Ly01-Plan View

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

300

2350

1750
CONCRETE PAD +400
FROM ROAD LEVEL

300
ASPHALT -380

F G H
LY02 LY02 LY02

D E
LY02 LY02 WALKWAY - 200

L L

625
625
LY02 LY02
exhaust air

outside air UTA. E.P.


dim. 1600 x 2180H x 600mm

625
625
From REB

Cooling-2150A
supply air

1400
F.F. ± 0.00

625
625

return air
GAMMA P300mm
or similar ( By Delta )
I

625
by-pass
625
1010

2 MOTOR FAN 37 KW -IE3 LY02


WIRE from REB

1690
GAMMA P200mm 1 MOTOR FAN 37 KW -IE3
from REB WIRE from REB
UTA. E.P.
dim. 1600 x 2180H x 600mm
+tubular 120
From REB

GAMMA P150mm

1300
or similar ( By Delta)
C C
LY02 LY02

GAMMA P300mm
or similar ( By Delta )

1500
1000
NEW INSULATION DUCT
500 x 500mm ELECTRIC
FOR EXHAUST B B PANEL WITH INVERTER
FROM REB 800 x 980H x 360P
LY02 LY02
hb = 1000 mm ( da def. con cliente )
Wire for motor from REB

Return air
1400 x 450Hmm
1400

20.700 m³\h
V=9.13 ms

BUS DUTCT F.M.


100AMP.
SUGGEST WIRE ..........mm²

BUS DUTC light


Bus duct 25 AMP.
level from floor 3400 SUGGEST WIRE ..........mm²

NEW REDUCTION FLAT ON SIDE LIGHT


FROM 1200 x 400 Hmm to mod......Lumen7200-60W
800 x 400Hmm 0.3 AMP. EACH.

A A
LY02 LY02

Textile duct Ø 700 Return air


6.600 m³\h 1200 x 450Hmm
Halfmoon V = 9.6 ms 16.100 m³\h - V=8.30 ms

NEW INSULATION DUCT


Textile duct Ø 700
500 x 500mm
FOR EXHAUST 6.600 m³\h
FROM REB Halfmoon V = 9.6 ms

1322

Return air
1000 x 450Hmm
11.500 m³\h - V=7.11 ms

NEW INSULATION DUCT


500 x 500mm
FOR EXHAUST
FROM REB

Return air
EXISTING FAN 500 x 450Hmm
rotate 4600m³\h - V=5.69 ms

PLAN VIEW Sc. 1 : 50

04 30 NOVEMBER 2017 NEW LAYOUT FOR SANTONI 40 MC. A.TURCHI A.TURCHI S. ROSSETTO
03 20 NOVEMBER 2017 UPDATE POSITION CHILLER A.TURCHI A.TURCHI S. ROSSETTO
02 25 OCTOBER 2017 PROPOSED FOR CHECK ON SITE A.TURCHI S. ROSSETTO S. ROSSETTO
01 12 JULY 2017 UPDATED SOLUTION ,WITH MR. S.R. ON SITE A.TURCHI S. ROSSETTO S. ROSSETTO
00 08 JULY 2017 EMESSO PER APPROVAZIONE A.TURCHI S. ROSSETTO S. ROSSETTO
REV. DATA \ DATE DESCRIZIONE \ DESCRIPTION PREPARED CHECKED APPROVED

ARCHIVIO \ ARCHIVE
SCALE PLOT STYLE NOTE AGGIUNTIVE
Scala
ReB _STR STANDARD.ctb ADDITION NOTE
1 : 50 xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
FILE LAYOUT PAPER
Carta A0
UNI EN ISO 5457
RESPONSABILE DI CANTIERE
COSTRUCTION MANAGER
40 Santoni - revisione finale LY01 1189x841 xxxxxxxxxxxxxxxxx

COMMITTENTE \ COSTUMER
NOME INDIRIZZO DESCRIZIONE PROGETTO
NAME ADDRESS DESCRIPTION PROJECT

DELTA VIETNAM PLAN VIEW


( GALIL ) FOR PRELIMINARY
RESPONSABILE DI COMMESSA
TAVOLA \ DRAW.
PROJECT MANAGER
NEW PROPOSED DRAWING LY 001
STEFANO ROSSETTO
FOR EQUIPMENTS FOR 40 SANTONI DATA \ DATE
06- 07 - 2017

ReB IMPIANTI
46042 Castel Goffredo (Italy) COMMESSA / JOB
VIia Contrada Molino 17/N
Tel. +39-0376.17.15.753
Fax. +39-0376.77.91.03
Mail : [email protected]
17 - 4910
Web: www.reb-impianti.it

N.B. This document and all information there on are the exclusive property of ReB IMPIANTI and must not be copied and reproduced for any purpose
other than that the document is provided without written authorization of ReB IMPIANTI
N.B. Questo documento e tutte le informazioni contenute sono di esclusiva proprietà di R. e B. Impianti. E' vietata la riproduzione e la copia senza
preventiva autorizzazione di R. e B. Impianti
\\serverr3\Archivi\Ufficio Tecnico su REB 2\02 Lav Aperti Estero\Delta Vietnam\17-4910 sala santoni 40 mc\03 Disegni COPYRIGHT BY ReB IMPIANTI