PHYSICS

LABORATORY
MANUAL
For Undergraduates
2019-20

Department of Physics
The LNM Institute of Information Technology
Rupa ki Nangal, Post-Sumel, Via-Jamdoli,
Jaipur - 302031, Rajasthan, India
Laboratory Regulations

1. Mobile phones are not allowed in the UG Physics laboratory.

2. Attendance in each lab session is compulsory.

3. Performance in each lab session will be evaluated and it carries 60% (40% on
lab record and 20% for viva voce during lab sessions) weightage on grade
evaluation for this course.

4. Students should be punctual. They will be marked absent if they are not present
within the first five minutes of each laboratory session.

5. Experiments will be performed in groups defined by the lab instructors. Students


are not allowed to change their partner during the semester under any circumstance.

6. It is compulsory to bring the lab manual and required graph papers. The lab
register will be kept in the laboratory and students are not supposed to carry the
lab register with them after completion of the experiment. Such activities will be
penalized.

7. Pre-recorded audio visual demo for every experiment will be sent to you in due time.
Prior to performing each experiment, you should be familiar with the basic principles
from them. There will be no additional demo for any of the experiments
during the lab session.

8. During each lab session you are expected to perform the experiment, record the
observed data in your lab register (not in any rough note book) and complete the
experiment including the written record. For each experiment, you have to write in
your lab register the purpose, description of apparatus, working formula (if
any), and tables for observations.

9. Students are supposed to handle the instruments carefully. In case of any technical
difficulty take help from the lab attendant. After performing the experiment hand
over the instrument(s)/components and or switch off (in case of electrical devices)
properly. Any intentional manhandling of any experimental set ups will lead to
disbarring of the student from the subsequent lab sessions depending on the severity.

10. Student while performing the experiments are supposed to get a few readings signed
by the respective instructor or TA in their lab register.

11. The lab register completed in all respects should be submitted at the end of each
lab session (take a note of the point 6 above).

12. The student is expected to be in the lab for the entire 3 hours. Leaving the laboratory
early without informing is liable for deduction in class performance marks.

3
Contents

A. Measurement & Instruments 5

B. Error bars on graphs 13

C. A comment of significant digits 14

D. Vernier caliper & Screw Gauge 16

1. Introduction to Error Analysis and Graph Drawing 21


1.1. Finding τ and initial voltage across capacitor . . . . . . . . . . . . . . . . . 21
1.2. Resonant Rings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
1.3. Mass Spring System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
1.4. Resistivity of a nichrome wire . . . . . . . . . . . . . . . . . . . . . . . . . . 23
1.5. To measure the electrical resistance of a given material . . . . . . . . . . . . 24

2. Acceleration due to gravity by bar pendulum 26

3. Helmholtz coil 32

4. Measurement of band gap of semiconductor 35

5. Refractive index of glass with the help of a prism 42

6. Wavelength of sodium light by Newton’s rings 51

7. Gyroscope 57

8. Electromagnetic induction 61

9. Mechanical waves 64

10. Fraunhoffer Diffraction 68

11. Diffraction grating 72

4
A. Measurement & Instruments

This section of the manual describes the basic measurements and allied instruments that
you will encounter in the laboratory.

Physical Measurements
In the grouping of physical measurements the quantities to be measured are length, mass,
angle and time.

Length
There are three basic instruments for the measurement of length, (i) the meter ruler, (ii)
the micrometer screw gauge and (iii) the vernier calipers. The table below details the
range and accuracy of these three instruments.

Name Range Accuracy


Meter Ruler 0 − 100 cm 1 mm
Micrometer Screw Gauge 0 − 25 mm 0.01 mm
Vernier Calipers 0 − 150 mm 0.02 mm

Clearly, there is a wide variation in the range of the instruments and the first lesson is
that the choice of instrument is determined by the length that is to be measured. If the
length is 50cm, then it clearly should be the Metre Ruler. The second lesson concerns the
accuracy. In principle, you can measure a length of 2cm with all three instruments but
the accuracy of your measurement will vary from 1mm to 0.01mm. The choice, then, is
also determined by the accuracy required. The accuracy of an instrument depends on its
construction & operation and this is now described for each instrument

Meter ruler: The principle of the metre ruler is very simple. A known length (1 metre)
is divided into 100 unit lengths of 1cm. and these are further subdivided into 10 unit
lengths of 1mm. The accuracy of the instrument is the smallest division, namely 1mm.
Operation: Place one end of the ruler (or an appropriate ‘zero’) at one end of the
length to be measured and read off the nearest value at the other end of the length to be
measured.

Micrometer screw gauge: The principle of the micrometer is the screw thread. The
pitch of the screw is 0.5mm. that is one complete rotation of the screw advances or retracts
the screw by 0.5mm. Underneath the rotating barrel of the gauge is a ruler with 0.5mm
divisions (actually two sets of 1mm divisions offset by 0.5mm). The rotating barrel is
itself subdivided into 50 units, such that rotation of the barrel through one unit advances
or retracts the screw by 0.5/50 = 0.01mm; the accuracy of the instrument is therefore
0.01mm.

5
Operation: Place the object between the fixed and moving end faces and rotate the
barrel until the object is in contact with both end faces. Always rotate using the small
slip knob at the end of the barrel. This will ensure contact without damage to the
object or the micrometer. The measured length is the reading on the ruler to the nearest
full 0.5mm unit plus the portion of this unit shown on the rotating barrel. Always check
the visible zero setting and all for any offset from zero.

Vernier calipers: The principle of the Vernier calipers is two-fold. First, the sliding
piece allows the jaws to contact the sides of the object to be measured, in much the same
way as the micrometer. The distance moved by the sliding jaw is then read off the fixed
ruler on the main body of the instrument. The accuracy of that ruler as such, however,
is only 1mm. The much improved accuracy is provided by the ’Vernier’ scale. This scale
is marked on the sliding jaw; it has 10 divisions, each subdivided into 5, ie a total of 50
subdivisions. These subdivisions look like 1mm in length. But if you compare the fixed
and Vernier scales, you will see that the 50 subdivisions on the Vernier scale correspond
to 49 subdivisions (each of 1mm) on the fixed scale! This is not a mistake but rather it
is deliberately designed so that a subdivision on the Vernier scale is smaller than that on
the fixed scale by 1/50 = 0.02mm; this is the accuracy of the instrument. How a reading
with this accuracy is achieved in practice is detailed below:
Operation: With no object between the jaws, the zeros of the Vernier and fixed scales
are coincident. There is an increasing mismatch between the marks of these two scales
until at the end of the Vernier scale there is again coincidence between the end mark on the
Vernier and the 49mm mark on the fixed scale. Clearly, to obtain coincidence between the
first subdivisions of the Vernier and of the fixed scales it would be necessary to move the
sliding jaw by the deficit of 0.02mm; coincidence between the second subdivisions would
require 2 x 0.02 = 0.04mm, and so on. A total of 50 x 0.02 = 1mm is required to achieve
coincidence between the end mark of the Vernier scale and the 50mm mark of the fixed
scale. Conversely, a measurement of the length of an object in contact with the jaws is
the reading to the nearest full mm on the fixed scale at the Vernier zero PLUS the reading
(in units of 0.02mm) on the Vernier scale where there is coincidence between the
vernier and fixed scales.

Other vernier instruments: There are three other instruments in the laboratory which
incorporate Vernier scales. These are the travelling microscope, the weighing scales and
the spectrometer. The travelling microscope combines magnified optical positioning with
a ruler accuracy of 0.01mm.
For the other two instruments some other parameter has been equated with a length
scale.
In the case of the weighing scales, mass can be equated with the length of the balance
arm that is divided into 10 units of 10g. The rotating scale adds up to a further 10g with
an accuracy of 0.1g and the Vernier scale accuracy is 0.01g.
In the case of the spectrometer, angle can be equated with the length of a circular
scale that has an accuracy of 0.5 degree. The Vernier scale is in the natural sub-unit of
minutes of arc (60 minutes of arc = 1 degree) and the accuracy is one minute of arc (1’).

Time
The stop-clock has a start/stop/reset push-button device with a digital display. In prin-
ciple, the accuracy is the smallest digit, ie 0.01s, but the response time of the button is of
the order of 0.1s and that of the user may be significantly longer, say, of the order of 1s.
Timing accuracy is further discussed later in the section Accuracy & Uncertainty.

6
Electrical Measurements
In the grouping of electrical measurements, the principal instruments are the multimeter,
oscilloscope, function generator and the power supply.

Multimeter
The multimeter provides conveniently in a single instrument a number of ranges of mea-
surement of voltage (DC/AC), current and resistance. It is necessary to select the appro-
priate quantity and range as well as the proper connections for the two input leads. The
AC ranges are distinguished from the DC ranges by the symbol (∼).

Voltage: The voltage ranges are marked V . The two input sockets are marked COM
and V , Ω.
Voltage is measured across a component, that is, the meter is connected in parallel
with the component. The meter displays the polarity of the voltage relative to the COM
connection.

Current: The current ranges are marked A. The two input sockets are marked COM
and either A or 10A, depending on the magnitude to be measured; the A connection is
protected by a 2amp fuse and is only to be used for currents less than this limit. The 10A
connection is protected by a 10amp fuse, and is only to be used for currents up to this
limit. This latter connection only works with the current range marked 10.
Current is measured through a component, that is the meter is connected in series
with the component. The meter displays the polarity of the current entering the A (or
10A) socket.

Resistance: The resistance ranges are marked Ω. The two input sockets are marked
COM and V, Ω.
Resistance is measured across a component, that is, the meter is connected in parallel
with the component. There is no polarity associated with this measurement.
It is important to realize that resistance measurement is really the measurement of the
voltage resulting from a current supplied by the meter. Therefore, this mode of resistance
measurement cannot be carried out on components while they are in circuit.

Range & display: The maximum display of 1999 corresponds to the end of the range
selected. For example, selecting the voltage range marked 2 allows a measurement of
voltage up to 1.999 volts. The next voltage range is marked 20. This range is appropriate
for voltage between 2 and 20 volts.
The accuracy of the measurement is the least significant digit (note how this digit may
arbitrarily change up or down by one unit during the reading). The best practice is to use
the range which is one setting above that at which the full 1999 shows.

Oscilloscope, function generator & power supply


The oscilloscope is probably the most important of all electronic measuring equipment.
Its main use is to display on a screen the variation or a potential difference (or voltage) as,
a function of time. The result is a graph with voltage on the vertical (or y) axis and time
along the horizontal (or x) axis. This is achieved by electrostatic deflection of an electron
beam striking the front face phosphor in the cathode ray tube in the oscilloscope.
You will learn about oscilloscope, function generator and power supply in your elec-
tronics laboratory.

7
Plotting graphs
A graph is useful way of displaying the results of an experiment in which one parameter
(call it x) is varied in well defined steps and another parameter (call it y) is measured in
response. In this general case each (x, y) pair of values is represented by a point which is a
distance x along the horizontal axis and a distance y along the vertical axis. For example,
if the following data were obtained for the resistance of varying lengths of wire:

L (m) 1 2 3 4
R (Ω) 10 20 30 40

The data would be graphed as shown below:

Figure 1: Resistance (R) vs Length (L)

Note the title, the labeled axes (with units!). These elements are essential for any
graph! The usefulness of this particular graph is that it is clear at a glance that the
resistance of the wire is proportional to its length. This is formally shown in the graph
below where the data fall on a straight line through the origin.
Mathematically, this linear relation is expressed by the equation y = mx, where m is
the slope. The slope of the straight line is obtained by constructing a right-angle triangle
containing the straight line and lines parallel to the vertical and horizontal axes; the slope
is the ratio of the lengths of the vertical and horizontal sides (shown dashed below). Note
that for good accuracy the complete range of plotted data should be used.

Figure 2: Resistance (R) vs Length (L) showing slope

In this particular example the slope is (40-10)/(4-1) = 30/3 = 10.


The resistance per unit length of the wire is 10 ohm per metre or simply 10Ωm−1 . (In
shorthand R(Ω)=10Ωm−1 L(m).
This trivial example has been used to introduce you to the basics of graph plotting.
Only rarely will your experimental data be in this ready-to-graph form. For example,

8
consider the following measurements of the resistance versus the temperature of a fixed
length of the wire:

T (o C) 100 200 300 400


R (Ω) 34 36 38 40
The data could be plotted as shown in Fig. 3. This time, the straight line does not

Figure 3: Resistance (R) vs Temperature (T)

go through the origin and the mathematical expression is y = mx + C, where C is the


intercept on the y axis. In this case the intercept, C is 32Ω and the slope, m is 2Ωo C −1 .
We can therefore write R(Ω) = 2(Ωo C −1 )T (o C) + 32Ω.
This example also illustrates an important value judgment about the axes of a graph.
As drawn above most of the graph page is wasted. A better graph (and a more accurate
one) is shown in figure on next page. The origin is now the point (30, 0) rather than (0,

Figure 4: Resistance (R) vs Temperature (T)

0) and the labeling must show that clearly! Clearly the choice is dictated by whether the
intercept is to be determined. Also, the intercept of interest may be on the horizontal
(or x) axis. These considerations apart, you should always aim to use the full size of the
available graph page.
What to do with a system which is not in linear form? A good example is the relation
between period (T ) of a simple pendulum and its length (L). These are related by the
expression . When we plot a graph of T vs L we get a curve. But if we plot a graph
of T 2 vs L, we should get a straight line of the form y = mx. That is, we re-write the
expression in the form of a straight line as T 2 = (4π 2 /g)L. In this way it is clear if our
data matches the theory. Moreover, from the measurement of the slope m we obtain a
value of g = 4π 2 /m.

9
Finally, it is useful to start thinking of a graph as a way of averaging your data and
this concept will be fully discussed in the next section on Accuracy and Uncertainty.

Accuracy and uncertainty (and errors!)


A physical measurement is never exact. Its accuracy is always limited by the nature of
the apparatus used, the skill of the person using it and other factors. The best we can do
is report a range of values, so there remains some uncertainty. So typically we may write:
The velocity of the ball was found to be 5.13 ± 0.02ms−1 . This defines the range 5.11 to
5.15.
The end points of the range can rarely be assigned with much precision (in this labo-
ratory, at least), so if a calculated estimate of the uncertainty were to give us 0.018732 in
the above, we would make it 0.02, retaining just a single significant figure. We must also
trim the digits of the main (central) value to the same point so that 5.128765 become 5.13
in the stated result.
The three rules for a measured (or calculated) value are:
• Include the uncertainty estimate to one significant figure.
• Trim the digits of the value to the same significant figure.
• Don’t forget the units.
How do we estimate uncertainty? In the case of most* individual measurements it
arises naturally from the fact that the instrument has a printed scale (*special cases are
discussed later!). A reasonable estimate of the uncertainty is plus-or-minus half the interval
of the scale, if you use it straightforwardly. In the case of modern instruments with an
electronic display, there may be a stated limit to the accuracy. In some such cases, if
you try to read out more digits the ones at the end will fluctuate, telling you they are
unreliable.
To keep things simple it is recommended that you use plus-or-minus the
smallest interval of the scale.
But this is the start of a long story of statistics, to which we will pay little atten-
tion now. We will use our common sense and some very elementary mathematics. The
mathematical rules follow in a separate section. Remember they are intended for rough-
and-ready estimates–don’t labour over enormous calculations – use short cuts and mental
arithmetic whenever you can. If the person on the next bench gets ±0.2 and you get ±0.3,
it’s unlikely to matter at all. Do it quickly.

FAQ on uncertainty and errors


1. Isn’t uncertainty called error?
Yes, it often is, alas. In fact it’s quite traditional. The unfortunate thing is that it
makes uncertainty sound like a mistake.
2. But don’t we make mistakes?
We all do. These will give rise to data points that don’t fit into the overall pattern,
and can be checked and replaced. That’s one reason why we take sets of measure-
ments and fit them to some sort of theory.
3. But suppose I keep making the same error, such as using an instrument
whose zero has not been set properly, or the wrong units?
Yes, we are all human. That would be called s systematic error. We’ve been talking
about random errors or uncertainty here. A systematic error is something you usually
don’t know about, so you cannot state it! If you can, you should be able to eliminate
it.

10
4. How can I detect a systematic error?
If experiment does not conform to theoretical expectations, one or the other needs to
be improved. In the case of the experiment, search for systematic errors. This dia-
logue between theory and experiment is how both progress and reliable measurement
techniques are developed.

5. How do I combine the errors from individual measurements?


There are basic rules for this as outlined below.

Combining errors of indivual measurements


If the measured values of A and B have certain uncertainties, what are the consequent
uncertainties of AB, A + B and sin(A + B)?
For many, this is the hard part of the subject, but it boils down to a few simple rules
and procedures. It is much less painful if you remember precise calculations with rough
estimates make little or no sense. Feel free to take short cuts by making rough-and-ready
approximations as you go along, in order to arrive quickly at an estimate of the final error.

Rules: Here we shall indicate the uncertainty of A by ∆A. That is, the measured range
is A + ∆A.

Rule 1: For addition (or subtraction) add the uncertainties.

If C = A + B, or C = A − B, then ∆C = ∆A + ∆B.
Example: A = 50 ± 1, B = 20 ± 2, then A + B = 70 ± 3 and A − B = 30 ± 3

Rule 2: For multiplication (or division) add the relative uncertainties to get the relative
uncertainty of the final quantity.

If C = A × B, or C = A/B, then ∆C/C = ∆A/A + ∆B/B. Having found this


fraction, simply multiply by C to get ∆C!
Example: A = 50 ± 1, B = 20 ± 2. For C = AB, C = 1000 ± 120. for
C = A/B, C = 2.5 ± 0.3

Note that, in particular, If C = 1/A, then ∆C/C = ∆A/A.

Rule 3: Dealing with functions.


There are two ways of dealing with functions, such as C = sin(A) or C = exp(A).
One can express the uncertainty in terms of the derivative of the function. Perhaps
you can see the logic of this. But a more straight forward approach, which should
almost always work, is as follows.
Work out the values of the function for A+∆A and A−∆A, and take these to define
the range of values of the function C.

All of these rules can easily be justified by elementary mathematics, provided that the
relative uncertainties are small.

Four special cases:

1. Judgement errors
These arise in cases where the experimenter has to make a judgement about when
some condition is fulfilled in location or in time. Once the location or time is fixed
it can be measured to a certain accuracy or error. However, this error may be much

11
less than the error associated with the judgement. A good example is the location
of the viewing screen in the experiment on the convex lens. The experimenter has
to make the judgement when the image on the screen is in focus and the error in
position associated with this judgement may be much larger than the measurement
error of the emphfinal position. The real error has to be estimated by gauging the
range of position over which the image appears to be still in focus.

2. Improving the timing error in a periodic system


The error associated with a single measurement can be dramatically reduced by
measuring the combination of many identical units. A good example of this is the
measurement of the period of a pendulum. Suppose the measurement of a single
swing is 20 ± 1s (where the error of 1 includes the judgement error of when the
swing starts and ends). The total time for 10 swings of the pendulum might be
195s but the error in this measurement would still be 1s. The period would be
(195 ± 1)/10 or 19.5 ± 0.1s. The latter is a more accurate result.

3. Improving the count rate error in a "random emission" system


Radioactive emission is random in time. This means that repeated measurement
of the emission, usually called the count in fixed periods of time shows a range of
values (or error) which is related to the size of the count. The mathematics behind
this is quite complex but the result is very simple: The error in the count
√ is the
square root of the count! For example, if the count is 100, the error is 100 = 10,
answer 100 ± 10. Now, suppose this count is taken in a time of 1s. Ignoring any
error in the time, the count rate (as opposed to the count) is clearly 100 ± 10s−1 .
However, counting √ for the longer time of 10 s might yield a total count of 1020; the
associated error is 1020 = 32, i.e. the total count is 1020 ± 32. The count rate is
(1020 ± 32)/10 = 102 ± 3. The latter is a more accurate result!

4. Average values of non-uniform parameter


Suppose you need to measure the diameter of a ball. A single measurement will
yield a value and associated error. However, a physical ball is not a perfect sphere
and a measurement of diameter at another orientation may yield a different result.
The more useful value of diameter is the average value estimated from a number of
measurements. Suppose the following measurements are taken of the diameter:

25 ± 1 23 ± 1 28 ± 1 22 ± 1 24 ± 1 23 ± 1

The average value is clearly (25 + 23 + 28 + 22 + 24 + 23)/6 = 145/6 = 24.17 but


what is the error? This question brings us into the area of statistics and there is no
easy answer to this other than a full statistical analysis. One thing is certain: the
error in the average is NOT the average of the errors!

We recommend the following approximate method:


First, examine which is greater, the range of values or the error in any individual,
value. In the unlikely event that it is the latter then this is the error in the average! More
likely, the range of values is greater, as is the case here; the values range from 22 to 28, a
range of 6. A crude estimate of the error is therefore ±3. However, if you think about it,
increasing the number of measurements will only increase this estimate of error, whereas
the reverse would be the case in a proper statistical analysis. Visual inception of the data
above shows that 5 out of the 6 values lie within the range 24 ± 2 and this is a more
reasonable answer. When you encounter this type of error in an average, it is
sufficient to make a rough estimate along these lines!

12
B. Error bars on graphs

Whenever you enter data as a data point on a graph, the uncertainty in one or other of
the x and y values can be indicated by error bars, which show the range of values for
that parameter at each data point. This is helpful in judging by eye whether the data is
consistent with some theory, or whether some particular measurement should be repeated.
This applies to graphs drawn by hand or by computer. In practice, it may be simplified
in many cases. For example, if the relative uncertainty in x is much less that that in y–
or vice-versa – it is not worth representing the smaller error bar on the graph or it might
be that the uncertainty is too small to be visible, in that case there should be a statement
on the graph to that effect.
Consider the following modified data set for the resistance versus the temperature of
a fixed length of the wire:

T(o C) 100 ± 1 200 ± 1 300 ± 1 400 ± 1


R (Ω) 34 ± 1 37 ± 1 38 ± 1 41 ± 1

When the bare data is graphed as shown in Fig 5(a) it is not possible to link the points
with a straight line. However, when error bars are included for the R values (the error
in T is much smaller) then it is possible to put a straight line through the error bars, as
shown in Fig 5(b). These data now verify the linear relation. The remaining question is

(a) (b)

Figure 5: Resistance (R) vs Temperature (T) (a) without error bars and (b) with error
bars

which straight line? It is clear that there is a smaller but finite range of lines of different
slope which pass through the error bars. This is important if the slope is used to derive
some parameter, e. g. a value of g in the pendulum experiment.
The slope then becomes m±∆m. Again, this is another example of the error associated
with an average, as discussed above. Again too, it is difficult to be exact about this.

13
C. A comment of significant digits

In many cases the uncertainty of a number is not stated explicitly. Instead, the uncertainty
is indicated by the number of meaningful digits, or significant figures, in the measured
value. If we give the thickness of the cover of this booklet as 3.94mm which has three
significant figures. By this we mean that the first two digits are known to be correct, while
the third digit is in the hundredths place, so the uncertainty is about 0.01mm. Two values
with the same number of significant figures may have different uncertainty, a distance given
as 253km also has three significant figures, but the uncertainty is about 1km. When you
use the numbers having uncertainties to compute other numbers, the computed numbers
are also uncertain.

When we add and subtract numbers, it is the location of the decimal point that matters,
not the number of significant figures. For example 123.62 + 8.9 = 132.5.
Although 123.62 has an uncertainty of about 0.01 and 8.9 has an uncertainty of about
0.1, so their sum has an uncertainty of about 0.1 and should be written as 132.5 and not
132.52.

Exercise:
1. State the number of significant figures:
(a) 0.43
(b) 2.42 × 102
(c) 6.467 × 10−3
(d) 0.029

14
(e) 0.0003

2. A rectangular piece of iron is (3.70±0.01)cm long and (2.30±0.01)cm wide. Calculate


the area.

3. Mass of the planet Saturn is 5.69 × 1026 kg and its radius is 6.6 × 107 m. Calculate
its density.

4. Estimate the percent error in measuring

(a) A distance of about 56cm with a meter stick.


(b) mass of about 16g with a chemical balance.
(c) A time interval of about 4 min with a stop watch.

5. 3.1416 × 2.34 × 0.58 =

6. 2.56 + 16.4329 =

7. 16.4329 − 2.56 =

15
D. Vernier caliper & Screw Gauge

Vernier caliper and screw gauge are used for measuring small lengths with precession.

Vernier caliper
Parts of the instrument1

2 7 5

0 4 8 1/128
inch
0 1 2 3 4 5 6
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 cm

3 5 6 7 1/20
0 1 2 4 8 9 0

1 6 8 4

Figure 6: Parts of a vernier caliper

The parts of the calliper include:


1. Outside large jaws: used to measure external diameter or width of an object
2. Inside small jaws: used to measure internal diameter of an object
3. Depth probe: used to measure depths of an object or a hole
4. Main scale: scale marked every mm
5. Main scale: scale marked in inches and fractions
6. Vernier scale gives interpolated measurements to 0.1 mm or better
7. Vernier scale gives interpolated measurements in fractions of an inch
8. Screw/ Retainer: used to block movable part to allow the easy transferring of a
measurement.

Least count of the instrument


The least count is the smallest length you can measure with the help of the instrument.
For vernier caliper the least count is defined as
Least count of main scale
Least count (LC) =
Number of divisions on vernier scale
1
Image source: https://en.wikipedia.org/wiki/Calipers

16
Figure 7: (a) Positive zero error in vernier caliper. (b) Negative zero error in vernier
caliper.

Measurement with the instrument


1. The outer jaws of the vernier caliper should be closed. In this position the zero of
the main scale should coincide with the zero of the vernier scale. If this is not the
case, then zero error correction has to be applied for each reading.

2. Loosen the screw and place the object to be measured in between the outer jaws.
Tighten the screw again so that the scale does not slide.

3. Note down the position of the zero mark on the main scale. Let it be MSR (Main
Scale Reading).

4. Note down the position of the vernier scale division which coincides with the main
scale division. Let it be VSR (Vernier Scale Reading).

5. The total length of the object is then

Length = MSR + VSR × LC (1)

6. Repeat the steps 2-5 couple of times and take the average of the measured length.

7. Make sure to include proper units and zero correction if required.

Zero error2
Zero errors often arise due to fault in manufacturing. There are two types of zero errors.

Positive zero error


If the zero on the vernier scale is to the right of the main scale, then the error is said to
be positive zero error and so the zero correction should be subtracted from the reading
which is measured. See Fig. 7(a).

Negative zero error


If the zero on the vernier scale is to the left of the main scale, then the error is said to be
negative zero error and so the zero correction should be added from the reading which
is measured. See Fig. 7(b)
2
Image source: http://educationsight.blogspot.in/2014/02/vernier-zero-error-and-its-correction.
html

17
Measurement principle of vernier scale
First of all consider the Fig. 8(a) where the diameter of an object needs to be measured
with the main scale which has least count (LC) of 1 mm. Since the diameter of the object is
exactly 5 mm there is no need of the vernier scale.
Now consider Fig. 8(b), where main scale
reading shows the diameter of the object is
slightly bigger than 5 mm which can not
be measured by main scale alone. Here,
vernier scale plays an important role. If
you watch closely the vernier scale you will
find a vernier division is slightly smaller
than the main scale division. In the present
example,

10 Vernier Scale Divisions (VSD)


= 9 Main Scale Divisions (MSD)

Least count is therefore

LC = 1 MSD − 1 VSD
9
= 1 MSD − MSD
10
= 0.1 MSD = 0.1 mm

Therefore the diameter of the object being


measured in Fig. 8(b) is

D = 5 mm + (1 MSD − 1 VSD)
therefore D = 5.1 mm

Now, to generalize the concept, consider


Fig. 8(c). In this case the diameter of
the object is slightly bigger than the pre-
vious case. To measure this extra length,
vernier constant can again be utilized. If
the fifth division matches with one of the
Figure 8: Vernier measurement main scale division that means the extra
distance over and above 5 mm is equal to
5×LC. So the generalized formula for mea-
surement would be

D = MSR + VSR × LC

where MSR is the Main Scale Reading and VSR is the Vernier Scale Reading.

18
Screw Gauge
Parts of the instrument3

Figure 9: Parts of a screw gauge

The parts of the screw gauge include:


1. Frame: The C-shaped body that holds the anvil and barrel in constant relation to
each other.
2. Anvil: The shiny part that the spindle moves toward, and that the sample rests
against.
3. Spindle: The shiny cylindrical component that the thimble causes to move toward
the anvil.
4. Lock nut: The knurled component (or lever) that one can tighten to hold the spindle
stationary, such as when momentarily holding a measurement.
5. Sleeve: The stationary round component with the linear scale on it, sometimes with
vernier markings. In some instruments the scale is marked on a tight-fitting but
movable cylindrical sleeve fitting over the internal fixed barrel.
6. Thimble: The component that one’s thumb turns. Graduated markings.
7. Ratchet: Device on end of handle that limits applied pressure by slipping at a
calibrated torque.

Least count of the instrument


The pitch of the screw is the distance moved by the spindle per revolution. It can be
represented as
Distance moved by the screw
Pitch of the screw = (2)
No. of full rotations given
The least count (LC) is the distance moved by the tip of the screw, when the screw is
turned through 1 division of the head scale. It can be calculated using the formula
Pitch
Least count (LC) = (3)
Total number of divisions on the circular scale
3
Image source: https://scienceportfolio1p1.wikispaces.com/Term+1

19
Figure 10: Screw gauge (a) without any zero error (b) with positive zero error (c) with
negative zero error.

Measurement with the instrument


1. Insert the object in between the anvil and the spindle and rotate the rachet until
the object is gently gripped between the anvil and the stud. Stop as soon as a click
sound is heard.

2. Note down the circular (CSR) and the linear/main scale (MSR) readings.

3. The length of the object is then given by

Length = MSR + CSR × LC (4)

4. Repeat steps 1-3 three times and note the average reading.

Zero error
When the anvil and the spindle touch without any object between them, the zero of the
circular scale should coincide with the main scale line as shown in Fig. 10(a)

Positive zero error


However, if the circular scale zero is above the linear scale, the instrument has positive
zero error as shown in Fig. 10 (b) and the correction is negative.

Negative zero error


When the circular scale is below the linear scale, the instrument has negative zero error
as shown in Fig. 10(c) and the correction is positive.

20
Experiment 1

Introduction to Error Analysis


and Graph Drawing

1.1 Finding τ and initial voltage across capacitor


You are given below the voltage decay as function of time across a capacitor in a RC
circuit.

1. Obtain the value of characteristic decay time constant by plotting the data in a
semi–logarithmic paper.

2. Obtain the initial value of the voltage across the capacitor.

Time (s) Voltage (V)


6.2 5.53
8.7 4.89
10.0 4.58
12.5 4.04
16.3 3.35
18.4 3.05
22.5 2.45
25.0 2.16
28.5 1.85
32.9 1.44
38.8 1.09
42.0 0.92
47.8 0.70
52.0 0.56
55.4 0.47
62.5 0.33
67.2 0.26

Table 1.1: Data of voltage decay in a capacitor as a function of time.

21
The equation governing the relation between voltage and time for the capacitor is as given
below.

v = vo e−t/τ (1.1)
t/τ
log v = log vo − log e (1.2)
t
log v = log vo − log e (1.3)
τ
From log10 v vs t plot, the value of τ can be obtained.

1.2 Resonant Rings


In an experiment, paper rings of different diameter are mounted on a vibrating table to
study their resonant frequencies. Depending on the diameter, the rings show resonant
vibration for different frequencies of the vibrating table. The data from this experiment
is given in Table 1.2. Use the formula F = CDn .

Diameter of the ring (cm) 3.4 4.6 6.4 8.7 10.9 13.2
Resonant frequency (Hz) 63.48 30.77 13.38 6.24 3.58 2.19

Table 1.2: Data of resonant frequencies as a function of diameter of the rings

1. Plot resonant frequency vs diameter of the ring in a log-log graph to obtain the
mathematical relationship between the two variables.

2. From your graph predict the resonant frequency for a ring of diameter 16 cm.

1.3 Mass Spring System


A spring (of mass 50 g) is suspended vertically. It is pulled slightly downward and time
for 20 free oscillations is observed. Repeat the observations for three times. Calculate the
average time period of this spring system. Now, using the equation, given below, calculate
the force constant k of the spring, to two decimal places.
s
mo + (ms /3)
T = 2π (1.4)
k

where mo is mass of weight hanged and ms is the mass of the spring.

Observation table

Sl. T20 Mean T20 T k


– (sec) (sec) (sec) (N/m)
1
2

Table 1.3: Table to calculate the spring constant of a spring.

22
From the Eq. (1.4) the error in calculating k is obtained as follows. If m0 = 0, then
squaring Eq. (1.4) and re-arranging the terms we have,

4π 2 ms
 
k=
3 T2

Taking log on both sides,


!
4π 2
log k = log + log ms − 2 log T
3

Taking derivative on both sides,

∆k ∆ms ∆T
 
= +2 (1.5)
k ms T
where we have changed the sign of in front of ∆T to calculate the maximum error.

1.4 Resistivity of a nichrome wire


A homogeneous nichrome wire along with a digitial multimeter and a screw gauge is given
to you.

1. Measure the resistance of the nichrome wire for three different lengths of the wire.

2. Use the screw gauge to determine the diameter of the wire.

3. Determine resistivity of the nichrome wire from your measurements using the formula

Rπd2 /4
ρ= , (1.6)
L

where, R = resistance of the nichrome wire,


d = diameter of the nichrome wire,
L = length of the nichrome wire. (1.7)

∆ρ ∆R
4. From Eq. (1.6) one can obtain ρ = R + 2 ∆d
d +
∆L
L and finally obtain ∆ρ for this
experiment.

Observation table
Total number of circular scale (CS) divisions of the screw gauge = . . . . . .
One main scale division (MSD) = . . . . . . cm
Number of rotations required on the CS to cover 1 MSD = . . . . . .
Zero error on the CS = . . . . . .
Least count (l.c) of the screw gauge

One main scale division (1 MSD)


l.c = cm (1.8)
No. of rotations on the CS × Total number of CS divisions

23
Sl. No. MSR (a) CSR (b) Total (a + b × l.c) (cm)
1
2

Table 1.4: Table to calculate the diameter of the nichrome wire

Sl. L (cm) Resistance (Ω) ρ (Ω m)


1
2

Table 1.5: Table to calculate the resistivity of the wire

1.5 To measure the electrical resistance of a given material


The resistance of the wire is measured with the help of a Wheatstone bridge up to the
accuracy of three significant figures. By using the relation.
P R
= (1.9)
Q S
where S is a variable resistor and R is an unknown resistor. If the ratio of the two known
resistances P/Q is equal to the ratio of the two unknown resistances R/S, then the voltage
difference between the points A and B will be zero and no current would flow through the
galvanometer G. In case there is a voltage difference between points A and B, direction
of the current in the galvanometer indicates the direction of flow of current through the
bridge. In this manager an unknown resistance R can be calculated to an accuracy of high
degree. Fig. 1.2 shows the experimental setup of a wheatstone bridge.

Observation table(No. of readings: 2 with different lengths)

Sl. No. 1000 100 10 1 Multiplier R (Ω)


(Ω) (a) (Ω) (b) (Ω) (c) (Ω) (d) (m)
1 1
2 0.1
3 0.01
4 0.001

where R = m × (a × 1000 + b × 100 + c × 10 + d × 1) Ω. The value obtained on the bottom


right most cell in the above table is your final answer to an accuracy of 0.001Ω. The final
answer is NOT the average of all the R values. Why?

24
Figure 1.1: A wheatstone bridge.

Figure 1.2: A wheatstone bridge setup.

25
Experiment 2

Acceleration due to gravity by bar


pendulum

Purpose
To determine the value of acceleration due to gravity using angular oscillations of a long
bar.

Apparatus
Stop watch, metallic bar of suitable length, meter scale, knife edge.

Theory
The purpose of this experiment is to use angular oscillations of rigid body in the form of a
long bar for determining the acceleration due to gravity. The particular form of the body
is chosen for the sake of simplicity in performing the experiment. The bar is hung from a
knife-edge through one of the many holes along the length. It is free to oscillate about the
knife-edge as axis. Any displacement θ, from the vertical position of equilibrium would
give rise to an oscillatory motion just as in the case of a simple pendulum. The difference
is that since this is rotating rigid body here we consider the torque of the gravitational
force giving rise to the angular acceleration.
The restoring torque τ for an angular displacement θ is
τ = −M gd sin θ (2.1)
where M is the mass of the compound pendulum and d the distance between the point of
suspension O and the centre of mass of the bar C.
Since τ is proportional to sin θ, rather than θ, the condition for simple angular harmonic
motion does not, in general, hold here. For small angular displacements, however, the
relation sin θ ≈ θ is a good approximation, so that for small amplitudes in turn for small
values of θ.
d2 θ
τ = −M gdθ = I (2.2)
dt2
where I is the moment of inertia of the bar about the point of suspension O. The solution
of the above equation is given by
θ(t) = A sin(ωt + φ) (2.3)
s
2π M gd
where, ω = = (2.4)
T I

26
is the angular velocity of the compound pendulum. Thus, the period of oscillation is given
by
s
I
T = 2π (2.5)
M gd

Due to the parallel axis theorem we have

I = I0 + M d2 , (2.6)

where, I0 is the moment of inertia of the pendulum about it’s center of gravity (C.G).
Inserting Eq. (2.6) in Eq. (2.5), we get the complete d dependence of the time period
T as
s
I0 + M d2
T = 2π (2.7)
M gd

Since I0 can be expressed as M k 2 , where k is the radius of gyration, Eq. (2.7) can be
rewritten as
s s
M k 2 + M d2 k 2 + d2
T = 2π = 2π . (2.8)
M gd gd

A simple pendulum consists of a mass m hanging at the end of a string of length L.


The time period of a simple pendulum is given by
q
T = 2π L/g . (2.9)

So, the time period of a simple pendulum equals the time period of a compound pendulum
when
d2 + k 2
L= (2.10)
d
Re-arranging the above equation

d2 − Ld + k 2 = 0 (2.11)

gives us a quadratic equation in d. If d1 and d2 are the two solutions of the above equation,
then we find

d1 + d2 = L (2.12)
d1 d2 = k (2.13)

Since both d1 and d2 are positive, we conclude that there are two point of suspensions
on one side of the C.G. of the compound pendulum where the time periods are equal.
Similarly, there are two points of suspension on the other side of the C.G where the time
periods are same. Thus, for a compound pendulum, there are four points of suspension,
two on either side of the C.G. where the time periods are equal. The simple equivalent
length L is sum of two of these point of suspension located asymmetrically on two sides
of the C.G.
To facilitate further analysis it is useful to square Eq. (2.7) to get
!
2 2 I0 + M d2
T = 4π (2.14)
M gd

27
In order to gain insight in the dependence of T on d let us first look at the dependence
for (i) small d and (ii) large d. For small d (specifically for M d2  I0 ) we have

I0
T 2 ∼ 4π 2 (2.15)
M gd
1
T ∼ √ . (2.16)
d
Thus T decreases as d increases. In the opposite limit i.e. for large d (specifically for
M d2  I0 ) we have

M d2
T 2 ∼ 4π 2 (2.17)
M gd

T ∼ d (2.18)

Thus T increases as d increases in this case. Physically the origins of d2 in the numerator
is coming from the expression for the moment of inertia I ∼ d2 .
It is then just a question of which effect dominates for a given values of d. To under-
stand this better (or more quantitatively) let us looks at the turning point. The minimum
of the expression for T 2 as a function of d can be determined by taking the taking deriva-
tive of T 2 with respect to d and setting it equal to zero (and ensuring the sign of the
second derivative term corresponds to a minimum). Following this procedure gives
s
I0
d= (2.19)
M

Eq. (2.19) can be written as I0 = M d2 . This relation is satisfied at the minimum or at


the turning point. Using this in Eq. (2.7) we find that the turning point occurs when
the magnitude of the two terms of the numerator are equal. For M d2  I0 the I0
term dominates in the numerator and d dependence is given by the denominator. In the
region M d2  I0 the M d2 term dominates in the numerator and so the d dependence is
dominated by the numerator.

History of the experiment


Galileo was the first person to show that at any given place, all bodies fall freely when
dropped, with the same (uniform) acceleration, if the resistance due to air is negligible.
The gravitational attraction of a body towards the center of the earth results in the same
acceleration for all bodies at a particular location, irrespective of their mass, shape or
material, and this acceleration is called the acceleration due to gravity, g. The value of
g varies from place to place, being greatest at the poles and the least at the equator.
However, direct measurement of the acceleration due to gravity is very difficult.
Therefore, the acceleration due to gravity is often determined by indirect methods, for
example, using a simple pendulum or a compound pendulum. If we determine g using
a simple pendulum, the result is not very accurate because an ideal simple pendulum
cannot be realized under laboratory conditions. Hence, a compound pendulum is used to
determine the acceleration due to gravity in the laboratory.

Procedure
• Balance the bar on sharp wedge and mark the position of its center of gravity (C.G.).

• Ensure that the frame on which movable knife edge / pivot is to be rested is hori-
zontal.

28
Figure 2.1: Image of a bar pendulum

Sl. d No. of oscillations Mean T10 T


1 2 3
– (cm) (sec) (sec) (sec) (sec) (sec)

.. .. .. .. .. .. ..
. . . . . . .

Table 2.1: Table to measure acceleration due to gravity via a compound pendulum.

Figure 2.2: Pivot or knife edge of the bar pendulum

• Suspend the pendulum in the first hole. The knife edge or pivot should be placed
on the glass plate as shown in Fig. 2.2.

29
• The distance d is the distance between point of suspension (bottom of the hole) and
the C.G.

• Start the oscillation of the pendulum.

• Use the stop watch to measure the time for 10 oscillations. The time should be
measured after the pendulum has had a few oscillations and the oscillations have
become regular.

• Repeat the process by suspending the pendulum in the consecutive holes.

• Draw a graph by taking distance along X-axis and time period along Y -axis as
shown in Fig. 2.3. Shift the axes to draw a full page graph.

Figure 2.3: Plot of time vs distance from center of gravity of bar

Calculation
1. With the help of the graph, distance d1 and d2 can be measured from which the
value of g can be calculated by using formulas

d1 + d2 = L (2.20)
4π 2 L
g = (2.21)
T2
where d1 and d2 the distances M1 A1 , M1 B1 respectively and T is the time CM1 as
shown in Fig. 2.3. As there are two branches one could take the mean of Q1 M1
and M1 A1 for the distance d1 and mean of P1 M1 and M1 B1 for the distance d2 for
substitution in this formula.

2. Choose another line P2 B2 and find g2 using Eqns. (2.20) and (2.21), where d1 is the
mean of Q2 M2 and M2 A2 , d2 is the mean of P2 M2 and M2 B2 and T = CM2 .

30
3. At the minima, ensure that P3 M3 is equal to M3 B3 . Then calculate g3 via the
formula
P3 B3
g = 4π 2 (2.22)
CM32

4. Find the average value of g.

Theoretical error
Acceleration due to gravity (g) is given by the formula

4π 2 L
g= (2.23)
T2
Taking log and differentiating
∂g ∂L ∂T
= +2 (2.24)
g L T
Thus, maximum possible error = ................%.

Results
• The standard value of g = ..............m/sec2 .

• Percentage error = ...............%.

Precaution
1. The Knife edge is made horizontal. If it is not perfectly horizontal the bar may be
twisted while swinging.

2. The motion of a bar should be strictly in a vertical plane.

3. The amplitude of the swing should be small.

4. The time period of oscillations should be determined by measuring time by large


number of oscillations with an accurate stop watch.

5. All distances should be measured and plotted from one end of the rod.

31
Experiment 3

Helmholtz coil

Purpose
To study the magnetic field produced by current carrying coils.

Apparatus
Helmholtz coils, connecting wires, gaussmeter, regulated power supply, measuring scale,
etc.

Theory

Figure 3.1: Magnetic field perpen- Figure 3.2: Helmholtz coil.


dicular to a current carrying coil.

The magnetic induction of a circular coil of radius R, carrying a current I, at a distance


z from the center of the loop along the axis (see Fig. 3.1) is given by

~ µo I R2
B(z) = k̂ (3.1)
2 (R2 + z 2 )3/2

~
where µ0 is the permeability of free space. At z = 0, B(0) = µo I/(2R) ≡ B10 .
If there are two such parallel coils at a distance S such that the current flows in the
same direction in both the coils (see Fig. 3.2), then magnetic field adds in the space

32
between them. Then we have
 

~ µo IR2  1 1 
B(z) = 2 3/2 +  (3.2)
 
2

   2 3/2 
 
S S
(R2 + 2 +z (R2 + 2 −z
 
1 1
= B10  h i3/2 + h (3.3)
 
2 3/2
i 
2
(1 + (0.5 st + zt) (1 + (0.5 st − zt)

where, st = S/R, zt = z/R and B10 = µo I/(2R).


~
At the midpoint ∂ B/∂z ~
is zero. Further ∂ 2 B/∂z 2 is also equal to zero at z = 0 if

S = R. Because of these properties, the axial magnetic field is fairly constant over certain
region in the middle of the pair of coils. This arrangement is very popular in producing
uniform axial fields in regions easily accessible to experimental situations needing such
uniformity.
In this experiment we will study the magnetic field variations for such a pair of
Helmholtz coils. The magnetic field is measured using a Hall probe connected to a gauss-
meter.

Construction of Helmholtz coils


The two coils are made of copper wire windings in 14 layers, each of 11 turns, such that the
total number of turns (n) = 154. The sockets of the coil winding are cast into the plastic
foot of the coil and the connecting leads can be used to connect the coils in parallel or
series as required. The sockets are numbered (1, 2) to make it easier to wire the coils. See
Fig. 3.3. In the Helmholtz arrangement, the coils are positioned by three spacer rails so

Figure 3.3: Experimental setup of Helmholtz coil.

that their axial spacing is equal to the average coil radius. The rails can be removed after
undoing knurled screws, allowing coils to be used individually or with variable spacing.

33
The coil of the diameter 400 mm
No of turns per coil 154
Coil resistance 2.1 Ω

Procedure
• Calibrate the Hall probe attached to the gaussmeter.
• Connect the coils with the power supply in such a way that both the coils have the
same current in proper direction. In no case the current should exceed 3A.
• Place the hall probe perpendicular to the magnetic field and measure the readings
at regular intervals.

Observation
We study the magnetic field in current carrying coil (Helmholtz coil) in three different
scenarios:

(A) Magnetic field along the axis of the coils when current is flowing in
the same direction in both the coils
Sl. Distance (cm) Magnetic field (Gauss)
I1 = . . . A I2 = . . . A

(B) Magnetic field along the axis in a single coil

Sl. Distance (cm) Magnetic field (Gauss)


I1 = . . . A I2 = . . . A

(C) Magnetic field along the diameter in a single coil

Sl. Distance (cm) Magnetic field (Gauss)


I1 = . . . A I2 = . . . A

Plot the intensity of magnetic field with distance along the coil for different current value
for above describe three case.

Results
1.
2.

34
Experiment 4

Measurement of band gap of


semiconductor

Purpose
• Measurement of resistivity of a semiconductor at room temperature

• Measurement of variation of resistivity with temperature.

• Evaluation of band gap of the given semiconductor from the plotting of acquired
data.

• Understanding of the concept of four probe method.

Apparatus
Four probe experimental setup.

Theory
Semiconductor
Semiconductor is a very important class of materials because of wide applications in this
modern world. The following are the properties which gives a rough description of a
semiconductor.

1. The electrical conductivity of a semiconductor is generally intermediate in magnitude


between that of a conductor and an insulator. That means conductivity is roughly
in the range of 103 to 10−8 siemens per centimeter.

2. The electrical conductivity of a semiconductor varies widely with doping concentra-


tion, temperature and carrier injection.

3. Semiconductors have two types of charge carriers, electrons and holes.

4. Unlike metals, the number of charge carriers in semiconductors largely varies with
temperature.

5. Generally, in case of semiconductor, increase of temperature enhances conductivity


while in case of metals increase of temperature reduces conductivity.

6. The semiconductor can be best understood in the light of energy band model of
solid.

35
Figure 4.1: Band gaps shown for (a) Insulator (b) Alkali Metal (c) Other Metal (d) Ge-
semiconductor

Energy band structure of solid


Atom has discrete energy levels. When atoms are arranged in a periodic arrangement in
a solid the relatively outer shell electrons no longer remain in a specific discrete energy
level. Rather they form a continuous energy level, called energy band. In case of semicon-
ductor and insulator, at temperature 0K all the energy levels up to a certain energy band,
called valence band, are completely filled with electrons, while next upper band (called
conduction band) remains completely empty. The gap between bottom of the conduction
band and top of the valence band is called fundamental energy band gap (Eg ), which is
a forbidden gap for electronic energy states. In case of metals, valence band is either
partially occupied by electrons or valence band has an overlap with conduction band, as
shown in Fig. 4.1(b and c).
In case of semiconductor, the band gap (∼ 0 − 4eV ) is such that electrons can move
from valence band to conduction band by absorbing thermal energy. When electron moves
from valence band (VB) to conduction band (CB), it leaves behind a vacant state in
valence band, called hole. When electric field is applied, movement of large number of
electrons in the valence band can be visualized by the movement of hole as a positive
charge particle. The Eg is a very important characteristic property of semiconductor which
dictates it’s electrical, optical and optoelectrical properties. There are two main types of

Figure 4.2: Energy band diagram of a semiconductor

semiconductor materials: intrinsic and extrinsic. Intrinsic semiconductor doesn’t contain


impurity. Extrinsic semiconductors are doped with impurities. These discrete impurity
energy levels lie in the forbidden gap. In p-type semiconductor, acceptor impurity, which
can accept an electron, lies close to the valence band and in n-type semiconductor, donor

36
Figure 4.3: Temperature variation of carrier concentration

impurity, which can donate an electron lies close to conduction band.

Temperature variation of carrier concentration


Fig. 4.3 shows the variation of carrier concentration (concentration of holes) in a p-
type semiconductor with respect to 1000/T , where T is the temperature. Initially as
temperature increases from 0K (i.e. ionization region), the discrete impurity vacant states
starts getting filled up from valence band, which creates holes in valence band. Beyond a
certain temperature all the impurity states will be filled up with electrons, which lead to
the saturation region.
As temperature increases to further higher values, electrons, in the valence band, get
sufficient energy to occupy empty states of conduction band (C.B). This region is called
intrinsic region. The temperature above which the semiconductor behaves like intrinsic
semiconductor is called “Intrinsic temperature”.

Conductivity of a semiconductor
The conductivity of a semiconductor is given by

σ = e(µn n + µp p) (4.1)

Where µn and µp refer to the mobilities of the electrons and holes, and n and p refer to
the density of electrons and holes, respectively. The mobility is drift velocity per electric
field applied across the material, µ = Vd /E. Mobility of a charge carrier can get affected
by different scattering processes.

Effects of temperature on conductivity of a semiconductor


In the semiconductor, both mobility and carrier concentration are temperature dependent.
So conductivity as a function of temperature can be expressed by

σ = e (µn (T )n(T ) + µp (T )p(T )) (4.2)

One interesting special case is when temperature is above intrinsic temperature where mo-
bility is dominated by only lattice scattering (∝ T −3/2 ). That means in this temperature
region mobility decreases with increase of temperature as T −3/2 due to increase of thermal
vibration of atoms in a solid.

37
In the intrinsic region, n ≈ p ≈ ni , where ni is the intrinsic carrier concentration. The
intrinsic carrier concentration is given by
3/2
2πkT −Eg
  
ni (T ) = 2 (m∗n m∗p )3/4 exp , (4.3)
h2 2kT
where, m∗n and m∗p are effective mass of electron and hole. Here the exponential temper-
ature dependence dominates ni (T ). The conductivity can easily be shown to vary with
temperature as
−Eg
 
σ ∝ exp . (4.4)
2kT
In this case, conductivity depends only on the semiconductor band gap and the tempera-
ture. In this temperature range, plot of ln σ vs 1000/T is a straight line. From the slope
of the straight line, the band gap (Eg ) can be determined. The procedure of measurement
of conductivity is given below.

Four probe technique


Four probe technique is generally used for the measurement of resistivity of semiconduc-
tor sample. Before we introduce four probe technique, it is important to know two probe
techniques by which you measured resistivity of a nicrome wire. In two probe technique,
two probes (wires) are connected to a sample to supply constant current and measure
voltage. In the case of nicrome wire (1st experiment), connections are made by pressing
the multimeter probes on nichrome wire. The contact between metal to metal probe of
multimeter does not create appreciable contact resistance. But in the case of semiconduc-
tor the metal – semiconductor contact gives rise to high contact resistance. If two probe
configuration is followed for semiconductor sample, voltmeter measures the potential drop
across the resistance of the sample as well as the contact resistance. This is shown in the
Fig. 4.4(a).
The potential drop across high contact resistance can be avoided by using four probe
technique. In the four probe configuration, two outer probes are used to supply current
and two inner probes are used to measure potential difference. When a digital voltmeter
with very high impedance is connected to the inner two probes, almost no current goes
through the voltmeter. So, the potential drop it measures, is only the potential drop
across the sample resistance. This is shown in the equivalent circuit diagram given in
Fig. 4.4(b). From the measurement of current supplied and voltage drop across the sample,
the resistance can be found out. Resistivity of a sample is given by ρ = cV /I, where c is
a constant.
For the specific arrangement, where the probes are equispaced with the distance be-
tween two successive probes as a, and the thickness of the sample is h, the resistivity can
be calculated by the following formulas.
Case I: h  a. In this case it is assumed that the four probes are far from the edge of the
sample and the sample is placed on an insulating material to avoid leakage current.
The resistivity in this case is given by
V
ρ = 2πa (4.5)
I
This is the setup used for our experiment.
Case II: h  a. In this case the resistivity is given by
πh V
 
ρ= (4.6)
ln 2 I
Derivation for this is given at the end.

38
Figure 4.4: (a) Equivalent circuit for two probe measurement. R1 , R2 are the contact
resistances (b) Equivalent circuit for four probe measurement. R1 , R2 and R3 , R4 are the
contact resistances of current and voltage probes.

Once resistivity (ρ) is determined, conductivity (σ) can be calculated by taking recip-
rocal of it (σ = 1/ρ).

Advantages of using four probe method


• The key advantage of four-terminal sensing is that the separation of current and
voltage electrodes eliminates the impedance contribution of the wiring and contact
resistances.

• If the probes are separated by equal distance a, and a  h then resistivity can be
found out without knowing the exact shape and size of the sample.

Figure 4.5: Pictorial representations of field lines generated by the applied potential.

39
Description of the experimental set-up
Probes arrangement It has four individually spring loaded probes. The probes are
collinear and equally spaced. The probes are mounted in a teflon bush, which ensure
a good electrical insulation between the probes. A teflon spacer near the tips is also
provided to keep the probes at equal distance. The whole arrangement is mounted
on a suitable stand and leads are provided for the voltage measurement.

Sample Germanium crystal in the form of a chip.

Oven It is a small oven for the variation of temperature of the crystal from the room
temperature to about 200o C (max).

Figure 4.6: Four probe experimental setup.

Procedure
• Switch ON the band gap setup.

• Supply current to the crystal and keep it constant (3 mA) throughout the experiment.

• Initially the temperature of the oven must be at room temperature (∼ 27o C).

• Switch on the oven to start increasing the temperature.

• Note the voltage and temperature at intervals of 5o C starting from room temperature
till 140o C.

• Find the mean of the two voltages, for increasing and decreasing temperatures.
Calculate ρ for each temperature.

• Convert the temperature scale from 0 C to the Kelvin scale (K). The plot of ln σ vs
1/T should be a straight line. Calculate the slope (m) of the straight line and finally
the band gap Eg from the given formula

Eg
 
σ = σo exp − (4.7)
2KT

40
Observations
Sl. Temp (T) 1000/T I during inc. Inc. volt. Inc. V/I ρ σ = 1/ρ ln σ
temp.
(o C) (K−1 ) (I) (mA) (V) (mV) (Ω) (Ω m) (S m−1 ) −−

Results
1.

2.
41
Experiment 5

Refractive index of glass with the


help of a prism

Purpose
• To understand the accurate leveling and focusing of a spectrometer.

• Investigation of the variation in the refractive index, µ of a prism with wavelength


λ.

Apparatus
Spectrometer, prism, mercury light source, high voltage power supply, magnifying lens,
spirit level, torch light etc.

Theory
The fact that a prism is capable of dispersing light is due to the variation of its refractive
index with wavelength. In this experiment the refractive index is obtained for a variety of
wavelengths by measuring the minimum deviation angle of the prism for each wavelength.
To understand what is meant by the term angle of minimum deviation, consider Fig.
5.1. The incident parallel light beam is refracted by the prism in such a way that it is
deviated by the angle θd from the undeviated direction. The angle is known as the angle
of deviation and varies with both the wavelength and the angle at which the incident light
intersects the prism.
If the prism is rotated about the axis it is found that the angle of deviation changes but
never becomes less than a certain minimum value, δmin known as the angle of minimum
deviation i.e. no matter what the orientation of the prism, as long as it is in the path of the
incident light beam, the light beam will be deviated through at least this angle. When the
prism is oriented in such a way that the exit beam is deviated through the least possible
angle δmin , then further rotation of the prism in either direction will cause the exit beam
to move further away from the least deviated direction. Thus for each wavelength in a
spectral light source, there is a variation of the angle of deviation, θd with the angle of
incidence, θi and at some value of the angle of incidence, the angle of deviation reaches a
minimum as seen in Fig. (5.3).

Relation between µ and λ


The refractive index of the prism material, µ is a function of the angle of minimum
deviation (δmin ), the incident wavelength (λ) and the prism refracting angle (A). Thus,

42
Figure 5.1: Deviation of monochromatic Figure 5.2: Spectrum due to a prism.
light ray due to prism.

Figure 5.3: Variation of the angle of deviation (θd ) with the angle of incidence (θi ) for a
particular wavelength.

by measuring δmin for a variety of wavelengths, the variation of µ with wavelength may
be determined.
To derive the exact relationship, consider the prism as seen in Fig. (5.4). It can be
shown that the minimum value of the angle of deviation, δmin occurs when the ray passes
through the prism symmetrically i.e. when the angle at which the light emerges is equal
to the angle of incidence such that the ray passes parallel to the base of the prism as in
Fig. (5.4). At each face the ray changes direction by θi − θr and so the total minimum
deviation is

δmin = 2(θi − θr ) (5.1)

From Fig. 5.4, it is shown that the angle 6 M N O is the same as that of the refracting
angle of the prism. Referring to the triangle LMN it is obvious, using trigonometry, that
A = 2θr . Snell’s Law is of course µ = sin θi / sin θr but θi = δmin /2 + θr , where θr = A/2
and hence we have
sin ((A + δmin )/2)
µ= . (5.2)
sin(A/2)
An empirical equation of the form
b c
µ = a+ + (5.3)
λ2 λ4

43
Figure 5.4: Condition for minimum deviation

was developed by Cauchy to describe the variation of µ with wavelength. Where a, b and
c are constants and it is the purpose of this experiment to verify this equation (neglecting
terms of higher order than the second) and to derive the constants a and b for the prism
material.
Note: As the variation in refractive index over the whole of the visible is only of
the order of 3% this means that δmin varies only very slowly with wavelength. Both a
fair degree of experimental skill and great care in making the various measurements are
necessary if reasonable results are to be attained.

Experimental procedure
Initially make sure you understand what each component of the spectrometer as detailed in
Fig. (5.5)Spectrometer
The Prism does. The experimental setup consists of following parts. To obtain satisfactory
Page 4 of 8

Figure 4: Schematic diagram of the prism spectrometer.


Figure 5.5: Spectrometer with its components

results the spectroscope requires some initial adjustments before the desired measure-
In this
ments can experiment, we will
be performed. For use
thisaexperiment
prism spectrometer
great careto must
measure
be the deviations
taken of light
in adjusting the
for various wavelength. The spectrometer is an instrument for studying optical spectra. A
schematic diagram of a prism spectrometer is shown in Figure 4. It consists of a collimator, a
telescope, a prism and a circular spectrometer44table. The collimator holds an aperture at one
end that limits the light coming from the source to a narrow rectangular slit. A lens at the
other end focuses the image of the slit onto the face of the prism. The telescope magnifies the
light exiting the prism and focusses it onto the eyepiece. The prism, of course, disperses the
spectrometer so that the telescope is focused at infinity and the collimator set to give an
accurately parallel beam. It is particularly important to ensure that the cross-hairs of the
telescope are sharply visible and that no parallax exists between them and the spectral
line images. The following steps should ensure this:

1. Focusing the telescope: Focus the telescope for the parallel rays from the distance
object by sliding the eyepiece looking through telescope in and out, until a sharp
image of object is seen. Due to the location of the laboratory this may not be possible
so the building opposite may be used for this purpose.

2. Levelling the collimator: Place the spirit level on the collimator tube with its axis
parallel to the axis of the tube. If the the bubble in the collimator is found to
be displaced from its central position, turn the levelling screws provided with the
collimator tube, in the same direction to bring the bubble back to its central position.
This make the axis of the collimator tube horizontal.

3. Levelling of the prism table: There are three levelling screws A, B, C just below
the prism table for levelling the table. There are parallel lines drawn on the prism
table parallel to the line joining the screws B and C. Place the spirit level parallel
to these lines and bring the bubble to the central position by turning the screws B
and C equally in opposite directions. Now place the spirit level perpendicular to the
line BC. If the bubble is not in the central position, then turn the A screw alone to
bring the bubble in the center. Continue this for a couple of times until the bubble
is in the center in both the positions. This makes the table vertical to the axis of
rotation.

4. Focusing the collimator: Place a discharge lamp (Mercury lamp as a visible light
source) in front of the spectroscope and turn the telescope until it is in line with and
pointing directly at the collimator. Looking through the telescope and adjusting the
position of the focusing screw on the collimeter until a sharp image of the slit is
observed in the telescope. The collimeter now gives parallel rays which will fall on
the prism.

Finding the least count for the spectrometer


It should be noted by the student that 30 vernier scale divisions (VSD) coincides with 29
circular scale divisions (CSD). So,

30 VSD = 29 CSD (5.4)


29
1 VSD = CSD (5.5)
30

Therefore, the least count

LC = 1 CSD − 1 VSD (5.6)


29 1
 
= 1− CSD = CSD (5.7)
30 30

Since 1 CSD = (1/2)◦ = 300 , we have

1
LC = × 300 = 10 (5.8)
30

45
Figure 5.6: Measurement of the reflecting angle of prism.

Measurement of the angle of prism (A)


• Set up the prism and spectrometer as in Fig. (5.6). Lock the prism table.

• Place the telescope cross-hairs in turn on the image of the slit reflected from surface
AB and then surface AC.

• At each position record the angular position of the telescope on the vernier scale-
the angle between the two positions of the telescope is 2A, twice the apex angle of
the prism and hence A can be found.

• Repeat above step 2 and 3 to get an average value for A(≈ 60o ).

Viewing the spectrum due to refraction


The telescope and prism are rotated until the spectrum formed by refraction is found.
The approximate prism position is shown in Fig. 5.7.
Further rotation of the prism while viewing the spectrum through the telescope will
result in reaching the angle of minimum deviation. This is where the spectral lines “turn
back" on themselves i.e. move opposite to their initial direction of travel while the prism
is still being rotated in the same direction.
Position the prism and telescope so that the spectral lines are at the angle of minimum
deviation i.e. at the point where the spectral lines “turn back" on themselves.
Turning the prism towards the telescope, increases the angle of incidence, thus moving
to the right hand side of δmin in the curve of Fig. (5.3). Conversely turning the prism
towards the collimator, decreases the angle of incidence, hence moving through the angle
of minimum deviation to the left hand side of the curve of Fig. 5.3.

Measurement of the angle of minimum deviation, δmin for each wavelength


1. Using the Hg spectral lamp, observe the first order field of view of refracted spec-
trum. Find the point of minimum deviation for the Hg spectrum. The approximate
prism position is as shown in Fig. 5.7.

46
Figure 5.7: Prism position for viewing the spectrum due to refraction.

Lamp Colour Wavelength


(nm)
Violet 380 - 450
Blue 450 - 495
Mercury Green 495 - 570
Yellow 570 - 590
Orange 590 - 620
Red 620 - 750
Yellow (D1 ) 589.6
Sodium
Yellow (D2 ) 589.0

Table 5.1: Discharge lamp wavelengths

(Remember minimum deviation corresponds to the point at which movement of the


lines of the Hg spectrum over the field of view of the telescope is reversed, although
direction of rotation of the telescope continues in the same sense.)

2. Several spectral lines should be in the field of view of the telescope. Position the
telescope on the highest wavelength spectral line and lock the prism table and tele-
scope. It is essential that the prism and prism table remain in this position for the
remainder of the experiment.

3. Using the telescope fine adjustment screw, position the crosshairs of the telescope
accurately on the spectral line of interest and read the vernier to the nearest minute
of arc.

4. The above step can be repeated for the other lines in the field of view of the telescope
there should be enough movement in the telescope fine adjustment screw to allow

47
positioning of the cross-hairs on all of the Hg spectral lines of Table 5.1 without
unlocking the telescope again. If this is not the case, just unlock the telescope
and reposition it such that the crosshairs of the eyepiece are on the spectral line of
interest. It is imperative that the prism and prism table remain in their original
fixed position.

5. Rotate the telescope anticlockwise until the undeviated image of the slit through the
prism is in the field of view. Again position the crosshairs on the centre of the clit
image and record the angular reading of the telescope on the vernier scale.

6. The actual value for δmin for each wavelength is the difference between the appro-
priate angular reading of the telescope position for minimum deviation and for the
undeviated (straight through) position as seen in Fig. (5.1)

Observation
Measurement of angle of prism (A)
Least count of the spectrometer (l.c.) = ..............

Sl. Position I Position II 2A =


θ1 − θ2 Prism

CSR VSR Total CSR VSR Total angle


reading reading (A)
(θ1 ) (θ2 )

– (deg) – (deg) (deg) – (deg) (deg) (deg)

Table 5.2: Table for measuring angle of prism (A). CSR - Circular scale reading, VSR -
Vernier scale reading.

Measurement of angle of minimum deviation (δmin )


Angle by undeviated ray (θ0 ) = . . . . . . (CSR) + . . . . . . (l.c) × . . . . . . (VSR) = . . . . . . (Total)

Calculation
1. Calculate the refractive index µ, of the prism material for each wavelength using Eq.
5.2. Tabulate also a corresponding set of values for 1/λ2 .

2. Draw a graph of µ vs 1/λ2 .

3. Extract values for the Cauchy constants, a (intercept) and b (slope), of Eq. 5.3 from
your graph. The least squares fitting routine can be used to get a more accurate
value for a and b.

Results
• Calculate the refractive index for different values of wavelengths.

48
Sl. Colour Angle by deviated ray δmin = θ0 −θ µ

CSR VSR θ

– – (deg) – (deg) (deg) –

1 Violet

2 Green

3 Yellow

4 Red

Table 5.3: Table for measuring angle of minimum deviation. CSR - Circular scale reading,
VSR - Vernier scale reading.

Notes
Subtraction of angles (Mathematical)
0 0
Try to substract 45◦ 25 from 90◦ 15 . (Hint: Remember that 1◦ = 600 ).

Note about calculators


• Some calculators are not able to handle degree and minutes. Make sure the degree
minutes in these cases are converted to fractional degree via the conversion 1◦ = 600 .

• Make sure your calculator is set to degree and not to radian or gradient.

Subtraction of angles (Geometrical)


Find the difference of angles ∆ for these cases

• θ1 = 100◦ , θ2 = 10

• θ1 = 100◦ , θ2 = 350

(Hint: If the difference between two angles (∆) is more than 180◦ , subtract ∆ from 360◦ .
See Fig. 5.8.)

49
(a) (b)

Figure 5.8: Difference of angles in the two cases should be as follows: (a) ∆ = |θ2 − θ1 |
and (b) ∆ = (360 − θ1 ) + θ2 = 360 − (θ1 − θ2 ).

50
Experiment 6

Wavelength of sodium light by


Newton’s rings

Purpose
To determine the wavelength of sodium light by measuring the diameters of Newton’s
rings

Apparatus
Newton’s ring microscope, sodium vapour lamp, circular slit plate, light emitting diode
source

Theory
Fig. 6.1 shows the experimental setup of Newton’s ring. The formation of maximum inten-
sities at some points and minimum intensities at the other due to the superposition of two
coherent light waves (of same frequencies and constant phase difference) is called interfer-
ence of light. The interference fringes are observed as an alternate pattern of bright and
dark fringes. The interference at a point where the intensity of light is maximum, is called
constructive interference (corresponds to bright fringe). For constructive interference, the
two waves should have either same phase or a constant phase difference of

φ = 2nπ , (6.1)

where n = 0, 1, 2, . . .. Phase difference (φ) and path difference (∆) are related by the
equation

φ = (2π/λ)∆ , (6.2)

where λ is the wavelength of the incident light. So, for constructive interference the path
difference between the light waves should be

∆ = nλ . (6.3)

The interference at other point where the intensity of light is minimum, is called destructive
interference (corresponds to dark fringe). For destructive interference, the two waves
should have either same phase or a constant phase difference of

φ = (2n + 1)π, (6.4)

51
where n = 0, 1, 2, . . . or a constant path difference of

∆ = (2n + 1)λ/2. (6.5)


Interference fringes are obtained by dividing the single coherent source into two sources.
This can be achieved by one of the following methods
1. by division of wave front, that is by taking (or considering) two secondary wavelets
on the same wave front and superposing them
2. by division of amplitude, that is by separating the amplitude of single wave and
reuniting them.
In the case of Newton’s ring interference is due to division of amplitude.

Figure 6.1: Experimental setup of Newton’s ring

When light is incident on a thin film (thickness of the order of wave length of the
incident light), it suffers partial reflection and partial transmission at both upper as well
as lower surfaces of the thin film. The transmitted light ray again suffers reflection at the
lower surface. Interference occurs between the rays in the reflected and transmitted parts.
Similarly, in a wedge-shaped film, partial reflection as well as partial transmission also
takes place. Moreover, the path difference changes from point to point which results into
an interference fringe.
Fig. 6.2 shows an wedge-shaped air film formed between the convex and plane glass
plate inclined at an angle say θ. The refractive index of the film is µ. Ray AB is inci-
dent from a broad monochromatic source almost normally on the film. It suffers partial
reflection (ray BE) and partial transmission (ray BC) on the convex surface. Ray BC
again suffers partial reflection (ray CF ) and partial transmission (not shown) on the plane
surface at C.
The bright rings in the Newton’s ring, as shown in Fig. 6.3, are due to constructive
interference between the reflected light rays BE and CF . The dark rings are caused by
destructive interference between the same light rays BE and CF .
For a wedge-shaped thin film, the path difference between the rays BE and CF is
given by
∆ = 2µt cos α (6.6)

52
microscope tube, with the help of coarse movement knob no. 2 and 4 as sho
bring it over the glass plate P’.
10 Now move the microscope tube with the help of fine movement knob no. 3
P’ to obtain clear image of surface. Slowly move towards upward directio
pattern is observed. Adjust by moving the microscope to and fro, if necessar
pattern. Adjust further for better contrast between bright and dark fringes as sho

11 Bring the cross-wire, using knob no.1 shown in figure 6, in the central dark f
Figure 6.2: Schematic diagram of the light rays Figure 6.3: Newton’s ring
centre should coincide with each other.
in Newton’s ring
12 Slide the cross-wire to the left till the vertical cross-wire line lies tangentiall
ring.
Where t is the thickness of the Note theBreading
film at on the
(or at D) andmain andangle
α is the circular scale using
of refraction at the
B. light emitting dio
Since the angle of incidence is almost normal, we can assume cos α ≈ 1. Note that here we
13 Now slowly slide the microscope to the right and note the reading when the
ignore the reflections from top of the plano-convex th th, 8bottom
th and 4ofththe
lies tangentially at the 16 lens
, 12and plane circular
dark rings respectively.
glass plate since these reflections just contribute to the overall glare. The reflections of
interest are only those 14 Keep sliding
involving the microscope
the surfaces in contact. to the right and again note the readings when the
th th, 12th, 16th and 20th dark rings respectively.
Now by Stoke’s law, there is no phase change4 at, 8
lies tangentially at the the glass-air interface of the convex
lens (because the wave is going from a higher to a lower refractive index medium), whereas
the reflection at the air-glass interface of the plane glass plate undergoes an additional path
difference of λ/2. Therefore, the net path difference is
Nvis Technologies λ Ltd. λ
∆ + Pvt.
= 2µt + (6.7)
2 2
Since for bright fringe, net path difference is nλ we have,
λ
2µt = (2n + 1) . (6.8)
2
Similarly, for dark fringe, the net path difference is (2n + 1)λ/2 and thus we have,
2µt = nλ . (6.9)
At the centre, no reflection occurs since the two glass surfaces are in intimate contact i.e.
t = 0 or 2µt = 0. This is the condition for dark fringe. Hence the center of the pattern is
always dark.
In the right-angled triangle OAB of Fig. 6.4,
OB 2 = OA2 + AB 2
or, R2 = (R − t)2 + rn2
or, rn2 = 2Rt (6.10)

for t2  2Rt. Thus,

t = rn2 /2R
or, t = Dn2 /8R (6.11)

where, rn = radius of nth ring,


Dn = diameter of the nth ring,
R = radius of curvature of the plano-convex lens.

53
Figure 6.4: Schematic diagram of plano- Figure 6.5: Newton’s ring assembly
convex lens

In practice, it is not possible to find the exact centre of the bull’s eye in order to
obtain rn . Rather, the traveling microscope can measure an approximate diameter Dn for
the interference ring. Therefore, substituting the value of t from Eq. 6.9, we obtain the
diameters of the nth dark fringe as
4nRλ
Dn2 = (6.12)
µ
Since the human eye is more sensitive to small changes in low intensity, we will measure
positions of dark fringes throughout the experiment.

Procedure
1. The Newton’s ring microscope has two parts, (i) microscope with horizontal mea-
surement and (ii) a Newton’s ring assembly. First detach the Newton’s ring assembly
and clean the adjustable glass plate, plano-convex lens and its adjoining glass plate
with a clean cloth.
Note: Do not detach the plano-convex lens from glass plate frequently. It will disturb
the measurements.

2. Replace the plano-convex lens over the glass plate and tight them carefully with
the help of three leveling screws (if present). An interference ring pattern can be
observed with the naked eye.
Precaution: Avoid over-tightening of the screws. Tight the screws to bring the
central fringe at the centre. Adjust it’s diameter to around 3 mm.

3. Arrange the Newton’s ring assembly as shown in Fig. 6.5. Note that the glass plate
P 0 should be inclined at 45◦ with respect to the vertical plain.

4. First connect the sodium vapour lamp power supply with mains. Then connect it
with the light source box with the help of mains cord. Then switch ON the power
supply.
Precaution: Never connect the sodium vapour lamp directly to the main power
supply.

5. Wait for 30 minutes till the lamp glow bright yellowish.

6. Insert circular slit plate into the slit-holder. Adjust to fully illuminate glass plate P 0
inclined at 45◦ .

54
7. Calculate the least count of the traveling microscope (M ). If p is the pitch of the
micrometer screw in cm, and m is the number of divisions on the circular scale, then
least count is p/m in cm.

8. Take a view through the eye piece of the tube as shown in Fig. 6.6.

9. There are two type of movements provided in the microscope, coarse and fine. Align
the microscope tube, with the help of coarse movement knob nos. 2 and 4 as shown
in Fig. 6.6, to bring it over the glass plate P 0 .

Figure 6.6: Experimental setup of Newton’s ring showing the screws

10. Now move the microscope tube with the help of fine movement knob no. 3 close to
the plate P 0 to obtain clear image of surface. Slowly move towards upward direction.
Newton’s rings pattern is observed. Adjust by moving the microscope to and fro, if
necessary, to view the full pattern. Adjust further for better contrast between bright
and dark fringes.

11. Bring the cross-wire, using knob no. 1 shown in Fig. 6.6, in the central fringe such
that their centre should coincide with each other.

12. Slide the cross-wire to the left till the vertical cross-wire line lies tangentially at the
20th ring. Note the reading on the main and circular scale using the light emitting
diode.

13. Now slowly slide the microscope to the right and note the reading when the vertical
cross-wire lies tangentially at the 16th, 12th, 8th and 4th rings respectively.

14. Keep sliding the microscope to the right and again note the readings when the vertical
cross-wire lies tangentially at the 4th, 8th, 12th, 16th and 20th rings respectively.

55
Ring

Sl. no. LHS RHS D= D2


b−a
(n)

MSR CSR Total MSR CSR Total


(a) (b)

(cm) (cm) (cm) (cm2 )

1 20

2 16

3 12

4 8

5 4

Table 6.1: Table for measurement of the diameter of the dark rings. MSR - Main scale
reading, CSR - Circular scale reading.

15. The radius of curvature (R) of the plano-convex lens is 100 cm which can be calcu-
lated using the following formula

!
1 1 1
= (µg − 1) − , (6.13)
f R Rp

where, f = focal length of the lens = 200 cm,


µg = refractive index of the material of the lens (i.e glass) = 1.5,
R = Radius of curvature of one side the convex side of the plano-convex lens,
Rp = Radius of curvature of plane side of the plano-convex lens → ∞.

16. Plot the graph D2 as a function of n. This should be a straight line passing through
the origin (See Eq. 6.12).

17. Find the slope of the line from the graph.

18. Find the wavelength of sodium light from this slope using Eq. 6.12.

Results
The wavelength of sodium light is nm.

56
Experiment 7

Gyroscope

A. Gyroscope

Purpose
To find the moment of inertia of gyroscope by measuring the precession frequency as a
function of spin frequency of gyroscope.

Apparatus
Gyroscope, tachometer, stopwatch, weights.

Theory
Gyroscopes are used in compasses, in the steering mechanism of torpedoes and in inertial
guidance systems. The objective is to find the moment of inertia of the gyroscope by
measuring the precession frequency, as a function of the spin frequency of the gyroscope.
The gyroscope that is free to rotate about all the three axes is balanced in horizontal
position with the help of a counter weight C as shown in Fig. 7.1. As soon as a small
weight is added on the left hand side of counter weight C, the gyroscope destabilizes and
falls down. Remove the extra small weight, balance it again as before and spin the disk
of the gyroscope with some angular velocity. Now hang the small weight again on the
left hand side as before. The gyroscope now shows a completely new behavior and starts
rotating in a direction perpendicular to the previous plane. This movement is known as
precession. That is how a gyroscope increases the stability of a system. Try to explain
this behavior using laws of mechanics. Can you cite some example from our everyday life
where you see actual demonstration of this gyroscopic phenomenon?
If I is the moment of inertia of the gyroscope about its symmetric axis, the angular
momentum L ~ is given by,
~ = I~
L ωg (7.1)
where ω~ g is the angular velocity of the spinning gyroscope. Now, the addition of an
additional weight m, at a distance r from the pivot point P , introduces a supplementary
torque ~τ
~
dL
|~τ | = mgr = (7.2)
dt
The gyroscope now starts precising with frequency ωp under the influence of ~τ . Since ~τ is
~ its effect is to change the direction of L.
perpendicular to L ~ In a time dt, L
~ will rotate by

57
Figure 7.1: Gyroscope experimental setup

dφ, given by

~ = |L|dφ
dL ~ (7.3)

dφ ~
1 dL 1 dL~ mgr
ωp = = = = (7.4)
dt ~ dt
|L| Iωg dt Iωg

where we have used Eqns. 7.1, 7.2 and 7.3. If Tp is the time for one precession revolution
and T is the time taken by the gyroscope to spin about its axis (one rotation) then

ωg = , (7.5)
Tg

ωp = , (7.6)
Tp

Therefore from Eqn. 7.4,

1 mgr
 
= Tp . (7.7)
Tg 4π 2 I

Thus a plot of 1/Tg vs Tp should yield a straight line for a fixed m, from which the moment
of inertia I of the gyroscope, can be obtained.

58
Procedure
Balance the gyroscope horizontally, using the counterweight C, without any weight m.

1. Give a spin to the horizontal balanced gyroscope and measure the time (Tg ) required
to complete one revolution using the given light barrier counter.

2. Immediately after this, hand a mass m into the groove at the longer end of the
gyroscope. This is at a distance r = 27cm. The gyroscope will precess. Using the
stop watch, measure the duration of half the rotation Tp /2.

3. Without any delay, remove the mass m, so that gyroscope stops processing, and
measure Tg again, using the light barrier counter.

4. The average of Tg measured in steps (1) and (3) above is to be used in Eq. (7.7).

5. Repeat for several different initial spins of the gyroscope and fixed m and plot 1/Tg
vs Tp and find the slope. Find I using Eq. (7.7).

6. Find I for another value of m.

Observation
For mass m = . . . . . . gm.

Sl. No. ωg1 ωg2 Mean ωg Tg 1/Tg Tp /2 Tp


(rpm) (rpm) ωgr (rad/ (sec) (sec−1 ) (sec) (sec)
(rpm) sec)
1

(ωg1 + ωg2 )
where, ωgr = (7.8)
 2 
ωgr
ωg = 2π (7.9)
60

Tg = (7.10)
ωg

Repeat your observations for another mass.

Calculation
Plot a graph of 1/Tg vs Tp for both masses on the same graph paper using the same
axes. The graphs should be a straight line passing through origin. Find the slope (s) and
calculate the moment of inertia of the gyroscope from the obtained slope values.
mgr
I = (7.11)
4π 2 s

59
Result
Moment of inertia of the gyroscope

1. For mass m1 = . . . . . . . . . kg m2 .

2. For mass m2 = . . . . . . . . . kg m2 .

60
Experiment 8

Electromagnetic induction

Purpose
• To study electromagnetic induction by measuring the induced emf using Faraday
set-up.

Apparatus
Faraday setup, diode, capacitor, breadboard, connecting wire, oscilloscope.

Theory
Faraday’s law of electromagnetic induction tells us that a changing magnetic flux gives
rise to an induced emf ε given by

ε=− , (8.1)
dt
where φ is the magnetic flux. A simple apparatus, whose schematic is shown in Fig. (8.1),

Figure 8.1: Schematic of the coil moving in and out of the magnetic field.

enables us to change θ at different rates through a coil of suitable area of cross-section.


A rigid semicircular frame of aluminum is pivoted at the centre of the circular part of
the frame. The whole frame can oscillate freely in its own plane, about a horizontal axis

61
passing through its centre. A bar magnet is mounted at the centre of the arc and the arc
passes through a coil C.
The rate of change of flux through the coil and thus the (maximum) induced emf is
essentially proportional to the (maximum) velocity of the magnet, as it passes through
the coil. One can change the maximum velocity by choosing different amplitudes of oscil-
lations.
If I is the moment of inertia of the oscillatory system and Ω is the angular velocity
of the magnet, then the kinetic energy of the system is IΩ2 /2 and potential energy can
be represented by M gLef f (1 − cos θ) at any instant of time, where Lef f is the effective
length of the corresponding simple pendulum. If θmax is the maximum angular amplitude
and Ωmax is the maximum value of angular velocity, then
1 2
IΩ = M gLef f (1 − cos θmax )
2 max
2M gLef f
or, Ω2max = (1 − cos θmax ). (8.2)
I
The motion can be regarded approximately as simple harmonic and its time period is
given by,
s
I
T = 2π . (8.3)
M gLef f

From Eq. (8.2) and (8.3), we get



Ωmax = sin(θmax /2) (8.4)
T

vmax = Lef f sin(θmax /2) (8.5)
T
where vmax is the maximum linear velocity associated with Ωmax . Angular amplitude
θmax is directly measured from the instrument. Velocity is computed by measuring T and
θmax .

Procedure
• Connect the resistor, the diode and the capacitor given to you in series with the coil
as shown in figure 8.2. When the magnet is set in motion, it will induce an emf in
the coil. Since the circuit is complete, a current will flow through it charging the
capacitor. Observe the signal across resistor, diode and the capacitor as a function
of time.
The diode current can flow only if the voltage at A is greater than at B. Thus once
a capacitor attains some voltage ε, current can flow through the capacitor only if
the induced emf in the coil is greater than ε. If the time constant RC is not small
compared to the time taken for the magnet to cross the coil, the capacitor does not
get fully charged in single oscillation. It may take several oscillations to do so.
The maximum induced emf across the coil is the same as the maximum voltage εmax
across the capacitor terminals which is to be measured using the oscilloscope.
• Ensure that the support for the apparatus is vertical by adjusting leveling screws.
Adjust the weights W1 and W2 mounted on the horizontal bar to make zero of the
scale as the mean position. Centre of the magnet must be inside the coil.
• Find out the time period T for oscillations using a stop watch. Take three sets of
readings, each for 20 oscillations, for five different values of θmax . Record them in a
table as shown in the next section.

62
Figure 8.2: Circuit diagram for charging of a capacitor

• Calculate vmax using Eq. (8.5) and within the approximation Lef f ≈ L, i.e. the
effective length of the simple pendulum is approximately equal to the radius of the
semicircular frame used here.
• Plot a graph between εmax vs vmax .

Observation Table
Sl. θ0 1 2 3 Avg T max vmax
T20
(deg) T20 max T20 max T20 max (sec) (sec) (V) (m/s)
(sec) (V) (sec) (V) (sec) (V)
1
2
3
4
5

Important notes
• vmax dependence of max :
The emf induced in the coil can be written as,
dφ dθ dφ
 
ε=− = −Ω . (8.6)
dθ dt dθ
Note that when the magnet is at its mean position, then Ω = Ωmax or velocity is at
its maximum since Vmax = Ωmax L. However, dφ/dθ = 0 at that point. Hence emf
will go through a zero corresponding to the mean position.
As an aside you may note (you are not required to perform this part)
!
dε d2 φ
 
=− Ω2max . (8.7)
dt Vmax dθ2 vmax

Hence a plot of the slope of ε(t) at the zero, corresponding to the mean position
2
against vmax would be linear. The proportionality constant depends only on the
geometry of the coil and the magnet.
• You may further note that the successive oscillations are not of the same amplitude.
This is due to damping. Possible sources are: (i) air resistance, (ii) friction at the
point of suspension, and (iii) induced emf (Lenz’s law).

63
Experiment 9

Mechanical waves

Purpose
• Study wavelength (λ) as function of frequency (ν) and to find out the phase velocity
vp of a traveling wave in a string.

• To measure linear mass density µ of the string.

Apparatus
Function generator, amplifier, mechanical oscillator, rubber rope, measuring tape, support
rod, support base, and weights.

Theory
A wave is an oscillation which propagates itself in space and time and usually periodically
through matter and space. One can differentiate between transverse and longitudinal
waves. In the case of transverse waves, the oscillation is perpendicular to the direction
of the propagation of the wave. In the case of longitudinal waves, the oscillation and the
propagation are in the same direction.
Our goal here is to find out the phase velocity of a wave. In order to calculate the
velocity we need to know the frequency and the wavelength. Frequency is generated by
function generator and is an independent variable here. So our main task is to calculate
wavelength of the wave. Here in this experiment we calculate wavelength using a novel
technique.
A standing wave is created by reflecting the wave from its opposite end. The distance
between the nodes is measured and thus the wavelength is calculated.
A typical harmonic wave can be represented as,

y = A sin(kx − ωt) (9.1)

where, y is the displacement of the particle from its mean position at a position x and at a time t.
A is the amplitude of the oscilation.
k is called the wave number and is related to the
wavelength λ by the relation k = 2π/λ.
ω is called the angular frequency (measuered in
radians per meter) and is 2π times the frequency.

64
Now consider two transverse waves having same amplitude, frequency, and wavelength but
travelling in opposite directions in the same medium

y1 = A sin(kx − ωt)
and y2 = A sin(kx + ωt) (9.2)

where y1 represents a wave traveling in the +x direction and y2 represents a wave traveling
in −x direction. Adding these two functions gives the resultant wave function y

y = y1 + y2 (9.3)
= A sin(kx − ωt) + A sin(kx + ωt)
y = 2A sin(kx) cos(ωt) (9.4)

This represents a wave function of standing waves. The speed of a wave on a string which
is under tension T and having a mass per unit length µ is given by
s
ω T
vp = = f λ = (9.5)
k µ

and is called the phase velocity.

Experimental setup
A schematic diagram of the experimental setup is shown in Fig. 9.1 while Fig. 9.2 shows
the various intruments of the experiment.

Figure 9.1: Schematic of standing wave generation

65
Figure 9.2: Experimental setup

Observation
For a given setup, record

1. Frequency from the function generator (10 Hz − 25 Hz).

2. Tension from the weight attached to the rope through the pulley.

3. Wavelength from the position of the nodes.

For constant mass m = . . . . . . . . . kg

Sl. Frequency (f ) Number of Length (L) λ = 2L/n 1/λ (cm−1 )


(Hz) loops (n) (cm) (cm)
1
2
3
4

For varying mass

Sl. Mass Frequency T = mg Number Length λ= vp = f λ vp2


(m) (f ) (N) of loops (L) 2L/n (cm/s) (cm/s)2
(Kg) (Hz) (n) (cm) (cm)
1
2
3
4

Calculation
1. Plot the 1/λ vs frequency graph. From this graph, the phase velocity vp should be
determined. Keep the tension in the string constant i.e. mass is constant.

66
2. The phase velocity vp of the rope waves, which depends on the tensile stress (T ) on
the rope, is to be measured for a given frequency. Plot vp2 vs T and hence find the
mass/unit length of the string using Eq. (9.5).

Results
1. Phase velocity (for constant mass) vp = . . . . . . . . .

2. Mass per unit length (for constant frequency) µ = . . . . . . . . .

67
Experiment 10

Fraunhoffer Diffraction

Purpose
• To understand what is meant by Fraunhoffer diffraction.

• To observe single slit diffraction patterns and plot the intensity profile of the pattern.

• Determine slit width from the diffraction formula.

Apparatus
Digital Multi-meter (DMM), He-Ne laser source, sliding detector (photocell), optical rail
and mounts.

Theory
Diffraction is the wave phenomenon which describes the deviation from straight line prop-
agation of a wave when it encounters an obstruction. In the case of light waves both
opaque and transparent obstacles cause this effect which results in shadow patterns on a
screen which are quite different from those expected if light travelled only in straight lines.
There are basically two categories of diffraction effects. The first is Fraunhoffer diffrac-
tion, which occurs when the waves incident on the slit and the screen (detector) are plane
waves. This diffraction is produced when both the light source and screen are effectively
at an infinite distance from the given obstacle. Fresnel diffraction is the second type
and refers to diffraction produced when either the source or screen or both are at finite
distances from the obstacle.
We can observe Fraunhoffer diffraction experimentally by using a collimated light
source and (i) placing the viewing screen at the focal plane of a convex lens located
behind the obstacle or (ii) by placing the screen at a large distance from the obstacle. The
schematic of a single slit diffraction apparatus is shown in Fig. 10.1.
In this experiment we concentrate on Fraunhoffer diffraction patterns although you
can observe the different patterns produced by Fresnel diffraction by placing the viewing
screen close to the diffraction slit used.
Fig. 10.1 shows a plane wave of wavelength λ incident on a slit width a. The diffrac-
tion pattern, intensity versus y is plotted in the figure. Wave theory predicts that the
Fraunhoffer diffraction pattern intensity due to a rectangular slit will be of the form

sin2 β
I = Io (10.1)
β2

68
where β = (ka sin θ)/2, k = 2π/λ, a = slit width and θ = angle formed by the light ray
with respect to the system central axis. The minima in the diffraction pattern occurs
when I(θ) = 0. This condition requires that

a sin θm = mλ (10.2)

where, m is the order number in diffraction pattern and θm is angle measured with respect
to system central axis to the mth order minima. The shape of this pattern is shown in

Figure 10.1: The Fraunhoffer diffraction pattern of a single slit.

Fig. 10.1. If θm is small, then



sin θm ≈ θm = . (10.3)
a
Further from geometry we have
y
sin θm ≈ θm = . (10.4)
D
where y = the distance between central maxima to the mth order minima point and D =
distance between slit and photo diode (observed form instrument). Combining Eqs. 10.3
and 10.4, the slit width can be calculated as
mλD
a= (10.5)
y

Experimental procedure
1. Let the laser warm up for at least fifteen minutes before starting the experiment.

2. Position the laser at one end of the bench and align the beam so that it travels
parallel to and along the central axis of the bench all along its length.

3. Let the beam pass through a beam expander. Adjust the slit position until the laser
beam is incident on the full width of the slit.

69
Figure 10.2: Experimental setup for single slit diffraction pattern

4. Attach the viewing screen to a component carrier and position it at the end of the
bench furthest from the laser.

5. Observe the diffraction pattern on the screen. Adjust the screen position if necessary
to obtain image clarity. Sketch the pattern observed for two different slit widths.
What is the effect of varying the slit width?

6. Now replace the screen with the sliding detector. Beware that the smallest division
on the sliding detector is 0.01 cm, and the detector can be moved over a distance of
4 cm. Check that the un-obstructed laser beam is at the proper level to be incident
on the detector central slit-adjust if necessary.

7. Adjust the position of the slit along the optical bench until the central (principal)
maximum and the first subsidiary maxima of the single slit diffraction pattern are
fully extended along the direction of travel of the detector–obviously the pattern
gets wider as the slit is moved closer to the laser and hence further away from the
detector.

8. Form a clear diffraction pattern and SLOWLY scan the pattern from the central
maxima to first maxima on the one side with the sliding detector for every 25 divi-
sions of the circular scale.

9. Plot intensity versus position. How do your results agree with theoretical predic-
tions?

10. Calculate the slit width using the diffraction Eq 10.5.

70
Observation
Distance
Sl. No. Intensity (mV)
MSR (mm) VSR Total reading
(mm)
1.

2.

3.
.. .. .. .. ..
. . . . .

Result
The calculated slit width from the diffraction pattern a = ............. mm.

Precautions
1. Never look directly into the laser beam and take care to avoid reflections entering
your eyes.

2. Do not disturb the setup once the diffraction pattern has been obtained.

3. Do not use the backlight of the multimeter. This would drain the battery of the
multimeter.

4. Avoid stray light falling on the photo detector while measuring the instensity of light.

71
Experiment 11

Diffraction grating

Purpose
• To understand the diffraction, diffraction grating and how diffraction grating works
with the help of basic diffraction grating equations and experimental studies.

• To measure the wavelength of the light source with the help of diffraction grating.

Apparatus
Spectrometer, diffraction grating, mercury light source, high voltage power supply, mag-
nifying lens, spirit level, torch light, etc.

Theory
Preliminary discussion
Interference refers to the interaction of two or more wave trains of light having the same fre-
quency and having a phase difference which remains constant with time (coherent sources),
so that they may combine with the result that the energy is not distributed uniformly in
space but is a maximum at certain points and a minimum (perhaps zero) at others.
Diffraction phenomenon is described as the apparent bending of waves around small
obstacles and the spreading out of waves past small openings. Diffraction patterns are
marked by a rapid decrease in intensity with increasing distance from the center of the
pattern.
A diffraction grating is made by making many parallel scratches on the surface of a
flat piece of transparent material. It is possible to put a large number of scratches per
centimeter on the material, e.g., the grating to be used has 6000 lines/cm on it. The
scratches are opaque but the areas between the scratches can transmit light. Thus, a
diffraction grating becomes a multitude of parallel slit sources when light falls upon it.

Diffraction grating equation


When parallel bundle of rays falls on the grating, these rays and their associated wave
fronts form an orthogonal set so the wave fronts are perpendicular to the rays and parallel
to the grating (as shown in Fig. 11.1). According to Huygens’ Principle, every point on a
wave front acts like a new source, each transparent slit becomes a new source so cylindrical
wave fronts spread out from each. These wave fronts interfere either constructively or
destructively depending on how the peaks and valleys of the waves are related.
Whenever the difference in path length between the light passing through different slits
is an integral number of wavelengths of the incident light, the light from each of these slits

72
will be in phase, and then it will form an image at the specified location. Mathematically,
the relation is simple

mλ = d sin θm (11.1)

Eq. (11.1) is known as grating equation. The light that corresponds to direct transmission

Figure 11.1: Geometrical conditions for the Figure 11.2: Spectrum due to a
diffraction from multiline grating. grating.

(or specular reflection in the case of a reflection grating) is called the zero order, and is
denoted m = 0. The other maxima occur at angles which are represented by non-zero
integers m. Note that m can be positive or negative, resulting in diffracted orders on both
side of the zero order beam.
Diffraction gratings are often used in monochromators, spectrometers, lasers, wave-
length division multiplexing devices, optical pulse compressing devices, and many other
optical instruments.

Resolving power of grating


This equation then leads to the following expression for the resolving power of the diffrac-
tion grating
λ
R= = mN (11.2)
∆λ
Here λ is the average of wavelength, ∆λ is the difference between wavelengths, m is the
order and N is the total number of slits on the grating.
Thus, the distance between maxima depends on the distance between slits and the res-
olution, the relative sharpness of the maxima, depends on the total number of slits. (Often
a grating is characterized by the number of slits per unit length. From this information
one can, of course, deduce the distance between the slits.

Procedure
As with many optical instruments, the spectroscope requires some initial adjustments
before the desired measurements can be performed. Focusing and levelling of the spec-
trometer for the parallel rays is to be done as per previous prism experiment.

73
(a) (b)

Figure 11.3: Grating settings

To set the telescope axis perpendicular to that of the collimator:


Illuminate the slit with the light source. Turn the telescope of the spectrometer to view the
image of the illuminated slit directly as shown in Fig. 11.3(a). The source should directly
be in front of the slit such that maximum light falls on the slit. Adjust the cross-wires
such that the image of the slit falls in the middle of the intersection of the cross-wires.
Fix the prism table with the fixing screw and read any of the two verniers. Let this angle
be α. Rotate the telescope by an amount 90 ± α such that it is exactly perpendicular to
the collimator. Fix the telescope in this position and unfix the prism table.
Fix the grating (G) in the grating holder such that the grating lines are perpendicular
to the prism table and the ruled surface extend equally on both sides of the center. The
grating is set parallel to the line joining the prism table screws B and C as shown in
Fig. 11.3. Turn the prism table such that light from the collimator is reflected into the
telescope. The reflection should be by the unruled surface of the grating. To determine
the unruled surface use the following procedure. Allow light to be reflected by both the
grating surface one at a time and view the corresponding image via the telescope. The
surface from which the image of the slit appears sharper is in fact the unruled surface of
the grating.
Once the unruled surface has been determined, view the reflection only via the unruled
surface while the setup is as shown in Fig. 11.3(b). If the center of the grating displace
either above or below the intersection of the cross-wires, then the grating surface is not
vertical. To ensure that the grating surface is vertical, turn the prism table screws B and C
equally in opposite directions until the center of the image coincides with the intersection
of the cross-wires.
Turn the unruled surface of the grating by an angle 45◦ such that the light from the
collimator falls normally on the unruled surface of the grating. Fix the prism table in this
position and unfix the telescope.
Even though we have made the plane of the grating vertical and the rulings perpen-
dicular to the table surface, the rulings of the grating may not be vertical. In order to
set the rulings vertical, rotate the telescope in its own plane on both side of the central
image. On both sides on the central image different orders of image are seen as shown in

74
Fig. 11.4. In the first order images on both sides, if the image on the left is higher than

Figure 11.4: Grating images of higher order

that of the image on the right or vice-versa, then turn the third screw A on the prism
table until the images on both the sides are on the same level.

Caution
• The diffraction grating is a photographic reproduction and should NOT be touched.
Make sure that the glassy base of grating shouldn’t faces towards the source light.

• Now your setup is ready to report the experimental observations.

Observation
1. Check to make sure that the grating is not too high or low relative to the collimator.
Affirm maximum brightness for the straight through beam by adjusting the source
slit alignment. At this step, the slit should be narrow, perhaps a few times wider
than the hairline. Search for the spectrum by moving the telescope to one side or
the other. This spectrum should look much like the visible spectrum observed with
the prism. This is the first order spectrum. Record for each color diffraction angle
θR (along right side) and θL (along left side) from the straight trough beam.

2. For each of the seven colors in the mercury spectrum, measure the angles θR and θL
to the nearest tenth of a degree by placing the hairline on the stationary side of the
slit.

3. You are expected to observe the 1st order diffraction pattern.

4. From your observations calculate various wavelengths of visible radiations from the
mercury source.

Calculation
1. Use the grating equation with d = (1/6000) cm to find the wavelength λ for each
colour.

2. Calculate % error for your reported λ measurement.

75
Sl. Colour LHS RHS 2θ = θ λ=
d sin θ
θL − m=1
θR

CSR VSR Total CSR VSR Total


(θL ) (θR )

1 Violet

2 Indigo

3 Blue

4 Green

5 Yellow

6 Orange

7 Red

Table 11.1: For first order (m = 1). CSR - Circular scale reading, VSR - Vernier scale
reading.

Result
1. Percentage measurement error for your analysis.

2. A certain colour emerges at 15o in the first order spectrum. At what angle would
this same colour emerge in the second order if the same source and grating are used?

3. What could be causing any discrepancy?

4. Why is it necessary that the base side of the grating face toward the light source?
Draw a ray diagram for the two cases:

a) Base toward the source (correct).


b) Grating toward the source (incorrect).

5. Mention your special comments for each statement in your lab report as a part of
experimental outputs.

76