GENERAL NOTES FOUNDATIONS

1. THESE STAIR STRUCTURES HAVE BEEN DESIGNED IN ACCORDANCE WITH THE 1. GENERAL
BRITISH COLUMBIA BUILDING CODE 2012, PART 4. a.) DESIGN SOIL BEARING PRESSURE IS 1500 psf.
1a. THE EXISTING STRUCTURE HAS NOT BEEN REVIEWED FOR CONFORMANCE WITH b.) AFTER EXCAVATION AND BEFORE CONSTRUCTING FOUNDATIONS HAVE A
THE BC BUILDING CODE REQUIREMENTS GEOTECHNICAL ENGINEER INSPECT THE FOUNDATIONS AND CONFIRM THE SOIL
2. CONSTRUCT REPAIRS TO BRITISH COLUMBIA BUILDING CODE REQUIREMENTS. BEARING PRESSURE. THE GEOTECHNICAL ENGINEER MAY REQUIRE CHANGES TO
3. DESIGN LOADS (psf) : THE FOUNDATION.
2. PRODUCTS
LEVEL LL
a.) GRANULAR BASE : 3 4" MINUS CLEAN PIT RUN SAND AND GRAVEL WITH LESS THAN
STAIR LIVE LOAD 100 5% PASSING THE # 200 SIEVE.
3. EXECUTION
GROUND SNOW LOAD 42 a.) REMOVE TOPSOIL AND OTHER ORGANIC MATERIAL FROM BUILDING AREA.
b.) EXTEND ALL FOUNDATIONS TO FIRM, UNDISTURBED, NATIVE SOIL, OR TO A
b) SNOW: (KPA) c) WIND: (KPA) MINIMUM 18" BELOW GRADE, OR TO ELEVATIONS SHOWN ON THE DRAWINGS,
Ss = 2.3 Q 110 = 0.36 WHICHEVER IS DEEPER.
Sr = 0.2 Q 150 = 0.47 c.) REMOVE ALL LOOSE MATERIAL FROM FOOTING PRIOR TO POURING CONCRETE.
d) SEISMIC: d.) THE SLAB ON GRADE MAY BE PLACED ON A 6" LAYER OF ROAD MULCH DIRECTLY
Sa (.2) =0.99, Sa (.5) =0.66, Sa (1.0) =0.33, Sa (2.0) =0.17 OR ON THE NATIVE SOIL. BACKFILL OVER EXCAVATED AREAS IN 8" LIFTS OF
PGA = 0.49 GRANULAR BASE COMPACTED TO 98% SPDD.

4. READ STRUCTURAL DRAWINGS IN CONJUNCTION WITH ALL OTHER CONTRACT


DRAWINGS AND DOCUMENTS. ANY DISCREPANCIES MUST BE REPORTED
IMMEDIATELY FOR CLARIFICATION.
5. DO NOT INSTALL OPENINGS, SET INSERTS, DRILL OR ATTACH TO STRUCTURAL
FRAME WITHOUT AUTHORIZATION OF ENGINEER EXCEPT AS NOTED ON DRAWINGS. STRUCTURAL WOOD FRAMING
6. ALL STRUCTURAL ITEMS MUST BE INSPECTED BY THE STRUCTURAL ENGINEER OR
BY ANOTHER SUITABLE QUALIFIED PERSON. 1. GENERAL
7. NOTIFY THE ENGINEER 24 HOURS IN ADVANCE FOR INSPECTION OF THE a.) PROVIDE STRUCTURAL FRAMING AND PERFORM WORK TO 2012 BCBC AND CSA
FOLLOWING: CAN3 086.
a.) REINFORCING STEEL : BEFORE EACH CONCRETE POUR. 2. PRODUCTS
b.) WOOD FRAMING : PLYWOOD WALLS, ROOF, BEFORE COVER UP. a.) LUMBER TO BE NO. 2 OR BETTER S-P-F AND TO CONFORM TO CSA 70, THE
8. CHECK WORK IS COMPLETED BEFORE CALLING FOR INSPECTIONS. NLGA STANDARD GRADING RULES FOR CANADIAN LUMBER, AND TO HAVE A
9. BRACE THE STRUCTURE UNTIL ALL THE COMPONENTS ARE PERMANENTLY FASTENED MAXIMUM OF 19% MOISTURE CONTENT AT THE TIME OF INSTALLATION. EXISTING ARENA
IN PLACE. BRACING SHOWN IS FOR COMPLETED STRUCTURE ONLY. b.) PLYWOOD : DOUGLAS FIR SHEATHING GRADE TO CSA 0121. EXTERIOR GRADE
10. VERIFY ALL DIMENSIONS PRIOR TO CONSTRUCTION .FAILURE TO DO SO SHALL FOR WALLS WALLS AND ROOF. TONGUE AND GROOVE FOR FLOORS. SUBSTITUTION SEE DWG S-4 BUILDING
RENDER THE CONTRACTOR RESPONSIBLE TO REPAIR ANY IMPROPER WORK. WITH OSB IS NOT PERMITTED. ST
11. METRIC AND IMPERIAL UNITS USED INTERCHANGEABLY. c.) BOLTS : TO ASTM STANDARD A307. AIR
12. ONLY STRUCTURAL COMPONENTS DETAILED ON OUR DRAWINGS HAVE BEEN d.) JOIST AND BEAM HANGERS, METAL FASTENERS, AND FRAMING ANCHORS:
DESIGNED BY US. OTHER STRUCTURAL COMPONENTS AND ANY OTHER BUILDING PROPERLY TESTED IN ACCORDANCE WITH ICBO CRITERIA AND ANALYZED TO #3
COMPONENTS ARE THE RESPONSIBILITY OF THEIR RESPECTIVE DESIGNERS. THIS EVALUATE LOAD CAPACITIES.
(N
INCLUDES, BUT IS NOT LIMITED TO, DAMP PROOFING AND WATER PROOFING
SYSTEMS.
e.) LUMBER GRADE : # 2 DOUGLAS FIR FOR ALL MEMBERS DETAILED ON
STRUCTURAL DRAWINGS INCLUDING JOISTS, PLATES, STUDS, LEDGERS, AND
W)
13. THESE DESIGN DOCUMENTS ARE PREPARED SOLELY FOR THE USE BY THE PARTY BLOCKING. #1 FOR COLUMNS.
WITH WHOM THE PROFESSIONAL HAS ENTERED INTO A WRITTEN CONTRACT AND f.) NO ACQ-D, CA-B, AND SBX PRESSURE TREATED PRESERVATIVE IS PERMITTED.
THERE ARE NO REPRESENTATIONS OF ANY WHOM THE PROFESSIONAL HAS NOT g.) THE USE OF FINGER-JOINTED STUDS IS PERMITTED ONLY FOR INTERIOR
ENTERED INTO SUCH A CONTRACT. NON-SHEAR WALLS. THE GRADING OF THE FINGER-JOINTED STUDS MUST COMPLY
14. DO NOT BUILD FROM THESE DRAWINGS UNLESS THEY ARE MARKED "ISSUED FOR WITH THE GRADING SPECIFIED BY THE NLGA STANDARDS. DO NOT USE
CONSTRUCTION". FINGER-JOINTED LUMBER FOR EXTERIOR WALLS, SHEAR WALLS, FOR ANY TOP OR
15. DESIGN ALL GUARDRAILS, AND HANDRAILS, TO THE REQUIREMENTS OF THE B.C. BOTTOM PLATES, DRAGSTRUTS, AT STUDS W/ HOLD-DOWN STRAPS (SUCH AS THE
BUILDING CODE. END OF SHEARWALLS)
16. USE THE LATEST EDITION OF STANDARDS REFERRED TO IN THESE DOCUMENTS. CONTRACTOR IS TO SUBMIT LIST OF PROPOSED LUMBER SPECIES AND GRADE TO
17. ALL FORMING, SHORING, AND SITE SAFETY ISSUES ARE THE SOLE THE ENGINEER PRIOR TO START OF CONSTRUCTION
RESPONSIBILITY OF THE CONTRACTOR. ANY LUMBER NOT GRADE MARKED WILL BE REJECTED
18. ANY CHANGES TO THE FRAMING SHOWN ON THE DRAWINGS SHALL HAVE PRIOR 3. EXECUTION
WRITTEN APPROVAL OF THE ENGINEER. FRAMING CHANGES THAT HAVE NOT BEEN a.) ERECT FRAMING TO BCBC PART 9, SECTION 23, "WOOD FRAME CONSTRUCTION",
APPROVED WILL BE REJECTED EXCEPT AS NOTED.
19. THE CONTRACTOR IS RESPONSIBLE FOR ALL COSTS ASSOCIATED WITH THE b.) DO NOT OVERDRIVE NAILS FOR PLYWOOD SHEATHING. NAILS WHICH ARE
CORRECTION OF DEFICIENCIES AS DETERMINED BY THE ENGINEER. RECESSED MORE THAN 10% OF THE SHEATHING THICKNESS WILL BE REJECTED.

CONCRETE NOTE:
- ALL POSTS, COLUMNS, BEAMS, STRINGERS, AND JOISTS TO BE PRESSURE
1. GENERAL TREATED, TYP
a.) PROVIDE CONCRETE AND PERFORM WORK TO CSA CANS-A23.1.
b.) RETAIN A CONCRETE TESTING AGENCY APPROVED BY THE ENGINEER TO TEST
AGGREGATES, DESIGN MIX AND TAKE, AND TEST CONCRETE CYLINDERS TO
CSA-A23.1 AND CSA-A23.2. SUBMIT REPORTS TO ENGINEER.
2. PRODUCTS SEE DWG S-3
a.) CEMENT : TYPE "10 PORTLAND CEMENT".
b.) REINFORCING STEEL : NEW DEFORMED BARS TO CSA G30.18 GRADE 400.
WELDED WIRE FABRIC TO CSA G30.5.
c.) AGGREGATE AND WATER : TO CSA CAN3-A23.1.
d.) ADMIXTURES : AIR ENTRAINING TO CSA A266.1. WATER REDUCING TO ASTM ST
C494-TYPE A. AIR
e.) ANCHOR BOLTS : TO ASTM A307.
f.) FORMWORK : SMOOTH, SQUARE EDGED PLYWOOD PANELS. #2
g.) MIX DESIGN: 28 DAY MAXIMUM EXPOSURE
(N
DESCRIPTION
FOOTING
STRENGTH (MPa) AGGREGATE
25 3
4"
CLASS
F2
W)
3
SLABS/GRADE 32 4" C2

3. EXECUTION
a.) MIX AND PLACE CONCRETE TO CSA CAN3 A23.1. SEE DWG S-2
b.) VERTICAL DROP OF CONCRETE NOT TO EXCEED 5'-0".
c.) COMPACT CONCRETE WITH INTERNAL TYPE MECHANICAL VIBRATORS. WORK
CONCRETE AROUND ALL EMBEDDED MATERIAL AND INTO CORNERS OF FORMS. STAIRS SITE PLAN
d.) UNLESS NOTED OTHERWISE PROVIDE CLEAR CONCRETE COVER OVER REBAR AS SCALE : 1/8"=1'-0"
FOLLOWS :
SURFACES POURED AGAINST GROUND 3"
FORMED SURFACES EXPOSED TO GROUND OR WEATHER 2" ST
OTHER FORMED SURFACES : SLABS, WALLS
BEAMS AND COLUMNS
1"
112"
AIR
e.) REINFORCING DETAILS SHALL CONFORM TO ACI 315-80 OR AS NOTED ON
DRAWINGS. COLUMNS, PILASTERS, AND PEDESTALS TO HAVE TIES HOOKED 135
#1
DEGREES OR AS DETAILED ON DRAWINGS.
NOTE: CONTRACTOR TO
(S
f.) EMBEDDED MATERIAL SHALL BE FREE FROM GREASE, SCALE, AND OTHER
REMOVE ALL EXISTING
FOOTINGS, STAIRS AND W)
COATINGS. PLACE REBAR IN ACCORDANCE WITH CSA CAN3-A23.1 AND SECURE HANDRAILS
WITH CLIPS OR WIRE NOT LESS THAN 16 GAUGE.
g.) CONTINUE WALL STEEL AROUND CORNERS.
h.) MINIMUM SPLICE LENGTH, UNLESS NOTED OTHERWISE :
BAR SIZE 10M 15M 20M 25M 30M 35M
LAP (IN) 14" 20" 28" 48" 64" 92"
LAP WELDED WIRE FABRIC 8"
j.) MINIMUM REINFORCING AROUND OPENINGS LARGER THAN 12" : 2-15M EACH
SIDE OF OPENINGS EXTENDED 2'-0" PAST CORNERS. 1-10Mx4'-0" LONG DIAGONAL
AT EACH CORNER. 2-15M AT WALL ENDS.
k.) CONTROL JOINTS : SLAB ON GRADE - 1" DEEP PREFORMED OR SAWCUT
CONCRETE PLACEMENTS AFTER CONCRETE HAS HARDENED SUFFICIENTLY. WALLS -
114" DEEP VEE EACH SIDE OF WALL AT 50'-0" MAXIMUM.
m.) CONSTRUCTION JOINTS : LOCATE KEYED CONSTRUCTION JOINTS AS APPROVED
BY ENGINEER UNLESS DETAILED ON DRAWINGS.
n.) SUPPORT CONCRETE UNTIL IT HAS HARDENED SUFFICIENTLY TO CARRY LOADS.
p.) FORM ACCURACY TOLERANCE 14" IN PLAN AND ELEVATION. SLAB FORM
TOLERANCE 14" IN ELEVATION.
q.) PROVIDE 3 4" CHAMFER TO ALL EXPOSED CORNERS. HAND TOOL EDGES OF SLAB
AND CURBS.
r.) CHAMFER SLABS AND BEAMS AS NOTED OR 14" PER 3'-0" MINIMUM BY SETTING
FORMS AND SCREEDS. JACKING FORMS AFTER CONCRETE IS POURED IS NOT
PERMITTED.
s.) TIE ALL DOWELS AND ANCHOR BOLTS BEFORE POURING CONCRETE.
t.) CURE AND PROTECT IN ACCORDANCE WITH A23.1. CURING COMPOUNDS NOT
ACCEPTABLE WHERE FUTURE TOPPING OR ADHESIVES TO BE APPLIED.
ABBREVIATIONS: J1
dp
JOIST TYPE
DEEP
D.P. DROPPED
u.) OPENINGS, PIPE SLEEVES, ETC. ARE NOT PERMITTED IN STRUCTURAL CONCRETE SF1 STRIP FOOTING TYPE U.N.O. UNLESS NOTED OTHERWISE
UNLESS APPROVED BY ENGINEER. S.F. STEP FOOTING E/W. EACH WAY
FTG. FOOTING E/F. EACH FACE
BOTT. BOTTOM E.F.S. EACH FACE STAGGERED
c/w COMPLETE WITH
DIMENSIONS VERT. VERTICAL BEW
EQUALLY
BOTTOM EACH WAY
HORIZ. HORIZONTAL CONT. CONTINUOUS
- ALL BUILDING DIMENSIONS (EXISTING OR NEW) NOT SHOWN ON OUR DRAWINGS, ALT. ALTERNATE CANT. CANTILEVERED
ARE NOT REQUIRED BY US AND ARE THE RESPONSIBILITY OF THE TYP. TYPICAL 15M@7'-0" DENOTES 15M BARS, 7'-0"
ARCHITECT/CONTRACTOR TO OBTAIN. DO NOTE SCALE DRAWINGS B.O. BLOCK OUT LONG
- TRUSS OR JOIST MANUFACTURE TO FIELD VERIFY ALL DIMENSIONS AND EXISTING TO C1 COLUMN TYPE G.T. GIRDER TRUSS
NEW CONNECTIONS B1 BEAM TYPE P.A. POST ABOVE
7 DESIGNED PROJECT JOB NUMBER

6
SIEFKEN ENGINEERING LTD. LE QUEEN'S PARK ARENA-STAIR REPLACEMENT 2016-327
CONSULTING STRUCTURAL ENGINEERS
5 DRAWN
#203-668 CARNARVON ST. 220-238 FIRST STREET SCALE
4 NEW WESTMINSTER, B.C. V3M 5Y6 NS
3 TEL: (604) 525-4122 FAX: (604) 525-3557 CHECKED
NEW WESTMINSTER, B.C. AS NOTED
E-MAIL.: [email protected]
2 ISSUED FOR TENDER OCT. 3, 2016
COPYRIGHT RESERVED
GS TITLE SHEET NUMBER

1 ISSUED FOR BUILDING PERMIT SEPT 23, 2016 This plan and design are, and at all times remain the
exclusive property of the Engineer and cannot be used or
SEAL
APPROVED
GENERAL NOTES /SITE PLANS S-1 2
REV. DESCRIPTION DATE reproduced without written consent. Do not scale drawing. JRS
C2

C2
B1

2X6 BRACE B
6 6 SEE SECTION
S-5 S-5
PLAN VIEW
SCALE : 1/2"=1'-0"

P1

P1
EL: TO MATCH
1'-7"

1'-10"

SI 1
F1

SI 1
2'-33 4"

F1

F1

F
F
EXISTING

M
P1 P1

P1
BEAM SEE PLAN
1'-10"

8'-914"
BRACE A SEE

6'-612"
8'-0"

SECTION BR 6
AC 2x

C1

C1
E CE
B2 2x A
6 BR

F1

F1
F1

F1
F1
NEW 6" CONC
P1 P1 PLAN VIEW

P1
SLAB ON GRADE
P1

P1
R/w 10M@12"

COL SEE PLAN

COL SEE PLAN


o/c E/W, RAISED SCALE : 1/2"=1'-0"
TO MID HT OF
SLAB. EL: TO MATCH
F1-2'-0"x2'-0"x8" EXISTING
R/w 4-15M E/W FULLY BLOCKED
2'-0" 5'-7" 4'-1" 5'-8" 5'-4" 8'-7"
BOT c/w 4-312" NAILS
BEAM SEE PLAN

2'-6"
2x 4-312" NAILS, TYP
A CE 6
BR
BR

COL SEE PLAN

COL SEE PLAN


A
STAIR #1 (SW) FOUNDATION PLAN NOTE: CONTRACTOR
FIELD CONFIRM ALL
2x
6 CE

SCALE : 3/8"=1'-0" DIMENSIONS, TYPICAL 3-312" NAILS, TYP

2'-6"
EACH END

REUSE +
GUARDRAIL TO
MATCH EXISTING, REPLACE EXISTING B
TYP STEEL BRACKET -

A A A

C2
C2
- - - SIM
EXISTING PIPE
7 DENOTES 2x6 BR-A SECTION BR-B SECTION
S-5 BRACE TYP. A B
C1

C1

C1

SCALE: 1/2"=1'-0" SCALE: 1/2"=1'-0"

GUARDRAIL SEE
3"

DETAIL 4/S-5
2x8 @12"

8'-914"
2x8 @12"
1A
S-5 TYP
BR-A

BR-A

BR-A

BR-B
B1

B1
7'-0"

B2

B2

B2

7'-4" 4'-1" 11'-0"

3'-6"
8 TREADS @ 11" 11 TREADS @ 11"

1
MITRE CORNER, S-5

C2
TYP
C2

LANDING
C1

C1

C1

BR-C
C
1 -
2x12 STRINGER, R/w SIMPSON SIMPSON
2x6, TYP.(4 THUS) S-5 TYP as per BCBC GAP ECC78 ECC78
NOT TO EXCEED
REUSED AND 100mm, TYP

13 RISERS @7.03"
REINSTALL EXISTING 1 BRACE C
HANDRAIL,TYP. SEE 2 BR-A
STAIR #1 (SW) FRAMING PLAN DETAIL 4/S-5 TYP. 2x6

SCALE : 3/8"=1'-0"

7'-7716"
3'-0"
CUT SHIM TO
SUIT
3-312" NAILS, TYP
EACH END
SIMPSON

12'-1012"
ECC COL CAP TO
SUIT BLOCKED,
TYP
LANDING

BR-B
BR-A

SIMPSON
2

9 RISERS @7.03"
ECC COL CAP TO
SUIT S-5

5'-3116"
1
NON-SLIP/HIGH VIS S-5 SIM
YELLOW STRAP, NOT
BR-A BR-A
TO PROJECT MORE
THAN 1MM ABOVE
5 NEW PILASTER
SURFACES, TYP @ S-5 TYP SEE PLAN, TYP
NOTE: FOOTING & PEDESTAL SCHEDULE RUN
FOOTING PEDESTAL
6"

RISE AND RUN TO MEET BC BUILDING


CODE, TYP MARK SIZE REINF. MARK SIZE REINF.

BEAM SCHEDULE 4-15M VERT


3
F1 2'-0"X2'-0"X8"dp. 4-15M E/W P1 12"X12" 10M TIES @10" STAIR #1 (SW) CROSS SECTION
MARK SIZE S-5 C SCALE: 1/2"=1'-0"
B1 4-2X10 FOUNDATION NOTES
B2 4-2X8
- ALL DIMENSIONS ARE TO CONFORM TO THOSE ON THE ARCHITECTURAL DRAWINGS. VERIFY ALL
DIMENSIONS. DO NOT SCALE DRAWINGS.
NOTE:
COLUMN SCHEDULE - 1'-6" MINIMUM FROST COVER TO U/S OF FOOTING.
CONTRACTOR TO SUBMIT NON-SLIP
- ALL REINFORCING TO BE PLACED AT 3" CLEAR FROM BOTTOM OF FOOTING UNLESS NOTED
MARK SIZE OTHERWISE. CHAIR ALL REINFORCING. NOSING / HIGH VISIBILITY YELLOW STRIP
- ALL POSTS TO BE CENTERED ON PAD FOOTINGS TO ENGINEER FOR APPROVAL
C1 6X6
- FOR ALL SLAB SLOPES AND LOCATIONS SEE ARCH DRAWINGS
C2 6X8
7 DESIGNED PROJECT JOB NUMBER

6
SIEFKEN ENGINEERING LTD. LE QUEEN'S PARK ARENA-STAIR REPLACEMENT 2016-327
CONSULTING STRUCTURAL ENGINEERS
5 DRAWN
#203-668 CARNARVON ST. 220-238 FIRST STREET SCALE
4 NEW WESTMINSTER, B.C. V3M 5Y6 NS
3 TEL: (604) 525-4122 FAX: (604) 525-3557 CHECKED
NEW WESTMINSTER, B.C. AS NOTED
E-MAIL.: [email protected]
2 ISSUED FOR TENDER OCT. 3, 2016
COPYRIGHT RESERVED
GS TITLE SHEET NUMBER

1 ISSUED FOR BUILDING PERMIT SEPT 23, 2016 This plan and design are, and at all times remain the
exclusive property of the Engineer and cannot be used or
SEAL
APPROVED
STAIR #1 (SW) PLANS, SECTIONS S-2 2
REV. DESCRIPTION DATE reproduced without written consent. Do not scale drawing. JRS
EXISTING DOOR EXISTING

C2

C2
BUILDING
B1

1'-7"
F1 F1

F1
2X6 BRACE B
P1 SEE SECTION

P1
P1
P1
PLAN VIEW
SCALE : 1/2"=1'-0"
F1 NEW 6" CONC
SLAB ON GRADE
8'-914"

R/w 10M@12" EL: TO MATCH


o/c E/W, RAISED EXISTING
TO MID HEIGHT

6'-612"
BEAM SEE PLAN

8'-0"
EXISTING CONC REUSE EXISTING OF SLAB
STAIR CONC PILASTER BEAM SEE PLAN
NEW 12" PLATE TO

F1
F1

A325 BOLT

F1

F1
P1

P1

P1

P1
P1
BR 6
AC 2x
C BLOCKING /SHIM
AS REQUIRED BRACE A SEE E
2x ACE
- SECTION 6 BR
F1-2'-0"x2'-0"x8"

C1

C1
R/w 4-15M E/W NEW 12"PLATE TO
MATCH LENGTH FULLY BLOCKED
BOT SEE
OF EXISTING B2 c/w 4-312" NAILS
STEEL SEAT
PLAN VIEW

COL SEE PLAN

COL SEE PLAN


11'-4" 5'-8" 5'-10" 3'-7" 6'-6" 2'-0"
EXISTING STEEL SCALE : 1/2"=1'-0"
SEAT EL: TO MATCH
EXISTING

112"
BEAM SEE PLAN
NEW W8x10xLENGTH
TO MATCH EXISTING
STAIR #2 (MIDDLE) FOUNDATION PLAN 4-312" NAILS, TYP

2'-6"
NOTE: CONTRACTOR CHANNEL
FIELD CONFIRM ALL
SCALE : 3/8"=1'-0" 2x
DIMENSIONS, TYPICAL CE 6

6"
A BR
BR

COL SEE PLAN

COL SEE PLAN


6 A CE
2x
GUARDRAIL TO 9"x9"x3 4" THK PL
MATCH EXISTING, c/w 4-3 4 3-312" NAILS, TYP

2'-6"
CHANNEL WALL
MOUNT, TYP
SHIM UNDER
BEAM 7 CHANNEL WALL
MOUNT, TYP
TYP A325 BOLTS c/w HILTI EACH END

112"
HY-200
S-5
EXISTING
BUILDING
D BEAM D A 2x12 STRINGER, R/w
A
- CONTINOUS - - - 112" 6" 112"
SIM 2x6, TYP.(4 THUS)
OVER TOP OF
3"

NEW POST

C1
C2

C1

C1
DENOTES 2x6 WALL SEAT ASSEMBLY NOTE: REPLACE EXISTING BR-A SECTION BR-B SECTION
BRACE, TYP. D SCALE: 3"=1'-0"
BOLTS TO CHANNEL TO
MATCH ORIGINAL
A SCALE: 1/2"=1'-0" B SCALE: 1/2"=1'-0"
B1

2x8 @12" GUARDRAIL SEE


DETAIL 4/S-5
6'-612"
BR-B

B1

B2

B2
BR-A

BR-A
B2

2x8 @12"
11'-0" 4'-1" 7'-4"
MITRE CORNER,
TYP
1A 12 TREADS @ 11" 8 TREADS @ 11"
S-5 TYP
C2

MIN.
3'-6"
C2

C1

C1

C1
BR-C
1
C S-5
- DENOTES 2x6 AS PER BCBC
BRACE, TYP. 1 LANDING
GAP NOT TO
S-5 TYP EXCEED 100mm,
TYP
B
- STAIR #2 (MIDDLE) FRAMING PLAN
SCALE : 3/8"=1'-0"
SIMPSON SIMPSON REUSED AND

13 RISERS @7.03"
ECC78 ECC78 REINSTALL EXISTING
BRACE C
2x6 HANDRAIL,TYP. SEE
DETAIL 4/S-5

3'-0"
BR-A

7'-7716"
1
2
TYP.
CUT SHIM TO
SUIT

SIMPSON
3-312" NAILS, TYP
EACH END ECC COL CAP TO
12'-1012"

SUIT

BLOCKED,
TYP
LANDING

BR-B
2
BR-A S-5
9 RISERS @7.03"

MIRR SIMPSON
ECC COL CAP TO
5'-3116"

SUIT
NON-SLIP/HIGH VIS
1 YELLOW STRAP, NOT
5 BR-A S-5 SIM TO PROJECT MORE
THAN 1MM ABOVE
S-5 TYP SURFACES, TYP @
NEW PILASTER BR-A RUN
NOTE: FOOTING & PEDESTAL SCHEDULE SEE PLAN, TYP

RISE AND RUN TO MEET BC BUILDING FOOTING PEDESTAL

6"
CODE, TYP
MARK SIZE REINF. MARK SIZE REINF.

BEAM SCHEDULE F1 2'-0"X2'-0"X8"dp. 4-15M E/W P1 12"X12"


4-15M VERT
10M TIES @10"
MARK SIZE
B1 4-2X10 FOUNDATION NOTES STAIR #2 (MIDDLE) (SW) CROSS SECTION 3
B2 4-2X8
C SCALE: 1/2"=1'-0"
S-5
- ALL DIMENSIONS ARE TO CONFORM TO THOSE ON THE ARCHITECTURAL DRAWINGS. VERIFY ALL
DIMENSIONS. DO NOT SCALE DRAWINGS.
COLUMN SCHEDULE - 1'-6" MINIMUM FROST COVER TO U/S OF FOOTING. NOTE:
- ALL REINFORCING TO BE PLACED AT 3" CLEAR FROM BOTTOM OF FOOTING UNLESS NOTED
MARK SIZE OTHERWISE. CHAIR ALL REINFORCING.
- ALL POSTS TO BE CENTERED ON PAD FOOTINGS CONTRACTOR TO SUBMIT NON-SLIP
C1 6X6 NOSING / HIGH VISIBILITY YELLOW STRIP
- FOR ALL SLAB SLOPES AND LOCATIONS SEE ARCH DRAWINGS
TO ENGINEER FOR APPROVAL
C2 6X8
7 DESIGNED PROJECT JOB NUMBER

6
SIEFKEN ENGINEERING LTD. LE QUEEN'S PARK ARENA-STAIR REPLACEMENT 2016-327
CONSULTING STRUCTURAL ENGINEERS
5 DRAWN
#203-668 CARNARVON ST. 220-238 FIRST STREET SCALE
4 NEW WESTMINSTER, B.C. V3M 5Y6 NS
3 TEL: (604) 525-4122 FAX: (604) 525-3557 CHECKED
NEW WESTMINSTER, B.C. AS NOTED
E-MAIL.: [email protected]
2 ISSUED FOR TENDER OCT. 3, 2016
COPYRIGHT RESERVED
GS TITLE SHEET NUMBER

1 ISSUED FOR BUILDING PERMIT SEPT 23, 2016 This plan and design are, and at all times remain the
exclusive property of the Engineer and cannot be used or
SEAL
APPROVED
STAIR #2 (MIDDLE) PLANS, SECTIONS AND DETAILS S-3 2
REV. DESCRIPTION DATE reproduced without written consent. Do not scale drawing. JRS
C2

C2
B1

EXISTING 2X6 BRACE B


DOOR, TYP.
BUILDING SEE SECTION
PLAN VIEW
SCALE : 1/2"=1'-0"

2'-43 4"
F1

F1

F1

F1
P1
P1

P1

P1
EL: TO MATCH
EXISTING

NEW 6" CONC BEAM SEE PLAN


SLAB ON GRADE
R/w 10M@12"
o/c E/W, RAISED
TO MID HEIGHT

6'-412"
6'-914"
OF SLAB

BRACE A SEE
SECTION BR 6
AC 2x

C1

C1
F1 E CE

F1
F1

F1
2x A
B2
6 BR

P1

P1
P1
P1
FULLY BLOCKED
c/w 4-312" NAILS
PLAN VIEW
C

COL SEE PLAN

COL SEE PLAN


SCALE : 1/2"=1'-0"
-
2'-0" 4'-6" 4'-8" 8'-3" 8'-10" EL: TO MATCH
F1-2'-0"x2'-0"x8"
R/w 4-15M E/W EXISTING
BOT SEE
NOTE: CONTRACTOR BEAM SEE PLAN
STAIR #3 (NW) FRAMING PLAN FIELD CONFIRM ALL
DIMENSIONS, TYPICAL
4-312" NAILS, TYP

2'-6"
SCALE : 3/8"=1'-0"
GUARDRAIL TO REUSE + 2x
MATCH EXISTING, REPLACE EXISTING A CE 6
BR
BR

COL SEE PLAN

COL SEE PLAN


TYP 6 AC
DOOR, TYP. STEEL BRACKET 2x E

3-312" NAILS, TYP

2'-6"
A A 4-2x12
7
EACH END
- - STRINGER, TYP.
S-5

C2

C2
C1

C1

2x8 @12"
2x8 @12"
1A

BR-B
BR-A SECTION BR-B SECTION

B1
S-5 TYP A B
BR-A

BR-A
BR-A

SCALE: 1/2"=1'-0" SCALE: 1/2"=1'-0"


B2

B2

B1
6'-5" 4'-8" 8'-3" GUARDRAIL SEE
DETAIL 4/S-5
C2

C2
7 TREADS @ 11" 9 TREADS @ 11"
C1

C1

BR-C

C
- 1
S-5 TYP B

3'-6"
min.
MITRE CORNER, -
TYP
1
S-5
LANDING
GAP NOT TO
REUSED AND
STAIR #3 (NW) FRAMING PLAN REINSTALL EXISTING
EXCEED 100mm,
TYP
SCALE : 3/8"=1'-0" HANDRAIL,TYP. SEE SIMPSON SIMPSON
DETAIL 4/S-5 ECC78 ECC78
1
2

10 RISERS @7.03"
TYP.
BRACE C

5'-10516"
2x6

3'-0"
BLOCKED,

10'-8116"
TYP
3-312"
NAILS, TYP
LANDING EACH END
BR-A

8 RISERS @7.03"
SIMPSON
2

4'-93 4"
NON-SLIP/HIGH VIS ECC COL CAP TO S-5
YELLOW STRAP, NOT SUIT BR-B
TO PROJECT MORE
THAN 1MM ABOVE 1 SIM
5
SURFACES, TYP @ BR-A S-5 BR-A S-5 TYP
NEW PILASTER
RUN
SEE PLAN, TYP
6"

NOTE: FOOTING & PEDESTAL SCHEDULE


RISE AND RUN TO MEET BC BUILDING FOOTING PEDESTAL
CODE, TYP
MARK SIZE REINF. MARK SIZE REINF. 3
S-5
BEAM SCHEDULE F1 2'-0"X2'-0"X8"dp. 4-15M E/W P1 12"X12"
4-15M VERT
STAIR #3 (NW) CROSS SECTION
MARK SIZE
10M TIES @10"
C SCALE: 1/2"=1'-0"
B1 4-2X10 FOUNDATION NOTES
B2 4-2X8
- ALL DIMENSIONS ARE TO CONFORM TO THOSE ON THE ARCHITECTURAL DRAWINGS. VERIFY ALL NOTE:
DIMENSIONS. DO NOT SCALE DRAWINGS.
COLUMN SCHEDULE - 1'-6" MINIMUM FROST COVER TO U/S OF FOOTING. CONTRACTOR TO SUBMIT NON-SLIP
- ALL REINFORCING TO BE PLACED AT 3" CLEAR FROM BOTTOM OF FOOTING UNLESS NOTED NOSING / HIGH VISIBILITY YELLOW STRIP
MARK SIZE OTHERWISE. CHAIR ALL REINFORCING. TO ENGINEER FOR APPROVAL
C1 6X6 - ALL POSTS TO BE CENTERED ON PAD FOOTINGS
- FOR ALL SLAB SLOPES AND LOCATIONS SEE ARCH DRAWINGS
C2 6X8
7 DESIGNED PROJECT JOB NUMBER

6
SIEFKEN ENGINEERING LTD. LE QUEEN'S PARK ARENA-STAIR REPLACEMENT 2016-327
CONSULTING STRUCTURAL ENGINEERS
5 DRAWN
#203-668 CARNARVON ST. 220-238 FIRST STREEL SCALE
4 NEW WESTMINSTER, B.C. V3M 5Y6 NS
3 TEL: (604) 525-4122 FAX: (604) 525-3557 CHECKED
NEW WESTMINSTER, B.C. AS NOTED
E-MAIL.: [email protected]
2 ISSUED FOR TENDER OCT. 3, 2016
COPYRIGHT RESERVED
GS TITLE SHEET NUMBER

1 ISSUED FOR BUILDING PERMIT SEPT 21, 2016 This plan and design are, and at all times remain the
exclusive property of the Engineer and cannot be used or
SEAL
APPROVED
STAIR #3 (NW) PLANS, SECTIONS AND DETAILS S-4 2
REV. DESCRIPTION DATE reproduced without written consent. Do not scale drawing. JRS
2x6 CAP
STAIR TREAD: SEE DETAIL 2x6 CONT.
2x6 & 2x8 CUT
TO FIT
STAIR TREAD:
2x6 & 2x8 CUT 1A
TO FIT - SEE DETAIL
, TYP
B 2x4
1 "
2 PLYWOOD 1 "PLYWOOD
- STIFFENER
RISER 2

HEIGHT TO MATCH EXISTING


RISER
11" MIN. RUN
CONTRACTOR TO REUSE
AS PER BCBC REQ'D EXISTING STEEL HANDRAIL, TYP

3'-6" MIN.
2x3 BALUSTERS SEE c/w NEW SCREWS TO MATCH
2-3" NAILS @12"
1.5"MAX CROSS SECTION EXISTING
o.c., TYP
SEE DETAIL 3"x3"x 14"x4" LG. RAKE BACK

4.92"MIN-7" MAX RISERS


ATTACH w/6-212"
1A NAILS TOTAL, 2x6/2x8 SANDBLAST CLEAN 1 COAT

PER BCBC REQ'D


TYP NEW 2x12 STAIR TREADS OR PRIMER AND 2 COATS BLACK
- STRINGERS R/w FINISH PAINT
DECK
JOISTS SEE PLAN 2x6, TYP SEE DETAIL
STAIR TREAD: (NOTE: LINE UP
2x6 & 2x8 CUT TO FIT 5/-, TYP
JOISTS WITH 2x12
GLUED + SCREWED STRINGERS), TYP STRINGERS
ADD ASPHALT NEW
BEAM, SEE PLAN RAMP (TO MATCH R/w 2x6
1 " PILASTER
2 PLYWOOD TOP OF EXISTING
2x6 DECKING
RISER c/w 2-3" FOOTING)

2"
NAILS EACH SIMPSON BRACKET SEE
STRINGER CROSS SECTION HANDRAIL/GUARDRAIL SECTION
BEAM, SEE PLAN B

2"
EXIST. GRADE 2-5 8 SCALE: 3"=1'-0"
POST, SEE PLAN
POST, SEE PLAN 3"X3"X14"X4" LG. c/w WASHERS
NEW 2x12 STAIR NEW 6" SLAB ON ATTACH TO CONC. FTG.
STRINGERS R/w GRADE
2x6, TYP TYP. EACH STRINGER

CONNECTION TO THE TOP OF FLIGHT CONNECTION AT THE BOTTOM OF FLIGHT STAIR BASE DETAIL HANDRAIL/GUARDRAIL SECTION
1 SCALE: 1"=1'-0" 2 SCALE: 1"=1'-0" 3 SCALE: 1"=1'-0" 4 SCALE: 1"=1'-0"

SIMPSON L7 STAIR 212" NAILS @4"


CLIP EACH SIDE EXISTING BLDG EXISTING BLDG
EACH STRINGER, TYP NEW 6X6 POST NEW DECKING
SIMPSON BRACKET
CBGT68 OR 5
CBGT66 TO SUIT 8
SEE PLAN c/w WASHER c/w HILTY
HY EPOXY

3"
(NOTE: LINE UP NEW GALVANIZED (CONTRACTOR TO
JOISTS WITH POST BRACKET FIELD CONFIRM BASE
NON-SLIP NOSING
C
3" 2"
8" MIN

MECHANICALLY STRINGERS), TYP NEW 4" SLAB ON BLDG MATERIAL)


FASTERED (TYP) - GRADE
BEAM, SEE PLAN 3-10M
TIES 5"
EMBEDMENT
SIMPSON
SOLID BRG
1'-6" .MIN
3" CLR

112"x18ga METAL

1'-0"

1'-6"
STRAP EACH 5" FIELD CONFIRM
STRINGER, TYP
FOUNDATION BEAM 2-2x10
NEW STAIR BEYOND ADJACENT TO
STRINGERS EXISTING

3"
4-15M VERT. BLDG, TYP
1'-0"
SEE FTG. SCEDULE
SEE FOOTING SCHEDULE FOR SIZE & REINF

TYPICAL STRINGER CONNECTION TYPICAL FTG SECTION SECTION


1A SCALE: 1"=1'-0" 5 SCALE: 1"=1'-0" C SCALE: 1"=1'-0" 7 SCALE:1"=1'-0"

SECTION
6 SCALE:1"=1'-0"

NEW FOUNDATION
REINF.
EXISTING
ELEVATION

EXISTING
FOUNDATION
WALL

THOROUGHLY
CLEAN EXIST.
CONC. SURFACE

EXISTING
FTG.
2-15M DOWELS DRILL &
GROUT WITH EPOXY
GROUT TO EXIST. CONC.
FOUNDATION. USE HILTI
HY-150 OR EQUAL
TYPICAL EXISTING TO NEW
FOUNDATION CONNECTION
N.T.S.

7 DESIGNED PROJECT JOB NUMBER

6
SIEFKEN ENGINEERING LTD. LE QUEEN'S PARK ARENA-STAIR REPLACEMENT 2016-327
CONSULTING STRUCTURAL ENGINEERS
5 DRAWN
#203-668 CARNARVON ST. 220-238 FIRST STREET SCALE
4 NEW WESTMINSTER, B.C. V3M 5Y6 NS
3 TEL: (604) 525-4122 FAX: (604) 525-3557 CHECKED
NEW WESTMINSTER, B.C. AS NOTED
E-MAIL.: [email protected]
2 ISSUED FOR TENDER OCT. 3, 2016
COPYRIGHT RESERVED
GS TITLE SHEET NUMBER

1 ISSUED FOR BUILDING PERMIT SEPT 23, 2016 This plan and design are, and at all times remain the
exclusive property of the Engineer and cannot be used or
SEAL
APPROVED
STAIR SECTIONS AND DETAILS S-5 2
REV. DESCRIPTION DATE reproduced without written consent. Do not scale drawing. JRS