MAGNETIC PARTICLE INSPECTION REPORT
Effective Date: 01-May-23

Customer: GDI Rig Name: Al Zubarah Location: Qatar Offshore

P.O. No: PON599590 Job No: ALL-ME-6281 Report No: ME-6281-MPI-MP-001

Allrig Procedure: I-OPE-NDT-003 Surface: As Cleaned

Equipment: Electro Magnetic Yoke Equipment Serial No: IN22-0973

Magnetic
Ultra Violet Light: No Yes Coil: No
Flow:
Electromagnet/Pull 10lbs: Yes Voltage: 110V Current Flow: AC Longitudinal: Yes

Other: N/A Pole Spacing: 4" - 6" Circular: N/A


Magnaflux
Flux Indicator: Light Type: Background: Wet Indicator: Magnaflux 7HF
WCP
Batch No: 211107 Fl/Sample at:

Berthold: Natural: No Dry Indicator: UV: 0.4 at 100ml

Heat Temp: Visible: 2.4 at 100ml

Burmah Strip: Yes Artificial: Yes Batch No: Batch No: 221004

Manufacturer: NOV Item: Bull Gear

Drawing No: N/A Work Area: Mud Pump Room

Material: Carbon Steel Specification: API RP8B (CAT III) Dimension: NA

Identification / Serial No: 11469-H (Mud Pump-02) SWL: N/A Quantity: 1

Comments: Visual inspection was carried out prior to MPI.


Areas Inspected: MPI was carried out on all accessible areas. (As Mentioned in the NOV procedure)

Results: No relavant indication was noted when the time of inspection.

Recommendations: Acceptable to the specfications

PHOTO HERE PHOTO HERE

Inspector: S.Venkat Signature:

Qualification: PCN-LEVEL 2-MPI Date: 31-04-2024

For Client use: For Certifying Authority use:

This document shall not be reproduced except in full, without the written approval of an Allrig Senior Representative.
Page 1 of 9
Form Number: F-OPE-009a
Document Owner: OPS-NDT
Revision: 4
MAGNETIC PARTICLE INSPECTION REPORT
Effective Date: 01-May-23

Customer: GDI Rig Name: Al Zubarah Location: Qatar Offshore

P.O. No: PON599590 Job No: ALL-ME-6281 Report No: ME-6281-MPI-MP-002

Allrig Procedure: I-OPE-NDT-003 Surface: As Cleaned

Equipment: Electro Magnetic Yoke Equipment Serial No: IN22-0973

Magnetic
Ultra Violet Light: No Yes Coil: No
Flow:
Electromagnet/Pull 10lbs: Yes Voltage: 110V Current Flow: AC Longitudinal: Yes

Other: N/A Pole Spacing: 4" - 6" Circular: N/A


Magnaflux
Flux Indicator: Light Type: Background: Wet Indicator: Magnaflux 7HF
WCP
Batch No: 211107 Fl/Sample at:

Berthold: Natural: No Dry Indicator: UV: 0.4 at 100ml

Heat Temp: Visible: 2.4 at 100ml

Burmah Strip: Yes Artificial: Yes Batch No: Batch No: 221004

Manufacturer: NOV Item: Crank Shaft

Drawing No: N/A Work Area: Mud Pump Room

Material: Carbon Steel Specification: API RP8B (CAT III) Dimension: NA

Identification / Serial No: 11469-H (Mud Pump-02) SWL: N/A Quantity: 1

Comments: Visual inspection was carried out prior to MPI.


Areas Inspected: MPI was carried out on all accessible areas. (As Mentioned in the NOV procedure)

Results: No relavant indication was noted when the time of inspection.

Recommendations: Acceptable to the specfications

PHOTO HERE PHOTO HERE

Inspector: S.Venkat Signature:

Qualification: PCN-LEVEL 2-MPI Date: 31-04-2024

For Client use: For Certifying Authority use:

This document shall not be reproduced except in full, without the written approval of an Allrig Senior Representative.
Page 2 of 9
Form Number: F-OPE-009a
Document Owner: OPS-NDT
Revision: 4
MAGNETIC PARTICLE INSPECTION REPORT
Effective Date: 01-May-23

Customer: GDI Rig Name: Al Zubarah Location: Qatar Offshore

P.O. No: PON599590 Job No: ALL-ME-6281 Report No: ME-6281-MPI-MP-003

Allrig Procedure: I-OPE-NDT-003 Surface: As Cleaned

Equipment: Electro Magnetic Yoke Equipment Serial No: IN22-0973

Magnetic
Ultra Violet Light: No Yes Coil: No
Flow:
Electromagnet/Pull 10lbs: Yes Voltage: 110V Current Flow: AC Longitudinal: Yes

Other: N/A Pole Spacing: 4" - 6" Circular: N/A


Magnaflux
Flux Indicator: Light Type: Background: Wet Indicator: Magnaflux 7HF
WCP
Batch No: 211107 Fl/Sample at:

Berthold: Natural: No Dry Indicator: UV: 0.4 at 100ml

Heat Temp: Visible: 2.4 at 100ml

Burmah Strip: Yes Artificial: Yes Batch No: Batch No: 221004

Manufacturer: NOV Item: Pinion Shaft/Gear

Drawing No: N/A Work Area: Mud Pump Room

Material: Carbon Steel Specification: API RP8B (CAT III) Dimension: NA

Identification / Serial No: 11469-H (Mud Pump-02) SWL: N/A Quantity: 1

Comments: Visual inspection was carried out prior to MPI.


Areas Inspected: MPI was carried out on all accessible areas. (As Mentioned in the NOV procedure)

Results: No relavant indication was noted when the time of inspection.

Recommendations: Acceptable to the specfications

PHOTO HERE PHOTO HERE

Inspector: S.Venkat Signature:

Qualification: PCN-LEVEL 2-MPI Date: 31-04-2024

For Client use: For Certifying Authority use:

This document shall not be reproduced except in full, without the written approval of an Allrig Senior Representative.
Page 3 of 9
Form Number: F-OPE-009a
Document Owner: OPS-NDT
Revision: 4
MAGNETIC PARTICLE INSPECTION REPORT
Effective Date: 01-May-23

Customer: GDI Rig Name: Al Zubarah Location: Qatar Offshore

P.O. No: PON599590 Job No: ALL-ME-6281 Report No: ME-6281-MPI-MP-004

Allrig Procedure: I-OPE-NDT-003 Surface: As Cleaned

Equipment: Electro Magnetic Yoke Equipment Serial No: IN22-0973

Magnetic
Ultra Violet Light: No Yes Coil: No
Flow:
Electromagnet/Pull 10lbs: Yes Voltage: 110V Current Flow: AC Longitudinal: Yes

Other: N/A Pole Spacing: 4" - 6" Circular: N/A


Magnaflux
Flux Indicator: Light Type: Background: Wet Indicator: Magnaflux 7HF
WCP
Batch No: 211107 Fl/Sample at:

Berthold: Natural: No Dry Indicator: UV: 0.4 at 100ml

Heat Temp: Visible: 2.4 at 100ml

Burmah Strip: Yes Artificial: Yes Batch No: Batch No: 221004

Manufacturer: NOV Item: Pony Rod-01

Drawing No: N/A Work Area: Mud Pump Room

Material: Carbon Steel Specification: API RP8B (CAT III) Dimension: NA

Identification / Serial No: 11469-H (Mud Pump-02) SWL: N/A Quantity: 1

Comments: Visual inspection was carried out prior to MPI.


Areas Inspected: MPI was carried out on all accessible areas. (As Mentioned in the NOV procedure)

Results: No relavant indication was noted when the time of inspection.

Recommendations: Acceptable to the specfications

Inspector: S.Venkat Signature:

Qualification: PCN-LEVEL 2-MPI Date: 31-04-2024

For Client use: For Certifying Authority use:

This document shall not be reproduced except in full, without the written approval of an Allrig Senior Representative.
Page 4 of 9
Form Number: F-OPE-009a
Document Owner: OPS-NDT
Revision: 4
MAGNETIC PARTICLE INSPECTION REPORT
Effective Date: 01-May-23

Customer: GDI Rig Name: Al Zubarah Location: Qatar Offshore

P.O. No: PON599590 Job No: ALL-ME-6281 Report No: ME-6281-MPI-MP-005

Allrig Procedure: I-OPE-NDT-003 Surface: As Cleaned

Equipment: Electro Magnetic Yoke Equipment Serial No: IN22-0973

Magnetic
Ultra Violet Light: No Yes Coil: No
Flow:
Electromagnet/Pull 10lbs: Yes Voltage: 110V Current Flow: AC Longitudinal: Yes

Other: N/A Pole Spacing: 4" - 6" Circular: N/A


Magnaflux
Flux Indicator: Light Type: Background: Wet Indicator: Magnaflux 7HF
WCP
Batch No: 211107 Fl/Sample at:

Berthold: Natural: No Dry Indicator: UV: 0.4 at 100ml

Heat Temp: Visible: 2.4 at 100ml

Burmah Strip: Yes Artificial: Yes Batch No: Batch No: 221004

Manufacturer: NOV Item: Sub Rod-01

Drawing No: N/A Work Area: Mud Pump Room

Material: Carbon Steel Specification: API RP8B (CAT III) Dimension: NA

Identification / Serial No: 11469-H (Mud Pump-02) SWL: N/A Quantity: 1

Comments: Visual inspection was carried out prior to MPI.


Areas Inspected: MPI was carried out on all accessible areas. (As Mentioned in the NOV procedure)

Results: No relavant indication was noted when the time of inspection.

Recommendations: Acceptable to the specfications

Inspector: S.Venkat Signature:

Qualification: PCN-LEVEL 2-MPI Date: 31-04-2024

For Client use: For Certifying Authority use:

This document shall not be reproduced except in full, without the written approval of an Allrig Senior Representative.
Page 5 of 9
Form Number: F-OPE-009a
Document Owner: OPS-NDT
Revision: 4
MAGNETIC PARTICLE INSPECTION REPORT
Effective Date: 01-May-23

Customer: GDI Rig Name: Al Zubarah Location: Qatar Offshore

P.O. No: PON599590 Job No: ALL-ME-6281 Report No: ME-6281-MPI-MP-006

Allrig Procedure: I-OPE-NDT-003 Surface: As Cleaned

Equipment: Electro Magnetic Yoke Equipment Serial No: IN22-0973

Magnetic
Ultra Violet Light: No Yes Coil: No
Flow:
Electromagnet/Pull 10lbs: Yes Voltage: 110V Current Flow: AC Longitudinal: Yes

Other: N/A Pole Spacing: 4" - 6" Circular: N/A


Magnaflux
Flux Indicator: Light Type: Background: Wet Indicator: Magnaflux 7HF
WCP
Batch No: 211107 Fl/Sample at:

Berthold: Natural: No Dry Indicator: UV: 0.4 at 100ml

Heat Temp: Visible: 2.4 at 100ml

Burmah Strip: Yes Artificial: Yes Batch No: Batch No: 221004

Manufacturer: NOV Item: Pony Rod-02

Drawing No: N/A Work Area: Mud Pump Room

Material: Carbon Steel Specification: API RP8B (CAT III) Dimension: NA

Identification / Serial No: 11469-H (Mud Pump-02) SWL: N/A Quantity: 1

Comments: Visual inspection was carried out prior to MPI.


Areas Inspected: MPI was carried out on all accessible areas. (As Mentioned in the NOV procedure)

Results: No relavant indication was noted when the time of inspection.

Recommendations: Acceptable to the specfications

Inspector: S.Venkat Signature:

Qualification: PCN-LEVEL 2-MPI Date: 31-04-2024

For Client use: For Certifying Authority use:

This document shall not be reproduced except in full, without the written approval of an Allrig Senior Representative.
Page 6 of 9
Form Number: F-OPE-009a
Document Owner: OPS-NDT
Revision: 4
MAGNETIC PARTICLE INSPECTION REPORT
Effective Date: 01-May-23

Customer: GDI Rig Name: Al Zubarah Location: Qatar Offshore

P.O. No: PON599590 Job No: ALL-ME-6281 Report No: ME-6281-MPI-MP-007

Allrig Procedure: I-OPE-NDT-003 Surface: As Cleaned

Equipment: Electro Magnetic Yoke Equipment Serial No: IN22-0973

Magnetic
Ultra Violet Light: No Yes Coil: No
Flow:
Electromagnet/Pull 10lbs: Yes Voltage: 110V Current Flow: AC Longitudinal: Yes

Other: N/A Pole Spacing: 4" - 6" Circular: N/A


Magnaflux
Flux Indicator: Light Type: Background: Wet Indicator: Magnaflux 7HF
WCP
Batch No: 211107 Fl/Sample at:

Berthold: Natural: No Dry Indicator: UV: 0.4 at 100ml

Heat Temp: Visible: 2.4 at 100ml

Burmah Strip: Yes Artificial: Yes Batch No: Batch No: 221004

Manufacturer: NOV Item: Sub Rod-02

Drawing No: N/A Work Area: Mud Pump Room

Material: Carbon Steel Specification: API RP8B (CAT III) Dimension: NA

Identification / Serial No: 11469-H (Mud Pump-02) SWL: N/A Quantity: 1

Comments: Visual inspection was carried out prior to MPI.


Areas Inspected: MPI was carried out on all accessible areas. (As Mentioned in the NOV procedure)

Results: No relavant indication was noted when the time of inspection.

Recommendations: Acceptable to the specfications

Inspector: S.Venkat Signature:

Qualification: PCN-LEVEL 2-MPI Date: 31-04-2024

For Client use: For Certifying Authority use:

This document shall not be reproduced except in full, without the written approval of an Allrig Senior Representative.
Page 7 of 9
Form Number: F-OPE-009a
Document Owner: OPS-NDT
Revision: 4
MAGNETIC PARTICLE INSPECTION REPORT
Effective Date: 01-May-23

Customer: GDI Rig Name: Al Zubarah Location: Qatar Offshore

P.O. No: PON599590 Job No: ALL-ME-6281 Report No: ME-6281-MPI-MP-008

Allrig Procedure: I-OPE-NDT-003 Surface: As Cleaned

Equipment: Electro Magnetic Yoke Equipment Serial No: IN22-0973

Magnetic
Ultra Violet Light: No Yes Coil: No
Flow:
Electromagnet/Pull 10lbs: Yes Voltage: 110V Current Flow: AC Longitudinal: Yes

Other: N/A Pole Spacing: 4" - 6" Circular: N/A


Magnaflux
Flux Indicator: Light Type: Background: Wet Indicator: Magnaflux 7HF
WCP
Batch No: 211107 Fl/Sample at:

Berthold: Natural: No Dry Indicator: UV: 0.4 at 100ml

Heat Temp: Visible: 2.4 at 100ml

Burmah Strip: Yes Artificial: Yes Batch No: Batch No: 221004

Manufacturer: NOV Item: Pony Rod-03

Drawing No: N/A Work Area: Mud Pump Room

Material: Carbon Steel Specification: API RP8B (CAT III) Dimension: NA

Identification / Serial No: 11469-H (Mud Pump-02) SWL: N/A Quantity: 1

Comments: Visual inspection was carried out prior to MPI.


Areas Inspected: MPI was carried out on all accessible areas. (As Mentioned in the NOV procedure)

Results: No relavant indication was noted when the time of inspection.

Recommendations: Acceptable to the specfications

Inspector: S.Venkat Signature:

Qualification: PCN-LEVEL 2-MPI Date: 31-04-2024

For Client use: For Certifying Authority use:

This document shall not be reproduced except in full, without the written approval of an Allrig Senior Representative.
Page 8 of 9
Form Number: F-OPE-009a
Document Owner: OPS-NDT
Revision: 4
MAGNETIC PARTICLE INSPECTION REPORT
Effective Date: 01-May-23

Customer: GDI Rig Name: Al Zubarah Location: Qatar Offshore

P.O. No: PON599590 Job No: ALL-ME-6281 Report No: ME-6281-MPI-MP-009

Allrig Procedure: I-OPE-NDT-003 Surface: As Cleaned

Equipment: Electro Magnetic Yoke Equipment Serial No: IN22-0973

Magnetic
Ultra Violet Light: No Yes Coil: No
Flow:
Electromagnet/Pull 10lbs: Yes Voltage: 110V Current Flow: AC Longitudinal: Yes

Other: N/A Pole Spacing: 4" - 6" Circular: N/A


Magnaflux
Flux Indicator: Light Type: Background: Wet Indicator: Magnaflux 7HF
WCP
Batch No: 211107 Fl/Sample at:

Berthold: Natural: No Dry Indicator: UV: 0.4 at 100ml

Heat Temp: Visible: 2.4 at 100ml

Burmah Strip: Yes Artificial: Yes Batch No: Batch No: 221004

Manufacturer: NOV Item: Sub Rod-03

Drawing No: N/A Work Area: Mud Pump Room

Material: Carbon Steel Specification: API RP8B (CAT III) Dimension: NA

Identification / Serial No: 11469-H (Mud Pump-02) SWL: N/A Quantity: 1

Comments: Visual inspection was carried out prior to MPI.


Areas Inspected: MPI was carried out on all accessible areas. (As Mentioned in the NOV procedure)

Results: No relavant indication was noted when the time of inspection.

Recommendations: Acceptable to the specfications

Inspector: S.Venkat Signature: