Model KCM

Circular Diffusers

INTRODUCTION
KMC Circular Diffusers have a circular cone with
elegant styling to provide maximum air diffusion
efficiency.

APPLICATION
Recommended for supply air, constant or variable
air volume heating, cooling, or ventilating

Efficient air distribution in cooling applications at


temperature differentials as high as 16° C

360° air pattern delivery maintains horizontal


pattern with or without ceiling effect

Expanding cone design provides excellent


horizontal air discharge preventing drafts in the
occupied zone

PRODUCT FEATURES
Removable inner core permits easy installation and
access to duct

Optional Butterfly Type Volume control damper

Powder Coated to RAL 9010 as standard

Custom colors available on request

Selection Procedure
Selections can be made by means of a straight
read-off from the “Performance Data” for the
selected model.

• Determine the air volume flow rate per outlet.

• Establish the required Throw (Refer Notes for


Throw Pattern)

• Select the diffuser based on required Air flow


rate against the limiting pressure drop and sound
level requirements.

DIMENSION IN MM
Nominal Dia ØA ØB
150 158 243
200 198 285
250 245 332
300 315 398
350 352 438
400 398 482
450 448 560

Product Selection Check List


• Select Unit size based on specified inlet diameter.
• Select volume control accessory, it desired.
• Select Finish.

*In the interest of product development, KMC reserves the right to make changes without notice.
w ww.kmcq ata r.co m 1 Company
Khalid Manufacturing
Model KCM
Circular Diffusers

Performance Data
Neck
Duct Area, m2

2.0 2.5 3.0 4.0 5.0 6.0 7.0 8.0 9.0 10.0
Neck Size

Velocity
Nominal
ø mm

Velocity
2.5 5 5 10 15 22.5 30 40 50 62.5
Pressure

CMH 109 136 163 218 272 326 367 422 476 530
Ps 7.5 12.5 20 25 42.5 52.5 67.5 87.5 112.5 140
150 0.015
NC <20 <20 <20 23 29 34 37 41 45 48
Throw 0.3 0.6 1.2 0.6 0.9 1.5 0.6 0.9 2.1 0.9 1.2 2.7 1.2 1.5 3.4 1.2 2.1 4.0 1.5 2.1 4.6 1.8 2.4 4.9 1.8 2.7 5.2 2.1 3.4 5.5
CMH 190 231 286 381 476 571 666 762 857 952
Ps 5 7.5 10 17.5 30 42.5 57.5 72.5 92.5 115
200 0.026
NC <20 <20 <20 20 26 31 36 39 43 45
Throw 0.6 0.9 1.5 0.6 0.9 2.1 0.9 1.2 2.4 1.2 1.5 3.4 1.5 2.1 4.3 1.5 2.4 4.9 1.8 3.0 5.8 2.1 3.4 6.7 2.4 3.7 7.0 2.7 4.3 7.3
CMH 299 367 449 598 748 884 1034 1183 1333 1482
Ps 2.5 5 7.5 12.5 20 27.5 37.5 47.5 60 75
250 0.041
NC <20 <20 <20 21 27 31 36 39 43 46
Throw 0.6 0.9 2.1 0.9 1.2 2.4 0.9 1.5 3.0 1.5 2.1 4.3 1.8 2.4 5.2 2.1 3.0 6.1 2.4 3.7 7.0 2.7 4.0 8.2 3.0 4.6 8.8 3.4 5.2 9.1
CMH 422 530 639 857 1074 1278 1496 1714 1918 2135
Ps 5 7.5 10 17.5 27.5 37.5 52.5 67.5 85 105
300 0.058
NC <20 <20 <20 27 33 38 42 46 49 52
Throw 0.9 1.2 2.4 0.9 1.5 3.0 1.2 1.8 3.7 1.8 2.4 5.2 2.1 3.0 6.4 2.4 3.7 7.6 3.0 4.3 8.8 3.4 5.2 10.1 3.7 5.8 10.7 4.3 6.4 11.0
CMH 666 830 1006 1333 1673 1999 2339 2666 3006 3332
Ps 2.5 5 7.5 12.5 20 27.5 37.5 47.5 60 75
350 0.089
NC <20 <20 21 28 34 39 44 47 51 53
Throw 0.9 1.5 3.0 1.2 1.8 4.0 1.5 2.4 4.6 2.1 3.0 6.1 2.7 4.0 7.9 3.0 4.6 9.5 3.7 5.5 11.0 4.3 6.1 12.5 4.6 7.0 13.1 5.2 7.6 14.0
NC 762 952 1142 1523 1904 2285 2666 3046 3250 3332
CMH (L) 7.5 12.5 20 25 37.5 47.5 60 70 87.5 115
400 0.117
Throw (L) <20 <20 21 28 34 39 44 47 51 53
CMH 0.9 1.5 3.0 1.2 1.8 4.0 1.5 2.4 4.6 2.1 3.0 6.1 2.7 4.0 7.9 3.0 4.6 8.5 3.7 5.5 9.8 4.3 6.1 10.7 4.6 7.0 11.6 5.2 7.6 13.4
NC 966 1197 1442 1918 2407 2883 3359 3849 4325 4801
CMH (L) 7.5 12.5 20 25 37.5 47.5 65 85 107.5 132.5
450 0.132
Throw (L) <20 <20 23 30 37 42 46 50 53 56
Throw (L) 1.5 2.1 3.7 1.8 3.0 4.6 2.4 3.7 5.8 2.7 4.3 7.6 3.0 4.6 9.5 3.7 5.8 10.7 4.3 6.7 12.2 4.9 7.6 13.1 5.8 8.5 14.0 6.4 9.5 14.6

Notes :
• Neck velocity in m/s, meters per second Throw
• The numbers shown are throw distances, in meters, measured
Test Standard along the jet trajectory axis relating to terminal velocities of 0.75
• ANSI / ASHRAE standard 70 m/s, 0.5 m/s & 0.25 m/s and include a surface effect
• Isothermal conditions • Terminal velocity is the air speed, in meters per second, measured
• Non-uniform air flow into diffusers increase sound levels, in the supply air stream.
operating pressures, and can distort the air distribution pattern • For exposed duct installations, throws are 70% of the table values
into the space above.

Sound Levels Pressure


• NC is noise criteria curve that will not be exceeded at the operating • Ps represents static pressure, Pa
point. This is determined by assuming a 10dB (ref: 10-12 watts) • Pt total pressure can be calculated by adding the Velocity pressure
room attenuation that is subtracted from the power levels in each and Static pressure (Ps), in Pa
of the 2nd thru 7th octave bands • All pressures are stated and calculated in Pa
Typical Specification
Contractor shall furnish & install KMC Model KDJ Jet Diffuser Up to four outlets may be attached to one mounting panel permitting
air outlets of the jet discharge and/or diffusing type at each point multi-directional, as well as mixed jet and diffused patterns, from
indicated on the plans. The core of the outlet shall be rotatable so one location. (Optional) The outlet shall be directly mounted at the
as to deliver air in a jet pattern or in a diffused pattern. The throw of end of the round spiral duct where shown.
the diffused pattern shall be approximately half that of the jet pattern
The outlet and mounting panel shall be constructed from steel or
at similar terminal velocities. Jet type diffusers without spread
aluminum as indicated.
capability are not acceptable.
Finishing shall be KMC standard Colour (RAL9010) or colour as
In either position, the axis of air flow may be varied up to 30° from
scheduled or selected by the Architect.
the straight-forward in a full 360° arc. The outlet shall be attached
to a mounting panel with mounting screws permitting 360° rotation.

*In the interest of product development, KMC reserves the right to make changes without notice.

Khalid Manufacturing Company w w w.km cq a ta r.co m