional suction grilles
› Standard built-in drain pump with 625mm lift increases flexibility More details and FBA-A(9) RZAG-A
and installation speed final information
can be found by
scanning or clicking
the QR codes. RZAG-NV1 RZAG-NY1
Efficiency data FBA + RZAG 35A9+35A 50A9+50A 60A9+60A 71A9+71NV1 100A+100NV1 125A+125NV1 140A+140NV1 71A9+71NY1 100A+100NY1 125A+125NY1 140A+140NY1
Cooling capacity Min./Nom./Max. kW 1.6/3.5/5.0 1.7/5.0/6.0 1.7/6.0/7.0 -/6.80/- -/9.50/- -/12.1/- -/13.4/- -/6.80/- -/9.50/- -/12.1/- -/13.4/-
Heating capacity Min./Nom./Max. kW 1.40/4.00/5.00 1.70/6.00/6.00 1.70/7.00/7.50 -/7.50/- -/10.8/- -/13.5/- -/15.5/- -/7.50/- -/10.8/- -/13.5/- -/15.5/-
Space cooling Energy efficiency class A++ - A++ -
Capacity Pdesign kW 3.50 5.00 6.00 6.80 9.50 12.1 13.4 6.80 9.50 12.1 13.4
SEER 6.12 6.30 6.15 6.50 6.47 6.56 6.42 6.50 6.47 6.56 6.42
ηs,c % - 259 254 - 259 254
Annual energy consumption kWh/a 200 278 341 366 514 1,107 1,252 366 514 1,107 1,252
Space heating Energy efficiency class A+ - A+ -
(Average climate) Capacity Pdesign kW 4.20 4.30 4.50 4.70 7.80 9.52 4.70 7.80 9.52
SCOP/A 4.10 4.20 4.36 4.37 4.34 4.20 4.36 4.37 4.34
ηs,h % - 172 171 - 172 171
Annual energy consumption kWh/a 1,434 1,469 1,537 1,566 2,505 3,050 3,070 1,566 2,505 3,050 3,070
Indoor unit FBA 35A9 50A9 60A9 71A9 100A 125A 140A 71A9 100A 125A 140A
Dimensions Unit HeightxWidthxDepth mm 245x700x800 245x1,000x800 245x1,400x800 245x1,000x800 245x1,400x800
Weight Unit kg 28.0 35.0 46.0 35.0 46.0
Air filter Type Resinnet
Fan Air flow Cooling Low/Medium/High m³/min 10.5/12.5/15.0 12.5/15.0/18.0 23.0/26.0/29.0 23.5/29.0/34.0 12.5/15.0/18.0 23.0/26.0/29.0 23.5/29.0/34.0
rate Heating Low/Medium/High m³/min 10.5/12.5/15.0 12.5/15.0/18.0 23.0/26.0/29.0 23.5/29.0/34.0 12.5/15.0/18.0 23.0/26.0/29.0 23.5/29.0/34.0
External static Nom./High Pa 30/150 40/150 50/150 30/150 40/150 50/150
pressure
Sound power level Cooling dBA 60.0 56.0 58.0 62.0 56.0 58.0 62.0
Sound pressure Cooling Low/High dBA 29.0/35.0 25.0/30.0 30.0/34.0 32.0/37.0 25.0/30.0 30.0/34.0 32.0/37.0
level Heating Low/High dBA 29.0/37.0 25.0/31.0 30.0/36.0 32.0/38.0 25.0/31.0 30.0/36.0 32.0/38.0
Control systems Infrared remote control BRC4C65 / BRC4C66
Wired remote control BRC1H52W/S/K / BRC1E53A / BRC1E53B / BRC1E53C / BRC1D52
Power supply Phase/Frequency/Voltage Hz/V 1~/50/60/220-240/220
Piping connections Drain VP20 (I.D. 20/O.D. 26)
Drain-up height mm 625
Outdoor unit RZAG 35A 50A 60A 71NV1 100NV1 125NV1 140NV1 71NY1 100NY1 125NY1 140NY1
Dimensions Unit HeightxWidthxDepth mm 734x870x373 870x1,100x460
Weight Unit kg 52 81 85 95 81 85 94
Sound power level Cooling dBA 62.0 63.0 64.0 64 66 69 70 64 66 69 70
Heating dBA 62.0 63.0 64.0 - 68 71 - 68 71
Sound pressure Cooling Nom. dBA 48.0 49.0 50.0 46 47 49 50 46 47 49 50
level Heating Nom. dBA 48.0 49.0 50.0 48 50 52 48 50 52
Operation range Cooling Ambient Min.~Max. °CDB -20 ~ 52 -20 ~52
Heating Ambient Min.~Max. °CWB -20 ~ 24 -20 ~18
Refrigerant Type/GWP R-32/675.0 R-32/675
Charge kg/TCO2Eq 1.55/1.05 3.20/2.16 3.70/2.50 3.20/2.16 3.70/2.50
Piping connections Liquid/Gas OD mm 6.35/9.52 6.35/12.7 9.52/15.9
Piping OU - IU Max. m 50 55 85 55 85
length System Equivalent m - 75 100 75 100
Chargeless m 30 40
Level difference IU - OU Max. m 30.0 30
Additional refrigerant charge kg/m 0.02 (for piping length exceeding 30m) See installation manual
Power supply Phase/Frequency/Voltage Hz/V 1~/50 /220-240 3~/50 /380-415
Current - 50Hz Maximum fuse amps (MFA) A - 20 32 16
Contains fluorinated greenhouse gases

418
INTRODUCTION
FBA-A(9) + RZASG-MV(1)/MY(1)

Concealed ceiling unit

RESIDENTIAL
INDOOR AIR
QUALITY
with medium ESP
Slimmest yet most powerful medium
outblow
static pressure unit on the market

HEATING
rear
› Combination with Sky Air Advance-series ensures good value for suction
bottom
money for all types of commercial applications suction
› Slimmest unit in class, only 245mm (300mm built-in height) and FBA100-140A(9)
therefore narrow ceiling voids are no longer a challenge
› Low operation sound level down to 25dBA

SPLIT
› Medium external static pressure up to 150Pa facilitates using
flexible ducts of varying lengths
› Possibility to change ESP via wired remote control allows
optimisation of the supply air volume

SKY AIR
RZASG100-140MV(1)/MY(1) BRC1H52W BRP069C81 with
Optimised supply air volume External static pressure (Pa)
multi zoning
Automatically selects the most appropriate fan curve
to achieve the units’ nominal air flow within ±10% Fan characteristic
Air flow (rated) More details and final information can be option
curves
found by scanning or clicking the QR codes.
Why? Air flow (actual)
After installation the real ducting will frequently

ROOFTOP
differ from the initially calculated air flow resistance
 the real air flow may be much lower or higher
than nominal, leading to a lack of capacity or
Air flow (with
FBA-A(9) RZASG-MV1 RZASG-MY1
uncomfortable air temperature. Automatic Airflow Duct resistance
automatic adjustment)
Adjustment function will adapt the unit’s fan speed curves
to any ducting automatically (10 or more fan curves
are ­available on every model), making installation
much faster ±10% Air flow (m3/min)

RZASG-MV RZASG-MY

VRV
Efficiency data FBA + RZASG 71A9 + 71MV1 100A + 100MV(1) 125A + 125MV(1) 140A + 140MV(1) 100A + 100MY(1) 125A + 125MY(1) 140A + 140MY(1)
Cooling capacity Nom. kW 6.80 9.50 12.1 13.4 9.50 12.1 13.4
Heating capacity Nom. kW 7.50 10.8 13.5 15.5 10.8 13.5 15.5
Space cooling Energy efficiency class A++ A+ - A+ -

AIR PURIFICATION
VENTILATION &
Capacity Pdesign kW 6.80 9.50 12.1 13.4 9.50 12.1 13.4

COMMERCIAL
SEER 6.19 5.83 5.49 5.81 5.83 5.49 5.81
ηs,c % - 217 229 - 217 229
Annual energy consumption kWh/a 385 570 1,322 1,384 570 1,322 1,384
Space heating Energy efficiency class A+ A - A -
(Average climate) Capacity Pdesign kW 4.50 6.00 7.80 6.00 7.80
SCOP/A 4.01 3.85 3.63 3.85 3.63 3.85
ηs,h % - 142 151 - 142 151

INDUSTRY
MARINE
Annual energy consumption kWh/a 1,571 2,182 2,314 2,836 2,182 2,314 2,836
Indoor unit FBA 71A9 100A 125A 140A 100A 125A 140A
Dimensions Unit HeightxWidthxDepth mm 245x1,000x800 245x1,400x800
Weight Unit kg 35.0 46.0
Air filter Type Resin net
Fan Air flow Cooling Low/Medium/High m³/min 12.5/15.0/18.0 20.0/24.5/29.0 23.5/29.0/34.0 20.0/24.5/29.0 23.5/29.0/34.0
rate Heating Low/Medium/High m³/min 12.5/15.0/18.0 20.0/24.5/29.0 23.5/29.0/34.0 20.0/24.5/29.0 23.5/29.0/34.0

CHILLERS
External static Nom. Pa 30 40 50 40 50
pressure
Sound power level Cooling dBA 56.0 58.0 62.0 58.0 62.0
Sound pressure Cooling Low/Medium/High dBA 25.0/28.0/30.0 30.0/32.0/34.0 32.0/35.0/37.0 30.0/32.0/34.0 32.0/35.0/37.0
level Heating Low/Medium/High dBA 25.0/28.0/31.0 30.0/33.0/36.0 32.0/35.0/38.0 30.0/33.0/36.0 32.0/35.0/38.0
Control systems Infrared remote control BRC4C65 / BRC4C66
Wired remote control BRC1H52W/S/K / BRC1E53A / BRC1E53B / BRC1E53C / BRC1D52
FAN COIL
UNITS

Power supply Phase/Frequency/Voltage Hz/V 1~/50/60/220-240/220


Outdoor unit RZASG 71MV1 100MV(1) 125MV(1) 140MV(1) 100MY(1) 125MY(1) 140MY(1)
Dimensions Unit HeightxWidthxDepth mm 770x900x320 990x940x320
Weight Unit kg 60 70 (MY1) / 72 (MY) 78 (MV1) / 79 (MV) 70 (MY1) / 72 (MY) 78 (MV1) / 79 (MV)
Sound power level Cooling dBA 65 70 71 73 70 71 73
AIR HANDLING

Heating dBA - 71 73 - 71 73
Sound pressure Cooling Nom. dBA 46 53 54 53 54
UNITS

level Heating Nom. dBA 47 57


Operation range Cooling Ambient Min.~Max. °CDB -15~46
Heating Ambient Min.~Max. °CWB -15~15.5
Refrigerant Type/GWP R-32/675
Charge kg/TCO2Eq 2.45/1.65 2.60/1.76 2.90/1.96 2.60/1.76 2.90/1.96
REFRIGERATION
COMMERCIAL &

Piping connections Liquid/Gas OD mm 9.52/15.9


TRANSPORT

Piping OU - IU Max. m 50
length System Equivalent m 70
Chargeless m 30
Additional refrigerant charge kg/m See installation manual
Level difference IU - OU Max. m 30.0
Power supply Phase/Frequency/Voltage Hz/V 1~/50 /220-240 3~/50 /380-415
Current - 50Hz Maximum fuse amps (MFA) A 20 25 32 16
CONTROL
SYSTEMS

Contains fluorinated greenhouse gases

419
FBA-A(9) + ARXM-R / AZAS-MV / MY

Concealed ceiling unit


with medium ESP
Slimmest yet most powerful medium
static pressure unit on the market
outblow

› Ideal solution for small businesses and shops


rear
› Slimmest unit in class, only 245mm (300mm built-in height) and suction
bottom
therefore narrow ceiling voids are no longer a challenge suction
› Low operation sound level down to 25dBA FBA100-140A(9)
› Medium external static pressure up to 150Pa facilitates using
flexible ducts of varying lengths
› Possibility to change ESP via wired remote control allows
optimisation of the supply air volume
› Discretely concealed in the ceiling: only the suction and discharge
grilles are visible
› Multi zoning kit allows multiple individually-controlled climate
zones to be served by one indoor unit AZAS71MV1_MY1 BRC1H52W BRP069C81
› Reduced energy consumption thanks to specially developed DC with
fan motor multi zoning
› Optional fresh air intake › Standard built-in drain pump with 625mm lift option
› Flexible installation: air suction direction can be altered from rear increases flexibility and installation speed
to bottom suction and choice between free use or connection to
optional suction grilles

More details and final information


can be found by scanning or
clicking the QR codes. FBA-A(9) ARXM-R AZAS-MV AZAS-MY
Efficiency data FBA + ARXM/AZAS 71A9 + ARXM71R 100A + AZAS100MV 125A + AZAS125MV 140A + AZAS140MV 100A + AZAS100MY 125A + AZAS125MY 140A + AZAS140MY
Cooling capacity Nom./Max. kW 6.80/6.98 9.50/- 12.1/- 13.4/- 9.50/- 12.1/- 13.4/-
Heating capacity Nom./Max. kW 7.50/7.66 10.8/- 13.5/- 15.5/- 10.8/- 13.5/- 15.5/-
Space cooling Energy efficiency class A - A -
Capacity Pdesign kW 6.80 9.50 12.1 13.0 9.50 12.1 13.0
SEER 5.57 5.7 5.2 5.7 5.7 5.2 5.7
ηs,c % - 205 225 - 205 225
Annual energy consumption kWh/a 427 633 1,497 1,418 633 1,497 1,418
Space heating Energy efficiency class A - A -
(Average climate) Capacity Pdesign kW 4.50 6.00 7.80 6.00 7.80
SCOP/A 3.81 3.55 3.85 3.81 3.55 3.85
ηs,h % - 139 151 - 139 151
Annual energy consumption kWh/a 1,652 2,205 2,366 2,836 2,205 2,366 2,836
Indoor unit FBA 71A9 100A 125A 140A 100A 125A 140A
Dimensions Unit HeightxWidthxDepth mm 245x1,000x800 245x1,400x800
Weight Unit kg 35.0 46.0
Air filter Type Resin net
Fan Air flow Cooling Low/Medium/High m³/min 12.5/15.0/18.0 20.0/24.5/29.0 23.5/29.0/34.0 20.0/24.5/29.0 23.5/29.0/34.0
rate Heating Low/Medium/High m³/min 12.5/15.0/18.0 20.0/24.5/29.0 23.5/29.0/34.0 20.0/24.5/29.0 23.5/29.0/34.0
External static Nom. Pa 30 40 50 40 50
pressure
Sound power level Cooling dBA 56.0 58.0 62.0 58.0 62.0
Sound pressure Cooling Low/Medium/High dBA 25.0/28.0/30.0 30.0/32.0/34.0 32.0/35.0/37.0 30.0/32.0/34.0 32.0/35.0/37.0
level Heating Low/Medium/High dBA 25.0/28.0/31.0 30.0/33.0/36.0 32.0/35.0/38.0 30.0/33.0/36.0 32.0/35.0/38.0
Control systems Infrared remote control BRC4C65 / BRC4C66
Wired remote control BRC1H52W/S/K / BRC1E53A / BRC1E53B / BRC1E53C / BRC1D52
Power supply Phase/Frequency/Voltage Hz/V 1~/50/60/220-240/220
Outdoor unit ARXM/AZAS ARXM71R AZAS100MV AZAS125MV AZAS140MV AZAS100MY AZAS125MY AZAS140MY
Dimensions Unit HeightxWidthxDepth mm 734x954x401 990x940x320
Weight Unit kg 49.0 72 79 72 79
Sound power level Cooling dBA - 70 71 73 70 71 73
Heating dBA - 71 73 - 71 73
Sound pressure Cooling Nom. dBA 52.0 53 54 53 54
level Heating Nom. dBA 52.0 57
Operation range Cooling Ambient Min.~Max. °CDB -10~46
Heating Ambient Min.~Max. °CWB -15~24 -15~15.5
Refrigerant Type/GWP R-32/675
Charge kg/TCO2Eq 1.15/0.780 2.60/1.76 2.90/1.96 2.60/1.76 2.90/1.96
Piping connections Liquid/Gas OD mm 9.52/15.9
Piping OU - IU Max. m - 30
length System Equivalent m - 50
Chargeless m 30
Additional refrigerant charge kg/m 0.035 See installation manual
(for piping length exceeding 10m)

Level difference IU - OU Max. m 20.0 30.0


Power supply Phase/Frequency/Voltage Hz/V 1~/50 /220-240 3~/50 /380-415
Current - 50Hz Maximum fuse amps (MFA) A - 25 32 16
Contains fluorinated greenhouse gases

420
INTRODUCTION
FBA-A(9) + RXM-R(9)/A Split

Concealed ceiling unit

RESIDENTIAL
INDOOR AIR
QUALITY
with medium ESP
Slimmest yet most powerful medium
outblow
static pressure unit on the market

HEATING
› Combination with split outdoor units is ideal for small retail, rear
suction
offices and residential applications bottom
suction
› Slimmest unit in class, only 245mm (300mm built-in height) and FBA35-50A(9)
therefore narrow ceiling voids are no longer a challenge
› Low operation sound level down to 25dBA

SPLIT
› Medium external static pressure up to 150Pa facilitates using
flexible ducts of varying lengths
› Possibility to change ESP via wired remote control allows
optimisation of the supply air volume

SKY AIR
RXM-R BRC1H52W BRP069C81 with
multi zoning
Optimised supply air volume External static pressure (Pa) option
Automatically selects the most appropriate fan curve More details and final information can be found
to achieve the units’ nominal air flow within ±10% Air flow (rated)
Fan characteristic
curves by scanning or clicking the QR codes.
Why?

ROOFTOP
Air flow (actual)
After installation the real ducting will frequently
differ from the initially calculated air flow resistance
 the real air flow may be much lower or higher
than nominal, leading to a lack of capacity or FBA-A(9) RXM-R
uncomfortable air temperature. Automatic Airflow Air flow (with
Duct resistance
automatic adjustment)
Adjustment function will adapt the unit’s fan speed curves
to any ducting automatically (10 or more fan curves
are ­available on every model), making installation

VRV
much faster ±10% Air flow (m3/min)
RXM-R9 RXM-A
Efficiency data FBA + RXM 35A9 + 35R9 50A9 + 50A 60A9 + 60R
Cooling capacity Nom. kW 3.40 5.00 5.70
Heating capacity Nom. kW 4.00 5.50 7.00

AIR PURIFICATION
VENTILATION &
COMMERCIAL
Space cooling Energy efficiency class A++ A+
Capacity Pdesign kW 3.40 5.00 5.70
SEER 6.23 6.27 5.91
Annual energy consumption kWh/a 191 279 336
Space heating Energy efficiency class A+
(Average climate) Capacity Pdesign kW 2.90 4.40 4.60
SCOP/A 4.07 4.06 4.01
Annual energy consumption kWh/a 996 1,517 1,607

INDUSTRY
MARINE
Indoor unit FBA 35A9 50A9 60A9
Dimensions Unit HeightxWidthxDepth mm 245x700x800 245x1,000x800
Weight Unit kg 28.0 35.0
Air filter Type Resin net
Fan Air flow Cooling Low/Medium/High m³/min 10.5/12.5/15.0 12.5/15.0/18.0
rate Heating Low/Medium/High m³/min 10.5/12.5/15.0 12.5/15.0/18.0

CHILLERS
External Nom. Pa 30
static
pressure
Sound power level Cooling dBA 60.0 56.0
Sound pressure Cooling Low/Medium/High dBA 29.0/32.0/35.0 25.0/28.0/30.0
level Heating Low/Medium/High dBA 29.0/34.0/37.0 25.0/28.0/31.0
Control systems Infrared remote control BRC4C65 / BRC4C66
Wired remote control BRC1H52W/S/K / BRC1E53A / BRC1E53B / BRC1E53C / BRC1D52
FAN COIL
UNITS

Power supply Phase/Frequency/Voltage Hz/V 1~/50/60/220-240/220


NEW
Outdoor unit RXM 35R9 50A 60R
Dimensions Unit HeightxWidthxDepth mm 552x840x350 734x954x401
Weight Unit kg 32 49.0
AIR HANDLING

Sound pressure Cooling Nom. dBA 49.0 48.0


level Heating Nom. dBA 49.0
UNITS

Operation range Cooling Ambient Min.~Max. °CDB -10~46


Heating Ambient Min.~Max. °CWB -15~18
Refrigerant Type R-32
GWP 675.0
Charge kg/TCO2Eq 0.76/0.52 1.15/0.780
REFRIGERATION
COMMERCIAL &

Piping connections Liquid OD mm 6.35


TRANSPORT

Gas OD mm 9.52 12.7


Piping OU - IU Max. m 20 30
length System Chargeless m 10
Additional refrigerant charge kg/m 0.02 (for piping length exceeding 10m)
Level difference IU - OU Max. m 15 20.0
Power supply Phase/Frequency/Voltage Hz/V 1~/50 /220-240
Current - 50Hz Maximum fuse amps (MFA) A 13 16
CONTROL
SYSTEMS

Contains fluorinated greenhouse gases

421
FDA-A + RZAG-NV1 / NY1 / RZASG-MV(1)/MY(1)

Concealed ceiling unit


with high ESP
ESP up to 200 Pa, ideal for large sized spaces
outblow

› High external static pressure up to 200Pa facilitates extensive duct


rear
and grille network suction
bottom
› Possibility to change ESP via wired remote control allows suction
optimisation of the supply air volume FDA125A
› Discretely concealed in the ceiling: only the suction and discharge
grilles are visible
› Built-in drain pump (625mm) increases the flexibility and
installation speed (standard for FDA125, optional for FDA200-250)
› Standard supplied suction filter simplifies installation

RZASG100-140MV(1)/MY(1) BRC1H52W, BRP069A81

FDA-A RZAG-NV1 RZAG-NY1

More details and final information can be


RZASG-MV1 RZASG-MY1 RZASG-MV RZASG-MY found by scanning or clicking the QR codes.
Sky Air Alpha-series Sky Air Advance-series
Efficiency data FDA125A+RZAG125NV1 FDA125A+RZAG125NY1 FDA125A+RZASG125MV(1) FDA125A+RZASG125MY(1)
Cooling capacity Nom. kW 12.1
Heating capacity Nom. kW 13.5
Space cooling Capacity Pdesign kW 12.1
SEER 6.59 5.03
ηs,c % 261 198
Annual energy consumption kWh/a 1,102 1,444
Space heating Capacity Pdesign kW 9.52 6.00
(Average climate) SCOP/A 4.35 3.58
ηs,h % 171 140
Annual energy consumption kWh/a 3,064 2,346
Indoor unit FDA 125A 125A 125A 125A
Dimensions Unit HeightxWidthxDepth mm 300x1,400x700
Weight Unit kg 45
Required ceiling void > mm 350
Air filter Type Resin net
Decoration panel Model BYBS125DJW1
Colour White (10Y9/0.5)
Dimensions HeightxWidthxDepth mm 55x1,500x500
Weight kg 6.5
Fan Air flow Cooling Low/High m³/min 28.0/39.0
rate Heating Low/High m³/min 28.0/39.0
External static Nom./High Pa 50/200
pressure
Sound power level Cooling dBA 66
Sound pressure Cooling Low/High dBA 33/40
level Heating Low/High dBA 33/40
Control systems Infrared remote control BRC4C65/BRC4C66
Wired remote control BRC1H52W/S/K/BRC1E53A/BRC1E53B/BRC1E53C/BRC1D52
Power supply Phase/Frequency/Voltage Hz/V 1~/50/60/220-240/220
Piping connections Drain VP25 (I.D. 25/O.D. 32)
Outdoor unit RZAG125NV1 RZAG125NY1 RZASG125MV(1) RZASG125MY(1)
Dimensions Unit HeightxWidthxDepth mm 870x1,100x460 990x940x320
Weight Unit kg 95 94 70 (MV1/MY1) / 72 (MV/MY)
Sound power level Cooling dBA 69 71
Heating dBA 68 -
Sound pressure Cooling Nom. dBA 49 54
level Heating Nom. dBA 52 58
Operation range Cooling Ambient Min.~Max. °CDB -20~52 -15~46
Heating Ambient Min.~Max. °CWB -20~18 -15~15.5
Refrigerant Type/GWP R-32/675 R-32/675
Charge kg/TCO2Eq 3.70/2.50 2.60/1.76
Piping connections Liquid/Gas OD mm 9.52/15.9 9.52/15.9
Piping OU - IU Max. m 85 50
length System Equivalent m 100 70
Chargeless m 40 30
Level difference IU - OU Max. m 30 30.0
Additional refrigerant charge kg/m See installation manual See installation manual
Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240 3~/50/380-415 1~/50/220-240 3~/50/380-415
Current - 50Hz Maximum fuse amps (MFA) A 32 16 32 16
Contains fluorinated greenhouse gases

422
INTRODUCTION
FDA-A + RZA-D

Concealed ceiling unit

RESIDENTIAL
INDOOR AIR
QUALITY
with high ESP
ESP up to 250 Pa, ideal for large sized spaces

HEATING
› High external static pressure up to 250Pa facilitates extensive duct low
outb
and grille network
rear
› Possibility to change ESP via wired remote control allows suction
optimisation of the supply air volume FDA200-250A
› Discretely concealed in the ceiling: only the suction and discharge
grilles are visible

SPLIT
› Optional drain pump
› Standard supplied suction filter simplifies installation
› Up to 26.4kW in heating mode

SKY AIR
RZA-D BRC1H52W BRP069C81

ROOFTOP
More details and final information
can be found by scanning or

VRV
clicking the QR codes. FDA-A RZA-D
Efficiency data FDA + RZA 200A + 200D 250A + 250D
Cooling capacity Min./Nom./Max. kW -/19.0/- -/22.0/-

AIR PURIFICATION
Heating capacity Min./Nom./Max. kW -/22.4/- -/24.0/-

VENTILATION &
COMMERCIAL
Space cooling Capacity Pdesign kW 19.0 22.0
SEER 6.26 5.38
ηs,c % 247 212
Annual energy consumption kWh/a 1,821 2,455
Space heating Capacity Pdesign kW 11.2 12.1
(Average climate) SCOP/A 3.59 3.55
ηs,h % 141 139

INDUSTRY
MARINE
Annual energy consumption kWh/a 4,368 4,765
Indoor unit FDA 200A 250A
Dimensions Unit HeightxWidthxDepth mm 470x1,490x1,100
Weight Unit kg 104 115
Air filter Type Resinnet
Fan Cooling Low/Medium/High m³/min
Air flow 36.0/50/64.0 43.0/56/69.0

CHILLERS
rate Heating Low/Medium/High m³/min 36.0/50.0/64.0 43.0/56.0/69.0
External Nom./High Pa 62/250
static
pressure
Sound power level Cooling dBA 69.0 71.0
Sound pressure Cooling Low / Medium / High dBA 36.0/39.0/43.0 37.0/40.0/44.0
level Heating Low / Medium / High dBA 36.0/39.0/43.0 37.0/40.0/44.0
FAN COIL

Control systems Wired remote control BRC1H52W/S/K / BRC1E53A / BRC1E53B / BRC1E53C / BRC1D52
UNITS

Piping connections Drain BSP1


Outdoor unit RZA 200D 250D
Dimensions Unit HeightxWidthxDepth mm 870x1,100x460
Weight Unit kg 117
AIR HANDLING

Sound power level Cooling dBA 73 76


Heating dBA 76 79
UNITS

Sound pressure Cooling Nom. dBA 53 57


level Heating Nom. dBA 60 63
Operation range Cooling Ambient Min.~Max. °CDB -20~46
Heating Ambient Min.~Max. °CWB -20~15
Refrigerant Type/GWP R-32/675
REFRIGERATION
COMMERCIAL &
TRANSPORT

Charge kg/TCO2Eq 5/3.38


Piping connections Liquid/Gas OD mm 9.52/22.2
Piping OU - IU Max. m 100
length System Chargeless m 30
Additional refrigerant charge kg/m See installation manual
Power supply Phase/Frequency/Voltage Hz/V 3~/50 /380-415
Current - 50Hz Maximum fuse amps (MFA) A 20
CONTROL
SYSTEMS

Contains fluorinated greenhouse gases

423
ADEA-A + ARXM-R / AZAS-MV

Concealed ceiling unit


Ideal for residential applications with false ceilings

› Combination with split outdoor units is ideal for small retail,


offices or residential applications outblow
› Slimmest unit in class, only 245mm (300mm built-in height) and
therefore narrow ceiling voids are no longer a challenge rear
suction
› Low operation sound level down to 25dBA bottom
suction
› Medium external static pressure up to 150Pa facilitates using ADEA35-60A
flexible ducts of varying lengths
› Possibility to change ESP via wired remote control allows
optimisation of the supply air volume
› Discretely concealed in the ceiling: only the suction and discharge
grilles are visible
› Multi zoning kit allows multiple individually-controlled climate
zones to be served by one indoor unit with
AZAS100-140MV1_MY1 BRC1E53A/B/C BRP069C81
multi zoning
Optimised supply air volume External static pressure (Pa) option
Automatically selects the most appropriate fan curve
to achieve the units’ nominal air flow within ±10% Air flow (rated)
Fan characteristic
curves

Why? Air flow (actual)


After installation the real ducting will frequently
differ from the initially calculated air flow resistance More details and final information can be
 the real air flow may be much lower or higher
than nominal, leading to a lack of capacity or found by scanning or clicking the QR codes.
uncomfortable air temperature. Automatic Airflow Air flow (with
Duct resistance
automatic adjustment)
Adjustment function will adapt the unit’s fan speed curves
to any ducting automatically (10 or more fan curves
are ­available on every model), making installation
much faster ±10% Air flow (m3/min)
ADEA-A ARXM-R AZAS-MV
Efficiency data ADEA + ARXM / AZAS 71A + ARXM71R 100A + AZAS100MV 125A + AZAS125MV
Cooling capacity Nom. kW 6.80/6.98 9.50 12.10
Heating capacity Nom. kW 7.50/7.66 10.80 13.50
Space cooling Energy efficiency class A A -
Capacity Pdesign kW 6.80 9.50 12.10
SEER 5.35 5.13 4.73
ηs,c % 445 - 186
Annual energy consumption kWh/a A 648 1,534
Space heating Energy efficiency class 6.00 A -
(Average climate) Capacity Pdesign kW 3.80 6.00
SCOP/A 2,209 3.81 3.50
ηs,h % - 137
Annual energy consumption kWh/a 2,206 2,399
Indoor unit ADEA 71A 100A 125A
Dimensions Unit HeightxWidthxDepth mm 245x1,000x800 245x1,400x800
Weight Unit kg 35.0 46.0
Air filter Type Resin net
Fan Air flow Cooling Low/Medium/High m³/min 12.5/15.0/18.0 23.0/26.0/29.0 23.5/29.0/34.0
rate Heating Low/Medium/High m³/min 12.5/15.0/18.0 23.0/26.0/29.0 23.5/29.0/34.0
External static Nom./High Pa 30/150 40/150 50/150
pressure
Sound power level Cooling dBA 56 58 62
Sound pressure Cooling Low/Medium/High dBA 25/28/30 30/32/34 32/35/37
level Heating Low/Medium/High dBA 25/28/31 30/33/36 32/35/38
Control systems Infrared remote control BRC4C65 / BRC4C66
Wired remote control BRC1E53A / BRC1E53B / BRC1E53C / BRC1D52
Power supply Phase/Frequency/Voltage Hz/V 1~/50 /220-240/220
Outdoor unit ARXM / AZAS ARXM71R AZAS100MV AZAS125MV
Dimensions Unit HeightxWidthxDepth mm 734x954x401 990x940x320
Weight Unit kg 49.0 72
Sound power level Cooling dBA - 70 71
Heating dBA - - 71
Sound pressure Cooling Nom. dBA 52.0 53
level Heating Nom. dBA 52.0 57
Operation range Cooling Ambient Min.~Max. °CDB -10 ~46
Heating Ambient Min.~Max. °CWB -15~24 -15 ~15.5
Refrigerant Type/GWP R-32/675
Charge kg/TCO2Eq 1.15/0.780 2.60/1.76
Piping connections Liquid/Gas OD mm 9.52/15.9
Piping OU - IU Max. m 30
length System Equivalent m - 50
Chargeless m - 30
Additional refrigerant charge kg/m 0.035 (for piping length exceeding 10m) See installation manual
Level difference IU - OU Max. m 20.0 30.0
Power supply Phase/Frequency/Voltage Hz/V 1~/50 /220-240
Current - 50Hz Maximum fuse amps (MFA) A - 25 32
Contains fluorinated greenhouse gases

424
INTRODUCTION
FAA-B + RZAG-NV1 / NY1

Wall mounted unit

RESIDENTIAL
INDOOR AIR
QUALITY
For rooms with no false ceilings nor free floor space

› Combination with Sky Air Alpha-series ensures best in class


quality, highest efficiency and performance

HEATING
› Flat, stylish front panel blends easily within any interior décor and
is easier to clean
› Can easily be installed in both new and refurbishment projects
› The air is comfortably spread up- and downwards thanks to FAA71B
5 different discharge angles that can be programmed via the
remote control

SPLIT
› Maintenance operations can be performed easily from the front of
the unit
› Flexible to install as the largest casing only weighs 17kg and piping
connection can be done at the bottom, left or right of the unit

SKY AIR
RZAG-NV1_NY1 BRC1H52W, BRP069C81

ROOFTOP
VRV
More details and final information
can be found by scanning or
clicking the QR codes. FAA-B RZAG-NV1 RZAG-NY1

AIR PURIFICATION
VENTILATION &
COMMERCIAL
Efficiency data FAA + RZAG 71B + 71NV1 100B + 100NV1 71B + 71NY1 100B + 100NY1
Cooling capacity Nom. kW 6.80 9.50 6.80 9.50
Heating capacity Nom. kW 7.50 10.80 7.50 10.80
Space cooling Energy efficiency class A++
Capacity Pdesign kW 6.80 9.50 6.80 9.50
SEER 6.58 6.42 6.58 6.42
Annual energy consumption kWh/a 362 518 362 518

INDUSTRY
Space heating Energy efficiency class A+

MARINE
(Average climate) Capacity Pdesign kW 4.70 7.80 4.70 7.80
SCOP/A 4.20 4.01 4.20 4.01
Annual energy consumption kWh/a 1,567 2,725 1,567 2,725
Indoor unit FAA 71B 100B 71B 100B
Dimensions Unit HeightxWidthxDepth mm 290x1,050x269 340x1,200x262 290x1,050x269 340x1,200x262
Weight Unit kg 14.0 18 14.0 18

CHILLERS
Fan Cooling Low/Medium/High m³/min
Air flow 12.1/13.4/16.2 18.7/21.1/23.0 12.1/13.4/16.2 18.7/21.1/23.0
rateHeating Low/Medium/High m³/min 12.7/14.2/16.9 18.7/20.9/23.0 12.7/14.2/16.9 18.7/20.9/23.0
Sound power level Cooling dBA 61.0 65.0 61.0 65.0
Heating dBA 61.0 65.0 61.0 65.0
Sound pressure Cooling Low/Medium/High dBA 40.0/42.0/45.0 41.0/45.0/49.0 40.0/42.0/45.0 41.0/45.0/49.0
level Heating Low/Medium/High dBA 40.0/42.0/45.0 41.0/45.0/49.0 40.0/42.0/45.0 41.0/45.0/49.0
FAN COIL

Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240


UNITS

Outdoor unit RZAG 71NV1 100NV1 71NY1 100NY1


Dimensions Unit HeightxWidthxDepth mm 870x1,100x460
Weight Unit kg 81 85 81 85
Sound power level Cooling dBA 64 66 64 66
AIR HANDLING

Sound pressure Cooling Nom. dBA 46 47 46 47


level Heating Nom. dBA 48 50 48 50
UNITS

Operation range Cooling Ambient Min.~Max. °CDB -20 ~52


Heating Ambient Min.~Max. °CWB -20 ~18
Refrigerant Type/GWP R-32/675
Charge kg/TCO2Eq 3.20/2.16
Piping connections Liquid/Gas OD mm 9.52/15.9
REFRIGERATION
COMMERCIAL &
TRANSPORT

Piping OU - IU Max. m 55 85 55 85
length System Equivalent m 75 100 75 100
Chargeless m 40
Additional refrigerant charge kg/m See installation manual
Level difference IU - OU Max. m 30
Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240 3~/50/380-415
Current - 50Hz Maximum fuse amps (MFA) A 20 32 16
CONTROL
SYSTEMS

Contains fluorinated greenhouse gases

425
FAA-B + RZASG-MV(1)/MY(1)

Wall mounted unit


For rooms with no false ceilings nor free floor space

› Combination with Sky Air Advance-series ensures good value for


money for all types of commercial applications
› Flat, stylish front panel blends easily within any interior décor and
is easier to clean
› Can easily be installed in both new and refurbishment projects
› The air is comfortably spread up- and downwards thanks to FAA71B
5 different discharge angles that can be programmed via the
remote control
› Maintenance operations can be performed easily from the front of
the unit
› Flexible to install as the largest casing only weighs 17kg and piping
connection can be done at the bottom, left or right of the unit

RZASG100-140MV(1)/MY(1) BRC1H52W, BRP069C81

More details and


final information
can be found by
scanning or clicking
the QR codes. FAA-B RZASG-MV1 RZASG-MY1 RZASG-MV RZASG-MY
Efficiency data FAA + RZASG 71B + 71MV1 100B + 100MV(1) 100B + 100MY(1)
Cooling capacity Nom. kW 6.80 9.50
Heating capacity Nom. kW 7.50 10.8
Space cooling Energy efficiency class A++ A+
Capacity Pdesign kW 6.80 9.50
SEER 6.41 5.83
ηs,c % -
Annual energy consumption kWh/a 371 570
Space heating Energy efficiency class A
(Average climate) Capacity Pdesign kW 4.50 6.00
SCOP/A 3.90 3.85
ηs,h % -
Annual energy consumption kWh/a 1,615 2,182
Indoor unit FAA 71B 100B 100B
Dimensions Unit HeightxWidthxDepth mm 290x1,050x269 340x1,200x262
Weight Unit kg 14.0 18
Fan Air flow Cooling Low/Medium/High m³/min 12.1/13.4/16.2 18.7/21.1/23.0
rate Heating Low/Medium/High m³/min 12.7/14.2/16.9 18.7/20.9/23.0
Sound power level Cooling dBA 61.0 65.0
Heating dBA 61.0 65.0
Sound pressure Cooling Low/Medium/High dBA 40.0/42.0/45.0 41.0/45.0/49.0
level Heating Low/Medium/High dBA 40.0/42.0/45.0 41.0/45.0/49.0
Power supply Phase/Frequency/Voltage Hz/V 1~/50 /220-240
Outdoor unit RZASG 71MV1 100MV(1) 100MY(1)
Dimensions Unit HeightxWidthxDepth mm 770x900x320 990x940x320
Weight Unit kg 60 70 (MV1/MY1) / 72 (MV/MY)
Sound power level Cooling dBA 65 70
Sound pressure Cooling Nom. dBA 46 53
level Heating Nom. dBA 47 57
Operation range Cooling Ambient Min.~Max. °CDB -15~46
Heating Ambient Min.~Max. °CWB -15~15.5
Refrigerant Type/GWP R-32/675
Charge kg/TCO2Eq 2.45/1.65 2.60/1.76
Piping connections Liquid/ OD mm 9.52/15.9
Gas
Piping OU - IU Max. m 50
length System Equivalent m 70
Chargeless m 30
Additional refrigerant charge kg/m See installation manual
Level IU - OU Max. m 30.0
difference
Power supply Phase/Frequency/Voltage Hz/V 1~/50 /220-240 3~/50 /380-415
Current - 50Hz Maximum fuse amps (MFA) A 20 25 16
Contains fluorinated greenhouse gases

426
INTRODUCTION
FAA-B + ARXM-R / AZAS-MV / MY

Wall mounted unit

RESIDENTIAL
INDOOR AIR
QUALITY
For rooms with no false ceilings nor free floor space

› Ideal solution for small businesses and shops


› Flat, stylish front panel blends easily within any interior décor and

HEATING
is easier to clean
› Can easily be installed in both new and refurbishment projects
› The air is comfortably spread up- and downwards thanks to
5 different discharge angles that can be programmed via the FAA71B
remote control
› Maintenance operations can be performed easily from the front of

SPLIT
the unit
› Flexible to install as the largest casing only weighs 17kg and piping
connection can be done at the bottom, left or right of the unit

SKY AIR
AZAS100-140MV1_MY1 BRC1H52W, BRP069C81

ROOFTOP
More details and final information

VRV
can be found by scanning or
clicking the QR codes. FAA-B ARXM-R AZAS-MV AZAS-MY
Efficiency data FAA + ARXM/AZAS 71B + ARXM71R 100B + AZAS100MV 100B + AZAS100MY

AIR PURIFICATION
Cooling capacity Nom./Max. kW 6.80/6.95 9.50 /-

VENTILATION &
COMMERCIAL
Heating capacity Nom./Max. kW 7.50/7.59 10.8 /-
Space cooling Energy efficiency class A+ A
Capacity Pdesign kW 6.80 9.50
SEER 5.77 5.25
Annual energy consumption kWh/a 412 633
Space heating Energy efficiency class A
(Average climate) Capacity Pdesign kW 4.50 6.00

INDUSTRY
MARINE
SCOP/A 3.81 3.81
Annual energy consumption kWh/a 1,652 2,205
Indoor unit FAA 71B 100B 100B
Dimensions Unit HeightxWidthxDepth mm 290x1,050x269 340x1,200x262
Weight Unit kg 14.0 18
Fan Cooling Low/Medium/High m³/min
Air flow 12.1/13.4/16.2 18.7/21.1/23.0

CHILLERS
rateHeating Low/Medium/High m³/min 12.7/14.2/16.9 18.7/20.9/23.0
Sound power level Cooling dBA 61.0 65.0
Heating dBA 61.0 65.0
Sound pressure Cooling Low/Medium/High dBA 40.0/42.0/45.0 41.0/45.0/49.0
level Heating Low/Medium/High dBA 40.0/42.0/45.0 41.0/45.0/49.0
Power supply Phase/Frequency/Voltage Hz/V 1~/50 /220-240 1~/50 /220-240
FAN COIL

Outdoor unit ARXM/AZAS ARXM71R AZAS100MV AZAS100MY


UNITS

Dimensions Unit HeightxWidthxDepth mm 734x954x401 990x940x320


Weight Unit kg 49.0 72
Sound power level Cooling dBA - 70
Sound pressure Cooling Nom. dBA 52.0 53
level Heating Nom. dBA 52.0 57
AIR HANDLING

Operation range Cooling Ambient Min.~Max. °CDB -10~46


UNITS

Heating Ambient Min.~Max. °CWB -15~24 -15~15.5


Refrigerant Type/GWP R-32/675
Charge kg/TCO2Eq 1.15/0.780 2.60/1.76
Piping connections Liquid/ OD mm 9.52/15.9
Gas
REFRIGERATION
COMMERCIAL &

Piping OU - IU Max. m 30
TRANSPORT

length System Equivalent m - 50


Chargeless m - 30
Additional refrigerant charge kg/m 0.035 (for piping length exceeding 10m) See installation manual
Level IU - OU Max. m 20.0 30.0
difference
Power supply Phase/Frequency/Voltage Hz/V 1~/50 /220-240 3~/50 /380-415
Current - 50Hz Maximum fuse amps (MFA) A - 25 16
CONTROL
SYSTEMS

Contains fluorinated greenhouse gases

427
FTXM-R + RZAG-A

Wall mounted unit


Attractive, wall mounted design with
perfect indoor air quality

› Combination with Sky Air Alpha-series ensures best in class


quality, highest efficiency and performance
› Seasonal efficiency values up to A+++ in cooling and heating
› Practically inaudible: the unit runs so quietly, you will almost
forget it is there FTXM-R
› Cleaner air thanks to Daikin’s Flash Streamer technology: you can
breathe deep with no worries about impure air
› 2-area motion detection sensor: air flow is sent to a zone other
than where the person is located at that moment; if no people are
detected, the unit will automatically switch over to the energy-
efficient setting. (larger capacity area)
› Onecta app: control your indoor from any location with an app,
via your local network or internet RZAG35-60A ARC466A33
› Sleek, unobtrusive air conditioning unit that matches European
sensibilities regarding interior design
› 3-D air flow combines vertical and horizontal auto swing to
circulate a stream of warm or cool air right to the corners of even
large spaces

More details and final information


can be found by scanning or
clicking the QR codes. FTXM-R RZAG-A
Efficiency data FTXM + RZAG 35R + 35A 50R + 50A 60R + 60A
Cooling capacity Min./Nom./Max. kW 1.6/3.5/5.0 1.7/5.0/6.0 1.7/6.0/6.8
Heating capacity Min./Nom./Max. kW 1.40/4.00/5.30 1.50/6.00/6.50 1.60/7.00/7.50
Space cooling Energy efficiency class A++
Capacity Pdesign kW 3.50 5.00 6.00
SEER 7.70 7.41 6.90
Annual energy consumption kWh/a 159 236 304
Space heating Energy efficiency class A++ A+
(Average climate) Capacity Pdesign kW 2.60 4.50 4.60
SCOP/A 4.60 4.35
Annual energy consumption kWh/a 790 1,369 1,480
Indoor unit FTXM 35R 50R 60R
Dimensions Unit HeightxWidthxDepth mm 295x778x272 299x998x292
Weight Unit kg 10.0 14.5
Air filter Type Removable/washable
Fan Air flow Silent operation/ m³/min
Cooling 4.2/6.0/7.8/11.3 8.3/11.4/14/15.8 9.1/11.8/14/16.7
rate Low/Medium/High
Heating Silent operation/ m³/min 4.9/6.5/8.5/9.8 10.5/12.0/14.2/15.8 11.1/12.4/15.2/16.5
Low/Medium/High
Sound power level Cooling dBA 58 58.0 60.0
Heating dBA 54 58.0 59.0
Sound pressure Cooling Silent operation/Low/High dBA 19/29/45 27.0/36.0/44.0 30.0/37.0/46.0
level Heating Silent operation/Low/High dBA 20/28/39 31.0/34.0/43.0 33.0/36.0/45.0
Control systems Infrared remote control ARC466A67
Wired remote control BRC073A1
Outdoor unit RZAG 35A 50A 60A
Dimensions Unit HeightxWidthxDepth mm 734x870x373
Weight Unit kg 52
Sound power level Cooling dBA 62.0 63.0 64.0
Heating dBA 62.0 63.0 64.0
Sound pressure Cooling Nom. dBA 48.0 49.0 50.0
level Heating Nom. dBA 48.0 49.0 50.0
Operation range Cooling Ambient Min.~Max. °CDB -20~52
Heating Ambient Min.~Max. °CWB -20~24
Refrigerant Type/GWP R-32/675.0
Charge kg/TCO2Eq 1.55/1.05
Piping connections OD mm 6.35/9.52 6.35/12.7
Piping OU - IU Max. m 50
length System Chargeless m 30
Additional refrigerant charge kg/m 0.02 (for piping length exceeding 30m)
Level difference IU - OU Max. m 30.0
Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240
Contains fluorinated greenhouse gases

428
INTRODUCTION
FHA-A(9) + RZAG-A / NV1 / NY1

Ceiling suspended unit

RESIDENTIAL
INDOOR AIR
QUALITY
For wide rooms with no false ceilings nor free floor space

› Combining with Sky Air Advance-series ensures good value for


money for all types of commercial applications

HEATING
› Ideal for comfortable air flow in wide rooms thanks to Coanda
effect: up to 100° discharge angle

FHA60-71A9

SPLIT
› Even rooms with ceilings up to 3.8m can be heated up or cooled
down very easily without capacity loss
› Can easily be installed in both new and refurbishment projects
› Can easily be mounted in corners and narrow spaces, as it only
needs 30mm lateral service space

SKY AIR
RZAG35-60A BRC1H52W, BRP069A81

Air outlet
Air inlet
30 or more 30 or more
(Service space) (Service space) Obstruction

› Reduced energy consumption thanks to specially developed DC


More details and FHA-A(9) RZAG-A

ROOFTOP
fan motor
› 5 different fan speeds available for maximum comfort final information
can be found by
scanning or clicking
the QR codes. RZAG-NV1 RZAG-NY1
Efficiency data FHA + RZAG 35A9+35A 50A9+50A 60A9+60A 71A9+71NV1 100A+100NV1 125A+125NV1 140A+140NV1 71A9+71NY1 100A+100NY1 125A+125NY1 140A+140NY1
Cooling capacity Min./Nom./Max. kW 1.70/3.50/4.50 1.70/5.00/6.00 1.90/6.00/6.80 -/6.80/- -/9.50/- -/12.1/- -/13.4/- -/6.80/- -/9.50/- -/12.1/- -/13.4/-

VRV
Heating capacity Min./Nom./Max. kW 1.40/4.00/5.50 1.70/5.80/6.50 1.70/7.00/7.50 -/7.50/- -/10.8/- -/13.5/- -/15.5/- -/7.50/- -/10.8/- -/13.5/- -/15.5/-
Space cooling Energy efficiency class A++ - A++ -
Capacity Pdesign kW 3.50 5.00 6.00 6.80 9.50 12.1 13.4 6.80 9.50 12.1 13.4
SEER 6.40 6.80 6.60 7.11 6.42 7.14 6.42 7.11 6.42 7.14 6.42

AIR PURIFICATION
ηs,c % - 283 254 - 283 254

VENTILATION &
COMMERCIAL
Annual energy consumption kWh/a 191 257 318 335 518 1,017 1,253 335 518 1,017 1,253
Space heating Energy efficiency class A+ A++ - A+ A++ -
(Average climate) Capacity Pdesign kW 3.10 4.00 4.60 4.70 7.80 9.52 4.70 7.80 9.52
SCOP/A 4.10 4.30 4.20 4.32 4.61 4.20 4.30 4.32 4.61 4.20 4.30
ηs,h % - 165 169 - 165 169
Annual energy consumption kWh/a 1,058 1,302 1,633 1,523 2,369 3,174 3,100 1,523 2,369 3,174 3,100
Indoor unit FHA 35A9 50A9 60A9 71A9 100A 125A 140A 71A9 100A 125A 140A

INDUSTRY
MARINE
Dimensions Unit HeightxWidthxDepth mm 235x960x690 235x1,270x690 235x1,590x690 235x1,270x690 235x1,590x690
Weight Unit kg 26 27 32 34 41 34 41
Air filter Type Resinnet
Fan Air flow Cooling Low/Medium/High m³/min 10.0/11.5/14.0 10.0/12.0/15.0 11.5/15.0/19.5 14.0/17.0/20.5 20.0/24.0/28.0 23.0/27.0/31.0 24.0/29.0/34.0 14.0/17.0/20.5 20.0/24.0/28.0 23.0/27.0/31.0 24.0/29.0/34.0
rate Heating Low/Medium/High m³/min 10.0/11.5/14.0 10.0/12.0/15.0 11.5/15.0/19.5 14.0/17.0/20.5 20.0/24.0/28.0 23.0/27.0/31.0 24.0/29.0/34.0 14.0/17.0/20.5 20.0/24.0/28.0 23.0/27.0/31.0 24.0/29.0/34.0
Sound power level Cooling dBA 53.0 54.0 55.0 60.0 62.0 64.0 55.0 60.0 62.0 64.0
Heating dBA 53.0 54.0 55.0 60.0 62.0 64.0 55.0 60.0 62.0 64.0

CHILLERS
Sound pressure Cooling Low/High dBA 31.0/36.0 32.0/37.0 33.0/37.0 34.0/38.0 34.0/42.0 37.0/44.0 38.0/46.0 34.0/38.0 34.0/42.0 37.0/44.0 38.0/46.0
level Heating Nom./High dBA 34.0/36.0 35.0/37.0 36.0/38.0 38.0/42.0 41.0/44.0 42.0/46.0 36.0/38.0 38.0/42.0 41.0/44.0 42.0/46.0
Control systems Infrared remote control BRC7GA53-9 / BRC7GA56
Wired remote control BRC1D528 / BRC1H51(9)W/S/K7 / BRC1H52W/S/K / BRC1H81W7 / BRC1H81S7 / BRC1E53A/B/C7 / BRC1H82W/S/K
Power supply Phase/Frequency/Voltage Hz/V 1~/50/60/220-240/220
Piping connections Drain VP20
FAN COIL
UNITS

Outdoor unit RZAG 35A 50A 60A 71NV1 100NV1 125NV1 140NV1 71NY1 100NY1 125NY1 140NY1
Dimensions Unit HeightxWidthxDepth mm 734x870x373 870x1,100x460
Weight Unit kg 52 81 85 95 81 85 94
Sound power level Cooling dBA 62.0 63.0 64.0 64 66 69 70 64 66 69 70
Heating dBA 62.0 63.0 64.0 - 68 71 - 68 71
Sound pressure Cooling Nom. dBA 48.0 49.0 50.0 46 47 49 50 46 47 49 50
AIR HANDLING

level Heating Nom. dBA 48.0 49.0 50.0 48 50 52 48 50 52


UNITS

Operation range Cooling Ambient Min.~Max. °CDB -20 ~ 52 -20 ~52


Heating Ambient Min.~Max. °CWB -20 ~ 24 -20 ~18
Refrigerant Type/GWP R-32/675.0 R-32/675
Charge kg/TCO2Eq 1.55/1.05 3.20/2.16 3.70/2.50 3.20/2.16 3.70/2.50
Piping connections Liquid/Gas OD mm 6.35/9.50 6.35/12.7 10/15.9
REFRIGERATION
COMMERCIAL &

Piping OU - IU Max. m 50 55 85 55 85
TRANSPORT

length System Equivalent m - 75 100 75 100


Chargeless m 30 40
Level difference IU - OU Max. m 30.0 30
Additional refrigerant charge kg/m 0.02 (for piping length See installation manual
exceeding 30m)
Power supply Phase/Frequency/Voltage Hz/V 1~/50 /220-240 3~/50 /380-415
Current - 50Hz Maximum fuse amps (MFA) A - 20 32 16
CONTROL
SYSTEMS

Contains fluorinated greenhouse gases

429
FHA-A(9) + RZASG-MV(1)/MY(1)

Ceiling suspended unit


For wide rooms with no false ceilings nor free floor space

› Combination with Sky Air Advance-series ensures good value for


money for all types of commercial applications
› Ideal for comfortable air flow in wide rooms thanks to Coanda
effect: up to 100° discharge angle
› Even rooms with ceilings up to 3.8m can be heated up or cooled
down very easily without capacity loss FHA60-71A9
› Can easily be installed in both new and refurbishment projects
› Can easily be mounted in corners and narrow spaces, as it only
needs 30mm lateral service space
› 5 different fan speeds available for maximum comfort
› Stylish unit blends easily with any interior. The flaps close entirely
when the unit is not operating and there are no air intake grilles
visible
RZASG100-140MV(1)/MY(1) BRC1H52W, BRP069A81

More details and


final information
can be found by
scanning or clicking
the QR codes. FHA-A(9) RZASG-MV1 RZASG-MY1 RZASG-MV RZASG-MY
Efficiency data FHA + RZASG 71A9 + 71MV1 100A + 100MV(1) 125A + 125MV(1) 140A + 140MV(1) 100A + 100MY(1) 125A + 125MY(1) 140A + 140MY(1)
Cooling capacity Nom. kW 6.80 9.50 12.1 13.4 9.50 12.1 13.4
Heating capacity Nom. kW 7.50 10.8 13.5 15.5 10.8 13.5 15.5
Space cooling Energy efficiency class A+ - A+ -
Capacity Pdesign kW 6.80 9.50 12.1 13.4 9.50 12.1 13.4
SEER 5.95 5.83 5.88 5.83 5.88
ηs,c % - 230 232 - 230 232
Annual energy consumption kWh/a 400 570 1,246 1,368 570 1,246 1,368
Space heating Energy efficiency class A - A -
(Average climate) Capacity Pdesign kW 4.50 6.00 7.80 6.00 7.80
SCOP/A 3.90 3.91 3.83 3.81 3.91 3.83 3.81
ηs,h % - 150 149 - 150 149
Annual energy consumption kWh/a 1,616 2,148 2,193 2,866 2,148 2,193 2,866
Indoor unit FHA 71A9 100A 125A
140A 100A 125A 140A
Dimensions Unit HeightxWidthxDepth mm 235x1,270x690 235x1,590x690
Weight Unit kg 34 41
Air filter Type Resin net
Fan Cooling Low/Medium/High m³/min 14.0/17.0/20.5 20.0/24.0/28.0 23.0/27.0/31.0 24.0/29.0/34.0 20.0/24.0/28.0 23.0/27.0/31.0 24.0/29.0/34.0
Air flow
rate Heating Low/Medium/High m³/min 14.0/17.0/20.5 20.0/24.0/28.0 23.0/27.0/31.0 24.0/29.0/34.0 20.0/24.0/28.0 23.0/27.0/31.0 24.0/29.0/34.0
Sound power level Cooling dBA 55.0 60.0 62.0 64.0 60.0 62.0 64.0
Heating dBA 55.0 60.0 62.0 64.0 60.0 62.0 64.0
Sound pressure Cooling Low/High dBA 34.0/38.0 34.0/42.0 37.0/44.0 38.0/46.0 34.0/42.0 37.0/44.0 38.0/46.0
level Heating Nom./High dBA 36.0/38.0 38.0/42.0 41.0/44.0 42.0/46.0 38.0/42.0 41.0/44.0 42.0/46.0
Control systems Infrared remote control BRC7GA53-9 / BRC7GA56
Wired remote control BRC1H52W/S/K; BRC1E53A; BRC1E53B; BRC1E53C; BRC1D52
Power supply Phase/Frequency/Voltage Hz/V 1~/50/60/220-240/220
Piping connections Drain VP20
Outdoor unit RZASG 71MV1 100MV(1) 125MV(1) 140MV(1) 100MY(1) 125MY(1) 140MY(1)
Dimensions Unit HeightxWidthxDepth mm 770x900x320 990x940x320
Weight Unit kg 60 70 (MY1) / 72 (MY) 78 (MV1) / 79 (MV) 70 (MY1) / 72 (MY) 78 (MV1) / 79 (MV)
Sound power level Cooling dBA 65 70 71 73 70 71 73
Heating dBA - 71 73 - 71 73
Sound pressure Cooling Nom. dBA 46 53 54 53 54
level Heating Nom. dBA 47 57
Operation range Cooling Ambient Min.~Max. °CDB -15~46
Heating Ambient Min.~Max. °CWB -15~15.5
Refrigerant Type/GWP R-32/675
Charge kg/TCO2Eq 2.45/1.65 2.60/1.76 2.90/1.96 2.60/1.76 2.90/1.96
Piping connections Liquid/ OD mm 9.52/15.9
Gas
Piping OU - IU Max. m 50
length System Equivalent m 70
Chargeless m 30
Level difference IU - OU Max. m 30.0
Additional refrigerant charge kg/m See installation manual
Power supply Phase/Frequency/Voltage Hz/V 1~/50 /220-240 3~/50 /380-415
Current - 50Hz Maximum fuse amps (MFA) A 20 25 32 16
Contains fluorinated greenhouse gases

430
INTRODUCTION
NEW FHA-A(9) + AZAS-MV/MY

Ceiling suspended unit

RESIDENTIAL
INDOOR AIR
QUALITY
For wide rooms with no false ceilings nor free floor space

› Ideal solution for small businesses and shops


› Ideal for comfortable air flow in wide rooms thanks to Coanda

HEATING
effect: up to 100° discharge angle
› Even rooms with ceilings up to 3.8m can be heated up or cooled
down very easily without capacity loss
› Can easily be installed in both new and refurbishment projects FHA60-71A9
› Can easily be mounted in corners and narrow spaces, as it only
needs 30mm lateral service space

SPLIT
› 5 different fan speeds available for maximum comfort
› Stylish unit blends easily with any interior. The flaps close entirely
when the unit is not operating and there are no air intake grilles
visible

SKY AIR
AZAS-MV/MY BRC1H52W, BRP069A81

ROOFTOP
More details and final information
can be found by scanning or
clicking the QR codes. FHA-A(9) AZAS-MV AZAS-MY
Efficiency data FHA + AZAS 100A + 100MV 125A + 125MV 140A + 140MV 100A + 100MY 125A + 125MY 140A + 140MY
Cooling capacity Nom. kW 9.50 12.1 13.4 9.50 12.1 13.4

VRV
Heating capacity Nom. kW 10.8 13.5 15.5 10.8 13.5 15.5
Space cooling Energy efficiency class A - A -
Capacity Pdesign kW 9.50 12.1 13.4 9.50 12.1 13.4
SEER 5.6
ηs,c % - 221 - 221

AIR PURIFICATION
VENTILATION &
COMMERCIAL
Annual energy consumption kWh/a 594 1,297 1,436 594 1,297 1,436
Space heating Energy efficiency class A - A -
(Average climate) Capacity Pdesign kW 6.00 7.80 6.00 7.80
SCOP/A 3.87 3.75 3.81 3.87 3.75 3.81
ηs,h % - 147 149 - 147 149
Annual energy consumption kWh/a 2,171 2,240 2,866 2,171 2,240 2,866
Indoor unit FHA 100A 125A 140A 100A 125A 140A

INDUSTRY
MARINE
Dimensions Unit HeightxWidthxDepth mm 235x1,590x690
Weight Unit kg 41
Air filter Type Resin net
Fan Air flow Low/Medium/High m³/min
Cooling 20.0/24.0/28.0 23.0/27.0/31.0 24.0/29.0/34.0 20.0/24.0/28.0 23.0/27.0/31.0 24.0/29.0/34.0
rate Low/Medium/High m³/min
Heating 20.0/24.0/28.0 23.0/27.0/31.0 24.0/29.0/34.0 20.0/24.0/28.0 23.0/27.0/31.0 24.0/29.0/34.0
Sound power level Cooling dBA 60.0 62.0 64.0 60.0 62.0 64.0
Heating dBA 60.0 62.0 64.0 60.0 62.0 64.0

CHILLERS
Sound pressure Cooling Low/High dBA 34.0/42.0 37.0/44.0 38.0/46.0 34.0/42.0 37.0/44.0 38.0/46.0
level Heating Nom./High dBA 38.0/42.0 41.0/44.0 42.0/46.0 38.0/42.0 41.0/44.0 42.0/46.0
Control systems Infrared remote control BRC7GA53-9 / BRC7GA56
Wired remote control RC1H52W/S/K; BRC1E53A; BRC1E53B; BRC1E53C; BRC1D52
Power supply Phase/Frequency/Voltage Hz/V 1~/50/60/220-240/220
Piping connections Drain VP20
FAN COIL
UNITS

Outdoor Unit AZAS100MV AZAS125MV AZAS140MV AZAS100MY AZAS125MY AZAS140MY


Dimensions Unit HeightxWidthxDepth mm 990x940x320
Weight Unit kg 72 79 72 79
Sound power level Cooling dBA 70 71 72 70 71 72
Heating dBA 70 71 72 70 71 72
AIR HANDLING

Sound pressure Cooling Nom. dBA 53 54 55 53 54 55


level Heating Nom. dBA 57 58 59 57 58 59
UNITS

Operation range Cooling Ambient Min.~Max. °CDB -10~46


Heating Ambient Min.~Max. °CWB -15~15.5
Refrigerant Type/GWP R-32/675
Charge kg/TCO2Eq 2.60/1.76 2.90/1.96 2.60/1.76 2.90/1.96
Piping connections Liquid/Gas OD mm 9.52/15.9
REFRIGERATION
COMMERCIAL &
TRANSPORT

Piping OU - IU Max. m 30
length System Equivalent m 50
Chargeless m 30
Additional refrigerant charge kg/m See installation manual
Level difference IU - OU Max. m 30.0
Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240 3~/50/380-415
Current - 50Hz Maximum fuse amps (MFA) A 25 32 16
CONTROL
SYSTEMS

Contains fluorinated greenhouse gases

431
FHA-A(9) + RXM-R(9)/A Split

Ceiling suspended unit


For wide rooms with no false ceilings nor free floor space

› Combination with split outdoor units is ideal for small retail,


offices and residential applications
› Ideal for comfortable air flow in wide rooms thanks to Coanda
effect: up to 100° discharge angle
› Even rooms with ceilings up to 3.8m can be heated up or cooled
down very easily without capacity loss FHA100-140A9
› Can easily be installed in both new and refurbishment projects
› Can easily be mounted in corners and narrow spaces, as it only
needs 30mm lateral service space
› 5 different fan speeds available for maximum comfort
› Stylish unit blends easily with any interior. The flaps close entirely
when the unit is not operating and there are no air intake grilles
visible
RXM-R9 BRC1H52W BRP069C81

More details and final information


can be found by scanning or
clicking the QR codes. FHA-A(9) RXM-R RXM-R9 RXM-A
Efficiency data FHA + RXM 35A9 + 35R9 50A9 + 50A 60A9 + 60R
Cooling capacity Nom. kW 3.40 5.00 5.70
Heating capacity Nom. kW 4.00 6.00 7.20
Space cooling Energy efficiency class A++ A+
Capacity Pdesign kW 3.40 5.00 5.70
SEER 6.24 5.92 6.08
Annual energy consumption kWh/a 191 295 328
Space heating Energy efficiency class A+ A
(Average climate) Capacity Pdesign kW 3.10 4.35 4.71
SCOP/A 4.43 3.86 3.87
Annual energy consumption kWh/a 979 1,577 1,704
Indoor unit FHA 35A9 50A9 60A9
Dimensions Unit HeightxWidthxDepth mm 235x960x690 235x960x690 235x1,270x690
Weight Unit kg 26 27 32
Air filter Type Resin net Resin net
Fan Air flow Low/Medium/High m³/min
Cooling 10.0/11.5/14.0 10.0/12.0/15.0 11.5/15.0/19.5
rate Low/Medium/High m³/min
Heating 10.0/11.5/14.0 10.0/12.0/15.0 11.5/15.0/19.5
Sound power level Cooling dBA 53.0 54.0
Heating dBA 53.0 54.0
Sound pressure Cooling Low/Medium/High dBA 31.0/34.0/36.0 32.0/35.0/37.0 33.0/35.0/37.0
level Heating Medium/Nom./High dBA 31.0/34.0/36.0 32.0/35.0/37.0 33.0/35.0/37.0
Control systems Infrared remote control BRC7GA53-9 / BRC7GA56
Wired remote control BRC1H52W/S/K / BRC1E53A/B/C / BRC1D52
Power supply Phase/Frequency/Voltage Hz/V 1~/50/60/220-240/220
NEW
Outdoor unit RXM 35R9 50A 60R
Dimensions Unit HeightxWidthxDepth mm 552x840x350 734x954x401
Weight Unit kg 32 49.0
Sound pressure Cooling Nom. dBA 49.0 48.0
level Heating Nom. dBA 49.0
Operation range Cooling Ambient Min.~Max. °CDB -10 ~ 46
Heating Ambient Min.~Max. °CWB -15 ~ 18
Refrigerant Type R-32
GWP 675.0
Charge kg/TCO2Eq 0.76/0.52 1.15/0.780
Piping connections Liquid OD mm 6.35
Gas OD mm 9.52 12.7
Piping OU - IU Max. m 20 30
length System Chargeless m 10
Additional refrigerant charge kg/m 0.02 (for piping length exceeding 10m)
Level IU - OU Max. m 15 20.0
difference
Power supply Phase/Frequency/Voltage Hz/V 1~/50 /220-240
Current - 50Hz Maximum fuse amps (MFA) A 13 16
Contains fluorinated greenhouse gases

432
INTRODUCTION
FUA-A + RZAG-NV1 / NY1

4-way blow ceiling

RESIDENTIAL
INDOOR AIR
QUALITY
suspended unit
Unique Daikin unit for high rooms with no
false ceilings nor free floor space

HEATING
› Combining with Sky Air Advance-series ensures good value for
money for all types of commercial applications
› Even rooms with ceilings up to 3.5m can be heated up or cooled FUA-A
down very easily without capacity loss
› Can easily be installed in both new and refurbishment projects

SPLIT
› Unified indoor unit range for R-32 and R-410A
› Individual flap control: flexibility to suit every room layout without
changing the location of the unit!

SKY AIR
RZAG-NV1_NY1 BRC1H52W, BRP069A81

› 5 different discharge angles between 0 and 60° can be › Stylish modern casing finished in pure white (RAL9010) and iron
programmed via the remote control grey (RAL7011) blends easily with any interior
› Optimum comfort guaranteed with automatic air flow

ROOFTOP
0° to 60°
adjustment to the required load
› Standard drain pump with 720mm lift increases flexibility and
installation speed
More details and final information can be
found by scanning or clicking the QR codes.

VRV
FUA-A RZAG-NV1 RZAG-NY1
Efficiency data FUA + RZAG 71A + 71NV1 100A + 100NV1 125A + 125NV1 71A + 71NY1 100A + 100NY1 125A + 125NY1

AIR PURIFICATION
VENTILATION &
Cooling capacity Nom. kW 6.80 9.50 12.1 6.80 9.50 12.1

COMMERCIAL
Heating capacity Nom. kW 7.50 10.8 13.5 7.50 10.8 13.5
Space cooling Energy efficiency class A++ - A++ -
Capacity Pdesign kW 6.80 9.50 12.1 6.80 9.50 12.1
SEER 7.02 6.42 6.39 7.02 6.42 6.39
ηs,c % - 253 - 253
Annual energy consumption kWh/a 339 518 1,136 339 518 1,136
Space heating Energy efficiency class A+ - A+ -

INDUSTRY
(Average climate) Capacity Pdesign kW 4.70 7.80 9.52 4.70 7.80 9.52

MARINE
SCOP/A 4.20 4.50 4.26 4.20 4.50 4.26
ηs,h % - 167 - 167
Annual energy consumption kWh/a 1,567 2,427 3,129 1,567 2,427 3,129
Indoor unit FUA 71A 100A 125A 71A 100A 125A
Dimensions Unit HeightxWidthxDepth mm 198x950x950
Weight Unit kg 25.0 26.0 25.0 26.0

CHILLERS
Air filter Type Resinnet
Fan Air flow Cooling Low/Medium/High m³/min 16.0/19.5/23.0 20.0/25.5/31.0 20.5/26.5/32.5 16.0/19.5/23.0 20.0/25.5/31.0 20.5/26.5/32.5
rate Heating Low/Medium/High m³/min 16.0/19.5/23.0 20.0/25.5/31.0 20.5/26.5/32.5 16.0/19.5/23.0 20.0/25.5/31.0 20.5/26.5/32.5
Sound power level Cooling dBA 59 64 65 59 64 65
Sound pressure Cooling Low/High dBA 35/41 39/46 40/47 35/41 39/46 40/47
level Heating Low/High dBA 35/41 39/46 40/47 35/41 39/46 40/47
Control systems Wired remote control BRC1H52W/S/K / BRC1E53A/B/C / BRC1D52
FAN COIL
UNITS

Piping connections Drain VP25 (OD Ø32.0)


Outdoor unit RZAG 71NV1 100NV1 125NV1 71NY1 100NY1 125NY1
Dimensions Unit HeightxWidthxDepth mm 870x1,100x460
Weight Unit kg 81 85 95 81 85 94
Sound power level Cooling dBA 64 66 69 64 66 69
AIR HANDLING

Heating dBA - 68 - 68
Sound pressure Cooling Nom. dBA 46 47 49 46 47 49
UNITS

level Heating Nom. dBA 48 50 52 48 50 52


Operation range Cooling Ambient Min.~Max. °CDB -20 ~52
Heating Ambient Min.~Max. °CWB -20 ~18
Refrigerant Type/GWP R-32/675
Charge kg/TCO2Eq 3.20/2.16 3.70/2.50 3.20/2.16 3.70/2.50
REFRIGERATION
COMMERCIAL &

Piping connections Liquid/Gas OD mm 9.52/15.9


TRANSPORT

Piping OU - IU Max. m 55 85 55 85
length System Equivalent m 75 100 75 100
Chargeless m 40
Level difference IU - OU Max. m 30
Additional refrigerant charge kg/m See installation manual
Power supply Phase/Frequency/Voltage Hz/V 1~/50 /220-240 3~/50 /380-415
Current - 50Hz Maximum fuse amps (MFA) A 20 32 16
CONTROL
SYSTEMS

Contains fluorinated greenhouse gases

433
FUA-A + RZASG-MV(1)/MY(1)

4-way blow ceiling


suspended unit
Unique Daikin unit for high rooms with no
false ceilings nor free floor space

› Combination with Sky Air Advance-series ensures good value for


money for all types of commercial applications
› Even rooms with ceilings up to 3.5m can be heated up or cooled FUA-A
down very easily without capacity loss
› Can easily be installed in both new and refurbishment projects
› Individual flap control: flexibility to suit every room layout without
changing the location of the unit!
› 5 different discharge angles between 0 and 60° can be
programmed via the remote control
› Stylish modern casing finished in pure white (RAL9010) and iron
grey (RAL7011) blends easily with any interior RZASG100-140MV(1)/MY(1) BRC1H52W, BRP069A81
› Optimum comfort guaranteed with automatic air flow adjustment
to the required load
› Standard drain pump with 720mm lift increases flexibility and
installation speed

More details and


final information
can be found by
scanning or clicking
the QR codes. FUA-A RZASG-MV1 RZASG-MY1 RZASG-MV RZASG-MY
Efficiency data FUA + RZASG 71A + 71MV1 100A + 100MV(1) 125A + 125MV(1) 100A + 100MY(1) 125A + 125MY(1)
Cooling capacity Nom. kW 6.80 9.50 12.1 9.50 12.1
Heating capacity Nom. kW 7.50 10.8 13.5 10.8 13.5
Space cooling Energy efficiency class A++ A+ - A+ -
Capacity Pdesign kW 6.80 9.50 12.1 9.50 12.1
SEER 6.16 5.83 5.49 5.83 5.49
ηs,c % - - 217 - 217
Annual energy consumption kWh/a 386 570 1,322 570 1,322
Space heating Energy efficiency class A A+ - A+ -
(Average climate) Capacity Pdesign kW 4.50 6.00
SCOP/A 3.90 4.01 3.84 4.01 3.84
ηs,h % - - 151 - 151
Annual energy consumption kWh/a 1,615 2,095 2,188 2,095 2,188
Indoor unit FUA 71A 100A 125A 100A 125A
Dimensions Unit HeightxWidthxDepth mm 198x950x950
Weight Unit kg 25.0 26.0
Air filter Type Resinnet
Fan Air flow Low/Medium/High m³/min
Cooling 16.0/19.5/23.0 20.0/25.5/31.0 20.5/26.5/32.5 20.0/25.5/31.0 20.5/26.5/32.5
rate Low/Medium/High m³/min
Heating 16.0/19.5/23.0 20.0/25.5/31.0 20.5/26.5/32.5 20.0/25.5/31.0 20.5/26.5/32.5
Sound power level Cooling dBA 59 64 65 64 65
Sound pressure Cooling Low/High dBA 35/41 39/46 40/47 39/46 40/47
level Heating Low/High dBA 35/41 39/46 40/47 39/46 40/47
Control systems Wired remote control BRC1H52W/S/K; BRC1E53A; BRC1E53B; BRC1E53C; BRC1D52
Piping connections Drain VP25 (OD Ø32.0)
Outdoor unit RZASG 71MV1 100MV(1) 125MV(1) 100MY(1) 125MY(1)
Dimensions Unit HeightxWidthxDepth mm 770x900x320 990x940x320
Weight Unit kg 60 70 (MV1/MY1) / 72 (MV/MY)
Sound power level Cooling dBA 65 69 71 69 71
Heating dBA - -
Sound pressure Cooling Nom. dBA 46 53 54 53 54
level Heating Nom. dBA 47 57 58 57 58
Operation range Cooling Ambient Min.~Max. °CDB -15 ~46 -15~46 -15~46 -15~46 -15~46
Heating Ambient Min.~Max. °CWB -15 ~15.5 -15~15.5 -15~15.5 -15~15.5 -15~15.5
Refrigerant Type/GWP R-32/675 R-32/675 R-32/675 R-32/675 R-32/675
Charge kg/TCO2Eq 2.45/1.65 2.60/1.76
Piping connections Liquid/ OD mm 9.52/15.9 9.52/15.9
Gas
Piping OU - IU Max. m 50 50
length System Equivalent m 70 70
Chargeless m 30 30
Level difference IU - OU Max. m 30.0 30.0
Additional refrigerant charge kg/m See installation See installation manual
manual
Power supply Phase/Frequency/Voltage Hz/V 1~/50 /220-240 1~/50 /220-240 3~/50 /380-415
Current - 50Hz Maximum fuse amps (MFA) A 20 25 32 16
Contains fluorinated greenhouse gases

434
INTRODUCTION
FVA-A + RZAG-NV1 / NY1

Floor standing unit

RESIDENTIAL
INDOOR AIR
QUALITY
For commercial spaces with high ceilings

› Combining with Sky Air Alpha-series ensures best in class quality,


highest efficiency and performance

HEATING
› Decrease of temperature variation by automatic fan speed
selection or freely selectable 3-step fan speed.
› Improved comfort as a result of better airflow distribution from
the vertical out blow which allows manual adjustment of air outlet RZAG-NV1_NY1
blades at the top of the unit.
› Selectable horizontal out blow to better suit the layout of the

SPLIT
room (via wired remote controller BRC1E*/BRC1H*)

Side view blades air outlet

All up Up

SKY AIR
BRC1H52W, BRP069A81 FVA-A
All down Down

ROOFTOP
More details and final information
can be found by scanning or
clicking the QR codes. FVA-A RZAG-NV1 RZAG-NY1
Efficiency data FVA + RZAG 71A + 71NV1 100A + 100NV1 125A + 125NV1 140A + 140NV1 71A + 71NY1 100A + 100NY1 125A + 125NY1 140A + 140NY1
Cooling capacity Nom. kW 6.80 9.50 12.1 13.4 6.80 9.50 12.1 13.4
Heating capacity Nom. kW 7.50 10.8 13.5 15.5 7.50 10.8 13.5 15.5

VRV
Space cooling Energy efficiency class A++ - A++ -
Capacity Pdesign kW 6.80 9.50 12.1 13.4 6.80 9.50 12.1 13.4
SEER 6.34 6.40 6.41 6.12 6.34 6.40 6.41 6.12
ηs,c % - 253 242 - 253 242

AIR PURIFICATION
Annual energy consumption kWh/a 376 520 1,133 1,314 376 520 1,133 1,314

VENTILATION &
COMMERCIAL
Space heating Energy efficiency class A+ - A+ -
(Average climate) Capacity Pdesign kW 4.70 7.80 9.52 4.70 7.80 9.52
SCOP/A 4.05 4.20 4.15 3.94 4.05 4.20 4.15 3.94
ηs,h % - 163 155 - 163 155
Annual energy consumption kWh/a 1,625 2,600 3,209 3,383 1,625 2,600 3,209 3,383
Indoor unit FVA 71A 100A 125A 140A 71A 100A 125A 140A

INDUSTRY
Dimensions Unit HeightxWidthxDepth mm 1,850x600x270 1,850x600x350 1,850x600x270 1,850x600x350

MARINE
Weight Unit kg 42 50 42 50
Air filter Type Resin net
Fan Air flow Cooling Low/Medium/ m³/min 14/16/18 22/25/28 24/26/28 26/28/30 14/16/18 22/25/28 24/26/28 26/28/30
rate High
Heating Low/Medium/ m³/min 14/16/18 22/25/28 24/26/28 26/28/30 14/16/18 22/25/28 24/26/28 26/28/30
High

CHILLERS
Sound power level Cooling dBA 55 62 63 65 55 62 63 65
Sound pressure Cooling Low/High dBA 38/43 44/50 46/51 48/53 38/43 44/50 46/51 48/53
level Heating Nom./High dBA 41/43 47/50 48/51 51/53 41/43 47/50 48/51 51/53
Control systems Wired remote control BRC1H52W/S/K / BRC1E53A / BRC1E53B / BRC1E53C / BRC1D52
Power supply Phase/Frequency/Voltage Hz/V 1~/50/60/220-240/220
Piping connections Drain I.D. 20/O.D. 26
FAN COIL

Outdoor unit RZAG 71NV1 100NV1 125NV1 140NV1 71NY1 100NY1 125NY1 140NY1
UNITS

Dimensions Unit HeightxWidthxDepth mm 870x1,100x460


Weight Unit kg 81 85 95 81 85 94
Sound power level Cooling dBA 64 66 69 70 64 66 69 70
Heating dBA - 68 71 - 68 71
Sound pressure Cooling Nom. dBA 46 47 49 50 46 47 49 50
AIR HANDLING

level Heating Nom. dBA 48 50 52 48 50 52


UNITS

Operation range Cooling Ambient Min.~Max. °CDB -20 ~52


Heating Ambient Min.~Max. °CWB -20 ~18
Refrigerant Type/GWP R-32/675
Charge kg/TCO2Eq 3.20/2.16 3.70/2.50 3.20/2.16 3.70/2.50
Piping connections Liquid/ OD mm 9.52/15.9
Gas
REFRIGERATION
COMMERCIAL &
TRANSPORT

Piping OU - IU Max. m 55 85 55 85
length System Equivalent m 75 100 75 100
Chargeless m 40
Level difference IU - OU Max. m 30
Additional refrigerant charge kg/m See installation manual
Power supply Phase/Frequency/Voltage Hz/V 1~/50 /220-240 3~/50 /380-415
Current - 50Hz Maximum fuse amps (MFA) A 20 32 16
CONTROL
SYSTEMS

Contains fluorinated greenhouse gases

435
FVA-A + RZASG-MV(1)/MY(1)

Floor standing unit


For commercial spaces with high ceilings

› Combination with Sky Air Advance-series ensures good value for


money for all types of commercial applications
› Decrease of temperature variation by automatic fan speed
selection or freely selectable 3-step fan speed.
› Improved comfort as a result of better airflow distribution from
the vertical out blow which allows manual adjustment of air outlet RZASG100-140MV(1)/MY(1)
blades at the top of the unit.
› Selectable horizontal out blow to better suit the layout of the
room (via wired remote controller BRC1E*/BRC1H*)

Side view blades air outlet

All up Up

BRC1H52W, BRP069C81 FVA-A


All down Down

More details and


final information
can be found by
scanning or clicking
the QR codes. FVA-A RZASG-MV1 RZASG-MY1 RZASG-MV RZASG-MY
Efficiency data FVA + RZASG 71A + 71MV1 100A + 100MV(1) 125A + 125MV(1) 140A + 140MV(1) 100A + 100MY(1) 125A + 125MY(1) 140A + 140MY(1)
Cooling capacity Min./Nom./Max. kW 6.80 9.50 12.1 13.4 9.50 12.1 13.4
Heating capacity Min./Nom./Max. kW 7.50 10.8 13.5 15.5 10.8 13.5 15.5
Space cooling Energy efficiency class A+ A+ - A+ -
Capacity Pdesign kW 6.80 9.50 12.1 13.4 9.50 12.1 13.4
SEER 5.83 5.72 5.52 5.63 5.72 5.52 5.63
ηs,c % - - 218 222 - 218 222
Annual energy consumption kWh/a 408 581 1,314 1,428 581 1,314 1,428
Space heating Energy efficiency class A+ A - A -
(Average climate) Capacity Pdesign kW 4.50 6.00 7.80 6.00 7.80
SCOP/A 4.04 3.83 3.64 3.81 3.83 3.64 3.81
ηs,h % - - 143 149 - 143 149
Annual energy consumption kWh/a 1,559 2,193 2,308 2,866 2,193 2,308 2,866
Indoor unit FVA 71A 100A 125A 140A 100A 125A 140A
Dimensions Unit HeightxWidthxDepth mm 1,850x600x270 1,850x600x350
Weight Unit kg 42 50
Air filter Type Resinnet
Fan Air flow Low/Medium/High m³/min
Cooling 14/16/18 22/25/28 24/26/28 26/28/30 22/25/28 24/26/28 26/28/30
rate Low/Medium/High m³/min
Heating 14/16/18 22/25/28 24/26/28 26/28/30 22/25/28 24/26/28 26/28/30
Sound power level Cooling dBA 55 62 63 65 62 63 65
Sound pressure Cooling Low/Medium/High dBA 38/41/43 44/47/50 46/48/51 48/51/53 44/47/50 46/48/51 48/51/53
level Heating Medium/Nom./High dBA 38/41/43 44/47/50 46/48/51 48/51/53 44/47/50 46/48/51 48/51/53
Control systems Wired remote control BRC1H52W/S/K / BRC1E53A / BRC1E53B / BRC1E53C / BRC1D52
Power supply Phase - Frequency - Voltage Hz - V 1~ - 50/60 - 220-240/220
Outdoor unit RZASG 71MV1 100MV(1) 125MV(1) 140MV(1) 100MY(1) 125MY(1) 140MY(1)
Dimensions Unit HeightxWidthxDepth mm 770x900x320 990x940x320
Weight Unit kg 60 70 (MY1) / 72 (MY) 78 (MV1) / 79 (MV) 70 (MY1) / 72 (MY) 78 (MV1) / 79 (MV)
Sound power level Cooling dBA 65 70 71 73 70 71 73
Heating dBA - 71 73 - 71 73
Sound pressure Cooling Nom. dBA 46 53 54 53 54
level Heating Nom. dBA 47 57
Operation range Cooling Ambient Min.~Max. °CDB -15~46
Heating Ambient Min.~Max. °CWB -15~15.5
Refrigerant Type/GWP R-32/675
Charge kg/TCO2Eq 2.45/1.65 2.60/1.76 2.90/1.96 2.60/1.76 2.90/1.96
Piping connections Liquid/Gas OD mm 9.52/15.9
Piping OU - IU Max. m 50
length System Equivalent m 70
Chargeless m 30
Additional refrigerant charge kg/m See installation manual
Level difference IU - OU Max. m 30.0
Power supply Phase/Frequency/Voltage Hz/V 1~/50 /220-240 3~/50 /380-415
Current - 50Hz Maximum fuse amps (MFA) A 20 25 32 16
Contains fluorinated greenhouse gases

436
INTRODUCTION
NEW FVA-A + AZAS-MV/MY

Floor standing unit

RESIDENTIAL
INDOOR AIR
QUALITY
For commercial spaces with high ceilings

› Ideal solution for small businesses and shops


› Decrease of temperature variation by automatic fan speed

HEATING
selection or freely selectable 3-step fan speed.
› Improved comfort as a result of better airflow distribution from
the vertical out blow which allows manual adjustment of air outlet
blades at the top of the unit. AZAS-MV/MY
› Selectable horizontal out blow to better suit the layout of the
room (via wired remote controller BRC1E*/BRC1H*)

SPLIT
Side view blades air outlet

All up Up

SKY AIR
BRC1H52W, BRP069A81 FVA-A
All down Down

ROOFTOP
More details and final information
can be found by scanning or
clicking the QR codes. FVA-A AZAS-MV AZAS-MY

VRV
Efficiency data FVA + AZAS 100A + 100MV 125A + 125MV 140A + 140MV 100A + 100NY 125A + 125NY 140A + 140NY
Cooling capacity Nom. kW 9.50 12.1 13.4 9.50 12.1 13.4
Heating capacity Nom. kW 10.8 13.5 15.5 10.8 13.5 15.5
Space cooling Energy efficiency class A - A -
Capacity Pdesign kW 9.50 12.1 13.4 9.50 12.1 13.4

AIR PURIFICATION
VENTILATION &
COMMERCIAL
SEER 5.5 5.3 5.4 5.5 5.3 5.4
ηs,c % - 209 213 - 209 213
Annual energy consumption kWh/a 605 1,370 1,489 605 1,370 1,489
Space heating Energy efficiency class A - A -
(Average climate) Capacity Pdesign kW 6.00 7.80 6.00 7.80
SCOP/A 3.79 3.56 3.81 3.79 3.56 3.81
ηs,h % - 139 149 - 139 149

INDUSTRY
Annual energy consumption kWh/a 2,217 2,360 2,866 2,217 2,360 2,866

MARINE
Indoor unit FVA 100A 125A 140A 100A 125A 140A
Dimensions Unit HeightxWidthxDepth mm 1,850x600x350 1,850x600x350
Weight Unit kg 50 50
Air filter Type Resin net
Fan Air flow Low/Medium/High m³/min
Cooling 22/25/28 24/26/28 26/28/30 22/25/28 24/26/28 26/28/30
rate Low/Medium/High m³/min
Heating 22/25/28 24/26/28 26/28/30 22/25/28 24/26/28 26/28/30

CHILLERS
Sound power level Cooling dBA 62 63 65 62 63 65
Sound pressure Cooling Low/High dBA 44/50 46/51 48/53 44/50 46/51 48/53
level Heating Nom./High dBA 47/50 48/51 51/53 47/50 48/51 51/53
Control systems Wired remote control BRC1H52W/S/K / BRC1E53A / BRC1E53B / BRC1E53C / BRC1D52
Power supply Phase/Frequency/Voltage Hz/V 1~/50/60/220-240/220
Piping connections Drain I.D. 20/O.D. 26
FAN COIL
UNITS

Outdoor Unit AZAS 100MV 125MV 140MV 100MY 125MY 140MY


Dimensions Unit HeightxWidthxDepth mm 990x940x320
Weight Unit kg 72 79 72 79
Sound power level Cooling dBA 70 71 72 70 71 72
Heating dBA 70 71 72 70 71 72
AIR HANDLING

Sound pressure Cooling Nom. dBA 53 54 55 53 54 55


level Heating Nom. dBA 57 58 59 57 58 59
UNITS

Operation range Cooling Ambient Min.~Max. °CDB -10~46


Heating Ambient Min.~Max. °CWB -15~15.5
Refrigerant Type/GWP R-32/675
Charge kg/TCO2Eq 2.60/1.76 2.90/1.96 2.60/1.76 2.90/1.96
Piping connections Liquid/Gas OD mm 9.52/15.9
REFRIGERATION
COMMERCIAL &
TRANSPORT

Piping OU - IU Max. m 30
length System Equivalent m 50
Chargeless m 30
Additional refrigerant charge kg/m See installation manual
Level difference IU - OU Max. m 30.0
Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240 3~/50/380-415
Current - 50Hz Maximum fuse amps (MFA) A 25 32 16
CONTROL
SYSTEMS

Contains fluorinated greenhouse gases

437
FNA-A9 + RZAG-A

Concealed floor standing unit


Designed to be concealed in walls

› Combination with Sky Air Alpha-series ensures best in class


quality, highest efficiency and performance
› Discretely concealed in the wall: only the suction and discharge
grilles are visible
› Requires very little installation space as the depth is only 200mm
› Its low height (620 mm) enables the unit to fit perfectly beneath a FNA-A9
window
› High ESP allows flexible installation

RZAG35-60A BRC1H52W BRP069C81

More details and final information


can be found by scanning or
clicking the QR codes. FNA-A9 RZAG-A
Efficiency data FNA + RZAG 35A9 + 35A 50A9 + 50A 60A9 + 60A
Cooling capacity Min./Nom./Max. kW 1.6/3.5/4.5 1.7/5.0/6.0 1.7/6.0/6.5
Heating capacity Min./Nom./Max. kW 1.40/4.00/5.00 1.70/5.00/6.00 1.70/7.00/7.50
Space cooling Energy efficiency class A+
Capacity Pdesign kW 3.50 5.00 6.00
SEER 5.90 5.70
Annual energy consumption kWh/a 208 297 368
Space heating Energy efficiency class A
(Average climate) Capacity Pdesign kW 3.50 4.30 4.50
SCOP/A 3.90
Annual energy consumption kWh/a 1,255 1,542 1,616
Indoor unit FNA 35A9 50A9 60A9
Dimensions Unit HeightxWidthxDepth mm 620/720x790x200 620/720x1,190x200
Weight Unit kg 23.0 30.0
Air filter Type Resin net
Fan Air flow Cooling Low/High m³/min 7.3/8.7 13.5/16.0
rate Heating Low/High m³/min 7.3/8.7 13.5/16.0
External static Nom./High Pa 30/48 40/49
pressure
Sound power level Cooling dBA 53.0 56.0
Sound pressure Cooling Low/Medium/High dBA 28.0/31.0/33.0 30.0/33.0/36.0
level Heating Low/Nom./High dBA 28.0/31.0/33.0 30.0/33.0/36.0
Control systems Infrared remote control BRC4C65
Wired remote control BRC1H52W/S/K / BRC1E53A / BRC1E53B / BRC1E53C / BRC1D52
Power supply Phase/Frequency/Voltage Hz/V 1~/50/60/220-240/220
Outdoor unit RZAG 35A 50A 60A
Dimensions Unit HeightxWidthxDepth mm 734x870x373
Weight Unit kg 52
Sound power level Cooling dBA 62.0 63.0 64.0
Heating dBA 62.0 63.0 64.0
Sound pressure Cooling Nom. dBA 48.0 49.0 50.0
level Heating Nom. dBA 48.0 49.0 50.0
Operation range Cooling Ambient Min.~Max. °CDB -20~52
Heating Ambient Min.~Max. °CWB -20~24
Refrigerant Type/GWP R-32/675.0
Charge kg/TCO2Eq 1.55/1.05
Piping connections Liquid/Gas OD mm 6.35/9.52 6.35/12.7
Piping OU - IU Max. m 50
length System Chargeless m 30
Additional refrigerant charge kg/m 0.02 (for piping length exceeding 30m)
Level difference IU - OU Max. m 30.0
Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240
Contains fluorinated greenhouse gases

438
INTRODUCTION
FNA-A9 + RXM-R(9)/A Split

Concealed floor standing unit

RESIDENTIAL
INDOOR AIR
QUALITY
Designed to be concealed in walls

› Combination with split outdoor units is ideal for small retail,


offices and residential applications

HEATING
› Discretely concealed in the wall: only the suction and discharge
grilles are visible
› Requires very little installation space as the depth is only 200mm
› Its low height (620 mm) enables the unit to fit perfectly beneath a FNA-A9
window
› High ESP allows flexible installation

SPLIT
SKY AIR
RXM-R BRC1H52W BRP069C81

More details and final information


can be found by scanning or
clicking the QR codes. FNA-A9 RXM-R RXM-R9 RXM-A

ROOFTOP
Efficiency data FNA + RXM 25A9 + 25R9 35A9 + 35R9 50A9 + 50A 60A9 + 60R
Cooling capacity Nom. kW 2.60 3.40 5.00 6.00
Heating capacity Nom. kW 3.20 4.00 5.80 7.00
Power input Cooling Nom. kW 0.68 1.10 1.48 2.22
Heating Nom. kW 0.80 1.15 1.74 2.25
Space cooling Energy efficiency class A+ A

VRV
Capacity Pdesign kW 2.60 3.40 5.00 6.00
SEER 5.68 5.70 5.77 5.56
Annual energy consumption kWh/a 160 209 303 378
Space heating Energy efficiency class A+
(Average climate) Capacity

AIR PURIFICATION
Pdesign kW 2.80 2.90 4.00 4.60

VENTILATION &
COMMERCIAL
SCOP/A 4.24 4.05 4.09 4.16
Annual energy consumption kWh/a 924 1,002 1,368 1,547
Nominal efficiency EER 3.80 3.09 3.38 2.70
COP 4.00 3.48 3.34 3.11
Annual energy consumption kWh 342 550 740 1,111
Energy labeling Directive Cooling/Heating A/A B/B A/C D/D
Indoor unit FNA 25A9 35A9 50A9 60A9

INDUSTRY
MARINE
Dimensions Unit HeightxWidthxDepth mm 620/720x790x200 620/720x1,190x200
Weight Unit kg 23.0 30.0
Air filter Type Resinnet
Fan Air flow Cooling Low/High m³/min 7.3/8.7 13.5/16.0
rate Heating Low/High m³/min 7.3/8.7 13.5/16.0
External static Nom./High Pa 30/48 40/49
pressure

CHILLERS
Sound power level Cooling dBA 53.0 56.0
Sound pressure Cooling Low/Medium/High dBA 28.0/31.0/33.0 30.0/33.0/36.0
level Heating Low/Nom./High dBA 28.0/31.0/33.0 30.0/33.0/36.0
Control systems Infrared remote control BRC4C65
Wired remote control BRC1H52W/S/K / BRC1E53A / BRC1E53B / BRC1E53C / BRC1D52
Power supply Phase/Frequency/Voltage Hz/V 1~/50/60/220-240/220
FAN COIL
UNITS

NEW
Outdoor unit RXM 25R9 35R9 50A 60R
Dimensions Unit HeightxWidthxDepth mm 552x840x350 734x954x401
Weight Unit kg 32 49.0
Sound pressure Cooling Nom. dBA 46.0 49.0 48.0
AIR HANDLING

level Heating Nom. dBA 47.0 49.0


Operation range Cooling Ambient Min.~Max. °CDB -10~46
UNITS

Heating Ambient Min.~Max. °CWB -15~18


Refrigerant Type R-32
GWP 675 675.0
Charge kg/TCO2Eq 0.76/0.52 1.15/0.780
Piping connections Liquid OD mm 6.35
REFRIGERATION
COMMERCIAL &
TRANSPORT

Gas OD mm 9.52 12.7


Piping OU - IU Max. m 20 30
length System Chargeless m 10
Additional refrigerant charge kg/m 0.02 (for piping length exceeding 10m)
Level difference IU - OU Max. m 15 20.0
Power supply Phase/Frequency/Voltage Hz/V 1~/50 /220-240
Current - 50Hz Maximum fuse amps (MFA) A 13 16
CONTROL
SYSTEMS

Contains fluorinated greenhouse gases

439
Benefits of Biddle air curtains
› Connectable to ERQ and VRV units
› Unified range for R-32 and R-410A refrigerant
› payback period of less then 1.5 years compared to installing an
electric air curtain
electric air
curtain

(installation + running cost) in €


12,000

10,000

8,000

total cost
Daikin heat pump
6,000
with Biddle air curtain
4,000

2,000

0
1 2 years

3 different models to choose from:

Free-hanging model (F):


easy wall mounted installation

Cassette model (C):


mounted into a false ceiling leaving
only the decoration panel visible

Recessed model (R):


neatly concealed in the ceiling

Select your Biddle air curtain range


3.0m
3 2.75m
Door 2.5m 2.4m 2.5m
2.3m 2.3m
height (m) 2.15m
2.0m
2

S M L S M L S M L

Installation Favourable Normal Unfavourable

Biddle air condition ex: covered shopping


mall or revolving
door entrance
ex: little direct wind,
no opposite open
doors, building with
ex: location at a
corner or square,
multiple floors

curtains ground floor only and / or open


stairwell

Biddle air curtains provide Biddle air curtain nomenclature


CYA S 150 DK 80 F S N
highly efficient solutions for No Biddle controller

retailers and consultants to Color


B = White (RAL 9016)
S = Grey (RAL 9006)
F = Free hanging
combat the issue of climate Installation type C = Cassette
R = Recessed

separation across their outlet or Capacity class (kW)

Daikin direct expansion


office doorway.
Door width (cm)

Range S = Small M = Medium L = Large


Biddle air curtain for ERQ and VRV
Unified model for R-32 and R-410A

440
INTRODUCTION
NEW CYA-S/M/L-DK-F/C/R
New R-32
range
Biddle air curtain

RESIDENTIAL
INDOOR AIR
QUALITY
› Connectable to ERQ and VRV DX outdoor units
› Unified model for R-32 and R-410A refrigerant
› Free-hanging model (F): easy wall mounted installation
› Cassette model (C): mounted into a false ceiling leaving only the

HEATING
decoration panel visible
› Recessed model (R): neatly concealed in the ceiling
› A payback period of less then 1.5 years compared to installing an electric
air curtain CYA150DK80FSC
› Provides virtually free air curtain heating via recovered heat from indoor
units in cooling mode (in case of VRV heat recovery)
› Easy and quick to install at reduced costs since no additional water

SPLIT
systems, boilers and gas connections are required

SKY AIR
CYA150DK80CSC CYA150DK80RSC

NETWORK SOLUTION VRV

ROOFTOP
More details and final information
can be found by scanning or
clicking the QR codes. CYA
BIDDLE COMFORT AIR CURTAIN (CA)
Small Medium
CYAS100DK80* CYAS150DK80* CYAS200DK100* CYAS250DK140* CYAM100DK80* CYAM150DK80* CYAM200DK100* CYAM250DK140*
Heating capacity Speed 3 kW 6,94 8,6 10,9 15,2 8,65 10,5 12,5 18,6

VRV
Power input Fan only Nom. kW 0,14 0,21 0,28 0,36 0,27 0,40 0,53 0,67
Heating Nom. kW 0,14 0,21 0,28 0,36 0,27 0,40 0,53 0,67
Delta T Speed 3 K 17,7 14,6 13,9 15,5 16 12,9 12,7 13,8
Casing Colour B: RAL9016 / S: RAL9006 B: RAL9016 / S: RAL9006

AIR PURIFICATION
VENTILATION &
Dimensions Unit Height F/C/R mm 270/270/270 270/270/270

COMMERCIAL
Width F/C/R mm 1000/1000/1048 1500/1500/1548 2000/2000/2048 2500/2500/2548 1000/1000/1048 1500/1500/1548 2000/2000/2048 2500/2500/2548
Depth F/C/R mm 590/821/561 590/821/561
Required ceiling void > mm mm 420 420
Door height Max. m 2,3 2,5
Door width Max. m 1 1,5 2 2,5 1 1,5 2 2,5
Weight Unit kg 56/59/61 66/83/88 83/102/108 107/129/137 57/68/66 73/88/93 94/111/117 108/136/144
Fan Speed 3 m³/h 1164 1746 2328 2910 1605 2408 2910 4013

INDUSTRY
Sound pressure level Heating Speed 3 dBA 47 49 50 51 50 51 53 54

MARINE
Refrigerant GWP 675/2087,5 675/2087,5
Type R32/R410A R32/R410A
Piping connections Liquid OD mm 6,35 9,52 6,35 9,52
Gas OD mm 12,7 15,9 12,7 15,9
Air filter Type Vacuum cleanable filter G1
Power supply Frequency Hz 50Hz 50Hz
Voltage V 230V 230V

CHILLERS
Maximum fuse amps (MFA) A 16 16

Large
CYAL100DK125* CYAL150DK200* CYAL200DK250* CYAL250DK250*
Heating capacity Speed 3 kW
14,4 21,5 27,6 29,7
Power input Fan only Nom. kW 0,48 0,72 0,96 1,20
FAN COIL

Heating Nom. kW 0,48 0,72 0,96 1,20


UNITS

Delta T Speed 3 K 13,8 13,7 13,2 11,4


Casing Colour B: RAL9016 / S: RAL9006
Dimensions Unit Height F/C/R mm 370/370/370
Width F/C/R mm 1000/1000/1048 1500/1500/1548 2000/2000/2048 2500/2500/2548
Depth F/C/R mm 774/1105/745
AIR HANDLING

Required ceiling void > mm mm 520


Door height Max. m 3
UNITS

Door width Max. m 1 1,5 2 2,5


Weight Unit kg 76/81/83 100/118/141 126/151/155 157/190/196
Fan Speed 3 m³/h 3100 4650 6200 7750
Sound pressure level Heating Speed 3 dBA 53 54 56 57
Refrigerant GWP 675/2087,5
REFRIGERATION
COMMERCIAL &

Type R32/R410A
TRANSPORT

Piping connections Liquid OD mm 9,522


Gas OD mm 15,9 19,1 19,1
Air filter Type Vacuum cleanable filter G1
Power supply Frequency Hz 50Hz
Voltage V 230V
Current Maximum fuse amps A
16
(MFA)
CONTROL
SYSTEMS

441
SKY AIR ALPHA-SERIES - LOW HEIGHT UNIT

LOW SOUND ENCLOSURE FOR SKY AIR


ALPHA-SERIES (RZAG-N) AND ADVANCE-SERIES (RZA-D)

442
INTRODUCTION
RESIDENTIAL
INDOOR AIR
QUALITY
HEATING
A range of industry
­leading technology

SPLIT
outdoor units
Products overview outdoor units 444
Benefits overview outdoor units 445

SKY AIR
446
Low sound enclosure 447
Variable Refrigerant Temperature 448

Outdoor Replacement technology 449

ROOFTOP
units RZAG-A
range
450
450

RZAG-NV1/NY1 450
RZASG-MV(1)/MY(1) 451

VRV
RZA-D 452
ARXM-R/
AZAS-MV/MY 453

AIR PURIFICATION
VENTILATION &
COMMERCIAL
Multi model and VRV range
See Split or VRV chapter
Options & Accessories 454

INDUSTRY
MARINE
CHILLERS
FAN COIL
UNITS

Pair solution Twin, triple, double twin solution


AIR HANDLING
UNITS
REFRIGERATION
COMMERCIAL &
TRANSPORT
CONTROL
SYSTEMS

443
Outdoor units

Products overview outdoor units

Low height.
High value.

Pair, twin, triple & double twin application


Product
System Type Model 35 50 60 71 100 125 140 200 250
name
3.5 kW 5.0 kW 6.0 kW 6.8 kW 9.5 kW 12.1 kW 13.4 kW 21.5 kW 23.6 kW

- Industry leading technology for commercial applications RZAG-A


- Dedicated solution for infrastructure cooling (A+++ - D) RZAG-
- Variable Refrigerant Temperature (RZAG71-100-125-140 series) NV1/NY1
- Maximum piping length up to 85m (50m for RZAG35-50-60)
- Replacement technology
- Extended operation range down to -20°C in both heating and cooling
- Pair, twin, triple and double twin application (RZAG71-100-125-140 series)

RZASG-
MV(1)/
Air Heat MY(1)
cooled pump - Technology and comfort combined for commercial applications
- Very compact and easy to install outdoor units (A+++ - D)
- Maximum piping length up to 50m (RZA-D up to 100m)
- Replacement technology
- Operation range down to -15°C both cooling and in heating (RZA-D down to -20°C) RZA-D
- Pair, twin, triple and double twin application

- Ideal solution for busy environments and small shops ARXM-R


- Very compact and easy to install outdoor units AZAS-
- Maximum piping length up to 30m
(A+++ - D) MV/MY
- Replacement technology
- Easy-to-mount outdoor units: roof, terrace or wall
- Exclusively offered for pair applications

444
INTRODUCTION
Outdoor units

Benefits overview outdoor units

RESIDENTIAL
INDOOR AIR
QUALITY
RZASG-
RZAG-A RZAG-NV1/NY1 RZA-D AZAS-MV/MY ARXM-R(9)
MV(1)/MY(1)

HEATING
Seasonal efficiency gives a more realistic
Seasonal efficiency - indication on how efficient air conditioners
Smart use of energy operate over an entire heating or cooling (A+++ - D) (A+++ - D) (A+++ - D)
-
(A+++ - D) (A+++ - D)
season.
We care icons

Inverter compressors continuously adjust


compressor speed to actual demand. Fewer
Inverter technology power-consuming starts and stops result in      

SPLIT
decreased energy consumption (up to 30%)
and more stable temperatures.
Quick and quality system replacement in the
Replacement
technology most cost effective way      
Lowers the operation sound of the outdoor unit
Night quiet      
Comfort

SKY AIR
automatically.
Auto cooling-heating Automatically selects cooling or heating mode
changeover to achieve the set temperature.      
The intelligent systems ensures highest energy
Variable refrigeration
temperature
savings with additional comfort to better suit
application requirements.

ROOFTOP
2, 3 or 4 indoor units can be connected to only
1 outdoor unit. All indoor units operate within
Twin/triple/double
twin application the same mode (cooling or heating) from one   
Other functions

remote control.
Outdoor units are fitted with a swing
Swing compressor compressor, renowned for its low noise and
high reliability
     

VRV
Guaranteed Daikin is suitable for all climates, even
operation
down to -20°C
withstanding severe winter conditions with an
operation range down to -20°C.
  
For high sensible, infrastructure cooling
applications, dedicated infrastructure
 

AIR PURIFICATION
VENTILATION &
Infrastructure cooling

COMMERCIAL
cooling settings and allowing asymmetric
combinations enhance the system’s reliability.
Dedicated Daikin developed and tested low
Low sound enclosure sound enclosure, reducing sound power by up
to -10 dB(A)
• •

INDUSTRY
MARINE
Technical benefit overview

CHILLERS
RZASG-
RZAG-A RZAG-NV1/NY1 RZA-D AZAS-MV/MY ARXM-R(9)
MV(1)/MY(1)
Compact single fan casing on the entire range      
Maximum piping length 50 m 85 m 50 m 100 m 30 m 30 m

Pivoting front plate  


    
FAN COIL

7 segment display
UNITS

Increased factory charge  


Integrated leak check 
Refrigerant bottom plate pass 
AIR HANDLING

Specially deveoloped R-32 swing compressor      


UNITS

Refrigerant cooled PCB     


Intelligent Tablet controller - Onecta app • • • • • •
• standard, • optional
REFRIGERATION
COMMERCIAL &
TRANSPORT
CONTROL
SYSTEMS

445
Low height.
High value.

Unique, low-height
single fan range

Compact unit, 1,100 mm

easy to transport
870 mm

Market-leading
serviceability
and handling

Fast and easy access to all Newly positioned handle


critical component for easier carrying
› Single screw access
› Wider access area

446
INTRODUCTION
Low sound enclosure

RESIDENTIAL
INDOOR AIR
QUALITY
EKLN140A

HEATING
SPLIT
– 10 dB(A)!

SKY AIR
Benefits
Dedicated Daikin option for: Easy to integrate
› Sky Air Alpha-series › Anthracite (RAL 7016), highly aesthetic finishing

ROOFTOP
› Sky Air Advance-series › Mechanically designed to perfectly suit the Sky Air Alpha/
› VRV 5 S-series Advance and VRV 5 S-series casings
› Self-supporting; can be installed on any flat surface
Fully optimised and tested in Daikin factory
› Guaranteed performance levels Fast & easy installation & servicing
(sound, capacity, efficiency) › 100 % weather resistant
› Easy opening to access most system components

VRV
Outdoor unit sound reduction of up to
-10 dB(A) on sound power levels Durable
› Enabling to meet local sound requirements › 3 years warranty on all components

AIR PURIFICATION
› Increased flexibility to apply outdoor units › Made of stainless steel with robust double layer powder

VENTILATION &
COMMERCIAL
› Reduces sound on the entire sound spectrum coating, ensuring maximum corrosion resistance

Minimal capacity reduction


› Separated air intake and discharge to prevent air flow short circuit
› No additional calculations needed thanks to factory tested data

INDUSTRY
MARINE
Tried and tested:
values that you can rely on

CHILLERS
Our low sound enclosure eliminates possible
problems and reduces your workload significantly:

› No incompatibilities – tested combinations


with the outdoor unit that you want to encase
› No surprises – measured and guaranteed
FAN COIL
UNITS

sound reduction according to ISO 3744


› No calculations – tested performance values
for capacity and efficiency
Sound power level measurement in acoustic chamber
AIR HANDLING
UNITS

Sound enclosure EKLN140A


Casing Colour Anthracite (RAL 7016)
Material Sheet metal
Dimensions Unit Height mm 1,100
Width mm 1,400
REFRIGERATION
COMMERCIAL &

Depth mm 1,500
TRANSPORT

Packed unit Height mm 1,017


Width mm 1,517
Depth mm 917
Weight Unit kg 152
Packed unit kg 186
Combines with Sky Air Alpha-series RZAG-NV1/NY1
Sky Air Advance-series RZA-D
CONTROL
SYSTEMS

VRV 5 S-series RXYSA-AV1/AY1

447
Outdoor units

Variable Refrigerant
Temperature

The ultimate customer experience


Increases air discharge temperature
and eliminates cold drafts!

Increased customer comfort and


reduced energy consumption!

› The system automatically increases its evaporating Min. Te1 Depending on the gap between
indoor t° and set point the Te
temperature (Te) when the gap between the actual will be increased or decreased
indoor temperature (Tin) and the setpoint (Tset) is Lin
ear
Te
becoming smaller, increasing comfort and provi- li mit
ding more stable operation Min. Te2

20° 31° Ta
Outdoor t° trigger values
Quick cooling
(selected on remote control)

Case study: JBC, Vilvoorde


Two pair systems are installed in the
same zone allowing comparison

More energy efficient:


up to 20% lower energy consumption
With VRT

Average energy consumption over 5 months No VRT

of operation

Apr May Jun Jul Aug

Td
Improved comfort:
higher discharge temperatures
With VRT
› More stable and continuous operation No VRT
› Average discharge temperature increased with 3~4°C

448
INTRODUCTION
Outdoor units

RESIDENTIAL
INDOOR AIR
QUALITY
Replacement technology

HEATING
The quick and quality way of upgrading R-22 and R-410A systems

SPLIT
Benefits to increase The benefits will convince your customer
your profit

SKY AIR
To prevent unexpected breakdown
Optimise your business
To lower running costs
Less installation time
To protect the environment

ROOFTOP
Tackle more projects in less time thanks to faster
installation. It is more profitable than replacing the
full system with new piping. To improve comfort

Lower installation costs


Reducing installation costs enables you to offer cus-
tomers the most cost-effective solution and improve Your copper pipes will last for multiple generations

VRV
your competitive edge.
- c opper pipes used in air conditioning systems tested by Daikin
Replace non-Daikin systems will last over 60 years after installation.

AIR PURIFICATION
VENTILATION &
COMMERCIAL
It is a trouble-free replacement solution for
Daikin systems and for systems made by other
manufacturers.

Easy as one-two-three

INDUSTRY
MARINE
A simple solution for replacement technology
enables you to handle more projects for more
customers in less time and offer them the best price!
Everybody gains.

CHILLERS
How does it work? Unique technologies
› Cleaning free piping re-usage thanks to unique hepta filtering for maximum
The Daikin low-cost upgrade solution particle reduction

! Replace indoor units


FAN COIL
UNITS

Contact your local dealer to check compatibility in 1 2 3 4 1 2 3 4


case you need to keep the indoor units.
AIR HANDLING
UNITS

HPS-A
LPS


REFRIGERATION
COMMERCIAL &

Replace outdoor units


TRANSPORT

› New expansion valve needle material,


Learn more about Daikin replacement solutions at
with high corrosion resistance
www.daikin.eu/en_us/knowledge-center/
replacement-technology.html › New type oil for maximum system protection
CONTROL
SYSTEMS

449
RZAG-A / NV1 / NY1

Sky Air Alpha-series


Industry leading technology for commercial
applications and even for technical rooms

› Unique, low-height single fan range


› Compact dimensions allow almost unoticeable installation
› Market-leading serviceability and handling, thanks to wide access
area, 7-segment display and additional handle
› The perfect balance in efficiency and comfort thanks to Variable
Refrigerant Temperature: top seasonal efficiency throughout most
of the year and quick reaction speed on the hottest days.
› Suits high sensible, infrastructure cooling applications
› Replace existing systems with R-32 technology without needing to
replace the piping
› Guarantees operation in both heating and cooling mode down to
-20°C
› Refrigerant cooled PCB guarantees reliable cooling, as it is not RZAG-NV1_NY1
influenced by ambient temperature.
› Maximum piping length up to 85m (50m for RZAG-A)
› Outdoor units for pair, twin, triple, double twin application
› Combines with EKLN-A low sound enclosure

Comfort cooling combination table


FCAHG-H

FDXM-F9

FHA-A(9)
FBA-A(9)

FTXM-R

FNA-A9
FCAG-B

FFA-A9

FDA-A

FUA-A

FVA-A
FAA-B
capacity class 71 100 125 140 35 50 60 71 100 125 140 35 50 60 125 35 50 60 35 50 60 71 100 125 140 35 50 60 71 100 125 140 71 100 35 50 60 71 71 100 125 35 50 60 71 100 125 140
RZAG35A P P P P P P P
RZAG50A P P P P P P P
RZAG60A P P P P P P P
RZAG71NV1 RZAG71NY1 P 2 P 2 2 2 P 2 P P P 2 P
RZAG100NV1 RZAG100NY1 P 3 2 P 3 2 3 2 3 2 P 3 2 P P P 3 2 P
RZAG125NV1 RZAG125NY1 P 4 3 2 P 4 3 2 P 4 3 2 4 3 2 P 4 3 2 P P 4 3 2 P
RZAG140NV1 RZAG140NY1 2 P 4 3 2 P 4 3 4 3 4 3 2 P 4 3 2 P 2 2 4 3 2 P
P = pair application; 2/3/4 = twin/triple/double twin application

Infrastructure cooling combination table


FCAHG-H
FDXM-F9
FHA-A(9)

FBA-A(9)
FTXM-R

FNA-A9

FCAG-B
FFA-A9
FUA-A

FVA-A
FAA-B

capacity class 35 50 60 71 71 100 35 50 60 71 100 125 140 35 50 60 71 100 125 140 35 50 60 71 100 125 35 50 60 71 100 125 140 35 50 60 71 100 125 140 35 50 60 71 100 125 140
RZAG35A P P P P P P P
RZAG50A P P P P P P P
RZAG60A P P P P
RZAG71NV1 RZAG71NY1 P 3 2 P 3 2 P 3 2 P 3 2 P 3 2 P 3 2 P
RZAG100NV1 RZAG100NY1 2 4 3 2 P 4 3 2 P 4 3 2 4 3 P 4 3 2 P 4 3 2 P
RZAG125NV1 RZAG125NY1 2 4 3 2 P 4 3 2 P 4 3 2 4 3 P 4 3 2 P 4 3 2 P
RZAG140NV1 RZAG140NY1 2 4 3 2 P 4 3 2 P 4 3 2 4 3 P 4 3 2 P 4 3 2 P
P = Pair, 2 = Twin, 3 = Triple, 4 = Double twin; For more information on infrastructure cooling options refer to infrastructure cooling catalogue.

More details and final information


can be found by scanning or
clicking the QR codes. RZAG-A RZAG-NV1 RZAG-NY1
Outdoor unit RZAG 35A 50A 60A 71NV1 100NV1 125NV1 140NV1 71NY1 100NY1 125NY1 140NY1
Dimensions Unit HeightxWidthxDepth mm 734x870x373 870x1,100x460
Weight Unit kg 52 81 85 95 81 85 94
Sound power level Cooling dBA 62.0 63.0 64.0 64 66 69 70 64 66 69 70
Heating dBA 62.0 63.0 64.0 - 68(1) 71(1) - 68(1) 71(1)
Sound pressure Cooling Nom. dBA 48.0 49.0 50.0 46 47 49 50 46 47 49 50
level Heating Nom. dBA 48.0 49.0 50.0 48 50 52 48 50 52
Operation range Cooling Ambient Min.~Max. °CDB -20~52 -20~52
Heating Ambient Min.~Max. °CWB -20~24 -20~18
Refrigerant Type/GWP R-32/675.0 R-32/675
Charge kg/TCO2Eq 1.55/1.05 3.20/2.16 3.70/2.50 3.20/2.16 3.70/2.50
Piping connections Liquid/Gas OD mm 6.35/9.52 6.35/12.7 9.52/15.9
Piping OU - IU Max. m 50 55 85 55 85
length System Equivalent m - 75 100 75 100
Chargeless m 30 40
Level difference IU - OU Max. m 30.0 30
Additional refrigerant charge kg/m 0.02 (for piping length exceeding 30m) See installation manual
Power supply Phase/Frequency/Voltage Hz/V 1~/50 /220-240 3~/50 /380-415
Current - 50Hz Maximum fuse amps (MFA) A - 20 32 16
(1)According to ENER Lot 21 | Contains fluorinated greenhouse gases

450
INTRODUCTION
RZASG-MV(1)/MY(1)

Sky Air Advance-series

RESIDENTIAL
INDOOR AIR
QUALITY
Technology and comfort combined
for commercial applications

› High efficiency:

HEATING
- Energy labels up to A++ (cooling) / A+ (heating)
- Compressor offers substantial efficiency improvements
› Very compact and easy to install
› Replace existing systems with R-32 technology without needing to
replace the piping
› Guarantees operation in both heating and cooling mode down to

SPLIT
-15°C
› Refrigerant cooled PCB guarantees reliable cooling, as it is not
influenced by ambient temperature.
› Maximum piping length up to 50m, minimum piping length has
no limitation

SKY AIR
› Outdoor units for pair, twin, triple, double twin application RZASG100-140MV(1)/MY(1)

ROOFTOP
VRV
Pair, twin, triple and double twin application

FCAG-B FFA-A9 FDXM-F9 FBA-A(9)

AIR PURIFICATION
VENTILATION &
capacity class 35 50 60 71 100 125 140 35 50 60 35 50 60 35 50 60 71 100 125 140

COMMERCIAL
RZASG71MV1 2 P 2 2 2 P
RZASG100MV(1) RZASG100MY(1) 3 2 P 3 2 3 2 3 2 P
RZASG125MV(1) RZASG125MY(1) 4 3 2 P 4 3 2 4 3 2 4 3 2 P
RZASG140MV(1) RZASG140MY(1) 4 3 2 P 4 3 4 3 4 3 2 P

FDA-A FHA-A(9) FUA-A FAA-B FVA-A FNA-A9

INDUSTRY
MARINE
capacity class 125 35 50 60 71 100 125 140 71 100 125 71 100 71 100 125 140 35 50 60
RZASG71MV1 2 P P P P 2
RZASG100MV(1) RZASG100MY(1) 3 2 P P P P 3 2
RZASG125MV(1) RZASG125MY(1) P 4 3 2 P P P 4 3 2
RZASG140MV(1) RZASG140MY(1) 4 3 2 P 2 2 2 P 4 3
P = Pair, 2 = Twin, 3 = Triple, 4 = Double twin

CHILLERS
More details and final information
can be found by scanning or
clicking the QR codes. RZASG-MV1 RZASG-MY1 RZASG-MV RZASG-MY
FAN COIL
UNITS

Outdoor unit RZASG 71MV1 100MV(1) 125MV(1) 140MV(1) 100MY(1) 125MY(1) 140MY(1)
Dimensions Unit HeightxWidthxDepth mm 770x900x320 990x940x320
Weight Unit kg 60 70 (MY1) / 72 (MY) 78 (MV1) / 79 (MV) 70 (MY1) / 72 (MY) 78 (MV1) / 79 (MV)
Sound power level Cooling dBA 65 70 71 73 70 71 73
Heating dBA - 71(1) 73(1) - 71(1) 73(1)
AIR HANDLING

Sound pressure Cooling Nom. dBA 46 53 54 53 54


level Heating Nom. dBA 47 57
UNITS

Operation range Cooling Ambient Min.~Max. °CDB -15~46


Heating Ambient Min.~Max. °CWB -15~15.5
Refrigerant Type/GWP R-32/675
Charge kg/TCO2Eq 2.45/1.65 2.60/1.76 2.90/1.96 2.60/1.76 2.90/1.96
Piping connections Liquid/Gas OD mm 9.52/15.9
REFRIGERATION
COMMERCIAL &
TRANSPORT

Piping OU - IU Max. m 50
length System Equivalent m 70
Chargeless m 30
Additional refrigerant charge kg/m See installation manual
Level difference IU - OU Max. m 30.0
Power supply Phase/Frequency/Voltage Hz/V 1~/50 /220-240 3~/50 /380-415
Current - 50Hz Maximum fuse amps (MFA) A 20 25 32 16
CONTROL
SYSTEMS

(1)According to ENER Lot 21 | Contains fluorinated greenhouse gases

451
RZA-D

Sky Air Advance-series


Large Sky Air system for commercial applications
in the most compact casing ever

› Compact (870mm high) and lightweight single fan design makes


the unit unobtrusive, saves space and is easy to install
› Market-leading serviceability and handling, thanks to wide access
area, 7-segment display and additional handle
› Choosing for an R-32 product, reduces the environmental impact
with 68% compared to R-410A, leads directly to lower energy
consumption thanks to its high energy efficiency and has a lower
refrigerant charge
› Replace existing systems with R-32 technology without needing to
replace the piping
› Guarantees operation in heating mode down to -20°C
› Refrigerant cooled PCB guarantees reliable cooling, as it is not
influenced by ambient temperature. RZA-D
› Maximum piping length up to 100m
› Maximum installation height difference up to 30m
› Outdoor units for pair, twin, triple, double twin application
› Combines with EKLN-A low sound enclosure

Comfort cooling combination table


FCAG-B FFA-A9 FDXM-F9 FBA-A(9) FHA-A(9) FDA-A FUA-A FAA-B FVA-A FNA-A9
capacity class 50 60 71 100 125 50 60 50 60 50 60 71 100 125 50 60 71 100 125 125 200 250 71 100 125 71 100 71 100 125 50 60
RZA200D 4 3 3 2 4 3 4 3 4 3 3 2 4 3 3 2 P 3 2 3 2 3 2 4 3
RZA250D 4 2 4 4 4 2 4 2 2 P 2 2 4
P = pair application

More details and final information


can be found by scanning or
clicking the QR codes. RZA-D
Outdoor unit RZA 200D 250D
Dimensions Unit HeightxWidthxDepth mm 870x1,100x460
Weight Unit kg 117
Sound power level Cooling dBA 73 76
Heating dBA 76 79
Sound pressure Cooling Nom. dBA 53 57
level Heating Nom. dBA 60 63
Operation range Cooling Ambient Min.~Max. °CDB -20~46
Heating Ambient Min.~Max. °CWB -20~15
Refrigerant Type/GWP R-32/675
Charge kg/TCO2Eq 5/3.38
Piping connections Liquid/Gas OD mm 9.52/22.2
Piping OU - IU Max. m 100
length System Chargeless m 30
Additional refrigerant charge kg/m See installation manual
Power supply Phase/Frequency/Voltage Hz/V 3~/50 /380-415
Current - 50Hz Maximum fuse amps (MFA) A 20
Contains fluorinated greenhouse gases

452
INTRODUCTION
ARXM-R / AZAS-MV / MY

Sky Air Active-series

RESIDENTIAL
INDOOR AIR
QUALITY
Ideal solution for busy environments and small shops

› High efficiency:
- Energy labels up to A+ (cooling) / A (heating)

HEATING
- compressor offers substantial efficiency improvements
› Choosing for an R-32 product, reduces the environmental impact
with 68% compared to R-410A and leads directly to lower energy
consumption thanks to its high energy efficiency
› Very compact and easy to install
› Replace existing systems with R-32 technology without needing to

SPLIT
replace the piping

SKY AIR
› Guarantees operation in heating mode down to -15°C and in AZAS100-140MV_MY
cooling mode down to -10°C
› Refrigerant cooled PCB guarantees reliable cooling, as it is not
influenced by ambient temperature.
› Piping length up to 30m

ROOFTOP
› Exclusively offered for pair applications

VRV
AIR PURIFICATION
VENTILATION &
COMMERCIAL
Pair application
NEW NEW
FCAG-B FBA-A(9) FAA-B FHA-A(9) FVA-A ADEA-A
capacity class 71 100 125 140 71 100 125 140 71 100 125 140 71 100 125 140 71 100 125 140 71 100 125

INDUSTRY
ARXM-R P P P P

MARINE
AZAS-MV P P P P P P P P P P P P P P P
AZAS-MY P P P P P P P P P P P P P
P = pair application

CHILLERS
More details and final informa-
tion can be found by scanning
or clicking the QR codes. ARXM-R AZAS-MV AZAS-MY
FAN COIL

Outdoor Unit ARXM71R AZAS100MV AZAS125MV AZAS140MV AZAS100MY AZAS125MY AZAS140MY


UNITS

Dimensions Unit HeightxWidthxDepth mm 734x954x401 990x940x320


Weight Unit kg 49.0 72 79 72 79
Sound power level Cooling dBA - 70 71 72 70 71 72
Heating dBA - 70 71 72 70 71 72
Sound pressure Cooling Nom. dBA 52.0 53 54 55 53 54 55
AIR HANDLING

level Heating Nom. dBA 52.0 57 58 59 57 58 59


UNITS

Operation range Cooling Ambient Min.~Max. °CDB -10~46


Heating Ambient Min.~Max. °CWB -15~24 -15~15.5
Refrigerant Type/GWP R-32/675
Charge kg/TCO2Eq 1.15/0.780 2.60/1.76 2.90/1.96 2.60/1.76 2.90/1.96
Piping connections Liquid/Gas OD mm 9.52/15.9
REFRIGERATION
COMMERCIAL &

Piping OU - IU Max. m 30
TRANSPORT

length System Equivalent m - 50


Chargeless m - 30
Additional refrigerant charge kg/m 0.035 See installation manual
(for piping length exceeding 10m)

Level difference IU - OU Max. m 20.0 30.0


Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240 3~/50/380-415
Current - 50Hz Maximum fuse amps (MFA) A - 25 32 16
CONTROL
SYSTEMS

Contains fluorinated greenhouse gases

453
Options - Sky Air
FCAHG-H
FFA-A9 FDXM-F9 FBA-A(9)
FCAG-B
INDOOR UNITS
Standard panels:
BYCQ140E (white) /
BYFQ60C2W1W
BYCQ140EW (full white)(1) /
(white panel)
BYCQ140EB (black)
Decoration panel BYFQ60C2W1S
Auto cleaning panels(2)
(obligatory for cassette units, optional for others) (grey panel)
(4): BYCQ140EGF (white) /
BYFQ60B3W1
BYCQ140EGFB (black)
(standard panel)
Panels

Designer panels: BYCQ140EP


(white) / BYCQ140EPB (black)
KDBQ44B60
Panel spacer for reducing required installation height
(only for standard panel)
Sealing kit for 3- or 2-directional air discharge KDBHQ56B140 (11) BDBHQ44C60
BRYQ140B (white)
BRYQ140BB (black) BRYQ60AW (white)(9)
Sensor kit
BRYQ140C (white designer) BRYQ60AS (silver)(9)
BRYQ140CB (black designer)
Onecta app BRP069C82 (14) (18) BRP069C81 (18) BRP069C81 BRP069C81 (18)
BRC7EB530W
Individual control systems

BRC7FA532F (white) (11) (16)


for standard panel (5)(6)
BRC7FA532FB (black) (11) (16)
Infrared remote control (incl. receiver) BRC7F530W BRC4C65 BRC4C65
BRC7FB532F (designer white) (11) (16)
for white panel (5)(6)
BRC7FB532FB (designer black) (11) (16)
BRC7F530S - for silver panel (5)(6)
Madoka
BRC1H52W (9) (White) / BRC1H52S (9) (Silver) / BRC1K552K (9) (Black) User-friendly wired    
remote controller with premium design

BRC1E53A/B/C (3) (13) - Wired remote controller with full-text interface and back-light    

DIII-net connection - for connection to centralized control standard standard standard standard
Centralised

systems

DCC601A51 - intelligent Tablet Controller    


control

DCS601C51 (13) - intelligent Touch Controller    


DCS302C51 (13) - Central remote controller    
DCS301B51 (13) - Unified ON/OFF controller    
EKMBPP1 - Modbus interface for monitoring and control    
for individual

RTD-10 - Modbus interface for infrastructure cooling    


Building Management System &

control
Standard protocol interfaces

RTD-20 - Modbus interface for retail    


RTD-HO - Modbus interface for hotel    
KLIC-DI_V2 - KNX Interface    
DCM601B51 - intelligent Touch Manager    
for central control

DGE601A51 - Edge adapter for connection to Daikin Cloud Plus    


DGE602A51 - Edge lite adapter for connection to Daikin Cloud Plus    
EKMBDXB - Modbus interface    
DCM010A51 - Daikin PMS interface    
DMS502A51 - BACnet Interface    
DMS504B51 - LonWorks Interface    
BAE20A62 (25 - 35)
Auto cleaning filter see deco panel
BAE20A102 (50 - 60)
UV Streamer kit (purifies the air of pollutants such as virusses, UV Streamer kit BAEF125AWB (22)
bacteria, fine dust, odours, allergens, etc ensuring a healthy
Replacement filter BAF55A125
indoor environment)
ePM10 60%
BAF552AA160 (23)
Filters

(BAF552AA160-5:
High efficiency filter
box of 5 filters)
(BAF552AA160-10:
box of 10 filters)

Replacement long-life filter, non-woven type KAF5511D160 KAF441C60

Filter chamber
Extension wire auto cleaning panel
Wiring and
sensors

(required when auto cleaning panel AND Onecta app are both installed)
KRCS - External wired temperature sensor KRCS01-5B KRCS01-4 KRCS01-4 KRCS01-4
SB.K.RSS_RFC
K.RSS - External wireless temperature sensor  
(EKEWTSC-2 + K.RSS)
Wiring adapter with 2 output signals
KRP1BA58 (10)(11) KRP1B57 (10) KRP1B56 (10)
(compressor/ Error, Fan output)
Wiring and sensors Adapters

Adapter (interlock for fresh air intake fan) KRP1B54


Adapter with 4 output signals
EKRP1C12 (10)(11) EKRP1B2 EKRP1B2 (7)
(compressor / Error, Fan, Aux, heater, Humidifier output)
Adapter for centralised external monitoring/control
KRP2A53 (10) KRP2A51 (7)(10)
(controls 1 entire DIII-NET system)
Adapter for centralised external monitoring/control via dry contacts and setpoint
KRP4A53 (10)(11)(17) KRP4A51 KRP4A54-9 KRP4A52 (10)
control via 0-140Ω (for dedicated indoor)
Adapter for keycard and/or window contact connection
BRP7A53 BRP7A53 BRP7A54 (10) BRP7A51 (12)
(in combination with BRC1H*, BRC1/2/3E* only)
Installation box/Mounting plate for adapter PCBs (when there is no space in the
KRP1H98A (11) KRP4A93 KRP1BC101 KRP1BC101
switchbox, an installation box is required)
Wiring kit for Remote ON/OFF or Forced OFF standard standard standard standard
Drain pump kit
Multi zoning kit
 
(for detailed model code overview refer to multizoning argue card in this catalogue)
Others

L-type piping kit (upward direction)

KDDP55C160-1 (chamber)
Fresh air intake kit (direct installation type) KDDQ44XA60
KDDP55D160-2 (diffuser) (11)
KDAP25A56A (35-50)
Air discharge adapter for round duct KDAP25A71A (60-71)
KDAP25A140A (100-140)
(1) Dirt formation is more easily visible on white insulation. It is recommended not to install this (4) T he option is intended exclusively for use in fine dust enviornments (e.g. Clothing shops).
option in environments with a high concentration of dirt. Do not use it in environments that are greasy or have high humidity. F = finer mesh
(2) To be able to control option BYCQ140EG(F)/EGFB, controller BRC1H*, BRC1E* is needed. These (5) Sensing function is not available
options cannot be combined with RXYSQ*, multi or non-inverter split units (6) Individual flap control function not available
(3) Included languages are: (7) If installing an electrical heater, an option PCB for external electrical heater (EKRP1B2) for
A: English, German, French, Dutch, Spanish, Italian and Portuguese each indoor unit is required. These options require mounting plate KRP4A96. Electrical
B: English, Bulgarian, Croatian, Czech, Hungarian, Romanian and Slovenian heaters and humidifiers are field-supplied. Do not install them inside the equipment.
C: English, Greek, Polish, Russian, Albanian, Slovak and Turkish (8) Mounting plate KRP4A96 is required for these options. Maximum 2 option PCB’s can be
mounted.
(9) This option cannot be used with RR and RQ models
454
INTRODUCTION
FDA125A FDA200-250A ADEA-A FAA-B FTXM-R FHA-A(9) FUA-A FVA-A FNA-A9

RESIDENTIAL
INDOOR AIR
QUALITY
BYBS125D (19) KDBTP49B140

HEATING
KDBHP49B140

BRP069C81 (18) BRP069C82 (20) BRP069C81 (18) BRP069C81 (18) Integrated in PCB BRP069C81 (18) BRP069C81 (18) BRP069C81 (18) BRP069C81 (18)

BRC7EA631 (71 class)

SPLIT
BRC4C65 BRC4C65 BRC4C65 ARC466A67 BRC7GA53-9 BRC7C58 BRC4C65
BRC7EA632 (100 class)

       

 (BRC073A1)
BRCW901A03/A08
       

SKY AIR
extention cords
available (15)
standard standard standard standard KRP928BB2S (15) standard standard standard standard
       
     (15)    
     (15)    
     (15)    
     (15)    

ROOFTOP
     (15)    
     (15)    
     (15)    
     (KLIC-DDV3) (15)    
     (15)    
     (15)    
     (15)    
     (15)    
     (15)    

VRV
     (15)    
     (15)    

AIR PURIFICATION
VENTILATION &
COMMERCIAL
KAF501B56 (35-50)
BAFL502A250 (20) KAF501B80 (60-71) KAF5511D160 KAFJ95L160

INDUSTRY
KAF501B160 (100-140)

MARINE
BDD500B250

KRCS01-4 KRCS01-6B KRCS01-4 KRCS01-4 KRCS01-4 KRCS01-4 KRCS01-4


SB.K.RSS_FDA
    
(EKEWTSC-1 + K.RSS)
KRP4A51 (17) KRP4A51 (10) KRP413AB1S (15) KRP1B57 (10)

CHILLERS
KRP1C64 (8) KRP1C65 KRP1B54 KRP1B54 (10)
EKRP1B2 (7) EKRP1C13 EKRP1B2 (7) KRP1B56

KRP2A51 (8) KRP2A51 (17) KRP2A51 (7)(10)

KRP4A52 (10) KRP4A52 (10) KRP1B97 KRP4A52 (10) KRP4A54-9


FAN COIL

BRP7A54 (8) BRP7A54 BRP7A51 (12) BRP7A51 (10) BRP7A52 (10) BRP7A53 (10) BRP7A52 (10)
UNITS

KRP4A96 KRP1BC101 KRP4B93 KRP1D93A (21) KRP1BA97 KRP4AA95 KRP1BB101


EKRORO3 standard standard EKRORO4 EKRORO5 standard standard
KDU50R63 (35 - 60)
BDU510B250VM K-KDU572KVE
KDU50R160 (71 - 140)

AIR HANDLING

KHFP5MA35 (35)
UNITS

KHFP5N63 (50-60)
KHFP5N160 (71-140)

KDAP25A56A (35-50)
KDAJ25K140A KDAP25A71A (60-71)
REFRIGERATION
COMMERCIAL &

KDAP25A140A (100-140)
TRANSPORT

(10) Requires installation box for adapter PCB, refer to table for model code (19) For directly mounting the decoration panel on the unit, decoration panel option EKBYBSD is
(11) This option cannot be combined with BYCQ140EG(F)/EGFB required.
(12) Maximum 2 optional PCBs can be mounted (20) This option cannot be combined with KRP4A51 and KRP2A51. (in case of filter, filter chamber
(13) Applicable boxes (KJB*) to mount controllers can be found in the controls option list is required)
(14) Extention wire (EWHAR1) is needed if both auto cleaning panel AND Onecta app are connected (21) Mounting plate KKSAP50A56 needed for 35-50 capacity class
(15) Wire harness EKRS21 needed. Standard Wireless LAN needs to be turned off to use these (22) Only possible in combination with BYCQ140E and BYCQ140EW. Cannot be combined with
controllers other filters, chambers, fresh air intake kits or air discharge outlet sealing member kit
(16) The active airflow circulation function is not available for this controller (23) Only possible in combination with BYCQ140E/EW/EB. Cannot be combined with other filters,
CONTROL
SYSTEMS

(17) This option cannot be combined with Onecta app chambers, fresh air intake kits or discharge outlet sealing member kit
(18) Only possible in combination with wired or wireless remote control
455
Options - Sky Air

R-32
RZAG-A RZAG-NV1/NY1 RZASG-MV(1)/MY(1) RZA-D AZAS-MV/MY
KHRQ22M20TA
for twin KHRQ58T (imperial size) KHRQ58T (imperial size)
(imperial size)
Refrigerant branch

KHRQ58H (100 - 140) KHRQ250H7


piping (3)

for triple KHRQ58H (imperial size)


(imperial size) (imperial size)
KHRQ58T (3x) (125 - 140) KHRQ58T (3x) (125 - 140) KHRQ22M20TA (x3)
for double twin
(imperial size) (imperial size) (imperial size)
Asymmetric combinations ASYCPIR (see table
piping reducer below)

Demand adapter kit SB.KRP58M52 (1) SB.KRP58M52 (1) KRP58M51 (2)

Bottom plate heater - To keep drain


holes ice-free in extreme weather EKBPH140N EKBPH250D
conditions

Sound enclosure EKLN140A EKLN140A

(1) Contains KRP58M1 and obligatory mounting kit EKMKSA2


(2) To mount KRP58M51, an additional mounting kit (EKMKSA3) needs to be used (obligatory)
(3) For metric size refrigerant branching contact your local sales representative

EKLN140A - Sound enclosure

Drain pan EKLN140-DP


Drain pan heater tape EKLN140-DPHT (1)
(1) Only in combination with EKLN140-DP

Option for asymmetric combination (Asymmetric combinations piping reducer)

Liquid GAS
ASYCPIR
ø 9.52  ø 6.4 ø 12.7  ø 9.52 ø 15.9  ø 12.7
FDXM50F9 
FFA50A9 
FBA50A9 
RZAG35A FCAG50B 
FNA50A9 
FTXM50R 
FHA50A9 
FBA71A9 
FCAG71B  
RZAG60A
FTXM71R 
FHA71A9  

Example of using:
1) Connecting a pipe of ø12.7 to a gas pipe connection port for ø15.9:

No.1 Inter-unit piping


Be sure to attach
the gasket. No. 3 (flare nut (for ø15.9))
No. 2
Connection port

456

You might also like