Engineering Change Notice Format
Engineering Change Notice Format
An assessment of the impact to the existing revision and systems that currently conform to
the USB specification:
8 Type-C to Type-C cables from 7 different companies were used in the assessment. None of 8 cables passed the
requirements in the existing revision of the specification.
Checked with the change, 6 out of 8 cables met IMR requirement and 6 out of 8 cables meet IRL requirement.
Actual Change
To:
where fmax = 12.5 GHz and Vin(f) is the input trapezoidal pulse spectrum, defined in Figure 3-44.
To:
𝐼𝐼𝐼𝐼𝐼𝐼 ≤ 0.126 ∙ 𝐼𝐼𝐼𝐼𝐼𝐼𝐼𝐼𝐼𝐼𝐼𝐼𝐼𝐼𝐼𝐼𝑞𝑞 2 + 3.024 ∙ 𝐼𝐼𝐼𝐼𝐼𝐼𝐼𝐼𝐼𝐼𝐼𝐼𝐼𝐼𝐼𝐼𝐼𝐼 − 23.392
-34
-36
-38
IMR Limit, dB
-40 Fail
-42
-44
Pass
-46
-48
-12 -11 -10 -9 -8 -7 -6 -5 -4 -3 -2
ILfitatNq, dB
To Figure 3-45
From:
𝐼𝐼𝐼𝐼𝐼𝐼 ≤ 0.046 ∙ 𝐼𝐼𝐼𝐼𝐼𝐼𝐼𝐼𝐼𝐼𝐼𝐼𝐼𝐼𝐼𝐼𝑞𝑞 2 + 1.812 ∙ 𝐼𝐼𝐼𝐼𝐼𝐼𝐼𝐼𝐼𝐼𝐼𝐼𝐼𝐼𝐼𝐼𝐼𝐼 − 15.825
To:
𝐼𝐼𝐼𝐼𝐼𝐼 ≤ 0.046 ∙ 𝐼𝐼𝐼𝐼𝐼𝐼𝐼𝐼𝐼𝐼𝐼𝐼𝐼𝐼𝐼𝐼𝑞𝑞 2 + 1.812 ∙ 𝐼𝐼𝐼𝐼𝐼𝐼𝐼𝐼𝐼𝐼𝐼𝐼𝐼𝐼𝐼𝐼𝐼𝐼 − 10.784
-18
-20
-22
Fail
IRL Limit, dB
-24
-26
Pass
-28
-30
-32
-12 -11 -10 -9 -8 -7 -6 -5 -4 -3 -2
ILfitatNq, dB
To Figure 3-46
To:
` ≤ 0.126 ∙ 𝐼𝐼𝐼𝐼𝐼𝐼𝐼𝐼𝐼𝐼𝐼𝐼𝐼𝐼𝐼𝐼𝑞𝑞 2 + 3.024 ∙ 𝐼𝐼𝐼𝐼𝐼𝐼𝐼𝐼𝐼𝐼𝐼𝐼𝐼𝐼𝐼𝐼𝐼𝐼 − 21.392
To:
≤ 0.046 ∙ 𝐼𝐼𝐼𝐼𝐼𝐼𝐼𝐼𝐼𝐼𝐼𝐼𝐼𝐼𝐼𝐼𝑞𝑞 2 + 1.812 ∙ 𝐼𝐼𝐼𝐼𝐼𝐼𝐼𝐼𝐼𝐼𝐼𝐼𝐼𝐼𝐼𝐼𝐼𝐼 − 9.784
See Figure 3-53