Fire Protection System Boq
Fire Protection System Boq
Fire Protection System Boq
Sl.No DESCRIPTION
APPROVED MAKES
AUDCO
AUDCO
UNIVERSAL
SAFEGUARD
SAFEGUARD
SAFEGUARD
SAFEGUARD / FABRICATED
SAFEGUARD
SAFEGUARD
DUNLOP
KEI
PROJECT : IIIT
LOCATION : HYDERABAD
DOCUMENT : SPRINKLER SYSTEM- ACADAMIC BUILDING
SI.No Descriptions Unit
Note:
Vendor to visit the site & quote accordingly
All the paints used for piping, fittings, valves and accessories shall
have VOC level below 250 g/ltrs. VOC level for any sealants shall be
less than 250 g/ltrs and for rubber lining 850g/ltrs.
Dial type pressure guage for (0-16 Kg/cm2) with necessary nipple &
3 other fittings, mounting arrangements and with a 15 mm ball valve Nos
TOTAL
AMC Cost
Charges for Comprehensive Annual Maintenance Charges for a
period of 5 years from the end of Guarantee period.
I year Lot
II year Lot
III year Lot
IV year Lot
V year Lot
PROJECT : IIIT
LOCATION : HYDERABAD
DOCUMENT :- CONTROLLED FOR INTERNAL HYDRANT SYSTEM - ACADAMIC BUILDING
EXTER
SL.No DESCRIPTION GF 1F 2F
.
Supplying, erecting and commissioning of Landing Hydrants comprising of the following in the Fire
duct;
Under Ground piping - Supply, erection, testing and commissioning of MS PIPES C CLASS pipes
conforming to IS 3589 for 200NB & above and IS 1239 for 150NB including cutting the pipes to correct
length, providing and welding flanges to pipe, etc as per specifications (rate including Anti-corrosive
Coating & Wrapping and heavy class forged fittings of IS standards) of the following diameters. brackets
testing to 13.5 Kg/Sq.cm hydraulic pressure after instalation,complete as per specification. Rates shall
1
be inclusive of 10% radiograph test complete as per specifications of the following diameters and all
necessary supports.
Note
Vendor to consider The pipe fittings shall be threaded up to 50 mm dia and Welded type for 65 mm dia
& above.
150mmdia - Riser 12 9 9
150mmdia (From Pump room to Risers) 580
100mmdia
80mmdia 18 156 156 156
25mmdia 4 4 4
Supply, installation, testing and commissioning of electrically driven pump set as per specification.
Motor TEFC type, 2900 RPM 415 V, 50 cycles, 3 phase, class ‘F’ insulation, IP 54 protection, 10 HP
starting on DOL. The Pump shall be horizontal end suction top discharge. The pump shall be weather
proof type. The pump shall have cast iron casing, Cast iron impeller, steel shaft with common base
3 frame capable of discharging 54 m3/hour at 45 meter head as per ISI Standard (rate is inclusive of
control panel, Cables, PS, PG and supports)
Supplying, Installing, testing and commissioning CAST IRON BUTTERFLY VALVE WAFER TYPE LEVER
4
OPERATED PN-1.6 WITH INTEGRALLY MOULDED LINER OF NITRLE OR EPDM, S.S. (CF-8) DISC, S.S STEM
150 NB 6
100 NB
Supplying and installation of CAST IRON NON RETURN VALVE FLANGED PN-1.6 S.S HING PIN, RUBBER
5
SEATED, DRILLING AS PER : IS-1538
150 NB
Supplying and installation of CAST IRON Y-TYPE STRAINERS (Flanged)PN-1.6 BODY,-C.I., SCREEN
6 STAINLESS STEEL
150 NB
Supplying, installing, testing and commissioning of Gun metal chrome finished 25mm dia Ball valves
7 4 4 4
with fittings of screwed end type.
Supply installation ,testing and commissioning of Single headed Hydrant valve confirming to IS 5290
8 with ISI mark of 63mm dia oblique type with instantaneous hose coupling adaptor etc complete as 8 4 4 4
required.
Supply, installation, testing and commissioning of 63 mm dia and 15m long RRL type with GM 63 mm
size male coupling at one end and female coupling at the other end etc complete. Hose shall comply to
9 IS:636 Type II and coupling to IS 903:1975 with IS certification. 16 8 8 8
Supply ,installation ,testing and commissioning of Short branch pipe with 63mm female instantaneous
10 inlet made of gun metal, male threaded outlet, complete with nozzle heavy quality conforming IS 903 8 4 4 4
etc.
Hose cabinet stand mounted type fabricated out of M.S. sheet of 16 swg. with glass fronted ( 4mm thick
glass with rubber beading) door and size of the cabinet shall be 600mm x 750 mm x 250 mm Quoted
rate shall be includes suitable stand for mounting for gnd lvl with supports, all fasteners etc, and cabinet
11 shall be powder coated of approved colour both inside and out side. 8 2 2 2
Supply ,installation, testing and commissioning of 25mm diameter FORGED BRASS AIR RELEASE
12 VALVES PN-1.6 BODY - FORGED BRASS 25 mm
Supply ,installation, testing and commissioning of Fire Hose Reel (as per ISI) wall mounted, swinging
type18 SWG MS sheet, fitted with 20 mm dia x 40 M long, high pressure hose with 5 mm outlet GM
13 nozzle with shut off valve (IS: 884) includes stop cock and chrome plated nozzle with all necessary fixing 4 4 4
materials complete.
Supply and fixing of Fire shaft door fabricated out of GI. sheet and frame, door shall be 900mm x
1500mm min with double leaf. & fixed with 4 mm thick Glass, suitable Rubber beeding and Locking
arrangement. Quoted rate shall be includes all fasteners etc, and complete shutter shall be powder
14 coated of approved colour both inside and out side. 2 2 2
Supply and installation of RCC hume pipes of 300 mm dia & NP 3 Class with collars for road / below
floor crossing of Fire water pipes. NP3 type hume pipe of the following diameter with necessary collars
conforming to IS 458 including cost and conveyance to site, laying to proper grade and alignment,
jointing etc. complete as per direction of the Engineer including cost and conveyance of all materials to
site, all labour, hire and fuel charges for all tools and plants employed and all other incidental charges
15 etc. complete as per specifications .The rate shall includes excavation, PCC ( 1:4:8 100 mm thick)bed and 24
ends shall be closed with Brick masonry work as directed by site engineer.
Supply & installation of Siamese inlet (Fire Brigade inlet) connection with provision for Four male
instantaneous coupling with MS cabinet fabricated. approved make heavy class GI pipe with non-return
valve,gate valve for fire fighting system including making connection by providing necessary piping &
fittings to the fire storage tank, fire fighting wet riser painting the same with 2 coats of enamel paint
16 over a coat of Zinc Chromate primer all complete as per drawings, specifications. Common for both 1
building Connection to yard line.
TOTAL - in Rs.
TOTAL INSTALLATI
3F 4F TER.F UNIT SUPPLY
QTY ON
UNIT RATE AMOUNT UNIT RATE AMOUNT
10 Rmt - -
9 9 48 Rmt - -
150 730 Rmt - -
10 Rmt - -
156 156 798 Rmt - -
4 4 20 Rmt - -
1 Nos - -
4 10 Nos - -
5 Nos - -
1 1 Nos - -
1 1 Nos - -
4 4 3 23 Nos - -
4 4 28 Nos - -
8 8 56 Nos - -
4 4 28 Nos - -
2 2 18 Nos - -
3 3 Nos - -
4 4 20 Nos - -
2 2 10 Nos - -
24 Rmt - -
1 Nos - -
- -
PROJECT : IIIT
LOCATION : HYDERABAD
DOCUMENT :- CONTROLLED FOR INTERNAL HYDRANT SYSTEM - SRIC BUILDING
SL.No DESCRIPTION EXT GF
Supplying, erecting and commissioning of Landing Hydrants comprising of the following in the Fire
duct;
Under Ground piping - Supply, erection, testing and commissioning of MS PIPES C CLASS pipes
conforming to IS 3589 for 200NB & above and IS 1239 for 150NB including cutting the pipes to correct
length, providing and welding flanges to pipe, etc as per specifications (rate including Anti-corrosive
Coating & Wrapping and heavy class forged fittings of IS standards) of the following diameters. brackets
testing to 13.5 Kg/Sq.cm hydraulic pressure after instalation,complete as per specification. Rates shall
1
be inclusive of 10% radiograph test complete as per specifications of the following diameters and all
necessary supports.
Note
Vendor to consider The pipe fittings shall be threaded up to 50 mm dia and Welded type for 65 mm dia
& above.
150mmdia - Riser 6
150mmdia (From Pump room to Risers) 492
150mmdia (From Accadamic Block shaft to Riser) 114
100mmdia
80mmdia 12 2
25mmdia 2
Supply, installation, testing and commissioning of electrically driven pump set as per specification.
Motor TEFC type, 2900 RPM 415 V, 50 cycles, 3 phase, class ‘F’ insulation, IP 54 protection, 10 HP
starting on DOL. The Pump shall be horizontal end suction top discharge. The pump shall be weather
proof type. The pump shall have cast iron casing, Cast iron impeller, steel shaft with common base
3 frame capable of discharging 27 m3/hour at 35 meter head as per ISI Standard (rate is inclusive of
control panel, Cables, PS, PG and supports)
Supplying, Installing, testing and commissioning CAST IRON BUTTERFLY VALVE WAFER TYPE LEVER
4
OPERATED PN-1.6 WITH INTEGRALLY MOULDED LINER OF NITRLE OR EPDM, S.S. (CF-8) DISC, S.S STEM
150 NB 3
100 NB
Supplying and installation of CAST IRON NON RETURN VALVE FLANGED PN-1.6 S.S HING PIN, RUBBER
5
SEATED, DRILLING AS PER : IS-1538
150 NB
Supplying and installation of CAST IRON Y-TYPE STRAINERS (Flanged)PN-1.6 BODY,-C.I., SCREEN
6 STAINLESS STEEL
150 NB
Supplying, installing, testing and commissioning of Gun metal chrome finished 25mm dia Ball valves
7 2
with fittings of screwed end type.
Supply installation ,testing and commissioning of Single headed Hydrant valve confirming to IS 5290
8 with ISI mark of 63mm dia oblique type with instantaneous hose coupling adaptor etc complete as 6 2
required.
Supply, installation, testing and commissioning of 63 mm dia and 15m long RRL type with GM 63 mm
size male coupling at one end and female coupling at the other end etc complete. Hose shall comply to
9 IS:636 Type II and coupling to IS 903:1975 with IS certification. 12 4
Supply ,installation ,testing and commissioning of Short branch pipe with 63mm female instantaneous
10 inlet made of gun metal, male threaded outlet, complete with nozzle heavy quality conforming IS 903 6 2
etc.
Hose cabinet stand mounted type fabricated out of M.S. sheet of 16 swg. with glass fronted ( 4mm thick
glass with rubber beading) door and size of the cabinet shall be 600mm x 750 mm x 250 mm Quoted
rate shall be includes suitable stand for mounting for gnd lvl with supports, all fasteners etc, and cabinet
11 shall be powder coated of approved colour both inside and out side. 6 2
Supply ,installation, testing and commissioning of 25mm diameter FORGED BRASS AIR RELEASE
12 VALVES PN-1.6 BODY - FORGED BRASS 25 mm
Supply ,installation, testing and commissioning of Fire Hose Reel (as per ISI) wall mounted, swinging
type18 SWG MS sheet, fitted with 20 mm dia x 40 M long, high pressure hose with 5 mm outlet GM
13 nozzle with shut off valve (IS: 884) includes stop cock and chrome plated nozzle with all necessary fixing 2
materials complete.
Supply and fixing of Fire shaft door fabricated out of GI. sheet and frame, door shall be 900mm x
1500mm min with double leaf. & fixed with 4 mm thick Glass, suitable Rubber beeding and Locking
arrangement. Quoted rate shall be includes all fasteners etc, and complete shutter shall be powder
14 coated of approved colour both inside and out side. (OPTIONAL)
Supply and installation of RCC hume pipes of 300 mm dia & NP 3 Class with collars for road / below
floor crossing of Fire water pipes. NP3 type hume pipe of the following diameter with necessary collars
conforming to IS 458 including cost and conveyance to site, laying to proper grade and alignment,
jointing etc. complete as per direction of the Engineer including cost and conveyance of all materials to
site, all labour, hire and fuel charges for all tools and plants employed and all other incidental charges
15 etc. complete as per specifications .The rate shall includes excavation, PCC ( 1:4:8 100 mm thick)bed and 24
ends shall be closed with Brick masonry work as directed by site engineer.
Supply & installation of Siamese inlet (Fire Brigade inlet) connection with provision for Four male
instantaneous coupling with MS cabinet fabricated. approved make heavy class GI pipe with non-return
valve,gate valve for fire fighting system including making connection by providing necessary piping &
fittings to the fire storage tank, fire fighting wet riser painting the same with 2 coats of enamel paint
16 over a coat of Zinc Chromate primer all complete as per drawings, specifications. Common for both 1
building Connection to yard line.
TOTAL - in Rs.
TOTAL INSTALLATI
MEZ.F 1F TER.F UNIT SUPPLY
QTY ON
UNIT RATE AMOUNT UNIT RATE AMOUNT
2 Rmt - -
6 6 18 Rmt - -
132 624 Rmt - -
114 Rmt - -
10 Rmt - -
2 2 18 Rmt - -
2 2 6 Rmt - -
1 Nos - -
3 6 Nos - -
5 Nos - -
1 1 Nos - -
1 1 Nos - -
2 2 1 7 Nos - -
2 2 12 Nos - -
4 4 24 Nos - -
2 2 12 Nos - -
2 2 12 Nos - -
1 1 Nos - -
2 2 6 Nos - -
1 Nos - -
24 Rmt - -
1 No - -
- -
PROJECT : IIIT
LOCATION : HYDERABAD
DOCUMENT :- CONTROLLED FOR FIRE PUMP ROOM
SL.NO DESCRIPTION QTY UNIT
Supply, installation, testing and commissioning of electrically Vertical Turbine driven pump set as per
specification. IEC / TEFC type, 2900 rpm, 415V, 50 cycle frequency 3 phase class ‘F’ insulation, I.P. 54 protection,
starting on Soft starter. The pump shall have cast iron casing, bronze impeller, steel shaft with common base
a. frame capable of discharging 137m3/hr at 120MWC-(Hydrant & Sprinkler Pumps). 2 Nos
Note : -
1.Rate shall inclusive of civil foundation for pump placement with accessories.
2.Pump Head has to be selected based on the hydraulic calculation done on the detailed engineering drawings
3 JOCKEY PUMPSET
Supply, installation, testing and commissioning of Vertical Turbine pump set as per specification. IEC /TEFC type,
2900 RPM 415 V, 50 cycles, 3 phase, class ‘F’ insulation, IP 54 protection, 20 HP starting on DOL starter. The
pump shall have cast iron casing, Cast iron impeller, steel shaft with common base frame capable of discharging
10.8m3/hour at 120MWC. (Hydrant & Sprinkler Pumps). 2 Nos
Note : -
1.Rate shall inclusive of civil foundation for pump placement with accessories.
2.Pump Head has to be selected based on the hydraulic calculation done on the detailed engineering drawings
4 Test Array Arrangement for pumpset with pressure switch valves pipes and fittings etc. 5 Set
5 Test Array Arrangement for pumpset with Dial type pressure gauge valves pipes and fittings etc. 2 Set
Supply, Erection, Testing and commissioning of CAST IRON SLUICE VALVE / GATE VALVE RISING STEM FLANGED
6
PN-1.6 S.S STEM, GUN METALWORKING PARTS, DRILLING AS PER : IS-1538
250 NB 1 Nos
200 NB 1 Nos
150 NB 1 Nos
100 NB 1 Nos
80 NB 1 Nos
Supplying, Installing, testing and commissioning CAST IRON BUTTERFLY VALVE WAFER TYPE LEVER OPERATED
7
PN-1.6 WITH INTEGRALLY MOULDED LINER OF NITRLE OR EPDM, S.S. (CF-8) DISC, S.S STEM
200 NB 1 Nos
150 NB 3 Nos
100 NB 1 Nos
65 NB. 2 Nos
Supply, installation, testing and commissioning of SS” stainless wired Expansion bellows (Flexible coupling) with
8
required flanges,nuts,bolts & accessories
200 NB 1 Nos
150 NB 3 Nos
80 NB 1 Nos
65 NB. 2 Nos
Supplying and installation of CAST IRON NON RETURN VALVE FLANGED PN-1.6 S.S HING PIN, RUBBER SEATED,
9
DRILLING AS PER : IS-1538
200 NB 1 Nos
150 NB 3 Nos
100 NB 1 Nos
65 NB. 2 Nos
Supplying and installation of CAST IRON Y-TYPE STRAINERS (Flanged)PN-1.6 BODY,-C.I., SCREEN STAINLESS
10 STEEL
250 NB 1 Nos
Supplying and installation of FORGED BRASS BALL VALVE PN- 2.5 BODY D.I. , FLAP S.S , SEATNITRILE OR EPDM
11
RUBBER
50 NB 5 Nos
25 NB 5 Nos
15 NB 1 Nos
Electronic level indicator with Tank level alarm control system, pressure transducer sensors ED display high /
12 1 Nos
low level / cabling to pump house with indicators etc.,
Exhaust pipe for Diesel engine of 150 mm dia M.S. Medium grade with mineral wool insulation with aluminum
13
sheet & residential muffler accessories.
a) 150mm dia M.S. Medium grade shall be laid above ground with aluminum gladding & structural steel supports. 18 Rmt
Supply,Installation, Testing & commissioning of Air vessel in pump room on M.S stand with necessary
14 arrangement and including the cut off, drain and air release and drain pipes to the channel in pump 1 Set
room,complete as per specification. Size 250mm dia
Above Ground piping - Supply, erection, testing and installation of MS PIPES C CLASS conforming to IS 3589 for
200NB & above and IS 1239 for 150NB & below with welded joints including cutting the pipes to correct length,
providing and welding flanges to pipe, etc as per specifications (including heavy class forged fittings of IS
standards) of the following diameters.Brackets testing to 13.5 Kg/Sq.cm hydraulic pressure after instalation.
Rate shall be inclusive of Zinc chromate primer over that 2 coats red enamel paint as per Fire authorities
15 requirement over all above ground pies and also inclusive of making hole in the wall, chasing, chipping, making
good with plastering after completion of work, pipe sleeve of suitable higher size, sealing the sleeves with glass
wool in between & fire sealant, etc. Cost of Steel supports for piping (like angles, channels, clamps, tie rods,
brackets, nuts and bolts as per details given in the drawings) shall also be included in the quoted rate.
VVendor to consider The pipe fittings shall be threaded up to 50 mm dia and Groveed / Welded type for 65 mm
dia & above. All necessary consumables like lubricant to be included in the quoted cost.
The below mentioned ratings are indicative only however the contractor shall have to select the suitable rating
breakers, switches, starters and related all the accessories based on the selected motors
Incoming
630A, 35KA, 4P MOT MCCB with all connected accessories - 1 Nos. as incomer. Incomers & Buscoupler shall
have electrically interlocked with auto manual selector switch
Instrument Panel
Digital type MFM with RS485 port - 1 NOS
Outgoing
250A TP&N 25kA THERMAL MAGNETIC MCCB with SOFT starter suitable for Electrical Driven Pumps with
ON/OFF/TRIP indicating lamps, ON/OFF push buttons and all other required accessories - 2 Nos
63A TP&N THERMAL MAGNETIC MCCB 25kA suitable for Jockey pumps with ON/OFF/TRIP indicating lamps,
ON/OFF push buttons and all other required accessories - 2 Nos
With necessary Aluminium busbars, interconnections, earthing etc., with required accessories as per the
specifications.630 Amps TPN Aluminium busbars:- All the neutral busbars shall have the same capacity of phase
busbars.
Supply installation testing and commissioning of Autostart panel for the diesel engine complete with
auto/manual switch, relay, timers, contactors, rotary switches for AC ON / DC ON, indication lamps, protective
fuses with battery charger, suitable of working on 230 V, AC, single phase, enclosure being vermin & dust proof, 1 Set
necessary alarms, different selector switches, push buttons etc. Also potential free contacts shall be provided
for connecting to the IBMS.
Battery charger with transformer with rectifier resistance DC ammeter, DC voltmeter, Trickle / booster / off
selector switch - 2 Nos.
1 set of indicating lamps for the following :
1. phase indication
2. battery charger on
3. over load relay
4. DC supply on
5. control switch on
6. Engine fails to start
7. Pump on
8. Low oil pressure
9. High water temperature
10. Auto manual selector switch
d) 1 sets of push button stations for the following :
1. Engine Start
2. Engine Stop
3. Engine - hooter ACK
4. Engine - fault reset
e) Selector switches (Engine control, mode selector)-1 No.
f) Auxiliary relays / contactors / timer for sequence operating for starting and stopping of the engine - 1 set.
g) Hooter for audio alarm (Industrial type) - 1 No.
All the components shall be housed in a common cubical made of 16 swg. M.S. sheet with required stiffeners ( if
required). The panel shall be powder coated of approved colour both inside & out side. The panel shall have
both bottom & top cable entry provisions and panel shall be mounted on Pedestal of 300 mm height.
Design, supply, laying of following size PVC/XLPE insulated outer sheathed (1100 V grade) alu. armoured
conductor cable partly laid in cable tray and partly laid in wall/ ceiling with suitable clamps. The rate shall
18
inclusive of suitable double compression glands and crimping socket for the cables. Rate shall inclusive of cable
terminations. pls refer SLD
a 3.5 Core 300 Sq.mm XLPE Aluminium armoured Cable 5 Rmt
b 3.5 Core 240 Sq.mm XLPE Aluminium armoured Cable - FOR FIRE/HYD /SPK /PUMP 45 Rmt
c 4.0 Core 16 Sq.mm XLPE Aluminium armoured Cable - FOR JOCKEY PUMP 45 Rmt
d 3.0 Core 1.5 Sq.mm PVC insulated Cu Cable 100 Rmt
19 Design, supply and laying of 50 x 6 mm GI. flat run along the cable tray 100 Rmt
Design, supply and laying of 8 gauge bare copper wire for Gland earthing, loop earthing in the existing
20 100 Rmt
surface/recessed steel conduit, DB earthing and other equipment body earthing as required.
21 Supply and laying of suitable size electrical rubber mats tested to 11KV, with grooved ISI Mark. For pump room 1 Lot
Supply, erection of following sizes GI ladder type cable rack system made out of sheet steel folded to required
22
shape with adequate number of supports. The rate shall be inclusive of suitable hanging support
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
0.00 0.00
0.00 0.00
- -
- -
- -
- -
- -
- -
- -
- -
- -
- -
Table 1
PROJECT : IIIT
LOCATION : HYDERABAD
DOCUMENT :- Obtaining Fire Noc
Obtaining Provisional Fire Noc/ Revised Provisional Fire NOC for both NAB &
i
SRIC Buildings.
Providing a check list for submitting each approval along with a thorough
write-up letter and other write-ups, and if necessary, preparing/altering all
1
basic drawings mentioned mandatory in comprehensive list of documents
required for Provisional NOC
Help the client with all necessary paperwork, including the affidavit
2 submission, along with coordination with the client's architect and PM team
and any write-ups that may be necessary.
Reviewing and, if necessary, correcting documents that the client
4
representative has prepared.
Providing a check list for submitting each approval along with a thorough
write-up letter and other write-ups, and if necessary, preparing/altering all
1
basic drawings mentioned mandatory in comprehensive list of documents
required for Final Fire NOC ( Occupancy Noc)
Help the client with all necessary paperwork, including the affidavit
2 submission, along with coordination with the client's architect and PM team
and any write-ups that may be necessary.
Reviewing and, if necessary, correcting documents that the client
4
representative has prepared.
Successfully Obtaining the Final Fire NOC ( Occupancy NOC) from Fire
7
department of hyderabad
Submission of Final Fire NOC ( Occupancy NOC) to the IIIT Hyderabad team
8
from the fire department
TOTAL
RATE/SFT AMOUNT
0
0
PROJECT : IIIT ACADEMIC BUILDING
DOCUMENT : ADDRESSABLE FIRE ALARM SYSTEM BOQ
SI.No
6
7
10
11
12
13
14
15
16
17
18
19
20
21
22
23
PROJECT : IIIT ACADEMIC BUILDING
DOCUMENT : ADDRESSABLE FIRE ALARM SYSTEM BOQ
Descriptions
Analogue Addressable Intelligent 8 loop Fire alarm control panel including loop card, provision to make
with a minimum capacity of 125 devices + 125 modules per loop, with battery back up for 48 Hrs during
normal operation and 15 minutes alarm operation, with minimum 600 Character LCD display, necessary
interface card to connect a repeater panel and all hardware & software as per specification. Panel &
Components shall be UL listed (latest edition)
SITC of Bacnet card for BMS integration for proposed FAS panels
Passive Repeater Panel with minimum 80 character display for monitoring other Panels on the network
loop with Power supply unit. Peer To Peer Networked with main panel, such that the status of the entire
system shall be available on individual Annunciator.
Graphics User Interface for Monitoring & Control of complete Fire,. The GUI based main network
software shall network with other panels on True Peer-to-Peer network. It shall be capable of graphically
representing each facility being monitored with floor plans and icons depicting the actual locations of the
various systems.. It shall have the facility to change the sensitivity of any detector. The software shall be
capable of monitoring 200 Nodes with 100 MB baud Transmission rate on Fibre Optics Network and 12
MB baud Transmission on cable and 2,50,000 network , GUI shall be capable of monitoring & controlling
and mapping the unlimited fire points. The Graphic workstation shall act as an independent node
communicating on the peer to peer network and shall not be dependant on the Fire Panel CPU for
operation. Failure of Fire Panel CPU shall not result in failure of GUI. Software shall be suitable for total
numbers of Fire alarm panels
Supply Installation Testing & Commissioning of Multi sensor detector (photo+heat) with base,powder
coated back box and other accessories as required and Detectors shall be UL listed, - (ABOVE FALSE
CEILING & FALSE FLOOR). Detectors shall be UL listed 268 7th edition
Supply Installation Testing & Commissioning of Multi sensor detector (photo+heat) with base and other
accessories as required and Detectors shall be UL listed, - (BELOW FALSE CEILING). Detectors shall be UL
listed 268 7th edition
Supply Installation Testing & Commissioning of Analog Addressable Smoke Detector with programmable
for timed automatic sensitivity selection with Standard base, powder coated backbox and other
accessories as required and Detectors shall be UL Listed. (TRUE CEILING/ABOVE FALSE CEILING).
Detectors shall be UL listed 268 7th edition
Supply Installation Testing & Commissioning of Analog Addressable Smoke Detector with programmable
for timed automatic sensitivity selection with Standard base and other accessories as required and
Detectors shall be UL Listed. (BELOW FALSE CEILING). Detectors shall be UL listed 268 7th edition
Supply Installation Testing & Commissioning of heat detector with base, Junction box and other
accessories as required and Detectors shall be UL listed,Detectors shall be UL listed 268 7th edition
Supply, installation, fixing, testing and commissioning of Addressable four-wire 70mtr coverage Beam
smoke detector with Single-ended, reflective design, Six user selectable sensitivity levels, Optional integral
NFPA 72 sensitivity test feature, Digital display for easy alignment, suitable for operating in temperature
range of (-) 22°F to (+) 131°F (UL Listed).It should provided with necessary Power supply units, fixing
accessories.As per the specifications
Supply, installation, fixing, testing and commissioning of Analogue Addressable Monitor module with
back box(1.6mm thick RED colour) operating at 24V DC, 2A, rated at 230V, provided with DPDT contact.
FLOW SWITCH
ASD#0,
WLD#
GRP#0
FIRE DOOR#10 with required fixing accessories
Supply, installation, fixing, testing and commissioning of Analogue Addressable Control module with
back box (1.6mm thick RED colour) operating at 24V DC, 2A, rated at 230V, provided with DPDT
contact,with required fixing accessories
Access Control #5
PA INTEGRATION#5
Hooter#25
Supply, installation, fixing, testing and commissioning of Analogue Addressable Control relay module
with back box(1.6mm thick RED colour) operating at 24V DC, 2A, rated at 230V, provided with DPDT
contact. with required fixing accessories, AC/AHU TRIPPING/ Pressurization fans/Lift
Addressable Electronic Hooter cum Strobe ceiling mounted. The hooters shall be made of ABS plastic, and
have a DB level of 65dbA and a multi tone facility. Addressable Control Module shall be fitted in a junction
box.
SITC of Addressable Manual call point having an integrally mounted addressable module that monitors
and reports contact status. (PULL TYPE) with back box(1.6mm thick RED colour) along with required fixing
accessories. The device shall have an LED which shall blink in normal state & get steady on activation to
monitor the heath status of the device.
2C x 1.5 mm2, Stranded Copper conductor,Type A ST1 PVC insulated,Armoured FRLS CU Cable 1100 V as
per IS 1554, with GI saddle spacers every 0.3 mtr with Single compression Cable Glands,ABS Junction
Boxes (wherever required), terminals,Ferruling complete.
Supplying, installing, testing and commissioning of approved make FRLS PVC conduits on ceiling / wall /
floor etc. complete with accessories like, Junction boxes, Collars, Bends, clamps, saddles etc. (for MCP)
25 mm dia.
Supply and laying of MS Powder coated Trunking 300 x 50 mm x 1.6mm with cover & fixing suppports
etc as required (Cable dressing for Fire & PA panel )
Supply and laying of GI enclosed raceway 300 x 50 mm x 1.6mm with cover & fixing suppports etc as
required (Cable dressing inside the shaft )
SITC of PSU for hooters & AHU tripping (inclusive of Battery ckt & battery)
TOTAL
AMC Cost
Charges for Comprehensive Annual Maintenance Charges for a period of 5 years from the end of
Guarantee period. Vendor to note that all important security upgrades to the software necesiated due to
isues in the software itself or due to upgrades made to OS shall be provided without any additional cost.
I year
II year
III year
IV year
V year
Unit GF 1F 2F 3F 4F Total Qty SUPPLY
RATE INR
Lot 1 1
Lot 1
Nos 1
Lot 1
Nos 1
Nos 4 2 2 2 18 28
Nos 1 1 1 18 21
Nos 25 45 20 20 25 135
Nos 2 2 2 2 8
Nos 5 5
Nos 25 45 20 25 45 160
Nos 9 8 7 7 8 39
Nos 2 2 2 2 2 10
Nos 7 7 7 6 7 34
Nos 10 10 8 8 8 44
Nos 25 25 25 20 25 120
Nos 13 11 8 8 10 50
Rmt 39 33 24 24 30 150
Rmt 25 25
Rmt 5 5 5 5 20
Set 5 5 5 4 5 24
Lot 1
Lot 1
Lot 1
Lot 1
Lot 1
ERECTION
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
- -
Makes
NOTIFIER /EDWARDS/SIMPLEX/SCHNEIDER/SIEMENS
CERBERUS PRO
NOTIFIER /EDWARDS/SIMPLEX/SCHNEIDER/SIEMENS
CERBERUS PRO
NOTIFIER /EDWARDS/SIMPLEX/SCHNEIDER/SIEMENS
CERBERUS PRO
NOTIFIER /EDWARDS/SIMPLEX/SCHNEIDER/SIEMENS
CERBERUS PRO
HP/ DELL
NOTIFIER /EDWARDS/SIMPLEX/SCHNEIDER/SIEMENS
CERBERUS
NOTIFIER /EDWARDS/SIMPLEX/SCHNEIDER/SIEMENS
CERBERUS
NOTIFIER /EDWARDS/SIMPLEX/SCHNEIDER/SIEMENS
CERBERUS
NOTIFIER /EDWARDS/SIMPLEX/SCHNEIDER/SIEMENS
CERBERUS
NOTIFIER /EDWARDS/SIMPLEX/SCHNEIDER/SIEMENS
CERBERUS
NOTIFIER /EDWARDS/SIMPLEX/SCHNEIDER/SIEMENS
CERBERUS
RAVEL/C SYSTEM/AGNI
NOTIFIER /EDWARDS/SIMPLEX/SCHNEIDER/SIEMENS
CERBERUS
NOTIFIER /EDWARDS/SIMPLEX/SCHNEIDER/SIEMENS
CERBERUS
NOTIFIER /EDWARDS/SIMPLEX/SCHNEIDER/SIEMENS
CERBERUS
NOTIFIER /EDWARDS/SIMPLEX/SCHNEIDER/SIEMENS
CERBERUS
NOTIFIER /EDWARDS/SIMPLEX/SCHNEIDER/SIEMENS
CERBERUS
NOTIFIER /EDWARDS/SIMPLEX/SCHNEIDER/SIEMENS
CERBERUS
VIP/ PRECISION/ASTRA/ANCHOR
REPUTED
REPUTED
Battery : Panasonic/Exide/Amaron
PSU : CTEC/CSYSTEM/INSYIN
PROJECT : IIIT ACADEMIC BUILDING
DOCUMENT : PUBLIC ADDRESS SYSTEM BOQ
SI.No Descriptions
SITC of 6W RMS False Ceiling Mount Speakers with inbuilt 100V Line Matching Transformer,
wide opening angle, optimized for music & speech applications with mounting clamps as per
1
specifications
SITC of 6W RMS True Ceiling Mount Speakers with inbuilt 100V Line Matching Transformer,
wide opening angle, optimized for music & speech applications with powder coated back box,
2 supports as per specifications
Speakers shall have the tappings at 1.5/3/6 watts
SITC of 6 W Wall Mounted box Speakers with line matching transformers as specified as per
3
specifications
SITC of 15W bidirectional wall mount wooden speaker with Frequency response of 200Hz to
4 15Khz with SPL sensitivity of 88db @ 1mtr and tapping of 15W/7.5W/3.75W as specified as
per specifications
SITC of System Controller 6 zone controller with 500w inbuilt amplifier complete with
5 Microprocessor based, Dual Tone Control for Speech & Music, with automatic
announcement incase of fire, etc.
2C x 1.5 mm2, Stranded Copper conductor,Type A ST1 PVC insulated,Armoured FRLS Cable
12 1100 V as per IS 1554, with GI saddle spacers every 0.3 mtr with Single compression Cable
Glands,ABS Junction Boxes (wherever required), terminals,Ferruling complete.
TOTAL
AMC Cost
Charges for Comprehensive Annual Maintenance Charges for a period of 5 years from the end
of Guarantee period. Vendor to note that all important security upgrades to the software
necesiated due to isues in the software itself or due to upgrades made to OS shall be provided
without any additional cost.
I year
II year
III year
IV year
V year
Unit GF 1F 2F 3F 4F Total Qty SUPPLY
RATE INR
Nos 25 45 15 20 40 145
Nos 90 55 70 70 65 350
Nos 5 5 5 5 5 25
Nos 15 15
Nos 1 1
Nos 1 1
Nos 1
Nos 1
Nos 1
Nos 1 1 1 3
Nos 2 2 1 1 1 7
Nos 1 1
Nos 1 1
Lot 1 1
Lot
Lot
Lot
Lot
Lot
ERECTION
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
- -
Makes
BOSCH/HONEYWELL
Philips / Sony / LG / Samsung
VALL RACK / MASS RACK
PROJECT : IIIT ACADEMIC BUILDING
DOCUMENT : SIGNAGE SYSTEM BOQ
SI.No Descriptions Unit GF 1F
"FIRE EXIT " (BATTERY BACKED LED SIGNAGE) - size 150 x 300mm
1 Nos 7 4
SINGLE SIDE
" Emergency Exit Signages - (Autoglow type) size 150 x 300mm - double
2 Nos 45 45
side with suspension chains (SS)
" Hydrant - Autoglow, with suspension chains (Autoglo signages, size 150
5 Nos 2 2
x 300 - double side with suspension chains (SS)
TOTAL
AMC Cost
Charges for Comprehensive Annual Maintenance Charges for a period of
5 years from the end of Guarantee period.
I year Lot
II year Lot
III year Lot
IV year Lot
V year Lot
2F 3F 4F Total Qty SUPPLY ERECTION
RATE INR AMOUNT INR RATE INR AMOUNT INR
2 2 2 17 0 0
50 50 50 240 0 0
23 23 28 131 0 0
8 8 10 50 0 0
2 2 2 10 0 0
4 4 4 24 0 0
- -
Makes
PROLITE/AUTOGLOW/Technoware
PROLITE/AUTOGLOW/Technoware
PROLITE/AUTOGLOW/Technoware
PROLITE/AUTOGLOW/Technoware
PROLITE/AUTOGLOW/Technoware
PROLITE/AUTOGLOW/Technoware
PROJECT : IIIT ACADEMIC BUILDING
DOCUMENT : FIRE EXTINGUISHER SYSTEM BOQ
SI.No Descriptions Unit
CO2 type Fire Extinguisher ISI marked confirming to IS:15683 latest. Capacity 4.5 Kg.
Complete with delivery hose horn, squeeze grip release valve, locking
arrangement,operating temperature -30°C to +55°C, supplied with body bearing IS
1 7285 mark and approved by CCoE tested at 250 kgf/cm2., fitted with ISI marked & Nos
CCoE approved valve as per IS 3224. CO2 Gas as per IS: 15222. externally painted
with PO Red Shade No. 538 of IS 5, operation manual and floor stand or Wall Mount
Bracket including accessories as required as per site condition
Powder Fire Extinguisher (Stored Pressure type) (Powder pressurized with dry
nitrogen gas at 15 bar.) capacity: 4kg duly ISI marked conforming to IS:
15683:2006/latest, with IS 14609 ISI marked ABC powder complete with squeeze
2 grip release valve, discharge pipe, locking arrangement, pressure gauge, operation Nos
manual,Body Hydrotested at 35 bar, Operating temperature -30°C to +55°C, external
epoxy powder coating with PO Red Shade No. 538 of IS 5, and floor stand or Wall
Mount Bracket including accessories as required as per site condition
Clean Agent (Stored Pressure) Type Fire Extinguisher Complete with squeeze grip
release valve, locking arrangement, pressure gauge, operation manual, bracket with
3 Nos
two screw and sleeve filled with FE36/HFC- 236 FA . Complete in all respect, Capacity
4 Kg. with Floor mounting bracket with four leg or Wall Mount Bracket. ZERO ODC
FE36 Automatic ceiling Mounted Clean agent Extinguisher - 5 Kg with Ceiling mount
5 accessories including nozzle(57 deg), pressure guage. ISI approved - UPS, Nos
Battery,Server room & Hub room
Wet chemical stored pressure 6Ltr capacity including accessories, pressure guage
6 Nos
and floor mounting accessories (kitchen - preparation area)
Fire buckets round bottom type enamel painted, white inside & Red out side and
7 Nos
Letter "FIRE" in black out side and handle with mounting bracket.
Fire bucket stand fabricated by MS angles to install 4 Nos. of buckets including rain
8 Nos
top cover .
TOTAL
AMC Cost
Charges for Comprehensive Annual Maintenance Charges for a period of 5 years
from the end of Guarantee period.
I year Lot
II year Lot
III year Lot
IV year Lot
V year Lot
GF 1F 2F 3F 4F Total Qty SUPPLY
RATE INR AMOUNT INR
1 1 3 3 3 11 0
30 25 20 20 25 120 0
1 0
1 0
1 2 2 1 6 0
1 0
1 0
1 0
-
ERECTION
Makes
RATE INR AMOUNT INR
0 MINIMAX/KANEX
0 MINIMAX/KANEX
0 MINIMAX/KANEX
0 MINIMAX/KANEX
0 MINIMAX/KANEX
0 MINIMAX/KANEX
0 Fabricated
0 Fabricated
-
PROJECT : IIIT , SIRC Building
DOCUMENT : ADDRESSABLE FIRE ALARM SYSTEM BOQ
SI.No
7
8
10
11
12
13
14
15
16
17
18
19
20
21
22
23
PROJECT : IIIT , SIRC Building
DOCUMENT : ADDRESSABLE FIRE ALARM SYSTEM BOQ
Descriptions
Analogue Addressable Intelligent 3 loop Fire alarm control panel including loop card, provision to make with a
minimum capacity of 125 devices + 125 modules per loop, with battery back up for 48 Hrs during normal operation
and 15 minutes alarm operation, with minimum 600 Character LCD display, necessary interface card to connect a
repeater panel and all hardware & software as per specification. Panel & Components shall be UL listed (latest
edition)
SITC of Bacnet card for BMS integration for proposed FAS panels
Passive Repeater Panel with minimum 80 character display for monitoring other Panels on the network loop with
Power supply unit. Peer To Peer Networked with main panel, such that the status of the entire system shall be
available on individual Annunciator.
Graphics User Interface for Monitoring & Control of complete Fire,. The GUI based main network software shall
network with other panels on True Peer-to-Peer network. It shall be capable of graphically representing each facility
being monitored with floor plans and icons depicting the actual locations of the various systems.. It shall have the
facility to change the sensitivity of any detector. The software shall be capable of monitoring 200 Nodes with 100
MB baud Transmission rate on Fibre Optics Network and 12 MB baud Transmission on cable and 2,50,000 network ,
GUI shall be capable of monitoring & controlling and mapping the unlimited fire points. The Graphic workstation
shall act as an independent node communicating on the peer to peer network and shall not be dependant on the
Fire Panel CPU for operation. Failure of Fire Panel CPU shall not result in failure of GUI.
Supply Installation Testing & Commissioning of Multi sensor detector (photo+heat) with base,powder coated back
box and other accessories as required and Detectors shall be UL listed, - (ABOVE FALSE CEILING & FALSE FLOOR).
Detectors shall be UL listed 268 7th edition
Supply Installation Testing & Commissioning of Multi sensor detector (photo+heat) with base and other
accessories as required and Detectors shall be UL listed, - (BELOW FALSE CEILING). Detectors shall be UL listed 268
7th edition
Supply Installation Testing & Commissioning of Analog Addressable Smoke Detector with programmable for timed
automatic sensitivity selection with Standard base, powder coated backbox and other accessories as required and
Detectors shall be UL Listed. (TRUE CEILING/ABOVE FALSE CEILING). Detectors shall be UL listed 268 7th edition
Supply Installation Testing & Commissioning of Analog Addressable Smoke Detector with programmable for timed
automatic sensitivity selection with Standard base and other accessories as required and Detectors shall be UL
Listed. (BELOW FALSE CEILING). Detectors shall be UL listed 268 7th edition
Supply Installation Testing & Commissioning of heat detector with base, Junction box and other accessories as
required and Detectors shall be UL listed,Detectors shall be UL listed 268 7th edition
Supply, installation, fixing, testing and commissioning of Addressable four-wire 70mtr coverage Beam smoke
detector with Single-ended, reflective design, Six user selectable sensitivity levels, Optional integral NFPA 72
sensitivity test feature, Digital display for easy alignment, suitable for operating in temperature range of (-) 22°F to
(+) 131°F (UL Listed).It should provided with necessary Power supply units, fixing accessories.As per the
specifications
Analogue Addressable Fault isolator module capable of monitoring shorted loop circuit and automatically restore
communications when shorted conditions are corrected. (FIM's are used for every 20 detectors/devices)
Supply, installation, fixing, testing and commissioning of Analogue Addressable Monitor module with back
box(1.6mm thick RED colour) operating at 24V DC, 2A, rated at 230V, provided with DPDT contact.
FLOW SWITCH
ASD#0,
WLD#
GRP#0
FIRE DOOR#0 with required fixing accessories
Supply, installation, fixing, testing and commissioning of Analogue Addressable Control module with back box
(1.6mm thick RED colour) operating at 24V DC, 2A, rated at 230V, provided with DPDT contact,with required fixing
accessories
Access Control #3
PA INTEGRATION#3
Hooter#7
Supply, installation, fixing, testing and commissioning of Analogue Addressable Control relay module with back
box(1.6mm thick RED colour) operating at 24V DC, 2A, rated at 230V, provided with DPDT contact. with required
fixing accessories, AC/AHU TRIPPING/ Pressurization fans/Lift
Addressable Electronic Hooter cum Strobe ceiling mounted. The hooters shall be made of ABS plastic, and have a
DB level of 65dbA and a multi tone facility. Addressable Control Module shall be fitted in a junction box.
SITC of Addressable Manual call point having an integrally mounted addressable module that monitors and reports
contact status. (PULL TYPE) with back box(1.6mm thick RED colour) along with required fixing accessories. The
device shall have an LED which shall blink in normal state & get steady on activation to monitor the heath status of
the device.
2C x 1.5 mm2, Stranded Copper conductor,Type A ST1 PVC insulated,Armoured FRLS CU Cable 1100 V as per IS
1554, with GI saddle spacers every 0.3 mtr with Single compression Cable Glands,ABS Junction Boxes (wherever
required), terminals,Ferruling complete.
Supplying, installing, testing and commissioning of approved make FRLS PVC conduits on ceiling / wall / floor etc.
complete with accessories like, Junction boxes, Collars, Bends, clamps, saddles etc. (for MCP)
25 mm dia.
Supply and laying of MS Powder coated Trunking 300 x 50 mm x 1.6mm with cover & fixing suppports etc as
required (Cable dressing for Fire & PA panel )
Supply and laying of GI enclosed raceway 300 x 50 mm x 1.6mm with cover & fixing suppports etc as required
(Cable dressing inside the shaft )
SITC of PSU for hooters & AHU tripping (inclusive of Battery ckt & battery)
TOTAL
AMC Cost
Charges for Comprehensive Annual Maintenance Charges for a period of 5 years from the end of Guarantee period.
Vendor to note that all important security upgrades to the software necesiated due to isues in the software itself or
due to upgrades made to OS shall be provided without any additional cost.
I year
II year
III year
IV year
V year
Unit GF MF 1F Total Qty SUPPLY ERECTION
Lot 1 1 0
Lot 1 0
Nos 1 0
Lot 1 0
Nos 1 0
Nos 1 0
Nos 1 0
Nos 65 20 35 120 0
Nos 65 20 35 120 0
Nos 1 0
Nos 2 2 0
Nos 65 20 35 120 0
Nos 7 3 4 14 0
Nos 2 2 2 6 0
Nos 5 4 4 13 0
Nos 5 5 5 15 0
Nos 11 6 6 23 0
Nos 8 4 4 16 0
Rmt 24 12 12 48 0
Rmt 10 10 0
Rmt 5 5 10 0
Set 3 2 2 8 0
Lot
Lot
Lot
Lot
Lot
AMOUNT INR
0
0
0
0
-
Makes
HP/ DELL
RAVEL/C SYSTEM/AGNI
VIP/ PRECISION/ASTRA/ANCHOR
FABRICATED
FABRICATED
Battery : Panasonic/Exide/Amaron
PSU : CTEC/CSYSTEM/INSYIN
PROJECT : IIIT , SIRC Building
DOCUMENT : PUBLIC ADDRESS SYSTEM BOQ
SITC of 6W RMS False Ceiling Mount Speakers with inbuilt 100V Line Matching
Transformer, wide opening angle, optimized for music & speech applications with
1 Nos
mounting clamps as per specifications
SITC of 6W RMS True Ceiling Mount Speakers with inbuilt 100V Line Matching
Transformer, wide opening angle, optimized for music & speech applications with
2 powder coated back box, supports as per specifications Nos
Speakers shall have the tappings at 1.5/3/6 watts
SITC of 6 W Wall Mounted box Speakers with line matching transformers as specified
3 Nos
as per specifications
SITC of 15W bidirectional wall mount wooden speaker with Frequency response of
4 200Hz to 15Khz with SPL sensitivity of 88db @ 1mtr and tapping of 15W/7.5W/3.75W Nos
as specified as per specifications
SITC of System Controller 6 zone controller with 500w inbuilt amplifier complete with
5 Microprocessor based, Dual Tone Control for Speech & Music, with automatic Nos
announcement incase of fire, etc.
TOTAL
AMC Cost
Charges for Comprehensive Annual Maintenance Charges for a period of 5 years from
the end of Guarantee period. Vendor to note that all important security upgrades to
the software necesiated due to isues in the software itself or due to upgrades made to
OS shall be provided without any additional cost.
I year Lot
II year Lot
III year Lot
IV year Lot
V year Lot
GF MF 1F Total Qty SUPPLY ERECTION
65 20 35 120 0
1 0
2 2 2 6 0
4 4 0
1 1 0
0 0
1 1 0
0 0
0 0
1 1 0
1 1 0
1 1 0
1.00
1.00
1.00
1.00
1.00
Makes
AMOUNT INR
-
PROJECT : IIIT , SIRC Building
DOCUMENT : SIGNAGE SYSTEM BOQ
SI.No Descriptions Unit GF MF
1 "FIRE EXIT " (BATTERY BACKED LED SIGNAGE) - SINGLE SIDE Nos 7 2
" Emergency Exit Signages - (Autoglow type) size 150 x 300mm - double
2 Nos 20 15
side with suspension chains (SS)
" MCP Signages - Autoglow, with suspension chains (Autoglo signages, size
4 Nos 8 4
150 x 300 - double side with suspension chains (SS)
" Hydrant - Autoglow, with suspension chains (Autoglo signages, size 150 x
5 Nos 2 2
300 - double side with suspension chains (SS)
TOTAL
AMC Cost
Charges for Comprehensive Annual Maintenance Charges for a period of 5
years from the end of Guarantee period.
I year Lot
II year Lot
III year Lot
IV year Lot
V year Lot
1F Total Qty SUPPLY ERECTION
RATE INR AMOUNT INR RATE INR AMOUNT INR
2 11 0 0
20 55 0 0
7 26 0 0
4 16 0 0
2 6 0 0
2 7 0 0
- -
Makes
PROLITE/AUTOGLOW/Technoware
PROLITE/AUTOGLOW/Technoware
PROLITE/AUTOGLOW/Technoware
PROLITE/AUTOGLOW/Technoware
PROLITE/AUTOGLOW/Technoware
PROLITE/AUTOGLOW/Technoware
PROJECT : IIIT , SIRC Building
DOCUMENT : FIRE EXTINGUISHER SYSTEM BOQ
SI.No Descriptions
CO2 type Fire Extinguisher ISI marked confirming to IS:15683 latest. Capacity 4.5 Kg.
Complete with delivery hose horn, squeeze grip release valve, locking
arrangement,operating temperature -30°C to +55°C, supplied with body bearing IS 7285
1 mark and approved by CCoE tested at 250 kgf/cm2., fitted with ISI marked & CCoE approved
valve as per IS 3224. CO2 Gas as per IS: 15222. externally painted with PO Red Shade No.
538 of IS 5, operation manual and floor stand or Wall Mount Bracket including accessories
as required as per site condition
Powder Fire Extinguisher (Stored Pressure type) (Powder pressurized with dry nitrogen gas
at 15 bar.) capacity: 4kg duly ISI marked conforming to IS: 15683:2006/latest, with IS 14609
ISI marked ABC powder complete with squeeze grip release valve, discharge pipe, locking
2 arrangement, pressure gauge, operation manual,Body Hydrotested at 35 bar, Operating
temperature -30°C to +55°C, external epoxy powder coating with PO Red Shade No. 538 of
IS 5, and floor stand or Wall Mount Bracket including accessories as required as per site
condition
Clean Agent (Stored Pressure) Type Fire Extinguisher Complete with squeeze grip release
valve, locking arrangement, pressure gauge, operation manual, bracket with two screw and
3
sleeve filled with FE36/HFC- 236 FA . Complete in all respect, Capacity 4 Kg. with Floor
mounting bracket with four leg or Wall Mount Bracket. ZERO ODC
FE36 Automatic ceiling Mounted Clean agent Extinguisher - 10 Kg with Ceiling mount
4 accessories including nozzle(57 deg), pressure guage. ISI approved - UPS, Battery,Server
room & Hub room
FE36 Automatic ceiling Mounted Clean agent Extinguisher - 5 Kg with Ceiling mount
5 accessories including nozzle(57 deg), pressure guage. ISI approved - UPS, Battery,Server
room & Hub room
Wet chemical stored pressure 6Ltr capacity including accessories, pressure guage and floor
6
mounting accessories (kitchen - preparation area)
Fire buckets round bottom type enamel painted, white inside & Red out side and Letter
7
"FIRE" in black out side and handle with mounting bracket.
Fire bucket stand fabricated by MS angles to install 4 Nos. of buckets including rain top
8
cover .
TOTAL
AMC Cost
Charges for Comprehensive Annual Maintenance Charges for a period of 5 years from the
end of Guarantee period.
I year
II year
III year
IV year
V year
Unit GF MF 1F Total Qty SUPPLY ERECTION
RATE INR AMOUNT INR RATE INR
Nos 2 2 2 6 0
Nos 15 4 7 26 0
Nos 1 1 2 0
Nos 1 1 2 0
Nos 1 1 2 0
Nos 1 1 2 0
Nos 1 1 2 0
Nos 1 1 2 0
Lot
Lot
Lot
Lot
Lot
ERECTION
Makes
AMOUNT INR
0 MINIMAX/KANEX
0 MINIMAX/KANEX
0 MINIMAX/KANEX
0 MINIMAX/KANEX
0 MINIMAX/KANEX
0 MINIMAX/KANEX