Safety notices . . . . . . . . . . . vii Chapter 24. (266F) Reference codes 177
Chapter 1. System reference codes Chapter 25. (2689) Reference codes 179
(1xxx - Axxx) overview . . . . . . . . 1
Block replacement of FRUs . . . . . . . . . 1 Chapter 26. (2742) Reference codes 185
Chapter 2. (1000) Reference codes . . . 3 Chapter 27. (2743) Reference codes 187
Chapter 3. (1100) Reference codes . . . 23 Chapter 28. (2744) Reference codes 189
Chapter 4. (1400) Reference codes . . . 45 Chapter 29. (2745) Reference codes 191
Chapter 5. (1401) Reference codes . . . 69 Chapter 30. (2746) Reference codes 193
Chapter 6. (169C) Reference codes 117 Chapter 31. (2749) Reference codes 195
Chapter 7. (1750) Reference codes 121 Chapter 32. (2757) Reference codes 207
Chapter 8. (198B) Reference codes 123 Chapter 33. (2760) Reference codes 215
Chapter 9. (198C) Reference codes 127 Chapter 34. (2763) Reference codes 217
Chapter 10. (198D) Reference codes 131 Chapter 35. (2767) Reference codes 225
Chapter 11. (198E) Reference codes 135 Chapter 36. (2768) Reference codes 237
Chapter 12. (19A1) Reference codes 139 Chapter 37. (2771) Reference codes 249
Chapter 13. (19A3) Reference codes 143 Chapter 38. (2772) Reference codes 251
Chapter 14. (19B0) Reference codes 147 Chapter 39. (2780) Reference codes 253
Chapter 15. (19B1) Reference codes 151 Chapter 40. (2782) Reference codes 261
Chapter 16. (19B3) Reference codes 155 Chapter 41. (2787) Reference codes 269
Chapter 17. (19B5) Reference codes 159 Chapter 42. (2793) Reference codes 271
Chapter 18. (19B7) Reference codes 163 Chapter 43. (2805) Reference codes 273
Chapter 19. (2058) Reference codes 167 Chapter 44. (280D) Reference codes 275
Chapter 20. (2105) Reference codes 169 Chapter 45. (280E) Reference codes 277
Chapter 21. (2107) Reference codes 171 Chapter 46. (2838) Reference codes 279
Chapter 22. (266D) Reference codes 173 Chapter 47. (283C) Reference codes 281
Chapter 23. (266E) Reference codes 175 Chapter 48. (283D) Reference codes 283
Chapter 50. (2843) Reference codes 297 Chapter 77. (4320) Reference codes 443
Chapter 51. (2844) Reference codes 309 Chapter 78. (4322) Reference codes 447
Chapter 52. (2847) Reference codes 321 Chapter 79. (4323) Reference codes 451
Chapter 53. (2849) Reference codes 325 Chapter 80. (4325) Reference codes 455
Chapter 54. (284B) Reference codes 327 Chapter 81. (4326) Reference codes 459
Chapter 55. (2875) Reference codes 339 Chapter 82. (4327) Reference codes 463
Chapter 56. (2876) Reference codes 341 Chapter 83. (4328) Reference codes 467
Chapter 57. (2890) Reference codes 343 Chapter 84. (433B) Reference codes 471
Chapter 58. (2892) Reference codes 349 Chapter 85. (433C) Reference codes 475
Chapter 59. (28B9) Reference codes 357 Chapter 86. (433D) Reference codes 479
Chapter 60. (28CB) Reference codes 359 Chapter 87. (4685) Reference codes 483
Chapter 61. (28CC) Reference codes 361 Chapter 88. (4758) Reference codes 489
Chapter 62. (293C) Reference codes 363 Chapter 89. (4764) Reference codes 491
Chapter 63. (293D) Reference codes 365 Chapter 90. (4765) Reference codes 493
Chapter 64. (297D) Reference codes 367 Chapter 91. (4812) Reference codes 495
Chapter 65. (2A39) Reference codes 369 Chapter 92. (506D) Reference codes 499
Chapter 66. (2B6C) Reference codes 371 Chapter 93. (506E) Reference codes 501
Chapter 67. (2BBE) Reference codes 373 Chapter 94. (509A) Reference codes 503
Chapter 68. (2BD6) Reference codes 375 Chapter 95. (509D) Reference codes 505
Chapter 69. (2BD8) Reference codes 377 Chapter 96. (50A4) Reference codes 507
Chapter 70. (2BD9) Reference codes 379 Chapter 97. (5619) Reference codes 509
Chapter 71. (2BE0) Reference codes 395 Chapter 98. (5638) Reference codes 515
Chapter 72. (2BE1) Reference codes 411 Chapter 99. (5675) Reference codes 521
Chapter 73. (2BE2) Reference codes 427 Chapter 100. (5700) Reference codes 527
Chapter 74. (3494) Reference codes 429 Chapter 101. (5701) Reference codes 529
Chapter 75. (3580) Reference codes 431 Chapter 102. (5702) Reference codes 531
Chapter 104. (5704) Reference codes 551 Chapter 131. (576A) Reference codes 755
Chapter 105. (5706) Reference codes 553 Chapter 132. (576B) Reference codes 757
Chapter 106. (5707) Reference codes 555 Chapter 133. (576C) Reference codes 761
Chapter 107. (5708) Reference codes 557 Chapter 134. (576D) Reference codes 763
Chapter 108. (5709) Reference codes 561 Chapter 135. (576E) Reference codes 765
Chapter 109. (570B) Reference codes 569 Chapter 136. (5774) Reference codes 767
Chapter 110. (571A) Reference codes 581 Chapter 137. (577D) Reference codes 771
Chapter 111. (571B) Reference codes 591 Chapter 138. (57B3) Reference codes 775
Chapter 112. (571E) Reference codes 601 Chapter 139. (57B7) Reference codes 791
Chapter 113. (571F) Reference codes 611 Chapter 140. (57B8) Reference codes 795
Chapter 114. (572A) Reference codes 621 Chapter 141. (57C7) Reference codes 811
Chapter 115. (572B) Reference codes 637 Chapter 142. (57CD) Reference codes 827
Chapter 116. (572C) Reference codes 653 Chapter 143. (57CF) Reference codes 843
Chapter 117. (572F) Reference codes 669 Chapter 144. (57FC) Reference codes 859
Chapter 118. (573A) Reference codes 685 Chapter 145. (57FF) Reference codes 863
Chapter 119. (573B) Reference codes 687 Chapter 146. (58B0) Reference codes 873
Chapter 120. (573C) Reference codes 689 Chapter 147. (58B2) Reference codes 877
Chapter 121. (573D) Reference codes 691 Chapter 148. (58B3) Reference codes 881
Chapter 122. (573E) Reference codes 701 Chapter 149. (58B4) Reference codes 885
Chapter 123. (5746) Reference codes 711 Chapter 150. (58B5) Reference codes 889
Chapter 124. (574E) Reference codes 717 Chapter 151. (58B6) Reference codes 893
Chapter 125. (574F) Reference codes 733 Chapter 152. (5907) Reference codes 897
Chapter 126. (5755) Reference codes 737 Chapter 153. (6258) Reference codes 903
Chapter 127. (575B) Reference codes 743 Chapter 154. (6279) Reference codes 909
Chapter 128. (575C) Reference codes 747 Chapter 155. (6320) Reference codes 915
Chapter 129. (5767) Reference codes 751 Chapter 156. (6321) Reference codes 919
Contents v
Chapter 157. (632B) Reference codes 923 Chapter 173. (6714) Reference codes 997
Chapter 158. (632C) Reference codes 925 Chapter 174. (6717) Reference codes 1001
Chapter 159. (6330) Reference codes 927 Chapter 175. (6718) Reference codes 1005
Chapter 160. (6331) Reference codes 931 Chapter 176. (6719) Reference codes 1009
Chapter 161. (6333) Reference codes 935 Chapter 177. (6A59) Reference codes 1013
Chapter 162. (6336) Reference codes 939 Chapter 178. (6B25) Reference codes 1015
Chapter 163. (6337) Reference codes 943 Chapter 179. (7207) Reference codes 1017
Chapter 164. (6382) Reference codes 947 Chapter 180. (A1xx) Reference codes 1023
Chapter 165. (6383) Reference codes 953 Chapter 181. (A2xx) Reference codes 1025
Chapter 166. (6384) Reference codes 959 Chapter 182. (A6xx) Reference codes 1027
Chapter 167. (6386) Reference codes 965 Chapter 183. (A7xx) Reference codes 1057
Chapter 168. (6387) Reference codes 971 Chapter 184. (AAxx) Reference codes 1061
IBM® servers can use I/O cards or features that are fiber-optic based and that
utilize lasers or LEDs.
Laser compliance
All lasers are certified in the U.S. to conform to the requirements of DHHS 21 CFR
Subchapter J for class 1 laser products. Outside the U.S., they are certified to be in
compliance with IEC 60825 as a class 1 laser product. Consult the label on each
part for laser certification numbers and approval information.
CAUTION:
This product might contain one or more of the following devices: CD-ROM
drive, DVD-ROM drive, DVD-RAM drive, or laser module, which are Class 1
laser products. Note the following information:
v Do not remove the covers. Removing the covers of the laser product could
result in exposure to hazardous laser radiation. There are no serviceable parts
inside the device.
v Use of the controls or adjustments or performance of procedures other than
those specified herein might result in hazardous radiation exposure.
(C026)
CAUTION:
This product contains a Class 1M laser. Do not view directly with optical
instruments. (C028)
CAUTION:
Some laser products contain an embedded Class 3A or Class 3B laser diode.
Note the following information: laser radiation when open. Do not stare into the
beam, do not view directly with optical instruments, and avoid direct exposure
to the beam. (C030)
The following comments apply to the IBM servers that have been designated as
conforming to NEBS (Network Equipment-Building System) GR-1089-CORE:
Note: All Ethernet cables must be shielded and grounded at both ends.
The ac-powered system does not require the use of an external surge protection
device (SPD).
Reference codes are diagnostic aids that help you determine the source of a
hardware or operating system problem. Using a reference code enables you to find
the solution to fix the problem. To use reference codes effectively, you must use
them in conjunction with other service and support procedures.
Note: System reference codes (SRCs) often indicate failing items. Some failing
items are required to be exchanged in groups until the problem is solved. Other
failing items are flagged as mandatory exchange and must be exchanged before the
service action is complete, even if the problem appears to have been repaired. For
more information, see “Block replacement of FRUs.”
The priorities of performing the FRU replacements or procedures are shown in the
following ways, depending on how you view the SAL.SRC:
v Advanced System Management Interface (ASMI): The ASMI shows a priority
with each callout in the log.
v Control panel: The control panel shows one of the following priorities with each
callout:
– H = High
– M = Medium
– MA = Medium group A
– MB = Medium group B
– MC = Medium group C
– L = Low
v Hardware Management Console (HMC): In the Service Focal Point on the HMC,
the view of the problem data for a serviceable event displays the FRU
replacement priority as High, Medium, and so on.
100000AA 100000AA
10001503 10001503
Explanation: Download in process
Explanation: Power supply failure
Response: No action required. This reference code is
Response: Follow the instructions for the items listed
logged for information only.
in the FRU List.
Failing Item:
100000AC 100000AC
v PWRSPLY
Explanation: Detected AC loss
v TWRCARD
Response: If system powers on normally or stays
powered on after AC power failure, no replacement of
10001507 10001507
parts may be needed. If parts are replaced, follow the
instructions for the items listed in the FRU List. Explanation: Power supply plugging ID error
Failing Item: Response: Follow the instructions for the items listed
v ACMODUL in the FRU List.
Failing Item:
100000AD 100000AD v PWRSPLY
Explanation: A reset of the service processor caused v VPDPART
the system to power off.
10001510 10001510
10001500 10001500 Explanation: Detected AC loss
Explanation: Detected AC loss Response: Before replacing any parts, verify that the
Response: Before replacing any parts, verify that the AC input voltage is correct. Follow the instructions for
AC input voltage is correct, follow the instructions for the items listed in the FRU List.
the items listed in the FRU List. Problem determination: No additional problem
Failing Item: determination.
v PWRSPLY Failing Item:
v TWRCARD v PWRSPLY
v TWRCARD
10001501 10001501
Explanation: Power supply failure 10001511 10001511
Response: Follow the instructions for the items listed Explanation: Power supply failure
in the FRU List. Response: Follow the instructions for the items listed
Failing Item: in the FRU List.
v PWRSPLY Failing Item:
v TWRCARD v PWRSPLY
v TWRCARD
10001520 10001520
Explanation: Detected AC loss
10001512 10001512
Response: Before replacing any parts, verify that the
Explanation: Power supply failure
AC input voltage is correct, follow the instructions for
Response: Follow the instructions for the items listed the items listed in the FRU List.
in the FRU List.
Failing Item:
Failing Item: v PWRSPLY
v PWRSPLY v TWRCARD
v TWRCARD
v CBLALL 10001521 10001521
Explanation: Power supply failure
10001513 10001513
Response: Follow the instructions for the items listed
Explanation: Power supply failure in the FRU List.
Response: Follow the instructions for the items listed Failing Item:
in the FRU List.
v PWRSPLY
Failing Item: v TWRCARD
v PWRSPLY
v TWRCARD 10001522 10001522
Explanation: Power supply failure
10001514 10001514
Response: Follow the instructions for the items listed
Explanation: Power supply failure in the FRU List.
Response: Follow the instructions for the items listed Failing Item:
in the FRU List.
v PWRSPLY
Failing Item: v TWRCARD
v PWRSPLY v CBLALL
v TWRCARD
10001523 10001523
10001516 10001516
Explanation: Power supply failure
Explanation: No power supplies are present
Response: Follow the instructions for the items listed
Response: The required power supplies are not in the FRU List.
installed. Follow the instructions for the items listed in
Failing Item:
the FRU List.
v PWRSPLY
Failing Item:
v TWRCARD
v PWRSPLY
v TWRCARD
10001524 10001524
Explanation: Power supply failure
10001517 10001517
Response: Follow the instructions for the items listed
Explanation: Power supply failure
in the FRU List.
Response: Follow the instructions for the items listed
Failing Item:
in the FRU List.
v PWRSPLY
Failing Item:
v TWRCARD
v PWRSPLY
v VPDPART
v TWRCARD
Failing Item:
10001B04 10001B04
v PGDPART
Explanation: Load fault on the -12V bus
Response: Follow the instructions for the items listed 10002605 10002605
in the FRU List.
Explanation: Power-good fault
Failing Item:
Response: Follow the instructions for the items listed
v PWR1900
in the FRU List.
v TWRCARD
Failing Item:
v PWR1900
10001B18 10001B18
v TWRCARD
Explanation: Load fault on the +1.5V bus
Response: Follow the instructions for the items listed 10002606 10002606
in the FRU List.
Explanation: Power-good fault
Failing Item:
Response: Follow the instructions for the items listed
v PWR1900
in the FRU List.
Failing Item:
10001DA0 10001DA0
v PWR1900
Explanation: I/O planar SPCN fault
v TWRCARD
Response: Follow the instructions for the items listed
in the FRU List.
10002607 10002607
Failing Item:
Explanation: Power-good fault
v PWR1900
Response: Follow the instructions for the items listed
in the FRU List.
10001F02 10001F02
Failing Item:
Explanation: SPCN trace information saved
v PWR1900
Response: No action required. This reference code is v TWRCARD
logged for information only.
10002608 10002608
10002600 10002600
Explanation: Power-good fault
Explanation: Power-good fault
Response: Follow the instructions for the items listed
Response: Follow the instructions for the items listed in the FRU List.
in the FRU List.
Failing Item:
Failing Item:
v PWR1900
v PGDPART
v TWRCARD
10002601 10002601
10002609 10002609
Explanation: Power-good fault
Explanation: Power-good fault
Response: Follow the instructions for the items listed
Response: Follow the instructions for the items listed
in the FRU List.
in the FRU List.
Failing Item:
Failing Item:
v PGDPART
v PWR1900
v TWRCARD
10002603 10002603
Explanation: Power-good fault
Response: Follow the instructions for the items listed
in the FRU List.
Failing Item:
10002612 10002612
v I2CBUS
Explanation: Optical Converter 5V Fault
v TWRCARD
Response: The SPCN detected a fault on the SPCN
card optical converter 5V. Follow the instructions for
10003105 10003105
the items listed in the FRU List.
Explanation: I2C bus 5 communication fault
Failing Item:
v CBLALL Response: Follow the instructions for the items listed
in the FRU List.
v TWRCARD
Failing Item:
10003100 10003100 v I2CBUS
v TWRCARD
Explanation: I2C bus controller communication fault
Response: Follow the instructions for the items listed
10003106 10003106
in the FRU List.
Explanation: I2C bus 6 communication fault
Failing Item:
v I2CBUS Response: Follow the instructions for the items listed
in the FRU List.
v TWRCARD
Failing Item:
10003101 10003101 v I2CBUS
v TWRCARD
Explanation: I2C bus 1 communication fault
Response: Follow the instructions for the items listed
1000310A 1000310A
in the FRU List.
Explanation: I2C bus SPCN VPD communication fault
Failing Item:
v I2CBUS Response: Follow the instructions for the items listed
in the FRU List.
v TWRCARD
Failing Item:
10003102 10003102 v I2CBUS
v TWRCARD
Explanation: I2C bus 2 communication fault
Response: Follow the instructions for the items listed
1000310B 1000310B
in the FRU List.
Explanation: I2C bus SPCN VPD communication fault
Failing Item:
v I2CBUS Response: Follow the instructions for the items listed
in the FRU List.
v TWRCARD
Failing Item:
10003103 10003103 v I2CBUS
v TWRCARD
Explanation: I2C bus 3 communication fault
Response: Follow the instructions for the items listed
10003110 10003110
in the FRU List.
Explanation: I2C bus DASD backplane 1
Failing Item:
communication fault
v I2CBUS
Response: Follow the instructions for the items listed
v TWRCARD
in the FRU List.
Failing Item:
10003104 10003104
v I2CBUS
Explanation: I2C bus 4 communication fault
v TWRCARD
Response: Follow the instructions for the items listed
in the FRU List.
Failing Item:
10003144 10003144
v I2CBUS
Explanation: DCA0 I2C multiplexer (MUX) error
v TWRCARD
Response: Follow the instructions for the items listed
in the FRU List.
10003125 10003125
Failing Item:
Explanation: I2C bus SPCN VPD communication fault
v PWRSPLY
Response: Follow the instructions for the items listed
in the FRU List.
10003145 10003145
Failing Item:
Explanation: DCA0 I2C error
v I2CBUS
v TWRCARD Response: Follow the instructions for the items listed
in the FRU List.
v PWRSPLY v I2CBUS
v PWRSPLY
1000314A 1000314A
Explanation: Port card 3 I2C error 10004600 10004600
Response: Follow the instructions for the items listed Explanation: UPS Interface Failure
in the FRU List. Response: Follow the instructions for the items listed
Failing Item: in the FRU List.
v I2CBUS Failing Item:
v PWRSPLY v UPSUNIT
v TWRCARD
1000314B 1000314B
Explanation: Port card 4 I2C error 10004601 10004601
Response: Follow the instructions for the items listed Explanation: UPS Interface Failure
in the FRU List. Response: Follow the instructions for the items listed
Failing Item: in the FRU List.
v I2CBUS Failing Item:
v PWRSPLY v UPSUNIT
v TWRCARD
10003154 10003154
Explanation: DCA1 I2C multiplexer (MUX) error 10006000 10006000
Response: Follow the instructions for the items listed Explanation: Midplane VPD error
in the FRU List. Response: Follow the instructions for the items listed
Failing Item: in the FRU List.
v PWRSPLY Failing Item:
v VPDPART
10003155 10003155
Explanation: DCA1 I2C error 10006001 10006001
Response: Follow the instructions for the items listed Explanation: Conduit card VPD data error
in the FRU List. Response: Follow the instructions for the items listed
Failing Item: in the FRU List.
v PWRSPLY Failing Item:
v I2CBUS v VPDPART
Response: Follow the instructions for the items listed Failing Item:
in the FRU List. v AIRMOVR
Failing Item: v TWRCARD
v AIRMOVR
10007621 10007621
10007602 10007602 Explanation: Fan missing error
Explanation: DCA1: fan 1 fault Response: A problem was detected with a Fan which
can be caused by a Fan not being installed. Install Fan
Response: Follow the instructions for the items listed if missing, replace if already installed. Follow the
in the FRU List. instructions for the items listed in the FRU List.
Failing Item: Failing Item:
v AIRMOVR v AIRMOVR
v TWRCARD
by product engineering to debug system power control the failure. Follow the instructions for the items listed
network (SPCN) failures. in the FRU List.
Failing Item:
10009021 10009021 v TWRCARD
Explanation: A command to an SPCN node was
rejected. 1000902D 1000902D
Response: No action required. This reference code is Explanation: Addressed frame is not in SPCN
logged for information only. configuration table.
Response: The addressed frame is not in the SPCN
10009022 10009022 configuration table. No action required. This reference
Explanation: Addressed Unit not in frame. code is logged for information only.
Explanation: SPCN Licensed Internal Code is not Response: A secondary node detected a BCC error on
valid. a transmission from the frame. The transmission is
attempted again. No action required. This reference
Response: The Licensed Internal Code in one of the code is logged for error analysis only.
frames is not valid. The code will be reloaded. No
action required. This reference code is logged for error
analysis only. 10009034 10009034
Explanation: Unsupported Packet Size
10009028 10009028 Response: The receiving node detected a packet
Explanation: SPCN Licensed Internal Code is not exceeding 70 bytes. The frame can also return this code
valid. if a secondary node returns more than 10 bytes to a
PAS command. No action required. This reference code
Response: The Licensed Internal Code in the primary is logged for error analysis only.
node is not valid. The code will be reloaded. No action
required. This reference code is logged for error
analysis only. 10009035 10009035
Explanation: Secondary SPCN node timeout.
10009029 10009029 Response: A secondary SPCN node did not respond
Explanation: SPCN VPD Damaged to a command. The command was attempted again and
failed. No action required. This reference code is logged
Response: The VPD record in the EEPROM has bad for error analysis only.
data. Exchange the failing items for the node reporting
Failing Item:
10009036 10009036
v TWRCARD
Explanation: Frame Timeout
Response: One or more frames did not respond to a 10009047 10009047
command. The command is attempted again. No action
required. This reference code is logged for error Explanation: QDS Block Sequence Error
analysis only. Response: The Block Sequence number is wrong. The
download was stopped. Follow the instructions for the
1000903B 1000903B items listed in the FRU List.
Failing Item:
10009080 10009080
v AJDG301
v TWRCARD Explanation: Undefined Status Code
Response: An SPCN node returned an unknown
10009042 10009042 status code. Exchange the failing SPCN node. Follow
the instructions for the items listed in the FRU List.
Explanation: EEPROM Failure
Failing Item:
Response: The EEPROM in an SPCN node cannot be v TWRCARD
written successfully. Exchange the SPCN node reported
in the failure. Follow the instructions for the items v SYSBKPL
listed in the FRU List.
Failing Item: 10009088 10009088
v PWR1907 v TWRCARD
v TWRCARD
v CBLALL 10009104 10009104
Explanation: Download Completion Timeout
100090F1 100090F1
Response: An SPCN node failed to leave the
Explanation: A frame was added to the SPCN download state. Exchange the failing SPCN node.
configuration. Follow the instructions for the items listed in the FRU
List.
Response: No action required. This reference code is
logged for information only. Failing Item:
v TWRCARD
100090F2 100090F2
Explanation: Slave disappeared 10009105 10009105
Response: A slave was dropped from the SPCN Explanation: Load Damaged Timeout
configuration. This is usually caused by a loss of ac Response: An SPCN node failed to enter the
power. If this SRC is logged during a concurrent operational state. Exchange the failing SPCN node.
maintenance operation, it is informational only and can Follow the instructions for the items listed in the FRU
be ignored. List.
Failing Item:
100090F3 100090F3
v TWRCARD
Explanation: Slave reappeared
Response: No action required. This reference code is 10009106 10009106
logged for information only.
Explanation: An SPCN LID was not found.
Response: No action required. This reference code is
10009101 10009101
logged for information only.
Explanation: VLIC-SPCN Timeout
Response: A Licensed Internal Code timeout occurred. 10009107 10009107
The SPCN failed to respond to a Licensed Internal
Explanation: An SPCN microcode download is
Code command. Follow the instructions for the items
required.
listed in the FRU List.
Response: No action required. This reference code is
Failing Item:
logged for error analysis only.
v TWRCARD
10009108 10009108
10009102 10009102
Explanation: A status change occurred in one of the
Explanation: Assign Permanent Address command SPCN nodes.
failure
Response: No action required. This reference code is
Response: A node failed to perform an Assign logged for information only.
Permanent Address command. Follow the instructions
for the items listed in the FRU List.
10009109 10009109
Failing Item:
Explanation: Licensed Internal Code part number is
v TWRCARD
not correct.
Response: The AROS part number field was not
10009103 10009103
updated to the correct level after the system attempted
Explanation: Download Initialize Timeout to load new Licensed Internal Code. Follow the
instructions for the items listed in the FRU List.
Response: An SPCN node failed to enter the
download state after an Initialize for Download Failing Item:
command. Exchange the failing SPCN node. Follow the v TWRCARD
instructions for the items listed in the FRU List.
Failing Item:
v TWRCARD
1000910A 1000910A
Explanation: RIO Download Required
10009115 10009115
Response: No action required. This reference code is
Explanation: SPCN Command rejected by the
logged for information only.
firmware.
Response: The service processor rejected an SPCN
1000910B 1000910B
command from the Licensed Internal Code. No action
Explanation: Maximum number of retries exceeded required. This reference code is logged for information
only.
Response: No action required. This reference code is
logged for information only.
10009116 10009116
10009111 10009111 Explanation: SPCN - Control Panel interface failure.
Explanation: SPCN is too large for hypervisor. Response: The SPCN to control panel interface is not
working.
Response: There are more nodes in the network than
the hypervisor can service. Go to System Configuration
in ASMI . Under Configure I/O Enclosures select Clear 10009117 10009117
Inactive Enclosures. If the error persists follow the
Explanation: SPCN - Control Panel interface is now
instructions for the items listed in the FRU List.
working.
Failing Item:
Response: The SPCN to control panel interface is now
v AJDG301 working. No action required. This reference code is
logged for information only.
10009112 10009112
Explanation: Primary SPCN node is reporting load 10009118 10009118
damaged. Explanation: Hypervisor out of memory
Response: The Licensed Internal Code for the primary Response: Follow the instructions for the items listed
SPCN node is damaged. The reload failed because the in the FRU List.
code could not be found. Follow the instructions for the
items listed in the FRU List. Failing Item:
v AJDG301
Failing Item:
v TWRCARD
10009119 10009119
Explanation: Secondary SPCN node is reporting load Response: Follow the instructions for the items listed
damaged. in the FRU List.
Response: Call your next level of support. Explanation: The manually started download was
interrupted
Failing Item:
10009139 10009139
v TWRCARD
Explanation: Open SPCN loop resolved
Response: No action required. This reference code is
logged for information only.
1000913A 1000913A
Explanation: RIO download sent retry
Response: No action required. This reference code is
logged for information only.
1000913B 1000913B
Explanation: Go to ASMi to start a download
manually
Response: Follow the instructions for the items listed
in the FRU List.
Failing Item:
v PWR1907
100091DD 100091DD
Explanation: All SPCN Downloads Complete
Response: No action required. This reference code is
logged for information only.
100091DE 100091DE
Explanation: RIO Download Complete
Response: No action required. This reference code is
logged for information only.
100091FB 100091FB
Explanation: Write VPD on next IPL
Response: No action required. This reference code is
logged for information only.
1000C62E 1000C62E
Explanation: Polling error
Response: An SPCN frame-to-frame communication
failure was detected. Follow the instructions for the
items listed in the FRU List.
Failing Item:
v TWRCARD
v CBLALL
1000CB15 1000CB15
Explanation: EEPROM Failure.
Response: Follow the instructions for the items listed
in the FRU List.
11001512 11001512
Failing Item:
11001611 11001611
v PWR1918
Explanation: Regulator 1 Fault
v TWRCARD
Response: Follow the instructions for the items listed
in the FRU List.
11001623 11001623
Problem determination: No additional problem
Explanation: Regulator 2 Domain Fault
determination.
Response: Follow the instructions for the items listed
Failing Item:
in the FRU List.
v PWR1918
Problem determination: No additional problem
v TWRCARD
determination.
Failing Item:
11001612 11001612
v PWR1918
Explanation: Regulator 1 Communication Fault
v TWRCARD
Response: Follow the instructions for the items listed
in the FRU List.
11001631 11001631
Problem determination: No additional problem
Explanation: Regulator 3 Fault
determination.
Response: Follow the instructions for the items listed
Failing Item:
in the FRU List.
v PWR1918
Problem determination: No additional problem
v TWRCARD
determination.
Failing Item:
11001613 11001613
v PWR1918
Explanation: Regulator 1 Domain Fault
v TWRCARD
Response: Follow the instructions for the items listed
in the FRU List.
11001632 11001632
Problem determination: No additional problem
Explanation: Regulator 3 Communication Fault
determination.
Response: Follow the instructions for the items listed
Failing Item:
in the FRU List.
v PWR1918
Problem determination: No additional problem
v TWRCARD
determination.
Failing Item:
11001621 11001621
v PWR1918
Explanation: Regulator 2 Fault
v TWRCARD
Response: Follow the instructions for the items listed
in the FRU List.
11001633 11001633
Problem determination: No additional problem
Explanation: Regulator 3 Domain Fault
determination.
Response: Follow the instructions for the items listed
Failing Item:
in the FRU List.
v PWR1918
Problem determination: No additional problem
v TWRCARD
determination.
Failing Item:
11001622 11001622
v PWR1918
Explanation: Regulator 2 Communication Fault
v TWRCARD
Response: Follow the instructions for the items listed
in the FRU List.
Problem determination: No additional problem
determination.
Response: Follow the instructions for the items listed Explanation: Power Good Fault
in the FRU List. Response: Follow the instructions for the items listed
Problem determination: No additional problem in the FRU List.
determination. Problem determination: No additional problem
Failing Item: determination.
v SI_CARD Failing Item:
v TWRCARD v PWR1918
v TWRCARD
11001D68 11001D68
Explanation: HEA adapter card 2 softswitch fault 11002603 11002603
Response: Follow the instructions for the items listed Explanation: Power Good Fault
in the FRU List. Response: Follow the instructions for the items listed
Problem determination: No additional problem in the FRU List.
determination. Problem determination: No additional problem
determination.
11001F01 11001F01 Failing Item:
Explanation: TMS limit reached - log only v PGDPART
Response: No action required. This reference code is
logged for information only. 11002610 11002610
Problem determination: No additional problem Explanation: A power signal failure has been detected
determination.
Response: Follow the instructions for the items listed
in the FRU List.
11001F02 11001F02
Problem determination: No additional problem
Explanation: SPCN trace information saved determination.
Response: No action required. This reference code is Failing Item:
logged for information only. v SYSBKPL
Problem determination: No additional problem
determination. 11002611 11002611
Explanation: A power signal failure has been detected
11001F03 11001F03
Response: Follow the instructions for the items listed
Explanation: Invalid TMS or location code; log only. in the FRU List.
Response: No action required. This reference code is Problem determination: No additional problem
logged for information only. determination.
Problem determination: No additional problem Failing Item:
determination.
v SYSBKPL
11002600 11002600
11002613 11002613
Explanation: Power Good Fault
Explanation: 100V check fault
Response: Follow the instructions for the items listed
Response: Follow the instructions for the items listed
in the FRU List.
in the FRU List.
Explanation: 1.8V power-good input fault Response: Follow the instructions for the items listed
in the FRU List.
Response: Follow the instructions for the items listed
in the FRU List. Problem determination: No additional problem
determination.
Problem determination: No additional problem
determination. Failing Item:
v SYSBKPL
Failing Item:
v PWR1918
1100262A 1100262A
Explanation: GX slot 2 pgood fault.
Response: Follow the instructions for the items listed
in the FRU List.
Explanation: DASD 5V regulator P_GOOD fault. Response: Follow the instructions for the items listed
in the FRU List.
Response: Follow the instructions for the items listed
in the FRU List. Problem determination: No additional problem
determination.
Problem determination: No additional problem
determination. Failing Item:
v PWR1918
Failing Item:
v ANYPROC
v PWR1918
v SYSBKPL
1100262D 1100262D
11002633 11002633
Explanation: P_GOOD fault on the I/O backplane.
Explanation: Processor 1 1.2V VRM power-good fault
Response: Follow the instructions for the items listed
in the FRU List. Response: Follow the instructions for the items listed
in the FRU List.
Problem determination: No additional problem
determination. Problem determination: No additional problem
determination.
Failing Item:
Failing Item:
v SYSBKPL
v PWR1918
v SYSBKPL
1100262E 1100262E
Explanation: P_GOOD fault on the I/O backplane.
11002634 11002634
Response: Follow the instructions for the items listed
Explanation: Processor 1 1.8V VRM or processor 1
in the FRU List.
power-good fault
Problem determination: No additional problem
Response: Follow the instructions for the items listed
determination.
in the FRU List.
Failing Item:
Problem determination: No additional problem
v SYSBKPL determination.
Failing Item:
1100262F 1100262F
v ANYPROC
Explanation: P_GOOD fault on the I/O backplane. v SYSBKPL
Response: Follow the instructions for the items listed
in the FRU List. 11002635 11002635
Problem determination: No additional problem Explanation: VRM fault on the processor card.
determination.
Response: Follow the instructions for the items listed
Failing Item: in the FRU List.
Problem determination: No additional problem Response: Follow the instructions for the items listed
determination. in the FRU List.
Failing Item: Problem determination: No additional problem
v PWR1918 determination.
Failing Item:
11002636 11002636 v PWR1918
Explanation: VRM fault on the processor card. v ANYPROC
v SYSBKPL
Response: Follow the instructions for the items listed
in the FRU List.
11002643 11002643
Problem determination: No additional problem
determination. Explanation: Processor 2 1.8V VRM or processor 2
power-good fault
Failing Item:
v PWR1918 Response: Follow the instructions for the items listed
in the FRU List.
Explanation: Memory card 1 pgood fault. Response: Follow the instructions for the items listed
in the FRU List.
Response: Follow the instructions for the items listed
in the FRU List. Problem determination: No additional problem
determination.
Problem determination: No additional problem
determination. Failing Item:
v PWR1918
1100263C 1100263C
1100264A 1100264A
Explanation: Memory card 1 pgood fault.
Explanation: Memory card 2 pgood fault.
Response: Follow the instructions for the items listed
in the FRU List. Response: Follow the instructions for the items listed
in the FRU List.
Problem determination: No additional problem
determination. Problem determination: No additional problem
determination.
11002640 11002640
1100264B 1100264B
Explanation: Processor 1 P7_VRM pgood fault
(pluggable) Explanation: Memory card 2 pgood fault.
Response: Follow the instructions for the items listed Response: Follow the instructions for the items listed
in the FRU List. in the FRU List.
Problem determination: No additional problem Problem determination: No additional problem
determination. determination.
Explanation: Processor 3 VRM2 array power-good Explanation: Memory card 3 pgood fault.
fault Response: Follow the instructions for the items listed
Response: Follow the instructions for the items listed in the FRU List.
in the FRU List. Problem determination: No additional problem
Problem determination: No additional problem determination.
determination.
Failing Item: 11002660 11002660
v PWR1918 Explanation: Processor 4 VRM 1A or 1B power-good
v ANYPROC fault
v SYSBKPL Response: Follow the instructions for the items listed
in the FRU list.
11002653 11002653 Problem determination: No additional problem
determination.
Explanation: Processor 3 1.2V VRM power-good fault
Failing Item:
Response: Follow the instructions for the items listed
in the FRU list. v PWR1918
v ANYPROC
Problem determination: No additional problem
determination. v SYSBKPL
Failing Item:
11002662 11002662
v PWR1918
v SYSBKPL Explanation: Processor 4 VRM2 array power-good
fault
11002654 11002654 Response: Follow the instructions for the items listed
in the FRU list.
Explanation: Processor 3 1.8V VRM or processor 3
power-good fault Problem determination: No additional problem
determination.
Response: Follow the instructions for the items listed
in the FRU list. Failing Item:
v PWR1918
Problem determination: No additional problem
determination. v ANYPROC
v SYSBKPL
Failing Item:
v ANYPROC
v SYSBKPL
1100266A 1100266A Response: Follow the instructions for the items listed
in the FRU List.
Explanation: Memory card 4 pgood fault.
Problem determination: No additional problem
Response: Follow the instructions for the items listed determination.
in the FRU List.
Failing Item:
Problem determination: No additional problem
v PWR1918
determination.
11002702 11002702
1100266B 1100266B
Explanation: VRM fault on the DASD backplane.
Explanation: Memory card 4 pgood fault.
Response: Follow the instructions for the items listed
Response: Follow the instructions for the items listed
in the FRU List.
in the FRU List.
Problem determination: No additional problem
Problem determination: No additional problem
determination.
determination.
Failing Item:
1100266C 1100266C v PWR1918
Problem determination: No additional problem Response: Follow the instructions for the items listed
determination. in the FRU List.
Problem determination: No additional problem
11002690 11002690 determination.
v TWRCARD v AIRMOVR
v TWRCARD
11007621 11007621
11007641 11007641
Explanation: Fan missing error
Explanation: A problem was detected with a fan
Response: A problem was detected with a fan which which can be caused by a fan not being installed.
can be caused by a fan not being installed. Install fan if Install the fan if it is missing; replace it if already
missing, replace if already installed. Follow the installed. Follow the instructions for the items listed in
instructions for the items listed in the FRU List. the FRU list.
Problem determination: No additional problem Response: Follow the instructions for the items listed
determination. in the FRU List.
Failing Item: Problem determination: No additional problem
v AIRMOVR determination.
v TWRCARD Failing Item:
installed. Follow the instructions for the items listed in Problem determination: No additional problem
the FRU list. determination.
Response: Follow the instructions for the items listed
in the FRU List. 11008400 11008400
Problem determination: No additional problem Explanation: No VPD was found due to invalid
determination. bypass
Failing Item: Response: Follow the instructions for the items listed
v AIRMOVR in the FRU List.
v TWRCARD Problem determination: No additional problem
determination.
110076B0 110076B0 Failing Item:
Explanation: A problem was detected with a fan. v AJDG301
Follow the instructions for the items listed in the FRU
list. 11008402 11008402
Response: Follow the instructions for the items listed Explanation: Unable to collect VPD
in the FRU List.
Response: Follow the instructions for the items listed
Problem determination: No additional problem in the FRU List.
determination.
Problem determination: No additional problem
Failing Item: determination.
v AIRMOVR
Failing Item:
v TWRCARD
v VPDPART
v TWRCARD
110076B1 110076B1
Explanation: A problem was detected with a fan 11008404 11008404
which can be caused by a fan not being installed.
Install the fan if it is missing; replace it if already Explanation: Processor unit VPD mismatch
installed. Follow the instructions for the items listed in Response: Follow the instructions for the items listed
the FRU list. in the FRU List.
Response: Follow the instructions for the items listed Problem determination: No additional problem
in the FRU List. determination.
Problem determination: No additional problem Failing Item:
determination.
v VPDPART
Failing Item: v TWRCARD
v AIRMOVR
v TWRCARD 11008405 11008405
Explanation: Processor unit VPD mismatch
110076C0 110076C0
Response: Follow the instructions for the items listed
Explanation: Fan fault on a GX++ adapter card in the FRU List.
Response: Follow the instructions for the items listed Problem determination: No additional problem
in the FRU List. determination.
Problem determination: No additional problem Failing Item:
determination.
v VPDPART
v TWRCARD
110076C1 110076C1
Explanation: Fan fault on a GX++ adapter card
Response: Follow the instructions for the items listed
in the FRU List.
Failing Item:
11008406 11008406
v ANYPROC
Explanation: Processor unit VPD mismatch
Response: Follow the instructions for the items listed 11008416 11008416
in the FRU List.
Explanation: Invalid processor 4 VPD
Problem determination: No additional problem
determination. Response: Follow the instructions for the items listed
in the FRU List.
Failing Item:
Problem determination: No additional problem
v VPDPART
determination.
v TWRCARD
Failing Item:
v ANYPROC
11008409 11008409
Explanation: No processor installed
11008423 11008423
Response: Follow the instructions for the items listed
Explanation: No processor VPD
in the FRU List.
Response: Follow the instructions for the items listed
Problem determination: No additional problem
in the FRU List.
determination.
Problem determination: No additional problem
Failing Item:
determination.
v VPDPART
Failing Item:
v TWRCARD
v VPDPART
v TWRCARD
11008413 11008413
Explanation: Invalid processor VPD
11008424 11008424
Response: Follow the instructions for the items listed
Explanation: No processor VPD
in the FRU List.
Response: Follow the instructions for the items listed
Problem determination: No additional problem
in the FRU List.
determination.
Problem determination: No additional problem
Failing Item:
determination.
v VPDPART
Failing Item:
v TWRCARD
v VPDPART
v TWRCARD
11008414 11008414
Explanation: Invalid processor VPD
11008442 11008442
Response: Follow the instructions for the items listed
Explanation: An attempt was made to enable
in the FRU List.
TurboMode, but one or more processor cards in the
Problem determination: No additional problem system is not TurboMode-capable.
determination.
Response: Follow the instructions for the items listed
Failing Item: in the FRU List.
v VPDPART Problem determination: No additional problem
v TWRCARD determination.
Failing Item:
11008415 11008415 v VPDPART
Explanation: Invalid processor 3 VPD
Response: Follow the instructions for the items listed
in the FRU List.
Problem determination: No additional problem
determination.
Failing Item:
11008443 11008443
v PWRSPLY
Explanation: A drawer was added to a system that
v TWRCARD
has TurboMode enabled, but the newly-added drawer
is not TurboMode-capable.
11008453 11008453
Response: Follow the instructions for the items listed
in the FRU List. Explanation: There is an extra processor voltage
regulator in the system.
Problem determination: No additional problem
determination. Response: Follow the instructions for the items listed
in the FRU List.
Failing Item:
v VPDPART Problem determination: No additional problem
determination.
v TWRCARD
11008457 11008457
Explanation: The wrong processor VRMs are installed
110084A3 110084A3
in the system; high-power VRMs are required.
Explanation: Invalid service processor card VPD
Response: Follow the instructions for the items listed
in the FRU List. Response: Follow the instructions for the items listed
in the FRU List.
Problem determination: No additional problem
determination. Problem determination: No additional problem
determination.
Failing Item:
v PWR1918 Failing Item:
v TWRCARD v VPDPART
v TWRCARD
11008460 11008460
110084A4 110084A4
Explanation: All PWR nodes guarded
Explanation: Service processor card mismatch.
Response: No action required. This reference code is
logged for information only. Response: Follow the instructions for the items listed
in the FRU List.
Problem determination: No additional problem
determination. Problem determination: No additional problem
determination.
11008480 11008480 Failing Item:
Explanation: The DIMM or DIMM controller ID data v VPDPART
is missing or corrupt. v TWRCARD
Response: No action required. This reference code is
logged for information only. 11008700 11008700
Problem determination: No additional problem Explanation: BPC A lost input power
determination.
Response: Follow the instructions for the items listed
Failing Item: in the FRU list.
v FSPSP04 Problem determination: No additional problem
determination.
110084A1 110084A1 Failing Item:
Explanation: Invalid power distribution backplane v PWR2402
VPD
Response: Follow the instructions for the items listed 11008701 11008701
in the FRU List.
Explanation: BPC B lost input power
Problem determination: No additional problem
determination. Response: Follow the instructions for the items listed
in the FRU list.
Failing Item:
Problem determination: No additional problem
v VPDPART determination.
Failing Item:
110084A2 110084A2
v PWR2402
Explanation: Power distribution backplane mismatch
Response: Follow the instructions for the items listed 11008710 11008710
in the FRU List.
Explanation: DCA 1 UART communication fault
Problem determination: No additional problem
determination. Response: Follow the instructions for the items listed
in the FRU list.
Failing Item:
Problem determination: No additional problem
v VPDPART determination.
Note: Serviceable actions for the following SRCs require that you use the Service
focal point application on the HMC to access more specific information, including
isolation procedures, MAPs, and instruction on how to remove and replace parts.
14000064 14000064
14000059 14000059
Explanation: Air Moving Device number five is
Explanation: There is a problem with the BPJ. See defective.
Power fault reason for details.
Failing Item:
Failing Item:
v MDAA-5
v BPJ-B
v MSAA-5
14000060 14000060
14000065 14000065
Explanation: Air Moving Device number one is
Explanation: Air Moving Device number six is
defective.
defective.
Failing Item:
Failing Item:
v MDAA-1
v MDAA-6
v MSAA-1
v MSAA-6
14000061 14000061
14000072 14000072
Explanation: Air Moving Device number two is
Explanation: The ambient room temperature is out of
defective.
specification. The sensors are located in the EPO panel
Failing Item: and read/converted by the BPC. The byte 3 value
v MDAA-2 indicates the temperature threshold.
v MSAA-2 Failing Item:
v NOT_A_BPA_FRU
14000062 14000062
Explanation: Air Moving Device number three is 14000078 14000078
defective. Explanation: Logic on a PU book has reached a
Failing Item: warning level. Next level of support should be notified
of potential problem.
v MDAA-3
v MSAA-3
14000079 14000079
Failing Item:
140000F2 140000F2
v ANY-NODE
Explanation: The temperature sensed in a PU book is
approaching a critical level. Next level of support
1400007D 1400007D should be notified of potential problem.
Explanation: LGA shorts test has failed.
Failing Item: 140000F3 140000F3
v MCM1 Explanation: The temperature sensed in a PU book
v MCM2 has returned to normal. Next level of support should
be notified of potential problem.
v ANY-NODE
140000F4 140000F4
1400007E 1400007E
Explanation: The room temperature sensed at the
Explanation: There is a problem with sensed and UEPO switch has returned to normal. Next level of
passed configuration of the MCMs that are installed in support should be notified of potential problem.
the system.
14000101 14000101
14000081 14000081
Explanation: The voltage on voltage level 1 has
Explanation: The input power to BPA A has been lost reached the warning undervoltage limit for the
or partially lost. specified cage or drawer.
Failing Item:
v BPR-1A 14000102 14000102
v BPR-2A Explanation: The voltage on voltage level 2 has
v BPR-3A reached the warning undervoltage limit for the
v CBL-PWRC-BPE-A-PWR specified cage or drawer.
v BPC-A
v BPE-BOARD-A 14000103 14000103
Explanation: The voltage on voltage level 3 has
14000082 14000082 reached the warning undervoltage limit for the
specified cage or drawer.
Explanation: The input power to BPA B has been lost
or partially lost.
14000104 14000104
Failing Item:
Explanation: The voltage on voltage level 4 has
v BPR-1B
reached the warning undervoltage limit for the
v BPR-2B specified cage or drawer.
v BPR-3B
v CBL-PWRC-BPE-B-PWR 14000105 14000105
v BPC-B
Explanation: The voltage on voltage level 5 has
v BPE-BOARD-B reached the warning undervoltage limit for the
specified cage or drawer.
140000F0 140000F0
Explanation: The temperature sensed in a PU book 14000106 14000106
has reached a warning level. Next level of support Explanation: The voltage on voltage level 6 has
should be notified of potential problem. reached the warning undervoltage limit for the
specified cage or drawer.
140000F1 140000F1
Explanation: The temperature sensed in a PU book 14000107 14000107
has returned to normal from a warning level. Next Explanation: The voltage on voltage level 7 has
level of support should be notified of potential reached the warning undervoltage limit for the
problem. specified cage or drawer.
14000404 14000404
14001304 14001304
Explanation: An over voltage condition has been
detected for voltage level 4 for the specified cage or Explanation: This is a defective DASD on Backplane
drawer. one.
Explanation: An over voltage condition has been Explanation: This is a defective DASD on Backplane
detected for voltage level 5 for the specified cage or two.
drawer.
14001306 14001306
14000406 14000406 Explanation: This is a defective DASD on Backplane
Explanation: An over voltage condition has been three.
detected for voltage level 6 for the specified cage or
drawer. 14001307 14001307
Explanation: This is a defective DASD on Backplane
14000407 14000407 four.
Explanation: An over voltage condition has been
detected for voltage level 7 for the specified cage or 14001308 14001308
drawer.
Explanation: This is a switch riser card.
14000408 14000408
14001309 14001309
Explanation: An over voltage condition has been
detected for voltage level 8 specified cage or drawer. Explanation: This is a switch planer card.
v BPCA-PORT-4
14001A11 14001A11
Explanation: A communication fault between BPC A
14001A95 14001A95
and the load on port J01 has been detected.
Explanation: An over current has been detected on
Failing Item:
350V between BPC A and the load on its port J05.
v BPCA-PORT-1
Failing Item:
v BPCA-PORT-5
14001A14 14001A14
Explanation: A communication fault between BPC A
14001A96 14001A96
and the load on port J04 has been detected.
Explanation: An over current has been detected on
Failing Item:
350V between BPC A and the load on its port J06.
v BPCA-PORT-4
Failing Item:
v BPCA-PORT-6
14001A15 14001A15
Explanation: A communication fault between BPC A
14001A97 14001A97
and the load on port J05 has been detected.
Explanation: An over current has been detected on
Failing Item:
350V between BPC A and the load on its port J07.
v BPCA-PORT-5
Failing Item:
v BPCA-PORT-7
14001A16 14001A16
Explanation: A communication fault between BPC A
14001A98 14001A98
and the load on port J06 has been detected.
Explanation: An over current has been detected on
Failing Item:
350V between BPC A and the load on its port J08.
v BPCA-PORT-6
Failing Item:
v BPCA-PORT-8
14001A17 14001A17
Explanation: A communication fault between BPC A
14001A99 14001A99
and the load on port J07 has been detected.
Explanation: An over current has been detected on
Failing Item:
350V between BPC A and the load on its port J09.
v BPCA-PORT-7
Failing Item:
v BPCA-PORT-9
14001A18 14001A18
Explanation: A communication fault between BPC A
14001B11 14001B11
and the load on port J08 has been detected.
Explanation: A communication fault between BPC B
Failing Item:
and the load on port J01 has been detected.
v BPCA-PORT-8
Failing Item:
v BPCB-PORT-1
14001A19 14001A19
Explanation: A communication fault between BPC A
14001B14 14001B14
and the load on port J09 has been detected.
Explanation: A communication fault between BPC B
Failing Item:
and the load on port J04 has been detected.
v BPCA-PORT-9
Failing Item:
v BPCB-PORT-4
14001A94 14001A94
Explanation: An over current has been detected on
350V between BPC A and the load on its port J04.
Failing Item:
v BPCB-PORT-6
14001B15 14001B15
Explanation: A communication fault between BPC B
14001B97 14001B97
and the load on port J05 has been detected.
Explanation: An over current has been detected on
Failing Item:
350V between BPC B and the load on its port J07.
v BPCB-PORT-5
Failing Item:
v BPCB-PORT-7
14001B16 14001B16
Explanation: A communication fault between BPC B
14001B98 14001B98
and the load on port J06 has been detected.
Explanation: An over current has been detected on
Failing Item:
350V between BPC B and the load on its port J08.
v BPCB-PORT-6
Failing Item:
v BPCB-PORT-8
14001B17 14001B17
Explanation: A communication fault between BPC B
14001B99 14001B99
and the load on port J07 has been detected.
Explanation: An over current has been detected on
Failing Item:
350V between BPC B and the load on its port J09.
v BPCB-PORT-7
Failing Item:
v BPCB-PORT-9
14001B18 14001B18
Explanation: A communication fault between BPC B
14002051 14002051
and the load on port J08 has been detected.
Explanation: DCA number one is defective.
Failing Item:
v BPCB-PORT-8 Failing Item:
v DCA-01
14001B19 14001B19
14002052 14002052
Explanation: A communication fault between BPC B
and the load on port J09 has been detected. Explanation: DCA number two is defective.
Failing Item: Failing Item:
v BPCB-PORT-9 v DCA-02
14001B96 14001B96
Explanation: An over current has been detected on
350V between BPC B and the load on its port J06.
Failing Item:
14002097 14002097
14002073 14002073
Explanation: BPD-1 is defective in BPA-A.
Explanation: BPR-1A located in BPA-A has reported
an 'Over Temperature' Make sure that the Air inlets are Failing Item:
not blocked / filler books installed in empty locations v BPD-1A
and no heat source is located near the BPR ASM. v BPC-A
Failing Item:
v BPR-1A 1400209A 1400209A
Explanation: Communication error btween BPC A and
14002074 14002074 BPR 1A.
Explanation: BPR-1B located in BPA-B has reported an Failing Item:
'Over Temperature' Make sure that the Air inlets are v BPR-1A
not blocked / filler books installed in empty locations
v BPC-A
and no heat source is located near the BPR ASM.
v BPE-BOARD-A
Failing Item:
v BPR-1B
v BPD-2A
1400209B 1400209B
v BPD-3A
Explanation: Communication error btween BPC A and
v IBF-2A
BPR 2A.
v BPE-BOARD-A
Failing Item:
v BPR-2A
140020A5 140020A5
v BPC-A
Explanation: BPR-1A has reported an over-current on
v BPE-BOARD-A
the 350VDC bulk.
Failing Item:
1400209C 1400209C
v BPR-1A
Explanation: Communication error btween BPC A and
v BPD-1A
BPR 3A.
v BPC-A
Failing Item:
v BPD-2A
v BPR-3A
v BPD-3A
v BPC-A
v BPR-2A
v BPE-BOARD-A
v BPR-3A
v BPE-BOARD-A
1400209D 1400209D
Explanation: Communication error btween BPC B and 140020A6 140020A6
BPR 1B.
Explanation: The BPC in BPA-B is defective.
Failing Item:
Failing Item:
v BPR-1B
v BPC-B
v BPC-B
v BPE-BOARD-B
140020A7 140020A7
v BPC-A
14002152 14002152
v BPD-2A
Explanation: DCA number two is defective.
v BPD-3A
v BPR-1A Failing Item:
v BPR-3A v DCA-12
v BPE-BOARD-A
14002153 14002153
140020B7 140020B7 Explanation: DCA number three is defective.
Explanation: BPD-3 is defective in BPA-A. Failing Item:
Failing Item: v DCA-13
v BPD-3A
v BPC-A 14002173 14002173
Explanation: BPR-2A located in BPA-A has reported
140020B9 140020B9 an 'Over Temperature' Make sure that the Air inlets are
not blocked / filler books installed in empty locations
Explanation: The EPO panel or the cable between and no heat source is located near the BPR ASM.
both BPCs and EPO panel is defective.
Failing Item:
Failing Item:
v BPR-2A
v EPO-SWITCH
v CBL-BPCA-EPO
14002174 14002174
v CBL-BPCB-EPO
Explanation: BPR-2B located in BPA-B has reported an
v BPC-A
'Over Temperature' Make sure that the Air inlets are
v BPC-B not blocked / filler books installed in empty locations
and no heat source is located near the BPR ASM.
140020C1 140020C1 Failing Item:
Explanation: The UEPO switch on the BPC A-side is v BPR-2B
defective or in the BYPASS posistion. Switch to the
NORMAL posistion.
14002193 14002193
Failing Item:
Explanation: BPA-B BPR-1 is defective.
v BPC-A
Failing Item:
v BPR-1B
140020C5 140020C5
v BPC-B
Explanation: BPR-3A has reported an over-current on
v BPD-1B
the 350VDC bulk.
v BPD-2B
Failing Item:
v BPD-3B
v BPR-3A
v IBF-1B
v BPD-1A
v BPE-BOARD-B
v BPC-A
v BPD-2A
14002195 14002195
v BPD-3A
Explanation: BPA-B has reported an over-current on
v BPR-1A
the 350VDC bulk.
v BPR-2A
Failing Item:
v BPE-BOARD-A
v BPR-1B
v BPD-1B
14002151 14002151
v BPC-B
Explanation: DCA number one is defective.
v BPD-2B
Failing Item: v BPD-3B
v DCA-11 v BPR-2B
v BPR-3B v BPR-1B
v BPE-BOARD-B v BPR-3B
v BPE-BOARD-B
14002197 14002197
Explanation: BPD-1 is defective in BPA-B. 140021B7 140021B7
14002274 14002274
14002A0B 14002A0B
Explanation: BPR-3B located in BPA-B has reported an
Explanation: A communication fault between the BPC
'Over Temperature' Make sure that the Air inlets are
(BPA-A) and BPD 2A has been detected.
not blocked / filler books installed in empty locations
and no heat source is located near the BPR ASM. Failing Item:
Failing Item: v BPD-2A
v BPR-3B v BPC-A
v BPE-BOARD-A
14002351 14002351
14002A0C 14002A0C
Explanation: DCA number one is defective.
Explanation: A communication fault between the BPC
Failing Item:
(BPA-A) and BPD 3A has been detected.
v DCA-31
Failing Item:
v BPD-3A
14002352 14002352
v BPC-A
Explanation: DCA number two is defective.
v BPE-BOARD-A
Failing Item:
v DCA-32 14002A10 14002A10
Explanation: A communication fault between the BPD
14002353 14002353 1A and the load on port J00 has been detected.
Explanation: DCA number three is defective. Failing Item:
Failing Item: v BPD1A-PORT-0
v DCA-33
14002A11 14002A11
140024A5 140024A5 Explanation: A communication fault between the BPD
Explanation: BPR-1B has reported an over-current on 1A and the load on port J01 has been detected.
the 350VDC bulk. Failing Item:
Failing Item: v BPD1A-PORT-1
v BPR-1B
v BPD-1B 14002A12 14002A12
v BPC-B Explanation: A communication fault between the BPD
v BPD-2B 1A and the load on port J02 has been detected.
v BPD-3B Failing Item:
v BPR-2B v BPD1A-PORT-2
v BPR-3B
v BPE-BOARD-B 14002A13 14002A13
Explanation: A communication fault between the BPD
1A and the load on port J03 has been detected.
Failing Item:
v BPD1A-PORT-3
14002A21 14002A21
Explanation: A communication fault between the BPD
14002A14 14002A14
2A and the load on port J01 has been detected.
Explanation: A communication fault between the BPD
Failing Item:
1A and the load on port J04 has been detected.
v BPD2A-PORT-0
Failing Item:
v BPD1A-PORT-4
14002A22 14002A22
Explanation: A communication fault between the BPD
14002A15 14002A15
2A and the load on port J02 has been detected.
Explanation: A communication fault between the BPD
Failing Item:
1A and the load on port J05 has been detected.
v BPD2A-PORT-2
Failing Item:
v BPD1A-PORT-5
14002A23 14002A23
Explanation: A communication fault between the BPD
14002A16 14002A16
2A and the load on port J03 has been detected.
Explanation: A communication fault between the BPD
Failing Item:
1A and the load on port J06 has been detected.
v BPD2A-PORT-3
Failing Item:
v BPD1A-PORT-6
14002A24 14002A24
Explanation: A communication fault between the BPD
14002A17 14002A17
2A and the load on port J04 has been detected.
Explanation: A communication fault between the BPD
Failing Item:
1A and the load on port J07 has been detected.
v BPD2A-PORT-4
Failing Item:
v BPD1A-PORT-7
14002A25 14002A25
Explanation: A communication fault between the BPD
14002A18 14002A18
2A and the load on port J05 has been detected.
Explanation: A communication fault between the BPD
Failing Item:
1A and the load on port J08 has been detected.
v BPD2A-PORT-5
Failing Item:
v BPD1A-PORT-8
14002A26 14002A26
Explanation: A communication fault between the BPD
14002A19 14002A19
2A and the load on port J06 has been detected.
Explanation: A communication fault between the BPD
Failing Item:
1A and the load on port J09 has been detected.
v BPD2A-PORT-6
Failing Item:
v BPD1A-PORT-9
14002A27 14002A27
Explanation: A communication fault between the BPD
14002A20 14002A20
2A and the load on port J07 has been detected.
Explanation: A communication fault between the BPD
Failing Item:
2A and the load on port J00 has been detected.
v BPD2A-PORT-7
Failing Item:
v BPD2A-PORT-0
14002A28 14002A28
Explanation: A communication fault between the BPD
2A and the load on port J08 has been detected.
Failing Item:
v BPD2A-PORT-8
14002A36 14002A36
Explanation: A communication fault between the BPD
14002A29 14002A29
3A and the load on port J06 has been detected.
Explanation: A communication fault between the BPD
Failing Item:
2A and the load on port J09 has been detected.
v BPD3A-PORT-6
Failing Item:
v BPD2A-PORT-9
14002A37 14002A37
Explanation: A communication fault between the BPD
14002A30 14002A30
3A and the load on port J07 has been detected.
Explanation: A communication fault between the BPD
Failing Item:
3A and the load on port J00 has been detected.
v BPD3A-PORT-7
Failing Item:
v BPD3A-PORT-0
14002A38 14002A38
Explanation: A communication fault between the BPD
14002A31 14002A31
3A and the load on port J08 has been detected.
Explanation: A communication fault between the BPD
Failing Item:
3A and the load on port J01 has been detected.
v BPD3A-PORT-8
Failing Item:
v BPD3A-PORT-1
14002A39 14002A39
Explanation: A communication fault between the BPD
14002A32 14002A32
3A and the load on port J08 has been detected.
Explanation: A communication fault between the BPD
Failing Item:
3A and the load on port J02 has been detected.
v BPD3A-PORT-9
Failing Item:
v BPD3A-PORT-2
14002A81 14002A81
Explanation: A communication fault between (BPA-A)
14002A33 14002A33
BPC and (BPA-B) BPC.
Explanation: A communication fault between the BPD
Failing Item:
3A and the load on port J03 has been detected.
v BPC-B
Failing Item:
v BPR-1B
v BPD3A-PORT-3
v BPC-A
v CBL-NET-BPCA-BPCB
14002A34 14002A34
Explanation: A communication fault between the BPD 14002A90 14002A90
3A and the load on port J04 has been detected.
Explanation: An over current has been detected on
Failing Item: 350V between BPD 1A and the load on its port J00.
v BPD3A-PORT-4
Failing Item:
v BPD1A-PORT-0
14002A35 14002A35
Explanation: A communication fault between the BPD 14002A91 14002A91
3A and the load on port J05 has been detected.
Explanation: An over current has been detected on
Failing Item: 350V between BPD 1A and the load on its port J01.
v BPD3A-PORT-5
Failing Item:
v BPD1A-PORT-1
v BPD1A-PORT-9
14002A92 14002A92
Explanation: An over current has been detected on
14002AA0 14002AA0
350V between BPD 1A and the load on its port J02.
Explanation: An over current has been detected on
Failing Item:
350V between BPD 2A and the load on its port J00.
v BPD1A-PORT-2
Failing Item:
v BPD2A-PORT-0
14002A93 14002A93
Explanation: An over current has been detected on
14002AA1 14002AA1
350V between BPD 1A and the load on its port J03.
Explanation: An over current has been detected on
Failing Item:
350V between BPD 2A and the load on its port J01.
v BPD1A-PORT-3
Failing Item:
v BPD2A-PORT-0
14002A94 14002A94
Explanation: An over current has been detected on
14002AA2 14002AA2
350V between BPD 1A and the load on its port J04.
Explanation: An over current has been detected on
Failing Item:
350V between BPD 2A and the load on its port J02.
v BPD1A-PORT-4
Failing Item:
v BPD2A-PORT-2
14002A95 14002A95
Explanation: An over current has been detected on
14002AA3 14002AA3
350V between BPD 1A and the load on its port J05.
Explanation: An over current has been detected on
Failing Item:
350V between BPD 2A and the load on its port J03.
v BPD1A-PORT-5
Failing Item:
v BPD2A-PORT-3
14002A96 14002A96
Explanation: An over current has been detected on
14002AA4 14002AA4
350V between BPD 1A and the load on its port J06.
Explanation: An over current has been detected on
Failing Item:
350V between BPD 2A and the load on its port J04.
v BPD1A-PORT-6
Failing Item:
v BPD2A-PORT-4
14002A97 14002A97
Explanation: An over current has been detected on
14002AA5 14002AA5
350V between BPD 1A and the load on its port J07.
Explanation: An over current has been detected on
Failing Item:
350V between BPD 2A and the load on its port J05.
v BPD1A-PORT-7
Failing Item:
v BPD2A-PORT-5
14002A98 14002A98
Explanation: An over current has been detected on
14002AA6 14002AA6
350V between BPD 1A and the load on its port J08.
Explanation: An over current has been detected on
Failing Item:
350V between BPD 2A and the load on its port J06.
v BPD1A-PORT-8
Failing Item:
v BPD2A-PORT-6
14002A99 14002A99
Explanation: An over current has been detected on
350V between BPD 1A and the load on its port J09.
Failing Item:
v BPD3A-PORT-4
14002AA7 14002AA7
Explanation: An over current has been detected on
14002AB5 14002AB5
350V between BPD 2A and the load on its port J07.
Explanation: An over current has been detected on
Failing Item:
350V between BPD 3A and the load on its port J05.
v BPD2A-PORT-7
Failing Item:
v BPD3A-PORT-5
14002AA8 14002AA8
Explanation: An over current has been detected on
14002AB6 14002AB6
350V between BPD 2A and the load on its port J08.
Explanation: An over current has been detected on
Failing Item:
350V between BPD 3A and the load on its port J06.
v BPD2A-PORT-8
Failing Item:
v BPD3A-PORT-6
14002AA9 14002AA9
Explanation: An over current has been detected on
14002AB7 14002AB7
350V between BPD 2A and the load on its port J08.
Explanation: An over current has been detected on
Failing Item:
350V between BPD 3A and the load on its port J07.
v BPD2A-PORT-9
Failing Item:
v BPD3A-PORT-7
14002AB0 14002AB0
Explanation: An over current has been detected on
14002AB8 14002AB8
350V between BPD 3A and the load on its port J00.
Explanation: An over current has been detected on
Failing Item:
350V between BPD 3A and the load on its port J08.
v BPD3A-PORT-0
Failing Item:
v BPD3A-PORT-8
14002AB1 14002AB1
Explanation: An over current has been detected on
14002AB9 14002AB9
350V between BPD 3A and the load on its port J01.
Explanation: An over current has been detected on
Failing Item:
350V between BPD 3A and the load on its port J09.
v BPD3A-PORT-1
Failing Item:
v BPD3A-PORT-9
14002AB2 14002AB2
Explanation: An over current has been detected on
14002B0A 14002B0A
350V between BPD 3A and the load on its port J02.
Explanation: A communication fault between the BPC
Failing Item:
(BPA-B) and BPD 1B has been detected.
v BPD3A-PORT-2
Failing Item:
v BPD-1B
14002AB3 14002AB3
v BPC-B
Explanation: An over current has been detected on
v BPE-BOARD-B
350V between BPD 3A and the load on its port J03.
Failing Item:
14002B0B 14002B0B
v BPD3A-PORT-3
Explanation: A communication fault between the BPC
(BPA-B) and BPD 2B has been detected.
14002AB4 14002AB4
Failing Item:
Explanation: An over current has been detected on
v BPD-2B
350V between BPD 3A and the load on its port J04.
v BPC-B
Failing Item:
v BPE-BOARD-B
v BPD2B-PORT-3
14002B31 14002B31
Explanation: A communication fault between the BPD
14002B24 14002B24
3B and the load on port J01 has been detected.
Explanation: A communication fault between the BPD
Failing Item:
2B and the load on port J04 has been detected.
v BPD3B-PORT-1
Failing Item:
v BPD2B-PORT-4
14002B32 14002B32
Explanation: A communication fault between the BPD
14002B25 14002B25
3B and the load on port J02 has been detected.
Explanation: A communication fault between the BPD
Failing Item:
2B and the load on port J05 has been detected.
v BPD3B-PORT-2
Failing Item:
v BPD2B-PORT-5
14002B33 14002B33
Explanation: A communication fault between the BPD
14002B26 14002B26
3B and the load on port J03 has been detected.
Explanation: A communication fault between the BPD
Failing Item:
2B and the load on port J06 has been detected.
v BPD3B-PORT-3
Failing Item:
v BPD2B-PORT-6
14002B34 14002B34
Explanation: A communication fault between the BPD
14002B27 14002B27
3B and the load on port J04 has been detected.
Explanation: A communication fault between the BPD
Failing Item:
2B and the load on port J07 has been detected.
v BPD3B-PORT-4
Failing Item:
v BPD2B-PORT-7
14002B35 14002B35
Explanation: A communication fault between the BPD
14002B28 14002B28
3B and the load on port J05 has been detected.
Explanation: A communication fault between the BPD
Failing Item:
2B and the load on port J08 has been detected.
v BPD3B-PORT-5
Failing Item:
v BPD2B-PORT-8
14002B36 14002B36
Explanation: A communication fault between the BPD
14002B29 14002B29
3B and the load on port J06 has been detected.
Explanation: A communication fault between the BPD
Failing Item:
2B and the load on port J09 has been detected.
v BPD3B-PORT-6
Failing Item:
v BPD2B-PORT-9
14002B37 14002B37
Explanation: A communication fault between the BPD
14002B30 14002B30
3B and the load on port J07 has been detected.
Explanation: A communication fault between the BPD
Failing Item:
3B and the load on port J00 has been detected.
v BPD3B-PORT-7
Failing Item:
v BPD3B-PORT-0
14002B38 14002B38
Explanation: A communication fault between the BPD
3B and the load on port J08 has been detected.
Failing Item:
v BPD3B-PORT-8
14002B95 14002B95
Explanation: An over current has been detected on
14002B39 14002B39
350V between BPD 1B and the load on its port J05.
Explanation: A communication fault between the BPD
Failing Item:
3B and the load on port J08 has been detected.
v BPD1B-PORT-5
Failing Item:
v BPD3B-PORT-9
14002B96 14002B96
Explanation: An over current has been detected on
14002B81 14002B81
350V between BPD 1B and the load on its port J06.
Explanation: A communication fault between (BPA-B)
Failing Item:
BPC and (BPA-A) BPC.
v BPD1B-PORT-6
Failing Item:
v BPC-A
14002B97 14002B97
v BPR-1A
Explanation: An over current has been detected on
v BPC-B
350V between BPD 1B and the load on its port J07.
v CBL-NET-BPCB-BPCA
Failing Item:
v BPD1B-PORT-7
14002B90 14002B90
Explanation: An over current has been detected on
14002B98 14002B98
350V between BPD 1B and the load on its port J00.
Explanation: An over current has been detected on
Failing Item:
350V between BPD 1B and the load on its port J08.
v BPD1B-PORT-0
Failing Item:
v BPD1B-PORT-8
14002B91 14002B91
Explanation: An over current has been detected on
14002B99 14002B99
350V between BPD 1B and the load on its port J01.
Explanation: An over current has been detected on
Failing Item:
350V between BPD 1B and the load on its port J09.
v BPD1B-PORT-1
Failing Item:
v BPD1B-PORT-9
14002B92 14002B92
Explanation: An over current has been detected on
14002BA0 14002BA0
350V between BPD 1B and the load on its port J02.
Explanation: An over current has been detected on
Failing Item:
350V between BPD 2B and the load on its port J00.
v BPD1B-PORT-2
Failing Item:
v BPD2B-PORT-0
14002B93 14002B93
Explanation: An over current has been detected on
14002BA1 14002BA1
350V between BPD 1B and the load on its port J03.
Explanation: An over current has been detected on
Failing Item:
350V between BPD 2B and the load on its port J01.
v BPD1B-PORT-3
Failing Item:
v BPD2B-PORT-1
14002B94 14002B94
Explanation: An over current has been detected on
14002BA2 14002BA2
350V between BPD 1B and the load on its port J04.
Explanation: An over current has been detected on
Failing Item:
350V between BPD 2B and the load on its port J02.
v BPD1B-PORT-4
Failing Item:
v BPD2B-PORT-2
14002BB0 14002BB0
Explanation: An over current has been detected on
14002BA3 14002BA3
350V between BPD 3B and the load on its port J00.
Explanation: An over current has been detected on
Failing Item:
350V between BPD 2B and the load on its port J03.
v BPD3B-PORT-0
Failing Item:
v BPD2B-PORT-3
14002BB1 14002BB1
Explanation: An over current has been detected on
14002BA4 14002BA4
350V between BPD 3B and the load on its port J01.
Explanation: An over current has been detected on
Failing Item:
350V between BPD 2B and the load on its port J04.
v BPD3B-PORT-1
Failing Item:
v BPD2B-PORT-4
14002BB2 14002BB2
Explanation: An over current has been detected on
14002BA5 14002BA5
350V between BPD 3B and the load on its port J02.
Explanation: An over current has been detected on
Failing Item:
350V between BPD 2B and the load on its port J05.
v BPD3B-PORT-2
Failing Item:
v BPD2B-PORT-5
14002BB3 14002BB3
Explanation: An over current has been detected on
14002BA6 14002BA6
350V between BPD 3B and the load on its port J03.
Explanation: An over current has been detected on
Failing Item:
350V between BPD 2B and the load on its port J06.
v BPD3B-PORT-3
Failing Item:
v BPD2B-PORT-6
14002BB4 14002BB4
Explanation: An over current has been detected on
14002BA7 14002BA7
350V between BPD 3B and the load on its port J04.
Explanation: An over current has been detected on
Failing Item:
350V between BPD 2B and the load on its port J07.
v BPD3B-PORT-4
Failing Item:
v BPD2B-PORT-7
14002BB5 14002BB5
Explanation: An over current has been detected on
14002BA8 14002BA8
350V between BPD 3A and the load on its port J05.
Explanation: An over current has been detected on
Failing Item:
350V between BPD 2B and the load on its port J08.
v BPD3B-PORT-5
Failing Item:
v BPD2B-PORT-8
14002BB6 14002BB6
Explanation: An over current has been detected on
14002BA9 14002BA9
350V between BPD 3B and the load on its port J06.
Explanation: An over current has been detected on
Failing Item:
350V between BPD 2B and the load on its port J09.
v BPD3B-PORT-6
Failing Item:
v BPD2B-PORT-9
14002BB7 14002BB7
Explanation: An over current has been detected on
350V between BPD 3B and the load on its port J07.
Failing Item:
v BPD3B-PORT-7 v BPR-1B
v CBL-IBF1B
14002BB8 14002BB8 v BPC-B
Explanation: An over current has been detected on v BPE-BOARD-B
350V between BPD 3B and the load on its port J08.
Failing Item: 14003018 14003018
v BPD3B-PORT-8 Explanation: BPC-A side detects that IBF-1A is
disconnected. (IBF is connected to BPA-A BPR-1A)
14002BB9 14002BB9 Failing Item:
Explanation: An over current has been detected on v BPR-1A
350V between BPD 3B and the load on its port J09. v IBF-1A
Failing Item: v CBL-IBF1A
v BPD3B-PORT-9 v BPC-A
v BPE-BOARD-A
14003000 14003000
14003019 14003019
Explanation: BPC A side has detected unmatched
FRUs in the same CageID. Check P/Ns and codelevel Explanation: BPC-B side detects that IBF-1B is
of the Power FRUs in the cage. disconnected. (IBF is connected to BPA-B BPR-1B)
Failing Item:
14003005 14003005 v BPR-1B
Explanation: BPC A side has detected miscabling to v IBF-1B
DCA port. Correct cabling error. v CBL-IBF1B
v BPC-B
14003006 14003006 v BPE-BOARD-B
Explanation: BPC A side detects cabling order to a
DCA different than to the other DCAs (This BPA sides 1400301A 1400301A
view). Check and correct cable plugging.
Explanation: BPA-A side detects that IBF-1A has
dropped below a usable level. The system may power
14003007 14003007 off soon. The IBF will be charged after power is
Explanation: BPC A side detects cabling order to a restored. (IBF is connected to BPA-A BPR-1A)
MDA different than to the other MDAs (This BPA sides Failing Item:
view). Check and correct cable plugging.
v IBF-1A
v BPR-1A
14003014 14003014
v BPC-A
Explanation: BPC-A side detects that IBF-1A is v BPE-BOARD-A
defective. (IBF is connected to BPA-A BPR-1A)
Failing Item: 1400301B 1400301B
v IBF-1A
Explanation: BPA-B side detects that IBF-1B has
v BPR-1A dropped below a usable level. The system may power
v CBL-IBF1A off soon. The IBF will be charged after power is
v BPC-A restored. (IBF is connected to BPA-B BPR-1B)
v BPE-BOARD-A Failing Item:
v IBF-1B
14003015 14003015 v BPR-1B
Explanation: BPC-B side detects that IBF-1B is v BPC-B
defective. (IBF is connected to BPA-B BPR-1B) v BPE-BOARD-B
Failing Item:
v IBF-1B
v BPR-2B
1400301C 1400301C
v CBL-IBF2B
Explanation: BPA-A side detects that IBF-1A has been
v BPC-B
charged to normal capcity. The IBF is available to again
to provide power. (IBF is connected to BPA-A BPR-1A) v BPE-BOARD-B
Failing Item:
14003118 14003118
v IBF-1A
Explanation: BPC-A side detects that IBF-2A is
disconnected. (IBF is connected to BPA-A BPR-2A)
1400301D 1400301D
Failing Item:
Explanation: BPA-B side detects that IBF-1B has been
charged to normal capcity. The IBF is available to again v BPR-2A
to provide power. (IBF is connected to BPA-B BPR-1B) v IBF-2A
Failing Item: v CBL-IBF2A
v IBF-1B v BPC-A
v BPE-BOARD-A
14003090 14003090
14003119 14003119
Explanation: BPC B side has detected unmatched
FRUs in the same CageID. Check P/Ns and codelevel Explanation: BPC-B side detects that IBF-2B is
of the Power FRUs in the cage. disconnected. (IBF is connected to BPA-B BPR-2B)
Failing Item:
14003095 14003095 v BPR-2B
Explanation: BPC B side has detected miscabling to v IBF-2B
DCA port. Correct cabling error. v CBL-IBF2B
v BPC-B
14003096 14003096 v BPE-BOARD-B
Explanation: BPC B side detects cabling order to a
DCA different than to the other DCAs (This BPA sides 1400311A 1400311A
view). Check and correct cable plugging.
Explanation: BPA-A side detects that IBF-2A has
dropped below a usable level. The system may power
14003097 14003097 off soon. The IBF will be charged after power is
Explanation: BPC A side detects cabling order to a restored. (IBF is connected to BPA-A BPR-2A)
MDA different than to the other MDAs (This BPA sides Failing Item:
view). Check and correct cable plugging.
v IBF-2A
v BPR-2A
14003114 14003114
v BPC-A
Explanation: BPC-A side detects that IBF-2A is v BPE-BOARD-A
defective. (IBF is connected to BPA-A BPR-2A)
Failing Item: 1400311B 1400311B
v IBF-2A
Explanation: BPA-A side detects that IBF-2A has
v BPR-2A dropped below a usable level. The system may power
v CBL-IBF2A off soon. The IBF will be charged after power is
v BPC-A restored. (IBF is connected to BPA-A BPR-2A)
v BPE-BOARD-A Failing Item:
v IBF-2B
14003115 14003115 v BPR-2B
Explanation: BPC-B side detects that IBF-2B is v BPC-B
defective. (IBF is connected to BPA-B BPR-2B) v BPE-BOARD-B
Failing Item:
v IBF-2B
Failing Item:
v NOT_A_BPA_FRU
14004005 14004005
Explanation: A DHCP address was not assigned on
Network A. Contact next level of support for
assistance.
Failing Item:
v NOT_A_BPA_FRU
14008130 14008130
Explanation: CAGE P/T Fru recovery. Cage in power
recovery mode for information only.
14008131 14008131
Explanation: The UEPO switch has been used-This is
an informational SRC.
Failing Item:
v NOT_A_BPA_FRU
Note: Serviceable actions for the following SRCs require that you use the Service
focal point application on the HMC to access more specific information, including
isolation procedures, MAPs, and instruction on how to remove and replace parts.
Explanation: Air Moving Device number one is Explanation: The ambient room temperature is out of
defective. specification (to cold). The sensors are located in the
EPO panel and read/converted by the BPC.
Failing Item:
Failing Item:
v MDAA-1
v NOT_A_BPA_FRU
v MSAA-1
14010074 14010074
14010061 14010061
Explanation: The chilled input water to MWU1 is out
Explanation: Air Moving Device number two is
of specification (to cold) or there is an issue with flow.
defective.
If unable to correct contact IBM support.
Failing Item:
Failing Item:
v MDAA-2
v NOT_A_BPA_FRU
v MSAA-2
14010075 14010075
14010062 14010062
Explanation: The chilled input water to MWU2 is out
Explanation: Air Moving Device number three is of specification (to cold) or there is an issue with flow.
defective. If unable to correct contact IBM support.
Failing Item: Failing Item:
v MDAA-3 v NOT_A_BPA_FRU
v MSAA-3
1401007A 1401007A
14010081 14010081
Explanation: A fault has been detected on MCM1 in
the PU book indicated in failure information. See Explanation: Input power to BPA A has been lost or
Power fault reason code for further information and partially lost.
contact next level of support. Failing Item:
Failing Item: v BPR-1A
v MCM1 v BPR-2A
v BPR-3A
1401007B 1401007B v CBL-PWRC-BPE-A1-PWR
Explanation: A fault has been detected on MCM2 in v BPC-A
the PU book indicated in failure information. See v BPE-BOARD-A
Power fault reason code for further information and
contact next level of support.
14010082 14010082
Failing Item:
Explanation: The input power to BPA B has been lost
v MCM2 or partially lost.
Failing Item:
1401007C 1401007C
v BPR-1B
Explanation: A fault has been detected on MCM3 in v BPR-2B
the PU book indicated in failure information. See
v BPR-3B
Power fault reason code for further information and
contact next level of support. v CBL-PWRC-BPE-B1-PWR
v BPC-B
Failing Item:
v BPE-BOARD-B
v MCM3
v NOT_A_BPA_FRU
14010126 14010126
Explanation: The voltage on voltage level 26 has
14010136 14010136
reached the warning undervoltage limit for the
specified cage or drawer. Explanation: A PU book has entered throttling mode.
14010163 14010163
14010148 14010148
Explanation: DCA 2's Air Moving Device number one
Explanation: The voltage on voltage level 48 has
is defective.
reached the warning undervoltage limit for the
specified cage or drawer. Failing Item:
v MSAA-4
14010149 14010149 v IO_DCA-01
Explanation: The voltage on voltage level 49 has v IO_DCA-02
reached the warning undervoltage limit for the v MIDPLANE
specified cage or drawer.
14010164 14010164
14010150 14010150
Explanation: DCA 2's Air Moving Device number two
Explanation: The voltage on voltage level 35 has is defective.
reached the warning undervoltage limit for the
specified cage or drawer. Failing Item:
v MSAA-5
14010151 14010151 v IO_DCA-01
v IO_DCA-02
Explanation: The voltage on voltage level 36 has
reached the warning undervoltage limit for the v MIDPLANE
specified cage or drawer.
14010165 14010165
14010160 14010160 Explanation: DCA 2's Air Moving Device number
Explanation: DCA 1's Air Moving Device number one three is defective.
is defective. Failing Item:
Failing Item: v MSAA-6
v MSAA-1 v IO_DCA-01
v IO_DCA-01 v IO_DCA-02
v IO_DCA-02 v MIDPLANE
v MIDPLANE
14010200 14010200
14010161 14010161 Explanation: The voltage on voltage level 0 has
Explanation: DCA 1's Air Moving Device number two reached the warning over voltage limit for the specified
is defective. cage or drawer.
Failing Item:
14010201 14010201
v MSAA-2
v IO_DCA-01 Explanation: The voltage on voltage level 1 has
reached the warning over voltage limit for the specified
v IO_DCA-02 cage or drawer.
v MIDPLANE
14010262 14010262
14010244 14010244
Explanation: DCA 1's Air Moving Device number
Explanation: The voltage on voltage level 44 has
three is defective.
reached the warning over voltage limit for the specified
cage or drawer. Failing Item:
v MSAA-3
14010245 14010245 v IO_DCA-02
Explanation: The voltage on voltage level 45 has v IO_DCA-01
reached the warning over voltage limit for the specified v MIDPLANE
cage or drawer.
14010263 14010263
14010246 14010246
Explanation: DCA 2's Air Moving Device number one
Explanation: The voltage on voltage level 46 has is defective.
reached the warning over voltage limit for the specified
cage or drawer. Failing Item:
v MSAA-4
14010247 14010247 v IO_DCA-02
v IO_DCA-01
Explanation: The voltage on voltage level 47 has
reached the warning over voltage limit for the specified v MIDPLANE
cage or drawer.
14010264 14010264
14010248 14010248 Explanation: DCA 2's Air Moving Device number two
Explanation: The voltage on voltage level 48 has is defective.
reached the warning over voltage limit for the specified Failing Item:
cage or drawer.
v MSAA-5
v IO_DCA-02
14010249 14010249
v IO_DCA-01
Explanation: The voltage on voltage level 49 has v MIDPLANE
reached the warning over voltage limit for the specified
cage or drawer.
14010265 14010265
Explanation: An over current condition has been Explanation: DCA 2's Air Moving Device number one
detected for voltage level 43 for the specified cage or is defective.
drawer. Failing Item:
v MSAA-2
14010344 14010344 v IO_DCA-01
Explanation: An over current condition has been
detected for voltage level 44 for the specified cage or 14010362 14010362
drawer.
Explanation: DCA 1's Air Moving Device number
three is defective.
14010345 14010345
Failing Item:
Explanation: An over current condition has been
detected for voltage level 45 for the specified cage or v MSAA-3
drawer. v IO_DCA-01
Explanation: An over current condition has been Explanation: DCA 2's Air Moving Device number one
detected for voltage level 46 for the specified cage or is defective.
drawer.
Failing Item:
v MSAA-4
14010347 14010347
v IO_DCA-02
Explanation: An over current condition has been
detected for voltage level 47 for the specified cage or
14010364 14010364
drawer.
Explanation: DCA 2's Air Moving Device number two
is defective.
14010348 14010348
Failing Item:
Explanation: An over current condition has been
detected for voltage level 48 for the specified cage or v MSAA-5
drawer. v IO_DCA-02
Failing Item:
v FRULEVEL48 14010365 14010365
Explanation: DCA 2's Air Moving Device number
three is defective.
Failing Item:
v MSAA-6
14010409 14010409
v IO_DCA-02
Explanation: An over voltage condition has been
detected for voltage level 9 specified cage or drawer.
14010400 14010400
Explanation: An over voltage condition has been 14010410 14010410
detected for voltage level 0 for the specified cage or
drawer. Explanation: An over voltage condition has been
detected for voltage level 10 specified cage or drawer.
14010401 14010401
14010411 14010411
Explanation: An over voltage condition has been
detected for voltage level 1 for the specified cage or Explanation: An over voltage condition has been
drawer. detected for voltage level 11 specified cage or drawer.
Explanation: An over voltage condition has been Explanation: An over voltage condition has been
detected for voltage level 2 for the specified cage or detected for voltage level 12 specified cage or drawer.
drawer.
14010413 14010413
14010403 14010403 Explanation: An over voltage condition has been
Explanation: An over voltage condition has been detected for voltage level 13 specified cage or drawer.
detected for voltage level 3 for the specified cage or
drawer. 14010414 14010414
Explanation: An over voltage condition has been
14010404 14010404 detected for voltage level 14 for the specified cage or
Explanation: An over voltage condition has been drawer.
detected for voltage level 4 for the specified cage or
drawer. 14010415 14010415
Explanation: An over voltage condition has been
14010405 14010405 detected for voltage level 15 for the specified cage or
Explanation: An over voltage condition has been drawer.
detected for voltage level 5 for the specified cage or
drawer. 14010416 14010416
Explanation: An over voltage condition has been
14010406 14010406 detected for voltage level 16 for the specified cage or
Explanation: An over voltage condition has been drawer.
detected for voltage level 6 for the specified cage or
drawer. 14010417 14010417
Explanation: An over voltage condition has been
14010407 14010407 detected for voltage level 17 for the specified cage or
Explanation: An over voltage condition has been drawer.
detected for voltage level 7 for the specified cage or
drawer. 14010418 14010418
Explanation: An over voltage condition has been
14010408 14010408 detected for voltage level 18 specified cage or drawer.
Explanation: An over voltage condition has been
detected for voltage level 8 specified cage or drawer. 14010419 14010419
Explanation: An over voltage condition has been
detected for voltage level 19 specified cage or drawer.
Explanation: An over voltage condition has been Explanation: This is a defective DASD on Backplane
detected for voltage level 45 for the specified cage or one.
drawer.
14011305 14011305
14010446 14010446 Explanation: This is a defective DASD on Backplane
Explanation: An over voltage condition has been two.
detected for voltage level 46 for the specified cage or
drawer. 14011306 14011306
Explanation: This is a defective DASD on Backplane
14010447 14010447 three.
Explanation: An over voltage condition has been
detected for voltage level 47 for the specified cage or 14011307 14011307
drawer.
Explanation: This is a defective DASD on Backplane
four.
14010448 14010448
Explanation: An over voltage condition has been 14011308 14011308
detected for voltage level 48 specified cage or drawer.
Explanation: This is a switch riser card.
Failing Item:
v FRULEVEL48
14011309 14011309
v CONDUIT
1401130B 1401130B
v IO_DCA-02
Explanation: An error has been detected on the TRES
v IO_DCA-01
planar two.
v MIDPLANE
Failing Item:
v PLANAR2
14011311 14011311
v IO_DCA-01
Explanation: An error has been detected on the
v IO_DCA-02
conduit card.
v MIDPLANE
Failing Item:
v DASDBACKPLANE
1401130C 1401130C
Explanation: An error has been detected on the TRES
14011312 14011312
planar one.
Explanation: An error has been detected on the
Failing Item:
conduit card.
v PLANAR1
Failing Item:
v IO_DCA-02
v DASDBACKPLANE
v IO_DCA-01
v IO_DCA-01
v MIDPLANE
v IO_DCA-02
v MIDPLANE
1401130D 1401130D
v CONDUIT
Explanation: An error has been detected on the TRES
planar two.
14011313 14011313
Failing Item:
Explanation: An error has been detected on the
v PLANAR2
conduit card.
v IO_DCA-02
Failing Item:
v IO_DCA-01
v DASDBACKPLANE
v MIDPLANE
v IO_DCA-02
v IO_DCA-01
1401130E 1401130E
v MIDPLANE
Explanation: An error has been detected on the
v CONDUIT
conduit card.
Failing Item:
14011314 14011314
v CONDUIT
Explanation: An error has been detected on the
conduit card one.
1401130F 1401130F
Failing Item:
Explanation: An error has been detected on the
v PORTCARD1
conduit card.
Failing Item:
14011315 14011315
v CONDUIT
Explanation: An error has been detected on the
v IO_DCA-01
conduit card one.
v IO_DCA-02
Failing Item:
v MIDPLANE
v PORTCARD1
v IO_DCA-01
14011310 14011310
v IO_DCA-02
Explanation: An error has been detected on the
v MIDPLANE
conduit card.
v CONDUIT
Failing Item:
v DASDBACKPLANE
v CONDUIT
14012058 14012058
v DASDBACKPLANE
Explanation: A Plug ID error has been detected on
DCA1
14012051 14012051
Failing Item:
Explanation: DCA number one is defective.
v IO_DCA-01
Failing Item: v MIDPLANE
v IO_DCA-01
14012059 14012059
14012052 14012052
Explanation: A Plug ID error has been detected on
Explanation: DCA number two is defective. DCA2
Explanation: The bulk power fan is defective in Explanation: A defective TRES midplane has been
BPA-B. detected.
v EPO-SWITCH v BPCA-PORT-10-B
v CBL-BPCA-EPO
v CBL-BPCB-EPO 140121AC 140121AC
v BPC-A Explanation: A communication fault between BPC A
v BPC-B and the load on port J10 (C) has been detected.
Failing Item:
140120C1 140120C1 v BPCA-PORT-10-C
Explanation: The UEPO switch on the BPC A-side is
defective or in the BYPASS posistion. Switch to the 140121BB 140121BB
NORMAL posistion.
Explanation: A communication fault between BPC A
Failing Item: and the load on port J11 (B) has been detected.
v BPC-A
Failing Item:
v BPCA-PORT-11-B
140120C2 140120C2
Explanation: The BPC on the A-side has detected an 140121BC 140121BC
open UEPO loop.
Explanation: A communication fault between BPC A
Failing Item: and the load on port J11 (C) has been detected.
v EPO-SWITCH
Failing Item:
v BPC-A
v BPCA-PORT-11-C
v BPR-1A
v BPR-2A
140121C1 140121C1
v BPR-3A
Explanation: The UEPO switch on the BPC B-side is
v CBL-BPCA-EPO
defective or in the BYPASS posistion. Switch to the
v BPE-BOARD-A NORMAL posistion.
Failing Item:
1401218A 1401218A
v BPC-B
Explanation: A communication fault between BPC A
and the load on port J08 (A) has been detected.
140121C2 140121C2
Failing Item:
Explanation: The BPC on the B-side has detected an
v BPCA-PORT-08-A open UEPO loop.
Failing Item:
1401219A 1401219A
v EPO-SWITCH
Explanation: A communication fault between BPC A v BPC-B
and the load on port J09 (A) has been detected.
v BPR-1B
Failing Item: v BPR-2B
v BPCA-PORT-09-A v BPR-3B
v CBL-BPCB-EPO
140121AA 140121AA v BPE-BOARD-B
Explanation: A communication fault between BPC A
and the load on port J10 (A) has been detected. 1401221A 1401221A
Failing Item: Explanation: A communication fault between the BPD
v BPCA-PORT-10-A 1A and the load on port J01 (A) has been detected.
Failing Item:
140121AB 140121AB v BPD1A-PORT-01-A
Explanation: A communication fault between BPC A
and the load on port J10 (B) has been detected.
Failing Item:
v BPD1A-PORT-09-C
14012305 14012305
Explanation: A leak has been detectected on water
140122AA 140122AA
cooling system one.
Explanation: A communication fault between the BPD
Failing Item:
1A and the load on port J10 (A) has been detected.
v MWU-1
Failing Item:
v MDAW-1
v BPD1A-PORT-10-A
v MWU-2
v MDAW-2
140122AB 140122AB
Explanation: A communication fault between the BPD 14012306 14012306
1A and the load on port J10 (B) has been detected.
Explanation: A leak has been detectected on water
Failing Item: cooling system two.
v BPD1A-PORT-10-B
Failing Item:
v MWU-2
140122AC 140122AC
v MDAW-2
Explanation: A communication fault between the BPD v MWU-1
1A and the load on port J10 (C) has been detected.
v MDAW-1
Failing Item:
v BPD1A-PORT-10-C 14012307 14012307
Explanation: A valve problem has been detectected on
14012301 14012301 water cooling system one.
Explanation: Water cooling system one has failed to Failing Item:
adequately cool.
v MDAW-1
Failing Item: v MWU-VALVE-1
v MDAW-1
v MWU-1 14012308 14012308
Explanation: A valve problem has been detectected on
14012302 14012302 water cooling system two.
Explanation: Water cooling system two has failed to Failing Item:
adequately cool.
v MDAW-2
Failing Item: v MWU-VALVE-2
v MDAW-2
v MWU-2 14012309 14012309
Explanation: A Problem has been detectected on the
14012303 14012303 fill and drain tool.
Explanation: A problem with water supply has been Failing Item:
be detected on water cooling system one.
v MDA-FD-A
Failing Item: v FDT-A
v MDAW-1
v MWU-1 1401230A 1401230A
Explanation: A Problem has been detectected on the
14012304 14012304 fill and drain tool.
Explanation: A problem with water supply has been Failing Item:
be detected on water cooling system one.
v MDA-FD-B
Failing Item: v FDT-B
v MDAW-2
v MWU-2
v BPD2A-PORT-04-A
1401230B 1401230B
Explanation: A Problem has been detectected on the
14012351 14012351
fill and drain tool.
Explanation: DCA number one is defective.
Failing Item:
v FDT-A Failing Item:
v P3_CEC_DCA-01
1401230C 1401230C
14012352 14012352
Explanation: A Problem has been detectected on the
fill and drain tool. Explanation: DCA number two is defective.
Failing Item: Failing Item:
v FDT-B v P3-CEC-DCA_02
v BPD2A-PORT-08-A
140123AC 140123AC
Explanation: A communication fault between the BPD
1401238B 1401238B
2A and the load on port J10 (C) has been detected.
Explanation: A communication fault between the BPD
Failing Item:
2A and the load on port J08 (B) has been detected.
v BPD2A-PORT-10-C
Failing Item:
v BPD2A-PORT-08-B
1401241A 1401241A
Explanation: A communication fault between the BPD
1401238C 1401238C
3A and the load on port J01 (A) has been detected.
Explanation: A communication fault between the BPD
Failing Item:
2A and the load on port J08 (C) has been detected.
v BPD3A-PORT-01-A
Failing Item:
v BPD2A-PORT-08-C
1401242A 1401242A
Explanation: A communication fault between the BPD
1401239A 1401239A
3A and the load on port J02 (A) has been detected.
Explanation: A communication fault between the BPD
Failing Item:
2A and the load on port J09 (A) has been detected.
v BPD3A-PORT-02-A
Failing Item:
v BPD2A-PORT-09-A
1401243A 1401243A
Explanation: A communication fault between the BPD
1401239B 1401239B
3A and the load on port J03 (A) has been detected.
Explanation: A communication fault between the BPD
Failing Item:
2A and the load on port J09 (B) has been detected.
v BPD3A-PORT-03-A
Failing Item:
v BPD2A-PORT-09-B
1401244A 1401244A
Explanation: A communication fault between the BPD
1401239C 1401239C
3A and the load on port J04 (A) has been detected.
Explanation: A communication fault between the BPD
Failing Item:
2A and the load on port J09 (C) has been detected.
v BPD3A-PORT-04-A
Failing Item:
v BPD2A-PORT-09-C
14012451 14012451
Explanation: DCA number one is defective.
140123AA 140123AA
Failing Item:
Explanation: A communication fault between the BPD
2A and the load on port J10 (A) has been detected. v P4_CEC_DCA-01
Failing Item:
14012452 14012452
v BPD2A-PORT-10-A
Explanation: DCA number two is defective.
140123AB 140123AB Failing Item:
Explanation: A communication fault between the BPD v P4_CEC_DCA-02
2A and the load on port J10 (B) has been detected.
Failing Item: 14012551 14012551
v BPD2A-PORT-10-B Explanation: DCA number one is defective.
Failing Item:
v P5_CEC_DCA-01
Explanation: Communication error btween BPC A and Explanation: BPR-2A has reported an over-current on
BPR 6A. the 350VDC bulk.
Failing Item:
14012A13 14012A13
v BPCA-PORT-02
Explanation: BPR-3A has reported an over-current on
the 350VDC bulk.
14012A0C 14012A0C
Failing Item:
Explanation: Communication error btween BPC A and
BPH B. v BPR-3A
v BPD-1A
Failing Item:
v BPC-A
v BPCA-PORT-03
v BPD-2A
v BPR-1A
v BPR-2A
v BPE-BOARD-A
Failing Item:
14012A31 14012A31
v IBF-5A
Explanation: BPA-A side detects that IBF-1A has
v BPR-5A
dropped below a usable level. The system may power
off soon. The IBF will be charged after power is v BPC-A
restored. (IBF is connected to BPA-A BPR-1A) v BPE-BOARD-A
Failing Item:
v IBF-1A 14012A36 14012A36
v BPR-1A Explanation: BPA-A side detects that IBF-6A has
v BPC-A dropped below a usable level. The system may power
off soon. The IBF will be charged after power is
v BPE-BOARD-A
restored. (IBF is connected to BPA-A BPR-6A)
Failing Item:
14012A32 14012A32
v IBF-6A
Explanation: BPA-A side detects that IBF-2A has
v BPR-6A
dropped below a usable level. The system may power
off soon. The IBF will be charged after power is v BPC-A
restored. (IBF is connected to BPA-A BPR-2A) v BPE-BOARD-A
Failing Item:
v IBF-2A 14012A41 14012A41
v BPR-2A Explanation: BPA-A side detects that IBF-1A has been
v BPC-A charged to normal capcity. The IBF is available to again
to provide power. (IBF is connected to BPA-A BPR-1A)
v BPE-BOARD-A
Failing Item:
14012A33 14012A33 v IBF-1A
v BPD-1B
14012B08 14012B08
v BPC-B
Explanation: Communication error btween BPC B and
v BPE-BOARD-B
BPR 4B.
Failing Item:
14012B03 14012B03
v BPR-4B
Explanation: A communication fault between the BPC
v BPC-B
(BPA-B) and BPD 2B has been detected.
v BPE-BOARD-B
Failing Item:
v BPD-2B
14012B09 14012B09
v BPC-B
Explanation: Communication error btween BPC B and
v BPE-BOARD-B
BPR 5B.
Failing Item:
14012B04 14012B04
v BPR-5B
Explanation: A communication fault between the BPC
v BPC-B
(BPA-B) and BPD 3B has been detected.
v BPE-BOARD-B
Failing Item:
v BPD-3B
14012B0A 14012B0A
v BPC-B
Explanation: Communication error btween BPC B and
v BPE-BOARD-B
BPR 6B.
Failing Item:
14012B05 14012B05
v BPR-6B
Explanation: Communication error btween BPC B and
v BPC-B
BPR 1B.
v BPE-BOARD-B
Failing Item:
v BPR-1B
14012B0B 14012B0B
v BPC-B
Explanation: Communication error btween BPC B and
v BPE-BOARD-B
BPH B.
Failing Item:
14012B06 14012B06
v BPCB-PORT-02
Explanation: Communication error btween BPC B and
BPR 2B.
14012B0C 14012B0C
Failing Item:
Explanation: Communication error btween BPC B and
v BPR-2B
BPH A.
v BPC-B
Failing Item:
v BPE-BOARD-B
v BPCB-PORT-03
14012B07 14012B07
14012B10 14012B10
Explanation: Communication error btween BPC B and
BPR 3B. Explanation: BPA-A has reported an over-current on
the 350VDC bulk.
Failing Item:
Failing Item:
v BPR-3B
v BPR-1A
v BPC-B
v BPD-1A
v BPE-BOARD-B
v BPC-A
v BPD-2A
v BPR-2A
v BPR-3A
v BPE-BOARD-A v BPR-6B
v BPE-BOARD-B
14012B11 14012B11
Explanation: BPR-1B has reported an over-current on 14012B15 14012B15
the 350VDC bulk. Explanation: BPR-5B has reported an over-current on
Failing Item: the 350VDC bulk.
v BPR-1B Failing Item:
v BPD-1B v BPR-5B
v BPC-B v BPD-1B
v BPD-2B v BPC-B
v BPR-2B v BPD-2B
v BPR-3B v BPR-4B
v BPE-BOARD-B v BPR-6B
v BPE-BOARD-B
14012B12 14012B12
Explanation: BPR-2B has reported an over-current on 14012B16 14012B16
the 350VDC bulk. Explanation: BPR-6B has reported an over-current on
Failing Item: the 350VDC bulk.
v BPR-2B Failing Item:
v BPD-1B v BPR-6B
v BPC-B v BPD-1B
v BPD-2B v BPC-B
v BPR-1B v BPD-2B
v BPR-3B v BPR-4B
v BPE-BOARD-B v BPR-5B
v BPE-BOARD-B
14012B13 14012B13
Explanation: BPR-3B has reported an over-current on 14012B20 14012B20
the 350VDC bulk. Explanation: A BPA has reported 'No airflow in cage' -
Failing Item: Make sure that there are no blocked or dirty air inlet or
filters. Verify that all unused logic positions are filled
v BPR-3B
with filler books and that the BPF on the A-side has a
v BPD-1B cover over it / BPF on B-side does not.
v BPC-B
Failing Item:
v BPD-2B
v NOT_A_BPA_FRU
v BPR-1B
v BPR-2B
14012B21 14012B21
v BPE-BOARD-B
Explanation: BPR-1B located in BPA-B has reported an
'Over Temperature' Make sure that the Air inlets are
14012B14 14012B14 not blocked / filler books installed in empty locations
Explanation: BPR-4A has reported an over-current on and no heat source is located near the BPR ASM.
the 350VDC bulk. Failing Item:
Failing Item: v BPR-1B
v BPR-4B
v BPD-1B 14012B22 14012B22
v BPC-B Explanation: BPR-2B located in BPA-B has reported an
v BPD-2B 'Over Temperature' Make sure that the Air inlets are
v BPR-5B not blocked / filler books installed in empty locations
and no heat source is located near the BPR ASM.
Failing Item:
14012B32 14012B32
v BPR-2B
Explanation: BPA-B side detects that IBF-2B has
dropped below a usable level. The system may power
14012B23 14012B23 off soon. The IBF will be charged after power is
Explanation: BPR-3B located in BPA-B has reported an restored. (IBF is connected to BPA-B BPR-2B)
'Over Temperature' Make sure that the Air inlets are Failing Item:
not blocked / filler books installed in empty locations
v IBF-2B
and no heat source is located near the BPR ASM.
v BPR-2B
Failing Item:
v BPC-B
v BPR-3B
v BPE-BOARD-B
14012B24 14012B24
14012B33 14012B33
Explanation: BPR-4B located in BPA-B has reported an
Explanation: BPA-B side detects that IBF-3B has
'Over Temperature' Make sure that the Air inlets are
dropped below a usable level. The system may power
not blocked / filler books installed in empty locations
off soon. The IBF will be charged after power is
and no heat source is located near the BPR ASM.
restored. (IBF is connected to BPA-B BPR-3B)
Failing Item:
Failing Item:
v BPR-4B
v IBF-3B
v BPR-3B
14012B25 14012B25
v BPC-B
Explanation: BPR-5B located in BPA-B has reported an v BPE-BOARD-B
'Over Temperature' Make sure that the Air inlets are
not blocked / filler books installed in empty locations
and no heat source is located near the BPR ASM. 14012B34 14012B34
Failing Item:
14012B51 14012B51
v IBF-6B
Explanation: BPC-B side detects that IBF-1B is
v BPR-6B
disconnected. (IBF is connected to BPA-B BPR-1B)
v BPC-B
Failing Item:
v BPE-BOARD-B
v BPR-1B
v IBF-1B
14012B41 14012B41
v CBL-IBF1B
Explanation: BPA-B side detects that IBF-1B has been
v BPC-B
charged to normal capcity. The IBF is available to again
to provide power. (IBF is connected to BPA-B BPR-1B) v BPE-BOARD-B
Failing Item:
14012B52 14012B52
v IBF-1B
Explanation: BPC-B side detects that IBF-2B is
disconnected. (IBF is connected to BPA-B BPR-2B)
14012B42 14012B42
Failing Item:
Explanation: BPA-B side detects that IBF-2B has been
charged to normal capcity. The IBF is available to again v BPR-2B
to provide power. (IBF is connected to BPA-B BPR-2B) v IBF-2B
Failing Item: v CBL-IBF2B
v IBF-2B v BPC-B
v BPE-BOARD-B
14012B43 14012B43
14012B53 14012B53
Explanation: BPA-B side detects that IBF-3B has been
charged to normal capcity. The IBF is available to again Explanation: BPC-B side detects that IBF-3B is
to provide power. (IBF is connected to BPA-B BPR-3B) disconnected. (IBF is connected to BPA-B BPR-3B)
Failing Item: Failing Item:
v IBF-3B v BPR-3B
v IBF-3B
14012B44 14012B44 v CBL-IBF3B
Explanation: BPA-B side detects that IBF-4B has been v BPC-B
charged to normal capcity. The IBF is available to again v BPE-BOARD-B
to provide power. (IBF is connected to BPA-B BPR-4B)
Failing Item: 14012B54 14012B54
v IBF-4B Explanation: BPC-B side detects that IBF-4B is
disconnected. (IBF is connected to BPA-B BPR-4B)
14012B45 14012B45 Failing Item:
Explanation: BPA-B side detects that IBF-5B has been v BPR-4B
charged to normal capcity. The IBF is available to again v IBF-4B
to provide power. (IBF is connected to BPA-B BPR-5B)
v CBL-IBF4B
Failing Item: v BPC-B
v IBF-5B v BPE-BOARD-B
v BPC-B
14013095 14013095
v BPE-BOARD-B
Explanation: BPC B side has detected miscabling to
DCA port. Correct cabling error.
14012B56 14012B56
Explanation: BPC-B side detects that IBF-6B is 14013096 14013096
disconnected. (IBF is connected to BPA-B BPR-6B)
Explanation: BPC B side detects cabling order to a
Failing Item: DCA different than to the other DCAs (This BPA sides
v BPR-6B view). Check and correct cable plugging.
v IBF-6B
v CBL-IBF6B 14013097 14013097
v BPC-B Explanation: BPC A side detects cabling order to a
v BPE-BOARD-B MDA different than to the other MDAs (This BPA sides
view). Check and correct cable plugging.
14012B85 14012B85
1401318A 1401318A
Explanation: The A-side BPC has detected that the
cross feed from the B-side has failed. Explanation: A communication fault between BPC B
and the load on port J08 (A) has been detected.
Failing Item:
v BPCB-PORT-07 Failing Item:
v BPCB-PORT-08-A
14012C51 14012C51
1401319A 1401319A
Explanation: DCA number one is defective.
Explanation: A communication fault between BPC B
Failing Item: and the load on port J09 (A) has been detected.
v IH_DCA-01
Failing Item:
v BPCB-PORT-09-A
14013000 14013000
Explanation: BPC A side has detected unmatched 140131AA 140131AA
FRUs in the same CageID. Check P/Ns and codelevel
of the Power FRUs in the cage. Explanation: A communication fault between BPC B
and the load on port J10 (A) has been detected.
14013005 14013005 Failing Item:
Explanation: BPC A side has detected miscabling to v BPCB-PORT-10-A
DCA port. Correct cabling error.
140131AB 140131AB
14013006 14013006 Explanation: A communication fault between BPC B
Explanation: BPC A side detects cabling order to a and the load on port J10 (B) has been detected.
DCA different than to the other DCAs (This BPA sides Failing Item:
view). Check and correct cable plugging.
v BPCB-PORT-10-B
14013007 14013007
140131AC 140131AC
Explanation: BPC A side detects cabling order to a
Explanation: A communication fault between BPC B
MDA different than to the other MDAs (This BPA sides
and the load on port J10 (C) has been detected.
view). Check and correct cable plugging.
Failing Item:
14013090 14013090 v BPCB-PORT-10-C
v BPD1B-PORT-06-A
140131BB 140131BB
Explanation: A communication fault between BPC B
1401327A 1401327A
and the load on port J11 (B) has been detected.
Explanation: A communication fault between the BPD
Failing Item:
1B and the load on port J07 (A) has been detected.
v BPCB-PORT-11-B
Failing Item:
v BPD1B-PORT-07-A
140131BC 140131BC
Explanation: A communication fault between BPC B
1401327B 1401327B
and the load on port J11 (C) has been detected.
Explanation: A communication fault between the BPD
Failing Item:
1B and the load on port J07 (B) has been detected.
v BPCB-PORT-11-C
Failing Item:
v BPD1B-PORT-07-B
1401321A 1401321A
Explanation: A communication fault between the BPD
1401327C 1401327C
1B and the load on port J01 has been detected (A).
Explanation: A communication fault between the BPD
Failing Item:
1B and the load on port J07 (C) has been detected.
v BPD1B-PORT-01-A
Failing Item:
v BPD1B-PORT-07-C
1401322A 1401322A
Explanation: A communication fault between the BPD
1401328A 1401328A
1B and the load on port J02 has been detected (A).
Explanation: A communication fault between the BPD
Failing Item:
1B and the load on port J08 (A) has been detected.
v BPD1B-PORT-02-A
Failing Item:
v BPD1B-PORT-08-A
1401323A 1401323A
Explanation: A communication fault between the BPD
1401328B 1401328B
1B and the load on port J03 has been detected (A).
Explanation: A communication fault between the BPD
Failing Item:
1B and the load on port J08 (B) has been detected.
v BPD1B-PORT-03-A
Failing Item:
v BPD1B-PORT-08-B
1401324A 1401324A
Explanation: A communication fault between the BPD
1401328C 1401328C
1B and the load on port J04 has been detected (A).
Explanation: A communication fault between the BPD
Failing Item:
1B and the load on port J08 (C) has been detected.
v BPD1B-PORT-04-A
Failing Item:
v BPD1B-PORT-08-C
1401325A 1401325A
Explanation: A communication fault between the BPD
1401329A 1401329A
1B and the load on port J05 (A) has been detected.
Explanation: A communication fault between the BPD
Failing Item:
1B and the load on port J09 (A) has been detected.
v BPD1B-PORT-05-A
Failing Item:
v BPD1B-PORT-09-A
1401326A 1401326A
Explanation: A communication fault between the BPD
1B and the load on port J06 (A) has been detected.
Failing Item:
v BPD2B-PORT-03-A
1401329B 1401329B
Explanation: A communication fault between the BPD
1401334A 1401334A
1B and the load on port J09 (B) has been detected.
Explanation: A communication fault between the BPD
Failing Item:
2B and the load on port J04 (A) has been detected.
v BPD1B-PORT-09-B
Failing Item:
v BPD2B-PORT-04-A
1401329C 1401329C
Explanation: A communication fault between the BPD
1401335A 1401335A
1B and the load on port J09 (C) has been detected.
Explanation: A communication fault between the BPD
Failing Item:
2B and the load on port J05 (A) has been detected.
v BPD1B-PORT-09-C
Failing Item:
v BPD2B-PORT-05-A
140132AA 140132AA
Explanation: A communication fault between the BPD
1401336A 1401336A
1B and the load on port J10 (A) has been detected.
Explanation: A communication fault between the BPD
Failing Item:
2B and the load on port J06 (A) has been detected.
v BPD1B-PORT-10-A
Failing Item:
v BPD2B-PORT-06-A
140132AB 140132AB
Explanation: A communication fault between the BPD
1401337A 1401337A
1B and the load on port J10 (B) has been detected.
Explanation: A communication fault between the BPD
Failing Item:
2B and the load on port J07 (A) has been detected.
v BPD1B-PORT-10-B
Failing Item:
v BPD2B-PORT-07-A
140132AC 140132AC
Explanation: A communication fault between the BPD
1401337B 1401337B
1B and the load on port J10 (C) has been detected.
Explanation: A communication fault between the BPD
Failing Item:
2B and the load on port J07 (B) has been detected.
v BPD1B-PORT-10-C
Failing Item:
v BPD2B-PORT-07-B
1401331A 1401331A
Explanation: A communication fault between the BPD
1401337C 1401337C
2B and the load on port J01 (A) has been detected.
Explanation: A communication fault between the BPD
Failing Item:
2B and the load on port J07 (C) has been detected.
v BPD2B-PORT-01-A
Failing Item:
v BPD2B-PORT-07-C
1401332A 1401332A
Explanation: A communication fault between the BPD
1401338A 1401338A
2B and the load on port J02 (A) has been detected.
Explanation: A communication fault between the BPD
Failing Item:
2B and the load on port J08 (A) has been detected.
v BPD2B-PORT-02-A
Failing Item:
v BPD2B-PORT-08-A
1401333A 1401333A
Explanation: A communication fault between the BPD
2B and the load on port J03 (A) has been detected.
Failing Item:
v BPD3B-PORT-01-A
1401338B 1401338B
Explanation: A communication fault between the BPD
1401342A 1401342A
2B and the load on port J08 (B) has been detected.
Explanation: A communication fault between the BPD
Failing Item:
3B and the load on port J02 (A) has been detected.
v BPD2B-PORT-08-B
Failing Item:
v BPD3B-PORT-02-A
1401338C 1401338C
Explanation: A communication fault between the BPD
1401343A 1401343A
2B and the load on port J08 (C) has been detected.
Explanation: A communication fault between the BPD
Failing Item:
3B and the load on port J03 (A) has been detected.
v BPD2B-PORT-08-C
Failing Item:
v BPD3B-PORT-03-A
1401339B 1401339B
Explanation: A communication fault between the BPD
1401344A 1401344A
2B and the load on port J09 (B) has been detected.
Explanation: A communication fault between the BPD
Failing Item:
3B and the load on port J04 (A) has been detected.
v BPD2B-PORT-09-B
Failing Item:
v BPD3B-PORT-04-A
1401339C 1401339C
Explanation: A communication fault between the BPD
14014001 14014001
2B and the load on port J09 (C) has been detected.
Explanation: The Auto-Code-Download (ACDL) of the
Failing Item:
power subsystem encountered an error. Contact next
v BPD2B-PORT-09-C level of support for assistance.
Failing Item:
140133AA 140133AA
v NOT_A_BPA_FRU
Explanation: A communication fault between the BPD
2B and the load on port J10 (A) has been detected.
14014002 14014002
Failing Item:
Explanation: The frame MTMS was not resolved by
v BPD2B-PORT-10-A HMC. Contact next level of support for assistance.
Failing Item:
140133AB 140133AB
v NOT_A_BPA_FRU
Explanation: A communication fault between the BPD
2B and the load on port J10 (B) has been detected.
14014003 14014003
Failing Item:
Explanation: The BPC has found duplicate Mailbox IP
v BPD2B-PORT-10-B addresses on Network A. Contact next level of support
for assistance.
140133AC 140133AC Failing Item:
Explanation: A communication fault between the BPD v NOT_A_BPA_FRU
2B and the load on port J10 (C) has been detected.
Failing Item: 14014004 14014004
v BPD2B-PORT-10-C Explanation: The BPC has found duplicate Mailbox IP
addresses on Network B. Contact next level of support
1401341A 1401341A for assistance.
v BPD1A-PORT-05-A
1401529A 1401529A
Explanation: An over current has been detected on
1401526A 1401526A
350V between BPD 1A and the load on its port J09 (A).
Explanation: An over current has been detected on
Failing Item:
350V between BPD 1A and the load on its port J06 (A).
v BPD1A-PORT-09-A
Failing Item:
v BPD1A-PORT-06-A
1401529B 1401529B
Explanation: An over current has been detected on
1401527A 1401527A
350V between BPD 1A and the load on its port J09 (B).
Explanation: An over current has been detected on
Failing Item:
350V between BPD 1A and the load on its port J07 (A).
v BPD1A-PORT-09-B
Failing Item:
v BPD1A-PORT-07-A
1401529C 1401529C
Explanation: An over current has been detected on
1401527B 1401527B
350V between BPD 1A and the load on its port J09 (C).
Explanation: An over current has been detected on
Failing Item:
350V between BPD 1A and the load on its port J07 (B).
v BPD1A-PORT-09-C
Failing Item:
v BPD1A-PORT-07-B
140152AA 140152AA
Explanation: An over current has been detected on
1401527C 1401527C
350V between BPD 1A and the load on its port J10 (A).
Explanation: An over current has been detected on
Failing Item:
350V between BPD 1A and the load on its port J07 (C).
v BPD1A-PORT-10-A
Failing Item:
v BPD1A-PORT-07-C
140152AB 140152AB
Explanation: An over current has been detected on
1401528A 1401528A
350V between BPD 1A and the load on its port J10 (B).
Explanation: An over current has been detected on
Failing Item:
350V between BPD 1A and the load on its port J08 (A).
v BPD1A-PORT-10-B
Failing Item:
v BPD1A-PORT-08-A
140152AC 140152AC
Explanation: An over current has been detected on
1401528B 1401528B
350V between BPD 1A and the load on its port J10 (C).
Explanation: An over current has been detected on
Failing Item:
350V between BPD 1A and the load on its port J08 (B).
v BPD1A-PORT-10-C
Failing Item:
v BPD1A-PORT-08-B
1401531A 1401531A
Explanation: An over current has been detected on
1401528C 1401528C
350V between BPD 2A and the load on its port J01 (A).
Explanation: An over current has been detected on
Failing Item:
350V between BPD 1A and the load on its port J08 (C).
v BPD2A-PORT-01-A
Failing Item:
v BPD1A-PORT-08-C
1401532A 1401532A
Explanation: An over current has been detected on
350V between BPD 2A and the load on its port J02 (A).
Failing Item:
v BPD2A-PORT-02-A
1401538A 1401538A
Explanation: An over current has been detected on
1401533A 1401533A
350V between BPD 2A and the load on its port J08 (A).
Explanation: An over current has been detected on
Failing Item:
350V between BPD 2A and the load on its port J03 (A).
v BPD2A-PORT-08-A
Failing Item:
v BPD2A-PORT-03-A
1401538B 1401538B
Explanation: An over current has been detected on
1401534A 1401534A
350V between BPD 2A and the load on its port J08 (B).
Explanation: An over current has been detected on
Failing Item:
350V between BPD 2A and the load on its port J04 (A).
v BPD2A-PORT-08-B
Failing Item:
v BPD2A-PORT-04-A
1401538C 1401538C
Explanation: An over current has been detected on
1401535A 1401535A
350V between BPD 2A and the load on its port J08 (C).
Explanation: An over current has been detected on
Failing Item:
350V between BPD 2A and the load on its port J05 (A).
v BPD2A-PORT-08-C
Failing Item:
v BPD2A-PORT-05-A
1401539A 1401539A
Explanation: An over current has been detected on
1401536A 1401536A
350V between BPD 2A and the load on its port J09 (A).
Explanation: An over current has been detected on
Failing Item:
350V between BPD 2A and the load on its port J06 (A).
v BPD2A-PORT-09-A
Failing Item:
v BPD2A-PORT-06-A
1401539B 1401539B
Explanation: An over current has been detected on
1401537A 1401537A
350V between BPD 2A and the load on its port J09 (B).
Explanation: An over current has been detected on
Failing Item:
350V between BPD 2A and the load on its port J07 (A).
v BPD2A-PORT-09-B
Failing Item:
v BPD2A-PORT-07-A
1401539C 1401539C
Explanation: An over current has been detected on
1401537B 1401537B
350V between BPD 2A and the load on its port J09 (C).
Explanation: An over current has been detected on
Failing Item:
350V between BPD 2A and the load on its port J07 (B).
v BPD2A-PORT-09-C
Failing Item:
v BPD2A-PORT-07-B
140153AA 140153AA
Explanation: An over current has been detected on
1401537C 1401537C
350V between BPD 2A and the load on its port J10 (A).
Explanation: An over current has been detected on
Failing Item:
350V between BPD 2A and the load on its port J07 (C).
v BPD2A-PORT-10-A
Failing Item:
v BPD2A-PORT-07-C
140153AB 140153AB
Explanation: An over current has been detected on
350V between BPD 2A and the load on its port J10 (B).
Failing Item:
v BPD2A-PORT-10-B
140161AA 140161AA
Explanation: An over current has been detected on
140153AC 140153AC
350V between BPC B and the load on its port J10 (B).
Explanation: An over current has been detected on
Failing Item:
350V between BPD 2A and the load on its port J10 (C).
v BPCB-PORT-10-A
Failing Item:
v BPD2A-PORT-10-C
140161AB 140161AB
Explanation: An over current has been detected on
1401541A 1401541A
350V between BPC B and the load on its port J10 (B).
Explanation: An over current has been detected on
Failing Item:
350V between BPD 3A and the load on its port J01 (A).
v BPCB-PORT-10-B
Failing Item:
v BPD3A-PORT-01-A
140161AC 140161AC
Explanation: An over current has been detected on
1401542A 1401542A
350V between BPC B and the load on its port J10 (C).
Explanation: An over current has been detected on
Failing Item:
350V between BPD 3A and the load on its port J02 (A).
v BPCB-PORT-10-C
Failing Item:
v BPD3A-PORT-02-A
140161BB 140161BB
Explanation: An over current has been detected on
1401543A 1401543A
350V between BPC B and the load on its port J11 (B).
Explanation: An over current has been detected on
Failing Item:
350V between BPD 3A and the load on its port J03 (A).
v BPCB-PORT-11-B
Failing Item:
v BPD3A-PORT-03-A
140161BC 140161BC
Explanation: An over current has been detected on
1401544A 1401544A
350V between BPC B and the load on its port J11 (C).
Explanation: An over current has been detected on
Failing Item:
350V between BPD 2A and the load on its port J04 (A).
v BPCB-PORT-11-C
Failing Item:
v BPD3A-PORT-04-A
1401621A 1401621A
Explanation: An over current has been detected on
1401618A 1401618A
350V between BPD 1B and the load on its port J01 (A).
Explanation: An over current has been detected on
Failing Item:
350V between BPC B and the load on its port J08 (A).
v BPD1B-PORT-01-A
Failing Item:
v BPCB-PORT-08-A
1401622A 1401622A
Explanation: An over current has been detected on
1401619A 1401619A
350V between BPD 1B and the load on its port J02 (A).
Explanation: An over current has been detected on
Failing Item:
350V between BPC B and the load on its port J09 (A).
v BPD1B-PORT-02-A
Failing Item:
v BPCB-PORT-09-A
1401623A 1401623A
Explanation: An over current has been detected on
350V between BPD 1B and the load on its port J03 (A).
Failing Item:
v BPD1B-PORT-03-A
1401628B 1401628B
Explanation: An over current has been detected on
1401624A 1401624A
350V between BPD 1B and the load on its port J08 (B).
Explanation: An over current has been detected on
Failing Item:
350V between BPD 1B and the load on its port J04 (A).
v BPD1B-PORT-08-B
Failing Item:
v BPD1B-PORT-04-A
1401628C 1401628C
Explanation: An over current has been detected on
1401625A 1401625A
350V between BPD 1B and the load on its port J08 (C).
Explanation: An over current has been detected on
Failing Item:
350V between BPD 1B and the load on its port J05 (A).
v BPD1B-PORT-08-C
Failing Item:
v BPD1B-PORT-05-A
1401629A 1401629A
Explanation: An over current has been detected on
1401626A 1401626A
350V between BPD 1B and the load on its port J09 (A).
Explanation: An over current has been detected on
Failing Item:
350V between BPD 1B and the load on its port J06 (A).
v BPD1B-PORT-09-A
Failing Item:
v BPD1B-PORT-06-A
1401629B 1401629B
Explanation: An over current has been detected on
1401627A 1401627A
350V between BPD 1B and the load on its port J09 (B).
Explanation: An over current has been detected on
Failing Item:
350V between BPD 1B and the load on its port J07 (A).
v BPD1B-PORT-09-B
Failing Item:
v BPD1B-PORT-07-A
1401629C 1401629C
Explanation: An over current has been detected on
1401627B 1401627B
350V between BPD 1B and the load on its port J09 (C).
Explanation: An over current has been detected on
Failing Item:
350V between BPD 1B and the load on its port J07 (B).
v BPD1B-PORT-09-C
Failing Item:
v BPD1B-PORT-07-B
140162AA 140162AA
Explanation: An over current has been detected on
1401627C 1401627C
350V between BPD 1B and the load on its port J10 (A).
Explanation: An over current has been detected on
Failing Item:
350V between BPD 1B and the load on its port J07 (C).
v BPD1B-PORT-10-A
Failing Item:
v BPD1B-PORT-07-C
140162AB 140162AB
Explanation: An over current has been detected on
1401628A 1401628A
350V between BPD 1B and the load on its port J10 (B).
Explanation: An over current has been detected on
Failing Item:
350V between BPD 1B and the load on its port J08 (A).
v BPD1B-PORT-10-B
Failing Item:
v BPD1B-PORT-08-A
140162AC 140162AC
Explanation: An over current has been detected on
350V between BPD 1B and the load on its port J10 (C).
Failing Item:
v BPD1B-PORT-10-C
1401637B 1401637B
Explanation: An over current has been detected on
1401631A 1401631A
350V between BPD 2B and the load on its port J07 (B).
Explanation: An over current has been detected on
Failing Item:
350V between BPD 2B and the load on its port J01 (A).
v BPD2B-PORT-07-B
Failing Item:
v BPD2B-PORT-01-A
1401637C 1401637C
Explanation: An over current has been detected on
1401632A 1401632A
350V between BPD 2B and the load on its port J07 (C).
Explanation: An over current has been detected on
Failing Item:
350V between BPD 2B and the load on its port J02 (A).
v BPD2B-PORT-07-C
Failing Item:
v BPD2B-PORT-02-A
1401638A 1401638A
Explanation: An over current has been detected on
1401633A 1401633A
350V between BPD 2B and the load on its port J08 (A).
Explanation: An over current has been detected on
Failing Item:
350V between BPD 2B and the load on its port J03 (A).
v BPD2B-PORT-08-A
Failing Item:
v BPD2B-PORT-03-A
1401638B 1401638B
Explanation: An over current has been detected on
1401634A 1401634A
350V between BPD 2B and the load on its port J07 (B).
Explanation: An over current has been detected on
Failing Item:
350V between BPD 2B and the load on its port J04 (A).
v BPD2B-PORT-08-B
Failing Item:
v BPD2B-PORT-04-A
1401638C 1401638C
Explanation: An over current has been detected on
1401635A 1401635A
350V between BPD 2B and the load on its port J07 (C).
Explanation: An over current has been detected on
Failing Item:
350V between BPD 2B and the load on its port J05 (A).
v BPD2B-PORT-08-C
Failing Item:
v BPD2B-PORT-05-A
1401639A 1401639A
Explanation: An over current has been detected on
1401636A 1401636A
350V between BPD 2B and the load on its port J09 (A).
Explanation: An over current has been detected on
Failing Item:
350V between BPD 2B and the load on its port J06 (A).
v BPD2B-PORT-09-A
Failing Item:
v BPD2B-PORT-06-A
1401639B 1401639B
Explanation: An over current has been detected on
1401637A 1401637A
350V between BPD 2B and the load on its port J09 (B).
Explanation: An over current has been detected on
Failing Item:
350V between BPD 2B and the load on its port J07 (A).
v BPD2B-PORT-09-B
Failing Item:
v BPD2B-PORT-07-A
1401639C 1401639C
Explanation: An over current has been detected on
350V between BPD 2B and the load on its port J07 (C).
Failing Item:
v BPD2B-PORT-09-C
14017091 14017091
Explanation: The BPC in BPA-A is defective.
140163AA 140163AA
Failing Item:
Explanation: An over current has been detected on
350V between BPD 2B and the load on its port J10 (A). v BPC-A
Failing Item:
14017092 14017092
v BPD2B-PORT-10-A
Explanation: BPD-1 is defective in BPA-A.
140163AB 140163AB Failing Item:
Explanation: An over current has been detected on v BPD-1A
350V between BPD 2B and the load on its port J07 (B). v BPC-A
Failing Item:
v BPD2B-PORT-10-B 14017093 14017093
Explanation: BPD-2 is defective in BPA-A.
140163AC 140163AC Failing Item:
Explanation: An over current has been detected on v BPD-2A
350V between BPD 2B and the load on its port J10 (C). v BPC-A
Failing Item:
v BPD2B-PORT-10-C 14017094 14017094
Explanation: BPD-3 is defective in BPA-A.
1401641A 1401641A
Failing Item:
Explanation: An over current has been detected on v BPD-3A
350V between BPD 3B and the load on its port J01 (A).
v BPC-A
Failing Item:
v BPD3B-PORT-01-A 14017095 14017095
Explanation: BPA-A BPR-1 is defective.
1401642A 1401642A
Failing Item:
Explanation: An over current has been detected on
v BPR-1A
350V between BPD 3B and the load on its port J02 (A).
v BPC-A
Failing Item:
v BPD-1A
v BPD3B-PORT-02-A
v BPD-2A
v IBF-1A
1401643A 1401643A
v BPE-BOARD-A
Explanation: An over current has been detected on
350V between BPD 3B and the load on its port J03 (A).
14017096 14017096
Failing Item:
Explanation: BPA-A BPR-2 is defective.
v BPD3B-PORT-03-A
Failing Item:
v BPR-2A
1401644A 1401644A
v BPC-A
Explanation: An over current has been detected on
v BPD-1A
350V between BPD 3B and the load on its port J04 (A).
v BPD-2A
Failing Item:
v IBF-2A
v BPD3B-PORT-04-A
v BPE-BOARD-A
Explanation: BPA-A BPR-4 is defective. Explanation: BPC-A side detects that IBF-2A is
defective. (IBF is connected to BPA-A BPR-2A)
Failing Item:
Failing Item:
v BPR-4A
v IBF-2A
v BPC-A
v BPR-2A
v BPD-1A
v CBL-IBF2A
v BPD-2A
v BPC-A
v BPE-BOARD-A
v BPE-BOARD-A
14017099 14017099
140170A3 140170A3
Explanation: BPA-A BPR-5 is defective.
Explanation: BPC-A side detects that IBF-3A is
Failing Item: defective. (IBF is connected to BPA-A BPR-3A)
v BPR-5A
Failing Item:
v BPC-A
v IBF-3A
v BPD-1A
v BPR-3A
v BPD-2A
v CBL-IBF3A
v BPE-BOARD-A
v BPC-A
v BPE-BOARD-A
1401709A 1401709A
Explanation: BPA-A BPR-6 is defective. 140170A4 140170A4
Failing Item: Explanation: BPC-A side detects that IBF-4A is
v BPR-6A defective. (IBF is connected to BPA-A BPR-4A)
v BPC-A Failing Item:
v BPD-1A v IBF-4A
v BPD-2A v BPR-4A
v BPE-BOARD-A v CBL-IBF4A
v BPC-A
1401709B 1401709B v BPE-BOARD-A
Explanation: BPA-A BPH is defective.
Failing Item: 140170A5 140170A5
v BPC-A
14017196 14017196
v BPE-BOARD-A
Explanation: BPA-B BPR-2 is defective.
Failing Item:
140171A6 140171A6
v IBF-1B
v BPR-1B Explanation: BPC-B side detects that IBF-6B is
defective. (IBF is connected to BPA-B BPR-6B)
v CBL-IBF1B
v BPC-B Failing Item:
v BPE-BOARD-B v IBF-6B
v BPR-6B
140171A2 140171A2 v CBL-IBF6B
v BPC-B
Explanation: BPC-B side detects that IBF-2B is
defective. (IBF is connected to BPA-B BPR-2B) v BPE-BOARD-B
Failing Item:
14018072 14018072
v IBF-2B
v BPR-2B Explanation: BPA-A has reported a temperature
warning in cage - Make sure that there are no
v CBL-IBF2B
blocked/dirty air inlet or filters. Verify that all unused
v BPC-B logic positions are filled with filler books and that the
v BPE-BOARD-B BPF on the A-side has a cover over it / BPF on B-side
does not.
140171A3 140171A3
14018073 14018073
Explanation: BPC-B side detects that IBF-3B is
defective. (IBF is connected to BPA-B BPR-3B) Explanation: BPA-B has reported a temperature
warning in cage - Make sure that there are no
Failing Item: blocked/dirty air inlet or filters. Verify that all unused
v IBF-3B logic positions are filled with filler books and that the
v BPR-3B BPF on the A-side has a cover over it / BPF on B-side
does not.
v CBL-IBF3B
v BPC-B
140180C3 140180C3
v BPE-BOARD-B
Explanation: A-side BPC detects that the room UEPO
is in bypass. Verify the room UEPO loop is enabled.
140171A4 140171A4
Failing Item:
Explanation: BPC-B side detects that IBF-4B is
defective. (IBF is connected to BPA-B BPR-4B) v EPO-SWITCH
v BPC-A
Failing Item:
v CBL-BPCA-EPO
v IBF-4B
v BPR-4B
14018130 14018130
v CBL-IBF4B
v BPC-B Explanation: CAGE P/T Fru recovery. Cage in power
recovery mode for information only.
v BPE-BOARD-B
v MDA-FD-B
14018131 14018131
Explanation: The UEPO switch has been used-This is
14019999 14019999
an informational SRC.
Explanation: A bulk power logg has been created by
Failing Item:
an external command to BPA. Most likely this came
v NOT_A_BPA_FRU from a support personal will investigating a problem. It
is not a problem by itself and is for information
14018132 14018132 collecting only.
14018133 14018133
Explanation: A TMS (60) was received - Informational
SRC.
Failing Item:
v NOT_A_BPA_FRU
14018134 14018134
Explanation: This contains an ACDL log -
Informational SRC.
Failing Item:
v NOT_A_BPA_FRU
14018135 14018135
Explanation: There has been an internal bulk power
software error. This is an informational reference code.
Failing Item:
v NOT_A_BPA_FRU
14018136 14018136
Explanation: A PU book has entered throttling mode.
This is an informational reference code.
140181C3 140181C3
Explanation: B-side BPC detects that the room UEPO
is in bypass. Verify the room UEPO loop is enabled.
Failing Item:
v EPO-SWITCH
v BPC-B
v CBL-BPCB-EPO
14018888 14018888
Explanation: Informational message: a DCA in a T24
drawer has recovered. No service action is required.
Failing Item:
Response: No action required. This reference code is Explanation: Device Licensed Internal Code
logged for information only. Response: The device is not supported with the level
of code currently on the system. Contact your next
169C3100 169C3100 level of support.
169CFFF4 169CFFF4
169C4060 169C4060
Explanation: Disk device problem
Explanation: Multipath redundancy level reduced
Failing Item:
Response: A redundant disk unit connection has
failed. v DISKDRV
v STORIOA
Failing Item:
v SIP3153
169CFFF5 169CFFF5
v SASCABL
v SASEXP Explanation: Disk sector read error
Response: If this event appears in a serviceable event
169C4061 169C4061 view, work with the failing item list found there. If this
event does not appear in a serviceable event view, no
Explanation: Multipath redundancy level increased service action is required.
Response: A redundant disk unit connection has been Failing Item:
restored. No service action is required.
v DISKDRV
169C4100 169C4100
169CFFF6 169CFFF6
Explanation: Device bus fabric error
Explanation: Disk device detected recoverable error
Failing Item:
Response: If this event appears in a serviceable event
v SIP3152 view, work with the failing item list found there. If this
v SASCABL event does not appear in a serviceable event view, no
v SASEXP service action is required.
169CFFFB 169CFFFB
Explanation: SAS bus reset occurred
Response: No action required. This reference code is
logged for information only.
169CFFFC 169CFFFC
Explanation: Soft device bus error.
Response: If this event appears in a serviceable event
view, work with the failing item list found there. If this
event does not appear in a serviceable event view, no
service action is required.
Failing Item:
v SIP3250
v DISKDRV
v STORIOA
169CFFFD 169CFFFD
Explanation: Soft device bus error.
Response: If this event appears in a serviceable event
view, work with the failing item list found there. If this
event does not appear in a serviceable event view, no
service action is required.
Failing Item:
v SIP3250
v DISKDRV
v STORIOA
1750FFF6 1750FFF6
Explanation: Disk device detected recoverable error
Response: If this event appears in a serviceable event
view, work with the failing item list found there. If this
event does not appear in a serviceable event view, no
service action is required.
Failing Item:
v FCDEV
1750FFFA 1750FFFA
Explanation: Disk device wrong response was
recovered by the IOP
Response: If this event appears in a serviceable event
view, work with the failing item list found there. If this
event does not appear in a serviceable event view, no
service action is required.
Failing Item:
v FCDEV
v FCIOA
v OPT_CLN
1750FFFE 1750FFFE
Explanation: Temporary Fibre Channel interface error.
Response: If this event appears in a serviceable event
view, work with the failing item list found there. If this
event does not appear in a serviceable event view, no
service action is required.
Failing Item:
v FCINTF
v FCDEV
v FCIOA
v OPT_CLN
Response: No action required. This reference code is Explanation: Device Licensed Internal Code
logged for information only. Response: The device is not supported with the level
of code currently on the system. Contact your next
198B3100 198B3100 level of support.
198BFFF4 198BFFF4
198B4060 198B4060
Explanation: Disk device problem
Explanation: Multipath redundancy level reduced
Failing Item:
Response: A redundant disk unit connection has
failed. v DISKDRV
v STORIOA
Failing Item:
v SIP3153
198BFFF5 198BFFF5
v SASCABL
v SASEXP Explanation: Disk sector read error
Response: If this event appears in a serviceable event
198B4061 198B4061 view, work with the failing item list found there. If this
event does not appear in a serviceable event view, no
Explanation: Multipath redundancy level increased service action is required.
Response: A redundant disk unit connection has been Failing Item:
restored. No service action is required.
v DISKDRV
198B4100 198B4100
198BFFF6 198BFFF6
Explanation: Device bus fabric error
Explanation: Disk device detected recoverable error
Failing Item:
Response: If this event appears in a serviceable event
v SIP3152 view, work with the failing item list found there. If this
v SASCABL event does not appear in a serviceable event view, no
v SASEXP service action is required.
198BFFFB 198BFFFB
Explanation: SAS bus reset occurred
Response: No action required. This reference code is
logged for information only.
198BFFFC 198BFFFC
Explanation: Soft device bus error.
Response: If this event appears in a serviceable event
view, work with the failing item list found there. If this
event does not appear in a serviceable event view, no
service action is required.
Failing Item:
v SIP3250
v DISKDRV
v STORIOA
198BFFFD 198BFFFD
Explanation: Soft device bus error.
Response: If this event appears in a serviceable event
view, work with the failing item list found there. If this
event does not appear in a serviceable event view, no
service action is required.
Failing Item:
v SIP3250
v DISKDRV
v STORIOA
Response: No action required. This reference code is Explanation: Device Licensed Internal Code
logged for information only. Response: The device is not supported with the level
of code currently on the system. Contact your next
198C3100 198C3100 level of support.
198CFFF4 198CFFF4
198C4060 198C4060
Explanation: Disk device problem
Explanation: Multipath redundancy level reduced
Failing Item:
Response: A redundant disk unit connection has
failed. v DISKDRV
v STORIOA
Failing Item:
v SIP3153
198CFFF5 198CFFF5
v SASCABL
v SASEXP Explanation: Disk sector read error
Response: If this event appears in a serviceable event
198C4061 198C4061 view, work with the failing item list found there. If this
event does not appear in a serviceable event view, no
Explanation: Multipath redundancy level increased service action is required.
Response: A redundant disk unit connection has been Failing Item:
restored. No service action is required.
v DISKDRV
198C4100 198C4100
198CFFF6 198CFFF6
Explanation: Device bus fabric error
Explanation: Disk device detected recoverable error
Failing Item:
Response: If this event appears in a serviceable event
v SIP3152 view, work with the failing item list found there. If this
v SASCABL event does not appear in a serviceable event view, no
v SASEXP service action is required.
198CFFFB 198CFFFB
Explanation: SAS bus reset occurred
Response: No action required. This reference code is
logged for information only.
198CFFFC 198CFFFC
Explanation: Soft device bus error.
Response: If this event appears in a serviceable event
view, work with the failing item list found there. If this
event does not appear in a serviceable event view, no
service action is required.
Failing Item:
v SIP3250
v DISKDRV
v STORIOA
198CFFFD 198CFFFD
Explanation: Soft device bus error.
Response: If this event appears in a serviceable event
view, work with the failing item list found there. If this
event does not appear in a serviceable event view, no
service action is required.
Failing Item:
v SIP3250
v DISKDRV
v STORIOA
Response: No action required. This reference code is Explanation: Device Licensed Internal Code
logged for information only. Response: The device is not supported with the level
of code currently on the system. Contact your next
198D3100 198D3100 level of support.
198DFFF4 198DFFF4
198D4060 198D4060
Explanation: Disk device problem
Explanation: Multipath redundancy level reduced
Failing Item:
Response: A redundant disk unit connection has
failed. v DISKDRV
v STORIOA
Failing Item:
v SIP3153
198DFFF5 198DFFF5
v SASCABL
v SASEXP Explanation: Disk sector read error
Response: If this event appears in a serviceable event
198D4061 198D4061 view, work with the failing item list found there. If this
event does not appear in a serviceable event view, no
Explanation: Multipath redundancy level increased service action is required.
Response: A redundant disk unit connection has been Failing Item:
restored. No service action is required.
v DISKDRV
198D4100 198D4100
198DFFF6 198DFFF6
Explanation: Device bus fabric error
Explanation: Disk device detected recoverable error
Failing Item:
Response: If this event appears in a serviceable event
v SIP3152 view, work with the failing item list found there. If this
v SASCABL event does not appear in a serviceable event view, no
v SASEXP service action is required.
198DFFFB 198DFFFB
Explanation: SAS bus reset occurred
Response: No action required. This reference code is
logged for information only.
198DFFFC 198DFFFC
Explanation: Soft device bus error.
Response: If this event appears in a serviceable event
view, work with the failing item list found there. If this
event does not appear in a serviceable event view, no
service action is required.
Failing Item:
v SIP3250
v DISKDRV
v STORIOA
198DFFFD 198DFFFD
Explanation: Soft device bus error.
Response: If this event appears in a serviceable event
view, work with the failing item list found there. If this
event does not appear in a serviceable event view, no
service action is required.
Failing Item:
v SIP3250
v DISKDRV
v STORIOA
Response: No action required. This reference code is Explanation: Device Licensed Internal Code
logged for information only. Response: The device is not supported with the level
of code currently on the system. Contact your next
198E3100 198E3100 level of support.
198EFFF4 198EFFF4
198E4060 198E4060
Explanation: Disk device problem
Explanation: Multipath redundancy level reduced
Failing Item:
Response: A redundant disk unit connection has
failed. v DISKDRV
v STORIOA
Failing Item:
v SIP3153
198EFFF5 198EFFF5
v SASCABL
v SASEXP Explanation: Disk sector read error
Response: If this event appears in a serviceable event
198E4061 198E4061 view, work with the failing item list found there. If this
event does not appear in a serviceable event view, no
Explanation: Multipath redundancy level increased service action is required.
Response: A redundant disk unit connection has been Failing Item:
restored. No service action is required.
v DISKDRV
198E4100 198E4100
198EFFF6 198EFFF6
Explanation: Device bus fabric error
Explanation: Disk device detected recoverable error
Failing Item:
Response: If this event appears in a serviceable event
v SIP3152 view, work with the failing item list found there. If this
v SASCABL event does not appear in a serviceable event view, no
v SASEXP service action is required.
198EFFFB 198EFFFB
Explanation: SAS bus reset occurred
Response: No action required. This reference code is
logged for information only.
198EFFFC 198EFFFC
Explanation: Soft device bus error.
Response: If this event appears in a serviceable event
view, work with the failing item list found there. If this
event does not appear in a serviceable event view, no
service action is required.
Failing Item:
v SIP3250
v DISKDRV
v STORIOA
198EFFFD 198EFFFD
Explanation: Soft device bus error.
Response: If this event appears in a serviceable event
view, work with the failing item list found there. If this
event does not appear in a serviceable event view, no
service action is required.
Failing Item:
v SIP3250
v DISKDRV
v STORIOA
Response: No action required. This reference code is Explanation: Device Licensed Internal Code
logged for information only. Response: The device is not supported with the level
of code currently on the system. Contact your next
19A13100 19A13100 level of support.
19A1FFF4 19A1FFF4
19A14060 19A14060
Explanation: Disk device problem
Explanation: Multipath redundancy level reduced
Failing Item:
Response: A redundant disk unit connection has
failed. v DISKDRV
v STORIOA
Failing Item:
v SIP3153
19A1FFF5 19A1FFF5
v SASCABL
v SASEXP Explanation: Disk sector read error
Response: If this event appears in a serviceable event
19A14061 19A14061 view, work with the failing item list found there. If this
event does not appear in a serviceable event view, no
Explanation: Multipath redundancy level increased service action is required.
Response: A redundant disk unit connection has been Failing Item:
restored. No service action is required.
v DISKDRV
19A14100 19A14100
19A1FFF6 19A1FFF6
Explanation: Device bus fabric error
Explanation: Disk device detected recoverable error
Failing Item:
Response: If this event appears in a serviceable event
v SIP3152 view, work with the failing item list found there. If this
v SASCABL event does not appear in a serviceable event view, no
v SASEXP service action is required.
19A1FFFB 19A1FFFB
Explanation: SAS bus reset occurred
Response: No action required. This reference code is
logged for information only.
19A1FFFC 19A1FFFC
Explanation: Soft device bus error.
Response: If this event appears in a serviceable event
view, work with the failing item list found there. If this
event does not appear in a serviceable event view, no
service action is required.
Failing Item:
v SIP3250
v DISKDRV
v STORIOA
19A1FFFD 19A1FFFD
Explanation: Soft device bus error.
Response: If this event appears in a serviceable event
view, work with the failing item list found there. If this
event does not appear in a serviceable event view, no
service action is required.
Failing Item:
v SIP3250
v DISKDRV
v STORIOA
Response: No action required. This reference code is Explanation: Device Licensed Internal Code
logged for information only. Response: The device is not supported with the level
of code currently on the system. Contact your next
19A33100 19A33100 level of support.
19A3FFF4 19A3FFF4
19A34060 19A34060
Explanation: Disk device problem
Explanation: Multipath redundancy level reduced
Failing Item:
Response: A redundant disk unit connection has
failed. v DISKDRV
v STORIOA
Failing Item:
v SIP3153
19A3FFF5 19A3FFF5
v SASCABL
v SASEXP Explanation: Disk sector read error
Response: If this event appears in a serviceable event
19A34061 19A34061 view, work with the failing item list found there. If this
event does not appear in a serviceable event view, no
Explanation: Multipath redundancy level increased service action is required.
Response: A redundant disk unit connection has been Failing Item:
restored. No service action is required.
v DISKDRV
19A34100 19A34100
19A3FFF6 19A3FFF6
Explanation: Device bus fabric error
Explanation: Disk device detected recoverable error
Failing Item:
Response: If this event appears in a serviceable event
v SIP3152 view, work with the failing item list found there. If this
v SASCABL event does not appear in a serviceable event view, no
v SASEXP service action is required.
19A3FFFB 19A3FFFB
Explanation: SAS bus reset occurred
Response: No action required. This reference code is
logged for information only.
19A3FFFC 19A3FFFC
Explanation: Soft device bus error.
Response: If this event appears in a serviceable event
view, work with the failing item list found there. If this
event does not appear in a serviceable event view, no
service action is required.
Failing Item:
v SIP3250
v DISKDRV
v STORIOA
19A3FFFD 19A3FFFD
Explanation: Soft device bus error.
Response: If this event appears in a serviceable event
view, work with the failing item list found there. If this
event does not appear in a serviceable event view, no
service action is required.
Failing Item:
v SIP3250
v DISKDRV
v STORIOA
Response: No action required. This reference code is Explanation: Device Licensed Internal Code
logged for information only. Response: The device is not supported with the level
of code currently on the system. Contact your next
19B03100 19B03100 level of support.
19B0FFF4 19B0FFF4
19B04060 19B04060
Explanation: Disk device problem
Explanation: Multipath redundancy level reduced
Failing Item:
Response: A redundant disk unit connection has
failed. v DISKDRV
v STORIOA
Failing Item:
v SIP3153
19B0FFF5 19B0FFF5
v SASCABL
v SASEXP Explanation: Disk sector read error
Response: If this event appears in a serviceable event
19B04061 19B04061 view, work with the failing item list found there. If this
event does not appear in a serviceable event view, no
Explanation: Multipath redundancy level increased service action is required.
Response: A redundant disk unit connection has been Failing Item:
restored. No service action is required.
v DISKDRV
19B04100 19B04100
19B0FFF6 19B0FFF6
Explanation: Device bus fabric error
Explanation: Disk device detected recoverable error
Failing Item:
Response: If this event appears in a serviceable event
v SIP3152 view, work with the failing item list found there. If this
v SASCABL event does not appear in a serviceable event view, no
v SASEXP service action is required.
19B0FFFB 19B0FFFB
Explanation: SAS bus reset occurred
Response: No action required. This reference code is
logged for information only.
19B0FFFC 19B0FFFC
Explanation: Soft device bus error.
Response: If this event appears in a serviceable event
view, work with the failing item list found there. If this
event does not appear in a serviceable event view, no
service action is required.
Failing Item:
v SIP3250
v DISKDRV
v STORIOA
19B0FFFD 19B0FFFD
Explanation: Soft device bus error.
Response: If this event appears in a serviceable event
view, work with the failing item list found there. If this
event does not appear in a serviceable event view, no
service action is required.
Failing Item:
v SIP3250
v DISKDRV
v STORIOA
Response: No action required. This reference code is Explanation: Device Licensed Internal Code
logged for information only. Response: The device is not supported with the level
of code currently on the system. Contact your next
19B13100 19B13100 level of support.
19B1FFF4 19B1FFF4
19B14060 19B14060
Explanation: Disk device problem
Explanation: Multipath redundancy level reduced
Failing Item:
Response: A redundant disk unit connection has
failed. v DISKDRV
v STORIOA
Failing Item:
v SIP3153
19B1FFF5 19B1FFF5
v SASCABL
v SASEXP Explanation: Disk sector read error
Response: If this event appears in a serviceable event
19B14061 19B14061 view, work with the failing item list found there. If this
event does not appear in a serviceable event view, no
Explanation: Multipath redundancy level increased service action is required.
Response: A redundant disk unit connection has been Failing Item:
restored. No service action is required.
v DISKDRV
19B14100 19B14100
19B1FFF6 19B1FFF6
Explanation: Device bus fabric error
Explanation: Disk device detected recoverable error
Failing Item:
Response: If this event appears in a serviceable event
v SIP3152 view, work with the failing item list found there. If this
v SASCABL event does not appear in a serviceable event view, no
v SASEXP service action is required.
19B1FFFB 19B1FFFB
Explanation: SAS bus reset occurred
Response: No action required. This reference code is
logged for information only.
19B1FFFC 19B1FFFC
Explanation: Soft device bus error.
Response: If this event appears in a serviceable event
view, work with the failing item list found there. If this
event does not appear in a serviceable event view, no
service action is required.
Failing Item:
v SIP3250
v DISKDRV
v STORIOA
19B1FFFD 19B1FFFD
Explanation: Soft device bus error.
Response: If this event appears in a serviceable event
view, work with the failing item list found there. If this
event does not appear in a serviceable event view, no
service action is required.
Failing Item:
v SIP3250
v DISKDRV
v STORIOA
Response: No action required. This reference code is Explanation: Device Licensed Internal Code
logged for information only. Response: The device is not supported with the level
of code currently on the system. Contact your next
19B33100 19B33100 level of support.
19B3FFF4 19B3FFF4
19B34060 19B34060
Explanation: Disk device problem
Explanation: Multipath redundancy level reduced
Failing Item:
Response: A redundant disk unit connection has
failed. v DISKDRV
v STORIOA
Failing Item:
v SIP3153
19B3FFF5 19B3FFF5
v SASCABL
v SASEXP Explanation: Disk sector read error
Response: If this event appears in a serviceable event
19B34061 19B34061 view, work with the failing item list found there. If this
event does not appear in a serviceable event view, no
Explanation: Multipath redundancy level increased service action is required.
Response: A redundant disk unit connection has been Failing Item:
restored. No service action is required.
v DISKDRV
19B34100 19B34100
19B3FFF6 19B3FFF6
Explanation: Device bus fabric error
Explanation: Disk device detected recoverable error
Failing Item:
Response: If this event appears in a serviceable event
v SIP3152 view, work with the failing item list found there. If this
v SASCABL event does not appear in a serviceable event view, no
v SASEXP service action is required.
19B3FFFB 19B3FFFB
Explanation: SAS bus reset occurred
Response: No action required. This reference code is
logged for information only.
19B3FFFC 19B3FFFC
Explanation: Soft device bus error.
Response: If this event appears in a serviceable event
view, work with the failing item list found there. If this
event does not appear in a serviceable event view, no
service action is required.
Failing Item:
v SIP3250
v DISKDRV
v STORIOA
19B3FFFD 19B3FFFD
Explanation: Soft device bus error.
Response: If this event appears in a serviceable event
view, work with the failing item list found there. If this
event does not appear in a serviceable event view, no
service action is required.
Failing Item:
v SIP3250
v DISKDRV
v STORIOA
Response: No action required. This reference code is Explanation: Device Licensed Internal Code
logged for information only. Response: The device is not supported with the level
of code currently on the system. Contact your next
19B53100 19B53100 level of support.
19B5FFF4 19B5FFF4
19B54060 19B54060
Explanation: Disk device problem
Explanation: Multipath redundancy level reduced
Failing Item:
Response: A redundant disk unit connection has
failed. v DISKDRV
v STORIOA
Failing Item:
v SIP3153
19B5FFF5 19B5FFF5
v SASCABL
v SASEXP Explanation: Disk sector read error
Response: If this event appears in a serviceable event
19B54061 19B54061 view, work with the failing item list found there. If this
event does not appear in a serviceable event view, no
Explanation: Multipath redundancy level increased service action is required.
Response: A redundant disk unit connection has been Failing Item:
restored. No service action is required.
v DISKDRV
19B54100 19B54100
19B5FFF6 19B5FFF6
Explanation: Device bus fabric error
Explanation: Disk device detected recoverable error
Failing Item:
Response: If this event appears in a serviceable event
v SIP3152 view, work with the failing item list found there. If this
v SASCABL event does not appear in a serviceable event view, no
v SASEXP service action is required.
19B5FFFB 19B5FFFB
Explanation: SAS bus reset occurred
Response: No action required. This reference code is
logged for information only.
19B5FFFC 19B5FFFC
Explanation: Soft device bus error.
Response: If this event appears in a serviceable event
view, work with the failing item list found there. If this
event does not appear in a serviceable event view, no
service action is required.
Failing Item:
v SIP3250
v DISKDRV
v STORIOA
19B5FFFD 19B5FFFD
Explanation: Soft device bus error.
Response: If this event appears in a serviceable event
view, work with the failing item list found there. If this
event does not appear in a serviceable event view, no
service action is required.
Failing Item:
v SIP3250
v DISKDRV
v STORIOA
Response: No action required. This reference code is Explanation: Device Licensed Internal Code
logged for information only. Response: The device is not supported with the level
of code currently on the system. Contact your next
19B73100 19B73100 level of support.
19B7FFF4 19B7FFF4
19B74060 19B74060
Explanation: Disk device problem
Explanation: Multipath redundancy level reduced
Failing Item:
Response: A redundant disk unit connection has
failed. v DISKDRV
v STORIOA
Failing Item:
v SIP3153
19B7FFF5 19B7FFF5
v SASCABL
v SASEXP Explanation: Disk sector read error
Response: If this event appears in a serviceable event
19B74061 19B74061 view, work with the failing item list found there. If this
event does not appear in a serviceable event view, no
Explanation: Multipath redundancy level increased service action is required.
Response: A redundant disk unit connection has been Failing Item:
restored. No service action is required.
v DISKDRV
19B74100 19B74100
19B7FFF6 19B7FFF6
Explanation: Device bus fabric error
Explanation: Disk device detected recoverable error
Failing Item:
Response: If this event appears in a serviceable event
v SIP3152 view, work with the failing item list found there. If this
v SASCABL event does not appear in a serviceable event view, no
v SASEXP service action is required.
19B7FFFB 19B7FFFB
Explanation: SAS bus reset occurred
Response: No action required. This reference code is
logged for information only.
19B7FFFC 19B7FFFC
Explanation: Soft device bus error.
Response: If this event appears in a serviceable event
view, work with the failing item list found there. If this
event does not appear in a serviceable event view, no
service action is required.
Failing Item:
v SIP3250
v DISKDRV
v STORIOA
19B7FFFD 19B7FFFD
Explanation: Soft device bus error.
Response: If this event appears in a serviceable event
view, work with the failing item list found there. If this
event does not appear in a serviceable event view, no
service action is required.
Failing Item:
v SIP3250
v DISKDRV
v STORIOA
2105FFF6 2105FFF6
Explanation: Disk device detected recoverable error
Response: If this event appears in a serviceable event
view, work with the failing item list found there. If this
event does not appear in a serviceable event view, no
service action is required.
Failing Item:
v FCDEV
2105FFFA 2105FFFA
Explanation: Disk device wrong response was
recovered by the IOP
Response: If this event appears in a serviceable event
view, work with the failing item list found there. If this
event does not appear in a serviceable event view, no
service action is required.
Failing Item:
v FCDEV
v FCIOA
v OPT_CLN
2105FFFE 2105FFFE
Explanation: Temporary Fibre Channel interface error.
Response: If this event appears in a serviceable event
view, work with the failing item list found there. If this
event does not appear in a serviceable event view, no
service action is required.
Failing Item:
v FCINTF
v FCDEV
v FCIOA
v OPT_CLN
2107FFF6 2107FFF6
Explanation: Disk device detected recoverable error
Response: If this event appears in a serviceable event
view, work with the failing item list found there. If this
event does not appear in a serviceable event view, no
service action is required.
Failing Item:
v FCDEV
2107FFFA 2107FFFA
Explanation: Disk device wrong response was
recovered by the IOP
Response: If this event appears in a serviceable event
view, work with the failing item list found there. If this
event does not appear in a serviceable event view, no
service action is required.
Failing Item:
v FCDEV
v FCIOA
v OPT_CLN
2107FFFE 2107FFFE
Explanation: Temporary Fibre Channel interface error.
Response: If this event appears in a serviceable event
view, work with the failing item list found there. If this
event does not appear in a serviceable event view, no
service action is required.
Failing Item:
v FCINTF
v FCDEV
v FCIOA
v OPT_CLN
266DB9B0 266DB9B0
Explanation: I/O adapter hardware error detected
Failing Item:
v IOA
v AJDG301
266EB9B0 266EB9B0
Explanation: I/O adapter hardware error detected
Failing Item:
v IOA
v AJDG301
266FB904 266FB904
Explanation: I/O Adapter Licensed Internal Code
failed
Failing Item:
v AJDGP01
v FI00719
266FB934 266FB934
Explanation: Incompatible hardware detected.
Failing Item:
v FI00719
v FI00718
266FB940 266FB940
Explanation: I/O adapter hardware error detected.
Failing Item:
v FI00719
v FI00718
v AJDGP01
v MA_BRDG
266FB941 266FB941
Explanation: One half of I/O adapter failed.
Failing Item:
v FI00719
v FI00718
v AJDGP01
266FB942 266FB942
Explanation: One half of I/O adapter failed.
Failing Item:
v FI00719
v FI00718
v AJDGP01
Explanation: Adapter card storage error Explanation: I/O adapter Licensed Internal Code
failed.
Failing Item:
Failing Item:
v AJDGP01
v AJDGP01
v AJDG301
v IOA
26893081 26893081
Failing Item:
26896228 26896228
v NETSERV
v IOA Explanation: Windows initiated a warm boot
v AJDGP01 Failing Item:
v AJDGP01
v IOA
26896534 26896534
Explanation: A Virtual SCSI error was detected.
26896501 26896501
Failing Item:
Explanation: A Windows fatal error occurred
v AS4NTDD
Failing Item:
v AJDGP01
v IOA
v NTOPSYS
v AJDGP01
26896535 26896535
26896502 26896502
Explanation: A Virtual SCSI error was detected.
Explanation: A Windows fatal error occurred
Failing Item:
Failing Item:
v NTUSER
v AJDGP01
v NTDEVDR
v IOA
v AJDGP01
26896530 26896530
26896538 26896538
Explanation: A Virtual SCSI error was detected.
Explanation: A Virtual SCSI error was detected.
Failing Item:
Failing Item:
v NTVSCSI
v NTVSCSI
v NTOPSYS
v NTOPSYS
26896531 26896531
26896539 26896539
Explanation: A Virtual SCSI error was detected.
Explanation: A Virtual SCSI error was detected.
Failing Item:
Failing Item:
v NTVSCSI
v NTVSCSI
v AS4NTDD
v AS4NTDD
v NTOPSYS
v NTOPSYS
v AJDGP01
v AJDGP01
26896532 26896532
2689653A 2689653A
Explanation: A Virtual SCSI error was detected.
Explanation: A Virtual SCSI error was detected.
Failing Item:
Failing Item:
v NTOPSYS
v NTOPSYS
v AJDGP01
v AJDGP01
v AS4NTDD
v AS4NTDD
26896533 26896533
2689653B 2689653B
Explanation: A Virtual SCSI error was detected.
Explanation: A Virtual SCSI error was detected.
Failing Item:
Failing Item:
v NTUSER
v NTUSER
v NTOPSYS
v NTOPSYS
v AS4NTDD
v AS4NTDD
v NTVSCSI
2689653C 2689653C
Explanation: A Virtual SCSI error was detected.
26896544 26896544
Failing Item:
Explanation: A Virtual SCSI error was detected.
v AS4NTDD
Failing Item:
v AJDGP01
v NTVSCSI
v NTOPSYS
v NTOPSYS
2689653D 2689653D
26896580 26896580
Explanation: A Virtual SCSI error was detected.
Explanation: A Windows fatal error occurred
Failing Item:
Failing Item:
v NTUSER
v DISKIMG
v NTDEVDR
v IOA
v AJDGP01
v AJDGP01
2689653F 2689653F
26896590 26896590
Explanation: A Virtual SCSI error was detected.
Explanation: A Netfinity Server error was detected
Failing Item:
v NTDEVDR
268965B0 268965B0
v NTOPSYS
Explanation: A HostLAN error was detected
v AJDG301
Failing Item:
26896540 26896540 v NTLANDD
v NTOPSYS
Explanation: A Virtual SCSI error was detected.
Failing Item:
268965B1 268965B1
v NTVSCSI
Explanation: A HostLAN error was detected
v AJDGP01
v AJDG301 Failing Item:
v NTLANDD
26896541 26896541 v NTOPSYS
v AJDG301
Explanation: A permanent I/O processor failure
occurred
268965B2 268965B2
Failing Item:
v IOA Explanation: A HostLAN error was detected
v AJDGP01 Failing Item:
v NTDEVDR
26896542 26896542 v NTOPSYS
Explanation: Licensed Internal Code error detected. v AJDG301
Failing Item:
26898301 26898301
v AJDG301
v AJDGP01 Explanation: An I/O adapter failure occurred.
Failing Item:
26896543 26896543 v AJDGP01
Explanation: A Windows fatal error occurred v IOA
Failing Item:
v NTOPSYS
Failing Item:
2689B4B1 2689B4B1
v IOA
Explanation: A Netfinity Server error was detected
2689B3B5 2689B3B5 Failing Item:
Explanation: A permanent I/O processor failure v NETSERV
occurred v AJDGP01
Failing Item:
v IOA 2689B4B9 2689B4B9
Explanation: An I/O adapter failure occurred.
2689B3B6 2689B3B6 Failing Item:
Explanation: A permanent I/O processor failure v IOA
occurred
Failing Item: 2689B4BC 2689B4BC
v IOA Explanation: A Netfinity Server error was detected
Failing Item:
2689B3B7 2689B3B7
v NETSERV
Explanation: A permanent I/O processor failure
occurred
2689B4BF 2689B4BF
Failing Item:
Explanation: A Netfinity Server error was detected
v IOA
Failing Item:
2689B3B8 2689B3B8 v NSCABLE
2689B904 2689B904
Explanation: A permanent I/O processor failure
occurred
Failing Item:
v AJDGP01
v IOA
2689B935 2689B935
Explanation: Incompatible hardware detected.
Failing Item:
v AJDGP01
v IOA
2689B960 2689B960
Explanation: I/O processor Licensed Internal Code
error
Failing Item:
v AJDGP01
v IOA
2689BE00 2689BE00
Explanation: An I/O adapter failure occurred.
Failing Item:
v AJDGP01
v IOA
2742B940 2742B940
Explanation: I/O adapter hardware error detected
Failing Item:
v FI00719
v AJDGP01
v MA_BRDG
2742B941 2742B941
Explanation: One of the ports on the IOA has failed.
Failing Item:
v FI00719
v AJDGP01
2743B951 2743B951
Explanation: I/O adapter hardware error detected
Failing Item:
v FI00719
v FI00718
v AJDGP01
v MA_BRDG
2744B920 2744B920
Explanation: I/O adapter Licensed Internal Code
failed
Failing Item:
v AJDGP01
v FI00718
v FI00719
2744B921 2744B921
Explanation: I/O adapter hardware error detected
Failing Item:
v FI00719
v FI00718
v AJDGP01
v MA_BRDG
2744B934 2744B934
Explanation: Incompatible hardware detected.
Failing Item:
v FI00719
v FI00718
2745B934 2745B934
Explanation: Incompatible hardware detected.
Failing Item:
v FI00719
v FI00718
2745B940 2745B940
Explanation: I/O adapter hardware error detected.
Failing Item:
v FI00719
v FI00718
v AJDGP01
v MA_BRDG
2745B941 2745B941
Explanation: One half of I/O adapter failed.
Failing Item:
v FI00719
v FI00718
v AJDGP01
2745B942 2745B942
Explanation: One half of I/O adapter failed.
Failing Item:
v FI00719
v FI00718
v AJDGP01
2746B934 2746B934
Explanation: Incompatible hardware detected.
Failing Item:
v FI00719
v FI00718
2746B940 2746B940
Explanation: I/O adapter hardware error detected.
Failing Item:
v FI00719
v FI00718
v AJDGP01
v MA_BRDG
2746B941 2746B941
Explanation: One half of I/O adapter failed.
Failing Item:
v FI00719
v FI00718
v AJDGP01
2746B942 2746B942
Explanation: One half of I/O adapter failed.
Failing Item:
v FI00719
v FI00718
v AJDGP01
v AJDGP01 v USER
v IOP v FI01105
v FI01104
v BACKPLN 27492202 27492202
Explanation: Removable media error during IPL
27491307 27491307 Failing Item:
Explanation: I/O processor resource not available v FI00022
Failing Item: v FI01105
v AJDGP01
v AJDG301 27493000 27493000
Explanation: A permanent I/O processor failure
27491310 27491310 occurred
v FI01101 v IOPIP17
v IOP v USER
v MA_BRDG v FI01107
v STORIOA
27493001 27493001
Explanation: Not valid condition in I/O Processor 27493022 27493022
Licensed Internal Code Explanation: I/O processor detected a SCSI bus
Response: The Licensed Internal Code found a configuration error
condition that should not have occurred. Response: Error occurred on SCSI bus 2.
Failing Item: Failing Item:
v IOP v IOPIP17
v AJDGP01 v USER
v FI01107
27493002 27493002 v STORIOA
Explanation: Addressed device failed to respond to
selection 27493023 27493023
Failing Item: Explanation: I/O processor detected a SCSI bus
v IOPIP16 configuration error
v FI01105 Response: Error occurred on SCSI bus 3.
v STORIOA
Failing Item:
v FI01140
v IOPIP17
v FI01141
v USER
v FI01106
v FI01107
v STORIOA
27493006 27493006
Explanation: System bus error 27493080 27493080
Failing Item: Explanation: I/O processor Licensed Internal Code
v IOP error
v ANYBUS Failing Item:
v FI01101 v AJDGP01
Failing Item:
27493102 27493102
27493120 27493120
Explanation: I/O processor card detected interface
error Explanation: I/O Processor detected that the bus is
not operational
Response: Error occurred on SCSI bus 2.
Response: A device was added to SCSI bus 0 of the
Failing Item: I/O Adapter and caused the bus to become not
v IOPIP13 operational. Remove the device.
v FI01107 Failing Item:
v STORIOA v SVCDOCS
v FI01140
v DEVBPLN 27493121 27493121
Explanation: I/O Processor detected that the bus is
not operational
Response: A device was added to SCSI bus 1 of the
I/O Adapter and caused the bus to become not
Explanation: I/O Processor detected that the bus is Response: This reference code and the 3123 reference
not operational code that occurred before it require no service action,
since SCSI bus 3 is now operational.
Response: A device was added to SCSI bus 2 of the
I/O Adapter and caused the bus to become not
operational. Remove the device. 27493150 27493150
Explanation: I/O Processor detected that the bus is Explanation: Disk media format bad
now operational Failing Item:
Response: This reference code and the 3121 reference v FI01105
code that occurred before it require no service action,
since SCSI bus 1 is now operational.
27493205 27493205
Explanation: Disk sector read error
27493142 27493142
Response: Disk unit data may need to be reloaded,
Explanation: I/O Processor detected that the bus is
but the disk unit does not need to be replaced.
now operational
Failing Item:
Response: This reference code and the 3122 reference
code that occurred before it require no service action, v FI01105
27493250 27493250
27496070 27496070
Explanation: Disk unit requires initialization before
use. Explanation: A permanent I/O processor failure
occurred
Response: Perform a D-IPL and work on errors found
in the log. Failing Item:
v IOP
Failing Item:
v USER
27496071 27496071
27496075 27496075
27493401 27493401
Explanation: I/O processor resource not available
Explanation: Device backplane problem
Failing Item:
Failing Item:
v AJDGP01
v DEVBPLN
27496076 27496076
27493501 27493501
Explanation: I/O processor card detected media error
Explanation: I/O processor Licensed Internal Code
error Failing Item:
Failing Item: v MEDIA
v AJDGP01 v AJDGP01
v IOP v FI01105
Response: No action required. Protection will be Explanation: IOP resources not available due to
automatically restarted. previous problems.
Response: Power off the system and remove all new
27499041 27499041 or replacement disk units. IPL the system to DST. If
you cannot perform a type A or B IPL, perform a type
Explanation: Background array parity check detected D IPL from removable media.
and corrected errors
Look for Product Activity Log entries for other IOP
Response: Call your next level of support to report reference codes and take action on them.
the problem.
Failing Item:
Failing Item:
v SVCDOCS
v AJDGP01
27499081 27499081
27499050 27499050
Explanation: I/O processor card detected device error
Explanation: Required cache data cannot be located
for a disk unit. Failing Item:
v FI01105
Failing Item:
v STORIOA
v IOPIP30
v IOP
2749BE00 2749BE00
Explanation: I/O processor detected a fault condition
2749B3E0 2749B3E0
Failing Item:
Explanation: I/O processor detected a fault condition
v AJDGP01
Failing Item:
v IOP
v IOP
v FI01104
v MA_BRDG
v MA_BRDG
2749B3E1 2749B3E1
2749FF3D 2749FF3D
Explanation: I/O processor detected a fault condition
Explanation: I/O adapter detected recoverable error
Failing Item:
Failing Item:
v IOP
v STORIOA
v MA_BRDG
v ANYBRDG
2749B410 2749B410
2749FF6D 2749FF6D
Explanation: A permanent I/O processor failure
Explanation: I/O processor detected a recoverable
occurred
system bus error
Failing Item:
Failing Item:
v STORIOA
v IOP
v ANYBUS
2749B411 2749B411
Explanation: A permanent I/O processor failure
occurred
Failing Item:
v STORIOA
2749B412 2749B412
Explanation: Tape/CD or disk bus interface error
occurred
Failing Item:
v IOPIP16
v FI01107
v FI01140
v STORIOA
v DEVTERM
2749B935 2749B935
Explanation: Unknown hardware detected
Failing Item:
v FI01101
v AJDGP01
v IOP
v MA_BRDG
Explanation: I/O processor detected a SCSI bus Response: Error occurred on SCSI bus 0.
configuration error Failing Item:
Response: Error occurred on SCSI bus 0. v IOPIP13
Failing Item: v FI01107
v IOPIP17 v STORIOA
v USER v FI01140
v FI01107 v DEVBPLN
v STORIOA
27573101 27573101
27573021 27573021 Explanation: I/O processor card detected interface
error
Explanation: I/O processor detected a SCSI bus
configuration error Response: Error occurred on SCSI bus 1.
Response: Error occurred on SCSI bus 1. Failing Item:
Failing Item: v IOPIP13
v IOPIP17 v FI01107
v USER v STORIOA
v FI01107 v FI01140
v STORIOA v DEVBPLN
Explanation: I/O processor detected a SCSI bus Explanation: I/O processor card detected interface
configuration error error
Response: Error occurred on SCSI bus 2. Response: Error occurred on SCSI bus 2.
v FI01140 v SVCDOCS
v DEVBPLN
27573140 27573140
27573103 27573103 Explanation: I/O Processor detected that the bus is
Explanation: I/O processor card detected interface now operational
error Response: This reference code and the 3120 reference
Response: Error occurred on SCSI bus 3. code that occurred before it require no service action,
since SCSI bus 0 is now operational.
Failing Item:
v IOPIP13
27573141 27573141
v FI01107
Explanation: I/O Processor detected that the bus is
v STORIOA
now operational
v FI01140
Response: This reference code and the 3121 reference
v DEVBPLN
code that occurred before it require no service action,
since SCSI bus 1 is now operational.
27573120 27573120
Explanation: I/O Processor detected that the bus is 27573142 27573142
not operational
Explanation: I/O Processor detected that the bus is
Response: A device was added to SCSI bus 0 of the now operational
I/O Adapter and caused the bus to become not
Response: This reference code and the 3122 reference
operational. Remove the device.
code that occurred before it require no service action,
Failing Item: since SCSI bus 2 is now operational.
v SVCDOCS
27573143 27573143
27573121 27573121 Explanation: I/O Processor detected that the bus is
Explanation: I/O Processor detected that the bus is now operational
not operational Response: This reference code and the 3123 reference
Response: A device was added to SCSI bus 1 of the code that occurred before it require no service action,
I/O Adapter and caused the bus to become not since SCSI bus 3 is now operational.
operational. Remove the device.
Failing Item: 27573150 27573150
v ANYBRDG
2757FF6D 2757FF6D
Explanation: I/O processor detected a recoverable
system bus error
Failing Item:
v IOP
v ANYBUS
2760B951 2760B951
Explanation: I/O adapter hardware error detected
Failing Item:
v FI00719
v FI00718
v AJDGP01
v MA_BRDG
Explanation: I/O processor detected a SCSI bus Response: Error occurred on SCSI bus 0.
configuration error Failing Item:
Response: Error occurred on SCSI bus 0. v IOPIP13
Failing Item: v FI01107
v IOPIP17 v STORIOA
v USER v FI01140
v FI01107 v DEVBPLN
v STORIOA
27633101 27633101
27633021 27633021 Explanation: I/O processor card detected interface
error
Explanation: I/O processor detected a SCSI bus
configuration error Response: Error occurred on SCSI bus 1.
Response: Error occurred on SCSI bus 1. Failing Item:
Failing Item: v IOPIP13
v IOPIP17 v FI01107
v USER v STORIOA
v FI01107 v FI01140
v STORIOA v DEVBPLN
Explanation: I/O processor detected a SCSI bus Explanation: I/O processor card detected interface
configuration error error
Response: Error occurred on SCSI bus 2. Response: Error occurred on SCSI bus 2.
v FI01140 v SVCDOCS
v DEVBPLN
27633140 27633140
27633103 27633103 Explanation: I/O Processor detected that the bus is
Explanation: I/O processor card detected interface now operational
error Response: This reference code and the 3120 reference
Response: Error occurred on SCSI bus 3. code that occurred before it require no service action,
since SCSI bus 0 is now operational.
Failing Item:
v IOPIP13
27633141 27633141
v FI01107
Explanation: I/O Processor detected that the bus is
v STORIOA
now operational
v FI01140
Response: This reference code and the 3121 reference
v DEVBPLN
code that occurred before it require no service action,
since SCSI bus 1 is now operational.
27633120 27633120
Explanation: I/O Processor detected that the bus is 27633142 27633142
not operational
Explanation: I/O Processor detected that the bus is
Response: A device was added to SCSI bus 0 of the now operational
I/O Adapter and caused the bus to become not
Response: This reference code and the 3122 reference
operational. Remove the device.
code that occurred before it require no service action,
Failing Item: since SCSI bus 2 is now operational.
v SVCDOCS
27633143 27633143
27633121 27633121 Explanation: I/O Processor detected that the bus is
Explanation: I/O Processor detected that the bus is now operational
not operational Response: This reference code and the 3123 reference
Response: A device was added to SCSI bus 1 of the code that occurred before it require no service action,
I/O Adapter and caused the bus to become not since SCSI bus 3 is now operational.
operational. Remove the device.
Failing Item: 27633150 27633150
v ANYBRDG
2763FF6D 2763FF6D
Explanation: I/O processor detected a recoverable
system bus error
Failing Item:
v IOP
v ANYBUS
v AJDGP01 v USER
v IOP v FI01105
v FI01104
v BACKPLN 27672202 27672202
Explanation: Removable media error during IPL
27671307 27671307 Failing Item:
Explanation: I/O processor resource not available v FI00022
Failing Item: v FI01105
v AJDGP01
v AJDG301 27673000 27673000
Explanation: A permanent I/O processor failure
27671310 27671310 occurred
v FI01101 v IOPIP17
v IOP v USER
v MA_BRDG v FI01107
v STORIOA
27673001 27673001
Explanation: Not valid condition in I/O Processor 27673022 27673022
Licensed Internal Code Explanation: I/O processor detected a SCSI bus
Response: The Licensed Internal Code found a configuration error
condition that should not have occurred. Response: Error occurred on SCSI bus 2.
Failing Item: Failing Item:
v IOP v IOPIP17
v AJDGP01 v USER
v FI01107
27673002 27673002 v STORIOA
Explanation: Addressed device failed to respond to
selection 27673023 27673023
Failing Item: Explanation: I/O processor detected a SCSI bus
v IOPIP16 configuration error
v FI01105 Response: Error occurred on SCSI bus 3.
v STORIOA
Failing Item:
v FI01140
v IOPIP17
v FI01141
v USER
v FI01106
v FI01107
v STORIOA
27673006 27673006
Explanation: System bus error 27673080 27673080
Failing Item: Explanation: I/O processor Licensed Internal Code
v IOP error
v ANYBUS Failing Item:
v FI01101 v AJDGP01
Failing Item:
27673102 27673102
27673120 27673120
Explanation: I/O processor card detected interface
error Explanation: I/O Processor detected that the bus is
not operational
Response: Error occurred on SCSI bus 2.
Response: A device was added to SCSI bus 0 of the
Failing Item: I/O Adapter and caused the bus to become not
v IOPIP13 operational. Remove the device.
v FI01107 Failing Item:
v STORIOA v SVCDOCS
v FI01140
v DEVBPLN 27673121 27673121
Explanation: I/O Processor detected that the bus is
not operational
Response: A device was added to SCSI bus 1 of the
I/O Adapter and caused the bus to become not
Explanation: I/O Processor detected that the bus is Response: This reference code and the 3123 reference
not operational code that occurred before it require no service action,
since SCSI bus 3 is now operational.
Response: A device was added to SCSI bus 2 of the
I/O Adapter and caused the bus to become not
operational. Remove the device. 27673150 27673150
Explanation: I/O Processor detected that the bus is Explanation: Disk media format bad
now operational Failing Item:
Response: This reference code and the 3121 reference v FI01105
code that occurred before it require no service action,
since SCSI bus 1 is now operational.
27673205 27673205
Explanation: Disk sector read error
27673142 27673142
Response: Disk unit data may need to be reloaded,
Explanation: I/O Processor detected that the bus is
but the disk unit does not need to be replaced.
now operational
Failing Item:
Response: This reference code and the 3122 reference
code that occurred before it require no service action, v FI01105
27673250 27673250
27676070 27676070
Explanation: Disk unit requires initialization before
use. Explanation: A permanent I/O processor failure
occurred
Response: Perform a D-IPL and work on errors found
in the log. Failing Item:
v IOP
Failing Item:
v USER
27676071 27676071
27676075 27676075
27673401 27673401
Explanation: I/O processor resource not available
Explanation: Device backplane problem
Failing Item:
Failing Item:
v AJDGP01
v DEVBPLN
27676076 27676076
27673501 27673501
Explanation: I/O processor card detected media error
Explanation: I/O processor Licensed Internal Code
error Failing Item:
Failing Item: v MEDIA
v AJDGP01 v AJDGP01
v IOP v FI01105
Response: No action required. Protection will be Explanation: IOP resources not available due to
automatically restarted. previous problems.
Response: Power off the system and remove all new
27679041 27679041 or replacement disk units. IPL the system to DST. If
you cannot perform a type A or B IPL, perform a type
Explanation: Background array parity check detected D IPL from removable media.
and corrected errors
Look for Product Activity Log entries for other IOP
Response: Call your next level of support to report reference codes and take action on them.
the problem.
Failing Item:
Failing Item:
v SVCDOCS
v AJDGP01
27679081 27679081
27679050 27679050
Explanation: I/O processor card detected device error
Explanation: Required cache data cannot be located
for a disk unit. Failing Item:
v FI01105
Failing Item:
v STORIOA
v IOPIP30
v IOP
2767BE00 2767BE00
Explanation: I/O processor detected a fault condition
2767B3E0 2767B3E0
Failing Item:
Explanation: I/O processor detected a fault condition
v AJDGP01
Failing Item:
v IOP
v IOP
v FI01104
v MA_BRDG
v MA_BRDG
2767B3E1 2767B3E1
2767FF3D 2767FF3D
Explanation: I/O processor detected a fault condition
Explanation: I/O adapter detected recoverable error
Failing Item:
Failing Item:
v IOP
v STORIOA
v MA_BRDG
v ANYBRDG
2767B410 2767B410
2767FF6D 2767FF6D
Explanation: A permanent I/O processor failure
Explanation: I/O processor detected a recoverable
occurred
system bus error
Failing Item:
Failing Item:
v STORIOA
v IOP
v ANYBUS
2767B411 2767B411
Explanation: A permanent I/O processor failure
occurred
Failing Item:
v STORIOA
2767B412 2767B412
Explanation: Tape/CD or disk bus interface error
occurred
Failing Item:
v IOPIP16
v FI01107
v FI01140
v STORIOA
v DEVTERM
2767B935 2767B935
Explanation: Unknown hardware detected
Failing Item:
v FI01101
v AJDGP01
v IOP
v MA_BRDG
v AJDGP01 v USER
v IOP v FI01105
v FI01104
v BACKPLN 27682202 27682202
Explanation: Removable media error during IPL
27681307 27681307 Failing Item:
Explanation: I/O processor resource not available v FI00022
Failing Item: v FI01105
v AJDGP01
v AJDG301 27683000 27683000
Explanation: A permanent I/O processor failure
27681310 27681310 occurred
v FI01101 v IOPIP17
v IOP v USER
v MA_BRDG v FI01107
v STORIOA
27683001 27683001
Explanation: Not valid condition in I/O Processor 27683022 27683022
Licensed Internal Code Explanation: I/O processor detected a SCSI bus
Response: The Licensed Internal Code found a configuration error
condition that should not have occurred. Response: Error occurred on SCSI bus 2.
Failing Item: Failing Item:
v IOP v IOPIP17
v AJDGP01 v USER
v FI01107
27683002 27683002 v STORIOA
Explanation: Addressed device failed to respond to
selection 27683023 27683023
Failing Item: Explanation: I/O processor detected a SCSI bus
v IOPIP16 configuration error
v FI01105 Response: Error occurred on SCSI bus 3.
v STORIOA
Failing Item:
v FI01140
v IOPIP17
v FI01141
v USER
v FI01106
v FI01107
v STORIOA
27683006 27683006
Explanation: System bus error 27683080 27683080
Failing Item: Explanation: I/O processor Licensed Internal Code
v IOP error
v ANYBUS Failing Item:
v FI01101 v AJDGP01
Failing Item:
27683102 27683102
27683120 27683120
Explanation: I/O processor card detected interface
error Explanation: I/O Processor detected that the bus is
not operational
Response: Error occurred on SCSI bus 2.
Response: A device was added to SCSI bus 0 of the
Failing Item: I/O Adapter and caused the bus to become not
v IOPIP13 operational. Remove the device.
v FI01107 Failing Item:
v STORIOA v SVCDOCS
v FI01140
v DEVBPLN 27683121 27683121
Explanation: I/O Processor detected that the bus is
not operational
Response: A device was added to SCSI bus 1 of the
I/O Adapter and caused the bus to become not
Explanation: I/O Processor detected that the bus is Response: This reference code and the 3123 reference
not operational code that occurred before it require no service action,
since SCSI bus 3 is now operational.
Response: A device was added to SCSI bus 2 of the
I/O Adapter and caused the bus to become not
operational. Remove the device. 27683150 27683150
Explanation: I/O Processor detected that the bus is Explanation: Disk media format bad
now operational Failing Item:
Response: This reference code and the 3121 reference v FI01105
code that occurred before it require no service action,
since SCSI bus 1 is now operational.
27683205 27683205
Explanation: Disk sector read error
27683142 27683142
Response: Disk unit data may need to be reloaded,
Explanation: I/O Processor detected that the bus is
but the disk unit does not need to be replaced.
now operational
Failing Item:
Response: This reference code and the 3122 reference
code that occurred before it require no service action, v FI01105
27683250 27683250
27686070 27686070
Explanation: Disk unit requires initialization before
use. Explanation: A permanent I/O processor failure
occurred
Response: Perform a D-IPL and work on errors found
in the log. Failing Item:
v IOP
Failing Item:
v USER
27686071 27686071
27686075 27686075
27683401 27683401
Explanation: I/O processor resource not available
Explanation: Device backplane problem
Failing Item:
Failing Item:
v AJDGP01
v DEVBPLN
27686076 27686076
27683501 27683501
Explanation: I/O processor card detected media error
Explanation: I/O processor Licensed Internal Code
error Failing Item:
Failing Item: v MEDIA
v AJDGP01 v AJDGP01
v IOP v FI01105
Response: No action required. Protection will be Explanation: IOP resources not available due to
automatically restarted. previous problems.
Response: Power off the system and remove all new
27689041 27689041 or replacement disk units. IPL the system to DST. If
you cannot perform a type A or B IPL, perform a type
Explanation: Background array parity check detected D IPL from removable media.
and corrected errors
Look for Product Activity Log entries for other IOP
Response: Call your next level of support to report reference codes and take action on them.
the problem.
Failing Item:
Failing Item:
v SVCDOCS
v AJDGP01
27689081 27689081
27689050 27689050
Explanation: I/O processor card detected device error
Explanation: Required cache data cannot be located
for a disk unit. Failing Item:
v FI01105
Failing Item:
v STORIOA
v IOPIP30
v IOP
2768BE00 2768BE00
Explanation: I/O processor detected a fault condition
2768B3E0 2768B3E0
Failing Item:
Explanation: I/O processor detected a fault condition
v AJDGP01
Failing Item:
v IOP
v IOP
v FI01104
v MA_BRDG
v MA_BRDG
2768B3E1 2768B3E1
2768FF3D 2768FF3D
Explanation: I/O processor detected a fault condition
Explanation: I/O adapter detected recoverable error
Failing Item:
Failing Item:
v IOP
v STORIOA
v MA_BRDG
v ANYBRDG
2768B410 2768B410
2768FF6D 2768FF6D
Explanation: A permanent I/O processor failure
Explanation: I/O processor detected a recoverable
occurred
system bus error
Failing Item:
Failing Item:
v STORIOA
v IOP
v ANYBUS
2768B411 2768B411
Explanation: A permanent I/O processor failure
occurred
Failing Item:
v STORIOA
2768B412 2768B412
Explanation: Tape/CD or disk bus interface error
occurred
Failing Item:
v IOPIP16
v FI01107
v FI01140
v STORIOA
v DEVTERM
2768B935 2768B935
Explanation: Unknown hardware detected
Failing Item:
v FI01101
v AJDGP01
v IOP
v MA_BRDG
2771B934 2771B934
Explanation: Incompatible hardware detected.
Failing Item:
v FI00719
v FI00718
2771B940 2771B940
Explanation: I/O adapter hardware error detected.
Failing Item:
v FI00719
v FI00718
v AJDGP01
v MA_BRDG
2771B941 2771B941
Explanation: One half of I/O adapter failed.
Failing Item:
v FI00719
v FI00718
v AJDGP01
2771B942 2771B942
Explanation: One half of I/O adapter failed.
Failing Item:
v FI00719
v FI00718
v AJDGP01
2772B934 2772B934
Explanation: Incompatible hardware detected.
Failing Item:
v FI00719
v FI00718
2772B940 2772B940
Explanation: I/O adapter hardware error detected.
Failing Item:
v FI00719
v FI00718
v AJDGP01
v MA_BRDG
2772B941 2772B941
Explanation: One half of I/O adapter failed.
Failing Item:
v FI00719
v FI00718
v AJDGP01
2772B942 2772B942
Explanation: One half of I/O adapter failed.
Failing Item:
v FI00719
v FI00718
v AJDGP01
Explanation: I/O processor detected a SCSI bus Response: Error occurred on SCSI bus 0.
configuration error Failing Item:
Response: Error occurred on SCSI bus 0. v IOPIP13
Failing Item: v FI01107
v IOPIP17 v STORIOA
v USER v FI01140
v FI01107 v DEVBPLN
v STORIOA
27803101 27803101
27803021 27803021 Explanation: I/O processor card detected interface
error
Explanation: I/O processor detected a SCSI bus
configuration error Response: Error occurred on SCSI bus 1.
Response: Error occurred on SCSI bus 1. Failing Item:
Failing Item: v IOPIP13
v IOPIP17 v FI01107
v USER v STORIOA
v FI01107 v FI01140
v STORIOA v DEVBPLN
Explanation: I/O processor detected a SCSI bus Explanation: I/O processor card detected interface
configuration error error
Response: Error occurred on SCSI bus 2. Response: Error occurred on SCSI bus 2.
v FI01140 v SVCDOCS
v DEVBPLN
27803140 27803140
27803103 27803103 Explanation: I/O Processor detected that the bus is
Explanation: I/O processor card detected interface now operational
error Response: This reference code and the 3120 reference
Response: Error occurred on SCSI bus 3. code that occurred before it require no service action,
since SCSI bus 0 is now operational.
Failing Item:
v IOPIP13
27803141 27803141
v FI01107
Explanation: I/O Processor detected that the bus is
v STORIOA
now operational
v FI01140
Response: This reference code and the 3121 reference
v DEVBPLN
code that occurred before it require no service action,
since SCSI bus 1 is now operational.
27803120 27803120
Explanation: I/O Processor detected that the bus is 27803142 27803142
not operational
Explanation: I/O Processor detected that the bus is
Response: A device was added to SCSI bus 0 of the now operational
I/O Adapter and caused the bus to become not
Response: This reference code and the 3122 reference
operational. Remove the device.
code that occurred before it require no service action,
Failing Item: since SCSI bus 2 is now operational.
v SVCDOCS
27803143 27803143
27803121 27803121 Explanation: I/O Processor detected that the bus is
Explanation: I/O Processor detected that the bus is now operational
not operational Response: This reference code and the 3123 reference
Response: A device was added to SCSI bus 1 of the code that occurred before it require no service action,
I/O Adapter and caused the bus to become not since SCSI bus 3 is now operational.
operational. Remove the device.
Failing Item: 27803150 27803150
v ANYBRDG
2780FF6D 2780FF6D
Explanation: I/O processor detected a recoverable
system bus error
Failing Item:
v IOP
v ANYBUS
Explanation: I/O processor detected a SCSI bus Response: Error occurred on SCSI bus 0.
configuration error Failing Item:
Response: Error occurred on SCSI bus 0. v IOPIP13
Failing Item: v FI01107
v IOPIP17 v STORIOA
v USER v FI01140
v FI01107 v DEVBPLN
v STORIOA
27823101 27823101
27823021 27823021 Explanation: I/O processor card detected interface
error
Explanation: I/O processor detected a SCSI bus
configuration error Response: Error occurred on SCSI bus 1.
Response: Error occurred on SCSI bus 1. Failing Item:
Failing Item: v IOPIP13
v IOPIP17 v FI01107
v USER v STORIOA
v FI01107 v FI01140
v STORIOA v DEVBPLN
Explanation: I/O processor detected a SCSI bus Explanation: I/O processor card detected interface
configuration error error
Response: Error occurred on SCSI bus 2. Response: Error occurred on SCSI bus 2.
v FI01140 v SVCDOCS
v DEVBPLN
27823140 27823140
27823103 27823103 Explanation: I/O Processor detected that the bus is
Explanation: I/O processor card detected interface now operational
error Response: This reference code and the 3120 reference
Response: Error occurred on SCSI bus 3. code that occurred before it require no service action,
since SCSI bus 0 is now operational.
Failing Item:
v IOPIP13
27823141 27823141
v FI01107
Explanation: I/O Processor detected that the bus is
v STORIOA
now operational
v FI01140
Response: This reference code and the 3121 reference
v DEVBPLN
code that occurred before it require no service action,
since SCSI bus 1 is now operational.
27823120 27823120
Explanation: I/O Processor detected that the bus is 27823142 27823142
not operational
Explanation: I/O Processor detected that the bus is
Response: A device was added to SCSI bus 0 of the now operational
I/O Adapter and caused the bus to become not
Response: This reference code and the 3122 reference
operational. Remove the device.
code that occurred before it require no service action,
Failing Item: since SCSI bus 2 is now operational.
v SVCDOCS
27823143 27823143
27823121 27823121 Explanation: I/O Processor detected that the bus is
Explanation: I/O Processor detected that the bus is now operational
not operational Response: This reference code and the 3123 reference
Response: A device was added to SCSI bus 1 of the code that occurred before it require no service action,
I/O Adapter and caused the bus to become not since SCSI bus 3 is now operational.
operational. Remove the device.
Failing Item: 27823150 27823150
v ANYBRDG
2782FF6D 2782FF6D
Explanation: I/O processor detected a recoverable
system bus error
Failing Item:
v IOP
v ANYBUS
Explanation: A permanent I/O processor failure IPL the I/O processor, see Debug the resource. If an
occurred I/O processor reset and I/O processor IPL does not
resolve the problem, contact your next level of support.
Failing Item:
v FCIOA Failing Item:
v ANYBRDG v SVCDOCS
v OPT_CLN
2787FF3D 2787FF3D
27878151 27878151 Explanation: Recovered IOA error
Explanation: I/O processor Licensed Internal Code Failing Item:
error v FCIOA
Failing Item: v ANYBRDG
v AJDGP01 v OPT_CLN
v FCIOA
v IOP
v OPT_CLN
27878155 27878155
Explanation: A permanent I/O processor failure
occurred
Failing Item:
v AJDGP01
v FCIOA
v OPT_CLN
27878156 27878156
Explanation: A permanent I/O processor failure
occurred
Failing Item:
v AJDGP01
v FCIOA
v OPT_CLN
27879091 27879091
Explanation: Incorrect hardware configuration change
has been detected.
Response: Reset the I/O processor and then IPL the
I/O processor. For information about how to reset and
IPL the I/O processor, see Debug the resource. If an
I/O processor reset and I/O processor IPL does not
resolve the problem, contact your next level of support.
Failing Item:
v SVCDOCS
27879092 27879092
Explanation: Incorrect hardware configuration change
has been detected.
Response: Reset the I/O processor and then IPL the
I/O processor. For information about how to reset and
2793B940 2793B940
Explanation: I/O adapter hardware error detected
Failing Item:
v FI00719
v AJDGP01
v MA_BRDG
2793B941 2793B941
Explanation: One of the ports on the IOA has failed.
Failing Item:
v FI00719
v AJDGP01
2805B940 2805B940
Explanation: I/O adapter hardware error detected
Failing Item:
v FI00719
v AJDGP01
v MA_BRDG
2805B941 2805B941
Explanation: One of the ports on the IOA has failed.
Failing Item:
v FI00719
v AJDGP01
Explanation: A permanent I/O processor failure IPL the I/O processor, see Debug the resource. If an
occurred I/O processor reset and I/O processor IPL does not
resolve the problem, contact your next level of support.
Failing Item:
v FCIOA Failing Item:
v ANYBRDG v SVCDOCS
v OPT_CLN
280DFF3D 280DFF3D
280D8151 280D8151 Explanation: Recovered IOA error
Explanation: I/O processor Licensed Internal Code Failing Item:
error v FCIOA
Failing Item: v ANYBRDG
v AJDGP01 v OPT_CLN
v FCIOA
v IOP
v OPT_CLN
280D8155 280D8155
Explanation: A permanent I/O processor failure
occurred
Failing Item:
v AJDGP01
v FCIOA
v OPT_CLN
280D8156 280D8156
Explanation: A permanent I/O processor failure
occurred
Failing Item:
v AJDGP01
v FCIOA
v OPT_CLN
280D9091 280D9091
Explanation: Incorrect hardware configuration change
has been detected.
Response: Reset the I/O processor and then IPL the
I/O processor. For information about how to reset and
IPL the I/O processor, see Debug the resource. If an
I/O processor reset and I/O processor IPL does not
resolve the problem, contact your next level of support.
Failing Item:
v SVCDOCS
280D9092 280D9092
Explanation: Incorrect hardware configuration change
has been detected.
Response: Reset the I/O processor and then IPL the
I/O processor. For information about how to reset and
Explanation: A permanent I/O processor failure IPL the I/O processor, see Debug the resource. If an
occurred I/O processor reset and I/O processor IPL does not
resolve the problem, contact your next level of support.
Failing Item:
v FCIOA Failing Item:
v ANYBRDG v SVCDOCS
v OPT_CLN
280EFF3D 280EFF3D
280E8151 280E8151 Explanation: Recovered IOA error
Explanation: I/O processor Licensed Internal Code Failing Item:
error v FCIOA
Failing Item: v ANYBRDG
v AJDGP01 v OPT_CLN
v FCIOA
v IOP
v OPT_CLN
280E8155 280E8155
Explanation: A permanent I/O processor failure
occurred
Failing Item:
v AJDGP01
v FCIOA
v OPT_CLN
280E8156 280E8156
Explanation: A permanent I/O processor failure
occurred
Failing Item:
v AJDGP01
v FCIOA
v OPT_CLN
280E9091 280E9091
Explanation: Incorrect hardware configuration change
has been detected.
Response: Reset the I/O processor and then IPL the
I/O processor. For information about how to reset and
IPL the I/O processor, see Debug the resource. If an
I/O processor reset and I/O processor IPL does not
resolve the problem, contact your next level of support.
Failing Item:
v SVCDOCS
280E9092 280E9092
Explanation: Incorrect hardware configuration change
has been detected.
Response: Reset the I/O processor and then IPL the
I/O processor. For information about how to reset and
2838B930 2838B930
Explanation: I/O adapter Licensed Internal Code
failed
Failing Item:
v AJDGP01
v FI00718
v FI00719
2838B931 2838B931
Explanation: I/O adapter hardware error detected
Failing Item:
v FI00719
v FI00718
v AJDGP01
v MA_BRDG
2838B933 2838B933
Explanation: Incompatible hardware detected.
Failing Item:
v FI00719
v AJDGP01
283C8401 283C8401
Explanation: Removable media power fault
Failing Item:
v DEVBPLN
283C8404 283C8404
Explanation: System log entry only, no service action
required
283CFFF4 283CFFF4
Explanation: Device backplane problem
Failing Item:
v DEVBPLN
v STORIOA
v FI01140
v FI01106
283D8401 283D8401
Explanation: Removable media power fault
Failing Item:
v DEVBPLN
283D8404 283D8404
Explanation: System log entry only, no service action
required
283DFFF4 283DFFF4
Explanation: Device backplane problem
Failing Item:
v DEVBPLN
v STORIOA
v FI01140
v FI01106
v AJDGP01 v USER
v IOP v FI01105
v FI01104
v BACKPLN 28422202 28422202
Explanation: Removable media error during IPL
28421307 28421307 Failing Item:
Explanation: I/O processor resource not available v FI00022
Failing Item: v FI01105
v AJDGP01
v AJDG301 28423000 28423000
Explanation: A permanent I/O processor failure
28421310 28421310 occurred
v FI01101 v IOPIP17
v IOP v USER
v MA_BRDG v FI01107
v STORIOA
28423001 28423001
Explanation: Not valid condition in I/O Processor 28423022 28423022
Licensed Internal Code Explanation: I/O processor detected a SCSI bus
Response: The Licensed Internal Code found a configuration error
condition that should not have occurred. Response: Error occurred on SCSI bus 2.
Failing Item: Failing Item:
v IOP v IOPIP17
v AJDGP01 v USER
v FI01107
28423002 28423002 v STORIOA
Explanation: Addressed device failed to respond to
selection 28423023 28423023
Failing Item: Explanation: I/O processor detected a SCSI bus
v IOPIP16 configuration error
v FI01105 Response: Error occurred on SCSI bus 3.
v STORIOA
Failing Item:
v FI01140
v IOPIP17
v FI01141
v USER
v FI01106
v FI01107
v STORIOA
28423006 28423006
Explanation: System bus error 28423080 28423080
Failing Item: Explanation: I/O processor Licensed Internal Code
v IOP error
v ANYBUS Failing Item:
v FI01101 v AJDGP01
Failing Item:
28423102 28423102
28423120 28423120
Explanation: I/O processor card detected interface
error Explanation: I/O Processor detected that the bus is
not operational
Response: Error occurred on SCSI bus 2.
Response: A device was added to SCSI bus 0 of the
Failing Item: I/O Adapter and caused the bus to become not
v IOPIP13 operational. Remove the device.
v FI01107 Failing Item:
v STORIOA v SVCDOCS
v FI01140
v DEVBPLN 28423121 28423121
Explanation: I/O Processor detected that the bus is
not operational
Response: A device was added to SCSI bus 1 of the
I/O Adapter and caused the bus to become not
Explanation: I/O Processor detected that the bus is Response: This reference code and the 3123 reference
not operational code that occurred before it require no service action,
since SCSI bus 3 is now operational.
Response: A device was added to SCSI bus 2 of the
I/O Adapter and caused the bus to become not
operational. Remove the device. 28423150 28423150
Explanation: I/O Processor detected that the bus is Explanation: Disk media format bad
now operational Failing Item:
Response: This reference code and the 3121 reference v FI01105
code that occurred before it require no service action,
since SCSI bus 1 is now operational.
28423205 28423205
Explanation: Disk sector read error
28423142 28423142
Response: Disk unit data may need to be reloaded,
Explanation: I/O Processor detected that the bus is
but the disk unit does not need to be replaced.
now operational
Failing Item:
Response: This reference code and the 3122 reference
code that occurred before it require no service action, v FI01105
28423250 28423250
28426070 28426070
Explanation: Disk unit requires initialization before
use. Explanation: A permanent I/O processor failure
occurred
Response: Perform a D-IPL and work on errors found
in the log. Failing Item:
v IOP
Failing Item:
v USER
28426071 28426071
28426075 28426075
28423401 28423401
Explanation: I/O processor resource not available
Explanation: Device backplane problem
Failing Item:
Failing Item:
v AJDGP01
v DEVBPLN
28426076 28426076
28423501 28423501
Explanation: I/O processor card detected media error
Explanation: I/O processor Licensed Internal Code
error Failing Item:
Failing Item: v MEDIA
v AJDGP01 v AJDGP01
v IOP v FI01105
Response: No action required. Protection will be Explanation: IOP resources not available due to
automatically restarted. previous problems.
Response: Power off the system and remove all new
28429041 28429041 or replacement disk units. IPL the system to DST. If
you cannot perform a type A or B IPL, perform a type
Explanation: Background array parity check detected D IPL from removable media.
and corrected errors
Look for Product Activity Log entries for other IOP
Response: Call your next level of support to report reference codes and take action on them.
the problem.
Failing Item:
Failing Item:
v SVCDOCS
v AJDGP01
28429081 28429081
28429050 28429050
Explanation: I/O processor card detected device error
Explanation: Required cache data cannot be located
for a disk unit. Failing Item:
v FI01105
Failing Item:
v STORIOA
v IOPIP30
v IOP
2842BE00 2842BE00
Explanation: I/O processor detected a fault condition
2842B3E0 2842B3E0
Failing Item:
Explanation: I/O processor detected a fault condition
v AJDGP01
Failing Item:
v IOP
v IOP
v FI01104
v MA_BRDG
v MA_BRDG
2842B3E1 2842B3E1
2842FF3D 2842FF3D
Explanation: I/O processor detected a fault condition
Explanation: I/O adapter detected recoverable error
Failing Item:
Failing Item:
v IOP
v STORIOA
v MA_BRDG
v ANYBRDG
2842B410 2842B410
2842FF6D 2842FF6D
Explanation: A permanent I/O processor failure
Explanation: I/O processor detected a recoverable
occurred
system bus error
Failing Item:
Failing Item:
v STORIOA
v IOP
v ANYBUS
2842B411 2842B411
Explanation: A permanent I/O processor failure
occurred
Failing Item:
v STORIOA
2842B412 2842B412
Explanation: Tape/CD or disk bus interface error
occurred
Failing Item:
v IOPIP16
v FI01107
v FI01140
v STORIOA
v DEVTERM
2842B935 2842B935
Explanation: Unknown hardware detected
Failing Item:
v FI01101
v AJDGP01
v IOP
v MA_BRDG
v AJDGP01 v USER
v IOP v FI01105
v FI01104
v BACKPLN 28432202 28432202
Explanation: Removable media error during IPL
28431307 28431307 Failing Item:
Explanation: I/O processor resource not available v FI00022
Failing Item: v FI01105
v AJDGP01
v AJDG301 28433000 28433000
Explanation: A permanent I/O processor failure
28431310 28431310 occurred
v FI01101 v IOPIP17
v IOP v USER
v MA_BRDG v FI01107
v STORIOA
28433001 28433001
Explanation: Not valid condition in I/O Processor 28433022 28433022
Licensed Internal Code Explanation: I/O processor detected a SCSI bus
Response: The Licensed Internal Code found a configuration error
condition that should not have occurred. Response: Error occurred on SCSI bus 2.
Failing Item: Failing Item:
v IOP v IOPIP17
v AJDGP01 v USER
v FI01107
28433002 28433002 v STORIOA
Explanation: Addressed device failed to respond to
selection 28433023 28433023
Failing Item: Explanation: I/O processor detected a SCSI bus
v IOPIP16 configuration error
v FI01105 Response: Error occurred on SCSI bus 3.
v STORIOA
Failing Item:
v FI01140
v IOPIP17
v FI01141
v USER
v FI01106
v FI01107
v STORIOA
28433006 28433006
Explanation: System bus error 28433080 28433080
Failing Item: Explanation: I/O processor Licensed Internal Code
v IOP error
v ANYBUS Failing Item:
v FI01101 v AJDGP01
Failing Item:
28433102 28433102
28433120 28433120
Explanation: I/O processor card detected interface
error Explanation: I/O Processor detected that the bus is
not operational
Response: Error occurred on SCSI bus 2.
Response: A device was added to SCSI bus 0 of the
Failing Item: I/O Adapter and caused the bus to become not
v IOPIP13 operational. Remove the device.
v FI01107 Failing Item:
v STORIOA v SVCDOCS
v FI01140
v DEVBPLN 28433121 28433121
Explanation: I/O Processor detected that the bus is
not operational
Response: A device was added to SCSI bus 1 of the
I/O Adapter and caused the bus to become not
Explanation: I/O Processor detected that the bus is Response: This reference code and the 3123 reference
not operational code that occurred before it require no service action,
since SCSI bus 3 is now operational.
Response: A device was added to SCSI bus 2 of the
I/O Adapter and caused the bus to become not
operational. Remove the device. 28433150 28433150
Explanation: I/O Processor detected that the bus is Explanation: Disk media format bad
now operational Failing Item:
Response: This reference code and the 3121 reference v FI01105
code that occurred before it require no service action,
since SCSI bus 1 is now operational.
28433205 28433205
Explanation: Disk sector read error
28433142 28433142
Response: Disk unit data may need to be reloaded,
Explanation: I/O Processor detected that the bus is
but the disk unit does not need to be replaced.
now operational
Failing Item:
Response: This reference code and the 3122 reference
code that occurred before it require no service action, v FI01105
28433250 28433250
28436070 28436070
Explanation: Disk unit requires initialization before
use. Explanation: A permanent I/O processor failure
occurred
Response: Perform a D-IPL and work on errors found
in the log. Failing Item:
v IOP
Failing Item:
v USER
28436071 28436071
28436075 28436075
28433401 28433401
Explanation: I/O processor resource not available
Explanation: Device backplane problem
Failing Item:
Failing Item:
v AJDGP01
v DEVBPLN
28436076 28436076
28433501 28433501
Explanation: I/O processor card detected media error
Explanation: I/O processor Licensed Internal Code
error Failing Item:
Failing Item: v MEDIA
v AJDGP01 v AJDGP01
v IOP v FI01105
Response: No action required. Protection will be Explanation: IOP resources not available due to
automatically restarted. previous problems.
Response: Power off the system and remove all new
28439041 28439041 or replacement disk units. IPL the system to DST. If
you cannot perform a type A or B IPL, perform a type
Explanation: Background array parity check detected D IPL from removable media.
and corrected errors
Look for Product Activity Log entries for other IOP
Response: Call your next level of support to report reference codes and take action on them.
the problem.
Failing Item:
Failing Item:
v SVCDOCS
v AJDGP01
28439081 28439081
28439050 28439050
Explanation: I/O processor card detected device error
Explanation: Required cache data cannot be located
for a disk unit. Failing Item:
v FI01105
Failing Item:
v STORIOA
v IOPIP30
v IOP
2843BE00 2843BE00
Explanation: I/O processor detected a fault condition
2843B3E0 2843B3E0
Failing Item:
Explanation: I/O processor detected a fault condition
v AJDGP01
Failing Item:
v IOP
v IOP
v FI01104
v MA_BRDG
v MA_BRDG
2843B3E1 2843B3E1
2843FF3D 2843FF3D
Explanation: I/O processor detected a fault condition
Explanation: I/O adapter detected recoverable error
Failing Item:
Failing Item:
v IOP
v STORIOA
v MA_BRDG
v ANYBRDG
2843B410 2843B410
2843FF6D 2843FF6D
Explanation: A permanent I/O processor failure
Explanation: I/O processor detected a recoverable
occurred
system bus error
Failing Item:
Failing Item:
v STORIOA
v IOP
v ANYBUS
2843B411 2843B411
Explanation: A permanent I/O processor failure
occurred
Failing Item:
v STORIOA
2843B412 2843B412
Explanation: Tape/CD or disk bus interface error
occurred
Failing Item:
v IOPIP16
v FI01107
v FI01140
v STORIOA
v DEVTERM
2843B935 2843B935
Explanation: Unknown hardware detected
Failing Item:
v FI01101
v AJDGP01
v IOP
v MA_BRDG
v AJDGP01 v USER
v IOP v FI01105
v FI01104
v BACKPLN 28442202 28442202
Explanation: Removable media error during IPL
28441307 28441307 Failing Item:
Explanation: I/O processor resource not available v FI00022
Failing Item: v FI01105
v AJDGP01
v AJDG301 28443000 28443000
Explanation: A permanent I/O processor failure
28441310 28441310 occurred
v FI01101 v IOPIP17
v IOP v USER
v MA_BRDG v FI01107
v STORIOA
28443001 28443001
Explanation: Not valid condition in I/O Processor 28443022 28443022
Licensed Internal Code Explanation: I/O processor detected a SCSI bus
Response: The Licensed Internal Code found a configuration error
condition that should not have occurred. Response: Error occurred on SCSI bus 2.
Failing Item: Failing Item:
v IOP v IOPIP17
v AJDGP01 v USER
v FI01107
28443002 28443002 v STORIOA
Explanation: Addressed device failed to respond to
selection 28443023 28443023
Failing Item: Explanation: I/O processor detected a SCSI bus
v IOPIP16 configuration error
v FI01105 Response: Error occurred on SCSI bus 3.
v STORIOA
Failing Item:
v FI01140
v IOPIP17
v FI01141
v USER
v FI01106
v FI01107
v STORIOA
28443006 28443006
Explanation: System bus error 28443080 28443080
Failing Item: Explanation: I/O processor Licensed Internal Code
v IOP error
v ANYBUS Failing Item:
v FI01101 v AJDGP01
Failing Item:
28443102 28443102
28443120 28443120
Explanation: I/O processor card detected interface
error Explanation: I/O Processor detected that the bus is
not operational
Response: Error occurred on SCSI bus 2.
Response: A device was added to SCSI bus 0 of the
Failing Item: I/O Adapter and caused the bus to become not
v IOPIP13 operational. Remove the device.
v FI01107 Failing Item:
v STORIOA v SVCDOCS
v FI01140
v DEVBPLN 28443121 28443121
Explanation: I/O Processor detected that the bus is
not operational
Response: A device was added to SCSI bus 1 of the
I/O Adapter and caused the bus to become not
Explanation: I/O Processor detected that the bus is Response: This reference code and the 3123 reference
not operational code that occurred before it require no service action,
since SCSI bus 3 is now operational.
Response: A device was added to SCSI bus 2 of the
I/O Adapter and caused the bus to become not
operational. Remove the device. 28443150 28443150
Explanation: I/O Processor detected that the bus is Explanation: Disk media format bad
now operational Failing Item:
Response: This reference code and the 3121 reference v FI01105
code that occurred before it require no service action,
since SCSI bus 1 is now operational.
28443205 28443205
Explanation: Disk sector read error
28443142 28443142
Response: Disk unit data may need to be reloaded,
Explanation: I/O Processor detected that the bus is
but the disk unit does not need to be replaced.
now operational
Failing Item:
Response: This reference code and the 3122 reference
code that occurred before it require no service action, v FI01105
28443250 28443250
28446070 28446070
Explanation: Disk unit requires initialization before
use. Explanation: A permanent I/O processor failure
occurred
Response: Perform a D-IPL and work on errors found
in the log. Failing Item:
v IOP
Failing Item:
v USER
28446071 28446071
28446075 28446075
28443401 28443401
Explanation: I/O processor resource not available
Explanation: Device backplane problem
Failing Item:
Failing Item:
v AJDGP01
v DEVBPLN
28446076 28446076
28443501 28443501
Explanation: I/O processor card detected media error
Explanation: I/O processor Licensed Internal Code
error Failing Item:
Failing Item: v MEDIA
v AJDGP01 v AJDGP01
v IOP v FI01105
Response: No action required. Protection will be Explanation: IOP resources not available due to
automatically restarted. previous problems.
Response: Power off the system and remove all new
28449041 28449041 or replacement disk units. IPL the system to DST. If
you cannot perform a type A or B IPL, perform a type
Explanation: Background array parity check detected D IPL from removable media.
and corrected errors
Look for Product Activity Log entries for other IOP
Response: Call your next level of support to report reference codes and take action on them.
the problem.
Failing Item:
Failing Item:
v SVCDOCS
v AJDGP01
28449081 28449081
28449050 28449050
Explanation: I/O processor card detected device error
Explanation: Required cache data cannot be located
for a disk unit. Failing Item:
v FI01105
Failing Item:
v STORIOA
v IOPIP30
v IOP
2844BE00 2844BE00
Explanation: I/O processor detected a fault condition
2844B3E0 2844B3E0
Failing Item:
Explanation: I/O processor detected a fault condition
v AJDGP01
Failing Item:
v IOP
v IOP
v FI01104
v MA_BRDG
v MA_BRDG
2844B3E1 2844B3E1
2844FF3D 2844FF3D
Explanation: I/O processor detected a fault condition
Explanation: I/O adapter detected recoverable error
Failing Item:
Failing Item:
v IOP
v STORIOA
v MA_BRDG
v ANYBRDG
2844B410 2844B410
2844FF6D 2844FF6D
Explanation: A permanent I/O processor failure
Explanation: I/O processor detected a recoverable
occurred
system bus error
Failing Item:
Failing Item:
v STORIOA
v IOP
v ANYBUS
2844B411 2844B411
Explanation: A permanent I/O processor failure
occurred
Failing Item:
v STORIOA
2844B412 2844B412
Explanation: Tape/CD or disk bus interface error
occurred
Failing Item:
v IOPIP16
v FI01107
v FI01140
v STORIOA
v DEVTERM
2844B935 2844B935
Explanation: Unknown hardware detected
Failing Item:
v FI01101
v AJDGP01
v IOP
v MA_BRDG
v OPT_CLN
28473501 28473501
Explanation: I/O processor Licensed Internal Code
28473087 28473087
error
Explanation: I/O processor resource not available
Failing Item:
Response: The Licensed Internal Code could not v AJDGP01
allocate resources on the I/O processor card.
v IOP
Failing Item:
v AJDGP01 28476070 28476070
v AJDG301
Explanation: A permanent I/O processor failure
v FCIOA occurred
v OPT_CLN
Failing Item:
v IOP
28473100 28473100
Explanation: I/O processor card detected interface 28476071 28476071
error
Explanation: I/O processor Licensed Internal Code
Failing Item: error
v FCINTF
Failing Item:
v ANYFC
v AJDGP01
v FCIOA
v OPT_CLN
28476072 28476072
Explanation: I/O processor Licensed Internal Code
28473109 28473109
error
Explanation: I/O processor timed out a device
Failing Item:
command
v AJDGP01
Failing Item:
v IOP
v FCDEV
v FCINTF
28476075 28476075
v FCIOA
Explanation: I/O processor resource not available
v OPT_CLN
Failing Item:
28473120 28473120 v AJDGP01
v ANYBRDG
28476082 28476082
v OPT_CLN
Explanation: I/O processor Licensed Internal Code
error
28478155 28478155
Failing Item:
Explanation: A permanent I/O processor failure
v AJDGP01
occurred
v IOP
Failing Item:
v AJDGP01
28476083 28476083
v FCIOA
Explanation: I/O processor Licensed Internal Code
v OPT_CLN
error
Failing Item:
28478156 28478156
v AJDGP01
Explanation: A permanent I/O processor failure
v IOP
occurred
Failing Item:
28476085 28476085
v AJDGP01
Explanation: I/O processor Licensed Internal Code
v FCIOA
error
v OPT_CLN
Failing Item:
v AJDGP01
28478200 28478200
v IOP
Explanation: I/O processor Licensed Internal Code
v MA_BRDG
error
Failing Item:
28476200 28476200
v AJDGP01
Explanation: A permanent IOA hardware error
v IOP
occurred
Failing Item:
28478300 28478300
v FCIOA
Explanation: I/O processor card or Licensed Internal
v OPT_CLN
Code error
Response: A microprocessor exception occurred on the
28476201 28476201
I/O processor.
Explanation: IOA LID is not valid
Failing Item:
Failing Item: v FCIOA
v AJDGP01 v IOP
v AJDGP01
28478100 28478100 v OPT_CLN
Explanation: I/O processor Licensed Internal Code
error 28478301 28478301
Failing Item: Explanation: Not valid condition in I/O Processor
v AJDGP01 Licensed Internal Code
v IOP Response: The Licensed Internal Code found a
condition that should not have occurred.
28478150 28478150 Failing Item:
Explanation: A permanent I/O processor failure v FCIOA
occurred v AJDGP01
Failing Item: v IOP
v FCIOA v OPT_CLN
v IOP
2847B3B1 2847B3B1
Explanation: A permanent I/O processor failure
2847B3E0 2847B3E0
occurred
Explanation: I/O processor detected a fault condition
Failing Item:
v IOP Failing Item:
v IOP
2847B3B2 2847B3B2 v MA_BRDG
2847B3B7 2847B3B7
Explanation: A permanent I/O processor failure
occurred
Failing Item:
v IOP
2847B3B8 2847B3B8
Explanation: Multi-adapter Bridge error detected
Failing Item:
v MA_BRDG
2849B930 2849B930
Explanation: I/O adapter Licensed Internal Code
failed
Failing Item:
v AJDGP01
v FI00718
v FI00719
2849B931 2849B931
Explanation: I/O adapter hardware error detected
Failing Item:
v FI00719
v FI00718
v AJDGP01
v MA_BRDG
2849B933 2849B933
Explanation: Incompatible hardware detected.
Failing Item:
v FI00719
v AJDGP01
v AJDGP01 v USER
v IOP v FI01105
v FI01104
v BACKPLN 284B2202 284B2202
Explanation: Removable media error during IPL
284B1307 284B1307 Failing Item:
Explanation: I/O processor resource not available v FI00022
Failing Item: v FI01105
v AJDGP01
v AJDG301 284B3000 284B3000
Explanation: A permanent I/O processor failure
284B1310 284B1310 occurred
v FI01101 v IOPIP17
v IOP v USER
v MA_BRDG v FI01107
v STORIOA
284B3001 284B3001
Explanation: Not valid condition in I/O Processor 284B3022 284B3022
Licensed Internal Code Explanation: I/O processor detected a SCSI bus
Response: The Licensed Internal Code found a configuration error
condition that should not have occurred. Response: Error occurred on SCSI bus 2.
Failing Item: Failing Item:
v IOP v IOPIP17
v AJDGP01 v USER
v FI01107
284B3002 284B3002 v STORIOA
Explanation: Addressed device failed to respond to
selection 284B3023 284B3023
Failing Item: Explanation: I/O processor detected a SCSI bus
v IOPIP16 configuration error
v FI01105 Response: Error occurred on SCSI bus 3.
v STORIOA
Failing Item:
v FI01140
v IOPIP17
v FI01141
v USER
v FI01106
v FI01107
v STORIOA
284B3006 284B3006
Explanation: System bus error 284B3080 284B3080
Failing Item: Explanation: I/O processor Licensed Internal Code
v IOP error
v ANYBUS Failing Item:
v FI01101 v AJDGP01
Failing Item:
284B3102 284B3102
284B3120 284B3120
Explanation: I/O processor card detected interface
error Explanation: I/O Processor detected that the bus is
not operational
Response: Error occurred on SCSI bus 2.
Response: A device was added to SCSI bus 0 of the
Failing Item: I/O Adapter and caused the bus to become not
v IOPIP13 operational. Remove the device.
v FI01107 Failing Item:
v STORIOA v SVCDOCS
v FI01140
v DEVBPLN 284B3121 284B3121
Explanation: I/O Processor detected that the bus is
not operational
Response: A device was added to SCSI bus 1 of the
I/O Adapter and caused the bus to become not
Explanation: I/O Processor detected that the bus is Response: This reference code and the 3123 reference
not operational code that occurred before it require no service action,
since SCSI bus 3 is now operational.
Response: A device was added to SCSI bus 2 of the
I/O Adapter and caused the bus to become not
operational. Remove the device. 284B3150 284B3150
Explanation: I/O Processor detected that the bus is Explanation: Disk media format bad
now operational Failing Item:
Response: This reference code and the 3121 reference v FI01105
code that occurred before it require no service action,
since SCSI bus 1 is now operational.
284B3205 284B3205
Explanation: Disk sector read error
284B3142 284B3142
Response: Disk unit data may need to be reloaded,
Explanation: I/O Processor detected that the bus is
but the disk unit does not need to be replaced.
now operational
Failing Item:
Response: This reference code and the 3122 reference
code that occurred before it require no service action, v FI01105
284B3250 284B3250
284B6070 284B6070
Explanation: Disk unit requires initialization before
use. Explanation: A permanent I/O processor failure
occurred
Response: Perform a D-IPL and work on errors found
in the log. Failing Item:
v IOP
Failing Item:
v USER
284B6071 284B6071
284B6075 284B6075
284B3401 284B3401
Explanation: I/O processor resource not available
Explanation: Device backplane problem
Failing Item:
Failing Item:
v AJDGP01
v DEVBPLN
284B6076 284B6076
284B3501 284B3501
Explanation: I/O processor card detected media error
Explanation: I/O processor Licensed Internal Code
error Failing Item:
Failing Item: v MEDIA
v AJDGP01 v AJDGP01
v IOP v FI01105
Response: No action required. Protection will be Explanation: IOP resources not available due to
automatically restarted. previous problems.
Response: Power off the system and remove all new
284B9041 284B9041 or replacement disk units. IPL the system to DST. If
you cannot perform a type A or B IPL, perform a type
Explanation: Background array parity check detected D IPL from removable media.
and corrected errors
Look for Product Activity Log entries for other IOP
Response: Call your next level of support to report reference codes and take action on them.
the problem.
Failing Item:
Failing Item:
v SVCDOCS
v AJDGP01
284B9081 284B9081
284B9050 284B9050
Explanation: I/O processor card detected device error
Explanation: Required cache data cannot be located
for a disk unit. Failing Item:
v FI01105
Failing Item:
v STORIOA
v IOPIP30
v IOP
284BBE00 284BBE00
Explanation: I/O processor detected a fault condition
284BB3E0 284BB3E0
Failing Item:
Explanation: I/O processor detected a fault condition
v AJDGP01
Failing Item:
v IOP
v IOP
v FI01104
v MA_BRDG
v MA_BRDG
284BB3E1 284BB3E1
284BFF3D 284BFF3D
Explanation: I/O processor detected a fault condition
Explanation: I/O adapter detected recoverable error
Failing Item:
Failing Item:
v IOP
v STORIOA
v MA_BRDG
v ANYBRDG
284BB410 284BB410
284BFF6D 284BFF6D
Explanation: A permanent I/O processor failure
Explanation: I/O processor detected a recoverable
occurred
system bus error
Failing Item:
Failing Item:
v STORIOA
v IOP
v ANYBUS
284BB411 284BB411
Explanation: A permanent I/O processor failure
occurred
Failing Item:
v STORIOA
284BB412 284BB412
Explanation: Tape/CD or disk bus interface error
occurred
Failing Item:
v IOPIP16
v FI01107
v FI01140
v STORIOA
v DEVTERM
284BB935 284BB935
Explanation: Unknown hardware detected
Failing Item:
v FI01101
v AJDGP01
v IOP
v MA_BRDG
28758404 28758404
Explanation: System log entry only, no service action
required
2875FFF4 2875FFF4
Explanation: Device backplane problem
Failing Item:
v SASEXP
v SASCABL
v STORIOA
v DEVBPLN
28768404 28768404
Explanation: System log entry only, no service action
required
2876FFF4 2876FFF4
Explanation: Device backplane problem
Failing Item:
v SASEXP
v SASCABL
v STORIOA
v DEVBPLN
Explanation: I/O adapter resource not available. Explanation: A permanent I/O processor failure
occurred
Failing Item:
Failing Item:
v AJDGP01
v AJDGP01
v IOP
28906083 28906083
Explanation: I/O adapter Licensed Internal Code
28906223 28906223
failed.
Explanation: A permanent I/O processor failure
Failing Item:
occurred
v AJDGP01
Failing Item:
v IOP
v IOP
v AJDGP01
28906085 28906085
Explanation: I/O adapter Licensed Internal Code
28906224 28906224
failed.
Explanation: A permanent I/O processor failure
Failing Item:
occurred
v AJDGP01
Failing Item:
v IOP
v DISKIMG
v MA_BRDG
v AJDGP01
v IOP
28906201 28906201
v MEMORY
Explanation: A permanent I/O processor failure
occurred
28906225 28906225
Failing Item:
Explanation: A permanent I/O processor failure
v IOP
occurred
v AJDGP01
Failing Item:
v AJDGP01
28906202 28906202
v AJDG301
Explanation: I/O processor Licensed Internal Code
v IOP
error
Failing Item:
28906226 28906226
v AJDGP01
Explanation: I/O processor card detected device error
v IOP
Failing Item:
v AJDG301
v AS4NTDD v AJDGP01
v AS4NTDD
28906227 28906227
Explanation: A HostLAN error was detected 28906533 28906533
Failing Item:
28906538 28906538
v AJDGP01
v IOP Explanation: A Virtual SCSI error was detected.
Failing Item:
28906530 28906530 v NTVSCSI
Explanation: A Virtual SCSI error was detected. v NTOPSYS
Failing Item:
28906539 28906539
v NTVSCSI
v NTOPSYS Explanation: A Virtual SCSI error was detected.
Failing Item:
28906531 28906531 v NTVSCSI
Explanation: A Virtual SCSI error was detected. v AS4NTDD
v NTOPSYS
Failing Item:
v AJDGP01
v NTVSCSI
v AS4NTDD
2890653A 2890653A
v NTOPSYS
v AJDGP01 Explanation: A Virtual SCSI error was detected.
Failing Item:
28906532 28906532 v NTOPSYS
Explanation: A Virtual SCSI error was detected. v AJDGP01
v AS4NTDD
Failing Item:
v NTOPSYS
v IOP
2890B3B1 2890B3B1
Explanation: A permanent I/O processor failure
2890B3B9 2890B3B9
occurred
Explanation: A permanent I/O processor failure
Failing Item:
occurred
v IOP
Failing Item:
v IOP
2890B3B2 2890B3B2
Explanation: A permanent I/O processor failure
2890B3E0 2890B3E0
occurred
Explanation: I/O processor detected a fault condition
Failing Item:
v IOP Failing Item:
v IOP
2890B3B3 2890B3B3 v MA_BRDG
Explanation: Multi-adapter bridge error detected. Explanation: I/O adapter hardware error detected
v IOA v MA_BRDG
v MEMORY
2890B960 2890B960
2890B4B5 2890B4B5 Explanation: I/O processor Licensed Internal Code
Explanation: An I/O adapter failure occurred. error
2890B4BE 2890B4BE
Explanation: Adapter card storage error
Failing Item:
v MEMORY
v IOP
2890B904 2890B904
Explanation: A permanent I/O processor failure
occurred
Failing Item:
v AJDGP01
v IOP
2890B935 2890B935
Explanation: Incompatible hardware detected.
Failing Item:
v IOA
v AJDGP01
v IOP
Explanation: Adapter card storage error Explanation: I/O adapter Licensed Internal Code
failed.
Failing Item:
Failing Item:
v AJDGP01
v IOP
v AJDG301
v AJDGP01
v IOP
v MA_BRDG
28923006 28923006
v AJDGP01
28926201 28926201
v AJDG301
Explanation: A permanent I/O processor failure
v NTUSER
occurred
v IOA
Failing Item:
v IOP
28926070 28926070
v AJDGP01
Explanation: An I/O adapter failure occurred.
Failing Item: 28926202 28926202
v IOP
Explanation: I/O processor Licensed Internal Code
error
28926071 28926071
Failing Item:
Explanation: I/O adapter Licensed Internal Code v AJDGP01
failed.
v IOP
Failing Item:
v AJDGP01 28926204 28926204
Explanation: I/O adapter failure due to a thermal
28926072 28926072 condition
Explanation: I/O adapter Licensed Internal Code Failing Item:
failed.
v IOP
Failing Item:
v AJDGP01 28926210 28926210
v IOP
Explanation: I/O processor Licensed Internal Code
error
28926075 28926075
Failing Item:
Explanation: I/O adapter resource not available. v AJDGP01
Failing Item:
v AJDGP01 28926221 28926221
Explanation: I/O processor resource not available
28926083 28926083
Failing Item:
Explanation: I/O adapter Licensed Internal Code v AJDG301
failed.
Failing Item: 28926222 28926222
v AJDGP01
Explanation: A permanent I/O processor failure
v IOP occurred
Failing Item:
28926085 28926085
v AJDGP01
Explanation: I/O adapter Licensed Internal Code v IOP
failed.
Failing Item: 28926223 28926223
v AJDGP01
Explanation: A permanent I/O processor failure
v IOP occurred
v MA_BRDG
Failing Item:
v IOP
v AJDGP01
28926535 28926535
Explanation: A Virtual SCSI error was detected.
Failing Item:
v NTUSER
v NTDEVDR
2892653F 2892653F
v AJDGP01
Explanation: A Virtual SCSI error was detected.
Failing Item:
2892B3B9 2892B3B9
v IOP
Explanation: A permanent I/O processor failure
occurred
2892B3B2 2892B3B2
Failing Item:
Explanation: A permanent I/O processor failure
occurred v IOP
Failing Item:
2892B3E0 2892B3E0
v IOP
Explanation: I/O processor detected a fault condition
2892B3B3 2892B3B3 Failing Item:
Explanation: A permanent I/O processor failure v IOP
occurred v MA_BRDG
Failing Item:
v IOP 2892B3E1 2892B3E1
Explanation: An I/O adapter failure occurred.
2892B3B4 2892B3B4 Failing Item:
Explanation: A permanent I/O processor failure v IOP
occurred v MA_BRDG
Failing Item:
v IOP
2892BE00 2892BE00
Explanation: An I/O adapter failure occurred.
Failing Item:
v AJDGP01
v IOP
v IOA
v MA_BRDG
28B98401 28B98401
Explanation: Removable media power fault
Failing Item:
v DEVBPLN
28B98404 28B98404
Explanation: System log entry only, no service action
required
28B9FFF4 28B9FFF4
Explanation: Device backplane problem
Failing Item:
v DEVBPLN
v STORIOA
v FI01140
v FI01106
28CB8401 28CB8401
Explanation: Removable media power fault
Failing Item:
v DEVBPLN
28CB8404 28CB8404
Explanation: System log entry only, no service action
required
28CBFFF4 28CBFFF4
Explanation: Device backplane problem
Failing Item:
v DEVBPLN
v STORIOA
v FI01140
v FI01106
28CC8401 28CC8401
Explanation: Removable media power fault
Failing Item:
v DEVBPLN
28CC8404 28CC8404
Explanation: System log entry only, no service action
required
28CCFFF4 28CCFFF4
Explanation: Device backplane problem
Failing Item:
v DEVBPLN
v STORIOA
v FI01140
v FI01106
293C8404 293C8404
Explanation: System log entry only, no service action
required
293CFFF4 293CFFF4
Explanation: Device backplane problem
Failing Item:
v SASEXP
v SASCABL
v STORIOA
v DEVBPLN
293D8404 293D8404
Explanation: System log entry only, no service action
required
293DFFF4 293DFFF4
Explanation: Device backplane problem
Failing Item:
v SASEXP
v SASCABL
v STORIOA
v DEVBPLN
297D8404 297D8404
Explanation: System log entry only, no service action
required
297DFFF4 297DFFF4
Explanation: Device backplane problem
Failing Item:
v SASEXP
v SASCABL
v STORIOA
v DEVBPLN
2A398404 2A398404
Explanation: System log entry only, no service action
required
2A39FFF4 2A39FFF4
Explanation: Device backplane problem
Failing Item:
v SASEXP
v SASCABL
v STORIOA
v DEVBPLN
2B6CB934 2B6CB934
Explanation: Incompatible hardware detected.
Failing Item:
v FI00719
v FI00718
2B6CB940 2B6CB940
Explanation: I/O adapter hardware error detected.
Failing Item:
v FI00719
v FI00718
v AJDGP01
v MA_BRDG
2B6CB941 2B6CB941
Explanation: One half of I/O adapter failed.
Failing Item:
v FI00719
v FI00718
v AJDGP01
2B6CB942 2B6CB942
Explanation: One half of I/O adapter failed.
Failing Item:
v FI00719
v FI00718
v AJDGP01
2BBE8404 2BBE8404
Explanation: System log entry only, no service action
required
2BBEFFF4 2BBEFFF4
Explanation: Device backplane problem
Failing Item:
v SASEXP
v SASCABL
v STORIOA
v DEVBPLN
2BD68404 2BD68404
Explanation: System log entry only, no service action
required
2BD6FFF4 2BD6FFF4
Explanation: Device backplane problem
Failing Item:
v SASEXP
v SASCABL
v STORIOA
v DEVBPLN
2BD88404 2BD88404
Explanation: System log entry only, no service action
required
2BD8FFF4 2BD8FFF4
Explanation: Device backplane problem
Failing Item:
v SASEXP
v SASCABL
v STORIOA
v DEVBPLN
Problem determination: IPL the IOP to retry the Explanation: Incomplete multipath connection
device identification process. If the error persists then
Response: Incomplete multipath connection between
contact your service provider.
device backplane and device.
Failing Item:
Failing Item:
v PTFSRCH
v SIP3146
2BD934FF 2BD934FF
2BD94050 2BD94050
Explanation: Format in progress
Explanation: Enclosure does not support required
Response: No action required. This reference code is multipath function
logged for information only.
Failing Item:
v SIP3148
2BD93601 2BD93601
Explanation: System log entry only. No service action 2BD94060 2BD94060
required.
Explanation: Multipath redundancy level reduced
Response: A redundant disk unit connection has
failed.
Failing Item:
v SIP4153
2BD94150 2BD94150
v SASCABL
Explanation: I/O adapter detected PCI bus error
v SASEXP
Response: If this event appears in a serviceable event
view, work with the failing item list found there. If this
2BD94061 2BD94061
event does not appear in a serviceable event view, no
Explanation: Multipath redundancy level increased service action is required.
Response: A redundant disk unit connection has been If you are working with one of the card types below,
restored. No service action is required. the adapter has mulitple physical parts. Choose the
card type to identify the physical parts of the storage
adapter.
2BD94070 2BD94070
Card type 2BE1 (feature RAID enablement card for
Explanation: System log entry only. No service action embedded IOA) read the following: When working the
required. FRUs from the serviceable event or the failing item list
here, the embedded storage adapter (STORIOA) has
2BD94100 2BD94100 three physical parts:
v The embedded storage adapter on the I/O
Explanation: Device bus fabric error
backplane.
Response: For card type 2BE1 (feature RAID v The RAID enablement card.
enablement card for embedded IOA) read the
v The Battery charger and carrier card.
following: When working the FRUs from the
serviceable event or the failing item list here, the
embedded storage adapter (STORIOA) has three See symbolic FRU FEATCRD for the location codes of
physical parts: the FRUs if they are not listed in the serviceable event
or if you are working the failing item list here.
1. The embedded storage adapter on the I/O
backplane.
Card type 57CB (embedded IOA with 2BCF battery
2. The RAID enablement card. card for embedded IOA) read the following: When
3. The Battery charger and carrier card. working the FRUs from the serviceable event or the
failing item list here, the embedded storage adapter
See symbolic FRU FEATCRD for the location codes of (STORIOA) has two physical parts:
the FRUs if they are not listed in the serviceable event v The embedded storage adapter on the I/O
or if you are working the failing item list here. backplane.
Failing Item: v The Battery charger and carrier card.
v SIP4152
See symbolic FRU FEATCRD for the location codes of
v SASCABL the FRUs if they are not listed in the serviceable event
v SASEXP or if you are working the failing item list here.
v DEVBPLN
v STORIOA Card type 57CF (embedded IOAs on DASD backplane
with 2BC2 dual battery charger and carrier card for the
v FI01105 embedded IOAs) read the following: When working
the FRUs from the serviceable event or the failing item
2BD94101 2BD94101 list here, the embedded storage adapters (STORIOA)
have two physical parts:
Explanation: Temporary device bus fabric error
v The embedded storage adapter on the DASD
Failing Item: backplane.
v SIP4152 v The dual battery charger and carrier card. To
determine which battery is connected to which
embedded IOA use the bus number of the IOA with
2BD94110 2BD94110
symbolic FRU CACHBAT.
Explanation: Unsupported enclosure function detected
See symbolic FRU FEATCRD for the location code of
Failing Item:
the dual battery charger and carrier card if it is not
v SIP3145 listed in the serviceable event or if you are working the
failing item list here.
Failing Item:
See symbolic FRU FEATCRD for the location codes of Card type 57CB (embedded IOA with 2BCF battery
the FRUs if they are not listed in the serviceable event card) read the following: When working the FRUs from
or if you are working the failing item list here. the serviceable event or the failing item list here, the
embedded storage adapter (STORIOA) has two
Card type 57CF (embedded IOAs on DASD backplane physical parts:
with 2BC2 dual battery charger and carrier card for the v The embedded storage adapter on the I/O
embedded IOAs) read the following: When working backplane.
the FRUs from the serviceable event or the failing item
list here, the embedded storage adapters (STORIOA) v The Battery charger and carrier card.
have two physical parts:
See symbolic FRU FEATCRD for the location codes of
v The embedded storage adapter on the DASD
the FRUs if they are not listed in the serviceable event
backplane.
or if you are working the failing item list here.
v The dual battery charger and carrier card. To
determine which battery is connected to which Card type 57CF (embedded IOAs on DASD backplane
embedded IOA use the bus number of the IOA with with 2BC2 dual battery charger and carrier card) read
symbolic FRU CACHBAT. the following: When working the FRUs from the
serviceable event or the failing item list here, the
embedded storage adapters (STORIOA) have two
physical parts:
v The embedded storage adapter on the DASD Card type 57CF (embedded IOAs on DASD backplane
backplane. with 2BC2 dual battery charger and carrier card for the
v The dual battery charger and carrier card. To embedded IOAs) read the following: When working
determine which battery is connected to which the FRUs from the serviceable event or the failing item
embedded IOA use the bus number of the IOA with list here, the embedded storage adapters (STORIOA)
symbolic FRU CACHBAT. have two physical parts:
v The embedded storage adapter on the DASD
See symbolic FRU FEATCRD for the location code of backplane.
the dual battery charger and carrier card if it is not v The dual battery charger and carrier card. To
listed in the serviceable event or if you are working the determine which battery is connected to which
failing item list here. embedded IOA use the bus number of the IOA with
Failing Item: symbolic FRU CACHBAT.
v CACHBAT
See symbolic FRU FEATCRD for the location code of
v STORIOA the dual battery charger and carrier card if it is not
v FEATCRD listed in the serviceable event or if you are working the
failing item list here.
Card type 57CB (embedded IOA with 2BCF battery 2BD98141 2BD98141
card for embedded IOA) read the following: When
working the FRUs from the serviceable event or the Explanation: IOA detected recoverable device error
failing item list here, the embedded storage adapter
Response: No action is required. This reference code
(STORIOA) has two physical parts:
is logged for information only.
v The embedded storage adapter on the I/O
backplane.
2BD98146 2BD98146
v The Battery charger and carrier card.
Explanation: Disk device detected recoverable error
See symbolic FRU FEATCRD for the location codes of
Failing Item:
the FRUs if they are not listed in the serviceable event
or if you are working the failing item list here. v FI01105
See symbolic FRU FEATCRD for the location code of See symbolic FRU FEATCRD for the location code of
the dual battery charger and carrier card if it is not the dual battery charger and carrier card if it is not
listed in the serviceable event or if you are working the listed in the serviceable event or if you are working the
failing item list here. failing item list here.
Failing Item: Failing Item:
v PTFSRCH v PTFSRCH
v STORIOA v STORIOA
See symbolic FRU FEATCRD for the location codes of See symbolic FRU FEATCRD for the location codes of
the FRUs if they are not listed in the serviceable event the FRUs if they are not listed in the serviceable event
or if you are working the failing item list here. or if you are working the failing item list here.
Card type 57CB (embedded IOA with 2BCF battery Card type 57CB (embedded IOA with 2BCF battery
card for embedded IOA) read the following: When card for embedded IOA) read the following: When
working the FRUs from the serviceable event or the working the FRUs from the serviceable event or the
failing item list here, the embedded storage adapter failing item list here, the embedded storage adapter
(STORIOA) has two physical parts: (STORIOA) has two physical parts:
v The embedded storage adapter on the I/O v The embedded storage adapter on the I/O
backplane. backplane.
v The Battery charger and carrier card. v The Battery charger and carrier card.
See symbolic FRU FEATCRD for the location codes of See symbolic FRU FEATCRD for the location codes of
the FRUs if they are not listed in the serviceable event the FRUs if they are not listed in the serviceable event
or if you are working the failing item list here. or if you are working the failing item list here.
Card type 57CF (embedded IOAs on DASD backplane Card type 57CF (embedded IOAs on DASD backplane
with 2BC2 dual battery charger and carrier card for the with 2BC2 dual battery charger and carrier card for the
embedded IOAs) read the following: When working embedded IOAs) read the following: When working
the FRUs from the serviceable event or the failing item the FRUs from the serviceable event or the failing item
list here, the embedded storage adapters (STORIOA) list here, the embedded storage adapters (STORIOA)
have two physical parts: have two physical parts:
v The embedded storage adapter on the DASD v The embedded storage adapter on the DASD
backplane. backplane.
v The dual battery charger and carrier card. To v The dual battery charger and carrier card. To
determine which battery is connected to which determine which battery is connected to which
embedded IOA use the bus number of the IOA with embedded IOA use the bus number of the IOA with
symbolic FRU CACHBAT. symbolic FRU CACHBAT.
See symbolic FRU FEATCRD for the location code of the FRUs from the serviceable event or the failing item
the dual battery charger and carrier card if it is not list here, the embedded storage adapters (STORIOA)
listed in the serviceable event or if you are working the have two physical parts:
failing item list here. v The embedded storage adapter on the DASD
Failing Item: backplane.
v PTFSRCH v The dual battery charger and carrier card. To
determine which battery is connected to which
v STORIOA
embedded IOA use the bus number of the IOA with
symbolic FRU CACHBAT.
2BD98157 2BD98157
See symbolic FRU FEATCRD for the location code of
Explanation: I/O adapter card error
the dual battery charger and carrier card if it is not
Response: The FRU list in the Service Action Log will listed in the serviceable event or if you are working the
vary based on the conditions this event was logged for. failing item list here.
Display the Service Action Log entry for this SRC. If Failing Item:
the Failing Item indicates an I/O adapter, then replace v SVCDOCS
the I/O adapter. If the Failing Item indicates
v STORIOA
SVCDOCS, then do NOT replace the I/O adapter. This
is a recoverable error. Use Hardware Service Manager
to re-IPL the virtual I/O processor that is associated 2BD98300 2BD98300
with this I/O adapter. Other resources attached to the
Explanation: IOA hardware error or PCI bus error
virtual I/O processor may then need to be Varied On.
Response: If you are working with one of the card
If you are replacing the I/O adapter and you are
types below, the adapter has mulitple physical parts.
working with one of the card types below, the adapter
Choose the card type to identify the physical parts of
has mulitple physical parts. Choose the card type to
the storage adapter.
identify the physical parts of the storage adapter.
Card type 2BE1 (feature RAID enablement card for
Card type 2BE1 (feature RAID enablement card for
embedded IOA) read the following: When working the
embedded IOA) read the following: When working the
FRUs from the serviceable event or the failing item list
FRUs from the serviceable event or the failing item list
here, the embedded storage adapter (STORIOA) has
here, the embedded storage adapter (STORIOA) has
three physical parts:
three physical parts:
v The embedded storage adapter on the I/O
v The embedded storage adapter on the I/O
backplane.
backplane.
v The RAID enablement card.
v The RAID enablement card.
v The Battery charger and carrier card.
v The Battery charger and carrier card.
the FRUs from the serviceable event or the failing item embedded IOAs) read the following: When working
list here, the embedded storage adapters (STORIOA) the FRUs from the serviceable event or the failing item
have two physical parts: list here, the embedded storage adapters (STORIOA)
v The embedded storage adapter on the DASD have two physical parts:
backplane. v The embedded storage adapter on the DASD
v The dual battery charger and carrier card. To backplane.
determine which battery is connected to which v The dual battery charger and carrier card. To
embedded IOA use the bus number of the IOA with determine which battery is connected to which
symbolic FRU CACHBAT. embedded IOA use the bus number of the IOA with
symbolic FRU CACHBAT.
See symbolic FRU FEATCRD for the location code of
the dual battery charger and carrier card if it is not See symbolic FRU FEATCRD for the location code of
listed in the serviceable event or if you are working the the dual battery charger and carrier card if it is not
failing item list here. listed in the serviceable event or if you are working the
failing item list here.
Failing Item:
v STORIOA Failing Item:
v ANYBRDG v PTFSRCH
v PTFSRCH v STORIOA
Explanation: Not valid condition in Licensed Internal Explanation: Missing Licensed Internal Code
Code Response: Ensure that the code necessary to support
Response: If you are working with one of the card this I/O adapter is loaded.
types below, the adapter has mulitple physical parts. If you are working with one of the card types below,
Choose the card type to identify the physical parts of the adapter has mulitple physical parts. Choose the
the storage adapter. card type to identify the physical parts of the storage
Card type 2BE1 (feature RAID enablement card for adapter.
embedded IOA) read the following: When working the Card type 2BE1 (feature RAID enablement card for
FRUs from the serviceable event or the failing item list embedded IOA) read the following: When working the
here, the embedded storage adapter (STORIOA) has FRUs from the serviceable event or the failing item list
three physical parts: here, the embedded storage adapter (STORIOA) has
v The embedded storage adapter on the I/O three physical parts:
backplane. v The embedded storage adapter on the I/O
v The RAID enablement card. backplane.
v The Battery charger and carrier card. v The RAID enablement card.
v The Battery charger and carrier card.
See symbolic FRU FEATCRD for the location codes of
the FRUs if they are not listed in the serviceable event See symbolic FRU FEATCRD for the location codes of
or if you are working the failing item list here. the FRUs if they are not listed in the serviceable event
or if you are working the failing item list here.
Card type 57CB (embedded IOA with 2BCF battery
card for embedded IOA) read the following: When Card type 57CB (embedded IOA with 2BCF battery
working the FRUs from the serviceable event or the card for embedded IOA) read the following: When
failing item list here, the embedded storage adapter working the FRUs from the serviceable event or the
(STORIOA) has two physical parts: failing item list here, the embedded storage adapter
v The embedded storage adapter on the I/O (STORIOA) has two physical parts:
backplane. v The embedded storage adapter on the I/O
v The Battery charger and carrier card. backplane.
v The Battery charger and carrier card.
See symbolic FRU FEATCRD for the location codes of
the FRUs if they are not listed in the serviceable event See symbolic FRU FEATCRD for the location codes of
or if you are working the failing item list here. the FRUs if they are not listed in the serviceable event
or if you are working the failing item list here.
Card type 57CF (embedded IOAs on DASD backplane
with 2BC2 dual battery charger and carrier card for the
Card type 57CF (embedded IOAs on DASD backplane failing item list here, the embedded storage adapter
with 2BC2 dual battery charger and carrier card for the (STORIOA) has two physical parts:
embedded IOAs) read the following: When working v The embedded storage adapter on the I/O
the FRUs from the serviceable event or the failing item backplane.
list here, the embedded storage adapters (STORIOA)
v The Battery charger and carrier card.
have two physical parts:
v The embedded storage adapter on the DASD See symbolic FRU FEATCRD for the location codes of
backplane. the FRUs if they are not listed in the serviceable event
v The dual battery charger and carrier card. To or if you are working the failing item list here.
determine which battery is connected to which
embedded IOA use the bus number of the IOA with Card type 57CF (embedded IOAs on DASD backplane
symbolic FRU CACHBAT. with 2BC2 dual battery charger and carrier card for the
embedded IOAs) read the following: When working
See symbolic FRU FEATCRD for the location code of the FRUs from the serviceable event or the failing item
the dual battery charger and carrier card if it is not list here, the embedded storage adapters (STORIOA)
listed in the serviceable event or if you are working the have two physical parts:
failing item list here. v The embedded storage adapter on the DASD
Failing Item: backplane.
v SVCDOCS v The dual battery charger and carrier card. To
determine which battery is connected to which
v STORIOA
embedded IOA use the bus number of the IOA with
symbolic FRU CACHBAT.
2BD98400 2BD98400
See symbolic FRU FEATCRD for the location code of
Explanation: Licensed Internal Code error
the dual battery charger and carrier card if it is not
Failing Item: listed in the serviceable event or if you are working the
v PTFSRCH failing item list here.
Failing Item:
2BD98404 2BD98404 v FI01105
Explanation: System log entry only. No service action v STORIOA
required.
2BD99001 2BD99001
2BD99000 2BD99000 Explanation: Device configuration error
Explanation: Device error Failing Item:
Response: If you are working with one of the card v NEXTLVL
types below, the adapter has mulitple physical parts.
Choose the card type to identify the physical parts of
2BD99002 2BD99002
the storage adapter.
Explanation: Device error
Card type 2BE1 (feature RAID enablement card for
embedded IOA) read the following: When working the Failing Item:
FRUs from the serviceable event or the failing item list v NEXTLVL
here, the embedded storage adapter (STORIOA) has
three physical parts:
v The embedded storage adapter on the I/O 2BD99008 2BD99008
backplane. Explanation: I/O card does not support functions
v The RAID enablement card. expected by devices
v The Battery charger and carrier card. Failing Item:
v SIP3130
See symbolic FRU FEATCRD for the location codes of
the FRUs if they are not listed in the serviceable event
or if you are working the failing item list here. 2BD99010 2BD99010
Explanation: Cache data associated with attached
Card type 57CB (embedded IOA with 2BCF battery devices cannot be found
card for embedded IOA) read the following: When
working the FRUs from the serviceable event or the Failing Item:
v SIP3120
2BD99026 2BD99026
Explanation: Disk unit not found at required physical
2BD99011 2BD99011
location
Explanation: Cache data belongs to devices other than
Response: A previously exposed disk unit in an array
those attached
was not found at the required physical location.
Failing Item:
Failing Item:
v NEXTLVL
v NEXTLVL
2BD99020 2BD99020
2BD99027 2BD99027
Explanation: Two or more disk units missing from
Explanation: Array not functional due to parity out of
RAID-5 or RAID-6 array
synchronization
Failing Item:
Response: Array is or would become exposed and
v SIP3111 parity data is out of synchronization
Failing Item:
2BD99021 2BD99021
v SIP3113
Explanation: Two or more disk units missing from
RAID-5 or RAID-6 array
2BD99028 2BD99028
Failing Item:
Explanation: Maximum number of functional arrays
v SIP3111 has been exceeded
Response: Reduce the number of arrays on this I/O
2BD99022 2BD99022 adapter. Either move all the devices in an array to
Explanation: Two or more disk units missing from another I/O adapter that supports arrays, or stop an
RAID-5 or RAID-6 array array on this I/O adapter.
v SIP3111 v SVCDOCS
Explanation: One or more array members not in Explanation: Maximum number of functional array
required physical locations members has been exceeded
Failing Item:
2BD99032 2BD99032
v NEXTLVL
Explanation: A disk unit in an array is missing or
failed
2BD99054 2BD99054
Response: The array is still protected, but the disk
unit should be replaced. Explanation: IOA resources not available due to
previous problems
Failing Item:
Failing Item:
v SIP3110
v SIP3121
v FI02112
2BD99070 2BD99070
2BD99040 2BD99040
Explanation: System log entry only. No service action
Explanation: Re-synchronization of array parity was
required.
initiated
Response: No action required.
2BD99071 2BD99071
Explanation: Link from IOA to auxiliary or remote
2BD99041 2BD99041
IOA is operational
Explanation: Background array parity check detected
Response: No service action required.
and corrected errors
Response: Call your next level of support to report
2BD99072 2BD99072
the problem.
Explanation: Link from IOA to auxiliary or remote
Failing Item:
IOA is non-operational
v NEXTLVL
Response: No service action required.
2BD99042 2BD99042
2BD99073 2BD99073
Explanation: Background parity check corrected errors
on disk unit Explanation: Multiple I/O adapters connected in a not
valid configuration
Response: Call your next level of support to report
the problem. Failing Item:
v SIP4140
Failing Item:
v NEXTLVL
2BD99074 2BD99074
2BD99051 2BD99051
2BD99075 2BD99075
Explanation: Cache data exists for one or more
missing or failed devices Explanation: Incomplete multipath connection
between IOA and remote IOA
Failing Item:
Failing Item:
v SIP3132
v SIP4149
2BD99052 2BD99052
Explanation: Cache data exists for one or more
modified devices
Response: Contact your next level of support.
Failing Item:
2BD99076 2BD99076
v FI01105
Explanation: Missing auxiliary IOA or remote IOA
v STORIOA
Failing Item:
v SIP4147 2BD99082 2BD99082
Explanation: Device error
2BD99081 2BD99081
Response: If you are working with one of the card
Explanation: Device error types below, the adapter has mulitple physical parts.
Response: If you are working with one of the card Choose the card type to identify the physical parts of
types below, the adapter has mulitple physical parts. the storage adapter.
Choose the card type to identify the physical parts of Card type 2BE1 (feature RAID enablement card for
the storage adapter. embedded IOA) read the following: When working the
Card type 2BE1 (feature RAID enablement card for FRUs from the serviceable event or the failing item list
embedded IOA) read the following: When working the here, the embedded storage adapter (STORIOA) has
FRUs from the serviceable event or the failing item list three physical parts:
here, the embedded storage adapter (STORIOA) has v The embedded storage adapter on the I/O
three physical parts: backplane.
v The embedded storage adapter on the I/O v The RAID enablement card.
backplane. v The Battery charger and carrier card.
v The RAID enablement card.
v The Battery charger and carrier card. See symbolic FRU FEATCRD for the location codes of
the FRUs if they are not listed in the serviceable event
See symbolic FRU FEATCRD for the location codes of or if you are working the failing item list here.
the FRUs if they are not listed in the serviceable event
or if you are working the failing item list here. Card type 57CB (embedded IOA with 2BCF battery
card for embedded IOA) read the following: When
Card type 57CB (embedded IOA with 2BCF battery working the FRUs from the serviceable event or the
card for embedded IOA) read the following: When failing item list here, the embedded storage adapter
working the FRUs from the serviceable event or the (STORIOA) has two physical parts:
failing item list here, the embedded storage adapter v The embedded storage adapter on the I/O
(STORIOA) has two physical parts: backplane.
v The embedded storage adapter on the I/O v The Battery charger and carrier card.
backplane.
v The Battery charger and carrier card. See symbolic FRU FEATCRD for the location codes of
the FRUs if they are not listed in the serviceable event
See symbolic FRU FEATCRD for the location codes of or if you are working the failing item list here.
the FRUs if they are not listed in the serviceable event
or if you are working the failing item list here. Card type 57CF (embedded IOAs on DASD backplane
with 2BC2 dual battery charger and carrier card for the
Card type 57CF (embedded IOAs on DASD backplane embedded IOAs) read the following: When working
with 2BC2 dual battery charger and carrier card for the the FRUs from the serviceable event or the failing item
embedded IOAs) read the following: When working list here, the embedded storage adapters (STORIOA)
the FRUs from the serviceable event or the failing item have two physical parts:
list here, the embedded storage adapters (STORIOA) v The embedded storage adapter on the DASD
have two physical parts: backplane.
v The embedded storage adapter on the DASD v The dual battery charger and carrier card. To
backplane. determine which battery is connected to which
v The dual battery charger and carrier card. To embedded IOA use the bus number of the IOA with
determine which battery is connected to which symbolic FRU CACHBAT.
embedded IOA use the bus number of the IOA with
symbolic FRU CACHBAT. See symbolic FRU FEATCRD for the location code of
the dual battery charger and carrier card if it is not
See symbolic FRU FEATCRD for the location code of listed in the serviceable event or if you are working the
the dual battery charger and carrier card if it is not failing item list here.
listed in the serviceable event or if you are working the Failing Item:
failing item list here.
v FI01105
2BD99500 2BD99500
v STORIOA
Explanation: Internal program error in driver code.
Problem determination: IPL the IOP to retry the Explanation: Incomplete multipath connection
device identification process. If the error persists then
Response: Incomplete multipath connection between
contact your service provider.
device backplane and device.
Failing Item:
Failing Item:
v PTFSRCH
v SIP3146
2BE034FF 2BE034FF
2BE04050 2BE04050
Explanation: Format in progress
Explanation: Enclosure does not support required
Response: No action required. This reference code is multipath function
logged for information only.
Failing Item:
v SIP3148
2BE03601 2BE03601
Explanation: System log entry only. No service action 2BE04060 2BE04060
required.
Explanation: Multipath redundancy level reduced
Response: A redundant disk unit connection has
failed.
Failing Item:
v SIP4153
2BE04150 2BE04150
v SASCABL
Explanation: I/O adapter detected PCI bus error
v SASEXP
Response: If this event appears in a serviceable event
view, work with the failing item list found there. If this
2BE04061 2BE04061
event does not appear in a serviceable event view, no
Explanation: Multipath redundancy level increased service action is required.
Response: A redundant disk unit connection has been If you are working with one of the card types below,
restored. No service action is required. the adapter has mulitple physical parts. Choose the
card type to identify the physical parts of the storage
adapter.
2BE04070 2BE04070
Card type 2BE1 (feature RAID enablement card for
Explanation: System log entry only. No service action embedded IOA) read the following: When working the
required. FRUs from the serviceable event or the failing item list
here, the embedded storage adapter (STORIOA) has
2BE04100 2BE04100 three physical parts:
v The embedded storage adapter on the I/O
Explanation: Device bus fabric error
backplane.
Response: For card type 2BE1 (feature RAID v The RAID enablement card.
enablement card for embedded IOA) read the
v The Battery charger and carrier card.
following: When working the FRUs from the
serviceable event or the failing item list here, the
embedded storage adapter (STORIOA) has three See symbolic FRU FEATCRD for the location codes of
physical parts: the FRUs if they are not listed in the serviceable event
or if you are working the failing item list here.
1. The embedded storage adapter on the I/O
backplane.
Card type 57CB (embedded IOA with 2BCF battery
2. The RAID enablement card. card for embedded IOA) read the following: When
3. The Battery charger and carrier card. working the FRUs from the serviceable event or the
failing item list here, the embedded storage adapter
See symbolic FRU FEATCRD for the location codes of (STORIOA) has two physical parts:
the FRUs if they are not listed in the serviceable event v The embedded storage adapter on the I/O
or if you are working the failing item list here. backplane.
Failing Item: v The Battery charger and carrier card.
v SIP4152
See symbolic FRU FEATCRD for the location codes of
v SASCABL the FRUs if they are not listed in the serviceable event
v SASEXP or if you are working the failing item list here.
v DEVBPLN
v STORIOA Card type 57CF (embedded IOAs on DASD backplane
with 2BC2 dual battery charger and carrier card for the
v FI01105 embedded IOAs) read the following: When working
the FRUs from the serviceable event or the failing item
2BE04101 2BE04101 list here, the embedded storage adapters (STORIOA)
have two physical parts:
Explanation: Temporary device bus fabric error
v The embedded storage adapter on the DASD
Failing Item: backplane.
v SIP4152 v The dual battery charger and carrier card. To
determine which battery is connected to which
embedded IOA use the bus number of the IOA with
2BE04110 2BE04110
symbolic FRU CACHBAT.
Explanation: Unsupported enclosure function detected
See symbolic FRU FEATCRD for the location code of
Failing Item:
the dual battery charger and carrier card if it is not
v SIP3145 listed in the serviceable event or if you are working the
failing item list here.
Failing Item:
See symbolic FRU FEATCRD for the location codes of Card type 57CB (embedded IOA with 2BCF battery
the FRUs if they are not listed in the serviceable event card) read the following: When working the FRUs from
or if you are working the failing item list here. the serviceable event or the failing item list here, the
embedded storage adapter (STORIOA) has two
Card type 57CF (embedded IOAs on DASD backplane physical parts:
with 2BC2 dual battery charger and carrier card for the v The embedded storage adapter on the I/O
embedded IOAs) read the following: When working backplane.
the FRUs from the serviceable event or the failing item
list here, the embedded storage adapters (STORIOA) v The Battery charger and carrier card.
have two physical parts:
See symbolic FRU FEATCRD for the location codes of
v The embedded storage adapter on the DASD
the FRUs if they are not listed in the serviceable event
backplane.
or if you are working the failing item list here.
v The dual battery charger and carrier card. To
determine which battery is connected to which Card type 57CF (embedded IOAs on DASD backplane
embedded IOA use the bus number of the IOA with with 2BC2 dual battery charger and carrier card) read
symbolic FRU CACHBAT. the following: When working the FRUs from the
serviceable event or the failing item list here, the
embedded storage adapters (STORIOA) have two
physical parts:
v The embedded storage adapter on the DASD Card type 57CF (embedded IOAs on DASD backplane
backplane. with 2BC2 dual battery charger and carrier card for the
v The dual battery charger and carrier card. To embedded IOAs) read the following: When working
determine which battery is connected to which the FRUs from the serviceable event or the failing item
embedded IOA use the bus number of the IOA with list here, the embedded storage adapters (STORIOA)
symbolic FRU CACHBAT. have two physical parts:
v The embedded storage adapter on the DASD
See symbolic FRU FEATCRD for the location code of backplane.
the dual battery charger and carrier card if it is not v The dual battery charger and carrier card. To
listed in the serviceable event or if you are working the determine which battery is connected to which
failing item list here. embedded IOA use the bus number of the IOA with
Failing Item: symbolic FRU CACHBAT.
v CACHBAT
See symbolic FRU FEATCRD for the location code of
v STORIOA the dual battery charger and carrier card if it is not
v FEATCRD listed in the serviceable event or if you are working the
failing item list here.
Card type 57CB (embedded IOA with 2BCF battery 2BE08141 2BE08141
card for embedded IOA) read the following: When
working the FRUs from the serviceable event or the Explanation: IOA detected recoverable device error
failing item list here, the embedded storage adapter
Response: No action is required. This reference code
(STORIOA) has two physical parts:
is logged for information only.
v The embedded storage adapter on the I/O
backplane.
2BE08146 2BE08146
v The Battery charger and carrier card.
Explanation: Disk device detected recoverable error
See symbolic FRU FEATCRD for the location codes of
Failing Item:
the FRUs if they are not listed in the serviceable event
or if you are working the failing item list here. v FI01105
See symbolic FRU FEATCRD for the location code of See symbolic FRU FEATCRD for the location code of
the dual battery charger and carrier card if it is not the dual battery charger and carrier card if it is not
listed in the serviceable event or if you are working the listed in the serviceable event or if you are working the
failing item list here. failing item list here.
Failing Item: Failing Item:
v PTFSRCH v PTFSRCH
v STORIOA v STORIOA
See symbolic FRU FEATCRD for the location codes of See symbolic FRU FEATCRD for the location codes of
the FRUs if they are not listed in the serviceable event the FRUs if they are not listed in the serviceable event
or if you are working the failing item list here. or if you are working the failing item list here.
Card type 57CB (embedded IOA with 2BCF battery Card type 57CB (embedded IOA with 2BCF battery
card for embedded IOA) read the following: When card for embedded IOA) read the following: When
working the FRUs from the serviceable event or the working the FRUs from the serviceable event or the
failing item list here, the embedded storage adapter failing item list here, the embedded storage adapter
(STORIOA) has two physical parts: (STORIOA) has two physical parts:
v The embedded storage adapter on the I/O v The embedded storage adapter on the I/O
backplane. backplane.
v The Battery charger and carrier card. v The Battery charger and carrier card.
See symbolic FRU FEATCRD for the location codes of See symbolic FRU FEATCRD for the location codes of
the FRUs if they are not listed in the serviceable event the FRUs if they are not listed in the serviceable event
or if you are working the failing item list here. or if you are working the failing item list here.
Card type 57CF (embedded IOAs on DASD backplane Card type 57CF (embedded IOAs on DASD backplane
with 2BC2 dual battery charger and carrier card for the with 2BC2 dual battery charger and carrier card for the
embedded IOAs) read the following: When working embedded IOAs) read the following: When working
the FRUs from the serviceable event or the failing item the FRUs from the serviceable event or the failing item
list here, the embedded storage adapters (STORIOA) list here, the embedded storage adapters (STORIOA)
have two physical parts: have two physical parts:
v The embedded storage adapter on the DASD v The embedded storage adapter on the DASD
backplane. backplane.
v The dual battery charger and carrier card. To v The dual battery charger and carrier card. To
determine which battery is connected to which determine which battery is connected to which
embedded IOA use the bus number of the IOA with embedded IOA use the bus number of the IOA with
symbolic FRU CACHBAT. symbolic FRU CACHBAT.
See symbolic FRU FEATCRD for the location code of the FRUs from the serviceable event or the failing item
the dual battery charger and carrier card if it is not list here, the embedded storage adapters (STORIOA)
listed in the serviceable event or if you are working the have two physical parts:
failing item list here. v The embedded storage adapter on the DASD
Failing Item: backplane.
v PTFSRCH v The dual battery charger and carrier card. To
determine which battery is connected to which
v STORIOA
embedded IOA use the bus number of the IOA with
symbolic FRU CACHBAT.
2BE08157 2BE08157
See symbolic FRU FEATCRD for the location code of
Explanation: I/O adapter card error
the dual battery charger and carrier card if it is not
Response: The FRU list in the Service Action Log will listed in the serviceable event or if you are working the
vary based on the conditions this event was logged for. failing item list here.
Display the Service Action Log entry for this SRC. If Failing Item:
the Failing Item indicates an I/O adapter, then replace v SVCDOCS
the I/O adapter. If the Failing Item indicates
v STORIOA
SVCDOCS, then do NOT replace the I/O adapter. This
is a recoverable error. Use Hardware Service Manager
to re-IPL the virtual I/O processor that is associated 2BE08300 2BE08300
with this I/O adapter. Other resources attached to the
Explanation: IOA hardware error or PCI bus error
virtual I/O processor may then need to be Varied On.
Response: If you are working with one of the card
If you are replacing the I/O adapter and you are
types below, the adapter has mulitple physical parts.
working with one of the card types below, the adapter
Choose the card type to identify the physical parts of
has mulitple physical parts. Choose the card type to
the storage adapter.
identify the physical parts of the storage adapter.
Card type 2BE1 (feature RAID enablement card for
Card type 2BE1 (feature RAID enablement card for
embedded IOA) read the following: When working the
embedded IOA) read the following: When working the
FRUs from the serviceable event or the failing item list
FRUs from the serviceable event or the failing item list
here, the embedded storage adapter (STORIOA) has
here, the embedded storage adapter (STORIOA) has
three physical parts:
three physical parts:
v The embedded storage adapter on the I/O
v The embedded storage adapter on the I/O
backplane.
backplane.
v The RAID enablement card.
v The RAID enablement card.
v The Battery charger and carrier card.
v The Battery charger and carrier card.
the FRUs from the serviceable event or the failing item embedded IOAs) read the following: When working
list here, the embedded storage adapters (STORIOA) the FRUs from the serviceable event or the failing item
have two physical parts: list here, the embedded storage adapters (STORIOA)
v The embedded storage adapter on the DASD have two physical parts:
backplane. v The embedded storage adapter on the DASD
v The dual battery charger and carrier card. To backplane.
determine which battery is connected to which v The dual battery charger and carrier card. To
embedded IOA use the bus number of the IOA with determine which battery is connected to which
symbolic FRU CACHBAT. embedded IOA use the bus number of the IOA with
symbolic FRU CACHBAT.
See symbolic FRU FEATCRD for the location code of
the dual battery charger and carrier card if it is not See symbolic FRU FEATCRD for the location code of
listed in the serviceable event or if you are working the the dual battery charger and carrier card if it is not
failing item list here. listed in the serviceable event or if you are working the
failing item list here.
Failing Item:
v STORIOA Failing Item:
v ANYBRDG v PTFSRCH
v PTFSRCH v STORIOA
Explanation: Not valid condition in Licensed Internal Explanation: Missing Licensed Internal Code
Code Response: Ensure that the code necessary to support
Response: If you are working with one of the card this I/O adapter is loaded.
types below, the adapter has mulitple physical parts. If you are working with one of the card types below,
Choose the card type to identify the physical parts of the adapter has mulitple physical parts. Choose the
the storage adapter. card type to identify the physical parts of the storage
Card type 2BE1 (feature RAID enablement card for adapter.
embedded IOA) read the following: When working the Card type 2BE1 (feature RAID enablement card for
FRUs from the serviceable event or the failing item list embedded IOA) read the following: When working the
here, the embedded storage adapter (STORIOA) has FRUs from the serviceable event or the failing item list
three physical parts: here, the embedded storage adapter (STORIOA) has
v The embedded storage adapter on the I/O three physical parts:
backplane. v The embedded storage adapter on the I/O
v The RAID enablement card. backplane.
v The Battery charger and carrier card. v The RAID enablement card.
v The Battery charger and carrier card.
See symbolic FRU FEATCRD for the location codes of
the FRUs if they are not listed in the serviceable event See symbolic FRU FEATCRD for the location codes of
or if you are working the failing item list here. the FRUs if they are not listed in the serviceable event
or if you are working the failing item list here.
Card type 57CB (embedded IOA with 2BCF battery
card for embedded IOA) read the following: When Card type 57CB (embedded IOA with 2BCF battery
working the FRUs from the serviceable event or the card for embedded IOA) read the following: When
failing item list here, the embedded storage adapter working the FRUs from the serviceable event or the
(STORIOA) has two physical parts: failing item list here, the embedded storage adapter
v The embedded storage adapter on the I/O (STORIOA) has two physical parts:
backplane. v The embedded storage adapter on the I/O
v The Battery charger and carrier card. backplane.
v The Battery charger and carrier card.
See symbolic FRU FEATCRD for the location codes of
the FRUs if they are not listed in the serviceable event See symbolic FRU FEATCRD for the location codes of
or if you are working the failing item list here. the FRUs if they are not listed in the serviceable event
or if you are working the failing item list here.
Card type 57CF (embedded IOAs on DASD backplane
with 2BC2 dual battery charger and carrier card for the
Card type 57CF (embedded IOAs on DASD backplane failing item list here, the embedded storage adapter
with 2BC2 dual battery charger and carrier card for the (STORIOA) has two physical parts:
embedded IOAs) read the following: When working v The embedded storage adapter on the I/O
the FRUs from the serviceable event or the failing item backplane.
list here, the embedded storage adapters (STORIOA)
v The Battery charger and carrier card.
have two physical parts:
v The embedded storage adapter on the DASD See symbolic FRU FEATCRD for the location codes of
backplane. the FRUs if they are not listed in the serviceable event
v The dual battery charger and carrier card. To or if you are working the failing item list here.
determine which battery is connected to which
embedded IOA use the bus number of the IOA with Card type 57CF (embedded IOAs on DASD backplane
symbolic FRU CACHBAT. with 2BC2 dual battery charger and carrier card for the
embedded IOAs) read the following: When working
See symbolic FRU FEATCRD for the location code of the FRUs from the serviceable event or the failing item
the dual battery charger and carrier card if it is not list here, the embedded storage adapters (STORIOA)
listed in the serviceable event or if you are working the have two physical parts:
failing item list here. v The embedded storage adapter on the DASD
Failing Item: backplane.
v SVCDOCS v The dual battery charger and carrier card. To
determine which battery is connected to which
v STORIOA
embedded IOA use the bus number of the IOA with
symbolic FRU CACHBAT.
2BE08400 2BE08400
See symbolic FRU FEATCRD for the location code of
Explanation: Licensed Internal Code error
the dual battery charger and carrier card if it is not
Failing Item: listed in the serviceable event or if you are working the
v PTFSRCH failing item list here.
Failing Item:
2BE08404 2BE08404 v FI01105
Explanation: System log entry only. No service action v STORIOA
required.
2BE09001 2BE09001
2BE09000 2BE09000 Explanation: Device configuration error
Explanation: Device error Failing Item:
Response: If you are working with one of the card v NEXTLVL
types below, the adapter has mulitple physical parts.
Choose the card type to identify the physical parts of
2BE09002 2BE09002
the storage adapter.
Explanation: Device error
Card type 2BE1 (feature RAID enablement card for
embedded IOA) read the following: When working the Failing Item:
FRUs from the serviceable event or the failing item list v NEXTLVL
here, the embedded storage adapter (STORIOA) has
three physical parts:
v The embedded storage adapter on the I/O 2BE09008 2BE09008
backplane. Explanation: I/O card does not support functions
v The RAID enablement card. expected by devices
v The Battery charger and carrier card. Failing Item:
v SIP3130
See symbolic FRU FEATCRD for the location codes of
the FRUs if they are not listed in the serviceable event
or if you are working the failing item list here. 2BE09010 2BE09010
Explanation: Cache data associated with attached
Card type 57CB (embedded IOA with 2BCF battery devices cannot be found
card for embedded IOA) read the following: When
working the FRUs from the serviceable event or the Failing Item:
v SIP3120
2BE09026 2BE09026
Explanation: Disk unit not found at required physical
2BE09011 2BE09011
location
Explanation: Cache data belongs to devices other than
Response: A previously exposed disk unit in an array
those attached
was not found at the required physical location.
Failing Item:
Failing Item:
v NEXTLVL
v NEXTLVL
2BE09020 2BE09020
2BE09027 2BE09027
Explanation: Two or more disk units missing from
Explanation: Array not functional due to parity out of
RAID-5 or RAID-6 array
synchronization
Failing Item:
Response: Array is or would become exposed and
v SIP3111 parity data is out of synchronization
Failing Item:
2BE09021 2BE09021
v SIP3113
Explanation: Two or more disk units missing from
RAID-5 or RAID-6 array
2BE09028 2BE09028
Failing Item:
Explanation: Maximum number of functional arrays
v SIP3111 has been exceeded
Response: Reduce the number of arrays on this I/O
2BE09022 2BE09022 adapter. Either move all the devices in an array to
Explanation: Two or more disk units missing from another I/O adapter that supports arrays, or stop an
RAID-5 or RAID-6 array array on this I/O adapter.
v SIP3111 v SVCDOCS
Explanation: One or more array members not in Explanation: Maximum number of functional array
required physical locations members has been exceeded
Failing Item:
2BE09032 2BE09032
v NEXTLVL
Explanation: A disk unit in an array is missing or
failed
2BE09054 2BE09054
Response: The array is still protected, but the disk
unit should be replaced. Explanation: IOA resources not available due to
previous problems
Failing Item:
Failing Item:
v SIP3110
v SIP3121
v FI02112
2BE09070 2BE09070
2BE09040 2BE09040
Explanation: System log entry only. No service action
Explanation: Re-synchronization of array parity was
required.
initiated
Response: No action required.
2BE09071 2BE09071
Explanation: Link from IOA to auxiliary or remote
2BE09041 2BE09041
IOA is operational
Explanation: Background array parity check detected
Response: No service action required.
and corrected errors
Response: Call your next level of support to report
2BE09072 2BE09072
the problem.
Explanation: Link from IOA to auxiliary or remote
Failing Item:
IOA is non-operational
v NEXTLVL
Response: No service action required.
2BE09042 2BE09042
2BE09073 2BE09073
Explanation: Background parity check corrected errors
on disk unit Explanation: Multiple I/O adapters connected in a not
valid configuration
Response: Call your next level of support to report
the problem. Failing Item:
v SIP4140
Failing Item:
v NEXTLVL
2BE09074 2BE09074
2BE09051 2BE09051
2BE09075 2BE09075
Explanation: Cache data exists for one or more
missing or failed devices Explanation: Incomplete multipath connection
between IOA and remote IOA
Failing Item:
Failing Item:
v SIP3132
v SIP4149
2BE09052 2BE09052
Explanation: Cache data exists for one or more
modified devices
Response: Contact your next level of support.
Failing Item:
2BE09076 2BE09076
v FI01105
Explanation: Missing auxiliary IOA or remote IOA
v STORIOA
Failing Item:
v SIP4147 2BE09082 2BE09082
Explanation: Device error
2BE09081 2BE09081
Response: If you are working with one of the card
Explanation: Device error types below, the adapter has mulitple physical parts.
Response: If you are working with one of the card Choose the card type to identify the physical parts of
types below, the adapter has mulitple physical parts. the storage adapter.
Choose the card type to identify the physical parts of Card type 2BE1 (feature RAID enablement card for
the storage adapter. embedded IOA) read the following: When working the
Card type 2BE1 (feature RAID enablement card for FRUs from the serviceable event or the failing item list
embedded IOA) read the following: When working the here, the embedded storage adapter (STORIOA) has
FRUs from the serviceable event or the failing item list three physical parts:
here, the embedded storage adapter (STORIOA) has v The embedded storage adapter on the I/O
three physical parts: backplane.
v The embedded storage adapter on the I/O v The RAID enablement card.
backplane. v The Battery charger and carrier card.
v The RAID enablement card.
v The Battery charger and carrier card. See symbolic FRU FEATCRD for the location codes of
the FRUs if they are not listed in the serviceable event
See symbolic FRU FEATCRD for the location codes of or if you are working the failing item list here.
the FRUs if they are not listed in the serviceable event
or if you are working the failing item list here. Card type 57CB (embedded IOA with 2BCF battery
card for embedded IOA) read the following: When
Card type 57CB (embedded IOA with 2BCF battery working the FRUs from the serviceable event or the
card for embedded IOA) read the following: When failing item list here, the embedded storage adapter
working the FRUs from the serviceable event or the (STORIOA) has two physical parts:
failing item list here, the embedded storage adapter v The embedded storage adapter on the I/O
(STORIOA) has two physical parts: backplane.
v The embedded storage adapter on the I/O v The Battery charger and carrier card.
backplane.
v The Battery charger and carrier card. See symbolic FRU FEATCRD for the location codes of
the FRUs if they are not listed in the serviceable event
See symbolic FRU FEATCRD for the location codes of or if you are working the failing item list here.
the FRUs if they are not listed in the serviceable event
or if you are working the failing item list here. Card type 57CF (embedded IOAs on DASD backplane
with 2BC2 dual battery charger and carrier card for the
Card type 57CF (embedded IOAs on DASD backplane embedded IOAs) read the following: When working
with 2BC2 dual battery charger and carrier card for the the FRUs from the serviceable event or the failing item
embedded IOAs) read the following: When working list here, the embedded storage adapters (STORIOA)
the FRUs from the serviceable event or the failing item have two physical parts:
list here, the embedded storage adapters (STORIOA) v The embedded storage adapter on the DASD
have two physical parts: backplane.
v The embedded storage adapter on the DASD v The dual battery charger and carrier card. To
backplane. determine which battery is connected to which
v The dual battery charger and carrier card. To embedded IOA use the bus number of the IOA with
determine which battery is connected to which symbolic FRU CACHBAT.
embedded IOA use the bus number of the IOA with
symbolic FRU CACHBAT. See symbolic FRU FEATCRD for the location code of
the dual battery charger and carrier card if it is not
See symbolic FRU FEATCRD for the location code of listed in the serviceable event or if you are working the
the dual battery charger and carrier card if it is not failing item list here.
listed in the serviceable event or if you are working the Failing Item:
failing item list here.
v FI01105
2BE09500 2BE09500
v STORIOA
Explanation: Internal program error in driver code.
Problem determination: IPL the IOP to retry the Explanation: Incomplete multipath connection
device identification process. If the error persists then
Response: Incomplete multipath connection between
contact your service provider.
device backplane and device.
Failing Item:
Failing Item:
v PTFSRCH
v SIP3146
2BE134FF 2BE134FF
2BE14050 2BE14050
Explanation: Format in progress
Explanation: Enclosure does not support required
Response: No action required. This reference code is multipath function
logged for information only.
Failing Item:
v SIP3148
2BE13601 2BE13601
Explanation: System log entry only. No service action 2BE14060 2BE14060
required.
Explanation: Multipath redundancy level reduced
Response: A redundant disk unit connection has
failed.
Failing Item:
v SIP4153
2BE14150 2BE14150
v SASCABL
Explanation: I/O adapter detected PCI bus error
v SASEXP
Response: If this event appears in a serviceable event
view, work with the failing item list found there. If this
2BE14061 2BE14061
event does not appear in a serviceable event view, no
Explanation: Multipath redundancy level increased service action is required.
Response: A redundant disk unit connection has been If you are working with one of the card types below,
restored. No service action is required. the adapter has mulitple physical parts. Choose the
card type to identify the physical parts of the storage
adapter.
2BE14070 2BE14070
Card type 2BE1 (feature RAID enablement card for
Explanation: System log entry only. No service action embedded IOA) read the following: When working the
required. FRUs from the serviceable event or the failing item list
here, the embedded storage adapter (STORIOA) has
2BE14100 2BE14100 three physical parts:
v The embedded storage adapter on the I/O
Explanation: Device bus fabric error
backplane.
Response: For card type 2BE1 (feature RAID v The RAID enablement card.
enablement card for embedded IOA) read the
v The Battery charger and carrier card.
following: When working the FRUs from the
serviceable event or the failing item list here, the
embedded storage adapter (STORIOA) has three See symbolic FRU FEATCRD for the location codes of
physical parts: the FRUs if they are not listed in the serviceable event
or if you are working the failing item list here.
1. The embedded storage adapter on the I/O
backplane.
Card type 57CB (embedded IOA with 2BCF battery
2. The RAID enablement card. card for embedded IOA) read the following: When
3. The Battery charger and carrier card. working the FRUs from the serviceable event or the
failing item list here, the embedded storage adapter
See symbolic FRU FEATCRD for the location codes of (STORIOA) has two physical parts:
the FRUs if they are not listed in the serviceable event v The embedded storage adapter on the I/O
or if you are working the failing item list here. backplane.
Failing Item: v The Battery charger and carrier card.
v SIP4152
See symbolic FRU FEATCRD for the location codes of
v SASCABL the FRUs if they are not listed in the serviceable event
v SASEXP or if you are working the failing item list here.
v DEVBPLN
v STORIOA Card type 57CF (embedded IOAs on DASD backplane
with 2BC2 dual battery charger and carrier card for the
v FI01105 embedded IOAs) read the following: When working
the FRUs from the serviceable event or the failing item
2BE14101 2BE14101 list here, the embedded storage adapters (STORIOA)
have two physical parts:
Explanation: Temporary device bus fabric error
v The embedded storage adapter on the DASD
Failing Item: backplane.
v SIP4152 v The dual battery charger and carrier card. To
determine which battery is connected to which
embedded IOA use the bus number of the IOA with
2BE14110 2BE14110
symbolic FRU CACHBAT.
Explanation: Unsupported enclosure function detected
See symbolic FRU FEATCRD for the location code of
Failing Item:
the dual battery charger and carrier card if it is not
v SIP3145 listed in the serviceable event or if you are working the
failing item list here.
Failing Item:
See symbolic FRU FEATCRD for the location codes of Card type 57CB (embedded IOA with 2BCF battery
the FRUs if they are not listed in the serviceable event card) read the following: When working the FRUs from
or if you are working the failing item list here. the serviceable event or the failing item list here, the
embedded storage adapter (STORIOA) has two
Card type 57CF (embedded IOAs on DASD backplane physical parts:
with 2BC2 dual battery charger and carrier card for the v The embedded storage adapter on the I/O
embedded IOAs) read the following: When working backplane.
the FRUs from the serviceable event or the failing item
list here, the embedded storage adapters (STORIOA) v The Battery charger and carrier card.
have two physical parts:
See symbolic FRU FEATCRD for the location codes of
v The embedded storage adapter on the DASD
the FRUs if they are not listed in the serviceable event
backplane.
or if you are working the failing item list here.
v The dual battery charger and carrier card. To
determine which battery is connected to which Card type 57CF (embedded IOAs on DASD backplane
embedded IOA use the bus number of the IOA with with 2BC2 dual battery charger and carrier card) read
symbolic FRU CACHBAT. the following: When working the FRUs from the
serviceable event or the failing item list here, the
embedded storage adapters (STORIOA) have two
physical parts:
v The embedded storage adapter on the DASD Card type 57CF (embedded IOAs on DASD backplane
backplane. with 2BC2 dual battery charger and carrier card for the
v The dual battery charger and carrier card. To embedded IOAs) read the following: When working
determine which battery is connected to which the FRUs from the serviceable event or the failing item
embedded IOA use the bus number of the IOA with list here, the embedded storage adapters (STORIOA)
symbolic FRU CACHBAT. have two physical parts:
v The embedded storage adapter on the DASD
See symbolic FRU FEATCRD for the location code of backplane.
the dual battery charger and carrier card if it is not v The dual battery charger and carrier card. To
listed in the serviceable event or if you are working the determine which battery is connected to which
failing item list here. embedded IOA use the bus number of the IOA with
Failing Item: symbolic FRU CACHBAT.
v CACHBAT
See symbolic FRU FEATCRD for the location code of
v STORIOA the dual battery charger and carrier card if it is not
v FEATCRD listed in the serviceable event or if you are working the
failing item list here.
Card type 57CB (embedded IOA with 2BCF battery 2BE18141 2BE18141
card for embedded IOA) read the following: When
working the FRUs from the serviceable event or the Explanation: IOA detected recoverable device error
failing item list here, the embedded storage adapter
Response: No action is required. This reference code
(STORIOA) has two physical parts:
is logged for information only.
v The embedded storage adapter on the I/O
backplane.
2BE18146 2BE18146
v The Battery charger and carrier card.
Explanation: Disk device detected recoverable error
See symbolic FRU FEATCRD for the location codes of
Failing Item:
the FRUs if they are not listed in the serviceable event
or if you are working the failing item list here. v FI01105
See symbolic FRU FEATCRD for the location code of See symbolic FRU FEATCRD for the location code of
the dual battery charger and carrier card if it is not the dual battery charger and carrier card if it is not
listed in the serviceable event or if you are working the listed in the serviceable event or if you are working the
failing item list here. failing item list here.
Failing Item: Failing Item:
v PTFSRCH v PTFSRCH
v STORIOA v STORIOA
See symbolic FRU FEATCRD for the location codes of See symbolic FRU FEATCRD for the location codes of
the FRUs if they are not listed in the serviceable event the FRUs if they are not listed in the serviceable event
or if you are working the failing item list here. or if you are working the failing item list here.
Card type 57CB (embedded IOA with 2BCF battery Card type 57CB (embedded IOA with 2BCF battery
card for embedded IOA) read the following: When card for embedded IOA) read the following: When
working the FRUs from the serviceable event or the working the FRUs from the serviceable event or the
failing item list here, the embedded storage adapter failing item list here, the embedded storage adapter
(STORIOA) has two physical parts: (STORIOA) has two physical parts:
v The embedded storage adapter on the I/O v The embedded storage adapter on the I/O
backplane. backplane.
v The Battery charger and carrier card. v The Battery charger and carrier card.
See symbolic FRU FEATCRD for the location codes of See symbolic FRU FEATCRD for the location codes of
the FRUs if they are not listed in the serviceable event the FRUs if they are not listed in the serviceable event
or if you are working the failing item list here. or if you are working the failing item list here.
Card type 57CF (embedded IOAs on DASD backplane Card type 57CF (embedded IOAs on DASD backplane
with 2BC2 dual battery charger and carrier card for the with 2BC2 dual battery charger and carrier card for the
embedded IOAs) read the following: When working embedded IOAs) read the following: When working
the FRUs from the serviceable event or the failing item the FRUs from the serviceable event or the failing item
list here, the embedded storage adapters (STORIOA) list here, the embedded storage adapters (STORIOA)
have two physical parts: have two physical parts:
v The embedded storage adapter on the DASD v The embedded storage adapter on the DASD
backplane. backplane.
v The dual battery charger and carrier card. To v The dual battery charger and carrier card. To
determine which battery is connected to which determine which battery is connected to which
embedded IOA use the bus number of the IOA with embedded IOA use the bus number of the IOA with
symbolic FRU CACHBAT. symbolic FRU CACHBAT.
See symbolic FRU FEATCRD for the location code of the FRUs from the serviceable event or the failing item
the dual battery charger and carrier card if it is not list here, the embedded storage adapters (STORIOA)
listed in the serviceable event or if you are working the have two physical parts:
failing item list here. v The embedded storage adapter on the DASD
Failing Item: backplane.
v PTFSRCH v The dual battery charger and carrier card. To
determine which battery is connected to which
v STORIOA
embedded IOA use the bus number of the IOA with
symbolic FRU CACHBAT.
2BE18157 2BE18157
See symbolic FRU FEATCRD for the location code of
Explanation: I/O adapter card error
the dual battery charger and carrier card if it is not
Response: The FRU list in the Service Action Log will listed in the serviceable event or if you are working the
vary based on the conditions this event was logged for. failing item list here.
Display the Service Action Log entry for this SRC. If Failing Item:
the Failing Item indicates an I/O adapter, then replace v SVCDOCS
the I/O adapter. If the Failing Item indicates
v STORIOA
SVCDOCS, then do NOT replace the I/O adapter. This
is a recoverable error. Use Hardware Service Manager
to re-IPL the virtual I/O processor that is associated 2BE18300 2BE18300
with this I/O adapter. Other resources attached to the
Explanation: IOA hardware error or PCI bus error
virtual I/O processor may then need to be Varied On.
Response: If you are working with one of the card
If you are replacing the I/O adapter and you are
types below, the adapter has mulitple physical parts.
working with one of the card types below, the adapter
Choose the card type to identify the physical parts of
has mulitple physical parts. Choose the card type to
the storage adapter.
identify the physical parts of the storage adapter.
Card type 2BE1 (feature RAID enablement card for
Card type 2BE1 (feature RAID enablement card for
embedded IOA) read the following: When working the
embedded IOA) read the following: When working the
FRUs from the serviceable event or the failing item list
FRUs from the serviceable event or the failing item list
here, the embedded storage adapter (STORIOA) has
here, the embedded storage adapter (STORIOA) has
three physical parts:
three physical parts:
v The embedded storage adapter on the I/O
v The embedded storage adapter on the I/O
backplane.
backplane.
v The RAID enablement card.
v The RAID enablement card.
v The Battery charger and carrier card.
v The Battery charger and carrier card.
the FRUs from the serviceable event or the failing item embedded IOAs) read the following: When working
list here, the embedded storage adapters (STORIOA) the FRUs from the serviceable event or the failing item
have two physical parts: list here, the embedded storage adapters (STORIOA)
v The embedded storage adapter on the DASD have two physical parts:
backplane. v The embedded storage adapter on the DASD
v The dual battery charger and carrier card. To backplane.
determine which battery is connected to which v The dual battery charger and carrier card. To
embedded IOA use the bus number of the IOA with determine which battery is connected to which
symbolic FRU CACHBAT. embedded IOA use the bus number of the IOA with
symbolic FRU CACHBAT.
See symbolic FRU FEATCRD for the location code of
the dual battery charger and carrier card if it is not See symbolic FRU FEATCRD for the location code of
listed in the serviceable event or if you are working the the dual battery charger and carrier card if it is not
failing item list here. listed in the serviceable event or if you are working the
failing item list here.
Failing Item:
v STORIOA Failing Item:
v ANYBRDG v PTFSRCH
v PTFSRCH v STORIOA
Explanation: Not valid condition in Licensed Internal Explanation: Missing Licensed Internal Code
Code Response: Ensure that the code necessary to support
Response: If you are working with one of the card this I/O adapter is loaded.
types below, the adapter has mulitple physical parts. If you are working with one of the card types below,
Choose the card type to identify the physical parts of the adapter has mulitple physical parts. Choose the
the storage adapter. card type to identify the physical parts of the storage
Card type 2BE1 (feature RAID enablement card for adapter.
embedded IOA) read the following: When working the Card type 2BE1 (feature RAID enablement card for
FRUs from the serviceable event or the failing item list embedded IOA) read the following: When working the
here, the embedded storage adapter (STORIOA) has FRUs from the serviceable event or the failing item list
three physical parts: here, the embedded storage adapter (STORIOA) has
v The embedded storage adapter on the I/O three physical parts:
backplane. v The embedded storage adapter on the I/O
v The RAID enablement card. backplane.
v The Battery charger and carrier card. v The RAID enablement card.
v The Battery charger and carrier card.
See symbolic FRU FEATCRD for the location codes of
the FRUs if they are not listed in the serviceable event See symbolic FRU FEATCRD for the location codes of
or if you are working the failing item list here. the FRUs if they are not listed in the serviceable event
or if you are working the failing item list here.
Card type 57CB (embedded IOA with 2BCF battery
card for embedded IOA) read the following: When Card type 57CB (embedded IOA with 2BCF battery
working the FRUs from the serviceable event or the card for embedded IOA) read the following: When
failing item list here, the embedded storage adapter working the FRUs from the serviceable event or the
(STORIOA) has two physical parts: failing item list here, the embedded storage adapter
v The embedded storage adapter on the I/O (STORIOA) has two physical parts:
backplane. v The embedded storage adapter on the I/O
v The Battery charger and carrier card. backplane.
v The Battery charger and carrier card.
See symbolic FRU FEATCRD for the location codes of
the FRUs if they are not listed in the serviceable event See symbolic FRU FEATCRD for the location codes of
or if you are working the failing item list here. the FRUs if they are not listed in the serviceable event
or if you are working the failing item list here.
Card type 57CF (embedded IOAs on DASD backplane
with 2BC2 dual battery charger and carrier card for the
Card type 57CF (embedded IOAs on DASD backplane failing item list here, the embedded storage adapter
with 2BC2 dual battery charger and carrier card for the (STORIOA) has two physical parts:
embedded IOAs) read the following: When working v The embedded storage adapter on the I/O
the FRUs from the serviceable event or the failing item backplane.
list here, the embedded storage adapters (STORIOA)
v The Battery charger and carrier card.
have two physical parts:
v The embedded storage adapter on the DASD See symbolic FRU FEATCRD for the location codes of
backplane. the FRUs if they are not listed in the serviceable event
v The dual battery charger and carrier card. To or if you are working the failing item list here.
determine which battery is connected to which
embedded IOA use the bus number of the IOA with Card type 57CF (embedded IOAs on DASD backplane
symbolic FRU CACHBAT. with 2BC2 dual battery charger and carrier card for the
embedded IOAs) read the following: When working
See symbolic FRU FEATCRD for the location code of the FRUs from the serviceable event or the failing item
the dual battery charger and carrier card if it is not list here, the embedded storage adapters (STORIOA)
listed in the serviceable event or if you are working the have two physical parts:
failing item list here. v The embedded storage adapter on the DASD
Failing Item: backplane.
v SVCDOCS v The dual battery charger and carrier card. To
determine which battery is connected to which
v STORIOA
embedded IOA use the bus number of the IOA with
symbolic FRU CACHBAT.
2BE18400 2BE18400
See symbolic FRU FEATCRD for the location code of
Explanation: Licensed Internal Code error
the dual battery charger and carrier card if it is not
Failing Item: listed in the serviceable event or if you are working the
v PTFSRCH failing item list here.
Failing Item:
2BE18404 2BE18404 v FI01105
Explanation: System log entry only. No service action v STORIOA
required.
2BE19001 2BE19001
2BE19000 2BE19000 Explanation: Device configuration error
Explanation: Device error Failing Item:
Response: If you are working with one of the card v NEXTLVL
types below, the adapter has mulitple physical parts.
Choose the card type to identify the physical parts of
2BE19002 2BE19002
the storage adapter.
Explanation: Device error
Card type 2BE1 (feature RAID enablement card for
embedded IOA) read the following: When working the Failing Item:
FRUs from the serviceable event or the failing item list v NEXTLVL
here, the embedded storage adapter (STORIOA) has
three physical parts:
v The embedded storage adapter on the I/O 2BE19008 2BE19008
backplane. Explanation: I/O card does not support functions
v The RAID enablement card. expected by devices
v The Battery charger and carrier card. Failing Item:
v SIP3130
See symbolic FRU FEATCRD for the location codes of
the FRUs if they are not listed in the serviceable event
or if you are working the failing item list here. 2BE19010 2BE19010
Explanation: Cache data associated with attached
Card type 57CB (embedded IOA with 2BCF battery devices cannot be found
card for embedded IOA) read the following: When
working the FRUs from the serviceable event or the Failing Item:
v SIP3120
2BE19026 2BE19026
Explanation: Disk unit not found at required physical
2BE19011 2BE19011
location
Explanation: Cache data belongs to devices other than
Response: A previously exposed disk unit in an array
those attached
was not found at the required physical location.
Failing Item:
Failing Item:
v NEXTLVL
v NEXTLVL
2BE19020 2BE19020
2BE19027 2BE19027
Explanation: Two or more disk units missing from
Explanation: Array not functional due to parity out of
RAID-5 or RAID-6 array
synchronization
Failing Item:
Response: Array is or would become exposed and
v SIP3111 parity data is out of synchronization
Failing Item:
2BE19021 2BE19021
v SIP3113
Explanation: Two or more disk units missing from
RAID-5 or RAID-6 array
2BE19028 2BE19028
Failing Item:
Explanation: Maximum number of functional arrays
v SIP3111 has been exceeded
Response: Reduce the number of arrays on this I/O
2BE19022 2BE19022 adapter. Either move all the devices in an array to
Explanation: Two or more disk units missing from another I/O adapter that supports arrays, or stop an
RAID-5 or RAID-6 array array on this I/O adapter.
v SIP3111 v SVCDOCS
Explanation: One or more array members not in Explanation: Maximum number of functional array
required physical locations members has been exceeded
Failing Item:
2BE19032 2BE19032
v NEXTLVL
Explanation: A disk unit in an array is missing or
failed
2BE19054 2BE19054
Response: The array is still protected, but the disk
unit should be replaced. Explanation: IOA resources not available due to
previous problems
Failing Item:
Failing Item:
v SIP3110
v SIP3121
v FI02112
2BE19070 2BE19070
2BE19040 2BE19040
Explanation: System log entry only. No service action
Explanation: Re-synchronization of array parity was
required.
initiated
Response: No action required.
2BE19071 2BE19071
Explanation: Link from IOA to auxiliary or remote
2BE19041 2BE19041
IOA is operational
Explanation: Background array parity check detected
Response: No service action required.
and corrected errors
Response: Call your next level of support to report
2BE19072 2BE19072
the problem.
Explanation: Link from IOA to auxiliary or remote
Failing Item:
IOA is non-operational
v NEXTLVL
Response: No service action required.
2BE19042 2BE19042
2BE19073 2BE19073
Explanation: Background parity check corrected errors
on disk unit Explanation: Multiple I/O adapters connected in a not
valid configuration
Response: Call your next level of support to report
the problem. Failing Item:
v SIP4140
Failing Item:
v NEXTLVL
2BE19074 2BE19074
2BE19051 2BE19051
2BE19075 2BE19075
Explanation: Cache data exists for one or more
missing or failed devices Explanation: Incomplete multipath connection
between IOA and remote IOA
Failing Item:
Failing Item:
v SIP3132
v SIP4149
2BE19052 2BE19052
Explanation: Cache data exists for one or more
modified devices
Response: Contact your next level of support.
Failing Item:
2BE19076 2BE19076
v FI01105
Explanation: Missing auxiliary IOA or remote IOA
v STORIOA
Failing Item:
v SIP4147 2BE19082 2BE19082
Explanation: Device error
2BE19081 2BE19081
Response: If you are working with one of the card
Explanation: Device error types below, the adapter has mulitple physical parts.
Response: If you are working with one of the card Choose the card type to identify the physical parts of
types below, the adapter has mulitple physical parts. the storage adapter.
Choose the card type to identify the physical parts of Card type 2BE1 (feature RAID enablement card for
the storage adapter. embedded IOA) read the following: When working the
Card type 2BE1 (feature RAID enablement card for FRUs from the serviceable event or the failing item list
embedded IOA) read the following: When working the here, the embedded storage adapter (STORIOA) has
FRUs from the serviceable event or the failing item list three physical parts:
here, the embedded storage adapter (STORIOA) has v The embedded storage adapter on the I/O
three physical parts: backplane.
v The embedded storage adapter on the I/O v The RAID enablement card.
backplane. v The Battery charger and carrier card.
v The RAID enablement card.
v The Battery charger and carrier card. See symbolic FRU FEATCRD for the location codes of
the FRUs if they are not listed in the serviceable event
See symbolic FRU FEATCRD for the location codes of or if you are working the failing item list here.
the FRUs if they are not listed in the serviceable event
or if you are working the failing item list here. Card type 57CB (embedded IOA with 2BCF battery
card for embedded IOA) read the following: When
Card type 57CB (embedded IOA with 2BCF battery working the FRUs from the serviceable event or the
card for embedded IOA) read the following: When failing item list here, the embedded storage adapter
working the FRUs from the serviceable event or the (STORIOA) has two physical parts:
failing item list here, the embedded storage adapter v The embedded storage adapter on the I/O
(STORIOA) has two physical parts: backplane.
v The embedded storage adapter on the I/O v The Battery charger and carrier card.
backplane.
v The Battery charger and carrier card. See symbolic FRU FEATCRD for the location codes of
the FRUs if they are not listed in the serviceable event
See symbolic FRU FEATCRD for the location codes of or if you are working the failing item list here.
the FRUs if they are not listed in the serviceable event
or if you are working the failing item list here. Card type 57CF (embedded IOAs on DASD backplane
with 2BC2 dual battery charger and carrier card for the
Card type 57CF (embedded IOAs on DASD backplane embedded IOAs) read the following: When working
with 2BC2 dual battery charger and carrier card for the the FRUs from the serviceable event or the failing item
embedded IOAs) read the following: When working list here, the embedded storage adapters (STORIOA)
the FRUs from the serviceable event or the failing item have two physical parts:
list here, the embedded storage adapters (STORIOA) v The embedded storage adapter on the DASD
have two physical parts: backplane.
v The embedded storage adapter on the DASD v The dual battery charger and carrier card. To
backplane. determine which battery is connected to which
v The dual battery charger and carrier card. To embedded IOA use the bus number of the IOA with
determine which battery is connected to which symbolic FRU CACHBAT.
embedded IOA use the bus number of the IOA with
symbolic FRU CACHBAT. See symbolic FRU FEATCRD for the location code of
the dual battery charger and carrier card if it is not
See symbolic FRU FEATCRD for the location code of listed in the serviceable event or if you are working the
the dual battery charger and carrier card if it is not failing item list here.
listed in the serviceable event or if you are working the Failing Item:
failing item list here.
v FI01105
2BE19500 2BE19500
v STORIOA
Explanation: Internal program error in driver code.
2BE23109 2BE23109
Explanation: I/O adapter timed out a device
backplane command
Note: Use this table to handle reference codes that might be displayed during a
type D IPL to install the operating system. If you are not performing a type D IPL
of the operating system, consult any error logs that you find in the serviceable
event view. If you cannot locate an error log in the serviceable event view that
corresponds with the failure, run a verification test for the tape unit.
1. Verify that the device has power.
2. Check the 3494 Library Manager console for error indications. Refer to the 3494
service information to resolve any error indications.
3. Attempt the failing operation again.
4. Does the operation complete successfully?
Yes: The problem has been corrected. This ends the procedure.
No: Look at the 4 rightmost characters of the Data display for Function 11,
which represents the unit reference code. Find the unit reference code in the
following table.
v LIB3494
34942301 34942301
Explanation: Library device failure
34942307 34942307
Response: Library attachment facility equipment
Explanation: Library device failure
check.
Response: Library vision failure.
Use the 3494 Tape Library Dataserver Maintenance
Information and follow the procedures for analyzing a Use the 3494 Tape Library Dataserver Maintenance
"LIBRARY PROBLEM - NO ERROR MESSAGE." Information and follow the procedures for analyzing a
"LIBRARY PROBLEM - NO ERROR MESSAGE."
Failing Item:
v LIB3494 Failing Item:
v LIB3494
34942303 34942303
34942308 34942308
Explanation: Library device failure
Explanation: Library device failure
Response: Device control unit and library manager
Licensed Internal Code are incompatible. Response: Library manager equipment check.
Use the 3494 Tape Library Dataserver Maintenance Use the 3494 Tape Library Dataserver Maintenance
Information and follow the procedures for analyzing a Information and follow the procedures for analyzing a
"LIBRARY PROBLEM - NO ERROR MESSAGE." "LIBRARY MANAGER HARDWARE PROBLEM"
Failing Item: Failing Item:
v LIB3494 v LIB3494
Failing Item:
v LIB3494
34942310 34942310
Explanation: Library device requires operator
intervention
Response: Put the library into pause mode and
perform the intervention indicated on the library
manager console.
34942311 34942311
Explanation: Library device requires operator
intervention
Response: Put the library into pause mode and
perform the intervention indicated on the library
manager console.
34942319 34942319
Explanation: Tape unit failure
Response: Use the tape unit service information to
analyze the failure.
Failing Item:
v FI00851
34942321 34942321
Explanation: Library enclosure environmental alert
was detected.
Response: Use the 3494 Tape Library Dataserver
Maintenance Information and follow the procedures for
analyzing a "LIBRARY PROBLEM - NO ERROR
MESSAGE."
Failing Item:
v LIB3494
Note: Use this table to handle reference codes that might be displayed during a
type D IPL to install the operating system. If you are not performing a type D IPL
of the operating system, consult any error logs found in the serviceable event view.
If you cannot locate an error log in the serviceable event view that corresponds
with the failure, run a verification test for the tape unit.
1. Verify that the device has power.
2. Check the device for any error indications. Refer to the device service
information to resolve any error indications.
3. Clean the recording head in the tape device.
4. Attempt the failing operation again. Does the operation complete successfully?
Yes: You have corrected the problem. This ends the procedure.
No: Look at the 8 rightmost characters of the Data display for Function 11,
which represent the reference code. Find the reference code in the following
list.
v FI00872 v FI00871
v DEVTERM v FI01112
v SASCABL
35809101 35809101
Explanation: Fibre Channel interface error detected 35809200 35809200
Response: If the attached device is an external device, Explanation: Tape unit is not responding
do the following before exchanging any parts: Response: If the attached device is an external device,
1. Ensure that the Fibre Channel cable is correctly do the following before exchanging any parts:
connected to the ports. 1. Ensure that the device is powered on.
2. Clean the Fibre Channel connectors. 2. Ensure that the signal cable is seated correctly, and
3. If there is a switch or hub attached, verify that it is that there are no bent or damaged pins on the cable.
operational. 3. For a SCSI attached device ensure that a
4. If there is a gateway device attached, refer to the terminating plug is attached to the device end of
gateway device service documentation for the SCSI cable.
additional problem analysis procedures.
5. refer to the tape device service documentation for If the attached tape device is owned by a Virtual I/O
additional problem analysis procedures. Server partition refer to Troubleshooting the Virtual
I/O Server to determine the parts to replace.
If the attached tape device is owned by a Virtual I/O Failing Item:
Server partition refer to Troubleshooting the Virtual
v FI00871
I/O Server to determine the parts to replace.
v FI01112
Failing Item:
v FI00872
v FCIOA
v DEVTERM
v FCDEV
v FCCABLE
35809201 35809201
Explanation: Tape unit command timeout
35809102 35809102
Response: If the attached device is an external device,
Explanation: Gateway device detected a SCSI interface
do the following before exchanging any parts:
error
1. Ensure that the device is powered on.
Response: Use the gateway device service
2. If an interposer is required, make sure that it is
documentation to analyze the problem.
connected between the I/O processor and the SCSI
Failing Item: cable.
v FI00871 3. Ensure that the signal cable is seated correctly, and
v FCGATE that there are no bent or damaged pins on the SCSI
cable.
v FI00872
4. Ensure that a terminating plug is attached to the
v DEVTERM
device end of the SCSI cable.
5. If the attached tape device is owned by a Virtual
35809103 35809103 I/O Server partition it may be necessary to reset the
Explanation: Interface error detected by system or by virtual IOP to recover from the error.
tape unit Failing Item:
Response: If the attached device is an external tape v FI00871
device, do the following before exchanging any parts: v FI01112
1. Ensure that the SAS cable is correctly connected to v FI00872
the ports.
v DEVTERM
2. Ensure that the device has power.
v MEDIA
If the attached tape device is owned by a Virtual I/O
Server partition refer to Troubleshooting the Virtual
I/O Server to determine the parts to replace.
Failing Item:
Failing Item:
35809302 35809302
v FI00871
v FI01112 Explanation: Tape device failure or media error
Failing Item:
35809304 35809304
v FCGATE
v FCIOA Explanation: Tape unit failure
35809899 35809899
Explanation: Problem analysis completed, the problem
has been corrected.
Response: This reference code is used for ending
Online Problem Analysis when no problem was found
or the problem was corrected.
35809900 35809900
Explanation: Licensed Internal Code for tape unit was
not upgraded
Response: The I/O processor loading of Licensed
Internal Code (LIC) to the programmable tape unit was
not completed.
The tape unit will continue to operate with the
previous LIC. You may do either of the following:
v Wait for next IPL when the system will attempt to
load the LIC for the tape drive again.
v Perform TUPIP04 to reset the IOP and the tape unit.
When the IOP is reset, if the device has the wrong
level of LIC, the IOP will attempt to load the new
LIC.
Failing Item:
v USER
Note: Use this table to handle reference codes that might be displayed during a
type D IPL to install the operating system. If you are not performing a type D IPL
of the operating system, consult any error logs found in the serviceable event view.
If you cannot locate an error log in the serviceable event view that corresponds
with the failure, run a verification test for the tape unit.
1. Verify that the device has power.
2. Check the device for any error indications. Refer to the device service
information to resolve any error indications.
3. Clean the recording head in the tape device.
4. Attempt the failing operation again. Does the operation complete successfully?
Yes: You have corrected the problem. This ends the procedure.
No: Look at the 8 rightmost characters of the Data display for Function 11,
which represent the reference code. Find the reference code in the following
list.
v FI00872 v FI00871
v DEVTERM v FI01112
v SASCABL
35929101 35929101
Explanation: Fibre Channel interface error detected 35929200 35929200
Response: If the attached device is an external device, Explanation: Tape unit is not responding
do the following before exchanging any parts: Response: If the attached device is an external device,
1. Ensure that the Fibre Channel cable is correctly do the following before exchanging any parts:
connected to the ports. 1. Ensure that the device is powered on.
2. Clean the Fibre Channel connectors. 2. Ensure that the signal cable is seated correctly, and
3. If there is a switch or hub attached, verify that it is that there are no bent or damaged pins on the cable.
operational. 3. For a SCSI attached device ensure that a
4. If there is a gateway device attached, refer to the terminating plug is attached to the device end of
gateway device service documentation for the SCSI cable.
additional problem analysis procedures.
5. refer to the tape device service documentation for If the attached tape device is owned by a Virtual I/O
additional problem analysis procedures. Server partition refer to Troubleshooting the Virtual
I/O Server to determine the parts to replace.
If the attached tape device is owned by a Virtual I/O Failing Item:
Server partition refer to Troubleshooting the Virtual
v FI00871
I/O Server to determine the parts to replace.
v FI01112
Failing Item:
v FI00872
v FCIOA
v DEVTERM
v FCDEV
v FCCABLE
35929201 35929201
Explanation: Tape unit command timeout
35929102 35929102
Response: If the attached device is an external device,
Explanation: Gateway device detected a SCSI interface
do the following before exchanging any parts:
error
1. Ensure that the device is powered on.
Response: Use the gateway device service
2. If an interposer is required, make sure that it is
documentation to analyze the problem.
connected between the I/O processor and the SCSI
Failing Item: cable.
v FI00871 3. Ensure that the signal cable is seated correctly, and
v FCGATE that there are no bent or damaged pins on the SCSI
cable.
v FI00872
4. Ensure that a terminating plug is attached to the
v DEVTERM
device end of the SCSI cable.
5. If the attached tape device is owned by a Virtual
35929103 35929103 I/O Server partition it may be necessary to reset the
Explanation: Interface error detected by system or by virtual IOP to recover from the error.
tape unit Failing Item:
Response: If the attached device is an external tape v FI00871
device, do the following before exchanging any parts: v FI01112
1. Ensure that the SAS cable is correctly connected to v FI00872
the ports.
v DEVTERM
2. Ensure that the device has power.
v MEDIA
If the attached tape device is owned by a Virtual I/O
Server partition refer to Troubleshooting the Virtual
I/O Server to determine the parts to replace.
Failing Item:
Failing Item:
35929302 35929302
v FI00871
v FI01112 Explanation: Tape device failure or media error
Failing Item:
35929304 35929304
v FCGATE
v FCIOA Explanation: Tape unit failure
35929899 35929899
Explanation: Problem analysis completed, the problem
has been corrected.
Response: This reference code is used for ending
Online Problem Analysis when no problem was found
or the problem was corrected.
35929900 35929900
Explanation: Licensed Internal Code for tape unit was
not upgraded
Response: The I/O processor loading of Licensed
Internal Code (LIC) to the programmable tape unit was
not completed.
The tape unit will continue to operate with the
previous LIC. You may do either of the following:
v Wait for next IPL when the system will attempt to
load the LIC for the tape drive again.
v Perform TUPIP04 to reset the IOP and the tape unit.
When the IOP is reset, if the device has the wrong
level of LIC, the IOP will attempt to load the new
LIC.
Failing Item:
v USER
43203010 43203010
43203110 43203110
Explanation: Disk device returned wrong response to
IOA Explanation: Disk bus interface error occurred
Explanation: A device replacement has occurred Explanation: Device or IOA Licensed Internal Code
Response: No action required. This reference code is Response: The device does not support a needed
logged for information only. attribute and is running with degraded performance.
Contact your next level of support.
Explanation: Disk media format not valid Response: If this event appears in a serviceable event
view, work with the failing item list found there. If this
Failing Item: event does not appear in a serviceable event view, no
v DISKDRV service action is required.
Failing Item:
4320FFF4 4320FFF4 v DISKDRV
Explanation: Disk device problem
Failing Item: 4320FFFA 4320FFFA
4320FFFB 4320FFFB
Explanation: SCSI bus reset occurred
Response: No action required. This reference code is
logged for information only.
4320FFFE 4320FFFE
Explanation: Temporary disk bus error
Response: If this event appears in a serviceable event
view, work with the failing item list found there. If this
event does not appear in a serviceable event view, no
service action is required.
Failing Item:
v DISKDRV
v STORIOA
v FI01106
v FI01140
43223010 43223010
43223110 43223110
Explanation: Disk device returned wrong response to
IOA Explanation: Disk bus interface error occurred
Explanation: A device replacement has occurred Explanation: Device or IOA Licensed Internal Code
Response: No action required. This reference code is Response: The device does not support a needed
logged for information only. attribute and is running with degraded performance.
Contact your next level of support.
Explanation: Disk media format not valid Response: If this event appears in a serviceable event
view, work with the failing item list found there. If this
Failing Item: event does not appear in a serviceable event view, no
v DISKDRV service action is required.
Failing Item:
4322FFF4 4322FFF4 v DISKDRV
Explanation: Disk device problem
Failing Item: 4322FFFA 4322FFFA
4322FFFB 4322FFFB
Explanation: SCSI bus reset occurred
Response: No action required. This reference code is
logged for information only.
4322FFFE 4322FFFE
Explanation: Temporary disk bus error
Response: If this event appears in a serviceable event
view, work with the failing item list found there. If this
event does not appear in a serviceable event view, no
service action is required.
Failing Item:
v DISKDRV
v STORIOA
v FI01106
v FI01140
43233010 43233010
43233110 43233110
Explanation: Disk device returned wrong response to
IOA Explanation: Disk bus interface error occurred
Explanation: A device replacement has occurred Explanation: Device or IOA Licensed Internal Code
Response: No action required. This reference code is Response: The device does not support a needed
logged for information only. attribute and is running with degraded performance.
Contact your next level of support.
Explanation: Disk media format not valid Response: If this event appears in a serviceable event
view, work with the failing item list found there. If this
Failing Item: event does not appear in a serviceable event view, no
v DISKDRV service action is required.
Failing Item:
4323FFF4 4323FFF4 v DISKDRV
Explanation: Disk device problem
Failing Item: 4323FFFA 4323FFFA
4323FFFB 4323FFFB
Explanation: SCSI bus reset occurred
Response: No action required. This reference code is
logged for information only.
4323FFFE 4323FFFE
Explanation: Temporary disk bus error
Response: If this event appears in a serviceable event
view, work with the failing item list found there. If this
event does not appear in a serviceable event view, no
service action is required.
Failing Item:
v DISKDRV
v STORIOA
v FI01106
v FI01140
43253010 43253010
43253110 43253110
Explanation: Disk device returned wrong response to
IOA Explanation: Disk bus interface error occurred
Explanation: A device replacement has occurred Explanation: Device or IOA Licensed Internal Code
Response: No action required. This reference code is Response: The device does not support a needed
logged for information only. attribute and is running with degraded performance.
Contact your next level of support.
Explanation: Disk media format not valid Response: If this event appears in a serviceable event
view, work with the failing item list found there. If this
Failing Item: event does not appear in a serviceable event view, no
v DISKDRV service action is required.
Failing Item:
4325FFF4 4325FFF4 v DISKDRV
Explanation: Disk device problem
Failing Item: 4325FFFA 4325FFFA
4325FFFB 4325FFFB
Explanation: SCSI bus reset occurred
Response: No action required. This reference code is
logged for information only.
4325FFFE 4325FFFE
Explanation: Temporary disk bus error
Response: If this event appears in a serviceable event
view, work with the failing item list found there. If this
event does not appear in a serviceable event view, no
service action is required.
Failing Item:
v DISKDRV
v STORIOA
v FI01106
v FI01140
43263010 43263010
43263110 43263110
Explanation: Disk device returned wrong response to
IOA Explanation: Disk bus interface error occurred
Explanation: A device replacement has occurred Explanation: Device or IOA Licensed Internal Code
Response: No action required. This reference code is Response: The device does not support a needed
logged for information only. attribute and is running with degraded performance.
Contact your next level of support.
Explanation: Disk media format not valid Response: If this event appears in a serviceable event
view, work with the failing item list found there. If this
Failing Item: event does not appear in a serviceable event view, no
v DISKDRV service action is required.
Failing Item:
4326FFF4 4326FFF4 v DISKDRV
Explanation: Disk device problem
Failing Item: 4326FFFA 4326FFFA
4326FFFB 4326FFFB
Explanation: SCSI bus reset occurred
Response: No action required. This reference code is
logged for information only.
4326FFFE 4326FFFE
Explanation: Temporary disk bus error
Response: If this event appears in a serviceable event
view, work with the failing item list found there. If this
event does not appear in a serviceable event view, no
service action is required.
Failing Item:
v DISKDRV
v STORIOA
v FI01106
v FI01140
43273010 43273010
43273110 43273110
Explanation: Disk device returned wrong response to
IOA Explanation: Disk bus interface error occurred
Explanation: A device replacement has occurred Explanation: Device or IOA Licensed Internal Code
Response: No action required. This reference code is Response: The device does not support a needed
logged for information only. attribute and is running with degraded performance.
Contact your next level of support.
Explanation: Disk media format not valid Response: If this event appears in a serviceable event
view, work with the failing item list found there. If this
Failing Item: event does not appear in a serviceable event view, no
v DISKDRV service action is required.
Failing Item:
4327FFF4 4327FFF4 v DISKDRV
Explanation: Disk device problem
Failing Item: 4327FFFA 4327FFFA
4327FFFB 4327FFFB
Explanation: SCSI bus reset occurred
Response: No action required. This reference code is
logged for information only.
4327FFFE 4327FFFE
Explanation: Temporary disk bus error
Response: If this event appears in a serviceable event
view, work with the failing item list found there. If this
event does not appear in a serviceable event view, no
service action is required.
Failing Item:
v DISKDRV
v STORIOA
v FI01106
v FI01140
43283010 43283010
43283110 43283110
Explanation: Disk device returned wrong response to
IOA Explanation: Disk bus interface error occurred
Explanation: A device replacement has occurred Explanation: Device or IOA Licensed Internal Code
Response: No action required. This reference code is Response: The device does not support a needed
logged for information only. attribute and is running with degraded performance.
Contact your next level of support.
Explanation: Disk media format not valid Response: If this event appears in a serviceable event
view, work with the failing item list found there. If this
Failing Item: event does not appear in a serviceable event view, no
v DISKDRV service action is required.
Failing Item:
4328FFF4 4328FFF4 v DISKDRV
Explanation: Disk device problem
Failing Item: 4328FFFA 4328FFFA
4328FFFB 4328FFFB
Explanation: SCSI bus reset occurred
Response: No action required. This reference code is
logged for information only.
4328FFFE 4328FFFE
Explanation: Temporary disk bus error
Response: If this event appears in a serviceable event
view, work with the failing item list found there. If this
event does not appear in a serviceable event view, no
service action is required.
Failing Item:
v DISKDRV
v STORIOA
v FI01106
v FI01140
Response: No action required. This reference code is Explanation: Device Licensed Internal Code
logged for information only. Response: The device is not supported with the level
of code currently on the system. Contact your next
433B3100 433B3100 level of support.
433BFFF4 433BFFF4
433B4060 433B4060
Explanation: Disk device problem
Explanation: Multipath redundancy level reduced
Failing Item:
Response: A redundant disk unit connection has
failed. v DISKDRV
v STORIOA
Failing Item:
v SIP3153
433BFFF5 433BFFF5
v SASCABL
v SASEXP Explanation: Disk sector read error
Response: If this event appears in a serviceable event
433B4061 433B4061 view, work with the failing item list found there. If this
event does not appear in a serviceable event view, no
Explanation: Multipath redundancy level increased service action is required.
Response: A redundant disk unit connection has been Failing Item:
restored. No service action is required.
v DISKDRV
433B4100 433B4100
433BFFF6 433BFFF6
Explanation: Device bus fabric error
Explanation: Disk device detected recoverable error
Failing Item:
Response: If this event appears in a serviceable event
v SIP3152 view, work with the failing item list found there. If this
v SASCABL event does not appear in a serviceable event view, no
v SASEXP service action is required.
433BFFFB 433BFFFB
Explanation: SAS bus reset occurred
Response: No action required. This reference code is
logged for information only.
433BFFFC 433BFFFC
Explanation: Soft device bus error.
Response: If this event appears in a serviceable event
view, work with the failing item list found there. If this
event does not appear in a serviceable event view, no
service action is required.
Failing Item:
v SIP3250
v DISKDRV
v STORIOA
433BFFFD 433BFFFD
Explanation: Soft device bus error.
Response: If this event appears in a serviceable event
view, work with the failing item list found there. If this
event does not appear in a serviceable event view, no
service action is required.
Failing Item:
v SIP3250
v DISKDRV
v STORIOA
Response: No action required. This reference code is Explanation: Device Licensed Internal Code
logged for information only. Response: The device is not supported with the level
of code currently on the system. Contact your next
433C3100 433C3100 level of support.
433CFFF4 433CFFF4
433C4060 433C4060
Explanation: Disk device problem
Explanation: Multipath redundancy level reduced
Failing Item:
Response: A redundant disk unit connection has
failed. v DISKDRV
v STORIOA
Failing Item:
v SIP3153
433CFFF5 433CFFF5
v SASCABL
v SASEXP Explanation: Disk sector read error
Response: If this event appears in a serviceable event
433C4061 433C4061 view, work with the failing item list found there. If this
event does not appear in a serviceable event view, no
Explanation: Multipath redundancy level increased service action is required.
Response: A redundant disk unit connection has been Failing Item:
restored. No service action is required.
v DISKDRV
433C4100 433C4100
433CFFF6 433CFFF6
Explanation: Device bus fabric error
Explanation: Disk device detected recoverable error
Failing Item:
Response: If this event appears in a serviceable event
v SIP3152 view, work with the failing item list found there. If this
v SASCABL event does not appear in a serviceable event view, no
v SASEXP service action is required.
433CFFFB 433CFFFB
Explanation: SAS bus reset occurred
Response: No action required. This reference code is
logged for information only.
433CFFFC 433CFFFC
Explanation: Soft device bus error.
Response: If this event appears in a serviceable event
view, work with the failing item list found there. If this
event does not appear in a serviceable event view, no
service action is required.
Failing Item:
v SIP3250
v DISKDRV
v STORIOA
433CFFFD 433CFFFD
Explanation: Soft device bus error.
Response: If this event appears in a serviceable event
view, work with the failing item list found there. If this
event does not appear in a serviceable event view, no
service action is required.
Failing Item:
v SIP3250
v DISKDRV
v STORIOA
Response: No action required. This reference code is Explanation: Device Licensed Internal Code
logged for information only. Response: The device is not supported with the level
of code currently on the system. Contact your next
433D3100 433D3100 level of support.
433DFFF4 433DFFF4
433D4060 433D4060
Explanation: Disk device problem
Explanation: Multipath redundancy level reduced
Failing Item:
Response: A redundant disk unit connection has
failed. v DISKDRV
v STORIOA
Failing Item:
v SIP3153
433DFFF5 433DFFF5
v SASCABL
v SASEXP Explanation: Disk sector read error
Response: If this event appears in a serviceable event
433D4061 433D4061 view, work with the failing item list found there. If this
event does not appear in a serviceable event view, no
Explanation: Multipath redundancy level increased service action is required.
Response: A redundant disk unit connection has been Failing Item:
restored. No service action is required.
v DISKDRV
433D4100 433D4100
433DFFF6 433DFFF6
Explanation: Device bus fabric error
Explanation: Disk device detected recoverable error
Failing Item:
Response: If this event appears in a serviceable event
v SIP3152 view, work with the failing item list found there. If this
v SASCABL event does not appear in a serviceable event view, no
v SASEXP service action is required.
433DFFFB 433DFFFB
Explanation: SAS bus reset occurred
Response: No action required. This reference code is
logged for information only.
433DFFFC 433DFFFC
Explanation: Soft device bus error.
Response: If this event appears in a serviceable event
view, work with the failing item list found there. If this
event does not appear in a serviceable event view, no
service action is required.
Failing Item:
v SIP3250
v DISKDRV
v STORIOA
433DFFFD 433DFFFD
Explanation: Soft device bus error.
Response: If this event appears in a serviceable event
view, work with the failing item list found there. If this
event does not appear in a serviceable event view, no
service action is required.
Failing Item:
v SIP3250
v DISKDRV
v STORIOA
Note: Use this table to handle reference codes that might be displayed during a
type D IPL to install the operating system. If you are not performing a type D IPL
of the operating system, consult any error logs found in the serviceable event view.
If you cannot locate an error log in the serviceable event view that corresponds
with the failure, run a verification test for the tape unit.
1. Verify that the device has power.
2. Check the device for any error indications. Refer to the device service
information to resolve any error indications.
3. Clean the recording head in the tape device.
4. Attempt the failing operation again. Does the operation complete successfully?
Yes: You have corrected the problem. This ends the procedure.
No: Look at the 8 rightmost characters of the Data display for Function 11,
which represent the reference code. Find the reference code in the following
list.
v FI00872 v FI00871
v DEVTERM v FI01112
v SASCABL
46859101 46859101
Explanation: Fibre Channel interface error detected 46859200 46859200
Response: If the attached device is an external device, Explanation: Tape unit is not responding
do the following before exchanging any parts: Response: If the attached device is an external device,
1. Ensure that the Fibre Channel cable is correctly do the following before exchanging any parts:
connected to the ports. 1. Ensure that the device is powered on.
2. Clean the Fibre Channel connectors. 2. Ensure that the signal cable is seated correctly, and
3. If there is a switch or hub attached, verify that it is that there are no bent or damaged pins on the cable.
operational. 3. For a SCSI attached device ensure that a
4. If there is a gateway device attached, refer to the terminating plug is attached to the device end of
gateway device service documentation for the SCSI cable.
additional problem analysis procedures.
5. refer to the tape device service documentation for If the attached tape device is owned by a Virtual I/O
additional problem analysis procedures. Server partition refer to Troubleshooting the Virtual
I/O Server to determine the parts to replace.
If the attached tape device is owned by a Virtual I/O Failing Item:
Server partition refer to Troubleshooting the Virtual
v FI00871
I/O Server to determine the parts to replace.
v FI01112
Failing Item:
v FI00872
v FCIOA
v DEVTERM
v FCDEV
v FCCABLE
46859201 46859201
Explanation: Tape unit command timeout
46859102 46859102
Response: If the attached device is an external device,
Explanation: Gateway device detected a SCSI interface
do the following before exchanging any parts:
error
1. Ensure that the device is powered on.
Response: Use the gateway device service
2. If an interposer is required, make sure that it is
documentation to analyze the problem.
connected between the I/O processor and the SCSI
Failing Item: cable.
v FI00871 3. Ensure that the signal cable is seated correctly, and
v FCGATE that there are no bent or damaged pins on the SCSI
cable.
v FI00872
4. Ensure that a terminating plug is attached to the
v DEVTERM
device end of the SCSI cable.
5. If the attached tape device is owned by a Virtual
46859103 46859103 I/O Server partition it may be necessary to reset the
Explanation: Interface error detected by system or by virtual IOP to recover from the error.
tape unit Failing Item:
Response: If the attached device is an external tape v FI00871
device, do the following before exchanging any parts: v FI01112
1. Ensure that the SAS cable is correctly connected to v FI00872
the ports.
v DEVTERM
2. Ensure that the device has power.
v MEDIA
If the attached tape device is owned by a Virtual I/O
Server partition refer to Troubleshooting the Virtual
I/O Server to determine the parts to replace.
Failing Item:
Failing Item:
46859302 46859302
v FI00871
v FI01112 Explanation: Tape device failure or media error
Failing Item:
46859304 46859304
v FCGATE
v FCIOA Explanation: Tape unit failure
46859899 46859899
Explanation: Problem analysis completed, the problem
has been corrected.
Response: This reference code is used for ending
Online Problem Analysis when no problem was found
or the problem was corrected.
46859900 46859900
Explanation: Licensed Internal Code for tape unit was
not upgraded
Response: The I/O processor loading of Licensed
Internal Code (LIC) to the programmable tape unit was
not completed.
The tape unit will continue to operate with the
previous LIC. You may do either of the following:
v Wait for next IPL when the system will attempt to
load the LIC for the tape drive again.
v Perform TUPIP04 to reset the IOP and the tape unit.
When the IOP is reset, if the device has the wrong
level of LIC, the IOP will attempt to load the new
LIC.
Failing Item:
v USER
4758B991 4758B991
Explanation: Tampering of cryptographic card
suspected.
Failing Item:
v IOA
v FI00130
v IOP
4758B992 4758B992
Explanation: Operating voltage and/or temperature
range limits exceeded.
Response: Correct any conditions in the physical
environment which may have caused the voltage
and/or temperature out-of-range error on the 4758
adapter card. After the conditions have been corrected,
vary off and then vary back on the 4758 device
description associated with the 4758 adapter card.
Failing Item:
v CARDTMP
4764B991 4764B991
Explanation: Tampering of cryptographic card
suspected.
Failing Item:
v IOA
v AJDG301
4764B992 4764B992
Explanation: Operating voltage and/or temperature
range limits exceeded.
Response: Correct any conditions in the physical
environment which may have caused the voltage
and/or temperature out-of-range error on the 4764 /
4765 adapter card. After the conditions have been
corrected, vary off and then vary back on the 4764 /
4765 device description associated with the 4764 / 4765
adapter card.
Failing Item:
v CARDTMP
4765B991 4765B991
Explanation: Tampering of cryptographic card
suspected.
Failing Item:
v IOA
v AJDG301
4765B992 4765B992
Explanation: Operating voltage and/or temperature
range limits exceeded.
Response: Correct any conditions in the physical
environment which may have caused the voltage
and/or temperature out-of-range error on the 4764 /
4765 adapter card. After the conditions have been
corrected, vary off and then vary back on the 4764 /
4765 device description associated with the 4764 / 4765
adapter card.
Failing Item:
v CARDTMP
Explanation: I/O processor resource not available Explanation: Windows initiated a warm boot
Explanation: A permanent I/O processor failure Explanation: A Windows fatal error occurred
occurred Failing Item:
Failing Item: v IOA
v FI00730 v FI00730
v IOA
48126502 48126502
48126223 48126223 Explanation: A Windows fatal error occurred
Explanation: A permanent I/O processor failure Failing Item:
occurred
v FI00730
v IOA
48126538 48126538
Explanation: A Virtual SCSI error was detected.
48126530 48126530
Failing Item:
Explanation: A Virtual SCSI error was detected.
v NTVSCSI
Failing Item:
v NTOPSYS
v NTVSCSI
v NTOPSYS
48126539 48126539
Explanation: A Virtual SCSI error was detected.
48126531 48126531
Failing Item:
Explanation: A Virtual SCSI error was detected.
v NTVSCSI
Failing Item:
v AS4NTDD
v NTVSCSI
v NTOPSYS
v AS4NTDD
v FI00730
v NTOPSYS
v FI00730
4812653A 4812653A
Explanation: A Virtual SCSI error was detected.
48126532 48126532
Failing Item:
Explanation: A Virtual SCSI error was detected.
v NTOPSYS
Failing Item:
v FI00730
v NTOPSYS
v AS4NTDD
v FI00730
v AS4NTDD
4812653B 4812653B
Explanation: A Virtual SCSI error was detected.
48126533 48126533
Failing Item:
Explanation: A Virtual SCSI error was detected.
v NTUSER
Failing Item:
v NTOPSYS
v NTUSER
v AS4NTDD
v NTOPSYS
v AS4NTDD
4812653C 4812653C
Explanation: A Virtual SCSI error was detected.
48126534 48126534
Failing Item:
Explanation: A Virtual SCSI error was detected.
v AS4NTDD
Failing Item:
v FI00730
v AS4NTDD
v NTOPSYS
v FI00730
v NTOPSYS
4812653D 4812653D
Explanation: A Virtual SCSI error was detected.
48126535 48126535
Failing Item:
Explanation: A Virtual SCSI error was detected.
v NTUSER
Failing Item:
v NTDEVDR
v NTUSER
v FI00730
v NTDEVDR
v FI00730
4812B904 4812B904
Explanation: A permanent I/O processor failure
occurred
Failing Item:
v FI00730
v IOA
4812B960 4812B960
Explanation: I/O processor Licensed Internal Code
error
Failing Item:
v FI00730
v IOP
506D8401 506D8401
Explanation: Removable media power fault
Failing Item:
v DEVBPLN
506D8404 506D8404
Explanation: System log entry only, no service action
required
506DFFF4 506DFFF4
Explanation: Device backplane problem
Failing Item:
v DEVBPLN
v STORIOA
v FI01140
v FI01106
506E8401 506E8401
Explanation: Removable media power fault
Failing Item:
v DEVBPLN
506E8404 506E8404
Explanation: System log entry only, no service action
required
506EFFF4 506EFFF4
Explanation: Device backplane problem
Failing Item:
v DEVBPLN
v STORIOA
v FI01140
v FI01106
509A8404 509A8404
Explanation: System log entry only, no service action
required
509AFFF4 509AFFF4
Explanation: Device backplane problem
Failing Item:
v SASEXP
v SASCABL
v STORIOA
v DEVBPLN
509D1515 509D1515
Explanation: A fatal error occurred on power supply 1
Failing Item:
v DISKPWR
v SASEXP
509D3002 509D3002
Explanation: Addressed device backplane failed to
respond to selection
Failing Item:
v SASEXP
v SASCABL
v STORIOA
509D3109 509D3109
Explanation: I/O adapter timed out a device
backplane command
Failing Item:
v SASEXP
v SASCABL
v STORIOA
509D7614 509D7614
Explanation: A fatal error occurred on fan 1
Failing Item:
v DISKFAN
509D8404 509D8404
Explanation: System log entry only, no service action
required
509DFFF4 509DFFF4
Explanation: Device backplane problem
Failing Item:
v SASEXP
50A48404 50A48404
Explanation: System log entry only, no service action
required
50A4FFF4 50A4FFF4
Explanation: Device backplane problem
Failing Item:
v SASEXP
v SASCABL
v STORIOA
v DEVBPLN
Note: Use this table to handle reference codes that might be displayed during a
type D IPL to install the operating system. If you are not performing a type D IPL
of the operating system, consult any error logs found in the serviceable event view.
If you cannot locate an error log in the serviceable event view that corresponds
with the failure, run a verification test for the tape unit.
1. Verify that the device has power.
2. Check the device for any error indications. Refer to the device service
information to resolve any error indications.
3. Clean the recording head in the tape device.
4. Attempt the failing operation again. Does the operation complete successfully?
Yes: You have corrected the problem. This ends the procedure.
No: Look at the 8 rightmost characters of the Data display for Function 11,
which represent the reference code. Find the reference code in the following
list.
v FI00872 v FI00871
v DEVTERM v FI01112
v SASCABL
56199101 56199101
Explanation: Fibre Channel interface error detected 56199200 56199200
Response: If the attached device is an external device, Explanation: Tape unit is not responding
do the following before exchanging any parts: Response: If the attached device is an external device,
1. Ensure that the Fibre Channel cable is correctly do the following before exchanging any parts:
connected to the ports. 1. Ensure that the device is powered on.
2. Clean the Fibre Channel connectors. 2. Ensure that the signal cable is seated correctly, and
3. If there is a switch or hub attached, verify that it is that there are no bent or damaged pins on the cable.
operational. 3. For a SCSI attached device ensure that a
4. If there is a gateway device attached, refer to the terminating plug is attached to the device end of
gateway device service documentation for the SCSI cable.
additional problem analysis procedures.
5. refer to the tape device service documentation for If the attached tape device is owned by a Virtual I/O
additional problem analysis procedures. Server partition refer to Troubleshooting the Virtual
I/O Server to determine the parts to replace.
If the attached tape device is owned by a Virtual I/O Failing Item:
Server partition refer to Troubleshooting the Virtual
v FI00871
I/O Server to determine the parts to replace.
v FI01112
Failing Item:
v FI00872
v FCIOA
v DEVTERM
v FCDEV
v FCCABLE
56199201 56199201
Explanation: Tape unit command timeout
56199102 56199102
Response: If the attached device is an external device,
Explanation: Gateway device detected a SCSI interface
do the following before exchanging any parts:
error
1. Ensure that the device is powered on.
Response: Use the gateway device service
2. If an interposer is required, make sure that it is
documentation to analyze the problem.
connected between the I/O processor and the SCSI
Failing Item: cable.
v FI00871 3. Ensure that the signal cable is seated correctly, and
v FCGATE that there are no bent or damaged pins on the SCSI
cable.
v FI00872
4. Ensure that a terminating plug is attached to the
v DEVTERM
device end of the SCSI cable.
5. If the attached tape device is owned by a Virtual
56199103 56199103 I/O Server partition it may be necessary to reset the
Explanation: Interface error detected by system or by virtual IOP to recover from the error.
tape unit Failing Item:
Response: If the attached device is an external tape v FI00871
device, do the following before exchanging any parts: v FI01112
1. Ensure that the SAS cable is correctly connected to v FI00872
the ports.
v DEVTERM
2. Ensure that the device has power.
v MEDIA
If the attached tape device is owned by a Virtual I/O
Server partition refer to Troubleshooting the Virtual
I/O Server to determine the parts to replace.
Failing Item:
Failing Item:
56199302 56199302
v FI00871
v FI01112 Explanation: Tape device failure or media error
Failing Item:
56199304 56199304
v FCGATE
v FCIOA Explanation: Tape unit failure
56199899 56199899
Explanation: Problem analysis completed, the problem
has been corrected.
Response: This reference code is used for ending
Online Problem Analysis when no problem was found
or the problem was corrected.
56199900 56199900
Explanation: Licensed Internal Code for tape unit was
not upgraded
Response: The I/O processor loading of Licensed
Internal Code (LIC) to the programmable tape unit was
not completed.
The tape unit will continue to operate with the
previous LIC. You may do either of the following:
v Wait for next IPL when the system will attempt to
load the LIC for the tape drive again.
v Perform TUPIP04 to reset the IOP and the tape unit.
When the IOP is reset, if the device has the wrong
level of LIC, the IOP will attempt to load the new
LIC.
Failing Item:
v USER
Note: Use this table to handle reference codes that might be displayed during a
type D IPL to install the operating system. If you are not performing a type D IPL
of the operating system, consult any error logs found in the serviceable event view.
If you cannot locate an error log in the serviceable event view that corresponds
with the failure, run a verification test for the tape unit.
1. Verify that the device has power.
2. Check the device for any error indications. Refer to the device service
information to resolve any error indications.
3. Clean the recording head in the tape device.
4. Attempt the failing operation again. Does the operation complete successfully?
Yes: You have corrected the problem. This ends the procedure.
No: Look at the 8 rightmost characters of the Data display for Function 11,
which represent the reference code. Find the reference code in the following
list.
v FI00872 v FI00871
v DEVTERM v FI01112
v SASCABL
56389101 56389101
Explanation: Fibre Channel interface error detected 56389200 56389200
Response: If the attached device is an external device, Explanation: Tape unit is not responding
do the following before exchanging any parts: Response: If the attached device is an external device,
1. Ensure that the Fibre Channel cable is correctly do the following before exchanging any parts:
connected to the ports. 1. Ensure that the device is powered on.
2. Clean the Fibre Channel connectors. 2. Ensure that the signal cable is seated correctly, and
3. If there is a switch or hub attached, verify that it is that there are no bent or damaged pins on the cable.
operational. 3. For a SCSI attached device ensure that a
4. If there is a gateway device attached, refer to the terminating plug is attached to the device end of
gateway device service documentation for the SCSI cable.
additional problem analysis procedures.
5. refer to the tape device service documentation for If the attached tape device is owned by a Virtual I/O
additional problem analysis procedures. Server partition refer to Troubleshooting the Virtual
I/O Server to determine the parts to replace.
If the attached tape device is owned by a Virtual I/O Failing Item:
Server partition refer to Troubleshooting the Virtual
v FI00871
I/O Server to determine the parts to replace.
v FI01112
Failing Item:
v FI00872
v FCIOA
v DEVTERM
v FCDEV
v FCCABLE
56389201 56389201
Explanation: Tape unit command timeout
56389102 56389102
Response: If the attached device is an external device,
Explanation: Gateway device detected a SCSI interface
do the following before exchanging any parts:
error
1. Ensure that the device is powered on.
Response: Use the gateway device service
2. If an interposer is required, make sure that it is
documentation to analyze the problem.
connected between the I/O processor and the SCSI
Failing Item: cable.
v FI00871 3. Ensure that the signal cable is seated correctly, and
v FCGATE that there are no bent or damaged pins on the SCSI
cable.
v FI00872
4. Ensure that a terminating plug is attached to the
v DEVTERM
device end of the SCSI cable.
5. If the attached tape device is owned by a Virtual
56389103 56389103 I/O Server partition it may be necessary to reset the
Explanation: Interface error detected by system or by virtual IOP to recover from the error.
tape unit Failing Item:
Response: If the attached device is an external tape v FI00871
device, do the following before exchanging any parts: v FI01112
1. Ensure that the SAS cable is correctly connected to v FI00872
the ports.
v DEVTERM
2. Ensure that the device has power.
v MEDIA
If the attached tape device is owned by a Virtual I/O
Server partition refer to Troubleshooting the Virtual
I/O Server to determine the parts to replace.
Failing Item:
Failing Item:
56389302 56389302
v FI00871
v FI01112 Explanation: Tape device failure or media error
Failing Item:
56389304 56389304
v FCGATE
v FCIOA Explanation: Tape unit failure
56389899 56389899
Explanation: Problem analysis completed, the problem
has been corrected.
Response: This reference code is used for ending
Online Problem Analysis when no problem was found
or the problem was corrected.
56389900 56389900
Explanation: Licensed Internal Code for tape unit was
not upgraded
Response: The I/O processor loading of Licensed
Internal Code (LIC) to the programmable tape unit was
not completed.
The tape unit will continue to operate with the
previous LIC. You may do either of the following:
v Wait for next IPL when the system will attempt to
load the LIC for the tape drive again.
v Perform TUPIP04 to reset the IOP and the tape unit.
When the IOP is reset, if the device has the wrong
level of LIC, the IOP will attempt to load the new
LIC.
Failing Item:
v USER
Note: Use this table to handle reference codes that might be displayed during a
type D IPL to install the operating system. If you are not performing a type D IPL
of the operating system, consult any error logs found in the serviceable event view.
If you cannot locate an error log in the serviceable event view that corresponds
with the failure, run a verification test for the tape unit.
1. Verify that the device has power.
2. Check the device for any error indications. Refer to the device service
information to resolve any error indications.
3. Clean the recording head in the tape device.
4. Attempt the failing operation again. Does the operation complete successfully?
Yes: You have corrected the problem. This ends the procedure.
No: Look at the 8 rightmost characters of the Data display for Function 11,
which represent the reference code. Find the reference code in the following
list.
v FI00872 v FI00871
v DEVTERM v FI01112
v SASCABL
56759101 56759101
Explanation: Fibre Channel interface error detected 56759200 56759200
Response: If the attached device is an external device, Explanation: Tape unit is not responding
do the following before exchanging any parts: Response: If the attached device is an external device,
1. Ensure that the Fibre Channel cable is correctly do the following before exchanging any parts:
connected to the ports. 1. Ensure that the device is powered on.
2. Clean the Fibre Channel connectors. 2. Ensure that the signal cable is seated correctly, and
3. If there is a switch or hub attached, verify that it is that there are no bent or damaged pins on the cable.
operational. 3. For a SCSI attached device ensure that a
4. If there is a gateway device attached, refer to the terminating plug is attached to the device end of
gateway device service documentation for the SCSI cable.
additional problem analysis procedures.
5. refer to the tape device service documentation for If the attached tape device is owned by a Virtual I/O
additional problem analysis procedures. Server partition refer to Troubleshooting the Virtual
I/O Server to determine the parts to replace.
If the attached tape device is owned by a Virtual I/O Failing Item:
Server partition refer to Troubleshooting the Virtual
v FI00871
I/O Server to determine the parts to replace.
v FI01112
Failing Item:
v FI00872
v FCIOA
v DEVTERM
v FCDEV
v FCCABLE
56759201 56759201
Explanation: Tape unit command timeout
56759102 56759102
Response: If the attached device is an external device,
Explanation: Gateway device detected a SCSI interface
do the following before exchanging any parts:
error
1. Ensure that the device is powered on.
Response: Use the gateway device service
2. If an interposer is required, make sure that it is
documentation to analyze the problem.
connected between the I/O processor and the SCSI
Failing Item: cable.
v FI00871 3. Ensure that the signal cable is seated correctly, and
v FCGATE that there are no bent or damaged pins on the SCSI
cable.
v FI00872
4. Ensure that a terminating plug is attached to the
v DEVTERM
device end of the SCSI cable.
5. If the attached tape device is owned by a Virtual
56759103 56759103 I/O Server partition it may be necessary to reset the
Explanation: Interface error detected by system or by virtual IOP to recover from the error.
tape unit Failing Item:
Response: If the attached device is an external tape v FI00871
device, do the following before exchanging any parts: v FI01112
1. Ensure that the SAS cable is correctly connected to v FI00872
the ports.
v DEVTERM
2. Ensure that the device has power.
v MEDIA
If the attached tape device is owned by a Virtual I/O
Server partition refer to Troubleshooting the Virtual
I/O Server to determine the parts to replace.
Failing Item:
Failing Item:
56759302 56759302
v FI00871
v FI01112 Explanation: Tape device failure or media error
Failing Item:
56759304 56759304
v FCGATE
v FCIOA Explanation: Tape unit failure
56759899 56759899
Explanation: Problem analysis completed, the problem
has been corrected.
Response: This reference code is used for ending
Online Problem Analysis when no problem was found
or the problem was corrected.
56759900 56759900
Explanation: Licensed Internal Code for tape unit was
not upgraded
Response: The I/O processor loading of Licensed
Internal Code (LIC) to the programmable tape unit was
not completed.
The tape unit will continue to operate with the
previous LIC. You may do either of the following:
v Wait for next IPL when the system will attempt to
load the LIC for the tape drive again.
v Perform TUPIP04 to reset the IOP and the tape unit.
When the IOP is reset, if the device has the wrong
level of LIC, the IOP will attempt to load the new
LIC.
Failing Item:
v USER
5700B9A0 5700B9A0
Explanation: I/O adapter hardware error detected
Failing Item:
v FI00719
v FI00718
v AJDGP01
v MA_BRDG
5700B9B0 5700B9B0
Explanation: I/O adapter hardware error detected
Failing Item:
v FI00719
v AJDG301
v MA_BRDG
5701B9A0 5701B9A0
Explanation: I/O adapter hardware error detected
Failing Item:
v FI00719
v FI00718
v AJDGP01
v MA_BRDG
5701B9B0 5701B9B0
Explanation: I/O adapter hardware error detected
Failing Item:
v FI00719
v AJDG301
v MA_BRDG
v AJDGP01 v USER
v IOP v FI01105
v FI01104
v BACKPLN 57022202 57022202
Explanation: Removable media error during IPL
57021307 57021307 Failing Item:
Explanation: I/O processor resource not available v FI00022
Failing Item: v FI01105
v AJDGP01
v AJDG301 57023000 57023000
Explanation: A permanent I/O processor failure
57021310 57021310 occurred
v FI01101 v IOPIP17
v IOP v USER
v MA_BRDG v FI01107
v STORIOA
57023001 57023001
Explanation: Not valid condition in I/O Processor 57023022 57023022
Licensed Internal Code Explanation: I/O processor detected a SCSI bus
Response: The Licensed Internal Code found a configuration error
condition that should not have occurred. Response: Error occurred on SCSI bus 2.
Failing Item: Failing Item:
v IOP v IOPIP17
v AJDGP01 v USER
v FI01107
57023002 57023002 v STORIOA
Explanation: Addressed device failed to respond to
selection 57023023 57023023
Failing Item: Explanation: I/O processor detected a SCSI bus
v IOPIP16 configuration error
v FI01105 Response: Error occurred on SCSI bus 3.
v STORIOA
Failing Item:
v FI01140
v IOPIP17
v FI01141
v USER
v FI01106
v FI01107
v STORIOA
57023006 57023006
Explanation: System bus error 57023080 57023080
Failing Item: Explanation: I/O processor Licensed Internal Code
v IOP error
v ANYBUS Failing Item:
v FI01101 v AJDGP01
Failing Item:
57023102 57023102
57023120 57023120
Explanation: I/O processor card detected interface
error Explanation: I/O Processor detected that the bus is
not operational
Response: Error occurred on SCSI bus 2.
Response: A device was added to SCSI bus 0 of the
Failing Item: I/O Adapter and caused the bus to become not
v IOPIP13 operational. Remove the device.
v FI01107 Failing Item:
v STORIOA v SVCDOCS
v FI01140
v DEVBPLN 57023121 57023121
Explanation: I/O Processor detected that the bus is
not operational
Response: A device was added to SCSI bus 1 of the
I/O Adapter and caused the bus to become not
Explanation: I/O Processor detected that the bus is Response: This reference code and the 3123 reference
not operational code that occurred before it require no service action,
since SCSI bus 3 is now operational.
Response: A device was added to SCSI bus 2 of the
I/O Adapter and caused the bus to become not
operational. Remove the device. 57023150 57023150
Explanation: I/O Processor detected that the bus is Explanation: Disk media format bad
now operational Failing Item:
Response: This reference code and the 3121 reference v FI01105
code that occurred before it require no service action,
since SCSI bus 1 is now operational.
57023205 57023205
Explanation: Disk sector read error
57023142 57023142
Response: Disk unit data may need to be reloaded,
Explanation: I/O Processor detected that the bus is
but the disk unit does not need to be replaced.
now operational
Failing Item:
Response: This reference code and the 3122 reference
code that occurred before it require no service action, v FI01105
57023250 57023250
57026070 57026070
Explanation: Disk unit requires initialization before
use. Explanation: A permanent I/O processor failure
occurred
Response: Perform a D-IPL and work on errors found
in the log. Failing Item:
v IOP
Failing Item:
v USER
57026071 57026071
57026075 57026075
57023401 57023401
Explanation: I/O processor resource not available
Explanation: Device backplane problem
Failing Item:
Failing Item:
v AJDGP01
v DEVBPLN
57026076 57026076
57023501 57023501
Explanation: I/O processor card detected media error
Explanation: I/O processor Licensed Internal Code
error Failing Item:
Failing Item: v MEDIA
v AJDGP01 v AJDGP01
v IOP v FI01105
Response: No action required. Protection will be Explanation: IOP resources not available due to
automatically restarted. previous problems.
Response: Power off the system and remove all new
57029041 57029041 or replacement disk units. IPL the system to DST. If
you cannot perform a type A or B IPL, perform a type
Explanation: Background array parity check detected D IPL from removable media.
and corrected errors
Look for Product Activity Log entries for other IOP
Response: Call your next level of support to report reference codes and take action on them.
the problem.
Failing Item:
Failing Item:
v SVCDOCS
v AJDGP01
57029081 57029081
57029050 57029050
Explanation: I/O processor card detected device error
Explanation: Required cache data cannot be located
for a disk unit. Failing Item:
v FI01105
Failing Item:
v STORIOA
v IOPIP30
v IOP
5702BE00 5702BE00
Explanation: I/O processor detected a fault condition
5702B3E0 5702B3E0
Failing Item:
Explanation: I/O processor detected a fault condition
v AJDGP01
Failing Item:
v IOP
v IOP
v FI01104
v MA_BRDG
v MA_BRDG
5702B3E1 5702B3E1
5702FF3D 5702FF3D
Explanation: I/O processor detected a fault condition
Explanation: I/O adapter detected recoverable error
Failing Item:
Failing Item:
v IOP
v STORIOA
v MA_BRDG
v ANYBRDG
5702B410 5702B410
5702FF6D 5702FF6D
Explanation: A permanent I/O processor failure
Explanation: I/O processor detected a recoverable
occurred
system bus error
Failing Item:
Failing Item:
v STORIOA
v IOP
v ANYBUS
5702B411 5702B411
Explanation: A permanent I/O processor failure
occurred
Failing Item:
v STORIOA
5702B412 5702B412
Explanation: Tape/CD or disk bus interface error
occurred
Failing Item:
v IOPIP16
v FI01107
v FI01140
v STORIOA
v DEVTERM
5702B935 5702B935
Explanation: Unknown hardware detected
Failing Item:
v FI01101
v AJDGP01
v IOP
v MA_BRDG
Explanation: I/O processor detected a SCSI bus Response: Error occurred on SCSI bus 0.
configuration error Failing Item:
Response: Error occurred on SCSI bus 0. v IOPIP13
Failing Item: v FI01107
v IOPIP17 v STORIOA
v USER v FI01140
v FI01107 v DEVBPLN
v STORIOA
57033101 57033101
57033021 57033021 Explanation: I/O processor card detected interface
error
Explanation: I/O processor detected a SCSI bus
configuration error Response: Error occurred on SCSI bus 1.
Response: Error occurred on SCSI bus 1. Failing Item:
Failing Item: v IOPIP13
v IOPIP17 v FI01107
v USER v STORIOA
v FI01107 v FI01140
v STORIOA v DEVBPLN
Explanation: I/O processor detected a SCSI bus Explanation: I/O processor card detected interface
configuration error error
Response: Error occurred on SCSI bus 2. Response: Error occurred on SCSI bus 2.
v FI01140 v SVCDOCS
v DEVBPLN
57033140 57033140
57033103 57033103 Explanation: I/O Processor detected that the bus is
Explanation: I/O processor card detected interface now operational
error Response: This reference code and the 3120 reference
Response: Error occurred on SCSI bus 3. code that occurred before it require no service action,
since SCSI bus 0 is now operational.
Failing Item:
v IOPIP13
57033141 57033141
v FI01107
Explanation: I/O Processor detected that the bus is
v STORIOA
now operational
v FI01140
Response: This reference code and the 3121 reference
v DEVBPLN
code that occurred before it require no service action,
since SCSI bus 1 is now operational.
57033120 57033120
Explanation: I/O Processor detected that the bus is 57033142 57033142
not operational
Explanation: I/O Processor detected that the bus is
Response: A device was added to SCSI bus 0 of the now operational
I/O Adapter and caused the bus to become not
Response: This reference code and the 3122 reference
operational. Remove the device.
code that occurred before it require no service action,
Failing Item: since SCSI bus 2 is now operational.
v SVCDOCS
57033143 57033143
57033121 57033121 Explanation: I/O Processor detected that the bus is
Explanation: I/O Processor detected that the bus is now operational
not operational Response: This reference code and the 3123 reference
Response: A device was added to SCSI bus 1 of the code that occurred before it require no service action,
I/O Adapter and caused the bus to become not since SCSI bus 3 is now operational.
operational. Remove the device.
Failing Item: 57033150 57033150
v ANYBRDG
5703FF6D 5703FF6D
Explanation: I/O processor detected a recoverable
system bus error
Failing Item:
v IOP
v ANYBUS
Explanation: A permanent I/O processor failure IPL the I/O processor, see Debug the resource. If an
occurred I/O processor reset and I/O processor IPL does not
resolve the problem, contact your next level of support.
Failing Item:
v FCIOA Failing Item:
v ANYBRDG v SVCDOCS
v OPT_CLN
5704FF3D 5704FF3D
57048151 57048151 Explanation: Recovered IOA error
Explanation: I/O processor Licensed Internal Code Failing Item:
error v FCIOA
Failing Item: v ANYBRDG
v AJDGP01 v OPT_CLN
v FCIOA
v IOP
v OPT_CLN
57048155 57048155
Explanation: A permanent I/O processor failure
occurred
Failing Item:
v AJDGP01
v FCIOA
v OPT_CLN
57048156 57048156
Explanation: A permanent I/O processor failure
occurred
Failing Item:
v AJDGP01
v FCIOA
v OPT_CLN
57049091 57049091
Explanation: Incorrect hardware configuration change
has been detected.
Response: Reset the I/O processor and then IPL the
I/O processor. For information about how to reset and
IPL the I/O processor, see Debug the resource. If an
I/O processor reset and I/O processor IPL does not
resolve the problem, contact your next level of support.
Failing Item:
v SVCDOCS
57049092 57049092
Explanation: Incorrect hardware configuration change
has been detected.
Response: Reset the I/O processor and then IPL the
I/O processor. For information about how to reset and
5706B9B0 5706B9B0
Explanation: I/O adapter hardware error detected
Failing Item:
v IOA
v AJDGP01
5707B9B0 5707B9B0
Explanation: I/O adapter hardware error detected
Failing Item:
v IOA
v AJDGP01
Response: Error occurred on SCSI bus 0. Explanation: Impending cache battery pack failure
Response: v AUXIOA
Failing Item:
57088302 57088302
v PTFSRCH
v AUXIOA Explanation: Missing Licensed Internal Code
Response: Ensure that the code necessary to support
57088156 57088156 this I/O adapter is loaded.
57089071 57089071
Explanation: Link from IOA to auxiliary cache IOA
went operational
Response: No service action required.
57089072 57089072
Explanation: Link from IOA to auxiliary cache IOA
went non-operational
Response: No service action required.
57089073 57089073
Explanation: Disconnected, incompatible, or
non-operational storage IOA
Response:
Failing Item:
v IOPIP41
5708FF3D 5708FF3D
Explanation: I/O adapter detected recoverable error
Response:
Failing Item:
v AUXIOA
v ANYBRDG
Explanation: I/O processor detected a SCSI bus Response: Error occurred on SCSI bus 0.
configuration error Failing Item:
Response: Error occurred on SCSI bus 0. v IOPIP13
Failing Item: v FI01107
v IOPIP17 v STORIOA
v USER v FI01140
v FI01107 v DEVBPLN
v STORIOA
57093101 57093101
57093021 57093021 Explanation: I/O processor card detected interface
error
Explanation: I/O processor detected a SCSI bus
configuration error Response: Error occurred on SCSI bus 1.
Response: Error occurred on SCSI bus 1. Failing Item:
Failing Item: v IOPIP13
v IOPIP17 v FI01107
v USER v STORIOA
v FI01107 v FI01140
v STORIOA v DEVBPLN
Explanation: I/O processor detected a SCSI bus Explanation: I/O processor card detected interface
configuration error error
Response: Error occurred on SCSI bus 2. Response: Error occurred on SCSI bus 2.
v FI01140 v SVCDOCS
v DEVBPLN
57093140 57093140
57093103 57093103 Explanation: I/O Processor detected that the bus is
Explanation: I/O processor card detected interface now operational
error Response: This reference code and the 3120 reference
Response: Error occurred on SCSI bus 3. code that occurred before it require no service action,
since SCSI bus 0 is now operational.
Failing Item:
v IOPIP13
57093141 57093141
v FI01107
Explanation: I/O Processor detected that the bus is
v STORIOA
now operational
v FI01140
Response: This reference code and the 3121 reference
v DEVBPLN
code that occurred before it require no service action,
since SCSI bus 1 is now operational.
57093120 57093120
Explanation: I/O Processor detected that the bus is 57093142 57093142
not operational
Explanation: I/O Processor detected that the bus is
Response: A device was added to SCSI bus 0 of the now operational
I/O Adapter and caused the bus to become not
Response: This reference code and the 3122 reference
operational. Remove the device.
code that occurred before it require no service action,
Failing Item: since SCSI bus 2 is now operational.
v SVCDOCS
57093143 57093143
57093121 57093121 Explanation: I/O Processor detected that the bus is
Explanation: I/O Processor detected that the bus is now operational
not operational Response: This reference code and the 3123 reference
Response: A device was added to SCSI bus 1 of the code that occurred before it require no service action,
I/O Adapter and caused the bus to become not since SCSI bus 3 is now operational.
operational. Remove the device.
Failing Item: 57093150 57093150
v ANYBRDG
5709FF6D 5709FF6D
Explanation: I/O processor detected a recoverable
system bus error
Failing Item:
v IOP
v ANYBUS
v AJDGP01 v USER
v IOP v FI01105
v FI01104
v BACKPLN 570B2202 570B2202
Explanation: Removable media error during IPL
570B1307 570B1307 Failing Item:
Explanation: I/O processor resource not available v FI00022
Failing Item: v FI01105
v AJDGP01
v AJDG301 570B3000 570B3000
Explanation: A permanent I/O processor failure
570B1310 570B1310 occurred
v FI01101 v IOPIP17
v IOP v USER
v MA_BRDG v FI01107
v STORIOA
570B3001 570B3001
Explanation: Not valid condition in I/O Processor 570B3022 570B3022
Licensed Internal Code Explanation: I/O processor detected a SCSI bus
Response: The Licensed Internal Code found a configuration error
condition that should not have occurred. Response: Error occurred on SCSI bus 2.
Failing Item: Failing Item:
v IOP v IOPIP17
v AJDGP01 v USER
v FI01107
570B3002 570B3002 v STORIOA
Explanation: Addressed device failed to respond to
selection 570B3023 570B3023
Failing Item: Explanation: I/O processor detected a SCSI bus
v IOPIP16 configuration error
v FI01105 Response: Error occurred on SCSI bus 3.
v STORIOA
Failing Item:
v FI01140
v IOPIP17
v FI01141
v USER
v FI01106
v FI01107
v STORIOA
570B3006 570B3006
Explanation: System bus error 570B3080 570B3080
Failing Item: Explanation: I/O processor Licensed Internal Code
v IOP error
v ANYBUS Failing Item:
v FI01101 v AJDGP01
Failing Item:
570B3102 570B3102
570B3120 570B3120
Explanation: I/O processor card detected interface
error Explanation: I/O Processor detected that the bus is
not operational
Response: Error occurred on SCSI bus 2.
Response: A device was added to SCSI bus 0 of the
Failing Item: I/O Adapter and caused the bus to become not
v IOPIP13 operational. Remove the device.
v FI01107 Failing Item:
v STORIOA v SVCDOCS
v FI01140
v DEVBPLN 570B3121 570B3121
Explanation: I/O Processor detected that the bus is
not operational
Response: A device was added to SCSI bus 1 of the
I/O Adapter and caused the bus to become not
Explanation: I/O Processor detected that the bus is Response: This reference code and the 3123 reference
not operational code that occurred before it require no service action,
since SCSI bus 3 is now operational.
Response: A device was added to SCSI bus 2 of the
I/O Adapter and caused the bus to become not
operational. Remove the device. 570B3150 570B3150
Explanation: I/O Processor detected that the bus is Explanation: Disk media format bad
now operational Failing Item:
Response: This reference code and the 3121 reference v FI01105
code that occurred before it require no service action,
since SCSI bus 1 is now operational.
570B3205 570B3205
Explanation: Disk sector read error
570B3142 570B3142
Response: Disk unit data may need to be reloaded,
Explanation: I/O Processor detected that the bus is
but the disk unit does not need to be replaced.
now operational
Failing Item:
Response: This reference code and the 3122 reference
code that occurred before it require no service action, v FI01105
570B3250 570B3250
570B6070 570B6070
Explanation: Disk unit requires initialization before
use. Explanation: A permanent I/O processor failure
occurred
Response: Perform a D-IPL and work on errors found
in the log. Failing Item:
v IOP
Failing Item:
v USER
570B6071 570B6071
570B6075 570B6075
570B3401 570B3401
Explanation: I/O processor resource not available
Explanation: Device backplane problem
Failing Item:
Failing Item:
v AJDGP01
v DEVBPLN
570B6076 570B6076
570B3501 570B3501
Explanation: I/O processor card detected media error
Explanation: I/O processor Licensed Internal Code
error Failing Item:
Failing Item: v MEDIA
v AJDGP01 v AJDGP01
v IOP v FI01105
Response: No action required. Protection will be Explanation: IOP resources not available due to
automatically restarted. previous problems.
Response: Power off the system and remove all new
570B9041 570B9041 or replacement disk units. IPL the system to DST. If
you cannot perform a type A or B IPL, perform a type
Explanation: Background array parity check detected D IPL from removable media.
and corrected errors
Look for Product Activity Log entries for other IOP
Response: Call your next level of support to report reference codes and take action on them.
the problem.
Failing Item:
Failing Item:
v SVCDOCS
v AJDGP01
570B9081 570B9081
570B9050 570B9050
Explanation: I/O processor card detected device error
Explanation: Required cache data cannot be located
for a disk unit. Failing Item:
v FI01105
Failing Item:
v STORIOA
v IOPIP30
v IOP
570BBE00 570BBE00
Explanation: I/O processor detected a fault condition
570BB3E0 570BB3E0
Failing Item:
Explanation: I/O processor detected a fault condition
v AJDGP01
Failing Item:
v IOP
v IOP
v FI01104
v MA_BRDG
v MA_BRDG
570BB3E1 570BB3E1
570BFF3D 570BFF3D
Explanation: I/O processor detected a fault condition
Explanation: I/O adapter detected recoverable error
Failing Item:
Failing Item:
v IOP
v STORIOA
v MA_BRDG
v ANYBRDG
570BB410 570BB410
570BFF6D 570BFF6D
Explanation: A permanent I/O processor failure
Explanation: I/O processor detected a recoverable
occurred
system bus error
Failing Item:
Failing Item:
v STORIOA
v IOP
v ANYBUS
570BB411 570BB411
Explanation: A permanent I/O processor failure
occurred
Failing Item:
v STORIOA
570BB412 570BB412
Explanation: Tape/CD or disk bus interface error
occurred
Failing Item:
v IOPIP16
v FI01107
v FI01140
v STORIOA
v DEVTERM
570BB935 570BB935
Explanation: Unknown hardware detected
Failing Item:
v FI01101
v AJDGP01
v IOP
v MA_BRDG
v STORIOA
571A3140 571A3140
v FI01140
Explanation: Bus is operational
v DEVBPLN
Response: This reference code and the 3120 reference
code that occurred before it require no service action
571A3103 571A3103
because SCSI bus 0 is now operational.
Explanation: Interface error
Response: Error occurred on SCSI bus 3. 571A3141 571A3141
v FI01140
v DEVBPLN 571A3142 571A3142
Explanation: Bus is operational
571A3120 571A3120 Response: This reference code and the 3122 reference
Explanation: Bus is not operational code that occurred before it require no service action
because SCSI bus 2 is now operational.
Response: Adding a device to SCSI bus 0 of the I/O
Adapter caused the bus to become not operational.
Remove the device. 571A3143 571A3143
Response: NOTE: If external devices are attached Explanation: System log entry only. No service action
check EXTSCSI and DEVTERM first. required.
Failing Item:
571A4150 571A4150
v FI02112
v STORIOA Explanation: I/O adapter detected PCI bus error
v FI01106 Response: If this event appears in a serviceable event
v FI01140 view, work with the failing item list found there. If this
event does not appear in a serviceable event view, no
service action is required.
571A3401 571A3401
If you are working with one of the card types below,
Explanation: Device backplane problem the adapter has mulitple physical parts. Choose the
Failing Item: card type to identify the physical parts of the storage
adapter.
v DEVBPLN
Card type 2BE1 (feature RAID enablement card for
embedded IOA) read the following: When working the
571A3405 571A3405 FRUs from the serviceable event or the failing item list
Explanation: An error occurred during task here, the embedded storage adapter (STORIOA) has
initialization for a removable media device. This SRC is three physical parts:
logged when an error occurs and the removable media v The embedded storage adapter on the I/O
device driver cannot determine the device type or backplane.
model. v The RAID enablement card.
Response: Perform the following: v The Battery charger and carrier card.
v Check the Product Activity Log for other entries that
indicate interface problems and work those See symbolic FRU FEATCRD for the location codes of
problems. the FRUs if they are not listed in the serviceable event
v Check the device firmware level and apply the latest or if you are working the failing item list here.
PTFs.
Card type 57CB (embedded IOA with 2BCF battery
v Check for LIC logs with major code 2E00. Contact
card for embedded IOA) read the following: When
your next level of support with the information you
working the FRUs from the serviceable event or the
have gathered.
failing item list here, the embedded storage adapter
Problem determination: IPL the IOP to retry the (STORIOA) has two physical parts:
device identification process. If the error persists then v The embedded storage adapter on the I/O
contact your service provider. backplane.
Failing Item: v The Battery charger and carrier card.
v PTFSRCH
See symbolic FRU FEATCRD for the location codes of
the FRUs if they are not listed in the serviceable event
571A34FF 571A34FF or if you are working the failing item list here.
Explanation: A device on this adapter is being
formatted. Wait for the formatting to complete. Card type 57CF (embedded IOAs on DASD backplane
with 2BC2 dual battery charger and carrier card for the
Failing Item: embedded IOAs) read the following: When working
v SVCDOCS
the FRUs from the serviceable event or the failing item Card type 57CF (embedded IOAs on DASD backplane
list here, the embedded storage adapters (STORIOA) with 2BC2 dual battery charger and carrier card for the
have two physical parts: embedded IOAs) read the following: When working
v The embedded storage adapter on the DASD the FRUs from the serviceable event or the failing item
backplane. list here, the embedded storage adapters (STORIOA)
have two physical parts:
v The dual battery charger and carrier card. To
determine which battery is connected to which v The embedded storage adapter on the DASD
embedded IOA use the bus number of the IOA with backplane.
symbolic FRU CACHBAT. v The dual battery charger and carrier card. To
determine which battery is connected to which
See symbolic FRU FEATCRD for the location code of embedded IOA use the bus number of the IOA with
the dual battery charger and carrier card if it is not symbolic FRU CACHBAT.
listed in the serviceable event or if you are working the
failing item list here. See symbolic FRU FEATCRD for the location code of
the dual battery charger and carrier card if it is not
Failing Item:
listed in the serviceable event or if you are working the
v BACKPLN failing item list here.
v STORIOA
Failing Item:
v BACKPLN
571A4160 571A4160
v STORIOA
Explanation: I/O adapter detected and recovered a
PCI bus error
571A8008 571A8008
Response: If this event appears in a serviceable event
Explanation: A permanent cache battery pack failure
view, work with the failing item list found there. If this
occurred
event does not appear in a serviceable event view, no
service action is required. Response: NOTE: Under a certain configuration, this
SRC may not represent an error that requires a service
If you are working with one of the card types below,
action. Depending on the configuration of the system,
the adapter has mulitple physical parts. Choose the
the Storage IOA may have been altered and/or the
card type to identify the physical parts of the storage
Storage IOA Cache may have been disabled to allow
adapter.
attachment of OEM Storage that emulates a Load
Card type 2BE1 (feature RAID enablement card for Source drive. If this is the case, this error will be posted
embedded IOA) read the following: When working the each time the IOA is IPLed and it can be ignored.
FRUs from the serviceable event or the failing item list
Failing Item:
here, the embedded storage adapter (STORIOA) has
three physical parts: v CACHBAT
v The embedded storage adapter on the I/O v STORIOA
backplane.
v The RAID enablement card. 571A8009 571A8009
v The Battery charger and carrier card. Explanation: Impending cache battery pack failure
See symbolic FRU FEATCRD for the location codes of Failing Item:
the FRUs if they are not listed in the serviceable event v CACHBAT
or if you are working the failing item list here.
571A8100 571A8100
Card type 57CB (embedded IOA with 2BCF battery
card for embedded IOA) read the following: When Explanation: Licensed Internal Code error
working the FRUs from the serviceable event or the
Failing Item:
failing item list here, the embedded storage adapter
(STORIOA) has two physical parts: v PTFSRCH
v The embedded storage adapter on the I/O v STORIOA
backplane.
v The Battery charger and carrier card. 571A8130 571A8130
Explanation: IOA detected recoverable device bus
See symbolic FRU FEATCRD for the location codes of
error
the FRUs if they are not listed in the serviceable event
or if you are working the failing item list here. Response: An error occurred on SCSI bus 0. No action
v SVCDOCS
571A9002 571A9002
Explanation: Device error
571A8300 571A8300
Response:
Explanation: IOA hardware error or PCI bus error
Failing Item:
Failing Item:
v IOPIP16
v STORIOA
v FI01105
v ANYBRDG
v STORIOA
v PTFSRCH
v FI01140
v BACKPLN
571A8301 571A8301
v FI01106
Explanation: Not valid condition in Licensed Internal
Code
571A9008 571A9008
Failing Item:
Explanation: I/O card does not support functions
v PTFSRCH
expected by devices
v STORIOA
Response:
571A8400 571A8400
571A9010 571A9010
Explanation: Licensed Internal Code error
Explanation: Cache data associated with attached
Failing Item: devices cannot be found
v PTFSRCH
Response:
Failing Item:
571A8404 571A8404
v IOPIP31
Explanation: System log entry only. No service action
required.
571A9011 571A9011
571A9020 571A9020
571A9001 571A9001
Explanation: Array not functional due to present
Explanation: Device configuration error
hardware configuration.
Response:
Response:
Failing Item:
Failing Item:
v IOPIP33
v IOPIP20
571A9040 571A9040
571A9053 571A9053
Explanation: Array protection temporarily suspended
Explanation: IOA resources not available due to
Response: No action required. Protection will be previous problems
automatically restarted.
Response: Take action on other reference codes which
have surfaced.
571A9041 571A9041
If you cannot get to SST or DST, and cannot perform a
Explanation: Background array parity check detected type A or B IPL, perform a type D IPL from removable
and corrected errors media. Look for Product Activity Log entries for other
reference codes and take action on them.
Response: Call your next level of support to report
the problem. Failing Item:
Failing Item: v SVCDOCS
v PTFSRCH
571A9054 571A9054
571A9042 571A9042 Explanation: IOA resources not available due to
previous problems
Explanation: An array parity error has been detected
and corrected Response: Power off the system and remove all new
or replacement disk units. IPL the system to DST. If
Response: Call your next level of support to report
you cannot perform a type A or B IPL, perform a type
the problem.
D IPL from removable media.
Failing Item:
Look for Product Activity Log entries for other
v NEXTLVL reference codes and take action on them.
Failing Item:
571A9050 571A9050
v SVCDOCS
Explanation: Required cache data cannot be located
for a disk unit.
571A9071 571A9071
Response:
Explanation: Link from IOA to auxiliary cache IOA
Failing Item: went operational
v IOPIP30 Response: No service action required.
Response:
571A9903 571A9903
Failing Item:
Explanation: Tape device information was logged.
v IOPIP16
Informational event, no service required.
v FI01105
v STORIOA
571AC000 571AC000
v FI01140
Explanation: System log entry only. No service action
v BACKPLN
required.
v FI01106
Response: No action is required. This reference code
is logged for information only.
571A9090 571A9090
Explanation: Disk unit has been modified after the 571AC100 571AC100
last known status.
Explanation: System log entry only. No service action
Response: Re-IPL the system. If any reference codes required.
are surfaced, use the new reference code to resolve the
problem. Response: No action is required. This reference code
is logged for information only.
If you cannot resolve the problem, contact your next
level of support.
571AC402 571AC402
Failing Item:
Explanation: Licensed Internal Code error
v SVCDOCS
Response: Ask your next level of support for
assistance.
571A9091 571A9091
Failing Item:
Explanation: Incorrect hardware configuration change
detected v PTFSRCH
571AFF6D 571AFF6D
Explanation: Recoverable system bus error
Failing Item:
v STORIOA
v ANYBRDG
v PTFSRCH
v STORIOA
571B3140 571B3140
v FI01140
Explanation: Bus is operational
v DEVBPLN
Response: This reference code and the 3120 reference
code that occurred before it require no service action
571B3103 571B3103
because SCSI bus 0 is now operational.
Explanation: Interface error
Response: Error occurred on SCSI bus 3. 571B3141 571B3141
v FI01140
v DEVBPLN 571B3142 571B3142
Explanation: Bus is operational
571B3120 571B3120 Response: This reference code and the 3122 reference
Explanation: Bus is not operational code that occurred before it require no service action
because SCSI bus 2 is now operational.
Response: Adding a device to SCSI bus 0 of the I/O
Adapter caused the bus to become not operational.
Remove the device. 571B3143 571B3143
Response: NOTE: If external devices are attached Explanation: System log entry only. No service action
check EXTSCSI and DEVTERM first. required.
Failing Item:
571B4150 571B4150
v FI02112
v STORIOA Explanation: I/O adapter detected PCI bus error
v FI01106 Response: If this event appears in a serviceable event
v FI01140 view, work with the failing item list found there. If this
event does not appear in a serviceable event view, no
service action is required.
571B3401 571B3401
If you are working with one of the card types below,
Explanation: Device backplane problem the adapter has mulitple physical parts. Choose the
Failing Item: card type to identify the physical parts of the storage
adapter.
v DEVBPLN
Card type 2BE1 (feature RAID enablement card for
embedded IOA) read the following: When working the
571B3405 571B3405 FRUs from the serviceable event or the failing item list
Explanation: An error occurred during task here, the embedded storage adapter (STORIOA) has
initialization for a removable media device. This SRC is three physical parts:
logged when an error occurs and the removable media v The embedded storage adapter on the I/O
device driver cannot determine the device type or backplane.
model. v The RAID enablement card.
Response: Perform the following: v The Battery charger and carrier card.
v Check the Product Activity Log for other entries that
indicate interface problems and work those See symbolic FRU FEATCRD for the location codes of
problems. the FRUs if they are not listed in the serviceable event
v Check the device firmware level and apply the latest or if you are working the failing item list here.
PTFs.
Card type 57CB (embedded IOA with 2BCF battery
v Check for LIC logs with major code 2E00. Contact
card for embedded IOA) read the following: When
your next level of support with the information you
working the FRUs from the serviceable event or the
have gathered.
failing item list here, the embedded storage adapter
Problem determination: IPL the IOP to retry the (STORIOA) has two physical parts:
device identification process. If the error persists then v The embedded storage adapter on the I/O
contact your service provider. backplane.
Failing Item: v The Battery charger and carrier card.
v PTFSRCH
See symbolic FRU FEATCRD for the location codes of
the FRUs if they are not listed in the serviceable event
571B34FF 571B34FF or if you are working the failing item list here.
Explanation: A device on this adapter is being
formatted. Wait for the formatting to complete. Card type 57CF (embedded IOAs on DASD backplane
with 2BC2 dual battery charger and carrier card for the
Failing Item: embedded IOAs) read the following: When working
v SVCDOCS
the FRUs from the serviceable event or the failing item Card type 57CF (embedded IOAs on DASD backplane
list here, the embedded storage adapters (STORIOA) with 2BC2 dual battery charger and carrier card for the
have two physical parts: embedded IOAs) read the following: When working
v The embedded storage adapter on the DASD the FRUs from the serviceable event or the failing item
backplane. list here, the embedded storage adapters (STORIOA)
have two physical parts:
v The dual battery charger and carrier card. To
determine which battery is connected to which v The embedded storage adapter on the DASD
embedded IOA use the bus number of the IOA with backplane.
symbolic FRU CACHBAT. v The dual battery charger and carrier card. To
determine which battery is connected to which
See symbolic FRU FEATCRD for the location code of embedded IOA use the bus number of the IOA with
the dual battery charger and carrier card if it is not symbolic FRU CACHBAT.
listed in the serviceable event or if you are working the
failing item list here. See symbolic FRU FEATCRD for the location code of
the dual battery charger and carrier card if it is not
Failing Item:
listed in the serviceable event or if you are working the
v BACKPLN failing item list here.
v STORIOA
Failing Item:
v BACKPLN
571B4160 571B4160
v STORIOA
Explanation: I/O adapter detected and recovered a
PCI bus error
571B8008 571B8008
Response: If this event appears in a serviceable event
Explanation: A permanent cache battery pack failure
view, work with the failing item list found there. If this
occurred
event does not appear in a serviceable event view, no
service action is required. Response: NOTE: Under a certain configuration, this
SRC may not represent an error that requires a service
If you are working with one of the card types below,
action. Depending on the configuration of the system,
the adapter has mulitple physical parts. Choose the
the Storage IOA may have been altered and/or the
card type to identify the physical parts of the storage
Storage IOA Cache may have been disabled to allow
adapter.
attachment of OEM Storage that emulates a Load
Card type 2BE1 (feature RAID enablement card for Source drive. If this is the case, this error will be posted
embedded IOA) read the following: When working the each time the IOA is IPLed and it can be ignored.
FRUs from the serviceable event or the failing item list
Failing Item:
here, the embedded storage adapter (STORIOA) has
three physical parts: v CACHBAT
v The embedded storage adapter on the I/O v STORIOA
backplane.
v The RAID enablement card. 571B8009 571B8009
v The Battery charger and carrier card. Explanation: Impending cache battery pack failure
See symbolic FRU FEATCRD for the location codes of Failing Item:
the FRUs if they are not listed in the serviceable event v CACHBAT
or if you are working the failing item list here.
571B8100 571B8100
Card type 57CB (embedded IOA with 2BCF battery
card for embedded IOA) read the following: When Explanation: Licensed Internal Code error
working the FRUs from the serviceable event or the
Failing Item:
failing item list here, the embedded storage adapter
(STORIOA) has two physical parts: v PTFSRCH
v The embedded storage adapter on the I/O v STORIOA
backplane.
v The Battery charger and carrier card. 571B8130 571B8130
Explanation: IOA detected recoverable device bus
See symbolic FRU FEATCRD for the location codes of
error
the FRUs if they are not listed in the serviceable event
or if you are working the failing item list here. Response: An error occurred on SCSI bus 0. No action
v SVCDOCS
571B9002 571B9002
Explanation: Device error
571B8300 571B8300
Response:
Explanation: IOA hardware error or PCI bus error
Failing Item:
Failing Item:
v IOPIP16
v STORIOA
v FI01105
v ANYBRDG
v STORIOA
v PTFSRCH
v FI01140
v BACKPLN
571B8301 571B8301
v FI01106
Explanation: Not valid condition in Licensed Internal
Code
571B9008 571B9008
Failing Item:
Explanation: I/O card does not support functions
v PTFSRCH
expected by devices
v STORIOA
Response:
571B8400 571B8400
571B9010 571B9010
Explanation: Licensed Internal Code error
Explanation: Cache data associated with attached
Failing Item: devices cannot be found
v PTFSRCH
Response:
Failing Item:
571B8404 571B8404
v IOPIP31
Explanation: System log entry only. No service action
required.
571B9011 571B9011
571B9020 571B9020
571B9001 571B9001
Explanation: Array not functional due to present
Explanation: Device configuration error
hardware configuration.
Response:
Response:
Failing Item:
Failing Item:
v IOPIP33
v IOPIP20
571B9040 571B9040
571B9053 571B9053
Explanation: Array protection temporarily suspended
Explanation: IOA resources not available due to
Response: No action required. Protection will be previous problems
automatically restarted.
Response: Take action on other reference codes which
have surfaced.
571B9041 571B9041
If you cannot get to SST or DST, and cannot perform a
Explanation: Background array parity check detected type A or B IPL, perform a type D IPL from removable
and corrected errors media. Look for Product Activity Log entries for other
reference codes and take action on them.
Response: Call your next level of support to report
the problem. Failing Item:
Failing Item: v SVCDOCS
v PTFSRCH
571B9054 571B9054
571B9042 571B9042 Explanation: IOA resources not available due to
previous problems
Explanation: An array parity error has been detected
and corrected Response: Power off the system and remove all new
or replacement disk units. IPL the system to DST. If
Response: Call your next level of support to report
you cannot perform a type A or B IPL, perform a type
the problem.
D IPL from removable media.
Failing Item:
Look for Product Activity Log entries for other
v NEXTLVL reference codes and take action on them.
Failing Item:
571B9050 571B9050
v SVCDOCS
Explanation: Required cache data cannot be located
for a disk unit.
571B9071 571B9071
Response:
Explanation: Link from IOA to auxiliary cache IOA
Failing Item: went operational
v IOPIP30 Response: No service action required.
Response:
571B9903 571B9903
Failing Item:
Explanation: Tape device information was logged.
v IOPIP16
Informational event, no service required.
v FI01105
v STORIOA
571BC000 571BC000
v FI01140
Explanation: System log entry only. No service action
v BACKPLN
required.
v FI01106
Response: No action is required. This reference code
is logged for information only.
571B9090 571B9090
Explanation: Disk unit has been modified after the 571BC100 571BC100
last known status.
Explanation: System log entry only. No service action
Response: Re-IPL the system. If any reference codes required.
are surfaced, use the new reference code to resolve the
problem. Response: No action is required. This reference code
is logged for information only.
If you cannot resolve the problem, contact your next
level of support.
571BC402 571BC402
Failing Item:
Explanation: Licensed Internal Code error
v SVCDOCS
Response: Ask your next level of support for
assistance.
571B9091 571B9091
Failing Item:
Explanation: Incorrect hardware configuration change
detected v PTFSRCH
571BFF6D 571BFF6D
Explanation: Recoverable system bus error
Failing Item:
v STORIOA
v ANYBRDG
v PTFSRCH
v STORIOA
571E3140 571E3140
v FI01140
Explanation: Bus is operational
v DEVBPLN
Response: This reference code and the 3120 reference
code that occurred before it require no service action
571E3103 571E3103
because SCSI bus 0 is now operational.
Explanation: Interface error
Response: Error occurred on SCSI bus 3. 571E3141 571E3141
v FI01140
v DEVBPLN 571E3142 571E3142
Explanation: Bus is operational
571E3120 571E3120 Response: This reference code and the 3122 reference
Explanation: Bus is not operational code that occurred before it require no service action
because SCSI bus 2 is now operational.
Response: Adding a device to SCSI bus 0 of the I/O
Adapter caused the bus to become not operational.
Remove the device. 571E3143 571E3143
Response: NOTE: If external devices are attached Explanation: System log entry only. No service action
check EXTSCSI and DEVTERM first. required.
Failing Item:
571E4150 571E4150
v FI02112
v STORIOA Explanation: I/O adapter detected PCI bus error
v FI01106 Response: If this event appears in a serviceable event
v FI01140 view, work with the failing item list found there. If this
event does not appear in a serviceable event view, no
service action is required.
571E3401 571E3401
If you are working with one of the card types below,
Explanation: Device backplane problem the adapter has mulitple physical parts. Choose the
Failing Item: card type to identify the physical parts of the storage
adapter.
v DEVBPLN
Card type 2BE1 (feature RAID enablement card for
embedded IOA) read the following: When working the
571E3405 571E3405 FRUs from the serviceable event or the failing item list
Explanation: An error occurred during task here, the embedded storage adapter (STORIOA) has
initialization for a removable media device. This SRC is three physical parts:
logged when an error occurs and the removable media v The embedded storage adapter on the I/O
device driver cannot determine the device type or backplane.
model. v The RAID enablement card.
Response: Perform the following: v The Battery charger and carrier card.
v Check the Product Activity Log for other entries that
indicate interface problems and work those See symbolic FRU FEATCRD for the location codes of
problems. the FRUs if they are not listed in the serviceable event
v Check the device firmware level and apply the latest or if you are working the failing item list here.
PTFs.
Card type 57CB (embedded IOA with 2BCF battery
v Check for LIC logs with major code 2E00. Contact
card for embedded IOA) read the following: When
your next level of support with the information you
working the FRUs from the serviceable event or the
have gathered.
failing item list here, the embedded storage adapter
Problem determination: IPL the IOP to retry the (STORIOA) has two physical parts:
device identification process. If the error persists then v The embedded storage adapter on the I/O
contact your service provider. backplane.
Failing Item: v The Battery charger and carrier card.
v PTFSRCH
See symbolic FRU FEATCRD for the location codes of
the FRUs if they are not listed in the serviceable event
571E34FF 571E34FF or if you are working the failing item list here.
Explanation: A device on this adapter is being
formatted. Wait for the formatting to complete. Card type 57CF (embedded IOAs on DASD backplane
with 2BC2 dual battery charger and carrier card for the
Failing Item: embedded IOAs) read the following: When working
v SVCDOCS
the FRUs from the serviceable event or the failing item Card type 57CF (embedded IOAs on DASD backplane
list here, the embedded storage adapters (STORIOA) with 2BC2 dual battery charger and carrier card for the
have two physical parts: embedded IOAs) read the following: When working
v The embedded storage adapter on the DASD the FRUs from the serviceable event or the failing item
backplane. list here, the embedded storage adapters (STORIOA)
have two physical parts:
v The dual battery charger and carrier card. To
determine which battery is connected to which v The embedded storage adapter on the DASD
embedded IOA use the bus number of the IOA with backplane.
symbolic FRU CACHBAT. v The dual battery charger and carrier card. To
determine which battery is connected to which
See symbolic FRU FEATCRD for the location code of embedded IOA use the bus number of the IOA with
the dual battery charger and carrier card if it is not symbolic FRU CACHBAT.
listed in the serviceable event or if you are working the
failing item list here. See symbolic FRU FEATCRD for the location code of
the dual battery charger and carrier card if it is not
Failing Item:
listed in the serviceable event or if you are working the
v BACKPLN failing item list here.
v STORIOA
Failing Item:
v BACKPLN
571E4160 571E4160
v STORIOA
Explanation: I/O adapter detected and recovered a
PCI bus error
571E8008 571E8008
Response: If this event appears in a serviceable event
Explanation: A permanent cache battery pack failure
view, work with the failing item list found there. If this
occurred
event does not appear in a serviceable event view, no
service action is required. Response: NOTE: Under a certain configuration, this
SRC may not represent an error that requires a service
If you are working with one of the card types below,
action. Depending on the configuration of the system,
the adapter has mulitple physical parts. Choose the
the Storage IOA may have been altered and/or the
card type to identify the physical parts of the storage
Storage IOA Cache may have been disabled to allow
adapter.
attachment of OEM Storage that emulates a Load
Card type 2BE1 (feature RAID enablement card for Source drive. If this is the case, this error will be posted
embedded IOA) read the following: When working the each time the IOA is IPLed and it can be ignored.
FRUs from the serviceable event or the failing item list
Failing Item:
here, the embedded storage adapter (STORIOA) has
three physical parts: v CACHBAT
v The embedded storage adapter on the I/O v STORIOA
backplane.
v The RAID enablement card. 571E8009 571E8009
v The Battery charger and carrier card. Explanation: Impending cache battery pack failure
See symbolic FRU FEATCRD for the location codes of Failing Item:
the FRUs if they are not listed in the serviceable event v CACHBAT
or if you are working the failing item list here.
571E8100 571E8100
Card type 57CB (embedded IOA with 2BCF battery
card for embedded IOA) read the following: When Explanation: Licensed Internal Code error
working the FRUs from the serviceable event or the
Failing Item:
failing item list here, the embedded storage adapter
(STORIOA) has two physical parts: v PTFSRCH
v The embedded storage adapter on the I/O v STORIOA
backplane.
v The Battery charger and carrier card. 571E8130 571E8130
Explanation: IOA detected recoverable device bus
See symbolic FRU FEATCRD for the location codes of
error
the FRUs if they are not listed in the serviceable event
or if you are working the failing item list here. Response: An error occurred on SCSI bus 0. No action
v SVCDOCS
571E9002 571E9002
Explanation: Device error
571E8300 571E8300
Response:
Explanation: IOA hardware error or PCI bus error
Failing Item:
Failing Item:
v IOPIP16
v STORIOA
v FI01105
v ANYBRDG
v STORIOA
v PTFSRCH
v FI01140
v BACKPLN
571E8301 571E8301
v FI01106
Explanation: Not valid condition in Licensed Internal
Code
571E9008 571E9008
Failing Item:
Explanation: I/O card does not support functions
v PTFSRCH
expected by devices
v STORIOA
Response:
571E8400 571E8400
571E9010 571E9010
Explanation: Licensed Internal Code error
Explanation: Cache data associated with attached
Failing Item: devices cannot be found
v PTFSRCH
Response:
Failing Item:
571E8404 571E8404
v IOPIP31
Explanation: System log entry only. No service action
required.
571E9011 571E9011
571E9020 571E9020
571E9001 571E9001
Explanation: Array not functional due to present
Explanation: Device configuration error
hardware configuration.
Response:
Response:
Failing Item:
Failing Item:
v IOPIP33
v IOPIP20
571E9040 571E9040
571E9053 571E9053
Explanation: Array protection temporarily suspended
Explanation: IOA resources not available due to
Response: No action required. Protection will be previous problems
automatically restarted.
Response: Take action on other reference codes which
have surfaced.
571E9041 571E9041
If you cannot get to SST or DST, and cannot perform a
Explanation: Background array parity check detected type A or B IPL, perform a type D IPL from removable
and corrected errors media. Look for Product Activity Log entries for other
reference codes and take action on them.
Response: Call your next level of support to report
the problem. Failing Item:
Failing Item: v SVCDOCS
v PTFSRCH
571E9054 571E9054
571E9042 571E9042 Explanation: IOA resources not available due to
previous problems
Explanation: An array parity error has been detected
and corrected Response: Power off the system and remove all new
or replacement disk units. IPL the system to DST. If
Response: Call your next level of support to report
you cannot perform a type A or B IPL, perform a type
the problem.
D IPL from removable media.
Failing Item:
Look for Product Activity Log entries for other
v NEXTLVL reference codes and take action on them.
Failing Item:
571E9050 571E9050
v SVCDOCS
Explanation: Required cache data cannot be located
for a disk unit.
571E9071 571E9071
Response:
Explanation: Link from IOA to auxiliary cache IOA
Failing Item: went operational
v IOPIP30 Response: No service action required.
Response:
571E9903 571E9903
Failing Item:
Explanation: Tape device information was logged.
v IOPIP16
Informational event, no service required.
v FI01105
v STORIOA
571EC000 571EC000
v FI01140
Explanation: System log entry only. No service action
v BACKPLN
required.
v FI01106
Response: No action is required. This reference code
is logged for information only.
571E9090 571E9090
Explanation: Disk unit has been modified after the 571EC100 571EC100
last known status.
Explanation: System log entry only. No service action
Response: Re-IPL the system. If any reference codes required.
are surfaced, use the new reference code to resolve the
problem. Response: No action is required. This reference code
is logged for information only.
If you cannot resolve the problem, contact your next
level of support.
571EC402 571EC402
Failing Item:
Explanation: Licensed Internal Code error
v SVCDOCS
Response: Ask your next level of support for
assistance.
571E9091 571E9091
Failing Item:
Explanation: Incorrect hardware configuration change
detected v PTFSRCH
571EFF6D 571EFF6D
Explanation: Recoverable system bus error
Failing Item:
v STORIOA
v ANYBRDG
v PTFSRCH
v STORIOA
571F3140 571F3140
v FI01140
Explanation: Bus is operational
v DEVBPLN
Response: This reference code and the 3120 reference
code that occurred before it require no service action
571F3103 571F3103
because SCSI bus 0 is now operational.
Explanation: Interface error
Response: Error occurred on SCSI bus 3. 571F3141 571F3141
v FI01140
v DEVBPLN 571F3142 571F3142
Explanation: Bus is operational
571F3120 571F3120 Response: This reference code and the 3122 reference
Explanation: Bus is not operational code that occurred before it require no service action
because SCSI bus 2 is now operational.
Response: Adding a device to SCSI bus 0 of the I/O
Adapter caused the bus to become not operational.
Remove the device. 571F3143 571F3143
Response: NOTE: If external devices are attached Explanation: System log entry only. No service action
check EXTSCSI and DEVTERM first. required.
Failing Item:
571F4150 571F4150
v FI02112
v STORIOA Explanation: I/O adapter detected PCI bus error
v FI01106 Response: If this event appears in a serviceable event
v FI01140 view, work with the failing item list found there. If this
event does not appear in a serviceable event view, no
service action is required.
571F3401 571F3401
If you are working with one of the card types below,
Explanation: Device backplane problem the adapter has mulitple physical parts. Choose the
Failing Item: card type to identify the physical parts of the storage
adapter.
v DEVBPLN
Card type 2BE1 (feature RAID enablement card for
embedded IOA) read the following: When working the
571F3405 571F3405 FRUs from the serviceable event or the failing item list
Explanation: An error occurred during task here, the embedded storage adapter (STORIOA) has
initialization for a removable media device. This SRC is three physical parts:
logged when an error occurs and the removable media v The embedded storage adapter on the I/O
device driver cannot determine the device type or backplane.
model. v The RAID enablement card.
Response: Perform the following: v The Battery charger and carrier card.
v Check the Product Activity Log for other entries that
indicate interface problems and work those See symbolic FRU FEATCRD for the location codes of
problems. the FRUs if they are not listed in the serviceable event
v Check the device firmware level and apply the latest or if you are working the failing item list here.
PTFs.
Card type 57CB (embedded IOA with 2BCF battery
v Check for LIC logs with major code 2E00. Contact
card for embedded IOA) read the following: When
your next level of support with the information you
working the FRUs from the serviceable event or the
have gathered.
failing item list here, the embedded storage adapter
Problem determination: IPL the IOP to retry the (STORIOA) has two physical parts:
device identification process. If the error persists then v The embedded storage adapter on the I/O
contact your service provider. backplane.
Failing Item: v The Battery charger and carrier card.
v PTFSRCH
See symbolic FRU FEATCRD for the location codes of
the FRUs if they are not listed in the serviceable event
571F34FF 571F34FF or if you are working the failing item list here.
Explanation: A device on this adapter is being
formatted. Wait for the formatting to complete. Card type 57CF (embedded IOAs on DASD backplane
with 2BC2 dual battery charger and carrier card for the
Failing Item: embedded IOAs) read the following: When working
v SVCDOCS
the FRUs from the serviceable event or the failing item Card type 57CF (embedded IOAs on DASD backplane
list here, the embedded storage adapters (STORIOA) with 2BC2 dual battery charger and carrier card for the
have two physical parts: embedded IOAs) read the following: When working
v The embedded storage adapter on the DASD the FRUs from the serviceable event or the failing item
backplane. list here, the embedded storage adapters (STORIOA)
have two physical parts:
v The dual battery charger and carrier card. To
determine which battery is connected to which v The embedded storage adapter on the DASD
embedded IOA use the bus number of the IOA with backplane.
symbolic FRU CACHBAT. v The dual battery charger and carrier card. To
determine which battery is connected to which
See symbolic FRU FEATCRD for the location code of embedded IOA use the bus number of the IOA with
the dual battery charger and carrier card if it is not symbolic FRU CACHBAT.
listed in the serviceable event or if you are working the
failing item list here. See symbolic FRU FEATCRD for the location code of
the dual battery charger and carrier card if it is not
Failing Item:
listed in the serviceable event or if you are working the
v BACKPLN failing item list here.
v STORIOA
Failing Item:
v BACKPLN
571F4160 571F4160
v STORIOA
Explanation: I/O adapter detected and recovered a
PCI bus error
571F8008 571F8008
Response: If this event appears in a serviceable event
Explanation: A permanent cache battery pack failure
view, work with the failing item list found there. If this
occurred
event does not appear in a serviceable event view, no
service action is required. Response: NOTE: Under a certain configuration, this
SRC may not represent an error that requires a service
If you are working with one of the card types below,
action. Depending on the configuration of the system,
the adapter has mulitple physical parts. Choose the
the Storage IOA may have been altered and/or the
card type to identify the physical parts of the storage
Storage IOA Cache may have been disabled to allow
adapter.
attachment of OEM Storage that emulates a Load
Card type 2BE1 (feature RAID enablement card for Source drive. If this is the case, this error will be posted
embedded IOA) read the following: When working the each time the IOA is IPLed and it can be ignored.
FRUs from the serviceable event or the failing item list
Failing Item:
here, the embedded storage adapter (STORIOA) has
three physical parts: v CACHBAT
v The embedded storage adapter on the I/O v STORIOA
backplane.
v The RAID enablement card. 571F8009 571F8009
v The Battery charger and carrier card. Explanation: Impending cache battery pack failure
See symbolic FRU FEATCRD for the location codes of Failing Item:
the FRUs if they are not listed in the serviceable event v CACHBAT
or if you are working the failing item list here.
571F8100 571F8100
Card type 57CB (embedded IOA with 2BCF battery
card for embedded IOA) read the following: When Explanation: Licensed Internal Code error
working the FRUs from the serviceable event or the
Failing Item:
failing item list here, the embedded storage adapter
(STORIOA) has two physical parts: v PTFSRCH
v The embedded storage adapter on the I/O v STORIOA
backplane.
v The Battery charger and carrier card. 571F8130 571F8130
Explanation: IOA detected recoverable device bus
See symbolic FRU FEATCRD for the location codes of
error
the FRUs if they are not listed in the serviceable event
or if you are working the failing item list here. Response: An error occurred on SCSI bus 0. No action
v SVCDOCS
571F9002 571F9002
Explanation: Device error
571F8300 571F8300
Response:
Explanation: IOA hardware error or PCI bus error
Failing Item:
Failing Item:
v IOPIP16
v STORIOA
v FI01105
v ANYBRDG
v STORIOA
v PTFSRCH
v FI01140
v BACKPLN
571F8301 571F8301
v FI01106
Explanation: Not valid condition in Licensed Internal
Code
571F9008 571F9008
Failing Item:
Explanation: I/O card does not support functions
v PTFSRCH
expected by devices
v STORIOA
Response:
571F8400 571F8400
571F9010 571F9010
Explanation: Licensed Internal Code error
Explanation: Cache data associated with attached
Failing Item: devices cannot be found
v PTFSRCH
Response:
Failing Item:
571F8404 571F8404
v IOPIP31
Explanation: System log entry only. No service action
required.
571F9011 571F9011
571F9020 571F9020
571F9001 571F9001
Explanation: Array not functional due to present
Explanation: Device configuration error
hardware configuration.
Response:
Response:
Failing Item:
Failing Item:
v IOPIP33
v IOPIP20
571F9040 571F9040
571F9053 571F9053
Explanation: Array protection temporarily suspended
Explanation: IOA resources not available due to
Response: No action required. Protection will be previous problems
automatically restarted.
Response: Take action on other reference codes which
have surfaced.
571F9041 571F9041
If you cannot get to SST or DST, and cannot perform a
Explanation: Background array parity check detected type A or B IPL, perform a type D IPL from removable
and corrected errors media. Look for Product Activity Log entries for other
reference codes and take action on them.
Response: Call your next level of support to report
the problem. Failing Item:
Failing Item: v SVCDOCS
v PTFSRCH
571F9054 571F9054
571F9042 571F9042 Explanation: IOA resources not available due to
previous problems
Explanation: An array parity error has been detected
and corrected Response: Power off the system and remove all new
or replacement disk units. IPL the system to DST. If
Response: Call your next level of support to report
you cannot perform a type A or B IPL, perform a type
the problem.
D IPL from removable media.
Failing Item:
Look for Product Activity Log entries for other
v NEXTLVL reference codes and take action on them.
Failing Item:
571F9050 571F9050
v SVCDOCS
Explanation: Required cache data cannot be located
for a disk unit.
571F9071 571F9071
Response:
Explanation: Link from IOA to auxiliary cache IOA
Failing Item: went operational
v IOPIP30 Response: No service action required.
Response:
571F9903 571F9903
Failing Item:
Explanation: Tape device information was logged.
v IOPIP16
Informational event, no service required.
v FI01105
v STORIOA
571FC000 571FC000
v FI01140
Explanation: System log entry only. No service action
v BACKPLN
required.
v FI01106
Response: No action is required. This reference code
is logged for information only.
571F9090 571F9090
Explanation: Disk unit has been modified after the 571FC100 571FC100
last known status.
Explanation: System log entry only. No service action
Response: Re-IPL the system. If any reference codes required.
are surfaced, use the new reference code to resolve the
problem. Response: No action is required. This reference code
is logged for information only.
If you cannot resolve the problem, contact your next
level of support.
571FC402 571FC402
Failing Item:
Explanation: Licensed Internal Code error
v SVCDOCS
Response: Ask your next level of support for
assistance.
571F9091 571F9091
Failing Item:
Explanation: Incorrect hardware configuration change
detected v PTFSRCH
571FFF6D 571FFF6D
Explanation: Recoverable system bus error
Failing Item:
v STORIOA
v ANYBRDG
v PTFSRCH
v The embedded storage adapter on the I/O Card type 2BE1 (feature RAID enablement card for
backplane. embedded IOA) read the following: When working the
v The RAID enablement card. FRUs from the serviceable event or the failing item list
here, the embedded storage adapter (STORIOA) has
v The Battery charger and carrier card. three physical parts:
v The embedded storage adapter on the I/O
See symbolic FRU FEATCRD for the location codes of
backplane.
the FRUs if they are not listed in the serviceable event
or if you are working the failing item list here. v The RAID enablement card.
v The Battery charger and carrier card.
Card type 57CB (embedded IOA with 2BCF battery
card for embedded IOA) read the following: When See symbolic FRU FEATCRD for the location codes of
working the FRUs from the serviceable event or the the FRUs if they are not listed in the serviceable event
failing item list here, the embedded storage adapter or if you are working the failing item list here.
(STORIOA) has two physical parts:
Card type 57CB (embedded IOA with 2BCF battery v The RAID enablement card.
card for embedded IOA) read the following: When v The Battery charger and carrier card.
working the FRUs from the serviceable event or the
failing item list here, the embedded storage adapter See symbolic FRU FEATCRD for the location codes of
(STORIOA) has two physical parts: the FRUs if they are not listed in the serviceable event
v The embedded storage adapter on the I/O or if you are working the failing item list here.
backplane.
v The Battery charger and carrier card. Card type 57CB (embedded IOA with 2BCF battery
card) read the following: When working the FRUs from
See symbolic FRU FEATCRD for the location codes of the serviceable event or the failing item list here, the
the FRUs if they are not listed in the serviceable event embedded storage adapter (STORIOA) has two
or if you are working the failing item list here. physical parts:
v The embedded storage adapter on the I/O
Card type 57CF (embedded IOAs on DASD backplane backplane.
with 2BC2 dual battery charger and carrier card for the v The Battery charger and carrier card.
embedded IOAs) read the following: When working
the FRUs from the serviceable event or the failing item See symbolic FRU FEATCRD for the location codes of
list here, the embedded storage adapters (STORIOA) the FRUs if they are not listed in the serviceable event
have two physical parts: or if you are working the failing item list here.
v The embedded storage adapter on the DASD
backplane. Card type 57CF (embedded IOAs on DASD backplane
v The dual battery charger and carrier card. To with 2BC2 dual battery charger and carrier card) read
determine which battery is connected to which the following: When working the FRUs from the
embedded IOA use the bus number of the IOA with serviceable event or the failing item list here, the
symbolic FRU CACHBAT. embedded storage adapters (STORIOA) have two
physical parts:
See symbolic FRU FEATCRD for the location code of v The embedded storage adapter on the DASD
the dual battery charger and carrier card if it is not backplane.
listed in the serviceable event or if you are working the v The dual battery charger and carrier card. To
failing item list here. determine which battery is connected to which
Failing Item: embedded IOA use the bus number of the IOA with
symbolic FRU CACHBAT.
v BACKPLN
v STORIOA See symbolic FRU FEATCRD for the location code of
the dual battery charger and carrier card if it is not
572A8008 572A8008 listed in the serviceable event or if you are working the
failing item list here.
Explanation: A permanent cache battery pack failure
occurred Failing Item:
v CACHBAT
Response: Under a certain configuration, this SRC
may not represent an error that requires a service v STORIOA
action. Depending on the configuration of the system, v FEATCRD
the Storage IOA may have been altered and/or the
Storage IOA Cache may have been disabled to allow
attachment of OEM Storage that emulates a Load 572A8009 572A8009
Source drive. If this is the case, this error will be posted Explanation: Impending cache battery pack failure
each time the IOA is IPLed and it can be ignored.
Failing Item:
If you are working with one of the card types below,
v CACHBAT
the adapter has mulitple physical parts. Choose the
card type to identify the physical parts of the storage
adapter. 572A8100 572A8100
Card type 2BE1 (feature RAID enablement card for Explanation: Licensed Internal Code error
embedded IOA) read the following: When working the
Response: If you are working with one of the card
FRUs from the serviceable event or the failing item list
types below, the adapter has mulitple physical parts.
here, the embedded storage adapter (STORIOA) has
Choose the card type to identify the physical parts of
three physical parts:
the storage adapter.
v The embedded storage adapter on the I/O
backplane. Card type 2BE1 (feature RAID enablement card for
Card type 57CB (embedded IOA with 2BCF battery Card type 57CB (embedded IOA with 2BCF battery
card for embedded IOA) read the following: When card for embedded IOA) read the following: When
working the FRUs from the serviceable event or the working the FRUs from the serviceable event or the
failing item list here, the embedded storage adapter failing item list here, the embedded storage adapter
(STORIOA) has two physical parts: (STORIOA) has two physical parts:
v The embedded storage adapter on the I/O v The embedded storage adapter on the I/O
backplane. backplane.
v The Battery charger and carrier card. v The Battery charger and carrier card.
See symbolic FRU FEATCRD for the location codes of See symbolic FRU FEATCRD for the location codes of
the FRUs if they are not listed in the serviceable event the FRUs if they are not listed in the serviceable event
or if you are working the failing item list here. or if you are working the failing item list here.
Card type 57CF (embedded IOAs on DASD backplane Card type 57CF (embedded IOAs on DASD backplane
with 2BC2 dual battery charger and carrier card for the with 2BC2 dual battery charger and carrier card for the
embedded IOAs) read the following: When working embedded IOAs) read the following: When working
the FRUs from the serviceable event or the failing item the FRUs from the serviceable event or the failing item
list here, the embedded storage adapters (STORIOA) list here, the embedded storage adapters (STORIOA)
have two physical parts: have two physical parts:
v The embedded storage adapter on the DASD v The embedded storage adapter on the DASD
backplane. backplane.
v The dual battery charger and carrier card. To v The dual battery charger and carrier card. To
determine which battery is connected to which determine which battery is connected to which
embedded IOA use the bus number of the IOA with embedded IOA use the bus number of the IOA with
symbolic FRU CACHBAT. symbolic FRU CACHBAT.
See symbolic FRU FEATCRD for the location code of See symbolic FRU FEATCRD for the location code of
the dual battery charger and carrier card if it is not the dual battery charger and carrier card if it is not
listed in the serviceable event or if you are working the listed in the serviceable event or if you are working the
failing item list here. failing item list here.
Failing Item: Failing Item:
v STORIOA v PTFSRCH
v ANYBRDG v STORIOA
See symbolic FRU FEATCRD for the location codes of See symbolic FRU FEATCRD for the location codes of
the FRUs if they are not listed in the serviceable event the FRUs if they are not listed in the serviceable event
or if you are working the failing item list here. or if you are working the failing item list here.
Card type 57CB (embedded IOA with 2BCF battery Card type 57CB (embedded IOA with 2BCF battery
card for embedded IOA) read the following: When card for embedded IOA) read the following: When
working the FRUs from the serviceable event or the working the FRUs from the serviceable event or the
failing item list here, the embedded storage adapter failing item list here, the embedded storage adapter
(STORIOA) has two physical parts: (STORIOA) has two physical parts:
v The embedded storage adapter on the I/O v The embedded storage adapter on the I/O
backplane. backplane.
v The Battery charger and carrier card. v The Battery charger and carrier card.
See symbolic FRU FEATCRD for the location codes of See symbolic FRU FEATCRD for the location codes of
the FRUs if they are not listed in the serviceable event the FRUs if they are not listed in the serviceable event
or if you are working the failing item list here. or if you are working the failing item list here.
Card type 57CF (embedded IOAs on DASD backplane Card type 57CF (embedded IOAs on DASD backplane
with 2BC2 dual battery charger and carrier card for the with 2BC2 dual battery charger and carrier card for the
embedded IOAs) read the following: When working embedded IOAs) read the following: When working
the FRUs from the serviceable event or the failing item the FRUs from the serviceable event or the failing item
list here, the embedded storage adapters (STORIOA) list here, the embedded storage adapters (STORIOA)
have two physical parts: have two physical parts:
v The embedded storage adapter on the DASD v The embedded storage adapter on the DASD
backplane. backplane.
v The dual battery charger and carrier card. To v The dual battery charger and carrier card. To
determine which battery is connected to which determine which battery is connected to which
embedded IOA use the bus number of the IOA with embedded IOA use the bus number of the IOA with
symbolic FRU CACHBAT. symbolic FRU CACHBAT.
See symbolic FRU FEATCRD for the location code of See symbolic FRU FEATCRD for the location code of
the dual battery charger and carrier card if it is not the dual battery charger and carrier card if it is not
listed in the serviceable event or if you are working the listed in the serviceable event or if you are working the
failing item list here. failing item list here.
Failing Item: Failing Item:
v PTFSRCH v PTFSRCH
v STORIOA v STORIOA
v The embedded storage adapter on the I/O v The embedded storage adapter on the I/O
backplane. backplane.
v The RAID enablement card. v The RAID enablement card.
v The Battery charger and carrier card. v The Battery charger and carrier card.
See symbolic FRU FEATCRD for the location codes of See symbolic FRU FEATCRD for the location codes of
the FRUs if they are not listed in the serviceable event the FRUs if they are not listed in the serviceable event
or if you are working the failing item list here. or if you are working the failing item list here.
Card type 57CB (embedded IOA with 2BCF battery Card type 57CB (embedded IOA with 2BCF battery
card for embedded IOA) read the following: When card for embedded IOA) read the following: When
working the FRUs from the serviceable event or the working the FRUs from the serviceable event or the
failing item list here, the embedded storage adapter failing item list here, the embedded storage adapter
(STORIOA) has two physical parts: (STORIOA) has two physical parts:
v The embedded storage adapter on the I/O v The embedded storage adapter on the I/O
backplane. backplane.
v The Battery charger and carrier card. v The Battery charger and carrier card.
See symbolic FRU FEATCRD for the location codes of See symbolic FRU FEATCRD for the location codes of
the FRUs if they are not listed in the serviceable event the FRUs if they are not listed in the serviceable event
or if you are working the failing item list here. or if you are working the failing item list here.
Card type 57CF (embedded IOAs on DASD backplane Card type 57CF (embedded IOAs on DASD backplane
with 2BC2 dual battery charger and carrier card for the with 2BC2 dual battery charger and carrier card for the
embedded IOAs) read the following: When working embedded IOAs) read the following: When working
the FRUs from the serviceable event or the failing item the FRUs from the serviceable event or the failing item
list here, the embedded storage adapters (STORIOA) list here, the embedded storage adapters (STORIOA)
have two physical parts: have two physical parts:
v The embedded storage adapter on the DASD v The embedded storage adapter on the DASD
backplane. backplane.
v The dual battery charger and carrier card. To v The dual battery charger and carrier card. To
determine which battery is connected to which determine which battery is connected to which
embedded IOA use the bus number of the IOA with embedded IOA use the bus number of the IOA with
symbolic FRU CACHBAT. symbolic FRU CACHBAT.
See symbolic FRU FEATCRD for the location code of See symbolic FRU FEATCRD for the location code of
the dual battery charger and carrier card if it is not the dual battery charger and carrier card if it is not
listed in the serviceable event or if you are working the listed in the serviceable event or if you are working the
failing item list here. failing item list here.
Failing Item: Failing Item:
v SVCDOCS v STORIOA
v STORIOA v ANYBRDG
v PTFSRCH
572A8300 572A8300
Explanation: IOA hardware error or PCI bus error 572A8301 572A8301
Response: If you are working with one of the card Explanation: Not valid condition in Licensed Internal
types below, the adapter has mulitple physical parts. Code
Choose the card type to identify the physical parts of Response: If you are working with one of the card
the storage adapter. types below, the adapter has mulitple physical parts.
Card type 2BE1 (feature RAID enablement card for Choose the card type to identify the physical parts of
embedded IOA) read the following: When working the the storage adapter.
FRUs from the serviceable event or the failing item list Card type 2BE1 (feature RAID enablement card for
here, the embedded storage adapter (STORIOA) has embedded IOA) read the following: When working the
three physical parts: FRUs from the serviceable event or the failing item list
here, the embedded storage adapter (STORIOA) has FRUs from the serviceable event or the failing item list
three physical parts: here, the embedded storage adapter (STORIOA) has
v The embedded storage adapter on the I/O three physical parts:
backplane. v The embedded storage adapter on the I/O
v The RAID enablement card. backplane.
v The Battery charger and carrier card. v The RAID enablement card.
v The Battery charger and carrier card.
See symbolic FRU FEATCRD for the location codes of
the FRUs if they are not listed in the serviceable event See symbolic FRU FEATCRD for the location codes of
or if you are working the failing item list here. the FRUs if they are not listed in the serviceable event
or if you are working the failing item list here.
Card type 57CB (embedded IOA with 2BCF battery
card for embedded IOA) read the following: When Card type 57CB (embedded IOA with 2BCF battery
working the FRUs from the serviceable event or the card for embedded IOA) read the following: When
failing item list here, the embedded storage adapter working the FRUs from the serviceable event or the
(STORIOA) has two physical parts: failing item list here, the embedded storage adapter
v The embedded storage adapter on the I/O (STORIOA) has two physical parts:
backplane. v The embedded storage adapter on the I/O
v The Battery charger and carrier card. backplane.
v The Battery charger and carrier card.
See symbolic FRU FEATCRD for the location codes of
the FRUs if they are not listed in the serviceable event See symbolic FRU FEATCRD for the location codes of
or if you are working the failing item list here. the FRUs if they are not listed in the serviceable event
or if you are working the failing item list here.
Card type 57CF (embedded IOAs on DASD backplane
with 2BC2 dual battery charger and carrier card for the Card type 57CF (embedded IOAs on DASD backplane
embedded IOAs) read the following: When working with 2BC2 dual battery charger and carrier card for the
the FRUs from the serviceable event or the failing item embedded IOAs) read the following: When working
list here, the embedded storage adapters (STORIOA) the FRUs from the serviceable event or the failing item
have two physical parts: list here, the embedded storage adapters (STORIOA)
v The embedded storage adapter on the DASD have two physical parts:
backplane. v The embedded storage adapter on the DASD
v The dual battery charger and carrier card. To backplane.
determine which battery is connected to which v The dual battery charger and carrier card. To
embedded IOA use the bus number of the IOA with determine which battery is connected to which
symbolic FRU CACHBAT. embedded IOA use the bus number of the IOA with
symbolic FRU CACHBAT.
See symbolic FRU FEATCRD for the location code of
the dual battery charger and carrier card if it is not See symbolic FRU FEATCRD for the location code of
listed in the serviceable event or if you are working the the dual battery charger and carrier card if it is not
failing item list here. listed in the serviceable event or if you are working the
failing item list here.
Failing Item:
v PTFSRCH Failing Item:
v STORIOA v SVCDOCS
v STORIOA
572A8302 572A8302
572A8400 572A8400
Explanation: Missing Licensed Internal Code
Explanation: Licensed Internal Code error
Response: Ensure that the code necessary to support
this I/O adapter is loaded. Failing Item:
If you are working with one of the card types below, v PTFSRCH
the adapter has mulitple physical parts. Choose the
card type to identify the physical parts of the storage
adapter.
Card type 2BE1 (feature RAID enablement card for
embedded IOA) read the following: When working the
v FI01105
572A8404 572A8404
v STORIOA
Explanation: System log entry only. No service action
required.
572A9001 572A9001
See symbolic FRU FEATCRD for the location codes of Failing Item:
the FRUs if they are not listed in the serviceable event v NEXTLVL
or if you are working the failing item list here.
572A9020 572A9020
Card type 57CF (embedded IOAs on DASD backplane
with 2BC2 dual battery charger and carrier card for the Explanation: Two or more disk units missing from
embedded IOAs) read the following: When working RAID-5 or RAID-6 array
the FRUs from the serviceable event or the failing item
Failing Item:
list here, the embedded storage adapters (STORIOA)
have two physical parts: v SIP3111
v The embedded storage adapter on the DASD
backplane. 572A9021 572A9021
v The dual battery charger and carrier card. To Explanation: Two or more disk units missing from
determine which battery is connected to which RAID-5 or RAID-6 array
embedded IOA use the bus number of the IOA with
symbolic FRU CACHBAT. Failing Item:
v SIP3111
See symbolic FRU FEATCRD for the location code of
the dual battery charger and carrier card if it is not
listed in the serviceable event or if you are working the
failing item list here.
Failing Item:
Failing Item:
572A9031 572A9031
v SIP3110
v FI02112 Explanation: Automatic rebuild initiated for array
Response: Either a previous rebuild was interrupted
572A9026 572A9026 and was automatically restarted, or a hot spare disk
unit was used to automatically rebuild the array. Look
Explanation: Disk unit not found at required physical for other reference codes and take action on them.
location
Response: A previously exposed disk unit in an array 572A9032 572A9032
was not found at the required physical location.
Explanation: A disk unit in an array is missing or
Failing Item: failed
v NEXTLVL
Response: The array is still protected, but the disk
unit should be replaced.
572A9027 572A9027
Failing Item:
Explanation: Array not functional due to parity out of v SIP3110
synchronization
v FI02112
Response: Array is or would become exposed and
parity data is out of synchronization
572A9040 572A9040
Failing Item:
Explanation: Re-synchronization of array parity was
v SIP3113 initiated
Response: No action required.
v The embedded storage adapter on the I/O v The embedded storage adapter on the I/O
backplane. backplane.
v The RAID enablement card. v The RAID enablement card.
v The Battery charger and carrier card. v The Battery charger and carrier card.
See symbolic FRU FEATCRD for the location codes of See symbolic FRU FEATCRD for the location codes of
the FRUs if they are not listed in the serviceable event the FRUs if they are not listed in the serviceable event
or if you are working the failing item list here. or if you are working the failing item list here.
Card type 57CB (embedded IOA with 2BCF battery Card type 57CB (embedded IOA with 2BCF battery
card for embedded IOA) read the following: When card for embedded IOA) read the following: When
working the FRUs from the serviceable event or the working the FRUs from the serviceable event or the
failing item list here, the embedded storage adapter failing item list here, the embedded storage adapter
(STORIOA) has two physical parts: (STORIOA) has two physical parts:
v The embedded storage adapter on the I/O v The embedded storage adapter on the I/O
backplane. backplane.
v The Battery charger and carrier card. v The Battery charger and carrier card.
See symbolic FRU FEATCRD for the location codes of See symbolic FRU FEATCRD for the location codes of
the FRUs if they are not listed in the serviceable event the FRUs if they are not listed in the serviceable event
or if you are working the failing item list here. or if you are working the failing item list here.
Card type 57CF (embedded IOAs on DASD backplane Card type 57CF (embedded IOAs on DASD backplane
with 2BC2 dual battery charger and carrier card for the with 2BC2 dual battery charger and carrier card for the
embedded IOAs) read the following: When working embedded IOAs) read the following: When working
the FRUs from the serviceable event or the failing item the FRUs from the serviceable event or the failing item
list here, the embedded storage adapters (STORIOA) list here, the embedded storage adapters (STORIOA)
have two physical parts: have two physical parts:
v The embedded storage adapter on the DASD v The embedded storage adapter on the DASD
backplane. backplane.
v The dual battery charger and carrier card. To v The dual battery charger and carrier card. To
determine which battery is connected to which determine which battery is connected to which
embedded IOA use the bus number of the IOA with embedded IOA use the bus number of the IOA with
symbolic FRU CACHBAT. symbolic FRU CACHBAT.
See symbolic FRU FEATCRD for the location code of See symbolic FRU FEATCRD for the location code of
the dual battery charger and carrier card if it is not the dual battery charger and carrier card if it is not
listed in the serviceable event or if you are working the listed in the serviceable event or if you are working the
failing item list here. failing item list here.
Failing Item: Failing Item:
v FI01105 v FI01105
v STORIOA v STORIOA
If you cannot resolve the problem, contact your next Explanation: I/O adapter detected a recoverable error
level of support. Response: If you are working with one of the card
Failing Item: types below, the adapter has mulitple physical parts.
Choose the card type to identify the physical parts of
v SVCDOCS
the storage adapter.
Card type 2BE1 (feature RAID enablement card for
572A9091 572A9091
embedded IOA) read the following: When working the
Explanation: Incorrect hardware configuration change FRUs from the serviceable event or the failing item list
detected here, the embedded storage adapter (STORIOA) has
three physical parts:
Response: Use Hardware Service Manager to re-IPL
the virtual I/O processor that is associated with this v The embedded storage adapter on the I/O
I/O adapter. Other resources attached to the virtual backplane.
I/O processor may then need to be Varied On. v The RAID enablement card.
If any reference codes are surfaced, use the new v The Battery charger and carrier card.
reference code to resolve the problem.
See symbolic FRU FEATCRD for the location codes of
If you cannot resolve the problem, contact your next the FRUs if they are not listed in the serviceable event
level of support. or if you are working the failing item list here.
Failing Item:
Card type 57CB (embedded IOA with 2BCF battery
v SVCDOCS
card for embedded IOA) read the following: When
working the FRUs from the serviceable event or the
572A9092 572A9092 failing item list here, the embedded storage adapter
(STORIOA) has two physical parts:
Explanation: Disk unit requires initialization before
use. v The embedded storage adapter on the I/O
backplane.
Failing Item:
v The Battery charger and carrier card.
v SIP3134
See symbolic FRU FEATCRD for the location codes of
572A9500 572A9500 the FRUs if they are not listed in the serviceable event
or if you are working the failing item list here.
Explanation: Internal program error in driver code.
Failing Item: Card type 57CF (embedded IOAs on DASD backplane
with 2BC2 dual battery charger and carrier card for the
v PTFSRCH
embedded IOAs) read the following: When working
the FRUs from the serviceable event or the failing item
572A9903 572A9903 list here, the embedded storage adapters (STORIOA)
have two physical parts:
Explanation: Tape device information was logged.
Informational event, no service required. v The embedded storage adapter on the DASD
backplane.
v The dual battery charger and carrier card. To
572AC000 572AC000 determine which battery is connected to which
Explanation: System log entry only. No service action embedded IOA use the bus number of the IOA with
required. symbolic FRU CACHBAT.
v The embedded storage adapter on the I/O Card type 2BE1 (feature RAID enablement card for
backplane. embedded IOA) read the following: When working the
v The RAID enablement card. FRUs from the serviceable event or the failing item list
here, the embedded storage adapter (STORIOA) has
v The Battery charger and carrier card. three physical parts:
v The embedded storage adapter on the I/O
See symbolic FRU FEATCRD for the location codes of
backplane.
the FRUs if they are not listed in the serviceable event
or if you are working the failing item list here. v The RAID enablement card.
v The Battery charger and carrier card.
Card type 57CB (embedded IOA with 2BCF battery
card for embedded IOA) read the following: When See symbolic FRU FEATCRD for the location codes of
working the FRUs from the serviceable event or the the FRUs if they are not listed in the serviceable event
failing item list here, the embedded storage adapter or if you are working the failing item list here.
(STORIOA) has two physical parts:
Card type 57CB (embedded IOA with 2BCF battery v The RAID enablement card.
card for embedded IOA) read the following: When v The Battery charger and carrier card.
working the FRUs from the serviceable event or the
failing item list here, the embedded storage adapter See symbolic FRU FEATCRD for the location codes of
(STORIOA) has two physical parts: the FRUs if they are not listed in the serviceable event
v The embedded storage adapter on the I/O or if you are working the failing item list here.
backplane.
v The Battery charger and carrier card. Card type 57CB (embedded IOA with 2BCF battery
card) read the following: When working the FRUs from
See symbolic FRU FEATCRD for the location codes of the serviceable event or the failing item list here, the
the FRUs if they are not listed in the serviceable event embedded storage adapter (STORIOA) has two
or if you are working the failing item list here. physical parts:
v The embedded storage adapter on the I/O
Card type 57CF (embedded IOAs on DASD backplane backplane.
with 2BC2 dual battery charger and carrier card for the v The Battery charger and carrier card.
embedded IOAs) read the following: When working
the FRUs from the serviceable event or the failing item See symbolic FRU FEATCRD for the location codes of
list here, the embedded storage adapters (STORIOA) the FRUs if they are not listed in the serviceable event
have two physical parts: or if you are working the failing item list here.
v The embedded storage adapter on the DASD
backplane. Card type 57CF (embedded IOAs on DASD backplane
v The dual battery charger and carrier card. To with 2BC2 dual battery charger and carrier card) read
determine which battery is connected to which the following: When working the FRUs from the
embedded IOA use the bus number of the IOA with serviceable event or the failing item list here, the
symbolic FRU CACHBAT. embedded storage adapters (STORIOA) have two
physical parts:
See symbolic FRU FEATCRD for the location code of v The embedded storage adapter on the DASD
the dual battery charger and carrier card if it is not backplane.
listed in the serviceable event or if you are working the v The dual battery charger and carrier card. To
failing item list here. determine which battery is connected to which
Failing Item: embedded IOA use the bus number of the IOA with
symbolic FRU CACHBAT.
v BACKPLN
v STORIOA See symbolic FRU FEATCRD for the location code of
the dual battery charger and carrier card if it is not
572B8008 572B8008 listed in the serviceable event or if you are working the
failing item list here.
Explanation: A permanent cache battery pack failure
occurred Failing Item:
v CACHBAT
Response: Under a certain configuration, this SRC
may not represent an error that requires a service v STORIOA
action. Depending on the configuration of the system, v FEATCRD
the Storage IOA may have been altered and/or the
Storage IOA Cache may have been disabled to allow
attachment of OEM Storage that emulates a Load 572B8009 572B8009
Source drive. If this is the case, this error will be posted Explanation: Impending cache battery pack failure
each time the IOA is IPLed and it can be ignored.
Failing Item:
If you are working with one of the card types below,
v CACHBAT
the adapter has mulitple physical parts. Choose the
card type to identify the physical parts of the storage
adapter. 572B8100 572B8100
Card type 2BE1 (feature RAID enablement card for Explanation: Licensed Internal Code error
embedded IOA) read the following: When working the
Response: If you are working with one of the card
FRUs from the serviceable event or the failing item list
types below, the adapter has mulitple physical parts.
here, the embedded storage adapter (STORIOA) has
Choose the card type to identify the physical parts of
three physical parts:
the storage adapter.
v The embedded storage adapter on the I/O
backplane. Card type 2BE1 (feature RAID enablement card for
Card type 57CB (embedded IOA with 2BCF battery Card type 57CB (embedded IOA with 2BCF battery
card for embedded IOA) read the following: When card for embedded IOA) read the following: When
working the FRUs from the serviceable event or the working the FRUs from the serviceable event or the
failing item list here, the embedded storage adapter failing item list here, the embedded storage adapter
(STORIOA) has two physical parts: (STORIOA) has two physical parts:
v The embedded storage adapter on the I/O v The embedded storage adapter on the I/O
backplane. backplane.
v The Battery charger and carrier card. v The Battery charger and carrier card.
See symbolic FRU FEATCRD for the location codes of See symbolic FRU FEATCRD for the location codes of
the FRUs if they are not listed in the serviceable event the FRUs if they are not listed in the serviceable event
or if you are working the failing item list here. or if you are working the failing item list here.
Card type 57CF (embedded IOAs on DASD backplane Card type 57CF (embedded IOAs on DASD backplane
with 2BC2 dual battery charger and carrier card for the with 2BC2 dual battery charger and carrier card for the
embedded IOAs) read the following: When working embedded IOAs) read the following: When working
the FRUs from the serviceable event or the failing item the FRUs from the serviceable event or the failing item
list here, the embedded storage adapters (STORIOA) list here, the embedded storage adapters (STORIOA)
have two physical parts: have two physical parts:
v The embedded storage adapter on the DASD v The embedded storage adapter on the DASD
backplane. backplane.
v The dual battery charger and carrier card. To v The dual battery charger and carrier card. To
determine which battery is connected to which determine which battery is connected to which
embedded IOA use the bus number of the IOA with embedded IOA use the bus number of the IOA with
symbolic FRU CACHBAT. symbolic FRU CACHBAT.
See symbolic FRU FEATCRD for the location code of See symbolic FRU FEATCRD for the location code of
the dual battery charger and carrier card if it is not the dual battery charger and carrier card if it is not
listed in the serviceable event or if you are working the listed in the serviceable event or if you are working the
failing item list here. failing item list here.
Failing Item: Failing Item:
v STORIOA v PTFSRCH
v ANYBRDG v STORIOA
See symbolic FRU FEATCRD for the location codes of See symbolic FRU FEATCRD for the location codes of
the FRUs if they are not listed in the serviceable event the FRUs if they are not listed in the serviceable event
or if you are working the failing item list here. or if you are working the failing item list here.
Card type 57CB (embedded IOA with 2BCF battery Card type 57CB (embedded IOA with 2BCF battery
card for embedded IOA) read the following: When card for embedded IOA) read the following: When
working the FRUs from the serviceable event or the working the FRUs from the serviceable event or the
failing item list here, the embedded storage adapter failing item list here, the embedded storage adapter
(STORIOA) has two physical parts: (STORIOA) has two physical parts:
v The embedded storage adapter on the I/O v The embedded storage adapter on the I/O
backplane. backplane.
v The Battery charger and carrier card. v The Battery charger and carrier card.
See symbolic FRU FEATCRD for the location codes of See symbolic FRU FEATCRD for the location codes of
the FRUs if they are not listed in the serviceable event the FRUs if they are not listed in the serviceable event
or if you are working the failing item list here. or if you are working the failing item list here.
Card type 57CF (embedded IOAs on DASD backplane Card type 57CF (embedded IOAs on DASD backplane
with 2BC2 dual battery charger and carrier card for the with 2BC2 dual battery charger and carrier card for the
embedded IOAs) read the following: When working embedded IOAs) read the following: When working
the FRUs from the serviceable event or the failing item the FRUs from the serviceable event or the failing item
list here, the embedded storage adapters (STORIOA) list here, the embedded storage adapters (STORIOA)
have two physical parts: have two physical parts:
v The embedded storage adapter on the DASD v The embedded storage adapter on the DASD
backplane. backplane.
v The dual battery charger and carrier card. To v The dual battery charger and carrier card. To
determine which battery is connected to which determine which battery is connected to which
embedded IOA use the bus number of the IOA with embedded IOA use the bus number of the IOA with
symbolic FRU CACHBAT. symbolic FRU CACHBAT.
See symbolic FRU FEATCRD for the location code of See symbolic FRU FEATCRD for the location code of
the dual battery charger and carrier card if it is not the dual battery charger and carrier card if it is not
listed in the serviceable event or if you are working the listed in the serviceable event or if you are working the
failing item list here. failing item list here.
Failing Item: Failing Item:
v PTFSRCH v PTFSRCH
v STORIOA v STORIOA
v The embedded storage adapter on the I/O v The embedded storage adapter on the I/O
backplane. backplane.
v The RAID enablement card. v The RAID enablement card.
v The Battery charger and carrier card. v The Battery charger and carrier card.
See symbolic FRU FEATCRD for the location codes of See symbolic FRU FEATCRD for the location codes of
the FRUs if they are not listed in the serviceable event the FRUs if they are not listed in the serviceable event
or if you are working the failing item list here. or if you are working the failing item list here.
Card type 57CB (embedded IOA with 2BCF battery Card type 57CB (embedded IOA with 2BCF battery
card for embedded IOA) read the following: When card for embedded IOA) read the following: When
working the FRUs from the serviceable event or the working the FRUs from the serviceable event or the
failing item list here, the embedded storage adapter failing item list here, the embedded storage adapter
(STORIOA) has two physical parts: (STORIOA) has two physical parts:
v The embedded storage adapter on the I/O v The embedded storage adapter on the I/O
backplane. backplane.
v The Battery charger and carrier card. v The Battery charger and carrier card.
See symbolic FRU FEATCRD for the location codes of See symbolic FRU FEATCRD for the location codes of
the FRUs if they are not listed in the serviceable event the FRUs if they are not listed in the serviceable event
or if you are working the failing item list here. or if you are working the failing item list here.
Card type 57CF (embedded IOAs on DASD backplane Card type 57CF (embedded IOAs on DASD backplane
with 2BC2 dual battery charger and carrier card for the with 2BC2 dual battery charger and carrier card for the
embedded IOAs) read the following: When working embedded IOAs) read the following: When working
the FRUs from the serviceable event or the failing item the FRUs from the serviceable event or the failing item
list here, the embedded storage adapters (STORIOA) list here, the embedded storage adapters (STORIOA)
have two physical parts: have two physical parts:
v The embedded storage adapter on the DASD v The embedded storage adapter on the DASD
backplane. backplane.
v The dual battery charger and carrier card. To v The dual battery charger and carrier card. To
determine which battery is connected to which determine which battery is connected to which
embedded IOA use the bus number of the IOA with embedded IOA use the bus number of the IOA with
symbolic FRU CACHBAT. symbolic FRU CACHBAT.
See symbolic FRU FEATCRD for the location code of See symbolic FRU FEATCRD for the location code of
the dual battery charger and carrier card if it is not the dual battery charger and carrier card if it is not
listed in the serviceable event or if you are working the listed in the serviceable event or if you are working the
failing item list here. failing item list here.
Failing Item: Failing Item:
v SVCDOCS v STORIOA
v STORIOA v ANYBRDG
v PTFSRCH
572B8300 572B8300
Explanation: IOA hardware error or PCI bus error 572B8301 572B8301
Response: If you are working with one of the card Explanation: Not valid condition in Licensed Internal
types below, the adapter has mulitple physical parts. Code
Choose the card type to identify the physical parts of Response: If you are working with one of the card
the storage adapter. types below, the adapter has mulitple physical parts.
Card type 2BE1 (feature RAID enablement card for Choose the card type to identify the physical parts of
embedded IOA) read the following: When working the the storage adapter.
FRUs from the serviceable event or the failing item list Card type 2BE1 (feature RAID enablement card for
here, the embedded storage adapter (STORIOA) has embedded IOA) read the following: When working the
three physical parts: FRUs from the serviceable event or the failing item list
here, the embedded storage adapter (STORIOA) has FRUs from the serviceable event or the failing item list
three physical parts: here, the embedded storage adapter (STORIOA) has
v The embedded storage adapter on the I/O three physical parts:
backplane. v The embedded storage adapter on the I/O
v The RAID enablement card. backplane.
v The Battery charger and carrier card. v The RAID enablement card.
v The Battery charger and carrier card.
See symbolic FRU FEATCRD for the location codes of
the FRUs if they are not listed in the serviceable event See symbolic FRU FEATCRD for the location codes of
or if you are working the failing item list here. the FRUs if they are not listed in the serviceable event
or if you are working the failing item list here.
Card type 57CB (embedded IOA with 2BCF battery
card for embedded IOA) read the following: When Card type 57CB (embedded IOA with 2BCF battery
working the FRUs from the serviceable event or the card for embedded IOA) read the following: When
failing item list here, the embedded storage adapter working the FRUs from the serviceable event or the
(STORIOA) has two physical parts: failing item list here, the embedded storage adapter
v The embedded storage adapter on the I/O (STORIOA) has two physical parts:
backplane. v The embedded storage adapter on the I/O
v The Battery charger and carrier card. backplane.
v The Battery charger and carrier card.
See symbolic FRU FEATCRD for the location codes of
the FRUs if they are not listed in the serviceable event See symbolic FRU FEATCRD for the location codes of
or if you are working the failing item list here. the FRUs if they are not listed in the serviceable event
or if you are working the failing item list here.
Card type 57CF (embedded IOAs on DASD backplane
with 2BC2 dual battery charger and carrier card for the Card type 57CF (embedded IOAs on DASD backplane
embedded IOAs) read the following: When working with 2BC2 dual battery charger and carrier card for the
the FRUs from the serviceable event or the failing item embedded IOAs) read the following: When working
list here, the embedded storage adapters (STORIOA) the FRUs from the serviceable event or the failing item
have two physical parts: list here, the embedded storage adapters (STORIOA)
v The embedded storage adapter on the DASD have two physical parts:
backplane. v The embedded storage adapter on the DASD
v The dual battery charger and carrier card. To backplane.
determine which battery is connected to which v The dual battery charger and carrier card. To
embedded IOA use the bus number of the IOA with determine which battery is connected to which
symbolic FRU CACHBAT. embedded IOA use the bus number of the IOA with
symbolic FRU CACHBAT.
See symbolic FRU FEATCRD for the location code of
the dual battery charger and carrier card if it is not See symbolic FRU FEATCRD for the location code of
listed in the serviceable event or if you are working the the dual battery charger and carrier card if it is not
failing item list here. listed in the serviceable event or if you are working the
failing item list here.
Failing Item:
v PTFSRCH Failing Item:
v STORIOA v SVCDOCS
v STORIOA
572B8302 572B8302
572B8400 572B8400
Explanation: Missing Licensed Internal Code
Explanation: Licensed Internal Code error
Response: Ensure that the code necessary to support
this I/O adapter is loaded. Failing Item:
If you are working with one of the card types below, v PTFSRCH
the adapter has mulitple physical parts. Choose the
card type to identify the physical parts of the storage
adapter.
Card type 2BE1 (feature RAID enablement card for
embedded IOA) read the following: When working the
v FI01105
572B8404 572B8404
v STORIOA
Explanation: System log entry only. No service action
required.
572B9001 572B9001
See symbolic FRU FEATCRD for the location codes of Failing Item:
the FRUs if they are not listed in the serviceable event v NEXTLVL
or if you are working the failing item list here.
572B9020 572B9020
Card type 57CF (embedded IOAs on DASD backplane
with 2BC2 dual battery charger and carrier card for the Explanation: Two or more disk units missing from
embedded IOAs) read the following: When working RAID-5 or RAID-6 array
the FRUs from the serviceable event or the failing item
Failing Item:
list here, the embedded storage adapters (STORIOA)
have two physical parts: v SIP3111
v The embedded storage adapter on the DASD
backplane. 572B9021 572B9021
v The dual battery charger and carrier card. To Explanation: Two or more disk units missing from
determine which battery is connected to which RAID-5 or RAID-6 array
embedded IOA use the bus number of the IOA with
symbolic FRU CACHBAT. Failing Item:
v SIP3111
See symbolic FRU FEATCRD for the location code of
the dual battery charger and carrier card if it is not
listed in the serviceable event or if you are working the
failing item list here.
Failing Item:
Failing Item:
572B9031 572B9031
v SIP3110
v FI02112 Explanation: Automatic rebuild initiated for array
Response: Either a previous rebuild was interrupted
572B9026 572B9026 and was automatically restarted, or a hot spare disk
unit was used to automatically rebuild the array. Look
Explanation: Disk unit not found at required physical for other reference codes and take action on them.
location
Response: A previously exposed disk unit in an array 572B9032 572B9032
was not found at the required physical location.
Explanation: A disk unit in an array is missing or
Failing Item: failed
v NEXTLVL
Response: The array is still protected, but the disk
unit should be replaced.
572B9027 572B9027
Failing Item:
Explanation: Array not functional due to parity out of v SIP3110
synchronization
v FI02112
Response: Array is or would become exposed and
parity data is out of synchronization
572B9040 572B9040
Failing Item:
Explanation: Re-synchronization of array parity was
v SIP3113 initiated
Response: No action required.
v The embedded storage adapter on the I/O v The embedded storage adapter on the I/O
backplane. backplane.
v The RAID enablement card. v The RAID enablement card.
v The Battery charger and carrier card. v The Battery charger and carrier card.
See symbolic FRU FEATCRD for the location codes of See symbolic FRU FEATCRD for the location codes of
the FRUs if they are not listed in the serviceable event the FRUs if they are not listed in the serviceable event
or if you are working the failing item list here. or if you are working the failing item list here.
Card type 57CB (embedded IOA with 2BCF battery Card type 57CB (embedded IOA with 2BCF battery
card for embedded IOA) read the following: When card for embedded IOA) read the following: When
working the FRUs from the serviceable event or the working the FRUs from the serviceable event or the
failing item list here, the embedded storage adapter failing item list here, the embedded storage adapter
(STORIOA) has two physical parts: (STORIOA) has two physical parts:
v The embedded storage adapter on the I/O v The embedded storage adapter on the I/O
backplane. backplane.
v The Battery charger and carrier card. v The Battery charger and carrier card.
See symbolic FRU FEATCRD for the location codes of See symbolic FRU FEATCRD for the location codes of
the FRUs if they are not listed in the serviceable event the FRUs if they are not listed in the serviceable event
or if you are working the failing item list here. or if you are working the failing item list here.
Card type 57CF (embedded IOAs on DASD backplane Card type 57CF (embedded IOAs on DASD backplane
with 2BC2 dual battery charger and carrier card for the with 2BC2 dual battery charger and carrier card for the
embedded IOAs) read the following: When working embedded IOAs) read the following: When working
the FRUs from the serviceable event or the failing item the FRUs from the serviceable event or the failing item
list here, the embedded storage adapters (STORIOA) list here, the embedded storage adapters (STORIOA)
have two physical parts: have two physical parts:
v The embedded storage adapter on the DASD v The embedded storage adapter on the DASD
backplane. backplane.
v The dual battery charger and carrier card. To v The dual battery charger and carrier card. To
determine which battery is connected to which determine which battery is connected to which
embedded IOA use the bus number of the IOA with embedded IOA use the bus number of the IOA with
symbolic FRU CACHBAT. symbolic FRU CACHBAT.
See symbolic FRU FEATCRD for the location code of See symbolic FRU FEATCRD for the location code of
the dual battery charger and carrier card if it is not the dual battery charger and carrier card if it is not
listed in the serviceable event or if you are working the listed in the serviceable event or if you are working the
failing item list here. failing item list here.
Failing Item: Failing Item:
v FI01105 v FI01105
v STORIOA v STORIOA
If you cannot resolve the problem, contact your next Explanation: I/O adapter detected a recoverable error
level of support. Response: If you are working with one of the card
Failing Item: types below, the adapter has mulitple physical parts.
Choose the card type to identify the physical parts of
v SVCDOCS
the storage adapter.
Card type 2BE1 (feature RAID enablement card for
572B9091 572B9091
embedded IOA) read the following: When working the
Explanation: Incorrect hardware configuration change FRUs from the serviceable event or the failing item list
detected here, the embedded storage adapter (STORIOA) has
three physical parts:
Response: Use Hardware Service Manager to re-IPL
the virtual I/O processor that is associated with this v The embedded storage adapter on the I/O
I/O adapter. Other resources attached to the virtual backplane.
I/O processor may then need to be Varied On. v The RAID enablement card.
If any reference codes are surfaced, use the new v The Battery charger and carrier card.
reference code to resolve the problem.
See symbolic FRU FEATCRD for the location codes of
If you cannot resolve the problem, contact your next the FRUs if they are not listed in the serviceable event
level of support. or if you are working the failing item list here.
Failing Item:
Card type 57CB (embedded IOA with 2BCF battery
v SVCDOCS
card for embedded IOA) read the following: When
working the FRUs from the serviceable event or the
572B9092 572B9092 failing item list here, the embedded storage adapter
(STORIOA) has two physical parts:
Explanation: Disk unit requires initialization before
use. v The embedded storage adapter on the I/O
backplane.
Failing Item:
v The Battery charger and carrier card.
v SIP3134
See symbolic FRU FEATCRD for the location codes of
572B9500 572B9500 the FRUs if they are not listed in the serviceable event
or if you are working the failing item list here.
Explanation: Internal program error in driver code.
Failing Item: Card type 57CF (embedded IOAs on DASD backplane
with 2BC2 dual battery charger and carrier card for the
v PTFSRCH
embedded IOAs) read the following: When working
the FRUs from the serviceable event or the failing item
572B9903 572B9903 list here, the embedded storage adapters (STORIOA)
have two physical parts:
Explanation: Tape device information was logged.
Informational event, no service required. v The embedded storage adapter on the DASD
backplane.
v The dual battery charger and carrier card. To
572BC000 572BC000 determine which battery is connected to which
Explanation: System log entry only. No service action embedded IOA use the bus number of the IOA with
required. symbolic FRU CACHBAT.
v The embedded storage adapter on the I/O Card type 2BE1 (feature RAID enablement card for
backplane. embedded IOA) read the following: When working the
v The RAID enablement card. FRUs from the serviceable event or the failing item list
here, the embedded storage adapter (STORIOA) has
v The Battery charger and carrier card. three physical parts:
v The embedded storage adapter on the I/O
See symbolic FRU FEATCRD for the location codes of
backplane.
the FRUs if they are not listed in the serviceable event
or if you are working the failing item list here. v The RAID enablement card.
v The Battery charger and carrier card.
Card type 57CB (embedded IOA with 2BCF battery
card for embedded IOA) read the following: When See symbolic FRU FEATCRD for the location codes of
working the FRUs from the serviceable event or the the FRUs if they are not listed in the serviceable event
failing item list here, the embedded storage adapter or if you are working the failing item list here.
(STORIOA) has two physical parts:
Card type 57CB (embedded IOA with 2BCF battery v The RAID enablement card.
card for embedded IOA) read the following: When v The Battery charger and carrier card.
working the FRUs from the serviceable event or the
failing item list here, the embedded storage adapter See symbolic FRU FEATCRD for the location codes of
(STORIOA) has two physical parts: the FRUs if they are not listed in the serviceable event
v The embedded storage adapter on the I/O or if you are working the failing item list here.
backplane.
v The Battery charger and carrier card. Card type 57CB (embedded IOA with 2BCF battery
card) read the following: When working the FRUs from
See symbolic FRU FEATCRD for the location codes of the serviceable event or the failing item list here, the
the FRUs if they are not listed in the serviceable event embedded storage adapter (STORIOA) has two
or if you are working the failing item list here. physical parts:
v The embedded storage adapter on the I/O
Card type 57CF (embedded IOAs on DASD backplane backplane.
with 2BC2 dual battery charger and carrier card for the v The Battery charger and carrier card.
embedded IOAs) read the following: When working
the FRUs from the serviceable event or the failing item See symbolic FRU FEATCRD for the location codes of
list here, the embedded storage adapters (STORIOA) the FRUs if they are not listed in the serviceable event
have two physical parts: or if you are working the failing item list here.
v The embedded storage adapter on the DASD
backplane. Card type 57CF (embedded IOAs on DASD backplane
v The dual battery charger and carrier card. To with 2BC2 dual battery charger and carrier card) read
determine which battery is connected to which the following: When working the FRUs from the
embedded IOA use the bus number of the IOA with serviceable event or the failing item list here, the
symbolic FRU CACHBAT. embedded storage adapters (STORIOA) have two
physical parts:
See symbolic FRU FEATCRD for the location code of v The embedded storage adapter on the DASD
the dual battery charger and carrier card if it is not backplane.
listed in the serviceable event or if you are working the v The dual battery charger and carrier card. To
failing item list here. determine which battery is connected to which
Failing Item: embedded IOA use the bus number of the IOA with
symbolic FRU CACHBAT.
v BACKPLN
v STORIOA See symbolic FRU FEATCRD for the location code of
the dual battery charger and carrier card if it is not
572C8008 572C8008 listed in the serviceable event or if you are working the
failing item list here.
Explanation: A permanent cache battery pack failure
occurred Failing Item:
v CACHBAT
Response: Under a certain configuration, this SRC
may not represent an error that requires a service v STORIOA
action. Depending on the configuration of the system, v FEATCRD
the Storage IOA may have been altered and/or the
Storage IOA Cache may have been disabled to allow
attachment of OEM Storage that emulates a Load 572C8009 572C8009
Source drive. If this is the case, this error will be posted Explanation: Impending cache battery pack failure
each time the IOA is IPLed and it can be ignored.
Failing Item:
If you are working with one of the card types below,
v CACHBAT
the adapter has mulitple physical parts. Choose the
card type to identify the physical parts of the storage
adapter. 572C8100 572C8100
Card type 2BE1 (feature RAID enablement card for Explanation: Licensed Internal Code error
embedded IOA) read the following: When working the
Response: If you are working with one of the card
FRUs from the serviceable event or the failing item list
types below, the adapter has mulitple physical parts.
here, the embedded storage adapter (STORIOA) has
Choose the card type to identify the physical parts of
three physical parts:
the storage adapter.
v The embedded storage adapter on the I/O
backplane. Card type 2BE1 (feature RAID enablement card for
Card type 57CB (embedded IOA with 2BCF battery Card type 57CB (embedded IOA with 2BCF battery
card for embedded IOA) read the following: When card for embedded IOA) read the following: When
working the FRUs from the serviceable event or the working the FRUs from the serviceable event or the
failing item list here, the embedded storage adapter failing item list here, the embedded storage adapter
(STORIOA) has two physical parts: (STORIOA) has two physical parts:
v The embedded storage adapter on the I/O v The embedded storage adapter on the I/O
backplane. backplane.
v The Battery charger and carrier card. v The Battery charger and carrier card.
See symbolic FRU FEATCRD for the location codes of See symbolic FRU FEATCRD for the location codes of
the FRUs if they are not listed in the serviceable event the FRUs if they are not listed in the serviceable event
or if you are working the failing item list here. or if you are working the failing item list here.
Card type 57CF (embedded IOAs on DASD backplane Card type 57CF (embedded IOAs on DASD backplane
with 2BC2 dual battery charger and carrier card for the with 2BC2 dual battery charger and carrier card for the
embedded IOAs) read the following: When working embedded IOAs) read the following: When working
the FRUs from the serviceable event or the failing item the FRUs from the serviceable event or the failing item
list here, the embedded storage adapters (STORIOA) list here, the embedded storage adapters (STORIOA)
have two physical parts: have two physical parts:
v The embedded storage adapter on the DASD v The embedded storage adapter on the DASD
backplane. backplane.
v The dual battery charger and carrier card. To v The dual battery charger and carrier card. To
determine which battery is connected to which determine which battery is connected to which
embedded IOA use the bus number of the IOA with embedded IOA use the bus number of the IOA with
symbolic FRU CACHBAT. symbolic FRU CACHBAT.
See symbolic FRU FEATCRD for the location code of See symbolic FRU FEATCRD for the location code of
the dual battery charger and carrier card if it is not the dual battery charger and carrier card if it is not
listed in the serviceable event or if you are working the listed in the serviceable event or if you are working the
failing item list here. failing item list here.
Failing Item: Failing Item:
v STORIOA v PTFSRCH
v ANYBRDG v STORIOA
See symbolic FRU FEATCRD for the location codes of See symbolic FRU FEATCRD for the location codes of
the FRUs if they are not listed in the serviceable event the FRUs if they are not listed in the serviceable event
or if you are working the failing item list here. or if you are working the failing item list here.
Card type 57CB (embedded IOA with 2BCF battery Card type 57CB (embedded IOA with 2BCF battery
card for embedded IOA) read the following: When card for embedded IOA) read the following: When
working the FRUs from the serviceable event or the working the FRUs from the serviceable event or the
failing item list here, the embedded storage adapter failing item list here, the embedded storage adapter
(STORIOA) has two physical parts: (STORIOA) has two physical parts:
v The embedded storage adapter on the I/O v The embedded storage adapter on the I/O
backplane. backplane.
v The Battery charger and carrier card. v The Battery charger and carrier card.
See symbolic FRU FEATCRD for the location codes of See symbolic FRU FEATCRD for the location codes of
the FRUs if they are not listed in the serviceable event the FRUs if they are not listed in the serviceable event
or if you are working the failing item list here. or if you are working the failing item list here.
Card type 57CF (embedded IOAs on DASD backplane Card type 57CF (embedded IOAs on DASD backplane
with 2BC2 dual battery charger and carrier card for the with 2BC2 dual battery charger and carrier card for the
embedded IOAs) read the following: When working embedded IOAs) read the following: When working
the FRUs from the serviceable event or the failing item the FRUs from the serviceable event or the failing item
list here, the embedded storage adapters (STORIOA) list here, the embedded storage adapters (STORIOA)
have two physical parts: have two physical parts:
v The embedded storage adapter on the DASD v The embedded storage adapter on the DASD
backplane. backplane.
v The dual battery charger and carrier card. To v The dual battery charger and carrier card. To
determine which battery is connected to which determine which battery is connected to which
embedded IOA use the bus number of the IOA with embedded IOA use the bus number of the IOA with
symbolic FRU CACHBAT. symbolic FRU CACHBAT.
See symbolic FRU FEATCRD for the location code of See symbolic FRU FEATCRD for the location code of
the dual battery charger and carrier card if it is not the dual battery charger and carrier card if it is not
listed in the serviceable event or if you are working the listed in the serviceable event or if you are working the
failing item list here. failing item list here.
Failing Item: Failing Item:
v PTFSRCH v PTFSRCH
v STORIOA v STORIOA
v The embedded storage adapter on the I/O v The embedded storage adapter on the I/O
backplane. backplane.
v The RAID enablement card. v The RAID enablement card.
v The Battery charger and carrier card. v The Battery charger and carrier card.
See symbolic FRU FEATCRD for the location codes of See symbolic FRU FEATCRD for the location codes of
the FRUs if they are not listed in the serviceable event the FRUs if they are not listed in the serviceable event
or if you are working the failing item list here. or if you are working the failing item list here.
Card type 57CB (embedded IOA with 2BCF battery Card type 57CB (embedded IOA with 2BCF battery
card for embedded IOA) read the following: When card for embedded IOA) read the following: When
working the FRUs from the serviceable event or the working the FRUs from the serviceable event or the
failing item list here, the embedded storage adapter failing item list here, the embedded storage adapter
(STORIOA) has two physical parts: (STORIOA) has two physical parts:
v The embedded storage adapter on the I/O v The embedded storage adapter on the I/O
backplane. backplane.
v The Battery charger and carrier card. v The Battery charger and carrier card.
See symbolic FRU FEATCRD for the location codes of See symbolic FRU FEATCRD for the location codes of
the FRUs if they are not listed in the serviceable event the FRUs if they are not listed in the serviceable event
or if you are working the failing item list here. or if you are working the failing item list here.
Card type 57CF (embedded IOAs on DASD backplane Card type 57CF (embedded IOAs on DASD backplane
with 2BC2 dual battery charger and carrier card for the with 2BC2 dual battery charger and carrier card for the
embedded IOAs) read the following: When working embedded IOAs) read the following: When working
the FRUs from the serviceable event or the failing item the FRUs from the serviceable event or the failing item
list here, the embedded storage adapters (STORIOA) list here, the embedded storage adapters (STORIOA)
have two physical parts: have two physical parts:
v The embedded storage adapter on the DASD v The embedded storage adapter on the DASD
backplane. backplane.
v The dual battery charger and carrier card. To v The dual battery charger and carrier card. To
determine which battery is connected to which determine which battery is connected to which
embedded IOA use the bus number of the IOA with embedded IOA use the bus number of the IOA with
symbolic FRU CACHBAT. symbolic FRU CACHBAT.
See symbolic FRU FEATCRD for the location code of See symbolic FRU FEATCRD for the location code of
the dual battery charger and carrier card if it is not the dual battery charger and carrier card if it is not
listed in the serviceable event or if you are working the listed in the serviceable event or if you are working the
failing item list here. failing item list here.
Failing Item: Failing Item:
v SVCDOCS v STORIOA
v STORIOA v ANYBRDG
v PTFSRCH
572C8300 572C8300
Explanation: IOA hardware error or PCI bus error 572C8301 572C8301
Response: If you are working with one of the card Explanation: Not valid condition in Licensed Internal
types below, the adapter has mulitple physical parts. Code
Choose the card type to identify the physical parts of Response: If you are working with one of the card
the storage adapter. types below, the adapter has mulitple physical parts.
Card type 2BE1 (feature RAID enablement card for Choose the card type to identify the physical parts of
embedded IOA) read the following: When working the the storage adapter.
FRUs from the serviceable event or the failing item list Card type 2BE1 (feature RAID enablement card for
here, the embedded storage adapter (STORIOA) has embedded IOA) read the following: When working the
three physical parts: FRUs from the serviceable event or the failing item list
here, the embedded storage adapter (STORIOA) has FRUs from the serviceable event or the failing item list
three physical parts: here, the embedded storage adapter (STORIOA) has
v The embedded storage adapter on the I/O three physical parts:
backplane. v The embedded storage adapter on the I/O
v The RAID enablement card. backplane.
v The Battery charger and carrier card. v The RAID enablement card.
v The Battery charger and carrier card.
See symbolic FRU FEATCRD for the location codes of
the FRUs if they are not listed in the serviceable event See symbolic FRU FEATCRD for the location codes of
or if you are working the failing item list here. the FRUs if they are not listed in the serviceable event
or if you are working the failing item list here.
Card type 57CB (embedded IOA with 2BCF battery
card for embedded IOA) read the following: When Card type 57CB (embedded IOA with 2BCF battery
working the FRUs from the serviceable event or the card for embedded IOA) read the following: When
failing item list here, the embedded storage adapter working the FRUs from the serviceable event or the
(STORIOA) has two physical parts: failing item list here, the embedded storage adapter
v The embedded storage adapter on the I/O (STORIOA) has two physical parts:
backplane. v The embedded storage adapter on the I/O
v The Battery charger and carrier card. backplane.
v The Battery charger and carrier card.
See symbolic FRU FEATCRD for the location codes of
the FRUs if they are not listed in the serviceable event See symbolic FRU FEATCRD for the location codes of
or if you are working the failing item list here. the FRUs if they are not listed in the serviceable event
or if you are working the failing item list here.
Card type 57CF (embedded IOAs on DASD backplane
with 2BC2 dual battery charger and carrier card for the Card type 57CF (embedded IOAs on DASD backplane
embedded IOAs) read the following: When working with 2BC2 dual battery charger and carrier card for the
the FRUs from the serviceable event or the failing item embedded IOAs) read the following: When working
list here, the embedded storage adapters (STORIOA) the FRUs from the serviceable event or the failing item
have two physical parts: list here, the embedded storage adapters (STORIOA)
v The embedded storage adapter on the DASD have two physical parts:
backplane. v The embedded storage adapter on the DASD
v The dual battery charger and carrier card. To backplane.
determine which battery is connected to which v The dual battery charger and carrier card. To
embedded IOA use the bus number of the IOA with determine which battery is connected to which
symbolic FRU CACHBAT. embedded IOA use the bus number of the IOA with
symbolic FRU CACHBAT.
See symbolic FRU FEATCRD for the location code of
the dual battery charger and carrier card if it is not See symbolic FRU FEATCRD for the location code of
listed in the serviceable event or if you are working the the dual battery charger and carrier card if it is not
failing item list here. listed in the serviceable event or if you are working the
failing item list here.
Failing Item:
v PTFSRCH Failing Item:
v STORIOA v SVCDOCS
v STORIOA
572C8302 572C8302
572C8400 572C8400
Explanation: Missing Licensed Internal Code
Explanation: Licensed Internal Code error
Response: Ensure that the code necessary to support
this I/O adapter is loaded. Failing Item:
If you are working with one of the card types below, v PTFSRCH
the adapter has mulitple physical parts. Choose the
card type to identify the physical parts of the storage
adapter.
Card type 2BE1 (feature RAID enablement card for
embedded IOA) read the following: When working the
v FI01105
572C8404 572C8404
v STORIOA
Explanation: System log entry only. No service action
required.
572C9001 572C9001
See symbolic FRU FEATCRD for the location codes of Failing Item:
the FRUs if they are not listed in the serviceable event v NEXTLVL
or if you are working the failing item list here.
572C9020 572C9020
Card type 57CF (embedded IOAs on DASD backplane
with 2BC2 dual battery charger and carrier card for the Explanation: Two or more disk units missing from
embedded IOAs) read the following: When working RAID-5 or RAID-6 array
the FRUs from the serviceable event or the failing item
Failing Item:
list here, the embedded storage adapters (STORIOA)
have two physical parts: v SIP3111
v The embedded storage adapter on the DASD
backplane. 572C9021 572C9021
v The dual battery charger and carrier card. To Explanation: Two or more disk units missing from
determine which battery is connected to which RAID-5 or RAID-6 array
embedded IOA use the bus number of the IOA with
symbolic FRU CACHBAT. Failing Item:
v SIP3111
See symbolic FRU FEATCRD for the location code of
the dual battery charger and carrier card if it is not
listed in the serviceable event or if you are working the
failing item list here.
Failing Item:
Failing Item:
572C9031 572C9031
v SIP3110
v FI02112 Explanation: Automatic rebuild initiated for array
Response: Either a previous rebuild was interrupted
572C9026 572C9026 and was automatically restarted, or a hot spare disk
unit was used to automatically rebuild the array. Look
Explanation: Disk unit not found at required physical for other reference codes and take action on them.
location
Response: A previously exposed disk unit in an array 572C9032 572C9032
was not found at the required physical location.
Explanation: A disk unit in an array is missing or
Failing Item: failed
v NEXTLVL
Response: The array is still protected, but the disk
unit should be replaced.
572C9027 572C9027
Failing Item:
Explanation: Array not functional due to parity out of v SIP3110
synchronization
v FI02112
Response: Array is or would become exposed and
parity data is out of synchronization
572C9040 572C9040
Failing Item:
Explanation: Re-synchronization of array parity was
v SIP3113 initiated
Response: No action required.
v The embedded storage adapter on the I/O v The embedded storage adapter on the I/O
backplane. backplane.
v The RAID enablement card. v The RAID enablement card.
v The Battery charger and carrier card. v The Battery charger and carrier card.
See symbolic FRU FEATCRD for the location codes of See symbolic FRU FEATCRD for the location codes of
the FRUs if they are not listed in the serviceable event the FRUs if they are not listed in the serviceable event
or if you are working the failing item list here. or if you are working the failing item list here.
Card type 57CB (embedded IOA with 2BCF battery Card type 57CB (embedded IOA with 2BCF battery
card for embedded IOA) read the following: When card for embedded IOA) read the following: When
working the FRUs from the serviceable event or the working the FRUs from the serviceable event or the
failing item list here, the embedded storage adapter failing item list here, the embedded storage adapter
(STORIOA) has two physical parts: (STORIOA) has two physical parts:
v The embedded storage adapter on the I/O v The embedded storage adapter on the I/O
backplane. backplane.
v The Battery charger and carrier card. v The Battery charger and carrier card.
See symbolic FRU FEATCRD for the location codes of See symbolic FRU FEATCRD for the location codes of
the FRUs if they are not listed in the serviceable event the FRUs if they are not listed in the serviceable event
or if you are working the failing item list here. or if you are working the failing item list here.
Card type 57CF (embedded IOAs on DASD backplane Card type 57CF (embedded IOAs on DASD backplane
with 2BC2 dual battery charger and carrier card for the with 2BC2 dual battery charger and carrier card for the
embedded IOAs) read the following: When working embedded IOAs) read the following: When working
the FRUs from the serviceable event or the failing item the FRUs from the serviceable event or the failing item
list here, the embedded storage adapters (STORIOA) list here, the embedded storage adapters (STORIOA)
have two physical parts: have two physical parts:
v The embedded storage adapter on the DASD v The embedded storage adapter on the DASD
backplane. backplane.
v The dual battery charger and carrier card. To v The dual battery charger and carrier card. To
determine which battery is connected to which determine which battery is connected to which
embedded IOA use the bus number of the IOA with embedded IOA use the bus number of the IOA with
symbolic FRU CACHBAT. symbolic FRU CACHBAT.
See symbolic FRU FEATCRD for the location code of See symbolic FRU FEATCRD for the location code of
the dual battery charger and carrier card if it is not the dual battery charger and carrier card if it is not
listed in the serviceable event or if you are working the listed in the serviceable event or if you are working the
failing item list here. failing item list here.
Failing Item: Failing Item:
v FI01105 v FI01105
v STORIOA v STORIOA
If you cannot resolve the problem, contact your next Explanation: I/O adapter detected a recoverable error
level of support. Response: If you are working with one of the card
Failing Item: types below, the adapter has mulitple physical parts.
Choose the card type to identify the physical parts of
v SVCDOCS
the storage adapter.
Card type 2BE1 (feature RAID enablement card for
572C9091 572C9091
embedded IOA) read the following: When working the
Explanation: Incorrect hardware configuration change FRUs from the serviceable event or the failing item list
detected here, the embedded storage adapter (STORIOA) has
three physical parts:
Response: Use Hardware Service Manager to re-IPL
the virtual I/O processor that is associated with this v The embedded storage adapter on the I/O
I/O adapter. Other resources attached to the virtual backplane.
I/O processor may then need to be Varied On. v The RAID enablement card.
If any reference codes are surfaced, use the new v The Battery charger and carrier card.
reference code to resolve the problem.
See symbolic FRU FEATCRD for the location codes of
If you cannot resolve the problem, contact your next the FRUs if they are not listed in the serviceable event
level of support. or if you are working the failing item list here.
Failing Item:
Card type 57CB (embedded IOA with 2BCF battery
v SVCDOCS
card for embedded IOA) read the following: When
working the FRUs from the serviceable event or the
572C9092 572C9092 failing item list here, the embedded storage adapter
(STORIOA) has two physical parts:
Explanation: Disk unit requires initialization before
use. v The embedded storage adapter on the I/O
backplane.
Failing Item:
v The Battery charger and carrier card.
v SIP3134
See symbolic FRU FEATCRD for the location codes of
572C9500 572C9500 the FRUs if they are not listed in the serviceable event
or if you are working the failing item list here.
Explanation: Internal program error in driver code.
Failing Item: Card type 57CF (embedded IOAs on DASD backplane
with 2BC2 dual battery charger and carrier card for the
v PTFSRCH
embedded IOAs) read the following: When working
the FRUs from the serviceable event or the failing item
572C9903 572C9903 list here, the embedded storage adapters (STORIOA)
have two physical parts:
Explanation: Tape device information was logged.
Informational event, no service required. v The embedded storage adapter on the DASD
backplane.
v The dual battery charger and carrier card. To
572CC000 572CC000 determine which battery is connected to which
Explanation: System log entry only. No service action embedded IOA use the bus number of the IOA with
required. symbolic FRU CACHBAT.
v The embedded storage adapter on the I/O Card type 2BE1 (feature RAID enablement card for
backplane. embedded IOA) read the following: When working the
v The RAID enablement card. FRUs from the serviceable event or the failing item list
here, the embedded storage adapter (STORIOA) has
v The Battery charger and carrier card. three physical parts:
v The embedded storage adapter on the I/O
See symbolic FRU FEATCRD for the location codes of
backplane.
the FRUs if they are not listed in the serviceable event
or if you are working the failing item list here. v The RAID enablement card.
v The Battery charger and carrier card.
Card type 57CB (embedded IOA with 2BCF battery
card for embedded IOA) read the following: When See symbolic FRU FEATCRD for the location codes of
working the FRUs from the serviceable event or the the FRUs if they are not listed in the serviceable event
failing item list here, the embedded storage adapter or if you are working the failing item list here.
(STORIOA) has two physical parts:
Card type 57CB (embedded IOA with 2BCF battery v The RAID enablement card.
card for embedded IOA) read the following: When v The Battery charger and carrier card.
working the FRUs from the serviceable event or the
failing item list here, the embedded storage adapter See symbolic FRU FEATCRD for the location codes of
(STORIOA) has two physical parts: the FRUs if they are not listed in the serviceable event
v The embedded storage adapter on the I/O or if you are working the failing item list here.
backplane.
v The Battery charger and carrier card. Card type 57CB (embedded IOA with 2BCF battery
card) read the following: When working the FRUs from
See symbolic FRU FEATCRD for the location codes of the serviceable event or the failing item list here, the
the FRUs if they are not listed in the serviceable event embedded storage adapter (STORIOA) has two
or if you are working the failing item list here. physical parts:
v The embedded storage adapter on the I/O
Card type 57CF (embedded IOAs on DASD backplane backplane.
with 2BC2 dual battery charger and carrier card for the v The Battery charger and carrier card.
embedded IOAs) read the following: When working
the FRUs from the serviceable event or the failing item See symbolic FRU FEATCRD for the location codes of
list here, the embedded storage adapters (STORIOA) the FRUs if they are not listed in the serviceable event
have two physical parts: or if you are working the failing item list here.
v The embedded storage adapter on the DASD
backplane. Card type 57CF (embedded IOAs on DASD backplane
v The dual battery charger and carrier card. To with 2BC2 dual battery charger and carrier card) read
determine which battery is connected to which the following: When working the FRUs from the
embedded IOA use the bus number of the IOA with serviceable event or the failing item list here, the
symbolic FRU CACHBAT. embedded storage adapters (STORIOA) have two
physical parts:
See symbolic FRU FEATCRD for the location code of v The embedded storage adapter on the DASD
the dual battery charger and carrier card if it is not backplane.
listed in the serviceable event or if you are working the v The dual battery charger and carrier card. To
failing item list here. determine which battery is connected to which
Failing Item: embedded IOA use the bus number of the IOA with
symbolic FRU CACHBAT.
v BACKPLN
v STORIOA See symbolic FRU FEATCRD for the location code of
the dual battery charger and carrier card if it is not
572F8008 572F8008 listed in the serviceable event or if you are working the
failing item list here.
Explanation: A permanent cache battery pack failure
occurred Failing Item:
v CACHBAT
Response: Under a certain configuration, this SRC
may not represent an error that requires a service v STORIOA
action. Depending on the configuration of the system, v FEATCRD
the Storage IOA may have been altered and/or the
Storage IOA Cache may have been disabled to allow
attachment of OEM Storage that emulates a Load 572F8009 572F8009
Source drive. If this is the case, this error will be posted Explanation: Impending cache battery pack failure
each time the IOA is IPLed and it can be ignored.
Failing Item:
If you are working with one of the card types below,
v CACHBAT
the adapter has mulitple physical parts. Choose the
card type to identify the physical parts of the storage
adapter. 572F8100 572F8100
Card type 2BE1 (feature RAID enablement card for Explanation: Licensed Internal Code error
embedded IOA) read the following: When working the
Response: If you are working with one of the card
FRUs from the serviceable event or the failing item list
types below, the adapter has mulitple physical parts.
here, the embedded storage adapter (STORIOA) has
Choose the card type to identify the physical parts of
three physical parts:
the storage adapter.
v The embedded storage adapter on the I/O
backplane. Card type 2BE1 (feature RAID enablement card for
Card type 57CB (embedded IOA with 2BCF battery Card type 57CB (embedded IOA with 2BCF battery
card for embedded IOA) read the following: When card for embedded IOA) read the following: When
working the FRUs from the serviceable event or the working the FRUs from the serviceable event or the
failing item list here, the embedded storage adapter failing item list here, the embedded storage adapter
(STORIOA) has two physical parts: (STORIOA) has two physical parts:
v The embedded storage adapter on the I/O v The embedded storage adapter on the I/O
backplane. backplane.
v The Battery charger and carrier card. v The Battery charger and carrier card.
See symbolic FRU FEATCRD for the location codes of See symbolic FRU FEATCRD for the location codes of
the FRUs if they are not listed in the serviceable event the FRUs if they are not listed in the serviceable event
or if you are working the failing item list here. or if you are working the failing item list here.
Card type 57CF (embedded IOAs on DASD backplane Card type 57CF (embedded IOAs on DASD backplane
with 2BC2 dual battery charger and carrier card for the with 2BC2 dual battery charger and carrier card for the
embedded IOAs) read the following: When working embedded IOAs) read the following: When working
the FRUs from the serviceable event or the failing item the FRUs from the serviceable event or the failing item
list here, the embedded storage adapters (STORIOA) list here, the embedded storage adapters (STORIOA)
have two physical parts: have two physical parts:
v The embedded storage adapter on the DASD v The embedded storage adapter on the DASD
backplane. backplane.
v The dual battery charger and carrier card. To v The dual battery charger and carrier card. To
determine which battery is connected to which determine which battery is connected to which
embedded IOA use the bus number of the IOA with embedded IOA use the bus number of the IOA with
symbolic FRU CACHBAT. symbolic FRU CACHBAT.
See symbolic FRU FEATCRD for the location code of See symbolic FRU FEATCRD for the location code of
the dual battery charger and carrier card if it is not the dual battery charger and carrier card if it is not
listed in the serviceable event or if you are working the listed in the serviceable event or if you are working the
failing item list here. failing item list here.
Failing Item: Failing Item:
v STORIOA v PTFSRCH
v ANYBRDG v STORIOA
See symbolic FRU FEATCRD for the location codes of See symbolic FRU FEATCRD for the location codes of
the FRUs if they are not listed in the serviceable event the FRUs if they are not listed in the serviceable event
or if you are working the failing item list here. or if you are working the failing item list here.
Card type 57CB (embedded IOA with 2BCF battery Card type 57CB (embedded IOA with 2BCF battery
card for embedded IOA) read the following: When card for embedded IOA) read the following: When
working the FRUs from the serviceable event or the working the FRUs from the serviceable event or the
failing item list here, the embedded storage adapter failing item list here, the embedded storage adapter
(STORIOA) has two physical parts: (STORIOA) has two physical parts:
v The embedded storage adapter on the I/O v The embedded storage adapter on the I/O
backplane. backplane.
v The Battery charger and carrier card. v The Battery charger and carrier card.
See symbolic FRU FEATCRD for the location codes of See symbolic FRU FEATCRD for the location codes of
the FRUs if they are not listed in the serviceable event the FRUs if they are not listed in the serviceable event
or if you are working the failing item list here. or if you are working the failing item list here.
Card type 57CF (embedded IOAs on DASD backplane Card type 57CF (embedded IOAs on DASD backplane
with 2BC2 dual battery charger and carrier card for the with 2BC2 dual battery charger and carrier card for the
embedded IOAs) read the following: When working embedded IOAs) read the following: When working
the FRUs from the serviceable event or the failing item the FRUs from the serviceable event or the failing item
list here, the embedded storage adapters (STORIOA) list here, the embedded storage adapters (STORIOA)
have two physical parts: have two physical parts:
v The embedded storage adapter on the DASD v The embedded storage adapter on the DASD
backplane. backplane.
v The dual battery charger and carrier card. To v The dual battery charger and carrier card. To
determine which battery is connected to which determine which battery is connected to which
embedded IOA use the bus number of the IOA with embedded IOA use the bus number of the IOA with
symbolic FRU CACHBAT. symbolic FRU CACHBAT.
See symbolic FRU FEATCRD for the location code of See symbolic FRU FEATCRD for the location code of
the dual battery charger and carrier card if it is not the dual battery charger and carrier card if it is not
listed in the serviceable event or if you are working the listed in the serviceable event or if you are working the
failing item list here. failing item list here.
Failing Item: Failing Item:
v PTFSRCH v PTFSRCH
v STORIOA v STORIOA
v The embedded storage adapter on the I/O v The embedded storage adapter on the I/O
backplane. backplane.
v The RAID enablement card. v The RAID enablement card.
v The Battery charger and carrier card. v The Battery charger and carrier card.
See symbolic FRU FEATCRD for the location codes of See symbolic FRU FEATCRD for the location codes of
the FRUs if they are not listed in the serviceable event the FRUs if they are not listed in the serviceable event
or if you are working the failing item list here. or if you are working the failing item list here.
Card type 57CB (embedded IOA with 2BCF battery Card type 57CB (embedded IOA with 2BCF battery
card for embedded IOA) read the following: When card for embedded IOA) read the following: When
working the FRUs from the serviceable event or the working the FRUs from the serviceable event or the
failing item list here, the embedded storage adapter failing item list here, the embedded storage adapter
(STORIOA) has two physical parts: (STORIOA) has two physical parts:
v The embedded storage adapter on the I/O v The embedded storage adapter on the I/O
backplane. backplane.
v The Battery charger and carrier card. v The Battery charger and carrier card.
See symbolic FRU FEATCRD for the location codes of See symbolic FRU FEATCRD for the location codes of
the FRUs if they are not listed in the serviceable event the FRUs if they are not listed in the serviceable event
or if you are working the failing item list here. or if you are working the failing item list here.
Card type 57CF (embedded IOAs on DASD backplane Card type 57CF (embedded IOAs on DASD backplane
with 2BC2 dual battery charger and carrier card for the with 2BC2 dual battery charger and carrier card for the
embedded IOAs) read the following: When working embedded IOAs) read the following: When working
the FRUs from the serviceable event or the failing item the FRUs from the serviceable event or the failing item
list here, the embedded storage adapters (STORIOA) list here, the embedded storage adapters (STORIOA)
have two physical parts: have two physical parts:
v The embedded storage adapter on the DASD v The embedded storage adapter on the DASD
backplane. backplane.
v The dual battery charger and carrier card. To v The dual battery charger and carrier card. To
determine which battery is connected to which determine which battery is connected to which
embedded IOA use the bus number of the IOA with embedded IOA use the bus number of the IOA with
symbolic FRU CACHBAT. symbolic FRU CACHBAT.
See symbolic FRU FEATCRD for the location code of See symbolic FRU FEATCRD for the location code of
the dual battery charger and carrier card if it is not the dual battery charger and carrier card if it is not
listed in the serviceable event or if you are working the listed in the serviceable event or if you are working the
failing item list here. failing item list here.
Failing Item: Failing Item:
v SVCDOCS v STORIOA
v STORIOA v ANYBRDG
v PTFSRCH
572F8300 572F8300
Explanation: IOA hardware error or PCI bus error 572F8301 572F8301
Response: If you are working with one of the card Explanation: Not valid condition in Licensed Internal
types below, the adapter has mulitple physical parts. Code
Choose the card type to identify the physical parts of Response: If you are working with one of the card
the storage adapter. types below, the adapter has mulitple physical parts.
Card type 2BE1 (feature RAID enablement card for Choose the card type to identify the physical parts of
embedded IOA) read the following: When working the the storage adapter.
FRUs from the serviceable event or the failing item list Card type 2BE1 (feature RAID enablement card for
here, the embedded storage adapter (STORIOA) has embedded IOA) read the following: When working the
three physical parts: FRUs from the serviceable event or the failing item list
here, the embedded storage adapter (STORIOA) has FRUs from the serviceable event or the failing item list
three physical parts: here, the embedded storage adapter (STORIOA) has
v The embedded storage adapter on the I/O three physical parts:
backplane. v The embedded storage adapter on the I/O
v The RAID enablement card. backplane.
v The Battery charger and carrier card. v The RAID enablement card.
v The Battery charger and carrier card.
See symbolic FRU FEATCRD for the location codes of
the FRUs if they are not listed in the serviceable event See symbolic FRU FEATCRD for the location codes of
or if you are working the failing item list here. the FRUs if they are not listed in the serviceable event
or if you are working the failing item list here.
Card type 57CB (embedded IOA with 2BCF battery
card for embedded IOA) read the following: When Card type 57CB (embedded IOA with 2BCF battery
working the FRUs from the serviceable event or the card for embedded IOA) read the following: When
failing item list here, the embedded storage adapter working the FRUs from the serviceable event or the
(STORIOA) has two physical parts: failing item list here, the embedded storage adapter
v The embedded storage adapter on the I/O (STORIOA) has two physical parts:
backplane. v The embedded storage adapter on the I/O
v The Battery charger and carrier card. backplane.
v The Battery charger and carrier card.
See symbolic FRU FEATCRD for the location codes of
the FRUs if they are not listed in the serviceable event See symbolic FRU FEATCRD for the location codes of
or if you are working the failing item list here. the FRUs if they are not listed in the serviceable event
or if you are working the failing item list here.
Card type 57CF (embedded IOAs on DASD backplane
with 2BC2 dual battery charger and carrier card for the Card type 57CF (embedded IOAs on DASD backplane
embedded IOAs) read the following: When working with 2BC2 dual battery charger and carrier card for the
the FRUs from the serviceable event or the failing item embedded IOAs) read the following: When working
list here, the embedded storage adapters (STORIOA) the FRUs from the serviceable event or the failing item
have two physical parts: list here, the embedded storage adapters (STORIOA)
v The embedded storage adapter on the DASD have two physical parts:
backplane. v The embedded storage adapter on the DASD
v The dual battery charger and carrier card. To backplane.
determine which battery is connected to which v The dual battery charger and carrier card. To
embedded IOA use the bus number of the IOA with determine which battery is connected to which
symbolic FRU CACHBAT. embedded IOA use the bus number of the IOA with
symbolic FRU CACHBAT.
See symbolic FRU FEATCRD for the location code of
the dual battery charger and carrier card if it is not See symbolic FRU FEATCRD for the location code of
listed in the serviceable event or if you are working the the dual battery charger and carrier card if it is not
failing item list here. listed in the serviceable event or if you are working the
failing item list here.
Failing Item:
v PTFSRCH Failing Item:
v STORIOA v SVCDOCS
v STORIOA
572F8302 572F8302
572F8400 572F8400
Explanation: Missing Licensed Internal Code
Explanation: Licensed Internal Code error
Response: Ensure that the code necessary to support
this I/O adapter is loaded. Failing Item:
If you are working with one of the card types below, v PTFSRCH
the adapter has mulitple physical parts. Choose the
card type to identify the physical parts of the storage
adapter.
Card type 2BE1 (feature RAID enablement card for
embedded IOA) read the following: When working the
v FI01105
572F8404 572F8404
v STORIOA
Explanation: System log entry only. No service action
required.
572F9001 572F9001
See symbolic FRU FEATCRD for the location codes of Failing Item:
the FRUs if they are not listed in the serviceable event v NEXTLVL
or if you are working the failing item list here.
572F9020 572F9020
Card type 57CF (embedded IOAs on DASD backplane
with 2BC2 dual battery charger and carrier card for the Explanation: Two or more disk units missing from
embedded IOAs) read the following: When working RAID-5 or RAID-6 array
the FRUs from the serviceable event or the failing item
Failing Item:
list here, the embedded storage adapters (STORIOA)
have two physical parts: v SIP3111
v The embedded storage adapter on the DASD
backplane. 572F9021 572F9021
v The dual battery charger and carrier card. To Explanation: Two or more disk units missing from
determine which battery is connected to which RAID-5 or RAID-6 array
embedded IOA use the bus number of the IOA with
symbolic FRU CACHBAT. Failing Item:
v SIP3111
See symbolic FRU FEATCRD for the location code of
the dual battery charger and carrier card if it is not
listed in the serviceable event or if you are working the
failing item list here.
Failing Item:
Failing Item:
572F9031 572F9031
v SIP3110
v FI02112 Explanation: Automatic rebuild initiated for array
Response: Either a previous rebuild was interrupted
572F9026 572F9026 and was automatically restarted, or a hot spare disk
unit was used to automatically rebuild the array. Look
Explanation: Disk unit not found at required physical for other reference codes and take action on them.
location
Response: A previously exposed disk unit in an array 572F9032 572F9032
was not found at the required physical location.
Explanation: A disk unit in an array is missing or
Failing Item: failed
v NEXTLVL
Response: The array is still protected, but the disk
unit should be replaced.
572F9027 572F9027
Failing Item:
Explanation: Array not functional due to parity out of v SIP3110
synchronization
v FI02112
Response: Array is or would become exposed and
parity data is out of synchronization
572F9040 572F9040
Failing Item:
Explanation: Re-synchronization of array parity was
v SIP3113 initiated
Response: No action required.
v The embedded storage adapter on the I/O v The embedded storage adapter on the I/O
backplane. backplane.
v The RAID enablement card. v The RAID enablement card.
v The Battery charger and carrier card. v The Battery charger and carrier card.
See symbolic FRU FEATCRD for the location codes of See symbolic FRU FEATCRD for the location codes of
the FRUs if they are not listed in the serviceable event the FRUs if they are not listed in the serviceable event
or if you are working the failing item list here. or if you are working the failing item list here.
Card type 57CB (embedded IOA with 2BCF battery Card type 57CB (embedded IOA with 2BCF battery
card for embedded IOA) read the following: When card for embedded IOA) read the following: When
working the FRUs from the serviceable event or the working the FRUs from the serviceable event or the
failing item list here, the embedded storage adapter failing item list here, the embedded storage adapter
(STORIOA) has two physical parts: (STORIOA) has two physical parts:
v The embedded storage adapter on the I/O v The embedded storage adapter on the I/O
backplane. backplane.
v The Battery charger and carrier card. v The Battery charger and carrier card.
See symbolic FRU FEATCRD for the location codes of See symbolic FRU FEATCRD for the location codes of
the FRUs if they are not listed in the serviceable event the FRUs if they are not listed in the serviceable event
or if you are working the failing item list here. or if you are working the failing item list here.
Card type 57CF (embedded IOAs on DASD backplane Card type 57CF (embedded IOAs on DASD backplane
with 2BC2 dual battery charger and carrier card for the with 2BC2 dual battery charger and carrier card for the
embedded IOAs) read the following: When working embedded IOAs) read the following: When working
the FRUs from the serviceable event or the failing item the FRUs from the serviceable event or the failing item
list here, the embedded storage adapters (STORIOA) list here, the embedded storage adapters (STORIOA)
have two physical parts: have two physical parts:
v The embedded storage adapter on the DASD v The embedded storage adapter on the DASD
backplane. backplane.
v The dual battery charger and carrier card. To v The dual battery charger and carrier card. To
determine which battery is connected to which determine which battery is connected to which
embedded IOA use the bus number of the IOA with embedded IOA use the bus number of the IOA with
symbolic FRU CACHBAT. symbolic FRU CACHBAT.
See symbolic FRU FEATCRD for the location code of See symbolic FRU FEATCRD for the location code of
the dual battery charger and carrier card if it is not the dual battery charger and carrier card if it is not
listed in the serviceable event or if you are working the listed in the serviceable event or if you are working the
failing item list here. failing item list here.
Failing Item: Failing Item:
v FI01105 v FI01105
v STORIOA v STORIOA
If you cannot resolve the problem, contact your next Explanation: I/O adapter detected a recoverable error
level of support. Response: If you are working with one of the card
Failing Item: types below, the adapter has mulitple physical parts.
Choose the card type to identify the physical parts of
v SVCDOCS
the storage adapter.
Card type 2BE1 (feature RAID enablement card for
572F9091 572F9091
embedded IOA) read the following: When working the
Explanation: Incorrect hardware configuration change FRUs from the serviceable event or the failing item list
detected here, the embedded storage adapter (STORIOA) has
three physical parts:
Response: Use Hardware Service Manager to re-IPL
the virtual I/O processor that is associated with this v The embedded storage adapter on the I/O
I/O adapter. Other resources attached to the virtual backplane.
I/O processor may then need to be Varied On. v The RAID enablement card.
If any reference codes are surfaced, use the new v The Battery charger and carrier card.
reference code to resolve the problem.
See symbolic FRU FEATCRD for the location codes of
If you cannot resolve the problem, contact your next the FRUs if they are not listed in the serviceable event
level of support. or if you are working the failing item list here.
Failing Item:
Card type 57CB (embedded IOA with 2BCF battery
v SVCDOCS
card for embedded IOA) read the following: When
working the FRUs from the serviceable event or the
572F9092 572F9092 failing item list here, the embedded storage adapter
(STORIOA) has two physical parts:
Explanation: Disk unit requires initialization before
use. v The embedded storage adapter on the I/O
backplane.
Failing Item:
v The Battery charger and carrier card.
v SIP3134
See symbolic FRU FEATCRD for the location codes of
572F9500 572F9500 the FRUs if they are not listed in the serviceable event
or if you are working the failing item list here.
Explanation: Internal program error in driver code.
Failing Item: Card type 57CF (embedded IOAs on DASD backplane
with 2BC2 dual battery charger and carrier card for the
v PTFSRCH
embedded IOAs) read the following: When working
the FRUs from the serviceable event or the failing item
572F9903 572F9903 list here, the embedded storage adapters (STORIOA)
have two physical parts:
Explanation: Tape device information was logged.
Informational event, no service required. v The embedded storage adapter on the DASD
backplane.
v The dual battery charger and carrier card. To
572FC000 572FC000 determine which battery is connected to which
Explanation: System log entry only. No service action embedded IOA use the bus number of the IOA with
required. symbolic FRU CACHBAT.
573AB9B0 573AB9B0
Explanation: I/O adapter hardware error detected
Failing Item:
v IOA
v AJDG301
573BA6E3 573BA6E3
Explanation: Ethernet adapter or network device
cabling error.
Failing Item:
v FI00722
v UJE40
v IOA
573BB100 573BB100
Explanation: I/O adapter hardware error detected
Failing Item:
v IOA
v AJDG301
573BB200 573BB200
Explanation: I/O adapter hardware error detected
Failing Item:
v AJDG301
v IOA
573BB300 573BB300
Explanation: An I/O adapter hardware error was
detected.
Response: Work the Failing Item list from the
serviceable event view if it is available, otherwise use
this Failing Item list.
Problem determination: Varying off and then varying
on the resource may resolve the problem. If that does
not resolve the problem then have the service provider
work the problem.
Failing Item:
v IOA
v AJDG301
573CA6E3 573CA6E3
Explanation: Ethernet adapter or network device
cabling error.
Failing Item:
v FI00722
v UJE40
v IOA
573CB100 573CB100
Explanation: I/O adapter hardware error detected
Failing Item:
v IOA
v AJDG301
573CB200 573CB200
Explanation: I/O adapter hardware error detected
Failing Item:
v AJDG301
v IOA
573CB300 573CB300
Explanation: I/O adapter hardware error detected
Failing Item:
v IOA
v AJDG301
v STORIOA
573D3140 573D3140
v FI01140
Explanation: Bus is operational
v DEVBPLN
Response: This reference code and the 3120 reference
code that occurred before it require no service action
573D3103 573D3103
because SCSI bus 0 is now operational.
Explanation: Interface error
Response: Error occurred on SCSI bus 3. 573D3141 573D3141
v FI01140
v DEVBPLN 573D3142 573D3142
Explanation: Bus is operational
573D3120 573D3120 Response: This reference code and the 3122 reference
Explanation: Bus is not operational code that occurred before it require no service action
because SCSI bus 2 is now operational.
Response: Adding a device to SCSI bus 0 of the I/O
Adapter caused the bus to become not operational.
Remove the device. 573D3143 573D3143
Response: NOTE: If external devices are attached Explanation: System log entry only. No service action
check EXTSCSI and DEVTERM first. required.
Failing Item:
573D4150 573D4150
v FI02112
v STORIOA Explanation: I/O adapter detected PCI bus error
v FI01106 Response: If this event appears in a serviceable event
v FI01140 view, work with the failing item list found there. If this
event does not appear in a serviceable event view, no
service action is required.
573D3401 573D3401
If you are working with one of the card types below,
Explanation: Device backplane problem the adapter has mulitple physical parts. Choose the
Failing Item: card type to identify the physical parts of the storage
adapter.
v DEVBPLN
Card type 2BE1 (feature RAID enablement card for
embedded IOA) read the following: When working the
573D3405 573D3405 FRUs from the serviceable event or the failing item list
Explanation: An error occurred during task here, the embedded storage adapter (STORIOA) has
initialization for a removable media device. This SRC is three physical parts:
logged when an error occurs and the removable media v The embedded storage adapter on the I/O
device driver cannot determine the device type or backplane.
model. v The RAID enablement card.
Response: Perform the following: v The Battery charger and carrier card.
v Check the Product Activity Log for other entries that
indicate interface problems and work those See symbolic FRU FEATCRD for the location codes of
problems. the FRUs if they are not listed in the serviceable event
v Check the device firmware level and apply the latest or if you are working the failing item list here.
PTFs.
Card type 57CB (embedded IOA with 2BCF battery
v Check for LIC logs with major code 2E00. Contact
card for embedded IOA) read the following: When
your next level of support with the information you
working the FRUs from the serviceable event or the
have gathered.
failing item list here, the embedded storage adapter
Problem determination: IPL the IOP to retry the (STORIOA) has two physical parts:
device identification process. If the error persists then v The embedded storage adapter on the I/O
contact your service provider. backplane.
Failing Item: v The Battery charger and carrier card.
v PTFSRCH
See symbolic FRU FEATCRD for the location codes of
the FRUs if they are not listed in the serviceable event
573D34FF 573D34FF or if you are working the failing item list here.
Explanation: A device on this adapter is being
formatted. Wait for the formatting to complete. Card type 57CF (embedded IOAs on DASD backplane
with 2BC2 dual battery charger and carrier card for the
Failing Item: embedded IOAs) read the following: When working
v SVCDOCS
the FRUs from the serviceable event or the failing item Card type 57CF (embedded IOAs on DASD backplane
list here, the embedded storage adapters (STORIOA) with 2BC2 dual battery charger and carrier card for the
have two physical parts: embedded IOAs) read the following: When working
v The embedded storage adapter on the DASD the FRUs from the serviceable event or the failing item
backplane. list here, the embedded storage adapters (STORIOA)
have two physical parts:
v The dual battery charger and carrier card. To
determine which battery is connected to which v The embedded storage adapter on the DASD
embedded IOA use the bus number of the IOA with backplane.
symbolic FRU CACHBAT. v The dual battery charger and carrier card. To
determine which battery is connected to which
See symbolic FRU FEATCRD for the location code of embedded IOA use the bus number of the IOA with
the dual battery charger and carrier card if it is not symbolic FRU CACHBAT.
listed in the serviceable event or if you are working the
failing item list here. See symbolic FRU FEATCRD for the location code of
the dual battery charger and carrier card if it is not
Failing Item:
listed in the serviceable event or if you are working the
v BACKPLN failing item list here.
v STORIOA
Failing Item:
v BACKPLN
573D4160 573D4160
v STORIOA
Explanation: I/O adapter detected and recovered a
PCI bus error
573D8008 573D8008
Response: If this event appears in a serviceable event
Explanation: A permanent cache battery pack failure
view, work with the failing item list found there. If this
occurred
event does not appear in a serviceable event view, no
service action is required. Response: NOTE: Under a certain configuration, this
SRC may not represent an error that requires a service
If you are working with one of the card types below,
action. Depending on the configuration of the system,
the adapter has mulitple physical parts. Choose the
the Storage IOA may have been altered and/or the
card type to identify the physical parts of the storage
Storage IOA Cache may have been disabled to allow
adapter.
attachment of OEM Storage that emulates a Load
Card type 2BE1 (feature RAID enablement card for Source drive. If this is the case, this error will be posted
embedded IOA) read the following: When working the each time the IOA is IPLed and it can be ignored.
FRUs from the serviceable event or the failing item list
Failing Item:
here, the embedded storage adapter (STORIOA) has
three physical parts: v CACHBAT
v The embedded storage adapter on the I/O v STORIOA
backplane.
v The RAID enablement card. 573D8009 573D8009
v The Battery charger and carrier card. Explanation: Impending cache battery pack failure
See symbolic FRU FEATCRD for the location codes of Failing Item:
the FRUs if they are not listed in the serviceable event v CACHBAT
or if you are working the failing item list here.
573D8100 573D8100
Card type 57CB (embedded IOA with 2BCF battery
card for embedded IOA) read the following: When Explanation: Licensed Internal Code error
working the FRUs from the serviceable event or the
Failing Item:
failing item list here, the embedded storage adapter
(STORIOA) has two physical parts: v PTFSRCH
v The embedded storage adapter on the I/O v STORIOA
backplane.
v The Battery charger and carrier card. 573D8130 573D8130
Explanation: IOA detected recoverable device bus
See symbolic FRU FEATCRD for the location codes of
error
the FRUs if they are not listed in the serviceable event
or if you are working the failing item list here. Response: An error occurred on SCSI bus 0. No action
v SVCDOCS
573D9002 573D9002
Explanation: Device error
573D8300 573D8300
Response:
Explanation: IOA hardware error or PCI bus error
Failing Item:
Failing Item:
v IOPIP16
v STORIOA
v FI01105
v ANYBRDG
v STORIOA
v PTFSRCH
v FI01140
v BACKPLN
573D8301 573D8301
v FI01106
Explanation: Not valid condition in Licensed Internal
Code
573D9008 573D9008
Failing Item:
Explanation: I/O card does not support functions
v PTFSRCH
expected by devices
v STORIOA
Response:
573D8400 573D8400
573D9010 573D9010
Explanation: Licensed Internal Code error
Explanation: Cache data associated with attached
Failing Item: devices cannot be found
v PTFSRCH
Response:
Failing Item:
573D8404 573D8404
v IOPIP31
Explanation: System log entry only. No service action
required.
573D9011 573D9011
573D9020 573D9020
573D9001 573D9001
Explanation: Array not functional due to present
Explanation: Device configuration error
hardware configuration.
Response:
Response:
Failing Item:
Failing Item:
v IOPIP33
v IOPIP20
573D9040 573D9040
573D9053 573D9053
Explanation: Array protection temporarily suspended
Explanation: IOA resources not available due to
Response: No action required. Protection will be previous problems
automatically restarted.
Response: Take action on other reference codes which
have surfaced.
573D9041 573D9041
If you cannot get to SST or DST, and cannot perform a
Explanation: Background array parity check detected type A or B IPL, perform a type D IPL from removable
and corrected errors media. Look for Product Activity Log entries for other
reference codes and take action on them.
Response: Call your next level of support to report
the problem. Failing Item:
Failing Item: v SVCDOCS
v PTFSRCH
573D9054 573D9054
573D9042 573D9042 Explanation: IOA resources not available due to
previous problems
Explanation: An array parity error has been detected
and corrected Response: Power off the system and remove all new
or replacement disk units. IPL the system to DST. If
Response: Call your next level of support to report
you cannot perform a type A or B IPL, perform a type
the problem.
D IPL from removable media.
Failing Item:
Look for Product Activity Log entries for other
v NEXTLVL reference codes and take action on them.
Failing Item:
573D9050 573D9050
v SVCDOCS
Explanation: Required cache data cannot be located
for a disk unit.
573D9071 573D9071
Response:
Explanation: Link from IOA to auxiliary cache IOA
Failing Item: went operational
v IOPIP30 Response: No service action required.
Response:
573D9903 573D9903
Failing Item:
Explanation: Tape device information was logged.
v IOPIP16
Informational event, no service required.
v FI01105
v STORIOA
573DC000 573DC000
v FI01140
Explanation: System log entry only. No service action
v BACKPLN
required.
v FI01106
Response: No action is required. This reference code
is logged for information only.
573D9090 573D9090
Explanation: Disk unit has been modified after the 573DC100 573DC100
last known status.
Explanation: System log entry only. No service action
Response: Re-IPL the system. If any reference codes required.
are surfaced, use the new reference code to resolve the
problem. Response: No action is required. This reference code
is logged for information only.
If you cannot resolve the problem, contact your next
level of support.
573DC402 573DC402
Failing Item:
Explanation: Licensed Internal Code error
v SVCDOCS
Response: Ask your next level of support for
assistance.
573D9091 573D9091
Failing Item:
Explanation: Incorrect hardware configuration change
detected v PTFSRCH
573DFF6D 573DFF6D
Explanation: Recoverable system bus error
Failing Item:
v STORIOA
v ANYBRDG
v PTFSRCH
v STORIOA
573E3140 573E3140
v FI01140
Explanation: Bus is operational
v DEVBPLN
Response: This reference code and the 3120 reference
code that occurred before it require no service action
573E3103 573E3103
because SCSI bus 0 is now operational.
Explanation: Interface error
Response: Error occurred on SCSI bus 3. 573E3141 573E3141
v FI01140
v DEVBPLN 573E3142 573E3142
Explanation: Bus is operational
573E3120 573E3120 Response: This reference code and the 3122 reference
Explanation: Bus is not operational code that occurred before it require no service action
because SCSI bus 2 is now operational.
Response: Adding a device to SCSI bus 0 of the I/O
Adapter caused the bus to become not operational.
Remove the device. 573E3143 573E3143
Response: NOTE: If external devices are attached Explanation: System log entry only. No service action
check EXTSCSI and DEVTERM first. required.
Failing Item:
573E4150 573E4150
v FI02112
v STORIOA Explanation: I/O adapter detected PCI bus error
v FI01106 Response: If this event appears in a serviceable event
v FI01140 view, work with the failing item list found there. If this
event does not appear in a serviceable event view, no
service action is required.
573E3401 573E3401
If you are working with one of the card types below,
Explanation: Device backplane problem the adapter has mulitple physical parts. Choose the
Failing Item: card type to identify the physical parts of the storage
adapter.
v DEVBPLN
Card type 2BE1 (feature RAID enablement card for
embedded IOA) read the following: When working the
573E3405 573E3405 FRUs from the serviceable event or the failing item list
Explanation: An error occurred during task here, the embedded storage adapter (STORIOA) has
initialization for a removable media device. This SRC is three physical parts:
logged when an error occurs and the removable media v The embedded storage adapter on the I/O
device driver cannot determine the device type or backplane.
model. v The RAID enablement card.
Response: Perform the following: v The Battery charger and carrier card.
v Check the Product Activity Log for other entries that
indicate interface problems and work those See symbolic FRU FEATCRD for the location codes of
problems. the FRUs if they are not listed in the serviceable event
v Check the device firmware level and apply the latest or if you are working the failing item list here.
PTFs.
Card type 57CB (embedded IOA with 2BCF battery
v Check for LIC logs with major code 2E00. Contact
card for embedded IOA) read the following: When
your next level of support with the information you
working the FRUs from the serviceable event or the
have gathered.
failing item list here, the embedded storage adapter
Problem determination: IPL the IOP to retry the (STORIOA) has two physical parts:
device identification process. If the error persists then v The embedded storage adapter on the I/O
contact your service provider. backplane.
Failing Item: v The Battery charger and carrier card.
v PTFSRCH
See symbolic FRU FEATCRD for the location codes of
the FRUs if they are not listed in the serviceable event
573E34FF 573E34FF or if you are working the failing item list here.
Explanation: A device on this adapter is being
formatted. Wait for the formatting to complete. Card type 57CF (embedded IOAs on DASD backplane
with 2BC2 dual battery charger and carrier card for the
Failing Item: embedded IOAs) read the following: When working
v SVCDOCS
the FRUs from the serviceable event or the failing item Card type 57CF (embedded IOAs on DASD backplane
list here, the embedded storage adapters (STORIOA) with 2BC2 dual battery charger and carrier card for the
have two physical parts: embedded IOAs) read the following: When working
v The embedded storage adapter on the DASD the FRUs from the serviceable event or the failing item
backplane. list here, the embedded storage adapters (STORIOA)
have two physical parts:
v The dual battery charger and carrier card. To
determine which battery is connected to which v The embedded storage adapter on the DASD
embedded IOA use the bus number of the IOA with backplane.
symbolic FRU CACHBAT. v The dual battery charger and carrier card. To
determine which battery is connected to which
See symbolic FRU FEATCRD for the location code of embedded IOA use the bus number of the IOA with
the dual battery charger and carrier card if it is not symbolic FRU CACHBAT.
listed in the serviceable event or if you are working the
failing item list here. See symbolic FRU FEATCRD for the location code of
the dual battery charger and carrier card if it is not
Failing Item:
listed in the serviceable event or if you are working the
v BACKPLN failing item list here.
v STORIOA
Failing Item:
v BACKPLN
573E4160 573E4160
v STORIOA
Explanation: I/O adapter detected and recovered a
PCI bus error
573E8008 573E8008
Response: If this event appears in a serviceable event
Explanation: A permanent cache battery pack failure
view, work with the failing item list found there. If this
occurred
event does not appear in a serviceable event view, no
service action is required. Response: NOTE: Under a certain configuration, this
SRC may not represent an error that requires a service
If you are working with one of the card types below,
action. Depending on the configuration of the system,
the adapter has mulitple physical parts. Choose the
the Storage IOA may have been altered and/or the
card type to identify the physical parts of the storage
Storage IOA Cache may have been disabled to allow
adapter.
attachment of OEM Storage that emulates a Load
Card type 2BE1 (feature RAID enablement card for Source drive. If this is the case, this error will be posted
embedded IOA) read the following: When working the each time the IOA is IPLed and it can be ignored.
FRUs from the serviceable event or the failing item list
Failing Item:
here, the embedded storage adapter (STORIOA) has
three physical parts: v CACHBAT
v The embedded storage adapter on the I/O v STORIOA
backplane.
v The RAID enablement card. 573E8009 573E8009
v The Battery charger and carrier card. Explanation: Impending cache battery pack failure
See symbolic FRU FEATCRD for the location codes of Failing Item:
the FRUs if they are not listed in the serviceable event v CACHBAT
or if you are working the failing item list here.
573E8100 573E8100
Card type 57CB (embedded IOA with 2BCF battery
card for embedded IOA) read the following: When Explanation: Licensed Internal Code error
working the FRUs from the serviceable event or the
Failing Item:
failing item list here, the embedded storage adapter
(STORIOA) has two physical parts: v PTFSRCH
v The embedded storage adapter on the I/O v STORIOA
backplane.
v The Battery charger and carrier card. 573E8130 573E8130
Explanation: IOA detected recoverable device bus
See symbolic FRU FEATCRD for the location codes of
error
the FRUs if they are not listed in the serviceable event
or if you are working the failing item list here. Response: An error occurred on SCSI bus 0. No action
v SVCDOCS
573E9002 573E9002
Explanation: Device error
573E8300 573E8300
Response:
Explanation: IOA hardware error or PCI bus error
Failing Item:
Failing Item:
v IOPIP16
v STORIOA
v FI01105
v ANYBRDG
v STORIOA
v PTFSRCH
v FI01140
v BACKPLN
573E8301 573E8301
v FI01106
Explanation: Not valid condition in Licensed Internal
Code
573E9008 573E9008
Failing Item:
Explanation: I/O card does not support functions
v PTFSRCH
expected by devices
v STORIOA
Response:
573E8400 573E8400
573E9010 573E9010
Explanation: Licensed Internal Code error
Explanation: Cache data associated with attached
Failing Item: devices cannot be found
v PTFSRCH
Response:
Failing Item:
573E8404 573E8404
v IOPIP31
Explanation: System log entry only. No service action
required.
573E9011 573E9011
573E9020 573E9020
573E9001 573E9001
Explanation: Array not functional due to present
Explanation: Device configuration error
hardware configuration.
Response:
Response:
Failing Item:
Failing Item:
v IOPIP33
v IOPIP20
573E9040 573E9040
573E9053 573E9053
Explanation: Array protection temporarily suspended
Explanation: IOA resources not available due to
Response: No action required. Protection will be previous problems
automatically restarted.
Response: Take action on other reference codes which
have surfaced.
573E9041 573E9041
If you cannot get to SST or DST, and cannot perform a
Explanation: Background array parity check detected type A or B IPL, perform a type D IPL from removable
and corrected errors media. Look for Product Activity Log entries for other
reference codes and take action on them.
Response: Call your next level of support to report
the problem. Failing Item:
Failing Item: v SVCDOCS
v PTFSRCH
573E9054 573E9054
573E9042 573E9042 Explanation: IOA resources not available due to
previous problems
Explanation: An array parity error has been detected
and corrected Response: Power off the system and remove all new
or replacement disk units. IPL the system to DST. If
Response: Call your next level of support to report
you cannot perform a type A or B IPL, perform a type
the problem.
D IPL from removable media.
Failing Item:
Look for Product Activity Log entries for other
v NEXTLVL reference codes and take action on them.
Failing Item:
573E9050 573E9050
v SVCDOCS
Explanation: Required cache data cannot be located
for a disk unit.
573E9071 573E9071
Response:
Explanation: Link from IOA to auxiliary cache IOA
Failing Item: went operational
v IOPIP30 Response: No service action required.
Response:
573E9903 573E9903
Failing Item:
Explanation: Tape device information was logged.
v IOPIP16
Informational event, no service required.
v FI01105
v STORIOA
573EC000 573EC000
v FI01140
Explanation: System log entry only. No service action
v BACKPLN
required.
v FI01106
Response: No action is required. This reference code
is logged for information only.
573E9090 573E9090
Explanation: Disk unit has been modified after the 573EC100 573EC100
last known status.
Explanation: System log entry only. No service action
Response: Re-IPL the system. If any reference codes required.
are surfaced, use the new reference code to resolve the
problem. Response: No action is required. This reference code
is logged for information only.
If you cannot resolve the problem, contact your next
level of support.
573EC402 573EC402
Failing Item:
Explanation: Licensed Internal Code error
v SVCDOCS
Response: Ask your next level of support for
assistance.
573E9091 573E9091
Failing Item:
Explanation: Incorrect hardware configuration change
detected v PTFSRCH
573EFF6D 573EFF6D
Explanation: Recoverable system bus error
Failing Item:
v STORIOA
v ANYBRDG
v PTFSRCH
Note: Use this table to handle reference codes that might be displayed during a
type D IPL to install the operating system. If you are not performing a type D IPL
of the operating system, consult any error logs found in the serviceable event view.
If you cannot locate an error log in the serviceable event view that corresponds
with the failure, run a verification test for the tape unit.
1. Verify that the device has power.
2. Check the device for any error indications. Refer to the device service
information to resolve any error indications.
3. Clean the recording head in the tape device.
4. Attempt the failing operation again. Does the operation complete successfully?
Yes: You have corrected the problem. This ends the procedure.
No: Look at the 8 rightmost characters of the Data display for Function 11,
which represent the reference code. Find the reference code in the following
list.
v FI00872 v FI00871
v DEVTERM v FI01112
v SASCABL
57469101 57469101
Explanation: Fibre Channel interface error detected 57469200 57469200
Response: If the attached device is an external device, Explanation: Tape unit is not responding
do the following before exchanging any parts: Response: If the attached device is an external device,
1. Ensure that the Fibre Channel cable is correctly do the following before exchanging any parts:
connected to the ports. 1. Ensure that the device is powered on.
2. Clean the Fibre Channel connectors. 2. Ensure that the signal cable is seated correctly, and
3. If there is a switch or hub attached, verify that it is that there are no bent or damaged pins on the cable.
operational. 3. For a SCSI attached device ensure that a
4. If there is a gateway device attached, refer to the terminating plug is attached to the device end of
gateway device service documentation for the SCSI cable.
additional problem analysis procedures.
5. refer to the tape device service documentation for If the attached tape device is owned by a Virtual I/O
additional problem analysis procedures. Server partition refer to Troubleshooting the Virtual
I/O Server to determine the parts to replace.
If the attached tape device is owned by a Virtual I/O Failing Item:
Server partition refer to Troubleshooting the Virtual
v FI00871
I/O Server to determine the parts to replace.
v FI01112
Failing Item:
v FI00872
v FCIOA
v DEVTERM
v FCDEV
v FCCABLE
57469201 57469201
Explanation: Tape unit command timeout
57469102 57469102
Response: If the attached device is an external device,
Explanation: Gateway device detected a SCSI interface
do the following before exchanging any parts:
error
1. Ensure that the device is powered on.
Response: Use the gateway device service
2. If an interposer is required, make sure that it is
documentation to analyze the problem.
connected between the I/O processor and the SCSI
Failing Item: cable.
v FI00871 3. Ensure that the signal cable is seated correctly, and
v FCGATE that there are no bent or damaged pins on the SCSI
cable.
v FI00872
4. Ensure that a terminating plug is attached to the
v DEVTERM
device end of the SCSI cable.
5. If the attached tape device is owned by a Virtual
57469103 57469103 I/O Server partition it may be necessary to reset the
Explanation: Interface error detected by system or by virtual IOP to recover from the error.
tape unit Failing Item:
Response: If the attached device is an external tape v FI00871
device, do the following before exchanging any parts: v FI01112
1. Ensure that the SAS cable is correctly connected to v FI00872
the ports.
v DEVTERM
2. Ensure that the device has power.
v MEDIA
If the attached tape device is owned by a Virtual I/O
Server partition refer to Troubleshooting the Virtual
I/O Server to determine the parts to replace.
Failing Item:
Failing Item:
57469302 57469302
v FI00871
v FI01112 Explanation: Tape device failure or media error
Failing Item:
57469304 57469304
v FCGATE
v FCIOA Explanation: Tape unit failure
57469899 57469899
Explanation: Problem analysis completed, the problem
has been corrected.
Response: This reference code is used for ending
Online Problem Analysis when no problem was found
or the problem was corrected.
57469900 57469900
Explanation: Licensed Internal Code for tape unit was
not upgraded
Response: The I/O processor loading of Licensed
Internal Code (LIC) to the programmable tape unit was
not completed.
The tape unit will continue to operate with the
previous LIC. You may do either of the following:
v Wait for next IPL when the system will attempt to
load the LIC for the tape drive again.
v Perform TUPIP04 to reset the IOP and the tape unit.
When the IOP is reset, if the device has the wrong
level of LIC, the IOP will attempt to load the new
LIC.
Failing Item:
v USER
v The embedded storage adapter on the I/O Card type 2BE1 (feature RAID enablement card for
backplane. embedded IOA) read the following: When working the
v The RAID enablement card. FRUs from the serviceable event or the failing item list
here, the embedded storage adapter (STORIOA) has
v The Battery charger and carrier card. three physical parts:
v The embedded storage adapter on the I/O
See symbolic FRU FEATCRD for the location codes of
backplane.
the FRUs if they are not listed in the serviceable event
or if you are working the failing item list here. v The RAID enablement card.
v The Battery charger and carrier card.
Card type 57CB (embedded IOA with 2BCF battery
card for embedded IOA) read the following: When See symbolic FRU FEATCRD for the location codes of
working the FRUs from the serviceable event or the the FRUs if they are not listed in the serviceable event
failing item list here, the embedded storage adapter or if you are working the failing item list here.
(STORIOA) has two physical parts:
Card type 57CB (embedded IOA with 2BCF battery v The RAID enablement card.
card for embedded IOA) read the following: When v The Battery charger and carrier card.
working the FRUs from the serviceable event or the
failing item list here, the embedded storage adapter See symbolic FRU FEATCRD for the location codes of
(STORIOA) has two physical parts: the FRUs if they are not listed in the serviceable event
v The embedded storage adapter on the I/O or if you are working the failing item list here.
backplane.
v The Battery charger and carrier card. Card type 57CB (embedded IOA with 2BCF battery
card) read the following: When working the FRUs from
See symbolic FRU FEATCRD for the location codes of the serviceable event or the failing item list here, the
the FRUs if they are not listed in the serviceable event embedded storage adapter (STORIOA) has two
or if you are working the failing item list here. physical parts:
v The embedded storage adapter on the I/O
Card type 57CF (embedded IOAs on DASD backplane backplane.
with 2BC2 dual battery charger and carrier card for the v The Battery charger and carrier card.
embedded IOAs) read the following: When working
the FRUs from the serviceable event or the failing item See symbolic FRU FEATCRD for the location codes of
list here, the embedded storage adapters (STORIOA) the FRUs if they are not listed in the serviceable event
have two physical parts: or if you are working the failing item list here.
v The embedded storage adapter on the DASD
backplane. Card type 57CF (embedded IOAs on DASD backplane
v The dual battery charger and carrier card. To with 2BC2 dual battery charger and carrier card) read
determine which battery is connected to which the following: When working the FRUs from the
embedded IOA use the bus number of the IOA with serviceable event or the failing item list here, the
symbolic FRU CACHBAT. embedded storage adapters (STORIOA) have two
physical parts:
See symbolic FRU FEATCRD for the location code of v The embedded storage adapter on the DASD
the dual battery charger and carrier card if it is not backplane.
listed in the serviceable event or if you are working the v The dual battery charger and carrier card. To
failing item list here. determine which battery is connected to which
Failing Item: embedded IOA use the bus number of the IOA with
symbolic FRU CACHBAT.
v BACKPLN
v STORIOA See symbolic FRU FEATCRD for the location code of
the dual battery charger and carrier card if it is not
574E8008 574E8008 listed in the serviceable event or if you are working the
failing item list here.
Explanation: A permanent cache battery pack failure
occurred Failing Item:
v CACHBAT
Response: Under a certain configuration, this SRC
may not represent an error that requires a service v STORIOA
action. Depending on the configuration of the system, v FEATCRD
the Storage IOA may have been altered and/or the
Storage IOA Cache may have been disabled to allow
attachment of OEM Storage that emulates a Load 574E8009 574E8009
Source drive. If this is the case, this error will be posted Explanation: Impending cache battery pack failure
each time the IOA is IPLed and it can be ignored.
Failing Item:
If you are working with one of the card types below,
v CACHBAT
the adapter has mulitple physical parts. Choose the
card type to identify the physical parts of the storage
adapter. 574E8100 574E8100
Card type 2BE1 (feature RAID enablement card for Explanation: Licensed Internal Code error
embedded IOA) read the following: When working the
Response: If you are working with one of the card
FRUs from the serviceable event or the failing item list
types below, the adapter has mulitple physical parts.
here, the embedded storage adapter (STORIOA) has
Choose the card type to identify the physical parts of
three physical parts:
the storage adapter.
v The embedded storage adapter on the I/O
backplane. Card type 2BE1 (feature RAID enablement card for
Card type 57CB (embedded IOA with 2BCF battery Card type 57CB (embedded IOA with 2BCF battery
card for embedded IOA) read the following: When card for embedded IOA) read the following: When
working the FRUs from the serviceable event or the working the FRUs from the serviceable event or the
failing item list here, the embedded storage adapter failing item list here, the embedded storage adapter
(STORIOA) has two physical parts: (STORIOA) has two physical parts:
v The embedded storage adapter on the I/O v The embedded storage adapter on the I/O
backplane. backplane.
v The Battery charger and carrier card. v The Battery charger and carrier card.
See symbolic FRU FEATCRD for the location codes of See symbolic FRU FEATCRD for the location codes of
the FRUs if they are not listed in the serviceable event the FRUs if they are not listed in the serviceable event
or if you are working the failing item list here. or if you are working the failing item list here.
Card type 57CF (embedded IOAs on DASD backplane Card type 57CF (embedded IOAs on DASD backplane
with 2BC2 dual battery charger and carrier card for the with 2BC2 dual battery charger and carrier card for the
embedded IOAs) read the following: When working embedded IOAs) read the following: When working
the FRUs from the serviceable event or the failing item the FRUs from the serviceable event or the failing item
list here, the embedded storage adapters (STORIOA) list here, the embedded storage adapters (STORIOA)
have two physical parts: have two physical parts:
v The embedded storage adapter on the DASD v The embedded storage adapter on the DASD
backplane. backplane.
v The dual battery charger and carrier card. To v The dual battery charger and carrier card. To
determine which battery is connected to which determine which battery is connected to which
embedded IOA use the bus number of the IOA with embedded IOA use the bus number of the IOA with
symbolic FRU CACHBAT. symbolic FRU CACHBAT.
See symbolic FRU FEATCRD for the location code of See symbolic FRU FEATCRD for the location code of
the dual battery charger and carrier card if it is not the dual battery charger and carrier card if it is not
listed in the serviceable event or if you are working the listed in the serviceable event or if you are working the
failing item list here. failing item list here.
Failing Item: Failing Item:
v STORIOA v PTFSRCH
v ANYBRDG v STORIOA
See symbolic FRU FEATCRD for the location codes of See symbolic FRU FEATCRD for the location codes of
the FRUs if they are not listed in the serviceable event the FRUs if they are not listed in the serviceable event
or if you are working the failing item list here. or if you are working the failing item list here.
Card type 57CB (embedded IOA with 2BCF battery Card type 57CB (embedded IOA with 2BCF battery
card for embedded IOA) read the following: When card for embedded IOA) read the following: When
working the FRUs from the serviceable event or the working the FRUs from the serviceable event or the
failing item list here, the embedded storage adapter failing item list here, the embedded storage adapter
(STORIOA) has two physical parts: (STORIOA) has two physical parts:
v The embedded storage adapter on the I/O v The embedded storage adapter on the I/O
backplane. backplane.
v The Battery charger and carrier card. v The Battery charger and carrier card.
See symbolic FRU FEATCRD for the location codes of See symbolic FRU FEATCRD for the location codes of
the FRUs if they are not listed in the serviceable event the FRUs if they are not listed in the serviceable event
or if you are working the failing item list here. or if you are working the failing item list here.
Card type 57CF (embedded IOAs on DASD backplane Card type 57CF (embedded IOAs on DASD backplane
with 2BC2 dual battery charger and carrier card for the with 2BC2 dual battery charger and carrier card for the
embedded IOAs) read the following: When working embedded IOAs) read the following: When working
the FRUs from the serviceable event or the failing item the FRUs from the serviceable event or the failing item
list here, the embedded storage adapters (STORIOA) list here, the embedded storage adapters (STORIOA)
have two physical parts: have two physical parts:
v The embedded storage adapter on the DASD v The embedded storage adapter on the DASD
backplane. backplane.
v The dual battery charger and carrier card. To v The dual battery charger and carrier card. To
determine which battery is connected to which determine which battery is connected to which
embedded IOA use the bus number of the IOA with embedded IOA use the bus number of the IOA with
symbolic FRU CACHBAT. symbolic FRU CACHBAT.
See symbolic FRU FEATCRD for the location code of See symbolic FRU FEATCRD for the location code of
the dual battery charger and carrier card if it is not the dual battery charger and carrier card if it is not
listed in the serviceable event or if you are working the listed in the serviceable event or if you are working the
failing item list here. failing item list here.
Failing Item: Failing Item:
v PTFSRCH v PTFSRCH
v STORIOA v STORIOA
v The embedded storage adapter on the I/O v The embedded storage adapter on the I/O
backplane. backplane.
v The RAID enablement card. v The RAID enablement card.
v The Battery charger and carrier card. v The Battery charger and carrier card.
See symbolic FRU FEATCRD for the location codes of See symbolic FRU FEATCRD for the location codes of
the FRUs if they are not listed in the serviceable event the FRUs if they are not listed in the serviceable event
or if you are working the failing item list here. or if you are working the failing item list here.
Card type 57CB (embedded IOA with 2BCF battery Card type 57CB (embedded IOA with 2BCF battery
card for embedded IOA) read the following: When card for embedded IOA) read the following: When
working the FRUs from the serviceable event or the working the FRUs from the serviceable event or the
failing item list here, the embedded storage adapter failing item list here, the embedded storage adapter
(STORIOA) has two physical parts: (STORIOA) has two physical parts:
v The embedded storage adapter on the I/O v The embedded storage adapter on the I/O
backplane. backplane.
v The Battery charger and carrier card. v The Battery charger and carrier card.
See symbolic FRU FEATCRD for the location codes of See symbolic FRU FEATCRD for the location codes of
the FRUs if they are not listed in the serviceable event the FRUs if they are not listed in the serviceable event
or if you are working the failing item list here. or if you are working the failing item list here.
Card type 57CF (embedded IOAs on DASD backplane Card type 57CF (embedded IOAs on DASD backplane
with 2BC2 dual battery charger and carrier card for the with 2BC2 dual battery charger and carrier card for the
embedded IOAs) read the following: When working embedded IOAs) read the following: When working
the FRUs from the serviceable event or the failing item the FRUs from the serviceable event or the failing item
list here, the embedded storage adapters (STORIOA) list here, the embedded storage adapters (STORIOA)
have two physical parts: have two physical parts:
v The embedded storage adapter on the DASD v The embedded storage adapter on the DASD
backplane. backplane.
v The dual battery charger and carrier card. To v The dual battery charger and carrier card. To
determine which battery is connected to which determine which battery is connected to which
embedded IOA use the bus number of the IOA with embedded IOA use the bus number of the IOA with
symbolic FRU CACHBAT. symbolic FRU CACHBAT.
See symbolic FRU FEATCRD for the location code of See symbolic FRU FEATCRD for the location code of
the dual battery charger and carrier card if it is not the dual battery charger and carrier card if it is not
listed in the serviceable event or if you are working the listed in the serviceable event or if you are working the
failing item list here. failing item list here.
Failing Item: Failing Item:
v SVCDOCS v STORIOA
v STORIOA v ANYBRDG
v PTFSRCH
574E8300 574E8300
Explanation: IOA hardware error or PCI bus error 574E8301 574E8301
Response: If you are working with one of the card Explanation: Not valid condition in Licensed Internal
types below, the adapter has mulitple physical parts. Code
Choose the card type to identify the physical parts of Response: If you are working with one of the card
the storage adapter. types below, the adapter has mulitple physical parts.
Card type 2BE1 (feature RAID enablement card for Choose the card type to identify the physical parts of
embedded IOA) read the following: When working the the storage adapter.
FRUs from the serviceable event or the failing item list Card type 2BE1 (feature RAID enablement card for
here, the embedded storage adapter (STORIOA) has embedded IOA) read the following: When working the
three physical parts: FRUs from the serviceable event or the failing item list
here, the embedded storage adapter (STORIOA) has FRUs from the serviceable event or the failing item list
three physical parts: here, the embedded storage adapter (STORIOA) has
v The embedded storage adapter on the I/O three physical parts:
backplane. v The embedded storage adapter on the I/O
v The RAID enablement card. backplane.
v The Battery charger and carrier card. v The RAID enablement card.
v The Battery charger and carrier card.
See symbolic FRU FEATCRD for the location codes of
the FRUs if they are not listed in the serviceable event See symbolic FRU FEATCRD for the location codes of
or if you are working the failing item list here. the FRUs if they are not listed in the serviceable event
or if you are working the failing item list here.
Card type 57CB (embedded IOA with 2BCF battery
card for embedded IOA) read the following: When Card type 57CB (embedded IOA with 2BCF battery
working the FRUs from the serviceable event or the card for embedded IOA) read the following: When
failing item list here, the embedded storage adapter working the FRUs from the serviceable event or the
(STORIOA) has two physical parts: failing item list here, the embedded storage adapter
v The embedded storage adapter on the I/O (STORIOA) has two physical parts:
backplane. v The embedded storage adapter on the I/O
v The Battery charger and carrier card. backplane.
v The Battery charger and carrier card.
See symbolic FRU FEATCRD for the location codes of
the FRUs if they are not listed in the serviceable event See symbolic FRU FEATCRD for the location codes of
or if you are working the failing item list here. the FRUs if they are not listed in the serviceable event
or if you are working the failing item list here.
Card type 57CF (embedded IOAs on DASD backplane
with 2BC2 dual battery charger and carrier card for the Card type 57CF (embedded IOAs on DASD backplane
embedded IOAs) read the following: When working with 2BC2 dual battery charger and carrier card for the
the FRUs from the serviceable event or the failing item embedded IOAs) read the following: When working
list here, the embedded storage adapters (STORIOA) the FRUs from the serviceable event or the failing item
have two physical parts: list here, the embedded storage adapters (STORIOA)
v The embedded storage adapter on the DASD have two physical parts:
backplane. v The embedded storage adapter on the DASD
v The dual battery charger and carrier card. To backplane.
determine which battery is connected to which v The dual battery charger and carrier card. To
embedded IOA use the bus number of the IOA with determine which battery is connected to which
symbolic FRU CACHBAT. embedded IOA use the bus number of the IOA with
symbolic FRU CACHBAT.
See symbolic FRU FEATCRD for the location code of
the dual battery charger and carrier card if it is not See symbolic FRU FEATCRD for the location code of
listed in the serviceable event or if you are working the the dual battery charger and carrier card if it is not
failing item list here. listed in the serviceable event or if you are working the
failing item list here.
Failing Item:
v PTFSRCH Failing Item:
v STORIOA v SVCDOCS
v STORIOA
574E8302 574E8302
574E8400 574E8400
Explanation: Missing Licensed Internal Code
Explanation: Licensed Internal Code error
Response: Ensure that the code necessary to support
this I/O adapter is loaded. Failing Item:
If you are working with one of the card types below, v PTFSRCH
the adapter has mulitple physical parts. Choose the
card type to identify the physical parts of the storage
adapter.
Card type 2BE1 (feature RAID enablement card for
embedded IOA) read the following: When working the
v FI01105
574E8404 574E8404
v STORIOA
Explanation: System log entry only. No service action
required.
574E9001 574E9001
See symbolic FRU FEATCRD for the location codes of Failing Item:
the FRUs if they are not listed in the serviceable event v NEXTLVL
or if you are working the failing item list here.
574E9020 574E9020
Card type 57CF (embedded IOAs on DASD backplane
with 2BC2 dual battery charger and carrier card for the Explanation: Two or more disk units missing from
embedded IOAs) read the following: When working RAID-5 or RAID-6 array
the FRUs from the serviceable event or the failing item
Failing Item:
list here, the embedded storage adapters (STORIOA)
have two physical parts: v SIP3111
v The embedded storage adapter on the DASD
backplane. 574E9021 574E9021
v The dual battery charger and carrier card. To Explanation: Two or more disk units missing from
determine which battery is connected to which RAID-5 or RAID-6 array
embedded IOA use the bus number of the IOA with
symbolic FRU CACHBAT. Failing Item:
v SIP3111
See symbolic FRU FEATCRD for the location code of
the dual battery charger and carrier card if it is not
listed in the serviceable event or if you are working the
failing item list here.
Failing Item:
Failing Item:
574E9031 574E9031
v SIP3110
v FI02112 Explanation: Automatic rebuild initiated for array
Response: Either a previous rebuild was interrupted
574E9026 574E9026 and was automatically restarted, or a hot spare disk
unit was used to automatically rebuild the array. Look
Explanation: Disk unit not found at required physical for other reference codes and take action on them.
location
Response: A previously exposed disk unit in an array 574E9032 574E9032
was not found at the required physical location.
Explanation: A disk unit in an array is missing or
Failing Item: failed
v NEXTLVL
Response: The array is still protected, but the disk
unit should be replaced.
574E9027 574E9027
Failing Item:
Explanation: Array not functional due to parity out of v SIP3110
synchronization
v FI02112
Response: Array is or would become exposed and
parity data is out of synchronization
574E9040 574E9040
Failing Item:
Explanation: Re-synchronization of array parity was
v SIP3113 initiated
Response: No action required.
v The embedded storage adapter on the I/O v The embedded storage adapter on the I/O
backplane. backplane.
v The RAID enablement card. v The RAID enablement card.
v The Battery charger and carrier card. v The Battery charger and carrier card.
See symbolic FRU FEATCRD for the location codes of See symbolic FRU FEATCRD for the location codes of
the FRUs if they are not listed in the serviceable event the FRUs if they are not listed in the serviceable event
or if you are working the failing item list here. or if you are working the failing item list here.
Card type 57CB (embedded IOA with 2BCF battery Card type 57CB (embedded IOA with 2BCF battery
card for embedded IOA) read the following: When card for embedded IOA) read the following: When
working the FRUs from the serviceable event or the working the FRUs from the serviceable event or the
failing item list here, the embedded storage adapter failing item list here, the embedded storage adapter
(STORIOA) has two physical parts: (STORIOA) has two physical parts:
v The embedded storage adapter on the I/O v The embedded storage adapter on the I/O
backplane. backplane.
v The Battery charger and carrier card. v The Battery charger and carrier card.
See symbolic FRU FEATCRD for the location codes of See symbolic FRU FEATCRD for the location codes of
the FRUs if they are not listed in the serviceable event the FRUs if they are not listed in the serviceable event
or if you are working the failing item list here. or if you are working the failing item list here.
Card type 57CF (embedded IOAs on DASD backplane Card type 57CF (embedded IOAs on DASD backplane
with 2BC2 dual battery charger and carrier card for the with 2BC2 dual battery charger and carrier card for the
embedded IOAs) read the following: When working embedded IOAs) read the following: When working
the FRUs from the serviceable event or the failing item the FRUs from the serviceable event or the failing item
list here, the embedded storage adapters (STORIOA) list here, the embedded storage adapters (STORIOA)
have two physical parts: have two physical parts:
v The embedded storage adapter on the DASD v The embedded storage adapter on the DASD
backplane. backplane.
v The dual battery charger and carrier card. To v The dual battery charger and carrier card. To
determine which battery is connected to which determine which battery is connected to which
embedded IOA use the bus number of the IOA with embedded IOA use the bus number of the IOA with
symbolic FRU CACHBAT. symbolic FRU CACHBAT.
See symbolic FRU FEATCRD for the location code of See symbolic FRU FEATCRD for the location code of
the dual battery charger and carrier card if it is not the dual battery charger and carrier card if it is not
listed in the serviceable event or if you are working the listed in the serviceable event or if you are working the
failing item list here. failing item list here.
Failing Item: Failing Item:
v FI01105 v FI01105
v STORIOA v STORIOA
If you cannot resolve the problem, contact your next Explanation: I/O adapter detected a recoverable error
level of support. Response: If you are working with one of the card
Failing Item: types below, the adapter has mulitple physical parts.
Choose the card type to identify the physical parts of
v SVCDOCS
the storage adapter.
Card type 2BE1 (feature RAID enablement card for
574E9091 574E9091
embedded IOA) read the following: When working the
Explanation: Incorrect hardware configuration change FRUs from the serviceable event or the failing item list
detected here, the embedded storage adapter (STORIOA) has
three physical parts:
Response: Use Hardware Service Manager to re-IPL
the virtual I/O processor that is associated with this v The embedded storage adapter on the I/O
I/O adapter. Other resources attached to the virtual backplane.
I/O processor may then need to be Varied On. v The RAID enablement card.
If any reference codes are surfaced, use the new v The Battery charger and carrier card.
reference code to resolve the problem.
See symbolic FRU FEATCRD for the location codes of
If you cannot resolve the problem, contact your next the FRUs if they are not listed in the serviceable event
level of support. or if you are working the failing item list here.
Failing Item:
Card type 57CB (embedded IOA with 2BCF battery
v SVCDOCS
card for embedded IOA) read the following: When
working the FRUs from the serviceable event or the
574E9092 574E9092 failing item list here, the embedded storage adapter
(STORIOA) has two physical parts:
Explanation: Disk unit requires initialization before
use. v The embedded storage adapter on the I/O
backplane.
Failing Item:
v The Battery charger and carrier card.
v SIP3134
See symbolic FRU FEATCRD for the location codes of
574E9500 574E9500 the FRUs if they are not listed in the serviceable event
or if you are working the failing item list here.
Explanation: Internal program error in driver code.
Failing Item: Card type 57CF (embedded IOAs on DASD backplane
with 2BC2 dual battery charger and carrier card for the
v PTFSRCH
embedded IOAs) read the following: When working
the FRUs from the serviceable event or the failing item
574E9903 574E9903 list here, the embedded storage adapters (STORIOA)
have two physical parts:
Explanation: Tape device information was logged.
Informational event, no service required. v The embedded storage adapter on the DASD
backplane.
v The dual battery charger and carrier card. To
574EC000 574EC000 determine which battery is connected to which
Explanation: System log entry only. No service action embedded IOA use the bus number of the IOA with
required. symbolic FRU CACHBAT.
Response: Error occurred on SCSI bus 0. Explanation: Impending cache battery pack failure
Response: v AUXIOA
Failing Item:
574F8302 574F8302
v PTFSRCH
v AUXIOA Explanation: Missing Licensed Internal Code
Response: Ensure that the code necessary to support
574F8156 574F8156 this I/O adapter is loaded.
574F9071 574F9071
Explanation: Link from IOA to auxiliary cache IOA
went operational
Response: No service action required.
574F9072 574F9072
Explanation: Link from IOA to auxiliary cache IOA
went non-operational
Response: No service action required.
574F9073 574F9073
Explanation: Disconnected, incompatible, or
non-operational storage IOA
Response:
Failing Item:
v IOPIP41
574FFF3D 574FFF3D
Explanation: I/O adapter detected recoverable error
Response:
Failing Item:
v AUXIOA
v ANYBRDG
Note: Use this table to handle reference codes that might be displayed during a
type D IPL to install the operating system. If you are not performing a type D IPL
of the operating system, consult any error logs found in the serviceable event view.
If you cannot locate an error log in the serviceable event view that corresponds
with the failure, run a verification test for the tape unit.
1. Verify that the device has power.
2. Check the device for any error indications. Refer to the device service
information to resolve any error indications.
3. Clean the recording head in the tape device.
4. Attempt the failing operation again. Does the operation complete successfully?
Yes: You have corrected the problem. This ends the procedure.
No: Look at the 8 rightmost characters of the Data display for Function 11,
which represent the reference code. Find the reference code in the following
list.
v FI00872 v FI00871
v DEVTERM v FI01112
v SASCABL
57559101 57559101
Explanation: Fibre Channel interface error detected 57559200 57559200
Response: If the attached device is an external device, Explanation: Tape unit is not responding
do the following before exchanging any parts: Response: If the attached device is an external device,
1. Ensure that the Fibre Channel cable is correctly do the following before exchanging any parts:
connected to the ports. 1. Ensure that the device is powered on.
2. Clean the Fibre Channel connectors. 2. Ensure that the signal cable is seated correctly, and
3. If there is a switch or hub attached, verify that it is that there are no bent or damaged pins on the cable.
operational. 3. For a SCSI attached device ensure that a
4. If there is a gateway device attached, refer to the terminating plug is attached to the device end of
gateway device service documentation for the SCSI cable.
additional problem analysis procedures.
5. refer to the tape device service documentation for If the attached tape device is owned by a Virtual I/O
additional problem analysis procedures. Server partition refer to Troubleshooting the Virtual
I/O Server to determine the parts to replace.
If the attached tape device is owned by a Virtual I/O Failing Item:
Server partition refer to Troubleshooting the Virtual
v FI00871
I/O Server to determine the parts to replace.
v FI01112
Failing Item:
v FI00872
v FCIOA
v DEVTERM
v FCDEV
v FCCABLE
57559201 57559201
Explanation: Tape unit command timeout
57559102 57559102
Response: If the attached device is an external device,
Explanation: Gateway device detected a SCSI interface
do the following before exchanging any parts:
error
1. Ensure that the device is powered on.
Response: Use the gateway device service
2. If an interposer is required, make sure that it is
documentation to analyze the problem.
connected between the I/O processor and the SCSI
Failing Item: cable.
v FI00871 3. Ensure that the signal cable is seated correctly, and
v FCGATE that there are no bent or damaged pins on the SCSI
cable.
v FI00872
4. Ensure that a terminating plug is attached to the
v DEVTERM
device end of the SCSI cable.
5. If the attached tape device is owned by a Virtual
57559103 57559103 I/O Server partition it may be necessary to reset the
Explanation: Interface error detected by system or by virtual IOP to recover from the error.
tape unit Failing Item:
Response: If the attached device is an external tape v FI00871
device, do the following before exchanging any parts: v FI01112
1. Ensure that the SAS cable is correctly connected to v FI00872
the ports.
v DEVTERM
2. Ensure that the device has power.
v MEDIA
If the attached tape device is owned by a Virtual I/O
Server partition refer to Troubleshooting the Virtual
I/O Server to determine the parts to replace.
Failing Item:
Failing Item:
57559302 57559302
v FI00871
v FI01112 Explanation: Tape device failure or media error
Failing Item:
57559304 57559304
v FCGATE
v FCIOA Explanation: Tape unit failure
57559899 57559899
Explanation: Problem analysis completed, the problem
has been corrected.
Response: This reference code is used for ending
Online Problem Analysis when no problem was found
or the problem was corrected.
57559900 57559900
Explanation: Licensed Internal Code for tape unit was
not upgraded
Response: The I/O processor loading of Licensed
Internal Code (LIC) to the programmable tape unit was
not completed.
The tape unit will continue to operate with the
previous LIC. You may do either of the following:
v Wait for next IPL when the system will attempt to
load the LIC for the tape drive again.
v Perform TUPIP04 to reset the IOP and the tape unit.
When the IOP is reset, if the device has the wrong
level of LIC, the IOP will attempt to load the new
LIC.
Failing Item:
v USER
Response: Error occurred on SCSI bus 0. Explanation: Impending cache battery pack failure
Response: v AUXIOA
Failing Item:
575B8302 575B8302
v PTFSRCH
v AUXIOA Explanation: Missing Licensed Internal Code
Response: Ensure that the code necessary to support
575B8156 575B8156 this I/O adapter is loaded.
575B9071 575B9071
Explanation: Link from IOA to auxiliary cache IOA
went operational
Response: No service action required.
575B9072 575B9072
Explanation: Link from IOA to auxiliary cache IOA
went non-operational
Response: No service action required.
575B9073 575B9073
Explanation: Disconnected, incompatible, or
non-operational storage IOA
Response:
Failing Item:
v IOPIP41
575BFF3D 575BFF3D
Explanation: I/O adapter detected recoverable error
Response:
Failing Item:
v AUXIOA
v ANYBRDG
Explanation: I/O adapter detected recoverable bus SVCDOCS, then do NOT replace the I/O adapter. This
error is a recoverable error. Use Hardware Service Manager
to re-IPL the virtual I/O processor that is associated
Response: If this event appears in a serviceable event
with this I/O adapter.
view, work with the failing item list found there. If this
event does not appear in a serviceable event view, no Failing Item:
service action is required. v SVCDOCS
Failing Item:
v PRIMIOA 575C8300 575C8300
v AUXIOA Explanation: IOA hardware or PCI bus error
v BACKPLN
Failing Item:
v AUXIOA
575C8150 575C8150
v ANYBRDG
Explanation: A permanent failure occurred v PTFSRCH
Response: NOTE: Under a certain configuration, this
SRC may not represent an error that requires a service 575C8301 575C8301
action. Depending on the configuration of the system,
the Storage IOA may have been altered and/or the Explanation: Not valid condition in Licensed Internal
Storage IOA Cache may have been disabled to allow Code
attachment of OEM Storage that emulates a Load Failing Item:
Source drive. If this is the case, this error will be posted
each time the IOA is IPLed and it can be ignored. v PTFSRCH
v AUXIOA
Failing Item:
v AUXIOA
575C8302 575C8302
v ANYBRDG
Explanation: Missing Licensed Internal Code
575C8151 575C8151 Response: Ensure that the code necessary to support
this I/O adapter is loaded.
Explanation: Licensed Internal Code error
Failing Item:
Failing Item:
v SVCDOCS
v PTFSRCH
v AUXIOA
v AUXIOA
575C9055 575C9055
575C8155 575C8155
Explanation: Write cache data is available for attached
Explanation: A permanent failure occurred storage IOA
Failing Item: Response: No service action required.
v PTFSRCH
v AUXIOA 575C9071 575C9071
Explanation: Link from IOA to auxiliary cache IOA
575C8156 575C8156 went operational
Explanation: A permanent failure occurred Response: No service action required.
Failing Item:
v PTFSRCH 575C9072 575C9072
v AUXIOA Explanation: Link from IOA to auxiliary cache IOA
went non-operational
575C8157 575C8157 Response: No service action required.
Explanation: I/O adapter card error
Response: Display the Service Action Log entry for
this SRC. If the Failing Item indicates I/O adapter, then
replace the I/O adapter. If the Failing Item indicates
575C9073 575C9073
Explanation: Multiple I/O adapters connected in a not
valid configuration
Failing Item:
v SIP3140
575C9076 575C9076
Explanation: Missing remote I/O adapter
Failing Item:
v SIP3147
v PRIMIOA
v AUXIOA
v BACKPLN
575CFF3D 575CFF3D
Explanation: I/O adapter detected recoverable error
Response: If this event appears in a serviceable event
view, work with the failing item list found there. If this
event does not appear in a serviceable event view, no
service action is required.
Failing Item:
v AUXIOA
v ANYBRDG
5767B9B0 5767B9B0
Explanation: I/O adapter hardware error detected
Failing Item:
v IOA
v AJDGP01
5768B9B0 5768B9B0
Explanation: I/O adapter hardware error detected
Failing Item:
v IOA
v AJDGP01
576AB9B0 576AB9B0
Explanation: I/O adapter hardware error detected
Failing Item:
v IOA
v AJDG301
Explanation: A port failure was detected on port 0 v Check the Product Activity Log for other entries that
indicate interface problems and work those
Failing Item: problems.
v FCPORT v Check the device firmware level and apply the latest
v FCIOA PTFs.
v FCDEV v Check for LIC logs with major code 2E00. Contact
your next level of support with the information you
v OPT_CLN
have gathered.
Problem determination: IPL the IOP to retry the
576B3121 576B3121
device identification process. If the error persists then
Explanation: A port failure was detected on port 1 contact your service provider.
Failing Item: Failing Item:
v PTFSRCH
576B8300 576B8300
Explanation: IOA hardware error or PCI bus error
576B34FF 576B34FF
Failing Item:
Explanation: Format in progress
v FCIOA
Response: The device indicated that a format is in
v ANYBRDG
progress. When the format is complete, the device
should be usable. No action is required. This reference v PTFSRCH
code is logged for information only. v OPT_CLN
576B8131 576B8131
576B9903 576B9903
Explanation: Recovered Fibre Channel interface error
on port 1 Explanation: Tape device information was logged.
Informational event, no service required.
Response: No action required. This reference code is
logged for information only.
576BB000 576BB000
576BC000 576BC000
Explanation: System log entry only, no service action
required
Response: No action is required. This reference code
is logged for information only.
576BC402 576BC402
Explanation: Licensed Internal Code error
Failing Item:
v PTFSRCH
576CB940 576CB940
Explanation: I/O adapter hardware error detected
Failing Item:
v FI00719
v AJDGP01
v MA_BRDG
576CB941 576CB941
Explanation: One of the ports on the IOA has failed.
Failing Item:
v FI00719
v AJDGP01
576DB9B0 576DB9B0
Explanation: I/O adapter hardware error detected
Failing Item:
v IOA
v AJDG301
576EB9B0 576EB9B0
Explanation: I/O adapter hardware error detected
Failing Item:
v IOA
v AJDG301
Explanation: A port failure was detected on port 0 v Check the Product Activity Log for other entries that
indicate interface problems and work those
Failing Item: problems.
v FCPORT v Check the device firmware level and apply the latest
v FCIOA PTFs.
v FCDEV v Check for LIC logs with major code 2E00. Contact
your next level of support with the information you
v OPT_CLN
have gathered.
Problem determination: IPL the IOP to retry the
57743121 57743121
device identification process. If the error persists then
Explanation: A port failure was detected on port 1 contact your service provider.
Failing Item: Failing Item:
v PTFSRCH
57748300 57748300
Explanation: IOA hardware error or PCI bus error
577434FF 577434FF
Failing Item:
Explanation: Format in progress
v FCIOA
Response: The device indicated that a format is in
v ANYBRDG
progress. When the format is complete, the device
should be usable. No action is required. This reference v PTFSRCH
code is logged for information only. v OPT_CLN
57748131 57748131
57749903 57749903
Explanation: Recovered Fibre Channel interface error
on port 1 Explanation: Tape device information was logged.
Informational event, no service required.
Response: No action required. This reference code is
logged for information only.
5774B000 5774B000
5774C000 5774C000
Explanation: System log entry only, no service action
required
Response: No action is required. This reference code
is logged for information only.
5774C402 5774C402
Explanation: Licensed Internal Code error
Failing Item:
v PTFSRCH
Explanation: A port failure was detected on port 0 v Check the Product Activity Log for other entries that
indicate interface problems and work those
Failing Item: problems.
v FCPORT v Check the device firmware level and apply the latest
v FCIOA PTFs.
v FCDEV v Check for LIC logs with major code 2E00. Contact
your next level of support with the information you
v OPT_CLN
have gathered.
Problem determination: IPL the IOP to retry the
577D3121 577D3121
device identification process. If the error persists then
Explanation: A port failure was detected on port 1 contact your service provider.
Failing Item: Failing Item:
v PTFSRCH
577D8300 577D8300
Explanation: IOA hardware error or PCI bus error
577D34FF 577D34FF
Failing Item:
Explanation: Format in progress
v FCIOA
Response: The device indicated that a format is in
v ANYBRDG
progress. When the format is complete, the device
should be usable. No action is required. This reference v PTFSRCH
code is logged for information only. v OPT_CLN
577D8131 577D8131
577D9903 577D9903
Explanation: Recovered Fibre Channel interface error
on port 1 Explanation: Tape device information was logged.
Informational event, no service required.
Response: No action required. This reference code is
logged for information only.
577DB000 577DB000
577DC000 577DC000
Explanation: System log entry only, no service action
required
Response: No action is required. This reference code
is logged for information only.
577DC402 577DC402
Explanation: Licensed Internal Code error
Failing Item:
v PTFSRCH
v The embedded storage adapter on the I/O Card type 2BE1 (feature RAID enablement card for
backplane. embedded IOA) read the following: When working the
v The RAID enablement card. FRUs from the serviceable event or the failing item list
here, the embedded storage adapter (STORIOA) has
v The Battery charger and carrier card. three physical parts:
v The embedded storage adapter on the I/O
See symbolic FRU FEATCRD for the location codes of
backplane.
the FRUs if they are not listed in the serviceable event
or if you are working the failing item list here. v The RAID enablement card.
v The Battery charger and carrier card.
Card type 57CB (embedded IOA with 2BCF battery
card for embedded IOA) read the following: When See symbolic FRU FEATCRD for the location codes of
working the FRUs from the serviceable event or the the FRUs if they are not listed in the serviceable event
failing item list here, the embedded storage adapter or if you are working the failing item list here.
(STORIOA) has two physical parts:
Card type 57CB (embedded IOA with 2BCF battery v The RAID enablement card.
card for embedded IOA) read the following: When v The Battery charger and carrier card.
working the FRUs from the serviceable event or the
failing item list here, the embedded storage adapter See symbolic FRU FEATCRD for the location codes of
(STORIOA) has two physical parts: the FRUs if they are not listed in the serviceable event
v The embedded storage adapter on the I/O or if you are working the failing item list here.
backplane.
v The Battery charger and carrier card. Card type 57CB (embedded IOA with 2BCF battery
card) read the following: When working the FRUs from
See symbolic FRU FEATCRD for the location codes of the serviceable event or the failing item list here, the
the FRUs if they are not listed in the serviceable event embedded storage adapter (STORIOA) has two
or if you are working the failing item list here. physical parts:
v The embedded storage adapter on the I/O
Card type 57CF (embedded IOAs on DASD backplane backplane.
with 2BC2 dual battery charger and carrier card for the v The Battery charger and carrier card.
embedded IOAs) read the following: When working
the FRUs from the serviceable event or the failing item See symbolic FRU FEATCRD for the location codes of
list here, the embedded storage adapters (STORIOA) the FRUs if they are not listed in the serviceable event
have two physical parts: or if you are working the failing item list here.
v The embedded storage adapter on the DASD
backplane. Card type 57CF (embedded IOAs on DASD backplane
v The dual battery charger and carrier card. To with 2BC2 dual battery charger and carrier card) read
determine which battery is connected to which the following: When working the FRUs from the
embedded IOA use the bus number of the IOA with serviceable event or the failing item list here, the
symbolic FRU CACHBAT. embedded storage adapters (STORIOA) have two
physical parts:
See symbolic FRU FEATCRD for the location code of v The embedded storage adapter on the DASD
the dual battery charger and carrier card if it is not backplane.
listed in the serviceable event or if you are working the v The dual battery charger and carrier card. To
failing item list here. determine which battery is connected to which
Failing Item: embedded IOA use the bus number of the IOA with
symbolic FRU CACHBAT.
v BACKPLN
v STORIOA See symbolic FRU FEATCRD for the location code of
the dual battery charger and carrier card if it is not
57B38008 57B38008 listed in the serviceable event or if you are working the
failing item list here.
Explanation: A permanent cache battery pack failure
occurred Failing Item:
v CACHBAT
Response: Under a certain configuration, this SRC
may not represent an error that requires a service v STORIOA
action. Depending on the configuration of the system, v FEATCRD
the Storage IOA may have been altered and/or the
Storage IOA Cache may have been disabled to allow
attachment of OEM Storage that emulates a Load 57B38009 57B38009
Source drive. If this is the case, this error will be posted Explanation: Impending cache battery pack failure
each time the IOA is IPLed and it can be ignored.
Failing Item:
If you are working with one of the card types below,
v CACHBAT
the adapter has mulitple physical parts. Choose the
card type to identify the physical parts of the storage
adapter. 57B38100 57B38100
Card type 2BE1 (feature RAID enablement card for Explanation: Licensed Internal Code error
embedded IOA) read the following: When working the
Response: If you are working with one of the card
FRUs from the serviceable event or the failing item list
types below, the adapter has mulitple physical parts.
here, the embedded storage adapter (STORIOA) has
Choose the card type to identify the physical parts of
three physical parts:
the storage adapter.
v The embedded storage adapter on the I/O
backplane. Card type 2BE1 (feature RAID enablement card for
Card type 57CB (embedded IOA with 2BCF battery Card type 57CB (embedded IOA with 2BCF battery
card for embedded IOA) read the following: When card for embedded IOA) read the following: When
working the FRUs from the serviceable event or the working the FRUs from the serviceable event or the
failing item list here, the embedded storage adapter failing item list here, the embedded storage adapter
(STORIOA) has two physical parts: (STORIOA) has two physical parts:
v The embedded storage adapter on the I/O v The embedded storage adapter on the I/O
backplane. backplane.
v The Battery charger and carrier card. v The Battery charger and carrier card.
See symbolic FRU FEATCRD for the location codes of See symbolic FRU FEATCRD for the location codes of
the FRUs if they are not listed in the serviceable event the FRUs if they are not listed in the serviceable event
or if you are working the failing item list here. or if you are working the failing item list here.
Card type 57CF (embedded IOAs on DASD backplane Card type 57CF (embedded IOAs on DASD backplane
with 2BC2 dual battery charger and carrier card for the with 2BC2 dual battery charger and carrier card for the
embedded IOAs) read the following: When working embedded IOAs) read the following: When working
the FRUs from the serviceable event or the failing item the FRUs from the serviceable event or the failing item
list here, the embedded storage adapters (STORIOA) list here, the embedded storage adapters (STORIOA)
have two physical parts: have two physical parts:
v The embedded storage adapter on the DASD v The embedded storage adapter on the DASD
backplane. backplane.
v The dual battery charger and carrier card. To v The dual battery charger and carrier card. To
determine which battery is connected to which determine which battery is connected to which
embedded IOA use the bus number of the IOA with embedded IOA use the bus number of the IOA with
symbolic FRU CACHBAT. symbolic FRU CACHBAT.
See symbolic FRU FEATCRD for the location code of See symbolic FRU FEATCRD for the location code of
the dual battery charger and carrier card if it is not the dual battery charger and carrier card if it is not
listed in the serviceable event or if you are working the listed in the serviceable event or if you are working the
failing item list here. failing item list here.
Failing Item: Failing Item:
v STORIOA v PTFSRCH
v ANYBRDG v STORIOA
See symbolic FRU FEATCRD for the location codes of See symbolic FRU FEATCRD for the location codes of
the FRUs if they are not listed in the serviceable event the FRUs if they are not listed in the serviceable event
or if you are working the failing item list here. or if you are working the failing item list here.
Card type 57CB (embedded IOA with 2BCF battery Card type 57CB (embedded IOA with 2BCF battery
card for embedded IOA) read the following: When card for embedded IOA) read the following: When
working the FRUs from the serviceable event or the working the FRUs from the serviceable event or the
failing item list here, the embedded storage adapter failing item list here, the embedded storage adapter
(STORIOA) has two physical parts: (STORIOA) has two physical parts:
v The embedded storage adapter on the I/O v The embedded storage adapter on the I/O
backplane. backplane.
v The Battery charger and carrier card. v The Battery charger and carrier card.
See symbolic FRU FEATCRD for the location codes of See symbolic FRU FEATCRD for the location codes of
the FRUs if they are not listed in the serviceable event the FRUs if they are not listed in the serviceable event
or if you are working the failing item list here. or if you are working the failing item list here.
Card type 57CF (embedded IOAs on DASD backplane Card type 57CF (embedded IOAs on DASD backplane
with 2BC2 dual battery charger and carrier card for the with 2BC2 dual battery charger and carrier card for the
embedded IOAs) read the following: When working embedded IOAs) read the following: When working
the FRUs from the serviceable event or the failing item the FRUs from the serviceable event or the failing item
list here, the embedded storage adapters (STORIOA) list here, the embedded storage adapters (STORIOA)
have two physical parts: have two physical parts:
v The embedded storage adapter on the DASD v The embedded storage adapter on the DASD
backplane. backplane.
v The dual battery charger and carrier card. To v The dual battery charger and carrier card. To
determine which battery is connected to which determine which battery is connected to which
embedded IOA use the bus number of the IOA with embedded IOA use the bus number of the IOA with
symbolic FRU CACHBAT. symbolic FRU CACHBAT.
See symbolic FRU FEATCRD for the location code of See symbolic FRU FEATCRD for the location code of
the dual battery charger and carrier card if it is not the dual battery charger and carrier card if it is not
listed in the serviceable event or if you are working the listed in the serviceable event or if you are working the
failing item list here. failing item list here.
Failing Item: Failing Item:
v PTFSRCH v PTFSRCH
v STORIOA v STORIOA
v The embedded storage adapter on the I/O v The embedded storage adapter on the I/O
backplane. backplane.
v The RAID enablement card. v The RAID enablement card.
v The Battery charger and carrier card. v The Battery charger and carrier card.
See symbolic FRU FEATCRD for the location codes of See symbolic FRU FEATCRD for the location codes of
the FRUs if they are not listed in the serviceable event the FRUs if they are not listed in the serviceable event
or if you are working the failing item list here. or if you are working the failing item list here.
Card type 57CB (embedded IOA with 2BCF battery Card type 57CB (embedded IOA with 2BCF battery
card for embedded IOA) read the following: When card for embedded IOA) read the following: When
working the FRUs from the serviceable event or the working the FRUs from the serviceable event or the
failing item list here, the embedded storage adapter failing item list here, the embedded storage adapter
(STORIOA) has two physical parts: (STORIOA) has two physical parts:
v The embedded storage adapter on the I/O v The embedded storage adapter on the I/O
backplane. backplane.
v The Battery charger and carrier card. v The Battery charger and carrier card.
See symbolic FRU FEATCRD for the location codes of See symbolic FRU FEATCRD for the location codes of
the FRUs if they are not listed in the serviceable event the FRUs if they are not listed in the serviceable event
or if you are working the failing item list here. or if you are working the failing item list here.
Card type 57CF (embedded IOAs on DASD backplane Card type 57CF (embedded IOAs on DASD backplane
with 2BC2 dual battery charger and carrier card for the with 2BC2 dual battery charger and carrier card for the
embedded IOAs) read the following: When working embedded IOAs) read the following: When working
the FRUs from the serviceable event or the failing item the FRUs from the serviceable event or the failing item
list here, the embedded storage adapters (STORIOA) list here, the embedded storage adapters (STORIOA)
have two physical parts: have two physical parts:
v The embedded storage adapter on the DASD v The embedded storage adapter on the DASD
backplane. backplane.
v The dual battery charger and carrier card. To v The dual battery charger and carrier card. To
determine which battery is connected to which determine which battery is connected to which
embedded IOA use the bus number of the IOA with embedded IOA use the bus number of the IOA with
symbolic FRU CACHBAT. symbolic FRU CACHBAT.
See symbolic FRU FEATCRD for the location code of See symbolic FRU FEATCRD for the location code of
the dual battery charger and carrier card if it is not the dual battery charger and carrier card if it is not
listed in the serviceable event or if you are working the listed in the serviceable event or if you are working the
failing item list here. failing item list here.
Failing Item: Failing Item:
v SVCDOCS v STORIOA
v STORIOA v ANYBRDG
v PTFSRCH
57B38300 57B38300
Explanation: IOA hardware error or PCI bus error 57B38301 57B38301
Response: If you are working with one of the card Explanation: Not valid condition in Licensed Internal
types below, the adapter has mulitple physical parts. Code
Choose the card type to identify the physical parts of Response: If you are working with one of the card
the storage adapter. types below, the adapter has mulitple physical parts.
Card type 2BE1 (feature RAID enablement card for Choose the card type to identify the physical parts of
embedded IOA) read the following: When working the the storage adapter.
FRUs from the serviceable event or the failing item list Card type 2BE1 (feature RAID enablement card for
here, the embedded storage adapter (STORIOA) has embedded IOA) read the following: When working the
three physical parts: FRUs from the serviceable event or the failing item list
here, the embedded storage adapter (STORIOA) has FRUs from the serviceable event or the failing item list
three physical parts: here, the embedded storage adapter (STORIOA) has
v The embedded storage adapter on the I/O three physical parts:
backplane. v The embedded storage adapter on the I/O
v The RAID enablement card. backplane.
v The Battery charger and carrier card. v The RAID enablement card.
v The Battery charger and carrier card.
See symbolic FRU FEATCRD for the location codes of
the FRUs if they are not listed in the serviceable event See symbolic FRU FEATCRD for the location codes of
or if you are working the failing item list here. the FRUs if they are not listed in the serviceable event
or if you are working the failing item list here.
Card type 57CB (embedded IOA with 2BCF battery
card for embedded IOA) read the following: When Card type 57CB (embedded IOA with 2BCF battery
working the FRUs from the serviceable event or the card for embedded IOA) read the following: When
failing item list here, the embedded storage adapter working the FRUs from the serviceable event or the
(STORIOA) has two physical parts: failing item list here, the embedded storage adapter
v The embedded storage adapter on the I/O (STORIOA) has two physical parts:
backplane. v The embedded storage adapter on the I/O
v The Battery charger and carrier card. backplane.
v The Battery charger and carrier card.
See symbolic FRU FEATCRD for the location codes of
the FRUs if they are not listed in the serviceable event See symbolic FRU FEATCRD for the location codes of
or if you are working the failing item list here. the FRUs if they are not listed in the serviceable event
or if you are working the failing item list here.
Card type 57CF (embedded IOAs on DASD backplane
with 2BC2 dual battery charger and carrier card for the Card type 57CF (embedded IOAs on DASD backplane
embedded IOAs) read the following: When working with 2BC2 dual battery charger and carrier card for the
the FRUs from the serviceable event or the failing item embedded IOAs) read the following: When working
list here, the embedded storage adapters (STORIOA) the FRUs from the serviceable event or the failing item
have two physical parts: list here, the embedded storage adapters (STORIOA)
v The embedded storage adapter on the DASD have two physical parts:
backplane. v The embedded storage adapter on the DASD
v The dual battery charger and carrier card. To backplane.
determine which battery is connected to which v The dual battery charger and carrier card. To
embedded IOA use the bus number of the IOA with determine which battery is connected to which
symbolic FRU CACHBAT. embedded IOA use the bus number of the IOA with
symbolic FRU CACHBAT.
See symbolic FRU FEATCRD for the location code of
the dual battery charger and carrier card if it is not See symbolic FRU FEATCRD for the location code of
listed in the serviceable event or if you are working the the dual battery charger and carrier card if it is not
failing item list here. listed in the serviceable event or if you are working the
failing item list here.
Failing Item:
v PTFSRCH Failing Item:
v STORIOA v SVCDOCS
v STORIOA
57B38302 57B38302
57B38400 57B38400
Explanation: Missing Licensed Internal Code
Explanation: Licensed Internal Code error
Response: Ensure that the code necessary to support
this I/O adapter is loaded. Failing Item:
If you are working with one of the card types below, v PTFSRCH
the adapter has mulitple physical parts. Choose the
card type to identify the physical parts of the storage
adapter.
Card type 2BE1 (feature RAID enablement card for
embedded IOA) read the following: When working the
v FI01105
57B38404 57B38404
v STORIOA
Explanation: System log entry only. No service action
required.
57B39001 57B39001
See symbolic FRU FEATCRD for the location codes of Failing Item:
the FRUs if they are not listed in the serviceable event v NEXTLVL
or if you are working the failing item list here.
57B39020 57B39020
Card type 57CF (embedded IOAs on DASD backplane
with 2BC2 dual battery charger and carrier card for the Explanation: Two or more disk units missing from
embedded IOAs) read the following: When working RAID-5 or RAID-6 array
the FRUs from the serviceable event or the failing item
Failing Item:
list here, the embedded storage adapters (STORIOA)
have two physical parts: v SIP3111
v The embedded storage adapter on the DASD
backplane. 57B39021 57B39021
v The dual battery charger and carrier card. To Explanation: Two or more disk units missing from
determine which battery is connected to which RAID-5 or RAID-6 array
embedded IOA use the bus number of the IOA with
symbolic FRU CACHBAT. Failing Item:
v SIP3111
See symbolic FRU FEATCRD for the location code of
the dual battery charger and carrier card if it is not
listed in the serviceable event or if you are working the
failing item list here.
Failing Item:
Failing Item:
57B39031 57B39031
v SIP3110
v FI02112 Explanation: Automatic rebuild initiated for array
Response: Either a previous rebuild was interrupted
57B39026 57B39026 and was automatically restarted, or a hot spare disk
unit was used to automatically rebuild the array. Look
Explanation: Disk unit not found at required physical for other reference codes and take action on them.
location
Response: A previously exposed disk unit in an array 57B39032 57B39032
was not found at the required physical location.
Explanation: A disk unit in an array is missing or
Failing Item: failed
v NEXTLVL
Response: The array is still protected, but the disk
unit should be replaced.
57B39027 57B39027
Failing Item:
Explanation: Array not functional due to parity out of v SIP3110
synchronization
v FI02112
Response: Array is or would become exposed and
parity data is out of synchronization
57B39040 57B39040
Failing Item:
Explanation: Re-synchronization of array parity was
v SIP3113 initiated
Response: No action required.
v The embedded storage adapter on the I/O v The embedded storage adapter on the I/O
backplane. backplane.
v The RAID enablement card. v The RAID enablement card.
v The Battery charger and carrier card. v The Battery charger and carrier card.
See symbolic FRU FEATCRD for the location codes of See symbolic FRU FEATCRD for the location codes of
the FRUs if they are not listed in the serviceable event the FRUs if they are not listed in the serviceable event
or if you are working the failing item list here. or if you are working the failing item list here.
Card type 57CB (embedded IOA with 2BCF battery Card type 57CB (embedded IOA with 2BCF battery
card for embedded IOA) read the following: When card for embedded IOA) read the following: When
working the FRUs from the serviceable event or the working the FRUs from the serviceable event or the
failing item list here, the embedded storage adapter failing item list here, the embedded storage adapter
(STORIOA) has two physical parts: (STORIOA) has two physical parts:
v The embedded storage adapter on the I/O v The embedded storage adapter on the I/O
backplane. backplane.
v The Battery charger and carrier card. v The Battery charger and carrier card.
See symbolic FRU FEATCRD for the location codes of See symbolic FRU FEATCRD for the location codes of
the FRUs if they are not listed in the serviceable event the FRUs if they are not listed in the serviceable event
or if you are working the failing item list here. or if you are working the failing item list here.
Card type 57CF (embedded IOAs on DASD backplane Card type 57CF (embedded IOAs on DASD backplane
with 2BC2 dual battery charger and carrier card for the with 2BC2 dual battery charger and carrier card for the
embedded IOAs) read the following: When working embedded IOAs) read the following: When working
the FRUs from the serviceable event or the failing item the FRUs from the serviceable event or the failing item
list here, the embedded storage adapters (STORIOA) list here, the embedded storage adapters (STORIOA)
have two physical parts: have two physical parts:
v The embedded storage adapter on the DASD v The embedded storage adapter on the DASD
backplane. backplane.
v The dual battery charger and carrier card. To v The dual battery charger and carrier card. To
determine which battery is connected to which determine which battery is connected to which
embedded IOA use the bus number of the IOA with embedded IOA use the bus number of the IOA with
symbolic FRU CACHBAT. symbolic FRU CACHBAT.
See symbolic FRU FEATCRD for the location code of See symbolic FRU FEATCRD for the location code of
the dual battery charger and carrier card if it is not the dual battery charger and carrier card if it is not
listed in the serviceable event or if you are working the listed in the serviceable event or if you are working the
failing item list here. failing item list here.
Failing Item: Failing Item:
v FI01105 v FI01105
v STORIOA v STORIOA
If you cannot resolve the problem, contact your next Explanation: I/O adapter detected a recoverable error
level of support. Response: If you are working with one of the card
Failing Item: types below, the adapter has mulitple physical parts.
Choose the card type to identify the physical parts of
v SVCDOCS
the storage adapter.
Card type 2BE1 (feature RAID enablement card for
57B39091 57B39091
embedded IOA) read the following: When working the
Explanation: Incorrect hardware configuration change FRUs from the serviceable event or the failing item list
detected here, the embedded storage adapter (STORIOA) has
three physical parts:
Response: Use Hardware Service Manager to re-IPL
the virtual I/O processor that is associated with this v The embedded storage adapter on the I/O
I/O adapter. Other resources attached to the virtual backplane.
I/O processor may then need to be Varied On. v The RAID enablement card.
If any reference codes are surfaced, use the new v The Battery charger and carrier card.
reference code to resolve the problem.
See symbolic FRU FEATCRD for the location codes of
If you cannot resolve the problem, contact your next the FRUs if they are not listed in the serviceable event
level of support. or if you are working the failing item list here.
Failing Item:
Card type 57CB (embedded IOA with 2BCF battery
v SVCDOCS
card for embedded IOA) read the following: When
working the FRUs from the serviceable event or the
57B39092 57B39092 failing item list here, the embedded storage adapter
(STORIOA) has two physical parts:
Explanation: Disk unit requires initialization before
use. v The embedded storage adapter on the I/O
backplane.
Failing Item:
v The Battery charger and carrier card.
v SIP3134
See symbolic FRU FEATCRD for the location codes of
57B39500 57B39500 the FRUs if they are not listed in the serviceable event
or if you are working the failing item list here.
Explanation: Internal program error in driver code.
Failing Item: Card type 57CF (embedded IOAs on DASD backplane
with 2BC2 dual battery charger and carrier card for the
v PTFSRCH
embedded IOAs) read the following: When working
the FRUs from the serviceable event or the failing item
57B39903 57B39903 list here, the embedded storage adapters (STORIOA)
have two physical parts:
Explanation: Tape device information was logged.
Informational event, no service required. v The embedded storage adapter on the DASD
backplane.
v The dual battery charger and carrier card. To
57B3C000 57B3C000 determine which battery is connected to which
Explanation: System log entry only. No service action embedded IOA use the bus number of the IOA with
required. symbolic FRU CACHBAT.
Explanation: I/O adapter detected recoverable bus SVCDOCS, then do NOT replace the I/O adapter. This
error is a recoverable error. Use Hardware Service Manager
to re-IPL the virtual I/O processor that is associated
Response: If this event appears in a serviceable event
with this I/O adapter.
view, work with the failing item list found there. If this
event does not appear in a serviceable event view, no Failing Item:
service action is required. v SVCDOCS
Failing Item:
v PRIMIOA 57B78300 57B78300
v AUXIOA Explanation: IOA hardware or PCI bus error
v BACKPLN
Failing Item:
v AUXIOA
57B78150 57B78150
v ANYBRDG
Explanation: A permanent failure occurred v PTFSRCH
Response: NOTE: Under a certain configuration, this
SRC may not represent an error that requires a service 57B78301 57B78301
action. Depending on the configuration of the system,
the Storage IOA may have been altered and/or the Explanation: Not valid condition in Licensed Internal
Storage IOA Cache may have been disabled to allow Code
attachment of OEM Storage that emulates a Load Failing Item:
Source drive. If this is the case, this error will be posted
each time the IOA is IPLed and it can be ignored. v PTFSRCH
v AUXIOA
Failing Item:
v AUXIOA
57B78302 57B78302
v ANYBRDG
Explanation: Missing Licensed Internal Code
57B78151 57B78151 Response: Ensure that the code necessary to support
this I/O adapter is loaded.
Explanation: Licensed Internal Code error
Failing Item:
Failing Item:
v SVCDOCS
v PTFSRCH
v AUXIOA
v AUXIOA
57B79055 57B79055
57B78155 57B78155
Explanation: Write cache data is available for attached
Explanation: A permanent failure occurred storage IOA
Failing Item: Response: No service action required.
v PTFSRCH
v AUXIOA 57B79071 57B79071
Explanation: Link from IOA to auxiliary cache IOA
57B78156 57B78156 went operational
Explanation: A permanent failure occurred Response: No service action required.
Failing Item:
v PTFSRCH 57B79072 57B79072
v AUXIOA Explanation: Link from IOA to auxiliary cache IOA
went non-operational
57B78157 57B78157 Response: No service action required.
Explanation: I/O adapter card error
Response: Display the Service Action Log entry for
this SRC. If the Failing Item indicates I/O adapter, then
replace the I/O adapter. If the Failing Item indicates
57B79073 57B79073
Explanation: Multiple I/O adapters connected in a not
valid configuration
Failing Item:
v SIP3140
57B79076 57B79076
Explanation: Missing remote I/O adapter
Failing Item:
v SIP3147
v PRIMIOA
v AUXIOA
v BACKPLN
57B7FF3D 57B7FF3D
Explanation: I/O adapter detected recoverable error
Response: If this event appears in a serviceable event
view, work with the failing item list found there. If this
event does not appear in a serviceable event view, no
service action is required.
Failing Item:
v AUXIOA
v ANYBRDG
v The embedded storage adapter on the I/O Card type 2BE1 (feature RAID enablement card for
backplane. embedded IOA) read the following: When working the
v The RAID enablement card. FRUs from the serviceable event or the failing item list
here, the embedded storage adapter (STORIOA) has
v The Battery charger and carrier card. three physical parts:
v The embedded storage adapter on the I/O
See symbolic FRU FEATCRD for the location codes of
backplane.
the FRUs if they are not listed in the serviceable event
or if you are working the failing item list here. v The RAID enablement card.
v The Battery charger and carrier card.
Card type 57CB (embedded IOA with 2BCF battery
card for embedded IOA) read the following: When See symbolic FRU FEATCRD for the location codes of
working the FRUs from the serviceable event or the the FRUs if they are not listed in the serviceable event
failing item list here, the embedded storage adapter or if you are working the failing item list here.
(STORIOA) has two physical parts:
Card type 57CB (embedded IOA with 2BCF battery v The RAID enablement card.
card for embedded IOA) read the following: When v The Battery charger and carrier card.
working the FRUs from the serviceable event or the
failing item list here, the embedded storage adapter See symbolic FRU FEATCRD for the location codes of
(STORIOA) has two physical parts: the FRUs if they are not listed in the serviceable event
v The embedded storage adapter on the I/O or if you are working the failing item list here.
backplane.
v The Battery charger and carrier card. Card type 57CB (embedded IOA with 2BCF battery
card) read the following: When working the FRUs from
See symbolic FRU FEATCRD for the location codes of the serviceable event or the failing item list here, the
the FRUs if they are not listed in the serviceable event embedded storage adapter (STORIOA) has two
or if you are working the failing item list here. physical parts:
v The embedded storage adapter on the I/O
Card type 57CF (embedded IOAs on DASD backplane backplane.
with 2BC2 dual battery charger and carrier card for the v The Battery charger and carrier card.
embedded IOAs) read the following: When working
the FRUs from the serviceable event or the failing item See symbolic FRU FEATCRD for the location codes of
list here, the embedded storage adapters (STORIOA) the FRUs if they are not listed in the serviceable event
have two physical parts: or if you are working the failing item list here.
v The embedded storage adapter on the DASD
backplane. Card type 57CF (embedded IOAs on DASD backplane
v The dual battery charger and carrier card. To with 2BC2 dual battery charger and carrier card) read
determine which battery is connected to which the following: When working the FRUs from the
embedded IOA use the bus number of the IOA with serviceable event or the failing item list here, the
symbolic FRU CACHBAT. embedded storage adapters (STORIOA) have two
physical parts:
See symbolic FRU FEATCRD for the location code of v The embedded storage adapter on the DASD
the dual battery charger and carrier card if it is not backplane.
listed in the serviceable event or if you are working the v The dual battery charger and carrier card. To
failing item list here. determine which battery is connected to which
Failing Item: embedded IOA use the bus number of the IOA with
symbolic FRU CACHBAT.
v BACKPLN
v STORIOA See symbolic FRU FEATCRD for the location code of
the dual battery charger and carrier card if it is not
57B88008 57B88008 listed in the serviceable event or if you are working the
failing item list here.
Explanation: A permanent cache battery pack failure
occurred Failing Item:
v CACHBAT
Response: Under a certain configuration, this SRC
may not represent an error that requires a service v STORIOA
action. Depending on the configuration of the system, v FEATCRD
the Storage IOA may have been altered and/or the
Storage IOA Cache may have been disabled to allow
attachment of OEM Storage that emulates a Load 57B88009 57B88009
Source drive. If this is the case, this error will be posted Explanation: Impending cache battery pack failure
each time the IOA is IPLed and it can be ignored.
Failing Item:
If you are working with one of the card types below,
v CACHBAT
the adapter has mulitple physical parts. Choose the
card type to identify the physical parts of the storage
adapter. 57B88100 57B88100
Card type 2BE1 (feature RAID enablement card for Explanation: Licensed Internal Code error
embedded IOA) read the following: When working the
Response: If you are working with one of the card
FRUs from the serviceable event or the failing item list
types below, the adapter has mulitple physical parts.
here, the embedded storage adapter (STORIOA) has
Choose the card type to identify the physical parts of
three physical parts:
the storage adapter.
v The embedded storage adapter on the I/O
backplane. Card type 2BE1 (feature RAID enablement card for
Card type 57CB (embedded IOA with 2BCF battery Card type 57CB (embedded IOA with 2BCF battery
card for embedded IOA) read the following: When card for embedded IOA) read the following: When
working the FRUs from the serviceable event or the working the FRUs from the serviceable event or the
failing item list here, the embedded storage adapter failing item list here, the embedded storage adapter
(STORIOA) has two physical parts: (STORIOA) has two physical parts:
v The embedded storage adapter on the I/O v The embedded storage adapter on the I/O
backplane. backplane.
v The Battery charger and carrier card. v The Battery charger and carrier card.
See symbolic FRU FEATCRD for the location codes of See symbolic FRU FEATCRD for the location codes of
the FRUs if they are not listed in the serviceable event the FRUs if they are not listed in the serviceable event
or if you are working the failing item list here. or if you are working the failing item list here.
Card type 57CF (embedded IOAs on DASD backplane Card type 57CF (embedded IOAs on DASD backplane
with 2BC2 dual battery charger and carrier card for the with 2BC2 dual battery charger and carrier card for the
embedded IOAs) read the following: When working embedded IOAs) read the following: When working
the FRUs from the serviceable event or the failing item the FRUs from the serviceable event or the failing item
list here, the embedded storage adapters (STORIOA) list here, the embedded storage adapters (STORIOA)
have two physical parts: have two physical parts:
v The embedded storage adapter on the DASD v The embedded storage adapter on the DASD
backplane. backplane.
v The dual battery charger and carrier card. To v The dual battery charger and carrier card. To
determine which battery is connected to which determine which battery is connected to which
embedded IOA use the bus number of the IOA with embedded IOA use the bus number of the IOA with
symbolic FRU CACHBAT. symbolic FRU CACHBAT.
See symbolic FRU FEATCRD for the location code of See symbolic FRU FEATCRD for the location code of
the dual battery charger and carrier card if it is not the dual battery charger and carrier card if it is not
listed in the serviceable event or if you are working the listed in the serviceable event or if you are working the
failing item list here. failing item list here.
Failing Item: Failing Item:
v STORIOA v PTFSRCH
v ANYBRDG v STORIOA
See symbolic FRU FEATCRD for the location codes of See symbolic FRU FEATCRD for the location codes of
the FRUs if they are not listed in the serviceable event the FRUs if they are not listed in the serviceable event
or if you are working the failing item list here. or if you are working the failing item list here.
Card type 57CB (embedded IOA with 2BCF battery Card type 57CB (embedded IOA with 2BCF battery
card for embedded IOA) read the following: When card for embedded IOA) read the following: When
working the FRUs from the serviceable event or the working the FRUs from the serviceable event or the
failing item list here, the embedded storage adapter failing item list here, the embedded storage adapter
(STORIOA) has two physical parts: (STORIOA) has two physical parts:
v The embedded storage adapter on the I/O v The embedded storage adapter on the I/O
backplane. backplane.
v The Battery charger and carrier card. v The Battery charger and carrier card.
See symbolic FRU FEATCRD for the location codes of See symbolic FRU FEATCRD for the location codes of
the FRUs if they are not listed in the serviceable event the FRUs if they are not listed in the serviceable event
or if you are working the failing item list here. or if you are working the failing item list here.
Card type 57CF (embedded IOAs on DASD backplane Card type 57CF (embedded IOAs on DASD backplane
with 2BC2 dual battery charger and carrier card for the with 2BC2 dual battery charger and carrier card for the
embedded IOAs) read the following: When working embedded IOAs) read the following: When working
the FRUs from the serviceable event or the failing item the FRUs from the serviceable event or the failing item
list here, the embedded storage adapters (STORIOA) list here, the embedded storage adapters (STORIOA)
have two physical parts: have two physical parts:
v The embedded storage adapter on the DASD v The embedded storage adapter on the DASD
backplane. backplane.
v The dual battery charger and carrier card. To v The dual battery charger and carrier card. To
determine which battery is connected to which determine which battery is connected to which
embedded IOA use the bus number of the IOA with embedded IOA use the bus number of the IOA with
symbolic FRU CACHBAT. symbolic FRU CACHBAT.
See symbolic FRU FEATCRD for the location code of See symbolic FRU FEATCRD for the location code of
the dual battery charger and carrier card if it is not the dual battery charger and carrier card if it is not
listed in the serviceable event or if you are working the listed in the serviceable event or if you are working the
failing item list here. failing item list here.
Failing Item: Failing Item:
v PTFSRCH v PTFSRCH
v STORIOA v STORIOA
v The embedded storage adapter on the I/O v The embedded storage adapter on the I/O
backplane. backplane.
v The RAID enablement card. v The RAID enablement card.
v The Battery charger and carrier card. v The Battery charger and carrier card.
See symbolic FRU FEATCRD for the location codes of See symbolic FRU FEATCRD for the location codes of
the FRUs if they are not listed in the serviceable event the FRUs if they are not listed in the serviceable event
or if you are working the failing item list here. or if you are working the failing item list here.
Card type 57CB (embedded IOA with 2BCF battery Card type 57CB (embedded IOA with 2BCF battery
card for embedded IOA) read the following: When card for embedded IOA) read the following: When
working the FRUs from the serviceable event or the working the FRUs from the serviceable event or the
failing item list here, the embedded storage adapter failing item list here, the embedded storage adapter
(STORIOA) has two physical parts: (STORIOA) has two physical parts:
v The embedded storage adapter on the I/O v The embedded storage adapter on the I/O
backplane. backplane.
v The Battery charger and carrier card. v The Battery charger and carrier card.
See symbolic FRU FEATCRD for the location codes of See symbolic FRU FEATCRD for the location codes of
the FRUs if they are not listed in the serviceable event the FRUs if they are not listed in the serviceable event
or if you are working the failing item list here. or if you are working the failing item list here.
Card type 57CF (embedded IOAs on DASD backplane Card type 57CF (embedded IOAs on DASD backplane
with 2BC2 dual battery charger and carrier card for the with 2BC2 dual battery charger and carrier card for the
embedded IOAs) read the following: When working embedded IOAs) read the following: When working
the FRUs from the serviceable event or the failing item the FRUs from the serviceable event or the failing item
list here, the embedded storage adapters (STORIOA) list here, the embedded storage adapters (STORIOA)
have two physical parts: have two physical parts:
v The embedded storage adapter on the DASD v The embedded storage adapter on the DASD
backplane. backplane.
v The dual battery charger and carrier card. To v The dual battery charger and carrier card. To
determine which battery is connected to which determine which battery is connected to which
embedded IOA use the bus number of the IOA with embedded IOA use the bus number of the IOA with
symbolic FRU CACHBAT. symbolic FRU CACHBAT.
See symbolic FRU FEATCRD for the location code of See symbolic FRU FEATCRD for the location code of
the dual battery charger and carrier card if it is not the dual battery charger and carrier card if it is not
listed in the serviceable event or if you are working the listed in the serviceable event or if you are working the
failing item list here. failing item list here.
Failing Item: Failing Item:
v SVCDOCS v STORIOA
v STORIOA v ANYBRDG
v PTFSRCH
57B88300 57B88300
Explanation: IOA hardware error or PCI bus error 57B88301 57B88301
Response: If you are working with one of the card Explanation: Not valid condition in Licensed Internal
types below, the adapter has mulitple physical parts. Code
Choose the card type to identify the physical parts of Response: If you are working with one of the card
the storage adapter. types below, the adapter has mulitple physical parts.
Card type 2BE1 (feature RAID enablement card for Choose the card type to identify the physical parts of
embedded IOA) read the following: When working the the storage adapter.
FRUs from the serviceable event or the failing item list Card type 2BE1 (feature RAID enablement card for
here, the embedded storage adapter (STORIOA) has embedded IOA) read the following: When working the
three physical parts: FRUs from the serviceable event or the failing item list
here, the embedded storage adapter (STORIOA) has FRUs from the serviceable event or the failing item list
three physical parts: here, the embedded storage adapter (STORIOA) has
v The embedded storage adapter on the I/O three physical parts:
backplane. v The embedded storage adapter on the I/O
v The RAID enablement card. backplane.
v The Battery charger and carrier card. v The RAID enablement card.
v The Battery charger and carrier card.
See symbolic FRU FEATCRD for the location codes of
the FRUs if they are not listed in the serviceable event See symbolic FRU FEATCRD for the location codes of
or if you are working the failing item list here. the FRUs if they are not listed in the serviceable event
or if you are working the failing item list here.
Card type 57CB (embedded IOA with 2BCF battery
card for embedded IOA) read the following: When Card type 57CB (embedded IOA with 2BCF battery
working the FRUs from the serviceable event or the card for embedded IOA) read the following: When
failing item list here, the embedded storage adapter working the FRUs from the serviceable event or the
(STORIOA) has two physical parts: failing item list here, the embedded storage adapter
v The embedded storage adapter on the I/O (STORIOA) has two physical parts:
backplane. v The embedded storage adapter on the I/O
v The Battery charger and carrier card. backplane.
v The Battery charger and carrier card.
See symbolic FRU FEATCRD for the location codes of
the FRUs if they are not listed in the serviceable event See symbolic FRU FEATCRD for the location codes of
or if you are working the failing item list here. the FRUs if they are not listed in the serviceable event
or if you are working the failing item list here.
Card type 57CF (embedded IOAs on DASD backplane
with 2BC2 dual battery charger and carrier card for the Card type 57CF (embedded IOAs on DASD backplane
embedded IOAs) read the following: When working with 2BC2 dual battery charger and carrier card for the
the FRUs from the serviceable event or the failing item embedded IOAs) read the following: When working
list here, the embedded storage adapters (STORIOA) the FRUs from the serviceable event or the failing item
have two physical parts: list here, the embedded storage adapters (STORIOA)
v The embedded storage adapter on the DASD have two physical parts:
backplane. v The embedded storage adapter on the DASD
v The dual battery charger and carrier card. To backplane.
determine which battery is connected to which v The dual battery charger and carrier card. To
embedded IOA use the bus number of the IOA with determine which battery is connected to which
symbolic FRU CACHBAT. embedded IOA use the bus number of the IOA with
symbolic FRU CACHBAT.
See symbolic FRU FEATCRD for the location code of
the dual battery charger and carrier card if it is not See symbolic FRU FEATCRD for the location code of
listed in the serviceable event or if you are working the the dual battery charger and carrier card if it is not
failing item list here. listed in the serviceable event or if you are working the
failing item list here.
Failing Item:
v PTFSRCH Failing Item:
v STORIOA v SVCDOCS
v STORIOA
57B88302 57B88302
57B88400 57B88400
Explanation: Missing Licensed Internal Code
Explanation: Licensed Internal Code error
Response: Ensure that the code necessary to support
this I/O adapter is loaded. Failing Item:
If you are working with one of the card types below, v PTFSRCH
the adapter has mulitple physical parts. Choose the
card type to identify the physical parts of the storage
adapter.
Card type 2BE1 (feature RAID enablement card for
embedded IOA) read the following: When working the
v FI01105
57B88404 57B88404
v STORIOA
Explanation: System log entry only. No service action
required.
57B89001 57B89001
See symbolic FRU FEATCRD for the location codes of Failing Item:
the FRUs if they are not listed in the serviceable event v NEXTLVL
or if you are working the failing item list here.
57B89020 57B89020
Card type 57CF (embedded IOAs on DASD backplane
with 2BC2 dual battery charger and carrier card for the Explanation: Two or more disk units missing from
embedded IOAs) read the following: When working RAID-5 or RAID-6 array
the FRUs from the serviceable event or the failing item
Failing Item:
list here, the embedded storage adapters (STORIOA)
have two physical parts: v SIP3111
v The embedded storage adapter on the DASD
backplane. 57B89021 57B89021
v The dual battery charger and carrier card. To Explanation: Two or more disk units missing from
determine which battery is connected to which RAID-5 or RAID-6 array
embedded IOA use the bus number of the IOA with
symbolic FRU CACHBAT. Failing Item:
v SIP3111
See symbolic FRU FEATCRD for the location code of
the dual battery charger and carrier card if it is not
listed in the serviceable event or if you are working the
failing item list here.
Failing Item:
Failing Item:
57B89031 57B89031
v SIP3110
v FI02112 Explanation: Automatic rebuild initiated for array
Response: Either a previous rebuild was interrupted
57B89026 57B89026 and was automatically restarted, or a hot spare disk
unit was used to automatically rebuild the array. Look
Explanation: Disk unit not found at required physical for other reference codes and take action on them.
location
Response: A previously exposed disk unit in an array 57B89032 57B89032
was not found at the required physical location.
Explanation: A disk unit in an array is missing or
Failing Item: failed
v NEXTLVL
Response: The array is still protected, but the disk
unit should be replaced.
57B89027 57B89027
Failing Item:
Explanation: Array not functional due to parity out of v SIP3110
synchronization
v FI02112
Response: Array is or would become exposed and
parity data is out of synchronization
57B89040 57B89040
Failing Item:
Explanation: Re-synchronization of array parity was
v SIP3113 initiated
Response: No action required.
v The embedded storage adapter on the I/O v The embedded storage adapter on the I/O
backplane. backplane.
v The RAID enablement card. v The RAID enablement card.
v The Battery charger and carrier card. v The Battery charger and carrier card.
See symbolic FRU FEATCRD for the location codes of See symbolic FRU FEATCRD for the location codes of
the FRUs if they are not listed in the serviceable event the FRUs if they are not listed in the serviceable event
or if you are working the failing item list here. or if you are working the failing item list here.
Card type 57CB (embedded IOA with 2BCF battery Card type 57CB (embedded IOA with 2BCF battery
card for embedded IOA) read the following: When card for embedded IOA) read the following: When
working the FRUs from the serviceable event or the working the FRUs from the serviceable event or the
failing item list here, the embedded storage adapter failing item list here, the embedded storage adapter
(STORIOA) has two physical parts: (STORIOA) has two physical parts:
v The embedded storage adapter on the I/O v The embedded storage adapter on the I/O
backplane. backplane.
v The Battery charger and carrier card. v The Battery charger and carrier card.
See symbolic FRU FEATCRD for the location codes of See symbolic FRU FEATCRD for the location codes of
the FRUs if they are not listed in the serviceable event the FRUs if they are not listed in the serviceable event
or if you are working the failing item list here. or if you are working the failing item list here.
Card type 57CF (embedded IOAs on DASD backplane Card type 57CF (embedded IOAs on DASD backplane
with 2BC2 dual battery charger and carrier card for the with 2BC2 dual battery charger and carrier card for the
embedded IOAs) read the following: When working embedded IOAs) read the following: When working
the FRUs from the serviceable event or the failing item the FRUs from the serviceable event or the failing item
list here, the embedded storage adapters (STORIOA) list here, the embedded storage adapters (STORIOA)
have two physical parts: have two physical parts:
v The embedded storage adapter on the DASD v The embedded storage adapter on the DASD
backplane. backplane.
v The dual battery charger and carrier card. To v The dual battery charger and carrier card. To
determine which battery is connected to which determine which battery is connected to which
embedded IOA use the bus number of the IOA with embedded IOA use the bus number of the IOA with
symbolic FRU CACHBAT. symbolic FRU CACHBAT.
See symbolic FRU FEATCRD for the location code of See symbolic FRU FEATCRD for the location code of
the dual battery charger and carrier card if it is not the dual battery charger and carrier card if it is not
listed in the serviceable event or if you are working the listed in the serviceable event or if you are working the
failing item list here. failing item list here.
Failing Item: Failing Item:
v FI01105 v FI01105
v STORIOA v STORIOA
If you cannot resolve the problem, contact your next Explanation: I/O adapter detected a recoverable error
level of support. Response: If you are working with one of the card
Failing Item: types below, the adapter has mulitple physical parts.
Choose the card type to identify the physical parts of
v SVCDOCS
the storage adapter.
Card type 2BE1 (feature RAID enablement card for
57B89091 57B89091
embedded IOA) read the following: When working the
Explanation: Incorrect hardware configuration change FRUs from the serviceable event or the failing item list
detected here, the embedded storage adapter (STORIOA) has
three physical parts:
Response: Use Hardware Service Manager to re-IPL
the virtual I/O processor that is associated with this v The embedded storage adapter on the I/O
I/O adapter. Other resources attached to the virtual backplane.
I/O processor may then need to be Varied On. v The RAID enablement card.
If any reference codes are surfaced, use the new v The Battery charger and carrier card.
reference code to resolve the problem.
See symbolic FRU FEATCRD for the location codes of
If you cannot resolve the problem, contact your next the FRUs if they are not listed in the serviceable event
level of support. or if you are working the failing item list here.
Failing Item:
Card type 57CB (embedded IOA with 2BCF battery
v SVCDOCS
card for embedded IOA) read the following: When
working the FRUs from the serviceable event or the
57B89092 57B89092 failing item list here, the embedded storage adapter
(STORIOA) has two physical parts:
Explanation: Disk unit requires initialization before
use. v The embedded storage adapter on the I/O
backplane.
Failing Item:
v The Battery charger and carrier card.
v SIP3134
See symbolic FRU FEATCRD for the location codes of
57B89500 57B89500 the FRUs if they are not listed in the serviceable event
or if you are working the failing item list here.
Explanation: Internal program error in driver code.
Failing Item: Card type 57CF (embedded IOAs on DASD backplane
with 2BC2 dual battery charger and carrier card for the
v PTFSRCH
embedded IOAs) read the following: When working
the FRUs from the serviceable event or the failing item
57B89903 57B89903 list here, the embedded storage adapters (STORIOA)
have two physical parts:
Explanation: Tape device information was logged.
Informational event, no service required. v The embedded storage adapter on the DASD
backplane.
v The dual battery charger and carrier card. To
57B8C000 57B8C000 determine which battery is connected to which
Explanation: System log entry only. No service action embedded IOA use the bus number of the IOA with
required. symbolic FRU CACHBAT.
v The embedded storage adapter on the I/O contact your service provider.
backplane.
Failing Item:
v The Battery charger and carrier card.
v PTFSRCH
See symbolic FRU FEATCRD for the location codes of
the FRUs if they are not listed in the serviceable event 57C734FF 57C734FF
or if you are working the failing item list here.
Explanation: Format in progress
Card type 57CF (embedded IOAs on DASD backplane Response: No action required. This reference code is
with 2BC2 dual battery charger and carrier card). When logged for information only.
working the FRUs from the serviceable event or the
failing item list here, the embedded storage adapters
57C73601 57C73601
(STORIOA) have two physical parts:
v The embedded storage adapter on the DASD Explanation: System log entry only. No service action
backplane. required.
v The dual battery charger and carrier card. To
determine which battery is connected to which 57C74010 57C74010
embedded IOA use the bus number of the IOA with
symbolic FRU CACHBAT. Explanation: Configuration error
Response: Incorrect connection between cascaded
See symbolic FRU FEATCRD for the location code of enclosures.
the dual battery charger and carrier card if it is not
listed in the serviceable event or if you are working the Failing Item:
failing item list here. v SIP3142
Failing Item:
v SIP4050 57C74020 57C74020
v SIP4053 v DEVBPLN
v SASCABL v STORIOA
v SASEXP v FI01105
Explanation: Multipath redundancy level increased Explanation: Temporary device bus fabric error
Explanation: System log entry only. No service action Explanation: Unsupported enclosure function detected
required.
Failing Item:
v SIP3145
57C74100 57C74100
Explanation: Device bus fabric error 57C74150 57C74150
Response: If you are working with one of the card Explanation: I/O adapter detected PCI bus error
types below, the adapter has mulitple physical parts.
Choose the card type to identify the physical parts of Response: If this event appears in a serviceable event
the storage adapter. view, work with the failing item list found there. If this
event does not appear in a serviceable event view, no
Card type 57CB (embedded IOA with 2BCF battery service action is required.
card for embedded IOA) read the following: When
working the FRUs from the serviceable event or the If you are working with one of the card types below,
failing item list here, the embedded storage adapter the adapter has mulitple physical parts. Choose the
(STORIOA) has two physical parts: card type to identify the physical parts of the storage
adapter.
v The embedded storage adapter on the I/O
backplane. Card type 2BE1 (feature RAID enablement card for
v The Battery charger and carrier card. embedded IOA) read the following: When working the
FRUs from the serviceable event or the failing item list
See symbolic FRU FEATCRD for the location codes of here, the embedded storage adapter (STORIOA) has
the FRUs if they are not listed in the serviceable event three physical parts:
or if you are working the failing item list here. v The embedded storage adapter on the I/O
backplane.
Card type 57CF (embedded IOAs on DASD backplane v The RAID enablement card.
with 2BC2 dual battery charger and carrier card for the v The Battery charger and carrier card.
embedded IOAs) read the following: When working
the FRUs from the serviceable event or the failing item
list here, the embedded storage adapters (STORIOA)
have two physical parts:
See symbolic FRU FEATCRD for the location codes of v The RAID enablement card.
the FRUs if they are not listed in the serviceable event v The Battery charger and carrier card.
or if you are working the failing item list here.
See symbolic FRU FEATCRD for the location codes of
Card type 57CB (embedded IOA with 2BCF battery the FRUs if they are not listed in the serviceable event
card for embedded IOA) read the following: When or if you are working the failing item list here.
working the FRUs from the serviceable event or the
failing item list here, the embedded storage adapter Card type 57CB (embedded IOA with 2BCF battery
(STORIOA) has two physical parts: card for embedded IOA) read the following: When
v The embedded storage adapter on the I/O working the FRUs from the serviceable event or the
backplane. failing item list here, the embedded storage adapter
v The Battery charger and carrier card. (STORIOA) has two physical parts:
v The embedded storage adapter on the I/O
See symbolic FRU FEATCRD for the location codes of backplane.
the FRUs if they are not listed in the serviceable event v The Battery charger and carrier card.
or if you are working the failing item list here.
See symbolic FRU FEATCRD for the location codes of
Card type 57CF (embedded IOAs on DASD backplane the FRUs if they are not listed in the serviceable event
with 2BC2 dual battery charger and carrier card for the or if you are working the failing item list here.
embedded IOAs) read the following: When working
the FRUs from the serviceable event or the failing item Card type 57CF (embedded IOAs on DASD backplane
list here, the embedded storage adapters (STORIOA) with 2BC2 dual battery charger and carrier card for the
have two physical parts: embedded IOAs) read the following: When working
v The embedded storage adapter on the DASD the FRUs from the serviceable event or the failing item
backplane. list here, the embedded storage adapters (STORIOA)
v The dual battery charger and carrier card. To have two physical parts:
determine which battery is connected to which v The embedded storage adapter on the DASD
embedded IOA use the bus number of the IOA with backplane.
symbolic FRU CACHBAT. v The dual battery charger and carrier card. To
determine which battery is connected to which
See symbolic FRU FEATCRD for the location code of embedded IOA use the bus number of the IOA with
the dual battery charger and carrier card if it is not symbolic FRU CACHBAT.
listed in the serviceable event or if you are working the
failing item list here. See symbolic FRU FEATCRD for the location code of
Failing Item: the dual battery charger and carrier card if it is not
listed in the serviceable event or if you are working the
v BACKPLN
failing item list here.
v STORIOA
Failing Item:
v BACKPLN
57C74160 57C74160
v STORIOA
Explanation: I/O adapter detected and recovered a
PCI bus error
57C78008 57C78008
Response: If this event appears in a serviceable event
view, work with the failing item list found there. If this Explanation: A permanent cache battery pack failure
event does not appear in a serviceable event view, no occurred
service action is required. Response: Under a certain configuration, this SRC
If you are working with one of the card types below, may not represent an error that requires a service
the adapter has mulitple physical parts. Choose the action. Depending on the configuration of the system,
card type to identify the physical parts of the storage the Storage IOA may have been altered and/or the
adapter. Storage IOA Cache may have been disabled to allow
attachment of OEM Storage that emulates a Load
Card type 2BE1 (feature RAID enablement card for Source drive. If this is the case, this error will be posted
embedded IOA) read the following: When working the each time the IOA is IPLed and it can be ignored.
FRUs from the serviceable event or the failing item list
here, the embedded storage adapter (STORIOA) has If you are working with one of the card types below,
three physical parts: the adapter has mulitple physical parts. Choose the
card type to identify the physical parts of the storage
v The embedded storage adapter on the I/O
adapter.
backplane.
Card type 57CF (embedded IOAs on DASD backplane v The embedded storage adapter on the I/O
with 2BC2 dual battery charger and carrier card) read backplane.
the following: When working the FRUs from the v The Battery charger and carrier card.
serviceable event or the failing item list here, the
embedded storage adapters (STORIOA) have two See symbolic FRU FEATCRD for the location codes of
physical parts: the FRUs if they are not listed in the serviceable event
v The embedded storage adapter on the DASD or if you are working the failing item list here.
backplane.
Card type 57CF (embedded IOAs on DASD backplane
v The dual battery charger and carrier card. To
with 2BC2 dual battery charger and carrier card for the
determine which battery is connected to which
embedded IOAs) read the following: When working
embedded IOA use the bus number of the IOA with
the FRUs from the serviceable event or the failing item
symbolic FRU CACHBAT.
list here, the embedded storage adapters (STORIOA)
have two physical parts:
See symbolic FRU FEATCRD for the location code of
the dual battery charger and carrier card if it is not v The embedded storage adapter on the DASD
listed in the serviceable event or if you are working the backplane.
failing item list here. v The dual battery charger and carrier card. To
determine which battery is connected to which
Failing Item:
embedded IOA use the bus number of the IOA with
v CACHBAT symbolic FRU CACHBAT.
v STORIOA
v FEATCRD See symbolic FRU FEATCRD for the location code of
the dual battery charger and carrier card if it is not
listed in the serviceable event or if you are working the
57C78009 57C78009 failing item list here.
Explanation: Impending cache battery pack failure Failing Item:
Failing Item: v PTFSRCH
v CACHBAT v STORIOA
v The embedded storage adapter on the I/O v The embedded storage adapter on the I/O
backplane. backplane.
v The RAID enablement card. v The RAID enablement card.
v The Battery charger and carrier card. v The Battery charger and carrier card.
See symbolic FRU FEATCRD for the location codes of See symbolic FRU FEATCRD for the location codes of
the FRUs if they are not listed in the serviceable event the FRUs if they are not listed in the serviceable event
or if you are working the failing item list here. or if you are working the failing item list here.
Card type 57CB (embedded IOA with 2BCF battery Card type 57CB (embedded IOA with 2BCF battery
card for embedded IOA) read the following: When card for embedded IOA) read the following: When
working the FRUs from the serviceable event or the working the FRUs from the serviceable event or the
failing item list here, the embedded storage adapter failing item list here, the embedded storage adapter
(STORIOA) has two physical parts: (STORIOA) has two physical parts:
v The embedded storage adapter on the I/O v The embedded storage adapter on the I/O
backplane. backplane.
v The Battery charger and carrier card. v The Battery charger and carrier card.
See symbolic FRU FEATCRD for the location codes of See symbolic FRU FEATCRD for the location codes of
the FRUs if they are not listed in the serviceable event the FRUs if they are not listed in the serviceable event
or if you are working the failing item list here. or if you are working the failing item list here.
Card type 57CF (embedded IOAs on DASD backplane Card type 57CF (embedded IOAs on DASD backplane
with 2BC2 dual battery charger and carrier card for the with 2BC2 dual battery charger and carrier card for the
embedded IOAs) read the following: When working embedded IOAs) read the following: When working
the FRUs from the serviceable event or the failing item the FRUs from the serviceable event or the failing item
list here, the embedded storage adapters (STORIOA) list here, the embedded storage adapters (STORIOA)
have two physical parts: have two physical parts:
v The embedded storage adapter on the DASD v The embedded storage adapter on the DASD
backplane. backplane.
v The dual battery charger and carrier card. To v The dual battery charger and carrier card. To
determine which battery is connected to which determine which battery is connected to which
embedded IOA use the bus number of the IOA with embedded IOA use the bus number of the IOA with
symbolic FRU CACHBAT. symbolic FRU CACHBAT.
See symbolic FRU FEATCRD for the location code of See symbolic FRU FEATCRD for the location code of
the dual battery charger and carrier card if it is not the dual battery charger and carrier card if it is not
listed in the serviceable event or if you are working the listed in the serviceable event or if you are working the
failing item list here. failing item list here.
Failing Item: Failing Item:
v PTFSRCH v PTFSRCH
v STORIOA v STORIOA
v The embedded storage adapter on the I/O If you are replacing the I/O adapter and you are
backplane. working with one of the card types below, the adapter
v The RAID enablement card. has mulitple physical parts. Choose the card type to
identify the physical parts of the storage adapter.
v The Battery charger and carrier card.
Card type 2BE1 (feature RAID enablement card for
See symbolic FRU FEATCRD for the location codes of embedded IOA) read the following: When working the
the FRUs if they are not listed in the serviceable event FRUs from the serviceable event or the failing item list
or if you are working the failing item list here. here, the embedded storage adapter (STORIOA) has
three physical parts:
Card type 57CB (embedded IOA with 2BCF battery v The embedded storage adapter on the I/O
card for embedded IOA) read the following: When backplane.
working the FRUs from the serviceable event or the v The RAID enablement card.
failing item list here, the embedded storage adapter
(STORIOA) has two physical parts: v The Battery charger and carrier card.
See symbolic FRU FEATCRD for the location codes of Card type 57CB (embedded IOA with 2BCF battery
the FRUs if they are not listed in the serviceable event card for embedded IOA) read the following: When
or if you are working the failing item list here. working the FRUs from the serviceable event or the
failing item list here, the embedded storage adapter
Card type 57CF (embedded IOAs on DASD backplane (STORIOA) has two physical parts:
with 2BC2 dual battery charger and carrier card for the v The embedded storage adapter on the I/O
embedded IOAs) read the following: When working backplane.
the FRUs from the serviceable event or the failing item
list here, the embedded storage adapters (STORIOA) v The Battery charger and carrier card.
have two physical parts:
See symbolic FRU FEATCRD for the location codes of
v The embedded storage adapter on the DASD
the FRUs if they are not listed in the serviceable event
backplane.
or if you are working the failing item list here.
v The dual battery charger and carrier card. To
determine which battery is connected to which Card type 57CF (embedded IOAs on DASD backplane
embedded IOA use the bus number of the IOA with with 2BC2 dual battery charger and carrier card for the
symbolic FRU CACHBAT. embedded IOAs) read the following: When working
the FRUs from the serviceable event or the failing item
See symbolic FRU FEATCRD for the location code of list here, the embedded storage adapters (STORIOA)
the dual battery charger and carrier card if it is not have two physical parts:
listed in the serviceable event or if you are working the
v The embedded storage adapter on the DASD
failing item list here.
backplane.
Failing Item: v The dual battery charger and carrier card. To
v PTFSRCH determine which battery is connected to which
v STORIOA embedded IOA use the bus number of the IOA with
symbolic FRU CACHBAT.
57C78157 57C78157 See symbolic FRU FEATCRD for the location code of
Explanation: I/O adapter card error the dual battery charger and carrier card if it is not
listed in the serviceable event or if you are working the
Response: The FRU list in the Service Action Log will failing item list here.
vary based on the conditions this event was logged for.
Failing Item:
Display the Service Action Log entry for this SRC. If v SVCDOCS
the Failing Item indicates an I/O adapter, then replace
the I/O adapter. If the Failing Item indicates v STORIOA
SVCDOCS, then do NOT replace the I/O adapter. This
is a recoverable error. Use Hardware Service Manager
to re-IPL the virtual I/O processor that is associated
with this I/O adapter. Other resources attached to the
virtual I/O processor may then need to be Varied On.
See symbolic FRU FEATCRD for the location codes of Card type 57CB (embedded IOA with 2BCF battery
the FRUs if they are not listed in the serviceable event card for embedded IOA) read the following: When
or if you are working the failing item list here. working the FRUs from the serviceable event or the
failing item list here, the embedded storage adapter
Card type 57CF (embedded IOAs on DASD backplane (STORIOA) has two physical parts:
with 2BC2 dual battery charger and carrier card for the v The embedded storage adapter on the I/O
embedded IOAs) read the following: When working backplane.
the FRUs from the serviceable event or the failing item v The Battery charger and carrier card.
list here, the embedded storage adapters (STORIOA)
have two physical parts: See symbolic FRU FEATCRD for the location codes of
v The embedded storage adapter on the DASD the FRUs if they are not listed in the serviceable event
backplane. or if you are working the failing item list here.
v The dual battery charger and carrier card. To
determine which battery is connected to which Card type 57CF (embedded IOAs on DASD backplane
embedded IOA use the bus number of the IOA with with 2BC2 dual battery charger and carrier card for the
symbolic FRU CACHBAT. embedded IOAs) read the following: When working
the FRUs from the serviceable event or the failing item
See symbolic FRU FEATCRD for the location code of list here, the embedded storage adapters (STORIOA)
the dual battery charger and carrier card if it is not have two physical parts:
listed in the serviceable event or if you are working the v The embedded storage adapter on the DASD
failing item list here. backplane.
Failing Item: v The dual battery charger and carrier card. To
determine which battery is connected to which
v SVCDOCS
embedded IOA use the bus number of the IOA with
v STORIOA symbolic FRU CACHBAT.
57C79008 57C79008
57C79025 57C79025
Explanation: I/O card does not support functions
expected by devices Explanation: Incompatible device
57C79027 57C79027
57C79020 57C79020
Explanation: Array not functional due to parity out of
Explanation: Two or more disk units missing from synchronization
RAID-5 or RAID-6 array
Response: Array is or would become exposed and
Failing Item: parity data is out of synchronization
v SIP3111
Failing Item:
v SIP3113
57C79021 57C79021
Explanation: Two or more disk units missing from
RAID-5 or RAID-6 array
Failing Item:
v SIP3111
Explanation: Multiple I/O adapters connected in a not Card type 57CF (embedded IOAs on DASD backplane
valid configuration with 2BC2 dual battery charger and carrier card for the
Response: Multiple I/O adapters not capable of embedded IOAs) read the following: When working
similar functions or controlling the same set of devices. the FRUs from the serviceable event or the failing item
list here, the embedded storage adapters (STORIOA)
Failing Item: have two physical parts:
v SIP4041 v The embedded storage adapter on the DASD
backplane.
57C79075 57C79075 v The dual battery charger and carrier card. To
determine which battery is connected to which
Explanation: Incomplete multipath connection embedded IOA use the bus number of the IOA with
between IOA and remote IOA symbolic FRU CACHBAT.
Failing Item:
v SIP4049 See symbolic FRU FEATCRD for the location code of
the dual battery charger and carrier card if it is not
listed in the serviceable event or if you are working the
57C79076 57C79076 failing item list here.
Explanation: Missing auxiliary IOA or remote IOA Failing Item:
Failing Item: v FI01105
v SIP4047 v STORIOA
Response: If you are working with one of the card Response: If you are working with one of the card
types below, the adapter has mulitple physical parts. types below, the adapter has mulitple physical parts.
Choose the card type to identify the physical parts of Choose the card type to identify the physical parts of
the storage adapter. the storage adapter.
Card type 2BE1 (feature RAID enablement card for Card type 2BE1 (feature RAID enablement card for
embedded IOA) read the following: When working the embedded IOA) read the following: When working the
FRUs from the serviceable event or the failing item list FRUs from the serviceable event or the failing item list
here, the embedded storage adapter (STORIOA) has here, the embedded storage adapter (STORIOA) has
three physical parts: three physical parts:
57C7FF3D 57C7FF3D
Explanation: I/O adapter detected a recoverable error
Response: If you are working with one of the card
types below, the adapter has mulitple physical parts.
Choose the card type to identify the physical parts of
the storage adapter.
Card type 2BE1 (feature RAID enablement card for
embedded IOA) read the following: When working the
FRUs from the serviceable event or the failing item list
here, the embedded storage adapter (STORIOA) has
three physical parts:
v The embedded storage adapter on the I/O
backplane.
v The RAID enablement card.
v The Battery charger and carrier card.
Failing Item:
57CD3000 57CD3000
v DISKPWR
v DEVBPLN Explanation: A permanent failure occurred
v SASEXP Response: If you are working with one of the card
types below, the adapter has mulitple physical parts.
Choose the card type to identify the physical parts of
57CD1515 57CD1515
the storage adapter.
Explanation: A fatal error occurred on power supply 1
Card type 2BE1 (feature RAID enablement card for
Problem determination: This SRC can be the result of embedded IOA) read the following: When working the
a loss of utility power, battery back up or UPS power FRUs from the serviceable event or the failing item list
to the I/O storage unit. The unit and power supply here, the embedded storage adapter (STORIOA) has
that detected the problem are in the FRU list of the three physical parts:
serviceable event. Before starting a repair action for this v The embedded storage adapter on the I/O
problem verify that utility power, BBU or UPS to the backplane.
unit was not interrupted at the time the SRC was
v The RAID enablement card.
logged. If there was an interruption to power at about
the same time then no service is required and this v The Battery charger and carrier card.
problem can be closed.
See symbolic FRU FEATCRD for the location codes of
Failing Item: the FRUs if they are not listed in the serviceable event
v DISKPWR or if you are working the failing item list here.
v DEVBPLN
Card type 57CB (embedded IOA with 2BCF battery
v SASEXP
card for embedded IOA) read the following: When
working the FRUs from the serviceable event or the
57CD1521 57CD1521 failing item list here, the embedded storage adapter
(STORIOA) has two physical parts:
Explanation: A non-fatal error occurred on power
supply 2 v The embedded storage adapter on the I/O
backplane.
Failing Item:
v The Battery charger and carrier card.
v DISKPWR
v DEVBPLN See symbolic FRU FEATCRD for the location codes of
v SASEXP the FRUs if they are not listed in the serviceable event
or if you are working the failing item list here.
v BACKPLN
57CD4150 57CD4150
v STORIOA
Explanation: I/O adapter detected PCI bus error
Response: If this event appears in a serviceable event 57CD4160 57CD4160
view, work with the failing item list found there. If this
event does not appear in a serviceable event view, no Explanation: I/O adapter detected and recovered a
service action is required. PCI bus error
If you are working with one of the card types below, Response: If this event appears in a serviceable event
the adapter has mulitple physical parts. Choose the view, work with the failing item list found there. If this
card type to identify the physical parts of the storage event does not appear in a serviceable event view, no
adapter. service action is required.
Card type 2BE1 (feature RAID enablement card for If you are working with one of the card types below,
embedded IOA) read the following: When working the the adapter has mulitple physical parts. Choose the
FRUs from the serviceable event or the failing item list card type to identify the physical parts of the storage
here, the embedded storage adapter (STORIOA) has adapter.
three physical parts: Card type 2BE1 (feature RAID enablement card for
v The embedded storage adapter on the I/O embedded IOA) read the following: When working the
backplane. FRUs from the serviceable event or the failing item list
v The RAID enablement card. here, the embedded storage adapter (STORIOA) has
three physical parts:
v The Battery charger and carrier card.
v The embedded storage adapter on the I/O
See symbolic FRU FEATCRD for the location codes of backplane.
the FRUs if they are not listed in the serviceable event v The RAID enablement card.
or if you are working the failing item list here. v The Battery charger and carrier card.
Card type 57CB (embedded IOA with 2BCF battery See symbolic FRU FEATCRD for the location codes of
card for embedded IOA) read the following: When the FRUs if they are not listed in the serviceable event
working the FRUs from the serviceable event or the or if you are working the failing item list here.
failing item list here, the embedded storage adapter
(STORIOA) has two physical parts: Card type 57CB (embedded IOA with 2BCF battery
v The embedded storage adapter on the I/O card for embedded IOA) read the following: When
backplane. working the FRUs from the serviceable event or the
v The Battery charger and carrier card. failing item list here, the embedded storage adapter
(STORIOA) has two physical parts:
See symbolic FRU FEATCRD for the location codes of v The embedded storage adapter on the I/O
the FRUs if they are not listed in the serviceable event backplane.
or if you are working the failing item list here. v The Battery charger and carrier card.
Card type 57CF (embedded IOAs on DASD backplane See symbolic FRU FEATCRD for the location codes of
with 2BC2 dual battery charger and carrier card for the the FRUs if they are not listed in the serviceable event
embedded IOAs) read the following: When working or if you are working the failing item list here.
the FRUs from the serviceable event or the failing item
list here, the embedded storage adapters (STORIOA) Card type 57CF (embedded IOAs on DASD backplane
have two physical parts: with 2BC2 dual battery charger and carrier card for the
v The embedded storage adapter on the DASD embedded IOAs) read the following: When working
backplane. the FRUs from the serviceable event or the failing item
v The dual battery charger and carrier card. To list here, the embedded storage adapters (STORIOA)
determine which battery is connected to which have two physical parts:
embedded IOA use the bus number of the IOA with v The embedded storage adapter on the DASD
symbolic FRU CACHBAT. backplane.
v The dual battery charger and carrier card. To
See symbolic FRU FEATCRD for the location code of determine which battery is connected to which
the dual battery charger and carrier card if it is not embedded IOA use the bus number of the IOA with
listed in the serviceable event or if you are working the symbolic FRU CACHBAT.
failing item list here.
Failing Item:
Failing Item: embedded IOA) read the following: When working the
v PTFSRCH FRUs from the serviceable event or the failing item list
here, the embedded storage adapter (STORIOA) has
v STORIOA
three physical parts:
v The embedded storage adapter on the I/O
57CD8130 57CD8130 backplane.
Explanation: IOA detected recoverable device bus v The RAID enablement card.
error v The Battery charger and carrier card.
Response: If this event appears in a serviceable event
view, work with the failing item list found there. If this See symbolic FRU FEATCRD for the location codes of
event does not appear in a serviceable event view, no the FRUs if they are not listed in the serviceable event
service action is required. or if you are working the failing item list here.
Failing Item: Card type 57CB (embedded IOA with 2BCF battery
v SIP3150 card for embedded IOA) read the following: When
working the FRUs from the serviceable event or the
failing item list here, the embedded storage adapter
57CD8140 57CD8140
(STORIOA) has two physical parts:
Explanation: IOA detected recoverable device bus v The embedded storage adapter on the I/O
error backplane.
Response: If this event appears in a serviceable event v The Battery charger and carrier card.
view, work with the failing item list found there. If this
event does not appear in a serviceable event view, no See symbolic FRU FEATCRD for the location codes of
service action is required. the FRUs if they are not listed in the serviceable event
or if you are working the failing item list here.
Failing Item:
v SIP3150 Card type 57CF (embedded IOAs on DASD backplane
with 2BC2 dual battery charger and carrier card for the
57CD8141 57CD8141 embedded IOAs) read the following: When working
the FRUs from the serviceable event or the failing item
Explanation: IOA detected recoverable device error list here, the embedded storage adapters (STORIOA)
Response: No action is required. This reference code have two physical parts:
is logged for information only. v The embedded storage adapter on the DASD
backplane.
FRUs from the serviceable event or the failing item list here, the embedded storage adapter (STORIOA) has
here, the embedded storage adapter (STORIOA) has three physical parts:
three physical parts: v The embedded storage adapter on the I/O
v The embedded storage adapter on the I/O backplane.
backplane. v The RAID enablement card.
v The RAID enablement card. v The Battery charger and carrier card.
v The Battery charger and carrier card.
See symbolic FRU FEATCRD for the location codes of
See symbolic FRU FEATCRD for the location codes of the FRUs if they are not listed in the serviceable event
the FRUs if they are not listed in the serviceable event or if you are working the failing item list here.
or if you are working the failing item list here.
Card type 57CB (embedded IOA with 2BCF battery
Card type 57CB (embedded IOA with 2BCF battery card for embedded IOA) read the following: When
card for embedded IOA) read the following: When working the FRUs from the serviceable event or the
working the FRUs from the serviceable event or the failing item list here, the embedded storage adapter
failing item list here, the embedded storage adapter (STORIOA) has two physical parts:
(STORIOA) has two physical parts: v The embedded storage adapter on the I/O
v The embedded storage adapter on the I/O backplane.
backplane. v The Battery charger and carrier card.
v The Battery charger and carrier card.
See symbolic FRU FEATCRD for the location codes of
See symbolic FRU FEATCRD for the location codes of the FRUs if they are not listed in the serviceable event
the FRUs if they are not listed in the serviceable event or if you are working the failing item list here.
or if you are working the failing item list here.
Card type 57CF (embedded IOAs on DASD backplane
Card type 57CF (embedded IOAs on DASD backplane with 2BC2 dual battery charger and carrier card for the
with 2BC2 dual battery charger and carrier card for the embedded IOAs) read the following: When working
embedded IOAs) read the following: When working the FRUs from the serviceable event or the failing item
the FRUs from the serviceable event or the failing item list here, the embedded storage adapters (STORIOA)
list here, the embedded storage adapters (STORIOA) have two physical parts:
have two physical parts: v The embedded storage adapter on the DASD
v The embedded storage adapter on the DASD backplane.
backplane. v The dual battery charger and carrier card. To
v The dual battery charger and carrier card. To determine which battery is connected to which
determine which battery is connected to which embedded IOA use the bus number of the IOA with
embedded IOA use the bus number of the IOA with symbolic FRU CACHBAT.
symbolic FRU CACHBAT.
See symbolic FRU FEATCRD for the location code of
See symbolic FRU FEATCRD for the location code of the dual battery charger and carrier card if it is not
the dual battery charger and carrier card if it is not listed in the serviceable event or if you are working the
listed in the serviceable event or if you are working the failing item list here.
failing item list here.
Failing Item:
Failing Item: v PTFSRCH
v PTFSRCH v STORIOA
v STORIOA
57CD8156 57CD8156
57CD8155 57CD8155
Explanation: A permanent failure occurred
Explanation: A permanent failure occurred
Response: If you are working with one of the card
Response: If you are working with one of the card types below, the adapter has mulitple physical parts.
types below, the adapter has mulitple physical parts. Choose the card type to identify the physical parts of
Choose the card type to identify the physical parts of the storage adapter.
the storage adapter.
Card type 2BE1 (feature RAID enablement card for
Card type 2BE1 (feature RAID enablement card for embedded IOA) read the following: When working the
embedded IOA) read the following: When working the FRUs from the serviceable event or the failing item list
FRUs from the serviceable event or the failing item list
here, the embedded storage adapter (STORIOA) has with this I/O adapter. Other resources attached to the
three physical parts: virtual I/O processor may then need to be Varied On.
v The embedded storage adapter on the I/O If you are replacing the I/O adapter and you are
backplane. working with one of the card types below, the adapter
v The RAID enablement card. has mulitple physical parts. Choose the card type to
v The Battery charger and carrier card. identify the physical parts of the storage adapter.
Card type 2BE1 (feature RAID enablement card for
See symbolic FRU FEATCRD for the location codes of embedded IOA) read the following: When working the
the FRUs if they are not listed in the serviceable event FRUs from the serviceable event or the failing item list
or if you are working the failing item list here. here, the embedded storage adapter (STORIOA) has
three physical parts:
Card type 57CB (embedded IOA with 2BCF battery v The embedded storage adapter on the I/O
card for embedded IOA) read the following: When backplane.
working the FRUs from the serviceable event or the
failing item list here, the embedded storage adapter v The RAID enablement card.
(STORIOA) has two physical parts: v The Battery charger and carrier card.
v The embedded storage adapter on the I/O
backplane. See symbolic FRU FEATCRD for the location codes of
the FRUs if they are not listed in the serviceable event
v The Battery charger and carrier card.
or if you are working the failing item list here.
57CD8157 57CD8157
See symbolic FRU FEATCRD for the location code of
Explanation: I/O adapter card error the dual battery charger and carrier card if it is not
listed in the serviceable event or if you are working the
Response: The FRU list in the Service Action Log will failing item list here.
vary based on the conditions this event was logged for.
Failing Item:
Display the Service Action Log entry for this SRC. If
the Failing Item indicates an I/O adapter, then replace v SVCDOCS
the I/O adapter. If the Failing Item indicates v STORIOA
SVCDOCS, then do NOT replace the I/O adapter. This
is a recoverable error. Use Hardware Service Manager
to re-IPL the virtual I/O processor that is associated
See symbolic FRU FEATCRD for the location codes of Card type 57CB (embedded IOA with 2BCF battery
the FRUs if they are not listed in the serviceable event card for embedded IOA) read the following: When
or if you are working the failing item list here. working the FRUs from the serviceable event or the
failing item list here, the embedded storage adapter
Card type 57CF (embedded IOAs on DASD backplane (STORIOA) has two physical parts:
with 2BC2 dual battery charger and carrier card for the v The embedded storage adapter on the I/O
embedded IOAs) read the following: When working backplane.
the FRUs from the serviceable event or the failing item v The Battery charger and carrier card.
list here, the embedded storage adapters (STORIOA)
have two physical parts: See symbolic FRU FEATCRD for the location codes of
v The embedded storage adapter on the DASD the FRUs if they are not listed in the serviceable event
backplane. or if you are working the failing item list here.
v The dual battery charger and carrier card. To
determine which battery is connected to which Card type 57CF (embedded IOAs on DASD backplane
embedded IOA use the bus number of the IOA with with 2BC2 dual battery charger and carrier card for the
symbolic FRU CACHBAT. embedded IOAs) read the following: When working
the FRUs from the serviceable event or the failing item
See symbolic FRU FEATCRD for the location code of list here, the embedded storage adapters (STORIOA)
the dual battery charger and carrier card if it is not have two physical parts:
listed in the serviceable event or if you are working the v The embedded storage adapter on the DASD
failing item list here. backplane.
Failing Item: v The dual battery charger and carrier card. To
determine which battery is connected to which
v SVCDOCS
embedded IOA use the bus number of the IOA with
v STORIOA symbolic FRU CACHBAT.
57CD9008 57CD9008
57CD9025 57CD9025
Explanation: I/O card does not support functions
expected by devices Explanation: Incompatible device
57CD9027 57CD9027
57CD9020 57CD9020
Explanation: Array not functional due to parity out of
Explanation: Two or more disk units missing from synchronization
RAID-5 or RAID-6 array
Response: Array is or would become exposed and
Failing Item: parity data is out of synchronization
v SIP3111
Failing Item:
v SIP3113
57CD9021 57CD9021
Explanation: Two or more disk units missing from
RAID-5 or RAID-6 array
Failing Item:
v SIP3111
Explanation: Multiple I/O adapters connected in a not Card type 57CF (embedded IOAs on DASD backplane
valid configuration with 2BC2 dual battery charger and carrier card for the
Response: Multiple I/O adapters not capable of embedded IOAs) read the following: When working
similar functions or controlling the same set of devices. the FRUs from the serviceable event or the failing item
list here, the embedded storage adapters (STORIOA)
Failing Item: have two physical parts:
v SIP3141 v The embedded storage adapter on the DASD
backplane.
57CD9075 57CD9075 v The dual battery charger and carrier card. To
determine which battery is connected to which
Explanation: Incomplete multipath connection embedded IOA use the bus number of the IOA with
between IOA and remote IOA symbolic FRU CACHBAT.
Failing Item:
v SIP3149 See symbolic FRU FEATCRD for the location code of
the dual battery charger and carrier card if it is not
listed in the serviceable event or if you are working the
57CD9076 57CD9076 failing item list here.
Explanation: Missing auxiliary IOA or remote IOA Failing Item:
Failing Item: v FI01105
v SIP3147 v STORIOA
Response: If you are working with one of the card Response: If you are working with one of the card
types below, the adapter has mulitple physical parts. types below, the adapter has mulitple physical parts.
Choose the card type to identify the physical parts of Choose the card type to identify the physical parts of
the storage adapter. the storage adapter.
Card type 2BE1 (feature RAID enablement card for Card type 2BE1 (feature RAID enablement card for
embedded IOA) read the following: When working the embedded IOA) read the following: When working the
FRUs from the serviceable event or the failing item list FRUs from the serviceable event or the failing item list
here, the embedded storage adapter (STORIOA) has here, the embedded storage adapter (STORIOA) has
three physical parts: three physical parts:
Explanation: I/O adapter detected a recoverable error Explanation: Device backplane problem
Response: If you are working with one of the card Failing Item:
types below, the adapter has mulitple physical parts. v SASEXP
Choose the card type to identify the physical parts of v SASCABL
the storage adapter.
v STORIOA
Card type 2BE1 (feature RAID enablement card for v DEVBPLN
embedded IOA) read the following: When working the
FRUs from the serviceable event or the failing item list
here, the embedded storage adapter (STORIOA) has
three physical parts:
v The embedded storage adapter on the I/O
backplane.
v The RAID enablement card.
v The Battery charger and carrier card.
v The embedded storage adapter on the I/O contact your service provider.
backplane.
Failing Item:
v The Battery charger and carrier card.
v PTFSRCH
See symbolic FRU FEATCRD for the location codes of
the FRUs if they are not listed in the serviceable event 57CF34FF 57CF34FF
or if you are working the failing item list here.
Explanation: Format in progress
Card type 57CF (embedded IOAs on DASD backplane Response: No action required. This reference code is
with 2BC2 dual battery charger and carrier card). When logged for information only.
working the FRUs from the serviceable event or the
failing item list here, the embedded storage adapters
57CF3601 57CF3601
(STORIOA) have two physical parts:
v The embedded storage adapter on the DASD Explanation: System log entry only. No service action
backplane. required.
v The dual battery charger and carrier card. To
determine which battery is connected to which 57CF4010 57CF4010
embedded IOA use the bus number of the IOA with
symbolic FRU CACHBAT. Explanation: Configuration error
Response: Incorrect connection between cascaded
See symbolic FRU FEATCRD for the location code of enclosures.
the dual battery charger and carrier card if it is not
listed in the serviceable event or if you are working the Failing Item:
failing item list here. v SIP3142
Failing Item:
v SIP4050 57CF4020 57CF4020
v SIP4053 v DEVBPLN
v SASCABL v STORIOA
v SASEXP v FI01105
Explanation: Multipath redundancy level increased Explanation: Temporary device bus fabric error
Explanation: System log entry only. No service action Explanation: Unsupported enclosure function detected
required.
Failing Item:
v SIP3145
57CF4100 57CF4100
Explanation: Device bus fabric error 57CF4150 57CF4150
Response: If you are working with one of the card Explanation: I/O adapter detected PCI bus error
types below, the adapter has mulitple physical parts.
Choose the card type to identify the physical parts of Response: If this event appears in a serviceable event
the storage adapter. view, work with the failing item list found there. If this
event does not appear in a serviceable event view, no
Card type 57CB (embedded IOA with 2BCF battery service action is required.
card for embedded IOA) read the following: When
working the FRUs from the serviceable event or the If you are working with one of the card types below,
failing item list here, the embedded storage adapter the adapter has mulitple physical parts. Choose the
(STORIOA) has two physical parts: card type to identify the physical parts of the storage
adapter.
v The embedded storage adapter on the I/O
backplane. Card type 2BE1 (feature RAID enablement card for
v The Battery charger and carrier card. embedded IOA) read the following: When working the
FRUs from the serviceable event or the failing item list
See symbolic FRU FEATCRD for the location codes of here, the embedded storage adapter (STORIOA) has
the FRUs if they are not listed in the serviceable event three physical parts:
or if you are working the failing item list here. v The embedded storage adapter on the I/O
backplane.
Card type 57CF (embedded IOAs on DASD backplane v The RAID enablement card.
with 2BC2 dual battery charger and carrier card for the v The Battery charger and carrier card.
embedded IOAs) read the following: When working
the FRUs from the serviceable event or the failing item
list here, the embedded storage adapters (STORIOA)
have two physical parts:
See symbolic FRU FEATCRD for the location codes of v The RAID enablement card.
the FRUs if they are not listed in the serviceable event v The Battery charger and carrier card.
or if you are working the failing item list here.
See symbolic FRU FEATCRD for the location codes of
Card type 57CB (embedded IOA with 2BCF battery the FRUs if they are not listed in the serviceable event
card for embedded IOA) read the following: When or if you are working the failing item list here.
working the FRUs from the serviceable event or the
failing item list here, the embedded storage adapter Card type 57CB (embedded IOA with 2BCF battery
(STORIOA) has two physical parts: card for embedded IOA) read the following: When
v The embedded storage adapter on the I/O working the FRUs from the serviceable event or the
backplane. failing item list here, the embedded storage adapter
v The Battery charger and carrier card. (STORIOA) has two physical parts:
v The embedded storage adapter on the I/O
See symbolic FRU FEATCRD for the location codes of backplane.
the FRUs if they are not listed in the serviceable event v The Battery charger and carrier card.
or if you are working the failing item list here.
See symbolic FRU FEATCRD for the location codes of
Card type 57CF (embedded IOAs on DASD backplane the FRUs if they are not listed in the serviceable event
with 2BC2 dual battery charger and carrier card for the or if you are working the failing item list here.
embedded IOAs) read the following: When working
the FRUs from the serviceable event or the failing item Card type 57CF (embedded IOAs on DASD backplane
list here, the embedded storage adapters (STORIOA) with 2BC2 dual battery charger and carrier card for the
have two physical parts: embedded IOAs) read the following: When working
v The embedded storage adapter on the DASD the FRUs from the serviceable event or the failing item
backplane. list here, the embedded storage adapters (STORIOA)
v The dual battery charger and carrier card. To have two physical parts:
determine which battery is connected to which v The embedded storage adapter on the DASD
embedded IOA use the bus number of the IOA with backplane.
symbolic FRU CACHBAT. v The dual battery charger and carrier card. To
determine which battery is connected to which
See symbolic FRU FEATCRD for the location code of embedded IOA use the bus number of the IOA with
the dual battery charger and carrier card if it is not symbolic FRU CACHBAT.
listed in the serviceable event or if you are working the
failing item list here. See symbolic FRU FEATCRD for the location code of
Failing Item: the dual battery charger and carrier card if it is not
listed in the serviceable event or if you are working the
v BACKPLN
failing item list here.
v STORIOA
Failing Item:
v BACKPLN
57CF4160 57CF4160
v STORIOA
Explanation: I/O adapter detected and recovered a
PCI bus error
57CF8008 57CF8008
Response: If this event appears in a serviceable event
view, work with the failing item list found there. If this Explanation: A permanent cache battery pack failure
event does not appear in a serviceable event view, no occurred
service action is required. Response: Under a certain configuration, this SRC
If you are working with one of the card types below, may not represent an error that requires a service
the adapter has mulitple physical parts. Choose the action. Depending on the configuration of the system,
card type to identify the physical parts of the storage the Storage IOA may have been altered and/or the
adapter. Storage IOA Cache may have been disabled to allow
attachment of OEM Storage that emulates a Load
Card type 2BE1 (feature RAID enablement card for Source drive. If this is the case, this error will be posted
embedded IOA) read the following: When working the each time the IOA is IPLed and it can be ignored.
FRUs from the serviceable event or the failing item list
here, the embedded storage adapter (STORIOA) has If you are working with one of the card types below,
three physical parts: the adapter has mulitple physical parts. Choose the
card type to identify the physical parts of the storage
v The embedded storage adapter on the I/O
adapter.
backplane.
Card type 57CF (embedded IOAs on DASD backplane v The embedded storage adapter on the I/O
with 2BC2 dual battery charger and carrier card) read backplane.
the following: When working the FRUs from the v The Battery charger and carrier card.
serviceable event or the failing item list here, the
embedded storage adapters (STORIOA) have two See symbolic FRU FEATCRD for the location codes of
physical parts: the FRUs if they are not listed in the serviceable event
v The embedded storage adapter on the DASD or if you are working the failing item list here.
backplane.
Card type 57CF (embedded IOAs on DASD backplane
v The dual battery charger and carrier card. To
with 2BC2 dual battery charger and carrier card for the
determine which battery is connected to which
embedded IOAs) read the following: When working
embedded IOA use the bus number of the IOA with
the FRUs from the serviceable event or the failing item
symbolic FRU CACHBAT.
list here, the embedded storage adapters (STORIOA)
have two physical parts:
See symbolic FRU FEATCRD for the location code of
the dual battery charger and carrier card if it is not v The embedded storage adapter on the DASD
listed in the serviceable event or if you are working the backplane.
failing item list here. v The dual battery charger and carrier card. To
determine which battery is connected to which
Failing Item:
embedded IOA use the bus number of the IOA with
v CACHBAT symbolic FRU CACHBAT.
v STORIOA
v FEATCRD See symbolic FRU FEATCRD for the location code of
the dual battery charger and carrier card if it is not
listed in the serviceable event or if you are working the
57CF8009 57CF8009 failing item list here.
Explanation: Impending cache battery pack failure Failing Item:
Failing Item: v PTFSRCH
v CACHBAT v STORIOA
v The embedded storage adapter on the I/O v The embedded storage adapter on the I/O
backplane. backplane.
v The RAID enablement card. v The RAID enablement card.
v The Battery charger and carrier card. v The Battery charger and carrier card.
See symbolic FRU FEATCRD for the location codes of See symbolic FRU FEATCRD for the location codes of
the FRUs if they are not listed in the serviceable event the FRUs if they are not listed in the serviceable event
or if you are working the failing item list here. or if you are working the failing item list here.
Card type 57CB (embedded IOA with 2BCF battery Card type 57CB (embedded IOA with 2BCF battery
card for embedded IOA) read the following: When card for embedded IOA) read the following: When
working the FRUs from the serviceable event or the working the FRUs from the serviceable event or the
failing item list here, the embedded storage adapter failing item list here, the embedded storage adapter
(STORIOA) has two physical parts: (STORIOA) has two physical parts:
v The embedded storage adapter on the I/O v The embedded storage adapter on the I/O
backplane. backplane.
v The Battery charger and carrier card. v The Battery charger and carrier card.
See symbolic FRU FEATCRD for the location codes of See symbolic FRU FEATCRD for the location codes of
the FRUs if they are not listed in the serviceable event the FRUs if they are not listed in the serviceable event
or if you are working the failing item list here. or if you are working the failing item list here.
Card type 57CF (embedded IOAs on DASD backplane Card type 57CF (embedded IOAs on DASD backplane
with 2BC2 dual battery charger and carrier card for the with 2BC2 dual battery charger and carrier card for the
embedded IOAs) read the following: When working embedded IOAs) read the following: When working
the FRUs from the serviceable event or the failing item the FRUs from the serviceable event or the failing item
list here, the embedded storage adapters (STORIOA) list here, the embedded storage adapters (STORIOA)
have two physical parts: have two physical parts:
v The embedded storage adapter on the DASD v The embedded storage adapter on the DASD
backplane. backplane.
v The dual battery charger and carrier card. To v The dual battery charger and carrier card. To
determine which battery is connected to which determine which battery is connected to which
embedded IOA use the bus number of the IOA with embedded IOA use the bus number of the IOA with
symbolic FRU CACHBAT. symbolic FRU CACHBAT.
See symbolic FRU FEATCRD for the location code of See symbolic FRU FEATCRD for the location code of
the dual battery charger and carrier card if it is not the dual battery charger and carrier card if it is not
listed in the serviceable event or if you are working the listed in the serviceable event or if you are working the
failing item list here. failing item list here.
Failing Item: Failing Item:
v PTFSRCH v PTFSRCH
v STORIOA v STORIOA
v The embedded storage adapter on the I/O If you are replacing the I/O adapter and you are
backplane. working with one of the card types below, the adapter
v The RAID enablement card. has mulitple physical parts. Choose the card type to
identify the physical parts of the storage adapter.
v The Battery charger and carrier card.
Card type 2BE1 (feature RAID enablement card for
See symbolic FRU FEATCRD for the location codes of embedded IOA) read the following: When working the
the FRUs if they are not listed in the serviceable event FRUs from the serviceable event or the failing item list
or if you are working the failing item list here. here, the embedded storage adapter (STORIOA) has
three physical parts:
Card type 57CB (embedded IOA with 2BCF battery v The embedded storage adapter on the I/O
card for embedded IOA) read the following: When backplane.
working the FRUs from the serviceable event or the v The RAID enablement card.
failing item list here, the embedded storage adapter
(STORIOA) has two physical parts: v The Battery charger and carrier card.
See symbolic FRU FEATCRD for the location codes of Card type 57CB (embedded IOA with 2BCF battery
the FRUs if they are not listed in the serviceable event card for embedded IOA) read the following: When
or if you are working the failing item list here. working the FRUs from the serviceable event or the
failing item list here, the embedded storage adapter
Card type 57CF (embedded IOAs on DASD backplane (STORIOA) has two physical parts:
with 2BC2 dual battery charger and carrier card for the v The embedded storage adapter on the I/O
embedded IOAs) read the following: When working backplane.
the FRUs from the serviceable event or the failing item
list here, the embedded storage adapters (STORIOA) v The Battery charger and carrier card.
have two physical parts:
See symbolic FRU FEATCRD for the location codes of
v The embedded storage adapter on the DASD
the FRUs if they are not listed in the serviceable event
backplane.
or if you are working the failing item list here.
v The dual battery charger and carrier card. To
determine which battery is connected to which Card type 57CF (embedded IOAs on DASD backplane
embedded IOA use the bus number of the IOA with with 2BC2 dual battery charger and carrier card for the
symbolic FRU CACHBAT. embedded IOAs) read the following: When working
the FRUs from the serviceable event or the failing item
See symbolic FRU FEATCRD for the location code of list here, the embedded storage adapters (STORIOA)
the dual battery charger and carrier card if it is not have two physical parts:
listed in the serviceable event or if you are working the
v The embedded storage adapter on the DASD
failing item list here.
backplane.
Failing Item: v The dual battery charger and carrier card. To
v PTFSRCH determine which battery is connected to which
v STORIOA embedded IOA use the bus number of the IOA with
symbolic FRU CACHBAT.
57CF8157 57CF8157 See symbolic FRU FEATCRD for the location code of
Explanation: I/O adapter card error the dual battery charger and carrier card if it is not
listed in the serviceable event or if you are working the
Response: The FRU list in the Service Action Log will failing item list here.
vary based on the conditions this event was logged for.
Failing Item:
Display the Service Action Log entry for this SRC. If v SVCDOCS
the Failing Item indicates an I/O adapter, then replace
the I/O adapter. If the Failing Item indicates v STORIOA
SVCDOCS, then do NOT replace the I/O adapter. This
is a recoverable error. Use Hardware Service Manager
to re-IPL the virtual I/O processor that is associated
with this I/O adapter. Other resources attached to the
virtual I/O processor may then need to be Varied On.
See symbolic FRU FEATCRD for the location codes of Card type 57CB (embedded IOA with 2BCF battery
the FRUs if they are not listed in the serviceable event card for embedded IOA) read the following: When
or if you are working the failing item list here. working the FRUs from the serviceable event or the
failing item list here, the embedded storage adapter
Card type 57CF (embedded IOAs on DASD backplane (STORIOA) has two physical parts:
with 2BC2 dual battery charger and carrier card for the v The embedded storage adapter on the I/O
embedded IOAs) read the following: When working backplane.
the FRUs from the serviceable event or the failing item v The Battery charger and carrier card.
list here, the embedded storage adapters (STORIOA)
have two physical parts: See symbolic FRU FEATCRD for the location codes of
v The embedded storage adapter on the DASD the FRUs if they are not listed in the serviceable event
backplane. or if you are working the failing item list here.
v The dual battery charger and carrier card. To
determine which battery is connected to which Card type 57CF (embedded IOAs on DASD backplane
embedded IOA use the bus number of the IOA with with 2BC2 dual battery charger and carrier card for the
symbolic FRU CACHBAT. embedded IOAs) read the following: When working
the FRUs from the serviceable event or the failing item
See symbolic FRU FEATCRD for the location code of list here, the embedded storage adapters (STORIOA)
the dual battery charger and carrier card if it is not have two physical parts:
listed in the serviceable event or if you are working the v The embedded storage adapter on the DASD
failing item list here. backplane.
Failing Item: v The dual battery charger and carrier card. To
determine which battery is connected to which
v SVCDOCS
embedded IOA use the bus number of the IOA with
v STORIOA symbolic FRU CACHBAT.
57CF9008 57CF9008
57CF9025 57CF9025
Explanation: I/O card does not support functions
expected by devices Explanation: Incompatible device
57CF9027 57CF9027
57CF9020 57CF9020
Explanation: Array not functional due to parity out of
Explanation: Two or more disk units missing from synchronization
RAID-5 or RAID-6 array
Response: Array is or would become exposed and
Failing Item: parity data is out of synchronization
v SIP3111
Failing Item:
v SIP3113
57CF9021 57CF9021
Explanation: Two or more disk units missing from
RAID-5 or RAID-6 array
Failing Item:
v SIP3111
Explanation: Multiple I/O adapters connected in a not Card type 57CF (embedded IOAs on DASD backplane
valid configuration with 2BC2 dual battery charger and carrier card for the
Response: Multiple I/O adapters not capable of embedded IOAs) read the following: When working
similar functions or controlling the same set of devices. the FRUs from the serviceable event or the failing item
list here, the embedded storage adapters (STORIOA)
Failing Item: have two physical parts:
v SIP4041 v The embedded storage adapter on the DASD
backplane.
57CF9075 57CF9075 v The dual battery charger and carrier card. To
determine which battery is connected to which
Explanation: Incomplete multipath connection embedded IOA use the bus number of the IOA with
between IOA and remote IOA symbolic FRU CACHBAT.
Failing Item:
v SIP4049 See symbolic FRU FEATCRD for the location code of
the dual battery charger and carrier card if it is not
listed in the serviceable event or if you are working the
57CF9076 57CF9076 failing item list here.
Explanation: Missing auxiliary IOA or remote IOA Failing Item:
Failing Item: v FI01105
v SIP4047 v STORIOA
Response: If you are working with one of the card Response: If you are working with one of the card
types below, the adapter has mulitple physical parts. types below, the adapter has mulitple physical parts.
Choose the card type to identify the physical parts of Choose the card type to identify the physical parts of
the storage adapter. the storage adapter.
Card type 2BE1 (feature RAID enablement card for Card type 2BE1 (feature RAID enablement card for
embedded IOA) read the following: When working the embedded IOA) read the following: When working the
FRUs from the serviceable event or the failing item list FRUs from the serviceable event or the failing item list
here, the embedded storage adapter (STORIOA) has here, the embedded storage adapter (STORIOA) has
three physical parts: three physical parts:
57CFFF3D 57CFFF3D
Explanation: I/O adapter detected a recoverable error
Response: If you are working with one of the card
types below, the adapter has mulitple physical parts.
Choose the card type to identify the physical parts of
the storage adapter.
Card type 2BE1 (feature RAID enablement card for
embedded IOA) read the following: When working the
FRUs from the serviceable event or the failing item list
here, the embedded storage adapter (STORIOA) has
three physical parts:
v The embedded storage adapter on the I/O
backplane.
v The RAID enablement card.
v The Battery charger and carrier card.
Explanation: A port failure was detected on port 0 v Check the Product Activity Log for other entries that
indicate interface problems and work those
Failing Item: problems.
v FCPORT v Check the device firmware level and apply the latest
v FCIOA PTFs.
v FCDEV v Check for LIC logs with major code 2E00. Contact
your next level of support with the information you
v OPT_CLN
have gathered.
Problem determination: IPL the IOP to retry the
57FC3121 57FC3121
device identification process. If the error persists then
Explanation: A port failure was detected on port 1 contact your service provider.
Failing Item: Failing Item:
v PTFSRCH
57FC8300 57FC8300
Explanation: IOA hardware error or PCI bus error
57FC34FF 57FC34FF
Failing Item:
Explanation: Format in progress
v FCIOA
Response: The device indicated that a format is in
v ANYBRDG
progress. When the format is complete, the device
should be usable. No action is required. This reference v PTFSRCH
code is logged for information only. v OPT_CLN
57FC8131 57FC8131
57FC9903 57FC9903
Explanation: Recovered Fibre Channel interface error
on port 1 Explanation: Tape device information was logged.
Informational event, no service required.
Response: No action required. This reference code is
logged for information only.
57FCB000 57FCB000
57FCC000 57FCC000
Explanation: System log entry only, no service action
required
Response: No action is required. This reference code
is logged for information only.
57FCC402 57FCC402
Explanation: Licensed Internal Code error
Failing Item:
v PTFSRCH
v STORIOA
57FF3140 57FF3140
v FI01140
Explanation: Bus is operational
v DEVBPLN
Response: This reference code and the 3120 reference
code that occurred before it require no service action
57FF3103 57FF3103
because SCSI bus 0 is now operational.
Explanation: Interface error
Response: Error occurred on SCSI bus 3. 57FF3141 57FF3141
v FI01140
v DEVBPLN 57FF3142 57FF3142
Explanation: Bus is operational
57FF3120 57FF3120 Response: This reference code and the 3122 reference
Explanation: Bus is not operational code that occurred before it require no service action
because SCSI bus 2 is now operational.
Response: Adding a device to SCSI bus 0 of the I/O
Adapter caused the bus to become not operational.
Remove the device. 57FF3143 57FF3143
Response: NOTE: If external devices are attached Explanation: System log entry only. No service action
check EXTSCSI and DEVTERM first. required.
Failing Item:
57FF4150 57FF4150
v FI02112
v STORIOA Explanation: I/O adapter detected PCI bus error
v FI01106 Response: If this event appears in a serviceable event
v FI01140 view, work with the failing item list found there. If this
event does not appear in a serviceable event view, no
service action is required.
57FF3401 57FF3401
If you are working with one of the card types below,
Explanation: Device backplane problem the adapter has mulitple physical parts. Choose the
Failing Item: card type to identify the physical parts of the storage
adapter.
v DEVBPLN
Card type 2BE1 (feature RAID enablement card for
embedded IOA) read the following: When working the
57FF3405 57FF3405 FRUs from the serviceable event or the failing item list
Explanation: An error occurred during task here, the embedded storage adapter (STORIOA) has
initialization for a removable media device. This SRC is three physical parts:
logged when an error occurs and the removable media v The embedded storage adapter on the I/O
device driver cannot determine the device type or backplane.
model. v The RAID enablement card.
Response: Perform the following: v The Battery charger and carrier card.
v Check the Product Activity Log for other entries that
indicate interface problems and work those See symbolic FRU FEATCRD for the location codes of
problems. the FRUs if they are not listed in the serviceable event
v Check the device firmware level and apply the latest or if you are working the failing item list here.
PTFs.
Card type 57CB (embedded IOA with 2BCF battery
v Check for LIC logs with major code 2E00. Contact
card for embedded IOA) read the following: When
your next level of support with the information you
working the FRUs from the serviceable event or the
have gathered.
failing item list here, the embedded storage adapter
Problem determination: IPL the IOP to retry the (STORIOA) has two physical parts:
device identification process. If the error persists then v The embedded storage adapter on the I/O
contact your service provider. backplane.
Failing Item: v The Battery charger and carrier card.
v PTFSRCH
See symbolic FRU FEATCRD for the location codes of
the FRUs if they are not listed in the serviceable event
57FF34FF 57FF34FF or if you are working the failing item list here.
Explanation: A device on this adapter is being
formatted. Wait for the formatting to complete. Card type 57CF (embedded IOAs on DASD backplane
with 2BC2 dual battery charger and carrier card for the
Failing Item: embedded IOAs) read the following: When working
v SVCDOCS
the FRUs from the serviceable event or the failing item Card type 57CF (embedded IOAs on DASD backplane
list here, the embedded storage adapters (STORIOA) with 2BC2 dual battery charger and carrier card for the
have two physical parts: embedded IOAs) read the following: When working
v The embedded storage adapter on the DASD the FRUs from the serviceable event or the failing item
backplane. list here, the embedded storage adapters (STORIOA)
have two physical parts:
v The dual battery charger and carrier card. To
determine which battery is connected to which v The embedded storage adapter on the DASD
embedded IOA use the bus number of the IOA with backplane.
symbolic FRU CACHBAT. v The dual battery charger and carrier card. To
determine which battery is connected to which
See symbolic FRU FEATCRD for the location code of embedded IOA use the bus number of the IOA with
the dual battery charger and carrier card if it is not symbolic FRU CACHBAT.
listed in the serviceable event or if you are working the
failing item list here. See symbolic FRU FEATCRD for the location code of
the dual battery charger and carrier card if it is not
Failing Item:
listed in the serviceable event or if you are working the
v BACKPLN failing item list here.
v STORIOA
Failing Item:
v BACKPLN
57FF4160 57FF4160
v STORIOA
Explanation: I/O adapter detected and recovered a
PCI bus error
57FF8008 57FF8008
Response: If this event appears in a serviceable event
Explanation: A permanent cache battery pack failure
view, work with the failing item list found there. If this
occurred
event does not appear in a serviceable event view, no
service action is required. Response: NOTE: Under a certain configuration, this
SRC may not represent an error that requires a service
If you are working with one of the card types below,
action. Depending on the configuration of the system,
the adapter has mulitple physical parts. Choose the
the Storage IOA may have been altered and/or the
card type to identify the physical parts of the storage
Storage IOA Cache may have been disabled to allow
adapter.
attachment of OEM Storage that emulates a Load
Card type 2BE1 (feature RAID enablement card for Source drive. If this is the case, this error will be posted
embedded IOA) read the following: When working the each time the IOA is IPLed and it can be ignored.
FRUs from the serviceable event or the failing item list
Failing Item:
here, the embedded storage adapter (STORIOA) has
three physical parts: v CACHBAT
v The embedded storage adapter on the I/O v STORIOA
backplane.
v The RAID enablement card. 57FF8009 57FF8009
v The Battery charger and carrier card. Explanation: Impending cache battery pack failure
See symbolic FRU FEATCRD for the location codes of Failing Item:
the FRUs if they are not listed in the serviceable event v CACHBAT
or if you are working the failing item list here.
57FF8100 57FF8100
Card type 57CB (embedded IOA with 2BCF battery
card for embedded IOA) read the following: When Explanation: Licensed Internal Code error
working the FRUs from the serviceable event or the
Failing Item:
failing item list here, the embedded storage adapter
(STORIOA) has two physical parts: v PTFSRCH
v The embedded storage adapter on the I/O v STORIOA
backplane.
v The Battery charger and carrier card. 57FF8130 57FF8130
Explanation: IOA detected recoverable device bus
See symbolic FRU FEATCRD for the location codes of
error
the FRUs if they are not listed in the serviceable event
or if you are working the failing item list here. Response: An error occurred on SCSI bus 0. No action
v SVCDOCS
57FF9002 57FF9002
Explanation: Device error
57FF8300 57FF8300
Response:
Explanation: IOA hardware error or PCI bus error
Failing Item:
Failing Item:
v IOPIP16
v STORIOA
v FI01105
v ANYBRDG
v STORIOA
v PTFSRCH
v FI01140
v BACKPLN
57FF8301 57FF8301
v FI01106
Explanation: Not valid condition in Licensed Internal
Code
57FF9008 57FF9008
Failing Item:
Explanation: I/O card does not support functions
v PTFSRCH
expected by devices
v STORIOA
Response:
57FF8400 57FF8400
57FF9010 57FF9010
Explanation: Licensed Internal Code error
Explanation: Cache data associated with attached
Failing Item: devices cannot be found
v PTFSRCH
Response:
Failing Item:
57FF8404 57FF8404
v IOPIP31
Explanation: System log entry only. No service action
required.
57FF9011 57FF9011
57FF9020 57FF9020
57FF9001 57FF9001
Explanation: Array not functional due to present
Explanation: Device configuration error
hardware configuration.
Response:
Response:
Failing Item:
Failing Item:
v IOPIP33
v IOPIP20
57FF9040 57FF9040
57FF9053 57FF9053
Explanation: Array protection temporarily suspended
Explanation: IOA resources not available due to
Response: No action required. Protection will be previous problems
automatically restarted.
Response: Take action on other reference codes which
have surfaced.
57FF9041 57FF9041
If you cannot get to SST or DST, and cannot perform a
Explanation: Background array parity check detected type A or B IPL, perform a type D IPL from removable
and corrected errors media. Look for Product Activity Log entries for other
reference codes and take action on them.
Response: Call your next level of support to report
the problem. Failing Item:
Failing Item: v SVCDOCS
v PTFSRCH
57FF9054 57FF9054
57FF9042 57FF9042 Explanation: IOA resources not available due to
previous problems
Explanation: An array parity error has been detected
and corrected Response: Power off the system and remove all new
or replacement disk units. IPL the system to DST. If
Response: Call your next level of support to report
you cannot perform a type A or B IPL, perform a type
the problem.
D IPL from removable media.
Failing Item:
Look for Product Activity Log entries for other
v NEXTLVL reference codes and take action on them.
Failing Item:
57FF9050 57FF9050
v SVCDOCS
Explanation: Required cache data cannot be located
for a disk unit.
57FF9070 57FF9070
Response:
Explanation: System log entry only. No service action
Failing Item: required.
v IOPIP30
57FF9071 57FF9071
57FF9051 57FF9051 Explanation: Link from IOA to auxiliary cache IOA
Explanation: Cache data exists for a missing or failed went operational
device Response: No service action required.
Response: If all configured units are missing, a 9054
reference code may appear in the product activity log.
If so, perform the action indicated for the 9054
reference code.
57FF9092 57FF9092
57FF9073 57FF9073
Explanation: Disk unit requires initialization before
Explanation: Incompatible or non-operational use.
auxiliary cache IOA attached
Response:
Response:
Failing Item:
Failing Item:
v IOPIP26
v IOPIP40
57FF9500 57FF9500
57FF9081 57FF9081
Explanation: Internal program error in driver code.
Explanation: Device error
Failing Item:
Failing Item:
v PTFSRCH
v FI01105
v STORIOA
57FF9902 57FF9902
Explanation: System log entry only. No service action
57FF9082 57FF9082
required.
Explanation: Device error
Response: 57FF9903 57FF9903
Failing Item: Explanation: Tape device information was logged.
v IOPIP16 Informational event, no service required.
v FI01105
v STORIOA 57FFC000 57FFC000
v FI01140 Explanation: System log entry only. No service action
v BACKPLN required.
v FI01106 Response: No action is required. This reference code
is logged for information only.
57FF9090 57FF9090
57FFC100 57FFC100
Explanation: Disk unit has been modified after the
last known status. Explanation: System log entry only. No service action
required.
Response: Re-IPL the system. If any reference codes
are surfaced, use the new reference code to resolve the Response: No action is required. This reference code
problem. is logged for information only.
If you cannot resolve the problem, contact your next
level of support. 57FFC402 57FFC402
Failing Item: Explanation: Licensed Internal Code error
v SVCDOCS Response: Ask your next level of support for
assistance.
57FF9091 57FF9091 Failing Item:
Explanation: Incorrect hardware configuration change v PTFSRCH
detected
Response: Re-IPL the system. If any reference codes
are surfaced, use the new reference code to resolve the
problem.
57FFFF3D 57FFFF3D
Explanation: I/O adapter detected a recoverable error
Failing Item:
v STORIOA
v ANYBRDG
57FFFF6D 57FFFF6D
Explanation: Recoverable system bus error
Failing Item:
v STORIOA
v ANYBRDG
v PTFSRCH
Response: No action required. This reference code is Explanation: Device Licensed Internal Code
logged for information only. Response: The device is not supported with the level
of code currently on the system. Contact your next
58B03100 58B03100 level of support.
58B0FFF4 58B0FFF4
58B04060 58B04060
Explanation: Disk device problem
Explanation: Multipath redundancy level reduced
Failing Item:
Response: A redundant disk unit connection has
failed. v DISKDRV
v STORIOA
Failing Item:
v SIP3153
58B0FFF5 58B0FFF5
v SASCABL
v SASEXP Explanation: Disk sector read error
Response: If this event appears in a serviceable event
58B04061 58B04061 view, work with the failing item list found there. If this
event does not appear in a serviceable event view, no
Explanation: Multipath redundancy level increased service action is required.
Response: A redundant disk unit connection has been Failing Item:
restored. No service action is required.
v DISKDRV
58B04100 58B04100
58B0FFF6 58B0FFF6
Explanation: Device bus fabric error
Explanation: Disk device detected recoverable error
Failing Item:
Response: If this event appears in a serviceable event
v SIP3152 view, work with the failing item list found there. If this
v SASCABL event does not appear in a serviceable event view, no
v SASEXP service action is required.
58B0FFFB 58B0FFFB
Explanation: SAS bus reset occurred
Response: No action required. This reference code is
logged for information only.
58B0FFFC 58B0FFFC
Explanation: Soft device bus error.
Response: If this event appears in a serviceable event
view, work with the failing item list found there. If this
event does not appear in a serviceable event view, no
service action is required.
Failing Item:
v SIP3250
v DISKDRV
v STORIOA
58B0FFFD 58B0FFFD
Explanation: Soft device bus error.
Response: If this event appears in a serviceable event
view, work with the failing item list found there. If this
event does not appear in a serviceable event view, no
service action is required.
Failing Item:
v SIP3250
v DISKDRV
v STORIOA
Response: No action required. This reference code is Explanation: Device Licensed Internal Code
logged for information only. Response: The device is not supported with the level
of code currently on the system. Contact your next
58B23100 58B23100 level of support.
58B2FFF4 58B2FFF4
58B24060 58B24060
Explanation: Disk device problem
Explanation: Multipath redundancy level reduced
Failing Item:
Response: A redundant disk unit connection has
failed. v DISKDRV
v STORIOA
Failing Item:
v SIP3153
58B2FFF5 58B2FFF5
v SASCABL
v SASEXP Explanation: Disk sector read error
Response: If this event appears in a serviceable event
58B24061 58B24061 view, work with the failing item list found there. If this
event does not appear in a serviceable event view, no
Explanation: Multipath redundancy level increased service action is required.
Response: A redundant disk unit connection has been Failing Item:
restored. No service action is required.
v DISKDRV
58B24100 58B24100
58B2FFF6 58B2FFF6
Explanation: Device bus fabric error
Explanation: Disk device detected recoverable error
Failing Item:
Response: If this event appears in a serviceable event
v SIP3152 view, work with the failing item list found there. If this
v SASCABL event does not appear in a serviceable event view, no
v SASEXP service action is required.
58B2FFFB 58B2FFFB
Explanation: SAS bus reset occurred
Response: No action required. This reference code is
logged for information only.
58B2FFFC 58B2FFFC
Explanation: Soft device bus error.
Response: If this event appears in a serviceable event
view, work with the failing item list found there. If this
event does not appear in a serviceable event view, no
service action is required.
Failing Item:
v SIP3250
v DISKDRV
v STORIOA
58B2FFFD 58B2FFFD
Explanation: Soft device bus error.
Response: If this event appears in a serviceable event
view, work with the failing item list found there. If this
event does not appear in a serviceable event view, no
service action is required.
Failing Item:
v SIP3250
v DISKDRV
v STORIOA
Response: No action required. This reference code is Explanation: Device Licensed Internal Code
logged for information only. Response: The device is not supported with the level
of code currently on the system. Contact your next
58B33100 58B33100 level of support.
58B3FFF4 58B3FFF4
58B34060 58B34060
Explanation: Disk device problem
Explanation: Multipath redundancy level reduced
Failing Item:
Response: A redundant disk unit connection has
failed. v DISKDRV
v STORIOA
Failing Item:
v SIP3153
58B3FFF5 58B3FFF5
v SASCABL
v SASEXP Explanation: Disk sector read error
Response: If this event appears in a serviceable event
58B34061 58B34061 view, work with the failing item list found there. If this
event does not appear in a serviceable event view, no
Explanation: Multipath redundancy level increased service action is required.
Response: A redundant disk unit connection has been Failing Item:
restored. No service action is required.
v DISKDRV
58B34100 58B34100
58B3FFF6 58B3FFF6
Explanation: Device bus fabric error
Explanation: Disk device detected recoverable error
Failing Item:
Response: If this event appears in a serviceable event
v SIP3152 view, work with the failing item list found there. If this
v SASCABL event does not appear in a serviceable event view, no
v SASEXP service action is required.
58B3FFFB 58B3FFFB
Explanation: SAS bus reset occurred
Response: No action required. This reference code is
logged for information only.
58B3FFFC 58B3FFFC
Explanation: Soft device bus error.
Response: If this event appears in a serviceable event
view, work with the failing item list found there. If this
event does not appear in a serviceable event view, no
service action is required.
Failing Item:
v SIP3250
v DISKDRV
v STORIOA
58B3FFFD 58B3FFFD
Explanation: Soft device bus error.
Response: If this event appears in a serviceable event
view, work with the failing item list found there. If this
event does not appear in a serviceable event view, no
service action is required.
Failing Item:
v SIP3250
v DISKDRV
v STORIOA
Response: No action required. This reference code is Explanation: Device Licensed Internal Code
logged for information only. Response: The device is not supported with the level
of code currently on the system. Contact your next
58B43100 58B43100 level of support.
58B4FFF4 58B4FFF4
58B44060 58B44060
Explanation: Disk device problem
Explanation: Multipath redundancy level reduced
Failing Item:
Response: A redundant disk unit connection has
failed. v DISKDRV
v STORIOA
Failing Item:
v SIP3153
58B4FFF5 58B4FFF5
v SASCABL
v SASEXP Explanation: Disk sector read error
Response: If this event appears in a serviceable event
58B44061 58B44061 view, work with the failing item list found there. If this
event does not appear in a serviceable event view, no
Explanation: Multipath redundancy level increased service action is required.
Response: A redundant disk unit connection has been Failing Item:
restored. No service action is required.
v DISKDRV
58B44100 58B44100
58B4FFF6 58B4FFF6
Explanation: Device bus fabric error
Explanation: Disk device detected recoverable error
Failing Item:
Response: If this event appears in a serviceable event
v SIP3152 view, work with the failing item list found there. If this
v SASCABL event does not appear in a serviceable event view, no
v SASEXP service action is required.
58B4FFFB 58B4FFFB
Explanation: SAS bus reset occurred
Response: No action required. This reference code is
logged for information only.
58B4FFFC 58B4FFFC
Explanation: Soft device bus error.
Response: If this event appears in a serviceable event
view, work with the failing item list found there. If this
event does not appear in a serviceable event view, no
service action is required.
Failing Item:
v SIP3250
v DISKDRV
v STORIOA
58B4FFFD 58B4FFFD
Explanation: Soft device bus error.
Response: If this event appears in a serviceable event
view, work with the failing item list found there. If this
event does not appear in a serviceable event view, no
service action is required.
Failing Item:
v SIP3250
v DISKDRV
v STORIOA
Response: No action required. This reference code is Explanation: Device Licensed Internal Code
logged for information only. Response: The device is not supported with the level
of code currently on the system. Contact your next
58B53100 58B53100 level of support.
58B5FFF4 58B5FFF4
58B54060 58B54060
Explanation: Disk device problem
Explanation: Multipath redundancy level reduced
Failing Item:
Response: A redundant disk unit connection has
failed. v DISKDRV
v STORIOA
Failing Item:
v SIP3153
58B5FFF5 58B5FFF5
v SASCABL
v SASEXP Explanation: Disk sector read error
Response: If this event appears in a serviceable event
58B54061 58B54061 view, work with the failing item list found there. If this
event does not appear in a serviceable event view, no
Explanation: Multipath redundancy level increased service action is required.
Response: A redundant disk unit connection has been Failing Item:
restored. No service action is required.
v DISKDRV
58B54100 58B54100
58B5FFF6 58B5FFF6
Explanation: Device bus fabric error
Explanation: Disk device detected recoverable error
Failing Item:
Response: If this event appears in a serviceable event
v SIP3152 view, work with the failing item list found there. If this
v SASCABL event does not appear in a serviceable event view, no
v SASEXP service action is required.
58B5FFFB 58B5FFFB
Explanation: SAS bus reset occurred
Response: No action required. This reference code is
logged for information only.
58B5FFFC 58B5FFFC
Explanation: Soft device bus error.
Response: If this event appears in a serviceable event
view, work with the failing item list found there. If this
event does not appear in a serviceable event view, no
service action is required.
Failing Item:
v SIP3250
v DISKDRV
v STORIOA
58B5FFFD 58B5FFFD
Explanation: Soft device bus error.
Response: If this event appears in a serviceable event
view, work with the failing item list found there. If this
event does not appear in a serviceable event view, no
service action is required.
Failing Item:
v SIP3250
v DISKDRV
v STORIOA
Response: No action required. This reference code is Explanation: Device Licensed Internal Code
logged for information only. Response: The device is not supported with the level
of code currently on the system. Contact your next
58B63100 58B63100 level of support.
58B6FFF4 58B6FFF4
58B64060 58B64060
Explanation: Disk device problem
Explanation: Multipath redundancy level reduced
Failing Item:
Response: A redundant disk unit connection has
failed. v DISKDRV
v STORIOA
Failing Item:
v SIP3153
58B6FFF5 58B6FFF5
v SASCABL
v SASEXP Explanation: Disk sector read error
Response: If this event appears in a serviceable event
58B64061 58B64061 view, work with the failing item list found there. If this
event does not appear in a serviceable event view, no
Explanation: Multipath redundancy level increased service action is required.
Response: A redundant disk unit connection has been Failing Item:
restored. No service action is required.
v DISKDRV
58B64100 58B64100
58B6FFF6 58B6FFF6
Explanation: Device bus fabric error
Explanation: Disk device detected recoverable error
Failing Item:
Response: If this event appears in a serviceable event
v SIP3152 view, work with the failing item list found there. If this
v SASCABL event does not appear in a serviceable event view, no
v SASEXP service action is required.
58B6FFFB 58B6FFFB
Explanation: SAS bus reset occurred
Response: No action required. This reference code is
logged for information only.
58B6FFFC 58B6FFFC
Explanation: Soft device bus error.
Response: If this event appears in a serviceable event
view, work with the failing item list found there. If this
event does not appear in a serviceable event view, no
service action is required.
Failing Item:
v SIP3250
v DISKDRV
v STORIOA
58B6FFFD 58B6FFFD
Explanation: Soft device bus error.
Response: If this event appears in a serviceable event
view, work with the failing item list found there. If this
event does not appear in a serviceable event view, no
service action is required.
Failing Item:
v SIP3250
v DISKDRV
v STORIOA
Note: Use this table to handle reference codes that might be displayed during a
type D IPL to install the operating system. If you are not performing a type D IPL
of the operating system, consult any error logs found in the serviceable event view.
If you cannot locate an error log in the serviceable event view that corresponds
with the failure, run a verification test for the tape unit.
1. Verify that the device has power.
2. Check the device for any error indications. Refer to the device service
information to resolve any error indications.
3. Clean the recording head in the tape device.
4. Attempt the failing operation again. Does the operation complete successfully?
Yes: You have corrected the problem. This ends the procedure.
No: Look at the 8 rightmost characters of the Data display for Function 11,
which represent the reference code. Find the reference code in the following
list.
v FI00872 v FI00871
v DEVTERM v FI01112
v SASCABL
59079101 59079101
Explanation: Fibre Channel interface error detected 59079200 59079200
Response: If the attached device is an external device, Explanation: Tape unit is not responding
do the following before exchanging any parts: Response: If the attached device is an external device,
1. Ensure that the Fibre Channel cable is correctly do the following before exchanging any parts:
connected to the ports. 1. Ensure that the device is powered on.
2. Clean the Fibre Channel connectors. 2. Ensure that the signal cable is seated correctly, and
3. If there is a switch or hub attached, verify that it is that there are no bent or damaged pins on the cable.
operational. 3. For a SCSI attached device ensure that a
4. If there is a gateway device attached, refer to the terminating plug is attached to the device end of
gateway device service documentation for the SCSI cable.
additional problem analysis procedures.
5. refer to the tape device service documentation for If the attached tape device is owned by a Virtual I/O
additional problem analysis procedures. Server partition refer to Troubleshooting the Virtual
I/O Server to determine the parts to replace.
If the attached tape device is owned by a Virtual I/O Failing Item:
Server partition refer to Troubleshooting the Virtual
v FI00871
I/O Server to determine the parts to replace.
v FI01112
Failing Item:
v FI00872
v FCIOA
v DEVTERM
v FCDEV
v FCCABLE
59079201 59079201
Explanation: Tape unit command timeout
59079102 59079102
Response: If the attached device is an external device,
Explanation: Gateway device detected a SCSI interface
do the following before exchanging any parts:
error
1. Ensure that the device is powered on.
Response: Use the gateway device service
2. If an interposer is required, make sure that it is
documentation to analyze the problem.
connected between the I/O processor and the SCSI
Failing Item: cable.
v FI00871 3. Ensure that the signal cable is seated correctly, and
v FCGATE that there are no bent or damaged pins on the SCSI
cable.
v FI00872
4. Ensure that a terminating plug is attached to the
v DEVTERM
device end of the SCSI cable.
5. If the attached tape device is owned by a Virtual
59079103 59079103 I/O Server partition it may be necessary to reset the
Explanation: Interface error detected by system or by virtual IOP to recover from the error.
tape unit Failing Item:
Response: If the attached device is an external tape v FI00871
device, do the following before exchanging any parts: v FI01112
1. Ensure that the SAS cable is correctly connected to v FI00872
the ports.
v DEVTERM
2. Ensure that the device has power.
v MEDIA
If the attached tape device is owned by a Virtual I/O
Server partition refer to Troubleshooting the Virtual
I/O Server to determine the parts to replace.
Failing Item:
Failing Item:
59079302 59079302
v FI00871
v FI01112 Explanation: Tape device failure or media error
Failing Item:
59079304 59079304
v FCGATE
v FCIOA Explanation: Tape unit failure
59079899 59079899
Explanation: Problem analysis completed, the problem
has been corrected.
Response: This reference code is used for ending
Online Problem Analysis when no problem was found
or the problem was corrected.
59079900 59079900
Explanation: Licensed Internal Code for tape unit was
not upgraded
Response: The I/O processor loading of Licensed
Internal Code (LIC) to the programmable tape unit was
not completed.
The tape unit will continue to operate with the
previous LIC. You may do either of the following:
v Wait for next IPL when the system will attempt to
load the LIC for the tape drive again.
v Perform TUPIP04 to reset the IOP and the tape unit.
When the IOP is reset, if the device has the wrong
level of LIC, the IOP will attempt to load the new
LIC.
Failing Item:
v USER
Note: Use this table to handle reference codes that might be displayed during a
type D IPL to install the operating system. If you are not performing a type D IPL
of the operating system, consult any error logs found in the serviceable event view.
If you cannot locate an error log in the serviceable event view that corresponds
with the failure, run a verification test for the tape unit.
1. Verify that the device has power.
2. Check the device for any error indications. Refer to the device service
information to resolve any error indications.
3. Clean the recording head in the tape device.
4. Attempt the failing operation again. Does the operation complete successfully?
Yes: You have corrected the problem. This ends the procedure.
No: Look at the 8 rightmost characters of the Data display for Function 11,
which represent the reference code. Find the reference code in the following
list.
v FI00872 v FI00871
v DEVTERM v FI01112
v SASCABL
62589101 62589101
Explanation: Fibre Channel interface error detected 62589200 62589200
Response: If the attached device is an external device, Explanation: Tape unit is not responding
do the following before exchanging any parts: Response: If the attached device is an external device,
1. Ensure that the Fibre Channel cable is correctly do the following before exchanging any parts:
connected to the ports. 1. Ensure that the device is powered on.
2. Clean the Fibre Channel connectors. 2. Ensure that the signal cable is seated correctly, and
3. If there is a switch or hub attached, verify that it is that there are no bent or damaged pins on the cable.
operational. 3. For a SCSI attached device ensure that a
4. If there is a gateway device attached, refer to the terminating plug is attached to the device end of
gateway device service documentation for the SCSI cable.
additional problem analysis procedures.
5. refer to the tape device service documentation for If the attached tape device is owned by a Virtual I/O
additional problem analysis procedures. Server partition refer to Troubleshooting the Virtual
I/O Server to determine the parts to replace.
If the attached tape device is owned by a Virtual I/O Failing Item:
Server partition refer to Troubleshooting the Virtual
v FI00871
I/O Server to determine the parts to replace.
v FI01112
Failing Item:
v FI00872
v FCIOA
v DEVTERM
v FCDEV
v FCCABLE
62589201 62589201
Explanation: Tape unit command timeout
62589102 62589102
Response: If the attached device is an external device,
Explanation: Gateway device detected a SCSI interface
do the following before exchanging any parts:
error
1. Ensure that the device is powered on.
Response: Use the gateway device service
2. If an interposer is required, make sure that it is
documentation to analyze the problem.
connected between the I/O processor and the SCSI
Failing Item: cable.
v FI00871 3. Ensure that the signal cable is seated correctly, and
v FCGATE that there are no bent or damaged pins on the SCSI
cable.
v FI00872
4. Ensure that a terminating plug is attached to the
v DEVTERM
device end of the SCSI cable.
5. If the attached tape device is owned by a Virtual
62589103 62589103 I/O Server partition it may be necessary to reset the
Explanation: Interface error detected by system or by virtual IOP to recover from the error.
tape unit Failing Item:
Response: If the attached device is an external tape v FI00871
device, do the following before exchanging any parts: v FI01112
1. Ensure that the SAS cable is correctly connected to v FI00872
the ports.
v DEVTERM
2. Ensure that the device has power.
v MEDIA
If the attached tape device is owned by a Virtual I/O
Server partition refer to Troubleshooting the Virtual
I/O Server to determine the parts to replace.
Failing Item:
Failing Item:
62589302 62589302
v FI00871
v FI01112 Explanation: Tape device failure or media error
Failing Item:
62589304 62589304
v FCGATE
v FCIOA Explanation: Tape unit failure
62589899 62589899
Explanation: Problem analysis completed, the problem
has been corrected.
Response: This reference code is used for ending
Online Problem Analysis when no problem was found
or the problem was corrected.
62589900 62589900
Explanation: Licensed Internal Code for tape unit was
not upgraded
Response: The I/O processor loading of Licensed
Internal Code (LIC) to the programmable tape unit was
not completed.
The tape unit will continue to operate with the
previous LIC. You may do either of the following:
v Wait for next IPL when the system will attempt to
load the LIC for the tape drive again.
v Perform TUPIP04 to reset the IOP and the tape unit.
When the IOP is reset, if the device has the wrong
level of LIC, the IOP will attempt to load the new
LIC.
Failing Item:
v USER
Note: Use this table to handle reference codes that might be displayed during a
type D IPL to install the operating system. If you are not performing a type D IPL
of the operating system, consult any error logs found in the serviceable event view.
If you cannot locate an error log in the serviceable event view that corresponds
with the failure, run a verification test for the tape unit.
1. Verify that the device has power.
2. Check the device for any error indications. Refer to the device service
information to resolve any error indications.
3. Clean the recording head in the tape device.
4. Attempt the failing operation again. Does the operation complete successfully?
Yes: You have corrected the problem. This ends the procedure.
No: Look at the 8 rightmost characters of the Data display for Function 11,
which represent the reference code. Find the reference code in the following
list.
v FI00872 v FI00871
v DEVTERM v FI01112
v SASCABL
62799101 62799101
Explanation: Fibre Channel interface error detected 62799200 62799200
Response: If the attached device is an external device, Explanation: Tape unit is not responding
do the following before exchanging any parts: Response: If the attached device is an external device,
1. Ensure that the Fibre Channel cable is correctly do the following before exchanging any parts:
connected to the ports. 1. Ensure that the device is powered on.
2. Clean the Fibre Channel connectors. 2. Ensure that the signal cable is seated correctly, and
3. If there is a switch or hub attached, verify that it is that there are no bent or damaged pins on the cable.
operational. 3. For a SCSI attached device ensure that a
4. If there is a gateway device attached, refer to the terminating plug is attached to the device end of
gateway device service documentation for the SCSI cable.
additional problem analysis procedures.
5. refer to the tape device service documentation for If the attached tape device is owned by a Virtual I/O
additional problem analysis procedures. Server partition refer to Troubleshooting the Virtual
I/O Server to determine the parts to replace.
If the attached tape device is owned by a Virtual I/O Failing Item:
Server partition refer to Troubleshooting the Virtual
v FI00871
I/O Server to determine the parts to replace.
v FI01112
Failing Item:
v FI00872
v FCIOA
v DEVTERM
v FCDEV
v FCCABLE
62799201 62799201
Explanation: Tape unit command timeout
62799102 62799102
Response: If the attached device is an external device,
Explanation: Gateway device detected a SCSI interface
do the following before exchanging any parts:
error
1. Ensure that the device is powered on.
Response: Use the gateway device service
2. If an interposer is required, make sure that it is
documentation to analyze the problem.
connected between the I/O processor and the SCSI
Failing Item: cable.
v FI00871 3. Ensure that the signal cable is seated correctly, and
v FCGATE that there are no bent or damaged pins on the SCSI
cable.
v FI00872
4. Ensure that a terminating plug is attached to the
v DEVTERM
device end of the SCSI cable.
5. If the attached tape device is owned by a Virtual
62799103 62799103 I/O Server partition it may be necessary to reset the
Explanation: Interface error detected by system or by virtual IOP to recover from the error.
tape unit Failing Item:
Response: If the attached device is an external tape v FI00871
device, do the following before exchanging any parts: v FI01112
1. Ensure that the SAS cable is correctly connected to v FI00872
the ports.
v DEVTERM
2. Ensure that the device has power.
v MEDIA
If the attached tape device is owned by a Virtual I/O
Server partition refer to Troubleshooting the Virtual
I/O Server to determine the parts to replace.
Failing Item:
Failing Item:
62799302 62799302
v FI00871
v FI01112 Explanation: Tape device failure or media error
Failing Item:
62799304 62799304
v FCGATE
v FCIOA Explanation: Tape unit failure
62799899 62799899
Explanation: Problem analysis completed, the problem
has been corrected.
Response: This reference code is used for ending
Online Problem Analysis when no problem was found
or the problem was corrected.
62799900 62799900
Explanation: Licensed Internal Code for tape unit was
not upgraded
Response: The I/O processor loading of Licensed
Internal Code (LIC) to the programmable tape unit was
not completed.
The tape unit will continue to operate with the
previous LIC. You may do either of the following:
v Wait for next IPL when the system will attempt to
load the LIC for the tape drive again.
v Perform TUPIP04 to reset the IOP and the tape unit.
When the IOP is reset, if the device has the wrong
level of LIC, the IOP will attempt to load the new
LIC.
Failing Item:
v USER
Notes:
1. If the system is available, use online diagnostic tests when possible.
2. Use the Hardware Service Manager (HSM) verify function (via DST or SST)
and verify that the unit is operating correctly.
3. Search the problem log (WRKPRB) for a recent optical storage entry that might
assist in analyzing the problem. The WRKPRB entry will provide a reference
code that can be found in the following table.
If the system is available, attempt the failing operation again with an optical media
that is known to be good. Does the operation complete successfully?
Yes: The original optical media may be defective, or the problem may be
intermittent. Attempt the failing operation again with the original optical media
to verify. This ends the procedure.
No: Look at the 8 rightmost characters of the Data display for word 1. These 8
characters are the reference code. Find the reference code in the following table.
v FI00870
6320C000 6320C000
Explanation: System log entry only, no service action
6320C022 6320C022
required
Explanation: Unable to determine all device
Response: No action is required. This reference code
capabilities. Reported media support may be
is logged for information only.
inaccurate. Function may be reduced.
Response: No action is required. This reference code
6320C002 6320C002
is logged for information only.
Explanation: SCSI Selection or Reselection timeout
Problem determination:
occurred
v If this device is a client virtual optical device
Failing Item:
1. If no function reduction exists, no action is
v FI00870 required.
v CNVTCRD Note: Inaccuracies in media support reporting is
v FI01106 not likely to cause a functional problem.
v STORIOA 2. Verify that the backing device on the server is
v MEDIA varied on, operational, and not in exclusive use
by another partition . Once these things are
v FI01141
verified, IPL the virtual IOP on the client
v FI01140 partition or vary the server partition's NWSD off
and on.
6320C010 6320C010 3. Ensure that the latest optical LIC PTFs have been
applied to both the client and server partitions.
Explanation: Undefined sense key returned by device
v If this device is NOT a client virtual optical device
Failing Item: 1. If no function reduction exists, no action is
v FI00870 required.
2. This is likely a secondary error. Other PAL entries
6320C020 6320C020 logged at approximately the same time as this
one may explain the problem (e.g., interface
Explanation: Configuration error errors may have prevented identification of
Failing Item: device characteristics.)
v FI01106
v STORIOA 6320C332 6320C332
Notes:
1. If the system is available, use online diagnostic tests when possible.
2. Use the Hardware Service Manager (HSM) verify function (via DST or SST)
and verify that the unit is operating correctly.
3. Search the problem log (WRKPRB) for a recent optical storage entry that might
assist in analyzing the problem. The WRKPRB entry will provide a reference
code that can be found in the following table.
If the system is available, attempt the failing operation again with an optical media
that is known to be good. Does the operation complete successfully?
Yes: The original optical media may be defective, or the problem may be
intermittent. Attempt the failing operation again with the original optical media
to verify. This ends the procedure.
No: Look at the 8 rightmost characters of the Data display for word 1. These 8
characters are the reference code. Find the reference code in the following table.
v FI00870
6321C000 6321C000
Explanation: System log entry only, no service action
6321C022 6321C022
required
Explanation: Unable to determine all device
Response: No action is required. This reference code
capabilities. Reported media support may be
is logged for information only.
inaccurate. Function may be reduced.
Response: No action is required. This reference code
6321C002 6321C002
is logged for information only.
Explanation: SCSI Selection or Reselection timeout
Problem determination:
occurred
v If this device is a client virtual optical device
Failing Item:
1. If no function reduction exists, no action is
v FI00870 required.
v CNVTCRD Note: Inaccuracies in media support reporting is
v FI01106 not likely to cause a functional problem.
v STORIOA 2. Verify that the backing device on the server is
v MEDIA varied on, operational, and not in exclusive use
by another partition . Once these things are
v FI01141
verified, IPL the virtual IOP on the client
v FI01140 partition or vary the server partition's NWSD off
and on.
6321C010 6321C010 3. Ensure that the latest optical LIC PTFs have been
applied to both the client and server partitions.
Explanation: Undefined sense key returned by device
v If this device is NOT a client virtual optical device
Failing Item: 1. If no function reduction exists, no action is
v FI00870 required.
2. This is likely a secondary error. Other PAL entries
6321C020 6321C020 logged at approximately the same time as this
one may explain the problem (e.g., interface
Explanation: Configuration error errors may have prevented identification of
Failing Item: device characteristics.)
v FI01106
v STORIOA 6321C332 6321C332
632BCFC5 632BCFC5
Explanation: Error reading virtual optical volume
632CC002 632CC002
632CC023 632CC023
Explanation: SCSI Selection or Reselection timeout
occurred Explanation: Unable to determine all device
capabilities or device characteristics are not supported
Response: Refer to the hosting partition for problem with the current LIC. Writes will be blocked for this
analysis. device. If a write is attempted, the device will be
marked failed.
632CC010 632CC010 Response: No action is required. This reference code
Explanation: Undefined sense key returned by device is logged for information only.
Notes:
1. If the system is available, use online diagnostic tests when possible.
2. Use the Hardware Service Manager (HSM) verify function (via DST or SST)
and verify that the unit is operating correctly.
3. Search the problem log (WRKPRB) for a recent optical storage entry that might
assist in analyzing the problem. The WRKPRB entry will provide a reference
code that can be found in the following table.
If the system is available, attempt the failing operation again with an optical media
that is known to be good. Does the operation complete successfully?
Yes: The original optical media may be defective, or the problem may be
intermittent. Attempt the failing operation again with the original optical media
to verify. This ends the procedure.
No: Look at the 8 rightmost characters of the Data display for word 1. These 8
characters are the reference code. Find the reference code in the following table.
v FI00870
6330C000 6330C000
Explanation: System log entry only, no service action
6330C022 6330C022
required
Explanation: Unable to determine all device
Response: No action is required. This reference code
capabilities. Reported media support may be
is logged for information only.
inaccurate. Function may be reduced.
Response: No action is required. This reference code
6330C002 6330C002
is logged for information only.
Explanation: SCSI Selection or Reselection timeout
Problem determination:
occurred
v If this device is a client virtual optical device
Failing Item:
1. If no function reduction exists, no action is
v FI00870 required.
v CNVTCRD Note: Inaccuracies in media support reporting is
v FI01106 not likely to cause a functional problem.
v STORIOA 2. Verify that the backing device on the server is
v MEDIA varied on, operational, and not in exclusive use
by another partition . Once these things are
v FI01141
verified, IPL the virtual IOP on the client
v FI01140 partition or vary the server partition's NWSD off
and on.
6330C010 6330C010 3. Ensure that the latest optical LIC PTFs have been
applied to both the client and server partitions.
Explanation: Undefined sense key returned by device
v If this device is NOT a client virtual optical device
Failing Item: 1. If no function reduction exists, no action is
v FI00870 required.
2. This is likely a secondary error. Other PAL entries
6330C020 6330C020 logged at approximately the same time as this
one may explain the problem (e.g., interface
Explanation: Configuration error errors may have prevented identification of
Failing Item: device characteristics.)
v FI01106
v STORIOA 6330C332 6330C332
Notes:
1. If the system is available, use online diagnostic tests when possible.
2. Use the Hardware Service Manager (HSM) verify function (via DST or SST)
and verify that the unit is operating correctly.
3. Search the problem log (WRKPRB) for a recent optical storage entry that might
assist in analyzing the problem. The WRKPRB entry will provide a reference
code that can be found in the following table.
If the system is available, attempt the failing operation again with an optical media
that is known to be good. Does the operation complete successfully?
Yes: The original optical media may be defective, or the problem may be
intermittent. Attempt the failing operation again with the original optical media
to verify. This ends the procedure.
No: Look at the 8 rightmost characters of the Data display for word 1. These 8
characters are the reference code. Find the reference code in the following table.
v FI00870
6331C000 6331C000
Explanation: System log entry only, no service action
6331C022 6331C022
required
Explanation: Unable to determine all device
Response: No action is required. This reference code
capabilities. Reported media support may be
is logged for information only.
inaccurate. Function may be reduced.
Response: No action is required. This reference code
6331C002 6331C002
is logged for information only.
Explanation: SCSI Selection or Reselection timeout
Problem determination:
occurred
v If this device is a client virtual optical device
Failing Item:
1. If no function reduction exists, no action is
v FI00870 required.
v CNVTCRD Note: Inaccuracies in media support reporting is
v FI01106 not likely to cause a functional problem.
v STORIOA 2. Verify that the backing device on the server is
v MEDIA varied on, operational, and not in exclusive use
by another partition . Once these things are
v FI01141
verified, IPL the virtual IOP on the client
v FI01140 partition or vary the server partition's NWSD off
and on.
6331C010 6331C010 3. Ensure that the latest optical LIC PTFs have been
applied to both the client and server partitions.
Explanation: Undefined sense key returned by device
v If this device is NOT a client virtual optical device
Failing Item: 1. If no function reduction exists, no action is
v FI00870 required.
2. This is likely a secondary error. Other PAL entries
6331C020 6331C020 logged at approximately the same time as this
one may explain the problem (e.g., interface
Explanation: Configuration error errors may have prevented identification of
Failing Item: device characteristics.)
v FI01106
v STORIOA 6331C332 6331C332
Notes:
1. If the system is available, use online diagnostic tests when possible.
2. Use the Hardware Service Manager (HSM) verify function (via DST or SST)
and verify that the unit is operating correctly.
3. Search the problem log (WRKPRB) for a recent optical storage entry that might
assist in analyzing the problem. The WRKPRB entry will provide a reference
code that can be found in the following table.
If the system is available, attempt the failing operation again with an optical media
that is known to be good. Does the operation complete successfully?
Yes: The original optical media may be defective, or the problem may be
intermittent. Attempt the failing operation again with the original optical media
to verify. This ends the procedure.
No: Look at the 8 rightmost characters of the Data display for word 1. These 8
characters are the reference code. Find the reference code in the following table.
v FI00870
6333C000 6333C000
Explanation: System log entry only, no service action
6333C022 6333C022
required
Explanation: Unable to determine all device
Response: No action is required. This reference code
capabilities. Reported media support may be
is logged for information only.
inaccurate. Function may be reduced.
Response: No action is required. This reference code
6333C002 6333C002
is logged for information only.
Explanation: SCSI Selection or Reselection timeout
Problem determination:
occurred
v If this device is a client virtual optical device
Failing Item:
1. If no function reduction exists, no action is
v FI00870 required.
v CNVTCRD Note: Inaccuracies in media support reporting is
v FI01106 not likely to cause a functional problem.
v STORIOA 2. Verify that the backing device on the server is
v MEDIA varied on, operational, and not in exclusive use
by another partition . Once these things are
v FI01141
verified, IPL the virtual IOP on the client
v FI01140 partition or vary the server partition's NWSD off
and on.
6333C010 6333C010 3. Ensure that the latest optical LIC PTFs have been
applied to both the client and server partitions.
Explanation: Undefined sense key returned by device
v If this device is NOT a client virtual optical device
Failing Item: 1. If no function reduction exists, no action is
v FI00870 required.
2. This is likely a secondary error. Other PAL entries
6333C020 6333C020 logged at approximately the same time as this
one may explain the problem (e.g., interface
Explanation: Configuration error errors may have prevented identification of
Failing Item: device characteristics.)
v FI01106
v STORIOA 6333C332 6333C332
Notes:
1. If the system is available, use online diagnostic tests when possible.
2. Use the Hardware Service Manager (HSM) verify function (via DST or SST)
and verify that the unit is operating correctly.
3. Search the problem log (WRKPRB) for a recent optical storage entry that might
assist in analyzing the problem. The WRKPRB entry will provide a reference
code that can be found in the following table.
If the system is available, attempt the failing operation again with an optical media
that is known to be good. Does the operation complete successfully?
Yes: The original optical media may be defective, or the problem may be
intermittent. Attempt the failing operation again with the original optical media
to verify. This ends the procedure.
No: Look at the 8 rightmost characters of the Data display for word 1. These 8
characters are the reference code. Find the reference code in the following table.
v FI00870
6336C000 6336C000
Explanation: System log entry only, no service action
6336C022 6336C022
required
Explanation: Unable to determine all device
Response: No action is required. This reference code
capabilities. Reported media support may be
is logged for information only.
inaccurate. Function may be reduced.
Response: No action is required. This reference code
6336C002 6336C002
is logged for information only.
Explanation: SCSI Selection or Reselection timeout
Problem determination:
occurred
v If this device is a client virtual optical device
Failing Item:
1. If no function reduction exists, no action is
v FI00870 required.
v CNVTCRD Note: Inaccuracies in media support reporting is
v FI01106 not likely to cause a functional problem.
v STORIOA 2. Verify that the backing device on the server is
v MEDIA varied on, operational, and not in exclusive use
by another partition . Once these things are
v FI01141
verified, IPL the virtual IOP on the client
v FI01140 partition or vary the server partition's NWSD off
and on.
6336C010 6336C010 3. Ensure that the latest optical LIC PTFs have been
applied to both the client and server partitions.
Explanation: Undefined sense key returned by device
v If this device is NOT a client virtual optical device
Failing Item: 1. If no function reduction exists, no action is
v FI00870 required.
2. This is likely a secondary error. Other PAL entries
6336C020 6336C020 logged at approximately the same time as this
one may explain the problem (e.g., interface
Explanation: Configuration error errors may have prevented identification of
Failing Item: device characteristics.)
v FI01106
v STORIOA 6336C332 6336C332
Notes:
1. If the system is available, use online diagnostic tests when possible.
2. Use the Hardware Service Manager (HSM) verify function (via DST or SST)
and verify that the unit is operating correctly.
3. Search the problem log (WRKPRB) for a recent optical storage entry that might
assist in analyzing the problem. The WRKPRB entry will provide a reference
code that can be found in the following table.
If the system is available, attempt the failing operation again with an optical media
that is known to be good. Does the operation complete successfully?
Yes: The original optical media may be defective, or the problem may be
intermittent. Attempt the failing operation again with the original optical media
to verify. This ends the procedure.
No: Look at the 8 rightmost characters of the Data display for word 1. These 8
characters are the reference code. Find the reference code in the following table.
v FI00870
6337C000 6337C000
Explanation: System log entry only, no service action
6337C022 6337C022
required
Explanation: Unable to determine all device
Response: No action is required. This reference code
capabilities. Reported media support may be
is logged for information only.
inaccurate. Function may be reduced.
Response: No action is required. This reference code
6337C002 6337C002
is logged for information only.
Explanation: SCSI Selection or Reselection timeout
Problem determination:
occurred
v If this device is a client virtual optical device
Failing Item:
1. If no function reduction exists, no action is
v FI00870 required.
v CNVTCRD Note: Inaccuracies in media support reporting is
v FI01106 not likely to cause a functional problem.
v STORIOA 2. Verify that the backing device on the server is
v MEDIA varied on, operational, and not in exclusive use
by another partition . Once these things are
v FI01141
verified, IPL the virtual IOP on the client
v FI01140 partition or vary the server partition's NWSD off
and on.
6337C010 6337C010 3. Ensure that the latest optical LIC PTFs have been
applied to both the client and server partitions.
Explanation: Undefined sense key returned by device
v If this device is NOT a client virtual optical device
Failing Item: 1. If no function reduction exists, no action is
v FI00870 required.
2. This is likely a secondary error. Other PAL entries
6337C020 6337C020 logged at approximately the same time as this
one may explain the problem (e.g., interface
Explanation: Configuration error errors may have prevented identification of
Failing Item: device characteristics.)
v FI01106
v STORIOA 6337C332 6337C332
Note: Use this table to handle reference codes that might be displayed during a
type D IPL to install the operating system. If you are not performing a type D IPL
of the operating system, consult any error logs found in the serviceable event view.
If you cannot locate an error log in the serviceable event view that corresponds
with the failure, run a verification test for the tape unit.
1. Verify that the device has power.
2. Check the device for any error indications. Refer to the device service
information to resolve any error indications.
3. Clean the recording head in the tape device.
4. Attempt the failing operation again. Does the operation complete successfully?
Yes: You have corrected the problem. This ends the procedure.
No: Look at the 8 rightmost characters of the Data display for Function 11,
which represent the reference code. Find the reference code in the following
list.
v FI00872 v FI00871
v DEVTERM v FI01112
v SASCABL
63829101 63829101
Explanation: Fibre Channel interface error detected 63829200 63829200
Response: If the attached device is an external device, Explanation: Tape unit is not responding
do the following before exchanging any parts: Response: If the attached device is an external device,
1. Ensure that the Fibre Channel cable is correctly do the following before exchanging any parts:
connected to the ports. 1. Ensure that the device is powered on.
2. Clean the Fibre Channel connectors. 2. Ensure that the signal cable is seated correctly, and
3. If there is a switch or hub attached, verify that it is that there are no bent or damaged pins on the cable.
operational. 3. For a SCSI attached device ensure that a
4. If there is a gateway device attached, refer to the terminating plug is attached to the device end of
gateway device service documentation for the SCSI cable.
additional problem analysis procedures.
5. refer to the tape device service documentation for If the attached tape device is owned by a Virtual I/O
additional problem analysis procedures. Server partition refer to Troubleshooting the Virtual
I/O Server to determine the parts to replace.
If the attached tape device is owned by a Virtual I/O Failing Item:
Server partition refer to Troubleshooting the Virtual
v FI00871
I/O Server to determine the parts to replace.
v FI01112
Failing Item:
v FI00872
v FCIOA
v DEVTERM
v FCDEV
v FCCABLE
63829201 63829201
Explanation: Tape unit command timeout
63829102 63829102
Response: If the attached device is an external device,
Explanation: Gateway device detected a SCSI interface
do the following before exchanging any parts:
error
1. Ensure that the device is powered on.
Response: Use the gateway device service
2. If an interposer is required, make sure that it is
documentation to analyze the problem.
connected between the I/O processor and the SCSI
Failing Item: cable.
v FI00871 3. Ensure that the signal cable is seated correctly, and
v FCGATE that there are no bent or damaged pins on the SCSI
cable.
v FI00872
4. Ensure that a terminating plug is attached to the
v DEVTERM
device end of the SCSI cable.
5. If the attached tape device is owned by a Virtual
63829103 63829103 I/O Server partition it may be necessary to reset the
Explanation: Interface error detected by system or by virtual IOP to recover from the error.
tape unit Failing Item:
Response: If the attached device is an external tape v FI00871
device, do the following before exchanging any parts: v FI01112
1. Ensure that the SAS cable is correctly connected to v FI00872
the ports.
v DEVTERM
2. Ensure that the device has power.
v MEDIA
If the attached tape device is owned by a Virtual I/O
Server partition refer to Troubleshooting the Virtual
I/O Server to determine the parts to replace.
Failing Item:
Failing Item:
63829302 63829302
v FI00871
v FI01112 Explanation: Tape device failure or media error
Failing Item:
63829304 63829304
v FCGATE
v FCIOA Explanation: Tape unit failure
63829899 63829899
Explanation: Problem analysis completed, the problem
has been corrected.
Response: This reference code is used for ending
Online Problem Analysis when no problem was found
or the problem was corrected.
63829900 63829900
Explanation: Licensed Internal Code for tape unit was
not upgraded
Response: The I/O processor loading of Licensed
Internal Code (LIC) to the programmable tape unit was
not completed.
The tape unit will continue to operate with the
previous LIC. You may do either of the following:
v Wait for next IPL when the system will attempt to
load the LIC for the tape drive again.
v Perform TUPIP04 to reset the IOP and the tape unit.
When the IOP is reset, if the device has the wrong
level of LIC, the IOP will attempt to load the new
LIC.
Failing Item:
v USER
Note: Use this table to handle reference codes that might be displayed during a
type D IPL to install the operating system. If you are not performing a type D IPL
of the operating system, consult any error logs found in the serviceable event view.
If you cannot locate an error log in the serviceable event view that corresponds
with the failure, run a verification test for the tape unit.
1. Verify that the device has power.
2. Check the device for any error indications. Refer to the device service
information to resolve any error indications.
3. Clean the recording head in the tape device.
4. Attempt the failing operation again. Does the operation complete successfully?
Yes: You have corrected the problem. This ends the procedure.
No: Look at the 8 rightmost characters of the Data display for Function 11,
which represent the reference code. Find the reference code in the following
list.
v FI00872 v FI00871
v DEVTERM v FI01112
v SASCABL
63839101 63839101
Explanation: Fibre Channel interface error detected 63839200 63839200
Response: If the attached device is an external device, Explanation: Tape unit is not responding
do the following before exchanging any parts: Response: If the attached device is an external device,
1. Ensure that the Fibre Channel cable is correctly do the following before exchanging any parts:
connected to the ports. 1. Ensure that the device is powered on.
2. Clean the Fibre Channel connectors. 2. Ensure that the signal cable is seated correctly, and
3. If there is a switch or hub attached, verify that it is that there are no bent or damaged pins on the cable.
operational. 3. For a SCSI attached device ensure that a
4. If there is a gateway device attached, refer to the terminating plug is attached to the device end of
gateway device service documentation for the SCSI cable.
additional problem analysis procedures.
5. refer to the tape device service documentation for If the attached tape device is owned by a Virtual I/O
additional problem analysis procedures. Server partition refer to Troubleshooting the Virtual
I/O Server to determine the parts to replace.
If the attached tape device is owned by a Virtual I/O Failing Item:
Server partition refer to Troubleshooting the Virtual
v FI00871
I/O Server to determine the parts to replace.
v FI01112
Failing Item:
v FI00872
v FCIOA
v DEVTERM
v FCDEV
v FCCABLE
63839201 63839201
Explanation: Tape unit command timeout
63839102 63839102
Response: If the attached device is an external device,
Explanation: Gateway device detected a SCSI interface
do the following before exchanging any parts:
error
1. Ensure that the device is powered on.
Response: Use the gateway device service
2. If an interposer is required, make sure that it is
documentation to analyze the problem.
connected between the I/O processor and the SCSI
Failing Item: cable.
v FI00871 3. Ensure that the signal cable is seated correctly, and
v FCGATE that there are no bent or damaged pins on the SCSI
cable.
v FI00872
4. Ensure that a terminating plug is attached to the
v DEVTERM
device end of the SCSI cable.
5. If the attached tape device is owned by a Virtual
63839103 63839103 I/O Server partition it may be necessary to reset the
Explanation: Interface error detected by system or by virtual IOP to recover from the error.
tape unit Failing Item:
Response: If the attached device is an external tape v FI00871
device, do the following before exchanging any parts: v FI01112
1. Ensure that the SAS cable is correctly connected to v FI00872
the ports.
v DEVTERM
2. Ensure that the device has power.
v MEDIA
If the attached tape device is owned by a Virtual I/O
Server partition refer to Troubleshooting the Virtual
I/O Server to determine the parts to replace.
Failing Item:
Failing Item:
63839302 63839302
v FI00871
v FI01112 Explanation: Tape device failure or media error
Failing Item:
63839304 63839304
v FCGATE
v FCIOA Explanation: Tape unit failure
63839899 63839899
Explanation: Problem analysis completed, the problem
has been corrected.
Response: This reference code is used for ending
Online Problem Analysis when no problem was found
or the problem was corrected.
63839900 63839900
Explanation: Licensed Internal Code for tape unit was
not upgraded
Response: The I/O processor loading of Licensed
Internal Code (LIC) to the programmable tape unit was
not completed.
The tape unit will continue to operate with the
previous LIC. You may do either of the following:
v Wait for next IPL when the system will attempt to
load the LIC for the tape drive again.
v Perform TUPIP04 to reset the IOP and the tape unit.
When the IOP is reset, if the device has the wrong
level of LIC, the IOP will attempt to load the new
LIC.
Failing Item:
v USER
Note: Use this table to handle reference codes that might be displayed during a
type D IPL to install the operating system. If you are not performing a type D IPL
of the operating system, consult any error logs found in the serviceable event view.
If you cannot locate an error log in the serviceable event view that corresponds
with the failure, run a verification test for the tape unit.
1. Verify that the device has power.
2. Check the device for any error indications. Refer to the device service
information to resolve any error indications.
3. Clean the recording head in the tape device.
4. Attempt the failing operation again. Does the operation complete successfully?
Yes: You have corrected the problem. This ends the procedure.
No: Look at the 8 rightmost characters of the Data display for Function 11,
which represent the reference code. Find the reference code in the following
list.
v FI00872 v FI00871
v DEVTERM v FI01112
v SASCABL
63849101 63849101
Explanation: Fibre Channel interface error detected 63849200 63849200
Response: If the attached device is an external device, Explanation: Tape unit is not responding
do the following before exchanging any parts: Response: If the attached device is an external device,
1. Ensure that the Fibre Channel cable is correctly do the following before exchanging any parts:
connected to the ports. 1. Ensure that the device is powered on.
2. Clean the Fibre Channel connectors. 2. Ensure that the signal cable is seated correctly, and
3. If there is a switch or hub attached, verify that it is that there are no bent or damaged pins on the cable.
operational. 3. For a SCSI attached device ensure that a
4. If there is a gateway device attached, refer to the terminating plug is attached to the device end of
gateway device service documentation for the SCSI cable.
additional problem analysis procedures.
5. refer to the tape device service documentation for If the attached tape device is owned by a Virtual I/O
additional problem analysis procedures. Server partition refer to Troubleshooting the Virtual
I/O Server to determine the parts to replace.
If the attached tape device is owned by a Virtual I/O Failing Item:
Server partition refer to Troubleshooting the Virtual
v FI00871
I/O Server to determine the parts to replace.
v FI01112
Failing Item:
v FI00872
v FCIOA
v DEVTERM
v FCDEV
v FCCABLE
63849201 63849201
Explanation: Tape unit command timeout
63849102 63849102
Response: If the attached device is an external device,
Explanation: Gateway device detected a SCSI interface
do the following before exchanging any parts:
error
1. Ensure that the device is powered on.
Response: Use the gateway device service
2. If an interposer is required, make sure that it is
documentation to analyze the problem.
connected between the I/O processor and the SCSI
Failing Item: cable.
v FI00871 3. Ensure that the signal cable is seated correctly, and
v FCGATE that there are no bent or damaged pins on the SCSI
cable.
v FI00872
4. Ensure that a terminating plug is attached to the
v DEVTERM
device end of the SCSI cable.
5. If the attached tape device is owned by a Virtual
63849103 63849103 I/O Server partition it may be necessary to reset the
Explanation: Interface error detected by system or by virtual IOP to recover from the error.
tape unit Failing Item:
Response: If the attached device is an external tape v FI00871
device, do the following before exchanging any parts: v FI01112
1. Ensure that the SAS cable is correctly connected to v FI00872
the ports.
v DEVTERM
2. Ensure that the device has power.
v MEDIA
If the attached tape device is owned by a Virtual I/O
Server partition refer to Troubleshooting the Virtual
I/O Server to determine the parts to replace.
Failing Item:
Failing Item:
63849302 63849302
v FI00871
v FI01112 Explanation: Tape device failure or media error
Failing Item:
63849304 63849304
v FCGATE
v FCIOA Explanation: Tape unit failure
63849899 63849899
Explanation: Problem analysis completed, the problem
has been corrected.
Response: This reference code is used for ending
Online Problem Analysis when no problem was found
or the problem was corrected.
63849900 63849900
Explanation: Licensed Internal Code for tape unit was
not upgraded
Response: The I/O processor loading of Licensed
Internal Code (LIC) to the programmable tape unit was
not completed.
The tape unit will continue to operate with the
previous LIC. You may do either of the following:
v Wait for next IPL when the system will attempt to
load the LIC for the tape drive again.
v Perform TUPIP04 to reset the IOP and the tape unit.
When the IOP is reset, if the device has the wrong
level of LIC, the IOP will attempt to load the new
LIC.
Failing Item:
v USER
Note: Use this table to handle reference codes that might be displayed during a
type D IPL to install the operating system. If you are not performing a type D IPL
of the operating system, consult any error logs found in the serviceable event view.
If you cannot locate an error log in the serviceable event view that corresponds
with the failure, run a verification test for the tape unit.
1. Verify that the device has power.
2. Check the device for any error indications. Refer to the device service
information to resolve any error indications.
3. Clean the recording head in the tape device.
4. Attempt the failing operation again. Does the operation complete successfully?
Yes: You have corrected the problem. This ends the procedure.
No: Look at the 8 rightmost characters of the Data display for Function 11,
which represent the reference code. Find the reference code in the following
list.
v FI00872 v FI00871
v DEVTERM v FI01112
v SASCABL
63869101 63869101
Explanation: Fibre Channel interface error detected 63869200 63869200
Response: If the attached device is an external device, Explanation: Tape unit is not responding
do the following before exchanging any parts: Response: If the attached device is an external device,
1. Ensure that the Fibre Channel cable is correctly do the following before exchanging any parts:
connected to the ports. 1. Ensure that the device is powered on.
2. Clean the Fibre Channel connectors. 2. Ensure that the signal cable is seated correctly, and
3. If there is a switch or hub attached, verify that it is that there are no bent or damaged pins on the cable.
operational. 3. For a SCSI attached device ensure that a
4. If there is a gateway device attached, refer to the terminating plug is attached to the device end of
gateway device service documentation for the SCSI cable.
additional problem analysis procedures.
5. refer to the tape device service documentation for If the attached tape device is owned by a Virtual I/O
additional problem analysis procedures. Server partition refer to Troubleshooting the Virtual
I/O Server to determine the parts to replace.
If the attached tape device is owned by a Virtual I/O Failing Item:
Server partition refer to Troubleshooting the Virtual
v FI00871
I/O Server to determine the parts to replace.
v FI01112
Failing Item:
v FI00872
v FCIOA
v DEVTERM
v FCDEV
v FCCABLE
63869201 63869201
Explanation: Tape unit command timeout
63869102 63869102
Response: If the attached device is an external device,
Explanation: Gateway device detected a SCSI interface
do the following before exchanging any parts:
error
1. Ensure that the device is powered on.
Response: Use the gateway device service
2. If an interposer is required, make sure that it is
documentation to analyze the problem.
connected between the I/O processor and the SCSI
Failing Item: cable.
v FI00871 3. Ensure that the signal cable is seated correctly, and
v FCGATE that there are no bent or damaged pins on the SCSI
cable.
v FI00872
4. Ensure that a terminating plug is attached to the
v DEVTERM
device end of the SCSI cable.
5. If the attached tape device is owned by a Virtual
63869103 63869103 I/O Server partition it may be necessary to reset the
Explanation: Interface error detected by system or by virtual IOP to recover from the error.
tape unit Failing Item:
Response: If the attached device is an external tape v FI00871
device, do the following before exchanging any parts: v FI01112
1. Ensure that the SAS cable is correctly connected to v FI00872
the ports.
v DEVTERM
2. Ensure that the device has power.
v MEDIA
If the attached tape device is owned by a Virtual I/O
Server partition refer to Troubleshooting the Virtual
I/O Server to determine the parts to replace.
Failing Item:
Failing Item:
63869302 63869302
v FI00871
v FI01112 Explanation: Tape device failure or media error
Failing Item:
63869304 63869304
v FCGATE
v FCIOA Explanation: Tape unit failure
63869899 63869899
Explanation: Problem analysis completed, the problem
has been corrected.
Response: This reference code is used for ending
Online Problem Analysis when no problem was found
or the problem was corrected.
63869900 63869900
Explanation: Licensed Internal Code for tape unit was
not upgraded
Response: The I/O processor loading of Licensed
Internal Code (LIC) to the programmable tape unit was
not completed.
The tape unit will continue to operate with the
previous LIC. You may do either of the following:
v Wait for next IPL when the system will attempt to
load the LIC for the tape drive again.
v Perform TUPIP04 to reset the IOP and the tape unit.
When the IOP is reset, if the device has the wrong
level of LIC, the IOP will attempt to load the new
LIC.
Failing Item:
v USER
Note: Use this table to handle reference codes that might be displayed during a
type D IPL to install the operating system. If you are not performing a type D IPL
of the operating system, consult any error logs found in the serviceable event view.
If you cannot locate an error log in the serviceable event view that corresponds
with the failure, run a verification test for the tape unit.
1. Verify that the device has power.
2. Check the device for any error indications. Refer to the device service
information to resolve any error indications.
3. Clean the recording head in the tape device.
4. Attempt the failing operation again. Does the operation complete successfully?
Yes: You have corrected the problem. This ends the procedure.
No: Look at the 8 rightmost characters of the Data display for Function 11,
which represent the reference code. Find the reference code in the following
list.
v FI00872 v FI00871
v DEVTERM v FI01112
v SASCABL
63879101 63879101
Explanation: Fibre Channel interface error detected 63879200 63879200
Response: If the attached device is an external device, Explanation: Tape unit is not responding
do the following before exchanging any parts: Response: If the attached device is an external device,
1. Ensure that the Fibre Channel cable is correctly do the following before exchanging any parts:
connected to the ports. 1. Ensure that the device is powered on.
2. Clean the Fibre Channel connectors. 2. Ensure that the signal cable is seated correctly, and
3. If there is a switch or hub attached, verify that it is that there are no bent or damaged pins on the cable.
operational. 3. For a SCSI attached device ensure that a
4. If there is a gateway device attached, refer to the terminating plug is attached to the device end of
gateway device service documentation for the SCSI cable.
additional problem analysis procedures.
5. refer to the tape device service documentation for If the attached tape device is owned by a Virtual I/O
additional problem analysis procedures. Server partition refer to Troubleshooting the Virtual
I/O Server to determine the parts to replace.
If the attached tape device is owned by a Virtual I/O Failing Item:
Server partition refer to Troubleshooting the Virtual
v FI00871
I/O Server to determine the parts to replace.
v FI01112
Failing Item:
v FI00872
v FCIOA
v DEVTERM
v FCDEV
v FCCABLE
63879201 63879201
Explanation: Tape unit command timeout
63879102 63879102
Response: If the attached device is an external device,
Explanation: Gateway device detected a SCSI interface
do the following before exchanging any parts:
error
1. Ensure that the device is powered on.
Response: Use the gateway device service
2. If an interposer is required, make sure that it is
documentation to analyze the problem.
connected between the I/O processor and the SCSI
Failing Item: cable.
v FI00871 3. Ensure that the signal cable is seated correctly, and
v FCGATE that there are no bent or damaged pins on the SCSI
cable.
v FI00872
4. Ensure that a terminating plug is attached to the
v DEVTERM
device end of the SCSI cable.
5. If the attached tape device is owned by a Virtual
63879103 63879103 I/O Server partition it may be necessary to reset the
Explanation: Interface error detected by system or by virtual IOP to recover from the error.
tape unit Failing Item:
Response: If the attached device is an external tape v FI00871
device, do the following before exchanging any parts: v FI01112
1. Ensure that the SAS cable is correctly connected to v FI00872
the ports.
v DEVTERM
2. Ensure that the device has power.
v MEDIA
If the attached tape device is owned by a Virtual I/O
Server partition refer to Troubleshooting the Virtual
I/O Server to determine the parts to replace.
Failing Item:
Failing Item:
63879302 63879302
v FI00871
v FI01112 Explanation: Tape device failure or media error
Failing Item:
63879304 63879304
v FCGATE
v FCIOA Explanation: Tape unit failure
63879899 63879899
Explanation: Problem analysis completed, the problem
has been corrected.
Response: This reference code is used for ending
Online Problem Analysis when no problem was found
or the problem was corrected.
63879900 63879900
Explanation: Licensed Internal Code for tape unit was
not upgraded
Response: The I/O processor loading of Licensed
Internal Code (LIC) to the programmable tape unit was
not completed.
The tape unit will continue to operate with the
previous LIC. You may do either of the following:
v Wait for next IPL when the system will attempt to
load the LIC for the tape drive again.
v Perform TUPIP04 to reset the IOP and the tape unit.
When the IOP is reset, if the device has the wrong
level of LIC, the IOP will attempt to load the new
LIC.
Failing Item:
v USER
Note: Use this table to handle reference codes that might be displayed during a
type D IPL to install the operating system. If you are not performing a type D IPL
of the operating system, consult any error logs found in the serviceable event view.
If you cannot locate an error log in the serviceable event view that corresponds
with the failure, run a verification test for the tape unit.
1. Verify that the device has power.
2. Check the device for any error indications. Refer to the device service
information to resolve any error indications.
3. Clean the recording head in the tape device.
4. Attempt the failing operation again. Does the operation complete successfully?
Yes: You have corrected the problem. This ends the procedure.
No: Look at the 8 rightmost characters of the Data display for Function 11,
which represent the reference code. Find the reference code in the following
list.
v FI00872 v FI00871
v DEVTERM v FI01112
v SASCABL
63A09101 63A09101
Explanation: Fibre Channel interface error detected 63A09200 63A09200
Response: If the attached device is an external device, Explanation: Tape unit is not responding
do the following before exchanging any parts: Response: If the attached device is an external device,
1. Ensure that the Fibre Channel cable is correctly do the following before exchanging any parts:
connected to the ports. 1. Ensure that the device is powered on.
2. Clean the Fibre Channel connectors. 2. Ensure that the signal cable is seated correctly, and
3. If there is a switch or hub attached, verify that it is that there are no bent or damaged pins on the cable.
operational. 3. For a SCSI attached device ensure that a
4. If there is a gateway device attached, refer to the terminating plug is attached to the device end of
gateway device service documentation for the SCSI cable.
additional problem analysis procedures.
5. refer to the tape device service documentation for If the attached tape device is owned by a Virtual I/O
additional problem analysis procedures. Server partition refer to Troubleshooting the Virtual
I/O Server to determine the parts to replace.
If the attached tape device is owned by a Virtual I/O Failing Item:
Server partition refer to Troubleshooting the Virtual
v FI00871
I/O Server to determine the parts to replace.
v FI01112
Failing Item:
v FI00872
v FCIOA
v DEVTERM
v FCDEV
v FCCABLE
63A09201 63A09201
Explanation: Tape unit command timeout
63A09102 63A09102
Response: If the attached device is an external device,
Explanation: Gateway device detected a SCSI interface
do the following before exchanging any parts:
error
1. Ensure that the device is powered on.
Response: Use the gateway device service
2. If an interposer is required, make sure that it is
documentation to analyze the problem.
connected between the I/O processor and the SCSI
Failing Item: cable.
v FI00871 3. Ensure that the signal cable is seated correctly, and
v FCGATE that there are no bent or damaged pins on the SCSI
cable.
v FI00872
4. Ensure that a terminating plug is attached to the
v DEVTERM
device end of the SCSI cable.
5. If the attached tape device is owned by a Virtual
63A09103 63A09103 I/O Server partition it may be necessary to reset the
Explanation: Interface error detected by system or by virtual IOP to recover from the error.
tape unit Failing Item:
Response: If the attached device is an external tape v FI00871
device, do the following before exchanging any parts: v FI01112
1. Ensure that the SAS cable is correctly connected to v FI00872
the ports.
v DEVTERM
2. Ensure that the device has power.
v MEDIA
If the attached tape device is owned by a Virtual I/O
Server partition refer to Troubleshooting the Virtual
I/O Server to determine the parts to replace.
Failing Item:
Failing Item:
63A09302 63A09302
v FI00871
v FI01112 Explanation: Tape device failure or media error
Failing Item:
63A09304 63A09304
v FCGATE
v FCIOA Explanation: Tape unit failure
63A09899 63A09899
Explanation: Problem analysis completed, the problem
has been corrected.
Response: This reference code is used for ending
Online Problem Analysis when no problem was found
or the problem was corrected.
63A09900 63A09900
Explanation: Licensed Internal Code for tape unit was
not upgraded
Response: The I/O processor loading of Licensed
Internal Code (LIC) to the programmable tape unit was
not completed.
The tape unit will continue to operate with the
previous LIC. You may do either of the following:
v Wait for next IPL when the system will attempt to
load the LIC for the tape drive again.
v Perform TUPIP04 to reset the IOP and the tape unit.
When the IOP is reset, if the device has the wrong
level of LIC, the IOP will attempt to load the new
LIC.
Failing Item:
v USER
Note: Use this table to handle reference codes that might be displayed during a
type D IPL to install the operating system. If you are not performing a type D IPL
of the operating system, consult any error logs found in the serviceable event view.
If you cannot locate an error log in the serviceable event view that corresponds
with the failure, run a verification test for the tape unit.
1. Verify that the device has power.
2. Check the device for any error indications. Refer to the device service
information to resolve any error indications.
3. Clean the recording head in the tape device.
4. Attempt the failing operation again. Does the operation complete successfully?
Yes: You have corrected the problem. This ends the procedure.
No: Look at the 8 rightmost characters of the Data display for Function 11,
which represent the reference code. Find the reference code in the following
list.
v FI00872 v FI00871
v DEVTERM v FI01112
v SASCABL
63A19101 63A19101
Explanation: Fibre Channel interface error detected 63A19200 63A19200
Response: If the attached device is an external device, Explanation: Tape unit is not responding
do the following before exchanging any parts: Response: If the attached device is an external device,
1. Ensure that the Fibre Channel cable is correctly do the following before exchanging any parts:
connected to the ports. 1. Ensure that the device is powered on.
2. Clean the Fibre Channel connectors. 2. Ensure that the signal cable is seated correctly, and
3. If there is a switch or hub attached, verify that it is that there are no bent or damaged pins on the cable.
operational. 3. For a SCSI attached device ensure that a
4. If there is a gateway device attached, refer to the terminating plug is attached to the device end of
gateway device service documentation for the SCSI cable.
additional problem analysis procedures.
5. refer to the tape device service documentation for If the attached tape device is owned by a Virtual I/O
additional problem analysis procedures. Server partition refer to Troubleshooting the Virtual
I/O Server to determine the parts to replace.
If the attached tape device is owned by a Virtual I/O Failing Item:
Server partition refer to Troubleshooting the Virtual
v FI00871
I/O Server to determine the parts to replace.
v FI01112
Failing Item:
v FI00872
v FCIOA
v DEVTERM
v FCDEV
v FCCABLE
63A19201 63A19201
Explanation: Tape unit command timeout
63A19102 63A19102
Response: If the attached device is an external device,
Explanation: Gateway device detected a SCSI interface
do the following before exchanging any parts:
error
1. Ensure that the device is powered on.
Response: Use the gateway device service
2. If an interposer is required, make sure that it is
documentation to analyze the problem.
connected between the I/O processor and the SCSI
Failing Item: cable.
v FI00871 3. Ensure that the signal cable is seated correctly, and
v FCGATE that there are no bent or damaged pins on the SCSI
cable.
v FI00872
4. Ensure that a terminating plug is attached to the
v DEVTERM
device end of the SCSI cable.
5. If the attached tape device is owned by a Virtual
63A19103 63A19103 I/O Server partition it may be necessary to reset the
Explanation: Interface error detected by system or by virtual IOP to recover from the error.
tape unit Failing Item:
Response: If the attached device is an external tape v FI00871
device, do the following before exchanging any parts: v FI01112
1. Ensure that the SAS cable is correctly connected to v FI00872
the ports.
v DEVTERM
2. Ensure that the device has power.
v MEDIA
If the attached tape device is owned by a Virtual I/O
Server partition refer to Troubleshooting the Virtual
I/O Server to determine the parts to replace.
Failing Item:
Failing Item:
63A19302 63A19302
v FI00871
v FI01112 Explanation: Tape device failure or media error
Failing Item:
63A19304 63A19304
v FCGATE
v FCIOA Explanation: Tape unit failure
63A19899 63A19899
Explanation: Problem analysis completed, the problem
has been corrected.
Response: This reference code is used for ending
Online Problem Analysis when no problem was found
or the problem was corrected.
63A19900 63A19900
Explanation: Licensed Internal Code for tape unit was
not upgraded
Response: The I/O processor loading of Licensed
Internal Code (LIC) to the programmable tape unit was
not completed.
The tape unit will continue to operate with the
previous LIC. You may do either of the following:
v Wait for next IPL when the system will attempt to
load the LIC for the tape drive again.
v Perform TUPIP04 to reset the IOP and the tape unit.
When the IOP is reset, if the device has the wrong
level of LIC, the IOP will attempt to load the new
LIC.
Failing Item:
v USER
66073010 66073010
66073110 66073110
Explanation: Disk device returned wrong response to
IOA Explanation: Disk bus interface error occurred
Explanation: A device replacement has occurred Explanation: Device or IOA Licensed Internal Code
Response: No action required. This reference code is Response: The device does not support a needed
logged for information only. attribute and is running with degraded performance.
Contact your next level of support.
Explanation: Disk media format not valid Response: If this event appears in a serviceable event
view, work with the failing item list found there. If this
Failing Item: event does not appear in a serviceable event view, no
v DISKDRV service action is required.
Failing Item:
6607FFF4 6607FFF4 v DISKDRV
Explanation: Disk device problem
Failing Item: 6607FFFA 6607FFFA
6607FFFB 6607FFFB
Explanation: SCSI bus reset occurred
Response: No action required. This reference code is
logged for information only.
6607FFFE 6607FFFE
Explanation: Temporary disk bus error
Response: If this event appears in a serviceable event
view, work with the failing item list found there. If this
event does not appear in a serviceable event view, no
service action is required.
Failing Item:
v DISKDRV
v STORIOA
v FI01106
v FI01140
67133010 67133010
67133110 67133110
Explanation: Disk device returned wrong response to
IOA Explanation: Disk bus interface error occurred
Explanation: A device replacement has occurred Explanation: Device or IOA Licensed Internal Code
Response: No action required. This reference code is Response: The device does not support a needed
logged for information only. attribute and is running with degraded performance.
Contact your next level of support.
Explanation: Disk media format not valid Response: If this event appears in a serviceable event
view, work with the failing item list found there. If this
Failing Item: event does not appear in a serviceable event view, no
v DISKDRV service action is required.
Failing Item:
6713FFF4 6713FFF4 v DISKDRV
Explanation: Disk device problem
Failing Item: 6713FFFA 6713FFFA
6713FFFB 6713FFFB
Explanation: SCSI bus reset occurred
Response: No action required. This reference code is
logged for information only.
6713FFFE 6713FFFE
Explanation: Temporary disk bus error
Response: If this event appears in a serviceable event
view, work with the failing item list found there. If this
event does not appear in a serviceable event view, no
service action is required.
Failing Item:
v DISKDRV
v STORIOA
v FI01106
v FI01140
67143010 67143010
67143110 67143110
Explanation: Disk device returned wrong response to
IOA Explanation: Disk bus interface error occurred
Explanation: A device replacement has occurred Explanation: Device or IOA Licensed Internal Code
Response: No action required. This reference code is Response: The device does not support a needed
logged for information only. attribute and is running with degraded performance.
Contact your next level of support.
Explanation: Disk media format not valid Response: If this event appears in a serviceable event
view, work with the failing item list found there. If this
Failing Item: event does not appear in a serviceable event view, no
v DISKDRV service action is required.
Failing Item:
6714FFF4 6714FFF4 v DISKDRV
Explanation: Disk device problem
Failing Item: 6714FFFA 6714FFFA
6714FFFB 6714FFFB
Explanation: SCSI bus reset occurred
Response: No action required. This reference code is
logged for information only.
6714FFFE 6714FFFE
Explanation: Temporary disk bus error
Response: If this event appears in a serviceable event
view, work with the failing item list found there. If this
event does not appear in a serviceable event view, no
service action is required.
Failing Item:
v DISKDRV
v STORIOA
v FI01106
v FI01140
67173010 67173010
67173110 67173110
Explanation: Disk device returned wrong response to
IOA Explanation: Disk bus interface error occurred
Explanation: A device replacement has occurred Explanation: Device or IOA Licensed Internal Code
Response: No action required. This reference code is Response: The device does not support a needed
logged for information only. attribute and is running with degraded performance.
Contact your next level of support.
Explanation: Disk media format not valid Response: If this event appears in a serviceable event
view, work with the failing item list found there. If this
Failing Item: event does not appear in a serviceable event view, no
v DISKDRV service action is required.
Failing Item:
6717FFF4 6717FFF4 v DISKDRV
Explanation: Disk device problem
Failing Item: 6717FFFA 6717FFFA
6717FFFB 6717FFFB
Explanation: SCSI bus reset occurred
Response: No action required. This reference code is
logged for information only.
6717FFFE 6717FFFE
Explanation: Temporary disk bus error
Response: If this event appears in a serviceable event
view, work with the failing item list found there. If this
event does not appear in a serviceable event view, no
service action is required.
Failing Item:
v DISKDRV
v STORIOA
v FI01106
v FI01140
67183010 67183010
67183110 67183110
Explanation: Disk device returned wrong response to
IOA Explanation: Disk bus interface error occurred
Explanation: A device replacement has occurred Explanation: Device or IOA Licensed Internal Code
Response: No action required. This reference code is Response: The device does not support a needed
logged for information only. attribute and is running with degraded performance.
Contact your next level of support.
Explanation: Disk media format not valid Response: If this event appears in a serviceable event
view, work with the failing item list found there. If this
Failing Item: event does not appear in a serviceable event view, no
v DISKDRV service action is required.
Failing Item:
6718FFF4 6718FFF4 v DISKDRV
Explanation: Disk device problem
Failing Item: 6718FFFA 6718FFFA
6718FFFB 6718FFFB
Explanation: SCSI bus reset occurred
Response: No action required. This reference code is
logged for information only.
6718FFFE 6718FFFE
Explanation: Temporary disk bus error
Response: If this event appears in a serviceable event
view, work with the failing item list found there. If this
event does not appear in a serviceable event view, no
service action is required.
Failing Item:
v DISKDRV
v STORIOA
v FI01106
v FI01140
67193010 67193010
67193110 67193110
Explanation: Disk device returned wrong response to
IOA Explanation: Disk bus interface error occurred
Explanation: A device replacement has occurred Explanation: Device or IOA Licensed Internal Code
Response: No action required. This reference code is Response: The device does not support a needed
logged for information only. attribute and is running with degraded performance.
Contact your next level of support.
Explanation: Disk media format not valid Response: If this event appears in a serviceable event
view, work with the failing item list found there. If this
Failing Item: event does not appear in a serviceable event view, no
v DISKDRV service action is required.
Failing Item:
6719FFF4 6719FFF4 v DISKDRV
Explanation: Disk device problem
Failing Item: 6719FFFA 6719FFFA
6719FFFB 6719FFFB
Explanation: SCSI bus reset occurred
Response: No action required. This reference code is
logged for information only.
6719FFFE 6719FFFE
Explanation: Temporary disk bus error
Response: If this event appears in a serviceable event
view, work with the failing item list found there. If this
event does not appear in a serviceable event view, no
service action is required.
Failing Item:
v DISKDRV
v STORIOA
v FI01106
v FI01140
Explanation: Synchronous-data-link-control
6A590C90 6A590C90
send-receive test failed
Explanation: Communications adapter card X.21 test
Failing Item:
failed
v FI00719
Failing Item:
v FI00718
v FI00719
v FI00718
6A590C50 6A590C50
Explanation: Binary synchronous control send-receive
6A590CA1 6A590CA1
test failed
Explanation: Communications adapter card test failed
Failing Item:
v FI00719 Failing Item:
v FI00718 v FI00719
v FI00718
6A590C53 6A590C53
6A590CC0 6A590CC0
Explanation: Binary synchronous control send-receive
test failed Explanation: Communications adapter card test failed
Failing Item: Failing Item:
v FI00719 v FI00719
v FI00718 v FI00718
6A59FFFF 6A59FFFF
6A590C70 6A590C70
Explanation: User suspected problem
Explanation: Communications adapter card test failed
Failing Item:
Failing Item:
v USER
v FI00719
v FI00718
6A590C80 6A590C80
Explanation: Communications adapter card test failed
Failing Item:
v FI00719
v FI00718
6B259500 6B259500
Explanation: Internal program error in driver code.
Failing Item:
v PTFSRCH
6B259903 6B259903
Explanation: Tape device information was logged.
Informational event, no service required.
Note: Use this table to handle reference codes that might be displayed during a
type D IPL to install the operating system. If you are not performing a type D IPL
of the operating system, consult any error logs found in the serviceable event view.
If you cannot locate an error log in the serviceable event view that corresponds
with the failure, run a verification test for the tape unit.
1. Verify that the device has power.
2. Check the device for any error indications. Refer to the device service
information to resolve any error indications.
3. Clean the recording head in the tape device.
4. Attempt the failing operation again. Does the operation complete successfully?
Yes: You have corrected the problem. This ends the procedure.
No: Look at the 8 rightmost characters of the Data display for Function 11,
which represent the reference code. Find the reference code in the following
list.
v FI00872 v FI00871
v DEVTERM v FI01112
v SASCABL
72079101 72079101
Explanation: Fibre Channel interface error detected 72079200 72079200
Response: If the attached device is an external device, Explanation: Tape unit is not responding
do the following before exchanging any parts: Response: If the attached device is an external device,
1. Ensure that the Fibre Channel cable is correctly do the following before exchanging any parts:
connected to the ports. 1. Ensure that the device is powered on.
2. Clean the Fibre Channel connectors. 2. Ensure that the signal cable is seated correctly, and
3. If there is a switch or hub attached, verify that it is that there are no bent or damaged pins on the cable.
operational. 3. For a SCSI attached device ensure that a
4. If there is a gateway device attached, refer to the terminating plug is attached to the device end of
gateway device service documentation for the SCSI cable.
additional problem analysis procedures.
5. refer to the tape device service documentation for If the attached tape device is owned by a Virtual I/O
additional problem analysis procedures. Server partition refer to Troubleshooting the Virtual
I/O Server to determine the parts to replace.
If the attached tape device is owned by a Virtual I/O Failing Item:
Server partition refer to Troubleshooting the Virtual
v FI00871
I/O Server to determine the parts to replace.
v FI01112
Failing Item:
v FI00872
v FCIOA
v DEVTERM
v FCDEV
v FCCABLE
72079201 72079201
Explanation: Tape unit command timeout
72079102 72079102
Response: If the attached device is an external device,
Explanation: Gateway device detected a SCSI interface
do the following before exchanging any parts:
error
1. Ensure that the device is powered on.
Response: Use the gateway device service
2. If an interposer is required, make sure that it is
documentation to analyze the problem.
connected between the I/O processor and the SCSI
Failing Item: cable.
v FI00871 3. Ensure that the signal cable is seated correctly, and
v FCGATE that there are no bent or damaged pins on the SCSI
cable.
v FI00872
4. Ensure that a terminating plug is attached to the
v DEVTERM
device end of the SCSI cable.
5. If the attached tape device is owned by a Virtual
72079103 72079103 I/O Server partition it may be necessary to reset the
Explanation: Interface error detected by system or by virtual IOP to recover from the error.
tape unit Failing Item:
Response: If the attached device is an external tape v FI00871
device, do the following before exchanging any parts: v FI01112
1. Ensure that the SAS cable is correctly connected to v FI00872
the ports.
v DEVTERM
2. Ensure that the device has power.
v MEDIA
If the attached tape device is owned by a Virtual I/O
Server partition refer to Troubleshooting the Virtual
I/O Server to determine the parts to replace.
Failing Item:
Failing Item:
72079302 72079302
v FI00871
v FI01112 Explanation: Tape device failure or media error
Failing Item:
72079304 72079304
v FCGATE
v FCIOA Explanation: Tape unit failure
72079899 72079899
Explanation: Problem analysis completed, the problem
has been corrected.
Response: This reference code is used for ending
Online Problem Analysis when no problem was found
or the problem was corrected.
72079900 72079900
Explanation: Licensed Internal Code for tape unit was
not upgraded
Response: The I/O processor loading of Licensed
Internal Code (LIC) to the programmable tape unit was
not completed.
The tape unit will continue to operate with the
previous LIC. You may do either of the following:
v Wait for next IPL when the system will attempt to
load the LIC for the tape drive again.
v Perform TUPIP04 to reset the IOP and the tape unit.
When the IOP is reset, if the device has the wrong
level of LIC, the IOP will attempt to load the new
LIC.
Failing Item:
v USER
A181D000 A181D000
Explanation: The hypervisor did not respond to a
ROLE or FAILOVER message. If the system hangs on
this progress code, perform isolation procedure
FSPSPC1.
A181D001 A181D001
Explanation: The hypervisor did not post an Xdown
interrupt when a reset/reload occurred. If the system
hangs on this progress code, perform isolation
procedure FSPSPC1.
A1A3C100 A1A3C100
Explanation: Invalid operational mode for remote
power on (wake onLAN)
Response: Check the service processor settings for
remote power on. If the system hangs on this progress
code, perform isolation procedure FSPSPC1.
Failing Item:
A2002426 A2002426
v SLOTUSE
Explanation: A problem occurred during the IPL of a
partition.
A2002300 A2002300
Response: The partition ID is in extended word one
Explanation: A problem occurred during the IPL of a
as LP=xxx in decimal format. The platform LIC for this
partition.
partition attempted an operation. There was a failure.
Response: The partition ID is in extended word one Contact your next level of support.
as LP=xxx in decimal format. A slot that was needed
Failing Item:
for the partition was unavailable. See the Symbolic FRU
SLOTUSE for more information on the cause of this v NEXTLVL
error.
Failing Item: A2002475 A2002475
v SLOTUSE Explanation: A problem occurred during the IPL of a
partition.
A2002310 A2002310 Response: The partition ID is in extended word one
as LP=xxx in decimal format. A slot that was needed
Explanation: A problem occurred during the IPL of a
for the partition was either empty or the device in the
partition.
slot has failed. See the Symbolic FRU SLOTUSE for
Response: The partition ID is in extended word one more information on the cause of this error.
as LP=xxx in decimal format. The platform LIC for this
If you have a RAID enablement card (CCIN 5709) on
partition attempted an operation. There was a failure.
your system, it will disable an embedded SCSI adapter.
Contact your next level of support.
If that embedded slot is called out in the error, you can
Failing Item: safely ignore this error.
v NEXTLVL Failing Item:
v SLOTUSE
A2002320 A2002320
Explanation: A problem occurred during the IPL of a A2002477 A2002477
partition.
Explanation: A problem occurred during the IPL of a
Response: The partition ID is in extended word one partition.
as LP=xxx in decimal format. The platform LIC for this
Response: No service action required.
partition attempted an operation. There was a failure.
Contact your next level of support.
A2002479 A2002479
Failing Item:
v NEXTLVL Explanation: A problem occurred during the IPL of a
partition.
A2003123 A2003123
A2D03001 A2D03001
Explanation: System log entry only, no service action
required Explanation: User-initiated RSCDUMP of RPA
partition's PFW content.
A2009010 A2009010
Explanation: A problem occurred during the IPL of a
partition.
A2009020 A2009020
Explanation: A problem occurred during the IPL of a
partition.
A2009030 A2009030
Explanation: A problem occurred during the IPL of a
partition.
A200B07B A200B07B
Explanation: System log entry only, no service action
required
Response: No service action required.
A6xx0105 A6xx0105 Explanation: The system ASP has run out of disk
storage.
Explanation: More than one request to terminate the
system was issued Response: The out of storage condition in the system
ASP can be caused by an allocation failure in some
Failing Item: other system software. This could be a looping
v LICIP08 condition that continues to allocate storage. Contact
v AJDG301 your service representative for assistance with the Main
Storage Dump.
A6xx0106 A6xx0106
A6xx0231 A6xx0231
Explanation: Terminate Immediate data is not valid
v AJDG301
A6xx1104 A6xx1104
Explanation: Failure reading media or not install
A6xx1724 A6xx1724
media
Explanation: An attempt to create a segment failed
Response: Determine that correct install media is
loaded. If correct install media is installed, media could Response: The create could fail for two reasons:
be corrupt. Obtain another copy of the install media v A code problem. Perform the procedure indicated in
and re-attempt the install. If the install still fails, contact the failing item list.
your service representative.
v No free auxiliary storage on the system. Add
additional DASD if the create failed because no
A6xx1201 A6xx1201 auxiliary storage was available.
Explanation: Critical database segment could not be Failing Item:
created v LICIP08
Failing Item: v AJDG301
v LICIP08
v AJDG301 A6xx1730 A6xx1730
Explanation: An IPL is needed to restore system
A6xx1204 A6xx1204 performance
Explanation: Error in constraint enforcement Response: Licensed Internal Code has detected a
condition that is impacting system performance. System
Failing Item:
operation can continue, but system performance may
v LICIP08 be noticeably reduced until the next IPL.
v AJDG301
Look at the Product Activity Log entry, and find the
value at offset x'000180'. If the value equals x'00000122',
A6xx1210 A6xx1210 the error was caused by too much processor memory
being installed.
Explanation: Object not found in the in-use table
For more information, contact IBM Service Support.
Failing Item:
v LICIP08 Failing Item:
v AJDG301 v UPLF1
Explanation: Error in critical code sequence Explanation: LPAR service function directed a Main
Storage Dump.
Failing Item:
Response: Copy the current main storage dump to
v LICIP08
media. For more information on how to copy a Main
v AJDG301 Storage Dump, refer to Copying a main storage dump.
Failing Item:
A6xx1219 A6xx1219
v AJDG301
Explanation: A back leveled driver has been detected
Failing Item: A6xx41FC A6xx41FC
v LICIP08 Explanation: Installation of LIC failed
v AJDG301
Response: Words 12 and 13 of this SRC contain
additional diagnostic information.
A6xx1604 A6xx1604
Install LIC using physical media.
Explanation: Not able to create APPN task
To determine what caused the failure, collect SRC
Response: An error occurred during task creation information and contact your next level of support.
which requires a power off of the system.
Failing Item:
Failing Item: v SVCDOCS
v LICIP08
For more information on how to perform a Main Explanation: Insufficient space in the ASP to store a
Storage Dump, refer to Copying a main storage dump. platform dump
Response: The platform produced dump data, and the
A6xx4402 A6xx4402 Main Storage Dump (MSD) Manager was configured to
automatically copy the dump to an Auxiliary Storage
Explanation: Missing DASD units. Pool (ASP), but there was not sufficient free space
available in the ASP. The dump will be lost if the
Response: Copy the current main storage dump to
system power is lost. Manually copy the current
media. Then exit the Main Storage Dump Manager.
platform dump from the platform by performing one of
For more information on how to perform a Main the following:
Storage Dump, refer to Copying a main storage dump. v Make room in the designated ASP and then use the
MSD Manager to copy the current platform dump to
A6xx4403 A6xx4403 ASP.
v Use the MSD Manager to delete other dump copies,
Explanation: Storage Management failed to reach full
then copy the current platform dump to ASP.
paging.
v Use the MSD Manager to copy the current platform
Response: Copy the current main storage dump to dump to a different ASP.
media.
v Use the MSD Manager to copy the current platform
For more information on how to perform a Main dump to media.
Storage Dump, refer to Copying a main storage dump.
A6xx4422 A6xx4422
A6xx4404 A6xx4404
Explanation: A platform dump is saved in MSD
Explanation: Auto copy failed or not attempted. Manager
Response: Copy the current main storage dump. If Response: The platform produced dump data. The
copying to system ASP, existing copies may need to be dump data was copied to the Main Storage Dump
deleted or renamed. Then exit the Main Storage Dump (MSD) Manager.
Manager.
Failing Item:
For more information on how to perform a Main v PLDUMP
Storage Dump, refer to Copying a main storage dump.
Contact your service provider. Response: Correct any Processor Capacity card or
SPCN failures.
Failing Item:
Failing Item:
v AJDG301
v CTLPNCD
A6xx4710 A6xx4710
A6xx4730 A6xx4730
Explanation: Processor On Demand error detected.
Explanation: Processor On Demand error detected.
Response: SPCN communication failure during
Processor On Demand. Response: Processor On Demand standby processors
are in use.
Look in the Product Activity Log for other SPCN errors
and perform the actions indicated for those errors. Contact your service provider.
v SPNLCRD v AJDG301
Explanation: Processor On Demand error detected. Explanation: Processor On Demand error detected.
Response: Correct any Processor Capacity card or Response: The Processor On Demand Trial Activation
SPCN failures. period is not valid. Contact your next level of support.
v CTLPNCD v AJDG301
Explanation: Incorrect Processor Capacity Card Explanation: Processor On Demand error detected.
installed. Response: Contact your service provider.
Response: The Processor Capacity Card is the failing Failing Item:
v AJDG301
v AJDG301
A6xx4740 A6xx4740
v FI00380
Explanation: Processor On Demand error detected.
Response: The Processor On Demand Activation code A6xx5003 A6xx5003
just entered is not valid.
Explanation: Service program failed
Contact your next level of support.
Response: The ASCII system console failed to
Failing Item: respond.
v AJDG301
Failing Item:
v FI00320
A6xx4741 A6xx4741
v FI00602
Explanation: Processor On Demand error detected. v USER
Response: An invalid Processor On Demand v AJDG301
Activation code has been entered more than 5 v FI00380
consecutive times. Contact your service provider.
Failing Item: A6xx5004 A6xx5004
v AJDG301
Explanation: DST console failed to respond
Response: The system console failed to respond.
A6xx4745 A6xx4745
Failing Item:
Explanation: Processor Capacity card replaced on
activated POD system. v RTRIP02
v FI00320
Response: Contact IBM Support to order a
replacement Processor On Demand activation code. v FI00602
v USER
A6xx4747 A6xx4747 v AJDG301
v FI00380
Explanation: 1 hour left in POD 14 day Trial
Activation Period.
A6xx5005 A6xx5005
Response: If a new activation code was purchased, it
should be entered now. Otherwise, the system will Explanation: Service program failed
revert back to its previous activation state at the end of
the Trial Activation Period. Response: The workstation adapter system console
failed to respond.
v AJDG301
A6xx5090 A6xx5090
v FI00380
Explanation: System startup failed in unattended IPL
mode
A6xx5008 A6xx5008
Response: Perform the following:
Explanation: DST console failed to respond
v If reference code A6xx5090 is displayed on the
Response: control panel for more than 10 minutes, perform the
procedure indicated in the failing item list.
Failing Item:
v For reference code B6xx5090, perform the procedure
v OPCIP03 indicated in the failing item list.
v FI00719
Failing Item:
v LICIP11
A6xx5010 A6xx5010
v FI00580
Explanation: IPL service function ended abnormally v FI00500
Failing Item: v FI00301
v LICIP04 v FI00021
v AJDG301 v FI00065
v AJDG301
A6xx5014 A6xx5014
Explanation: DST status. The Storage Management A6xx5092 A6xx5092
Dual Path Information Screen option to dump data to a Explanation: System is in DASD migration mode
PAL has completed successfully.
Response: Install Licensed Internal Code and Upgrade
Load Source was specified but the key is not in the
A6xx5015 A6xx5015 manual position. Change the key position to manual
Explanation: DST error. An error has occurred and perform a system IPL.
gathering data for the Storage Management Dual Path
Information Screen option to dump data to a PAL. A6xx5094 A6xx5094
Contact your next level of support or hardware service
provider. Explanation: IASP detected a failure during the vary
on operation
Failing Item:
v NEXTLVL Failing Item:
v LICIP12
A6xx5082 A6xx5082
A6xx50FF A6xx50FF
Explanation: DST lost contact with the console
Explanation: DST unrecoverable program error
Response: A service program lost contact with the
system console. Failing Item:
Failing Item: v LICIP03
v RTRIP03 v AJDG301
v AJDG301 v FI00380
v USER
A6xx5120 A6xx5120
A6xx5083 A6xx5083 Explanation: System LIC detected a program
exception
Explanation: IPL service function ended abnormally
Response: System LIC detected a programming
Response: A service program lost contact with the problem. If performance or other system degradation is
system console. occurring, the system may be operating with reduced
Failing Item: resources.
v TWSIP01 Check the Product activity log for related entries. If this
v AJDG301 reference code is logged with an error class of
Informational, then no action is required.
v USER
Response: System LIC detected an IOP programming Explanation: I/O processor failure
problem for which an IOP dump may have been Failing Item:
initiated.
v FI01112
Failing Item: v FI01107
v LICIP01
v FI00130 A6xx512D A6xx512D
v AJDG301
Explanation: An IOP dump was initiated
v FI00131
Response: Copy the IOP dump entry and any related
entries from the Product Activity Log to suitable media,
A6xx5123 A6xx5123 and give to an IBM service representative.
Explanation: LIC program exception occurred
Response: System LIC detected an interface problem A6xx512E A6xx512E
with the IOP or an IOP programming problem for Explanation: LIC program exception occurred
which an IOP and main storage dump may have been
initiated. Response: The system was in a D IPL mode when the
problem was detected. A main storage dump was not
Failing Item: taken.
v LICIP01
Failing Item:
v FI00130
v LICIP01
v AJDG301
v AJDG301
v FI00131
v FI00130
A6xx5126 A6xx5126
A6xx5192 A6xx5192
Explanation: Addressed device failed to respond to
Explanation: Insufficient entitled memory for the I/O
selection
configuration
Failing Item:
Response: Use the hardware management console to
v DISKDRV increase the entitled memory capacity of the partition
v STORIOA and restart the I/O adapter. To restart a storage I/O
v DISKTRY adapter, use Hardware Service Manager to re-IPL the
virtual I/O processor that is associated with this I/O
A6xx5194 A6xx5194
A6xx5275 A6xx5275
Explanation: Insufficient entitled memory for the I/O
configuration Explanation: The system issued a reset/reload to the
IOP.
Response: Use the hardware management console to
increase the entitled memory capacity of the partition Response: System Licensed Internal Code detected
and restart the partition. that an IOP Reset/Reload has occurred, and that the
IOP successfully recovered.
Failing Item:
Users who were signed on to a Workstation device
v SVCDOCS
under the IOP will need to sign back on. Any
LAN/WAN communications lines under the IOP will
A6xx5206 A6xx5206 need to be restarted. Tape/Optical devices under the
IOP may need to be varied back on.
Explanation: System LIC detected a missing IOP LIC
code load To determine the cause of the IOP Reset/Reload, check
the Product Activity Log for additional entries logged
Response: System LIC detected a missing IOP LIC with the same System Log ID, and perform any actions
code load during IPL of the IOP. This indicates that indicated for those errors.
either the IOP code load is not installed on the system
Load Source device or that system LIC was unable to
successfully read that load from the Load Source A6xx5276 A6xx5276
device.
Explanation: IOP Reset was issued
Failing Item:
Response: LIC has detected a problem with the
v LICIP01 Service Processor IOP and has reset it but has not
v USER initiated reload of the Service Processor.
If the Load Source is mirrored, some system operations
A6xx5209 A6xx5209 may be able to continue normally. However, some
system service operations have been suspended and the
Explanation: System LIC detected an IOP timeout system should be scheduled for power down as soon
during IOP IPL as possible.
Response: Verify that all IOP cable connections are Failing Item:
secure, and check tape and other non-disk devices and
media to verify that they are in a ready state. v RTRIP08
v AJGLD01
Failing Item:
v AJDG301
v LICIP01
v FI00021
v USER
v FI00130
v AJDG301
Explanation: LIC program exception occurred Response: Check the primary partition Product
Activity Log for system memory entries from
Response: LPAR configuration data does not match approximately the same time. Perform the actions
current system configuration. The system will not IPL indicated for those entries.
past DST until the problem is corrected.
Following is a list of problems which may have caused A6xx5342 A6xx5342
this SRC to be reported:
Explanation: Secondary partition not running at
v Non-configured disk unit which was previously a
optimum.
load source on a partitioned system.
v Load Source configuration data does not match Response: Check the Primary partition's Product
partition for which it is being used. Activity Log for system processor entries from
approximately the same time. Perform the actions
v Load Source configuration data does not match
indicated for those entries.
system serial number for which it is being used.
v Load Source configuration data is newer than
primary partition configuration data. A6xx5343 A6xx5343
Failing Item:
A6xx6907 A6xx6907
v SIIOADP
Explanation: High Speed Link (HSL) I/O bridge
v OPT_CLN
failure
Response: LIC detected invalid data in the HSL I/O
A6xx6909 A6xx6909
bridge VPD. The bridge and HSL loop may not have
become operational. Explanation: High Speed Link (HSL) I/O bridge
failure
For this reference code the failing item list presented in
the Service Action Log (SAL), or serviceable event view Response: LIC detected invalid data in the I/O bus
you are working with, can be different from the failing VPD. The bus and resources associated with it may not
item list documented here. That is due to the be operational.
differences in system models and features installed.
For this reference code the failing item list presented in
If the Service Action Log (SAL) or serviceable event the Service Action Log (SAL), or serviceable event view
view on the hardware management console, is available you are working with, can be different from the failing
then use the failing item list presented there for item list documented here. That is due to the
servicing this reference code. differences in system models and features installed.
If a serviceable event view is not available then use the If the Service Action Log (SAL) or serviceable event
failing item list documented here. By following the viewer on the hardware management console is
procedures in the symbolic FRUs listed here you will available then use the failing item list presented there
isolate to the correct FRU list based on system model for servicing this reference code.
and features installed.
If a serviceable event view is not available then use the
NOTE: A fiber optic cleaning kit may be required for failing item list documented here. By following the
optical HSL connections. procedures in the symbolic FRUs listed here you will
isolate to the correct FRU list based on system model
Failing Item:
and features installed.
v SIIOADP
If the serviceable event view only indicated a frame or
v OPT_CLN
enclosure see the locations section for the frame or
enclosure type. The location of the HSL I/O Bridge will
A6xx6908 A6xx6908 be given in the locations tables.
Explanation: High Speed Link (HSL) I/O bridge NOTE: A fiber optic cleaning kit may be required for
failure optical HSL connections.
Response: LIC data in the I/O bus VPD could not be Failing Item:
accessed. The I/O Bus identified in the SRC may not v SIIOADP
have become operational.
v OPT_CLN
If there is a B6xx 6906 reference code, close this
problem in the serviceable event view you are working
A6xx690A A6xx690A
with and work the 6906 error.
Explanation: Associated adapter not found in this
For this reference code the failing item list presented in
partition
the Service Action Log (SAL), or serviceable event view
you are working with, can be different from the failing Failing Item:
item list documented here. That is due to the v LICIP16
differences in system models and features installed.
If the Service Action Log or serviceable event view on A6xx6910 A6xx6910
the hardware management console or service processor
is available then use the failing item list presented there Explanation: I/O processor failure
for servicing this reference code.
Response: An I/O processor timed out, returned bad
If a serviceable event view is not available then use the status, or is not following the system bus protocol.
failing item list documented here. By following the
Failing Item:
procedures in the symbolic FRUs listed here you will
isolate to the correct FRU list based on system model v LICIP07
and features installed. v FI00310
NOTE: A fiber optic cleaning kit may be required for v FI00318
optical HSL connections. v FI00065
v FI00130
A6xx6960 A6xx6960 See SLOTERR symbolic FRU for the list of messages
and a further description of the problem detected by
Explanation: Multi-adapter bridge card slot error, do Licensed Internal Code.
not use card slot
For this reference code the failing item list presented in
Response: Slot unavailable due to 64 bit card in the Service Action Log (SAL), or serviceable event view
adjacent slot. you are working with, can be different from the failing
One of the messages documented with the symbolic item list documented here. That is due to the
FRU will describe the problem. See SLOTERR symbolic differences in system models and features installed.
FRU for a list of messages and corrective actions. If the Service Action Log, or serviceable event view on
Failing Item: the hardware management console is available then use
the failing item list presented there for servicing this
v SLOTERR reference code.
If a serviceable event view is not available then use the
A6xx6961 A6xx6961 failing item list documented here. By following the
Explanation: Multi-adapter bridge card slot error, do procedures in the symbolic FRUs listed here you will
not use card slot isolate to the correct FRU list based on system model
and features installed.
Response: LED control failure, do not use slot.
Failing Item:
The card location is not available for use. The Failing
v SLOTERR
Item with the card slot error is in the Failing Item list
for this reference code. v MASBUS
The card location is not available for use. The Failing Failing Item:
Item with the card slot error is in the Failing Item list v MABRCFG
for this reference code.
See SLOTERR symbolic FRU for the list of messages A6xx6965 A6xx6965
and a further description of the problem detected by
Licensed Internal Code. Explanation: Multi-adapter bridge configuration
change or error
For this reference code the failing item list presented in
the Service Action Log (SAL), or serviceable event Response: Card type not supported in this slot.
viewer you are working with, can be different from the An I/O processor or I/O adapter card type is installed
failing item list documented here. That is due to the in the location indicated in word 7 of the SRC. The
differences in system models and features installed. card type is not supported in that slot under the
If the Service Action Log or serviceable event viewer on multi-adapter bridge. The card is unavailable.
the hardware management console is available then use See MABRCFG symbolic FRU for the list of messages, a
the failing item list presented there for servicing this further description of the problem detected by Licensed
reference code. Internal Code and the corrective action.
If serviceable event view is not available then use the Failing Item:
failing item list documented here. By following the
procedures in the symbolic FRUs listed here you will v MABRCFG
isolate to the correct FRU list based on system model
and features installed. A6xx6966 A6xx6966
Failing Item: Explanation: Multi-adapter bridge configuration
v SLOTERR change or error
v MASBUS Response: I/O processor removed from multi-adapter
bridge card slot.
A6xx6964 A6xx6964 On the previous IPL an I/O processor was in the card
Explanation: Multi-adapter bridge configuration location specified in word 7 of the SRC. The I/O
change or error processor was not detected on this IPL.
Response: One of several errors or configuration See MABRCFG symbolic FRU for the list of messages, a
problems has occurred under a Multi-adapter bridge. If further description of the problem detected by Licensed
you are using the Service Action Log (SAL), or the Internal Code and the corrective action.
serviceable event viewer on the hardware management Failing Item:
console or the service processor, then the correct FRU,
v MABRCFG
description and card position(s) will be listed. Use the
FRUs and descriptions in the serviceable event view
you are working with to determine the problem. A6xx6967 A6xx6967
If you do not have access to the Service Action Log, or Explanation: Multi-adapter bridge configuration
serviceable event view on the hardware management change or error
console or service processor, then word 4 of the SRC
Response: I/O adapter unavailable due to moved I/O
has more information. Examine the last 4 digits in word
processor card.
4 to determine the problem by comparing them to the
list below and using the FRU(s) listed here. The I/O adapter specified in word 7 of the SRC is not
1. xxxx2022 - IOP found in slots owned by a Linux available. On the previous IPL there was an I/O
partition. The Multi-adapter Bridge and PCI Bridge processor card the adapter was assigned to. The I/O
set that it controls are assigned to a Linux partition. processor was not detected on this IPL.
The IOP found in the SLOT indicated by the DSA in See MABRCFG symbolic FRU for the list of messages, a
word 7 will not be configured. further description of the problem detected by Licensed
2. xxxx2014 - I/O adapters were found under the Internal Code and the corrective action.
Multi-adapter Bridge but there is no IOP to support
them. The adapters cannot be used. Failing Item:
3. xxxx2015 - An card type was found that cannot be v MABRCFG
supported in the card position where it is located.
Failing Item: NOTE: This SRC can occur for the PCI bus resource on
a PCI bus in an I/O expansion unit when the unit is
v MABRCFG powered off for a concurrent maintenance action.
If the Service Action Log, or serviceable event view on
A6xx696A A6xx696A the hardware management console or service processor,
Explanation: Card slot test failed is available then use the failing item list presented there
for servicing this reference code.
Failing Item:
If a serviceable event view is not available then use the
v LICIP14
failing item list documented here.
v FI00131
NOTE: A fiber optic cleaning kit may be required for
v BACKPLN
optical HSL connections.
Failing Item:
A6xx696B A6xx696B
v SI_PHB
Explanation: Card slot could not be validated
v PRI_PCI
Response: This can be caused by "PCI error injection v MA_BRDG
policy" being set to "YES" and an I/O Processor being
v MABIP03
installed on the same Multi-adapter bridge domain as
the I/O Adapter. Do one of the following: v BRDGSET
v OPT_CLN
-- Using the hardware management console or a
customer PC with a Web browser access the Advanced
System Management Interface (ASMI) and disable PCI A6xx6971 A6xx6971
error injection policy.
Explanation: High Speed Link (HSL) resource failure
OR
Response: A failure occurred in a multi-adapter
-- Vary off the I/O Adapter. Using Hardware Service bridge or on the bus to the card location it controls.
If a serviceable event view is available, use the failing of or the removal of an I/O adapter.
item list presented there for servicing this reference
Failing Item:
code.
v MABRCFG
If a serviceable event view is not available, use the
failing item list documented here.
A6xx6975 A6xx6975
Failing Item:
Explanation: The system issued a reset/reload to the
v MABIP02
service processor.
v MA_BRDG
Response: Service processor error.
v MASBUS
v PIOCARD Failing Item:
v AJDGP01
A6xx6972 A6xx6972
A6xx6976 A6xx6976
Explanation: High Speed Link (HSL) resource failure
Explanation: Service processor failure.
Response: Multi-adapter Bridge (MaB) failure
detected. Response: For this reference code the failing item list
presented in the Service Action Log (SAL), or
For this reference code the failing item list presented in
serviceable event view you are working with, can be
the Service Action Log (SAL), or serviceable event
different from the failing item list documented here.
viewer you are working with, can be different from the
That is due to the differences in system models and
failing item list documented here. That is due to the
features installed.
differences in system models and features installed.
If the Service Action Log (SAL) or a serviceable event
If the Service Action Log (SAL) or serviceable event
viewer on the hardware management console is
viewer on the hardware management console is
available then use the failing item list presented there
available then use the failing item list presented there
for servicing this reference code.
for servicing this reference code.
If a serviceable event viewer is not available then use
If a serviceable event view is not available then use the
the failing item list documented here. By following the
failing item list documented here. By following the
procedures in the symbolic FRUs listed here you will
procedures in the symbolic FRUs listed here you will
isolate to the correct FRU list based on system model
isolate to the correct FRU list based on system model
and features installed.
and features installed.
Failing Item:
Failing Item:
v SVCPROC
v MA_BRDG
A6xx6980 A6xx6980
A6xx6973 A6xx6973
Explanation: Network Interface Controller / IO Hub
Explanation: High Speed Link (HSL) resource failure
failure.
Response: Multi-adapter Bridge has detected a
Response: For Power5 and newer servers, service this
problem in the card installed in the location specified in
error using the B7006980 service information.
word 7 of the SRC. Use the FRU list in the Service
Otherwise, continue with this information.
Action Log (SAL), or serviceable event view you are
working with. If you are working from this document's The FRU list displayed in the Service Action Log (SAL)
FRU list use the Symbolic FRU BRDGSET to determine or serviceable event view you are working with, may
the failing items. vary from the failing item list given in this document.
Use the FRU list in the serviceable event view if it is
Failing Item:
available to you.
v BRDGSET
NOTE: A fiber optic cleaning kit may be required for
v SIIOADP
optical HSL connections.
v MA_BRDG
Failing Item:
v SICNTRL
A6xx6974 A6xx6974
v OPT_CLN
Explanation: Multi-adapter bridge configuration
change or error
Response: PCI I/O processor rejected the assignment
This error can appear as a serviceable event when a NOTE: A fiber optic cleaning kit may be required for
tower, or I/O unit or another system in the loop did optical HSL connections.
not complete powering on before LIC on this system
Failing Item:
checked this loop for errors. Search the Product
Activity Log (PAL) for the last B6xx 6985 SRC logged v SIRSTAT
for this loop and use FRU SIRSTAT to determine if this v HSL_LNK
error requires service. If the last entry indicates the v SIIOADP
loop is functioning (determined by FRU SIRSTAT) then
no service action is required, close this problem v SICNTRL
v OPT_CLN
There may be multiple B6xx 6985 logs with xxxx 3205
in word 4 errors for the same loop resource in the
serviceable event view. This is caused by retry and A6xx6986 A6xx6986
recovery attempts. If there is a B6xx 6985 with xxxx
Explanation: System bus error
3206 or xxxx 3208 in word 4 after the above B6xx 6985
entries in the PAL, then the recovery efforts were Response: For Power5 and newer servers, service this
successful. If this is the case, close all the B6xx 6985 error using the B7006986 service information.
entries for that loop resource in the serviceable event Otherwise, continue with this information.
view.
During IPL, system LIC detected an HSL I/O bridge
1. If you find a B6xx 6981 in the serviceable event that was already initialized. The bridge should have
view then close that problem and go to step 2. been in a flushed and uninitialized state after powering
Otherwise perform the following: on. There is a problem with SPCN components that
v Perform RIOIP06 to determine if any other prevented the tower from powering off after a previous
systems are connected to this loop and return power off was issued. The tower will not be configured
here. (HSL_LNK or HSLxxxx FRU in the Service for this IPL.
Action Log (SAL) entry, or serviceable event view
This reference code is equivalent to 1xxx 90F0. When
you are working with, indicates the loop
referring to the "CBLALL" symbolic FRU in the Failing
number.) If there are other system(s) then
Item list, perform the "CBLALL" procedure using
continue with the steps that follow, otherwise go
reference code "90F0".
to step 2.
v Check for HSL failures on the other system(s) Word 5 of the SRC identifies the frame. Determine the
before replacing parts. HSL failures are frame by breaking down word 5:
serviceable event entries with HSL I/O Bridge Word 5 -> xxxx xxNN where: NN is the frame number
and Network Interface Controller (NIC) in hexadecimal format.
resources. Ignore B6xx 6982 and B6xx 6984
entries. If there are HSL failures on other Failing Item:
system(s) then continue with the steps that v TWRCARD
follow, otherwise go to step 2.
v CBLALL
v Repair the problems on the other systems and
return to this step. After making repairs on the
other system(s) check the Product Activity Log A6xx6987 A6xx6987
(PAL) of this system for a B6xx 6985 logged after Explanation: High Speed Link (HSL) connection
the repairs you made on the other system(s). If failure
you find one then continue with the steps that
follow, otherwise go to step 2. Response: For Power5 and newer servers, service this
error using the B7006987 service information.
v For the B6xx 6985 log you found, use FRU
Otherwise, continue with this information.
SIRSTAT to determine if the loop is now
complete. If the loop is complete then this Failures are occurring on the HSL link.
problem has been resolved. Use RIOIP01 to verify
that the loop is now working properly. There may be B6xx 6982 errors logged on the same
Otherwise, go to step 2. loop and about the same time as this error. Close those
errors and continue to correct the problem by working
2. Use the serviceable event's FRU list when it is this error.
available.
v If there is a cable FRU in the serviceable event entry:
If this SRC appears in the Service Action Log (SAL),
or the serviceable event view you are using, with 1. If the connection is copper and either end has a
the Symbolic FRU HSL_LNK or HSLxxxx listed as a loose connection, re-seat the cable. To do this,
FRU, then perform problem isolation procedure disconnect the connection and wait a minimum
RIOIP01. Otherwise exchange the FRUs listed in the of 30 seconds. Then reconnect the cable and
serviceable event view. complete the tightening process in at most 30
seconds. Repeat the process at the other end of
v REM_SYS
A6xx69C9 A6xx69C9
v LOC_SYS
Explanation: HSL Opticonnect abnormal disconnect
from other sys. or partition.
A6xx69C8 A6xx69C8
Response: The local system or partition disconnected
Explanation: HSL Opticonnect abnormal disconnect from a remote system or partition due to an failure in a
from other sys. or partition. LIC virtualized bus unit. LIC will attempt to recover
Response: The local system or partition disconnected from the error. Possible causes are:
from a remote system or partition due to an v LIC problem where the local bus unit is off line.
unexpected event or failure. All of the HSL v LIC problem where the remote bus unit is off line.
OptiConnect connections on this loop will be in a failed
state. LIC will attempt to recover from the error. Examine the Service Action Log (SAL), or serviceable
Intervention at the local or remote system or partition event view you are using, on the local system or
may be required. Possible causes are: partition for HSL Opticonnect failures that occurred at
v time out of a critical message approximately the same time this error occurred.
v LIC code / table problem
Examine the remote system or partition for problems.
v Network deadlock detected
Examine the Service Action Log (SAL), or the
serviceable event view you are using, on the remote
The problem may be with:
system or partition for HSL Opticonnect problems that
v The local system or partition occurred at approximately the same time this error
v The remote system or partition occurred.
Examine the Service Action Log (SAL), or serviceable Collect all the Product Activity Log information for this
event view you are using, on the local system or failure on all systems and partitions on this HSL loop.
partition for HSL failures on the same HSL loop, or Be sure to record all words in the SRCs. Contact your
with the Network Interface Controller at approximately next level of support with the information you have
the same time this error occurred. collected.
Failing Item:
Examine the remote system or partition for problems.
Examine the Service Action Log (SAL), or serviceable v AJDG301
event view you are using, on the remote system or v REM_SYS
partition for problems on the same HSL loop or with v LOC_SYS
the Network Interface Controller at approximately the
same time this error occurred.
A6xx69CF A6xx69CF
Correct any problems you find with the remote and Explanation: HSL Opticonnect abnormal disconnect
local systems or partitions that happened at from other sys. or partition.
approximately the same time and involve HSL
Opticonnect or HSL loop components or Network Response: LIC internal error. All systems participating
Interface Controllers. in HSL OptiConnect will be disconnected. The system
must be re-IPL'd to recover. Before re-IPL'ing the
If there are no problems with the remote system or system initiate a main store dump.
partition and there are no problems with the local After getting the dump, examine the Service Action
system or partition then collect all the Product Activity Log (SAL), or serviceable event view you are using, on
Log information for this failure on all systems or the local system or partition for HSL Opticonnect
partitions. Be sure to record all words in the SRCs. failures that occurred at approximately the same time
Contact your next level of support. this error occurred.
Failing Item: Examine the remote systems or partitions for problems.
v REM_SYS Examine the Service Action Log (SAL), or serviceable
v LOC_SYS event view you are using, on the remote systems or
partitions for HSL Opticonnect problems that occurred
v AJDG301 at approximately the same time this error occurred.
Collect all the Product Activity Log information for this
failure on all systems and partitions on this HSL loop.
Be sure to record all words in the SRCs. Contact your
next level of support with the information you have
collected.
Failing Item:
A6xx69DD A6xx69DD
v AJDG301
Explanation: The HEA connection to the Ethernet
switch has been restored
A6xx69D0 A6xx69D0
Response: System log entry only, no service action
Explanation: Bus Expansion Adapter card failed required.
Response: Contact your next level of support.
Failing Item: A6xx69DE A6xx69DE
Explanation: Host Ethernet Adapter (HEA) failure Response: Contact your next level of support.
A6xx69DB A6xx69DB
A6xx69F0 A6xx69F0
Explanation: LIC failure
Explanation: Bus Expansion Adapter failed
Response: A Licensed Internal Code error occurred.
Response: Contact your next level of support.
The partition will continue to run with this Host
Ethernet Adapter (HEA) disabled. Perform a partition Failing Item:
dump and then IPL the partition to recover the HEA. v NEXTLVL
Send the partition dump to your next level of support.
Failing Item: A6xx69F8 A6xx69F8
v SVCDOCS
Explanation: Bus Expansion Adapter failed
Response: Contact your next level of support.
A6xx69DC A6xx69DC
Failing Item:
Explanation: The HEA is not connected to the
Ethernet switch v NEXTLVL
Failing Item: The user must run problem analysis for this reference
code. If this indicates a software problem, the user
v UG3LB should dial IBM Software Support for assistance.
The Problem Determination Procedure (PDP) will
A6xx7004 A6xx7004 indicate whether the original timeout condition still
Explanation: TCP/IP informational error exists and what the corrective actions should be.
A6xx8004 A6xx8004
A6xxCF00 A6xxCF00
Explanation: An external storage subsystem disk unit
connection failed Explanation: Permanent error on removable media
device.
Response: Could not read configuration information
from the disk unit. Look for other errors in the Service Response: A type D IPL terminated because of a
Action Log, or serviceable event view you are working removable media Load Source device failure. If the
with, and fix them. removable media Load Source is an external device,
check the cables. If that does not correct the problem,
replace the device. If the removable media Load Source
A6xx8005 A6xx8005 is an internal device, replace the device. If the
Explanation: High performance connection failed removable media Load Source is a virtual device,
ensure it is set up correctly.
Response: A high performance connection to an
external storage subsystem disk unit failed. Failing Item:
v SVCDOCS
There are still two or more external storage subsystem
disk unit connections, but performance might be
degraded. A6xxCF01 A6xxCF01
Look for other errors in the Service Action Log, or Explanation: Unsupported removable media device
serviceable event view you are working with, and fix configuration.
them.
Problem determination: A type D IPL terminated
because of an unsupported removable media device
A6xx8006 A6xx8006 configuration. Retry the D-IPL with a different
removable media device.
Explanation: High performance connection failed
Failing Item:
Response: A high performance connection to an
external storage subsystem disk unit failed. v SVCDOCS
Look for other errors in the Service Action Log, or Explanation: Optical library device condition not
serviceable event view you are working with, and fix expected
them. Response: The optical disk drive addressing within
the optical library is incorrect. This error is likely to be
A6xx8007 A6xx8007 the result of faulty cabling or switch setting following
service to an optical library.
Explanation: High performance connection was
restored Contact your hardware service provider.
No action required.
A6xxCFFD A6xxCFFD
A6xxCFFF A6xxCFFF
Explanation: Media determined to be bad in Optical
library
A6xxF103 A6xxF103
Explanation: Main storage dump must be copied for
service
Failing Item:
v LICIP01
A6xxF104 A6xxF104
Explanation: LPAR service function directed a Main
Storage Dump.
Response: The Hypervisor terminated a partition with
an unresponsive Operating System. A Main Store
Dump must be done for service. Call your next level of
support when the dump is complete.
Failing Item:
v LICIP01
A6xxF105 A6xxF105
Explanation: Licensed Internal Code detected error
Failing Item:
v NEXTLVL
A6xxFDC0 A6xxFDC0
Explanation: LIC program reported informational
error
Response: This reference code is logged for
information only. No action required.
A6xxFDC5 A6xxFDC5
Explanation: LIC program failed and data was
captured
Response: This reference code indicates first failure
data capture (FFDC) data was collected for a problem
reported by licensed internal code.
The user should dial IBM Software Support for
assistance.
Failing Item:
v UG3AS
Failing Item:
A700173A A700173A
v NEXTLVL
Explanation: A VPD collection overflow occurred
A7001160 A7001160 Response: Look for and resolve other errors in the
serviceable event view. If that does not resolve the
Explanation: Service processor failure
problem, check for firmware updates and install them,
Response: Work with the FRU list in the serviceable if available. If that does not resolve the problem,
event view if there is one, otherwise use the FRU list contact your next level of support.
documented here to determine the parts to exchange.
Failing Item:
The platform encountered an error communicating with v SVCDOCS
the service processor. The platform code attempts a
graceful shutdown of partitions and powers off the
server after a certain time, or when the last partition A700173C A700173C
indicates shutdown, whichever comes first. Explanation: Generic Asset Protection Event. No
Failing Item: service action is required.
v LICCODE Response:
v SVCPROC Problem determination:
v PSI_LNK
Response: The system power on has reached a Explanation: Platform LIC detected an error
standby state. The firmware does not have partition Response: The Capacity on Demand function is no
configuration information. longer available. If Capacity on Demand functions are
Use the Hardware Management Console (HMC) to required, look for and correct errors with SRCs of the
activate one or more partitions to change the system form B1xxxxxx in the Serviceable Event View. If that
from a standby state to an operating state. If the HMC does not correct the problem, or no errors were found,
does not manage the server, perform Restoring your contact your next level of support.
server to factory settings. Failing Item:
Failing Item: v SVCDOCS
v SVCDOCS
A7004705 A7004705
A7004700 A7004700 Explanation: Platform LIC failure
Explanation: Platform LIC detected an error Response: A problem occurred when initializing,
Response: A problem occurred when initializing, reading, or using system VPD. The Capacity on
reading, or using system VPD. Demand function is not available. If Capacity on
Demand function is required, re-IPL the system. If that
Capacity on Demand is not available because the stored does not correct the problem, contact your next level of
activation code is not valid. Contact your next level of support.
support to verify your activation code. If the activation
code is valid, replace the VPD card. Failing Item:
v SVCDOCS
Failing Item:
v SVCDOCS
A7004710 A7004710
v CAPACTY
Explanation: Platform LIC detected an error
A7004701 A7004701 Response: A communications problem with the
service processor occurred while initiating Capacity on
Explanation: Platform LIC detected an error Demand. The Capacity on Demand function is not
Response: A problem occurred when initializing, available.
reading, or using system VPD. The IPL failed. If Capacity on Demand function is required, look for
Work with the FRU list in the serviceable event view if errors with SRCs of the form B1xxxxxx or B7xx69xx in
there is one, otherwise use the FRU list documented the Serviceable Event View. Work those errors. If that
here to determine the parts to exchange. does not correct the problem, proceed with the failing
items listed in the serviceable event view for this SRC.
Failing Item:
Failing Item:
v CAPACTY
v SVCDOCS
v CAPACTY
Explanation: Platform LIC detected an error Explanation: Platform LIC detected an error
Response: The VPD card has been exchanged with a Response: The system has been running with full
not valid card. Reinstall the original VPD card in the Capacity on Demand resources activated. In one hour,
system. the system will terminate and unlicensed resources will
no longer be available. To prevent the system from
Failing Item: terminating, enter an activation code of all zeroes. Then
v SVCDOCS obtain the proper activation codes for the resources
being used or allocate fewer resources in the LPAR
configuration.
A7004714 A7004714
Failing Item:
Explanation: Platform LIC has detected a new VPD
card v SVCDOCS
A7004721 A7004721
A7004741 A7004741
Explanation: The World Wide Port Name (WWPN)
Prefix is not valid. Explanation: Platform LIC detected an error
Response: Contact your hardware service provider to Response: The number of allowable attempts to enter
obtain a valid World-Wide Port Name (WWPN). Once a valid activation code has been exceeded. The system
you have obtained a valid WWPN value, go to ASM will continue to run, but a system IPL is required in
and select: System_Configuration-> order to retry entering a valid activation code.
Program_Vital_Product_Data-> System_Keywords. On
the System_Keyword menu, enter the value for the A7004742 A7004742
'WN' keyword.
Explanation: Platform LIC detected an error
Failing Item:
Response: A communications problem with the
v SVCDOCS
service processor occurred. No Capacity on Demand
changes can be made, but you can continue to run with
the current Capacity on Demand resources. what was expected. The IPL will continue. Should other
errors occur, contact your next level of support.
Look for errors with SRCs of the form B1xxxxxx or
B7xx69xx in the Serviceable Event View. Work those
errors first. If that does not correct the problem, re-IPL A70047C1 A70047C1
the system. If that does not correct the problem, contact
Explanation: Capacity on Demand data mismatch
your next level of support.
Response: The data obtained from the system is not
Failing Item:
what was expected. The system will perform a slow
v SVCDOCS IPL in order to obtain the correct data. If other errors
occur, contact your next level of support.
A7004747 A7004747
Explanation: User intervention required A70047CB A70047CB
Response: One hour remains until the On/Off Explanation: Fast system IPL changed to slow system
Capacity on Demand request expires. Permanently IPL
activate the temporary Capacity on Demand resources, Response: The data obtained from the system is not
enter a new On/Off Capacity on Demand request for what was expected. The system will perform a slow
the temporary resources, or remove all temporary IPL in order to obtain the correct data. If other errors
resources from partitions before the request expires. occur, contact your next level of support.
Failing Item:
v SVCDOCS A70047CD A70047CD
Explanation: Platform LIC detected an error
A7004748 A7004748
Response: The server detected a not valid Capacity
Explanation: User intervention required On Demand activation and terminated the system. The
allocated resources for the system might exceed those
Response: One hour remains until the Utility Capacity
that are available for use.
on Demand enablement expires. In order to reactivate
temporary resources, a new Utility Capacity on Failing Item:
Demand enablement code is required. v SVCDOCS
Failing Item:
v SVCDOCS A70047FF A70047FF
Explanation: System log entry only, no service action
A7004749 A7004749 required
Explanation: User intervention required Response: The Capacity on Demand History Log has
been written to the error log. No service action is
Response: One hour remains until the Trial Customer
required.
on Demand activation expires. Obtain a permanent
activation code or remove all temporary resources from
partitions before the request expires. A700C2AC A700C2AC
Failing Item: Explanation: System log entry only, no service action
v SVCDOCS required
Response: The Capacity on Demand License
A7004750 A7004750 acceptance has completed.
Note: Click the failing item in the FRU list only when you experience a hang
condition on an attention code. For example, a hang condition occurs when your
server performs a requested action but the SRC in the control panel display does
not change for several minutes and the partition firmware appears to be hung.
AA00E175 AA00E175
AA06000B AA06000B
Explanation: The I/O configuration exceeds the
recommended size. Some operating systems might Explanation: The system or partition was not able to
crash when using this configuration. find an operating system on any of the devices in the
boot list.
Failing Item:
v FWFLASH
AA06000C AA06000C
Explanation: The media specified in a device in the
AA00E1A8 AA00E1A8
bootlist was not bootable
Explanation: The system is booting to the open
firmware prompt
AA06000D AA06000D
Failing Item:
Explanation: The media in the device in the bootlist
v FWFLASH not found under the I/O adapter specified by the boot
list.
AA00E1A9 AA00E1A9
Explanation: The system is booting to the SMS menus AA06000E AA06000E
AA060010 AA060010
AA00E1B0 AA00E1B0
Explanation: The FAT filesystem on the bootdisk is
Explanation: Waiting for the user to select language
configured in a way that may cause a boot failure.
and keyboard.
AA060011 AA060011
AA00E1B1 AA00E1B1
Explanation: The firmware did not find the operating
Explanation: Waiting for the user to accept or decline
system image and is was unable to detect at least one
the license agreement.
hard disk in the boot list. Firmware is now retrying the
entries in the boot list. This often occurs when the boot
AA170211 AA170211
Explanation: Setenv/$Setenv parameter error - value
contains a null character
Failing Item:
v FWFLASH
AA170212 AA170212
Explanation: Setenv/$Setenv parameter error: name is
null or too long. The name length is limited to 31
characters.
Failing Item:
v FWFLASH
The manufacturer may not offer the products, services, or features discussed in this
document in other countries. Consult the manufacturer's representative for
information on the products and services currently available in your area. Any
reference to the manufacturer's product, program, or service is not intended to
state or imply that only that product, program, or service may be used. Any
functionally equivalent product, program, or service that does not infringe any
intellectual property right of the manufacturer may be used instead. However, it is
the user's responsibility to evaluate and verify the operation of any product,
program, or service.
The following paragraph does not apply to the United Kingdom or any other
country where such provisions are inconsistent with local law: THIS
INFORMATION IS PROVIDED “AS IS” WITHOUT WARRANTY OF ANY KIND,
EITHER EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE
IMPLIED WARRANTIES OF NON-INFRINGEMENT, MERCHANTABILITY OR
FITNESS FOR A PARTICULAR PURPOSE. Some states do not allow disclaimer of
express or implied warranties in certain transactions, therefore, this statement may
not apply to you.
Any references in this information to Web sites not owned by the manufacturer are
provided for convenience only and do not in any manner serve as an endorsement
of those Web sites. The materials at those Web sites are not part of the materials for
this product and use of those Web sites is at your own risk.
The manufacturer may use or distribute any of the information you supply in any
way it believes appropriate without incurring any obligation to you.
All statements regarding the manufacturer's future direction or intent are subject to
change or withdrawal without notice, and represent goals and objectives only.
The manufacturer's prices shown are the manufacturer's suggested retail prices, are
current and are subject to change without notice. Dealer prices may vary.
This information is for planning purposes only. The information herein is subject to
change before the products described become available.
This information contains examples of data and reports used in daily business
operations. To illustrate them as completely as possible, the examples include the
names of individuals, companies, brands, and products. All of these names are
fictitious and any similarity to the names and addresses used by an actual business
enterprise is entirely coincidental.
If you are viewing this information in softcopy, the photographs and color
illustrations may not appear.
The drawings and specifications contained herein shall not be reproduced in whole
or in part without the written permission of the manufacturer.
The manufacturer has prepared this information for use with the specific machines
indicated. The manufacturer makes no representations that it is suitable for any
other purpose.
Trademarks
IBM, the IBM logo, and ibm.com are trademarks or registered trademarks of
International Business Machines Corp., registered in many jurisdictions worldwide.
Other product and service names might be trademarks of IBM or other companies.
A current list of IBM trademarks is available on the Web at Copyright and
trademark information at www.ibm.com/legal/copytrade.shtml.
Java and all Java-based trademarks and logos are trademarks of Sun Microsystems,
Inc. in the United States, other countries, or both.
Class A Notices
The following Class A statements apply to the IBM servers that contain the
POWER6 processor.
Note: This equipment has been tested and found to comply with the limits for a
Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference when the
equipment is operated in a commercial environment. This equipment generates,
uses, and can radiate radio frequency energy and, if not installed and used in
accordance with the instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential area is likely to cause
harmful interference, in which case the user will be required to correct the
interference at his own expense.
Properly shielded and grounded cables and connectors must be used in order to
meet FCC emission limits. IBM is not responsible for any radio or television
interference caused by using other than recommended cables and connectors or by
unauthorized changes or modifications to this equipment. Unauthorized changes
or modifications could void the user's authority to operate the equipment.
This device complies with Part 15 of the FCC rules. Operation is subject to the
following two conditions: (1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that
may cause undesired operation.
The following is a summary of the VCCI Japanese statement in the box above:
This is a Class A product based on the standard of the VCCI Council. If this
equipment is used in a domestic environment, radio interference may occur, in
which case, the user may be required to take corrective actions.
Dieses Gerät ist berechtigt, in Übereinstimmung mit dem Deutschen EMVG das
EG-Konformitätszeichen - CE - zu führen.
Verantwortlich für die Konformitätserklärung nach des EMVG ist die IBM
Deutschland GmbH, 70548 Stuttgart.
Generelle Informationen:
Das Gerät erfüllt die Schutzanforderungen nach EN 55024 und EN 55022 Klasse
A.
Personal Use: You may reproduce these publications for your personal,
noncommercial use provided that all proprietary notices are preserved. You may
not distribute, display or make derivative works of these publications, or any
portion thereof, without the express consent of the manufacturer.
Commercial Use: You may reproduce, distribute and display these publications
solely within your enterprise provided that all proprietary notices are preserved.
You may not make derivative works of these publications, or reproduce, distribute
or display these publications or any portion thereof outside your enterprise,
without the express consent of the manufacturer.
The manufacturer reserves the right to withdraw the permissions granted herein
whenever, in its discretion, the use of the publications is detrimental to its interest
or, as determined by the manufacturer, the above instructions are not being
properly followed.
You may not download, export or re-export this information except in full
compliance with all applicable laws and regulations, including all United States
export laws and regulations.
Printed in USA