Ly01-Plan View
Ly01-Plan View
Ly01-Plan View
2350
1750
CONCRETE PAD +400
FROM ROAD LEVEL
300
ASPHALT -380
F G H
LY02 LY02 LY02
D E
LY02 LY02 WALKWAY - 200
L L
625
625
LY02 LY02
exhaust air
625
625
From REB
Cooling-2150A
supply air
1400
F.F. ± 0.00
625
625
return air
GAMMA P300mm
or similar ( By Delta )
I
625
by-pass
625
1010
1690
GAMMA P200mm 1 MOTOR FAN 37 KW -IE3
from REB WIRE from REB
UTA. E.P.
dim. 1600 x 2180H x 600mm
+tubular 120
From REB
GAMMA P150mm
1300
or similar ( By Delta)
C C
LY02 LY02
GAMMA P300mm
or similar ( By Delta )
1500
1000
NEW INSULATION DUCT
500 x 500mm ELECTRIC
FOR EXHAUST B B PANEL WITH INVERTER
FROM REB 800 x 980H x 360P
LY02 LY02
hb = 1000 mm ( da def. con cliente )
Wire for motor from REB
Return air
1400 x 450Hmm
1400
20.700 m³\h
V=9.13 ms
A A
LY02 LY02
1322
Return air
1000 x 450Hmm
11.500 m³\h - V=7.11 ms
Return air
EXISTING FAN 500 x 450Hmm
rotate 4600m³\h - V=5.69 ms
04 30 NOVEMBER 2017 NEW LAYOUT FOR SANTONI 40 MC. A.TURCHI A.TURCHI S. ROSSETTO
03 20 NOVEMBER 2017 UPDATE POSITION CHILLER A.TURCHI A.TURCHI S. ROSSETTO
02 25 OCTOBER 2017 PROPOSED FOR CHECK ON SITE A.TURCHI S. ROSSETTO S. ROSSETTO
01 12 JULY 2017 UPDATED SOLUTION ,WITH MR. S.R. ON SITE A.TURCHI S. ROSSETTO S. ROSSETTO
00 08 JULY 2017 EMESSO PER APPROVAZIONE A.TURCHI S. ROSSETTO S. ROSSETTO
REV. DATA \ DATE DESCRIZIONE \ DESCRIPTION PREPARED CHECKED APPROVED
ARCHIVIO \ ARCHIVE
SCALE PLOT STYLE NOTE AGGIUNTIVE
Scala
ReB _STR STANDARD.ctb ADDITION NOTE
1 : 50 xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
FILE LAYOUT PAPER
Carta A0
UNI EN ISO 5457
RESPONSABILE DI CANTIERE
COSTRUCTION MANAGER
40 Santoni - revisione finale LY01 1189x841 xxxxxxxxxxxxxxxxx
COMMITTENTE \ COSTUMER
NOME INDIRIZZO DESCRIZIONE PROGETTO
NAME ADDRESS DESCRIPTION PROJECT
ReB IMPIANTI
46042 Castel Goffredo (Italy) COMMESSA / JOB
VIia Contrada Molino 17/N
Tel. +39-0376.17.15.753
Fax. +39-0376.77.91.03
Mail : [email protected]
17 - 4910
Web: www.reb-impianti.it
N.B. This document and all information there on are the exclusive property of ReB IMPIANTI and must not be copied and reproduced for any purpose
other than that the document is provided without written authorization of ReB IMPIANTI
N.B. Questo documento e tutte le informazioni contenute sono di esclusiva proprietà di R. e B. Impianti. E' vietata la riproduzione e la copia senza
preventiva autorizzazione di R. e B. Impianti
\\serverr3\Archivi\Ufficio Tecnico su REB 2\02 Lav Aperti Estero\Delta Vietnam\17-4910 sala santoni 40 mc\03 Disegni COPYRIGHT BY ReB IMPIANTI