DB2170960EN

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

2170960 DATA SHEET

Valid from:
01.05.2018
ETHERLINE® LAN 500 Cat.6A S/FTP

Description
®
ETHERLINE LAN 500 Cat.6A S/FTP is an installation cable for
structured horizontal cabling. These cables are ideal for LAN data
transmission in all Ethernet (IEEE 802.3) applications up to 10GBase-T
and higher. The copper braid overall screen offers protection against
electromagnetic interference as well as mechanical reinforcement.
IEC 61156-5/ISO/IEC 11801, EN 50173-1, EIA/TIA 568C.2

General characteristics

Conductor Solid bare copper wire, AWG 23/1


Insulation solid polyethylene
Core identification code Pair 1: white – blue Pair 2: white – orange
Pair 3: white – green Pair 4: white - brown
Stranding two cores stranded to pairs,

Pair screening aluminum laminated polyester foil


Stranding Pairs stranded to bundle

Screening Braiding of tinned copper wires


Outer sheath PVC compound
outer Ø: approx. 7.3 mm
color: grey, similar to RAL 7035

Mechanical characteristics

Minimum bending radius at installation: 4 x cable Ø


fixed installation: 8 x cable Ø
Permissible temperature range at installation: 0 ˚C up to +50 ˚C
fixed installation: -20 ˚C up to +60 ˚C
Flame propagation flame retardant acc. to IEC 60332-1-2
Classification of fire behaviour Eca
acc. to EU Regulation 305/2011 (CPR) (acc. to EN13501-6 and EN50575)

Creator: TOST/PDC Document: DB2170960EN


Page 1 of 2
Released: HAPF/PDC Version: 01
We reserve all rights according to DIN ISO 16016.
PD 0019/05_04.18EN
2170960 DATA SHEET
Valid from:
01.05.2018
ETHERLINE® LAN 500 Cat.6A S/FTP

Electrical characteristics
DC-Resistance (loop) max. 150.0 Ω/km
Insulation resistance min. 5 GΩ x km
Mutual capacitance nom. 43 nF/km at 1 kHz
Characteristic impedance nom. 100 Ω acc. to IEC 61156-5
Operating peak voltage 100 V (not for power purposes)
velocity of propagation approx. 0.79 c
Test voltage core/core: 1000 V

Transmission properties
Transmission properties acc. to IEC 61156-5 for Category Cat.6A:
Attenuation PS NEXT EL FEXT Return Loss
f
[dB/100m] [dB] [dB] [dB]
[MHz]
standard typical standard typical standard typical standard typical
1* 2.1 1.8 75 100 68 105 20.0 -
4 3.8 3.4 66 100 56 105 23.0 27
10 6.0 5.4 60 100 48 97 25.0 30
16 7.6 6.8 57 100 44 93 25.0 30
31,25 10.7 9.6 53 100 38 87 23.6 30
62,5 15.5 13.7 48 100 32 81 21.5 30
100 19.9 17.4 45 100 28 77 20.1 30
200 29.1 25.0 41 92 22 71 18.0 25
250 33.0 28.1 39 90 20 69 17.3 24
300 36.4 32.1 37 89 18 67 16.8 23
500 48.9 46.6 34 86 14 65 15.2 23

* Extract of normative minimum requirements

Standard
EU-Directive Dangerous and forbidden substances acc. to RoHS
directive (2011/65/EU) are not allowed to the
manufacturing.

Creator: TOST/PDC Document: DB2170960EN


Page 2 of 2
Released: HAPF/PDC Version: 01
We reserve all rights according to DIN ISO 16016.