Featuring Coreless Element Technology

9020/21/24 Series OPTIONAL


DIFFERENTIAL
PRESSURE DEVICES

Filter Assemblies
Flows to 20 gpm (75 L/min)
Pressures to 3000 psi (207 bar) EXTRUDED
ALUMINUM
Port size 3⁄4" ALLOY HEAD
(ANODIZED)

Notes and Specifications


Maximum Acceptable
Working Pressure: 3000 psi (207 bar)
Fatigue Pressure Rating: R length–1800 psi (124 bar)
(NFPA/T2.6.1-1974 S length–1500 psi (103 bar)
category 2/90)
Typical Burst Pressure: 15,000 psi (1035 bar) O-RING
FULL FLOW SEALS
Temperature Range: Nitrile seals–45°F to 225°F FAST RESPONSE
BYPASS VALVE
(–43°C to 107°C)
Fluorocarbon seals–20°F
to 250°F (–27°C to 121°C)
140°F (60°C) maximum in
HWCF or water-glycol fluids
ULTIPOR® III
Dry Weights: R length–3.7 lbs. (1.7 kg) ELEMENT
S length–5 lbs. (2.3 kg)
FORGED
Filter Element 9020–290 psid (20 bar) ALUMINUM
Collapse Pressure: 9021–3000 psid (207 bar) ALLOY BOWL
(ANODIZED)
9024–150 psid (10 bar)

Pressure Drop Information


Figure 1. Housing Pressure Drop using Figure 2. Bypass Valve Pressure Drop Element Pressure Drop Factor.
fluid with 0.9 S.G. Housing Pressure drop is using fluid with 0.9 S.G. Bypass valve Multiply actual flow rate times factor to
directly proportional to specific gravity. pressure drops are directly proportional determine pressure drop with fluid at 150
to specific gravity. SUS (32 cSt), 0.9 S.G. Correct for other
viscosities by multiplying new viscosity in
FLOW (L/MIN) FLOW (L/MIN)
SUS/150 x new S.G/0.9.
0 20 40 60 80 0 20 40 60 80
25 200
9020 Series Element ∆P factor (psid/gpm)
-1.5 -12.0
20 150 Length KZ KP KN KS KT
4" 1.90 0.82 0.54 0.35 0.21
15 120 -8.0
∆P(BAR)

∆P(PSID)
∆P(PSID)

∆P(BAR)

-1.0
8" 0.96 0.41 0.27 0.18 0.11
10 60
9021 Series Element ∆P factor (psid/gpm)
-0.5 -4.0
5 40 Length DP DT
4" 2.71 0.68
-0 -0
0 5 10 15 20 25 0 5 10 15 20 25 30 8" 1.35 0.34
FLOW (GPM) FLOW (GPM)

9024 Series Element ∆P factor (psid/gpm)


Length KZ KP KN KS KT
8" 1.12 0.48 0.31 0.21 0.13

50
Dimensional Drawings

FOR “H”
DIMENSION 2.04 IN.
SEE INDICATOR 51.8 MM
SECTION

.91 IN.
.75 IN. 23.1 MM
19.0 MM

OUTLET
INLET
2.90 IN.
73.7 MM
INLET OUTLET

1.00 IN.
.270 IN. 25.4 MM
6.86 MM
DIA. MTG.
HOLES 4.09 IN.
(2) PLACES 103.8 MM

3.12 IN.
79.2 MM
1.56 IN.
39.6 MM

R 5.76 IN. 146.3 MM


S 9.64 IN. 244.9 MM 1.250 IN. .670 IN.

9020/21/24 SERIES
31.8 MM 17.0 MM

3000 PSI/20 GPM


FOR “H”
DIMENSION
SEE
INDICATOR
SECTION

.625 IN.
15.9 MM
1.250 IN.
31.8 MM

.688 IN. OUTLET INLET


17.4 MM
.345 IN.
8.8 MM
DIA. HOLE
THROUGH 3.50 IN.
(4) MTG. HOLES 88.9 MM
2.50 IN. DIA.
63.5 MM
TOP VIEW
2.50 IN. 9024 MINIMUM CLEARANCE “K” OPTION HEAD
63.5 MM FOR ELEMENT REMOVAL
MIN. CLEARANCE
REQUIRED FOR S 8.32 IN. 211.3 MM
BOWL AND ELEMENT
REMOVAL (9020/21)

Ordering Information
Assembly P/N: H 902
TABLE 1 TABLE 2 TABLE 3 TABLE 4 TABLE 5 TABLE 6 TABLE 7 TABLE 8

Element P/N: HC 902 F


TABLE 2 TABLE 5 TABLE 6 TABLE 1

Table 1. Seal Options Table 2. Element Options Table 3. Port Style Options Table 4. Port Size Options
Code Seals Code Rating Code Port Style Code Size
H Nitrile 0 290 psid (standard) A SAE J514 straight thread 12 ⁄4"
3

Z Fluorocarbon 1 3000 psid (high collapse) L Manifold side mount*


4 150 psid (coreless) K Manifold mount
*Contact factory for drawings.

Table 5. Filter Element Options Table 6. Length Options* Table 7. Bypass Valve Options Table 8. Differential Pressure Device Options

Code βx≥200 βx(c)=1000 Assembly Element Code Description Code Description


Code Code**
B 50 psid- P Visual indicator with thermal lockout
KZ <1 2.5 R 4 9020/9024 only D Visual indicator with no thermal lockout
KP 3 5 S 8 W Non bypass L Electrical switch (SPDT) with 6" leads
KN 6 7 * Use code in second column 9021 only
for element part no. T Electrical switch with DIN connector
KS 12 12 ** Nominal length in inches
M ‘T’ type switch with matching wiring cap
KT 25 22
S Electrical switch with MS receptacle
DP* 3 5
V Combined visual/electrical
DT* 17 15 with DIN connector
*9021 series only.
See page 17 for filter specifications. B Plug in place of indicator
See page 140.

FOR TECHNICAL ASSISTANCE CALL TOLL FREE 1-888-333-PALL (7255) ©Copyright 1998, 2000, Pall Corporation. All rights reserved.