Datablad Ex-Ventiler HA4047

Download as pdf or txt
Download as pdf or txt
You are on page 1of 6

Solenoid - Operated Directional HA 4047

Control Valves HD3-EX 6/2008

Size 06 · pmax up to 250 bar · Qmax up to 32 L/min

q 4/3-, 4/2- way directional control valves

q - proof ATEX solenoids class II 2 G


(optional D) EEx d IIC T5

q Solenoids can be turned around their axis


to any position

q Four-land spool - reduced functional de-


pendence
on fluid viscosity

q Push button manual override

q Installation dimensions to DIN 24 340 /


ISO 4401 / CETOP RP121-H

q Subplates see data sheet HA 0002

Functional Description

The HD3-EX directional control valves consist of housing The operating solenoids are DC solenoids. The coil (6, 7)
(1), a control spool (5) with two centering springs (4) and can be rotated by 90°. By loosening the nut (8), the
cylindrical operating solenoids (2, 3).The valve can be solenoids can be turned or replaced without interfering
operated in explosive environment. with any seals of the valve.
The three-position directional control valves are fitted In the case of solenoid malfunction or power failure, the
with two solenoids and two springs. Two-position spool of the valve can be shifted by manual override (9),
directional control valves have either one solenoid and provided the pressure in T-port does not exceed 25 bar.
one return spring or two solenoids and a detent The basic surface treatment of the valve housing (1) is
assembly. phosphate coated and the solenoids (2, 3) are zinc
coated.

8 2 6 7 3 8
4 1 5 4

A B

1
HA 4047
Ordering Code

HD3 - EX - - / 20

design number (progressive) of the


valves
4-way
Directional Valve Cetop 03

elektric voltage and solenoid coils


012C coil(s) for V12DC
024C coil(s) for V24DC
115A coil(s) for V110/50-V115/60 AC
230A coil(s) for V220/50-V230/60 AC
see also electric characteristics (6)
electrically controlled, Ex-prof solenoid

code reserved for options and variants


omit protection to gas according to
CE 0722 Ex II 2 G EExd II C T5
D protection to dust according to
Functional symbols CE 0722 Ex II 2 D EExd II C T5
see the table Functional symbols S-** calibrated orifice on P port

Technical Data

Nominal size mm 06
Maximum flow L/min 32
Max. operating pressure at porte P, A, B, T bar 250
Pressure drop bar see Dp-Q characteristics
Hydraulic fluid Hydraulic oils of power classes (HL, HLP) to DIN 51524
Fluid temperature range for NBR °C -30 ... +80
Ambient temperature, max. °C +50
Viscosity range cSt 20 ... 400
Maximum degree of fluid contamination Class 21/18/15 to ISO 4406 (1999)
Max. allowable voltage variation % AC / DC : ±10
Max. switching frequency 1/h 15 000
Enclosure type to EN 60 529 IP 67
Duty cycle % 100
7
Service life cycles 10
Weigt - valve with 1 solenoid 2,6
kg
- valve with 2 solenoids 3,7
Mounting position optional

2
HA 4047
Functional Symbols
Designation Symbol Interposition Designation Symbol Interposition

1C 1ML

4C 0ML

0C 1MLb

3C 1LLb

1LL 4MLb

3ML 0MLb

4ML 3MLb

Dp-Q Characteristics Measured at n = 32 mm /s


2

Pressure drop Dp related to flow rate.

P ® A/B, A/B ® T P-A P-B A-T B-T P-T


1C 2 2 2 2 -
4C 4 4 4 4 2
Pressure drop Dp [bar]

0C 2 2 3 3 2
3C 2 2 3 3
1LL 3 3 4 4 -
1LLb 3 3 4 4 -
1ML - 2 2 - -
4ML 4 - - 4 2
0ML 2 - - 3 2
3ML 2 - - 2 -

Flow Q [L/min]

VERSION "S" - Orifice in P-Port

Type ÆD (mm) Dimensions Description

P-Port orifices limit the flow into the directional


3S-10 1.0
control valve.

Attention:
3S-20 2,0
When the orifice in P port is additionally
mounted the standard used square ring NBR
is replaced with O-ring from Viton.
3S-25 2.5 Seal ring

3
HA 4047
Valve Dimensions Dimensions in millimetres

5 12,5 40,5
33
21,5
12,7
31

32,5
45,5
25,7
15,5
7

5,1

85 7 68
302

1 Solenoid a
2 Solenoid b
3 Name plate
6 61,5 6 4 Square ring (4 pcs.)
9,25 x 1,68 supplied with valve
5 4 mounting holes
6 Electrical connector,
3 EN 1745301-803
8 Space required to remove connector
Æ9,5
43,5
Æ45

37,3
49,3
24
Æ5,3
1,4

Æ8
8 1 Æ12,4 4 2 8

Required surface finish of


interface

EXPLOSION PROOF SOLENOIDS TYPE GMA-6/* SERIES 271


II 2 G (optional D) EEx d IIC T5
1 FOR HYDRAULIC VALVES ATEX
5

4
3
85

1 manual override operation is by pushing the


61,5

extended pin
2 2 normalised cable gland - fixing torque 8Nm ±1 device
has threaded attachment 1/2" concial -ISO 7/1
3 earth connection screw
4 threaded plug (socket HEX 1,5) to lock the
retainingnut 5
5 nut for retaining the coil - fixing torque 6 Nm ±1
Æ45 outside HEX 24

50 43,5

4
HA 4047
EXPLOSION PROOF SOLENOIDS TYPE GMA-6/* SERIES 271

- On/off pushing solenoids type GMA-6/*series 271

- Ex-proof solenids according to ATEX 94/9/CE

- Code & protection class CE 0722 Ex II 2 G EExd II C T5 for gas, optional CE 0722 Ex II 2 D EExd II C T5 for dust.

- Sealed and tight execution, protection IP 67 according to IEC 144

- Surface protection of solenoid : nickel coating, thickness 7 micron min.

- Electric connection : solenoids are supplied with 3-wire cable, with section of 1,5 mm2 , standard length of 1,5 m, already
connected to coil.
Earth connections are to be made :
Ÿ internally, by the green-yellow wire of the cable
2
Ÿ externally, by a wire of minimum section of 4 mm fastened to the earth screw

Electric connection must be in accordance with EX-proof norm ATEX.

- Coil is secured to tube by screwing the nut - torque 6 Nm ± 1 - across the coil.
Nut must be then locked by the plug present on it.

Conformity of unit to the norms is not granted if coil is used separately from its electromagnetic tube.

- Types : GMA-6/EV for screw-in valves, ON/OFF


GMA-6/HD for Cetop 03 valves, ON/OFF
GMA-6/PX for Cetop 03 valves, proportional
GMA-6/*-D for dust ( CE 0722 Ex II 2 D EExd C T5 )

- Max. dynamic pressure : up to 350 bar

Coils are designed for Dc supply and they are available for voltages from 12 to 250 VDC, for Ac supply coils are designed
with built-in bridge rectifier, they are available for supply voltages from 24 to 250 VAC.
Coils are supplied with 3-wire cable with sylicon-rubber protective covering.
2
Wires have section 1,5 mm - earth connection cable is green-yellow.
Electric connections must be realized according to the relevant ex-proof norms according to ATEX.
Electric power consumption with warm coil:
EExd IIC T5. - max. 11 W
Ambient temperatute : from -20 ...+40 °C

Labelling: solenoid label indicates supply voltage, protection class EExd, certification number by CESI
(INERIS) and maximum absorbed power.

Note: copy of certiticate is available on request: CESI 03 ATEX 212. (for GMA6-6/*)
INERIS O5ATEX0028X (for GMA6-6/D)

5
HA 4047
Spare Parts

Solenoid retaining nut with seal


Orifice in P port
Type ÆD (mm) Seal ring Ordering number
3S-10 1.0 484-9973
3S-20 2.0 9.25 x 1.75 484-9975
3S-25 2.5 484-9976

Seal kit
Type Dimensions, number Ordering number
Standard - NBR70 9.25 x 1.68 (4 pcs.) 17 x 1.8 (2 pcs.) 484-9961
Viton 9.25 x 1.78 (4 pcs.) 17.17 x 1.78 (2 pcs.) 484-9971
Mounting bolts
Dimensions, number Tightening torque Ordering number
M5 x 45 DIN 912-10.9 (4 pcs.) 8.9 Nm 484-9958

Caution!
Ÿ For applications outside the given parameters, please consult us.
Ÿ For directional control valves with two solenoids, one solenoids must be without power before the other solenoid
can be powered charged. Switching time for directional valves with detent assembly (impulse control) should not be
shorter than 60 ms. With directional valves with cushioned spool shifting, the switching time must correspond
with the shifting time.
Ÿ Other for spool symbols on request.
Ÿ The packing foil is recyclable.
Ÿ Mounting bolts or studs must be ordered separately.
Ÿ The technical information regarding the product presented in this catalogue is for descriptive purposes only. It should
not be construed in any case as a guaranteed representation of the product properties in the sense of the law.

ARGO-HYTOS s.r.o. CZ - 543 15 Vrchlabí


Tel.: +420-499-403111, Fax: +420-499-403421
E-mail: [email protected]
www.argo-hytos.com

6 Subject to alteration without notice!