AWA0000COL22
AWA0000COL22
2023.6
Varistors (ZNR Surge Absorber) INDEX
Type Series Part number Page
Products system 3
Matters to Be Observed When Using This Product (D-type : V series / SMD-type : HF・VF series) 44
Performance characteristics /
HF series ERZHF□□□□□ 77
Recommendation land size
SMD type Performance characteristics /
VF series Recommendation land size / ERZVF□□□□□ 80
Minimum quantity
Matters to Be Observed When Using This Product (P, J, G-type / Arrestor box / E, J-type for thyristor) 101
Panasonic Industry will assume no liability whatsoever if the use of our company's
products deviates from the contents of this catalog or does not comply with the
precautions. Please be advised of these restrictions.
30-Jun-23
1
Varistors (ZNR Surge Absorber)
100
Voltage log
90
Maximum Clamping Voltage
Varistor voltage
Current (%)
Max. 50
Nom.
Min.
Fig.1. Example of V-I Characteristic of ZNR Fig.2.Standard Impulse Current Waveform (8/20 μs)
Note: *ZNR “Zinc Oxide Nonlinear Resistor” is a trade mark of voltage dependent resistor elements by
Panasonic. ZNR is in some cases named Metal Oxide Varistor “MOV”
3. Clamping voltage
Varistors have an abitity to limit a high voltage surge like lightning.
We call this limited voltage as “Clamping Voltage”. “Clamping Voltage” is measured by voltage between two
therminals using standard impulse current waveform (8/20 μs) shown in fig.2.
To avoid an exothermic influence.
Voltage
Time Time
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
2
Varistors (ZNR Surge Absorber)
Products system
●Varistor voltage:5 to 17 kV
For protection to switching
●Maximum peak current:5 to 10 kA
G type surge of high voltage (3.3, 6.6 kV)
(at 8/20 μs)
equipment
●Energy:1300 to 2600 J
Surge
Surge absorber with connected ●Varistor voltage:12 to 100 V
absorber
ZNRs and circuit breaker in box ●Maximum peak current:5000 A
units
Surge
●Varistor voltage:510 to 2500 V
absorbers Thristor protection against
●Impulse life:40 to 210 A
for switching surge of transformer
(2 ms, 104 times)
thyristor
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
3
Matters to Be Observed When Using This Product
Safety measures
An abnormal state of the D-type / E series varistor (ZNR surge absorber, hereinafter "the product" or "the surge absorber")
that results from a problem with service conditions (materials used, the surrounding environment, power conditions, circuit
conditions, etc.) may cause a fire accident, electric shock accident, burn accident, or product failure. Matters to note when
handling this product will hereinafter be described. What is described below should be checked sufficiently before the
product is used.
■ Take the following measures in order to avoid an accident caused by expected phenomenon.
(1) Destruction of the surge absorber may scatter its fractured pieces around. To protect other elements from these
pieces, set product in a case or shield it with a cover.
(2) Do not place the surge absorber near combustible materials (vinyl cable, resin mold, etc.). If avoiding the vicinity
of combustible materials is difficult, protect the combustible material with an incombustible cover.
(3) Surge absorber placed between lines
When the surge absorber is placed between lines, connect a normal type current fuse in series with the surge
absorber.
* See "Current fuse" in the "Circuit design and circuit board design" section.
(4) Surge absorber placed between a line and the ground
① When the surge absorber is placed between a line and the ground, even if the surge absorber short-circuits,
ground resistance will remain in the section between the line and the ground, leaving a possibility that the
current fuse won’t blow, in which case the outer sheath resin of the surge absorber may generate smoke or
ignite due to current flow. To prevent such a case, place an earth leakage breaker in a location closer to the
power supply than the surge absorber. When not using an earth leakage breaker, use a current fuse and
temperature fuse in series with each other.
* See Table 1 in the "Circuit design and circuit board design" section.
② When the surge absorber is placed between a live part and a metal case, it may cause electric shock if the
surge absorber short-circuits. To avoid this, ground the metal case or shield it to prevent direct contact with the
metal case.
■ In case the surge absorber should short-circuit and generate smoke or ignite, immediately cut off current flow
to the surge absorber.
■ An unexpected sharp rise in the working voltage, an incoming excessive surge, etc., may cause the surge absorber to
generate smoke or ignite.
In such a case, fire spreading through the device should be prevented to avoid expanded damage. To achieve this,
take a multi-protection measure, such as adopting fire-resistant materials that make up the outer shell components
and structural materials.
■ Do not use the surge absorber in which direct sunlight hits the surge absorber or near a heating element where the
temperature of the surge absorber would rise above its working temperature.
■ Do not use the surge absorber in a place where the surge absorber is exposed to wind or rain or a highly humid place
where steam is emitted or dew concentrates.
30-Jun-23
4
Matters to Be Observed When Using This Product
■ Do not use the surge absorber in a place filled with dust or salt, in an atmosphere contaminated with a corrosive gas,
etc., or in liquids such as water, oil, chemical, or organic solvents.
■ Do not wash the surge absorber with a solvent (thinner, acetone, etc.) that damages the outer sheath resin.
■ Choose a surge absorber whose maximum allowable circuit voltage has a margin relative to the maximum voltage range
including source voltage fluctuations.
* See Table 1 in the "Circuit design and circuit board design" section.
■ When surges are applied intermittently to the surge absorber at short intervals (when pulses of voltages are applied in a
noise simulator test, etc.), make sure that the surge power does not exceed the maximum average pulse power of the surge
absorber.
■ The product numbers of recommended surge absorbers to choose are shown in Table 1.
■ Current fuse
(1) Select a surge absorber and the rated current for a current fuse to be used in a manner shown in the following table.
Confirm that no secondary accident arises when the surge absorber in an actual circuit breaks. Selected rated currents of
current fuses shown in the following table are exemplary one and may vary depending on circuit conditions used. Confirm
the rated current by a test, etc., before using the current fuse.
<Rated currents of current fuses for the D-type / E/E-S1 series surge absorbers>
Standard
product number ERZE05A□□□ ERZE07A□□□ ERZE08A□□□ ERZE10A□□□ ERZE11A□□□ ERZE14A□□□
Rating
Current
5 A max. 7 A max. 7 A max. 10 A max. 10 A max. 10 A max.
* Use the rated voltage of the current fuse that corresponds to the circuit voltage of a circuit including the current fuse.
(2) Recommended parts where fuses are connected are shown in Table 1. When a load current to a protected device is so
large as to exceed the rated current of the fuse, however, connect the fuse in a location shown in the following diagram.
Current fuse
Power supply Protected
device
ZNR
■ Temperature fuse
When connecting the surge absorber to a temperature fuse, choose a connection method and a temperature fuse that allow
fine thermal coupling between the surge absorber and the temperature fuse.
30-Jun-23
5
Matters to Be Observed When Using This Product
Surge absorber placed between lines Surge absorber placed between a line and the ground
DC DC
Single-phase AC Single-phase AC
Current fuse ZNR1
Current fuse ZNR1 L
L
Protected
Protected device
device N
N ZNR2
Temperature
Thermal coupling fuse
Connection
Three-phase AC Three-phase AC
Current fuse
30-Jun-23
6
Matters to Be Observed When Using This Product
Processing conditions
■ Do not apply vibration, impact (drop impact, etc.), or pressure strong enough to crack the outer sheath resin or absorber
body of the surge absorber.
■ When coating the surge absorber with a resin or embedding it in a resin mold, avoid using a resin that degrades the
surge absorber.
■ Do not bend or apply a force to the lead of a D-type surge absorber close to the outer sheath resin.
■ When making holes for mounting the surge absorber on the board, check the dimensions of the holes on the board,
referencing the central point of the interval between the leads.
Because the overall dimensional tolerance is large, forming the holes with high precision requires careful processing.
Note 1: Soldering the surge absorber under soldering conditions different from the recommended soldering
conditions requires extra checking to ensure it won’t cause any problems.
Additional soldering is allowed only once. It must be done within 5 seconds, with the soldering iron
temperature kept at 400 ℃ or lower.
Note 2: A temperature profile may include a large error, depending on the measurement method used.
Be careful in such cases.
Note 3: Board temperatures vary depending on the sizes of boards and mounting densities. Confirm the
temperature for each type of board.
Time
■ Do not keep the product in a high-temperature or high-humidity condition. Keep the surge absorber in a room with
a temperature of 40 ℃ or lower and a relative humidity of 75% or lower and use the surge absorber within two years of
storage. Check the solderability of a surge absorber stored for a long period (two years or more) before using the surge
absorber.
■ Keep the surge absorber in a place where no corrosive gas atmosphere (hydrogen sulfide, sulfurous acid, chlorine,
ammonia, etc.) is present.
■ Keep the surge absorber in a place where the surge absorber is protected from direct sunlight, dew concentration, etc.
30-Jun-23
7
Varistors (ZNR Surge Absorber)
D type
E series
Features
●Large withstanding surge current capability in compact sizes
●Large “Energy Handling Capability” absorbing transient overvoltages in compact sizes
●Wide range of varistor voltages
●RoHS compliant
Recommended applications
●Transistor, diode, IC, thyristor or triac semiconductor protection
●Surge protection in consumer electronic equipment
●Surge protection in communication, measuring or controller electronics
●Surge protection in electronic home appliances, gas or petroleum appliances
Applicable standards
●UL1449 (VZCA2/UL, VZCA8/C-UL)
●VDE IEC61051-1,-2,-2-2,IEC60950-1 Annex.Q, IEC62368-1 G8.2
●CQC (GB/T10193, GB/T10194, GB4943.1, GB8898)
Refer to "Standard Products" , and "Application Note for Safety Standards" , for the details.
Refer to "Standard Products" , and "Application Note for Safety Standards" , for the details.
E R Z E
Product code Design No.
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
8
D type / E series
Reference guide to standard products
Varistor Clamping Maximum
Applicable Maximum
voltage voltage peak current
standards allowable voltage
Part No. at 1 mA at 8/20 μs at 8/20 μs (A)
Acrms DC
Type name Approvals (V) max.(V) lp (A) 1time 2times
(V) (V)
ERZE05A201 E201 ○☆◇ 340 10 1200 600
ERZE07A201 E7201 ○☆◇ 340 25 2500 1250
ERZE08A201 E8201 ○☆◇ 200 340 25 3500 2500
130 170
ERZE10A201 E10201 ○☆◇ (185 to 225) 340 50 4500 3000
ERZE11A201 E11201 ○☆★◇◆ 340 50 6000 5000
ERZE14A201 E14201 ○☆★◇◆ 340 100 10000 7000
ERZE05A221 E221 ○☆◇ 360 10 1200 600
ERZE07A221 E7221 ○☆◇ 360 25 2500 1250
ERZE08A221 E8221 ○☆◇ 220 360 25 3500 2500
140 180
ERZE10A221 E10221 ○☆◇ (198 to 242) 360 50 4500 3000
ERZE11A221 E11221 ○☆★◇◆ 360 50 6000 5000
ERZE14A221 E14221 ○☆★◇◆ 360 100 10000 7000
ERZE05A241 E241 ○☆◇ 395 10 1200 600
ERZE07A241 E7241 ○☆◇ 395 25 2500 1250
ERZE08A241 E8241 ○☆◇ 240 395 25 3500 2500
150 200
ERZE10A241 E10241 ○☆◇ (216 to 264) 395 50 4500 3000
ERZE11A241 E11241 ○☆★◇◆ 395 50 6000 5000
ERZE14A241 E14241 ○☆★◇◆ 395 100 10000 7000
ERZE05A271 E271 ○☆◇ 455 10 1200 600
ERZE07A271 E7271 ○☆◇ 455 25 2500 1250
ERZE08A271 E8271 ○☆◇ 270 455 25 3500 2500
175 225
ERZE10A271 E10271 ○☆◇ (247 to 303) 455 50 4500 3000
ERZE11A271 E11271 ○☆★◇◆ 455 50 6000 5000
ERZE14A271 E14271 ○☆★◇◆ 455 100 10000 7000
ERZE05A331 E331 ○☆◇ 545 10 1200 600
ERZE07A331 E7331 ○☆◇ 545 25 2500 1250
ERZE08A331 E8331 ○☆◇ 330 545 25 3500 2500
210 270
ERZE10A331 E10331 ○☆◇ (297 to 363) 545 50 4500 3000
ERZE11A331 E11331 ○☆★◇◆ 545 50 6000 4500
ERZE14A331 E14331 ○☆★◇◆ 545 100 10000 6500
ERZE05A361 E361 ○☆◇ 595 10 1200 600
ERZE07A361 E7361 ○☆◇ 595 25 2500 1250
ERZE08A361 E8361 ○☆◇ 360 595 25 3500 2500
230 300
ERZE10A361 E10361 ○☆◇ (324 to 396) 595 50 4500 3000
ERZE11A361 E11361 ○☆★◇◆ 595 50 6000 4500
ERZE14A361 E14361 ○☆★◇◆ 595 100 10000 6500
ERZE05A391 E391 ○☆◇ 650 10 1200 600
ERZE07A391 E7391 ○☆◇ 650 25 2500 1250
ERZE08A391 E8391 ○☆◇ 390 650 25 3500 2500
250 320
ERZE10A391 E10391 ○☆◇ (351 to 429) 650 50 4500 3000
ERZE11A391 E11391 ○☆★◇◆ 650 50 6000 4500
ERZE14A391 E14391 ○☆★◇◆ 650 100 10000 6500
ERZE05A431 E431 ○☆◇ 710 10 1200 600
ERZE07A431 E7431 ○☆◇ 710 25 2500 1250
ERZE08A431 E8431 ○☆◇ 430 710 25 3500 2500
275 350
ERZE10A431 E10431 ○☆◇ (387 to 473) 710 50 4500 3000
ERZE11A431 E11431 ○☆★◇◆ 710 50 6000 4500
ERZE14A431 E14431 ○☆★◇◆ 710 100 10000 6500
○: UL1449 (VZCA2/UL, VZCA8/C-UL), ☆ : VDE (IEC61051-1, -2, -2-2) ★ : VDE (IEC60950-1 Annex.Q, IEC62368-1 G8.2 ),
◇: CQC (GB/T10193, GB/T10194), ◆ : CQC (GB4943.1, GB8898)
※Approval number (File No.) of safety regulations are subject to revision without notice. Ask factory for a copy of the latest file No.
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
9
D type / E series
Reference guide to standard products
Varistor Clamping Maximum
Applicable Maximum
voltage voltage peak current
standards allowable voltage
Part No. at 1 mA at 8/20 μs at 8/20 μs (A)
Acrms DC
Type name Approvals (V) max.(V) lp (A) 1time 2times
(V) (V)
ERZE05A471 E471 ○☆◇ 775 10 1200 600
ERZE07A471 E7471 ○☆◇ 775 25 2500 1250
ERZE08A471 E8471 ○☆★◇◆ 470 775 25 3500 2500
300 385
ERZE10A471 E10471 ○☆★◇◆ (423 to 517) 775 50 4500 3000
ERZE11A471 E11471 ○☆★◇◆ 775 50 6000 4500
ERZE14A471 E14471 ○☆★◇◆ 775 100 10000 6500
ERZE07A511 E7511 ○☆◇ 845 25 2500 1250
ERZE08A511 E8511 ○☆★◇◆ 845 25 3500 2500
510
ERZE10A511 E10511 ○☆★◇◆ 320 410 845 50 4500 3000
(459 to 561)
ERZE11A511 E11511 ○☆★◇◆ 845 50 6000 4500
ERZE14A511 E14511 ○☆★◇◆ 845 100 10000 6500
ERZE07A561 E7561 ○☆◇ 930 25 2500 1250
ERZE08A561 E8561 ○☆★◇◆ 930 25 3500 2500
560
ERZE10A561 E10561 ○☆★◇◆ 350 450 930 50 4500 3000
(504 to 616)
ERZE11A561 E11561 ○☆★◇◆ 930 50 6000 4500
ERZE14A561 E14561 ○☆★◇◆ 930 100 10000 6500
ERZE07A621 E7621 ○☆◇ 1025 25 2500 1250
ERZE08A621 E8621 ○☆★◇◆ 1025 25 3500 2500
620
ERZE10A621 E10621 ○☆★◇◆ 385 505 1025 50 4500 3000
(558 to 682)
ERZE11A621 E11621 ○☆★◇◆ 1025 50 5000 4500
ERZE14A621 E14621 ○☆★◇◆ 1025 100 7500 6500
ERZE08A681 E8681 ○☆★◇◆ 1120 25 3500 2500
ERZE10A681 E10681 ○☆★◇◆ 680 1120 50 4500 3000
420 560
ERZE11A681 E11681 ○☆★◇◆ (612 to 748) 1120 50 5000 4500
ERZE14A681 E14681 ○☆★◇◆ 1120 100 7500 6500
ERZE08A751 E8751 ○☆★◇◆ 1240 25 3500 2500
ERZE10A751 E10751 ○☆★◇◆ 750 1240 50 4500 3000
460 615
ERZE11A751 E11751 ○☆★◇◆ (675 to 825) 1240 50 5000 4500
ERZE14A751 E14751 ○☆★◇◆ 1240 100 7500 6500
ERZE10A821 E10821 ○☆★◇◆ 1355 50 4500 3000
820
ERZE11A821 E11821 ○☆★◇◆ 510 670 1355 50 5000 4500
(738 to 902)
ERZE14A821 E14821 ○☆★◇◆ 1355 100 7500 6500
ERZE10A911 E10911 ○☆★◇◆ 1500 50 4500 3000
910
ERZE11A911 E11911 ○☆★◇◆ 550 745 1500 50 5000 4500
(819 to 1001)
ERZE14A911 E14911 ○☆★◇◆ 1500 100 7500 6500
ERZE10A102 E10102 ○☆★◇◆ 1650 50 4500 3000
1000
ERZE11A102 E11102 ○☆★◇◆ 625 825 1650 50 5000 4500
(900 to 1100)
ERZE14A102 E14102 ○☆★◇◆ 1650 100 7500 6500
ERZE10A112 E10112 ○☆★◇◆ 1815 50 4500 3000
1100
ERZE11A112 E11112 ○☆★◇◆ 680 895 1815 50 5000 4500
(990 to 1210)
ERZE14A112 E14112 ○☆★◇◆ 1815 100 7500 6500
○: UL1449 (VZCA2/UL, VZCA8/C-UL), ☆ : VDE (IEC61051-1, -2, -2-2) ★ : VDE (IEC60950-1 Annex.Q, IEC62368-1 G8.2 ),
◇: CQC (GB/T10193, GB/T10194), ◆ : CQC (GB4943.1, GB8898)
※Approval number (File No.) of safety regulations are subject to revision without notice. Ask factory for a copy of the latest file No.
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
10
D type / E5 series
Ratings and characteristics
●Operating temperature range : ‒40 to 85 ℃ ●Storage temperature range : ‒40 to 125 ℃
Maximum
Varistor Clamping Maximum energy peak current Capacitance
Maximum Rated
voltage voltage (8/20 μs) (max.)
allowable voltage power
Part No. at 1 mA (max.)**lp at 1 kHz
ERZE05A201 200(185 to 225) 130 170 340 0.25 13 9.5 1200 600 200
ERZE05A221 220(198 to 242) 140 180 360 0.25 14 10 1200 600 190
ERZE05A241 240(216 to 264) 150 200 395 0.25 15 11 1200 600 170
ERZE05A271 270(247 to 303) 175 225 455 0.25 18 13 1200 600 150
ERZE05A331 330(297 to 363) 210 270 545 0.25 21 15 1200 600 130
ERZE05A361 360(324 to 396) 230 300 595 0.25 23 17 1200 600 130
ERZE05A391 390(351 to 429) 250 320 650 0.25 26 19 1200 600 130
ERZE05A431 430(387 to 473) 275 350 710 0.25 29 21 1200 600 120
ERZE05A471 470(423 to 517) 300 385 775 0.25 32 23 1200 600 100
✽Ip Measuring current of clamping voltage : 10 A
L
ERZE05A391 7.0 5.9 5.0 10.0 3.2 F
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
11
D type / E5 series
Typical characteristics
Voltage vs. Current Impulse Derating (Relation between
impulse width and impulse current multiple)
Max.Leakage 10000
Current
Max.Clamping Voltage 2 times:5 min. interval
2000 up to 10 times:2 min. interval
up to 106 times : 10 sec. interval
471
431
471 391
431 361
331 1000
1000 391
271
900 361
241
800 221
700 201
600
Impulse Current(A)
500
100
400
300
Voltage(V)
200
10
331
100
221
90
80 1
70
60 Test current waveform
50 10–6 to 10–3 A: Direct current
10–1 to 104 A: 8/20 μs
40
30 0.1
10-6 10-5 10-4 10-3 10-2 10-1 100 101 102 103 104 105 20 100 1000 10000
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
12
D type / E7 series
Ratings and characteristics
●Operating temperature range : ‒40 to 85 ℃ ●Storage temperature range : ‒40 to 125 ℃
Maximum
Varistor Clamping Maximum energy peak current Capacitance
Maximum Rated
voltage voltage (8/20 μs) (max.)
allowable voltage power
Part No. at 1 mA (max.)**lp at 1 kHz
ERZE07A201 200(185 to 225) 130 170 340 0.3 26 19 2500 1250 360
ERZE07A221 220(198 to 242) 140 180 360 0.3 30 22 2500 1250 350
ERZE07A241 240(216 to 264) 150 200 395 0.3 33 24 2500 1250 340
ERZE07A271 270(247 to 303) 175 225 455 0.3 39 28 2500 1250 310
ERZE07A331 330(297 to 363) 210 270 545 0.3 44 32 2500 1250 280
ERZE07A361 360(324 to 396) 230 300 595 0.3 50 36 2500 1250 260
ERZE07A391 390(351 to 429) 250 320 650 0.3 53 38 2500 1250 240
ERZE07A431 430(387 to 473) 275 350 710 0.3 60 43 2500 1250 210
ERZE07A471 470(423 to 517) 300 385 775 0.3 65 47 2500 1250 170
ERZE07A511 510(459 to 561) 320 410 845 0.3 70 50 2500 1250 140
ERZE07A561 560(504 to 616) 350 450 930 0.3 75 55 2500 1250 140
ERZE07A621 620(558 to 682) 385 505 1025 0.3 80 60 2500 1250 135
✽Ip Measuring current of clamping voltage : 25 A
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
13
D type / E7 series
Typical characteristics
Voltage vs. Current Impulse Derating (Relation between
impulse width and impulse current multiple)
10000
Max.Leakage
Current Max.Clamping Voltage 2 times:5 min. interval
2000 621 up to 10 times:2 min. interval
561 up to 106 times : 10 sec. interval
511
471
431
561 391
511 361
331
1000 471
431
900 391
271 1000
361 241
800 221
700 201
600
500
Impulse Current(A)
400
Voltage(V)
300 100
200
100
10
90 331
80 221
70
60
50 Test current waveform
10–6 to 10–3 A: Direct current
40 10–1 to 104 A: 8/20 μs
30 1
10-6 10-5 10-4 10-3 10-2 10-1 100 101 102 103 104 105
20 100 1000 10000
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
14
D type / E8 series
Ratings and characteristics
●Operating temperature range : ‒40 to 85 ℃ ●Storage temperature range : ‒40 to 125 ℃
Maximum
Varistor Clamping Maximum energy peak current Capacitance
Maximum Rated
voltage voltage (8/20 μs) (max.)
allowable voltage power
Part No. at 1 mA (max.)**lp at 1 kHz
(10/1000 μs) (2 ms) 1 time 2 times
ACrms DC
(V) (V) (W) (J) (J) (A) (A) (pF)
(V) (V)
ERZE08A201 200(185 to 225) 130 170 340 0.4 35 25 3500 2500 390
ERZE08A221 220(198 to 242) 140 180 360 0.4 39 27.5 3500 2500 380
ERZE08A241 240(216 to 264) 150 200 395 0.4 42 30 3500 2500 360
ERZE08A271 270(247 to 303) 175 225 455 0.4 49 35 3500 2500 330
ERZE08A331 330(297 to 363) 210 270 545 0.4 58 42 3500 2500 300
ERZE08A361 360(324 to 396) 230 300 595 0.4 65 45 3500 2500 280
ERZE08A391 390(351 to 429) 250 320 650 0.4 70 50 3500 2500 260
ERZE08A431 430(387 to 473) 275 350 710 0.4 80 55 3500 2500 230
ERZE08A471 470(423 to 517) 300 385 775 0.4 85 60 3500 2500 180
ERZE08A511 510(459 to 561) 320 410 845 0.4 92 67 3500 2500 150
ERZE08A561 560(504 to 616) 350 450 930 0.4 92 67 3500 2500 150
ERZE08A621 620(558 to 682) 385 505 1025 0.4 92 67 3500 2500 140
ERZE08A681 680(612 to 748) 420 560 1120 0.4 92 67 3500 2500 130
ERZE08A751 750(675 to 825) 460 615 1240 0.4 100 70 3500 2500 130
✽Ip Measuring current of clamping voltage : 25 A
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
15
D type / E8 series
Typical characteristics
Voltage vs. Current Impulse Derating (Relation between
impulse width and impulse current multiple)
511
471
431
391
1000 471 361
431 331
900 271 1000
800 391
241
361
700 221
201
600
500
Impulse Current(A)
Voltage(V)
400
300 100
200
100
10
90 331
80
221
70
60
50 Test current waveform
10–6 to 10–3 A: Direct current
10–1 to 104 A: 8/20 μs
40
30 1
10-6 10-5 10-4 10-3 10-2 10-1 100 101 102 103 104 105 20 100 1000 10000
1000
2000
751
681
621
Impulse Current(A)
561
Voltage(V)
1000
100
900
800
700
600
500
10
400
300 751
681 Test current waveform
10–6 to 10–3 A: Direct current
621 10–1 to 104 A: 8/20 μs
200 1
10-6 10-5 10-4 10-3 10-2 10-1 100 101 102 103 104 105 20 100 1000 10000
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
16
D type / E10 series
Ratings and characteristics
●Operating temperature range : ‒40 to 85 ℃ ●Storage temperature range : ‒40 to 125 ℃
Maximum
Varistor Clamping Maximum energy peak current Capacitance
Maximum Rated
voltage voltage (8/20 μs) (max.)
allowable voltage power
Part No. at 1 mA (max.)**lp at 1 kHz
(10/1000 μs) (2 ms) 1 time 2 times
ACrms DC
(V) (V) (W) (J) (J) (A) (A) (pF)
(V) (V)
ERZE10A201 200(185 to 225) 130 170 340 0.5 47 34 4500 3000 630
ERZE10A221 220(198 to 242) 140 180 360 0.5 50 36 4500 3000 600
ERZE10A241 240(216 to 264) 150 200 395 0.5 56 40 4500 3000 570
ERZE10A271 270(247 to 303) 175 225 455 0.5 64 46 4500 3000 530
ERZE10A331 330(297 to 363) 210 270 545 0.5 72 52 4500 3000 470
ERZE10A361 360(324 to 396) 230 300 595 0.5 84 60 4500 3000 430
ERZE10A391 390(351 to 429) 250 320 650 0.5 91 65 4500 3000 400
ERZE10A431 430(387 to 473) 275 350 710 0.5 99 71 4500 3000 350
ERZE10A471 470(423 to 517) 300 385 775 0.5 106 76 4500 3000 320
ERZE10A511 510(459 to 561) 320 410 845 0.5 117 84 4500 3000 300
ERZE10A561 560(504 to 616) 350 450 930 0.5 120 86 4500 3000 290
ERZE10A621 620(558 to 682) 385 505 1025 0.5 126 88 4500 3000 280
ERZE10A681 680(612 to 748) 420 560 1120 0.5 133 95 4500 3000 260
ERZE10A751 750(675 to 825) 460 615 1240 0.5 140 100 4500 3000 250
ERZE10A821 820(738 to 902) 510 670 1355 0.5 154 110 4500 3000 230
ERZE10A911 910(819 to 1001) 550 745 1500 0.5 168 112 4500 3000 220
ERZE10A102 1000(900 to 1100) 625 825 1650 0.5 182 130 4500 3000 200
ERZE10A112 1100(990 to 1210) 680 895 1815 0.5 196 140 4500 3000 180
✽Ip Measuring current of clamping voltage : 50 A
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
17
D type / E10 series
Typical characteristics
Voltage vs. Current Impulse Derating (Relation between
impulse width and impulse current multiple)
500
Impulse Current(A)
400
Voltage (V)
300 100
200
100
331 10
90
221
80
70
60 Test current waveform
50 10–6 to 10–3 A: Direct current
10–1 to 104 A: 8/20 μs
40
30 1
10-6 10-5 10-4 10-3 10-2 10-1 100 101 102 103 104 105 20 100 1000 10000
102
911
Voltage(V)
821
1000 100
900
800
700
600
500
10
400
200 1
10-6 10-5 10-4 10-3 10-2 10-1 100 101 102 103 104 105 20 100 1000 10000
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
18
D type / E11 series
Ratings and characteristics
●Operating temperature range : ‒40 to 85 ℃ ●Storage temperature range : ‒40 to 125 ℃
Maximum
Varistor Clamping Maximum energy peak current Capacitance
Maximum Rated
voltage voltage (8/20 μs) (max.)
allowable voltage power
Part No. at 1 mA (max.)**lp at 1 kHz
(10/1000 μs) (2 ms) 1 time 2 times
ACrms DC
(V) (V) (W) (J) (J) (A) (A) (pF)
(V) (V)
ERZE11A201 200(185 to 225) 130 170 340 0.6 70 50 6000 5000 690
ERZE11A221 220(198 to 242) 140 180 360 0.6 78 55 6000 5000 660
ERZE11A241 240(216 to 264) 150 200 395 0.6 84 60 6000 5000 620
ERZE11A271 270(247 to 303) 175 225 455 0.6 99 70 6000 5000 580
ERZE11A331 330(297 to 363) 210 270 545 0.6 115 80 6000 4500 520
ERZE11A361 360(324 to 396) 230 300 595 0.6 130 90 6000 4500 480
ERZE11A391 390(351 to 429) 250 320 650 0.6 140 100 6000 4500 450
ERZE11A431 430(387 to 473) 275 350 710 0.6 155 110 6000 4500 400
ERZE11A471 470(423 to 517) 300 385 775 0.6 175 125 6000 4500 360
ERZE11A511 510(459 to 561) 320 410 845 0.6 190 136 6000 4500 310
ERZE11A561 560(504 to 616) 350 450 930 0.6 190 136 6000 4500 310
ERZE11A621 620(558 to 682) 385 505 1025 0.6 190 136 5000 4500 300
ERZE11A681 680(612 to 748) 420 560 1120 0.6 190 136 5000 4500 290
ERZE11A751 750(675 to 825) 460 615 1240 0.6 210 150 5000 4500 280
ERZE11A821 820(738 to 902) 510 670 1355 0.6 235 165 5000 4500 260
ERZE11A911 910(819 to 1001) 550 745 1500 0.6 255 180 5000 4500 240
ERZE11A102 1000(900 to 1100) 625 825 1650 0.6 280 200 5000 4500 220
ERZE11A112 1100(990 to 1210) 680 895 1815 0.6 310 220 5000 4500 200
✽Ip Measuring current of clamping voltage : 50 A
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
19
D type / E11 series
Typical characteristics
Voltage vs. Current Impulse Derating (Relation between
impulse width and impulse current multiple)
Impulse Current(A)
500
400
Voltage(V)
300 100
200
100
90 331 10
80 221
70
60
Test current waveform
50 10–6 to 10–3 A: Direct current
10–1 to 104 A: 8/20 μs
40
30
10-6 10-5 10-4 10-3 10-2 10-1 100 101 102 103 104 105 120 100 1000 10000
Current(A) Impulse Width(μs)
3000 112
102
911
821 1000
2000 751
681
102 621
561
Impulse Current(A)
911
821
Voltage(V)
1000 100
900
800
700
600
500
10
400
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
20
D type / E14 series
Ratings and characteristics
●Operating temperature range : ‒40 to 85 ℃ ●Storage temperature range : ‒40 to 125 ℃
Maximum
Varistor Clamping Maximum energy peak current Capacitance
Maximum Rated
voltage voltage (8/20 μs) (max.)
allowable voltage power
Part No. at 1 mA (max.)**lp at 1 kHz
(10/1000 μs) (2 ms) 1 time 2 times
ACrms DC
(V) (V) (W) (J) (J) (A) (A) (pF)
(V) (V)
ERZE14A201 200(185 to 225) 130 170 340 1.0 140 100 10000 7000 1300
ERZE14A221 220(198 to 242) 140 180 360 1.0 155 110 10000 7000 1200
ERZE14A241 240(216 to 264) 150 200 395 1.0 168 120 10000 7000 1100
ERZE14A271 270(247 to 303) 175 225 455 1.0 190 135 10000 7000 1000
ERZE14A331 330(297 to 363) 210 270 545 1.0 228 160 10000 6500 900
ERZE14A361 360(324 to 396) 230 300 595 1.0 255 180 10000 6500 900
ERZE14A391 390(351 to 429) 250 320 650 1.0 275 195 10000 6500 800
ERZE14A431 430(387 to 473) 275 350 710 1.0 303 215 10000 6500 800
ERZE14A471 470(423 to 517) 300 385 775 1.0 350 250 10000 6500 750
ERZE14A511 510(459 to 561) 320 410 845 1.0 382 273 10000 6500 700
ERZE14A561 560(504 to 616) 350 450 930 1.0 382 273 10000 6500 700
ERZE14A621 620(558 to 682) 385 505 1025 1.0 382 273 7500 6500 650
ERZE14A681 680(612 to 748) 420 560 1120 1.0 382 273 7500 6500 600
ERZE14A751 750(675 to 825) 460 615 1240 1.0 420 300 7500 6500 530
ERZE14A821 820(738 to 902) 510 670 1355 1.0 460 325 7500 6500 500
ERZE14A911 910(819 to 1001) 550 745 1500 1.0 510 360 7500 6500 400
ERZE14A102 1000(900 to 1100) 625 825 1650 1.0 565 400 7500 6500 400
ERZE14A112 1100(990 to 1210) 680 895 1815 1.0 620 440 7500 6500 350
✽Ip Measuring current of clamping voltage : 100 A
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
21
D type / E14 series
Typical characteristics
Voltage vs. Current Impulse Derating (Relation between
impulse width and impulse current multiple)
400
300 100
200
100 10
90
80 241
70 331
60 221
30 1
10-6 10-5 10-4 10-3 10-2 10-1 100 101 102 103 104 105 20 100 1000 10000
3000 112
102
911
821 1000
2000 751
681
621
561
Impulse Current(A)
102
Voltage(V)
911
821
1000 100
900
800
700
600
500
10
400
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
22
D type / E series (Leads cut type)
Straight leads cut type (Bulk type)
※ Ratings and characteristics is refer to bulk standard type.
ød
B
W L*
D 7.0 max. 9.0 max. 9.0 max. 10.0 max. 10.5 max. 11.5 max. 11.5 max. 12.5 max. 13.0 max. 14.0 max.
H 10.0 max. 12.5 max. 13.5 max. 13.5 max. 13.5 max. 14.5 max. 15.0 max. 16.0 max. 17.0 max. 18.0 max.
W 5.0±1.0 7.5±1.0 7.5±1.0 7.5±1.0 7.5±1.0 7.5±1.0 7.5±1.0 7.5±1.0 7.5±1.0 7.5±1.0
+0.06 +0.08 +0.08 +0.08 +0.08 +0.08 +0.08 +0.08 +0.08 +0.08
ød 0.60
-0.05
0.80
-0.05
0.80
-0.05
0.80
-0.05
0.80
-0.05
0.80
-0.05
0.80
-0.05
0.80
-0.05
0.80
-0.05
0.80
-0.05
B 4.0±1.0 4.0±1.0 4.0±1.0 4.0±1.0 4.0±1.0 4.0±1.0 4.0±1.0 4.0±1.0 4.0±1.0 4.0±1.0
Standard
products part No.
ERZE05A□□□CS ERZE07A□□□CS ERZE08A□□□CS ERZE10A□□□CS ERZE11A□□□CS
***
C
C
ød
B
W L*
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
23
D type / E series (Taping specifications)
Taping specifications for automated assembly (Straight leads and taping)
※ Ratings and characteristics is refer to bulk standard type.
Dimensions in mm (not to scale)
P2 P øD △h
T*
A
P1
W2
H0
F1
H
W0
W1
L
Position of
W
F
H0 dimension
P0 ød øD0 Position of
F1 dimension
t
✽ Dimension “T”: Conforms to each individual specification.
Unit : mm
P 12.7±1.0 15.0±1.0 15.0±1.0 15.0±1.0 15.0±1.0 15.0±1.0 15.0±1.0 15.0±1.0 15.0±1.0 15.0±1.0 15.0±1.0 15.0±1.0 15.0±1.0 15.0±1.0
P0 12.7±0.3 15.0±0.3 15.0±0.3 15.0±0.3 15.0±0.3 15.0±0.3 15.0±0.3 15.0±0.3 15.0±0.3 15.0±0.3 15.0±0.3 15.0±0.3 15.0±0.3 15.0±0.3
P1 3.85±0.70 3.75±0.70 3.75±0.70 3.75±0.70 3.75±0.70 3.75±0.70 3.75±0.70 3.75±0.70 3.75±0.70 3.75±0.70 3.75±0.70 3.75±0.70 3.75±0.70 3.75±0.70
P2 6.36±1.30 7.5±1.3 7.5±1.3 7.5±1.3 7.5±1.3 7.5±1.3 7.5±1.3 7.5±1.3 7.5±1.3 7.5±1.3 7.5±1.3 7.5±1.3 7.5±1.3 7.5±1.3
+0.06 +0.08 +0.08 +0.08 +0.08 +0.08 +0.08 +0.08 +0.08 +0.08 +0.08 +0.08 +0.08 +0.08
ød 0.60
-0.05
0.80
-0.05
0.80
-0.05
0.80
-0.05
0.80
-0.05
0.80
-0.05
0.80
-0.05
0.80
-0.05
0.80
-0.05
0.80
-0.05
0.80
-0.05
0.80
-0.05
0.80
-0.05
0.80
-0.05
F 5.0±0.5 7.5±0.5 7.5±0.5 7.5±0.5 7.5±0.5 7.5±0.5 7.5±0.5 7.5±0.5 7.5±0.5 7.5±0.5 7.5±0.5 7.5±0.5 7.5±0.5 7.5±0.5
△h 0±2 0±2 0±2 0±2 0±2 0±2 0±2 0±2 0±2 0±2 0±2 0±2 0±2 0±2
+1.0 +1.0 +1.0 +1.0 +1.0 +1.0 +1.0 +1.0 +1.0 +1.0 +1.0 +1.0 +1.0 +1.0
W 18.0
-0.5
18.0
-0.5
18.0
-0.5
18.0
-0.5
18.0
-0.5
18.0
-0.5
18.0
-0.5
18.0
-0.5
18.0
-0.5
18.0
-0.5
18.0
-0.5
18.0
-0.5
18.0
-0.5
18.0
-0.5
W0 5.0 min. 5.0 min. 5.0 min. 5.0 min. 5.0 min. 5.0 min. 5.0 min. 5.0 min. 5.0 min. 5.0 min. 5.0 min. 5.0 min. 5.0 min. 5.0 min.
W1 9.0±0.5 9.0±0.5 9.0±0.5 9.0±0.5 9.0±0.5 9.0±0.5 9.0±0.5 9.0±0.5 9.0±0.5 9.0±0.5 9.0±0.5 9.0±0.5 9.0±0.5 9.0±0.5
W2 3.0 max. 3.0 max. 3.0 max. 3.0 max. 3.0 max. 3.0 max. 3.0 max. 3.0 max. 3.0 max. 3.0 max. 3.0 max. 3.0 max. 3.0 max. 3.0 max.
H Approx. 22 Approx. 22 Approx. 22 Approx. 22 Approx. 22 Approx. 22 Approx. 22 Approx. 22 Approx. 22 Approx. 22 Approx. 22 Approx. 22 Approx. 22 Approx. 22
+2.0 +2.0 +2.0 +2.0
H0 17.0±0.5 18.0
0
―― ―― ―― 18.0
0
―― ―― 18.0
0
―― ―― 18.0
0
―― ――
ø D0 ø4.0±0.2 ø4.0±0.2 ø4.0±0.2 ø4.0±0.2 ø4.0±0.2 ø4.0±0.2 ø4.0±0.2 ø4.0±0.2 ø4.0±0.2 ø4.0±0.2 ø4.0±0.2 ø4.0±0.2 ø4.0±0.2 ø4.0±0.2
t 0.6±0.3 0.6±0.3 0.6±0.3 0.6±0.3 0.6±0.3 0.6±0.3 0.6±0.3 0.6±0.3 0.6±0.3 0.6±0.3 0.6±0.3 0.6±0.3 0.6±0.3 0.6±0.3
L 11.0 max. 11.0 max. 11.0 max. 11.0 max. 11.0 max. 11.0 max. 11.0 max. 11.0 max. 11.0 max. 11.0 max. 11.0 max. 11.0 max. 11.0 max. 11.0 max.
øD 7.0 max. 9.0 max. 9.0 max. 9.0 max. 10.0 max. 10.5 max. 10.5 max. 11.5 max. 11.5 max. 11.5 max. 12.5 max. 13.0 max. 13.0 max. 14.0 max.
A 10.0 max. 12.5 max. 12.5 max. 13.5 max. 13.5 max. 13.5 max. 13.5 max. 14.5 max. 15.0 max. 15.0 max. 16.0 max. 17.0 max. 17.0 max. 18.0 max.
Standard
products part
ERZE05E □□ ERZE07E□□□ ERZE08E□□□ ERZE10E□□□ ERZE11E□□□
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
24
D type / E series (Taping specifications)
Taping specifications for automated assembly (Crimped leads and taping)
※ Ratings and characteristics is refer to bulk standard type.
Dimensions in mm (not to scale)
P2 P øD △h
T*
A
P1
W2
H0
H
W0
W1
L
W
F
P0 ød øD0
t
✽ Dimension “T”: Conforms to each individual specification.
Unit : mm
P0 12.7±0.3 15.0±0.3 15.0±0.3 15.0±0.3 15.0±0.3 15.0±0.3 15.0±0.3 15.0±0.3 15.0±0.3 15.0±0.3 15.0±0.3 15.0±0.3 15.0±0.3
P1 3.85±0.70 3.75±0.70 3.75±0.70 3.75±0.70 3.75±0.70 3.75±0.70 3.75±0.70 3.75±0.70 3.75±0.70 3.75±0.70 3.75±0.70 3.75±0.70 3.75±0.70
P2 6.36±1.30 7.5±1.3 7.5±1.3 7.5±1.3 7.5±1.3 7.5±1.3 7.5±1.3 7.5±1.3 7.5±1.3 7.5±1.3 7.5±1.3 7.5±1.3 7.5±1.3
+0.06 +0.08 +0.08 +0.08 +0.08 +0.08 +0.08 +0.08 +0.08 +0.08 +0.08 +0.08 +0.08
ød 0.60
-0.05
0.80
-0.05
0.80
-0.05
0.80
-0.05
0.80
-0.05
0.80
-0.05
0.80
-0.05
0.80
-0.05
0.80
-0.05
0.80
-0.05
0.80
-0.05
0.80
-0.05
0.80
-0.05
F 5.0±0.5 7.5±0.5 7.5±0.5 7.5±0.5 7.5±0.5 7.5±0.5 7.5±0.5 7.5±0.5 7.5±0.5 7.5±0.5 7.5±0.5 7.5±0.5 7.5±0.5
△h 0±2 0±2 0±2 0±2 0±2 0±2 0±2 0±2 0±2 0±2 0±2 0±2 0±2
+1.0 +1.0 +1.0 +1.0 +1.0 +1.0 +1.0 +1.0 +1.0 +1.0 +1.0 +1.0 +1.0
W 18.0
-0.5
18.0
-0.5
18.0
-0.5
18.0
-0.5
18.0
-0.5
18.0
-0.5
18.0
-0.5
18.0
-0.5
18.0
-0.5
18.0
-0.5
18.0
-0.5
18.0
-0.5
18.0
-0.5
W0 5.0 min. 5.0 min. 5.0 min. 5.0 min. 5.0 min. 5.0 min. 5.0 min. 5.0 min. 5.0 min. 5.0 min. 5.0 min. 5.0 min. 5.0 min.
W1 9.0±0.5 9.0±0.5 9.0±0.5 9.0±0.5 9.0±0.5 9.0±0.5 9.0±0.5 9.0±0.5 9.0±0.5 9.0±0.5 9.0±0.5 9.0±0.5 9.0±0.5
W2 3.0 max. 3.0 max. 3.0 max. 3.0 max. 3.0 max. 3.0 max. 3.0 max. 3.0 max. 3.0 max. 3.0 max. 3.0 max. 3.0 max. 3.0 max.
H Approx. 22 Approx. 22 Approx. 22 Approx. 22 Approx. 22 Approx. 22 Approx. 22 Approx. 22 Approx. 22 Approx. 22 Approx. 22 Approx. 22 Approx. 22
H0 17.0±0.5 16.0±0.5 16.0±0.5 16.0±0.5 16.0±0.5 16.0±0.5 16.0±0.5 16.0±0.5 16.0±0.5 16.0±0.5 16.0±0.5 16.0±0.5 16.0±0.5
ø D0 ø4.0±0.2 ø4.0±0.2 ø4.0±0.2 ø4.0±0.2 ø4.0±0.2 ø4.0±0.2 ø4.0±0.2 ø4.0±0.2 ø4.0±0.2 ø4.0±0.2 ø4.0±0.2 ø4.0±0.2 ø4.0±0.2
t 0.6±0.3 0.6±0.3 0.6±0.3 0.6±0.3 0.6±0.3 0.6±0.3 0.6±0.3 0.6±0.3 0.6±0.3 0.6±0.3 0.6±0.3 0.6±0.3 0.6±0.3
L 11.0 max. 11.0 max. 11.0 max. 11.0 max. 11.0 max. 11.0 max. 11.0 max. 11.0 max. 11.0 max. 11.0 max. 11.0 max. 11.0 max. 11.0 max.
øD 7.0 max. 9.0 max. 9.0 max. 10.0 max. 10.5 max. 10.5 max. 11.5 max. 11.5 max. 12.5 max. 12.5 max. 13.0 max. 13.0 max. 14.0 max.
A 13.0 max. 15.5 max. 16.5 max. 16.5 max. 17.0 max. 17.0 max. 18.0 max. 18.0 max. 19.5 max. 20.5 max. 20.5 max. 20.5 max. 21.5 max.
Standard
products part
ERZE05F□□□ ERZE07F□□□ ERZE08F□□□ ERZE10F□□□ ERZE11F□□□
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
25
D type / E series
Application note for safety standards
● Approvals products lists in "Reference Guide to Standard Products."
● UL and VDE : Registered in "Type name", it isn’t registered in "Panasonic Part No."
● CQC : Registered in "Panasonic Part No."
● "Rated Voltages" are specified for UL recognized components in list shown below.
✽:5 Series is blank, 7 series is 7, 8 series is 8, 10 series is 10, 11 series is 11, 14 series is 14
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
26
D type / E series
Explanation of the contents
Mark Explanation of the content
Abbreviation of
□□□
E✽□□□ part No.
(Type Name) Nominal varistor volage
Jan : 1 to Sep : 9,
◇ Monthly code
Oct. : 0, Nov. : N,Dec. : D
Marking contents
Series
(Example)
5 7 8 10 11 14
Varister voltage (ERZE05A□□□) (ERZE07A□□□) (ERZE08A□□□) (ERZE10A□□□) (ERZE11A□□□) (ERZE14A□□□)
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
27
D type / E series
Performance characteristics
Characteristics Test methods / description Specifications
Maximum The maximum sinusoidal RMS voltage or maximum DC voltage that can be applied
allowable voltage continuously.
The maximum voltage between two terminals with the specified
standard impulse current (8/20 μs) illustrated below applied.
100
90
Current (%)
Clamping voltage
50
To meet the
10
0 specified value.
8 μs Time
20 μs
Rated power The power that can be applied in the specified ambient temperature.
The maximum energy within the varistor voltage change of ±10 % when a single
Maximum energy
impulse current of 2 ms or 10/1000 μs is applied.
The maximum current within the varistor voltage change of ±10 % when a standard
Maximum 2times
peak current
impulse current of 8/20 μs is applied two times with an interval of 5 minutes.
(Withstanding
Electrical
surge
The maximum current within the varistor voltage change of ±10 % with a single
current) 1time
standard impulse current of 8/20 μs is applied.
Withstanding voltage AC 1500 Vrms shall be applied between both terminals of the specimen connected
No breakdown
(Body insulation) together and metal foil closely wrapped round its body for 1 minute.
The change of VC shall be measured after the impulse current listed below is applied
10000 or 100000 times continuously with the interval of 10 seconds at room
temperature.
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
28
D type / E series
Performance characteristics
Characteristics Test methods / description Specifications
After gradually applying the force specified below and keeping the unit fixed for 10
seconds, the terminal shall be visually examined for any damage.
Robustness of
terminations
Terminal diameter Force
(Tensile)
ø0.6 mm, ø0.8 mm 9.8 N
ø1.0 mm 19.6 N
The unit shall be secured with its terminal kept vertical and the force specified below
shall be applied in the axial direction. The terminal shall gradually be bent by 90 ° in
one direction, then 90 ° in the opposite direction, and again back to the original No remarkable mechanical
Robustness of position. The damage of the terminal shall be visually examined. damage
terminations
(Bending)
Terminal diameter Force
Mechanical
After repeadly applying a single harmonic vibration (amplitude: 0.75 mm, double
amplitude: 1.5 mm) with 1 minute vibration frequency cycles (10 Hz to 55 Hz to 10 Hz)
Vibration
to each of three perpendicular directions for 2 hours. Thereafter, the unit shall be
visually examined.
Approximately 95 %
After dipping the terminals to a depth of approximately 3 mm from the body in a of the termainals shall
Solderability
soldering bath of 235±5℃ for 2±0.5 seconds, the terminal shall be visually examined. be covered with new
solder uniformly.
After each lead shall be dipped into a solder bath having a temperature
of 260±5℃ to a point 2.0 to 2.5 mm from the body of the unit, using
Resistance to
soldering heat
shielding board (t=1.5 mm), be held there for 10±1 s and then be stored ΔV1mA/V1mA ≦ ±5 %
at room temperature and normal humidity for 1 to 2 hours. The change of
VCmA and mechanical damages shall be examined.
The specimen shall be subjected to 125±2℃ for 1000 hours in a thermostatic bath
High temperature
storage/Dry heat
without load and then stored at room temperature and normal humidity for 1 to 2 hours. ΔV1mA/V1mA ≦ ±5 %
Thereafter, the change of VCmA shall be measured.
mechanical damage
2 Room temperature 15±3
3 125±2 30±3
4 Room temperature 15±3
After being continuously applied the Maximum Allowable Voltage at 85±2℃ for 1000
High temperature
hours, the specimen shall be stored at room temperature and normal humidity for 1 to
load/Dry heat load
2 hours. Thereafter, the change of VCmA shall be measured.
ΔV1mA/V1mA ≦ ±10 %
The specimen shall be subjected to 40±2℃, 90 to 95 % RH and the
Damp heat load/ Maximum Allowable Voltage for 1000 hours and then stored at room
Humidity load temperature and normal humidity for 1 to 2 hours. Thereafter, the change of VCmA
shall be measured.
The specimen shall be subjected to –40±2℃ without load for 1000 hours and then
Low temperature
storage/Cold
stored at room temperature and normal humidity for 1 to 2 hours. Thereafter, the ΔV1mA/V1mA ≦ ±5 %
change of VCmA shall be measured.
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
29
D type / E series
Minimum quantity / Packing unit
Minimum
Packing quantity Carton (about)
Product Series / Type Part number quantity
/ Packing unit
in carton L×W×H (mm)
ERZE05A201 to 471 100 10000 210×340×180
ERZE07A201 to 391 50 3000 210×340×110
ERZE07A431 to 621 50 3000 210×340×110
ERZE08A201 to 331 50 3000 210×340×110
ERZE08A361 to 511 50 3000 210×340×110
ERZE08A561 to 751 50 2000 210×340×110
ERZE10A201 to 241 50 3000 210×340×110
Straight leads
ERZE10A271 to 431 50 3000 210×340×110
<Bulk>
ERZE10A471 to 112 50 2000 210×340×110
ERZE11A201 to 361 50 3000 210×340×110
ERZE11A391 to 561 50 2000 210×340×110
ERZE11A621 to 112 50 1000 210×340×110
ERZE14A201 to 221 50 2000 210×340×110
ERZE14A241 to 431 50 2000 210×340×110
ERZE14A471 to 112 50 1000 210×340×110
ERZE05A(B)201CS to 471CS 100 10000 210×340×180
ERZE07A(B)201CS to 391CS 100 4000 210×340×110
ERZE07A(B)431CS to 621CS 50 4000 210×340×110
ERZE08A(B)201CS to 331CS 100 4000 210×340×110
ERZE08A(B)361CS to 511CS 50 4000 210×340×110
Leads cut type ERZE08A(B)561CS to 751CS 50 3000 210×340×110
<Bulk> ERZE10A(B)201CS to 241CS 100 4000 210×340×110
ERZE10A(B)271CS to 431CS 50 4000 210×340×110
ERZE10A(B)471CS to 112CS 50 3000 210×340×110
ERZE11A(B)201CS to 361CS 50 3000 210×340×110
ERZE11A(B)391CS to 561CS 50 2000 210×340×110
ERZE11A(B)621CS to 112CS 50 2000 210×340×110
Varistors ERZE05E201 to 471 1000 10000 400×360×260
D type
(ZNR Surge ERZE07E201 to 271 1000 10000 400×360×260
E series
Absorber) ERZE07E331 to 471 1000 10000 470×360×260
ERZE07E511 to 621 500 5000 400×360×260
ERZE08E201 to 271 1000 5000 360×310×320
ERZE08E331 to 431 1000 5000 360×310×320
ERZE08E471 to 511 1000 5000 360×310×320
Straight leads
ERZE08E561 to 751 500 2500 360×270×320
and taped
ERZE10E201 to 241 1000 5000 360×310×320
ERZE10E271 to 471 1000 5000 360×310×320
ERZE10E511 to 561 1000 5000 360×310×320
ERZE10E621 to 112 500 2500 360×270×320
ERZE11E201 to 271 1000 5000 360×310×320
ERZE11E331 to 511 1000 5000 360×310×320
ERZE11E561 to 112 500 2500 360×270×320
ERZE05F201 to 471 1000 10000 400×360×260
ERZE07F201 to 271 1000 10000 400×360×260
ERZE07F331 to 471 1000 10000 470×360×260
ERZE07F511 to 621 500 5000 400×360×260
ERZE08F201 to 271 1000 5000 360×310×320
ERZE08F331 to 431 1000 5000 360×310×320
ERZE08F471 to 511 1000 5000 360×310×320
Crimped lead
ERZE08F561 to 751 500 2500 360×270×320
and taped
ERZE10F201 to 241 1000 5000 360×310×320
ERZE10F271 to 471 1000 5000 360×310×320
ERZE10F511 to 561 1000 5000 360×310×320
ERZE10F621 to 112 500 2500 360×270×320
ERZE11F201 to 271 1000 5000 360×310×320
ERZE11F331 to 511 1000 5000 360×310×320
ERZE11F561 to 112 500 2500 360×270×320
Part No., quantity and country of origin are designated on outer packages in English.
※Please contact local sales office about packing specifications.
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 27-Jan-23
30
Varistors (ZNR Surge Absorber)
D type
E-S1 series
Features
●Large withstanding surge current capability in compact sizes
●Withstanding surge current at max. 125 °C
●Large “Energy Handling Capability” absorbing transient overvoltages in compact sizes
●Wide range of varistor voltages
●RoHS compliant
Recommended applications
●Transistor, diode, IC, thyristor or triac semiconductor protection
●Surge protection in consumer electronic equipment
●Surge protection in communication, measuring or controller electronics
●Surge protection in electronic home appliances, gas or petroleum appliances
Applicable standards
●UL1449 (VZCA2/UL, VZCA8/C-UL)
●VDE IEC61051-1,-2,-2-2,IEC60950-1 Annex.Q,IEC62368-1 G8.2
●CQC (GB/T10193, GB/T10194, GB4943.1, GB8898)
Refer to "Standard Products" , and "Application Note for Safety Standards" , for the details.
E R Z E A S 1
Product code
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
31
D type / E11-S1 series
Reference guide to standard products
Varistor Clamping Maximum
Applicable Maximum
Voltage Voltage Peak Current
Standards Allowable Voltage
Part No. at 1 mA at 8/20 μs at 8/20 μs (A)
Type ACrms DC max. lp 85℃ 125℃ 125℃
Approvals (V)
name (V) (V) (V) (A) 1 time 1time 2 times
200
ERZE11A201S1 E11201 ○☆★◇◆ 130 170 340 50 6000 5000 4500
(185 to 225)
220
ERZE11A221S1 E11221 ○☆★◇◆ 140 180 360 50 6000 5000 4500
(198 to 242)
240
ERZE11A241S1 E11241 ○☆★◇◆ 150 200 395 50 6000 5000 4500
(216 to 264)
270
ERZE11A271S1 E11271 ○☆★◇◆ 175 225 455 50 6000 5000 4500
(247 to 303)
330
ERZE11A331S1 E11331 ○☆★◇◆ 210 270 545 50 6000 5000 4500
(297 to 363)
360
ERZE11A361S1 E11361 ○☆★◇◆ 230 300 595 50 6000 5000 4500
(324 to 396)
390
ERZE11A391S1 E11391 ○☆★◇◆ 250 320 650 50 6000 5000 4500
(351 to 429)
430
ERZE11A431S1 E11431 ○☆★◇◆ 275 350 710 50 6000 5000 4500
(387 to 473)
470
ERZE11A471S1 E11471 ○☆★◇◆ 300 385 775 50 6000 5000 4500
(423 to 517)
510
ERZE11A511S1 E11511 ○☆★◇◆ 320 410 845 50 6000 5000 4500
(459 to 561)
560
ERZE11A561S1 E11561 ○☆★◇◆ 350 450 930 50 6000 5000 4500
(504 to 616)
620
ERZE11A621S1 E11621 ○☆★◇◆ 385 505 1025 50 5000 5000 4500
(558 to 682)
680
ERZE11A681S1 E11681 ○☆★◇◆ 420 560 1120 50 5000 5000 4500
(612 to 748)
750
ERZE11A751S1 E11751 ○☆★◇◆ 460 615 1240 50 5000 5000 4500
(675 to 825)
820
ERZE11A821S1 E11821 ○☆★◇◆ 510 670 1355 50 5000 5000 4500
(738 to 902)
910
ERZE11A911S1 E11911 ○☆★◇◆ 550 745 1500 50 5000 5000 4500
(819 to 1001)
1000
ERZE11A102S1 E11102 ○☆★◇◆ 625 825 1650 50 5000 5000 4500
(900 to 1100)
1100
ERZE11A112S1 E11112 ○☆★◇◆ 680 895 1815 50 5000 5000 4500
(990 to 1210)
Maximum Allowable Voltage and Maximum Peak Current at 8/20 μs(A) at 125 °C
○ : UL1449 (VZCA2/UL, VZC A8/C-UL), ☆ : VDE (IEC61051-1, -2, -2-2), ★ : VDE (IEC60950-1 Annex.Q,IEC62368-1 G8.2),
◇ : CQC (GB/T10193, GB/T10194), ◆ : CQC (GB4943.1, GB8898)
※Approval number (File No.) of safety regulations are subject to revision without notice. Ask factory for a copy of the latest file No.
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
32
D type / E11-S1 series
Ratings and characteristics
●Operating temperature range : ‒40 to 125 ℃ ●Storage temperature range : ‒40 to 125 ℃
ACrms DC
(V) (V) (W) (J) (J) (A) (A) (A) (pF)
(V) (V)
ERZE11A201S1 200(185 to 225) 130 170 340 0.6 70 50 6000 5000 4500 690
ERZE11A221S1 220(198 to 242) 140 180 360 0.6 78 55 6000 5000 4500 660
ERZE11A241S1 240(216 to 264) 150 200 395 0.6 84 60 6000 5000 4500 620
ERZE11A271S1 270(247 to 303) 175 225 455 0.6 99 70 6000 5000 4500 580
ERZE11A331S1 330(297 to 363) 210 270 545 0.6 115 80 6000 5000 4500 520
ERZE11A361S1 360(324 to 396) 230 300 595 0.6 130 90 6000 5000 4500 480
ERZE11A391S1 390(351 to 429) 250 320 650 0.6 140 100 6000 5000 4500 450
ERZE11A431S1 430(387 to 473) 275 350 710 0.6 155 110 6000 5000 4500 400
ERZE11A471S1 470(423 to 517) 300 385 775 0.6 175 125 6000 5000 4500 360
ERZE11A511S1 510(459 to 561) 320 410 845 0.6 190 136 6000 5000 4500 310
ERZE11A561S1 560(504 to 616) 350 450 930 0.6 190 136 6000 5000 4500 310
ERZE11A621S1 620(558 to 682) 385 505 1025 0.6 190 136 5000 5000 4500 300
ERZE11A681S1 680(612 to 748) 420 560 1120 0.6 190 136 5000 5000 4500 290
ERZE11A751S1 750(675 to 825) 460 615 1240 0.6 210 150 5000 5000 4500 280
ERZE11A821S1 820(738 to 902) 510 670 1355 0.6 235 165 5000 5000 4500 260
ERZE11A911S1 910(819 to 1001) 550 745 1500 0.6 255 180 5000 5000 4500 240
ERZE11A102S1 1000(900 to 1100) 625 825 1650 0.6 280 200 5000 5000 4500 220
ERZE11A112S1 1100(990 to 1210) 680 895 1815 0.6 310 220 5000 5000 4500 200
✽Ip Measuring current of clamping voltage : 50 A
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
33
D type / E11-S1 series
Typical characteristics
Voltage vs. Current Impulse Derating (Relation between
impulse width and impulse current multiple)
511
471
431
471 391
361
431
1000 391
331
271
900 361 241 1000
800 221
201
700
600
500
Impulse Current(A)
400
Voltage(V)
300 100
200
100
331
90 10
221
80
70
60
Test current waveform
50 10–6 to 10–3 A: Direct current
10–1 to 104 A: 8/20 μs
40
30
10-6 10-5 10-4 10-3 10-2 10-1 100 101 102 103 104 105 120
100 1000 10000
3000
112
102
911
821 1000
2000 751
681
102 621
561
Impulse Current(A)
911
821
Voltage(V)
1000 100
900
800
700
600
500
10
400
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
34
D type / E14-S1 series
Reference guide to standard products
Varistor Clamping Maximum
Applicable Maximum
voltage voltage peak current
standards allowable voltage
Part No. at 1 mA at 8/20 μs at 8/20 μs (A)
Type ACrms DC max. lp 85℃ 125℃ 125℃
Approvals (V)
name (V) (V) (V) (A) 1 time 1time 2 times
200
ERZE14A201S1 E14201 ○☆★◇◆ 130 170 340 100 10000 7500 6500
(185 to 225)
220
ERZE14A221S1 E14221 ○☆★◇◆ 140 180 360 100 10000 7500 6500
(198 to 242)
240
ERZE14A241S1 E14241 ○☆★◇◆ 150 200 395 100 10000 7500 6500
(216 to 264)
270
ERZE14A271S1 E14271 ○☆★◇◆ 175 225 455 100 10000 7500 6500
(247 to 303)
330
ERZE14A331S1 E14331 ○☆★◇◆ 210 270 545 100 10000 7500 6500
(297 to 363)
360
ERZE14A361S1 E14361 ○☆★◇◆ 230 300 595 100 10000 7500 6500
(324 to 396)
390
ERZE14A391S1 E14391 ○☆★◇◆ 250 320 650 100 10000 7500 6500
(351 to 429)
430
ERZE14A431S1 E14431 ○☆★◇◆ 275 350 710 100 10000 7500 6500
(387 to 473)
470
ERZE14A471S1 E14471 ○☆★◇◆ 300 385 775 100 10000 7500 6500
(423 to 517)
510
ERZE14A511S1 E14511 ○☆★◇◆ 320 410 845 100 10000 7500 6500
(459 to 561)
560
ERZE14A561S1 E14561 ○☆★◇◆ 350 450 930 100 10000 7500 6500
(504 to 616)
620
ERZE14A621S1 E14621 ○☆★◇◆ 385 505 1025 100 7500 7500 6500
(558 to 682)
680
ERZE14A681S1 E14681 ○☆★◇◆ 420 560 1120 100 7500 7500 6500
(612 to 748)
750
ERZE14A751S1 E14751 ○☆★◇◆ 460 615 1240 100 7500 7500 6500
(675 to 825)
820
ERZE14A821S1 E14821 ○☆★◇◆ 510 670 1355 100 7500 7500 6500
(738 to 902)
910
ERZE14A911S1 E14911 ○☆★◇◆ 550 745 1500 100 7500 7500 6500
(819 to 1001)
1000
ERZE14A102S1 E14102 ○☆★◇◆ 625 825 1650 100 7500 7500 6500
(900 to 1100)
1100
ERZE14A112S1 E14112 ○☆★◇◆ 680 895 1815 100 7500 7500 6500
(990 to 1210)
Maximum Allowable Voltage and Maximum Peak Current at 8/20 μs(A) at 125 °C
○ : UL1449 (VZCA2/UL, VZC A8/C-UL), ☆ : VDE (IEC61051-1, -2, -2-2), ★ : VDE (IEC60950-1 Annex.Q,IEC62368-1 G8.2),
◇ : CQC (GB/T10193, GB/T10194), ◆ : CQC (GB4943.1, GB8898)
※Approval number (File No.) of safety regulations are subject to revision without notice. Ask factory for a copy of the latest file No.
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
35
D type / E14-S1 series
Ratings and characteristics
●Operating temperature range : ‒40 to 125 ℃ ●Storage temperature range : ‒40 to 125 ℃
Clamping Maximum peak current
Varistor Maximum Maximum energy
voltage Rated at 8/20 μs Capacitance
voltage allowable (max.)
(max.) power
Part No. at 1 mA voltage 10/1000
2 ms
85 ℃ 125 ℃ 125 ℃ 2 at 1 kHz
*lp μs 1 time 1time times
ACrms DC
(V) (V) (W) (J) (J) (A) (A) (A) (pF)
(V) (V)
ERZE14A201S1 200(185 to 225) 130 170 340 1.0 140 100 10000 7500 6500 1300
ERZE14A221S1 220(198 to 242) 140 180 360 1.0 155 110 10000 7500 6500 1200
ERZE14A241S1 240(216 to 264) 150 200 395 1.0 168 120 10000 7500 6500 1100
ERZE14A271S1 270(247 to 303) 175 225 455 1.0 190 135 10000 7500 6500 1000
ERZE14A331S1 330(297 to 363) 210 270 545 1.0 228 160 10000 7500 6500 900
ERZE14A361S1 360(324 to 396) 230 300 595 1.0 255 180 10000 7500 6500 900
ERZE14A391S1 390(351 to 429) 250 320 650 1.0 275 195 10000 7500 6500 800
ERZE14A431S1 430(387 to 473) 275 350 710 1.0 303 215 10000 7500 6500 800
ERZE14A471S1 470(423 to 517) 300 385 775 1.0 350 250 10000 7500 6500 750
ERZE14A511S1 510(459 to 561) 320 410 845 1.0 382 273 10000 7500 6500 700
ERZE14A561S1 560(504 to 616) 350 450 930 1.0 382 273 10000 7500 6500 700
ERZE14A621S1 620(558 to 682) 385 505 1025 1.0 382 273 7500 7500 6500 650
ERZE14A681S1 680(612 to 748) 420 560 1120 1.0 382 273 7500 7500 6500 600
ERZE14A751S1 750(675 to 825) 460 615 1240 1.0 420 300 7500 7500 6500 530
ERZE14A821S1 820(738 to 902) 510 670 1355 1.0 460 325 7500 7500 6500 500
ERZE14A911S1 910(819 to 1001) 550 745 1500 1.0 510 360 7500 7500 6500 400
ERZE14A102S1 1000(900 to 1100) 625 825 1650 1.0 565 400 7500 7500 6500 400
ERZE14A112S1 1100(990 to 1210) 680 895 1815 1.0 620 440 7500 7500 6500 350
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
36
D type / E14-S1 series
Typical characteristics
Voltage vs. Current Impulse Derating (Relation between
impulse width and impulse current multiple)
471
471 431
431 391
391 361
1000 361 331
1000
900 271
800 241
700 221
201
600
500
100
300
200
100 10
90
80
241
70 331
221
60
50 Test current waveform
10–6 to 10–3 A: Direct current
10–1 to 104 A: 8/20 μs
40
30 1
10-6 10-5 10-4 10-3 10-2 10-1 100 101 102 103 104 105 20 100 1000 10000
5000 10000
Max.Leakage
Current Max.Clamping Voltage 2 times:5 min. interval
4000 up to 10 times:2 min. interval
up to 106 times : 10 sec. interval
3000 112
102
911
821
1000
751
2000
681
621
561
102
Impulse Current (A)
911
Voltage(V)
821
1000 100
900
800
700
600
500
10
400
300
751 Test current waveform
681 10–6 to 10–3 A: Direct current
10–1 to 104 A: 8/20 μs
621
200 1
10-6 10-5 10-4 10-3 10-2 10-1 100 101 102 103 104 105 20 100 1000 10000
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
37
D type / E-S1 series (Leads cut type)
Straight leads cut type (Bulk type)
※ Ratings and characteristics is refer to bulk standard type.
ød
B
F L*
Unit : mm
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
38
D type / E-S1 series
Application Note for Safety Standards (For Series E-S1)
● Approvals products lists in "Reference Guide to Standard Products."
● UL and VDE : Registered in "Type name", it isn’t registered in "Panasonic Part No."
● CQC : Registered in "Panasonic Part No."
● "Rated Voltages" are specified for UL recognized components in list shown below.
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
39
D type / E-S1 series
Explanation of the contents
Mark Explanation of the content
Abbreviation of
E11□□□ □□□
Part No.
E14□□□ (Type name) Nominal varistor volage
*1: If the 10's digit of a Christian year is an even year, as an end abbreviation,
an alphabetic character is used.
1 : A, 2 : B, 3 : C, 4 : D, 5 : E, 6 : F, 7 : G, 8 : H, 9 : J, 0 : K
If the 10's digit of a Christian year is an odd year, as an end abbreviation, a
number is used.
Marking contents
Series (Example)
Varister
11 14
voltage (ERZE11A□□□S1) (ERZE14A□□□S1)
ZNR ZNR
201 or more E11□□□ E14□□□
○◆◇H ○◆◇H
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
40
D type / E-S1 series
Performance characteristics
Characteristics Test methods / description Specifications
Maximum The maximum sinusoidal RMS voltage or maximum DC voltage that can be applied
allowable voltage continuously. (max. 125 ℃)
100
90
Current (%)
Clamping voltage
50
To meet the
10
specified value.
0
8 μs Time
20 μs
Rated power The power that can be applied in the specified ambient temperature.
The maximum energy within the varistor voltage change of ±10 % when a single
Maximum energy
impulse current of 2 ms or 10/1000 μs is applied.
The maximum current within the varistor voltage change of ±10 % when a standard
Maximum 2times impulse current of 8/20 μs is applied two times with an interval of 5 minutes. (at max.
peak current 125 ℃)
(Withstanding
Electrical
surge The maximum current within the varistor voltage change of ±10 % with a single
current) 1time
standard impulse current of 8/20 μs is applied. (at max. 125 ℃)
Withstanding voltage AC 1500 Vrms shall be applied between both terminals of the specimen connected
No breakdown
(Body Insulation) together and metal foil closely wrapped round its body for 1 minute.
The change of VC shall be measured after the impulse current listed below is applied
10000 or 100000 times continuously with the interval of 10 seconds at room
temperature.
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
41
D type / E-S1 series
Performance characteristics
Characteristics Test methods / description Specifications
After gradually applying the force specified below and keeping the unit fixed for 10
seconds, the terminal shall be visually examined for any damage.
Robustness of
terminations Terminal diameter Force
(Tensile) ø0.6 mm, ø0.8 mm 9.8 N
ø1.0 mm 19.6 N
The unit shall be secured with its terminal kept vertical and the force specified below
shall be applied in the axial direction. The terminal shall gradually be bent by 90 ° in
one direction, then 90 ° in the opposite direction, and again back to the original No remarkable mechanical
Robustness of position. The damage of the terminal shall be visually examined. damage
terminations
(Bending)
Terminal diameter Force
Mechanical
After repeadly applying a single harmonic vibration (amplitude: 0.75 mm, double
amplitude: 1.5 mm) with 1 minute vibration frequency cycles (10 Hz to 55 Hz to 10 Hz)
Vibration
to each of three perpendicular directions for 2 hours. Thereafter, the unit shall be
visually examined.
Approximately 95 %
After dipping the terminals to a depth of approximately 3 mm from the body in a of the termainals shall
Solderability
soldering bath of 235±5 ℃ for 2±0.5 seconds, the terminal shall be visually examined. be covered with new
solder uniformly.
After each lead shall be dipped into a solder bath having a temperature
of 260±5 ℃ to a point 2.0 to 2.5 mm from the body of the unit, using
Resistance to
shielding board (t=1.5 mm), be held there for 10±1 s and then be stored ΔV1 mA/V1 mA ≦ ±5 %
soldering heat
at room temperature and normal humidity for 1 to 2 hours. The change of
VCmA and mechanical damages shall be examined.
The specimen shall be subjected to 125±2 ℃ for 1000 hours in a thermostatic bath
High temperature
without load and then stored at room temperature and normal humidity for 1 to 2 hours. ΔV1 mA/V1 mA ≦ ±5 %
storage/Dry heat
Thereafter, the change of VCmA shall be measured.
After being continuously applied the Maximum Allowable Voltage at 125±2 ℃ for 1000
High temperature
hours, the specimen shall be stored at room temperature and normal humidity for 1 to 2
load/Dry heat load
hours. Thereafter, the change of VCmA shall be measured.
ΔV1 mA/V1 mA ≦ ±10 %
The specimen shall be subjected to 40±2 ℃, 90 to 95 % RH and the
Damp heat load/ Maximum Allowable Voltage for 1000 hours and then stored at room
humidity load temperature and normal humidity for 1 to 2 hours. Thereafter, the change of VCmA
shall be measured.
The specimen shall be subjected to –40±2 ℃ without load for 1000 hours and then
Low temperature
stored at room temperature and normal humidity for 1 to 2 hours. Thereafter, the ΔV1 mA/V1 mA ≦ ±5 %
storage/Cold
change of VCmA shall be measured.
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
42
D type / E-S1 series
Minimum quantity / Packing unit
Minimum
Packing quantity Carton (about)
Product Series / Type Part number quantity
/ Packing unit
in carton L×W×H (mm)
Part No., quantity and country of origin are designated on outer packages in English.
※Please contact local sales office about packing specifications.
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
43
Matters to Be Observed When Using This Product
Safety measures
An abnormal state for varistors (ZNR surge absorbers) of the D type/V series and SMD-Type/HF, VF Series (hereinafter
the product or "the surge absorber") that results from a problem with service conditions (materials used, the surrounding
environment, power conditions, circuit conditions, etc.) may cause a fire accident, electric shock accident, burn accident,
or product failure. Matters to note when handling this product will hereinafter be described. What is described below should
be checked sufficiently before the product is used.
■ Take the following measures in order to avoid an accident caused by expected phenomenon.
(1) Destruction of the surge absorber may scatter its fractured pieces around. To protect other elements from these
pieces, set product in a case or shield it with a cover.
(2) Do not place the surge absorber near combustible materials (vinyl cable, resin mold, etc.). If avoiding the vicinity
of combustible materials is difficult, protect the combustible material with an incombustible cover.
(3) Surge absorber placed between lines
When the surge absorber is placed between lines, connect a normal type current fuse in series with the surge
absorber.
* See "Current fuse" in the "Circuit design and circuit board design" section.
(4) Surge absorber placed between a line and the ground
① When the surge absorber is placed between a line and the ground, even if the surge absorber short-circuits,
ground resistance will remain in the section between the line and the ground, leaving a possibility that the
current fuse won’t blow, in which case the outer sheath resin of the surge absorber may generate smoke or
ignite due to current flow. To prevent such a case, place an earth leakage breaker in a location closer to the
power supply than the surge absorber. When not using an earth leakage breaker, use a current fuse and
temperature fuse in series with each other.
* See Table 1 in the "Circuit design and circuit board design" section.
② When the surge absorber is placed between a live part and a metal case, it may cause electric shock if the
surge absorber short-circuits. To avoid this, ground the metal case or shield it to prevent direct contact with the
metal case.
■ In case the surge absorber should short-circuit and generate smoke or ignite, immediately cut off current flow
to the surge absorber.
■ An unexpected sharp rise in the working voltage, an incoming excessive surge, etc., may cause the surge absorber to
generate smoke or ignite.
In such a case, fire spreading through the device should be prevented to avoid expanded damage. To achieve this,
take a multi-protection measure, such as adopting fire-resistant materials that make up the outer shell components
and structural materials.
30-Jun-23
44
Matters to Be Observed When Using This Product
■ Do not use the surge absorber in which direct sunlight hits the surge absorber or near a heating element where the
temperature of the surge absorber would rise above its working temperature.
■ Do not use the surge absorber in a place where the surge absorber is exposed to wind or rain or a highly humid place
where steam is emitted or dew concentrates.
■ Do not use the surge absorber in a place filled with dust or salt, in an atmosphere contaminated with a corrosive gas,
etc., or in liquids such as water, oil, chemical, or organic solvents.
■ Do not wash the surge absorber with a solvent (thinner, acetone, etc.) that damages the outer sheath resin.
Reliability
A capacitor conforming to "AEC-Q200" refers to a capacitor having passed some or all of evaluation test items defined
in AEC-Q200.
To know the detailed specifications of each capacitor or specific evaluation test scores, please contact us.
We issue a delivery specification sheet for each product ordered. Please confirm the delivery specification sheet when
you place an order with us.
■ Choose a surge absorber whose maximum allowable circuit voltage has a margin relative to the maximum voltage range
including source voltage fluctuations.
* See Table 1 in the "Circuit design and circuit board design" section.
■ When surges are applied intermittently to the surge absorber at short intervals (when pulses of voltages are applied in a
noise simulator test, etc.), make sure that the surge power does not exceed the maximum average pulse power of the surge
absorber.
■ The product numbers of recommended surge absorbers to choose are shown in Table 1.
30-Jun-23
45
Matters to Be Observed When Using This Product
■ Current fuse
(1) Select a surge absorber and the rated current for a current fuse to be used in a manner shown in the following table.
Confirm that no secondary accident arises when the surge absorber in an actual circuit breaks. Selected rated currents
of current fuses shown in the following table are exemplary one and may vary depending on circuit conditions used.
Confirm the rated current by a test, etc., before using the current fuse.
<Rated currents of current fuses for the D-type / V series surge absorber>
Standard
product number ERZV05D□□□ ERZV07D□□□ ERZV09D□□□ ERZV10D□□□ ERZV14D□□□ ERZV20D□□□
Rating
current
3 A max. 5 A max. 7 A max. 7 A max. 10 A max. 10 A max.
* Use the rated voltage of the current fuse that corresponds to the circuit voltage of a circuit including the current fuse.
<Rated current of a current fuse for the SMD-type / VF series surge absorber>
Standard
product number
ERZVF□M□□□
Rating current 5 A max.
* Use the rated voltage of the current fuse that corresponds to the circuit voltage of a circuit including the current fuse.
* For the HF series surge absorber, select the rated current of the fuse after confirming the way the fuse handles a load dump
surge and the protective coordination action it makes when the surge absorber is destroyed.
(2) Recommended parts where fuses are connected are shown in Table 1. When a load current to a protected device is so
large as to exceed the rated current of the fuse, however, connect the fuse in a location shown in the following diagram.
Current fuse
Power supply Protected
device
ZNR
■ Temperature fuse
When connecting the surge absorber to a temperature fuse, choose a connection method and a temperature fuse that allow
fine thermal coupling between the surge absorber and the temperature fuse.
30-Jun-23
46
Matters to Be Observed When Using This Product
DC DC
Single-phase AC Single-phase AC
Current fuse ZNR1
Current fuse ZNR1 L
L
Protected
device
Protected N
device ZNR2
N
Three-phase AC Three-phase AC
Current fuse
Current fuse ZNR3 ZNR3
ZNR3
Protected
Protected device
ZNR3
device
ZNR4
ZNR3
Thermal coupling Temperature fuse
Power supply Nominal varistor voltage Power supply Nominal varistor voltage
ZNR voltage ZNR voltage
[AC] D-type SMD-type [AC] D-type SMD-type
100 V 201 to 361* 201 to 361* 471 471
Varistor voltage selection
Processing conditions
■ Do not apply vibration, impact (drop impact, etc.), or pressure strong enough to crack the outer sheath resin or absorber
body of the surge absorber.
■ When coating the surge absorber with a resin or embedding it in a resin mold, avoid using a resin that degrades the
surge absorber.
■ Do not bend or apply a force to the lead of a D-type surge absorber close to the outer sheath resin.
30-Jun-23
47
Matters to Be Observed When Using This Product
■ When making holes for mounting the surge absorber on the board, check the dimensions of the holes on the board,
referencing the central point of the interval between the leads.
Because the overall dimensional tolerance is large, forming the holes with high precision requires careful processing.
Flow soldering The D-type surge absorber should not be soldered by reflow
D-type 260 ℃, 10 seconds or less
(solder bath immersion method) soldering.
A high component mounting density may lead to poor
Flow soldering
260 ℃, 10 seconds or less solderability. In such a case, consider vent hole formation.
(solder bath immersion method)
SMD-type
Reflow soldering Refer to the recommended When a land is excessively larger than the terminal surface of
(controlled atmosphere heating soldering temperature a component, the component may shift position when solder is
method) profile. melted.
Note 1: Soldering the surge absorber under soldering conditions different from the recommended soldering
conditions requires extra checking to ensure it won’t cause any problems.
Additional soldering is allowed only once. It must be done within 5 seconds, with the soldering iron
temperature kept at 400 ℃ or lower.
Note 2: A temperature profile may include a large error, depending on the measurement method used.
Be careful in such cases.
Note 3: Board temperatures vary depending on the sizes of boards and mounting densities. Confirm the
temperature for each type of board.
Heat resistance range of the
product in the reflow soldering
<Recommended soldering temperature profile>
process
260
Flow soldering Reflow soldering
(solder bath immersion method) (controlled atmosphere heating method) 250
Temperature (°C)
Terminal temperature (°C)
Soldering part
Preheating part Cooling part Cooling part 240
Temperature (°C)
Preheating part
230
220
210
Temperature-rising part (II)
Soldering part 260 ℃ or less 10 seconds or less Preheating part 150 ℃ to 180 ℃ 60 to 120 seconds
■ Do not keep the product in a high-temperature or high-humidity condition. Keep the surge absorber in a room with
a temperature of 40 ℃ or lower and a relative humidity of 75% or lower and use the surge absorber within two years of
storage. Check the solderability of a surge absorber stored for a long period (two years or more) before using the surge
absorber.
■ Keep the surge absorber in a place where no corrosive gas atmosphere (hydrogen sulfide, sulfurous acid, chlorine,
ammonia, etc.) is present.
■ Keep the surge absorber in a place where the surge absorber is protected from direct sunlight, dew concentration, etc.
30-Jun-23
48
Varistors (ZNR Surge Absorber)
D type
V series For Varistor Voltages ranging from 200 to 1100V, kindly also consider corresponding, smaller E
Series devices with better performance for their size. → Please click here
Features
●Large withstanding surge current capability in compact sizes
●Large “Energy Handling Capability” absorbing transient overvoltages in compact sizes
●Wide range of varistor voltages
●RoHS compliant
Recommended applications
●Transistor, diode, IC, thyristor or triac semiconductor protection
●Surge protection in consumer electronic equipment
●Surge protection in communication, measuring or controller electronics
●Surge protection in electronic home appliances, gas or petroleum appliances
Applicable standards
●UL1449 (VZCA2/UL, VZCA8/C-UL)
●VDE IEC61051-1,-2,-2-2,IEC60950-1 Annex.Q, IEC62368-1 G8.2
●CSA C22.2 N 269.5
●CQC (GB/T10193, GB/T10194, GB4943.1, GB8898)
Refer to "Standard Products" , and "Application Note for Safety Standards" , for the details.
E R Z V D
Product code Series Design No.
E R Z V D
Product code Series Design No.
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 23-Dec-21
49
D type / V series
Reference guide to standard products
Maximum
Applicable Varistor Maximum Clamping
peak current
Part No. standards voltage* allowable voltage voltage 8/20 μs
at 8/20 μs (A)
Type name Approvals (V) AC rms (V) DC (V) max.(V) lp (A) 1 time 2 times
ERZV05D180 V180 ◇ 40 1 250 125
ERZV07D180 V7180 ◇ 36 2.5 500 250
ERZV09D180 V9180 ◇ 18 36 5 1000 500
11 14
ERZV10D180 V10180 ◇ (16 to 20) 36 5 1000 500
ERZV14D180 V14180 ◇ 36 10 2000 1000
ERZV20D180 V20180 ◇ 36 20 3000 2000
ERZV05D220 V220 ◇ 48 1 250 125
ERZV07D220 V7220 ◇ 43 2.5 500 250
ERZV09D220 V9220 ◇ 22 43 5 1000 500
14 18
ERZV10D220 V10220 ◇ (20 to 24) 43 5 1000 500
ERZV14D220 V14220 ◇ 43 10 2000 1000
ERZV20D220 V20220 ◇ 43 20 3000 2000
ERZV05D270 V270 ◇ 60 1 250 125
ERZV07D270 V7270 ◇ 53 2.5 500 250
ERZV09D270 V9270 ◇ 27 53 5 1000 500
17 22
ERZV10D270 V10270 ◇ (24 to 30) 53 5 1000 500
ERZV14D270 V14270 ◇ 53 10 2000 1000
ERZV20D270 V20270 ◇ 53 20 3000 2000
ERZV05D330 V330 ◇ 73 1 250 125
ERZV07D330 V7330 ◇ 65 2.5 500 250
ERZV09D330 V9330 ◇ 33 65 5 1000 500
20 26
ERZV10D330 V10330 ◇ (30 to 36) 65 5 1000 500
ERZV14D330 V14330 ◇ 65 10 2000 1000
ERZV20D330 V20330 ◇ 65 20 3000 2000
ERZV05D390 V390 ◇ 86 1 250 125
ERZV07D390 V7390 ◇ 77 2.5 500 250
ERZV09D390 V9390 ◇ 39 77 5 1000 500
25 31
ERZV10D390 V10390 ◇ (35 to 43) 77 5 1000 500
ERZV14D390 V14390 ◇ 77 10 2000 1000
ERZV20D390 V20390 ◇ 77 20 3000 2000
ERZV05D470 V470 ◇ 104 1 250 125
ERZV07D470 V7470 ◇ 93 2.5 500 250
ERZV09D470 V9470 ◇ 47 93 5 1000 500
30
ERZV10D470 V10470 ◇ (42 to 52) 38 93 5 1000 500
ERZV14D470 V14470 ◇ 93 10 2000 1000
ERZV20D470 V20470 ◇ 93 20 3000 2000
ERZV05D560 V560 ◇ 123 1 250 125
ERZV07D560 V7560 ◇ 110 2.5 500 250
ERZV09D560 V9560 ◇ 56 110 5 1000 500
35 45
ERZV10D560 V10560 ◇ (50 to 62) 110 5 1000 500
ERZV14D560 V14560 ◇ 110 10 2000 1000
ERZV20D560 V20560 ◇ 110 20 3000 2000
ERZV05D680 V680 ◇ 150 1 250 125
ERZV07D680 V7680 ◇ 135 2.5 500 250
ERZV09D680 V9680 ◇ 68 135 5 1000 500
40 56
ERZV10D680 V10680 ◇ (61 to 75) 135 5 1000 500
ERZV14D680 V14680 ◇ 135 10 2000 1000
ERZV20D680 V20680 ◇ 135 20 3000 2000
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 23-Dec-21
50
D type / V series
Reference guide to standard products
Maximum
Applicable Varistor Maximum Clamping
peak current
Part No. standards voltage* allowable voltage voltage 8/20 μs
at 8/20 μs (A)
Type name Approvals (V) AC rms (V) DC (V) max.(V) lp (A) 1 time 2 times
ERZV05D820 V820U ○☆◇ 145 5 800 600
ERZV07D820 V7820U ○☆◇ 135 10 1750 1250
ERZV09D820 V9820U ○☆◇ 82 135 25 3500 2500
50 65
ERZV10D820 V10820U ○☆◇ (74 to 90) 135 25 3500 2500
ERZV14D820 V14820U ○☆◇ 135 50 6000 5000
ERZV20D820 V20820U ○☆◇ 135 100 10000 7000
ERZV05D101 V101U ○☆◇ 175 5 800 600
ERZV07D101 V7101U ○☆◇ 165 10 1750 1250
ERZV09D101 V9101U ○☆◇ 100 165 25 3500 2500
60 85
ERZV10D101 V10101U ○☆◇ (90 to 110) 165 25 3500 2500
ERZV14D101 V14101U ○☆◇ 165 50 6000 5000
ERZV20D101 V20101U ○☆◇ 165 100 10000 7000
ERZV05D121 V121U ○☆◇ 210 5 800 600
ERZV07D121 V7121U ○☆◇ 200 10 1750 1250
ERZV09D121 V9121U ○☆◇ 120 200 25 3500 2500
75 100
ERZV10D121 V10121U ○☆◇ (108 to 132) 200 25 3500 2500
ERZV14D121 V14121U ○☆◇ 200 50 6000 5000
ERZV20D121 V20121U ○☆◇ 200 100 10000 7000
ERZV05D151 V151U ○☆◇ 260 5 800 600
ERZV07D151 V7151U ○☆◇ 250 10 1750 1250
ERZV09D151 V9151U ○☆◇ 150 250 25 3500 2500
95 125
ERZV10D151 V10151U ○☆◇ (135 to 165) 250 25 3500 2500
ERZV14D151 V14151U ○☆◇ 250 50 6000 5000
ERZV20D151 V20151U ○☆◇ 250 100 10000 7000
ERZV05D201 V201U ○☆□◇ 355 5 800 600
ERZV07D201 V7201U ○☆□◇ 340 10 1750 1250
ERZV09D201 V9201U ○☆□◇ 200 340 25 3500 2500
130 170
ERZV10D201 V10201U ○☆□◇ (185 to 225) 340 25 3500 2500
ERZV14D201 V14201U ○☆★□◇◆ 340 50 6000 5000
ERZV20D201 V20201U ○☆★□◇◆ 340 100 10000 7000
ERZV05D221 V221U ○☆□◇ 380 5 800 600
ERZV07D221 V7221U ○☆□◇ 360 10 1750 1250
ERZV09D221 V9221U ○☆□◇ 220 360 25 3500 2500
140 180
ERZV10D221 V10221U ○☆□◇ (198 to 242) 360 25 3500 2500
ERZV14D221 V14221U ○☆★□◇◆ 360 50 6000 5000
ERZV20D221 V20221U ○☆★□◇◆ 360 100 10000 7000
ERZV05D241 V241U ○☆□◇ 415 5 800 600
ERZV07D241 V7241U ○☆□◇ 395 10 1750 1250
ERZV09D241 V9241U ○☆□◇ 240 395 25 3500 2500
150 200
ERZV10D241 V10241U ○☆□◇ (216 to 264) 395 25 3500 2500
ERZV14D241 V14241U ○☆★□◇◆ 395 50 6000 5000
ERZV20D241 V20241U ○☆★□◇◆ 395 100 10000 7000
ERZV05D271 V271U ○☆□◇ 475 5 800 600
ERZV07D271 V7271U ○☆□◇ 455 10 1750 1250
ERZV09D271 V9271U ○☆□◇ 270 455 25 3500 2500
175 225
ERZV10D271 V10271U ○☆□◇ (247 to 303) 455 25 3500 2500
ERZV14D271 V14271U ○☆★□◇◆ 455 50 6000 5000
ERZV20D271 V20271U ○☆★□◇◆ 455 100 10000 7000
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 23-Dec-21
51
D type / V series
Reference guide to standard products
Maximum
Applicable Varistor Maximum Clamping
peak current
Part No. standards voltage* allowable voltage voltage 8/20 μs
at 8/20 μs (A)
Type name Approvals (V) AC rms (V) DC (V) max.(V) lp (A) 1 time 2 times
ERZV05D331 V331U ○☆□◇ 570 5 800 600
ERZV07D331 V7331U ○☆□◇ 545 10 1750 1250
ERZV09D331 V9331U ○☆□◇ 545 25 3500 2500
330 210 270
ERZV10D331 V10331U ○☆□◇ (297 to 363) 545 25 3500 2500
ERZV14D331 V14331U ○☆★□◇◆ 545 50 6000 4500
ERZV20D331 V20331U ○☆★□◇◆ 545 100 10000 6500
ERZV05D361 V361U ○☆□◇ 620 5 800 600
ERZV07D361 V7361U ○☆□◇ 595 10 1750 1250
ERZV09D361 V9361U ○☆□◇ 360 595 25 3500 2500
230 300
ERZV10D361 V10361U ○☆□◇ (324 to 396) 595 25 3500 2500
ERZV14D361 V14361U ○☆★□◇◆ 595 50 6000 4500
ERZV20D361 V20361U ○☆★□◇◆ 595 100 10000 6500
ERZV05D391 V391U ○☆□◇ 675 5 800 600
ERZV07D391 V7391U ○☆□◇ 650 10 1750 1250
ERZV09D391 V9391U ○☆□◇ 390 650 25 3500 2500
250 320
ERZV10D391 V10391U ○☆□◇ (351 to 429) 650 25 3500 2500
ERZV14D391 V14391U ○☆★□◇◆ 650 50 6000 4500
ERZV20D391 V20391U ○☆★□◇◆ 650 100 10000 6500
ERZV05D431 V431U ○☆□◇ 745 5 800 600
ERZV07D431 V7431U ○☆□◇ 710 10 1750 1250
ERZV09D431 V9431U ○☆□◇ 430 710 25 3500 2500
275 350
ERZV10D431 V10431U ○☆□◇ (387 to 473) 710 25 3500 2500
ERZV14D431 V14431U ○☆★□◇◆ 710 50 6000 4500
ERZV20D431 V20431U ○☆★□◇◆ 710 100 10000 6500
ERZV05D471 V471U ○☆□◇ 810 5 800 600
ERZV07D471 V7471U ○☆□◇ 775 10 1750 1250
ERZV09D471 V9471U ○☆□◇ 470 775 25 3500 2500
300 385
ERZV10D471 V10471U ○☆★□◇◆ (423 to 517) 775 25 3500 2500
ERZV14D471 V14471U ○☆★□◇◆ 775 50 6000 4500
ERZV20D471 V20471U ○☆★□◇◆ 775 100 10000 6500
ERZV07D511 V7511U ○☆□◇ 845 10 1750 1250
ERZV09D511 V9511U ○☆□◇ 845 25 3500 2500
510
ERZV10D511 V10511U ○☆★□◇◆ 320 410 845 25 3500 2500
(459 to 561)
ERZV14D511 V14511U ○☆★□◇◆ 845 50 6000 4500
ERZV20D511 V20511U ○☆★□◇◆ 845 100 10000 6500
ERZV10D561 V10561U ○☆★□◇◆ 930 25 3500 2500
560
ERZV14D561 V14561U ○☆★□◇◆ 350 450 930 50 5000 4500
(504 to 616)
ERZV20D561 V20561U ○☆★□◇◆ 930 100 7500 6500
ERZV10D621 V10621U ○☆★□◇◆ 1025 25 3500 2500
620
ERZV14D621 V14621U ○☆★□◇◆ 385 505 1025 50 5000 4500
(558 to 682)
ERZV20D621 V20621U ○☆★□◇◆ 1025 100 7500 6500
ERZV10D681 V10681U ○☆★□◇◆ 1120 25 3500 2500
680
ERZV14D681 V14681U ○☆★□◇◆ 420 560 1120 50 5000 4500
(612 to 748)
ERZV20D681 V20681U ○☆★□◇◆ 1120 100 7500 6500
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 23-Dec-21
52
D type / V series
Reference guide to standard products
Maximum
Applicable Varistor Maximum Clamping
peak current
Part No. standards voltage* allowable voltage voltage 8/20 μs
at 8/20 μs (A)
Type name Approvals (V) AC rms (V) DC (V) max.(V) lp (A) 1 time 2 times
ERZV10D751 V10751U ○☆★□◇◆ 1240 25 3500 2500
750
ERZV14D751 V14751U ○☆★□◇◆ 460 615 1240 50 5000 4500
(675 to 825)
ERZV20D751 V20751U ○☆★□◇◆ 1240 100 7500 6500
ERZV10D821 V10821U ○☆★□◇◆ 1355 25 3500 2500
820
ERZV14D821 V14821U ○☆★□◇◆ 510 670 1355 50 5000 4500
(738 to 902)
ERZV20D821 V20821U ○☆★□◇◆ 1355 100 7500 6500
ERZV10D911 V10911U ○☆★□◇◆ 1500 25 3500 2500
910
ERZV14D911 V14911U ○☆★□◇◆ 550 745 1500 50 5000 4500
(819 to 1001)
ERZV20D911 V20911U ○☆★□◇◆ 1500 100 7500 6500
ERZV10D102 V10102U ○☆★□◇◆ 1650 25 3500 2500
1000
ERZV14D102 V14102U ○☆★□◇◆ 625 825 1650 50 5000 4500
(900 to 1100)
ERZV20D102 V20102U ○☆★□◇◆ 1650 100 7500 6500
ERZV10D112 V10112U ○☆★□◇◆ 1815 25 3500 2500
1100
ERZV14D112 V14112U ○☆★□◇◆ 680 895 1815 50 5000 4500
(990 to 1210)
ERZV20D112 V20112U ○☆★□◇◆ 1815 100 7500 6500
ERZV10D182CS V10182U ○☆★□◇◆ 2970 25 3500 2500
1800
ERZV14D182CS V14182U ○☆★□◇◆ 1000 1465 2970 50 5000 4500
(1700 to 1980)
ERZV20D182 V20182U ○☆★□◇◆ 2970 100 7500 6500
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 23-Dec-21
53
D type / V5 series
Ratings and characteristics
●Operating temperature range : ‒40 to 85 ℃ ●Storage temperature range : ‒40 to 125 ℃
Clamping
Varistor Maximum Capacitance
Maximum voltage Rated
voltage Maximum energy peak current (max.)
allowable voltage (max.) power
Part No. at 0.1 mA (8/20 μs) at 1 kHz
**lp
AC rms DC (10/1000 μs) (2 ms) 1 time 2 times
(V) (V) (W) (pF)
(V) (V) (J) (J) (A) (A)
ERZV05D180 18(16 to 20) 11 14 40 0.01 0.6 0.4 250 125 1600
ERZV05D220 22(20 to 24) 14 18 48 0.01 0.7 0.5 250 125 1500
ERZV05D270 27(24 to 30) 17 22 60 0.01 0.9 0.7 250 125 1450
ERZV05D330 33(30 to 36) 20 26 73 0.01 1.1 0.8 250 125 1400
ERZV05D390 39(35 to 43) 25 31 86 0.01 1.2 0.9 250 125 700
ERZV05D470 47(42 to 52) 30 38 104 0.01 1.5 1.1 250 125 650
ERZV05D560 56(50 to 62) 35 45 123 0.01 1.8 1.3 250 125 600
ERZV05D680 68(61 to 75) 40 56 150 0.01 2.2 1.6 250 125 580
ERZV05D820 82(74 to 90) 50 65 145 0.1 3.5 2.5 800 600 460
ERZV05D101 100(90 to 110) 60 85 175 0.1 4.0 3.0 800 600 400
ERZV05D121 120(108 to 132) 75 100 210 0.1 5.0 3.5 800 600 350
ERZV05D151 150(135 to 165) 95 125 260 0.1 6.5 4.5 800 600 300
★The following part numbers, kindly also consider corresponding, smaller E Series devices with better performance for their size. → Please click here
ERZV05D201 200(185 to 225) 130 170 355 0.1 8.5 6.0 800 600 120
ERZV05D221 220(198 to 242) 140 180 380 0.1 9.0 6.5 800 600 110
ERZV05D241 240(216 to 264) 150 200 415 0.1 10.5 7.5 800 600 100
ERZV05D271 270(247 to 303) 175 225 475 0.1 11.0 8.0 800 600 90✽
ERZV05D331 330(297 to 363) 210 270 570 0.1 13.0 9.5 800 600 80✽
ERZV05D361 360(324 to 396) 230 300 620 0.1 16.0 11.0 800 600 80✽
ERZV05D391 390(351 to 429) 250 320 675 0.1 17.0 12.0 800 600 80✽
ERZV05D431 430(387 to 473) 275 350 745 0.1 20.0 13.5 800 600 70✽
ERZV05D471 470(423 to 517) 300 385 810 0.1 21.0 15.0 800 600 60✽
✽Measured at 1 MHz ✽✽Ip Measuring current of clamping voltage 180 to 680 : 1 A, 820 to 471 : 5 A
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 23-Dec-21
54
D type / V5 series
Typical characteristics
Voltage vs. Current Impulse Derating (Relation between
impulse width and impulse current multiple)
270 100
390
100 220
90
80 180
70
60
40
30 10
20
10
9 1
8
7
6
5
Test current waveform
10–6 to 10–4 A: Direct current
4 10–1 to 103 A: 8/20 μs
3
10-6 10-5 10-4 10-3 10-2 10-1 100 101 102 103 104 105 0.1
20 100 1000 10000
Current (A)
Impulse width (μs)
471
431 431
391 391
1000 361 361
331
900
271 100
800
241
700 221
600 201
500
Impulse current (A)
151
400
Voltage (V)
121
300 101
10
820
200
100
90 1
80
70
60
50 Test current waveform
331 10–6 to 10–4 A: Direct current
10–1 to 103 A: 8/20 μs
40 221
30
10-6 10-5 10-4 10-3 10-2 10-1 100 101 102 103 104 105 0.1
20 100 1000 10000
Current (A) Impulse width (μs)
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 23-Dec-21
55
D type / V7 series
Ratings and characteristics
●Operating temperature range : ‒40 to 85 ℃ ●Storage temperature range : ‒40 to 125 ℃
Clamping
Varistor Maximum Capacitance
Maximum voltage Rated
voltage Maximum energy peak current (max.)
allowable voltage (max.) power
Part No. at 1 mA (8/20 μs) at 1 kHz
**lp
AC rms DC (10/1000 μs) (2 ms) 1 time 2 times
(V) (V) (W) (pF)
(V) (V) (J) (J) (A) (A)
ERZV07D180 18(16 to 20) 11 14 36 0.02 1.1 0.9 500 250 3800
ERZV07D220 22(20 to 24) 14 18 43 0.02 1.3 1.1 500 250 3600
ERZV07D270 27(24 to 30) 17 22 53 0.02 1.6 1.3 500 250 3400
ERZV07D330 33(30 to 36) 20 26 65 0.02 2.0 1.6 500 250 2900
ERZV07D390 39(35 to 43) 25 31 77 0.02 2.4 1.9 500 250 1600
ERZV07D470 47(42 to 52) 30 38 93 0.02 2.8 2.3 500 250 1550
ERZV07D560 56(50 to 62) 35 45 110 0.02 3.4 2.7 500 250 1500
ERZV07D680 68(61 to 75) 40 56 135 0.02 4.1 3.3 500 250 1200
ERZV07D820 82(74 to 90) 50 65 135 0.25 7 5 1750 1250 810
ERZV07D101 100(90 to 110) 60 85 165 0.25 8.5 6 1750 1250 700
ERZV07D121 120(108 to 132) 75 100 200 0.25 10 7 1750 1250 590
ERZV07D151 150(135 to 165) 95 125 250 0.25 13 9 1750 1250 500
★The following part numbers, kindly also consider corresponding, smaller E Series devices with better performance for their size. → Please click here
ERZV07D201 200(185 to 225) 130 170 340 0.25 17.5 12.5 1750 1250 200
ERZV07D221 220(198 to 242) 140 180 360 0.25 19 13.5 1750 1250 190
ERZV07D241 240(216 to 264) 150 200 395 0.25 21 15 1750 1250 170
ERZV07D271 270(247 to 303) 175 225 455 0.25 24 17 1750 1250 150
ERZV07D331 330(297 to 363) 210 270 545 0.25 28 20 1750 1250 130
ERZV07D361 360(324 to 396) 230 300 595 0.25 32 23 1750 1250 130
ERZV07D391 390(351 to 429) 250 320 650 0.25 35 25 1750 1250 130
ERZV07D431 430(387 to 473) 275 350 710 0.25 40 27.5 1750 1250 120
ERZV07D471 470(423 to 517) 300 385 775 0.25 42 30 1750 1250 100
ERZV07D511 510(459 to 561) 320 410 845 0.25 45 32 1750 1250 90✽
✽Measured at 1 MHz ✽✽Ip Measuring current of clamping voltage 180 to 680 : 2.5 A, 820 to 511 : 10 A
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 23-Dec-21
56
D type / V7 series
Typical characteristics
Voltage vs. Current Impulse Derating (Relation between
impulse width and impulse current multiple)
470
200 390
330
270 100
220
100
90 180
80
50
40
10
30
20
10 1
9
8
7
6
5
Test current waveform
4 10–6 to 10–3 A: Direct current
10–1 to 103 A: 8/20 μs
3 0.1
10-6 10-5 10-4 10-3 10-2 10-1 100 101 102 103 104 105 20 100 1000 10000
Impulse width (μs)
Current (A)
500 151
Voltage (V)
400 121
820
200
100
90 10
80
70
60
50 Test current waveform
10–6 to 10–3 A: Direct current
10–1 to 104 A: 8/20 μs
331
40
321
30 1
10-6 10-5 10-4 10-3 10-2 10-1 100 101 102 103 104 105 20 100 1000 10000
Current (A)
Impulse width (μs)
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 23-Dec-21
57
D type / V9 series
Ratings and characteristics
●Operating temperature range : ‒40 to 85 ℃ ●Storage temperature range : ‒40 to 125 ℃
Clamping
Varistor Maximum Capacitance
Maximum voltage Rated
voltage Maximum energy peak current (max.)
allowable voltage (max.) power
Part No. at 1 mA (8/20 μs) at 1 kHz
**lp
AC rms DC (10/1000 μs) (2 ms) 1 time 2 times
(V) (V) (W) (pF)
(V) (V) (J) (J) (A) (A)
ERZV09D180 18(16 to 20) 11 14 36 0.05 2.6 2.2 1000 500 16000
ERZV09D220 22(20 to 24) 14 18 43 0.05 3.2 2.6 1000 500 11000
ERZV09D270 27(24 to 30) 17 22 53 0.05 3.9 3.2 1000 500 8000
ERZV09D330 33(30 to 36) 20 26 65 0.05 4.8 4.0 1000 500 6300
ERZV09D390 39(35 to 43) 25 31 77 0.05 5.6 4.7 1000 500 5200
ERZV09D470 47(42 to 52) 30 38 93 0.05 6.8 5.6 1000 500 4600
ERZV09D560 56(50 to 62) 35 45 110 0.05 8.1 6.7 1000 500 3750
ERZV09D680 68(61 to 75) 40 56 135 0.05 9.8 8.2 1000 500 2800
ERZV09D820 82(74 to 90) 50 65 135 0.4 14.0 10 3500 2500 2000
ERZV09D101 100(90 to 110) 60 85 165 0.4 17 12 3500 2500 1700
ERZV09D121 120(108 to132) 75 100 200 0.4 20 14.5 3500 2500 1400
ERZV09D151 150(135 to 165) 95 125 250 0.4 25 18 3500 2500 1100
★The following part numbers, kindly also consider corresponding, smaller E Series devices with better performance for their size. → Please click here
ERZV09D201 200(185 to 225) 130 170 340 0.4 35 25 3500 2500 430
ERZV09D221 220(198 to 242) 140 180 360 0.4 39 27.5 3500 2500 410
ERZV09D241 240(216 to264) 150 200 395 0.4 42 30 3500 2500 380
ERZV09D271 270(247 to 303) 175 225 455 0.4 49 35 3500 2500 350
ERZV09D331 330(297 to 363) 210 270 545 0.4 58 42 3500 2500 300
ERZV09D361 360(324 to 396) 230 300 595 0.4 65 45 3500 2500 300
ERZV09D391 390(351 to 429) 250 320 650 0.4 70 50 3500 2500 300
ERZV09D431 430(387 to 473) 275 350 710 0.4 80 55 3500 2500 270
ERZV09D471 470(423 to 517) 300 385 775 0.4 85 60 3500 2500 230
ERZV09D511 510(459 to 561) 320 410 845 0.4 92 67 3500 2500 210
✽Ip Measuring current of clamping voltage 180 to 680 : 5 A, 820 to 511 : 25 A
★The following part numbers, kindly also consider corresponding, smaller E Series devices
L
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 23-Dec-21
58
D type / V9 series
Typical characteristics
Voltage vs. Current Impulse Derating (Relation between
impulse width and impulse current multiple)
270
220 100
180
100
90
80
70
40
10
30
20
10 1
9
8
7
6
5
Test current waveform
4 10–6 to 10–3 A: Direct current
10–1 to 103 A: 8/20 μs
3 0.1
10-6 10-5 10-4 10-3 10-2 10-1 100 101 102 103 104 105 20 100 1000 10000
500 151
400 121
Voltage (V)
101
300 100
820
200
100
90 10
80
70
60
50
Test current waveform
40 331 10–6 to 10–3 A: Direct current
10–1 to 104 A: 8/20 μs
321
30 1
10-6 10-5 10-4 10-3 10-2 10-1 100 101 102 103 104 105 20 100 1000 10000
Current (A) Impulse width (μs)
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 23-Dec-21
59
D type / V10 series
Ratings and characteristics
●Operating temperature range : ‒40 to 85 ℃ ●Storage temperature range : ‒40 to 125 ℃
Clamping
Varistor Maximum Capacitance
Maximum voltage Rated
voltage Maximum energy peak current (max.)
allowable voltage (max.) power
Part No. at 1 mA (8/20 μs) at 1 kHz
**lp
AC rms DC (10/1000 μs) (2 ms) 1 time 2 times
(V) (V) (W) (pF)
(V) (V) (J) (J) (A) (A)
ERZV10D180 18(16 to 20) 11 14 36 0.05 2.6 2.2 1000 500 16000
ERZV10D220 22(20 to 24) 14 18 43 0.05 3.2 2.6 1000 500 11000
ERZV10D270 27(24 to 30) 17 22 53 0.05 3.9 3.2 1000 500 8000
ERZV10D330 33(30 to 36) 20 26 65 0.05 4.8 4.0 1000 500 6300
ERZV10D390 39(35 to 43) 25 31 77 0.05 5.6 4.7 1000 500 5200
ERZV10D470 47(42 to 52) 30 38 93 0.05 6.8 5.6 1000 500 4600
ERZV10D560 56(50 to 62) 35 45 110 0.05 8.1 6.7 1000 500 3750
ERZV10D680 68(61 to 75) 40 56 135 0.05 9.8 8.2 1000 500 2800
ERZV10D820 82(74 to 90) 50 65 135 0.4 14 10 3500 2500 2000
ERZV10D101 100(90 to 110) 60 85 165 0.4 17 12 3500 2500 1700
ERZV10D121 120(108 to 132) 75 100 200 0.4 20 14.5 3500 2500 1400
ERZV10D151 150(135 to 165) 95 125 250 0.4 25 18 3500 2500 1100
★The following part numbers, kindly also consider corresponding, smaller E Series devices with better performance for their size. → Please click here
ERZV10D201 200(185 to 225) 130 170 340 0.4 35 25 3500 2500 430
ERZV10D221 220(198 to 242) 140 180 360 0.4 39 27.5 3500 2500 410
ERZV10D241 240(216 to 264) 150 200 395 0.4 42 30 3500 2500 380
ERZV10D271 270(247 to 303) 175 225 455 0.4 49 35 3500 2500 350
ERZV10D331 330(297 to 363) 210 270 545 0.4 58 42 3500 2500 300
ERZV10D361 360(324 to 396) 230 300 595 0.4 65 45 3500 2500 300
ERZV10D391 390(351 to 429) 250 320 650 0.4 70 50 3500 2500 300
ERZV10D431 430(387 to 473) 275 350 710 0.4 80 55 3500 2500 270
ERZV10D471 470(423 to 517) 300 385 775 0.4 85 60 3500 2500 230
ERZV10D511 510(459 to 561) 320 410 845 0.4 92 67 3500 2500 210
ERZV10D561 560(504 to 616) 350 450 930 0.4 92 67 3500 2500 200
ERZV10D621 620(558 to 682) 385 505 1025 0.4 92 67 3500 2500 190
ERZV10D681 680(612 to 748) 420 560 1120 0.4 92 67 3500 2500 170
ERZV10D751 750(675 to 825) 460 615 1240 0.4 100 70 3500 2500 160
ERZV10D821 820(738 to 902) 510 670 1355 0.4 110 80 3500 2500 140
ERZV10D911 910(819 to 1001) 550 745 1500 0.4 130 90 3500 2500 120
ERZV10D102 1000(900 to 1100) 625 825 1650 0.4 140 100 3500 2500 110
ERZV10D112 1100(990 to 1210) 680 895 1815 0.4 155 110 3500 2500 110
ERZV10D182CS 1800(1700 to 1980) 1000 1465 2970 0.4* 247 183*** 3500 2500 ***70✽
✽Measured at 1 MHz ✽✽Ip Measuring current of clamping voltage 180 to 680 : 5 A, 820 to 182 : 25 A
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 23-Dec-21
60
D type / V10 series
Dimensions in mm (not to scale)
Unit : mm
Part No. D max. T max. W±1.0 H max. L±1.0
ERZV10D180 11.5 4.6 7.5 14.5 1.3
ERZV10D220 11.5 4.7 7.5 14.5 1.4
ERZV10D270 11.5 4.8 7.5 14.5 1.5 D
ERZV10D330 11.5 5.0 7.5 14.5 1.7 T
ERZV10D390 11.5 4.9 7.5 14.5 1.6
ERZV10D470 11.5 5.0 7.5 14.5 1.7
ERZV10D560 11.5 5.1 7.5 14.5 1.8
H
ERZV10D680 11.5 5.3 7.5 14.5 2.0
ERZV10D820 11.5 4.5 7.5 14.5 1.6
L
ERZV10D101 11.5 4.7 7.5 14.5 1.8
ERZV10D121 11.5 4.9 7.5 14.5 2.0
20.0 min.
L
ERZV10D151 11.5 5.2 7.5 14.5 2.3
W
★The following part numbers, kindly also consider corresponding, smaller E Series devices
with better performance for their size. → Please click here ø0.8 W
ERZV10D201 11.5 4.8 7.5 14.5 1.9
ERZV10D221 11.5 4.9 7.5 14.5 2.0
ERZV10D241 11.5 5.0 7.5 14.5 2.1
ERZV10D271 11.5 5.2 7.5 14.5 2.3
ERZV10D331 11.5 5.5 7.5 14.5 2.6
ERZV10D361 11.5 5.7 7.5 14.5 2.8 (ERZV10D182CS)
ERZV10D391 11.5 5.8 7.5 14.5 2.9
ERZV10D431 11.5 6.0 7.5 14.5 3.1 D
T
ERZV10D471 11.5 6.2 7.5 14.5 3.3
ERZV10D511 11.5 6.4 7.5 14.5 3.5
ERZV10D561 12.5 6.7 7.5 15.5 3.8
L
ERZV10D621 12.5 7.1 7.5 15.5 4.2
H
ERZV10D681 12.5 7.4 7.5 15.5 4.5
ERZV10D751 12.5 7.8 7.5 15.5 4.9
4.0±1.5
ERZV10D821 12.5 8.1 7.5 15.5 5.2 L
ERZV10D911 12.5 8.6 7.5 15.5 5.7 ø0.8
ERZV10D102 12.5 9.1 7.5 15.5 6.2
ERZV10D112 12.5 9.7 7.5 15.5 6.8
ERZV10D182CS 13.5 14.4 11.0✽ 16.5 10.0 (±1.5)
✽ W2
Typical characteristics
Voltage vs. Current Impulse Derating (Relation between
impulse width and impulse current multiple)
200 330
270 100
220
Impulse current (A)
100 180
90
80
Voltage (V)
70 10
60
50
40
30
1
20
0.1
10 20 100 1000 10000
9
8 Impulse width (μs)
7
6
Test current waveform
5 10–6 to 10–3 A: Direct current
10–1 to 103 A: 8/20 μs
4
3
10-6 10-5 10-4 10-3 10-2 10-1 100 101 102 103 104 105
Current (A)
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 23-Dec-21
61
D type / V10 series
Typical characteristics
Voltage vs. Current Impulse Derating (Relation between
impulse width and impulse current multiple)
600
500
151
400 10
Voltage (V)
121
101
300
820
200 1
20 100 1000 10000
Impulse width (μs)
Current (A)
100
ERZV10D561 to ERZV10D182CS
5000
3000 102
911 112
821 102
1
911
821 20 100 1000 10000
2000
751
681 Impulse width (μs)
621 ERZV10D182CS
561 10000
Voltage (V)
700
600
100
500
400
10
300 751 Test current waveform
681 10–6 to 10–3 A: Direct current
621 10–1 to 104 A: 8/20 μs
200 1
10-6 10-5 10-4 10-3 10-2 10-1 100 101 102 103 104 105
20 100 1000 10000
Current (A)
Impulse width (μs)
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 23-Dec-21
62
D type / V14 series
Ratings and characteristics
●Operating temperature range : ‒40 to 85 ℃ ●Storage temperature range : ‒40 to 125 ℃
Clamping
Varistor Maximum Capacitance
Maximum voltage Rated
voltage Maximum energy peak current (max.)
allowable voltage (max.) power
Part No. at 1 mA (8/20 μs) at 1 kHz
**lp
AC rms DC (10/1000 μs) (2 ms) 1 time 2 times
(V) (V) (W) (pF)
(V) (V) (J) (J) (A) (A)
ERZV14D180 18(16 to 20) 11 14 36 0.1 5.2 4.3 2000 1000 25000
ERZV14D220 22(20 to 24) 14 18 43 0.1 6.3 5.3 2000 1000 20000
ERZV14D270 27(24 to 30) 17 22 53 0.1 7.8 6.5 2000 1000 16000
ERZV14D330 33(30 to 36) 20 26 65 0.1 9.5 7.9 2000 1000 12200
ERZV14D390 39(35 to 43) 25 31 77 0.1 11 9.4 2000 1000 7000
ERZV14D470 47(42 to 52) 30 38 93 0.1 14 11 2000 1000 6750
ERZV14D560 56(50 to 62) 35 45 110 0.1 16 13 2000 1000 6500
ERZV14D680 68(61 to 75) 40 56 135 0.1 20 16 2000 1000 5500
ERZV14D820 82(74 to 90) 50 65 135 0.6 28 20 6000 5000 3700
ERZV14D101 100(90 to 110) 60 85 165 0.6 35 25 6000 5000 3200
ERZV14D121 120(108 to 132) 75 100 200 0.6 42 30 6000 5000 2700
ERZV14D151 150(135 to 165) 95 125 250 0.6 53 37.5 6000 5000 2200
★The following part numbers, kindly also consider corresponding, smaller E Series devices with better performance for their size. → Please click here
ERZV14D201 200(185 to 225) 130 170 340 0.6 70 50 6000 5000 770
ERZV14D221 220(198 to 242) 140 180 360 0.6 78 55 6000 5000 740
ERZV14D241 240(216 to 264) 150 200 395 0.6 84 60 6000 5000 700
ERZV14D271 270(247 to 303) 175 225 455 0.6 99 70 6000 5000 640
ERZV14D331 330(297 to 363) 210 270 545 0.6 115 80 6000 4500 580
ERZV14D361 360(324 to 396) 230 300 595 0.6 130 90 6000 4500 540
ERZV14D391 390(351 to 429) 250 320 650 0.6 140 100 6000 4500 500
ERZV14D431 430(387 to 473) 275 350 710 0.6 155 110 6000 4500 450
ERZV14D471 470(423 to 517) 300 385 775 0.6 175 125 6000 4500 400
ERZV14D511 510(459 to 561) 320 410 845 0.6 190 136 6000 4500 350
ERZV14D561 560(504 to 616) 350 450 930 0.6 190 136 5000 4500 340
ERZV14D621 620(558 to 682) 385 505 1025 0.6 190 136 5000 4500 330
ERZV14D681 680(612 to 748) 420 560 1120 0.6 190 136 5000 4500 320
ERZV14D751 750(675 to 825) 460 615 1240 0.6 210 150 5000 4500 310
ERZV14D821 820(738 to 902) 510 670 1355 0.6 235 165 5000 4500 280
ERZV14D911 910(819 to 1001) 550 745 1500 0.6 255 180 5000 4500 250
ERZV14D102 1000(900 to 1100) 625 825 1650 0.6 280 200 5000 4500 230
ERZV14D112 1100(990 to 1210) 680 895 1815 0.6 310 220 5000 4500 210
ERZV14D182CS 1800(1700 to 1980) 1000 1465 2970 0.6 510 360 5000 4500 120
✽Ip Measuring current of clamping voltage 180 to 680 : 10 A, 820 to 182 : 50 A
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 23-Dec-21
63
D type / V14 series
Dimensions in mm (not to scale)
Unit : mm
Part No. D max. T max. W±1.0 H max. L±1.0
ERZV14D180 15.5 4.6 7.5 18.5 1.3 D
T
ERZV14D220 15.5 4.7 7.5 18.5 1.4
ERZV14D270 15.5 4.8 7.5 18.5 1.5
ERZV14D330 15.5 5.0 7.5 18.5 1.7
H
ERZV14D390 15.5 4.9 7.5 18.5 1.6
ERZV14D470 15.5 5.0 7.5 18.5 1.7
ERZV14D560 15.5 5.1 7.5 18.5 1.8 L
ERZV14D680 15.5 5.3 7.5 18.5 2.0
20.0 min.
ERZV14D820 15.5 4.5 7.5 18.5 1.6
L
ERZV14D101 15.5 4.7 7.5 18.5 1.8 W
ERZV14D121 15.5 4.9 7.5 18.5 2.0
ERZV14D151 15.5 5.2 7.5 18.5 2.3 ø0.8 W
★The following part numbers, kindly also consider corresponding, smaller E Series devices
with better performance for their size. → Please click here
ERZV14D201 15.5 4.8 7.5 18.5 1.9
ERZV14D221 15.5 4.9 7.5 18.5 2.0
ERZV14D241 15.5 5.0 7.5 18.5 2.1
ERZV14D271 15.5 5.2 7.5 18.5 2.3
ERZV14D331 15.5 5.5 7.5 18.5 2.6 (ERZV14D182CS)
ERZV14D361 15.5 5.7 7.5 18.5 2.8
ERZV14D391 15.5 5.8 7.5 18.5 2.9 D
T
ERZV14D431 15.5 6.0 7.5 18.5 3.1
ERZV14D471 15.5 6.2 7.5 18.5 3.3
ERZV14D511 15.5 6.4 7.5 18.5 3.5
ERZV14D561 16.0 6.7 7.5 19.0 3.8
L
H
ERZV14D621 16.0 7.1 7.5 19.0 4.2
ERZV14D681 16.0 7.4 7.5 19.0 4.5
4.0±1.5
ERZV14D751 16.0 7.8 7.5 19.0 4.9 ø0.8 L
ERZV14D821 16.0 8.1 7.5 19.0 5.2
ERZV14D911 16.0 8.6 7.5 19.0 5.7
ERZV14D102 16.0 9.1 7.5 19.0 6.2
ERZV14D112 16.0 9.7 7.5 19.0 6.8
Typical characteristics
Voltage vs. Current Impulse Derating (Relation between
impulse width and impulse current multiple)
ERZV14D180 to ERZV14D680 ERZV14D180 to ERZV14D680
80
70
Voltage (V)
60 100
50
40
30
10
20
10 1
20 100 1000 10000
9
8
Impulse width (μs)
7
6
5 Test current waveform
10–6 to 10–3 A: Direct current
4 10–1 to 104 A: 8/20 μs
3
10-6 10-5 10-4 10-3 10-2 10-1 100 101 102 103 104 105
Current (A)
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 23-Dec-21
64
D type / V14 series
Typical characteristics
Voltage vs. Current Impulse Derating (Relation between
impulse width and impulse current multiple)
400 101
820 10
300
200
1
20 100 1000 10000
Current (A)
100
ERZV14D561 to ERZV14D182CS
5000
102
3000 911
821 112
102 1
911
821 20 100 1000 10000
2000 Impulse width (μs)
751
681
621 ERZV14D182CS
561
10000
2 times:5 min. interval
Voltage (V)
800
700
600
100
500
400
10
300
Test current waveform
751 10–6 to 10–3 A: Direct current
10–1 to 104 A: 8/20 μs
681
621
200 1
10-6 10-5 10-4 10-3 10-2 10-1 100 101 102 103 104 105 20 100 1000 10000
Current (A) Impulse width (μs)
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 23-Dec-21
65
D type / V20 series
Ratings and characteristics
●Operating temperature range : ‒40 to 85 ℃ ●Storage temperature range : ‒40 to 125 ℃
Clamping
Varistor Maximum Capacitance
Maximum voltage Rated
voltage Maximum energy peak current (max.)
allowable voltage (max.) power
Part No. at 1 mA (8/20 μs) at 1 kHz
**lp
AC rms DC (10/1000 μs) (2 ms) 1 time 2 times
(V) (V) (W) (pF)
(V) (V) (J) (J) (A) (A)
ERZV20D180 18(16 to 20) 11 14 36 0.2 13 12 3000 2000 40000
ERZV20D220 22(20 to 24) 14 18 43 0.2 16 14 3000 2000 30000
ERZV20D270 27(24 to 30) 17 22 53 0.2 19 17 3000 2000 24500
ERZV20D330 33(30 to 36) 20 26 65 0.2 24 21 3000 2000 20000
ERZV20D390 39(35 to 43) 25 31 77 0.2 28 25 3000 2000 13800
ERZV20D470 47(42 to 52) 30 38 93 0.2 34 30 3000 2000 13500
ERZV20D560 56(50 to 62) 35 45 110 0.2 41 36 3000 2000 12200
ERZV20D680 68(61 to 75) 40 56 135 0.2 49 44 3000 2000 11500
ERZV20D820 82(74 to 90) 50 65 135 1.0 56 40 10000 7000 7500
ERZV20D101 100(90 to 110) 60 85 165 1.0 70 50 10000 7000 6500
ERZV20D121 120(108 to 132) 75 100 200 1.0 85 60 10000 7000 5500
ERZV20D151 150(135 to 165) 95 125 250 1.0 106 75 10000 7000 4500
★The following part numbers, kindly also consider corresponding, smaller E Series devices with better performance for their size. → Please click here
ERZV20D201 200(185 to 225) 130 170 340 1.0 140 100 10000 7000 1700
ERZV20D221 220(198 to 242) 140 180 360 1.0 155 110 10000 7000 1600
ERZV20D241 240(216 to 264) 150 200 395 1.0 168 120 10000 7000 1500
ERZV20D271 270(247 to 303) 175 225 455 1.0 190 135 10000 7000 1300
ERZV20D331 330(297 to 363) 210 270 545 1.0 228 160 10000 6500 1100
ERZV20D361 360(324 to 396) 230 300 595 1.0 255 180 10000 6500 1100
ERZV20D391 390(351 to 429) 250 320 650 1.0 275 195 10000 6500 1100
ERZV20D431 430(387 to 473) 275 350 710 1.0 303 215 10000 6500 1000
ERZV20D471 470(423 to 517) 300 385 775 1.0 350 250 10000 6500 900
ERZV20D511 510(459 to 561) 320 410 845 1.0 382 273 10000 6500 800
ERZV20D561 560(504 to 616) 350 450 930 1.0 382 273 7500 6500 750
ERZV20D621 620(558 to 682) 385 505 1025 1.0 382 273 7500 6500 700
ERZV20D681 680(612 to 748) 420 560 1120 1.0 382 273 7500 6500 650
ERZV20D751 750(675 to 825) 460 615 1240 1.0 420 300 7500 6500 600
ERZV20D821 820(738 to 902) 510 670 1355 1.0 460 325 7500 6500 530
ERZV20D911 910(819 to 1001) 550 745 1500 1.0 510 360 7500 6500 500
ERZV20D102 1000(900 to 1100) 625 825 1650 1.0 565 400 7500 6500 450
ERZV20D112 1100(990 to 1210) 680 895 1815 1.0 620 440 7500 6500 400
ERZV20D182 1800(1700 to 1980) 1000 1465 2970 1.0 1020 720 7500 6500 250
✽Ip Measuring current of clamping voltage 180 to 680 : 20 A, 820 to 182 : 100 A
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 23-Dec-21
66
D type / V20 series
Dimensions in mm (not to scale)
Unit : mm
Part No. D max. T max. W±1.0 H max. L±1.0
ERZV20D180 21.5 5.1 10.0 24.5 1.5
ERZV20D220 21.5 5.2 10.0 24.5 1.6
ERZV20D270 21.5 5.3 10.0 24.5 1.7
ERZV20D330 21.5 5.5 10.0 24.5 1.9 D
T
ERZV20D390 21.5 5.5 10.0 24.5 1.9
ERZV20D470 21.5 5.6 10.0 24.5 2.0
ERZV20D560 21.5 5.7 10.0 24.5 2.1
H
ERZV20D680 21.5 5.8 10.0 24.5 2.2
ERZV20D820 21.5 4.9 10.0 24.5 1.8 L
ERZV20D101 21.5 5.1 10.0 24.5 2.0
20.0 min.
ERZV20D121 21.5 5.3 10.0 24.5 2.2
L
ERZV20D151 21.5 5.6 10.0 24.5 2.5 W
★The following part numbers, kindly also consider corresponding, smaller E Series devices ø1.0 W
with better performance for their size. → Please click here
ERZV20D201 21.5 5.2 10.0 24.5 2.1
ERZV20D221 21.5 5.3 10.0 24.5 2.2
ERZV20D241 21.5 5.4 10.0 24.5 2.3
ERZV20D271 21.5 5.6 10.0 24.5 2.5
ERZV20D331 21.5 5.9 10.0 24.5 2.8 (ERZV20D182)
ERZV20D361 21.5 6.1 10.0 24.5 3.0
ERZV20D391 21.5 6.2 10.0 24.5 3.1 D
T
ERZV20D431 21.5 6.4 10.0 24.5 3.3
ERZV20D471 21.5 6.6 10.0 24.5 3.5
H
ERZV20D511 21.5 6.8 10.0 24.5 3.7
L
ERZV20D561 22.5 7.1 10.0 25.5 4.2 L
ERZV20D621 22.5 7.5 10.0 25.5 4.4
20.0 min
ERZV20D681 22.5 7.8 10.0 25.5 4.7
ERZV20D751 22.5 8.2 10.0 25.5 5.1 ø1.0
ERZV20D821 22.5 8.5 10.0 25.5 5.4
ERZV20D911 22.5 9.0 10.0 25.5 5.9
ERZV20D102 22.5 9.5 10.0 25.5 6.4
ERZV20D112 22.5 10.1 10.0 25.5 7.0
ERZV20D182 23.5 14.8 15.0✽ 28.0 10.7 (±2.0)
✽:W 2
Typical characteristics
Voltage vs. Current+B47:AZ78+B47:AX74 Impulse Derating (Relation between
impulse width and impulse current multiple)
ERZV20D180 to ERZV20D680 ERZV20D180 to ERZV20D680
Max.Leakage Max.Clamping Voltage 10000
400 Current 680
2 times:5 min. interval
560 up to 10 times:2 min. interval
300 up to 106 times : 10 sec. interval
470
390
200
330 1000
270
Impulse current (A)
100 220
90
80 180
70
100
60
Voltage (V)
50
40
30
10
20
1
10
20 100 1000 10000
9
8
Impulse width (μs)
7
6
5 Test current waveform
10–6 to 10–3 A: Direct current
4 10–1 to 104 A: 8/20 μs
3
10-6 10-5 10-4 10-3 10-2 10-1 100 101 102 103 104 105
Current (A)
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 23-Dec-21
67
D type / V20 series
Typical characteristics
Voltage vs. Current Impulse Derating (Relation between
impulse width and impulse current multiple)
500 151
121
Voltage (V)
400
101 10
300 820
200
1
20 100 1000 10000
Impulse width (μs)
30
Impulse current (A)
10-6 10-5 10-4 10-3 10-2 10-1 100 101 102 103 104 105
Current (A)
100
ERZV20D561 to ERZV20D182
5000
Max.Leakage Max.Clamping Voltage 182
Current 10
4000
3000 102
112
911
102 1
821 911 20 100 1000 10000
821 Impulse width (μs)
2000 751
681 ERZV20D182
621
10000
561
2 times:5 min. interval
up to 10 times:2 min. interval
Voltage (V)
1000
1000
900
Impulse current (A)
800
700
600 100
500
400
10
300
751 Test current waveform
681 10–6 to 10–3 A: Direct current
621 10–1 to 104 A: 8/20 μs
1
200 20 100 1000 10000
10-6 10-5 10-4 10-3 10-2 10-1 100 101 102 103 104 105
Impulse width (μs)
Current (A)
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 23-Dec-21
68
D type / V series (Leads cut type)
Straight leads cut type (Bulk type)
※ Ratings and characteristics is refer to bulk standard type.
ød
B
W L*
Unit : mm
Series 5 7 9 10 14
Varister voltage
Symbol
180 to 471 180 to 511 180 to 511 180 to 511 561 to 751 821 to 112 180 to 511 561 to 751 821 to 112
D 7.0 max. 8.5 max. 11.5max. 11.5max. 12.5max. 12.5max. 15.5 max. 16.0max. 16.0max.
H 10.0 max. 11.5 max. 14.0max. 14.5max. 15.5max. 15.5max. 18.5 max. 19.0max. 19.0max.
W 5.0±1.0 5.0±1.0 5.0±1.0 7.5±1.0 7.5±1.0 7.5±1.0 7.5±1.0 7.5±1.0 7.5±1.0
+0.06 +0.06 +0.06 +0.08 +0.08 +0.08 +0.08 +0.08 +0.08
ød 0.60
-0.05
0.60
-0.05
0.60
-0.05
0.80
-0.05
0.80
-0.05
0.80
-0.05
0.80
-0.05
0.80
-0.05
0.80
-0.05
B 4.0±1.0 4.0±1.0 4.0±1.0 4.0±1.0 4.0±1.0 4.0±1.5 4.0±1.0 4.0±1.0 4.0±1.5
Standard
ERZV05D□□□CS ERZV07D□□□CS ERZV09D□□□CS ERZV10D□□□CS ERZV10D□□□CS ERZV10D□□□C1 ERZV14D□□□CS ERZV14D□□□CS ERZV14D□□□C1
products part No.
***
C
C
ød
B
W L*
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 23-Dec-21
69
D type / V series (Taping specifications)
Taping specifications for automated assembly (Straight leads and taping)
※ Ratings and characteristics is refer to bulk standard type.
A
P1
W2
H0
F1
H
W0
L
W1
F Position of
H0 dimension
P0 ød øD0 Position of
F1 dimension
t
✽ Dimension “T”: Conforms to each individual specification.
P2 øD △h
TypeⅢ・Ⅳ P T*
A
P1
W2
H0
F1
H
W0
W1
L
F Position of
ød H0 dimension
P0 øD0 Position of
F1 dimension
t
Series 5 7 9 10 14
Varister Voltage
180 to 471 180 to 511 180 to 511 180 to 331 361 to 511 561 to 112 180 to 331 361 to 511 561 to 112
記号
Symbol
Type
TypeⅠ TypeⅠ TypeⅠ TypeⅠ TypeⅡ TypeⅡ type Ⅲ Type Ⅳ Type Ⅳ
P 12.7±1.0 12.7±1.0 12.7±1.0 15.0±1.0 15.0±1.0 15.0±1.0 30.0±1.0 30.0±1.0 30.0±1.0
P0 12.7±0.3 12.7±0.3 12.7±0.3 15.0±0.3 15.0±0.3 15.0±0.3 15.0±0.3 15.0±0.3 15.0±0.3
P1 3.85±0.70 3.85±0.70 3.85±0.70 3.75±0.70 3.75±0.70 3.75±0.70 3.75±0.70 3.75±0.70 3.75±0.70
P2 6.35±1.30 6.35±1.30 6.35±1.30 7.5±1.3 7.5±1.3 7.5±1.3 7.5±1.3 7.5±1.3 7.5±1.3
+0.06 +0.06 +0.06 +0.08 +0.08 +0.08 +0.08 +0.08 +0.08
ød 0.60 0.60 0.60 0.80 0.80 0.80 0.80 0.80 0.80
-0.05 -0.05 -0.05 -0.05 -0.05 -0.05 -0.05 -0.05 -0.05
F 5.0±0.5 5.0±0.5 5.0±0.5 7.5±0.5 7.5±0.5 7.5±0.5 7.5±0.5 7.5±0.5 7.5±0.5
△h 0±2 0±2 0±2 0±2 0±2 0±2 0±2 0±2 0±2
+1.0 +1.0 +1.0 +1.0 +1.0 +1.0 +1.0 +1.0 +1.0
W 18.0
-0.5
18.0
-0.5
18.0
-0.5
18.0
-0.5
18.0
-0.5
18.0
-0.5
18.0
-0.5
18.0
-0.5
18.0
-0.5
W0 5.0 min. 5.0 min. 5.0 min. 5.0 min. 5.0 min. 5.0 min. 5.0 min. 5.0 min. 5.0 min.
W1 9.0±0.5 9.0±0.5 9.0±0.5 9.0±0.5 9.0±0.5 9.0±0.5 9.0±0.5 9.0±0.5 9.0±0.5
W2 3 max. 3 max. 3 max. 3 max. 3 max. 3 max. 3 max. 3 max. 3 max.
H Approx. 20 Approx. 20 Approx. 20 Approx. 22 Approx. 22 Approx. 22 Approx. 22 Approx. 22 Approx. 22
+2.0 +2.0
H0 17.0±0.5 17.0±0.5 17.0±0.5 18.0 ―― ―― 18.0 ―― ――
0 0
+0.75 +0.75 +0.75 +0.75
F1 ―― ―― ―― ―― 16.00 16.00 ―― 16.00 16.00
-0.5 -0.5 -0.5 -0.5
øD0 ø4.0±0.2 ø4.0±0.2 ø4.0±0.2 ø4.0±0.2 ø4.0±0.2 ø4.0±0.2 ø4.0±0.2 ø4.0±0.2 ø4.0±0.2
t 0.6±0.3 0.6±0.3 0.6±0.3 0.6±0.3 0.6±0.3 0.6±0.3 0.6±0.3 0.6±0.3 0.6±0.3
L 11 max. 11 max. 11 max. 11 max. 11 max. 11 max. 11 max. 11 max. 11 max.
øD 7.0 max. 8.5 max. 11.5 max. 11.5 max. 11.5 max. 12.5 max. 15.5 max. 15.5 max. 16.0 max.
A 10.0 max. 11.5 max. 14.0 max. 14.5 max. 14.5 max. 15.5 max. 18.5 max. 18.5 max. 19.0 max.
Standard
Products Part No. ERZVA5D□□□ ERZVA7D□□□ ERZVA9D□□□ ERZVGAD□□□ ERZVGAD□□□ ERZVGAD□□□ ERZVGED□□□ ERZVGED□□□ ERZVGED□□□
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 23-Dec-21
70
D type / V series (Taping specifications)
Taping specifications for automated assembly (Crimped leads and taping)
※ Ratings and characteristics is refer to bulk standard type.
A
P1
W2
H0
H
W0
W1
L
W
F
P0 ød øD0
t
✽ Dimension “T”: Conforms to each individual specification.
P2 øD △h
P T*
TypeⅡ
A
P1 W0 W2
H0
H
W1
L
F
W
ød
P0 øD0
Series 5 7 9 10 14
Varister Voltage
180 to 471 180 to 511 180 to 511 180 to 331 361 to 511 561 to 112 180 to 331 361 to 511 561 to 112
Type
Symbol
TypeⅠ TypeⅠ TypeⅠ TypeⅠ TypeⅠ TypeⅠ TypeⅡ TypeⅡ TypeⅡ
P 12.7±1.0 12.7±1.0 12.7±1.0 15.0±1.0 15.0±1.0 15.0±1.0 30.0±1.0 30.0±1.0 30.0±1.0
P0 12.7±0.3 12.7±0.3 12.7±0.3 15.0±0.3 15.0±0.3 15.0±0.3 15.0±0.3 15.0±0.3 15.0±0.3
P1 3.85±0.70 3.85±0.70 3.85±0.70 3.75±0.70 3.75±0.70 3.75±0.70 3.75±0.70 3.75±0.70 3.75±0.70
P2 6.35±1.30 6.35±1.30 6.35±1.30 7.5±1.3 7.5±1.3 7.5±1.3 7.5±1.3 7.5±1.3 7.5±1.3
+0.06 +0.06 +0.06 +0.08 +0.08 +0.08 +0.08 +0.08 +0.08
ød 0.60
-0.05
0.60
-0.05
0.60
-0.05
0.80
-0.05
0.80
-0.05
0.80
-0.05
0.80
-0.05
0.80
-0.05
0.80
-0.05
F 5.0±0.5 5.0±0.5 5.0±0.5 7.5±0.5 7.5±0.5 7.5±0.5 7.5±0.5 7.5±0.5 7.5±0.5
△h 0±2 0±2 0±2 0±2 0±2 0±2 0±2 0±2 0±2
W 18.0 +1.0
-0.5 18.0 +1.0
-0.5 18.0 +1.0
-0.5 18.0 +1.0
-0.5 18.0 +1.0
-0.5 18.0 +1.0
-0.5 18.0 +1.0
-0.5 18.0 +1.0
-0.5 18.0 +1.0
-0.5
W0 5.0 min. 5.0 min. 5.0 min. 5.0 min. 5.0 min. 5.0 min. 5.0 min. 5.0 min. 5.0 min.
W1 9.0±0.5 9.0±0.5 9.0±0.5 9.0±0.5 9.0±0.5 9.0±0.5 9.0±0.5 9.0±0.5 9.0±0.5
W2 3 max. 3 max. 3 max. 3 max. 3 max. 3 max. 3 max. 3 max. 3 max.
H Approx. 22 Approx. 22 Approx. 22 Approx. 22 Approx. 22 Approx. 22 Approx. 22 Approx. 22 Approx. 22
H0 17.0±0.5 17.0±0.5 17.0±0.5 16.0±0.5 16.0±0.5 16.0±0.5 16.0±0.5 16.0±0.5 16.0±0.5
øD0 ø4.0±0.2 ø4.0±0.2 ø4.0±0.2 ø4.0±0.2 ø4.0±0.2 ø4.0±0.2 ø4.0±0.2 ø4.0±0.2 ø4.0±0.2
t 0.6±0.3 0.6±0.3 0.6±0.3 0.6±0.3 0.6±0.3 0.6±0.3 0.6±0.3 0.6±0.3 0.6±0.3
L 11 max. 11 max. 11 max. 11 max. 11 max. 11 max. 11 max. 11 max. 11 max.
øD 7.0 max. 8.5 max. 11.5 max. 11.5 max. 11.5 max. 12.5 max. 15.5 max. 15.5 max. 16.0 max.
A 13.0 max. 14.5 max. 17.5 max. 17.5 max. 17.5 max. *(refer) 21.0 max. 21.0 max. *(refer)
Standard
Products Part No. ERZVA5V□□□ ERZVA7V□□□ ERZVA9V□□□ ERZVEAV□□□ ERZVEAV□□□ ERZVEAV□□□ ERZVEEV□□□ ERZVEEV□□□ ERZVEEV□□□
✽Dimension "A"
Part No. 10 Series 14 Series Part No. 10 Series 14 Series
ERZV□□V561 19.0 max. 22.0 max. ERZV□□V821 20.0 max. 23.5 max.
ERZV□□V621 19.0 max. 22.0 max. ERZV□□V911 20.0 max. 23.5 max.
ERZV□□V681 19.0 max. 22.0 max. ERZV□□V102 20.0 max. 23.5 max.
ERZV□□V751 19.0 max. 22.0 max. ERZV□□V112 20.0 max. 23.5 max.
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 23-Dec-21
71
D type / V series
Application note for safety standards
● Approvals products lists in "Reference Guide to Standard Products."
● UL and VDE : Registered in "Type name", it isn’t registered in "Panasonic Part No."
● CQC : Registered in "Panasonic Part No."
● "Rated Voltages" are specified for UL recognized components in list shown below.
V✽820U 50 65 45 N/A
V✽101U 60 85 55 N/A
V✽121U 75 100 68 N/A
V✽151U 95 125 86 N/A
V✽201U 130 170 118 118
V✽221U 140 180 127 127
V✽241U 150 200 136 136
V✽271U 175 225 159 159
V✽331U 210 270 189 189
V✽361U 230 300 209 209
V✽391U 250 320 227 227
V✽431U 275 350 250 250
V✽471U 300 385 272 272
V✽511U 320 410 291 291
V✽561U 350 450 320 320
V✽621U 385 505 350 350
V✽681U 420 560 381 381
V✽751U 460 615 418 418
V✽821U 510 670 463 463
V✽911U 550 745 500 500
V✽102U 625 825 568 568
V✽112U 680 895 600 618
V✽182U 1000 1465 600 909
✽:5 Series is blank, 7 series is 7, 9 series is 9, 10 series is 10, 14 series is 14, 20 series is 20
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 23-Dec-21
72
D type / V series
Explanation of the contents
Mark Explanation of the content
V✽□□□ Abbreviation of
□□□
Part No.
V✽□□□U (Type name) Nominal varistor volage
Marking contents
Series (Example) 5 7 9 10 14 20
Varister voltage (ERZV05D□□□) (ERZV07D□□□) (ERZV09D□□□) (ERZV10D□□□) (ERZV14D□□□) (ERZV20D□□□)
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
73
D type / V series
Performance characteristics
Characteristics Test methods / description Specifications
Electrical measurements (initial/after tests) shall be conducted at temperature of 5 to
Standard test condition ―
35 ℃, relative humidity of maximum 85 %.
The voltage between two terminals with the specified measuring current CmA DC
Varistor voltage applied is called VC or VCmA. The mea sure ment shall be made as fast as possible to
avoid heat affection.
Maximum The maximum sinusoidal RMS voltage or maximum DC voltage that can be applied
allowable voltage continuously.
The maximum voltage between two terminals with the specified
standard impulse current (8/20 μs) illustrated below applied.
100
90
Rated power The power that can be applied in the specified ambient temperature.
The maximum energy within the varistor voltage change of ±10 % when a single
Maximum energy
impulse current of 2 ms or 10/1000 μs is applied.
Maximum The maximum current within the varistor voltage change of ±10 % when a standard
peak current 2times impulse current of 8/20 μs is applied two times with an interval of 5 minutes.
(Withstanding
Surge
The maximum current within the varistor voltage change of ±10 % with a single
Current) 1time
standard impulse current of 8/20 μs is applied.
Withstanding voltage
Classification (Nominal varistor voltage) Test Voltage (AC) No breakdown
(Body Insulation)
V0.1 mA,V1 mA ≦ 330 V 1000 Vrms
V0.1 mA,V1 mA > 330 V 1500 Vrms
The change of VC shall be measured after the impulse current listed below is applied
10000 or 100000 times continuously with the interval of 10 seconds at room
temperature.
Item Impulse Life(Ⅰ) Impulse Life(Ⅱ)
Times ×104 Times ×105 Times
Part No. Current Impulse Current
ERZV05D180 to ERZV05D680 8 A (8/20 μs) 5 A (8/20 μs)
ERZV07D180 to ERZV07D680 25 A (8/20 μs) 15 A (8/20 μs)
ERZV09D180 to ERZV09D680 50 A (8/20 μs) 35 A (8/20 μs)
ERZV10D180 to ERZV10D680 50 A (8/20 μs) 35 A (8/20 μs)
Impulse life ERZV14D180 to ERZV14D680 90 A (8/20 μs) 50 A (8/20 μs) ΔVCmA/VCmA ≦ ±10 %
ERZV20D180 to ERZV20D680 130 A (8/20 μs) 65 A (8/20 μs)
ERZV05D820 to ERZV05D471 40 A (8/20 μs) 25 A (8/20 μs)
ERZV07D820 to ERZV07D511 100 A (8/20 μs) 60 A (8/20 μs)
ERZV09D820 to ERZV09D511 150 A (8/20 μs) 85 A (8/20 μs)
ERZV10D820 to ERZV10D112 150 A (8/20 μs) 85 A (8/20 μs)
ERZV10D182CS 120 A (8/20 μs) 75 A (8/20 μs)
ERZV14D820 to ERZV14D112 200 A (8/20 μs) 110 A (8/20 μs)
ERZV14D182CS 150 A (8/20 μs) 90 A (8/20 μs)
ERZV20D820 to ERZV20D112 250 A (8/20 μs) 120 A (8/20 μs)
ERZV20D182 200 A (8/20 μs) 100 A (8/20 μs)
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
74
D type / V series
Performance characteristics
Characteristics Test methods / description Specifications
After gradually applying the force specified below and keeping the unit fixed for 10
seconds, the terminal shall be visually examined for any damage.
Robustness of
terminations Terminal diameter Force
(Tensile) ø0.6 mm, ø0.8 mm 9.8 N
ø1.0 mm 19.6 N
The unit shall be secured with its terminal kept vertical and the force
specified below shall be applied in the axial direction.
The terminal shall gradually be bent by 90 ° in one direction, then 90 °
in the opposite direction, and again back to the original position. No remarkable mechanical
Robustness of The damage of the terminal shall be visually examined. damage
terminations
(Bending) Terminal diameter Force
ø0.6 mm, ø0.8 mm 4.9 N
Mechanical
ø1.0 mm 9.8 N
After repeadly applying a single harmonic vibration (amplitude: 0.75 mm, double
amplitude: 1.5 mm) with 1 minute vibration frequency cycles (10 Hz to 55 Hz to 10 Hz)
Vibration
to each of three perpendicular directions for 2 hours. Thereafter, the unit shall be
visually examined.
Approximately 95 %
After dipping the terminals to a depth of approximately 3 mm from the body in a of the termainals shall
Solderability
soldering bath of 235±5 °C for 2±0.5 seconds, the terminal shall be visually examined. be covered with new
solder uniformly.
After each lead shall be dipped into a solder bath having a temperature
of 260±5 °C to a point 2.0 to 2.5 mm from the body of the unit, using
Resistance to
shielding board (t=1.5 mm), be held there for 10±1 s and then be stored ΔVCmA/VCmA≦ ±5 %
soldering heat
at room temperature and normal humidity for 1 to 2 hours. The change of
VCmA and mechanical damages shall be examined.
The specimen shall be subjected to 125±2 °C for 1000 hours in a thermostatic bath
High temperature
without load and then stored at room temperature and normal humidity for 1 to 2 hours.
storage/Dry heat
Thereafter, the change of VCmA shall be measured.
ΔVCmA/VCmA≦ ±5 %
The specimen shall be subjected to 40±2 °C, 90 to 95 % RH for 1000 hours without
Humidity load and then stored at room temperature and normal humidity for 1 to 2 hours.
Thereafter, the change of VCmA shall be measured.
The temperature cycle shown below shall be repeated five cycles and then stored at
room temperature and normal humidity for 1 to 2 hours. The change of VCmA and
mechanical damage shall be examined.
1 –40±3 30±3
mechanical damage
2 Room temperature 15±3
3 125±2 30±3
4 Room temperature 15±3
After being continuously applied the Maximum Allowable Voltage at 85±2 °C for 1000
High temperature
hours, the specimen shall be stored at room temperature and normal humidity for 1 to
load/Dry heat load
2 hours. Thereafter, the change of VCmA shall be measured.
ΔVCmA/VCmA ≦ ±10 %
The specimen shall be subjected to 40±2 °C, 90 to 95 % RH and the
Damp heat load/ Maximum Allowable Voltage for 1000 hours and then stored at room
Humidity load temperature and normal humidity for 1 to 2 hours. Thereafter, the change of VCmA shall
be measured.
The specimen shall be subjected to –40±2 °C without load for 1000 hours and then
Low temperature
stored at room temperature and normal humidity for 1 to 2 hours. Thereafter, the ΔVCmA/VCmA ≦ ±5 %
storage/Cold
change of VCmA shall be measured.
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
75
D type / V series
Minimum quantity / Packing unit
Minimum
Packing quantity Carton (about)
Product Series / Type Part number quantity
in carton L×W×H (mm)
/ Packing unit
ERZV05D180 to 271 100 10000 210×340×160
ERZV05D331 to 471 100 10000 210×340×180
ERZV07D180 to 470 100 10000 210×340×160
ERZV07D560 to 680 100 10000 210×340×180
ERZV07D820 to 121 100 10000 210×340×160
ERZV07D151 to 271 100 10000 210×340×180
ERZV07D331 to 511 100 5000 210×340×110
ERZV09D180 to 121 100 5000 210×340×160
ERZV09D151 to 271 100 4000 210×340×130
ERZV09D331 to 511 100 4000 210×340×160
ERZV10D180 to 121 50 5000 210×340×160
ERZV10D151 to 271 50 4000 210×340×130
ERZV10D331 to 621 50 4000 210×340×160
Straight leads
ERZV10D681 to 821 50 2000 210×340×*80
<Bulk>
ERZV10D911 to 112 50 2000 210×340×110
ERZV10D182CS 50 1000 210×340×*80
ERZV14D180 to 121 50 3000 210×340×110
ERZV14D151 to 271 50 3000 210×340×130
ERZV14D331 to 621 50 2000 210×340×110
D type ERZV14D681 to 821 50 2000 210×340×110
V series ERZV14D911 to 112 50 1000 210×340×*80
ERZV14D182CS 50 1000 210×340×*80
ERZV20D180 to 271 50 2000 210×340×160
ERZV20D331 to 511 50 1000 210×340×*80
ERZV20D561 to 821 50 1000 210×340×110
ERZV20D911 to 112 50 1000 210×340×110
ERZV20D182 25 500 210×340×*80
ERZV05D(V)180CS to 271CS 100 10000 210×340×*80
“ZNR” ERZV05D(V)331CS to 471CS 100 10000 210×340×110
Transient/ ERZV07D(V)180CS to 271CS 100 10000 210×340×*80
surge ERZV07D(V)331CS to 511CS 100 10000 210×340×110
absorbers ERZV09D(V)180CS to 121CS 100 5000 210×340×110
ERZV09D(V)151CS to 511CS 100 4000 210×340×*80
Leads cut type
ERZV10D(V)180CS to 121CS 100 5000 210×340×110
<Bulk>
ERZV10D(V)151CS to 621CS 100 4000 210×340×*80
ERZV10D(V)681CS to 751CS 100 2000 210×340×*80
ERZV10D(V)821C1 to 112C1 100 2000 210×340×*80
ERZV14D(V)180CS to 271CS 100 3000 210×340×*80
ERZV14D(V)331CS to 821C1 100 2000 210×340×*80
ERZV14D(V)911C1 to 112C1 100 1000 210×340×*80
ERZVA5D180 to 271 1000 10000 360×320×260
ERZVA5D331 to 471 1000 10000 400×360×260
ERZVA7D180 to 271 1000 10000 400×360×260
ERZVA7D331 to 511 1000 10000 470×360×260
Straight leads ERZVA9D180 to 271 1000 10000 400×360×260
and taped ERZVA9D331 to 511 1000 10000 470×360×260
ERZVGAD180 to 621 1000 5000 360×310×320
ERZVGAD681 to 112 500 2500 360×270×320
ERZVGED180 to 511 500 2500 360×310×320
D type ERZVGED561 to 112 250 1250 360×270×320
V series ERZVA5V180 to 271 1000 10000 360×320×260
ERZVA5V331 to 471 1000 10000 400×360×260
ERZVA7V180 to 271 1000 10000 400×360×260
ERZVA7V331 to 511 1000 10000 470×360×260
Crimped lead ERZVA9V180 to 271 1000 10000 400×360×300
and taped ERZVA9V331 to 511 1000 10000 470×360×300
ERZVEAV180 to 621 1000 5000 360×310×320
ERZVEAV681 to 112 500 2500 360×270×320
ERZVEEV180 to 511 500 2500 360×310×320
ERZVEEV561 to 112 250 1250 360×270×320
Part No., quantity and country of origin are designated on outer packages in English.
※ Please contact local sales office about packing specifications.
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
76
Varistors (ZNR Surge Absorber)
SMD type
HF series
Features
● Meet for load dump surge test (JASO D 001-94) [Vp=70 V,τ=200 ms,Ri=0.8 Ω]
● Meet for load dump surge test ISO7637-2 and ISO16750-2
● Suitable for requirements of automotive
● Compact size SMD
● Meet flow/reflow/iron soldering
● Strong against “Soldering heat shock” due to molded construction
● AEC-Q200 compliant
● RoHS compliant
Recommended applications
● Protection of body & accessory ECU about DC12 V automotive against load dump surge
■ As for handling precautions and minimum quantity / Packing unit please see related information.
E R Z H F 2 M 2 2 0 F
Product code Series Construction Nominal Design No.
Varistor voltage
Embossed taping
Construction
① ②
① Multilayer varistor ZnO, others
② Mold resin Epoxy (UL94 V-0 approved)
ERZHF2M220F : Sn plated Cu alloy
③ Lead terminal
ERZHF2M220D / ERZHF2M270 : Sn plated Ni-Fe alloy
Unit : mm
Dimensions
Part No.
W L H S E
H
ERZHF2M220F
S S 5.5±0.5
E ERZHF2M220D 6.4±0.4 8.0±0.5 1.3±0.3 2.5±0.2
ERZHF2M270 4.5±0.5
L W
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 20-Jan-23
77
SMD type / HF series
Ratings and characteristics
● Operating temperature range : ERZHF2M220F -55 to 150 ℃, ERZHF2M220D/ERZHF2M270 -40 to 125 ℃
● Storage temperature range : ERZHF2M220F -55 to 150 ℃, ERZHF2M220D/ERZHF2M270 -40 to 125 ℃
Marking contents
Minimum quantity
● Packing quantity
Minimum quantity Packing quantity Carton (about)
Product Series / Type Part number / Packing unit in carton L×W×H (mm)
“ZNR” ERZHF2M220F
SMD Embossed 800 3200
Transient/surge ERZHF2M220D 340×345×105
absorbers
type (HF)
ERZHF2M270 1000 4000
※ Part No., quantity and country of origin are designated on outer packages in English. ※ Please contact local sales office about packing specifications.
● Embossed taping
t1
Feeding hole Chip pocket
Width of tape :16 mm
øD0 P2 P0
E
F
B
A P1
t2 Chip component Direction of feed
Unit : mm
● Reel
T
E
C
B
r øD Unit : mm
Part No. A B C øD E
382 max. 50 min. 13.0±0.5 21.0±0.8 2.0±0.5
t ERZHF2M W T t r
A W 16.4+2.0/0 22.4 max. 2.5±0.5 1.0
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 20-Jan-23
78
SMD type / HF series
Performance characteristics
Characteristics Test methods Specifications
Environmental conditions under which every measuring is done without doubt on the
Standard test condition measuring results. Unless specially, specified, temperature, relative humidity are 5 ° -
C to 35 °C, 45 to 85% RH respectively.
Maximum allowable The maximum DC voltage that can be applied continuously in the specified
voltage environmental temperature range.
Short time over-voltage The maximum DC Voltage that can be applied specified period without breakdown.
To meet the
Voltage between both terminals of ZNR measured when 1 mA of DC current is specified value
Varistor voltage applied under standard conditions. It is called V1. Measuring the varistor voltage
should be made promptly to avoid heat affection.
The maximum voltage between two terminals with the specified impulse current (8/20
Clamping voltage
μs).
The test waveform of transient voltage which specified JASO Category
A A-1 70 V without breakdown.
PS Voltage
0V
τ=200 ms
UA
0.1(US-UA) PS Voltage
0V
※ Please Check Specification of the products about Mechanical & Environmental etc. requirements.
Land
8.0
Product
3.0
Occupied Space
6.4
5.0
10.0
Unit : mm
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 20-Jan-23
79
Varistors (ZNR Surge Absorber)
SMD type
VF series
Features
●Large withstanding surge current capability in compact sizes
●Designed for flow/reflow solderings
●Low clamping voltage
●RoHS compliant
Recommended applications
●Protection of communication modules (Modem, xDSL, Terminal Adopter)
●Protection of consumer, industrial equipment
●Absorption of switching surge from relays
■ As for handling precautions and minimum quantity / Packing unit please see related information.
Applicable Standards
●CQC(GB/T10193,GB/T10194)
Registered in "Panasonic Part No."
E R Z V F M
Product Code Series Construction Norminal Design No.
Varistor Voltage
Packaging style
1 Bulk
2 Taping
Construction
② ④
① ZNR element ZnO etc.
② Resin mold Epoxy Resin(UL94V-0 approved)
③
③ Conductive adhesive Silver
① ④ Electrode Silver
⑤ Lead terminals Sn plated Ni-Fe Alloy
S S E
L W
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
80
SMD type / VF series
Ratings and characteristics
●Operating temperature range : -40 to 85 ℃ ●Storage temperature range : ‒40 to 125℃
Measuring current
(V) ACrms (V) DC (V) (V) (W) (J) (A)
(A)
ERZVF□M220 22(20 to 24) 14 18 43 2.5 0.02 0.9 125
ERZVF□M270 27(24 to 30) 17 22 53 2.5 0.02 1.0 125
ERZVF□M330 33(30 to 36) 20 26 65 2.5 0.02 1.2 125
ERZVF□M390 39(35 to 43) 25 31 77 2.5 0.02 1.5 125
ERZVF□M470 47(42 to 52) 30 38 93 2.5 0.02 1.8 125
ERZVF□M560 56(50 to 62) 35 45 110 2.5 0.02 2.2 125
ERZVF□M680 68(61 to 75) 40 56 135 2.5 0.02 2.5 125
ERZVF□M820 82(74 to 90) 50 65 135 10 0.25 3.5 600
ERZVF□M101 100(90 to 110) 60 85 165 10 0.25 4.0 600
ERZVF□M121 120(108 to 132) 75 100 200 10 0.25 5.0 600
ERZVF□M151 150(135 to 165) 95 125 250 10 0.25 6.0 600
ERZVF□M201 200(185 to 225) 130 170 340 10 0.25 8.0 600
ERZVF□M221 220(198 to 242) 140 180 360 10 0.25 9.0 600
ERZVF□M241 240(216 to 264) 150 200 395 10 0.25 10.0 600
ERZVF□M271 270(247 to 303) 175 225 455 10 0.25 12.0 600
ERZVF□M331 330(297 to 363) 210 270 545 10 0.1 8.0 300
ERZVF□M361 360(324 to 396) 230 300 595 10 0.1 9.0 300
ERZVF□M391 390(351 to 429) 250 320 650 10 0.1 9.0 300
ERZVF□M431 430(387 to 473) 275 350 710 10 0.1 10.0 300
ERZVF□M471 470(423 to 517) 300 385 775 10 0.1 10.0 300
↑
Packaging Style Code: “1” for bulk, “2” for embossed taping
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
81
SMD type / VF series
Typical characteristics
Voltage vs. Current Impulse Derating (Relation between
impulse width and impulse current multiple)
70
60 1
50
0.5
40 0.4
0.3
30 0.2
0.1
20
50
40
30
20
10
5
4
3
2
ERZVF1(2)M820 to ERZVF1(2)M471 1
101
200 820
10
100
90
80
1
70
60
50 Test current waveform
10–6 to 10–3 A: Direct current
10–1 to 104 A: 8/20 μs
40 241
221 0.1
30
20 100 1000 10000
10-6 10-5 10-4 10-3 10-2 10-1 100 101 102 103 104
Impulse width (μs)
Current (A)
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
82
SMD type / VF series
Marking contents
Minimum quantity
●Packing Quantity
※ Part No., quantity and country of origin are designated on outer packages in English.
※ Please contact local sales office about packing specifications.
E W=16mm
C t1 Feeding hole
Chip pocket
øD0 P2 P0
B
r D E
A F
W
B
Unit : mm Unit : mm
Part No. t1 t2
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
83
SMD type / VF series
Performance characteristics
Characteristics Test methods Specifications
Electrical measurements (initial/after tests) shall be conducted at temperature of 5 to
Standard test condition
35 ℃, relative humidity of maximum 85 %. ―
The voltage betwen two terminals with the specified measuring current 1 mA
Varistor voltage DC applied is called V1 or V1 mA. The measurement shall be made as fast as
possible to avoid heat affection.
Maximum The maximum sinusoidal RMS voltage or maximum DC voltage that can be
allowable voltage applied continuously.
The maximum voltage between two terminals with the specified
Clamping voltage
standard impulse current (8/20 μs) illustrated below applied. To meet the
Rated power The power that can be applied in the specified ambient temperature. specified value.
Land
8.0
Product
3.0
6.0
Occupied
5.0 Space
10.0 Unit : mm
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
84
Matters to Be Observed When Using This Product
Safety measures
An abnormal state of E-Type, CK-type, and SC-type varistors (ZNR surge absorber, hereinafter "the product" or "the surge
absorber") that results from a problem with service conditions (materials used, the surrounding environment, power
conditions, circuit conditions, etc.) may cause a fire accident, electric shock accident, burn accident, or product failure.
Matters to note when handling this product will hereinafter be described. What is described below should be checked
sufficiently before the product is used.
■ Take the following measures in order to avoid an accident caused by expected phenomenon.
(1) Destruction of the surge absorber may scatter its fractured pieces around. To protect other elements from these
pieces, set product in a case or shield it with a cover.
(2) Do not place the surge absorber near combustible materials (vinyl cable, resin mold, etc.). If avoiding the vicinity
of combustible materials is difficult, protect the combustible material with an incombustible cover.
(3) Surge absorber placed between lines
When the surge absorber is placed between lines, connect a normal type current fuse in series with the surge
absorber.
* See "Current fuse" in the "Circuit design and circuit board design" section.
(4) Surge absorber placed between a line and the ground
① When the surge absorber is placed between a line and the ground, even if the surge absorber short-circuits,
ground resistance will remain in the section between the line and the ground, leaving a possibility that the
current fuse won’t blow, in which case the outer sheath resin of the surge absorber may generate smoke or
ignite due to current flow. To prevent such a case, place an earth leakage breaker in a location closer to the
power supply than the surge absorber. When not using an earth leakage breaker, use a current fuse and
temperature fuse in series with each other.
* See Table 1 in the "Circuit design and circuit board design" section.
② When the surge absorber is placed between a live part and a metal case, it may cause electric shock if the
surge absorber short-circuits. To avoid this, ground the metal case or shield it to prevent direct contact with the
metal case.
■ In case the surge absorber should short-circuit and generate smoke or ignite, immediately cut off current flow
to the surge absorber.
■ An unexpected sharp rise in the working voltage, an incoming excessive surge, etc., may cause the surge absorber to
generate smoke or ignite.
In such a case, fire spreading through the device should be prevented to avoid expanded damage. To achieve this,
take a multi-protection measure, such as adopting fire-resistant materials that make up the outer shell components
and structural materials.
■ Do not use the surge absorber in which direct sunlight hits the surge absorber or near a heating element where the
temperature of the surge absorber would rise above its working temperature.
■ Do not use the surge absorber in a place where the surge absorber is exposed to wind or rain or a highly humid place
where steam is emitted or dew concentrates.
■ Do not use the surge absorber in a place filled with dust or salt, in an atmosphere contaminated with a corrosive gas,
etc., or in liquids such as water, oil, chemical, or organic solvents.
30-Jun-23
85
Matters to Be Observed When Using This Product
■ Do not wash the surge absorber with a solvent (thinner, acetone, etc.) that damages the outer sheath resin.
■ Choose a surge absorber whose maximum allowable circuit voltage has a margin relative to the maximum voltage range
including source voltage fluctuations.
* See Table 1 in the "Circuit design and circuit board design" section.
■ When surges are applied intermittently to the surge absorber at short intervals (when pulses of voltages are applied in a
noise simulator test, etc.), make sure that the surge power does not exceed the maximum average pulse power of the surge
absorber.
■ The product numbers of recommended surge absorbers to choose are shown in Table 1.
■ Current fuse
(1) Select a surge absorber and fuses to use in as shown in the following table.
Confirm that no secondary accident arises when the surge absorber in an actual circuit breaks. Selected rated currents of
current fuses shown in the following table are exemplary one and may vary depending on circuit conditions used. Confirm
the rated current by a test, etc., before using the current fuse.
* Use the rated voltage of the current fuse that corresponds to the circuit voltage of a circuit including the current fuse.
* Connect a temperature fuse directly to the terminal so that heat from the terminal is easily transferred to the fuse and that the
fusing element of the fuse extends along its sides.
(2) Recommended parts where fuses are connected are shown in Table 1. When a load current to a protected device is so
large as to exceed the rated current of the fuse, however, connect the fuse in a location shown in the following diagram.
Current fuse
Power supply Protected
device
ZNR
30-Jun-23
86
Matters to Be Observed When Using This Product
DC DC
Single-phase AC Single-phase AC
Current fuse ZNR1
Current fuse ZNR1
L
L Protected
Protected device
device N
N ZNR2
Thermal Temperature
coupling fuse
Connection
Three-phase AC Three-phase AC
Current fuse
Current fuse
ZNR3 ZNR3 ZNR3
Protected
device
Protected ZNR3
device
ZNR4
ZNR3 Temperature
Thermal
fuse
coupling
* To find out about surge absorbers that can be used in an AC withstand voltage test,
please contact us.
Processing conditions
■ Do not apply vibration, impact (drop impact, etc.), or pressure strong enough to crack the outer sheath resin or absorber
body of the surge absorber.
■ When coating the surge absorber with a resin or embedding it in a resin mold, avoid using a resin that degrades the
surge absorber.
■ Do not bend the surge absorber or apply force thereto close to the insulation cover of the lead terminal.
■ Do not keep the product in a high-temperature or high-humidity condition. Keep the surge absorber in a room with
a temperature of 40 ℃ or lower and a relative humidity of 75% or lower and use the surge absorber within two years of
storage.
■ Keep the surge absorber in a place where no corrosive gas atmosphere (hydrogen sulfide, sulfurous acid, chlorine,
ammonia, etc.) is present.
■ Keep the surge absorber in a place where the surge absorber is protected from direct sunlight, dew concentration, etc.
30-Jun-23
87
Varistors (ZNR Surge Absorber)
SC type
Features
●Very large surge withstanding capability with a compact size
●Fast response to steep impulse voltage
●Low clamping voltage for better surge protection
●No follow-on current
●RoHS compliant
Recommended applications
●Power suppliers for OA, FA, telecommunication or industrial equipment
●Traffic or railroad systems
●Surge protection of automatic control devices for power distribution line
■ As for handling precautions and minimum quantity / Packing unit please see related information.
1 2 3 4 5 6 7 8 9 10 11 12
E R Z V S 3 4 C
Product code Series Shape Element size Type Nominal Design No.
varistor voltage
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
88
SC type
Typical characteristics
Voltage vs. Current (ERZVS34C201 to ERZVS34C951)
10000
Max.Leakage
Current Max.Clamping Voltage
ERZVS34C951
ERZVS34C951 ERZVS34C821
ERZVS34C751
ERZVS34C821 ERZVS34C621
ERZVS34C751 ERZVS34C511
ERZVS34C621 ERZVS34C471
ERZVS34C431
ERZVS34C511 ERZVS34C361
1000 ERZVS34C471 ERZVS34C271
ERZVS34C241
ERZVS34C201
Voltage (V)
100
ERZVS34C431
ERZVS34C361
ERZVS34C271
ERZVS34C241
ERZVS34C201
10
1.E-06 1.E-05 1.E-04 1.E-03 1.E-02 1.E-01 1.E+00 1.E+01 1.E+02 1.E+03 1.E+04 1.E+05
Current (A)
ERZVS34C201 9.0
Part number ZNR ERZVS34C241 9.2
ERZVS34C271 9.5
ERZVS34C361 10.4
H
Date code
ERZVS34C431 11.1
ERZVS34C471 36 47 11.3
ERZVS34C511 9.7
18 ERZVS34C621 9.7
25 ERZVS34C751 10.5
7 7 ERZVS34C821 11.0
ERZVS34C951 11.5
8
2 ø3.4
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
89
Varistors (ZNR Surge Absorber)
E type
Features
●UL and CSA recognized components
●Very large surge withstanding capability with a compact size
●Direct mounting on boards like a power distribution board available
●Fast response to steep impulse voltage
●Low clamping voltage for better surge protection
●RoHS compliant
Recommended applications
●Transistor, diode, IC, thyristor or triac semiconductor protection
●Surge protection in industrial power plant operations
●Relay or electromagnetic valve surge absorption
●Surge absorption applications in broadcasting, communications devices, traffic/railroad,
agricultural facilities, waterworks
●Surge protection of automatic control devices for power distribution line
Related standards
Standard No. UL1449 CSA C22.2 No.269.5
Title Surge protective devices Surge protective devices - Type 5 – Components
●Each type designation is not registered by Part Number.
E R Z C E K
Product code Element size Type Tolerance Nominal varistor voltage Design No.
― General
Y UL/CSA Recognized
Unit : mm
L Part No. W H L
W
ERZC20EK□□□(Y) 48±1 42±1 39±1
12 ERZC32EK□□□(Y) 60±1 55±1 51±1
5
ZNR
Part No.
H
Date code
14
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
90
E type / 20, 32 series (UL and CSA Recognized)
Ratings and characteristics (20 series)
●Operating temperature range : ‒40 to 85 ℃ ●Storage temperature range : ‒40 to 110 ℃
Maximum
Maximum Maximum peak
Varistor Maximum energy Rated
clamping current
Part No. voltage allowable (2ms) voltage
Type voltage
(UL/CSA at 1 mA voltage (8/20μs) (UL/CSA)
designation at 100 A
Recognized) 1 time 1 time
Acrms DC
(V) (V) (J) (A) ACrms (V)
(V) (V)
ERZC20EK201Y 20EK201U 200 (185 to 225) 130 170 340 80 8000 118
ERZC20EK241Y 20EK241U 240 (216 to 264) 150 200 395 95 8000 136
ERZC20EK271Y 20EK271U 270 (247 to 303) 175 225 455 100 8000 159
ERZC20EK361Y 20EK361U 360 (324 to 396) 230 300 595 120 8000 209
ERZC20EK391Y 20EK391U 390 (351 to 429) 250 320 650 130 8000 227
ERZC20EK431Y 20EK431U 430 (387 to 473) 275 350 710 140 8000 250
ERZC20EK471Y 20EK471U 470 (423 to 517) 300 385 775 150 8000 272
ERZC20EK511Y 20EK511U 510 (459 to 561) 320 415 845 150 8000 291
ERZC20EK621Y 20EK621U 620 (558 to 682) 385 505 1025 160 8000 350
ERZC20EK681Y 20EK681U 680 (612 to 748) 420 560 1120 175 8000 381
ERZC20EK751Y 20EK751U 750 (675 to 825) 460 615 1240 190 8000 418
ERZC20EK781Y 20EK781U 780 (702 to 858) 485 640 1290 200 8000 440
ERZC20EK821Y 20EK821U 820 (738 to 902) 510 670 1355 215 8000 463
ERZC20EK911Y 20EK911U 910 (819 to 1001) 550 745 1500 240 8000 500
ERZC20EK102Y 20EK102U 1000 (900 to 1100) 625 825 1650 245 8000 568
ERZC20EK112Y 20EK112U 1100 (990 to 1210) 680 895 1815 250 8000 600
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
91
E type / 20, 32 series
Ratings and characteristics (20 series)
●Operating temperature range : ‒40 to 85 ℃ ●Storage temperature range : ‒40 to 110 ℃
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
92
E type / 20 series
Typical characteristics
Voltage vs. Current
(ERZC20EK201(Y) to ERZC20EK511(Y)) Max.Leakage Max.Clamping Voltage
Current
2000
ERZC20EK511(Y)
ERZC20EK471(Y)
ERZC20EK391(Y)
1000 ERZC20EK361(Y)
900
800 ERZC20EK271(Y)
700 ERZC20EK241(Y)
600 ERZC20EK201(Y)
Voltage (V)
500
400
300
200
100
90
80
70
60 Test current waveform
10–6 to 10–3 A: Direct current
50 10–1 to 104 A: 8/20 μs
40
30
10-6 10-5 10-4 10-3 10-2 10-1 100 101 102 103 104 105
Current (A)
(ERZC20EK621(Y) to ERZC20EK112(Y))
Max.Leakage Max.Clamping Voltage
4000 Current
ERZC20EK112(Y)
ERZC20EK102(Y)
3000 ERZC20EK911(Y)
ERZC20EK821(Y)
ERZC20EK781(Y)
ERZC20EK751(Y)
2000 ERZC20EK681(Y)
ERZC20EK621(Y)
1000
Voltage (V)
900
800
700
600
500
400
Test current waveform
300 10–6 to 10–3 A: Direct current
10–1 to 104 A: 8/20 μs
200
10-6 10-5 10-4 10-3 10-2 10-1 100 101 102 103 104 105
Current (A)
Impulse derating curve (Relation be tween impulse width and surge, repetitively)
(ERZC20EK201(Y) to ERZC20EK271(Y)) (ERZC20EK361(Y) to ERZC20EK681(Y)) (ERZC20EK751(Y) to ERZC20EK112(Y))
10000 10000 10000
8000 8000 8000
6000 2 times:5 min. interval 2 times:5 min. interval 6000 2 times:5 min. interval
6000
4000 up to 10 times:2 min. interval up to 10 times:2 min. interval 4000 up to 10 times:2 min. interval
4000 up to 106 times : 10 sec. interval
up to 106 times : 10 sec. interval up to 106 times : 10 sec. interval
Impulse Current(A)
Impulse Current(A)
20 20 20
10 10 10
8 8 8
6 6 6
4 4 4
2 2 2
1 1 1
20 100 1000 10000 20 100 1000 10000 20 100 1000 10000
Impulse Width(μs) Impulse Width(μs)
Impulse Width(μs)
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
93
E type / 32 series
Typical characteristics
Voltage vs. Current
(ERZC32EK201(Y) to ERZC32EK511(Y)) Max.Leakage Max.Clamping Voltage ERZC32EK511(Y)
2000 Current ERZC32EK471(Y)
ERZC32EK431(Y)
ERZC32EK391(Y)
ERZC32EK361(Y)
1000 ERZC32EK271(Y)
900 ERZC32EK241(Y)
800
700 ERZC32EK201(Y)
600
500
400
Voltage (V)
300
200
100
90
80
70 Test current waveform
60 10–6 to 10–3 A: Direct current
50 10–1 to 104 A: 8/20 μs
40
30
10-6 10-5 10-4 10-3 10-2 10-1 100 101 102 103 104 105
Current (A)
(ERZC32EK621(Y) to ERZC32EK112(Y))
ERZC32EK112(Y)
Max.Leakage Max.Clamping Voltage ERZC32EK102(Y)
4000 Current ERZC32EK911(Y)
ERZC32EK821(Y)
3000 ERZC32EK781(Y)
ERZC32EK751(Y)
ERZC32EK681(Y)
ERZC32EK621(Y)
2000
1000
Voltage (V)
900
800
700
600
500
200
10-6 10-5 10-4 10-3 10-2 10-1 100 101 102 103 104 105
Current(A)
Impulse derating curve (Relation be tween impulse width and surge, repetitively)
(ERZC32EK201(Y) to ERZC32EK271(Y)) (ERZC32EK361(Y) to ERZC32EK681(Y)) (ERZC32EK751(Y) to ERZC32EK112(Y))
20000 2 times:5 min. interval 20000 2 times:5 min. interval 20000 2 times:5 min. interval
up to 10 times:2 min. interval 10000 up to 10 times:2 min. interval up to 10 times:2 min. interval
10000 10000
8000 up to 106 times : 10 sec. interval 8000 up to 106 times : 10 sec. interval 8000 up to 106 times : 10 sec. interval
6000 6000 6000
4000 4000 4000
20 20 20
10 10 10
8 8 8
6 6 6
4 4 4
2 2 2
20 100 1000 10000 20 100 1000 10000 20 100 1000 10000
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
94
E type
Performance characteristics
Characteristics Test methods / Description Specifications
Standard test Electrical measurements (initial/after tests) shall be conducted at temperature of 5 to 35
―
condition ℃, relative humidity of maximum 85 %.
The voltage betwen two terminals with the specified measuring current CmA DC applied
Varistor voltage is called VC or VCmA. The measurement shall be made as fast as possible to avoid heat
affection.
Maximum The maximum sinusoidal wave voltage (rms) or the maximum DC
allowable voltage voltage that can be applied continuously.
The maximum voltage between two terminals with the specified
Clamping voltage
standard impulse current (8/20 μs).
To meet the
Rated power The maximum power that can be applied within the specified ambient temperature. specified value
The maximum energy within the varistor voltage change of ±10 % when one impulse of 2
Maximum energy
ms is applied.
The maximum current within the varistor voltage change of ±10 %
Electrical
2times with the standard impulse current (8/20 μs) applied two times with an interval of 5
Maximum
minutes.
peak current
The maximum current within the varistor voltage change of ±10 %
1time
with the standard impulse current (8/20 μs) applied one time.
Temperature
Vc at 70 ℃ - Vc at 20 ℃ 1
coefficient of varistor × × 100(%/℃) 0 to ‒0.05 %/ ℃ max.
Vc at 20 ℃ 50
voltage
The change of VC shall be measured after the impulse current listed below is applied
10000 times continuously with the interval of 10 seconds at room temperature.
Impulse life ΔV1 mA/V1 mA ≦±10%
Series 20 200 A (8/20 μs)
Series 32 300 A (8/20 μs)
Withstanding voltage The commercial frequency voltage of AC 2.5 kV shall be applied between terminals and
(Body insulation) the bottom of the unit for one minute.
Robustness of After gradually applying the load of 49 N (5 kgf) and keeping the
terminations unit fixed for 10 seconds in an axial direction, the terminal shall be visually examined for
Mechanical
+3 +3
3 85
..0
30
..0
4 Room temp. 3 max.
The temperature cycle shown below shall be repeated five times and then stored at room
Temperature cycle temperature and humidity for one to two hours. The change of Vc and mechanical ΔV1 mA/V 1mA ≦ ±5 %
damage shall be examined.
After being continuously applied the Maximum Allowable Voltage
Dry heat load/
at 85±5 ℃ for 500 hours, the specimen shall be stored at room
High temperature ΔV1 mA/V1 mA ≦ ±10 %
temperature and humidity for one to two hours. Thereafter, the change of Vc shall be
load
measured.
The specimen shall be subjected to 40±2 ℃, 90 to 95 %RH for 1000 hours without load
Damp heat/Humidity
and then stored at room temperature and humidity for one to two hours. Thereafter, the ΔV1 mA/V1 mA ≦ ±5 %
(Steady state)
change of Vc shall be measured.
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
95
Varistors (ZNR Surge Absorber)
CK type (UL and CSA Recognized)
Varistors (ZNR Surge Absorber) with Tabs is a heavy duty
type ZNR with very unique tab terminals which bring forth
a higher reliability. These tabs are used as electrical connecting terminals
and also its mounting legs. This type of ZNR is meant for applications in
power supplies or ransient voltage surge suppressor units where large surge
current or high surge energy absorption is required.
Features
●UL and CSA recognized components
●High energy handling capability (210 to 750 joules)
●Large withstanding peak current (20 to 25 kA, 8/20 μs, 2 times)
●Common terminals for electrical connection and mounting
●RoHS compliant
Recommended applications
●Power suppliers for OA, FA, telecommunication or industrial equipment
●Power strips
●Transient voltage surge suppressor units
Related standards
Standard No. UL1449 CSA C22.2 No.269.5
Title Surge protective devices Surge protective devices - Type 5 – Components
■ As for handling precautions and minimum quantity / Packing unit please see related information.
1 2 3 4 5 6 7 8 9 10 11 12
E R Z C C K
Product code Series Element size Type Tolerance Nominal Design No.
varistor voltage
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
96
CK type
Ratings and characteristics
●Operating temperature range : -40 to 85 ℃ ●Operating temperature range : ‒40 to 125 ℃
Varistor Maximum Maximum
Maximum Maximum
Part No. voltage energy peak current
Type allowable clamping
(UL/CSA (2ms) (8/20 μs)
designation at 1mA voltage voltage
Rrecognized) 1 time 1 time 2 times
(V) AC rms(V) DC (V) VXA (V) Ip (A) (J) (kA) (kA)
ERZC32CK201W 32K201U 200 (185 to 225) 130 170 340 200 210 25 20
ERZC32CK241W 32K241U 240 (216 to 264) 150 200 395 200 240 25 20
ERZC32CK271W 32K271U 270 (247 to 303) 175 225 455 200 255 25 20
ERZC32CK361W 32K361U 360 (324 to 396) 230 300 595 200 325 25 20
ERZC32CK391W 32K391U 390 (351 to 429) 250 320 650 200 350 25 20
ERZC32CK431W 32K431U 430 (387 to 473) 275 350 710 200 400 25 20
ERZC32CK471W 32K471U 470 (423 to 517) 300 385 775 200 405 25 20
ERZC32CK511W 32K511U 510 (459 to 561) 320 415 845 200 405 25 20
ERZC32CK621W 32K621U 620 (558 to 682) 385 505 1025 200 415 25 20
ERZC32CK681W 32K681U 680 (612 to 748) 420 560 1120 200 450 25 20
ERZC32CK751W 32K751U 750 (675 to 825) 460 615 1240 200 500 25 20
ERZC32CK781W 32K781U 780 (702 to 858) 485 640 1290 200 520 25 20
ERZC32CK821W 32K821U 820 (738 to 902) 510 670 1355 200 545 25 20
ERZC32CK911W 32K911U 910 (819 to 1001) 550 745 1500 200 600 25 20
ERZC32CK951W 32K951U 950 (855 to 1045) 575 765 1570 200 600 25 20
ERZC40CK201W 40K201U 200 (185 to 225) 130 170 340 250 260 30 25
ERZC40CK241W 40K241U 240 (216 to 264) 150 200 395 250 300 30 25
ERZC40CK271W 40K271U 270 (247 to 303) 175 225 455 250 340 30 25
ERZC40CK361W 40K361U 360 (324 to 396) 230 300 595 250 405 30 25
ERZC40CK391W 40K391U 390 (351 to 429) 250 320 650 250 435 30 25
ERZC40CK431W 40K431U 430 (387 to 473) 275 350 710 250 500 30 25
ERZC40CK471W 40K471U 470 (423 to 517) 300 385 775 250 505 30 25
ERZC40CK511W 40K511U 510 (459 to 561) 320 415 845 250 505 30 25
ERZC40CK621W 40K621U 620 (558 to 682) 385 505 1025 250 515 30 25
ERZC40CK681W 40K681U 680 (612 to 748) 420 560 1120 250 560 30 25
ERZC40CK751W 40K751U 750 (675 to 825) 460 615 1240 250 625 30 25
ERZC40CK781W 40K781U 780 (702 to 858) 485 640 1290 250 650 30 25
ERZC40CK821W 40K821U 820 (738 to 902) 510 670 1355 250 680 30 25
ERZC40CK911W 40K911U 910 (819 to 1001) 550 745 1500 250 750 30 25
ERZC40CK951W 40K951U 950 (855 to 1045) 575 765 1570 250 750 30 25
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
97
CK type
Typical characteristics
Voltage vs. Current
(ERZC32CK201W to ERZC32CK951W)
6000
Max.Leakage
Current
4000 ERZC32CK951W
Max.Clamping Voltage
ERZC32CK911W
ERZC32CK821W
ERZC32CK951W
ERZC32CK751W
ERZC32CK911W
ERZC32CK681W
ERZC32CK821W ERZC32CK621W
ERZC32CK751W ERZC32CK511W
2000
ERZC32CK681W ERZC32CK471W
ERZC32CK621W ERZC32CK431W
ERZC32CK391W
ERZC32CK511W
ERZC32CK361W
ERZC32CK471W
ERZC32CK431W
1000 ERZC32CK391W ERZC32CK271W
Voltage(V)
ERZC32CK361W ERZC32CK241W
800
ERZC32CK201W
600
400
200
100
10-6 10-5 10-4 10-3 10-2 10-1 100 101 102 103 104 105
Current(A)
(ERZC40CK201W to ERZC40CK951W)
6000
Max.Leakage
Current
4000 Max.Clamping Voltage
ERZC40CK951W
ERZC40CK951W ERZC40CK911W
ERZC40CK911W ERZC40CK821W
ERZC40CK821W ERZC40CK751W
ERZC40CK751W ERZC40CK681W
2000 ERZC40CK681W ERZC40CK621W
ERZC40CK621W ERZC40CK511W
ERZC40CK471W
ERZC40CK511W ERZC40CK431W
ERZC40CK471W ERZC40CK391W
ERZC40CK431W
ERZC40CK391W ERZC40CK361W
1000
ERZC40CK361W
ERZC40CK271W
800
ERZC40CK241W
ERZC40CK201W
Voltage(V)
600
400
200 A
100
Test current waveform
ERZC40CK271W 10–6 to 10–3 A: Direct current
80
ERZC40CK241W 10–1 to 104 A: 8/20 μs
ERZC40CK201W
60
10-6 10-5 10-4 10-3 10-2 10-1 100 101 102 103 104 105
Current(A)
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
98
CK type
Application note for safety standards
● Approvals products lists in "Reference Guide to Standard Products."
● UL and VDE : Registered in "Type name", it isn’t registered in "Panasonic Part No."
● CQC : Registered in "Panasonic Part No."
● "Rated Voltages" are specified for UL recognized components in list shown below.
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
99
CK type
Performance characteristics
Characteristics Test methods/description Specifications
Electrical measurements (initial/after tests) shall be conducted at temperature of 5 to
Standard test condition ―
35 ℃, relative humidity of maximum 85 %.
The voltage betwen two terminals with the specified measuring current 1mA DC
Varistor voltage applied is called V1 or V1mA. The measurement shall be made as fast as possible to
avoid heat affection.
Maximum The maximum sinusoidal wave voltage (rms) or the maximum DC
allowable voltage voltage that can be applied continuously.
The maximum voltage between two terminals with the specified
Clamping voltage
Electrical
The maximum energy within the varistor voltage change of ±10 % when one impulse of
Maximum energy
2 ms is applied.
The maximum current within the varistor voltage change of ±10 %
2
with the standard impulse current (8/20 μs) applied two times with an interval of 5
Maximum times minutes
peak current The maximum current within the varistor voltage change of ±10 %
1time
with the standard impulse current (8/20 μs) applied one time.
Robustness of
After gradually applying the load of 19.6 N (2 kgf) and keeping the No remarkable
terminations
unit fixed for 10 seconds, the terminal shall be visually examined for any damage. damage
(Tensile)
After repeadly applying a single harmonic vibration (amplitude:
0.35 mm): double amplitude: 0.7 mm with 1 minute vibration frequency cycles (10 Hz No remarkable
Vibration
to 55 Hz to 10 Hz) to each of three damage
Mechanical
perpendicular directions for 2 hours. Thereafter, the unit shall be visually examined.
Approximately 95 %
After dipping the terminal to a depth of approximately 3 mm from
of the terminals shall
Solderability the body in a soldering bath of 230±5 ℃ for 5.0±0.5 seconds, the terminal shall be
be covered with new solder
visually examined.
uniformly.
The terminal shall be dipped into a soldering bath having a
Resistance to temperature of 350±10 ℃ to a point 4.0±0.8 mm from the body
ΔV1 mA/V1 mA ≦ ±5 %
soldering heat of the unit and then be held there for 3.0±0.5 seconds. The change of Vc and
mechanical damage shall be examined.
The specimen shall be subjected to 125±2 ℃ for 500 hours
Dry heat/ high
in a thermostatic bath without load and then stored at room
temperature
temperature and humidity for one to two hours. Thereafter, the change of Vc shall be
storage
measured. ΔV1 mA/V1 mA ≦ ±5 %
The specimen shall be subjected to 40±2 ℃, 90 to 95 %RH for 1000 hours without
Damp heat/humidity
load and then stored at room temperature and humidity for one to two hours.
(Steady State)
Thereafter, the change of Vc shall be measured.
The temperature cycle shown below shall be repeated five times and then stored at
room temperature and humidity for one to two hours. The change of Vc and
Environmental
Part No., quantity and country of origin are designated on outer packages in English.
※ Please contact local sales office about packing specifications.
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
100
Matters to Be Observed When Using This Product
Safety measures
An abnormal state for varistors (ZNR surge absorbers) of P-type, J-type, G-type, an arrestor box, and varistors for thyristors
(hereinafter "the product" or "the surge absorber") that results from a problem with service conditions (materials used, the
surrounding environment, power conditions, circuit conditions, etc.) may cause a fire accident, electric shock accident, burn
accident, or product failure. Matters to note when handling this product will hereinafter be described. What is described
below should be checked sufficiently before the product is used.
■ Take the following measures in order to avoid an accident caused by expected phenomenon.
(1) Destruction of the surge absorber may scatter its fractured pieces around. To protect other elements from these
pieces, set product in a case or shield it with a cover.
(2) Do not place the surge absorber near combustible materials (vinyl cable, resin mold, etc.). If avoiding the vicinity
of combustible materials is difficult, protect the combustible material with an incombustible cover.
(3) Surge absorber placed between lines
① When the surge absorber is placed between lines, connect a normal type current fuse in series with the surge
absorber.
② The P-type surge absorber has a built-in temperature fuse but its breaking capacity is low (0.3 A). For this
reason, a current fuse needs to be connected in series with the surge absorber.
(4) Surge absorber placed between a line and the ground
① When the surge absorber is placed between a line and the ground, even if the surge absorber short-circuits,
ground resistance will remain in the section between the line and the ground, leaving a possibility that the
current fuse won’t blow, in which case the outer sheath resin of the surge absorber may generate smoke or
ignite due to current flow. To prevent such a case, place an earth leakage breaker in a location closer to the
power supply than the surge absorber. When not using an earth leakage breaker, use a current fuse and
temperature fuse in series with each other.
* See Table 1 in the "Circuit design and circuit board design" section.
② When the surge absorber is placed between a live part and a metal case, it may cause electric shock if the
surge absorber short-circuits. To avoid this, ground the metal case or shield it to prevent direct contact with the
metal case.
■ Do not touch a live part of the surge absorber. You may get an electric shock when touching it. In case the surge
absorber should short-circuit and generate smoke or ignite, immediately cut off current flow to the surge absorber.
■ An unexpected sharp rise in the working voltage, an incoming excessive surge, etc., may cause the surge absorber to
generate smoke or ignite.
In such a case, fire spreading through the device should be prevented to avoid expanded damage. To achieve this,
take a multi-protection measure, such as adopting fire-resistant materials that make up the outer shell components
and structural materials.
■ Do not use the surge absorber in which direct sunlight hits the surge absorber or near a heating element where the
temperature of the surge absorber would rise above its working temperature.
■ Do not use the surge absorber in a place where the surge absorber is exposed to wind or rain or a highly humid place
where steam is emitted or dew concentrates.
■ Do not use the surge absorber in a place filled with dust or salt, in an atmosphere contaminated with a corrosive gas,
etc., or in liquids such as water, oil, chemical, or organic solvents.
■ Do not wash the surge absorber with a solvent (thinner, acetone, etc.) that damages the outer sheath resin.
30-Jun-23
101
Matters to Be Observed When Using This Product
■ We recommend you to carry out a maintenance check of the varistor to measure its varistor voltage once every two years.
The varistor should be replaced when a difference between the current varistor voltage (1 mA V) and the initial varistor
voltage exceeds ±10%.
■ Choose a surge absorber whose maximum allowable circuit voltage has a margin relative to the maximum voltage range
including source voltage fluctuations.
■ When surges are applied intermittently to the surge absorber at short intervals (when pulses of voltages are applied in a
noise simulator test, etc.), make sure that the surge power does not exceed the maximum average pulse power of the
surge absorber.
Processing conditions
■ Do not apply vibration, impact (drop impact, etc.), or pressure strong enough to crack the outer sheath resin or absorber
body of the surge absorber.
■ When coating the surge absorber with a resin or embedding it in a resin mold, avoid using a resin that degrades the
surge absorber.
■ Do not bend the surge absorber or apply force thereto close to the insulation cover of the lead terminal.
■ Do not keep the product in a high-temperature or high-humidity condition. Keep the surge absorber in a room with
a temperature of 40 ℃ or lower and a relative humidity of 75% or lower and use the surge absorber within two years of
storage.
■ Keep the surge absorber in a place where no corrosive gas atmosphere (hydrogen sulfide, sulfurous acid, chlorine,
ammonia, etc.) is present.
■ Keep the surge absorber in a place where the surge absorber is protected from direct sunlight, dew concentration, etc.
30-Jun-23
102
Varistors (ZNR Surge Absorber)
P type
Features
●RoHS compliant
Recommended applications
Protection of semiconductor devices used for the electronic equipment includes:
●Broadcasting, communication equipment
●Traffic or railroad systems
●Automatic control devices for power distribution
●Waterworks
●Protection of motor coils, vacuum switches
■ As for handling precautions and minimum quantity / Packing unit please see related information.
1 2 3 4 5 6 7 8 9 10 11 12
E R Z A P K
Product code Series Element size Type Tolerance Nominal Design No.
varistor voltage
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
103
P type
Typical characteristics
Voltage vs. Current (ERA20PK251 to ERZA20PK102)
Max.Leakage
4000 Current Max.Clamping Voltage
3000
2000
1000
900
800
700
Voltage (V)
600
500
400
300
200
100
90 Test current waveform
80 10–6 to 10–3 A: Direct current
70 10–1 to 104 A: 8/20 μs
60
10-6 10-5 10-4 10-3 10-2 10-1 1 10 102 103 104 105
Current (A)
47
3
7
ø30
Mounting pitch
NP
66
16
78
88
φ9
Mounting hole
ø4.5
M4
Life indicator
Unit : mm
Part No., quantity and country of origin are designated on outer packages in English.
※ Please contact local sales office about packing specifications.
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
104
Varistors (ZNR Surge Absorber)
J type
Varistors (ZNR Surge Absorber), Type J, are designed especially for surge
protection of industrial equipment from high energy transient voltages which are
generated by switching of the inductive loads such as DC magnet relays or
transformers.
Features
●Low clamping voltage
●Fast response to steep impulse voltage
●A bilateral and symmetrical V-I characteristic curve
●Higher energy handling capability (5000 to 44000 J)
●No follow-on current
●Wide product range [Varistor Voltage] 500 V to 1300 V
●RoHS compliant
Recommended applications
●Suppression of volume surges such as those produced by switching of DC lifting magnets and
within equipment in railroad vehicles
●Protection of a current transformer from overheating caused with secondary opening
●Protection of thyristors or diodes employed in power supply equipment
■ As for handling precautions and minimum quantity / Packing unit please see related information.
1 2 3 4 5 6 7 8 9 10 11 12
E R Z A J K
Product code Series Element size Type Tolerance Nominal Design No.
varistor voltage
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
105
J type
Ratings and characteristics
●Operating temperature range : -25 to 70 ℃ ●Storage temperature range : ‒25 to 110 ℃
Maximum Typical
Varistor Maximum Maximum
clamping Maximum capacitance
voltage allowable peak current
Part No. voltage energy (Reference)
at 1mA voltage (4/10 μs, 2 times)
at 100A at 1 kHz
(V) ACrms (V) DC (V) (V) (J) (kA) (pF)
ERZA80JK561 5000 80 9800
Typical characteristics
Voltage vs. Current Impulse Derating (Relation between
impulse width and impulse current multiple)
106
Max.Leakage
Current
Max.Clamping Voltage
5,000
105
1.0
3,000 (100 μs
0 T
to 1s)
2,000
Voltage(V)
104
1.0
0.5
Impulse Current(A)
1,000 0 T
103 (10 to 40 μs)
700
500
102
300
Test current waveform
200 10–6 to 10–3 A: Direct current
10–1 to 104 A: 8/20 μs 10
100
10-6 10-5 10-4 10-3 10-2 10-1 100 101 102 103 104 105
1
Current(A)
0.1
0.01
10 μs 100 μs 1 ms 10 ms 100 ms 1s
Impulse Width
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
106
J type
Dimensions in mm (not to scale)
ERZA80JK□□□ ERZA80JK□□□B
7±1.0
7±1.0
Terminal Terminal
Terminal Terminal
□110
□110
140
140
85
85
39
26
39
26
3 18
3 18
40±0.4 40±0.4
62 62
ERZA80JK□□□A ERZA80JK□□□C
M6 A 5.5 mm2 Terminal Name plate M6 A 5.5 mm2 Terminal Name plate
7±1.0 96±0.2 7±1.0 96±0.2
7±1.0
7±1.0
□110
□110
140
140
85
85
Bar Hole Bar Hole
B B
8.5 8.5
C C
ZNR connection
39
39
26
ZNR connection
26
3 18
3 18
40±0.4 40±0.4
62 62
Unit : mm
Part No. A B C
ERZA80JK561 14.0 125.0±4.0 161.0±4.0
ERZA80JK561A 14.0 138.0±8.0 174.0±8.0
ERZA80JK561B 40.0 151.0±8.0 187.0±8.0
ERZA80JK561C 40.0 164.0±8.0 200.0±8.0
ERZA80JK112 19.0 130.0±4.0 166.0±4.0
ERZA80JK112A 19.0 148.0±8.0 184.0±8.0
ERZA80JK112B 56.0 167.0±8.0 203.0±8.0
ERZA80JK112C 56.0 185.0±8.0 221.0±8.0
ERZA80JK122 21.0 132.0±4.0 168.0±4.0
ERZA80JK122A 21.0 152.0±8.0 188.0±8.0
ERZA80JK122B 61.0 172.0±8.0 208.0±8.0
ERZA80JK122C 61.0 192.0±8.0 228.0±8.0
Part No., quantity and country of origin are designated on outer packages in English.
※ Please contact local sales office about packing specifications.
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
107
Varistors (ZNR Surge Absorber)
G type
High energy transient over voltages generated by switching on/off of a vacuum relay in
power distribution line can cause insulation breakdown of high voltage electronic
equipment/devices and power cables etc…
Varistors (ZNR Surge Absorber), Type G are gapless type arresters using sintered bodies
of zinc-oxide and are characterized by the excellent characteristics of high energy handling
capability, fast response time and low clamp ratio etc... The ZNR and G have wide
applications for protection of high-voltage motors, tranformers, rectifiers and anticorrosion
layers of powercables from high energy transient overvoltages/surges.
Features
●RoHS compliant
Recommended applications
●Protection of high voltage motors, transformers or rectifiers from switching surges
●Switching surge absorption in vacuum circuit interrupters
●Protection of anti-corrosion layer of under ground electric power cable from induced lightning or switching surges
Note : Ask our factory for Product Specification before use.
■ As for handling precautions and minimum quantity / Packing unit please see related information.
Mounting hole
2-ø8.5
105
160
Mounting hole
145
200
2-ø8.5
22
N.P
28
80 10 16
22
N.P
Mounting pitch
28
16
20.0±0.5 100 10
Mounting pitch
ø54 Unit : mm
20.0±0.5
ø54
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
108
G type
Ratings and characteristics
●Operating temperature range : 0 to 50 ℃ ●Storage temperature range : ‒10 to 70 ℃
Part No.
ERZA48GK502
Characteristics
Across the
Connection
Anti-corrosion layers
Varistor voltage (V1 mA) 5.0 kV±0.5 kV
Maximum clamping voltage
14 kV at V23 kA
(8/20 µs)
Maximum peak current
21 kA at 100 times
(8/20 µs )
ERZA48GK502
15 85 15
ø14
32
22
33 49 33 ø70
Unit : mm
Part No., quantity and country of origin are designated on outer packages in English.
※ Please contact local sales office about packing specifications.
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
109
Varistors (ZNR Surge Absorber)
Surge absorber units
The Surge Absorber Unit contains Y, Δ or p connected ZNRs surge absorbers (and, if necessary, a circuit
breaker) in a box.
These Surge Absorber Units are designed for surge protection of industrial electric equipment where
reliability is essential.
Recommended applications
Surge Protection of
● Railway/traffi c signal control systems
● Distribution line control systems
● Broadcasting systems, communication systems
● Measuring instruments
● Controllers of low voltage distribution line
● Controllers of waterworks
■ As for handling precautions and minimum quantity / Packing unit please see related information.
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
hould a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
110
Surge absorber units
ZNR Surge absorber units
Maximum
Rated
Application peak Part No. Dimensions Connection
voltage
current
Equipmen
(Line to line and Line 5000 A DC 48 V ERZA5F680AC D
to ground use)
DC 80 V ERZA5F101AC
DC 100 V ERZA5F201ACA
Type D (other : Type E)
DC 12 V ERZA5F220BC Coil: 1 mH max.
Max. continuous current: 0.6 A
DC 24 V ERZA5F390BC
For signal system
Equipmen
(Line to line use 5000 A DC 48 V ERZA5F680BC D
only)
DC 80 V ERZA5F101BC
DC 100 V ERZA5F201BC
Type D (other : Type E)
3-ø6
Mounting pitc
160
135
Mounting pitch
85
83
(D)
105 Unit:mm
Part No., quantity and country of origin are designated on outer packages in English.
※ Please contact local sales office about packing specifications.
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
hould a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
111
Varistors (ZNR Surge Absorber)
For thyristor protection
E type
J type
Features
● RoHS compliant
Recommended applications
● Surge protection of thyristor power controllers
● Surge protection of thyristor power sources
■ As for handling precautions and minimum quantity / Packing unit please see related information.
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
112
For thyristor protection / E, J type
Dimensions in mm (not to scale) (E type)
ISO
24 M4
4.3
L
W
12
5
ZNR Dot
H
Part No.
Date code
14
Unit : mm
Part No. W H L
ERZC20EK□□□P 48±1 42±1 39±1
ERZC32EK□□□P 60±1 55±1 51±1
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
113
For thyristor protection / E, J type
Ratings and characteristics (J type)
●Operating temperature range : ‒40 to 70 ℃ ●Storage temperature range : ‒40 to 110 ℃
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
114
For thyristor protection / E, J type
Dimensions in mm (not to scale) (J type)
104±1
104±1
M4 M4
141±1
60
122±1
60
N.P. N.P.
C
A A 6.5
6.5
3
B B
14 3
14
22
22
20 20
46 46
Unit : mm
Part No., quantity and country of origin are designated on outer packages in English.
※ Please contact local sales office about packing specifications.
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately. 14-Dec-20
115
Safty Precautions
When using our products, no matter what sort of equipment they might be used for,
be sure to confirm the applications and environmental conditions with our specifications in advance.