FEATURES
• Body material of carbon steel or stainless steel
• 300 series stainless steel float and trim
• Threaded or flanged mounting t62 with threaded
process connection
• Specific gravity ratings down to 0.40
• Process temperatures to +540 °C (+1000° F)
• Field-adjustable level differential
• Choice of switch mechanism:
Dry contact, Hermetically sealed, Pneumatic
• Choice of switch mechanism enclosure:
Weatherproof, Explosion proof, Intrinsically safe
optional:
- NACE construction
- Interface calibration
- Special actuating levels
t62 with flanged
- Code compliance construction process connection
APPLICATIONS
• Day Tanks
• Condensate Receivers
• Fuel Storage Tanks
• Cooling Towers
• Flash Tanks
• Interface
• High and high/high alarm from single tank entry
PRINCIPLE OF OPERATION
Side mounting units employ permanent magnetic force as snap
the only link between the float and the switching element. switch
As the pivoted float follows liquid level changes, it moves a pivot
pivot
float
MOUNTING
t62/t64
in external cage
t62/t64/t67
2
AGENCY APPROVALS
Ce The units are conform to the ATEX directive 2014/34/EU, PED directive
2014/68/EU, Low Voltage Directive 2014/35/EU and RoHS directive 2011/65/EU
Other approvals are available, consult factory for more details
3
SWITCH MECHANISMS AND HOUSINGS
• Series B and C switches are general purpose units • Suited for process industry applications in hazardous
with a selection of maximum liquid temperature ratings locations or where electrical power is not available
• Series D switch is designed for high DC current • Series J bleed type switch is intended for
applications general purpose applications
• Series U switches have gold alloy contacts • Series K switch is specially designed to provide non-
bleed operation with a high degree of vibration resis-
• Series R switches are designed for the highest temper- tance
ature applications up to +540 °C (+1000 °F)
• Ideal for use in salt and other corrosive atmospheres • Stainless steel housings
• Optional housing heaters and drains
available for some housings
• Pneumatic switch mechanisms available with alu
base/cold rolled steel cover
• Electrical switch mechanisms for high temperature
available with aluminium base / cold rolled steel cover
➀
¡
For more details see bulletin BE 42-683
¬
For more details on HS Hermetically sealed switches, see bulletin BE 42-694
√
For more details on J & K Pneumatic switches, see bulletin BE 42-685 and bulletin BE 42-686
For more details on V Inductive Proximity switches, see bulletin BE 42-798
4
SELECTION DATA
float float
L L
➀ Nozzle length is dimension L from end of standard control body to opening in tank having minimum diameter listed for each model.
5
SELECTION DATA T62/T64 SINGLE SWITCH
A complete measuring system consists of:
PROCESS CONNECTION
– threaded
F 2 3" NPT
– ASMe flanges .– en flanges
G 3 3" 150 lbs ASME RF 7 F DN 80, PN 16 EN 1092-1 Type B1
G 4 3" 300 lbs ASME RF 7 G DN 80, PN 25/40 EN 1092-1 Type B1
H 3 4" 150 lbs ASME RF 8 F DN 100, PN 16 EN 1092-1 Type B1
H 4 4" 300 lbs ASME RF 8 G DN 100, PN 25/40 EN 1092-1 Type B1
PROCESS CONNECTION
– ASMe flanges .– en flanges
H 3 4" 150 lbs ASME RF 8 F DN 100, PN 16 EN 1092-1 Type B1
H 4 4" 300 lbs ASME RF 8 G DN 100, PN 25/40 EN 1092-1 Type B1
H 5 4" 600 lbs ASME RF 8 H DN 100, PN 63 EN 1092-1 Type B2
8 J DN 100, PN 100 EN 1092-1 Type B2
6
SELECT ELECTRIC SWITCH MECHANISM & HOUSING
M20x1,5 1" NPT M20x1,5 1" NPT M20x1,5 3/4" NPT M20x1,5 1" NPT 1" NPT M20x1,5 1" NPT M20x1,5 1" NPT M20x1,5 3/4" NPT M20x1,5 1" NPT 1" NPT
Series B
-40 to +120 1x SPDT B2P BAP BHC BAC BK7 BU7 – – BKP B2Q BAQ BH9 BA9 BK5 BU5 – – BKQ
Snap
switch (-40 to +250) 1x DPDT B8P BDP BJC BBC BD7 BW7 – – BNP B8Q BDQ BJ9 BB9 BD5 BW5 – – BNQ
Series C
-40 to +230 1x SPDT C2P CAP CHC CAC CK7 CU7 C2L CAL CKP C2Q CAQ CH9 CA9 CK5 CU5 C2S CAS CKQ
Snap
switch (-40 to +450) 1x DPDT C8P CDP CJC CBC CD7 CW7 C8L CDL CNP C8Q CDQ CJ9 CB9 CD5 CW5 C8S CDS CNQ
Series d
-40 to +120 1x SPDT – – – – – – – – – D2Q DAQ DH9 DA9 DK5 DU5 – – DKQ
DC Current Snap
switch (-40 to +250) 1x DPDT – – – – – – – – – D8Q DDQ DJ9 DB9 DD5 DW5 – – DNQ
Series F
Hermetically -45 to +400 1x SPDT F2P FAP FHC FAC FK7 FU7 – – FKP F2Q FAQ FH9 FA9 FK5 FU5 – – FKQ
sealed (-50 to +750) 1x DPDT F8P FDP FJC FBC FD7 FW7 – – FNP F8Q FDQ FJ9 FB9 FD5 FW5 – – FNQ
Snap switch
Series HS
Hermetically -45 to +290 ¡ 1x SPDT – – – – – – – – – H7A HM2 HFC HA9 HB3 HB4 – – HM3
sealed (-50 to +550) 1x DPDT – – – – – – – – – H7C HM6 HGC HB9 HB7 HB8 – – HM7
Snap switch
Series u
Gold alloy -40 to +120 1x SPDT U2P UAP UHC UAC UK7 UU7 U2L UAL UKP U2Q UAQ UH9 UA9 UK5 UU5 U2S UAS UKQ
contacts (-40 to +250) 1x DPDT U8P UDP UJC UBC UD7 UW7 U8L UDL UNP U8Q UDQ UJ9 UB9 UD5 UW5 U8S UDS UNQ
Snap switch
Series V
-40 to +100
Inductive – – – – – – – VFS VHS – – – – – – – V5S VBS –
Proximity switch (-40 to +210)
Series W
Hermetically 1x SPDT W2P WAP WHC WAC WK7 WU7 W2L WAL WKP W2Q WAQ WH9 WA9 WK5 WU5 W2S WAS WKQ
sealed -45 to +230
Silver plated (-50 to +450)
contacts 1x DPDT – – – – – – – – – W8Q WDQ WJ9 WB9 WD5 WW5 W8S WDS WNQ
Snap switch
Series X
Hermetically 1x SPDT X2P XAP XHC XAC XK7 XU7 X2L XAL XKP X2Q XAQ XH9 XA9 XK5 XU5 X2S XAS XKQ
sealed -45 to +230
Gold plated (-50 to +450)
contacts 1x DPDT – – – – – – – – – X8Q XDQ XJ9 XB9 XD5 XW5 X8S XDS XNQ
Snap switch
Series R
-40 to +400 1x SPDT – – – – – – – – – R2Q R1Q RH9 RA9 RK5 RU5 – – RKQ
High temperature
Snap switch (-40 to +750) 1x DPDT – – – – – – – – – R8Q RDQ RJ9 RB9 RN5 RF5 – – RNQ
Series 8
Hermetically -45 to +400 1x SPDT 82P 8AP 8HC 8AC 8K7 8U7 – – 8KP 82Q 8AQ 8H9 8A9 8K5 8U5 – – 8KQ
sealed (-50 to +750) 1x DPDT 88P 8DP 8JC 8BC 8D7 8W7 – – 8NP 88Q 8DQ 8J9 8B9 8D5 8W5 – – 8NQ
Snap switch
Series 9
High temperature 1x SPDT 92P 9AP 9HC 9AC 9K7 9U7 – – 9KP 92Q 9AQ 9H9 9A9 9K5 9U5 – – 9KQ
-45 to +400
Hermetically
sealed (-50 to +750)
1x DPDT 98P 9DP 9JC 9BC 9D7 9W7 – – 9NP 98Q 9DQ 9J9 9B9 9D5 9W5 – – 9NQ
Snap switch
➀ Process temperature based on max. 40 °C (100 °F) ambient temperature and for non steam applications.
¡ On steam applications, temperature down-rated to +200 °C (+400 °F) process at +40 °C (+100 °F) ambient.
¬ Upon prolonged exposure to temperatures above 425 °C (800 °F), the carbide phase of steel may be converted to graphite. Permissible but not recommend-
ed for prolonged use above 425 °C (800 °F). (Applies to models T62-A & T62-B, T64-A & T64-B.)
7
SELECTION DATA T67 DUAL SWITCH
A complete measuring system consists of:
PROCESS CONNECTION
– threaded
F 2 3" NPT
– ASMe flanges .– en flanges
G 3 3" 150 lbs ASME RF 7 F DN 80, PN 16 EN 1092-1 Type B1
G 4 3" 300 lbs ASME RF 7 G DN 80, PN 25/40 EN 1092-1 Type B1
H 3 4" 150 lbs ASME RF 8 F DN 100, PN 16 EN 1092-1 Type B1
H 4 4" 300 lbs ASME RF 8 G DN 100, PN 25/40 EN 1092-1 Type B1
8
SELECT ELECTRIC SWITCH MECHANISM & HOUSING
M20x1,5 1" NPT M20x1,5 1" NPT M20x1,5 3/4" NPT M20x1,5 1" NPT 1" NPT M20x1,5 1" NPT M20x1,5 1" NPT M20x1,5 3/4" NPT M20x1,5 1" NPT 1" NPT
Series B
-40 to +120 2x SPDT B4A BBA BLC BDC BL7 BV7 – – BLA B4B BBB BL9 BD9 BL5 BV5 – – BLB
Snap
switch (-40 to +250) 2x DPDT B1A BEA BPC BGC BO7 BY7 – – BOA B1B BEB BP9 BG9 BO5 BY5 – – BOB
Series C
-40 to +230 2x SPDT C4A CBA CLC CDC CL7 CV7 C4X CBX CLA C4B CBB CL9 CD9 CL5 CV5 C4T CBT CLB
Snap
switch (-40 to +450) 2x DPDT C1A CEA CPC CGC CO7 CY7 C1X CEX COA C1B CEB CP9 CG9 CO5 CY5 C1T CET COB
Series d
-40 to +120 2x SPDT – – – – – – – – – D4B DBB DL9 DD9 DL5 DV5 – – DLB
DC Current Snap
switch (-40 to +250) 2x DPDT – – – – – – – – – D1B DEB DP9 DG9 DO5 DY5 – – DOB
Series F
Hermetically -45 to +400 2x SPDT FFA FBA FLC FDC FL7 FV7 – – FLA FFB FBB FL9 FD9 FL5 FV5 – – FLB
sealed (-50 to +750) 2x DPDT FHA FEA FPC FGC FO7 FY7 – – FOA FHB FEB FP9 FG9 FO5 FY5 – – FOB
Snap switch
Series u
Gold alloy -40 to +120 2x SPDT U4A UBA ULC UDC UL7 UV7 U4X UBX ULA U4B UBB UL9 UD9 UL5 UV5 U4T UBT ULB
contacts (-40 to +250) 2x DPDT U1A UEA UPC UGC UO7 UY7 U1X UEX UOA U1B UEB UP9 UG9 UO5 UY5 U1T UET UOB
Snap switch
Series W
Hermetically 2x SPDT W4A WBA WLC WDC WL7 WV7 W4X WBX WLA W4B WBB WL9 WD9 WL5 WV5 W4T WBT WLB
sealed -45 to +230
Silver plated (-50 to +450)
contacts 2x DPDT W1B WEB WP9 WG9 WO5 WY5 W1T WET WOB W1B WEB WP9 WG9 WO5 WY5 W1T WET WOB
Snap switch
Series X
Hermetically 2x SPDT X4A XBA XLC XDC XL7 XV7 X4X XBX XLA X4B XBB XL9 XD9 XL5 XV5 X4T XBT XLB
sealed -45 to +230
Gold plated (-50 to +450)
contacts 2x DPDT X1B XEB XP9 XG9 XO5 XY5 X1T XET XOB X1B XEB XP9 XG9 XO5 XY5 X1T XET XOB
Snap switch
Series R
-40 to +400 2x SPDT R4B R3B RL9 RD9 RL5 RV5 – – RLB R4B R3B RL9 RD9 RL5 RV5 – – RLB
High temperature
Snap switch (-40 to +750) 2x DPDT RHB REB RP9 RG9 RO5 RG5 – – ROB RHB REB RP9 RG9 RO5 RG5 – – ROB
Series 8
Hermetically -45 to +400 2x SPDT 84A 8BA 8LC 8DC 8L7 8V7 – – 8LA 84B 8BB 8L9 8D9 8L5 8V5 – – 8LB
sealed (-50 to +750) 2x DPDT 81A 8EA 8PC 8GC 8O7 8Y7 – – 8OA 81B 8EB 8P9 8G9 8O5 8Y5 – – 8OB
Snap switch
Series 9
High temperature 2x SPDT 94A 9BA 9LC 9DC 9L7 9V7 – – 9LA 94B 9BB 9L9 9D9 9L5 9V5 – – 9LB
-45 to +400
Hermetically
sealed (-50 to +750)
2x DPDT 91A 9EA 9PC 9GC 9O7 9Y7 – – 9OA 91B 9EB 9P9 9G9 9O5 9Y5 – – 9OB
Snap switch
ATEX (IP 66) ATEX (IP 66)
Process ➀
Weather proof Weather proof
(IP 65) II 2G Ex d IIC T6 Gb (IP 65) II 2G Ex d IIC T6 Gb
Switch Temperature
Contacts
Description Range CS/Aluminium Cast Iron CS/Aluminium Cast Iron
°C (°F)
3/4" NPT M20x1,5 3/4" NPT 3/4" NPT M20x1,5 3/4" NPT
Series R
High -40 to +540 ¡ 2x SPDT R3M RL5 RV5 R3M RL5 RV5
temperature (-40 to +1000) 2x DPDT REM RO5 RG5 REM RO5 RG5
Snap switch
Series 9
High temperature 2x SPDT 9BD 9L7 9V7 9BM 9L5 9V5
-40 to +540 ¡
Hermetically
sealed (-40 to +1000)
2x DPDT 9ED 9O7 9Y7 9EM 9O5 9Y5
Snap switch
➀ Process temperature based on max. 40 °C (100 °F) ambient temperature and for non steam applications.
¡ Upon prolonged exposure to temperatures above 425 °C (800 °F), the carbide phase of steel may be converted to graphite. Permissible but not recommend-
ed for prolonged use above 425 °C (800 °F). (Applies to models T67-A & T67-B.)
9
PHYSICAL SPECIFICATIONS
description Specification
Measured variable Liquid level / interface level
Physical range Standard models: min S.G. 0,40
Cage and process connection material Carbon steel or stainless steel (others at request)
Float 316 SST (1.4401) – T62/T67; 304 SST (1.4301) – T64
Wetted materials Trim 316 SST (1.4401)
Magnetic sleeve 316 SST (1.4401), or 400 series SST
ELECTRICAL SPECIFICATIONS
description Specification
Up to 15 A @ 240 V AC (depending on switch mechanism)
Switch ratings Up to 10 A @ 120 V DC (depending on switch mechanism)
Signal output Single or dual SPDT or DPDT contacts or single pneumatic
Dry contact with standard or gold alloy contacts, Hermetically sealed, Hermetically sealed
Switch types (see page 4) with gold or silver plated contacts, Proximity switch, or single pneumatic bleed and non bleed
ELECTRICAL CONNECTION
Relay
Power
i.S.
Power
10
DIMENSIONS in mm (inches)
X X
Y
Y
Z V
V
Z
W
W X 78*
(3.07)
78*
(3.07) Y
114 (4.50)
this dimension
Z V 124 (4.88) this dimension
219 (8.62) equals float, equals float,
+ stem length, 229 (9.00) + stem length,
minus 66 minus 76
(2.60) model t62/t67 flanged
model t62/t67 threaded W (3.00)
90*
(3.54)
min level
differential
32 (1.25)
V W øX Y
Housing type Models Z
mm inches mm inches mm inches mm inches
T62/T64 with HS-switch
Weatherproof- 257 10.12 M20 x 1,5 (*) or 1" NPT
and T67
FM (NEMA 7/9) - 42 1.66 151 5.93 109 4.29 (2 entries - 1 plugged)
ATEX (Cast Alu) T62/T64 excl. HS-switch 202 7.94 (*) not for FM (neMA 7/9)
Allow 200 mm (7.87") overhead clearance / All housings are 360 ° rotatable
11
QuALitY ASSuRAnCe - iSo 9001
THE QUALITY ASSURANCE SYSTEM IN PLACE AT MAGNETROL GUARANTEES THE HIGHEST LEVEL OF QUALITY DURING THE DESIGN,
THE CONSTRUCTION AND THE SERVICE OF CONTROLS.
OUR QUALITY ASSURANCE SYSTEM IS APPROVED AND CERTIFIED TO iSo 9001 AND OUR TOTAL COMPANY IS COMMITTED TO PRO-
VIDING FULL CUSTOMER SATISFACTION BOTH IN QUALITY PRODUCTS AND QUALITY SERVICE.
PRoduCt WARRAntY
ALL MAGNETROL MECHANICAL LEVEL CONTROLS ARE WARRANTED FREE OF DEFECTS IN MATERIALS AND WORKMANSHIP FOR 3
FULL YEARS FROM THE DATE OF ORIGINAL FACTORY SHIPMENT.
IF RETURNED WITHIN THE WARRANTY PERIOD; AND, UPON FACTORY INSPECTION OF THE CONTROL, THE CAUSE OF THE CLAIM IS DETERMINED TO BE COVERED
UNDER THE WARRANTY; THEN, MAGNETROL INTERNATIONAL WILL REPAIR OR REPLACE THE CONTROL AT NO COST TO THE PURCHASER (OR OWNER) OTHER THAN
TRANSPORTATION.
MAGNETROL SHALL NOT BE LIABLE FOR MISAPPLICATION, LABOR CLAIMS, DIRECT OR CONSEQUENTIAL DAMAGE OR EXPENSE ARISING FROM THE INSTALLATION
OR USE OF THE EQUIPMENT. THERE ARE NO OTHER WARRANTIES EXPRESSED OR IMPLIED, EXCEPT, SPECIAL WRITTEN WARRANTIES COVERING SOME
MAGNETROL PRODUCTS.
BULLETIN: BE 44-116.14
EFFECTIVE: JULY 2021
SUPERSEDES: October 2019
UNDER RESERVE OF MODIFICATIONS
www.magnetrol.com