Products Catalog

Varistors (ZNR Surge Absorber)

2023.6
Varistors (ZNR Surge Absorber) INDEX
Type Series Part number Page

Safety and Legal Matters to Be Observed 1

“ZNR” Transient / Surge Absorbers 2

Products system 3

Matters to Be Observed When Using This Product (D-type : E series) 4

Standard products ERZE□□A□□□ 8

Leads cut type ERZE□□A(B)□□□CS 23


E series Taping specifications ERZE□□E(F)□□□ 24

Application note for safety standards / Marking contents /


28
D type Performance characteristics / Minimum quantity

Standard products ERZE□□A□□□S1 31

Leads cut type ERZE□□A□□□SC 34


E-S1 series
Application note for safety standards / Marking contents /
41
Performance characteristics / Minimum quantity

Matters to Be Observed When Using This Product (D-type : V series / SMD-type : HF・VF series) 44

Standard products ERZV□□D□□□ 49

Leads cut type ERZV□□D(V)□□□CS/C1 69


D type V series Taping specifications ERZV□□D(V)□□□ 70

Application note for safety standards / Marking contents /


74
Performance characteristics / Minimum quantity

Performance characteristics /
HF series ERZHF□□□□□ 77
Recommendation land size
SMD type Performance characteristics /
VF series Recommendation land size / ERZVF□□□□□ 80
Minimum quantity

Matters to Be Observed When Using This Product (E / CK / SC-type) 85

SC type Minimum quantity ERZVS□□□□□□ 88

E type Performance characteristics / Minimum quantity ERZC□□EK□□□(Y) 90

Application note for safety standards /


CK type ERZC□□CK□□□ 96
Performance characteristics / Minimum quantity

Matters to Be Observed When Using This Product (P, J, G-type / Arrestor box / E, J-type for thyristor) 101

P type Minimum quantity ERZA□□PK□□□ 103

J type Minimum quantity ERZA□□JK□□□ 105

G type Minimum quantity ERZA□□GS(K)□□□ 108

Surge absorber units Minimum quantity ERZA 110

For thyristor E type ERZC□□EK□□□P


Minimum quantity 112
protection J type ERZU□□JP□□□
Safety and Legal Matters to Be Observed

Safety and Legal Matters to Be Observed

Product specifications and applications


■ Please be advised that this product and product specifications are subject to change without notice for
improvement purposes. Therefore, please request and confirm the latest delivery specifications that explain
the specifications in detail before the final design, or purchase or use of the product, regardless of the
application. In addition, do not use this product in any way that deviates from the contents of the company's
delivery specifications.
■ Unless otherwise specified in this catalog or the delivery specifications, this product is intended for use in
general electronic equipment (AV products, home appliances, commercial equipment, office equipment,
information and communication equipment, etc.).
When this product is used for the following special cases, please separately discuss the delivery specifications
suited to each application with the company. These include applications requiring special quality and reliability,
wherein their failures or malfunctions may directly threaten human life or cause harm to the human body
(e.g.: space/aircraft equipment, transportation/traffic equipment, combustion equipment, medical equipment,
disaster prevention/crime prevention equipment, safety equipment, etc.).

Safety design and product evaluation


■ Please ensure safety through protection circuits, redundant circuits, etc., in the customer's system design so
that a defect in our company's product will not endanger human life or cause other serious damage.
■ This catalog shows the quality and performance of individual parts. The durability of parts varies depending on
the usage environment and conditions. Therefore, please ensure to evaluate and confirm the state of each part
after it has been mounted in your product in the actual operating environment before use.
If you have any doubts about the safety of this product, then please notify us immediately, and be sure to conduct
a technical review including the above protection circuits and redundant circuits at your company.

Laws / Regulations / Intellectual property


■ The transportation of dangerous goods as designated by UN numbers, UN classifications, etc., does not apply
to this product. In addition, when exporting products, product specifications, and technical information described
in this catalog, please comply with the laws and regulations of the countries to which the products are exported,
especially those concerning security export control.
■ Each model of this product complies with the RoHS Directive (Restriction of the use of hazardous substances in
electrical and electronic equipment) (2011/65/EU and (EU) 2015/863). The date of compliance with the RoHS
Directive and REACH Regulation varies depending on the product model.
Further, if you are using product models in stock and are not sure whether or not they comply with the RoHS
Directive or REACH Regulation, please contact us by selecting "Sales Inquiry" from the inquiry form.
■ During the manufacturing process of this product and any of its components and materials to be used,
Panasonic does not intentionally use ozone-depleting substances stipulated in the Montreal Protocol and
specific bromine-based flame retardants such as PBBs (Poly-Brominated Biphenyls) / PBDEs (Poly-Brominated
Diphenyl Ethers). In addition, the materials used in this product are all listed as existing chemical substances
based on the Act on the Regulation of Manufacture and Evaluation of Chemical Substances.
■ With regard to the disposal of this product, please confirm the disposal method in each country and region
where it is incorporated into your company's product and used.
■ The technical information contained in this catalog is intended to show only typical operation and application
circuit examples of this product. This catalog does not guarantee that such information does not infringe upon
the intellectual property rights of Panasonic or any third party, nor imply that the license of such rights has been
granted.

Panasonic Industry will assume no liability whatsoever if the use of our company's
products deviates from the contents of this catalog or does not comply with the
precautions. Please be advised of these restrictions.

30-Jun-23
1
Varistors (ZNR Surge Absorber)

“ZNR” Transient / Surge absorbers


ZNRs are zinc-oxide nonlinear resistors whose resistance changes as a function of the applied voltage.
These basic characteristics of ZNR express by varistor voltage and clamping voltage (or voltage ratio).
The ZNR utilizes a ceramic element composed of zinc oxide and several kinds of metal oxide additives that have
been sintered at relatively high temperature.
The ZNR has a bilateral and symmetrical V-I characteristics similar to back-to-back zener diode and unparalleled
large peak current capability so it can be used for absorption of transient voltage, suppression of pulse noise and
as an arrester element and circuit voltage stabilization.

Explanation of technical terms


1. Voltage-current characteristics 2. Maximum peak current
Figure 1 shows voltage-current characteristics of Specification which specified how much surge current
ZNR. The axis of abscissas is logarithm of current surge absorber can endure is maximum peak
and the axis of ordinates is logarithm of voltage. current.
Characteristics, voltage value at 1mA(principle) is This characteristic expresses a current value having
used, calling varistor voltage. In case of surge standard wave form shown in figure 2.
absorber which utilizes at large current region In case of different waveform from the standard one,
because of voltage at specified current is used, the specifications shall be determined by reffering to
calling clamping voltage. impulse life ratings.

100
Voltage log

90
Maximum Clamping Voltage
Varistor voltage

Current (%)

Max. 50
Nom.
Min.

Maximum Leakage Current 10


0
8 μs Time
10-3 A Current log 20 μs

Fig.1. Example of V-I Characteristic of ZNR Fig.2.Standard Impulse Current Waveform (8/20 μs)

Note: *ZNR “Zinc Oxide Nonlinear Resistor” is a trade mark of voltage dependent resistor elements by
Panasonic. ZNR is in some cases named Metal Oxide Varistor “MOV”
3. Clamping voltage
Varistors have an abitity to limit a high voltage surge like lightning.
We call this limited voltage as “Clamping Voltage”. “Clamping Voltage” is measured by voltage between two
therminals using standard impulse current waveform (8/20 μs) shown in fig.2.
To avoid an exothermic influence.

Lightning Voltage Clumping Voltage by ZNR


Voltage

Voltage

Time Time

Fig. 3 Example of impressing pulse and clamping Voltage

Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
2
Varistors (ZNR Surge Absorber)

Products system

Large surge current and


D type ●Varistor voltage:200 to 1100 V
energy handling capability
E/E-S1 ●Maximum peak current:600 to 7000 A
for absorbing transient
series (at 8/20 μs)
overvoltage

Standard type with radial ●Varistor voltage :18 to 1800 V


D type
leads for general surge ●Maximum peak current:125 to 7000 A
V series
protect applications ( at 8/20 μs)

For Automotive (DC12 V) ●Varistor voltage:20 to 23.2 V


SMD type Meet for Load Damp Surge 27 V±20 %
HF series Compact size SMD High ●Maximum surge:JASO A-1
Reliability 70 V 1 time

Surface mount type with ●Varistor voltage:22 to 470 V


SMD type
protective coating so as to high ●Maximum peak current:125 to 600 A
VF series
level reliability (at 8/20 μs)

For incorporation in a ●Varistor voltage:200 to 950 V


surge protective device ●Maximum peak current:In 20 kA,
SC type
corresponding to the JIS C 5381- Imax. 40 kA
1 (at 8/20 μs)

For an application in industrial ●Varistor voltage:200 to 1100 V


E type
electric or electronic equipment ●Maximum peak current:5 to 25 kA
CK type
under heavy duty (at 8/20 μs)
Varistors
(ZNR Surge
Absorber)
Plug-in type with deterioration ●Varistor voltage:250 to 1000 V
P type indicator. For application to ●Maximum peak current:5000 A
industrial equipment (at 8/20 μs)

●Varistor voltage:560 to 1250 V


Stack-type for heavy surge
●Maximum peak current:80 to 320 kA
J type energy application (High
(at 4/10 μs)
power induced load and so on)
●Energy:5000 to 40000 J

●Varistor voltage:5 to 17 kV
For protection to switching
●Maximum peak current:5 to 10 kA
G type surge of high voltage (3.3, 6.6 kV)
(at 8/20 μs)
equipment
●Energy:1300 to 2600 J

Surge
Surge absorber with connected ●Varistor voltage:12 to 100 V
absorber
ZNRs and circuit breaker in box ●Maximum peak current:5000 A
units

Surge
●Varistor voltage:510 to 2500 V
absorbers Thristor protection against
●Impulse life:40 to 210 A
for switching surge of transformer
(2 ms, 104 times)
thyristor

Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
3
Matters to Be Observed When Using This Product

Matters to Be Observed When Using This Product


(D-type : E series)

Safety measures
An abnormal state of the D-type / E series varistor (ZNR surge absorber, hereinafter "the product" or "the surge absorber")
that results from a problem with service conditions (materials used, the surrounding environment, power conditions, circuit
conditions, etc.) may cause a fire accident, electric shock accident, burn accident, or product failure. Matters to note when
handling this product will hereinafter be described. What is described below should be checked sufficiently before the
product is used.

■ Confirming rated capabilities


Use the surge absorber within the range of its rated capabilities. Each type of surge absorber has specified rated
capabilities including a maximum allowable circuit voltage, a surge current tolerance, an energy tolerance, an impulse
lifespan (surge lifespan), average pulse power, and a service temperature. Using the surge absorber under severe
service conditions that are beyond the rated capabilities causes degraded performance of the surge absorber or
destruction of a circuit element, which may lead to smoke generation, ignition, etc.

■ Take the following measures in order to avoid an accident caused by expected phenomenon.

(1) Destruction of the surge absorber may scatter its fractured pieces around. To protect other elements from these
pieces, set product in a case or shield it with a cover.
(2) Do not place the surge absorber near combustible materials (vinyl cable, resin mold, etc.). If avoiding the vicinity
of combustible materials is difficult, protect the combustible material with an incombustible cover.
(3) Surge absorber placed between lines
When the surge absorber is placed between lines, connect a normal type current fuse in series with the surge
absorber.
* See "Current fuse" in the "Circuit design and circuit board design" section.
(4) Surge absorber placed between a line and the ground
① When the surge absorber is placed between a line and the ground, even if the surge absorber short-circuits,
ground resistance will remain in the section between the line and the ground, leaving a possibility that the
current fuse won’t blow, in which case the outer sheath resin of the surge absorber may generate smoke or
ignite due to current flow. To prevent such a case, place an earth leakage breaker in a location closer to the
power supply than the surge absorber. When not using an earth leakage breaker, use a current fuse and
temperature fuse in series with each other.
* See Table 1 in the "Circuit design and circuit board design" section.
② When the surge absorber is placed between a live part and a metal case, it may cause electric shock if the
surge absorber short-circuits. To avoid this, ground the metal case or shield it to prevent direct contact with the
metal case.

■ In case the surge absorber should short-circuit and generate smoke or ignite, immediately cut off current flow
to the surge absorber.

■ Rated voltage for UL certification, etc.


To allow the surge absorber to meet leak current requirements, etc., a maximum allowable circuit voltage and rated
voltage are specified for the surge absorber.
When applying for UL certification, etc. of a device equipped with a surge absorber, ensure the working voltage of the
device does not exceed the rated voltage of the surge absorber.

■ An unexpected sharp rise in the working voltage, an incoming excessive surge, etc., may cause the surge absorber to
generate smoke or ignite.
In such a case, fire spreading through the device should be prevented to avoid expanded damage. To achieve this,
take a multi-protection measure, such as adopting fire-resistant materials that make up the outer shell components
and structural materials.

Use environments and cleaning conditions


■ Do not use the surge absorber in an outdoor environment where the surge absorber is exposed to sunlight.

■ Do not use the surge absorber in which direct sunlight hits the surge absorber or near a heating element where the
temperature of the surge absorber would rise above its working temperature.

■ Do not use the surge absorber in a place where the surge absorber is exposed to wind or rain or a highly humid place
where steam is emitted or dew concentrates.

30-Jun-23
4
Matters to Be Observed When Using This Product

■ Do not use the surge absorber in a place filled with dust or salt, in an atmosphere contaminated with a corrosive gas,
etc., or in liquids such as water, oil, chemical, or organic solvents.

■ Do not wash the surge absorber with a solvent (thinner, acetone, etc.) that damages the outer sheath resin.

Response to anomalies and handling conditions


Be careful not to drop the surge absorber on the floor, etc. The product is likely to suffer mechanical or electrical damage
when dropped on the floor. Avoid using such a product.

Circuit design and circuit board design


Meet the following requirements. Not following the requirements can result in a shorter lifespan of the surge absorber or its
failure.

■ Choose a surge absorber whose maximum allowable circuit voltage has a margin relative to the maximum voltage range
including source voltage fluctuations.
* See Table 1 in the "Circuit design and circuit board design" section.

■ When surges are applied intermittently to the surge absorber at short intervals (when pulses of voltages are applied in a
noise simulator test, etc.), make sure that the surge power does not exceed the maximum average pulse power of the surge
absorber.

■ The product numbers of recommended surge absorbers to choose are shown in Table 1.

(1) The case of placing the surge absorber between lines


When the source voltage is expected to rise temporarily due to unbalanced single-wire loads in a three-phase three-wire
connection configuration, a short circuit between a voltage line and a neutral line, loss of the neutral line, or resonance of
a capacitive load caused by switching on/off, use a surge absorber (varistor) indicated by "*" in Table 1.
(2) The case of placing the surge absorber between a line and the ground
Line-to-ground voltage may rise with a single-wire ground fault, etc. Use a recommended surge absorber in Table 1 that
is different from the surge absorber placed between lines. When the device is subjected to an insulation resistance test
(500 V DC), use a D-type surge absorber indicated by "**" in Table 1.
According to "Electrical Appliance Technical Standards" based on the Electrical Appliance and Material Safety Act, when
using a varistor voltage which would fail the insulation performance test, the surge absorber may be removed from the
device when being subjected to the test, depending on circuit test conditions.
* See attached table 4, appendix 4, "Electrical Appliance Technical Standards" based on the Electrical Appliance and
Material Safety Act.

■ Current fuse

(1) Select a surge absorber and the rated current for a current fuse to be used in a manner shown in the following table.
Confirm that no secondary accident arises when the surge absorber in an actual circuit breaks. Selected rated currents of
current fuses shown in the following table are exemplary one and may vary depending on circuit conditions used. Confirm
the rated current by a test, etc., before using the current fuse.

<Rated currents of current fuses for the D-type / E/E-S1 series surge absorbers>
Standard
product number ERZE05A□□□ ERZE07A□□□ ERZE08A□□□ ERZE10A□□□ ERZE11A□□□ ERZE14A□□□
Rating
Current
5 A max. 7 A max. 7 A max. 10 A max. 10 A max. 10 A max.

* Use the rated voltage of the current fuse that corresponds to the circuit voltage of a circuit including the current fuse.

(2) Recommended parts where fuses are connected are shown in Table 1. When a load current to a protected device is so
large as to exceed the rated current of the fuse, however, connect the fuse in a location shown in the following diagram.

Current fuse
Power supply Protected
device
ZNR

■ Temperature fuse
When connecting the surge absorber to a temperature fuse, choose a connection method and a temperature fuse that allow
fine thermal coupling between the surge absorber and the temperature fuse.

30-Jun-23
5
Matters to Be Observed When Using This Product

Table 1 Application example of the product (ordinary application example)

Surge absorber placed between lines Surge absorber placed between a line and the ground

DC DC
Single-phase AC Single-phase AC
Current fuse ZNR1
Current fuse ZNR1 L
L
Protected
Protected device
device N
N ZNR2

Temperature
Thermal coupling fuse
Connection

Three-phase AC Three-phase AC

Current fuse

Current fuse ZNR3 ZNR3 ZNR3


Protected
device
Protected ZNR3
device
ZNR4
ZNR3 Temperature
Thermal coupling fuse

Power supply Power supply


ZNR Nominal varistor voltage ZNR Nominal varistor voltage
voltage [AC] voltage [AC]
Varistor voltage selection

100 V 201 to 361* 471


120 V 241 to 431* 100 V 511
ZNR 1 200 V 471 to 621* 220 V 621
ZNR 3 220 V 471 to 621* ZNR 2 821 or higher**
240 V 511、 621* ZNR 4 511
230 V
380 V 751、 821* 621*
240 V
821 or higher**
380 V 112**
* Choose the element size while taking surge conditions into consideration.

30-Jun-23
6
Matters to Be Observed When Using This Product

Processing conditions
■ Do not apply vibration, impact (drop impact, etc.), or pressure strong enough to crack the outer sheath resin or absorber
body of the surge absorber.

■ When coating the surge absorber with a resin or embedding it in a resin mold, avoid using a resin that degrades the
surge absorber.

■ Do not bend or apply a force to the lead of a D-type surge absorber close to the outer sheath resin.

Mounting and storage conditions


■ When soldering the surge absorber, follow recommended soldering conditions shown in the following table so that
solder or the insulation material making up the surge absorber is not melted.

■ When making holes for mounting the surge absorber on the board, check the dimensions of the holes on the board,
referencing the central point of the interval between the leads.
Because the overall dimensional tolerance is large, forming the holes with high precision requires careful processing.

Soldering method Recommended conditions Mater to note


Flow soldering
A D-type surge absorber should not be soldered
D-type (solder bath immersion 260 ℃, 10 seconds or less
by reflow soldering.
method)

Note 1: Soldering the surge absorber under soldering conditions different from the recommended soldering
conditions requires extra checking to ensure it won’t cause any problems.
Additional soldering is allowed only once. It must be done within 5 seconds, with the soldering iron
temperature kept at 400 ℃ or lower.
Note 2: A temperature profile may include a large error, depending on the measurement method used.
Be careful in such cases.
Note 3: Board temperatures vary depending on the sizes of boards and mounting densities. Confirm the
temperature for each type of board.

<Recommended soldering temperature profile>

Flow soldering (solder bath immersion method)

Soldering part Normal temperature


Preheating part 120 seconds or less
Preheating part Cooling part to 130 ℃
Temperature (°C)

Soldering part 260 ℃ or less 10 seconds or less


Gradual cooling
Cooling part
(cooling under the normal temperature)

Time

■ Do not keep the product in a high-temperature or high-humidity condition. Keep the surge absorber in a room with
a temperature of 40 ℃ or lower and a relative humidity of 75% or lower and use the surge absorber within two years of
storage. Check the solderability of a surge absorber stored for a long period (two years or more) before using the surge
absorber.

■ Keep the surge absorber in a place where no corrosive gas atmosphere (hydrogen sulfide, sulfurous acid, chlorine,
ammonia, etc.) is present.

■ Keep the surge absorber in a place where the surge absorber is protected from direct sunlight, dew concentration, etc.

30-Jun-23
7
Varistors (ZNR Surge Absorber)
D type
E series

Varistors (ZNR Surge Absorber), Series E, Type D features


large surge current and energy handling capability for
absorbing transient overvoltage in a compact size.

Features
●Large withstanding surge current capability in compact sizes
●Large “Energy Handling Capability” absorbing transient overvoltages in compact sizes
●Wide range of varistor voltages
●RoHS compliant

Recommended applications
●Transistor, diode, IC, thyristor or triac semiconductor protection
●Surge protection in consumer electronic equipment
●Surge protection in communication, measuring or controller electronics
●Surge protection in electronic home appliances, gas or petroleum appliances

Applicable standards
●UL1449 (VZCA2/UL, VZCA8/C-UL)
●VDE IEC61051-1,-2,-2-2,IEC60950-1 Annex.Q, IEC62368-1 G8.2
●CQC (GB/T10193, GB/T10194, GB4943.1, GB8898)
Refer to "Standard Products" , and "Application Note for Safety Standards" , for the details.

Refer to "Standard Products" , and "Application Note for Safety Standards" , for the details.

■As for handling precautions and minimum quantity / Packing unit


please see related information.

Explanation of part numbers


1 2 3 4 5 6 7 8 9 10 11 12

E R Z E
Product code Design No.

Code Series Lead configuration Norminal varistor voltage


E05 E5 Code Configuration Packaging
The first two digits are significant
E07 E7 A Straight lead Bulk figures and the third one denotes the
number of zeros following.
E08 E8 B*1 Crimped lead Bulk
*2
E10 E10 E Straight lead Taped
*2
E11 E11 F Crimped lead Taped
E14 E14 *1: Excluding E14, only the lead cut
*2: Excluding E14

Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
8
D type / E series
Reference guide to standard products
Varistor Clamping Maximum
Applicable Maximum
voltage voltage peak current
standards allowable voltage
Part No. at 1 mA at 8/20 μs at 8/20 μs (A)

Acrms DC
Type name Approvals (V) max.(V) lp (A) 1time 2times
(V) (V)
ERZE05A201 E201 ○☆◇ 340 10 1200 600
ERZE07A201 E7201 ○☆◇ 340 25 2500 1250
ERZE08A201 E8201 ○☆◇ 200 340 25 3500 2500
130 170
ERZE10A201 E10201 ○☆◇ (185 to 225) 340 50 4500 3000
ERZE11A201 E11201 ○☆★◇◆ 340 50 6000 5000
ERZE14A201 E14201 ○☆★◇◆ 340 100 10000 7000
ERZE05A221 E221 ○☆◇ 360 10 1200 600
ERZE07A221 E7221 ○☆◇ 360 25 2500 1250
ERZE08A221 E8221 ○☆◇ 220 360 25 3500 2500
140 180
ERZE10A221 E10221 ○☆◇ (198 to 242) 360 50 4500 3000
ERZE11A221 E11221 ○☆★◇◆ 360 50 6000 5000
ERZE14A221 E14221 ○☆★◇◆ 360 100 10000 7000
ERZE05A241 E241 ○☆◇ 395 10 1200 600
ERZE07A241 E7241 ○☆◇ 395 25 2500 1250
ERZE08A241 E8241 ○☆◇ 240 395 25 3500 2500
150 200
ERZE10A241 E10241 ○☆◇ (216 to 264) 395 50 4500 3000
ERZE11A241 E11241 ○☆★◇◆ 395 50 6000 5000
ERZE14A241 E14241 ○☆★◇◆ 395 100 10000 7000
ERZE05A271 E271 ○☆◇ 455 10 1200 600
ERZE07A271 E7271 ○☆◇ 455 25 2500 1250
ERZE08A271 E8271 ○☆◇ 270 455 25 3500 2500
175 225
ERZE10A271 E10271 ○☆◇ (247 to 303) 455 50 4500 3000
ERZE11A271 E11271 ○☆★◇◆ 455 50 6000 5000
ERZE14A271 E14271 ○☆★◇◆ 455 100 10000 7000
ERZE05A331 E331 ○☆◇ 545 10 1200 600
ERZE07A331 E7331 ○☆◇ 545 25 2500 1250
ERZE08A331 E8331 ○☆◇ 330 545 25 3500 2500
210 270
ERZE10A331 E10331 ○☆◇ (297 to 363) 545 50 4500 3000
ERZE11A331 E11331 ○☆★◇◆ 545 50 6000 4500
ERZE14A331 E14331 ○☆★◇◆ 545 100 10000 6500
ERZE05A361 E361 ○☆◇ 595 10 1200 600
ERZE07A361 E7361 ○☆◇ 595 25 2500 1250
ERZE08A361 E8361 ○☆◇ 360 595 25 3500 2500
230 300
ERZE10A361 E10361 ○☆◇ (324 to 396) 595 50 4500 3000
ERZE11A361 E11361 ○☆★◇◆ 595 50 6000 4500
ERZE14A361 E14361 ○☆★◇◆ 595 100 10000 6500
ERZE05A391 E391 ○☆◇ 650 10 1200 600
ERZE07A391 E7391 ○☆◇ 650 25 2500 1250
ERZE08A391 E8391 ○☆◇ 390 650 25 3500 2500
250 320
ERZE10A391 E10391 ○☆◇ (351 to 429) 650 50 4500 3000
ERZE11A391 E11391 ○☆★◇◆ 650 50 6000 4500
ERZE14A391 E14391 ○☆★◇◆ 650 100 10000 6500
ERZE05A431 E431 ○☆◇ 710 10 1200 600
ERZE07A431 E7431 ○☆◇ 710 25 2500 1250
ERZE08A431 E8431 ○☆◇ 430 710 25 3500 2500
275 350
ERZE10A431 E10431 ○☆◇ (387 to 473) 710 50 4500 3000
ERZE11A431 E11431 ○☆★◇◆ 710 50 6000 4500
ERZE14A431 E14431 ○☆★◇◆ 710 100 10000 6500

○: UL1449 (VZCA2/UL, VZCA8/C-UL), ☆ : VDE (IEC61051-1, -2, -2-2) ★ : VDE (IEC60950-1 Annex.Q, IEC62368-1 G8.2 ),
◇: CQC (GB/T10193, GB/T10194), ◆ : CQC (GB4943.1, GB8898)
※Approval number (File No.) of safety regulations are subject to revision without notice. Ask factory for a copy of the latest file No.

Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
9
D type / E series
Reference guide to standard products
Varistor Clamping Maximum
Applicable Maximum
voltage voltage peak current
standards allowable voltage
Part No. at 1 mA at 8/20 μs at 8/20 μs (A)

Acrms DC
Type name Approvals (V) max.(V) lp (A) 1time 2times
(V) (V)
ERZE05A471 E471 ○☆◇ 775 10 1200 600
ERZE07A471 E7471 ○☆◇ 775 25 2500 1250
ERZE08A471 E8471 ○☆★◇◆ 470 775 25 3500 2500
300 385
ERZE10A471 E10471 ○☆★◇◆ (423 to 517) 775 50 4500 3000
ERZE11A471 E11471 ○☆★◇◆ 775 50 6000 4500
ERZE14A471 E14471 ○☆★◇◆ 775 100 10000 6500
ERZE07A511 E7511 ○☆◇ 845 25 2500 1250
ERZE08A511 E8511 ○☆★◇◆ 845 25 3500 2500
510
ERZE10A511 E10511 ○☆★◇◆ 320 410 845 50 4500 3000
(459 to 561)
ERZE11A511 E11511 ○☆★◇◆ 845 50 6000 4500
ERZE14A511 E14511 ○☆★◇◆ 845 100 10000 6500
ERZE07A561 E7561 ○☆◇ 930 25 2500 1250
ERZE08A561 E8561 ○☆★◇◆ 930 25 3500 2500
560
ERZE10A561 E10561 ○☆★◇◆ 350 450 930 50 4500 3000
(504 to 616)
ERZE11A561 E11561 ○☆★◇◆ 930 50 6000 4500
ERZE14A561 E14561 ○☆★◇◆ 930 100 10000 6500
ERZE07A621 E7621 ○☆◇ 1025 25 2500 1250
ERZE08A621 E8621 ○☆★◇◆ 1025 25 3500 2500
620
ERZE10A621 E10621 ○☆★◇◆ 385 505 1025 50 4500 3000
(558 to 682)
ERZE11A621 E11621 ○☆★◇◆ 1025 50 5000 4500
ERZE14A621 E14621 ○☆★◇◆ 1025 100 7500 6500
ERZE08A681 E8681 ○☆★◇◆ 1120 25 3500 2500
ERZE10A681 E10681 ○☆★◇◆ 680 1120 50 4500 3000
420 560
ERZE11A681 E11681 ○☆★◇◆ (612 to 748) 1120 50 5000 4500
ERZE14A681 E14681 ○☆★◇◆ 1120 100 7500 6500
ERZE08A751 E8751 ○☆★◇◆ 1240 25 3500 2500
ERZE10A751 E10751 ○☆★◇◆ 750 1240 50 4500 3000
460 615
ERZE11A751 E11751 ○☆★◇◆ (675 to 825) 1240 50 5000 4500
ERZE14A751 E14751 ○☆★◇◆ 1240 100 7500 6500
ERZE10A821 E10821 ○☆★◇◆ 1355 50 4500 3000
820
ERZE11A821 E11821 ○☆★◇◆ 510 670 1355 50 5000 4500
(738 to 902)
ERZE14A821 E14821 ○☆★◇◆ 1355 100 7500 6500
ERZE10A911 E10911 ○☆★◇◆ 1500 50 4500 3000
910
ERZE11A911 E11911 ○☆★◇◆ 550 745 1500 50 5000 4500
(819 to 1001)
ERZE14A911 E14911 ○☆★◇◆ 1500 100 7500 6500
ERZE10A102 E10102 ○☆★◇◆ 1650 50 4500 3000
1000
ERZE11A102 E11102 ○☆★◇◆ 625 825 1650 50 5000 4500
(900 to 1100)
ERZE14A102 E14102 ○☆★◇◆ 1650 100 7500 6500
ERZE10A112 E10112 ○☆★◇◆ 1815 50 4500 3000
1100
ERZE11A112 E11112 ○☆★◇◆ 680 895 1815 50 5000 4500
(990 to 1210)
ERZE14A112 E14112 ○☆★◇◆ 1815 100 7500 6500

○: UL1449 (VZCA2/UL, VZCA8/C-UL), ☆ : VDE (IEC61051-1, -2, -2-2) ★ : VDE (IEC60950-1 Annex.Q, IEC62368-1 G8.2 ),
◇: CQC (GB/T10193, GB/T10194), ◆ : CQC (GB4943.1, GB8898)
※Approval number (File No.) of safety regulations are subject to revision without notice. Ask factory for a copy of the latest file No.

Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
10
D type / E5 series
Ratings and characteristics
●Operating temperature range : ‒40 to 85 ℃ ●Storage temperature range : ‒40 to 125 ℃

Maximum
Varistor Clamping Maximum energy peak current Capacitance
Maximum Rated
voltage voltage (8/20 μs) (max.)
allowable voltage power
Part No. at 1 mA (max.)**lp at 1 kHz

(10/1000 μs) (2 ms) 1 time 2 times


ACrms DC
(V) (V) (W) (J) (J) (A) (A) (pF)
(V) (V)

ERZE05A201 200(185 to 225) 130 170 340 0.25 13 9.5 1200 600 200
ERZE05A221 220(198 to 242) 140 180 360 0.25 14 10 1200 600 190
ERZE05A241 240(216 to 264) 150 200 395 0.25 15 11 1200 600 170
ERZE05A271 270(247 to 303) 175 225 455 0.25 18 13 1200 600 150
ERZE05A331 330(297 to 363) 210 270 545 0.25 21 15 1200 600 130
ERZE05A361 360(324 to 396) 230 300 595 0.25 23 17 1200 600 130
ERZE05A391 390(351 to 429) 250 320 650 0.25 26 19 1200 600 130
ERZE05A431 430(387 to 473) 275 350 710 0.25 29 21 1200 600 120
ERZE05A471 470(423 to 517) 300 385 775 0.25 32 23 1200 600 100
✽Ip Measuring current of clamping voltage : 10 A

Dimensions in mm (not to scale)


Unit : mm
Part No. D max. T max. F±1.0 A max. L±1.0
D
ERZE05A201 7.0 4.8 5.0 10.0 2.1 T
ERZE05A221 7.0 4.9 5.0 10.0 2.3
ERZE05A241 7.0 5.0 5.0 10.0 2.4
A
ERZE05A271 7.0 5.2 5.0 10.0 2.5
ERZE05A331 7.0 5.5 5.0 10.0 2.9 L

ERZE05A361 7.0 5.8 5.0 10.0 3.1


20.0 min.

L
ERZE05A391 7.0 5.9 5.0 10.0 3.2 F

ERZE05A431 7.0 6.1 5.0 10.0 3.3 ø0.6 F


ERZE05A471 7.0 6.3 5.0 10.0 3.5

Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
11
D type / E5 series
Typical characteristics
Voltage vs. Current Impulse Derating (Relation between
impulse width and impulse current multiple)

ERZE05A201 to ERZE05A471 ERZE05A201 to ERZE05A471

Max.Leakage 10000
Current
Max.Clamping Voltage 2 times:5 min. interval
2000 up to 10 times:2 min. interval
up to 106 times : 10 sec. interval
471
431
471 391
431 361
331 1000
1000 391
271
900 361
241
800 221
700 201
600

Impulse Current(A)
500
100
400

300
Voltage(V)

200
10

331
100
221
90
80 1
70
60 Test current waveform
50 10–6 to 10–3 A: Direct current
10–1 to 104 A: 8/20 μs

40
30 0.1
10-6 10-5 10-4 10-3 10-2 10-1 100 101 102 103 104 105 20 100 1000 10000

Current(A) Impulse Width(μs)

Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
12
D type / E7 series
Ratings and characteristics
●Operating temperature range : ‒40 to 85 ℃ ●Storage temperature range : ‒40 to 125 ℃

Maximum
Varistor Clamping Maximum energy peak current Capacitance
Maximum Rated
voltage voltage (8/20 μs) (max.)
allowable voltage power
Part No. at 1 mA (max.)**lp at 1 kHz

(10/1000 μs) (2 ms) 1 time 2 times


ACrms DC
(V) (V) (W) (J) (J) (A) (A) (pF)
(V) (V)

ERZE07A201 200(185 to 225) 130 170 340 0.3 26 19 2500 1250 360
ERZE07A221 220(198 to 242) 140 180 360 0.3 30 22 2500 1250 350
ERZE07A241 240(216 to 264) 150 200 395 0.3 33 24 2500 1250 340
ERZE07A271 270(247 to 303) 175 225 455 0.3 39 28 2500 1250 310
ERZE07A331 330(297 to 363) 210 270 545 0.3 44 32 2500 1250 280
ERZE07A361 360(324 to 396) 230 300 595 0.3 50 36 2500 1250 260
ERZE07A391 390(351 to 429) 250 320 650 0.3 53 38 2500 1250 240
ERZE07A431 430(387 to 473) 275 350 710 0.3 60 43 2500 1250 210
ERZE07A471 470(423 to 517) 300 385 775 0.3 65 47 2500 1250 170
ERZE07A511 510(459 to 561) 320 410 845 0.3 70 50 2500 1250 140
ERZE07A561 560(504 to 616) 350 450 930 0.3 75 55 2500 1250 140
ERZE07A621 620(558 to 682) 385 505 1025 0.3 80 60 2500 1250 135
✽Ip Measuring current of clamping voltage : 25 A

Dimensions in mm (not to scale)


Unit : mm

Part No. D max. T max. F±1.0 A max. L±1.0


ERZE07A201 9.0 5.3 7.5 12.5 2.1
ERZE07A221 9.0 5.4 7.5 12.5 2.3
ERZE07A241 9.0 5.5 7.5 12.5 2.4
D
ERZE07A271 9.0 5.7 7.5 12.5 2.5 T
ERZE07A331 9.0 6.0 7.5 12.5 2.8
ERZE07A361 9.0 6.2 7.5 12.5 2.9
A

ERZE07A391 9.0 6.3 7.5 12.5 3.0


ERZE07A431 9.0 6.5 7.5 12.5 3.1 L

ERZE07A471 9.0 6.8 7.5 12.5 3.3


20.0 min.

ERZE07A511 9.0 7.0 7.5 12.5 3.5 F

ERZE07A561 9.0 7.4 7.5 13.5 3.8 ø0.8 F


ERZE07A621 10.0 7.8 7.5 13.5 4.0

Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
13
D type / E7 series
Typical characteristics
Voltage vs. Current Impulse Derating (Relation between
impulse width and impulse current multiple)

ERZE07A201 to ERZE07A621 ERZE07A201 to ERZE07A621

10000
Max.Leakage
Current Max.Clamping Voltage 2 times:5 min. interval
2000 621 up to 10 times:2 min. interval
561 up to 106 times : 10 sec. interval
511
471
431
561 391
511 361
331
1000 471
431
900 391
271 1000
361 241
800 221
700 201

600
500

Impulse Current(A)
400
Voltage(V)

300 100

200

100
10
90 331
80 221
70
60
50 Test current waveform
10–6 to 10–3 A: Direct current
40 10–1 to 104 A: 8/20 μs

30 1
10-6 10-5 10-4 10-3 10-2 10-1 100 101 102 103 104 105
20 100 1000 10000

Current(A) Impulse Width(μs)

Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
14
D type / E8 series
Ratings and characteristics
●Operating temperature range : ‒40 to 85 ℃ ●Storage temperature range : ‒40 to 125 ℃
Maximum
Varistor Clamping Maximum energy peak current Capacitance
Maximum Rated
voltage voltage (8/20 μs) (max.)
allowable voltage power
Part No. at 1 mA (max.)**lp at 1 kHz
(10/1000 μs) (2 ms) 1 time 2 times
ACrms DC
(V) (V) (W) (J) (J) (A) (A) (pF)
(V) (V)

ERZE08A201 200(185 to 225) 130 170 340 0.4 35 25 3500 2500 390
ERZE08A221 220(198 to 242) 140 180 360 0.4 39 27.5 3500 2500 380
ERZE08A241 240(216 to 264) 150 200 395 0.4 42 30 3500 2500 360
ERZE08A271 270(247 to 303) 175 225 455 0.4 49 35 3500 2500 330
ERZE08A331 330(297 to 363) 210 270 545 0.4 58 42 3500 2500 300
ERZE08A361 360(324 to 396) 230 300 595 0.4 65 45 3500 2500 280
ERZE08A391 390(351 to 429) 250 320 650 0.4 70 50 3500 2500 260
ERZE08A431 430(387 to 473) 275 350 710 0.4 80 55 3500 2500 230
ERZE08A471 470(423 to 517) 300 385 775 0.4 85 60 3500 2500 180
ERZE08A511 510(459 to 561) 320 410 845 0.4 92 67 3500 2500 150
ERZE08A561 560(504 to 616) 350 450 930 0.4 92 67 3500 2500 150
ERZE08A621 620(558 to 682) 385 505 1025 0.4 92 67 3500 2500 140
ERZE08A681 680(612 to 748) 420 560 1120 0.4 92 67 3500 2500 130
ERZE08A751 750(675 to 825) 460 615 1240 0.4 100 70 3500 2500 130
✽Ip Measuring current of clamping voltage : 25 A

Dimensions in mm (not to scale)


Unit : mm

Part No. D max. T max. F±1.0 A max. L±1.0


ERZE08A201 10.5 5.1 7.5 13.5 1.9
ERZE08A221 10.5 5.2 7.5 13.5 2.0
ERZE08A241 10.5 5.3 7.5 13.5 2.1
ERZE08A271 10.5 5.5 7.5 13.5 2.3
ERZE08A331 10.5 5.9 7.5 13.5 2.6
ERZE08A361 10.5 6.1 7.5 13.5 2.8 D
T
ERZE08A391 10.5 6.3 7.5 13.5 2.9
ERZE08A431 10.5 6.5 7.5 13.5 3.1
A

ERZE08A471 10.5 7.3 7.5 13.5 3.6


ERZE08A511 10.5 7.8 7.5 13.5 4.0
L
ERZE08A561 10.5 8.1 7.5 13.5 4.3
20.0 min.

ERZE08A621 11.5 8.7 7.5 14.5 4.7 F


ERZE08A681 11.5 9.0 7.5 14.5 5.0
ø0.8 F
ERZE08A751 11.5 9.7 7.5 14.5 5.6

Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
15
D type / E8 series
Typical characteristics
Voltage vs. Current Impulse Derating (Relation between
impulse width and impulse current multiple)

ERZE08A201 to ERZE08A511 ERZE08A201 to ERZE08A511


10000
Max.Leakage 2 times:5 min. interval
2000 Current Max.Clamping Voltage
up to 10 times:2 min. interval
up to 106 times : 10 sec. interval

511
471
431
391
1000 471 361
431 331
900 271 1000
800 391
241
361
700 221
201
600
500

Impulse Current(A)
Voltage(V)

400

300 100

200

100
10
90 331
80
221
70
60
50 Test current waveform
10–6 to 10–3 A: Direct current
10–1 to 104 A: 8/20 μs
40
30 1
10-6 10-5 10-4 10-3 10-2 10-1 100 101 102 103 104 105 20 100 1000 10000

Current(A) Impulse Width(μs)

ERZE08A561 to ERZE08A751 ERZE08A561 to ERZE08A751


5000 10000
Max.Leakage Max.Clamping Voltage
Current
4000 2 times:5 min. interval
up to 10 times:2 min. interval
up to 106 times : 10 sec. interval
3000

1000
2000
751
681
621
Impulse Current(A)

561
Voltage(V)

1000
100
900
800
700
600

500
10
400

300 751
681 Test current waveform
10–6 to 10–3 A: Direct current
621 10–1 to 104 A: 8/20 μs

200 1
10-6 10-5 10-4 10-3 10-2 10-1 100 101 102 103 104 105 20 100 1000 10000

Current(A) Impulse Width(μs)

Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
16
D type / E10 series
Ratings and characteristics
●Operating temperature range : ‒40 to 85 ℃ ●Storage temperature range : ‒40 to 125 ℃

Maximum
Varistor Clamping Maximum energy peak current Capacitance
Maximum Rated
voltage voltage (8/20 μs) (max.)
allowable voltage power
Part No. at 1 mA (max.)**lp at 1 kHz
(10/1000 μs) (2 ms) 1 time 2 times
ACrms DC
(V) (V) (W) (J) (J) (A) (A) (pF)
(V) (V)

ERZE10A201 200(185 to 225) 130 170 340 0.5 47 34 4500 3000 630
ERZE10A221 220(198 to 242) 140 180 360 0.5 50 36 4500 3000 600
ERZE10A241 240(216 to 264) 150 200 395 0.5 56 40 4500 3000 570
ERZE10A271 270(247 to 303) 175 225 455 0.5 64 46 4500 3000 530
ERZE10A331 330(297 to 363) 210 270 545 0.5 72 52 4500 3000 470
ERZE10A361 360(324 to 396) 230 300 595 0.5 84 60 4500 3000 430
ERZE10A391 390(351 to 429) 250 320 650 0.5 91 65 4500 3000 400
ERZE10A431 430(387 to 473) 275 350 710 0.5 99 71 4500 3000 350
ERZE10A471 470(423 to 517) 300 385 775 0.5 106 76 4500 3000 320
ERZE10A511 510(459 to 561) 320 410 845 0.5 117 84 4500 3000 300
ERZE10A561 560(504 to 616) 350 450 930 0.5 120 86 4500 3000 290
ERZE10A621 620(558 to 682) 385 505 1025 0.5 126 88 4500 3000 280
ERZE10A681 680(612 to 748) 420 560 1120 0.5 133 95 4500 3000 260
ERZE10A751 750(675 to 825) 460 615 1240 0.5 140 100 4500 3000 250
ERZE10A821 820(738 to 902) 510 670 1355 0.5 154 110 4500 3000 230
ERZE10A911 910(819 to 1001) 550 745 1500 0.5 168 112 4500 3000 220
ERZE10A102 1000(900 to 1100) 625 825 1650 0.5 182 130 4500 3000 200
ERZE10A112 1100(990 to 1210) 680 895 1815 0.5 196 140 4500 3000 180
✽Ip Measuring current of clamping voltage : 50 A

Dimensions in mm (not to scale)


Unit : mm

Part No. D max. T max. F±1.0 A max. L±1.0


ERZE10A201 11.5 5.3 7.5 15.0 2.1
ERZE10A221 11.5 5.4 7.5 15.0 2.3
ERZE10A241 11.5 5.5 7.5 15.0 2.4
ERZE10A271 11.5 5.7 7.5 15.0 2.5
ERZE10A331 11.5 6.0 7.5 15.0 2.8
ERZE10A361 11.5 6.2 7.5 15.0 2.9
ERZE10A391 11.5 6.3 7.5 15.0 3.0
ERZE10A431 11.5 6.5 7.5 15.0 3.1
ERZE10A471 11.5 6.8 7.5 15.0 3.3
ERZE10A511 11.5 7.0 7.5 15.0 3.5 D
T
ERZE10A561 11.5 7.4 7.5 15.0 3.8
ERZE10A621 12.5 7.8 7.5 16.0 4.0
A

ERZE10A681 12.5 8.1 7.5 16.0 4.2


ERZE10A751 12.5 8.6 7.5 16.0 4.6 L
ERZE10A821 12.5 8.9 7.5 16.0 5.0
20.0 min.

ERZE10A911 12.5 9.5 7.5 16.0 5.7 F


ERZE10A102 12.5 10.0 7.5 16.0 6.2
ø0.8 F
ERZE10A112 12.5 10.6 7.5 16.0 6.8

Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
17
D type / E10 series
Typical characteristics
Voltage vs. Current Impulse Derating (Relation between
impulse width and impulse current multiple)

ERZE10A201 to ERZE10A561 ERZE10A201 to ERZE10A561


10000
Max.Leakage 2 times:5 min. interval
Max.Clamping Voltage
Current up to 10 times:2 min. interval
2000 561 up to 106 times : 10 sec. intervalA
511
471
511 431
471 391
361
431 331
1000 391
900 361 271 1000
800 241
221
700 201
600

500

Impulse Current(A)
400
Voltage (V)

300 100

200

100
331 10
90
221
80
70
60 Test current waveform
50 10–6 to 10–3 A: Direct current
10–1 to 104 A: 8/20 μs
40

30 1
10-6 10-5 10-4 10-3 10-2 10-1 100 101 102 103 104 105 20 100 1000 10000

Current(A) Impulse Width(μs)

ERZE10A621 to ERZE10A112 ERZE10A621 to ERZE10A112


5000 10000
Max.Leakage Max.Clamping Voltage 2 times:5 min. interval
Current
4000 up to 10 times:2 min. interval
112 up to 106 times : 10 sec. interval
102
911
3000
821
751
681
1000
621
2000
Impulse Current(A)

102
911
Voltage(V)

821
1000 100
900
800

700

600

500

10
400

300 Test current waveform


751 10–6 to 10–3 A: Direct current
681 10–1 to 104 A: 8/20 μs
621

200 1
10-6 10-5 10-4 10-3 10-2 10-1 100 101 102 103 104 105 20 100 1000 10000

Current(A) Impulse Width(μs)

Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
18
D type / E11 series
Ratings and characteristics
●Operating temperature range : ‒40 to 85 ℃ ●Storage temperature range : ‒40 to 125 ℃
Maximum
Varistor Clamping Maximum energy peak current Capacitance
Maximum Rated
voltage voltage (8/20 μs) (max.)
allowable voltage power
Part No. at 1 mA (max.)**lp at 1 kHz
(10/1000 μs) (2 ms) 1 time 2 times
ACrms DC
(V) (V) (W) (J) (J) (A) (A) (pF)
(V) (V)

ERZE11A201 200(185 to 225) 130 170 340 0.6 70 50 6000 5000 690
ERZE11A221 220(198 to 242) 140 180 360 0.6 78 55 6000 5000 660
ERZE11A241 240(216 to 264) 150 200 395 0.6 84 60 6000 5000 620
ERZE11A271 270(247 to 303) 175 225 455 0.6 99 70 6000 5000 580
ERZE11A331 330(297 to 363) 210 270 545 0.6 115 80 6000 4500 520
ERZE11A361 360(324 to 396) 230 300 595 0.6 130 90 6000 4500 480
ERZE11A391 390(351 to 429) 250 320 650 0.6 140 100 6000 4500 450
ERZE11A431 430(387 to 473) 275 350 710 0.6 155 110 6000 4500 400
ERZE11A471 470(423 to 517) 300 385 775 0.6 175 125 6000 4500 360
ERZE11A511 510(459 to 561) 320 410 845 0.6 190 136 6000 4500 310
ERZE11A561 560(504 to 616) 350 450 930 0.6 190 136 6000 4500 310
ERZE11A621 620(558 to 682) 385 505 1025 0.6 190 136 5000 4500 300
ERZE11A681 680(612 to 748) 420 560 1120 0.6 190 136 5000 4500 290
ERZE11A751 750(675 to 825) 460 615 1240 0.6 210 150 5000 4500 280
ERZE11A821 820(738 to 902) 510 670 1355 0.6 235 165 5000 4500 260
ERZE11A911 910(819 to 1001) 550 745 1500 0.6 255 180 5000 4500 240
ERZE11A102 1000(900 to 1100) 625 825 1650 0.6 280 200 5000 4500 220
ERZE11A112 1100(990 to 1210) 680 895 1815 0.6 310 220 5000 4500 200
✽Ip Measuring current of clamping voltage : 50 A

Dimensions in mm (not to scale)


Unit : mm

Part No. D max. T max. F±1.0 A max. L±1.0


ERZE11A201 13.0 5.2 7.5 17.0 1.9
ERZE11A221 13.0 5.3 7.5 17.0 2.0
ERZE11A241 13.0 5.4 7.5 17.0 2.1
ERZE11A271 13.0 5.6 7.5 17.0 2.3
ERZE11A331 13.0 5.9 7.5 17.0 2.6
ERZE11A361 13.0 6.1 7.5 17.0 2.8
ERZE11A391 13.0 6.2 7.5 17.0 2.9
ERZE11A431 13.0 6.4 7.5 17.0 3.1
ERZE11A471 13.0 6.6 7.5 17.0 3.3 D
T
ERZE11A511 13.0 6.8 7.5 17.0 3.5
ERZE11A561 13.0 7.2 7.5 17.0 3.8
A

ERZE11A621 14.0 7.5 7.5 18.0 4.2


ERZE11A681 14.0 7.8 7.5 18.0 4.5 L
ERZE11A751 14.0 8.2 7.5 18.0 4.9
20.0 min.

ERZE11A821 14.0 8.5 7.5 18.0 5.2 F


ERZE11A911 14.0 9.0 7.5 18.0 5.7
ø0.8 F
ERZE11A102 14.0 9.5 7.5 18.0 6.2
ERZE11A112 14.0 10.1 7.5 18.0 6.8

Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
19
D type / E11 series
Typical characteristics
Voltage vs. Current Impulse Derating (Relation between
impulse width and impulse current multiple)

ERZE11A201 to ERZE11A511 ERZE11A201 to ERZE11A511


10000
Max.Leakage Max.Clamping Voltage 2 times:5 min. interval
Current up to 10 times:2 min. interval
2000 up to 106 times : 10 sec. interval
511
471
431
391
471
361
1000 431 331
391 271
900 241 1000
361
800 221
201
700
600

Impulse Current(A)
500
400
Voltage(V)

300 100

200

100
90 331 10
80 221
70
60
Test current waveform
50 10–6 to 10–3 A: Direct current
10–1 to 104 A: 8/20 μs
40
30
10-6 10-5 10-4 10-3 10-2 10-1 100 101 102 103 104 105 120 100 1000 10000
Current(A) Impulse Width(μs)

ERZE11A561 to ERZE11A112 ERZE11A561 to ERZE11A112


5000 10000
Max.Leakage Max.Clamping Voltage 2 times:5 min. interval
Current
up to 10 times:2 min. interval
4000 up to 106 times : 10 sec. interval

3000 112
102

911
821 1000
2000 751
681

102 621
561
Impulse Current(A)

911
821
Voltage(V)

1000 100
900
800
700

600

500
10
400

300 Test current waveform


10–6 to 10–3 A: Direct current
751 10–1 to 104 A: 8/20 μs
681
621
200 1
10-6 10-5 10-4 10-3 10-2 10-1 100 101 102 103 104 105 20 100 1000 10000

Current(A) Impulse Width(μs)

Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
20
D type / E14 series
Ratings and characteristics
●Operating temperature range : ‒40 to 85 ℃ ●Storage temperature range : ‒40 to 125 ℃

Maximum
Varistor Clamping Maximum energy peak current Capacitance
Maximum Rated
voltage voltage (8/20 μs) (max.)
allowable voltage power
Part No. at 1 mA (max.)**lp at 1 kHz
(10/1000 μs) (2 ms) 1 time 2 times
ACrms DC
(V) (V) (W) (J) (J) (A) (A) (pF)
(V) (V)

ERZE14A201 200(185 to 225) 130 170 340 1.0 140 100 10000 7000 1300
ERZE14A221 220(198 to 242) 140 180 360 1.0 155 110 10000 7000 1200
ERZE14A241 240(216 to 264) 150 200 395 1.0 168 120 10000 7000 1100
ERZE14A271 270(247 to 303) 175 225 455 1.0 190 135 10000 7000 1000
ERZE14A331 330(297 to 363) 210 270 545 1.0 228 160 10000 6500 900
ERZE14A361 360(324 to 396) 230 300 595 1.0 255 180 10000 6500 900
ERZE14A391 390(351 to 429) 250 320 650 1.0 275 195 10000 6500 800
ERZE14A431 430(387 to 473) 275 350 710 1.0 303 215 10000 6500 800
ERZE14A471 470(423 to 517) 300 385 775 1.0 350 250 10000 6500 750
ERZE14A511 510(459 to 561) 320 410 845 1.0 382 273 10000 6500 700
ERZE14A561 560(504 to 616) 350 450 930 1.0 382 273 10000 6500 700
ERZE14A621 620(558 to 682) 385 505 1025 1.0 382 273 7500 6500 650
ERZE14A681 680(612 to 748) 420 560 1120 1.0 382 273 7500 6500 600
ERZE14A751 750(675 to 825) 460 615 1240 1.0 420 300 7500 6500 530
ERZE14A821 820(738 to 902) 510 670 1355 1.0 460 325 7500 6500 500
ERZE14A911 910(819 to 1001) 550 745 1500 1.0 510 360 7500 6500 400
ERZE14A102 1000(900 to 1100) 625 825 1650 1.0 565 400 7500 6500 400
ERZE14A112 1100(990 to 1210) 680 895 1815 1.0 620 440 7500 6500 350
✽Ip Measuring current of clamping voltage : 100 A

Dimensions in mm (not to scale)


Unit : mm

Part No. D max. T max. F±1.0 A max. L±1.0


ERZE14A201 16.5 5.2 10.0 20.0 2.1
ERZE14A221 16.5 5.3 10.0 20.0 2.2
ERZE14A241 16.5 5.4 10.0 20.0 2.3
ERZE14A271 16.5 5.6 10.0 20.0 2.5
ERZE14A331 16.5 5.9 10.0 20.0 2.8
ERZE14A361 16.5 6.1 10.0 20.0 3.0
ERZE14A391 16.5 6.2 10.0 20.0 3.1
ERZE14A431 16.5 6.4 10.0 20.0 3.3
ERZE14A471 16.5 6.6 10.0 20.0 3.5
D
ERZE14A511 16.5 6.8 10.0 20.0 3.7 T
ERZE14A561 16.5 7.2 10.0 20.0 4.0
ERZE14A621 17.5 7.5 10.0 20.5 4.4
A

ERZE14A681 17.5 7.8 10.0 20.5 4.7


ERZE14A751 17.5 8.2 10.0 20.5 5.1 L
ERZE14A821 17.5 8.5 10.0 20.5 5.4
20.0 min.

ERZE14A911 17.5 9.0 10.0 20.5 5.9 F

ERZE14A102 17.5 9.5 10.0 20.5 6.4 ø1.0 F


ERZE14A112 17.5 10.1 10.0 20.5 7.2

Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
21
D type / E14 series
Typical characteristics
Voltage vs. Current Impulse Derating (Relation between
impulse width and impulse current multiple)

ERZE14A201 to ERZE14A511 ERZE14A201 to ERZE14A511


10000
Max.Leakage 2 times:5 min. interval
Max.Clamping Voltage
Current up to 10 times:2 min. interval
2000 up to 106 times : 10 sec. interval
511
471 471
431
431 391
391 361
1000 361 331
900 271 1000
800 241
700 221
201
600

Impulse Current (A)


500
Voltage(V)

400

300 100

200

100 10
90
80 241
70 331
60 221

50 Test current waveform


10–6 to 10–3 A: Direct current
10–1 to 104 A: 8/20 μs
40

30 1
10-6 10-5 10-4 10-3 10-2 10-1 100 101 102 103 104 105 20 100 1000 10000

Current(A) Impulse Width(μs)

ERZE14A561 to ERZE14A112 ERZE14A561 to ERZE14A112


5000 10000
Max.Leakage Max.Clamping Voltage 2 times:5 min. interval
Current up to 10 times:2 min. interval
4000 up to 106 times : 10 sec. interval

3000 112

102
911
821 1000
2000 751
681
621
561
Impulse Current(A)

102
Voltage(V)

911
821
1000 100
900
800

700

600
500
10
400

300 Test current waveform


751 10–6 to 10–3 A: Direct current
681 10–1 to 104 A: 8/20 μs
621
1
200
10-6 10-5 10-4 10-3 10-2 10-1 100 101 102 103 104 105 20 100 1000 10000

Current(A) Impulse Width(μs)

Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
22
D type / E series (Leads cut type)
Straight leads cut type (Bulk type)
※ Ratings and characteristics is refer to bulk standard type.

Dimensions in mm (not to scale)


D T**

ød
B

W L*

notes ✽ Dimension “L”: Conforms to each individtual specification.


✽✽ Dimension “T”: Conforms to each individual specification.
Unit : mm

Series E5 E7 E8 E10 E11


Varister Voltage
Symbol
201 to 471 201 to 511 561 621 201 to 561 621 to 751 201 to 561 621 to 112 201 to 561 621 to 112

D 7.0 max. 9.0 max. 9.0 max. 10.0 max. 10.5 max. 11.5 max. 11.5 max. 12.5 max. 13.0 max. 14.0 max.

H 10.0 max. 12.5 max. 13.5 max. 13.5 max. 13.5 max. 14.5 max. 15.0 max. 16.0 max. 17.0 max. 18.0 max.

W 5.0±1.0 7.5±1.0 7.5±1.0 7.5±1.0 7.5±1.0 7.5±1.0 7.5±1.0 7.5±1.0 7.5±1.0 7.5±1.0
+0.06 +0.08 +0.08 +0.08 +0.08 +0.08 +0.08 +0.08 +0.08 +0.08
ød 0.60
-0.05
0.80
-0.05
0.80
-0.05
0.80
-0.05
0.80
-0.05
0.80
-0.05
0.80
-0.05
0.80
-0.05
0.80
-0.05
0.80
-0.05
B 4.0±1.0 4.0±1.0 4.0±1.0 4.0±1.0 4.0±1.0 4.0±1.0 4.0±1.0 4.0±1.0 4.0±1.0 4.0±1.0
Standard
products part No.
ERZE05A□□□CS ERZE07A□□□CS ERZE08A□□□CS ERZE10A□□□CS ERZE11A□□□CS

Crimped leads cut type (Bulk Type)


※ Ratings and characteristics is refer to bulk standard type.

Dimensions in mm (not to scale)


D T**
A

***
C
C
ød
B

W L*

notes ✽ Dimension “L”: Conforms to each individtual specification.


✽✽ Dimension “T”: Conforms to each individual specification.
✽✽✽ Resin extenyions : No resin below the center of the hook.
Unit : mm

Series E5 E7 E8 E10 E11


Varister Voltage
Symbol
201 to 471 201 to 511 561 621 201 to 561 621 to 751 201 to 561 621 to 681 751 to 112 201 to 561 621 to 112
D 7.0 max. 9.0 max. 9.0 max. 10.0 max. 10.5 max. 11.5 max. 11.5 max. 12.5 max. 12.5 max. 13.0 max. 14.0 max.
A 13.0 max. 15.5 max. 16.5 max. 16.5 max. 17.0 max. 18.0 max. 18.0 max. 19.5 max.. 20.5 max. 20.5 max. 21.5 max.
C 1.2±1.4 1.4±1.4 1.4±1.4 1.4±1.4 1.4±1.4 1.4±1.4 1.4±1.4 1.4±1.4 1.4±1.4 1.4±1.4 1.4±1.4
W 5.0±1.0 7.5±1.0 7.5±1.0 7.5±1.0 7.5±1.0 7.5±1.0 7.5±1.0 7.5±1.0 7.5±1.0 7.5±1.0 7.5±1.0
+0.06 +0.08 +0.08 +0.08 +0.08 +0.08 +0.08 +0.08 +0.08 +0.08 +0.08
ød 0.60
-0.05
0.80
-0.05
0.80
-0.05
0.80
-0.05
0.80
-0.05
0.80
-0.05
0.80
-0.05
0.80
-0.05
0.80
-0.05
0.80
-0.05
0.80
-0.05
B 4.0±1.0 4.0±1.0 4.0±1.0 4.0±1.0 4.0±1.0 4.0±1.0 4.0±1.0 4.0±1.0 4.0±1.0 4.0±1.0 4.0±1.0
Standard
products part No.
ERZE05B□□□CS ERZE07B□□□CS ERZE08B□□□CS ERZE10B□□□CS ERZE11B□□□CS

Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
23
D type / E series (Taping specifications)
Taping specifications for automated assembly (Straight leads and taping)
※ Ratings and characteristics is refer to bulk standard type.
Dimensions in mm (not to scale)

P2 P øD △h
T*
A

P1

W2

H0
F1

H
W0

W1
L

Position of

W
F
H0 dimension

P0 ød øD0 Position of
F1 dimension

t
✽ Dimension “T”: Conforms to each individual specification.

Unit : mm

Series E5 E7 E8 E10 E11


Varister
Symbol Voltage
201 to 471 201 to 271 331 to 551 561 621 201 to 221 241 to 561 621 to 751 201 to 221 241 to 561 621 to 112 201 to 221 241 to 561 621 to 112

P 12.7±1.0 15.0±1.0 15.0±1.0 15.0±1.0 15.0±1.0 15.0±1.0 15.0±1.0 15.0±1.0 15.0±1.0 15.0±1.0 15.0±1.0 15.0±1.0 15.0±1.0 15.0±1.0

P0 12.7±0.3 15.0±0.3 15.0±0.3 15.0±0.3 15.0±0.3 15.0±0.3 15.0±0.3 15.0±0.3 15.0±0.3 15.0±0.3 15.0±0.3 15.0±0.3 15.0±0.3 15.0±0.3

P1 3.85±0.70 3.75±0.70 3.75±0.70 3.75±0.70 3.75±0.70 3.75±0.70 3.75±0.70 3.75±0.70 3.75±0.70 3.75±0.70 3.75±0.70 3.75±0.70 3.75±0.70 3.75±0.70

P2 6.36±1.30 7.5±1.3 7.5±1.3 7.5±1.3 7.5±1.3 7.5±1.3 7.5±1.3 7.5±1.3 7.5±1.3 7.5±1.3 7.5±1.3 7.5±1.3 7.5±1.3 7.5±1.3
+0.06 +0.08 +0.08 +0.08 +0.08 +0.08 +0.08 +0.08 +0.08 +0.08 +0.08 +0.08 +0.08 +0.08
ød 0.60
-0.05
0.80
-0.05
0.80
-0.05
0.80
-0.05
0.80
-0.05
0.80
-0.05
0.80
-0.05
0.80
-0.05
0.80
-0.05
0.80
-0.05
0.80
-0.05
0.80
-0.05
0.80
-0.05
0.80
-0.05

F 5.0±0.5 7.5±0.5 7.5±0.5 7.5±0.5 7.5±0.5 7.5±0.5 7.5±0.5 7.5±0.5 7.5±0.5 7.5±0.5 7.5±0.5 7.5±0.5 7.5±0.5 7.5±0.5

△h 0±2 0±2 0±2 0±2 0±2 0±2 0±2 0±2 0±2 0±2 0±2 0±2 0±2 0±2
+1.0 +1.0 +1.0 +1.0 +1.0 +1.0 +1.0 +1.0 +1.0 +1.0 +1.0 +1.0 +1.0 +1.0
W 18.0
-0.5
18.0
-0.5
18.0
-0.5
18.0
-0.5
18.0
-0.5
18.0
-0.5
18.0
-0.5
18.0
-0.5
18.0
-0.5
18.0
-0.5
18.0
-0.5
18.0
-0.5
18.0
-0.5
18.0
-0.5

W0 5.0 min. 5.0 min. 5.0 min. 5.0 min. 5.0 min. 5.0 min. 5.0 min. 5.0 min. 5.0 min. 5.0 min. 5.0 min. 5.0 min. 5.0 min. 5.0 min.

W1 9.0±0.5 9.0±0.5 9.0±0.5 9.0±0.5 9.0±0.5 9.0±0.5 9.0±0.5 9.0±0.5 9.0±0.5 9.0±0.5 9.0±0.5 9.0±0.5 9.0±0.5 9.0±0.5

W2 3.0 max. 3.0 max. 3.0 max. 3.0 max. 3.0 max. 3.0 max. 3.0 max. 3.0 max. 3.0 max. 3.0 max. 3.0 max. 3.0 max. 3.0 max. 3.0 max.

H Approx. 22 Approx. 22 Approx. 22 Approx. 22 Approx. 22 Approx. 22 Approx. 22 Approx. 22 Approx. 22 Approx. 22 Approx. 22 Approx. 22 Approx. 22 Approx. 22
+2.0 +2.0 +2.0 +2.0
H0 17.0±0.5 18.0
0
―― ―― ―― 18.0
0
―― ―― 18.0
0
―― ―― 18.0
0
―― ――

+0.75 +0.75 +0.75 +0.75 +0.75 +0.75 +0.75 +0.75 +0.75


F1 ―― ―― 16.0 16.0 16.0 ―― 16.0 16.0 ―― 16.0 16.0 ―― 16.0 16.0
-0.50 -0.50 -0.50 -0.50 -0.50 -0.50 -0.50 -0.50 -0.50

ø D0 ø4.0±0.2 ø4.0±0.2 ø4.0±0.2 ø4.0±0.2 ø4.0±0.2 ø4.0±0.2 ø4.0±0.2 ø4.0±0.2 ø4.0±0.2 ø4.0±0.2 ø4.0±0.2 ø4.0±0.2 ø4.0±0.2 ø4.0±0.2

t 0.6±0.3 0.6±0.3 0.6±0.3 0.6±0.3 0.6±0.3 0.6±0.3 0.6±0.3 0.6±0.3 0.6±0.3 0.6±0.3 0.6±0.3 0.6±0.3 0.6±0.3 0.6±0.3

L 11.0 max. 11.0 max. 11.0 max. 11.0 max. 11.0 max. 11.0 max. 11.0 max. 11.0 max. 11.0 max. 11.0 max. 11.0 max. 11.0 max. 11.0 max. 11.0 max.

øD 7.0 max. 9.0 max. 9.0 max. 9.0 max. 10.0 max. 10.5 max. 10.5 max. 11.5 max. 11.5 max. 11.5 max. 12.5 max. 13.0 max. 13.0 max. 14.0 max.

A 10.0 max. 12.5 max. 12.5 max. 13.5 max. 13.5 max. 13.5 max. 13.5 max. 14.5 max. 15.0 max. 15.0 max. 16.0 max. 17.0 max. 17.0 max. 18.0 max.
Standard
products part
ERZE05E □□ ERZE07E□□□ ERZE08E□□□ ERZE10E□□□ ERZE11E□□□

Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
24
D type / E series (Taping specifications)
Taping specifications for automated assembly (Crimped leads and taping)
※ Ratings and characteristics is refer to bulk standard type.
Dimensions in mm (not to scale)

P2 P øD △h
T*

A
P1

W2

H0
H
W0

W1
L

W
F

P0 ød øD0

t
✽ Dimension “T”: Conforms to each individual specification.

Unit : mm

Series E5 E7 E8 E10 E11


Varister
Symbol Voltage
201 to 471 201 to 551 561 621 201 to 221 241 to 561 621 to 751 201 to 561 621 to 681 751 to 112 201 to 221 241 to 561 621 to 112
P 12.7±1.0 15.0±1.0 15.0±1.0 15.0±1.0 15.0±1.0 15.0±1.0 15.0±1.0 15.0±1.0 15.0±1.0 15.0±1.0 15.0±1.0 15.0±1.0 15.0±1.0

P0 12.7±0.3 15.0±0.3 15.0±0.3 15.0±0.3 15.0±0.3 15.0±0.3 15.0±0.3 15.0±0.3 15.0±0.3 15.0±0.3 15.0±0.3 15.0±0.3 15.0±0.3

P1 3.85±0.70 3.75±0.70 3.75±0.70 3.75±0.70 3.75±0.70 3.75±0.70 3.75±0.70 3.75±0.70 3.75±0.70 3.75±0.70 3.75±0.70 3.75±0.70 3.75±0.70

P2 6.36±1.30 7.5±1.3 7.5±1.3 7.5±1.3 7.5±1.3 7.5±1.3 7.5±1.3 7.5±1.3 7.5±1.3 7.5±1.3 7.5±1.3 7.5±1.3 7.5±1.3
+0.06 +0.08 +0.08 +0.08 +0.08 +0.08 +0.08 +0.08 +0.08 +0.08 +0.08 +0.08 +0.08
ød 0.60
-0.05
0.80
-0.05
0.80
-0.05
0.80
-0.05
0.80
-0.05
0.80
-0.05
0.80
-0.05
0.80
-0.05
0.80
-0.05
0.80
-0.05
0.80
-0.05
0.80
-0.05
0.80
-0.05

F 5.0±0.5 7.5±0.5 7.5±0.5 7.5±0.5 7.5±0.5 7.5±0.5 7.5±0.5 7.5±0.5 7.5±0.5 7.5±0.5 7.5±0.5 7.5±0.5 7.5±0.5

△h 0±2 0±2 0±2 0±2 0±2 0±2 0±2 0±2 0±2 0±2 0±2 0±2 0±2
+1.0 +1.0 +1.0 +1.0 +1.0 +1.0 +1.0 +1.0 +1.0 +1.0 +1.0 +1.0 +1.0
W 18.0
-0.5
18.0
-0.5
18.0
-0.5
18.0
-0.5
18.0
-0.5
18.0
-0.5
18.0
-0.5
18.0
-0.5
18.0
-0.5
18.0
-0.5
18.0
-0.5
18.0
-0.5
18.0
-0.5

W0 5.0 min. 5.0 min. 5.0 min. 5.0 min. 5.0 min. 5.0 min. 5.0 min. 5.0 min. 5.0 min. 5.0 min. 5.0 min. 5.0 min. 5.0 min.

W1 9.0±0.5 9.0±0.5 9.0±0.5 9.0±0.5 9.0±0.5 9.0±0.5 9.0±0.5 9.0±0.5 9.0±0.5 9.0±0.5 9.0±0.5 9.0±0.5 9.0±0.5

W2 3.0 max. 3.0 max. 3.0 max. 3.0 max. 3.0 max. 3.0 max. 3.0 max. 3.0 max. 3.0 max. 3.0 max. 3.0 max. 3.0 max. 3.0 max.

H Approx. 22 Approx. 22 Approx. 22 Approx. 22 Approx. 22 Approx. 22 Approx. 22 Approx. 22 Approx. 22 Approx. 22 Approx. 22 Approx. 22 Approx. 22

H0 17.0±0.5 16.0±0.5 16.0±0.5 16.0±0.5 16.0±0.5 16.0±0.5 16.0±0.5 16.0±0.5 16.0±0.5 16.0±0.5 16.0±0.5 16.0±0.5 16.0±0.5

ø D0 ø4.0±0.2 ø4.0±0.2 ø4.0±0.2 ø4.0±0.2 ø4.0±0.2 ø4.0±0.2 ø4.0±0.2 ø4.0±0.2 ø4.0±0.2 ø4.0±0.2 ø4.0±0.2 ø4.0±0.2 ø4.0±0.2

t 0.6±0.3 0.6±0.3 0.6±0.3 0.6±0.3 0.6±0.3 0.6±0.3 0.6±0.3 0.6±0.3 0.6±0.3 0.6±0.3 0.6±0.3 0.6±0.3 0.6±0.3

L 11.0 max. 11.0 max. 11.0 max. 11.0 max. 11.0 max. 11.0 max. 11.0 max. 11.0 max. 11.0 max. 11.0 max. 11.0 max. 11.0 max. 11.0 max.

øD 7.0 max. 9.0 max. 9.0 max. 10.0 max. 10.5 max. 10.5 max. 11.5 max. 11.5 max. 12.5 max. 12.5 max. 13.0 max. 13.0 max. 14.0 max.

A 13.0 max. 15.5 max. 16.5 max. 16.5 max. 17.0 max. 17.0 max. 18.0 max. 18.0 max. 19.5 max. 20.5 max. 20.5 max. 20.5 max. 21.5 max.
Standard
products part
ERZE05F□□□ ERZE07F□□□ ERZE08F□□□ ERZE10F□□□ ERZE11F□□□

Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
25
D type / E series
Application note for safety standards
● Approvals products lists in "Reference Guide to Standard Products."
● UL and VDE : Registered in "Type name", it isn’t registered in "Panasonic Part No."
● CQC : Registered in "Panasonic Part No."
● "Rated Voltages" are specified for UL recognized components in list shown below.

The AC rated voltage and maximum allowable voltage


Maximum allowable voltage Rated voltage (Vrms)
Type name
ACrms (V) DC (V) UL1449
E✽201 130 170 118
E✽221 140 180 127
E✽241 150 200 136
E✽271 175 225 159
E✽331 210 270 189
E✽361 230 300 209
E✽391 250 320 227
E✽431 275 350 250
E✽471 300 385 272
E✽511 320 410 291
E✽561 350 450 320
E✽621 385 505 350
E✽681 420 560 381
E✽751 460 615 418
E✽821 510 670 463
E✽911 550 745 500
E✽102 625 825 568
E✽112 680 895 600

✽:5 Series is blank, 7 series is 7, 8 series is 8, 10 series is 10, 11 series is 11, 14 series is 14

Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
26
D type / E series
Explanation of the contents
Mark Explanation of the content

Abbreviation of
□□□
E✽□□□ part No.
(Type Name) Nominal varistor volage

Marking Factory None : Japan



identication mark Q : Indonesia

2019 : 9, 2020 : K, 2021 : A


◆*1 Year code
2022 : B, 2023 : C, 2024 : D

Jan : 1 to Sep : 9,
◇ Monthly code
Oct. : 0, Nov. : N,Dec. : D

UL Recognized components mark

✽: 5 series is blank, 7 series is 7, 8 series is 8, 10 series is 10, 11 series is 11,


14 series is 14
*1: If the 10's digit of a Christian year is an even year, as an end abbreviation, an
alphabetic character is used.
1 : A, 2 : B, 3 : C, 4 : D, 5 : E, 6 : F, 7 : G, 8 : H, 9 : J, 0 : K
If the 10's digit of a Christian year is an odd year, as an end abbreviation, a
number is used.

Marking contents
Series
(Example)
5 7 8 10 11 14
Varister voltage (ERZE05A□□□) (ERZE07A□□□) (ERZE08A□□□) (ERZE10A□□□) (ERZE11A□□□) (ERZE14A□□□)

ZNR ZNR ZNR ZNR ZNR ZNR


201 or more E□□□ E7□□□ E8□□□ E10□□□ E11□□□ E14□□□
○◆◇ ○◆◇ ○◆◇ ○◆◇ ○◆◇ ○◆◇

Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
27
D type / E series
Performance characteristics
Characteristics Test methods / description Specifications

Electrical measurements (initial/after tests) shall be conducted at temperature of 5 to


Standard test condition
35℃, relative humidity of maximum 85 %. ―
The voltage betwen two terminals with the specified measuring current 1mA DC
Varistor voltage applied is called V1 or V1mA. The measurement shall be made as fast as possible to
avoid heat affection.

Maximum The maximum sinusoidal RMS voltage or maximum DC voltage that can be applied
allowable voltage continuously.
The maximum voltage between two terminals with the specified
standard impulse current (8/20 μs) illustrated below applied.

100
90
Current (%)

Clamping voltage
50

To meet the
10
0 specified value.
8 μs Time
20 μs

Rated power The power that can be applied in the specified ambient temperature.

The maximum energy within the varistor voltage change of ±10 % when a single
Maximum energy
impulse current of 2 ms or 10/1000 μs is applied.

The maximum current within the varistor voltage change of ±10 % when a standard
Maximum 2times
peak current
impulse current of 8/20 μs is applied two times with an interval of 5 minutes.
(Withstanding
Electrical

surge
The maximum current within the varistor voltage change of ±10 % with a single
current) 1time
standard impulse current of 8/20 μs is applied.

Temperature coefficient of V1mA at 85℃–V1mA at 25℃ 1


varistor voltage
× 100(%/℃) 0 to ‒0.05 %/ ℃ max.
V1mA at 25℃ 60

Capacitance shall be measured at 1 kHz ±10 %, 1 Vrms max. To meet the


Capacitance
(1 MHz ±10 % below 100 pF), 0 V bias and 20±2℃. specified value.

Withstanding voltage AC 1500 Vrms shall be applied between both terminals of the specimen connected
No breakdown
(Body insulation) together and metal foil closely wrapped round its body for 1 minute.

The change of VC shall be measured after the impulse current listed below is applied
10000 or 100000 times continuously with the interval of 10 seconds at room
temperature.

Item Impulse Life(Ⅰ) Impulse Life(Ⅱ)


4
Times ×10 Times ×105 Times

Part No. Current Impulse Current


Impulse life ERZE05A201 to ERZE05A471 50 A (8/20 μs) 35 A (8/20 μs) ΔV1mA/V1mA ≦ 0 to +20%

ERZE07A201 to ERZE07A471 100 A (8/20 μs) 70 A (8/20 μs)

ERZE08A201 to ERZE08A751 150 A (8/20 μs) 85 A (8/20 μs)

ERZE10A201 to ERZE10A112 170 A (8/20 μs) 90 A (8/20 μs)

ERZE11A201 to ERZE11A112 200 A (8/20 μs) 110 A (8/20 μs)

ERZE14A201 to ERZE14A112 250 A (8/20 μs) 120 A (8/20 μs)

Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
28
D type / E series
Performance characteristics
Characteristics Test methods / description Specifications

After gradually applying the force specified below and keeping the unit fixed for 10
seconds, the terminal shall be visually examined for any damage.
Robustness of
terminations
Terminal diameter Force
(Tensile)
ø0.6 mm, ø0.8 mm 9.8 N
ø1.0 mm 19.6 N

The unit shall be secured with its terminal kept vertical and the force specified below
shall be applied in the axial direction. The terminal shall gradually be bent by 90 ° in
one direction, then 90 ° in the opposite direction, and again back to the original No remarkable mechanical
Robustness of position. The damage of the terminal shall be visually examined. damage
terminations
(Bending)
Terminal diameter Force
Mechanical

ø0.6 mm, ø0.8 mm 4.9 N


ø1.0 mm 9.8 N

After repeadly applying a single harmonic vibration (amplitude: 0.75 mm, double
amplitude: 1.5 mm) with 1 minute vibration frequency cycles (10 Hz to 55 Hz to 10 Hz)
Vibration
to each of three perpendicular directions for 2 hours. Thereafter, the unit shall be
visually examined.

Approximately 95 %
After dipping the terminals to a depth of approximately 3 mm from the body in a of the termainals shall
Solderability
soldering bath of 235±5℃ for 2±0.5 seconds, the terminal shall be visually examined. be covered with new
solder uniformly.

After each lead shall be dipped into a solder bath having a temperature
of 260±5℃ to a point 2.0 to 2.5 mm from the body of the unit, using
Resistance to
soldering heat
shielding board (t=1.5 mm), be held there for 10±1 s and then be stored ΔV1mA/V1mA ≦ ±5 %
at room temperature and normal humidity for 1 to 2 hours. The change of
VCmA and mechanical damages shall be examined.

The specimen shall be subjected to 125±2℃ for 1000 hours in a thermostatic bath
High temperature
storage/Dry heat
without load and then stored at room temperature and normal humidity for 1 to 2 hours. ΔV1mA/V1mA ≦ ±5 %
Thereafter, the change of VCmA shall be measured.

The specimen shall be subjected to 40±2℃, 90 to 95 % RH for 1000 hours without


Humidity load and then stored at room temperature and normal humidity for 1 to 2 hours. ΔV1mA/V1mA ≦ ±5 %
Thereafter, the change of VCmA shall be measured.
The temperature cycle shown below shall be repeated five cycles and then stored at
room temperature and normal humidity for 1 to 2 hours. The change of VCmA and
mechanical damage shall be examined.

Step Temperature (℃) Period (minutes) ΔV1mA/V1mA ≦ ±5 %


Temperature cycle 1 –40±3 30±3 No remarkable
Environmental

mechanical damage
2 Room temperature 15±3
3 125±2 30±3
4 Room temperature 15±3

After being continuously applied the Maximum Allowable Voltage at 85±2℃ for 1000
High temperature
hours, the specimen shall be stored at room temperature and normal humidity for 1 to
load/Dry heat load
2 hours. Thereafter, the change of VCmA shall be measured.
ΔV1mA/V1mA ≦ ±10 %
The specimen shall be subjected to 40±2℃, 90 to 95 % RH and the
Damp heat load/ Maximum Allowable Voltage for 1000 hours and then stored at room
Humidity load temperature and normal humidity for 1 to 2 hours. Thereafter, the change of VCmA
shall be measured.

The specimen shall be subjected to –40±2℃ without load for 1000 hours and then
Low temperature
storage/Cold
stored at room temperature and normal humidity for 1 to 2 hours. Thereafter, the ΔV1mA/V1mA ≦ ±5 %
change of VCmA shall be measured.

Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20

29
D type / E series
Minimum quantity / Packing unit
Minimum
Packing quantity Carton (about)
Product Series / Type Part number quantity
/ Packing unit
in carton L×W×H (mm)
ERZE05A201 to 471 100 10000 210×340×180
ERZE07A201 to 391 50 3000 210×340×110
ERZE07A431 to 621 50 3000 210×340×110
ERZE08A201 to 331 50 3000 210×340×110
ERZE08A361 to 511 50 3000 210×340×110
ERZE08A561 to 751 50 2000 210×340×110
ERZE10A201 to 241 50 3000 210×340×110
Straight leads
ERZE10A271 to 431 50 3000 210×340×110
<Bulk>
ERZE10A471 to 112 50 2000 210×340×110
ERZE11A201 to 361 50 3000 210×340×110
ERZE11A391 to 561 50 2000 210×340×110
ERZE11A621 to 112 50 1000 210×340×110
ERZE14A201 to 221 50 2000 210×340×110
ERZE14A241 to 431 50 2000 210×340×110
ERZE14A471 to 112 50 1000 210×340×110
ERZE05A(B)201CS to 471CS 100 10000 210×340×180
ERZE07A(B)201CS to 391CS 100 4000 210×340×110
ERZE07A(B)431CS to 621CS 50 4000 210×340×110
ERZE08A(B)201CS to 331CS 100 4000 210×340×110
ERZE08A(B)361CS to 511CS 50 4000 210×340×110
Leads cut type ERZE08A(B)561CS to 751CS 50 3000 210×340×110
<Bulk> ERZE10A(B)201CS to 241CS 100 4000 210×340×110
ERZE10A(B)271CS to 431CS 50 4000 210×340×110
ERZE10A(B)471CS to 112CS 50 3000 210×340×110
ERZE11A(B)201CS to 361CS 50 3000 210×340×110
ERZE11A(B)391CS to 561CS 50 2000 210×340×110
ERZE11A(B)621CS to 112CS 50 2000 210×340×110
Varistors ERZE05E201 to 471 1000 10000 400×360×260
D type
(ZNR Surge ERZE07E201 to 271 1000 10000 400×360×260
E series
Absorber) ERZE07E331 to 471 1000 10000 470×360×260
ERZE07E511 to 621 500 5000 400×360×260
ERZE08E201 to 271 1000 5000 360×310×320
ERZE08E331 to 431 1000 5000 360×310×320
ERZE08E471 to 511 1000 5000 360×310×320
Straight leads
ERZE08E561 to 751 500 2500 360×270×320
and taped
ERZE10E201 to 241 1000 5000 360×310×320
ERZE10E271 to 471 1000 5000 360×310×320
ERZE10E511 to 561 1000 5000 360×310×320
ERZE10E621 to 112 500 2500 360×270×320
ERZE11E201 to 271 1000 5000 360×310×320
ERZE11E331 to 511 1000 5000 360×310×320
ERZE11E561 to 112 500 2500 360×270×320
ERZE05F201 to 471 1000 10000 400×360×260
ERZE07F201 to 271 1000 10000 400×360×260
ERZE07F331 to 471 1000 10000 470×360×260
ERZE07F511 to 621 500 5000 400×360×260
ERZE08F201 to 271 1000 5000 360×310×320
ERZE08F331 to 431 1000 5000 360×310×320
ERZE08F471 to 511 1000 5000 360×310×320
Crimped lead
ERZE08F561 to 751 500 2500 360×270×320
and taped
ERZE10F201 to 241 1000 5000 360×310×320
ERZE10F271 to 471 1000 5000 360×310×320
ERZE10F511 to 561 1000 5000 360×310×320
ERZE10F621 to 112 500 2500 360×270×320
ERZE11F201 to 271 1000 5000 360×310×320
ERZE11F331 to 511 1000 5000 360×310×320
ERZE11F561 to 112 500 2500 360×270×320
Part No., quantity and country of origin are designated on outer packages in English.
※Please contact local sales office about packing specifications.

Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 27-Jan-23
30
Varistors (ZNR Surge Absorber)
D type
E-S1 series

Varistors (ZNR Surge Absorber), Series E-S1, improves E series


products with high capability for absorbing transient overvoltage
in a compact size, suitable for surge protection at high
temperature.

Features
●Large withstanding surge current capability in compact sizes
●Withstanding surge current at max. 125 °C
●Large “Energy Handling Capability” absorbing transient overvoltages in compact sizes
●Wide range of varistor voltages
●RoHS compliant

Recommended applications
●Transistor, diode, IC, thyristor or triac semiconductor protection
●Surge protection in consumer electronic equipment
●Surge protection in communication, measuring or controller electronics
●Surge protection in electronic home appliances, gas or petroleum appliances

Applicable standards
●UL1449 (VZCA2/UL, VZCA8/C-UL)
●VDE IEC61051-1,-2,-2-2,IEC60950-1 Annex.Q,IEC62368-1 G8.2
●CQC (GB/T10193, GB/T10194, GB4943.1, GB8898)

Refer to "Standard Products" , and "Application Note for Safety Standards" , for the details.

■As for handling precautions and minimum quantity / Packing unit


please see related information.

Explanation of part numbers


1 2 3 4 5 6 7 8 9 10 11 12

E R Z E A S 1
Product code

Code Series Lead configuration Norminal varistor voltage Code Design


Code
E11 E11-S1 Configuration Packaging The first two digits are significant S1 Long lead type
E14 E14-S1 A Straight Lead Bulk figures and the third one denotes the SC Lead cut type
number of zeros following.

Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
31
D type / E11-S1 series
Reference guide to standard products
Varistor Clamping Maximum
Applicable Maximum
Voltage Voltage Peak Current
Standards Allowable Voltage
Part No. at 1 mA at 8/20 μs at 8/20 μs (A)
Type ACrms DC max. lp 85℃ 125℃ 125℃
Approvals (V)
name (V) (V) (V) (A) 1 time 1time 2 times
200
ERZE11A201S1 E11201 ○☆★◇◆ 130 170 340 50 6000 5000 4500
(185 to 225)

220
ERZE11A221S1 E11221 ○☆★◇◆ 140 180 360 50 6000 5000 4500
(198 to 242)

240
ERZE11A241S1 E11241 ○☆★◇◆ 150 200 395 50 6000 5000 4500
(216 to 264)

270
ERZE11A271S1 E11271 ○☆★◇◆ 175 225 455 50 6000 5000 4500
(247 to 303)

330
ERZE11A331S1 E11331 ○☆★◇◆ 210 270 545 50 6000 5000 4500
(297 to 363)

360
ERZE11A361S1 E11361 ○☆★◇◆ 230 300 595 50 6000 5000 4500
(324 to 396)

390
ERZE11A391S1 E11391 ○☆★◇◆ 250 320 650 50 6000 5000 4500
(351 to 429)

430
ERZE11A431S1 E11431 ○☆★◇◆ 275 350 710 50 6000 5000 4500
(387 to 473)

470
ERZE11A471S1 E11471 ○☆★◇◆ 300 385 775 50 6000 5000 4500
(423 to 517)

510
ERZE11A511S1 E11511 ○☆★◇◆ 320 410 845 50 6000 5000 4500
(459 to 561)

560
ERZE11A561S1 E11561 ○☆★◇◆ 350 450 930 50 6000 5000 4500
(504 to 616)

620
ERZE11A621S1 E11621 ○☆★◇◆ 385 505 1025 50 5000 5000 4500
(558 to 682)

680
ERZE11A681S1 E11681 ○☆★◇◆ 420 560 1120 50 5000 5000 4500
(612 to 748)

750
ERZE11A751S1 E11751 ○☆★◇◆ 460 615 1240 50 5000 5000 4500
(675 to 825)

820
ERZE11A821S1 E11821 ○☆★◇◆ 510 670 1355 50 5000 5000 4500
(738 to 902)

910
ERZE11A911S1 E11911 ○☆★◇◆ 550 745 1500 50 5000 5000 4500
(819 to 1001)

1000
ERZE11A102S1 E11102 ○☆★◇◆ 625 825 1650 50 5000 5000 4500
(900 to 1100)

1100
ERZE11A112S1 E11112 ○☆★◇◆ 680 895 1815 50 5000 5000 4500
(990 to 1210)

Maximum Allowable Voltage and Maximum Peak Current at 8/20 μs(A) at 125 °C
○ : UL1449 (VZCA2/UL, VZC A8/C-UL), ☆ : VDE (IEC61051-1, -2, -2-2), ★ : VDE (IEC60950-1 Annex.Q,IEC62368-1 G8.2),
◇ : CQC (GB/T10193, GB/T10194), ◆ : CQC (GB4943.1, GB8898)
※Approval number (File No.) of safety regulations are subject to revision without notice. Ask factory for a copy of the latest file No.

Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
32
D type / E11-S1 series
Ratings and characteristics
●Operating temperature range : ‒40 to 125 ℃ ●Storage temperature range : ‒40 to 125 ℃

Clamping Maximum peak current


Varistor Maximum Maximum energy
voltage Rated at 8/20 μs Capacitance
Voltage allowable (max.)
(max.) power 10/1000 at 1 kHz
Part No. at 1 mA voltage 2 ms
85 ℃ 125 ℃1 125 ℃ 2
*lp μs 1 time time times

ACrms DC
(V) (V) (W) (J) (J) (A) (A) (A) (pF)
(V) (V)
ERZE11A201S1 200(185 to 225) 130 170 340 0.6 70 50 6000 5000 4500 690
ERZE11A221S1 220(198 to 242) 140 180 360 0.6 78 55 6000 5000 4500 660
ERZE11A241S1 240(216 to 264) 150 200 395 0.6 84 60 6000 5000 4500 620
ERZE11A271S1 270(247 to 303) 175 225 455 0.6 99 70 6000 5000 4500 580
ERZE11A331S1 330(297 to 363) 210 270 545 0.6 115 80 6000 5000 4500 520
ERZE11A361S1 360(324 to 396) 230 300 595 0.6 130 90 6000 5000 4500 480
ERZE11A391S1 390(351 to 429) 250 320 650 0.6 140 100 6000 5000 4500 450
ERZE11A431S1 430(387 to 473) 275 350 710 0.6 155 110 6000 5000 4500 400
ERZE11A471S1 470(423 to 517) 300 385 775 0.6 175 125 6000 5000 4500 360
ERZE11A511S1 510(459 to 561) 320 410 845 0.6 190 136 6000 5000 4500 310
ERZE11A561S1 560(504 to 616) 350 450 930 0.6 190 136 6000 5000 4500 310
ERZE11A621S1 620(558 to 682) 385 505 1025 0.6 190 136 5000 5000 4500 300
ERZE11A681S1 680(612 to 748) 420 560 1120 0.6 190 136 5000 5000 4500 290
ERZE11A751S1 750(675 to 825) 460 615 1240 0.6 210 150 5000 5000 4500 280
ERZE11A821S1 820(738 to 902) 510 670 1355 0.6 235 165 5000 5000 4500 260
ERZE11A911S1 910(819 to 1001) 550 745 1500 0.6 255 180 5000 5000 4500 240
ERZE11A102S1 1000(900 to 1100) 625 825 1650 0.6 280 200 5000 5000 4500 220
ERZE11A112S1 1100(990 to 1210) 680 895 1815 0.6 310 220 5000 5000 4500 200
✽Ip Measuring current of clamping voltage : 50 A

Dimensions in mm (not to scale)


Unit : mm

Part No. D max. T max. F±1.0 A max. L±1.0


ERZE11A201S1 13.0 5.2 7.5 17.0 1.9
ERZE11A221S1 13.0 5.3 7.5 17.0 2.0
ERZE11A241S1 13.0 5.4 7.5 17.0 2.1
ERZE11A271S1 13.0 5.6 7.5 17.0 2.3
ERZE11A331S1 13.0 5.9 7.5 17.0 2.6
ERZE11A361S1 13.0 6.1 7.5 17.0 2.8
ERZE11A391S1 13.0 6.2 7.5 17.0 2.9
ERZE11A431S1 13.0 6.4 7.5 17.0 3.1
ERZE11A471S1 13.0 6.6 7.5 17.0 3.3 D
T
ERZE11A511S1 13.0 6.8 7.5 17.0 3.5
ERZE11A561S1 13.0 7.2 7.5 17.0 3.8
A

ERZE11A621S1 14.0 7.5 7.5 18.0 4.2


ERZE11A681S1 14.0 7.8 7.5 18.0 4.5 L
ERZE11A751S1 14.0 8.2 7.5 18.0 4.9
20.0 min.

ERZE11A821S1 14.0 8.5 7.5 18.0 5.2 F


ERZE11A911S1 14.0 9.0 7.5 18.0 5.7
ø0.8 F
ERZE11A102S1 14.0 9.5 7.5 18.0 6.2
ERZE11A112S1 14.0 10.1 7.5 18.0 6.8

Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20

33
D type / E11-S1 series
Typical characteristics
Voltage vs. Current Impulse Derating (Relation between
impulse width and impulse current multiple)

ERZE11A201S1 to ERZE11A511S1 ERZE11A201S1 to ERZE11A511S1


10000
Max.Leakage 2 times:5 min. interval
Current Max.Clamping Voltage
up to 10 times:2 min. interval
2000 up to 106 times : 10 sec. interval

511
471
431
471 391
361
431
1000 391
331
271
900 361 241 1000
800 221
201
700
600

500

Impulse Current(A)
400
Voltage(V)

300 100

200

100
331
90 10
221
80
70
60
Test current waveform
50 10–6 to 10–3 A: Direct current
10–1 to 104 A: 8/20 μs
40
30
10-6 10-5 10-4 10-3 10-2 10-1 100 101 102 103 104 105 120
100 1000 10000

Current(A) Impulse Width(μs)

ERZE11A561S1 to ERZE11A112S1 ERZE11A561S1 to ERZE11A112S1


5000 10000
Max.Leakage
Current Max.Clamping Voltage
2 times:5 min. interval
4000 up to 10 times:2 min. interval
up to 106 times : 10 sec. interval

3000
112
102

911
821 1000
2000 751
681

102 621
561
Impulse Current(A)

911
821
Voltage(V)

1000 100
900
800
700

600

500
10
400

300 Test current waveform


751
10–6 to 10–3 A: Direct current
10–1 to 104 A: 8/20 μs
681
621
200 1
10-6 10-5 10-4 10-3 10-2 10-1 100 101 102 103 104 105 20 100 1000 10000

Current(A) Impulse Width(μs)

Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
34
D type / E14-S1 series
Reference guide to standard products
Varistor Clamping Maximum
Applicable Maximum
voltage voltage peak current
standards allowable voltage
Part No. at 1 mA at 8/20 μs at 8/20 μs (A)
Type ACrms DC max. lp 85℃ 125℃ 125℃
Approvals (V)
name (V) (V) (V) (A) 1 time 1time 2 times
200
ERZE14A201S1 E14201 ○☆★◇◆ 130 170 340 100 10000 7500 6500
(185 to 225)

220
ERZE14A221S1 E14221 ○☆★◇◆ 140 180 360 100 10000 7500 6500
(198 to 242)

240
ERZE14A241S1 E14241 ○☆★◇◆ 150 200 395 100 10000 7500 6500
(216 to 264)

270
ERZE14A271S1 E14271 ○☆★◇◆ 175 225 455 100 10000 7500 6500
(247 to 303)

330
ERZE14A331S1 E14331 ○☆★◇◆ 210 270 545 100 10000 7500 6500
(297 to 363)

360
ERZE14A361S1 E14361 ○☆★◇◆ 230 300 595 100 10000 7500 6500
(324 to 396)

390
ERZE14A391S1 E14391 ○☆★◇◆ 250 320 650 100 10000 7500 6500
(351 to 429)

430
ERZE14A431S1 E14431 ○☆★◇◆ 275 350 710 100 10000 7500 6500
(387 to 473)

470
ERZE14A471S1 E14471 ○☆★◇◆ 300 385 775 100 10000 7500 6500
(423 to 517)

510
ERZE14A511S1 E14511 ○☆★◇◆ 320 410 845 100 10000 7500 6500
(459 to 561)

560
ERZE14A561S1 E14561 ○☆★◇◆ 350 450 930 100 10000 7500 6500
(504 to 616)

620
ERZE14A621S1 E14621 ○☆★◇◆ 385 505 1025 100 7500 7500 6500
(558 to 682)

680
ERZE14A681S1 E14681 ○☆★◇◆ 420 560 1120 100 7500 7500 6500
(612 to 748)

750
ERZE14A751S1 E14751 ○☆★◇◆ 460 615 1240 100 7500 7500 6500
(675 to 825)

820
ERZE14A821S1 E14821 ○☆★◇◆ 510 670 1355 100 7500 7500 6500
(738 to 902)

910
ERZE14A911S1 E14911 ○☆★◇◆ 550 745 1500 100 7500 7500 6500
(819 to 1001)

1000
ERZE14A102S1 E14102 ○☆★◇◆ 625 825 1650 100 7500 7500 6500
(900 to 1100)

1100
ERZE14A112S1 E14112 ○☆★◇◆ 680 895 1815 100 7500 7500 6500
(990 to 1210)

Maximum Allowable Voltage and Maximum Peak Current at 8/20 μs(A) at 125 °C
○ : UL1449 (VZCA2/UL, VZC A8/C-UL), ☆ : VDE (IEC61051-1, -2, -2-2), ★ : VDE (IEC60950-1 Annex.Q,IEC62368-1 G8.2),
◇ : CQC (GB/T10193, GB/T10194), ◆ : CQC (GB4943.1, GB8898)
※Approval number (File No.) of safety regulations are subject to revision without notice. Ask factory for a copy of the latest file No.

Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20

35
D type / E14-S1 series
Ratings and characteristics
●Operating temperature range : ‒40 to 125 ℃ ●Storage temperature range : ‒40 to 125 ℃
Clamping Maximum peak current
Varistor Maximum Maximum energy
voltage Rated at 8/20 μs Capacitance
voltage allowable (max.)
(max.) power
Part No. at 1 mA voltage 10/1000
2 ms
85 ℃ 125 ℃ 125 ℃ 2 at 1 kHz
*lp μs 1 time 1time times
ACrms DC
(V) (V) (W) (J) (J) (A) (A) (A) (pF)
(V) (V)
ERZE14A201S1 200(185 to 225) 130 170 340 1.0 140 100 10000 7500 6500 1300
ERZE14A221S1 220(198 to 242) 140 180 360 1.0 155 110 10000 7500 6500 1200
ERZE14A241S1 240(216 to 264) 150 200 395 1.0 168 120 10000 7500 6500 1100
ERZE14A271S1 270(247 to 303) 175 225 455 1.0 190 135 10000 7500 6500 1000
ERZE14A331S1 330(297 to 363) 210 270 545 1.0 228 160 10000 7500 6500 900
ERZE14A361S1 360(324 to 396) 230 300 595 1.0 255 180 10000 7500 6500 900
ERZE14A391S1 390(351 to 429) 250 320 650 1.0 275 195 10000 7500 6500 800
ERZE14A431S1 430(387 to 473) 275 350 710 1.0 303 215 10000 7500 6500 800
ERZE14A471S1 470(423 to 517) 300 385 775 1.0 350 250 10000 7500 6500 750
ERZE14A511S1 510(459 to 561) 320 410 845 1.0 382 273 10000 7500 6500 700
ERZE14A561S1 560(504 to 616) 350 450 930 1.0 382 273 10000 7500 6500 700
ERZE14A621S1 620(558 to 682) 385 505 1025 1.0 382 273 7500 7500 6500 650
ERZE14A681S1 680(612 to 748) 420 560 1120 1.0 382 273 7500 7500 6500 600
ERZE14A751S1 750(675 to 825) 460 615 1240 1.0 420 300 7500 7500 6500 530
ERZE14A821S1 820(738 to 902) 510 670 1355 1.0 460 325 7500 7500 6500 500
ERZE14A911S1 910(819 to 1001) 550 745 1500 1.0 510 360 7500 7500 6500 400
ERZE14A102S1 1000(900 to 1100) 625 825 1650 1.0 565 400 7500 7500 6500 400
ERZE14A112S1 1100(990 to 1210) 680 895 1815 1.0 620 440 7500 7500 6500 350

✽Ip Measuring current of clamping voltage : 100 A

Dimensions in mm (not to scale)


Unit : mm

Part No. D max. T max. F±1.0 A max. L±1.0


ERZE14A201S1 16.5 5.2 10.0 20.0 2.1
ERZE14A221S1 16.5 5.3 10.0 20.0 2.2
ERZE14A241S1 16.5 5.4 10.0 20.0 2.3
ERZE14A271S1 16.5 5.6 10.0 20.0 2.5
ERZE14A331S1 16.5 5.9 10.0 20.0 2.8
ERZE14A361S1 16.5 6.1 10.0 20.0 3.0
ERZE14A391S1 16.5 6.2 10.0 20.0 3.1
ERZE14A431S1 16.5 6.4 10.0 20.0 3.3
ERZE14A471S1 16.5 6.6 10.0 20.0 3.5 D
T
ERZE14A511S1 16.5 6.8 10.0 20.0 3.7
ERZE14A561S1 16.5 7.2 10.0 20.0 4.0
A

ERZE14A621S1 17.5 7.5 10.0 20.5 4.4


ERZE14A681S1 17.5 7.8 10.0 20.5 4.7 L
ERZE14A751S1 17.5 8.2 10.0 20.5 5.1
20.0 min.

ERZE14A821S1 17.5 8.5 10.0 20.5 5.4


F
ERZE14A911S1 17.5 9.0 10.0 20.5 5.9
ø1.0 F
ERZE14A102S1 17.5 9.5 10.0 20.5 6.4
ERZE14A112S1 17.5 10.1 10.0 20.5 7.2

Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
36
D type / E14-S1 series
Typical characteristics
Voltage vs. Current Impulse Derating (Relation between
impulse width and impulse current multiple)

ERZE14A201S1 to ERZE14A511S1 ERZE14A201S1 to ERZE14A511S1


10000
Max.Leakage 2 times:5 min. interval
Current Max.Clamping Voltage
up to 10 times:2 min. interval
2000 511 up to 106 times : 10 sec. interval

471
471 431
431 391
391 361
1000 361 331
1000
900 271
800 241
700 221
201
600

500

Impulse Current (A)


400
Voltage(V)

100
300

200

100 10
90
80
241
70 331
221
60
50 Test current waveform
10–6 to 10–3 A: Direct current
10–1 to 104 A: 8/20 μs
40
30 1
10-6 10-5 10-4 10-3 10-2 10-1 100 101 102 103 104 105 20 100 1000 10000

Current(A) Impulse Width(μs)

ERZE14A561S1 to ERZE14A112S1 ERZE14A561S1 to ERZE14A112S1

5000 10000
Max.Leakage
Current Max.Clamping Voltage 2 times:5 min. interval
4000 up to 10 times:2 min. interval
up to 106 times : 10 sec. interval

3000 112
102
911
821
1000
751
2000
681
621
561

102
Impulse Current (A)

911
Voltage(V)

821
1000 100
900
800

700

600

500
10
400

300
751 Test current waveform
681 10–6 to 10–3 A: Direct current
10–1 to 104 A: 8/20 μs
621

200 1
10-6 10-5 10-4 10-3 10-2 10-1 100 101 102 103 104 105 20 100 1000 10000

Current(A) Impulse Width (μs)

Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
37
D type / E-S1 series (Leads cut type)
Straight leads cut type (Bulk type)
※ Ratings and characteristics is refer to bulk standard type.

Dimensions in mm (not to scale)


D T**

ød
B

F L*

notes ✽ Dimension “L”: Conforms to each individtual specification.


✽✽ Dimension “T”: Conforms to each individual specification.

Unit : mm

Series E11-S1 E14-S1


Varister Voltage
Symbol 201 to 561 621 to 112 201 to 561 621 to 112
D 13.0 max 14.0 max 16.5 max 17.5 max
A 17.0 max 18.0 max 20.0 max 20.5 max
F 7.5±1.0 7.5±1.0 10.0±1.0 10.0±1.0
+0.08 +0.08 +0.1 +0.1
ød 0.80 -0.05
0.80 -0.05
1.00 -0.05
1.00 -0.05

B 4.0±1.0 4.0±1.0 4.0±1.0 4.0±1.0


Standard
Products Part No. ERZE11A□□□SC ERZE14A□□□SC

Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
38
D type / E-S1 series
Application Note for Safety Standards (For Series E-S1)
● Approvals products lists in "Reference Guide to Standard Products."
● UL and VDE : Registered in "Type name", it isn’t registered in "Panasonic Part No."
● CQC : Registered in "Panasonic Part No."
● "Rated Voltages" are specified for UL recognized components in list shown below.

The AC rated voltage and maximum allowable voltage


Maximum Allowable Voltage Rated Voltage (Vrms)
Type name
ACrms (V) DC (V) UL1449
E✽201 130 170 118
E✽221 140 180 127
E✽241 150 200 136
E✽271 175 225 159
E✽331 210 270 189
E✽361 230 300 209
E✽391 250 320 227
E✽431 275 350 250
E✽471 300 385 272
E✽511 320 410 291
E✽561 350 450 320
E✽621 385 505 350
E✽681 420 560 381
E✽751 460 615 418
E✽821 510 670 463
E✽911 550 745 500
E✽102 625 825 568
E✽112 680 895 600

✽:11 series is 11, 14 series is 14

Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
39
D type / E-S1 series
Explanation of the contents
Mark Explanation of the content
Abbreviation of
E11□□□ □□□
Part No.
E14□□□ (Type name) Nominal varistor volage

Marking Factory identication None:Japan


〇 mark Q:Indonesia

2019 : 9, 2020 : K, 2021 : A


◆*1 Year code
2022 : B, 2023 : C, 2024 : D
Jan : 1 to Sep : 9,
◇ Monthly code
Oct. : 0, Nov. : N,Dec. : D
H Identication Code
UL Recognized Components Mark

*1: If the 10's digit of a Christian year is an even year, as an end abbreviation,
an alphabetic character is used.
1 : A, 2 : B, 3 : C, 4 : D, 5 : E, 6 : F, 7 : G, 8 : H, 9 : J, 0 : K
If the 10's digit of a Christian year is an odd year, as an end abbreviation, a
number is used.

Marking contents
Series (Example)
Varister
11 14
voltage (ERZE11A□□□S1) (ERZE14A□□□S1)

ZNR ZNR
201 or more E11□□□ E14□□□
○◆◇H ○◆◇H

Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
40
D type / E-S1 series
Performance characteristics
Characteristics Test methods / description Specifications

Electrical measurements (initial/after tests) shall be conducted at temperature of 5 to


Standard test condition
35 ℃, relative humidity of maximum 85 %. ―
The voltage betwen two terminals with the specified measuring current 1mA DC
Varistor voltage applied is called V1 or V1mA. The measurement shall be made as fast as possible to
avoid heat affection.

Maximum The maximum sinusoidal RMS voltage or maximum DC voltage that can be applied
allowable voltage continuously. (max. 125 ℃)

The maximum voltage between two terminals with the specified


standard impulse current (8/20 μs) illustrated below applied.

100
90
Current (%)

Clamping voltage
50
To meet the
10
specified value.
0
8 μs Time
20 μs

Rated power The power that can be applied in the specified ambient temperature.

The maximum energy within the varistor voltage change of ±10 % when a single
Maximum energy
impulse current of 2 ms or 10/1000 μs is applied.

The maximum current within the varistor voltage change of ±10 % when a standard
Maximum 2times impulse current of 8/20 μs is applied two times with an interval of 5 minutes. (at max.
peak current 125 ℃)
(Withstanding
Electrical

surge The maximum current within the varistor voltage change of ±10 % with a single
current) 1time
standard impulse current of 8/20 μs is applied. (at max. 125 ℃)

Temperature coefficient V1 mA at 125 ℃–V1 mA at 25 ℃ 1


of varistor voltage
× 100(%/℃) 0 to ‒0.05 %/ ℃ max.
V1 mA at 25 ℃ 100

Capacitance shall be measured at 1 kHz ±10 %, 1 Vrms max. To meet the


Capacitance
(1 MHz ±10 % below 100 pF), 0 V bias and 20±2 ℃. specified value.

Withstanding voltage AC 1500 Vrms shall be applied between both terminals of the specimen connected
No breakdown
(Body Insulation) together and metal foil closely wrapped round its body for 1 minute.

The change of VC shall be measured after the impulse current listed below is applied
10000 or 100000 times continuously with the interval of 10 seconds at room
temperature.

Item Impulse Life(Ⅰ) Impulse Life(Ⅱ)


4
Times ×10 Times ×105 Times

Part No. Current Impulse Current


ΔV1 mA/V1 mA ≦
Impulse life ERZE11A201S1 to ERZE11A112S1 200 A (8/20 μs) 110 A (8/20 μs)
0 to +20%
ERZE14A201S1 to ERZE14A112S1 250 A (8/20 μs) 120 A (8/20 μs)

Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
41
D type / E-S1 series
Performance characteristics
Characteristics Test methods / description Specifications

After gradually applying the force specified below and keeping the unit fixed for 10
seconds, the terminal shall be visually examined for any damage.
Robustness of
terminations Terminal diameter Force
(Tensile) ø0.6 mm, ø0.8 mm 9.8 N
ø1.0 mm 19.6 N

The unit shall be secured with its terminal kept vertical and the force specified below
shall be applied in the axial direction. The terminal shall gradually be bent by 90 ° in
one direction, then 90 ° in the opposite direction, and again back to the original No remarkable mechanical
Robustness of position. The damage of the terminal shall be visually examined. damage
terminations
(Bending)
Terminal diameter Force
Mechanical

ø0.6 mm, ø0.8 mm 4.9 N


ø1.0 mm 9.8 N

After repeadly applying a single harmonic vibration (amplitude: 0.75 mm, double
amplitude: 1.5 mm) with 1 minute vibration frequency cycles (10 Hz to 55 Hz to 10 Hz)
Vibration
to each of three perpendicular directions for 2 hours. Thereafter, the unit shall be
visually examined.

Approximately 95 %
After dipping the terminals to a depth of approximately 3 mm from the body in a of the termainals shall
Solderability
soldering bath of 235±5 ℃ for 2±0.5 seconds, the terminal shall be visually examined. be covered with new
solder uniformly.

After each lead shall be dipped into a solder bath having a temperature
of 260±5 ℃ to a point 2.0 to 2.5 mm from the body of the unit, using
Resistance to
shielding board (t=1.5 mm), be held there for 10±1 s and then be stored ΔV1 mA/V1 mA ≦ ±5 %
soldering heat
at room temperature and normal humidity for 1 to 2 hours. The change of
VCmA and mechanical damages shall be examined.

The specimen shall be subjected to 125±2 ℃ for 1000 hours in a thermostatic bath
High temperature
without load and then stored at room temperature and normal humidity for 1 to 2 hours. ΔV1 mA/V1 mA ≦ ±5 %
storage/Dry heat
Thereafter, the change of VCmA shall be measured.

The specimen shall be subjected to 40±2 ℃, 90 to 95 % RH for 1000 hours without


Humidity load and then stored at room temperature and normal humidity for 1 to 2 hours. ΔV1 mA/V1 mA ≦ ±5 %
Thereafter, the change of VCmA shall be measured.
The temperature cycle shown below shall be repeated five cycles and then stored at
room temperature and normal humidity for 1 to 2 hours. The change of VCmA and
mechanical damage shall be examined.

Step Temperature (℃) Period (minutes) ΔV1 mA/V1 mA ≦ ±5 %


Temperature cycle 1 –40±3 30±3 No remarkable
Environmental

2 Room temperature 15±3 mechanical damage


3 125±2 30±3
4 Room temperature 15±3

After being continuously applied the Maximum Allowable Voltage at 125±2 ℃ for 1000
High temperature
hours, the specimen shall be stored at room temperature and normal humidity for 1 to 2
load/Dry heat load
hours. Thereafter, the change of VCmA shall be measured.
ΔV1 mA/V1 mA ≦ ±10 %
The specimen shall be subjected to 40±2 ℃, 90 to 95 % RH and the
Damp heat load/ Maximum Allowable Voltage for 1000 hours and then stored at room
humidity load temperature and normal humidity for 1 to 2 hours. Thereafter, the change of VCmA
shall be measured.

The specimen shall be subjected to –40±2 ℃ without load for 1000 hours and then
Low temperature
stored at room temperature and normal humidity for 1 to 2 hours. Thereafter, the ΔV1 mA/V1 mA ≦ ±5 %
storage/Cold
change of VCmA shall be measured.

Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
42
D type / E-S1 series
Minimum quantity / Packing unit

Minimum
Packing quantity Carton (about)
Product Series / Type Part number quantity
/ Packing unit
in carton L×W×H (mm)

ERZE11A201S1 to 361S1 50 3000 210×340×110


ERZE11A391S1 to 561S1 50 2000 210×340×110

Straight leads ERZE11A621S1 to 112S1 50 1000 210×340×110


<Bulk> ERZE14A201S1 to 221S1 50 2000 210×340×110
ERZE14A241S1 to 431S1 50 2000 210×340×110
Varistors D type ERZE14A471S1 to 112S1 50 1000 210×340×110
(ZNR Surge E-S1
Absorber) series ERZE11A201SC to 361SC 50 3000 210×340×110
ERZE11A391SC to 561SC 50 2000 210×340×110

Leads cut type ERZE11A621SC to 112SC 50 2000 210×340×110


<Bulk> ERZE14A201SC to 361SC 50 2000 210×340×110
ERZE14A391SC to 561SC 50 2000 210×340×110
ERZE14A621SC to 112SC 50 1000 210×340×110

Part No., quantity and country of origin are designated on outer packages in English.
※Please contact local sales office about packing specifications.

Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
43
Matters to Be Observed When Using This Product

Matters to Be Observed When Using This Product


(D-type : V series / SMD-type : HF・VF series)

Safety measures
An abnormal state for varistors (ZNR surge absorbers) of the D type/V series and SMD-Type/HF, VF Series (hereinafter
the product or "the surge absorber") that results from a problem with service conditions (materials used, the surrounding
environment, power conditions, circuit conditions, etc.) may cause a fire accident, electric shock accident, burn accident,
or product failure. Matters to note when handling this product will hereinafter be described. What is described below should
be checked sufficiently before the product is used.

■ Confirming rated capabilities


Use the surge absorber within the range of its rated capabilities. Each type of surge absorber has specified rated
capabilities including a maximum allowable circuit voltage, a surge current tolerance, an energy tolerance, an impulse
lifespan (surge lifespan), average pulse power, and a service temperature. Using the surge absorber under severe
service conditions that are beyond the rated capabilities causes degraded performance of the surge absorber or
destruction of a circuit element, which may lead to smoke generation, ignition, etc.

■ Take the following measures in order to avoid an accident caused by expected phenomenon.

(1) Destruction of the surge absorber may scatter its fractured pieces around. To protect other elements from these
pieces, set product in a case or shield it with a cover.
(2) Do not place the surge absorber near combustible materials (vinyl cable, resin mold, etc.). If avoiding the vicinity
of combustible materials is difficult, protect the combustible material with an incombustible cover.
(3) Surge absorber placed between lines
When the surge absorber is placed between lines, connect a normal type current fuse in series with the surge
absorber.
* See "Current fuse" in the "Circuit design and circuit board design" section.
(4) Surge absorber placed between a line and the ground
① When the surge absorber is placed between a line and the ground, even if the surge absorber short-circuits,
ground resistance will remain in the section between the line and the ground, leaving a possibility that the
current fuse won’t blow, in which case the outer sheath resin of the surge absorber may generate smoke or
ignite due to current flow. To prevent such a case, place an earth leakage breaker in a location closer to the
power supply than the surge absorber. When not using an earth leakage breaker, use a current fuse and
temperature fuse in series with each other.
* See Table 1 in the "Circuit design and circuit board design" section.
② When the surge absorber is placed between a live part and a metal case, it may cause electric shock if the
surge absorber short-circuits. To avoid this, ground the metal case or shield it to prevent direct contact with the
metal case.

■ In case the surge absorber should short-circuit and generate smoke or ignite, immediately cut off current flow
to the surge absorber.

■ Rated voltage for UL certification, etc.


To allow the surge absorber to meet leak current requirements, etc., a maximum allowable circuit voltage and rated
voltage are specified for the surge absorber.
When applying for UL certification, etc. of a device equipped with a surge absorber, ensure the working voltage of the
device does not exceed the rated voltage of the surge absorber.

■ An unexpected sharp rise in the working voltage, an incoming excessive surge, etc., may cause the surge absorber to
generate smoke or ignite.
In such a case, fire spreading through the device should be prevented to avoid expanded damage. To achieve this,
take a multi-protection measure, such as adopting fire-resistant materials that make up the outer shell components
and structural materials.

30-Jun-23
44
Matters to Be Observed When Using This Product

Use environments and cleaning conditions


■ Do not use the surge absorber in an outdoor environment where the surge absorber is exposed to sunlight.

■ Do not use the surge absorber in which direct sunlight hits the surge absorber or near a heating element where the
temperature of the surge absorber would rise above its working temperature.

■ Do not use the surge absorber in a place where the surge absorber is exposed to wind or rain or a highly humid place
where steam is emitted or dew concentrates.

■ Do not use the surge absorber in a place filled with dust or salt, in an atmosphere contaminated with a corrosive gas,
etc., or in liquids such as water, oil, chemical, or organic solvents.

■ Do not wash the surge absorber with a solvent (thinner, acetone, etc.) that damages the outer sheath resin.

Response to anomalies and handling conditions


Be careful not to drop the surge absorber on the floor, etc. The product is likely to suffer mechanical or electrical damage
when dropped on the floor. Avoid using such a product.

Reliability
A capacitor conforming to "AEC-Q200" refers to a capacitor having passed some or all of evaluation test items defined
in AEC-Q200.
To know the detailed specifications of each capacitor or specific evaluation test scores, please contact us.
We issue a delivery specification sheet for each product ordered. Please confirm the delivery specification sheet when
you place an order with us.

Circuit design and circuit board design


Meet the following requirements. Not following the requirements can result in a shorter lifespan of the surge absorber or its
failure.

■ Choose a surge absorber whose maximum allowable circuit voltage has a margin relative to the maximum voltage range
including source voltage fluctuations.
* See Table 1 in the "Circuit design and circuit board design" section.

■ When surges are applied intermittently to the surge absorber at short intervals (when pulses of voltages are applied in a
noise simulator test, etc.), make sure that the surge power does not exceed the maximum average pulse power of the surge
absorber.

■ The product numbers of recommended surge absorbers to choose are shown in Table 1.

(1) The case of placing the surge absorber between lines


When the source voltage is expected to rise temporarily due to unbalanced single-wire loads in a three-phase three-wire
connection configuration, a short circuit between a voltage line and a neutral line, loss of the neutral line, or resonance of
a capacitive load caused by switching on/off, use a surge absorber (varistor) indicated by "*" in Table 1.
(2) The case of placing the surge absorber between a line and the ground
Line-to-ground voltage may rise with a single-wire ground fault, etc. Use a recommended surge absorber in Table 1 that
is different from the surge absorber placed between lines. When the device is subjected to an insulation resistance test
(500 V DC), use a D-type surge absorber indicated by "**" in Table 1.
According to "Electrical Appliance Technical Standards" based on the Electrical Appliance and Material Safety Act, when
using a varistor voltage which would fail the insulation performance test, the surge absorber may be removed from the
device when being subjected to the test, depending on circuit test conditions.
* See attached table 4, appendix 4, "Electrical Appliance Technical Standards" based on the Electrical Appliance and
Material Safety Act.
When conducting a withstand voltage test (1000 V AC or 1200 V AC) of the device, use the recommended D type /
V series surge absorber indicated by "***" in Table 1.

30-Jun-23
45
Matters to Be Observed When Using This Product

■ Current fuse

(1) Select a surge absorber and the rated current for a current fuse to be used in a manner shown in the following table.
Confirm that no secondary accident arises when the surge absorber in an actual circuit breaks. Selected rated currents
of current fuses shown in the following table are exemplary one and may vary depending on circuit conditions used.
Confirm the rated current by a test, etc., before using the current fuse.

<Rated currents of current fuses for the D-type / V series surge absorber>
Standard
product number ERZV05D□□□ ERZV07D□□□ ERZV09D□□□ ERZV10D□□□ ERZV14D□□□ ERZV20D□□□
Rating
current
3 A max. 5 A max. 7 A max. 7 A max. 10 A max. 10 A max.

* Use the rated voltage of the current fuse that corresponds to the circuit voltage of a circuit including the current fuse.

<Rated current of a current fuse for the SMD-type / VF series surge absorber>
Standard
product number
ERZVF□M□□□
Rating current 5 A max.

* Use the rated voltage of the current fuse that corresponds to the circuit voltage of a circuit including the current fuse.
* For the HF series surge absorber, select the rated current of the fuse after confirming the way the fuse handles a load dump
surge and the protective coordination action it makes when the surge absorber is destroyed.

(2) Recommended parts where fuses are connected are shown in Table 1. When a load current to a protected device is so
large as to exceed the rated current of the fuse, however, connect the fuse in a location shown in the following diagram.

Current fuse
Power supply Protected
device
ZNR

■ Temperature fuse
When connecting the surge absorber to a temperature fuse, choose a connection method and a temperature fuse that allow
fine thermal coupling between the surge absorber and the temperature fuse.

30-Jun-23
46
Matters to Be Observed When Using This Product

Table 1 Application example of the product (ordinary application example)


Surge absorber placed between lines Surge absorber placed between a line and the ground

DC DC
Single-phase AC Single-phase AC
Current fuse ZNR1
Current fuse ZNR1 L
L
Protected
device
Protected N
device ZNR2
N

Thermal coupling Temperature fuse


Connection

Three-phase AC Three-phase AC
Current fuse
Current fuse ZNR3 ZNR3
ZNR3
Protected
Protected device
ZNR3
device

ZNR4
ZNR3
Thermal coupling Temperature fuse

Power supply Nominal varistor voltage Power supply Nominal varistor voltage
ZNR voltage ZNR voltage
[AC] D-type SMD-type [AC] D-type SMD-type
100 V 201 to 361* 201 to 361* 471 471
Varistor voltage selection

120 V 241 to 431* 241 to 431* 511 -


100 V
ZNR 1 200 V 471 to 621* 471 621* -
220 V
ZNR 3 220 V 471 to 621* 471 821 or higher** -
240 V 511、 621* - 182*** -
ZNR 2
380 V 751、 821* - 511 -
ZNR 4
621* -
230 V
821 or higher** -
182** -
112** -
380 V
182*** -
* Choose the element size while taking surge conditions into consideration.

Processing conditions
■ Do not apply vibration, impact (drop impact, etc.), or pressure strong enough to crack the outer sheath resin or absorber
body of the surge absorber.

■ When coating the surge absorber with a resin or embedding it in a resin mold, avoid using a resin that degrades the
surge absorber.

■ Do not bend or apply a force to the lead of a D-type surge absorber close to the outer sheath resin.

30-Jun-23
47
Matters to Be Observed When Using This Product

Mounting and storage conditions


■ When soldering the surge absorber, follow recommended soldering conditions shown in the following table so that
solder or the insulation material making up the surge absorber is not melted.

■ When making holes for mounting the surge absorber on the board, check the dimensions of the holes on the board,
referencing the central point of the interval between the leads.
Because the overall dimensional tolerance is large, forming the holes with high precision requires careful processing.

Soldering method Recommended conditions Mater to note

Flow soldering The D-type surge absorber should not be soldered by reflow
D-type 260 ℃, 10 seconds or less
(solder bath immersion method) soldering.
A high component mounting density may lead to poor
Flow soldering
260 ℃, 10 seconds or less solderability. In such a case, consider vent hole formation.
(solder bath immersion method)
SMD-type
Reflow soldering Refer to the recommended When a land is excessively larger than the terminal surface of
(controlled atmosphere heating soldering temperature a component, the component may shift position when solder is
method) profile. melted.

Note 1: Soldering the surge absorber under soldering conditions different from the recommended soldering
conditions requires extra checking to ensure it won’t cause any problems.
Additional soldering is allowed only once. It must be done within 5 seconds, with the soldering iron
temperature kept at 400 ℃ or lower.
Note 2: A temperature profile may include a large error, depending on the measurement method used.
Be careful in such cases.
Note 3: Board temperatures vary depending on the sizes of boards and mounting densities. Confirm the
temperature for each type of board.
Heat resistance range of the
product in the reflow soldering
<Recommended soldering temperature profile>
process
260
Flow soldering Reflow soldering
(solder bath immersion method) (controlled atmosphere heating method) 250

Temperature (°C)
Terminal temperature (°C)

Soldering part
Preheating part Cooling part Cooling part 240
Temperature (°C)

Temperature-rising part (I)

Preheating part
230

220

210
Temperature-rising part (II)

Main heating part 200


0 10 20 30 40 50 60
Time Time Time (s)

Normal temperature Temperature-rising Normal temperature to


Preheating part 120 seconds or less 30 to 60 seconds
to 130 ℃ part I preheating temperature

Soldering part 260 ℃ or less 10 seconds or less Preheating part 150 ℃ to 180 ℃ 60 to 120 seconds

Gradual cooling Temperature-rising


Cooling part Preheating temperature to 200 ℃ 2 to 6 ℃ per second
(cooling under the normal temperature) part II
Main heating Refer to the heat resistance range of the product
part in the reflow soldering process.

Cooling part 200 ℃ to 100 ℃ 1 to 4 ℃ per second

* Do not perform reflow soldering more than two times.

■ Mounting the surge absorber (SMD-type)


When mounting the surge absorber on the board, make sure that no excessive impact or load, such as pressure from a
suction nozzle for mounting the absorber, positional shift, or mechanical impact/stress caused by a positioning of the
absorber, is applied to the surge absorber. There are cases where the surge absorber shifts from its intended position
when mounted on the board. In such cases, consider a method of bonding the board and the outer sheath resin together.

■ Do not keep the product in a high-temperature or high-humidity condition. Keep the surge absorber in a room with
a temperature of 40 ℃ or lower and a relative humidity of 75% or lower and use the surge absorber within two years of
storage. Check the solderability of a surge absorber stored for a long period (two years or more) before using the surge
absorber.

■ Keep the surge absorber in a place where no corrosive gas atmosphere (hydrogen sulfide, sulfurous acid, chlorine,
ammonia, etc.) is present.

■ Keep the surge absorber in a place where the surge absorber is protected from direct sunlight, dew concentration, etc.

30-Jun-23
48
Varistors (ZNR Surge Absorber)
D type
V series For Varistor Voltages ranging from 200 to 1100V, kindly also consider corresponding, smaller E
Series devices with better performance for their size. → Please click here

Features
●Large withstanding surge current capability in compact sizes
●Large “Energy Handling Capability” absorbing transient overvoltages in compact sizes
●Wide range of varistor voltages
●RoHS compliant

Recommended applications
●Transistor, diode, IC, thyristor or triac semiconductor protection
●Surge protection in consumer electronic equipment
●Surge protection in communication, measuring or controller electronics
●Surge protection in electronic home appliances, gas or petroleum appliances

Applicable standards
●UL1449 (VZCA2/UL, VZCA8/C-UL)
●VDE IEC61051-1,-2,-2-2,IEC60950-1 Annex.Q, IEC62368-1 G8.2
●CSA C22.2 N 269.5
●CQC (GB/T10193, GB/T10194, GB4943.1, GB8898)

Refer to "Standard Products" , and "Application Note for Safety Standards" , for the details.

■As for handling precautions and minimum quantity / Packing unit


please see related information.

Explanation of part numbers (Bulk)


1 2 3 4 5 6 7 8 9 10 11 12

E R Z V D
Product code Series Design No.

Element Element Lead Norminal varistor voltage


Code Code Code
size size configuration The first two digits are significant
05 ø5 mm 10 ø10 mm D Straight lead figures and the third one denotes the
07 ø7 mm 14 ø14 mm V Crimped lead* number of zeros following.
09 ø10 mm 20 ø20 mm *Excluding ø20
*Only the lead cut

Explanation of part numbers (Taping)


1 2 3 4 5 6 7 8 9 10 11 12

E R Z V D
Product code Series Design No.

Code Taping / Packaging Element Lead Norminal varistor voltage


Code Code
A to D Radial taping(Po=12.7 mm) size configuration The first two digits are significant
E to H Radial taping(Po=15.0 mm) 5 ø5 mm D Straight lead figures and the third one denotes the
7 ø7 mm V Crimped lead number of zeros following.
9 ø10 mm
A ø10 mm
E ø14 mm

Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 23-Dec-21
49
D type / V series
Reference guide to standard products
Maximum
Applicable Varistor Maximum Clamping
peak current
Part No. standards voltage* allowable voltage voltage 8/20 μs
at 8/20 μs (A)
Type name Approvals (V) AC rms (V) DC (V) max.(V) lp (A) 1 time 2 times
ERZV05D180 V180 ◇ 40 1 250 125
ERZV07D180 V7180 ◇ 36 2.5 500 250
ERZV09D180 V9180 ◇ 18 36 5 1000 500
11 14
ERZV10D180 V10180 ◇ (16 to 20) 36 5 1000 500
ERZV14D180 V14180 ◇ 36 10 2000 1000
ERZV20D180 V20180 ◇ 36 20 3000 2000
ERZV05D220 V220 ◇ 48 1 250 125
ERZV07D220 V7220 ◇ 43 2.5 500 250
ERZV09D220 V9220 ◇ 22 43 5 1000 500
14 18
ERZV10D220 V10220 ◇ (20 to 24) 43 5 1000 500
ERZV14D220 V14220 ◇ 43 10 2000 1000
ERZV20D220 V20220 ◇ 43 20 3000 2000
ERZV05D270 V270 ◇ 60 1 250 125
ERZV07D270 V7270 ◇ 53 2.5 500 250
ERZV09D270 V9270 ◇ 27 53 5 1000 500
17 22
ERZV10D270 V10270 ◇ (24 to 30) 53 5 1000 500
ERZV14D270 V14270 ◇ 53 10 2000 1000
ERZV20D270 V20270 ◇ 53 20 3000 2000
ERZV05D330 V330 ◇ 73 1 250 125
ERZV07D330 V7330 ◇ 65 2.5 500 250
ERZV09D330 V9330 ◇ 33 65 5 1000 500
20 26
ERZV10D330 V10330 ◇ (30 to 36) 65 5 1000 500
ERZV14D330 V14330 ◇ 65 10 2000 1000
ERZV20D330 V20330 ◇ 65 20 3000 2000
ERZV05D390 V390 ◇ 86 1 250 125
ERZV07D390 V7390 ◇ 77 2.5 500 250
ERZV09D390 V9390 ◇ 39 77 5 1000 500
25 31
ERZV10D390 V10390 ◇ (35 to 43) 77 5 1000 500
ERZV14D390 V14390 ◇ 77 10 2000 1000
ERZV20D390 V20390 ◇ 77 20 3000 2000
ERZV05D470 V470 ◇ 104 1 250 125
ERZV07D470 V7470 ◇ 93 2.5 500 250
ERZV09D470 V9470 ◇ 47 93 5 1000 500
30
ERZV10D470 V10470 ◇ (42 to 52) 38 93 5 1000 500
ERZV14D470 V14470 ◇ 93 10 2000 1000
ERZV20D470 V20470 ◇ 93 20 3000 2000
ERZV05D560 V560 ◇ 123 1 250 125
ERZV07D560 V7560 ◇ 110 2.5 500 250
ERZV09D560 V9560 ◇ 56 110 5 1000 500
35 45
ERZV10D560 V10560 ◇ (50 to 62) 110 5 1000 500
ERZV14D560 V14560 ◇ 110 10 2000 1000
ERZV20D560 V20560 ◇ 110 20 3000 2000
ERZV05D680 V680 ◇ 150 1 250 125
ERZV07D680 V7680 ◇ 135 2.5 500 250
ERZV09D680 V9680 ◇ 68 135 5 1000 500
40 56
ERZV10D680 V10680 ◇ (61 to 75) 135 5 1000 500
ERZV14D680 V14680 ◇ 135 10 2000 1000
ERZV20D680 V20680 ◇ 135 20 3000 2000

*Measuring Current of Varistor Voltage 5 Series(ERZV05D □□□):0.1 mA,Others:1 mA


○: UL1449 (VZCA2/UL, VZCA8/C-UL),
☆:VDE (IEC61051-1, -2, -2-2), ★ : VDE (IEC60950-1 Annex.Q, IEC62368-1 G8.2 ), □ : CSA C22.2 No.269.5
◇: CQC (GB/T10193, GB/T10194), ◆ : CQC (GB4943.1, GB8898)
※Approval number (File No.) of safety regulations are subject to revision without notice. Ask factory for a copy of the latest file No.

Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 23-Dec-21
50
D type / V series
Reference guide to standard products
Maximum
Applicable Varistor Maximum Clamping
peak current
Part No. standards voltage* allowable voltage voltage 8/20 μs
at 8/20 μs (A)
Type name Approvals (V) AC rms (V) DC (V) max.(V) lp (A) 1 time 2 times
ERZV05D820 V820U ○☆◇ 145 5 800 600
ERZV07D820 V7820U ○☆◇ 135 10 1750 1250
ERZV09D820 V9820U ○☆◇ 82 135 25 3500 2500
50 65
ERZV10D820 V10820U ○☆◇ (74 to 90) 135 25 3500 2500
ERZV14D820 V14820U ○☆◇ 135 50 6000 5000
ERZV20D820 V20820U ○☆◇ 135 100 10000 7000
ERZV05D101 V101U ○☆◇ 175 5 800 600
ERZV07D101 V7101U ○☆◇ 165 10 1750 1250
ERZV09D101 V9101U ○☆◇ 100 165 25 3500 2500
60 85
ERZV10D101 V10101U ○☆◇ (90 to 110) 165 25 3500 2500
ERZV14D101 V14101U ○☆◇ 165 50 6000 5000
ERZV20D101 V20101U ○☆◇ 165 100 10000 7000
ERZV05D121 V121U ○☆◇ 210 5 800 600
ERZV07D121 V7121U ○☆◇ 200 10 1750 1250
ERZV09D121 V9121U ○☆◇ 120 200 25 3500 2500
75 100
ERZV10D121 V10121U ○☆◇ (108 to 132) 200 25 3500 2500
ERZV14D121 V14121U ○☆◇ 200 50 6000 5000
ERZV20D121 V20121U ○☆◇ 200 100 10000 7000
ERZV05D151 V151U ○☆◇ 260 5 800 600
ERZV07D151 V7151U ○☆◇ 250 10 1750 1250
ERZV09D151 V9151U ○☆◇ 150 250 25 3500 2500
95 125
ERZV10D151 V10151U ○☆◇ (135 to 165) 250 25 3500 2500
ERZV14D151 V14151U ○☆◇ 250 50 6000 5000
ERZV20D151 V20151U ○☆◇ 250 100 10000 7000
ERZV05D201 V201U ○☆□◇ 355 5 800 600
ERZV07D201 V7201U ○☆□◇ 340 10 1750 1250
ERZV09D201 V9201U ○☆□◇ 200 340 25 3500 2500
130 170
ERZV10D201 V10201U ○☆□◇ (185 to 225) 340 25 3500 2500
ERZV14D201 V14201U ○☆★□◇◆ 340 50 6000 5000
ERZV20D201 V20201U ○☆★□◇◆ 340 100 10000 7000
ERZV05D221 V221U ○☆□◇ 380 5 800 600
ERZV07D221 V7221U ○☆□◇ 360 10 1750 1250
ERZV09D221 V9221U ○☆□◇ 220 360 25 3500 2500
140 180
ERZV10D221 V10221U ○☆□◇ (198 to 242) 360 25 3500 2500
ERZV14D221 V14221U ○☆★□◇◆ 360 50 6000 5000
ERZV20D221 V20221U ○☆★□◇◆ 360 100 10000 7000
ERZV05D241 V241U ○☆□◇ 415 5 800 600
ERZV07D241 V7241U ○☆□◇ 395 10 1750 1250
ERZV09D241 V9241U ○☆□◇ 240 395 25 3500 2500
150 200
ERZV10D241 V10241U ○☆□◇ (216 to 264) 395 25 3500 2500
ERZV14D241 V14241U ○☆★□◇◆ 395 50 6000 5000
ERZV20D241 V20241U ○☆★□◇◆ 395 100 10000 7000
ERZV05D271 V271U ○☆□◇ 475 5 800 600
ERZV07D271 V7271U ○☆□◇ 455 10 1750 1250
ERZV09D271 V9271U ○☆□◇ 270 455 25 3500 2500
175 225
ERZV10D271 V10271U ○☆□◇ (247 to 303) 455 25 3500 2500
ERZV14D271 V14271U ○☆★□◇◆ 455 50 6000 5000
ERZV20D271 V20271U ○☆★□◇◆ 455 100 10000 7000

*Measuring Current of Varistor Voltage 5 Series(ERZV05D □□□):0.1 mA,Others:1 mA


○: UL1449 (VZCA2/UL, VZCA8/C-UL),
☆:VDE (IEC61051-1, -2, -2-2), ★ : VDE (IEC60950-1 Annex.Q, IEC62368-1 G8.2 ), □ : CSA C22.2 No.269.5
◇: CQC (GB/T10193, GB/T10194), ◆ : CQC (GB4943.1, GB8898)
※Approval number (File No.) of safety regulations are subject to revision without notice. Ask factory for a copy of the latest file No.

Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 23-Dec-21
51
D type / V series
Reference guide to standard products
Maximum
Applicable Varistor Maximum Clamping
peak current
Part No. standards voltage* allowable voltage voltage 8/20 μs
at 8/20 μs (A)
Type name Approvals (V) AC rms (V) DC (V) max.(V) lp (A) 1 time 2 times
ERZV05D331 V331U ○☆□◇ 570 5 800 600
ERZV07D331 V7331U ○☆□◇ 545 10 1750 1250
ERZV09D331 V9331U ○☆□◇ 545 25 3500 2500
330 210 270
ERZV10D331 V10331U ○☆□◇ (297 to 363) 545 25 3500 2500
ERZV14D331 V14331U ○☆★□◇◆ 545 50 6000 4500
ERZV20D331 V20331U ○☆★□◇◆ 545 100 10000 6500
ERZV05D361 V361U ○☆□◇ 620 5 800 600
ERZV07D361 V7361U ○☆□◇ 595 10 1750 1250
ERZV09D361 V9361U ○☆□◇ 360 595 25 3500 2500
230 300
ERZV10D361 V10361U ○☆□◇ (324 to 396) 595 25 3500 2500
ERZV14D361 V14361U ○☆★□◇◆ 595 50 6000 4500
ERZV20D361 V20361U ○☆★□◇◆ 595 100 10000 6500
ERZV05D391 V391U ○☆□◇ 675 5 800 600
ERZV07D391 V7391U ○☆□◇ 650 10 1750 1250
ERZV09D391 V9391U ○☆□◇ 390 650 25 3500 2500
250 320
ERZV10D391 V10391U ○☆□◇ (351 to 429) 650 25 3500 2500
ERZV14D391 V14391U ○☆★□◇◆ 650 50 6000 4500
ERZV20D391 V20391U ○☆★□◇◆ 650 100 10000 6500
ERZV05D431 V431U ○☆□◇ 745 5 800 600
ERZV07D431 V7431U ○☆□◇ 710 10 1750 1250
ERZV09D431 V9431U ○☆□◇ 430 710 25 3500 2500
275 350
ERZV10D431 V10431U ○☆□◇ (387 to 473) 710 25 3500 2500
ERZV14D431 V14431U ○☆★□◇◆ 710 50 6000 4500
ERZV20D431 V20431U ○☆★□◇◆ 710 100 10000 6500
ERZV05D471 V471U ○☆□◇ 810 5 800 600
ERZV07D471 V7471U ○☆□◇ 775 10 1750 1250
ERZV09D471 V9471U ○☆□◇ 470 775 25 3500 2500
300 385
ERZV10D471 V10471U ○☆★□◇◆ (423 to 517) 775 25 3500 2500
ERZV14D471 V14471U ○☆★□◇◆ 775 50 6000 4500
ERZV20D471 V20471U ○☆★□◇◆ 775 100 10000 6500
ERZV07D511 V7511U ○☆□◇ 845 10 1750 1250
ERZV09D511 V9511U ○☆□◇ 845 25 3500 2500
510
ERZV10D511 V10511U ○☆★□◇◆ 320 410 845 25 3500 2500
(459 to 561)
ERZV14D511 V14511U ○☆★□◇◆ 845 50 6000 4500
ERZV20D511 V20511U ○☆★□◇◆ 845 100 10000 6500
ERZV10D561 V10561U ○☆★□◇◆ 930 25 3500 2500
560
ERZV14D561 V14561U ○☆★□◇◆ 350 450 930 50 5000 4500
(504 to 616)
ERZV20D561 V20561U ○☆★□◇◆ 930 100 7500 6500
ERZV10D621 V10621U ○☆★□◇◆ 1025 25 3500 2500
620
ERZV14D621 V14621U ○☆★□◇◆ 385 505 1025 50 5000 4500
(558 to 682)
ERZV20D621 V20621U ○☆★□◇◆ 1025 100 7500 6500
ERZV10D681 V10681U ○☆★□◇◆ 1120 25 3500 2500
680
ERZV14D681 V14681U ○☆★□◇◆ 420 560 1120 50 5000 4500
(612 to 748)
ERZV20D681 V20681U ○☆★□◇◆ 1120 100 7500 6500

*Measuring Current of Varistor Voltage 5 Series(ERZV05D □□□):0.1 mA,Others:1 mA


○: UL1449 (VZCA2/UL, VZCA8/C-UL),
☆:VDE (IEC61051-1, -2, -2-2), ★ : VDE (IEC60950-1 Annex.Q, IEC62368-1 G8.2 ), □ : CSA C22.2 No.269.5
◇: CQC (GB/T10193, GB/T10194), ◆ : CQC (GB4943.1, GB8898)
※Approval number (File No.) of safety regulations are subject to revision without notice. Ask factory for a copy of the latest file No.

Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 23-Dec-21
52
D type / V series
Reference guide to standard products
Maximum
Applicable Varistor Maximum Clamping
peak current
Part No. standards voltage* allowable voltage voltage 8/20 μs
at 8/20 μs (A)
Type name Approvals (V) AC rms (V) DC (V) max.(V) lp (A) 1 time 2 times
ERZV10D751 V10751U ○☆★□◇◆ 1240 25 3500 2500
750
ERZV14D751 V14751U ○☆★□◇◆ 460 615 1240 50 5000 4500
(675 to 825)
ERZV20D751 V20751U ○☆★□◇◆ 1240 100 7500 6500
ERZV10D821 V10821U ○☆★□◇◆ 1355 25 3500 2500
820
ERZV14D821 V14821U ○☆★□◇◆ 510 670 1355 50 5000 4500
(738 to 902)
ERZV20D821 V20821U ○☆★□◇◆ 1355 100 7500 6500
ERZV10D911 V10911U ○☆★□◇◆ 1500 25 3500 2500
910
ERZV14D911 V14911U ○☆★□◇◆ 550 745 1500 50 5000 4500
(819 to 1001)
ERZV20D911 V20911U ○☆★□◇◆ 1500 100 7500 6500
ERZV10D102 V10102U ○☆★□◇◆ 1650 25 3500 2500
1000
ERZV14D102 V14102U ○☆★□◇◆ 625 825 1650 50 5000 4500
(900 to 1100)
ERZV20D102 V20102U ○☆★□◇◆ 1650 100 7500 6500
ERZV10D112 V10112U ○☆★□◇◆ 1815 25 3500 2500
1100
ERZV14D112 V14112U ○☆★□◇◆ 680 895 1815 50 5000 4500
(990 to 1210)
ERZV20D112 V20112U ○☆★□◇◆ 1815 100 7500 6500
ERZV10D182CS V10182U ○☆★□◇◆ 2970 25 3500 2500
1800
ERZV14D182CS V14182U ○☆★□◇◆ 1000 1465 2970 50 5000 4500
(1700 to 1980)
ERZV20D182 V20182U ○☆★□◇◆ 2970 100 7500 6500

*Measuring Current of Varistor Voltage 5 Series(ERZV05D □□□):0.1 mA,Others:1 mA


○: UL1449 (VZCA2/UL, VZCA8/C-UL),
☆:VDE (IEC61051-1, -2, -2-2), ★ : VDE (IEC60950-1 Annex.Q, IEC62368-1 G8.2 ), □ : CSA C22.2 No.269.5
◇: CQC (GB/T10193, GB/T10194), ◆ : CQC (GB4943.1, GB8898)
※Approval number (File No.) of safety regulations are subject to revision without notice. Ask factory for a copy of the latest file No.

Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 23-Dec-21
53
D type / V5 series
Ratings and characteristics
●Operating temperature range : ‒40 to 85 ℃ ●Storage temperature range : ‒40 to 125 ℃
Clamping
Varistor Maximum Capacitance
Maximum voltage Rated
voltage Maximum energy peak current (max.)
allowable voltage (max.) power
Part No. at 0.1 mA (8/20 μs) at 1 kHz
**lp
AC rms DC (10/1000 μs) (2 ms) 1 time 2 times
(V) (V) (W) (pF)
(V) (V) (J) (J) (A) (A)
ERZV05D180 18(16 to 20) 11 14 40 0.01 0.6 0.4 250 125 1600
ERZV05D220 22(20 to 24) 14 18 48 0.01 0.7 0.5 250 125 1500
ERZV05D270 27(24 to 30) 17 22 60 0.01 0.9 0.7 250 125 1450
ERZV05D330 33(30 to 36) 20 26 73 0.01 1.1 0.8 250 125 1400
ERZV05D390 39(35 to 43) 25 31 86 0.01 1.2 0.9 250 125 700
ERZV05D470 47(42 to 52) 30 38 104 0.01 1.5 1.1 250 125 650
ERZV05D560 56(50 to 62) 35 45 123 0.01 1.8 1.3 250 125 600
ERZV05D680 68(61 to 75) 40 56 150 0.01 2.2 1.6 250 125 580
ERZV05D820 82(74 to 90) 50 65 145 0.1 3.5 2.5 800 600 460
ERZV05D101 100(90 to 110) 60 85 175 0.1 4.0 3.0 800 600 400
ERZV05D121 120(108 to 132) 75 100 210 0.1 5.0 3.5 800 600 350
ERZV05D151 150(135 to 165) 95 125 260 0.1 6.5 4.5 800 600 300

★The following part numbers, kindly also consider corresponding, smaller E Series devices with better performance for their size. → Please click here
ERZV05D201 200(185 to 225) 130 170 355 0.1 8.5 6.0 800 600 120
ERZV05D221 220(198 to 242) 140 180 380 0.1 9.0 6.5 800 600 110
ERZV05D241 240(216 to 264) 150 200 415 0.1 10.5 7.5 800 600 100
ERZV05D271 270(247 to 303) 175 225 475 0.1 11.0 8.0 800 600 90✽
ERZV05D331 330(297 to 363) 210 270 570 0.1 13.0 9.5 800 600 80✽
ERZV05D361 360(324 to 396) 230 300 620 0.1 16.0 11.0 800 600 80✽
ERZV05D391 390(351 to 429) 250 320 675 0.1 17.0 12.0 800 600 80✽
ERZV05D431 430(387 to 473) 275 350 745 0.1 20.0 13.5 800 600 70✽
ERZV05D471 470(423 to 517) 300 385 810 0.1 21.0 15.0 800 600 60✽
✽Measured at 1 MHz ✽✽Ip Measuring current of clamping voltage 180 to 680 : 1 A, 820 to 471 : 5 A

Dimensions in mm (not to scale)


Unit : mm
Part No. D max. T max. W±1.0 H max. L±1.0
ERZV05D180 7.0 4.5 5.0 10.0 1.5
ERZV05D220 7.0 4.5 5.0 10.0 1.5
ERZV05D270 7.0 4.5 5.0 10.0 1.5
ERZV05D330 7.0 4.5 5.0 10.0 1.5
ERZV05D390 7.0 4.5 5.0 10.0 1.5
ERZV05D470 7.0 4.5 5.0 10.0 1.5
ERZV05D560 7.0 4.5 5.0 10.0 1.5
ERZV05D680 7.0 4.5 5.0 10.0 1.5 D
T
ERZV05D820 7.0 4.1 5.0 10.0 1.4
ERZV05D101 7.0 4.3 5.0 10.0 1.6
H

ERZV05D121 7.0 4.5 5.0 10.0 1.8


ERZV05D151 7.0 4.8 5.0 10.0 2.1
L
★The following part numbers, kindly also consider corresponding, smaller E Series devices
20.0 min.

with better performance for their size. → Please click here


ERZV05D201 7.0 4.4 5.0 10.0 1.7 W

ERZV05D221 7.0 4.5 5.0 10.0 1.8


ø0.6 W
ERZV05D241 7.0 4.6 5.0 10.0 1.9
ERZV05D271 7.0 4.8 5.0 10.0 2.1
ERZV05D331 7.0 5.1 5.0 10.0 2.4
ERZV05D361 7.0 5.3 5.0 10.0 2.5
ERZV05D391 7.0 5.4 5.0 10.0 2.7
ERZV05D431 7.0 5.6 5.0 10.0 2.9
ERZV05D471 7.0 5.8 5.0 10.0 3.1

Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 23-Dec-21

54
D type / V5 series
Typical characteristics
Voltage vs. Current Impulse Derating (Relation between
impulse width and impulse current multiple)

ERZV05D180 to ERZV05D680 ERZV05D180 to ERZV05D680


Max.Leakage 1000
Current Max.Clamping Voltage
400 2 times:5 min. interval
680 up to 10 times:2 min. interval
300 up to 106 times : 10 sec. interval
560
470
200 390
330

270 100
390
100 220
90
80 180
70
60

Impulse current (A)


50
Voltage (V)

40

30 10

20

10
9 1
8
7
6

5
Test current waveform
10–6 to 10–4 A: Direct current
4 10–1 to 103 A: 8/20 μs

3
10-6 10-5 10-4 10-3 10-2 10-1 100 101 102 103 104 105 0.1
20 100 1000 10000
Current (A)
Impulse width (μs)

ERZV05D820 to ERZV05D471 ERZV05D820 to ERZV05D471


1000
Max.Leakage Max.Clamping Voltage
Current 2 times:5 min. interval
2000 up to 10 times:2 min. interval
up to 106 times : 10 sec. interval

471
431 431
391 391
1000 361 361
331
900
271 100
800
241
700 221
600 201

500
Impulse current (A)

151
400
Voltage (V)

121

300 101
10
820
200

100
90 1
80
70
60
50 Test current waveform
331 10–6 to 10–4 A: Direct current
10–1 to 103 A: 8/20 μs
40 221

30
10-6 10-5 10-4 10-3 10-2 10-1 100 101 102 103 104 105 0.1
20 100 1000 10000
Current (A) Impulse width (μs)

Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 23-Dec-21
55
D type / V7 series
Ratings and characteristics
●Operating temperature range : ‒40 to 85 ℃ ●Storage temperature range : ‒40 to 125 ℃
Clamping
Varistor Maximum Capacitance
Maximum voltage Rated
voltage Maximum energy peak current (max.)
allowable voltage (max.) power
Part No. at 1 mA (8/20 μs) at 1 kHz
**lp
AC rms DC (10/1000 μs) (2 ms) 1 time 2 times
(V) (V) (W) (pF)
(V) (V) (J) (J) (A) (A)
ERZV07D180 18(16 to 20) 11 14 36 0.02 1.1 0.9 500 250 3800
ERZV07D220 22(20 to 24) 14 18 43 0.02 1.3 1.1 500 250 3600
ERZV07D270 27(24 to 30) 17 22 53 0.02 1.6 1.3 500 250 3400
ERZV07D330 33(30 to 36) 20 26 65 0.02 2.0 1.6 500 250 2900
ERZV07D390 39(35 to 43) 25 31 77 0.02 2.4 1.9 500 250 1600
ERZV07D470 47(42 to 52) 30 38 93 0.02 2.8 2.3 500 250 1550
ERZV07D560 56(50 to 62) 35 45 110 0.02 3.4 2.7 500 250 1500
ERZV07D680 68(61 to 75) 40 56 135 0.02 4.1 3.3 500 250 1200
ERZV07D820 82(74 to 90) 50 65 135 0.25 7 5 1750 1250 810
ERZV07D101 100(90 to 110) 60 85 165 0.25 8.5 6 1750 1250 700
ERZV07D121 120(108 to 132) 75 100 200 0.25 10 7 1750 1250 590
ERZV07D151 150(135 to 165) 95 125 250 0.25 13 9 1750 1250 500

★The following part numbers, kindly also consider corresponding, smaller E Series devices with better performance for their size. → Please click here
ERZV07D201 200(185 to 225) 130 170 340 0.25 17.5 12.5 1750 1250 200
ERZV07D221 220(198 to 242) 140 180 360 0.25 19 13.5 1750 1250 190
ERZV07D241 240(216 to 264) 150 200 395 0.25 21 15 1750 1250 170
ERZV07D271 270(247 to 303) 175 225 455 0.25 24 17 1750 1250 150
ERZV07D331 330(297 to 363) 210 270 545 0.25 28 20 1750 1250 130
ERZV07D361 360(324 to 396) 230 300 595 0.25 32 23 1750 1250 130
ERZV07D391 390(351 to 429) 250 320 650 0.25 35 25 1750 1250 130
ERZV07D431 430(387 to 473) 275 350 710 0.25 40 27.5 1750 1250 120
ERZV07D471 470(423 to 517) 300 385 775 0.25 42 30 1750 1250 100
ERZV07D511 510(459 to 561) 320 410 845 0.25 45 32 1750 1250 90✽
✽Measured at 1 MHz ✽✽Ip Measuring current of clamping voltage 180 to 680 : 2.5 A, 820 to 511 : 10 A

Dimensions in mm (not to scale)


Unit : mm
Part No. D max. T max. W±1.0 H max. L±1.0
ERZV07D180 8.5 4.5 5.0 11.5 1.3
ERZV07D220 8.5 4.6 5.0 11.5 1.4
ERZV07D270 8.5 4.7 5.0 11.5 1.5
ERZV07D330 8.5 4.9 5.0 11.5 1.7
ERZV07D390 8.5 4.8 5.0 11.5 1.6
ERZV07D470 8.5 4.9 5.0 11.5 1.7
ERZV07D560 8.5 5.0 5.0 11.5 1.8
D
ERZV07D680 8.5 5.2 5.0 11.5 2.0 T
ERZV07D820 8.5 4.1 5.0 11.5 1.4
ERZV07D101 8.5 4.3 5.0 11.5 1.6
H

ERZV07D121 8.5 4.5 5.0 11.5 1.8


ERZV07D151 8.5 4.8 5.0 11.5 2.1
L
★The following part numbers, kindly also consider corresponding, smaller E Series devices
20.0 min.

with better performance for their size. → Please click here


L

ERZV07D201 8.5 4.4 5.0 11.5 1.7 W

ERZV07D221 8.5 4.5 5.0 11.5 1.8


ø0.6 W
ERZV07D241 8.5 4.6 5.0 11.5 1.9
ERZV07D271 8.5 4.8 5.0 11.5 2.1
ERZV07D331 8.5 5.1 5.0 11.5 2.4
ERZV07D361 8.5 5.3 5.0 11.5 2.5
ERZV07D391 8.5 5.4 5.0 11.5 2.7
ERZV07D431 8.5 5.6 5.0 11.5 2.9
ERZV07D471 8.5 5.8 5.0 11.5 3.1
ERZV07D511 8.5 6.0 5.0 11.5 3.3

Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 23-Dec-21
56
D type / V7 series
Typical characteristics
Voltage vs. Current Impulse Derating (Relation between
impulse width and impulse current multiple)

ERZV07D180 to ERZV07D680 ERZV07D180 to ERZV07D680


1000

Max.Leakage Max.Clamping Voltage 2 times:5 min. interval


400 Current
680 up to 10 times:2 min. interval
300 560
up to 106 times : 10 sec. interval

470
200 390
330
270 100
220
100
90 180
80

Impulse current (A)


70
60
Voltage (V)

50

40
10

30

20

10 1
9
8
7
6

5
Test current waveform
4 10–6 to 10–3 A: Direct current
10–1 to 103 A: 8/20 μs
3 0.1
10-6 10-5 10-4 10-3 10-2 10-1 100 101 102 103 104 105 20 100 1000 10000
Impulse width (μs)
Current (A)

ERZV07D820 to ERZV07D511 ERZV07D820 to ERZV07D511


10000
2 times:5 min. interval
2000 Max.Leakage Max.Clamping Voltage up to 10 times:2 min. interval
Current
511 up to 106 times : 10 sec. interval
471
431
391
471 361
431
1000 391 331
900 361 271 1000
800 241
700 221
600 201
Impulse current (A)

500 151
Voltage (V)

400 121

300 101 100

820

200

100
90 10
80
70
60
50 Test current waveform
10–6 to 10–3 A: Direct current
10–1 to 104 A: 8/20 μs
331
40
321
30 1
10-6 10-5 10-4 10-3 10-2 10-1 100 101 102 103 104 105 20 100 1000 10000
Current (A)
Impulse width (μs)

Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 23-Dec-21
57
D type / V9 series
Ratings and characteristics
●Operating temperature range : ‒40 to 85 ℃ ●Storage temperature range : ‒40 to 125 ℃
Clamping
Varistor Maximum Capacitance
Maximum voltage Rated
voltage Maximum energy peak current (max.)
allowable voltage (max.) power
Part No. at 1 mA (8/20 μs) at 1 kHz
**lp
AC rms DC (10/1000 μs) (2 ms) 1 time 2 times
(V) (V) (W) (pF)
(V) (V) (J) (J) (A) (A)
ERZV09D180 18(16 to 20) 11 14 36 0.05 2.6 2.2 1000 500 16000
ERZV09D220 22(20 to 24) 14 18 43 0.05 3.2 2.6 1000 500 11000
ERZV09D270 27(24 to 30) 17 22 53 0.05 3.9 3.2 1000 500 8000
ERZV09D330 33(30 to 36) 20 26 65 0.05 4.8 4.0 1000 500 6300
ERZV09D390 39(35 to 43) 25 31 77 0.05 5.6 4.7 1000 500 5200
ERZV09D470 47(42 to 52) 30 38 93 0.05 6.8 5.6 1000 500 4600
ERZV09D560 56(50 to 62) 35 45 110 0.05 8.1 6.7 1000 500 3750
ERZV09D680 68(61 to 75) 40 56 135 0.05 9.8 8.2 1000 500 2800
ERZV09D820 82(74 to 90) 50 65 135 0.4 14.0 10 3500 2500 2000
ERZV09D101 100(90 to 110) 60 85 165 0.4 17 12 3500 2500 1700
ERZV09D121 120(108 to132) 75 100 200 0.4 20 14.5 3500 2500 1400
ERZV09D151 150(135 to 165) 95 125 250 0.4 25 18 3500 2500 1100

★The following part numbers, kindly also consider corresponding, smaller E Series devices with better performance for their size. → Please click here
ERZV09D201 200(185 to 225) 130 170 340 0.4 35 25 3500 2500 430
ERZV09D221 220(198 to 242) 140 180 360 0.4 39 27.5 3500 2500 410
ERZV09D241 240(216 to264) 150 200 395 0.4 42 30 3500 2500 380
ERZV09D271 270(247 to 303) 175 225 455 0.4 49 35 3500 2500 350
ERZV09D331 330(297 to 363) 210 270 545 0.4 58 42 3500 2500 300
ERZV09D361 360(324 to 396) 230 300 595 0.4 65 45 3500 2500 300
ERZV09D391 390(351 to 429) 250 320 650 0.4 70 50 3500 2500 300
ERZV09D431 430(387 to 473) 275 350 710 0.4 80 55 3500 2500 270
ERZV09D471 470(423 to 517) 300 385 775 0.4 85 60 3500 2500 230
ERZV09D511 510(459 to 561) 320 410 845 0.4 92 67 3500 2500 210
✽Ip Measuring current of clamping voltage 180 to 680 : 5 A, 820 to 511 : 25 A

Dimensions in mm (not to scale)


Unit : mm
Part No. D max. T max. W±1.0 H max. L±1.0
ERZV09D180 11.5 3.8 5.0 14.0 1.3
ERZV09D220 11.5 4.0 5.0 14.0 1.4
ERZV09D270 11.5 4.2 5.0 14.0 1.5
ERZV09D330 11.5 4.5 5.0 14.0 1.7
ERZV09D390 11.5 4.0 5.0 14.0 1.7
ERZV09D470 11.5 4.2 5.0 14.0 1.8
ERZV09D560 11.5 4.4 5.0 14.0 1.9 D
T
ERZV09D680 11.5 4.5 5.0 14.0 2.2
ERZV09D820 11.5 3.8 5.0 14.0 1.6
ERZV09D101 11.5 3.9 5.0 14.0 1.8
H

ERZV09D121 11.5 4.1 5.0 14.0 2.0


ERZV09D151 11.5 4.4 5.0 14.0 2.2 L
20.0 min.

★The following part numbers, kindly also consider corresponding, smaller E Series devices
L

with better performance for their size. → Please click here W


ERZV09D201 11.5 4.1 5.0 14.0 1.7
ERZV09D221 11.5 4.2 5.0 14.0 1.8 ø0.6 W
ERZV09D241 11.5 4.3 5.0 14.0 1.9
ERZV09D271 11.5 4.5 5.0 14.0 2.0
ERZV09D331 11.5 4.8 5.0 14.0 2.3
ERZV09D361 11.5 5.0 5.0 14.0 2.5
ERZV09D391 11.5 5.1 5.0 14.0 2.6
ERZV09D431 11.5 5.3 5.0 14.0 2.8
ERZV09D471 11.5 5.6 5.0 14.0 3.1
ERZV09D511 11.5 5.8 5.0 14.0 3.2

Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 23-Dec-21

58
D type / V9 series
Typical characteristics
Voltage vs. Current Impulse Derating (Relation between
impulse width and impulse current multiple)

ERZV09D180 to ERZV09D680 ERZV09D180 to ERZV09D680


1000
Max.Leakage Max.Clamping Voltage 680
Current 2 times:5 min. interval
400 560 up to 10 times:2 min. interval
up to 106 times : 10 sec. interval
300 470
390
200 330

270
220 100
180
100
90
80
70

Impulse current (A)


60
50
Voltage (V)

40
10

30

20

10 1
9
8
7
6

5
Test current waveform
4 10–6 to 10–3 A: Direct current
10–1 to 103 A: 8/20 μs
3 0.1
10-6 10-5 10-4 10-3 10-2 10-1 100 101 102 103 104 105 20 100 1000 10000

Current (A) Impulse width (μs)

ERZV09D820 to ERZV09D511 ERZV09D820 to ERZV09D511


10000

2 times:5 min. interval


Max.Leakage Max.Clamping Voltage up to 10 times:2 min. interval
Current
2000 511 up to 106 times : 10 sec. interval
471
431
391
361
471 331
1000 271
431 1000
900 241
391
800 221
361
700 201
600
Impulse current (A)

500 151

400 121
Voltage (V)

101
300 100
820

200

100
90 10
80
70
60
50
Test current waveform
40 331 10–6 to 10–3 A: Direct current
10–1 to 104 A: 8/20 μs
321
30 1
10-6 10-5 10-4 10-3 10-2 10-1 100 101 102 103 104 105 20 100 1000 10000
Current (A) Impulse width (μs)

Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 23-Dec-21
59
D type / V10 series
Ratings and characteristics
●Operating temperature range : ‒40 to 85 ℃ ●Storage temperature range : ‒40 to 125 ℃
Clamping
Varistor Maximum Capacitance
Maximum voltage Rated
voltage Maximum energy peak current (max.)
allowable voltage (max.) power
Part No. at 1 mA (8/20 μs) at 1 kHz
**lp
AC rms DC (10/1000 μs) (2 ms) 1 time 2 times
(V) (V) (W) (pF)
(V) (V) (J) (J) (A) (A)
ERZV10D180 18(16 to 20) 11 14 36 0.05 2.6 2.2 1000 500 16000
ERZV10D220 22(20 to 24) 14 18 43 0.05 3.2 2.6 1000 500 11000
ERZV10D270 27(24 to 30) 17 22 53 0.05 3.9 3.2 1000 500 8000
ERZV10D330 33(30 to 36) 20 26 65 0.05 4.8 4.0 1000 500 6300
ERZV10D390 39(35 to 43) 25 31 77 0.05 5.6 4.7 1000 500 5200
ERZV10D470 47(42 to 52) 30 38 93 0.05 6.8 5.6 1000 500 4600
ERZV10D560 56(50 to 62) 35 45 110 0.05 8.1 6.7 1000 500 3750
ERZV10D680 68(61 to 75) 40 56 135 0.05 9.8 8.2 1000 500 2800
ERZV10D820 82(74 to 90) 50 65 135 0.4 14 10 3500 2500 2000
ERZV10D101 100(90 to 110) 60 85 165 0.4 17 12 3500 2500 1700
ERZV10D121 120(108 to 132) 75 100 200 0.4 20 14.5 3500 2500 1400
ERZV10D151 150(135 to 165) 95 125 250 0.4 25 18 3500 2500 1100

★The following part numbers, kindly also consider corresponding, smaller E Series devices with better performance for their size. → Please click here
ERZV10D201 200(185 to 225) 130 170 340 0.4 35 25 3500 2500 430
ERZV10D221 220(198 to 242) 140 180 360 0.4 39 27.5 3500 2500 410
ERZV10D241 240(216 to 264) 150 200 395 0.4 42 30 3500 2500 380
ERZV10D271 270(247 to 303) 175 225 455 0.4 49 35 3500 2500 350
ERZV10D331 330(297 to 363) 210 270 545 0.4 58 42 3500 2500 300
ERZV10D361 360(324 to 396) 230 300 595 0.4 65 45 3500 2500 300
ERZV10D391 390(351 to 429) 250 320 650 0.4 70 50 3500 2500 300
ERZV10D431 430(387 to 473) 275 350 710 0.4 80 55 3500 2500 270
ERZV10D471 470(423 to 517) 300 385 775 0.4 85 60 3500 2500 230
ERZV10D511 510(459 to 561) 320 410 845 0.4 92 67 3500 2500 210
ERZV10D561 560(504 to 616) 350 450 930 0.4 92 67 3500 2500 200
ERZV10D621 620(558 to 682) 385 505 1025 0.4 92 67 3500 2500 190
ERZV10D681 680(612 to 748) 420 560 1120 0.4 92 67 3500 2500 170
ERZV10D751 750(675 to 825) 460 615 1240 0.4 100 70 3500 2500 160
ERZV10D821 820(738 to 902) 510 670 1355 0.4 110 80 3500 2500 140
ERZV10D911 910(819 to 1001) 550 745 1500 0.4 130 90 3500 2500 120
ERZV10D102 1000(900 to 1100) 625 825 1650 0.4 140 100 3500 2500 110
ERZV10D112 1100(990 to 1210) 680 895 1815 0.4 155 110 3500 2500 110

ERZV10D182CS 1800(1700 to 1980) 1000 1465 2970 0.4* 247 183*** 3500 2500 ***70✽

✽Measured at 1 MHz ✽✽Ip Measuring current of clamping voltage 180 to 680 : 5 A, 820 to 182 : 25 A

Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 23-Dec-21
60
D type / V10 series
Dimensions in mm (not to scale)
Unit : mm
Part No. D max. T max. W±1.0 H max. L±1.0
ERZV10D180 11.5 4.6 7.5 14.5 1.3
ERZV10D220 11.5 4.7 7.5 14.5 1.4
ERZV10D270 11.5 4.8 7.5 14.5 1.5 D
ERZV10D330 11.5 5.0 7.5 14.5 1.7 T
ERZV10D390 11.5 4.9 7.5 14.5 1.6
ERZV10D470 11.5 5.0 7.5 14.5 1.7
ERZV10D560 11.5 5.1 7.5 14.5 1.8

H
ERZV10D680 11.5 5.3 7.5 14.5 2.0
ERZV10D820 11.5 4.5 7.5 14.5 1.6
L
ERZV10D101 11.5 4.7 7.5 14.5 1.8
ERZV10D121 11.5 4.9 7.5 14.5 2.0

20.0 min.

L
ERZV10D151 11.5 5.2 7.5 14.5 2.3
W
★The following part numbers, kindly also consider corresponding, smaller E Series devices
with better performance for their size. → Please click here ø0.8 W
ERZV10D201 11.5 4.8 7.5 14.5 1.9
ERZV10D221 11.5 4.9 7.5 14.5 2.0
ERZV10D241 11.5 5.0 7.5 14.5 2.1
ERZV10D271 11.5 5.2 7.5 14.5 2.3
ERZV10D331 11.5 5.5 7.5 14.5 2.6
ERZV10D361 11.5 5.7 7.5 14.5 2.8 (ERZV10D182CS)
ERZV10D391 11.5 5.8 7.5 14.5 2.9
ERZV10D431 11.5 6.0 7.5 14.5 3.1 D
T
ERZV10D471 11.5 6.2 7.5 14.5 3.3
ERZV10D511 11.5 6.4 7.5 14.5 3.5
ERZV10D561 12.5 6.7 7.5 15.5 3.8

L
ERZV10D621 12.5 7.1 7.5 15.5 4.2

H
ERZV10D681 12.5 7.4 7.5 15.5 4.5
ERZV10D751 12.5 7.8 7.5 15.5 4.9

4.0±1.5
ERZV10D821 12.5 8.1 7.5 15.5 5.2 L
ERZV10D911 12.5 8.6 7.5 15.5 5.7 ø0.8
ERZV10D102 12.5 9.1 7.5 15.5 6.2
ERZV10D112 12.5 9.7 7.5 15.5 6.8
ERZV10D182CS 13.5 14.4 11.0✽ 16.5 10.0 (±1.5)
✽ W2
Typical characteristics
Voltage vs. Current Impulse Derating (Relation between
impulse width and impulse current multiple)

ERZV10D180 to ERZV10D680 ERZV10D180 to ERZV10D680


Max.Leakage Max.Clamping Voltage 680 1000
400 Current
560
2 times:5 min. interval
300 470 up to 10 times:2 min. interval
390 up to 106 times:10 sec. interval

200 330
270 100

220
Impulse current (A)

100 180
90
80
Voltage (V)

70 10
60
50
40

30
1

20

0.1
10 20 100 1000 10000
9
8 Impulse width (μs)
7
6
Test current waveform
5 10–6 to 10–3 A: Direct current
10–1 to 103 A: 8/20 μs
4

3
10-6 10-5 10-4 10-3 10-2 10-1 100 101 102 103 104 105
Current (A)
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 23-Dec-21
61
D type / V10 series
Typical characteristics
Voltage vs. Current Impulse Derating (Relation between
impulse width and impulse current multiple)

ERZV10D820 to ERZV10D511 ERZV10D820 to ERZV10D511


10000
2 times:5 min. interval
Max.Leakage Max.Clamping Voltage up to 10 times:2 min. interval
Current
up to 106 times : 10 sec. interval
2000 511
471
431 1000
391
361
1000 331
471
271
900 431

Impulse current (A)


241
800 391
221
361 100
700 201

600
500
151
400 10
Voltage (V)

121
101
300
820

200 1
20 100 1000 10000
Impulse width (μs)

100 ERZV10D561 to ERZV10D112


90
10000
80
70 2 times:5 min. interval
up to 10 times:2 min. interval
60 up to 106 times : 10 sec. interval
50
Test current waveform
10–6 to 10–3 A: Direct current 1000
Impulse current (A)
40 331 10–1 to 104 A: 8/20 μs
321
30
10-6 10-5 10-4 10-3 10-2 10-1 100 101 102 103 104 105

Current (A)
100
ERZV10D561 to ERZV10D182CS
5000

Max.Leakage Max.Clamping Voltage


Current 182CS
4000 10

3000 102
911 112
821 102
1
911
821 20 100 1000 10000
2000
751
681 Impulse width (μs)
621 ERZV10D182CS
561 10000
Voltage (V)

2 times:5 min. interval


up to 10 times:2 min. interval
up to 106 times : 10 sec. interval
1000
900
1000
800
Impulse current (A)

700

600
100
500

400

10
300 751 Test current waveform
681 10–6 to 10–3 A: Direct current
621 10–1 to 104 A: 8/20 μs

200 1
10-6 10-5 10-4 10-3 10-2 10-1 100 101 102 103 104 105
20 100 1000 10000
Current (A)
Impulse width (μs)

Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 23-Dec-21
62
D type / V14 series
Ratings and characteristics
●Operating temperature range : ‒40 to 85 ℃ ●Storage temperature range : ‒40 to 125 ℃
Clamping
Varistor Maximum Capacitance
Maximum voltage Rated
voltage Maximum energy peak current (max.)
allowable voltage (max.) power
Part No. at 1 mA (8/20 μs) at 1 kHz
**lp
AC rms DC (10/1000 μs) (2 ms) 1 time 2 times
(V) (V) (W) (pF)
(V) (V) (J) (J) (A) (A)
ERZV14D180 18(16 to 20) 11 14 36 0.1 5.2 4.3 2000 1000 25000
ERZV14D220 22(20 to 24) 14 18 43 0.1 6.3 5.3 2000 1000 20000
ERZV14D270 27(24 to 30) 17 22 53 0.1 7.8 6.5 2000 1000 16000
ERZV14D330 33(30 to 36) 20 26 65 0.1 9.5 7.9 2000 1000 12200
ERZV14D390 39(35 to 43) 25 31 77 0.1 11 9.4 2000 1000 7000
ERZV14D470 47(42 to 52) 30 38 93 0.1 14 11 2000 1000 6750
ERZV14D560 56(50 to 62) 35 45 110 0.1 16 13 2000 1000 6500
ERZV14D680 68(61 to 75) 40 56 135 0.1 20 16 2000 1000 5500
ERZV14D820 82(74 to 90) 50 65 135 0.6 28 20 6000 5000 3700
ERZV14D101 100(90 to 110) 60 85 165 0.6 35 25 6000 5000 3200
ERZV14D121 120(108 to 132) 75 100 200 0.6 42 30 6000 5000 2700
ERZV14D151 150(135 to 165) 95 125 250 0.6 53 37.5 6000 5000 2200

★The following part numbers, kindly also consider corresponding, smaller E Series devices with better performance for their size. → Please click here
ERZV14D201 200(185 to 225) 130 170 340 0.6 70 50 6000 5000 770
ERZV14D221 220(198 to 242) 140 180 360 0.6 78 55 6000 5000 740
ERZV14D241 240(216 to 264) 150 200 395 0.6 84 60 6000 5000 700
ERZV14D271 270(247 to 303) 175 225 455 0.6 99 70 6000 5000 640
ERZV14D331 330(297 to 363) 210 270 545 0.6 115 80 6000 4500 580
ERZV14D361 360(324 to 396) 230 300 595 0.6 130 90 6000 4500 540
ERZV14D391 390(351 to 429) 250 320 650 0.6 140 100 6000 4500 500
ERZV14D431 430(387 to 473) 275 350 710 0.6 155 110 6000 4500 450
ERZV14D471 470(423 to 517) 300 385 775 0.6 175 125 6000 4500 400
ERZV14D511 510(459 to 561) 320 410 845 0.6 190 136 6000 4500 350
ERZV14D561 560(504 to 616) 350 450 930 0.6 190 136 5000 4500 340
ERZV14D621 620(558 to 682) 385 505 1025 0.6 190 136 5000 4500 330
ERZV14D681 680(612 to 748) 420 560 1120 0.6 190 136 5000 4500 320
ERZV14D751 750(675 to 825) 460 615 1240 0.6 210 150 5000 4500 310
ERZV14D821 820(738 to 902) 510 670 1355 0.6 235 165 5000 4500 280
ERZV14D911 910(819 to 1001) 550 745 1500 0.6 255 180 5000 4500 250
ERZV14D102 1000(900 to 1100) 625 825 1650 0.6 280 200 5000 4500 230
ERZV14D112 1100(990 to 1210) 680 895 1815 0.6 310 220 5000 4500 210

ERZV14D182CS 1800(1700 to 1980) 1000 1465 2970 0.6 510 360 5000 4500 120
✽Ip Measuring current of clamping voltage 180 to 680 : 10 A, 820 to 182 : 50 A

Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 23-Dec-21
63
D type / V14 series
Dimensions in mm (not to scale)
Unit : mm
Part No. D max. T max. W±1.0 H max. L±1.0
ERZV14D180 15.5 4.6 7.5 18.5 1.3 D
T
ERZV14D220 15.5 4.7 7.5 18.5 1.4
ERZV14D270 15.5 4.8 7.5 18.5 1.5
ERZV14D330 15.5 5.0 7.5 18.5 1.7

H
ERZV14D390 15.5 4.9 7.5 18.5 1.6
ERZV14D470 15.5 5.0 7.5 18.5 1.7
ERZV14D560 15.5 5.1 7.5 18.5 1.8 L
ERZV14D680 15.5 5.3 7.5 18.5 2.0

20.0 min.
ERZV14D820 15.5 4.5 7.5 18.5 1.6

L
ERZV14D101 15.5 4.7 7.5 18.5 1.8 W
ERZV14D121 15.5 4.9 7.5 18.5 2.0
ERZV14D151 15.5 5.2 7.5 18.5 2.3 ø0.8 W
★The following part numbers, kindly also consider corresponding, smaller E Series devices
with better performance for their size. → Please click here
ERZV14D201 15.5 4.8 7.5 18.5 1.9
ERZV14D221 15.5 4.9 7.5 18.5 2.0
ERZV14D241 15.5 5.0 7.5 18.5 2.1
ERZV14D271 15.5 5.2 7.5 18.5 2.3
ERZV14D331 15.5 5.5 7.5 18.5 2.6 (ERZV14D182CS)
ERZV14D361 15.5 5.7 7.5 18.5 2.8
ERZV14D391 15.5 5.8 7.5 18.5 2.9 D
T
ERZV14D431 15.5 6.0 7.5 18.5 3.1
ERZV14D471 15.5 6.2 7.5 18.5 3.3
ERZV14D511 15.5 6.4 7.5 18.5 3.5
ERZV14D561 16.0 6.7 7.5 19.0 3.8

L
H
ERZV14D621 16.0 7.1 7.5 19.0 4.2
ERZV14D681 16.0 7.4 7.5 19.0 4.5

4.0±1.5
ERZV14D751 16.0 7.8 7.5 19.0 4.9 ø0.8 L
ERZV14D821 16.0 8.1 7.5 19.0 5.2
ERZV14D911 16.0 8.6 7.5 19.0 5.7
ERZV14D102 16.0 9.1 7.5 19.0 6.2
ERZV14D112 16.0 9.7 7.5 19.0 6.8

ERZV14D182CS 17.0 14.4* 15.0✽ 20.5 10.5 (±2.0)


✽:W 2

Typical characteristics
Voltage vs. Current Impulse Derating (Relation between
impulse width and impulse current multiple)
ERZV14D180 to ERZV14D680 ERZV14D180 to ERZV14D680

Max.Leakage Max.Clamping Voltage


Current 680
400 10000
560
2 times:5 min. interval
300 470 up to 10 times:2 min. interval
390 up to 106 times : 10 sec. interval
200 330
270 1000
220
470
100
180
90
Impulse current (A)

80
70
Voltage (V)

60 100
50
40

30
10
20

10 1
20 100 1000 10000
9
8
Impulse width (μs)
7
6
5 Test current waveform
10–6 to 10–3 A: Direct current
4 10–1 to 104 A: 8/20 μs

3
10-6 10-5 10-4 10-3 10-2 10-1 100 101 102 103 104 105

Current (A)

Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 23-Dec-21
64
D type / V14 series
Typical characteristics
Voltage vs. Current Impulse Derating (Relation between
impulse width and impulse current multiple)

ERZV14D820 to ERZV14D511 ERZV14D820 to ERZV14D511


10000
2 times:5 min. interval
Max.Leakage Max.Clamping Voltage
Current 511 up to 10 times:2 min. interval
2000 up to 106 times : 10 sec. interval
471
431
391
361 1000
471 331
431 271
1000 241
391
900 361 221

Impulse current (A)


800 201
700 100
600 151
121
500
Voltage (V)

400 101
820 10
300

200
1
20 100 1000 10000

Impulse width (μs)


100
90 ERZV14D561 to ERZV14D112
80 10000
70 2 times:5 min. interval
60 up to 10 times:2 min. interval
up to 106 times : 10 sec. interval
50

40 331 Test current waveform 1000


321 10–6 to 10–3 A: Direct current
30 10–1 to 104 A: 8/20 μs
10-6 10-5 10-4 10-3 10-2 10-1 100 101 102 103 104 105
Impulse current (A)

Current (A)
100

ERZV14D561 to ERZV14D182CS
5000

Max.Leakage Max.Clamping Voltage


Current 182CS 10
4000

102
3000 911
821 112
102 1
911
821 20 100 1000 10000
2000 Impulse width (μs)
751
681
621 ERZV14D182CS
561
10000
2 times:5 min. interval
Voltage (V)

up to 10 times:2 min. interval


up to 106 times : 10 sec. interval
1000
900 1000
Impulse current (A)

800

700

600
100
500

400

10
300
Test current waveform
751 10–6 to 10–3 A: Direct current
10–1 to 104 A: 8/20 μs
681
621
200 1

10-6 10-5 10-4 10-3 10-2 10-1 100 101 102 103 104 105 20 100 1000 10000
Current (A) Impulse width (μs)

Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 23-Dec-21
65
D type / V20 series
Ratings and characteristics
●Operating temperature range : ‒40 to 85 ℃ ●Storage temperature range : ‒40 to 125 ℃
Clamping
Varistor Maximum Capacitance
Maximum voltage Rated
voltage Maximum energy peak current (max.)
allowable voltage (max.) power
Part No. at 1 mA (8/20 μs) at 1 kHz
**lp
AC rms DC (10/1000 μs) (2 ms) 1 time 2 times
(V) (V) (W) (pF)
(V) (V) (J) (J) (A) (A)
ERZV20D180 18(16 to 20) 11 14 36 0.2 13 12 3000 2000 40000
ERZV20D220 22(20 to 24) 14 18 43 0.2 16 14 3000 2000 30000
ERZV20D270 27(24 to 30) 17 22 53 0.2 19 17 3000 2000 24500
ERZV20D330 33(30 to 36) 20 26 65 0.2 24 21 3000 2000 20000
ERZV20D390 39(35 to 43) 25 31 77 0.2 28 25 3000 2000 13800
ERZV20D470 47(42 to 52) 30 38 93 0.2 34 30 3000 2000 13500
ERZV20D560 56(50 to 62) 35 45 110 0.2 41 36 3000 2000 12200
ERZV20D680 68(61 to 75) 40 56 135 0.2 49 44 3000 2000 11500
ERZV20D820 82(74 to 90) 50 65 135 1.0 56 40 10000 7000 7500
ERZV20D101 100(90 to 110) 60 85 165 1.0 70 50 10000 7000 6500
ERZV20D121 120(108 to 132) 75 100 200 1.0 85 60 10000 7000 5500
ERZV20D151 150(135 to 165) 95 125 250 1.0 106 75 10000 7000 4500

★The following part numbers, kindly also consider corresponding, smaller E Series devices with better performance for their size. → Please click here
ERZV20D201 200(185 to 225) 130 170 340 1.0 140 100 10000 7000 1700
ERZV20D221 220(198 to 242) 140 180 360 1.0 155 110 10000 7000 1600
ERZV20D241 240(216 to 264) 150 200 395 1.0 168 120 10000 7000 1500
ERZV20D271 270(247 to 303) 175 225 455 1.0 190 135 10000 7000 1300
ERZV20D331 330(297 to 363) 210 270 545 1.0 228 160 10000 6500 1100
ERZV20D361 360(324 to 396) 230 300 595 1.0 255 180 10000 6500 1100
ERZV20D391 390(351 to 429) 250 320 650 1.0 275 195 10000 6500 1100
ERZV20D431 430(387 to 473) 275 350 710 1.0 303 215 10000 6500 1000
ERZV20D471 470(423 to 517) 300 385 775 1.0 350 250 10000 6500 900
ERZV20D511 510(459 to 561) 320 410 845 1.0 382 273 10000 6500 800
ERZV20D561 560(504 to 616) 350 450 930 1.0 382 273 7500 6500 750
ERZV20D621 620(558 to 682) 385 505 1025 1.0 382 273 7500 6500 700
ERZV20D681 680(612 to 748) 420 560 1120 1.0 382 273 7500 6500 650
ERZV20D751 750(675 to 825) 460 615 1240 1.0 420 300 7500 6500 600
ERZV20D821 820(738 to 902) 510 670 1355 1.0 460 325 7500 6500 530
ERZV20D911 910(819 to 1001) 550 745 1500 1.0 510 360 7500 6500 500
ERZV20D102 1000(900 to 1100) 625 825 1650 1.0 565 400 7500 6500 450
ERZV20D112 1100(990 to 1210) 680 895 1815 1.0 620 440 7500 6500 400

ERZV20D182 1800(1700 to 1980) 1000 1465 2970 1.0 1020 720 7500 6500 250

✽Ip Measuring current of clamping voltage 180 to 680 : 20 A, 820 to 182 : 100 A

Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 23-Dec-21
66
D type / V20 series
Dimensions in mm (not to scale)
Unit : mm
Part No. D max. T max. W±1.0 H max. L±1.0
ERZV20D180 21.5 5.1 10.0 24.5 1.5
ERZV20D220 21.5 5.2 10.0 24.5 1.6
ERZV20D270 21.5 5.3 10.0 24.5 1.7
ERZV20D330 21.5 5.5 10.0 24.5 1.9 D
T
ERZV20D390 21.5 5.5 10.0 24.5 1.9
ERZV20D470 21.5 5.6 10.0 24.5 2.0
ERZV20D560 21.5 5.7 10.0 24.5 2.1

H
ERZV20D680 21.5 5.8 10.0 24.5 2.2
ERZV20D820 21.5 4.9 10.0 24.5 1.8 L
ERZV20D101 21.5 5.1 10.0 24.5 2.0

20.0 min.
ERZV20D121 21.5 5.3 10.0 24.5 2.2

L
ERZV20D151 21.5 5.6 10.0 24.5 2.5 W

★The following part numbers, kindly also consider corresponding, smaller E Series devices ø1.0 W
with better performance for their size. → Please click here
ERZV20D201 21.5 5.2 10.0 24.5 2.1
ERZV20D221 21.5 5.3 10.0 24.5 2.2
ERZV20D241 21.5 5.4 10.0 24.5 2.3
ERZV20D271 21.5 5.6 10.0 24.5 2.5
ERZV20D331 21.5 5.9 10.0 24.5 2.8 (ERZV20D182)
ERZV20D361 21.5 6.1 10.0 24.5 3.0
ERZV20D391 21.5 6.2 10.0 24.5 3.1 D
T
ERZV20D431 21.5 6.4 10.0 24.5 3.3
ERZV20D471 21.5 6.6 10.0 24.5 3.5

H
ERZV20D511 21.5 6.8 10.0 24.5 3.7

L
ERZV20D561 22.5 7.1 10.0 25.5 4.2 L
ERZV20D621 22.5 7.5 10.0 25.5 4.4

20.0 min
ERZV20D681 22.5 7.8 10.0 25.5 4.7
ERZV20D751 22.5 8.2 10.0 25.5 5.1 ø1.0
ERZV20D821 22.5 8.5 10.0 25.5 5.4
ERZV20D911 22.5 9.0 10.0 25.5 5.9
ERZV20D102 22.5 9.5 10.0 25.5 6.4
ERZV20D112 22.5 10.1 10.0 25.5 7.0
ERZV20D182 23.5 14.8 15.0✽ 28.0 10.7 (±2.0)
✽:W 2

Typical characteristics
Voltage vs. Current+B47:AZ78+B47:AX74 Impulse Derating (Relation between
impulse width and impulse current multiple)
ERZV20D180 to ERZV20D680 ERZV20D180 to ERZV20D680
Max.Leakage Max.Clamping Voltage 10000
400 Current 680
2 times:5 min. interval
560 up to 10 times:2 min. interval
300 up to 106 times : 10 sec. interval
470
390
200
330 1000

270
Impulse current (A)

100 220
90
80 180
70
100
60
Voltage (V)

50
40

30
10

20

1
10
20 100 1000 10000
9
8
Impulse width (μs)
7
6
5 Test current waveform
10–6 to 10–3 A: Direct current
4 10–1 to 104 A: 8/20 μs

3
10-6 10-5 10-4 10-3 10-2 10-1 100 101 102 103 104 105
Current (A)

Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 23-Dec-21
67
D type / V20 series
Typical characteristics
Voltage vs. Current Impulse Derating (Relation between
impulse width and impulse current multiple)

ERZV20D820 to ERZV20D511 ERZV20D820 to ERZV20D511


10000
2 times:5 min. interval
Max.Leakage Max.Clamping Voltage
Current up to 10 times:2 min. interval
2000 511 up to 106 times : 10 sec. interval
471
431
471 391 1000
431
391 361
1000 331
361
271

Impulse current (A)


900
241
800
221
700 100
201
600

500 151
121
Voltage (V)

400
101 10
300 820

200
1
20 100 1000 10000
Impulse width (μs)

100 ERZV20D561 to ERZV20D112


90 10000
80 2 times:5 min. interval
70 up to 10 times:2 min. interval
up to 106 times : 10 sec. interval
60
50 Test current waveform
241
331 10–6 to 10–3 A: Direct current 1000
40 221 10–1 to 104 A: 8/20 μs

30
Impulse current (A)

10-6 10-5 10-4 10-3 10-2 10-1 100 101 102 103 104 105
Current (A)
100

ERZV20D561 to ERZV20D182
5000
Max.Leakage Max.Clamping Voltage 182
Current 10
4000

3000 102
112
911
102 1
821 911 20 100 1000 10000
821 Impulse width (μs)
2000 751
681 ERZV20D182
621
10000
561
2 times:5 min. interval
up to 10 times:2 min. interval
Voltage (V)

up to 106 times : 10 sec. interval

1000
1000
900
Impulse current (A)

800

700

600 100
500

400
10

300
751 Test current waveform
681 10–6 to 10–3 A: Direct current
621 10–1 to 104 A: 8/20 μs
1
200 20 100 1000 10000
10-6 10-5 10-4 10-3 10-2 10-1 100 101 102 103 104 105
Impulse width (μs)
Current (A)

Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 23-Dec-21

68
D type / V series (Leads cut type)
Straight leads cut type (Bulk type)
※ Ratings and characteristics is refer to bulk standard type.

Dimensions in mm (not to scale)


D T**

ød
B

W L*

notes ✽ Dimension “L”: Conforms to each individtual specification.


✽✽ Dimension “T”: Conforms to each individual specification.

Unit : mm
Series 5 7 9 10 14
Varister voltage
Symbol
180 to 471 180 to 511 180 to 511 180 to 511 561 to 751 821 to 112 180 to 511 561 to 751 821 to 112
D 7.0 max. 8.5 max. 11.5max. 11.5max. 12.5max. 12.5max. 15.5 max. 16.0max. 16.0max.
H 10.0 max. 11.5 max. 14.0max. 14.5max. 15.5max. 15.5max. 18.5 max. 19.0max. 19.0max.
W 5.0±1.0 5.0±1.0 5.0±1.0 7.5±1.0 7.5±1.0 7.5±1.0 7.5±1.0 7.5±1.0 7.5±1.0
+0.06 +0.06 +0.06 +0.08 +0.08 +0.08 +0.08 +0.08 +0.08
ød 0.60
-0.05
0.60
-0.05
0.60
-0.05
0.80
-0.05
0.80
-0.05
0.80
-0.05
0.80
-0.05
0.80
-0.05
0.80
-0.05
B 4.0±1.0 4.0±1.0 4.0±1.0 4.0±1.0 4.0±1.0 4.0±1.5 4.0±1.0 4.0±1.0 4.0±1.5
Standard
ERZV05D□□□CS ERZV07D□□□CS ERZV09D□□□CS ERZV10D□□□CS ERZV10D□□□CS ERZV10D□□□C1 ERZV14D□□□CS ERZV14D□□□CS ERZV14D□□□C1
products part No.

Crimped leads cut type (Bulk Type)


※ Ratings and characteristics is refer to bulk standard type.

Dimensions in mm (not to scale)


D T**
A

***
C
C
ød
B

W L*

notes ✽ Dimension “L”: Conforms to each individtual specification.


✽✽ Dimension “T”: Conforms to each individual specification.
✽✽✽ Resin extenyions : No resin below the center of the hook.
Unit : mm
Series 5 7 9 10 14
Varister voltage
Symbol
180 to 471 180 to 511 180 to 511 180 to 511 561 to 751 821 to 112 180 to 511 561 to 751 821 to 112
A 13.0 max. 14.5 max. 17.5 max. 17.5 max. 19.0 max. 20.0 max. 21.0 max. 22.0 max. 23.5 max.
D 7.0 max. 8.5 max. 11.5max. 11.5max. 12.5max. 12.5max. 15.5 max. 16.0max. 16.0max.
C 1.2±0.4 1.2±0.4 1.2±0.4 1.4±0.4 1.4±0.4 1.4±0.4 1.4±0.4 1.4±0.4 1.4±0.4
W 5.0±1.0 5.0±1.0 5.0±1.0 7.5±1.0 7.5±1.0 7.5±1.0 7.5±1.0 7.5±1.0 7.5±1.0
+0.06 +0.06 +0.06 +0.08 +0.08 +0.08 +0.08 +0.08 +0.08
ød 0.60 0.60 0.60 0.80 0.80 0.80 0.80 0.80 0.80
-0.05 -0.05 -0.05 -0.05 -0.05 -0.05 -0.05 -0.05 -0.05
B 4.0±1.0 4.0±1.0 4.0±1.0 4.0±1.0 4.0±1.0 4.0±1.5 4.0±1.0 4.0±1.0 4.0±1.5
Standard
products part No. ERZV05V□□□CS ERZV07V□□□CS ERZV09V□□□CS ERZV10V□□□CS ERZV10V□□□CS ERZV10V□□□C1 ERZV14V□□□CS ERZV14V□□□CS ERZV14V□□□C1

Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 23-Dec-21
69
D type / V series (Taping specifications)
Taping specifications for automated assembly (Straight leads and taping)
※ Ratings and characteristics is refer to bulk standard type.

Dimensions in mm (not to scale)


TypeⅠ・Ⅱ P2 P øD △h
T*

A
P1

W2

H0
F1

H
W0
L

W1
F Position of
H0 dimension

P0 ød øD0 Position of
F1 dimension

t
✽ Dimension “T”: Conforms to each individual specification.

P2 øD △h
TypeⅢ・Ⅳ P T*
A

P1
W2

H0
F1

H
W0
W1
L

F Position of
ød H0 dimension
P0 øD0 Position of
F1 dimension
t

✽ Dimension “T”: Conforms to each individual specification. Unit : mm

Series 5 7 9 10 14
Varister Voltage
180 to 471 180 to 511 180 to 511 180 to 331 361 to 511 561 to 112 180 to 331 361 to 511 561 to 112
記号
Symbol
Type
TypeⅠ TypeⅠ TypeⅠ TypeⅠ TypeⅡ TypeⅡ type Ⅲ Type Ⅳ Type Ⅳ
P 12.7±1.0 12.7±1.0 12.7±1.0 15.0±1.0 15.0±1.0 15.0±1.0 30.0±1.0 30.0±1.0 30.0±1.0
P0 12.7±0.3 12.7±0.3 12.7±0.3 15.0±0.3 15.0±0.3 15.0±0.3 15.0±0.3 15.0±0.3 15.0±0.3
P1 3.85±0.70 3.85±0.70 3.85±0.70 3.75±0.70 3.75±0.70 3.75±0.70 3.75±0.70 3.75±0.70 3.75±0.70
P2 6.35±1.30 6.35±1.30 6.35±1.30 7.5±1.3 7.5±1.3 7.5±1.3 7.5±1.3 7.5±1.3 7.5±1.3
+0.06 +0.06 +0.06 +0.08 +0.08 +0.08 +0.08 +0.08 +0.08
ød 0.60 0.60 0.60 0.80 0.80 0.80 0.80 0.80 0.80
-0.05 -0.05 -0.05 -0.05 -0.05 -0.05 -0.05 -0.05 -0.05
F 5.0±0.5 5.0±0.5 5.0±0.5 7.5±0.5 7.5±0.5 7.5±0.5 7.5±0.5 7.5±0.5 7.5±0.5
△h 0±2 0±2 0±2 0±2 0±2 0±2 0±2 0±2 0±2
+1.0 +1.0 +1.0 +1.0 +1.0 +1.0 +1.0 +1.0 +1.0
W 18.0
-0.5
18.0
-0.5
18.0
-0.5
18.0
-0.5
18.0
-0.5
18.0
-0.5
18.0
-0.5
18.0
-0.5
18.0
-0.5
W0 5.0 min. 5.0 min. 5.0 min. 5.0 min. 5.0 min. 5.0 min. 5.0 min. 5.0 min. 5.0 min.
W1 9.0±0.5 9.0±0.5 9.0±0.5 9.0±0.5 9.0±0.5 9.0±0.5 9.0±0.5 9.0±0.5 9.0±0.5
W2 3 max. 3 max. 3 max. 3 max. 3 max. 3 max. 3 max. 3 max. 3 max.
H Approx. 20 Approx. 20 Approx. 20 Approx. 22 Approx. 22 Approx. 22 Approx. 22 Approx. 22 Approx. 22
+2.0 +2.0
H0 17.0±0.5 17.0±0.5 17.0±0.5 18.0 ―― ―― 18.0 ―― ――
0 0
+0.75 +0.75 +0.75 +0.75
F1 ―― ―― ―― ―― 16.00 16.00 ―― 16.00 16.00
-0.5 -0.5 -0.5 -0.5
øD0 ø4.0±0.2 ø4.0±0.2 ø4.0±0.2 ø4.0±0.2 ø4.0±0.2 ø4.0±0.2 ø4.0±0.2 ø4.0±0.2 ø4.0±0.2
t 0.6±0.3 0.6±0.3 0.6±0.3 0.6±0.3 0.6±0.3 0.6±0.3 0.6±0.3 0.6±0.3 0.6±0.3
L 11 max. 11 max. 11 max. 11 max. 11 max. 11 max. 11 max. 11 max. 11 max.
øD 7.0 max. 8.5 max. 11.5 max. 11.5 max. 11.5 max. 12.5 max. 15.5 max. 15.5 max. 16.0 max.
A 10.0 max. 11.5 max. 14.0 max. 14.5 max. 14.5 max. 15.5 max. 18.5 max. 18.5 max. 19.0 max.
Standard
Products Part No. ERZVA5D□□□ ERZVA7D□□□ ERZVA9D□□□ ERZVGAD□□□ ERZVGAD□□□ ERZVGAD□□□ ERZVGED□□□ ERZVGED□□□ ERZVGED□□□

Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 23-Dec-21
70
D type / V series (Taping specifications)
Taping specifications for automated assembly (Crimped leads and taping)
※ Ratings and characteristics is refer to bulk standard type.

Dimensions in mm (not to scale)


P2 P
TypeⅠ øD △h
T*

A
P1

W2

H0
H
W0
W1
L

W
F

P0 ød øD0

t
✽ Dimension “T”: Conforms to each individual specification.
P2 øD △h
P T*
TypeⅡ
A

P1 W0 W2

H0
H
W1
L

F
W
ød
P0 øD0

✽ Dimension “T”: Conforms to each individual specification. t Unit : mm

Series 5 7 9 10 14
Varister Voltage
180 to 471 180 to 511 180 to 511 180 to 331 361 to 511 561 to 112 180 to 331 361 to 511 561 to 112
Type
Symbol
TypeⅠ TypeⅠ TypeⅠ TypeⅠ TypeⅠ TypeⅠ TypeⅡ TypeⅡ TypeⅡ
P 12.7±1.0 12.7±1.0 12.7±1.0 15.0±1.0 15.0±1.0 15.0±1.0 30.0±1.0 30.0±1.0 30.0±1.0
P0 12.7±0.3 12.7±0.3 12.7±0.3 15.0±0.3 15.0±0.3 15.0±0.3 15.0±0.3 15.0±0.3 15.0±0.3
P1 3.85±0.70 3.85±0.70 3.85±0.70 3.75±0.70 3.75±0.70 3.75±0.70 3.75±0.70 3.75±0.70 3.75±0.70
P2 6.35±1.30 6.35±1.30 6.35±1.30 7.5±1.3 7.5±1.3 7.5±1.3 7.5±1.3 7.5±1.3 7.5±1.3
+0.06 +0.06 +0.06 +0.08 +0.08 +0.08 +0.08 +0.08 +0.08
ød 0.60
-0.05
0.60
-0.05
0.60
-0.05
0.80
-0.05
0.80
-0.05
0.80
-0.05
0.80
-0.05
0.80
-0.05
0.80
-0.05
F 5.0±0.5 5.0±0.5 5.0±0.5 7.5±0.5 7.5±0.5 7.5±0.5 7.5±0.5 7.5±0.5 7.5±0.5
△h 0±2 0±2 0±2 0±2 0±2 0±2 0±2 0±2 0±2
W 18.0 +1.0
-0.5 18.0 +1.0
-0.5 18.0 +1.0
-0.5 18.0 +1.0
-0.5 18.0 +1.0
-0.5 18.0 +1.0
-0.5 18.0 +1.0
-0.5 18.0 +1.0
-0.5 18.0 +1.0
-0.5
W0 5.0 min. 5.0 min. 5.0 min. 5.0 min. 5.0 min. 5.0 min. 5.0 min. 5.0 min. 5.0 min.
W1 9.0±0.5 9.0±0.5 9.0±0.5 9.0±0.5 9.0±0.5 9.0±0.5 9.0±0.5 9.0±0.5 9.0±0.5
W2 3 max. 3 max. 3 max. 3 max. 3 max. 3 max. 3 max. 3 max. 3 max.
H Approx. 22 Approx. 22 Approx. 22 Approx. 22 Approx. 22 Approx. 22 Approx. 22 Approx. 22 Approx. 22
H0 17.0±0.5 17.0±0.5 17.0±0.5 16.0±0.5 16.0±0.5 16.0±0.5 16.0±0.5 16.0±0.5 16.0±0.5
øD0 ø4.0±0.2 ø4.0±0.2 ø4.0±0.2 ø4.0±0.2 ø4.0±0.2 ø4.0±0.2 ø4.0±0.2 ø4.0±0.2 ø4.0±0.2
t 0.6±0.3 0.6±0.3 0.6±0.3 0.6±0.3 0.6±0.3 0.6±0.3 0.6±0.3 0.6±0.3 0.6±0.3
L 11 max. 11 max. 11 max. 11 max. 11 max. 11 max. 11 max. 11 max. 11 max.
øD 7.0 max. 8.5 max. 11.5 max. 11.5 max. 11.5 max. 12.5 max. 15.5 max. 15.5 max. 16.0 max.
A 13.0 max. 14.5 max. 17.5 max. 17.5 max. 17.5 max. *(refer) 21.0 max. 21.0 max. *(refer)

Standard
Products Part No. ERZVA5V□□□ ERZVA7V□□□ ERZVA9V□□□ ERZVEAV□□□ ERZVEAV□□□ ERZVEAV□□□ ERZVEEV□□□ ERZVEEV□□□ ERZVEEV□□□

✽Dimension "A"
Part No. 10 Series 14 Series Part No. 10 Series 14 Series
ERZV□□V561 19.0 max. 22.0 max. ERZV□□V821 20.0 max. 23.5 max.
ERZV□□V621 19.0 max. 22.0 max. ERZV□□V911 20.0 max. 23.5 max.
ERZV□□V681 19.0 max. 22.0 max. ERZV□□V102 20.0 max. 23.5 max.
ERZV□□V751 19.0 max. 22.0 max. ERZV□□V112 20.0 max. 23.5 max.

Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 23-Dec-21
71
D type / V series
Application note for safety standards
● Approvals products lists in "Reference Guide to Standard Products."
● UL and VDE : Registered in "Type name", it isn’t registered in "Panasonic Part No."
● CQC : Registered in "Panasonic Part No."
● "Rated Voltages" are specified for UL recognized components in list shown below.

The AC rated voltage and maximum allowable voltage


Maximum allowable voltage Rated voltage (Vrms)
Type name
ACrms (V) DC (V) UL1449 CSA C22.2 No.269.5

V✽820U 50 65 45 N/A
V✽101U 60 85 55 N/A
V✽121U 75 100 68 N/A
V✽151U 95 125 86 N/A
V✽201U 130 170 118 118
V✽221U 140 180 127 127
V✽241U 150 200 136 136
V✽271U 175 225 159 159
V✽331U 210 270 189 189
V✽361U 230 300 209 209
V✽391U 250 320 227 227
V✽431U 275 350 250 250
V✽471U 300 385 272 272
V✽511U 320 410 291 291
V✽561U 350 450 320 320
V✽621U 385 505 350 350
V✽681U 420 560 381 381
V✽751U 460 615 418 418
V✽821U 510 670 463 463
V✽911U 550 745 500 500
V✽102U 625 825 568 568
V✽112U 680 895 600 618
V✽182U 1000 1465 600 909

✽:5 Series is blank, 7 series is 7, 9 series is 9, 10 series is 10, 14 series is 14, 20 series is 20

Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 23-Dec-21
72
D type / V series
Explanation of the contents
Mark Explanation of the content
V✽□□□ Abbreviation of
□□□
Part No.
V✽□□□U (Type name) Nominal varistor volage

Marking Factory None : Japan



identication mark Q : Indonesia

2019 : 9, 2020 : K, 2021 : A


◆*1 Year code
2022 : B, 2023 : C, 2024 : D
Jan : 1 to Sep : 9,
◇ Monthly code
Oct. : 0, Nov. : N,Dec. : D
UL recognized components mark
CSA monogram

✽: 5 series is blank, 7 series is 7, 9 series is 9, 10 series is 10, 14 series is 14,


20 series is 20
*1: If the 10's digit of a Christian year is an even year, as an end abbreviation, an
alphabetic character is used.
1 : A, 2 : B, 3 : C, 4 : D, 5 : E, 6 : F, 7 : G, 8 : H, 9 : J, 0 : K
If the 10's digit of a Christian year is an odd year, as an end abbreviation, a
number is used.

Marking contents
Series (Example) 5 7 9 10 14 20
Varister voltage (ERZV05D□□□) (ERZV07D□□□) (ERZV09D□□□) (ERZV10D□□□) (ERZV14D□□□) (ERZV20D□□□)

ZNR ZNR ZNR


V□□□ V7□□□ V9□□□
180 to 680 V10□□□ V14□□□ V20□□□
○◆◇ ○◆◇ ○◆◇
○◆◇ ○◆◇ ○◆◇

ZNR ZNR ZNR


V□□□U V7□□□U V9□□□U
820 to 151 V10□□□U V14□□□U V20□□□U
○◆◇ ○◆◇ ○◆◇
○◆◇ ○◆◇ ○◆◇

ZNR ZNR ZNR


V□□□U V7□□□U V9□□□U
201 or more V10□□□U V14□□□U V20□□□U
○◆◇ ○◆◇ ○◆◇
○◆◇ ○◆◇ ○◆◇

Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
73
D type / V series
Performance characteristics
Characteristics Test methods / description Specifications
Electrical measurements (initial/after tests) shall be conducted at temperature of 5 to
Standard test condition ―
35 ℃, relative humidity of maximum 85 %.
The voltage between two terminals with the specified measuring current CmA DC
Varistor voltage applied is called VC or VCmA. The mea sure ment shall be made as fast as possible to
avoid heat affection.
Maximum The maximum sinusoidal RMS voltage or maximum DC voltage that can be applied
allowable voltage continuously.
The maximum voltage between two terminals with the specified
standard impulse current (8/20 μs) illustrated below applied.
100
90

Clamping voltage (%)


Current 50

To meet the specified value.


10
0 8 μs Time
20 μs

Rated power The power that can be applied in the specified ambient temperature.
The maximum energy within the varistor voltage change of ±10 % when a single
Maximum energy
impulse current of 2 ms or 10/1000 μs is applied.

Maximum The maximum current within the varistor voltage change of ±10 % when a standard
peak current 2times impulse current of 8/20 μs is applied two times with an interval of 5 minutes.
(Withstanding
Surge
The maximum current within the varistor voltage change of ±10 % with a single
Current) 1time
standard impulse current of 8/20 μs is applied.

Temperature coefficient of VCmA at 85 ℃–VCmA at 25 ℃ 1


× 100(%/℃) 0 to ‒0.05 %/ ℃ max.
varistor voltage VCmA at 25 ℃ 60
Capacitance shall be measured at 1 kHz ±10 %, 1 Vrms max.
Electrical

Capacitance To meet the specified value.


(1 MHz ±10 % below 100 pF), 0 V bias and 20±2 ℃.
The specified voltage shall be applied between both terminals of the specimen
connected together and metal foil closely wrapped round its body for 1 minute.

Withstanding voltage
Classification (Nominal varistor voltage) Test Voltage (AC) No breakdown
(Body Insulation)
V0.1 mA,V1 mA ≦ 330 V 1000 Vrms
V0.1 mA,V1 mA > 330 V 1500 Vrms

The change of VC shall be measured after the impulse current listed below is applied
10000 or 100000 times continuously with the interval of 10 seconds at room
temperature.
Item Impulse Life(Ⅰ) Impulse Life(Ⅱ)
Times ×104 Times ×105 Times
Part No. Current Impulse Current
ERZV05D180 to ERZV05D680 8 A (8/20 μs) 5 A (8/20 μs)
ERZV07D180 to ERZV07D680 25 A (8/20 μs) 15 A (8/20 μs)
ERZV09D180 to ERZV09D680 50 A (8/20 μs) 35 A (8/20 μs)
ERZV10D180 to ERZV10D680 50 A (8/20 μs) 35 A (8/20 μs)
Impulse life ERZV14D180 to ERZV14D680 90 A (8/20 μs) 50 A (8/20 μs) ΔVCmA/VCmA ≦ ±10 %
ERZV20D180 to ERZV20D680 130 A (8/20 μs) 65 A (8/20 μs)
ERZV05D820 to ERZV05D471 40 A (8/20 μs) 25 A (8/20 μs)
ERZV07D820 to ERZV07D511 100 A (8/20 μs) 60 A (8/20 μs)
ERZV09D820 to ERZV09D511 150 A (8/20 μs) 85 A (8/20 μs)
ERZV10D820 to ERZV10D112 150 A (8/20 μs) 85 A (8/20 μs)
ERZV10D182CS 120 A (8/20 μs) 75 A (8/20 μs)
ERZV14D820 to ERZV14D112 200 A (8/20 μs) 110 A (8/20 μs)
ERZV14D182CS 150 A (8/20 μs) 90 A (8/20 μs)
ERZV20D820 to ERZV20D112 250 A (8/20 μs) 120 A (8/20 μs)
ERZV20D182 200 A (8/20 μs) 100 A (8/20 μs)

Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
74
D type / V series
Performance characteristics
Characteristics Test methods / description Specifications
After gradually applying the force specified below and keeping the unit fixed for 10
seconds, the terminal shall be visually examined for any damage.
Robustness of
terminations Terminal diameter Force
(Tensile) ø0.6 mm, ø0.8 mm 9.8 N
ø1.0 mm 19.6 N

The unit shall be secured with its terminal kept vertical and the force
specified below shall be applied in the axial direction.
The terminal shall gradually be bent by 90 ° in one direction, then 90 °
in the opposite direction, and again back to the original position. No remarkable mechanical
Robustness of The damage of the terminal shall be visually examined. damage
terminations
(Bending) Terminal diameter Force
ø0.6 mm, ø0.8 mm 4.9 N
Mechanical

ø1.0 mm 9.8 N

After repeadly applying a single harmonic vibration (amplitude: 0.75 mm, double
amplitude: 1.5 mm) with 1 minute vibration frequency cycles (10 Hz to 55 Hz to 10 Hz)
Vibration
to each of three perpendicular directions for 2 hours. Thereafter, the unit shall be
visually examined.

Approximately 95 %
After dipping the terminals to a depth of approximately 3 mm from the body in a of the termainals shall
Solderability
soldering bath of 235±5 °C for 2±0.5 seconds, the terminal shall be visually examined. be covered with new
solder uniformly.

After each lead shall be dipped into a solder bath having a temperature
of 260±5 °C to a point 2.0 to 2.5 mm from the body of the unit, using
Resistance to
shielding board (t=1.5 mm), be held there for 10±1 s and then be stored ΔVCmA/VCmA≦ ±5 %
soldering heat
at room temperature and normal humidity for 1 to 2 hours. The change of
VCmA and mechanical damages shall be examined.

The specimen shall be subjected to 125±2 °C for 1000 hours in a thermostatic bath
High temperature
without load and then stored at room temperature and normal humidity for 1 to 2 hours.
storage/Dry heat
Thereafter, the change of VCmA shall be measured.
ΔVCmA/VCmA≦ ±5 %
The specimen shall be subjected to 40±2 °C, 90 to 95 % RH for 1000 hours without
Humidity load and then stored at room temperature and normal humidity for 1 to 2 hours.
Thereafter, the change of VCmA shall be measured.

The temperature cycle shown below shall be repeated five cycles and then stored at
room temperature and normal humidity for 1 to 2 hours. The change of VCmA and
mechanical damage shall be examined.

Step Temperature (°C) Period (minutes) ΔVCmA/VCmA≦ ±5 %


Temperature cycle No remarkable
Environmental

1 –40±3 30±3
mechanical damage
2 Room temperature 15±3
3 125±2 30±3
4 Room temperature 15±3

After being continuously applied the Maximum Allowable Voltage at 85±2 °C for 1000
High temperature
hours, the specimen shall be stored at room temperature and normal humidity for 1 to
load/Dry heat load
2 hours. Thereafter, the change of VCmA shall be measured.
ΔVCmA/VCmA ≦ ±10 %
The specimen shall be subjected to 40±2 °C, 90 to 95 % RH and the
Damp heat load/ Maximum Allowable Voltage for 1000 hours and then stored at room
Humidity load temperature and normal humidity for 1 to 2 hours. Thereafter, the change of VCmA shall
be measured.

The specimen shall be subjected to –40±2 °C without load for 1000 hours and then
Low temperature
stored at room temperature and normal humidity for 1 to 2 hours. Thereafter, the ΔVCmA/VCmA ≦ ±5 %
storage/Cold
change of VCmA shall be measured.

Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
75
D type / V series
Minimum quantity / Packing unit
Minimum
Packing quantity Carton (about)
Product Series / Type Part number quantity
in carton L×W×H (mm)
/ Packing unit
ERZV05D180 to 271 100 10000 210×340×160
ERZV05D331 to 471 100 10000 210×340×180
ERZV07D180 to 470 100 10000 210×340×160
ERZV07D560 to 680 100 10000 210×340×180
ERZV07D820 to 121 100 10000 210×340×160
ERZV07D151 to 271 100 10000 210×340×180
ERZV07D331 to 511 100 5000 210×340×110
ERZV09D180 to 121 100 5000 210×340×160
ERZV09D151 to 271 100 4000 210×340×130
ERZV09D331 to 511 100 4000 210×340×160
ERZV10D180 to 121 50 5000 210×340×160
ERZV10D151 to 271 50 4000 210×340×130
ERZV10D331 to 621 50 4000 210×340×160
Straight leads
ERZV10D681 to 821 50 2000 210×340×*80
<Bulk>
ERZV10D911 to 112 50 2000 210×340×110
ERZV10D182CS 50 1000 210×340×*80
ERZV14D180 to 121 50 3000 210×340×110
ERZV14D151 to 271 50 3000 210×340×130
ERZV14D331 to 621 50 2000 210×340×110
D type ERZV14D681 to 821 50 2000 210×340×110
V series ERZV14D911 to 112 50 1000 210×340×*80
ERZV14D182CS 50 1000 210×340×*80
ERZV20D180 to 271 50 2000 210×340×160
ERZV20D331 to 511 50 1000 210×340×*80
ERZV20D561 to 821 50 1000 210×340×110
ERZV20D911 to 112 50 1000 210×340×110
ERZV20D182 25 500 210×340×*80
ERZV05D(V)180CS to 271CS 100 10000 210×340×*80
“ZNR” ERZV05D(V)331CS to 471CS 100 10000 210×340×110
Transient/ ERZV07D(V)180CS to 271CS 100 10000 210×340×*80
surge ERZV07D(V)331CS to 511CS 100 10000 210×340×110
absorbers ERZV09D(V)180CS to 121CS 100 5000 210×340×110
ERZV09D(V)151CS to 511CS 100 4000 210×340×*80
Leads cut type
ERZV10D(V)180CS to 121CS 100 5000 210×340×110
<Bulk>
ERZV10D(V)151CS to 621CS 100 4000 210×340×*80
ERZV10D(V)681CS to 751CS 100 2000 210×340×*80
ERZV10D(V)821C1 to 112C1 100 2000 210×340×*80
ERZV14D(V)180CS to 271CS 100 3000 210×340×*80
ERZV14D(V)331CS to 821C1 100 2000 210×340×*80
ERZV14D(V)911C1 to 112C1 100 1000 210×340×*80
ERZVA5D180 to 271 1000 10000 360×320×260
ERZVA5D331 to 471 1000 10000 400×360×260
ERZVA7D180 to 271 1000 10000 400×360×260
ERZVA7D331 to 511 1000 10000 470×360×260
Straight leads ERZVA9D180 to 271 1000 10000 400×360×260
and taped ERZVA9D331 to 511 1000 10000 470×360×260
ERZVGAD180 to 621 1000 5000 360×310×320
ERZVGAD681 to 112 500 2500 360×270×320
ERZVGED180 to 511 500 2500 360×310×320
D type ERZVGED561 to 112 250 1250 360×270×320
V series ERZVA5V180 to 271 1000 10000 360×320×260
ERZVA5V331 to 471 1000 10000 400×360×260
ERZVA7V180 to 271 1000 10000 400×360×260
ERZVA7V331 to 511 1000 10000 470×360×260
Crimped lead ERZVA9V180 to 271 1000 10000 400×360×300
and taped ERZVA9V331 to 511 1000 10000 470×360×300
ERZVEAV180 to 621 1000 5000 360×310×320
ERZVEAV681 to 112 500 2500 360×270×320
ERZVEEV180 to 511 500 2500 360×310×320
ERZVEEV561 to 112 250 1250 360×270×320
Part No., quantity and country of origin are designated on outer packages in English.
※ Please contact local sales office about packing specifications.
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
76
Varistors (ZNR Surge Absorber)
SMD type
HF series
Features
● Meet for load dump surge test (JASO D 001-94) [Vp=70 V,τ=200 ms,Ri=0.8 Ω]
● Meet for load dump surge test ISO7637-2 and ISO16750-2
● Suitable for requirements of automotive
● Compact size SMD
● Meet flow/reflow/iron soldering
● Strong against “Soldering heat shock” due to molded construction
● AEC-Q200 compliant
● RoHS compliant

Recommended applications
● Protection of body & accessory ECU about DC12 V automotive against load dump surge

■ As for handling precautions and minimum quantity / Packing unit please see related information.

Explanation of part numbers


T ERJS02 ~ ERJS1Tシリーズ
1 2 3 4 5 6 7 8 9 10 11 12

E R Z H F 2 M 2 2 0 F
Product code Series Construction Nominal Design No.
Varistor voltage

Embossed taping

Construction
① ②
① Multilayer varistor ZnO, others
② Mold resin Epoxy (UL94 V-0 approved)
ERZHF2M220F : Sn plated Cu alloy
③ Lead terminal
ERZHF2M220D / ERZHF2M270 : Sn plated Ni-Fe alloy

Dimensions in mm (not to scale)

Unit : mm

Dimensions
Part No.
W L H S E
H

ERZHF2M220F
S S 5.5±0.5
E ERZHF2M220D 6.4±0.4 8.0±0.5 1.3±0.3 2.5±0.2
ERZHF2M270 4.5±0.5
L W

Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 20-Jan-23
77
SMD type / HF series
Ratings and characteristics
● Operating temperature range : ERZHF2M220F -55 to 150 ℃, ERZHF2M220D/ERZHF2M270 -40 to 125 ℃
● Storage temperature range : ERZHF2M220F -55 to 150 ℃, ERZHF2M220D/ERZHF2M270 -40 to 125 ℃

Varistor Maximum Load dump surge


Short time Clamping
voltage allowable Load dump energy ISO7637-2
Part No. over-voltage voltage TEST A
at 1 mA voltage surge
(V) DC (V) DC (V) (V)at Ip 5(A) (J)
ERZHF2M220F JASO 50 max. 10 times
20 to 23.2 24 35 max.
ERZHF2M220D 16 Category:A, A-1
5 min. ー
ERZHF2M270 27±20 % 43 max. 70 V, 1 time

Marking contents

① Product name ZNR Surge Absorbers


① ZNR ② Abbreviation of P/N HF220F (ERZHF2M220F), HF220 (ERZHF2M220D), HF270 (ERZHF2M270)
②H F 2 2 0 F ◆ Yearly
2010:0, 2021:1,・・・, 2019:9, 2020:A, 2021:B,・・・,
2027:H, 2028:J,・・・, 2032:N, 2033:P, 2034:R,・・・, 2039:W (30 year cycle)
③ ◆◇●〇■ ◇ Monthly Jan.: 1, Feb.: 2, ・・・, Aug.: 8, Sep.: 9, Oct.: O, Nov.: N, Dec.: D
③ Date code 1st to 9th: 1 to 9, 10th: A, 11th: B, ・・・, 17th: H, 18th: J, ・・・,
● Daily
22nd: N, 23rd: P, 24th: R, ・・・, 30th: X, 31st: Y
〇 Suffix-1 A single digit of alphanumeric
■ Suffix-2 A single digit of alphanumeric

Minimum quantity
● Packing quantity
Minimum quantity Packing quantity Carton (about)
Product Series / Type Part number / Packing unit in carton L×W×H (mm)
“ZNR” ERZHF2M220F
SMD Embossed 800 3200
Transient/surge ERZHF2M220D 340×345×105
absorbers
type (HF)
ERZHF2M270 1000 4000
※ Part No., quantity and country of origin are designated on outer packages in English. ※ Please contact local sales office about packing specifications.

● Embossed taping
t1
Feeding hole Chip pocket
Width of tape :16 mm
øD0 P2 P0
E
F
B

A P1
t2 Chip component Direction of feed

Unit : mm

Part No. A B W F E P1 P2 P0 øD0 t1 t2


ERZHF2M220F
9.0 max.
ERZHF2M220D 7.5 max. 11.9 max. 16.0±0.3 7.5±0.1 1.75±0.10 12.0±0.1 2.0±0.1 4.0±0.1 1.5+0.1/0 0.8 max.
ERZHF2M270 8.0 max.

● Reel
T

E
C
B

r øD Unit : mm

Part No. A B C øD E
382 max. 50 min. 13.0±0.5 21.0±0.8 2.0±0.5
t ERZHF2M W T t r
A W 16.4+2.0/0 22.4 max. 2.5±0.5 1.0

Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 20-Jan-23
78
SMD type / HF series
Performance characteristics
Characteristics Test methods Specifications

Environmental conditions under which every measuring is done without doubt on the
Standard test condition measuring results. Unless specially, specified, temperature, relative humidity are 5 ° -
C to 35 °C, 45 to 85% RH respectively.

Maximum allowable The maximum DC voltage that can be applied continuously in the specified
voltage environmental temperature range.

Short time over-voltage The maximum DC Voltage that can be applied specified period without breakdown.
To meet the
Voltage between both terminals of ZNR measured when 1 mA of DC current is specified value
Varistor voltage applied under standard conditions. It is called V1. Measuring the varistor voltage
should be made promptly to avoid heat affection.
The maximum voltage between two terminals with the specified impulse current (8/20
Clamping voltage
μs).
The test waveform of transient voltage which specified JASO Category
A A-1 70 V without breakdown.

Load dump surge Vp=70 V No breakdown


36.8 %

PS Voltage
0V
τ=200 ms

Surge energy which can be applied at 10 times on the condition of


ISO16750-2 TEST A.
td
US

Load dump surge


No breakdown
energy

UA
0.1(US-UA) PS Voltage

0V
※ Please Check Specification of the products about Mechanical & Environmental etc. requirements.

Recommendation land size

Land
8.0

Product
3.0

Occupied Space
6.4

5.0

10.0
Unit : mm

Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 20-Jan-23
79
Varistors (ZNR Surge Absorber)
SMD type
VF series
Features
●Large withstanding surge current capability in compact sizes
●Designed for flow/reflow solderings
●Low clamping voltage
●RoHS compliant

Recommended applications
●Protection of communication modules (Modem, xDSL, Terminal Adopter)
●Protection of consumer, industrial equipment
●Absorption of switching surge from relays

■ As for handling precautions and minimum quantity / Packing unit please see related information.

Applicable Standards
●CQC(GB/T10193,GB/T10194)
Registered in "Panasonic Part No."

Explanation of part numbers


1 2 3 4 5 6 7 8 9 10 11 12

E R Z V F M
Product Code Series Construction Norminal Design No.
Varistor Voltage
Packaging style
1 Bulk
2 Taping

Construction

② ④
① ZNR element ZnO etc.
② Resin mold Epoxy Resin(UL94V-0 approved)

③ Conductive adhesive Silver
① ④ Electrode Silver
⑤ Lead terminals Sn plated Ni-Fe Alloy

Dimensions in mm (not to scale)


Unit : mm
Part No. W L H S E
ERZVF□M□□□ 6.0±0.4 8.0±0.5 3.2±0.3 1.3±0.3 2.5±0.2
H

S S E
L W

Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
80
SMD type / VF series
Ratings and characteristics
●Operating temperature range : -40 to 85 ℃ ●Storage temperature range : ‒40 to 125℃

Varistor Clamping Maximum Maximum


Maximum Rated peak current
voltage voltage at Ip energy
allowable voltage power (8/20μs,
Part No. at 1 mA (max.) (2 ms) 2 times)

Measuring current
(V) ACrms (V) DC (V) (V) (W) (J) (A)
(A)
ERZVF□M220 22(20 to 24) 14 18 43 2.5 0.02 0.9 125
ERZVF□M270 27(24 to 30) 17 22 53 2.5 0.02 1.0 125
ERZVF□M330 33(30 to 36) 20 26 65 2.5 0.02 1.2 125
ERZVF□M390 39(35 to 43) 25 31 77 2.5 0.02 1.5 125
ERZVF□M470 47(42 to 52) 30 38 93 2.5 0.02 1.8 125
ERZVF□M560 56(50 to 62) 35 45 110 2.5 0.02 2.2 125
ERZVF□M680 68(61 to 75) 40 56 135 2.5 0.02 2.5 125
ERZVF□M820 82(74 to 90) 50 65 135 10 0.25 3.5 600
ERZVF□M101 100(90 to 110) 60 85 165 10 0.25 4.0 600
ERZVF□M121 120(108 to 132) 75 100 200 10 0.25 5.0 600
ERZVF□M151 150(135 to 165) 95 125 250 10 0.25 6.0 600
ERZVF□M201 200(185 to 225) 130 170 340 10 0.25 8.0 600
ERZVF□M221 220(198 to 242) 140 180 360 10 0.25 9.0 600
ERZVF□M241 240(216 to 264) 150 200 395 10 0.25 10.0 600
ERZVF□M271 270(247 to 303) 175 225 455 10 0.25 12.0 600
ERZVF□M331 330(297 to 363) 210 270 545 10 0.1 8.0 300
ERZVF□M361 360(324 to 396) 230 300 595 10 0.1 9.0 300
ERZVF□M391 390(351 to 429) 250 320 650 10 0.1 9.0 300
ERZVF□M431 430(387 to 473) 275 350 710 10 0.1 10.0 300
ERZVF□M471 470(423 to 517) 300 385 775 10 0.1 10.0 300

Packaging Style Code: “1” for bulk, “2” for embossed taping

Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
81
SMD type / VF series
Typical characteristics
Voltage vs. Current Impulse Derating (Relation between
impulse width and impulse current multiple)

ERZVF1(2)M220 to ERZVF1(2)M680 ERZVF1(2)M220 to ERZVF1(2)M680


300
200
Max.Leakage Max.Clamping Voltage 2 times:5 min. interval
400 Current up to 10 times:2 min. interval
100
up to 106 times : 10 sec. interval
300 50
680 40
560 30
200
20

Impulse current (A)


470
390 10
330
100 270 5
90 4
80 220 3
2
Voltage (V)

70
60 1
50
0.5
40 0.4
0.3
30 0.2

0.1
20

20 100 1000 10000

10 Impulse width (μs)


9
8 390
7 330
6
ERZVF1(2)M820 to ERZVF1(2)M271
Test current waveform 2000
5
10–6 to 10–3 A: Direct current
4 10–1 to 103 A: 8/20 μs 1000 2 times:5 min. interval
500 up to 10 times:2 min. interval
3 400 up to 106 times : 10 sec. interval
10-6 10-5 10-4 10-3 10-2 10-1 100 101 102 103 104 300
200
Current (A)
100
Impulse current (A)

50
40
30
20

10
5
4
3
2
ERZVF1(2)M820 to ERZVF1(2)M471 1

Max.Leakage Max.Clamping Voltage


Current
2000 0.1
20 100 1000 10000
Impulse width (μs)
471
1000 431
900 431 391 ERZVF1(2)M331 to ERZVF1(2)M471
800 391 361
700 1000
271
600 241 2 times:5 min. interval
221
Voltage (V)

500 up to 10 times:2 min. interval


201 up to 106 times : 10 sec. interval
400 151
100
300 121
Impulse current (A)

101

200 820

10

100
90
80
1
70
60
50 Test current waveform
10–6 to 10–3 A: Direct current
10–1 to 104 A: 8/20 μs
40 241
221 0.1
30
20 100 1000 10000
10-6 10-5 10-4 10-3 10-2 10-1 100 101 102 103 104
Impulse width (μs)
Current (A)

Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
82
SMD type / VF series
Marking contents

① ①Product Name ZNR Surge Absorbers


ZNR ② Series VF□M VF Series
VFM □□ ③ Abbreviation of The first two digits are signifi cant figures and the third one denotes
② ③ Part No. the number of zeros following.
01 Left✽ (Year) 2019:9, 2020:K, 2021:A, 2022:B, 2023:C, 2024:D
④Date Code
④ Right(Month) Jan. to Sep.:1 to 9, Oct.:O, Nov.:N, Dec.:D

* If the 10's digit of a Christian year is an even year, as an end abbreviation, an


alphabetic character is used.
1 : A, 2 : B, 3 : C, 4 : D, 5 : E, 6 : F, 7 : G, 8 : H, 9 : J, 0 : K
If the 10's digit of a Christian year is an odd year, as an end abbreviation, a number is used.

Minimum quantity
●Packing Quantity

Minimum quantity Packing quantity Carton (about)


Product Series / Type Part number / Packing unit in carton L×W×H (mm)
“ZNR” Bulk (VF) ERZVF1 200 2000 210×340×80
SMD
Transient/surge
absorbers
type Embossed (VF) ERZVF2 2000 6000 340×345×75

※ Part No., quantity and country of origin are designated on outer packages in English.
※ Please contact local sales office about packing specifications.

●Reel ●Embossed Taping


T

E W=16mm
C t1 Feeding hole
Chip pocket
øD0 P2 P0

r D E
A F

Chip component P1 Tape running drunning


t2
W t
A (not to scale)

Unit : mm Unit : mm

Part No. A B C Part No. A B W


ERZVF□M□□□ 382 max. 50 min. 13.0±0.5 ERZVF□M□□□ 6.8±0.2 11.9 max. 16.0±0.3

Part No. D E W Part No. F E P1


+2.0
ERZVF□M□□□ 21.0±0.8 2.0±0.5 16.4 ..0
ERZVF□M□□□ 7.5±0.10 1.75±0.10 8.0±0.1

Part No. T t r Part No. P2 P0 øD0


+0.1
ERZVF□M□□□ 22.4 max. 2.5±0.5 1.0 ERZVF□M□□□ 2.0±0.1 4.0±0.1 1.5 ..0

Part No. t1 t2

ERZVF□M□□□ 0.6 max. 6.5 max.

Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
83
SMD type / VF series
Performance characteristics
Characteristics Test methods Specifications
Electrical measurements (initial/after tests) shall be conducted at temperature of 5 to
Standard test condition
35 ℃, relative humidity of maximum 85 %. ―
The voltage betwen two terminals with the specified measuring current 1 mA
Varistor voltage DC applied is called V1 or V1 mA. The measurement shall be made as fast as
possible to avoid heat affection.
Maximum The maximum sinusoidal RMS voltage or maximum DC voltage that can be
allowable voltage applied continuously.
The maximum voltage between two terminals with the specified
Clamping voltage
standard impulse current (8/20 μs) illustrated below applied. To meet the
Rated power The power that can be applied in the specified ambient temperature. specified value.

Maximum energy of less than ±10 % of the varistor voltage


Maximum energy
change when the standard impulse (2 ms) is applied one time.
Maximum
Maximum current of less than ±10 % of the varistor voltage change
peak current
when impulse current (8/20 μs) is applied twice continuously with an interval
(Withstanding surge
of 5 minutes.
current)

Temperature coefficient V1 mA at 85 ℃ −V1 mA at 25 ℃ 1


× × 100(%/℃) 0 to ‒0.05 %/℃
of varistor voltage V1 mA at 25 ℃ 60

The change of Vc shall be measured after the specified impulse is


applied 10000 times continuously with an interval of 10 seconds at room
temperature.

Impulse life(Ⅰ) Part No. Waveform Current ΔV1 mA/V1 mA ≦±10 %


ERZVF□M220 to ERZVF□M680 8/20 μs 18A
ERZVF□M820 to ERZVF□M271 8/20 μs 50A
ERZVF□M331 to ERZVF□M471 8/20 μs 30A

The change of Vc shall be measured after the specified impulse is


applied 10000 times continuously with an interval of 10 seconds at room
temperature.

Impulse life(Ⅱ) Part No. Waveform Current ΔV1 mA/V1 mA ≦±10 %


ERZVF□M220 to ERZVF□M680 8/20 μs 12A
ERZVF□M820 to ERZVF□M271 8/20 μs 35A
ERZVF□M331 to ERZVF□M471 8/20 μs 20A

Recommendation land size

Land
8.0

Product
3.0
6.0

Occupied
5.0 Space

10.0 Unit : mm

Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
84
Matters to Be Observed When Using This Product

Matters to Be Observed When Using This Product


(E / CK / SC-type)

Safety measures
An abnormal state of E-Type, CK-type, and SC-type varistors (ZNR surge absorber, hereinafter "the product" or "the surge
absorber") that results from a problem with service conditions (materials used, the surrounding environment, power
conditions, circuit conditions, etc.) may cause a fire accident, electric shock accident, burn accident, or product failure.
Matters to note when handling this product will hereinafter be described. What is described below should be checked
sufficiently before the product is used.

■ Confirming rated capabilities


Use the surge absorber within the range of its rated capabilities. Each type of surge absorber has specified rated
capabilities including a maximum allowable circuit voltage, a surge current tolerance, an energy tolerance, an impulse
lifespan (surge lifespan), average pulse power, and a service temperature. Using the surge absorber under severe
service conditions that are beyond the rated capabilities causes degraded performance of the surge absorber or
destruction of a circuit element, which may lead to smoke generation, ignition, etc.

■ Take the following measures in order to avoid an accident caused by expected phenomenon.
(1) Destruction of the surge absorber may scatter its fractured pieces around. To protect other elements from these
pieces, set product in a case or shield it with a cover.
(2) Do not place the surge absorber near combustible materials (vinyl cable, resin mold, etc.). If avoiding the vicinity
of combustible materials is difficult, protect the combustible material with an incombustible cover.
(3) Surge absorber placed between lines
When the surge absorber is placed between lines, connect a normal type current fuse in series with the surge
absorber.
* See "Current fuse" in the "Circuit design and circuit board design" section.
(4) Surge absorber placed between a line and the ground
① When the surge absorber is placed between a line and the ground, even if the surge absorber short-circuits,
ground resistance will remain in the section between the line and the ground, leaving a possibility that the
current fuse won’t blow, in which case the outer sheath resin of the surge absorber may generate smoke or
ignite due to current flow. To prevent such a case, place an earth leakage breaker in a location closer to the
power supply than the surge absorber. When not using an earth leakage breaker, use a current fuse and
temperature fuse in series with each other.
* See Table 1 in the "Circuit design and circuit board design" section.
② When the surge absorber is placed between a live part and a metal case, it may cause electric shock if the
surge absorber short-circuits. To avoid this, ground the metal case or shield it to prevent direct contact with the
metal case.

■ In case the surge absorber should short-circuit and generate smoke or ignite, immediately cut off current flow
to the surge absorber.

■ Rated voltage for UL certification, etc.


To allow the surge absorber to meet leak current requirements, etc., a maximum allowable circuit voltage and rated
voltage are specified for the surge absorber.
When applying for UL certification, etc. of a device equipped with a surge absorber, ensure the working voltage of the
device does not exceed the rated voltage of the surge absorber.

■ An unexpected sharp rise in the working voltage, an incoming excessive surge, etc., may cause the surge absorber to
generate smoke or ignite.
In such a case, fire spreading through the device should be prevented to avoid expanded damage. To achieve this,
take a multi-protection measure, such as adopting fire-resistant materials that make up the outer shell components
and structural materials.

Use environments and cleaning conditions


■ Do not use the surge absorber in an outdoor environment where the surge absorber is exposed to sunlight.

■ Do not use the surge absorber in which direct sunlight hits the surge absorber or near a heating element where the
temperature of the surge absorber would rise above its working temperature.

■ Do not use the surge absorber in a place where the surge absorber is exposed to wind or rain or a highly humid place
where steam is emitted or dew concentrates.

■ Do not use the surge absorber in a place filled with dust or salt, in an atmosphere contaminated with a corrosive gas,
etc., or in liquids such as water, oil, chemical, or organic solvents.

30-Jun-23
85
Matters to Be Observed When Using This Product

■ Do not wash the surge absorber with a solvent (thinner, acetone, etc.) that damages the outer sheath resin.

Response to anomalies and handling conditions


Be careful not to drop the surge absorber on the floor, etc. The product is likely to suffer mechanical or electrical damage
when dropped on the floor. Avoid using such a product.

Reliability and product life


To know the detailed specifications of individual products or specific evaluation test scores, please contact us.

Circuit design and circuit board design


Meet the following requirements. Not following the requirements can result in a shorter lifespan of the surge absorber or its
failure.

■ Choose a surge absorber whose maximum allowable circuit voltage has a margin relative to the maximum voltage range
including source voltage fluctuations.
* See Table 1 in the "Circuit design and circuit board design" section.

■ When surges are applied intermittently to the surge absorber at short intervals (when pulses of voltages are applied in a
noise simulator test, etc.), make sure that the surge power does not exceed the maximum average pulse power of the surge
absorber.

■ The product numbers of recommended surge absorbers to choose are shown in Table 1.

(1) The case of placing the surge absorber between lines


When the source voltage is expected to rise temporarily due to unbalanced single-wire loads in a three-phase three-wire
connection configuration, a short circuit between a voltage line and a neutral line, loss of the neutral line, or resonance of
a capacitive load caused by switching on/off, use a surge absorber (varistor) indicated by "*" in Table 1.
(2) The case of placing the surge absorber between a line and the ground
Line-to-ground voltage may rise with a single-wire ground fault, etc. Use a recommended surge absorber in Table 1
that is different from the surge absorber placed between lines. When the device is subjected to an insulation resistance
test (500 V DC), use a surge absorber indicated by "**" in Table 1.
According to "Electrical Appliance Technical Standards" based on the Electrical Appliance and Material Safety Act, when
using a varistor voltage which would fail the insulation performance test, the surge absorber may be removed from the
device when being subjected to the test, depending on circuit test conditions.
* See attached table 4, appendix 4, "Electrical Appliance Technical Standards" based on the Electrical Appliance and
Material Safety Act.
When conducting a withstand voltage test (1000 V AC) of the device, remove the surge absorber from the device
after getting approval from the parties concerned.

■ Current fuse

(1) Select a surge absorber and fuses to use in as shown in the following table.
Confirm that no secondary accident arises when the surge absorber in an actual circuit breaks. Selected rated currents of
current fuses shown in the following table are exemplary one and may vary depending on circuit conditions used. Confirm
the rated current by a test, etc., before using the current fuse.

ERZC ERZC ERZV ERZC


Series
20EK□□□(□) 32EK□□□(□) S34C□□□ □□CK□□□W
Current fuse
(placed between lines)
10 A max. 20 A max. 20 A max. 20 A max.
Temperature fuse
(placed between a line and the 100 to 120℃ 5A 100 to 120℃ 10A 100 to 120℃ 10A 100 to 120℃ 10A
ground)

* Use the rated voltage of the current fuse that corresponds to the circuit voltage of a circuit including the current fuse.
* Connect a temperature fuse directly to the terminal so that heat from the terminal is easily transferred to the fuse and that the
fusing element of the fuse extends along its sides.

(2) Recommended parts where fuses are connected are shown in Table 1. When a load current to a protected device is so
large as to exceed the rated current of the fuse, however, connect the fuse in a location shown in the following diagram.

Current fuse
Power supply Protected
device
ZNR

30-Jun-23
86
Matters to Be Observed When Using This Product

Table 1 Application example of the product (ordinary application example)


Surge absorber placed between lines Surge absorber placed between a line and the ground

DC DC
Single-phase AC Single-phase AC
Current fuse ZNR1
Current fuse ZNR1
L
L Protected
Protected device
device N
N ZNR2

Thermal Temperature
coupling fuse
Connection

Three-phase AC Three-phase AC
Current fuse

Current fuse
ZNR3 ZNR3 ZNR3
Protected
device
Protected ZNR3
device
ZNR4
ZNR3 Temperature
Thermal
fuse
coupling

Power supply Part number Power supply Part number


ZNR voltage ZNR voltage
[AC] E, CK, SC-type [AC] E, CK, SC-type
Varistor voltage selection

100 V 201 to 361*


471
100V
511
to 220 V
821 or higher**
120 V 241 to 431*
ERZC□□EK ERZC□□EK
ZNR 1 ZNR 2
ZNR 3 ERZC□□CK ZNR 4 ERZC□□CK
200 V ERZVS34C ERZVS34C
471 to 621*
to 220 V
511
240 V
821 or higher**
240 V 511, 621*

* To find out about surge absorbers that can be used in an AC withstand voltage test,
please contact us.

Processing conditions
■ Do not apply vibration, impact (drop impact, etc.), or pressure strong enough to crack the outer sheath resin or absorber
body of the surge absorber.

■ When coating the surge absorber with a resin or embedding it in a resin mold, avoid using a resin that degrades the
surge absorber.

■ Do not bend the surge absorber or apply force thereto close to the insulation cover of the lead terminal.

■ Make the wire as short and straight as possible.

Mounting and storage conditions


■ Do not melt solder or the insulation material making up the surge absorber when soldering the lead terminal.

■ Do not keep the product in a high-temperature or high-humidity condition. Keep the surge absorber in a room with
a temperature of 40 ℃ or lower and a relative humidity of 75% or lower and use the surge absorber within two years of
storage.

■ Keep the surge absorber in a place where no corrosive gas atmosphere (hydrogen sulfide, sulfurous acid, chlorine,
ammonia, etc.) is present.

■ Keep the surge absorber in a place where the surge absorber is protected from direct sunlight, dew concentration, etc.

30-Jun-23
87
Varistors (ZNR Surge Absorber)
SC type

Varistors (ZNR Surge Absorber) Type SC protects power supply facilities,


communications equipment from steep lightning surges, and it is a suitable
product to incorporate it in a serge protective device corresponding to the
Japanese Industrial Standards (JIS C 5381-1).

Features
●Very large surge withstanding capability with a compact size
●Fast response to steep impulse voltage
●Low clamping voltage for better surge protection
●No follow-on current
●RoHS compliant

Recommended applications
●Power suppliers for OA, FA, telecommunication or industrial equipment
●Traffic or railroad systems
●Surge protection of automatic control devices for power distribution line

■ As for handling precautions and minimum quantity / Packing unit please see related information.

Explanation of part numbers

1 2 3 4 5 6 7 8 9 10 11 12

E R Z V S 3 4 C
Product code Series Shape Element size Type Nominal Design No.
varistor voltage

Ratings and characteristics


●Operating temperature range : -40 to 85 ℃ ●Storage temperature range : ‒40 to 125 ℃
Varistor Maximum Maximum Voltage Nominal Maximum
voltage allowable clamping protection discharge discharge
Part No. at 1 mA voltage voltage level current current
Acrms DC UP(V)
(V) V250 A In(8/20 μS) Imax(8/20 μS)
(V) (V) (at In)
ERZVS34C201 200(185 to 225) 130 170 340 800
ERZVS34C241 240(216 to 264) 150 200 395 900
ERZVS34C271 270(247 to 303) 175 225 455 1000
ERZVS34C361 360(324 to 396) 230 300 595 1200
ERZVS34C431 430(387 to 473) 275 350 710 1500
ERZVS34C471 470(423 to 517) 300 385 775 1500 20kA 40kA
ERZVS34C511 510(459 to 561) 320 415 845 1500
ERZVS34C621 620(558 to 682) 385 505 1025 2000
ERZVS34C751 750(675 to 825) 460 615 1240 2500
ERZVS34C821 820(738 to 902) 510 670 1355 2500
ERZVS34C951 950(855 to 1045) 575 765 1570 3000

Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
88
SC type
Typical characteristics
Voltage vs. Current (ERZVS34C201 to ERZVS34C951)

10000
Max.Leakage
Current Max.Clamping Voltage

ERZVS34C951
ERZVS34C951 ERZVS34C821
ERZVS34C751
ERZVS34C821 ERZVS34C621
ERZVS34C751 ERZVS34C511
ERZVS34C621 ERZVS34C471
ERZVS34C431
ERZVS34C511 ERZVS34C361
1000 ERZVS34C471 ERZVS34C271
ERZVS34C241
ERZVS34C201
Voltage (V)

100

ERZVS34C431
ERZVS34C361
ERZVS34C271
ERZVS34C241
ERZVS34C201

Test current waveform


10–6 to 10–3 A: Direct current
10–1 to 105 A: 8/20 μs

10
1.E-06 1.E-05 1.E-04 1.E-03 1.E-02 1.E-01 1.E+00 1.E+01 1.E+02 1.E+03 1.E+04 1.E+05

Current (A)

Dimensions in mm (not to scale)


Unit : mm
T
D
Part No. D max. H max. T max.

ERZVS34C201 9.0
Part number ZNR ERZVS34C241 9.2
ERZVS34C271 9.5
ERZVS34C361 10.4
H

Date code
ERZVS34C431 11.1
ERZVS34C471 36 47 11.3
ERZVS34C511 9.7
18 ERZVS34C621 9.7
25 ERZVS34C751 10.5
7 7 ERZVS34C821 11.0
ERZVS34C951 11.5
8

2 ø3.4

Minimum quantity / Packing unit


Minimum
Packing quantity Carton (about)
Product Series / Type Part number quantity
in carton L×W×H (mm)
/ Packing unit
“ZNR”
Transient/
SC type ERZVS34C□□□ 10 200 320×430×65
surge
absorbers
Part No., quantity and country of origin are designated on outer packages in English.
※ Please contact local sales office about packing specifications.

Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
89
Varistors (ZNR Surge Absorber)
E type

Varistors (ZNR Surge Absorber) Type E is capable of handling larger surge


energy than Type D in applications to protect electronic equipment or
semiconductor devices from switching and induced lightning surges.

Features
●UL and CSA recognized components
●Very large surge withstanding capability with a compact size
●Direct mounting on boards like a power distribution board available
●Fast response to steep impulse voltage
●Low clamping voltage for better surge protection
●RoHS compliant
Recommended applications
●Transistor, diode, IC, thyristor or triac semiconductor protection
●Surge protection in industrial power plant operations
●Relay or electromagnetic valve surge absorption
●Surge absorption applications in broadcasting, communications devices, traffic/railroad,
agricultural facilities, waterworks
●Surge protection of automatic control devices for power distribution line
Related standards
Standard No. UL1449 CSA C22.2 No.269.5
Title Surge protective devices Surge protective devices - Type 5 – Components
●Each type designation is not registered by Part Number.

Note : Ask our factory for Product Specification before use.


■ As for handling precautions and minimum quantity / Packing unit please see related information.

Explanation of part numbers


1 2 3 4 5 6 7 8 9 10 11 12

E R Z C E K
Product code Element size Type Tolerance Nominal varistor voltage Design No.

― General
Y UL/CSA Recognized

Dimensions in mm (not to scale)


ISO
24
M4
4.3

Unit : mm

L Part No. W H L
W
ERZC20EK□□□(Y) 48±1 42±1 39±1
12 ERZC32EK□□□(Y) 60±1 55±1 51±1
5

ZNR
Part No.
H

Date code

14

Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
90
E type / 20, 32 series (UL and CSA Recognized)
Ratings and characteristics (20 series)
●Operating temperature range : ‒40 to 85 ℃ ●Storage temperature range : ‒40 to 110 ℃
Maximum
Maximum Maximum peak
Varistor Maximum energy Rated
clamping current
Part No. voltage allowable (2ms) voltage
Type voltage
(UL/CSA at 1 mA voltage (8/20μs) (UL/CSA)
designation at 100 A
Recognized) 1 time 1 time
Acrms DC
(V) (V) (J) (A) ACrms (V)
(V) (V)
ERZC20EK201Y 20EK201U 200 (185 to 225) 130 170 340 80 8000 118
ERZC20EK241Y 20EK241U 240 (216 to 264) 150 200 395 95 8000 136
ERZC20EK271Y 20EK271U 270 (247 to 303) 175 225 455 100 8000 159
ERZC20EK361Y 20EK361U 360 (324 to 396) 230 300 595 120 8000 209
ERZC20EK391Y 20EK391U 390 (351 to 429) 250 320 650 130 8000 227
ERZC20EK431Y 20EK431U 430 (387 to 473) 275 350 710 140 8000 250
ERZC20EK471Y 20EK471U 470 (423 to 517) 300 385 775 150 8000 272
ERZC20EK511Y 20EK511U 510 (459 to 561) 320 415 845 150 8000 291
ERZC20EK621Y 20EK621U 620 (558 to 682) 385 505 1025 160 8000 350
ERZC20EK681Y 20EK681U 680 (612 to 748) 420 560 1120 175 8000 381
ERZC20EK751Y 20EK751U 750 (675 to 825) 460 615 1240 190 8000 418
ERZC20EK781Y 20EK781U 780 (702 to 858) 485 640 1290 200 8000 440
ERZC20EK821Y 20EK821U 820 (738 to 902) 510 670 1355 215 8000 463
ERZC20EK911Y 20EK911U 910 (819 to 1001) 550 745 1500 240 8000 500
ERZC20EK102Y 20EK102U 1000 (900 to 1100) 625 825 1650 245 8000 568
ERZC20EK112Y 20EK112U 1100 (990 to 1210) 680 895 1815 250 8000 600

Ratings and characteristics (32 series)


●Operating temperature range : ‒40 to 85 ℃ ●Storage temperature range : ‒40 to 110 ℃
Maximum
Maximum Maximum peak
Varistor Maximum energy Rated
clamping current
Part No. voltage allowable (2ms) voltage
Type voltage
(UL/CSA at 1 mA voltage (8/20μs) (UL/CSA)
designation at 200 A
Recognized) 1 time 1 time
Acrms DC
(V) (V) (J) (A) ACrms (V)
(V) (V)
ERZC32EK201Y 32EK201U 200 (185 to 225) 130 170 340 210 25000 118
ERZC32EK241Y 32EK241U 240 (216 to 264) 150 200 395 240 25000 136
ERZC32EK271Y 32EK271U 270 (247 to 303) 175 225 455 255 25000 159
ERZC32EK361Y 32EK361U 360 (324 to 396) 230 300 595 325 25000 209
ERZC32EK391Y 32EK391U 390 (351 to 429) 250 320 650 350 25000 227
ERZC32EK431Y 32EK431U 430 (387 to 473) 275 350 710 400 25000 250
ERZC32EK471Y 32EK471U 470 (423 to 517) 300 385 775 405 25000 272
ERZC32EK511Y 32EK511U 510 (459 to 561) 320 415 845 405 25000 291
ERZC32EK621Y 32EK621U 620 (558 to 682) 385 505 1025 415 25000 350
ERZC32EK681Y 32EK681U 680 (612 to 748) 420 560 1120 450 25000 381
ERZC32EK751Y 32EK751U 750 (675 to 825) 460 615 1240 500 25000 418
ERZC32EK781Y 32EK781U 780 (702 to 858) 485 640 1290 520 25000 440
ERZC32EK821Y 32EK821U 820 (738 to 902) 510 670 1355 545 25000 463
ERZC32EK911Y 32EK911U 910 (819 to 1001) 550 745 1500 600 25000 500
ERZC32EK102Y 32EK102U 1000 (900 to 1100) 625 825 1650 620 25000 568
ERZC32EK112Y 32EK112U 1100 (990 to 1210) 680 895 1815 640 25000 600

Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
91
E type / 20, 32 series
Ratings and characteristics (20 series)
●Operating temperature range : ‒40 to 85 ℃ ●Storage temperature range : ‒40 to 110 ℃

Maximum Maximum Typical


Varistor Maximum Maximum peak current
clamping Rated capacitance
voltage allowable energy
(8/20 μs)
voltage power (Reference)
Part No. at 1 mA voltage (2ms)
at 100 A at 1 kHz
1 time 2 times
Acrms DC
(V) (V) (W) (J) (A) (A) (pF)
(V) (V)
ERZC20EK201 200 (185 to 225) 130 170 340 0.8 80 8000 5000 2300
ERZC20EK241 240 (216 to 264) 150 200 395 0.8 95 8000 5000 1500
ERZC20EK271 270 (247 to 303) 175 225 455 0.8 100 8000 5000 1400
ERZC20EK361 360 (324 to 396) 230 300 595 0.8 120 8000 5000 1300
ERZC20EK391 390 (351 to 429) 250 320 650 0.8 130 8000 5000 1200
ERZC20EK431 430 (387 to 473) 275 350 710 0.8 140 8000 5000 1000
ERZC20EK471 470 (423 to 517) 300 385 775 0.8 150 8000 5000 950
ERZC20EK511 510 (459 to 561) 320 415 845 0.8 150 8000 5000 930
ERZC20EK621 620 (558 to 682) 385 505 1025 0.8 160 8000 5000 900
ERZC20EK681 680 (612 to 748) 420 560 1120 0.8 175 8000 5000 850
ERZC20EK751 750 (675 to 825) 460 615 1240 0.8 190 8000 5000 800
ERZC20EK781 780 (702 to 858) 485 640 1290 0.8 200 8000 5000 800
ERZC20EK821 820 (738 to 902) 510 670 1355 0.8 215 8000 5000 700
ERZC20EK911 910 (819 to 1001) 550 745 1500 0.8 240 8000 5000 700
ERZC20EK102 1000 (900 to 1100) 625 825 1650 0.8 245 8000 5000 400
ERZC20EK112 1100 (990 to 1210) 680 895 1815 0.8 250 8000 5000 350

Ratings and characteristics (32 series)


●Operating temperature range : ‒40 to 85 ℃ ●Storage temperature range : ‒40 to 110 ℃

Maximum Maximum Typical


Varistor Maximum Maximum
peak current
clamping Rated capacitance
voltage allowable energy
(8/20 μs)
voltage power (Reference)
Part No. at 1 mA voltage (2ms)
at 200 A at 1 kHz
1 time 2 times
Acrms DC
(V) (V) (W) (J) (A) (A) (pF)
(V) (V)
ERZC32EK201 200 (185 to 225) 130 170 340 1.2 210 25000 20000 5500
ERZC32EK241 240 (216 to 264) 150 200 395 1.2 240 25000 20000 5000
ERZC32EK271 270 (247 to 303) 175 225 455 1.2 255 25000 20000 4200
ERZC32EK361 360 (324 to 396) 230 300 595 1.2 325 25000 20000 3500
ERZC32EK391 390 (351 to 429) 250 320 650 1.2 350 25000 20000 3000
ERZC32EK431 430 (387 to 473) 275 350 710 1.2 400 25000 20000 2500
ERZC32EK471 470 (423 to 517) 300 385 775 1.2 405 25000 20000 2500
ERZC32EK511 510 (459 to 561) 320 415 845 1.2 405 25000 20000 2400
ERZC32EK621 620 (558 to 682) 385 505 1025 1.2 415 25000 20000 2200
ERZC32EK681 680 (612 to 748) 420 560 1120 1.2 450 25000 20000 2100
ERZC32EK751 750 (675 to 825) 460 615 1240 1.2 500 25000 20000 2000
ERZC32EK781 780 (702 to 858) 485 640 1290 1.2 520 25000 20000 1900
ERZC32EK821 820 (738 to 902) 510 670 1355 1.2 545 25000 20000 1800
ERZC32EK911 910 (819 to 1001) 550 745 1500 1.2 600 25000 20000 1700
ERZC32EK102 1000 (900 to 1100) 625 825 1650 1.2 620 25000 20000 1000
ERZC32EK112 1100 (990 to 1210) 680 895 1815 1.2 640 25000 20000 800

Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
92
E type / 20 series
Typical characteristics
Voltage vs. Current
(ERZC20EK201(Y) to ERZC20EK511(Y)) Max.Leakage Max.Clamping Voltage
Current
2000
ERZC20EK511(Y)
ERZC20EK471(Y)

ERZC20EK391(Y)
1000 ERZC20EK361(Y)
900
800 ERZC20EK271(Y)
700 ERZC20EK241(Y)
600 ERZC20EK201(Y)

Voltage (V)
500
400
300

200

100
90
80
70
60 Test current waveform
10–6 to 10–3 A: Direct current
50 10–1 to 104 A: 8/20 μs
40
30
10-6 10-5 10-4 10-3 10-2 10-1 100 101 102 103 104 105
Current (A)

(ERZC20EK621(Y) to ERZC20EK112(Y))
Max.Leakage Max.Clamping Voltage
4000 Current
ERZC20EK112(Y)
ERZC20EK102(Y)
3000 ERZC20EK911(Y)
ERZC20EK821(Y)
ERZC20EK781(Y)
ERZC20EK751(Y)
2000 ERZC20EK681(Y)
ERZC20EK621(Y)

1000
Voltage (V)

900
800
700
600
500
400
Test current waveform
300 10–6 to 10–3 A: Direct current
10–1 to 104 A: 8/20 μs

200
10-6 10-5 10-4 10-3 10-2 10-1 100 101 102 103 104 105
Current (A)

Impulse derating curve (Relation be tween impulse width and surge, repetitively)
(ERZC20EK201(Y) to ERZC20EK271(Y)) (ERZC20EK361(Y) to ERZC20EK681(Y)) (ERZC20EK751(Y) to ERZC20EK112(Y))
10000 10000 10000
8000 8000 8000
6000 2 times:5 min. interval 2 times:5 min. interval 6000 2 times:5 min. interval
6000
4000 up to 10 times:2 min. interval up to 10 times:2 min. interval 4000 up to 10 times:2 min. interval
4000 up to 106 times : 10 sec. interval
up to 106 times : 10 sec. interval up to 106 times : 10 sec. interval

2000 2000 2000

1000 1000 1000


800 800 800
600 600 600
400 400 400
Impulse Current(A)

Impulse Current(A)
Impulse Current(A)

200 200 200

100 100 100


80 80 80
60 60 60
40 40 40

20 20 20

10 10 10
8 8 8
6 6 6
4 4 4

2 2 2

1 1 1
20 100 1000 10000 20 100 1000 10000 20 100 1000 10000
Impulse Width(μs) Impulse Width(μs)
Impulse Width(μs)

Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
93
E type / 32 series
Typical characteristics
Voltage vs. Current
(ERZC32EK201(Y) to ERZC32EK511(Y)) Max.Leakage Max.Clamping Voltage ERZC32EK511(Y)
2000 Current ERZC32EK471(Y)
ERZC32EK431(Y)
ERZC32EK391(Y)
ERZC32EK361(Y)

1000 ERZC32EK271(Y)
900 ERZC32EK241(Y)
800
700 ERZC32EK201(Y)

600
500
400

Voltage (V)
300

200

100
90
80
70 Test current waveform
60 10–6 to 10–3 A: Direct current
50 10–1 to 104 A: 8/20 μs
40

30
10-6 10-5 10-4 10-3 10-2 10-1 100 101 102 103 104 105
Current (A)

(ERZC32EK621(Y) to ERZC32EK112(Y))
ERZC32EK112(Y)
Max.Leakage Max.Clamping Voltage ERZC32EK102(Y)
4000 Current ERZC32EK911(Y)
ERZC32EK821(Y)

3000 ERZC32EK781(Y)
ERZC32EK751(Y)
ERZC32EK681(Y)
ERZC32EK621(Y)
2000

1000
Voltage (V)

900
800
700
600
500

400 Test current waveform


10–6 to 10–3 A: Direct current
10–1 to 104 A: 8/20 μs
300

200
10-6 10-5 10-4 10-3 10-2 10-1 100 101 102 103 104 105
Current(A)

Impulse derating curve (Relation be tween impulse width and surge, repetitively)
(ERZC32EK201(Y) to ERZC32EK271(Y)) (ERZC32EK361(Y) to ERZC32EK681(Y)) (ERZC32EK751(Y) to ERZC32EK112(Y))

20000 2 times:5 min. interval 20000 2 times:5 min. interval 20000 2 times:5 min. interval
up to 10 times:2 min. interval 10000 up to 10 times:2 min. interval up to 10 times:2 min. interval
10000 10000
8000 up to 106 times : 10 sec. interval 8000 up to 106 times : 10 sec. interval 8000 up to 106 times : 10 sec. interval
6000 6000 6000
4000 4000 4000

2000 2000 2000

1000 1000 1000


800 800 800
Impulse Current(A)

600 600 600


Impulse Current(A)
Impulse Current(A)

400 400 400

200 200 200

100 100 100


80 80 80
60 60 60
40 40 40

20 20 20

10 10 10
8 8 8
6 6 6
4 4 4

2 2 2
20 100 1000 10000 20 100 1000 10000 20 100 1000 10000

Impulse Width(μs) Impulse Width(μs) Impulse Width(μs)

Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
94
E type
Performance characteristics
Characteristics Test methods / Description Specifications
Standard test Electrical measurements (initial/after tests) shall be conducted at temperature of 5 to 35

condition ℃, relative humidity of maximum 85 %.
The voltage betwen two terminals with the specified measuring current CmA DC applied
Varistor voltage is called VC or VCmA. The measurement shall be made as fast as possible to avoid heat
affection.
Maximum The maximum sinusoidal wave voltage (rms) or the maximum DC
allowable voltage voltage that can be applied continuously.
The maximum voltage between two terminals with the specified
Clamping voltage
standard impulse current (8/20 μs).
To meet the
Rated power The maximum power that can be applied within the specified ambient temperature. specified value
The maximum energy within the varistor voltage change of ±10 % when one impulse of 2
Maximum energy
ms is applied.
The maximum current within the varistor voltage change of ±10 %
Electrical

2times with the standard impulse current (8/20 μs) applied two times with an interval of 5
Maximum
minutes.
peak current
The maximum current within the varistor voltage change of ±10 %
1time
with the standard impulse current (8/20 μs) applied one time.
Temperature
Vc at 70 ℃ - Vc at 20 ℃ 1
coefficient of varistor × × 100(%/℃) 0 to ‒0.05 %/ ℃ max.
Vc at 20 ℃ 50
voltage

The change of VC shall be measured after the impulse current listed below is applied
10000 times continuously with the interval of 10 seconds at room temperature.
Impulse life ΔV1 mA/V1 mA ≦±10%
Series 20 200 A (8/20 μs)
Series 32 300 A (8/20 μs)

Withstanding voltage The commercial frequency voltage of AC 2.5 kV shall be applied between terminals and
(Body insulation) the bottom of the unit for one minute.
Robustness of After gradually applying the load of 49 N (5 kgf) and keeping the
terminations unit fixed for 10 seconds in an axial direction, the terminal shall be visually examined for
Mechanical

(Tensile) any damage. No remarkable damage


After repeadly applying a single harmonic vibration (amplitude:
0.75 mm): double amplitude: 1.5 mm with 1 minute vibration frequency cycles (10 Hz to
Vibration 55 Hz to 10 Hz) to each of three
perpendicular directions for 2 hours. Thereafter, the damage of the
terminals is visually examined.
The specimen shall be subjected to 110±3 ℃ for 500 hours
in a thermostatic bath without load and then stored at room
temperature and humidity for one to two hours. Thereafter, the change of Vc shall be
measured.
Dry heat/ High Step Temperature (℃) Period (minutes)
temperature 0 +3 ΔV1 mA/V1 mA ≦ ±5 %
storage 1 -25
-3
30
..0
2 Room Temp. 3 max.
Environmental

+3 +3
3 85
..0
30
..0
4 Room temp. 3 max.

The temperature cycle shown below shall be repeated five times and then stored at room
Temperature cycle temperature and humidity for one to two hours. The change of Vc and mechanical ΔV1 mA/V 1mA ≦ ±5 %
damage shall be examined.
After being continuously applied the Maximum Allowable Voltage
Dry heat load/
at 85±5 ℃ for 500 hours, the specimen shall be stored at room
High temperature ΔV1 mA/V1 mA ≦ ±10 %
temperature and humidity for one to two hours. Thereafter, the change of Vc shall be
load
measured.
The specimen shall be subjected to 40±2 ℃, 90 to 95 %RH for 1000 hours without load
Damp heat/Humidity
and then stored at room temperature and humidity for one to two hours. Thereafter, the ΔV1 mA/V1 mA ≦ ±5 %
(Steady state)
change of Vc shall be measured.

Minimum quantity / Packing unit


Minimum quantity Packing quantity Carton (about)
Product Series / Type Part number / Packing unit in carton L×W×H (mm)
“ZNR” General product 5 100 380×405×85
ERZC□□EK□□□
Transient/surge E type
absorbers UL and CSA recognized ERZC□□EK□□□Y 5 100 380×405×85
Part No., quantity and country of origin are designated on outer packages in English.
※ Please contact local sales office about packing specifications.

Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
95
Varistors (ZNR Surge Absorber)
CK type (UL and CSA Recognized)
Varistors (ZNR Surge Absorber) with Tabs is a heavy duty
type ZNR with very unique tab terminals which bring forth
a higher reliability. These tabs are used as electrical connecting terminals
and also its mounting legs. This type of ZNR is meant for applications in
power supplies or ransient voltage surge suppressor units where large surge
current or high surge energy absorption is required.

Features
●UL and CSA recognized components
●High energy handling capability (210 to 750 joules)
●Large withstanding peak current (20 to 25 kA, 8/20 μs, 2 times)
●Common terminals for electrical connection and mounting
●RoHS compliant

Recommended applications
●Power suppliers for OA, FA, telecommunication or industrial equipment
●Power strips
●Transient voltage surge suppressor units

Related standards
Standard No. UL1449 CSA C22.2 No.269.5
Title Surge protective devices Surge protective devices - Type 5 – Components

●Each type designation is not registered by Part Number.


Please contact us for further questions regarding type designation.

Note : Ask our factory for Product Specification before use.

■ As for handling precautions and minimum quantity / Packing unit please see related information.

Explanation of part numbers


A

1 2 3 4 5 6 7 8 9 10 11 12

E R Z C C K
Product code Series Element size Type Tolerance Nominal Design No.
varistor voltage

Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
96
CK type
Ratings and characteristics
●Operating temperature range : -40 to 85 ℃ ●Operating temperature range : ‒40 to 125 ℃
Varistor Maximum Maximum
Maximum Maximum
Part No. voltage energy peak current
Type allowable clamping
(UL/CSA (2ms) (8/20 μs)
designation at 1mA voltage voltage
Rrecognized) 1 time 1 time 2 times
(V) AC rms(V) DC (V) VXA (V) Ip (A) (J) (kA) (kA)
ERZC32CK201W 32K201U 200 (185 to 225) 130 170 340 200 210 25 20
ERZC32CK241W 32K241U 240 (216 to 264) 150 200 395 200 240 25 20
ERZC32CK271W 32K271U 270 (247 to 303) 175 225 455 200 255 25 20
ERZC32CK361W 32K361U 360 (324 to 396) 230 300 595 200 325 25 20
ERZC32CK391W 32K391U 390 (351 to 429) 250 320 650 200 350 25 20
ERZC32CK431W 32K431U 430 (387 to 473) 275 350 710 200 400 25 20
ERZC32CK471W 32K471U 470 (423 to 517) 300 385 775 200 405 25 20
ERZC32CK511W 32K511U 510 (459 to 561) 320 415 845 200 405 25 20
ERZC32CK621W 32K621U 620 (558 to 682) 385 505 1025 200 415 25 20
ERZC32CK681W 32K681U 680 (612 to 748) 420 560 1120 200 450 25 20
ERZC32CK751W 32K751U 750 (675 to 825) 460 615 1240 200 500 25 20
ERZC32CK781W 32K781U 780 (702 to 858) 485 640 1290 200 520 25 20
ERZC32CK821W 32K821U 820 (738 to 902) 510 670 1355 200 545 25 20
ERZC32CK911W 32K911U 910 (819 to 1001) 550 745 1500 200 600 25 20
ERZC32CK951W 32K951U 950 (855 to 1045) 575 765 1570 200 600 25 20
ERZC40CK201W 40K201U 200 (185 to 225) 130 170 340 250 260 30 25
ERZC40CK241W 40K241U 240 (216 to 264) 150 200 395 250 300 30 25
ERZC40CK271W 40K271U 270 (247 to 303) 175 225 455 250 340 30 25
ERZC40CK361W 40K361U 360 (324 to 396) 230 300 595 250 405 30 25
ERZC40CK391W 40K391U 390 (351 to 429) 250 320 650 250 435 30 25
ERZC40CK431W 40K431U 430 (387 to 473) 275 350 710 250 500 30 25
ERZC40CK471W 40K471U 470 (423 to 517) 300 385 775 250 505 30 25
ERZC40CK511W 40K511U 510 (459 to 561) 320 415 845 250 505 30 25
ERZC40CK621W 40K621U 620 (558 to 682) 385 505 1025 250 515 30 25
ERZC40CK681W 40K681U 680 (612 to 748) 420 560 1120 250 560 30 25
ERZC40CK751W 40K751U 750 (675 to 825) 460 615 1240 250 625 30 25
ERZC40CK781W 40K781U 780 (702 to 858) 485 640 1290 250 650 30 25
ERZC40CK821W 40K821U 820 (738 to 902) 510 670 1355 250 680 30 25
ERZC40CK911W 40K911U 910 (819 to 1001) 550 745 1500 250 750 30 25
ERZC40CK951W 40K951U 950 (855 to 1045) 575 765 1570 250 750 30 25

Dimensions (not to scale)


Unit : mm Part No.
Type designation D max. H max. T max. d
(UL/CSA recognized)

ERZC32CK201W 32K201U 7.5 5.7±1.0


・ZNR ERZC32CK241W 32K241U 7.5 5.4±1.0
・Abbreviation of Part No. ERZC32CK271W 32K271U 8.5 5.2±1.0
ERZC32CK361W 32K361U 9.0 4.6±1.0
・Date code Af
ERZC32CK391W 32K391U 9.0 4.4±1.0
te
ERZC32CK431W 32K431U 9.0 4.1±1.0
T ERZC32CK471W 32K471U 9.7 3.9±1.0
ERZC32CK511W 32K511U 36 46 9.7 4.5±1.0
ERZC32CK621W 32K621U 9.7 3.9±1.0
ERZC32CK681W 32K681U 9.7 3.6±1.0
H ERZC32CK751W 32K751U 10.5 3.3±1.0
ERZC32CK781W 32K781U 10.5 3.1±1.0
ERZC32CK821W 32K821U 10.5 2.9±1.0
ERZC32CK911W 32K911U 11.5 2.5±1.0
ERZC32CK951W 32K951U 11.5 2.3±1.0
ERZC40CK201W 40K201U 7.5 5.7±1.0
18 ERZC40CK241W 40K241U 7.5 5.4±1.0
25 ERZC40CK271W 40K271U 8.5 5.2±1.0
ERZC40CK361W 40K361U 9.0 4.6±1.0
ERZC40CK391W 40K391U 9.0 4.4±1.0
7 7 ERZC40CK431W 40K431U 9.0 4.1±1.0
ERZC40CK471W 40K471U 9.7 3.9±1.0
d 8 ERZC40CK511W 40K511U 44 50 9.7 4.5±1.0
ERZC40CK621W 40K621U 9.7 3.9±1.0
2 ø3.4 ERZC40CK681W 40K681U 9.7 3.6±1.0
ERZC40CK751W 40K751U 10.5 3.3±1.0
ERZC40CK781W 40K781U 10.5 3.1±1.0
ERZC40CK821W 40K821U 10.5 2.9±1.0
ERZC40CK911W 40K911U 11.5 2.5±1.0
ERZC40CK951W 40K951U 11.5 2.3±1.0

Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
97
CK type
Typical characteristics
Voltage vs. Current

(ERZC32CK201W to ERZC32CK951W)
6000
Max.Leakage
Current
4000 ERZC32CK951W
Max.Clamping Voltage
ERZC32CK911W
ERZC32CK821W
ERZC32CK951W
ERZC32CK751W
ERZC32CK911W
ERZC32CK681W
ERZC32CK821W ERZC32CK621W
ERZC32CK751W ERZC32CK511W
2000
ERZC32CK681W ERZC32CK471W
ERZC32CK621W ERZC32CK431W
ERZC32CK391W
ERZC32CK511W
ERZC32CK361W
ERZC32CK471W
ERZC32CK431W
1000 ERZC32CK391W ERZC32CK271W
Voltage(V)

ERZC32CK361W ERZC32CK241W
800
ERZC32CK201W

600

400

200

100

ERZC32CK271W Test current waveform


80 ERZC32CK241W 10–6 to 10–3 A: Direct current
ERZC32CK201W 10–1 to 104 A: 8/20 μs
60

10-6 10-5 10-4 10-3 10-2 10-1 100 101 102 103 104 105

Current(A)

(ERZC40CK201W to ERZC40CK951W)

6000
Max.Leakage
Current
4000 Max.Clamping Voltage
ERZC40CK951W
ERZC40CK951W ERZC40CK911W
ERZC40CK911W ERZC40CK821W
ERZC40CK821W ERZC40CK751W
ERZC40CK751W ERZC40CK681W
2000 ERZC40CK681W ERZC40CK621W
ERZC40CK621W ERZC40CK511W
ERZC40CK471W
ERZC40CK511W ERZC40CK431W
ERZC40CK471W ERZC40CK391W
ERZC40CK431W
ERZC40CK391W ERZC40CK361W
1000
ERZC40CK361W
ERZC40CK271W
800
ERZC40CK241W
ERZC40CK201W
Voltage(V)

600

400

200 A

100
Test current waveform
ERZC40CK271W 10–6 to 10–3 A: Direct current
80
ERZC40CK241W 10–1 to 104 A: 8/20 μs
ERZC40CK201W
60

10-6 10-5 10-4 10-3 10-2 10-1 100 101 102 103 104 105

Current(A)

Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
98
CK type
Application note for safety standards
● Approvals products lists in "Reference Guide to Standard Products."
● UL and VDE : Registered in "Type name", it isn’t registered in "Panasonic Part No."
● CQC : Registered in "Panasonic Part No."
● "Rated Voltages" are specified for UL recognized components in list shown below.

The AC rated voltage and maximum allowable voltage


Part No. Maximum allowable voltage Rated voltage (Vrms)

(UL/CSA recognized) AC rms (V) DC (V) UL1449 CSA C22.2 No.269.5


ERZC32CK201W 130 170 118 118
ERZC32CK241W 150 200 136 136
ERZC32CK271W 175 225 159 159
ERZC32CK361W 230 300 209 209
ERZC32CK391W 250 320 227 227
ERZC32CK431W 275 350 250 250
ERZC32CK471W 300 385 272 272
ERZC32CK511W 320 415 291 291
ERZC32CK621W 385 505 350 350
ERZC32CK681W 420 560 381 381
ERZC32CK751W 460 615 418 418
ERZC32CK781W 485 640 440 440
ERZC32CK821W 510 670 463 463
ERZC32CK911W 550 745 500 500
ERZC32CK951W 575 765 522 522
ERZC40CK201W 130 170 118 118
ERZC40CK241W 150 200 136 136
ERZC40CK271W 175 225 159 159
ERZC40CK361W 230 300 209 209
ERZC40CK391W 250 320 227 227
ERZC40CK431W 275 350 250 250
ERZC40CK471W 300 385 272 272
ERZC40CK511W 320 415 291 291
ERZC40CK621W 385 505 350 350
ERZC40CK681W 420 560 381 381
ERZC40CK751W 460 615 418 418
ERZC40CK781W 485 640 440 440
ERZC40CK821W 510 670 463 463
ERZC40CK911W 550 745 500 500
ERZC40CK951W 575 765 522 522

Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
99
CK type
Performance characteristics
Characteristics Test methods/description Specifications
Electrical measurements (initial/after tests) shall be conducted at temperature of 5 to
Standard test condition ―
35 ℃, relative humidity of maximum 85 %.
The voltage betwen two terminals with the specified measuring current 1mA DC
Varistor voltage applied is called V1 or V1mA. The measurement shall be made as fast as possible to
avoid heat affection.
Maximum The maximum sinusoidal wave voltage (rms) or the maximum DC
allowable voltage voltage that can be applied continuously.
The maximum voltage between two terminals with the specified
Clamping voltage
Electrical

standard impulse current (8/20 μs).


To meet the
Rated power The maximum power that can be applied within the specified ambient temperature. specified value

The maximum energy within the varistor voltage change of ±10 % when one impulse of
Maximum energy
2 ms is applied.
The maximum current within the varistor voltage change of ±10 %

with the standard impulse current (8/20 μs) applied two times with an interval of 5
Maximum times minutes
peak current The maximum current within the varistor voltage change of ±10 %
1time
with the standard impulse current (8/20 μs) applied one time.
Robustness of
After gradually applying the load of 19.6 N (2 kgf) and keeping the No remarkable
terminations
unit fixed for 10 seconds, the terminal shall be visually examined for any damage. damage
(Tensile)
After repeadly applying a single harmonic vibration (amplitude:
0.35 mm): double amplitude: 0.7 mm with 1 minute vibration frequency cycles (10 Hz No remarkable
Vibration
to 55 Hz to 10 Hz) to each of three damage
Mechanical

perpendicular directions for 2 hours. Thereafter, the unit shall be visually examined.

Approximately 95 %
After dipping the terminal to a depth of approximately 3 mm from
of the terminals shall
Solderability the body in a soldering bath of 230±5 ℃ for 5.0±0.5 seconds, the terminal shall be
be covered with new solder
visually examined.
uniformly.
The terminal shall be dipped into a soldering bath having a
Resistance to temperature of 350±10 ℃ to a point 4.0±0.8 mm from the body
ΔV1 mA/V1 mA ≦ ±5 %
soldering heat of the unit and then be held there for 3.0±0.5 seconds. The change of Vc and
mechanical damage shall be examined.
The specimen shall be subjected to 125±2 ℃ for 500 hours
Dry heat/ high
in a thermostatic bath without load and then stored at room
temperature
temperature and humidity for one to two hours. Thereafter, the change of Vc shall be
storage
measured. ΔV1 mA/V1 mA ≦ ±5 %
The specimen shall be subjected to 40±2 ℃, 90 to 95 %RH for 1000 hours without
Damp heat/humidity
load and then stored at room temperature and humidity for one to two hours.
(Steady State)
Thereafter, the change of Vc shall be measured.
The temperature cycle shown below shall be repeated five times and then stored at
room temperature and humidity for one to two hours. The change of Vc and
Environmental

mechanical damage shall be examined.


Step Temperature (℃) Period (minutes)
+3 ΔV1 mA/V1 mA ≦ ±5 %
1 –25±3 30
Temperature cycle ..0 No remarkable
2 Room Temp. 3 max. damage
+3
3 85±2 30
..0
4 Room Temp. 3 max.

After being continuously applied the Maximum Allowable Voltage


Dry heat load/
at 85±2 ℃ for 500 hours, the specimen shall be stored at room
high temperature ΔV1 mA/V1 mA ≦ ±10 %
temperature and humidity for one to two hours. Thereafter, the change of Vc shall be
load
measured.

Minimum quantity / Packing unit


Minimum quantity Packing quantity in Carton (about)
Product Series / Type Part number / Packing unit carton L×W×H (mm)
“ZNR”
UL and
Transient/surge CK type ERZC□□CK□□□W 10 200 320×430×65
CSA recognized
absorbers

Part No., quantity and country of origin are designated on outer packages in English.
※ Please contact local sales office about packing specifications.

Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
100
Matters to Be Observed When Using This Product

Matters to Be Observed When Using This Product


(P, J, G-type / Arrestor box / E, J-type for thyristor)

Safety measures
An abnormal state for varistors (ZNR surge absorbers) of P-type, J-type, G-type, an arrestor box, and varistors for thyristors
(hereinafter "the product" or "the surge absorber") that results from a problem with service conditions (materials used, the
surrounding environment, power conditions, circuit conditions, etc.) may cause a fire accident, electric shock accident, burn
accident, or product failure. Matters to note when handling this product will hereinafter be described. What is described
below should be checked sufficiently before the product is used.

■ Confirming rated capabilities


Use the surge absorber within the range of its rated capabilities. Each type of surge absorber has specified rated
capabilities including a maximum allowable circuit voltage, a surge current tolerance, an energy tolerance, an impulse
lifespan (surge lifespan), average pulse power, and a service temperature. Using the surge absorber under severe
service conditions that are beyond the rated capabilities causes degraded performance of the surge absorber or
destruction of a circuit element, which may lead to smoke generation, ignition, etc.

■ Take the following measures in order to avoid an accident caused by expected phenomenon.

(1) Destruction of the surge absorber may scatter its fractured pieces around. To protect other elements from these
pieces, set product in a case or shield it with a cover.
(2) Do not place the surge absorber near combustible materials (vinyl cable, resin mold, etc.). If avoiding the vicinity
of combustible materials is difficult, protect the combustible material with an incombustible cover.
(3) Surge absorber placed between lines
① When the surge absorber is placed between lines, connect a normal type current fuse in series with the surge
absorber.
② The P-type surge absorber has a built-in temperature fuse but its breaking capacity is low (0.3 A). For this
reason, a current fuse needs to be connected in series with the surge absorber.
(4) Surge absorber placed between a line and the ground
① When the surge absorber is placed between a line and the ground, even if the surge absorber short-circuits,
ground resistance will remain in the section between the line and the ground, leaving a possibility that the
current fuse won’t blow, in which case the outer sheath resin of the surge absorber may generate smoke or
ignite due to current flow. To prevent such a case, place an earth leakage breaker in a location closer to the
power supply than the surge absorber. When not using an earth leakage breaker, use a current fuse and
temperature fuse in series with each other.
* See Table 1 in the "Circuit design and circuit board design" section.
② When the surge absorber is placed between a live part and a metal case, it may cause electric shock if the
surge absorber short-circuits. To avoid this, ground the metal case or shield it to prevent direct contact with the
metal case.

■ Do not touch a live part of the surge absorber. You may get an electric shock when touching it. In case the surge
absorber should short-circuit and generate smoke or ignite, immediately cut off current flow to the surge absorber.

■ An unexpected sharp rise in the working voltage, an incoming excessive surge, etc., may cause the surge absorber to
generate smoke or ignite.
In such a case, fire spreading through the device should be prevented to avoid expanded damage. To achieve this,
take a multi-protection measure, such as adopting fire-resistant materials that make up the outer shell components
and structural materials.

Use environments and cleaning conditions


■ Do not use the surge absorber in an outdoor environment where the surge absorber is exposed to sunlight.

■ Do not use the surge absorber in which direct sunlight hits the surge absorber or near a heating element where the
temperature of the surge absorber would rise above its working temperature.

■ Do not use the surge absorber in a place where the surge absorber is exposed to wind or rain or a highly humid place
where steam is emitted or dew concentrates.

■ Do not use the surge absorber in a place filled with dust or salt, in an atmosphere contaminated with a corrosive gas,
etc., or in liquids such as water, oil, chemical, or organic solvents.

■ Do not wash the surge absorber with a solvent (thinner, acetone, etc.) that damages the outer sheath resin.

30-Jun-23
101
Matters to Be Observed When Using This Product

Response to anomalies and handling conditions


Be careful not to drop the surge absorber on the floor, etc. The product is likely to suffer mechanical or electrical damage
when dropped on the floor. Avoid using such a product.

Reliability and product life


■ To know the detailed specifications of individual products or specific evaluation test scores, please contact us.

■ We recommend you to carry out a maintenance check of the varistor to measure its varistor voltage once every two years.
The varistor should be replaced when a difference between the current varistor voltage (1 mA V) and the initial varistor
voltage exceeds ±10%.

Circuit design and circuit board design


Meet the following requirements. Not following the requirements can result in a shorter lifespan of the surge absorber or its
failure.

■ Choose a surge absorber whose maximum allowable circuit voltage has a margin relative to the maximum voltage range
including source voltage fluctuations.

■ When surges are applied intermittently to the surge absorber at short intervals (when pulses of voltages are applied in a
noise simulator test, etc.), make sure that the surge power does not exceed the maximum average pulse power of the
surge absorber.

■ Use an arrestor box with the specified power distribution layout.

Processing conditions
■ Do not apply vibration, impact (drop impact, etc.), or pressure strong enough to crack the outer sheath resin or absorber
body of the surge absorber.

■ When coating the surge absorber with a resin or embedding it in a resin mold, avoid using a resin that degrades the
surge absorber.

■ Do not bend the surge absorber or apply force thereto close to the insulation cover of the lead terminal.

■ Make the wire as short and straight as possible.

Mounting and storage conditions


■ Do not melt solder or the insulation material making up the surge absorber when soldering the lead terminal.

■ Do not keep the product in a high-temperature or high-humidity condition. Keep the surge absorber in a room with
a temperature of 40 ℃ or lower and a relative humidity of 75% or lower and use the surge absorber within two years of
storage.

■ Keep the surge absorber in a place where no corrosive gas atmosphere (hydrogen sulfide, sulfurous acid, chlorine,
ammonia, etc.) is present.

■ Keep the surge absorber in a place where the surge absorber is protected from direct sunlight, dew concentration, etc.

30-Jun-23
102
Varistors (ZNR Surge Absorber)
P type

Varistors (ZNR Surge Absorber), Type P is a suitable device to protect


various electric equipment and semiconductive devices from
instantaneous over-voltages like switching surges and induced
lightnings. The Type P is characterized by the unique construction of
plug-in type with a deterioration indicator.

Features
●RoHS compliant

Recommended applications
Protection of semiconductor devices used for the electronic equipment includes:
●Broadcasting, communication equipment
●Traffic or railroad systems
●Automatic control devices for power distribution
●Waterworks
●Protection of motor coils, vacuum switches

Note : Ask our factory for product specification before use.

■ As for handling precautions and minimum quantity / Packing unit please see related information.

Explanation of part numbers

1 2 3 4 5 6 7 8 9 10 11 12

E R Z A P K
Product code Series Element size Type Tolerance Nominal Design No.
varistor voltage

Ratings and characteristics


●Operating temperature range : -25 to 70 ℃ ●Storage temperature range : ‒25 to 70 ℃

Varistor Maximum Typical


Maximum Maximum Maximum
voltage clamping capacitance
allowable peak current energy
Part No. voltage (Reference)
at 1 mA voltage (8/20 μs, 2 times) (2 ms, 1 time)
at 100A at 1 kHz
(V) ACrms(V) DC (V) (V) (A) (J) (pF)
ERZA20PK251 250±10 % 130 180 410 5000 90 1200
ERZA20PK501 500±10 % 260 360 825 5000 150 600
ERZA20PK102 1000±10 % 520 730 1650 5000 240 300

Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
103
P type
Typical characteristics
Voltage vs. Current (ERA20PK251 to ERZA20PK102)

Max.Leakage
4000 Current Max.Clamping Voltage

3000

2000

1000
900
800
700
Voltage (V)

600
500
400

300

200

100
90 Test current waveform
80 10–6 to 10–3 A: Direct current
70 10–1 to 104 A: 8/20 μs
60

10-6 10-5 10-4 10-3 10-2 10-1 1 10 102 103 104 105

Current (A)

Dimensions in mm (not to scale)

47
3
7
ø30
Mounting pitch

NP
66

16

78
88
φ9

Mounting hole
ø4.5

M4

Life indicator

Unit : mm

Minimum quantity / Packing unit


Minimum quantity Packing quantity in Carton (about)
Product Series / Type Part number / Packing unit carton L×W×H (mm)
“ZNR”
Transient/surge P type ERZA20PK□□□ 1 40 380×405×75
absorbers

Part No., quantity and country of origin are designated on outer packages in English.
※ Please contact local sales office about packing specifications.

Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
104
Varistors (ZNR Surge Absorber)
J type

Varistors (ZNR Surge Absorber), Type J, are designed especially for surge
protection of industrial equipment from high energy transient voltages which are
generated by switching of the inductive loads such as DC magnet relays or
transformers.

Features
●Low clamping voltage
●Fast response to steep impulse voltage
●A bilateral and symmetrical V-I characteristic curve
●Higher energy handling capability (5000 to 44000 J)
●No follow-on current
●Wide product range [Varistor Voltage] 500 V to 1300 V
●RoHS compliant

Recommended applications
●Suppression of volume surges such as those produced by switching of DC lifting magnets and
within equipment in railroad vehicles
●Protection of a current transformer from overheating caused with secondary opening
●Protection of thyristors or diodes employed in power supply equipment

Note : Ask our factory for product specification before use.

■ As for handling precautions and minimum quantity / Packing unit please see related information.

Explanation of part numbers

1 2 3 4 5 6 7 8 9 10 11 12

E R Z A J K
Product code Series Element size Type Tolerance Nominal Design No.
varistor voltage

Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
105
J type
Ratings and characteristics
●Operating temperature range : -25 to 70 ℃ ●Storage temperature range : ‒25 to 110 ℃

Maximum Typical
Varistor Maximum Maximum
clamping Maximum capacitance
voltage allowable peak current
Part No. voltage energy (Reference)
at 1mA voltage (4/10 μs, 2 times)
at 100A at 1 kHz
(V) ACrms (V) DC (V) (V) (J) (kA) (pF)
ERZA80JK561 5000 80 9800

ERZA80JK561A 560 10000 80 ×2 19600


250 350 925
ERZA80JK561B (505 to 615) 15000 80 ×3 29400

ERZA80JK561C 20000 80 ×4 39200

ERZA80JK112 10000 80 4800

ERZA80JK112A 1100 20000 80 ×2 9600


485 680 1800
ERZA80JK112B (980 to 1200) 30000 80 ×3 14400

ERZA80JK112C 40000 80 ×4 19200

ERZA80JK122 11000 80 4400

ERZA80JK122A 1250 22000 80 ×2 8800


550 775 2070
ERZA80JK122B (1120 to 1380) 33000 80 ×3 13200

ERZA80JK122C 44000 80 ×4 17600

Typical characteristics
Voltage vs. Current Impulse Derating (Relation between
impulse width and impulse current multiple)
106
Max.Leakage
Current
Max.Clamping Voltage
5,000
105
1.0
3,000 (100 μs
0 T
to 1s)
2,000
Voltage(V)

104
1.0
0.5
Impulse Current(A)

1,000 0 T
103 (10 to 40 μs)
700

500
102
300
Test current waveform
200 10–6 to 10–3 A: Direct current
10–1 to 104 A: 8/20 μs 10

100
10-6 10-5 10-4 10-3 10-2 10-1 100 101 102 103 104 105
1

Current(A)
0.1

0.01
10 μs 100 μs 1 ms 10 ms 100 ms 1s

Impulse Width

Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
106
J type
Dimensions in mm (not to scale)
ERZA80JK□□□ ERZA80JK□□□B

M6 A 5.5 mm2 Terminal Name plate


M6 A 5.5 mm2 Terminal Name plate 96±0.2
7±1.0
7±1.0 96±0.2

7±1.0
7±1.0
Terminal Terminal
Terminal Terminal

□110

□110
140
140

85
85

Hole Bar Hole


Bar
B
B 8.5 8.5
C
C

39
26
39
26

3 18
3 18

ZNR connection ZNR connection

40±0.4 40±0.4
62 62

ERZA80JK□□□A ERZA80JK□□□C

M6 A 5.5 mm2 Terminal Name plate M6 A 5.5 mm2 Terminal Name plate
7±1.0 96±0.2 7±1.0 96±0.2

7±1.0
7±1.0

Terminal Terminal Terminal Terminal

□110
□110
140

140
85

85
Bar Hole Bar Hole
B B
8.5 8.5
C C

ZNR connection

39
39
26

ZNR connection

26
3 18

3 18

40±0.4 40±0.4
62 62

Unit : mm

Part No. A B C
ERZA80JK561 14.0 125.0±4.0 161.0±4.0
ERZA80JK561A 14.0 138.0±8.0 174.0±8.0
ERZA80JK561B 40.0 151.0±8.0 187.0±8.0
ERZA80JK561C 40.0 164.0±8.0 200.0±8.0
ERZA80JK112 19.0 130.0±4.0 166.0±4.0
ERZA80JK112A 19.0 148.0±8.0 184.0±8.0
ERZA80JK112B 56.0 167.0±8.0 203.0±8.0
ERZA80JK112C 56.0 185.0±8.0 221.0±8.0
ERZA80JK122 21.0 132.0±4.0 168.0±4.0
ERZA80JK122A 21.0 152.0±8.0 188.0±8.0
ERZA80JK122B 61.0 172.0±8.0 208.0±8.0
ERZA80JK122C 61.0 192.0±8.0 228.0±8.0

Minimum quantity / Packing unit


Minimum quantity Packing quantity in Carton (about)
Product Series / Type Part number / Packing unit carton L×W×H (mm)
“ZNR”
Transient/surge J type ERZA80JK□□□ 1 3 220×280×195
absorbers

Part No., quantity and country of origin are designated on outer packages in English.
※ Please contact local sales office about packing specifications.

Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20

107
Varistors (ZNR Surge Absorber)
G type

High energy transient over voltages generated by switching on/off of a vacuum relay in
power distribution line can cause insulation breakdown of high voltage electronic
equipment/devices and power cables etc…
Varistors (ZNR Surge Absorber), Type G are gapless type arresters using sintered bodies
of zinc-oxide and are characterized by the excellent characteristics of high energy handling
capability, fast response time and low clamp ratio etc... The ZNR and G have wide
applications for protection of high-voltage motors, tranformers, rectifiers and anticorrosion
layers of powercables from high energy transient overvoltages/surges.

Features
●RoHS compliant

Recommended applications
●Protection of high voltage motors, transformers or rectifiers from switching surges
●Switching surge absorption in vacuum circuit interrupters
●Protection of anti-corrosion layer of under ground electric power cable from induced lightning or switching surges
Note : Ask our factory for Product Specification before use.
■ As for handling precautions and minimum quantity / Packing unit please see related information.

Ratings and characteristics


●Operating temperature range : -25 to 70 ℃ ●Storage temperature range : ‒40 to 85 ℃
Part No.
Characteristics
ERZA20GS852H ERZA20GS173H
Connection AC 3.3 kV Line-Ground AC 6.6 kV Line-Ground
+0.75 +1.50
Varistor voltage (V1 mA) 8.50 kV 17.0 kV
−0.50 −1.0
Maximum clamping voltage
12.75 kV 25.5 kV
@100 A (8/20 µs)
Maximum peak current
5000 A 5000 A
(8/20 µs, 2 times )
Maximum allowable voltage AC 3.45 kV AC 6.9 kV
Impulse life (2 ms, 104 times ) 20 A 20 A
Maximum allowable energy 1300 J 2600 J

Dimensions in mm (not to scale)


ERZA20GS852H ERZA20GS173H

M10 Bolt M10 Bolt


Terminal 5.5 mm2 Terminal 5.5 mm2

Mounting hole
2-ø8.5
105
160

Mounting hole
145
200

2-ø8.5
22

N.P
28

80 10 16
22

N.P
Mounting pitch
28

16
20.0±0.5 100 10
Mounting pitch
ø54 Unit : mm
20.0±0.5
ø54

Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
108
G type
Ratings and characteristics
●Operating temperature range : 0 to 50 ℃ ●Storage temperature range : ‒10 to 70 ℃

Part No.
ERZA48GK502
Characteristics
Across the
Connection
Anti-corrosion layers
Varistor voltage (V1 mA) 5.0 kV±0.5 kV
Maximum clamping voltage
14 kV at V23 kA
(8/20 µs)
Maximum peak current
21 kA at 100 times
(8/20 µs )

Dimensions in mm (not to scale)

ERZA48GK502

15 85 15

ø14
32

22

33 49 33 ø70

Unit : mm

Minimum quantity / Packing unit


Minimum quantity Packing quantity Carton (about)
Product Series / Type Part number / Packing unit in carton L×W×H (mm)
“ZNR”
Transient/surge G type ERZA□□GK□□□ 1 3 220×280×195
absorbers

Part No., quantity and country of origin are designated on outer packages in English.
※ Please contact local sales office about packing specifications.

Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
109
Varistors (ZNR Surge Absorber)
Surge absorber units

The Surge Absorber Unit contains Y, Δ or p connected ZNRs surge absorbers (and, if necessary, a circuit
breaker) in a box.
These Surge Absorber Units are designed for surge protection of industrial electric equipment where
reliability is essential.

Recommended applications

Surge Protection of
● Railway/traffi c signal control systems
● Distribution line control systems
● Broadcasting systems, communication systems
● Measuring instruments
● Controllers of low voltage distribution line
● Controllers of waterworks

Note : Ask our factory for Product Specification before use.

■ As for handling precautions and minimum quantity / Packing unit please see related information.

Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
hould a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
110
Surge absorber units
ZNR Surge absorber units
Maximum
Rated
Application peak Part No. Dimensions Connection
voltage
current

DC 12 V ERZA5F220AC Coil: 1 mH max.


Max. continuous current: 0.6 A
DC 24 V ERZA5F390AC
For signal system

Equipmen
(Line to line and Line 5000 A DC 48 V ERZA5F680AC D
to ground use)
DC 80 V ERZA5F101AC

DC 100 V ERZA5F201ACA
Type D (other : Type E)
DC 12 V ERZA5F220BC Coil: 1 mH max.
Max. continuous current: 0.6 A
DC 24 V ERZA5F390BC
For signal system

Equipmen
(Line to line use 5000 A DC 48 V ERZA5F680BC D
only)
DC 80 V ERZA5F101BC

DC 100 V ERZA5F201BC
Type D (other : Type E)

Dimensions in mm (not to scale)

3-ø6
Mounting pitc

160
135

Mounting pitch

85
83

(D)

105 Unit:mm

Minimum quantity / Packing unit


Minimum quantity Packing quantity Carton (about)
Product Series / Type Part number / Packing unit in carton L×W×H (mm)
“ZNR”
Transient/surge Surge absorber units ERZA□□□□□□□ 1 ― 275×345×145
absorbers

Part No., quantity and country of origin are designated on outer packages in English.
※ Please contact local sales office about packing specifications.

Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
hould a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
111
Varistors (ZNR Surge Absorber)
For thyristor protection
E type
J type

Varistors (ZNR Surge Absorber) for thyristors is especially designed to


protect Thyristor power controllers and Thyristor power sources from
high energy transient over voltages.
The ZNR is smaller in size and excellent in the clamping voltage
characteristics as compared with a conventional selenium surge
absorber.
Type E is for relatively low handling capacity of trans-former and Type J
is for heavy duty use.

Features
● RoHS compliant

Recommended applications
● Surge protection of thyristor power controllers
● Surge protection of thyristor power sources

Note : Ask our factory for product specification before use.

■ As for handling precautions and minimum quantity / Packing unit please see related information.

Ratings and characteristics (E type)


●Operating temperature range : ‒40 to 85 ℃ ●Storage temperature range : ‒40 to 110 ℃

Varistor Maximum Maximum


Impulse life
voltage allowable clamping Commutation
Part No. (2 ms, 104 times)
at 1 mA voltage voltage surge ratio
(V) ACrms(V) DC (V) Vlp (V) lp (A) (A)
ERZC20EK511P 498 to 542 242 342 760 1.45
ERZC20EK541P 523 to 560 264 373 785 1.40
ERZC20EK681P 630 to 678 330 467 950 1.35
ERZC20EK821P 788 to 848 412 583 1185 10 10 1.35
ERZC20EK911P 840 to 904 440 622 1265 1.35
ERZC20EK102P 945 to 1017 495 700 1425 1.35
ERZC20EK112P 1051 to 1181 550 775 1655 1.35
ERZC32EK511P 498 to 542 242 342 760 1.45
ERZC32EK541P 523 to 560 264 373 785 1.40
ERZC32EK681P 630 to 678 330 467 950 1.35
ERZC32EK821P 788 to 848 412 583 1185 20 20 1.35
ERZC32EK911P 840 to 904 440 622 1265 1.35
ERZC32EK102P 945 to 1017 495 700 1425 1.35
ERZC32EK112P 1051 to 1181 550 775 1655 1.35

Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
112
For thyristor protection / E, J type
Dimensions in mm (not to scale) (E type)

ISO
24 M4

4.3
L
W

12

5
ZNR Dot
H

Part No.

Date code

14

Unit : mm

Part No. W H L
ERZC20EK□□□P 48±1 42±1 39±1
ERZC32EK□□□P 60±1 55±1 51±1

Ratings and characteristics (J type)


●Operating temperature range : ‒40 to 70 ℃ ●Storage temperature range : ‒40 to 110 ℃

Maximum allowable Maximum clamping Impulse life


Dimensions in mm
Part No. Connection voltage voltage (2 ms, 104 times) Commutation
surge ratio
ACrms (V) DC (V) Vlp (V) lp (A) (A) Style A B C
ERZU11JP511 40 40 88 108
ERZU12JP511 70 70 104 124
ERZU13JP511 95 95 121 141
ERZU14JP511 Single 242 342 760 125 125 1.45 (1) 138 158 20
ERZU15JP511 150 150 155 175
ERZU16JP511 180 180 172 192
ERZU17JP511 210 210 189 209
ERZU11JP511B 40 40 120 140
ERZU12JP511B 70 70 169 189
Delta 242 ― 760 1.45 (2) 20
ERZU13JP511B 95 95 219 239
ERZU14JP511B 125 125 260 280
ERZU11JP541 40 40 88 108
ERZU12JP541 70 70 105 125
ERZU13JP541 95 95 122 142
ERZU14JP541 Single 264 373 785 125 125 1.40 (1) 139 159 20
ERZU15JP541 150 150 156 176
ERZU16JP541 180 180 172 192
ERZU17JP541 210 210 189 209
ERZU11JP541B 40 40 121 141
ERZU12JP541B 70 70 171 191
Delta 264 ― 785 1.40 (2) 20
ERZU13JP541B 95 95 221 241
ERZU14JP541B 125 125 270 290

Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
113
For thyristor protection / E, J type
Ratings and characteristics (J type)
●Operating temperature range : ‒40 to 70 ℃ ●Storage temperature range : ‒40 to 110 ℃

Maximum allowable Maximum clamping Impulse life


Dimensions in mm
Part No. Connection voltage voltage 4
(2 ms, 10 times) Commutation
surge ratio
ACrms (V) DC (V) Vlp (V) lp (A) (A) Style A B C
ERZU21JP102 40 40 102 122
ERZU22JP102 70 70 135 155
ERZU23JP102 95 95 168 188
Single 484 684 1520 1.45 (1) 20
ERZU24JP102 125 125 199 219
ERZU25JP102 150 150 230 250
ERZU26JP102 180 180 261 281
ERZU21JP102B 40 40 166 186
Delta 484 ― 1520 1.45 (2) 20
ERZU22JP102B 70 70 261 281
ERZU21JP112 40 40 103 123
ERZU22JP112 70 70 136 156
ERZU23JP112 95 95 169 189
Single 528 746 1570 1.40 (1) 20
ERZU24JP112 125 125 200 220
ERZU25JP112 150 150 232 252
ERZU26JP112 180 180 264 284
ERZU21JP112B 40 40 168 188
Delta 528 ― 1570 1.40 (2) 20
ERZU22JP112B 70 70 264 284
ERZU21JP132F 40 40 149 169
ERZU22JP132F 70 70 182 202
ERZU23JP132F 95 95 214 234
Single 660 933 1900 1.35 (1) 40
ERZU24JP132F 125 125 246 266
ERZU25JP132F 150 150 278 298
ERZU26JP132F 180 180 310 330
ERZU21JP132H 40 40 213 233
Delta 660 ― 1900 1.35 (2) 40
ERZU22JP132H 70 70 309 329
ERZU21JP162F 40 40 150 170
ERZU22JP162F 70 70 184 204
ERZU23JP162F 95 95 218 238
Single 825 1167 2375 1.35 (1) 40
ERZU24JP162F 125 125 252 272
ERZU25JP162F 150 150 286 306
ERZU26JP162F 180 180 320 340
ERZU21JP162H 40 40 217 237
Delta 825 ― 2375 1.35 (2) 40
ERZU22JP162H 70 70 317 337
ERZU21JP192F 40 40 152 172
ERZU22JP192F 70 70 187 207
ERZU23JP192F 95 95 222 242
Single 990 1400 2850 1.35 (1) 40
ERZU24JP192F 125 125 257 277
ERZU25JP192F 150 150 292 312
ERZU26JP192F 180 180 327 347
ERZU21JP192H 40 40 222 242
Delta 990 ― 2850 1.35 (2) 40
ERZU22JP192H 70 70 327 347
ERZU21JP222F 40 40 154 174
ERZU22JP222F 70 70 190 210
Single 1100 1550 3325 1.35 (1) 40
ERZU23JP222F 95 95 227 247
ERZU24JP222F 125 125 264 284
ERZU21JP222H Delta 1100 ― 3325 40 40 1.35 (2) 227 247 40
ERZU31JP252F 40 40 167 187
ERZU32JP252F 70 70 218 238
Single 1320 1867 3800 1.35 (1) 40
ERZU33JP252F 95 95 269 289
ERZU34JP252F 125 125 320 340
ERZU31JP252H Delta 1320 ― 3800 40 40 1.35 (2) 266 288 40

Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
114
For thyristor protection / E, J type
Dimensions in mm (not to scale) (J type)

Style (1) Style (2)

104±1
104±1
M4 M4

141±1
60
122±1
60
N.P. N.P.

C
A A 6.5
6.5

3
B B
14 3

14

22
22

20 20
46 46

Unit : mm

Minimum quantity / Packing unit


Minimum quantity Packing quantity Carton (about)
Product Series / Type Part number / Packing unit in carton L×W×H (mm)
“ZNR” E type ERZC□□EK□□□P 5 100 300×355×65
For tyristor
Transient/surge
protection J type ERZU□□JP□□□ 1 ― 160×420×185
absorbers

Part No., quantity and country of origin are designated on outer packages in English.
※ Please contact local sales office about packing specifications.

Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
115
Safty Precautions
When using our products, no matter what sort of equipment they might be used for,
be sure to confirm the applications and environmental conditions with our specifications in advance.

Device Solutions Business Division


1006 Kadoma, Kadoma City, Osaka
571-8506 Japan

© Panasonic Industry 6OBVUIPSJ[FEEVQMJDBUJPOPGUIJTDBUBMPHJTTUSJDUMZGPSCJEEFO


5IFDPOUFOUTPGDBUBMPHBSFBTPG+VOF 2023.6