GRUNDFOS DATA BOOKLET

CH, CHN

Horizontal multistage end-suction pumps


50/60 Hz
Contents

General description
Introduction 3
Applications 3
Pumped liquids 3
Operating conditions 3
Performance range 4

Identification
Type key 5

Construction
Pump 6
Motor 6
CH, CHN 2-50 7
CH, CHN 4-60 8
CH 8-50 9
CH 12-50 10
Material specification 11

Curve charts
Curve conditions 12
How to read the curve charts 13

Performance curves/
technical data
CH, CHN 50 Hz 14
CH, CHN 2 14
CH, CHN 4 16
CH 8 18
CH 12 20
CH, CHN 60 Hz 22
CH, CHN 2 22
CH, CHN 4 26
CH 8 30
CH 12 32

Pumped liquids
Pumped liquids 34
List of pumped liquids 34

Variants
Lists of variants 36
Motors 36
Shaft seals 36
Connections and other variants 36
Certificates and nameplates 36
Pumps 36

Further product documentation


WebCAPS 37
WinCAPS 38

2
General description CH, CHN

Introduction Applications
The Grundfos CH and CHN pumps are non-self- The CH and CHN pumps are designed for small
priming, horizontal, multistage centrifugal pumps. domestic and industrial systems.

Applications
• Liquid transfer and circulation of liquids within light
industry and farming
• Pressure boosting in single-pump and multi-pump
booster systems
• Domestic water supply
• Cooling systems
• Air-conditioning systems.

Pumped liquids
CH
TM03 5939 4402

Thin, clean, non-aggressive and non-explosive liquids


without solid particles or fibres.

CHN
Thin, clean, slightly aggressive and non-explosive
Pump and motor are integrated in a compact and user-
liquids without solid particles or fibres.
friendly design fittet to a base plate making the pumps
suitable for installation in compact systems.
Operating conditions
CH and CHN pumps have many incorporated advan-
tages such as those mentioned below. Liquid temperature range: *0 °C to +90 °C.
Max. ambient temperature: +55 °C.
Worldwide usage
*Lower temperatures are possible. See Lists of variants on page 36.
• Different certificates and approvals like UL/CSA for
America and Canada. The maximum operating pressure depends on the
• Different voltage and frequency combinations. temperature of the pumped liquid. See the table.
• State-of-the-art shaft seal materials (silicon carbide Max. operating pressure 1 MPa (10 bar) 0.6 MPa (6 bar)
SiC-G) offering these benefits: CH 2, CHN 2
0 °C to +40 °C +41 °C to +90 °C
- high wear resistance and long operating times CH 4, CHN 4
CH 8
- reduced risk of sticking if the liquid contains glycol CH 12
0 °C to +55 °C +56 °C to +90 °C

- improved dry-running properties due to the graphite


content of the SiC. Min. inlet pressure: According to the NPSH curve
plus a safety margin of 0.5 m.
Electro-coated cast iron parts
Max. inlet pressure: Limited by the max. operating
• High corrosion resistance.
pressure.
• Better efficiency because of smooth surfaces.

Customized solutions
See “List of Variants” on page 36.
• Motor adaptation.
• Pump body modifications.

Materials
CH: Chambers and all moving parts in contact with the
pumped liquid are made of stainless steel. Discharge
chamber, suction chamber and base plate are painted
non-gloss black.
CHN: Discharge chamber, suction chamber, base plate
and all parts in contact with the pumped liquid are made
of stainless steel.
The pump is CE-marked.

3
General description CH, CHN

Performance range
CH, CHN, 50 Hz

p H
[kPa] [m]
55
CH, CHN
50 Hz
500
50 ISO 9906 Annex A

45

400 40

35

300 30

25

200 20
CH 2 CH 4 CH 8 CH 12
CHN 2 CHN 4
15

100 10

TM02 1239 3902


5

0 0
1 2 3 4 5 6 7 8 9 10 11 12 13 Q [m³/h]

CH, CHN, 60 Hz

p H
[kPa] [m]
800
80 CH, CHN
75 60 Hz
700 ISO 9906 Annex A
70

65
600
60

55
500 50

45
400 40

35
300 30

25
200 20
CH 2 CH 4 CH 8 CH 12
15
CHN 2 CHN 4
100 10

5
TM02 1240 3902

0 0
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Q [m³/h]

0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 Q [l/s]

4
Identification Type key

Type key
Example CH(N) 4 -30 A W -A -CVBE

Type range

Rated flow rate [m³/h]

Max. discharge pressure [m]

Code for pump version

Code for physical dimensions

Code for materials, excluding plastic and rubber parts

Code for shaft seal

Codes for physical dimensions

B: NPT pipe connection


N: Different connection diameters
W: Whitworth thread, Rp ISO 7/1
O: Outside thread.
Codes for materials

A: Basic version
I: Stainless materials
X: Special version.

5
Construction CH, CHN

Pump Motor
The CH, CHN pumps are non-self-priming, horizontal, The pump is fitted with a TEFC (totally enclosed, fan-
multistage centrifugal pumps with mechanical shaft cooled), squirrel-cage Grundfos motor.
seal and through-going pump-motor shaft. The pumps
have axial suction port and radial discharge port and Rated speed: 50 Hz, 2900 min-1
are mounted on a base plate. All movable parts in 60 Hz, 3400 min-1
contact with the pumped liquid are made of stainless Enclosure class: IP 54
steel. Insulation class: F
EPDM or FKM O-rings are available as standard. Standard voltages: 1 x 220-240 V, 50 Hz
See pipe connections in the table. 3 x 220-240/380-415 V, 50 Hz
1 x 115/230 V, 60 Hz
CH 2, CH 4, 3 x 208-230/440-480 V, 60 Hz
Connections CH 8 CH 12
CHN 2 CHN 4
Rp 1 3 x 575 V, 60 Hz
Axial suction port Rp 1 Rp 1 1/2 Rp 1 1/2
Rp 1 1/4 Voltage tolerance: +6 %/–10 %
Radial discharge port Rp 1 Rp 1 Rp 1 1/4 Rp 1 1/2
Sound-pressure level: ≤70 dB (A)
Drain hole, priming hole Rp 3/8 Rp 3/8 Rp 1/2 Rp 1/2

The single-phase motors are supplied with a built-in


thermal relay to IEC 34-11, TP 211 (slow overload as
well as locked rotor). The motors require no further
motor protection.
The three-phase motors do not incorporate thermal
protection and therefore require external motor
protection in accordance with local regulations.
The sound pressure level of the pump is lower than
the limiting values stated in the EC Council Directive
98/37/EC relating to machinery.

Frequency converter operation


Most three-phase motors can be operated with a
frequency converter. See Lists of variants on page 36.

6
Construction CH, CHN

CH, CHN 2-50


Sectional drawing

164

164a 2 153 155 105 64 49

25

156
65
159

151 6
45
158

154

172

25

TM03 2039 3504


37 62 65 45 66 67

150a 28 56 28g 79

Fig. 1 CH, CHN 2-50 with MG 71 motor

Components
Pos. Component Pos. Component Pos. Component
2 Discharge chamber 56 Base plate 151 Fan cover
4 Chamber 62 Stop ring 153,154 Ball bearing
6 Suction chamber 64 Spacing pipe 155 Bearing cover plate
25 Plug 65 Retainer for neck ring 156 Fan
28 Screw 66 Clamp 158 Corrugated spring
28g Hexagon head screw 67 Lock nut 159 O-ring
37 Gasket 79 Diverting disc 164 Terminal box cover
45 Neck ring 105 Shaft seal 164a Terminal box
49 Impeller 150a Stator housing 172 Shaft

7
Construction CH, CHN

CH, CHN 4-60


Sectional drawing

164
164a 2 153 155 79 105 64 49 64a

25

156
159
151 6

158
154
172

25

TM00 6609 4900


62 37 4 4a 47a 66 67

150a 28 56 28g

Fig. 2 CH, CHN 4-60 with MG 80 motor

Components
Pos. Component Pos. Component Pos. Component
2 Discharge chamber 56 Base plate 153,154 Ball bearing
4 Chamber 62 Stop ring 155 Bearing cover plate
4a Chamber with bearing 64 Spacing pipe 156 Fan
6 Suction chamber 64a Spacing pipe 158 Corrugated spring
25 Plug 66 Clamp 159 O-ring
28 Screw 67 Lock nut 164 Terminal box cover
28g Hexagon head screw 79 Diverting disc 164a Terminal box
37 Gasket 105 Shaft seal 172 Shaft
47a Bearing 150a Stator housing
49 Impeller 151 Fan cover

8
Construction CH, CHN

CH 8-50
Sectional drawing

158 157 150a 154 172a 164 164a 2 105 37a 49 49a 37

41 1a

156

151
25

65
6
45

25

TM03 2036 3505


153 155 41a 79 193 192 191 45 65 26 64 66 67

4
Fig. 3 CH 8-50 with MG 80 motor

Components
Pos. Component Pos. Component Pos. Component
1a Pump housing 45 Neck ring 151 Fan cover
4 Chamber 49 Impeller 153,154 Ball bearing
6 Suction chamber 49a Impeller 155 Bearing cover plate
25 Plug 56 Base plate 156 Fan
26 Staybolt 64 Spacing pipe 158 Corrugated spring
28 Screw 65 Retainer for neck ring 159 O-ring
28g Hexagon head screw 66 Clamp 164 Terminal box cover
28h Serrated lock washer 67 Lock nut 164a Terminal box
37 Gasket 79 Diverting disc 172 Shaft
37a Gasket 105 Shaft seal
41 Bearing plate 150a Stator housing

9
Construction CH, CHN

CH 12-50
Sectional drawing

156 159a 158 156a 154 157 172a 164 153 2 105 37a 49 49a 37

41 1a

151

25

65
6
45

25

TM03 2037 3505


181 150a 155 79 41a 193 192 191 45 65 26 64 66 67

4
Fig. 4 CH 12-50 with MG 90 motor

Components
Pos. Component Pos. Component Pos. Component
1a Pump housing 45 Neck ring 151 Fan cover
4 Chamber 49 Impeller 153,154 Ball bearing
6 Suction chamber 49a Impeller 155 Bearing cover plate
25 Plug 56 Base plate 156 Fan
26 Staybolt 64 Spacing pipe 156a Non-drive end shield
28 Screw 65 Retainer for neck ring 157a Lip seal
28g Hexagon head screw 66 Clamp 158 Corrugated spring
28h Serrated lock washer 67 Lock nut 159 O-ring
37 Gasket 79 Diverting disc 164 Terminal box cover
37a Gasket 105 Shaft seal 172 Shaft
41 Bearing plate 150a Stator housing 181 Staybolt

10
Construction CH, CHN

Material specification
CH CHN
Pos. Description Material
DIN W.-Nr. ISO/AISI/ASTM DIN W.-Nr. ISO/AISI/ASTM
105 Shaft seal
Motor parts
62 Stop ring Stainless steel 1.4401 AISI 316 1.4401 AISI 316
Stator housing complete with Silumin/composite (MG 71 and MG 80)
150
terminal box Silumin (MG 90)
Silumin/composite (MG 71 and MG 80)
150a Stator housing
Silumin (MG 90)
Steel (MG 71 and MG 80)
151 Fan cover 1.0330.3 1.0330.3
Composite PBT/PC (MG 90)
153,
Ball bearing
154
155 Bearing cover plate Stainless steel 1.4301 AISI 304 1.4301 AISI 304
156 Fan Composite PA 66 30 % GF
156a Non-drive end shield (MG 90) Silumin
157a Lip seal (MG 90)
158 Corrugated spring
159 O-ring NBR rubber
159a Gasket
164 Terminal box cover
164a Terminal box
Pump shaft: Stainless steel 1.4057 1.4057
172 AISI 431 AISI 431
Motor shaft: Steel 1.0531 1.0531
1.4057/ 1.4057
172a Shaft, complete Stainless steel/steel AISI 431 AISI 431
1.0531 1.0531
181 Staybolt (only MG 90) Steel
Pump parts
1a Pump housing
2 Discharge chamber Cast iron/stainless steel 0.6020 ASTM 30 B 1.4308
4 Chamber Stainless steel 1.4301 AISI 304 1.4301 AISI 304
Stainless steel + aluminium oxide
4a Chamber with bearing (CH 4) Al2O3 (ceramic) 1.4301 AISI 304 1.4301 AISI 304

6 Suction chamber, complete Cast iron/stainless steel 0.6020 ASTM 30 B 1.4308


25 Plug Free-cutting steel/stainless steel 1.0718 1.4301 AISI 304
26 Staybolt Galvanized steel
28 Screw
28g Hexagon head screw
28h Serrated lock washer
37,
Gasket Synthetic-fibre-reinforced rubber (NBR)
37a
41 Bearing plate
45 Neck ring PTFE
Chromium-nickel-molybdenum-
47a Bearing (shaft) (CH 4-60)
cemented tungsten carbide
Impeller
CH 8 and 12: ∅130 mm
49 Stainless steel 1.4301 AISI 304 1.4301 AISI 304
CH, CHN 4: ∅95 mm
CH, CHN 2: ∅90 mm
49a Impeller CH 8 and 12: ∅98 mm Stainless steel 1.4301 AISI 304 1.4301 AISI 304
56 Base plate Iron/stainless steel 1.0330.3 1.4301 AISI 304
64,
Spacing pipe Stainless steel 1.4401 AISI 316 1.4401 AISI 316
64a
65 Retainer for neck ring Stainless steel 1.4301 AISI 304 1.4301 AISI 304
66 Clamp Stainless steel 1.4401 AISI 316 1.4401 AISI 316
67 Lock nut Stainless steel 1.4301 AISI 304 1.4301 AISI 304
79 Diverting disc NR rubber

11
Curve charts CH, CHN

Curve conditions
The guidelines below apply to the curves on the
following pages.
• Tolerances according to ISO 9906, Annex A.
• The bold curves state the recommended
performance range.
• The thin curves are only intended as a guide.
• The curves must not be used as guarantee curves.
• All curves are based on measurements at:
• 1 x 230 V, 50 Hz
• 3 x 400 V, 50 Hz
• 1 x 220 V, 60 Hz
• 3 x 380 V, 60 Hz.
• When the motor is running at the lowest or highest
rated voltage, the pump performance will usually
vary by ± 0.5 - 1.0 m at a given duty point.
• Specific minimum performance requirements
necessitate individual measurements.
• The measurements have been made with airless
water at a temperature of 20 °C (~70 °F).
• The conversion between head H (m) and pressure p
(kPa) applies to a water density of ρ = 1000 kg/m3.
• The curves apply to a kinematic viscosity of
υ = 1 mm2/s(1 cSt)

12
Curve charts CH, CHN

How to read the curve charts


Curves

QH: Pump performance at actual speed.


P2: Pump input power.
Eta 1:Total efficiency, i.e. pump with motor, is shown
in the curve charts as Eta 1.
NPSH: Average values for all variants shown in
chart 1. When sizing, make a safety allowance
of at least 0.5 m.

Total pump p H
[kPa] [m] CH(N) 2-60
head CH 2, CHN 2
55
H = Htotal 50 Hz
ISO 9906 Annex A
500
50
Pump type
CH(N) 2-50

45
QH curve for the
400
40 individual pump.
CH(N) 2-40
The bold curve
35 shows the
300
recommended
30 CH(N) 2-30
performance range.
25

200 20 CH(N) 2-20

15

100 10

0 0
0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 3.2 Q [m³/h]

0.0 0.2 0.4 0.6 0.8 1.0 Q [l/s]


P2 The power curve
[kW] shows the pump
-60
0.5 -50 input power [P2]
0.4 -40
0.3 -30
0.2 -20
0.1
0.0
0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 3.2 Q [m³/h]
p NPSH Eta
[kPa] [m] [%] The NPSH curve
5 50
40 4 40 is an average
Eta 1
30 3 30 curve for all
20 2 NPSH 20 variants shown.
10 1 10
TM03 8456 1607

When sizing the


0 0 0
pumps, add a
0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 3.2 Q [m³/h]
safety margin of
at least 0.5 m.

13
Performance curves/ CH 2, CHN 2
50 Hz
technical data

CH, CHN 50 Hz
CH, CHN 2

p H
[kPa] [m] CH(N) 2-60
CH 2, CHN 2
55
50 Hz
500 ISO 9906 Annex A
50
CH(N) 2-50

45

400
40
CH(N) 2-40

35

300 30 CH(N) 2-30

25

200 20 CH(N) 2-20

15

100 10

0 0
0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 3.2 Q [m³/h]

0.0 0.2 0.4 0.6 0.8 1.0 Q [l/s]


P2
[kW]
-60
0.5 -50
0.4 -40
0.3 -30
0.2 -20

0.1
0.0
0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 3.2 Q [m³/h]
p NPSH Eta
[kPa] [m] [%]
5 50
40 4 40
Eta 1
30 3 30
20 2 NPSH 20
TM03 8456 1607

10 1 10
0 0 0
0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 3.2 Q [m³/h]

14
Technical data CH 2, CHN 2
50 Hz

L4 Rp 1 B1
B2
CH, CHN 2 Rp 1
CH 2 Rp 1 Rp 3/8
CH, CHN 4 Rp
CH 4 Rp1 +1 Rp
+ Rp
1 1/41¼

155
90
ø8.5

TM00 1491 4900


Rp 3/8

L2 138 108
L3 160 130
L1

Fig. 5 Dimensional sketches, CH, CHN 2 and 4 with MG 71/80 motor

Dimensions
Voltage Frequency L1 L2 L3 L4 B1 B2 H
Pump type Motor type
[V] [Hz] [mm] [mm] [mm] [mm] [mm] [mm] [mm]
CH, CHN 2-20 MG 71 304 74 63 99 146 115 205
CH, CHN 2-30 MG 71 322 92 81 117 146 115 205
1 x 220-240 50 CH, CHN 2-40 MG 71 340 110 99 135 146 115 205
CH, CHN 2-50 MG 71 358 128 117 154 146 115 205
CH, CHN 2-60 MG 71 376 146 135 172 146 115 205
CH, CHN 2-20 MG 71 304 74 63 99 146 110 200
CH, CHN 2-30 MG 71 322 92 81 117 146 110 200
3 x 220-240/380-415 50 CH, CHN 2-40 MG 71 340 110 99 135 146 110 200
CH, CHN 2-50 MG 71 358 128 117 154 146 110 200
CH, CHN 2-60 MG 71 376 146 135 172 146 110 200
CH, CHN 2-20 MG 71 304 74 63 99 141.5 110 200
CH, CHN 2-30 MG 71 322 92 81 117 141.5 110 200
3 x 200-220/346-380 50
CH, CHN 2-40 MG 80 380 110 99 135 141.5 110 200
3 x 200-230/346-400 60
CH, CHN 2-50 MG 80 398 128 117 154 141.5 110 200
CH, CHN 2-60 MG 80 416 146 135 172 141.5 110 200

Weights
Single-phase Three-phase
Pump type Net weight Gross weight Shipping volume Net weight Gross weight Shipping volume
[kg] [kg] [m³] [kg] [kg] [m³]
CH, CHN 2-20 9.6 11.4 0.0187 11.1 11.8 0.0187
CH, CHN 2-30 9.6 11.4 0.0187 10.7 11.6 0.0187
CH, CHN 2-40 10.9 11.5 0.0187 11.0 11.7 0.0187
CH, CHN 2-50 11.3 12.0 0.0235 11.5 12.2 0.0235
CH, CHN 2-60 11.6 12.3 0.0235 11.8 12.5 0.0235

Electrical data
Voltage Frequency I1/1 Ist P1 P2 C
Pump type Motor type
[V] [Hz] [A] [A] [W] [W] [µF/V]
CH, CHN 2-20 MG 71 2.2 10.5 420 205 10/400
CH, CHN 2-30 MG 71 2.3 10.5 480 280 10/400
1 x 220-240 50 CH, CHN 2-40 MG 71 2.6 10.5 570 370 10/400
CH, CHN 2-50 MG 71 2.9 10.5 680 450 10/400
CH, CHN 2-60 MG 71 3.7 13 800 560 16/400
CH, CHN 2-20 MG 71 1.6/0.9 11.4/6.6 380 230
CH, CHN 2-30 MG 71 1.7/1 11.4/6.6 460 300
3 x 220-240/380-415 50 CH, CHN 2-40 MG 71 1.9/1.1 11.4/6.6 570 400
CH, CHN 2-50 MG 71 2.35/1.25 11.4/6.6 800 560
CH, CHN 2-60 MG 71 2.55/1.35 11.4/6.6 820 580
CH, CHN 2-20 MG 71 2.5/1.6 16.2/14.3 370 230
CH, CHN 2-30 MG 71 2.5/1.6 16.2/14.3 450 300
3 x 200-220/346-380** 50 CH, CHN 2-40 MG 80 3.3/2.1 21.6/18.8 590 400
CH, CHN 2-50 MG 80 3.4/2.1 21.6/18.8 690 490
CH, CHN 2-60 MG 80 4.0/2.3 30.8/30.8 790 600
** Dual-frequency pump; can be used for both 50 and 60 Hz in the voltage range stated.

15
Performance curves CH 4, CHN 4
50 Hz

CH, CHN 4

p H
[kPa] [m] CH(N) 4-60

500
CH 4, CHN 4
50 50 Hz
ISO 9906 Annex A
CH(N) 4-50
45

400
40

CH(N) 4-40
35

300 30
CH(N) 4-30

25

200 20
CH(N) 4-20

15

100 10

0 0
0 1 2 3 4 5 6 7 8 Q [m³/h]

0.0 0.4 0.8 1.2 1.6 2.0 Q [l/s]


P2
[kW]
1.2
-60
-50
0.8
-40
-30
0.4
-20

0.0
0 1 2 3 4 5 6 7 8 Q [m³/h]
p NPSH Eta
[kPa] [m] Eta 1 [%]
30 3 30

20 2 20
NPSH
10
TM03 8457 1607

1 10

0 0 0
0 1 2 3 4 5 6 7 8 Q [m³/h]

16
Technical data CH 4, CHN 4
50 Hz

L4 Rp 1 B1
B2
CH, CHN 2 Rp 1
CH 2 Rp 1 Rp 3/8
CH, CHN 4 Rp
CH 4 Rp1 +1 Rp
+ Rp
1 1/41¼

155
90
ø8.5

TM00 1491 4900


Rp 3/8

L2 138 108
L3 160 130
L1

Fig. 6 Dimensional sketches, CH, CHN 2 and 4 with MG 71/80 motor

Dimensions
Voltage Frequency Motor L1 L2 L3 L4 B1 B2 H
Pump type
[V] [Hz] type [mm] [mm] [mm] [mm] [mm] [mm] [mm]
CH, CHN 4-20 MG 71 314 83 72 108 146 115 205
CH, CHN 4-30 MG 71 342 110 99 135 146 115 205
1 x 220-240 50 CH, CHN 4-40 MG 71 370 137 126 163 146 115 205
CH, CHN 4-50 MG 80 438 164 153 190 141.5 135 225
CH, CHN 4-60 MG 80 466 191 180 217 141.5 135 225
CH, CHN 4-20 MG 71 314 83 72 108 146 115 200
CH, CHN 4-30 MG 71 342 110 99 135 146 110 200
3 x 220-240/380-415 50 CH, CHN 4-40 MG 71 370 137 126 163 146 110 200
CH, CHN 4-50 MG 80 438 164 153 190 141.5 110 200
CH, CHN 4-60 MG 80 466 191 180 217 141.5 110 200
CH, CHN 4-20 MG 71 314 83 72 108 141.5 110 200
3 x 200-220/346-380 50
CH, CHN 4-30 MG 80 382 110 99 135 141.5 110 200
3 x 200-230/346-400 60
CH, CHN 4-40 MG 80 410 137 126 163 141.5 110 200

Weights
Single-phase Three-phase
Pump type Net weight Gross weight Shipping volume Net weight Gross weight Shipping volume
[kg] [kg] [m³] [kg] [kg] [m³]
CH, CHN 4-20 9.5 10.1 0.0187 9.6 10.3 0.0187
CH, CHN 4-30 10.9 11.6 0.0187 11.0 11.7 0.0187
CH, CHN 4-40 12.3 13.0 0.0235 12.5 13.2 0.0235
CH, CHN 4-50 16 17.7 0.0235 14.2 14.9 0.0422
CH, CHN 4-60 15.2 16.6 0.0235 14.9 16.3 0.0422

Electrical data
Voltage Frequency I1/1 Ist P1 P2 C
Pump type Motor type
[V] [Hz] [A] [A] [W] [W] [µF/V]
CH, CHN 4-20 MG 71 2.3 11 540 345 16/400
CH, CHN 4-30 MG 71 3.9 21 840 480 25/400
1 x 220-240 50 CH, CHN 4-40 MG 71 3.9 21 1160 690 25/400
CH, CHN 4-50 MG 80 5.8 29 1300 920 30/400
CH, CHN 4-60 MG 80 6.7 29 1460 1050 50/400
CH, CHN 4-20 MG 71 1.9/1.0 11.4/6.6 560 390
CH, CHN 4-30 MG 71 2.3/1.3 11.4/6.6 820 540
3 x 220-240/380-415 50 CH, CHN 4-40 MG 71 2.8/1.6 11.4/6.6 965 660
CH, CHN 4-50 MG 80 4.0/2.3 26.0/15.0 1320 1000
CH, CHN 4-60 MG 80 4.4/2.5 26.0/15.0 1510 1170
CH, CHN 4-20 MG 71 2.6/1.5 16.2/14.3 544 390
3 x 200-220/346-380** 50 CH, CHN 4-30 MG 80 3.5/2.0 21.6/18.8 808 565
CH, CHN 4-40 MG 80 4.2/2.4 30.8/30.8 966 771
** Dual-frequency pump; can be used for both 50 and 60 Hz in the voltage range stated.

17
Performance curves CH 8
50 Hz

CH 8

p H
[kPa] [m]
600 CH 8
60
50 Hz
CH 8-60
ISO 9906 Annex A
55

500
50
CH 8-50

45

400
40
CH 8-40

35

300 CH 8-30
30

25

200 20 CH 8-20

15

100 10

0 0
0 1 2 3 4 5 6 7 8 9 Q [m³/h]

0.0 0.4 0.8 1.2 1.6 2.0 2.4 Q [l/s]


P2
[kW]
1.6 -60
1.2 -50
-40
0.8 -30

0.4 -20
0.0
0 1 2 3 4 5 6 7 8 9 Q [m³/h]
p NPSH Eta
[kPa] [m] [%]
40 Eta 1
4 40

30 3 30

20 2 NPSH 20
TM03 8458 1607

10 1 10

0 0 0
0 1 2 3 4 5 6 7 8 9 Q [m³/h]

18
Technical data CH 8
50 Hz

CH 8 Rp 1 1/4
CH 8 Rp 1 1/4 L4 B1
L4 B1 CH 12 Rp 1 1/2
CH 12 Rp 1 1/2
Rp 1/2 B2 Rp 1/2 MG 90 motor
MG 80 motor
Rp 1 1/2
Rp 1 1/2

TM00 1189 3505/TM00 1490 3505


240
240

188
188

110
110
ø8.5 ø8.5
Rp 1/2
Rp 1/2
L2 138 108
L2 138 108
L3 160 130
L3 160 130
L1
L1

Fig. 7 Dimensional sketches, CH 8

Dimensions
Voltage Frequency L1 L2 L3 L4 B1 B2
Pump type Motor type
[V] [Hz] [mm] [mm] [mm] [mm] [mm] [mm]
CH 8-20 MG 71 311 69 58 77 177 109
CH 8-30 MG 80 381 99 88 107 177 109
1 x 220-240 50 CH 8-40 MG 80 381 99 88 107 177 109
CH 8-50 MG 90 459 129 118 137 182
CH 8-60 MG 90 459 129 118 137 182
CH 8-20 MG 71 311 69 58 77 177 109
CH 8-30 MG 80 381 99 88 107 177 109
3 x 220-240/380-415 50 CH 8-40 MG 80 381 99 88 107 177 109
CH 8-50 MG 80 411 129 118 137 177 109
CH 8-60 MG 90 459 129 118 137 182
CH 8-20 MG 71 311 69 58 77 177 109
3 x 200/346 50 CH 8-25 MG 80 381 99 88 107 177 109
3 x 200-220/346-400 60 CH 8-30 MG 80 381 99 88 107 177 109
CH 8-40 MG 80 381 99 88 107 177 109
CH 8-50 MG 80 411 129 118 137 177 109
3 x 200/346 50
CH 8-60 MG 80 411 129 118 137 177 109

Weights
Single-phase Three-phase
Pump type Net weight Gross weight Shipping volume Net weight Gross weight Shipping volume
[kg] [kg] [m³] [kg] [kg] [m³]
CH 8-20 15 17 0.0422 15 17 0.0422
CH 8-25 - - - - - -
CH 8-30 17 19 0.0422 17 19 0.0422
CH 8-40 19 21 0.0422 19 21 0.0422
CH 8-50 28.8 31.6 0.0422 20 22 0.0422
CH 8-60 28.8 31.6 0.0422 25 27 0.0422

Electrical data
Voltage Frequency I1/1 Ist P1 P2 C
Pump type Motor type
[V] [Hz] [A] [A] [W] [W] [µF/V]
CH 8-20 MG 71 3.2 11 730 480 16/400
CH 8-30 MG 80 4.3 13 970 740 20/400
1 x 220-240 50 CH 8-40 MG 80 5.6 26.5 1330 940 25/400
CH 8-50 MG 90 7.8 29 1740 1310 30/400
CH 8-60 MG 90 8.5 29 1930 1460 30/400
CH 8-20 MG 71 2.1/1.2 11.4/6.6 650 480
CH 8-30 MG 80 3.4/2.0 18.2/10.5 1030 790
3 x 220-240/380-415 50 CH 8-40 MG 80 4.7/2.7 27.5/16 1290 1025
CH 8-50 MG 80 5.2/3.0 27.5/16 1650 1290
CH 8-60 MG 90 5.9/3.4 45/26 1930 1560
CH 8-20 MG 71 3.4/2.0 16.2/9.4 714 517
CH 8-25 MG 80 4.1/2.4 21.6/12.4 891 696
3 x 200/346** 50
CH 8-30 MG 80 4.0/2.3 30.0/17.4 1000 830
CH 8-40 MG 80 4.5/2.5 30.0/17.4 1720 1290
CH 8-50 MG 80 5.7/3.3 30.0/17.4 1720 1290
3 x 200/346 50
CH 8-60 MG 80 6.0/3.5 30.0/17.4 1850 1370
** Dual-frequency pump; can be used for both 50 and 60 Hz in the voltage range stated.

19
Performance curves CH 12
50 Hz

CH 12

p H
[kPa] [m]
600 CH 12-60 CH 12
60
50 Hz
ISO 9906 Annex A
55

500 CH 12-50
50

45

400 CH 12-40
40

35
CH 12-30
300 30

25

CH 12-20
200 20

15

100 10

0 0
0 2 4 6 8 10 12 14 Q [m³/h]

0 1 2 3 4 Q [l/s]
P2
[kW] -60
2.5
2.0 -50
-40
1.5
-30
1.0
-20
0.5
0.0
0 2 4 6 8 10 12 14 Q [m³/h]
p NPSH Eta
[kPa] [m] [%]
5 Eta 1 50
40 4 40
30 3 30
20 2 NPSH 20
TM03 8459 1607

10 1 10
0 0 0
0 2 4 6 8 10 12 14 Q [m³/h]

20
Technical data CH 12
50 Hz

CH 8 Rp 1 1/4
CH 8 Rp 1 1/4 L4 B1
L4 B1 CH 12 Rp 1 1/2
CH 12 Rp 1 1/2
Rp 1/2 B2 Rp 1/2 MG 90 motor
MG 80 motor
Rp 1 1/2
Rp 1 1/2

TM00 1189 3505/TM00 1490 3505


240
240

188
188

110
110
ø8.5 ø8.5
Rp 1/2
Rp 1/2
L2 138 108
L2 138 108
L3 160 130
L3 160 130
L1
L1

Fig. 8 Dimensional sketches, CH 12

Dimensions
Voltage Frequency L1 L2 L3 L4 B1 B2
Pump type Motor type
[V] [Hz] [mm] [mm] [mm] [mm] [mm] [mm]
CH 12-20 MG 80 351 69 58 77 177 109
CH 12-30 MG 80 381 99 88 107 177 109
1 x 220-240 50
CH 12-40 MG 90 429 99 88 107 182
CH 12-50 MG 90 459 129 118 137 182
CH 12-20 MG 80 351 69 58 77 177 109
CH 12-30 MG 80 381 99 88 107 177 109
3 x 220-240/380-415 50 CH 12-40 MG 90 429 99 88 107 182
CH 12-50 MG 90 459 129 118 137 182
CH 12-60 MG 90 459 129 118 137 182
CH 12-10 MG 71 311 69 58 77 177 109
3 x 200/346 50 CH 12-20 MG 80 351 69 58 77 177 109
3 x 200-220/346-380 60 CH 12-30 MG 90 429 99 88 107 182
CH 12-40 MG 90 429 99 88 107 182
CH 12-50 MG 90 459 129 118 137 182 110
3 x 200/346 50
CH 12-60 MG 90 459 129 118 137 182 110

Weights
Single-phase Three-phase
Pump type Net weight Gross weight Shipping volume Net weight Gross weight Shipping volume
[kg] [kg] [m³] [kg] [kg] [m³]
CH 12-10 - - - - - -
CH 12-20 17 19 0.0422 17 19 0.0422
CH 12-30 19 21 0.0422 19 21 0.0422
CH 12-40 26 28 0.0422 24 26 0.0422
CH 12-50 27 29 0.0422 27 29 0.0422
CH 12-60 - - - 27 29 0.0422

Electrical data
Voltage Frequency I1/1 Ist P1 P2 C
Pump type Motor type
[V] [Hz] [A] [A] [W] [W] [µF/V]
CH 12-20 MG 80 4.8 13 1060 710 20/400
CH 12-30 MG 80 6.8 26.7 1520 1080 25/400
1 x 220-240 50
CH 12-40 MG 90 9.6 42 2180 1642 50/400
CH 12-50 MG 90 11.3 42 2560 1630 50/400
CH 12-20 MG 80 3.2/1.8 18.2/10.5 1030 790
CH 12-30 MG 80 4.3/2.5 26.0/15.0 1530 1190
3 x 220-240/380-415 50 CH 12-40 MG 90 6.6/3.8 45.0/26.0 2200 1770
CH 12-50 MG 90 8.1/4.8 57.0/33.0 2690 2150
CH 12-60 MG 90 9.4/5.5 57.0/33.0 3180 2560
CH 12-10 MG 71 3.3/1.9 3.3/1.9 550 375
CH 12-20 MG 80 3.1/1.8 3.1/1.8 880 670
3 x 200/346** 50
CH 12-30 MG 90 7.0/4.0 7.0/4.0 1600 1280
CH 12-40 MG 90 9.9/5.7 9.9/5.7 1720 1290
CH 12-50 MG 90 8.5/4.9 8.5/4.9 2600 2200
3 x 200/346 50
CH 12-60 MG 90 11.4/6.5 11.4/6.5 3500 2700
** Dual-frequency pump; can be used for both 50 and 60 Hz in the voltage range stated.

21
Performance curves CH 2, CHN 2
60 Hz

CH, CHN 60 Hz
CH, CHN 2

p H
[kPa] [m] CH(N) 2-60
80 CH 2, CHN 2
60 Hz
75
ISO 9906 Annex A
700
70
CH(N) 2-50
65
600
60

55 CH(N) 2-40

500 50

45
CH(N) 2-30
400 40

35

300 30
CH(N) 2-20
25

200 20

15

100 10

0 0
0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 3.2 3.6 Q [m³/h]

0.0 0.2 0.4 0.6 0.8 1.0 Q [l/s]


P2
[kW]
1.0 -60
0.8 -50
-40
0.6
-30
0.4 -20
0.2
0.0
0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 3.2 3.6 Q [m³/h]
p NPSH Eta
[kPa] [m] [%]
80 8 40
Eta 1
60 6 30

40 4 20
TM03 8460 1607

20 2 NPSH 10

0 0 0
0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 3.2 3.6 Q [m³/h]

22
Technical data CH 2, CHN 2
60 Hz

L4 Rp 1 B1
B2
CH, CHN 2 Rp 1
CH 2 Rp 1 Rp 3/8
CH, CHN 4 Rp
CH 4 Rp1 +1 Rp
+ Rp
1 1/41¼

155
90
ø8.5

TM00 1491 4900


Rp 3/8

L2 138 108
L3 160 130
L1

Fig. 9 Dimensional sketches, CH, CHN 2 and 4 with MG 71/80 motor

Dimensions

Voltage Frequency L1 L2 L3 L4 B1 B2 H
Pump type Motor type
[V] [Hz] [mm] [mm] [mm] [mm] [mm] [mm] [mm]
CH, CHN 2-20 MG 71 304 74 63 99 141.5 135 225
1 x 110
CH, CHN 2-30 MG 71 322 92 81 117 141.5 135 225
1 x 127
60 CH, CHN 2-40 MG 80 380 110 99 135 141.5 135 225
1 x 110/220*
CH, CHN 2-50 MG 80 398 128 117 154 141.5 135 225
1 x 220
CH, CHN 2-60 MG 80 416 146 135 172 141.5 135 225
CH, CHN 2-20 ML 71 304 74 63 99 146 110 200
3 x 208-230/440-480 (USA)
CH, CHN 2-30 ML 71 322 92 81 117 146 110 200
With cUL approval
60 CH, CHN 2-40 ML 71 382 110 99 135 146 110 200
3 x 575 (Canada)
CH, CHN 2-50 ML 71 400 128 117 154 146 110 200
With cUL approval
CH, CHN 2-60 ML 80 417 146 135 172 141.5 115 200
CH, CHN 2-30 ML 71 322 92 81 117 146 145 226
1 x 115/230 (USA) CH, CHN 2-40 ML 80 381 110 99 135 141.5 145 226
60
With cUL approval CH, CHN 2-50 ML 80 399 128 117 154 141.5 145 226
CH, CHN 2-60 ML 90 416 146 135 172 141.5 145 226
CH, CHN 2-20 MG 71 304 74 63 99 141.5 110 200
CH, CHN 2-30 MG 71 322 92 81 117 141.5 110 200
3 x 200-220/346-380 (Japan) 50
CH, CHN 2-40 MG 80 380 110 99 135 141.5 110 200
3 x 200-230/346-400 (Japan) 60
CH, CHN 2-50 MG 80 398 128 117 154 141.5 110 200
CH, CHN 2-60 MG 80 416 146 135 172 141.5 110 200
* No motor protection

Weights
Single-phase Three-phase
Pump type Net weight Gross weight Shipping volume Net weight Gross weight Shipping volume
[kg] [kg] [m³] [kg] [kg] [m³]
CH, CHN 2-20 12.8 13.5 0.0187 11.1 11.8 0.0187
CH, CHN 2-30 12.8 13.5 0.0187 11.1 11.8 0.0187
CH, CHN 2-40 13 13.7 0.0235 11.3 11.9 0.0187
CH, CHN 2-50 13.3 14 0.0235 11.5 12.5 0.0235
CH, CHN 2-60 14.6 16.2 0.0235 12.0 13.0 0.0235

23
Technical data CH 2, CHN 2
60 Hz

Electrical data

Voltage Frequency I1/1 Ist P1 P2 Motor P2 C


Pump type Motor type SF
[V] [Hz] [A] [A] [W] [W] [HP] [µF/V]
CH, CHN 2-20 MG 71 6.6 29 690 350 20/400
1 x 110 60 CH, CHN 2-30 MG 71 8.7 29 880 450 20/400
CH, CHN 2-50 MG 80 11.2 13.2 1210 820 25/400
CH, CHN 2-20 MG 71 6/2.9 29 680 360 20/400
1 x 110/220* 60 CH, CHN 2-30 MG 71 7/2.9 29 800 460 20/400
CH, CHN 2-50 MG 80 11.2/5.6 13.2 1210 820 25/400
CH, CHN 2-30 MG 71 5.9 25 730 480 20/400
1 x 127 60
CH, CHN 2-50 MG 80 8.9 35 1100 800 25/400
CH, CHN 2-20 MG 71 3.1 15 530 320 20/400
CH, CHN 2-30 MG 71 3.6 15 880 520 20/400
1 x 220 60 CH, CHN 2-40 MG 80 4.7 18 1000 670 25/400
CH, CHN 2-50 MG 80 5.5 18 1200 930 25/400
CH, CHN 2-60 MG 80 7.8 21 1300 950 25/400
CH 2-20 ML 71 1.70 1.70 2.90/1.45 13.9 0.5 0.5
CH, CHN 2-30 ML 71 1.70 1.70 2.90/1.45 15.7 0.5 0.5
3 x 208-230/440-480 (USA)
60 CH, CHN 2-40 ML 71 1.70 1.70 4.20/2.10 20.7 0.75 0.75
With cUL approval
CH, CHN 2-50 ML 71 1.70 1.70 4.20/2.10 20.7 0.75 0.75
CH, CHN 2-60 ML 80 1.60 1.60 5.20/2.60 32.0 1 1
CH 2-20 ML 71 1.60 1.60 9.00/4.50 24.9 0.5 0.5 40/400
CH, CHN 2-30 ML 71 1.60 1.60 9.00/4.50 24.9 0.5 0.5 40/400
1 x 115/230 (USA)
60 CH, CHN 2-40 ML 80 1.50 1.50 11.5/5.70 34.0 0.75 0.75 40/400
With cUL approval
CH, CHN 2-50 ML 80 1.50 1.50 11.5/5.70 34.0 0.75 0.75 40/400
CH, CHN 2-60 ML 80 1.50 1.50 15.0/7.50 48.0 1 1 50/400
CH 2-20 ML 71 1.70 1.70 1.16 5.1 0.5 0.5
CH, CHN 2-30 ML 71 1.70 1.70 1.16 15.7 0.5 0.5
3 x 575 (Canada)
60 CH, CHN 2-40 ML 71 1.70 1.70 1.68 8.0 0.75 0.75
With cUL approval
CH, CHN 2-50 ML 71 1.70 1.70 1.68 8.0 0.75 0.75
CH, CHN 2-60 ML 80 1.60 1.60 2.08 11.2 1 1
CH, CHN 2-20 MG 71 2/1.1 15.7/9.1 520 380
CH, CHN 2-30 MG 71 2.2/1.3 15.7/9.1 670 510
3 x 200-230/346-400** (Japan) 60 CH, CHN 2-40 MG 80 2.8/1.6 20.7/12.0 860 680
CH, CHN 2-50 MG 80 3.3/1.9 20.7/12.0 1000 820
CH, CHN 2-60 MG 80 3.9/2.2 32/18.4 1200 980
* No motor protection.
** Dual-frequency pump; can be used for both 50 and 60 Hz in the voltage range stated.

24
25
Performance curves CH 4, CHN 4
60 Hz

CH, CHN 4

p H
[kPa] [m]
500
CH(N) 4-40 CH 4, CHN 4
50 60 Hz
ISO 9906 Annex A
45

400
40
CH(N) 4-30

35

300 30

CH(N) 4-20
25

200 20

15

100 10

0 0
0 1 2 3 4 5 6 7 8 9Q [m³/h]

0.0 0.4 0.8 1.2 1.6 2.0 2.4 Q [l/s]


P2
[kW]
1.2
-40
0.8
-30
-20
0.4

0.0
0 1 2 3 4 5 6 7 8 9Q [m³/h]
p NPSH Eta
[kPa] [m] [%]
40 4 Eta 1 40

30 3 30

20 2 20
NPSH
TM03 8461 1607

10 1 10

0 0 0
0 1 2 3 4 5 6 7 8 9Q [m³/h]

26
Technical data CH 4, CHN 4
60 Hz

L4 Rp 1 B1
B2
CH, CHN 2 Rp 1
CH 2 Rp 1 Rp 3/8
CH, CHN 4 Rp
CH 4 Rp1 +1 Rp
+ Rp
1 1/41¼

155
90
ø8.5

TM00 1491 4900


Rp 3/8

L2 138 108
L3 160 130
L1

Fig. 10 Dimensional sketches, CH, CHN 2 and 4 with MG 71/80 motor

Dimensions

Voltage Frequency L1 L2 L3 L4 B1 B2 H
Pump type Motor type
[V] [Hz] [mm] [mm] [mm] [mm] [mm] [mm] [mm]
1 x 110
CH, CHN 4-20 MG 71 314 83 72 108 141.5 135 225
1 x 110/220*
60 CH, CHN 4-30 MG 80 382 110 99 135 141.5 135 225
1 x 127
CH, CHN 4-40 MG 80 410 137 126 163 141.5 135 225
1 x 220
CH, CHN 4-20 ML 71 314 83 72 108 146 110 200
3 x 208-230/440-480 (USA) CH, CHN 4-30 ML 71 382 110 99 135 146 110 200
60
With cUL approval CH, CHN 4-40 ML 80 411 137 126 163 141.5 115 200
CH, CHN 4-50 ML 80 439 164 153 190 141.5 115 200
CH, CHN 4-20 ML 71 314 83 72 108 146 110 226
CH, CHN 4-30 ML 71 342 83 72 108 146 145 226
1 x 115/230 (USA)
60 CH, CHN 4-40 ML 80 411 110 99 135 141.5 145 226
With cUL approval
CH, CHN 4-50 ML 80 439 137 126 163 141.5 145 226
CH, CHN 4-60 ML 90 504 164 153 190 191 132 205
CH, CHN 4-20 ML 71 314 83 72 108 146 110 200
CH, CHN 4-30 ML 71 342 83 72 108 146 110 200
3 x 575 (Canada)
60 CH, CHN 4-40 ML 71 370 110 99 135 146 110 200
With cUL approval
CH, CHN 4-50 ML 80 439 137 126 163 141.5 115 200
CH, CHN 4-60 ML 80 467 164 153 190 141.5 115 200
CH, CHN 4-20 MG 71 314 83 72 108 141.5 110 200
3 x 200-220/346-380 (Japan) 50
CH, CHN 4-30 MG 80 382 110 99 135 141.5 110 200
3 x 200-230/346-400 (Japan) 60
CH, CHN 4-40 MG 80 410 137 126 163 141.5 110 200
* No motor protection

Weights
Single-phase Three-phase
Pump type Net weight Gross weight Shipping volume Net weight Gross weight Shipping volume
[kg] [kg] [m³] [kg] [kg] [m³]
CH, CHN 4-20 12 12.7 0.0187 10.9 11.6 0.0187
CH, CHN 4-30 13.4 14.1 0.0235 12.3 13.0 0.0235
CH, CHN 4-40 14.2 15.2 0.0235 13.8 14.5 0.0235
CH, CHN 4-50 - - - - - -
CH, CHN 4-60 - - - - - -

27
Technical data CH 4, CHN 4
60 Hz

Electrical data
Voltage Frequency I1/1 Ist P1 P2 Motor P2 C
Pump type Motor type SF
[V] [Hz] [A] [A] [W] [W] [HP] [µF/V]
CH, CHN 4-20 MG 71 8.4 29 950 550 20/400
1 x 110 60 CH, CHN 4-30 MG 80 13.8 36 1500 970 25/400
CH, CHN 4-40 MG 80 15.6 62 1860 1200 30/400
CH, CHN 4-20 MG 71 8.8/5.9 29.0/15.0 980 590 20/400
1 x 110/220* 60 CH, CHN 4-30 MG 80 13.8/7 36.0/18.0 1520 920 25/400
CH, CHN 4-40 MG 80 16.0/8.1 62.0/32.0 1720 1220 30/400
CH, CHN 4-20 MG 71 7.2 25 920 620 20/400
1 x 127 60 CH, CHN 4-30 MG 80 10.8 35 1360 890 25/400
CH, CHN 4-40 MG 80 14 50 1720 1220 30/400
CH, CHN 4-20 MG 71 4.2 15 950 550 20/400
1 x 220 60 CH, CHN 4-30 MG 80 7.0 18 1500 970 25/400
CH, CHN 4-40 MG 80 7.8 32 1860 1200 30/400
CH, CHN 4-20 ML 71 1.70 1.70 2.90/1.45 15.7 0.5 0.5
3 x 208-230/440-480 (USA) CH, CHN 4-30 ML 71 1.70 1.70 4.20/2.10 20.7 0.75 0.75
60
With cUL approval CH, CHN 4-40 ML 80 1.60 1.60 5.20/2.60 33.9 1.0 1.0
CH, CHN 4-50 ML 80 1.47 1.47 6.90/3.50 42.0 1.5 1.5
CH, CHN 4-20 ML 71 1.60 1.60 9.00/4.50 24.9 0.5 0.5 40/400
1 x 115/230 (USA) CH, CHN 4-30 ML 71 1.50 1.50 11.5/5.70 34.0 0.75 0.75 40/400
60
With cUL approval CH, CHN 4-40 ML 80 1.50 1.50 15.0/7.50 33.9 1.0 1.0 50/400
CH, CHN 4-50 ML 90 1.40 1.40 21.5/10.7 33.9 1.5 1.5 60/400
CH, CHN 4-20 ML 71 1.70 1.70 1.16 5.1 0.5 0.5
3 x 575 (Canada) CH, CHN 4-30 ML 71 1.70 1.70 1.68 8.0 0.75 0.75
60
With cUL approval CH, CHN 4-40 ML 80 1.60 1.60 2.08 11.2 1.0 1.0
CH, CHN 4-50 ML 80 1.47 1.47 2.80 15.3 1.5 1.5
CH, CHN 4-20 MG 71 2.7/1.5 15.7/9.1 811 616
3 x 200-230/346-400** (Japan) 60 CH, CHN 4-30 MG 80 4.0/2.3 20.7/12.0 1261 893
CH, CHN 4-40 MG 80 4.9/2.8 33.9/19.6 1526 1202
* No motor protection.
**Dual-frequency pump; can be used for both 50 and 60 Hz in the voltage range stated.

28
29
Performance curves CH 8
60 Hz

CH 8

p H
[kPa] [m]
CH 8
55
CH 8-40 60 Hz
500 ISO 9906 Annex A
50

45
CH 8-30

400
40

35

300 CH 8-25
30
CH 8-20
25

200 20

15

100 10

0 0
0 1 2 3 4 5 6 7 8 9 10 11 Q [m³/h]

0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 3.2 Q [l/s]
P2
[kW]
1.6 -40
-30
1.2
-25
0.8 -20

0.4

0.0
0 1 2 3 4 5 6 7 8 9 10 11 Q [m³/h]
p NPSH Eta
[kPa] [m] [%]
30 3 60
Eta 1
20 2 40
TM03 8462 1607

10 1 NPSH 20

0 0 0
0 1 2 3 4 5 6 7 8 9 10 11 Q [m³/h]

30
Technical data CH 8
60 Hz

CH 8 Rp 1 1/4
CH 8 Rp 1 1/4 L4 B1
L4 B1 CH 12 Rp 1 1/2
CH 12 Rp 1 1/2
Rp 1/2 B2 Rp 1/2 MG 90 motor
MG 80 motor
Rp 1 1/2
Rp 1 1/2

TM00 1189 3505/TM00 1490 3505


240
240

188
188

110
110
ø8.5 ø8.5
Rp 1/2
Rp 1/2
L2 138 108
L2 138 108
L3 160 130
L3 160 130
L1
L1

Fig. 11 Dimensional sketches, CH 8

Dimensions

Voltage Frequency L1 L2 L3 L4 B1 B2
Pump type Motor type
[V] [Hz] [mm] [mm] [mm] [mm] [mm] [mm]
CH 8-20 MG 80 351 69 58 77 177 109
1 x 220 60 CH 8-30 MG 90 429 99 88 107 182
CH 8-40 MG 90 429 99 88 107 182
3 x 208-230/440-480 (USA)
With cUL approval
CH 8-20 MG/ML 71 311 69 58 77 177 109
3 x 575 (Canada) CH 8-25 MG/ML 80 381 99 88 107 177 109
With cUL approval 60
CH 8-30 MG/ML 80 381 99 88 107 177 109
3 x 200/346 (Japan) CH 8-40 MG/ML 80 381 99 88 107 177 109
3 x 200-220/346-400 (Japan)
CH 8-20 ML 80 351 69 58 77 177 124
1 x 115/230 (USA) CH 8-25 ML 80 381 99 88 107 177 124
60
With cUL approval CH 8-30 ML 90 429 99 88 107 191 132
CH 8-40 ML 90 429 99 88 107 191 132
* No motor protection
Note: ML motors with cUL approval for USA and Canada.

Weights
Single-phase Three-phase
Pump type Net weight Gross weight Shipping volume Net weight Gross weight Shipping volume
[kg] [kg] [m³] [kg] [kg] [m³]
CH 8-20 18 20 0.0422 15.7 18.5 0.0422
CH 8-25 19 21 0.0422 17.0 19.8 0.0422
CH 8-30 26 28 0.0422 18.7 21.5 0.0422
CH 8-40 26 28 0.0422 19.0 21.8 0.0422

Electrical data
Voltage Frequency I1/1 Ist P1 P2 Motor P2 C
Pump type Motor type SF
[V] [Hz] [A] [A] [W] [W] [HP] [µF/V]
CH 8-20 MG 80 5.4 21 1170 830 25/400
1 x 220 60 CH 8-30 MG 90 8.9 40 1920 1350 30/400
CH 8-40 MG 90 10.4 40 2210 1570 30/400
CH 8-20 ML 71 1.70 1.70 4.20/2.10 15.6 0.75 0.75
3 x 208-230/440-480 (USA) CH 8-25 ML 80 1.60 1.60 5.20/2.60 20.4 1 1
60
With cUL approval CH 8-30 ML 80 1.47 1.47 6.90/3.50 32.0 1.5 1.5
CH 8-40 ML 80 1.47 1.47 6.90/3.50 32.0 1.5 1.5
CH 8-20 ML 80 1.50 1.50 11.5/5.70 34.0 0.75 0.75 40/400
1 x 115/230 (USA) CH 8-25 ML 80 1.50 1.50 15.0/7.50 48.0 1 1 50/400
60
With cUL approval CH 8-30 ML 90 1.40 1.40 21.5/10.7 83.0 1.5 1.5 60/400
CH 8-40 ML 90 1.40 1.40 21.4/10.6 32.0 1.5 1.5 60/400
CH 8-20 ML 71 1.70 1.70 1.68 8.0 0.5 0.5
3 x 575 (Canada) CH 8-25 ML 80 1.60 1.60 2.08 11.2 1 1
60
With cUL approval CH 8-30 ML 80 1.47 1.47 2.80 15.3 1.5 1.5
CH 8-40 ML 80 1.47 1.47 2.80 15.3 1.5 1.5
CH 8-20 MG 71 3.5/2.0 15.6/9.0 1084 859
CH 8-25 MG 80 4.5/2.6 20.4/11.8 1418 1152
3 x 200-230/346-400** (Japan) 60
CH 8-30 MG 80 5.9/3.4 32.0/18.4 1830 1400
CH 8-40 MG 80 7.6/4.4 32.0/18.8 2260 1620
** Dual frequency pump; can be used for both 50 and 60 Hz in the voltage range stated.

31
Performance curves CH 12
60 Hz

CH 12

p H
[kPa] [m]
600 CH 12
60
CH 12-40 60 Hz
ISO 9906 Annex A
55

500
50

CH 12-30
45

400
40

35

300 30 CH 12-20

25

200 20

CH 12-10
15

100 10

0 0
0 2 4 6 8 10 12 14 16 Q [m³/h]

0 1 2 3 4 Q [l/s]
P2
[kW]
-40
3

-30
2
-20
1
-10
0
0 2 4 6 8 10 12 14 16 Q [m³/h]
p NPSH Eta
[kPa] [m] [%]
60 6 60
Eta 1

40 4 40
TM03 8463 1607

20 2 NPSH 20

0 0 0
0 2 4 6 8 10 12 14 16 Q [m³/h]

32
Technical data CH 12
60 Hz

CH 8 Rp 1 1/4
CH 8 Rp 1 1/4 L4 B1
L4 B1 CH 12 Rp 1 1/2
CH 12 Rp 1 1/2
Rp 1/2 B2 Rp 1/2 MG 90 motor
MG 80 motor
Rp 1 1/2
Rp 1 1/2

TM00 1189 3505/TM00 1490 3505


240
240

188
188

110
110
ø8.5 ø8.5
Rp 1/2
Rp 1/2
L2 138 108
L2 138 108
L3 160 130
L3 160 130
L1
L1

Fig. 12 Dimensional sketches, CH 12

Dimensions

Voltage Frequency L1 L2 L3 L4 B1 B2
Pump type Motor type
[V] [Hz] [mm] [mm] [mm] [mm] [mm] [mm]
1 x 220 60 CH 12-20 MG 90 399 69 58 77 182
CH 12-10 ML 71 311 69 58 77 177 109
3 x 208-230/440-480 (USA)
60 CH 12-20 ML 80 351 69 58 77 177 109
With cUL approval
CH 12-30 ML 90 429 99 88 107 186 124
1 x 115/230 (USA) CH 12-10 ML 71 311 69 58 77 177
60
With cUL approval CH 12-20 ML 90 399 69 58 77 191 132
CH 12-10 ML 71 311 69 58 77 177 109
3 x 575 (Canada)
60 CH 12-20 ML 80 351 69 58 77 177 109
With cUL approval
CH 12-30 ML 90 429 99 88 107 186 124
CH 12-10 MG 71 311 69 58 77 177 109
3 x 200/346 (Japan) 50 CH 12-20 MG 80 351 69 58 77 177 109
3 x 200-220/346-380 (Japan) 60 CH 12-30 MG 90 429 99 88 107 182
CH 12-40 MG 90 429 99 88 107 182
* No motor protection

Weights
Single-phase Three-phase
Pump type Net weight Gross weight Shipping volume Net weight Gross weight Shipping volume
[kg] [kg] [m³] [kg] [kg] [m³]
CH 12-10 15 17 0.0422 15.7 18.5 0.0422
CH 12-20 27 29 0.0422 18.8 21.6 0.0422
CH 12-30 - - - 26.1 28.9 0.0422
CH 12-40 - - - 28.9 31.7 0.0422
CH 12-50 - - - - - -
CH 12-60 - - - - - -

Electrical data
Voltage Frequency I1/1 Ist P1 P2 Motor P2 C
Pump type Motor type SF
[V] [Hz] [A] [A] [W] [W] [HP] [µF/V]
1 x 220 60 CH 12-20 MG 90 9.2 40 1980 1430 30/400
CH 12-10 ML 71 1.70 1.70 2.90/1.45 15.7 0.5 0.5
3 x 208-230/440-480 (USA)
60 CH 12-20 ML 80 1.47 1.47 6.90/3.50 32.0 1.5 1.5
With cUL approval
CH 12-30 ML 90 1.50 1.50 9.10/4.75 46.0 2 2
1 x 115/230 (USA) CH 12-10 ML 71 1.60 1.60 9.00/4.50 24.9 0.5 0.5 40/400
60
With cUL approval CH 12-20 ML 90 1.40 1.40 21.5/10.7 83.0 1.5 1.5 60/400
CH 12-10 ML 71 1.70 1.70 1.16 5.1 0.5 0.5
3 x 575 (Canada)
60 CH 12-20 ML 80 1.47 1.47 2.80 15.3 1.5 1.5
With cUL approval
CH 12-30 ML 90 1.50 1.50 3.80 28.0 2 2
CH 12-10 MG 71 2.75/1.6 2.75/1.6 820 650
CH 12-20 MG 80 5.7/3.3 5.7/3.3 1770 1360
3 x 200-230/346-400** (Japan) 60
CH 12-30 MG 90 8.6/5.0 8.6/5.0 2680 2130
CH 12-40 MG 90 11.6/6.7 11.6/6.7 3500 2740
** Dual-frequency pump; can be used for both 50 and 60 Hz in the voltage range stated.

33
Pumped liquids CH, CHN

Pumped liquids The list should, however, be applied with some caution
as factors such as concentration of the pumped liquid,
Thin, non-explosive liquids, not containing solid
liquid temperature or pressure may affect the chemical
particles or fibres. The liquid must not chemically attack
resistance of a specific pump version.
the pump materials.
Safety precautions must be made when pumping
When pumping liquids with a density and/or viscosity
dangerous liquids.
higher than those of water, oversized motors must be
used, if required. Notes
Whether a pump is suitable for a particular liquid May contain additives or impurities which can cause shaft seal
a
problems.
depends on a number of factors of which the most The density and viscosity may differ from those of water.
b
important are the chloride content, pH value, Consider this when calculating motor and pump performance.
temperature and content of chemicals and oils. c In order to avoid corrosion, the liquid must be free of oxygen.
Flammable or combustible liquid.
Please note that aggressive liquids (for instance Safety precautions must be considered to ensure safe handling
seawater and some acids) may attack or dissolve the d of flammable liquids. Handling the liquid above the flashpoint
and/or boiling point will require the greatest restrictions.
protective oxide film of the stainless steel and thus A seal-less pump may be required. Contact Grundfos.
cause corrosion. e Risk of crystallization/precipitation on the shaft seal.
f If oil residues are present, EPDM cannot be used.

List of pumped liquids


A number of typical liquids are listed below.
Other pump versions may be applicable, but those
stated in the list are considered to be the best choices.
The table is intended as a general guide only and
cannot replace actual testing of the pumped liquids and
pump materials under specific working conditions.
Pumped liquids Notes Additional information CH CHN
Water
Boiler feed water AQQE/CVBE AQQE/CVBE
Condensate AQQE/CVBE AQQE/CVBE
Cooling and cutting lubricant a AQQV AQQV
Groundwater < 300 ppm chloride AQQE/CVBE AQQE/CVBE
Demineralised water AQQE/CVBE
District heating water AQQE/CVBE AQQE/CVBE
Oil-containing water AQQV/CVBV AQQV/CVBV
Softened water AQQE/CVBE AQQE/CVBE
40 °C, 150 ppm chloride,
Swimming pool water, chlorinated AQQE/CVBE AQQE/CVBE
< 2 ppm free chlorine
Coolants
Ethylene glycol a, b < 50 °C AQQE AQQE
Glycerine (glycerol) a, b < 50 °C AQQE AQQE
Hydrocarbon-based coolant b, d 50 °C AQQV AQQV
Potassium acetate (inhibited) a, b, c, e < 20 °C AQQE AQQE
Potassium formate (inhibited) a, b, c, e < 20 °C AQQE AQQE
Propylene glycol a, b < 50 °C AQQE AQQE
Fuels
Diesel oil d AQQV/CVBV AQQV/CVBV
Jet fuel d AQQV/CVBV AQQV/CVBV
Kerosene d AQQV/CVBV AQQV/CVBV
Naphta d AQQV/CVBV AQQV/CVBV
Petrol d AQQV/CVBV AQQV/CVBV
Biodiesel d AQQV/CVBV AQQV/CVBV
Mineral oils
Crude oil a, b, d < 20 °C AQQV/CVBV AQQV/CVBV
Mineral lubricating oil b, d AQQV/CVBV AQQV/CVBV
Mineral motor oil b, d AQQV/CVBV AQQV/CVBV
Synthetic oils
Synthetic lubricating oil b, d AQQV/CVBV AQQV/CVBV
Synthetic motor oil b, d AQQV/CVBV AQQV/CVBV
Silicone oil b AQQV/CVBV AQQV/CVBV

34
Pumped liquids CH, CHN

Pumped liquids Notes Additional information CH CHN


Vegetable oils
Corn oil a, b AQQV/CVBV AQQV/CVBV
Olive oil a, b AQQV/CVBV AQQV/CVBV
Peanut oil a, b AQQV/CVBV AQQV/CVBV
Rape-seed oil a, b AQQV/CVBV AQQV/CVBV
Soya oil a, b AQQV/CVBV AQQV/CVBV
Cleaning
Alkaline degreasing agent a, f < 80 °C AQQE AQQE
Soap (salts of fatty acids) a < 80 °C AQQV AQQV
Organic solvents
Acetone e 40 °C AQQE/CVBE AQQE/CVBE
Ethyl alcohol (ethanol) e 40 °C AQQE/CVBE AQQE/CVBE
Isopropyl alcohol e 40 °C AQQE/CVBE AQQE/CVBE
Methyl alcohol (methanol) e 40 °C AQQE/CVBE AQQE/CVBE
Oxidants
Hydrogen peroxide 20 °C, 5 % AQQE/CVBE
Salts
20 °C, 15 % AQQE
Ammonium bicarbonate b
60 °C, 30 % AQQE
20 °C, 20 % AQQE/AQQV
Potassium bicarbonate b
60 °C, 30 % AQQE/AQQV
20 °C, 20 % AQQE
Sodium carbonate b, e
60 °C, 30 % AQQE
Potassium permanganate 20 °C, 1 % AQQE/AQQV
20 °C, 5 % AQQE/AQQV
Sodium nitrate b
60 °C, 30 % AQQE/AQQV
20 °C, 20 % AQQE/AQQV
Sodium nitrite b
60 °C, 30 % AQQE/AQQV
Sodium phosphate (mono) b 60 °C, 5 % AQQE/AQQV
30 °C, 30 % AQQE/AQQV
Sodium phosphate (di) b
60 °C, 30 % AQQE/AQQV
20 °C, 10 % AQQE/AQQV
Sodium phosphate (tri) b, e
70 °C, 20 % AQQE/AQQV
Sodium sulphate b, e 60 °C, 30 % AQQE/AQQV
20 °C, 1 % AQQE/AQQV
Sodium sulphite b, e
60 °C, 20 % AQQE/AQQV
Acids
Acetic acid 20 °C, 5 % AQQE
Citric acid 20 °C, 1 % AQQE
Nitric acid b 20 °C, 5 % AQQE/AQQV
Phosphoric acid a 20 °C, 1 % AQQE/AQQV
Alkalies
Ammonium hydroxide 30 °C, 30 % AQQE AQQE
Calcium hydroxide a 30 °C, 5 % AQQE AQQE
Potassium hydroxide b, e 20 °C, 20 % AQQE
60 °C, 20 % AQQE
Sodium hydroxide b, e 20 °C, 20 % AQQE
80 °C, 20 % AQQE

35
Variants CH, CHN

Lists of variants Certificates and nameplates


Although the Grundfos CH, CHN product range offers a
Certificate of compliance with the order
number of pumps for different applications, customers
Test certificate
require specific pump solutions to satisfy their needs. Certificates
Inspection certificate
Below are the options available for customizing the CH. Standard test report
Contact Grundfos for further information or for requests Extra nameplate
other than the ones mentioned below. If the UL-listed product according to
UL778 is not available, a pump with UR-
UR-marked motor
marked motor according to UL1004 can
Motors be offered as an alternative.

Grundfos offers motors with bimetallic thermal


Motor with
thermal protection
switches or temperature-controlled PTC Pumps
sensors (thermistors) in the motor windings.
In installations where one of the conditions Exposed to temperatures below –20 °C,
mentioned below is present, the motor size coolant pumps may require neck rings
must be evaluated to make sure there will be no with a different diameter or without a
risk of overload. neck ring in order to prevent impeller
• Ambient temperatures above 55 °C. Low-temperature pump drag. If neck rings are removed, a
Oversize motor reduction of the head must be expected.
• Liquid temperatures below 0 °C.
• Installation at an altitude of more than In some extreme cases, –25 °C cold
1000 metres above sea level liquids can be pumped by a CH pump.
• Use of glycol or other high-viscous liquids. Contact Grundfos.
Alternative motors are available on request.
In some cases the standard product can run at
Dual-voltage dual voltage and frequency. If the standard
motors 50/60 hz product cannot be used for dual voltage, a
bigger motor can very often be used instead.
For most three-phase CH, CHN pumps a
frequency converter can be used. Single-phase
motors are not suitable for frequency converter
operation. In many cases where an external
frequency converter is used it is necessary to
protect the motor against voltage peaks higher
Use of external
than 650 V (peak value). In these cases it is
frequency
often less expensive to ask for phase insulation
converter
in the pump than use a filter such as an LC filter.
Grundfos offers pumps with phase insulation to
protect the pump against voltage peaks up to
1000 V (peak values). This is a customized
version, and the supplier of the frequency
converter must be consulted.
Harting plugs are available for easier
Harting plug
replacement of pumps.
Terminal box
Other terminal box positions are possible.
position

Shaft seals
CVBV, CVBE, AQQE, AQQV are standard for CH, CHN pumps.
Shaft seals with FFKM or FXM O-ring material are recommended
for applications where the pumped liquid may damage the standard
O-ring material.

Connections and other variants


Pipe connections NPT and Rp threads are available.

36
Further product CH, CHN

documentation

WebCAPS
WebCAPS is a Web-based Computer Aided Product
Selection program available on www.grundfos.com.
WebCAPS contains detailed information on more than
185,000 Grundfos products in more than 20 languages.
In WebCAPS, all information is divided into 6 sections:
• Catalogue
• Literature
• Service
• Sizing
• Replacement
• CAD drawings.

Catalogue

This section is based on fields of application and pump types, and


contains
• technical data
• curves (QH, Eta, P1, P2, etc) which can be adapted to the den-
sity and viscosity of the pumped liquid and show the number of
pumps in operation
• product photos
• dimensional drawings
• wiring diagrams
• quotation texts, etc.

Literature

In this section you can access all the latest documents of a given
pump, such as
• data booklets
• installation and operating instructions
• service documentation, such as Service kit catalogue and
Service kit instructions
• quick guides
• product brochures.

Service

This section contains an easy-to-use interactive service catalogue.


Here you can find and identify service parts of both existing and dis-
continued Grundfos pumps.
Furthermore, this section contains service videos showing you how
to replace service parts.

37
Further product CH, CHN

documentation

Sizing 0 1

This section is based on different fields of application and installa-


tion examples, and gives easy step-by-step instructions in how to
• select the most suitable and efficient pump for your installation
• carry out advanced calculations based on energy consumption,
payback periods, load profiles, life cycle costs, etc.
• analyse your selected pump via the built-in life cycle cost tool
• determine the flow velocity in wastewater applications, etc.

Replacement

In this section you find a guide to selecting and comparing replace-


ment data of an installed pump in order to replace the pump with a
more efficient Grundfos pump.
The section contains replacement data of a wide range of pumps
produced by other manufacturers than Grundfos.

Based on an easy step-by-step guide, you can compare Grundfos


pumps with the one you have installed on your site. When you have
specified the installed pump, the guide will suggest a number of
Grundfos pumps which can improve both comfort and efficiency.

CAD drawings

In this section it is possible to download 2-dimensional (2D) and 3-


dimensional (3D) CAD drawings of most Grundfos pumps.

These formats are available in WebCAPS:

2-dimensional drawings:
• .dxf, wireframe drawings
• .dwg, wireframe drawings.

3-dimensional drawings:
• .dwg, wireframe drawings (without surfaces)
• .stp, solid drawings (with surfaces)
• .eprt, E-drawings.

WinCAPS
WinCAPS is a Windows-based Computer Aided
Product Selection program containing detailed informa-
tion on more than 185,000 Grundfos products in more
than 20 languages.
The program contains the same features and functions
as WebCAPS, but is an ideal solution if no Internet
connection is available.
WinCAPS is available on CD-ROM and updated once a
year.
Fig. 13 WinCAPS CD-ROM

38
39
Being responsible is our foundation
Thinking ahead makes it possible
Innovation is the essence

V7173560 0407
Repl. V7173560 0107
GB
Subject to alterations.

GRUNDFOS A/S . DK-8850 Bjerringbro . Denmark


Telephone: +45 87 50 14 00

www.grundfos.com

You might also like