NOTFALL

Compact 7
Premium multi-parameter patient monitor

• 10.4" wide TFT color monitor ( 800 x 600 pixels)


• 7 ch. ECG (optional 12ch. ECG), SpO2, 2xIBP, NIBP,
Respiration, 2x Temperature
• Various optional EtCO2 modules (Mainstream, Sidestream)
• 120 hours trend saving time
• Networkable with PC (LAN; RS 232, HL7 and optional WLAN)
Specifications - General Specifications - Performance

Monitor Performance Specification ECG


Display 10,4” Colour TFT-Monitor (800 x 600) Lead type 3 - lead, 5 - lead

Dimension 270 (W) x 250 (H) x 184.5 (D) mm, About 4.0 kg Lead Selection 3 - lead : I, II, III, 5 - lead : I, II, III, aVR, aVL, aVF, V

Up to 6 waves (2*ECG, SpO2, RR or EtCO2, 2*IBP), ECG waveforms 3 - lead : 1 channel, 5-lead : 3 / 7 channels
Categorized alarms (4 priority levels),
Adult : 30 - 300 bpm, Neonate / Pediatric :
Indicators Visual alarm handle lamp, Heart Rate Range
30 - 350 bpm
Heart rate tone, Battery status,
External power LED Heart Rate Accuracy ±1bpm or ±1%, whichever is greater
Tabular Trends Memory Storage: 120 hours Sweep speed 6.25, 12.5, 25, 50 mm / sec
DC input connector: 12 to 18 VDC, 2.5 A, Diagnostic mode : 0.05 Hz-120 Hz, Monitoring
Filter
Defibrillator Sync Output, mode : 0.5-40 Hz, Surgical mode : 0.5-25 Hz
Signal Level: 0 to 5 V pulse,
Interfaces Pulse Width: 100 ±10 ms, S-T segment detection range -2.0 to 2.0 mV
LAN digital output for transferring data, ASYSTOLE, VTACH, VFIB, BIGEMINY, ACCVENT,
Nurse call system connection, Arrhythmia analysis CO U P L E T, I R R E G U L A R , PAU S E , P V C , R O N T,
DC output: 5 VDC, 1A max. TRIGEMINY, VBRADY, SHORTRUN
Pacemaker Detection Mode Indicator on waveform display (user selectable)
Internal battery: rechargeable Li - ion battery,
Battery (standard) Battery status indicator, Against electrosurgical interference and
Protection
Operating time: 2 hours typically defibrillation

Thermal Printer Speeds: 25, 50 mm / sec., Paper Width: 57 mm Respiration


Method Thoracic impedance
EtCO2
Channel selection RA-LA or RA-LL
EtCO2 Respironics®Mainstream / Sidestream
Measurement range 5 - 120 Breath per minute
Measurement range 0~150 mmHg
Accuracy ±1 Breath per minute
0-40 mmHg ±2 mmHg, 41-70 mmHg ±5% of reading
Accuracy 71-100 mmHg ±8% of reading, 101-150 mmHg ±10% Apnea alarm Yes
of reading
SpO2
Respiration rate 2~150 breath per minute
Saturation range 0 to 100 %
Respiration accuracy ±1 breath per minute
Saturation accuracy 70 to 100 % ±2 digits , 0 to 69% unspecified
Accessories | Languages
Pulse rate range 0 to 254 bpm
5-lead patient cable 1ea., NIBP extension tube 1ea.,
Standard Adult NIBP reusable cuff 1ea., SpO2 sensor extension cable Pulse rate accuracy ±2 bpm
Accessory 1ea., Adult SpO2 reusable sensor 1ea.,DC Adapter 18 VDC
NIBP
2.5 A 1ea., Thermal paper 2rolls
Method Oscillometry with linear deflation
Temperature probe (rectal / skin), IBP transducer
Optional Accessory Mainstream / Sidestream EtCO2 module, 3 - lead patient Operation Mode Manual / Automatic / Continuous
cable
Adult Pressure : 20 to 260 mmHg
German, English, French, Spanish, Italian, Russian, Czech, Measurement range Pediatric Pressure : 20 to 230 mmHg
Language Neonate Pressure : 20 to 120 mmHg
Polish, Turkish, Romanian, Portuguese, Bulgarian
mean error : less than ±5 mmHg
Accuracy
Standard Accessories standard deviation : less than 8 mmHg

Temperature
Measurement range 15 to 45 °C (59 to 113 °F)

Accuracy ±1 °C

Compatibility YSI Series 400 temperature probes

IBP
Dimensions Channels 2

Measurement range -50 to 300 mmHg

<100 mmHg : ±1 mmHg, >=100 mmHg : ±1 % of


Accuracy
reading
250 mm
250 mm

Pulse rate measurement range 0 to 300 bpm

Range : ±200 mmHg, Accuracy : ±1 mmHg


Zero balancing
Drift : ±1 mmHg over 24 hours
270 mm 184,5 mm
Transducer sensitivity 5µV / mmHg

0123
Distributor

Im Erlengrund 20, 46149 Oberhausen - Germany

t: +49 (0)208 / 377 890 - 0 [email protected]


f: +49 (0)208 / 377 890 - 55 www.medical-econet.com
facebook.com/medicaleconetgermany
*All specifications are subject to change without notice