EL Series (1kVA-3kVA)

Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

THE HIGH-FREQUENCY TRANSFORMER-

LESS STATIC CONVERTER UPS


EL Series High Frequency On-line UPS (1 kVA
& 3 kVA) configuration

Krykard EL SERIES UPS (1 kVA & 3 kVA)

No Compromise
UPS

Wide Frequency Range High-efficiency & Frequency


Wide input frequency range of 40 - 70Hz Multiple functions settable via LCD: output
50 / 60Hz and 60/ 50Hz frequency conversion voltage, EOD, auto-start, bypass mode, ECO
feature mode and Frequency Conversion mode

Full Protection & Efficiency After Sales Support

Protection against short-circuit, over load, over No questions asked ‘guarantee


temp, battery discharge protection, fan testing Wide service network covering 90 + locations
Linear load derating for input voltages under across India
176V to reduce battery usage Service response within 6 hours in service
towns and within 24 hours in the same State

KRYKARD is India’s leading power and energy management brand


Contact us
with more than 400,000 installations of Power Conditioners and over +91 95000 97966
150,000 installations of Portable and Panel Load Managers for more info

+91 95000 97966 www.atandra.in [email protected]


KRYKARD EL Series UPS

About Krykard EL Series UPS


Extensive Service
KRYKARD brings you a well-engineered Online UPS backed by Centres across India
timely service to deliver reliable perfect minimum downtime.
It is loaded with extra protection features like Multiple
functions settable via LCD: output voltage, EOD, auto-start,
bypass mode, ECO mode and Frequency Conversion mode..
KRYKARD EL Series UPS is available in various options like
SNMP card, RS485 card, 12 A charger (3 kVA only), 1 no.15 A
socket in place of 4 nos. 5 A socket for 3 kVA. It has the best-
in-class multiple functions settable via LCD: output voltage,
EOD, auto-start, bypass mode, ECO mode and Frequency
Conversion mode.

Key Features
Static Converter for automatic data processing machines
High-frequency online double conversion
DSP (Digital signal processors) control
Active power factor correction (APFC), input power factor up to 0.99
Output power factor @0.9
Wide input operating range of 160Vac to 280Vac
Extended input operating range of 120Vac to 300Vac for partial loading
Wide input frequency range of 40 - 70Hz
50 / 60Hz and 60/ 50Hz frequency conversion feature
Cold start available – can switch on the UPS on battery mode in the absence of mains
Rear ventilation and temperature dependent variable fan speed
Multiple functions settable via LCD: output voltage, EOD, auto-start, bypass mode, ECO mode and
Frequency Conversion mode
Multiple communication options: RS232 (standard), SNMP, RS485 (optional)
Output Sockets : 2 x 5A sockets for 1kVA, 4 x 5A for 3kVA

Available Options
SNMP card
RS485 card
12A charger (3kVA only)
1 no.15A socket in place of 4 nos. 5A socket for 3kVA

High Efficiency Flexible Multiple Display


Configuration Options

Atandra Energy Private Limited I No.5, Kumaran Street, Pazhavanthangal, Chennai, Tamil Nadu - 600 114
(ISO 9001:2015 Certified Company)
KRYKARD is a registered trademark owned by Atandra Energy Pvt. Ltd.
Revision: Jan 2022. Specifications are subject to change without prior notice.
KRYKARD EL Series UPS

SPECIFICATION
MODEL EL-01 ELB-01 EL-03 ELB-03

Rated Capacity 1kVA / 900W 3kVA / 2700W

INPUT

Input Wiring Single-Phase Three-wire (1Φ + N + E)

Rated Voltage 208 / 220 / 230 / 240Vac

120 ~ 160Vac (linear derating between 50% and 100% load), 160 ~ 280Vac (No derating),
Voltage Range
280 ~ 300 Vac (derating 50%)

Rated Frequency 50 / 60 Hz (auto-sensing)

Frequency Range 40 ~ 70Hz

Power Factor ≥ 0.99

Bypass Voltage Range -25% ~ +15% (settable)

Total Harmonic Distortion (THDi) ≤ 6%

OUTPUT

Output Wiring Single-phase Three-wire (1Φ + N + PE)

Rated Voltage 208 / 220 / 230 / 240Vac (settable via LCD)

Voltage Regulation ±1%

Frequency 45 ~ 55Hz or 55 ~ 65Hz in Synchronized range, 50 / 60Hz ± 0.1% in Battery mode

Waveform Sinusoidal

Power Factor 0.9

Total Harmonic Distortion (THDv) ≤ 2% (linear load); ≤ 5% (non-linear load)

Crest Factor 3:1

Overload 105% ~ 125% for 1 min, 126% ~ 150% for 30 s, >150% for 300 ms

BATTERIES

Charging Current (max.) 36 V 36 V 96 V 96 V

No. of Batteries (Inbuilt) _ 3 x 7 Ah _ 8 x 7 Ah

Charging Current (max.) 6A 1A 6A 1A

Recharge Time 3hrs depends on capacity of battery 8hrs depends on capacity of battery

SYSTEM

≥ 90% (Mains mode), ≥ 85% (Battery mode), ≥ 92% (Mains mode), ≥ 87% (Battery mode),
Efficiency
≥ 95% (ECO mode) ≥ 97% (ECO mode)

Protections Short-circuit, Over load, Over Temp, Battery discharge protection, Fan testing protection

Max. no. of Parallel Connections _

Communications Standard configuration: RS232; Optional configuration: SNMP , RS485, dry contacts

Display LCD + LED

OTHERS

Operating Temperature 0°C ~ 40°C

Storage Temperature -25°C ~ 55°C (without battery)

Relative Humidity 0% ~ 95% (non-condensing)

Altitude ≤ 1000 m; derating 1% for each additional 100 m

IP Rating IP 20

Noise Level at 1m ≤ 50 dB

Dimensions (W × D × H) (mm) 144 x 336 x 214 144 x 317 x 214 191 x 418 x 335 191 x 464 x 335

Weight (kg) 6 13 11 32

Atandra Energy Private Limited I No.5, Kumaran Street, Pazhavanthangal, Chennai, Tamil Nadu - 600 114
(ISO 9001:2015 Certified Company)
KRYKARD is a registered trademark owned by Atandra Energy Pvt. Ltd.
Revision: Jan 2022. Specifications are subject to change without prior notice.

You might also like