mLAB QUIZ
mLAB QUIZ
2. A centrifugal pump delivers 80 liters per second of 4. A Centrifugal pump delivers 300000 liters per hour
water on test suction gauge reads 10 mm Hg of water to a pressurized tank whose pressure is 280
vacuum and 1.2 m below pump centerline. Power kPa. The source of water is 5 meters below the
input is 70 kW. Find the total dynamic head in pump. The diameter of the suction pipe is 300 mm
meters. and the discharge pipe is 250 mm. Calculate the kW
rating of the driving motor assuming the pump
efficiency to be 72%.
5. The rate of flow of water in a pump installation is 7. A boiler feed pump receives 40 L/s at 4 MPa and
60.6 kg/s. The intake static gage is 1.22m below the 180oC. It operates against a total head of 900 m with
pump centerline and reads 68.95 kPa gage; the an efficiency of 60%. Determine the power output of
discharge static gage is 0.61 m below the pump the driving motor.
centerline and reads 344.75 kPa gage. The gages
are located close to the pump as much as possible.
The area of the intake and discharge pipes are 0.093
m2 and 0.069 m2 respectively. The pump efficiency
is 74%. Take density of water equals 1000 kg/m3.
What is the hydraulic power in kW?