Manual Usbr232c
Manual Usbr232c
2016.11
Rev. 1.0
Contents
1.Introduction ................................................................ 1
1-1. Overview ................................................................................ 1
1-2. Package Contents .................................................................. 1
1-3. System Requirements and Restrictions............................... 1
1-4. DB9(RS-232C) connector Pin Assignment........................... 2
4. Specifications ............................................................. 14
*All trademarks and logos are the properties of their respective holders.
*The specifications and pictures are subject to change without notice.
1.Introduction
1-1. Overview
●USB60FPW is a USB to serial converter with 5V power supply.
Compatible with Universal Serial Bus specifications Rev. 1.1.
● Up to 230.4Kbps data transfer rate.
● Standard USB (A type Male).
Easy to connect PC.
●Virtual COM port driver
USB60FPW can be used with PWR(from USB port)
FTDI’s VCP drivers to provide a
COM port on a PC.
●LED indicators.
USB60FPW has “PWR/TXD/RXD”
LED indicators for monitoring TXD(Host to device)
communication status.
PWR: power / TXD: transmit / RXD(Device to host)
RXD: receive
Operating System
● Windows 10, Windows 8.1, Windows 8, Windows7, Windows Vista
● Windows Server 2012 R2, Windows Server 2012, Windows Server 2008 R2,
Windows Server 2008
1
1-4. DB9(RS-232C) connector Pin Assignment
The pin assignment of the connector is below:
This DB9pin connector is compatible with ANSI/EIA/TIA-574 specifications.
12345
Anchor [#4-40]
For using inch screw
6789
9Pin provides 5V to devices
D-Sub9pin Male
※As 5V outputs to RS-232C devices, the RS-232C devices must
be compatible with this 5V output. Otherwise, the RS-232C
may get damaged.
Signal Direction
Pin# Meaning
Name DTE – DCE.
1 DCD <--- Data Carrier Detected
2 RXD <--- Received Data
3 TXD ---> Transmitted Data
4 DTR ---> Data Terminal Ready
5 GND - Signal Ground
6 DSR <--- Data Set Ready
7 RTS ---> Request to Send
8 CTS <--- Clear to Send
9 5V OUT ---> Output 5V power supply to devices
2
2. Installation on Windows PC
Please make sure that the Windows PC meets the following specifications:
USB port(Standard-USB A) is available
Windows version is Vista or later
1) Insert the setup CD-ROM for the REX-USB60FPW into your CD-ROM drive.
Find the [Setup] folder at the CD that contains the USB60FPW_Setup.exe
Double click USB60FPW_Setup.exe.
2) A “User Account Control” dialog box may appear.
Click [Yes] to proceed with the installation.
3
3) The InstallShield Wizard for RATOC REX-USB60FPW Installer will start.
Click [Next] to proceed with the installation.
4
5) A “Windows Security” dialog box will appear.
Click [Install] to proceed with the installation.
5
7) The installer will automatically be complete.
6
2-2. Confirmation
To confirm the installation has finished successfully,
oen the Device Manager and select “View > Devices by Connection”.
If this string shows without yellow “!” mark, the installation is made
successfully.
7
2-3. Uninstallation on Windows 10/8.1/8/7/Vista
Server 2012 R2/Server 2012/Server 2008 R2/Server 2008
Open the [Program and Features] at [Control Panel].
Select the [RATOC REX-USB60FPW Installer] and click [Uninstall].
8
The uninstallation will automatically be complete.
9
3. Application note
3-1. Setting USB transfer size and latency time
※As this product will be used at default setting, so you do not need to change the
below setting unless special issue comes out.
10
At the below screen(Advanced setting for COMx), you can find [USB Transfer
Sizes] and [Latency Timer].
Here is an explanation for these 2 settings.
[USB Transfer Sizes] and [Latency Timer] are used to set parameters on receipt
data function of USB60FPW.
Once USB60FPW detects the following event, it will transfer received data from
RS-232C to host via USB.
1) Transfer buffer of 384 bytes inside of USB60FPW becomes full.
2) Line condition for CTS#/DSR#/DCD#/RI# of RS232C gets changed.
3) Detection of event character in received data from RS-232C.
4) Latency time(Default time is 16msec) times out.
11
Regarding data transfer less than 384 bytes, latency time set at the [Latency
Timer] section happens, while much data over than 384 bytes transfer, transfer
will start as soon as transfer buffer of 384 bytes becomes full, and latency time
set at the [Latency Timer] section happen only to the last data transfer less than
384 bytes.
USB serial conversion device drivers request USB Transfer Sizes of 4K bytes
at default setting.
When data is transferred from RS-232C to a PC, the USB drivers transfer
data to USB serial conversion device drivers when USB drivers detect the
following event:
Due to structure of Windows OS itself, data transfer is not made real time
from USB60FPW drivers to applications. For example, while rapidly moving
the taskbar of application by the mouse, received data sometimes are lost
when data transfer is made from RS-232C with at a speed of 115.2kbps.
It is strongly recommended that hardware flow control or software flow control is
enabled.
13
4. Specifications
Note:
1. Do not remove while the application is communicating. System will be
unstable.
2. Do not operate to suspend while the application is communicating.
System will be unable to resume properly.
3. This product does not support the serial mouse for connecting to RS-232C
port.
14