4710 - 11 - 14 Series - 6500 Psi

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

Featuring Coreless Element Technology

4710/11/14 Series DUCTILE IRON


HEAD

Filter Assemblies
Flows to 130 gpm (490 L/min) OPTIONAL FULL FLOW FAST
RESPONSE
Pressures to 6500 psi (450 bar) DIFFERENTIAL
PRESSURE BYPASS VALVE
Port sizes 11⁄4" and 11⁄2" DEVICES

Notes and Specifications


Maximum Acceptable
Working Pressure: 6500 psi (450 bar) SAMPLING OR
BLEED PORT
Fatigue Pressure Rating: 5800 psi (400 bar) Stainless
(NFPA/T2.6.1-1991 steel indicators required
category B/90) above 3000 psi (207 bar) RFP
PATENTED SEALING
Typical Burst Pressure: 23,000 psi (1600 bar) INTERFACE
Positive sealing with
standard O-rings
Temperature Range: Nitrile seals–45°F to 225°F
(–43°C to 107°C)
Fluorocarbon seals–20°F
to 250°F (–29°C to 120°C)
140°F (60°C) maximum in
HWCF or water glycol fluids
Dry Weights: T length- 54 lbs. (24.5 kg) ULTIPOR® III
U length- 60 lbs. (27 kg) ELEMENT

Filter Element 9600–290 psid (20 bar)


Collapse Pressure: 9601–3000 psid (207 bar)
4704–150 psid (10 bar)

FORGED STEEL
BOWL

OPTIONAL 1⁄4"
DRAIN PORT

Pressure Drop Information


Figure 1. Housing Pressure Drop using Figure 2. Bypass Valve Pressure Drop Element Pressure Drop Factor.
fluid with 0.9 S.G. Housing Pressure drop is using fluid with 0.9 S.G. Bypass valve Multiply actual flow rate times factor to
directly proportional to specific gravity. pressure drops are directly proportional determine pressure drop with fluid at 150
to specific gravity. SUS (32 cSt), 0.9 S.G. Correct for other
viscosities by multiplying new viscosity in
FLOW (L/MIN) FLOW (L/MIN) SUS/150 x new S.G/0.9.
0 100 200 300 400 500 600 0 100 200 300 400 500 600
25 100
-1.5 -6.0 9600/4704 Series Element ∆P factor (psid/gpm)
20 80
BYPASS OPTION Length KZ KP KN KS KT
“B” OR “C”
-1.0 -4.0 13" 0.27 0.12 0.10 0.07 0.05
∆P(PSID)

∆P(BAR)

∆P(PSID)

15
∆P(BAR)

60
16" 0.20 0.09 0.07 0.05 0.04
10 1 1/4" PORTS 40
-0.5 -2.0
PRESSURE DROP IN
REVERSE DIRECTION
9601 Series Element ∆P factor (psid/gpm)
5 20
1 1/2" PORTS ADDITIVE ∆P IN
FORWARD DIRECTION Length DP DT
-0 -0
0 20 40 60 80 100 120 140 160 0 20 40 60 80 100 120 140 160 13" 0.32 0.08
FLOW (GPM) FLOW (GPM)
16" 0.25 0.07

66
Dimensional Drawings

OUTLET
7.20 IN. 3 MOUNTING HOLES 1.77 IN. 1.77 IN.
183 MM 1/2" - 13 UNC 45 MM 45 MM
INLET TO MIN. DEPTH OF 0.7"
6.02 IN.
5.51 IN. 153 MM
140 MM
0.71 IN.
3.66 IN. 18 MM
3.23 IN. 93 MM
82 MM

5.51 IN. 1.42 IN.


140 MM DIA. 36 MM 2.20 IN.
SAMPLE PORT 56 MM
3.43 IN.
87 MM
FOR “H” DIMENSION
SEE INDICATOR
SECTION
0.79 IN. 0.79 IN.
T 13.39 IN. 340 MM 20 MM 20 MM
U 17.32 IN. 440 MM

4710/11/14 SERIES
6500 PSI/130 GPM
2.75 IN.
70 MM MIN.
MIN CLEARANCE REQUIRED
OPTIONAL 3/8" SAE FOR REMOVAL OF ELEMENT 4710/11
DRAIN PORT
MINIMUM CLEARANCE REQUIRED
FOR REMOVAL OF ELEMENT 4714
T 13.7 IN. 350 MM
U 17.7 IN. 450 MM

Ordering Information
Assembly P/N: H 471 3
TABLE 1 TABLE 2 TABLE 3 TABLE 4 TABLE 5 TABLE 6 TABLE 7 TABLE 8

Element P/N: HC F
TABLE 2 TABLE 5 TABLE 6 TABLE 1

Table 1. Seal Options Table 2. Element Options Table 3. Port Style Options Table 4. Port Size Options
Code Seals Assembly Element Code Port Style Code Size
Code Code Rating
H Nitrile A SAE J514 straight thread 20 1 1⁄4"
0 9600 290 psid (standard)
Z Fluorocarbon D Flange SAE J518c-code 61 24 1 1⁄2"
1 9601 3000 psid (high collapse)
E Flange SAE J518c-code 62
4 4704 150 psid (coreless)

Table 5. Filter Element Options Table 6. Length Options* Table 7. Bypass Valve Options Table 8. Differential Pressure Device Options
Code βx≥200 βx(c)=1000 Assembly Element Code Description Code Description
Code Code**
B 50 psid- 4710/14 only P Visual indicator with thermal lockout
KZ <1 2.5 T 13
C 50 psid bypass D Visual indicator with no thermal
KP 3 5 U 16 with reverse flow- lockout
KN 6 7 * Use code in second column 4710 only L Electrical switch (SPDT) with 6" leads
KS 12 12 for element part no. W Non bypass-
** Nominal length in inches T Electrical switch with DIN connector
4711 only
KT 25 22 M ‘T’ type switch with matching wiring
K Non bypass cap
DP* 3 5 with reverse flow-
DT* 17 15 4711 only S Electrical switch with MS receptacle
*4711 only. V Combined visual/electrical
See page 17 for filter specifications. with DIN connector
* Indicators fatigue rated at 3000 psi.
For cyclic pressures above 3000 psi, B Bleed plug and seal in place of
stainless steel indicators are indicator
necessary. Designate with an ‘H’ in
model code (e.g. PH, DH, etc.). 2 ‘P’ and ‘L’
3 ‘P’ and ‘S’
See page 140.

FOR TECHNICAL ASSISTANCE CALL TOLL FREE 1-888-333-PALL (7255) ©Copyright 1998, 2000, Pall Corporation. All rights reserved.