PLEASE NOTE
Electrical equipment should be installed, operated, serviced, and maintained only by qualified personnel. No
responsibility is assumed by Schneider Electric or any of its affiliates or subsidiaries (hereinafter, referred to
as Schneider Electric) for any consequences arising out of the use of this material.
A qualified person is one who has skills and knowledge related to the construction and operation of electrical
equipment and its installation, and has received safety training to recognize and avoid the hazards involved.
Copyright © 2018 Schneider Electric Japan Holdings Ltd. All Rights Reserved.
1 / 51
About the Book
Overview
Document Scope;
This book describes the following contents.
・ How to connect this product to CNC made by FANUC Corporation
・ How to configure settings using every setting tool
Related manual
Download manuals and technical information from our Web site.
http://www.pro-face.com/trans/en/manual/1001.html
2 / 51
1. Overview
This product can collect data from machine tools by communicating with CNC made by FANUC Corporation.
・ Able to transfer operating status of machine tools to MT-LINKi.
・ Able to configure settings of the main unit using settings on the Web browser without a
screen-creation editor.
・ Able to support DPRNT function as serial connection.
2. Important Notes
・ The contents and descriptions of this book are subject to change without notice.
・ This book describes contents dedicated to the product (Multi-Converter for CNC made by FANUC
corporation) that is created with customizing a Pro-face product for FANUC Corporation.
・ For details of the hardware, refer to [LT-4201TM/4301TM/4000M Hardware Manual] or
specifications of ‘PFXLM4B01DAK(model)’ in the [LT-4201TM/4301TM Installation Guide].
<Download>
http://www.pro-face.com/trans/en/manual/1001.html
3 / 51
3. Device Configuration
3.1. System Configuration
4 / 51
3.2. Compatible CNC
Yes: Able to connect No: Unable to connect
Ethernet I/O Converter
MT-Linki-compatible devices RS-232C signal
I/O signal (DPRNT)
The contents in the list above are for standard models of FANUC.
The connection methods might not be compatible depending on a configuration of every option model.
Also, a version upgrade of a feature for using DPRNT might be required depending on a configuration.
In this case, the customers are to pay for the version upgrade.
For inquiries about compatible CNC, please contact FANUC Corporation directly.
5 / 51
3.3. Operating Environment
3.3.1. Target Confirmation Tool
Items Definition
PC model PC/AT compatible machine
Target OS and its version ・Windows 7 32/64 bits (Service Pack 1 or later)
・Windows 8/8.1 32/64 bits
・Windows 10 32/64 bits
Programs required for operation of the Required for PC FEP compatible with OS in every country
product except OS and their versions (for from the (Global IME)
example, FEP) beginning
Need installing .Net Framework 3.0
6 / 51
3.3.2. User Management Tool
Items Definition
PC model PC/AT compatible machine
Target OS and its version ・ Windows 7 32/64 bits (Service Pack 1 or later)
・ Windows 8/8.1 32/64 bits
・ Windows 10 32/64 bits
Programs required for operation of the Required for PC FEP compatible with OS in every country
product except OS and their versions (for from the (Global IME)
example, FEP) beginning
Need installing Microsoft .NET Framework 4.5.2
7 / 51
3.4. Package Contents
8 / 51
3.5. External Specifications
This shows the external dimensions of the Multi-Converter for FANUC CNC.
9 / 51
3.6. Interface Specifications
B Rear module
G Ethernet Interface
10 / 51
3.6.1. Input Connector Pin Assignment
The pins from A1 to A6 and B1 to B6 cannot be used for the Multi-Converter for FANUC CNC.
Signal Signal
Pin Arrangement Group Pin Group Pin
Name Name
A1 V0+ B1 V0-
A2 Q1 B2 Q0
A3 V1+ B3 V1-
Unusable Unusable
A4 Q3 B4 Q2
A5 Q5 B5 Q4
A6 Q7 B6 Q6
11 / 51
The pins of C8 to C11, D8 to D11, C15, D14, and D15 cannot be used for the Multi-Converter for FANUC CNC.
Pin Arrangement Group Pin Signal Name Group Pin Signal Name
C1 I0 D1 IC0
C2 I1 D2 I2
C3 I3 D3 IC1
Standard Input C4 I5 Standard Input D4 I4
C5 I7 D5 I6
C6 I9 D6 I8
C7 I11 D7 I10
C8 MS0+ D8 MS0-
C9 EX0+ D9 EX0-
Unusable Unusable
C10 MS1+ D10 MS1-
C11 EX1+ D11 EX1-
12 / 51
3.6.2. Digital Inputs
There are 12-point digital inputs. It’s possible to switch between sink inputs and source inputs for connecting
to an external power supply. Refer to the wiring diagram below.
13 / 51
3.6.4. Serial Communication Settings
The table below shows serial communication settings of the Multi-Converter for FANUC CNC.
Baud rate 2400, 4800, 9600, 19200, 38400, 57600, 115200 4800
Timeout 1 to 127 60
Retry 0 to 255 0
14 / 51
Supported browser
・ Microsoft Internet Explorer11
Ver 11.0.****(64bit / 32bit)
・ Google Google Chrome
Ver 55.0.****(64bit / 32bit)
・ Firefox
Ver 43.0.** (64bit / 32bit)
The abovementioned versions or later are recommended.
Accessing the Multi-Converter for FANUC CNC via the Web
browser allows you to confirm setting information of the Box.
Confirming and changing settings depends on a login
authorization.
IP Address :192.168.1.80
Subnet mask :255.255.255.0
Port Number :8082
User Management Tool (Security Able to register a user name and password.
Setting) Login authorization: 3 types (Admin, Power, user)
No. of users that can be registered:
100 users per level
Target Confirmation Tool (IP The IP Address specified in the Multi-Converter for FANUC CNC
Address confirmation tool) can be confirmed.
If you forget the IP Address, confirm the IP Address with this tool.
15 / 51
4. Settings of communication with FANUC CNC
4.1. For FS16/18/21 RS-232C settings
I/O channel separation The data input channel and the data output channel
No.110#0=1
feature are separated. (recommended setting)
No.21=2
16 / 51
4.2. For FS15 RS-232C settings
17 / 51
5. MT-LINKi AdminTool
<Outline>
The following info is that how to connect with MT-LINKi and FANUC CNC Multi-Converter.
<Setting procedures>
1. Start the Admin Tool and select [Machine Setting] and then [Add Machine].
18 / 51
2. Select [OPC UA Server] for [Machine Type]. The [Select Machine] dialog box will appear.
19 / 51
3. Enter an address in the field of [Endpoint] as shown in the example below and click [Connect].
Example) Enter “opc.tcp://192.168.1.80:48010”.
This address is the same when using another client.
20 / 51
4. The Server Configuration dialog box appears.
When the OPC UA Server is correctly connected, the [Configuration options are up to date.]
message is displayed. If a different message is displayed, click [Connect] for reconnection.
When the message is different even after reconnection, the server might not run or the input
address might be different.
21 / 51
5. When connection is completed, the node names (variable names) used for the server can
be selected.
22 / 51
6. Registered variables and node names
Digital Inputs
Analog Inputs
NO, Node name (variable name) Data Type Read / Write
DPRNT
NO, Node name (variable name) Data Type Read / Write DPRNT identifier
23 / 51
14 string01 String Read / Write SR01*
24 / 51
7. Tool
7.1. Target Confirmation Tool (IP Address confirmation tool)
<Outline>
This is a tool for confirming an IP Address of the Multi-Converter for FANUC CNC.
<Use>
・ Confirming an IP Address of Multi-Converter for FANUC CNC
(Note) This tool is only for confirming an IP Address.
<How to connect>
Multi-Data Box for FANUC CNC Target Confirmation Tool
(IP Address confirmation tool)
USB Cable
25 / 51
When the USB cable is not correctly connected,
<Menu Screen>
Target Settings Select how to connect to the Multi-Converter for FANUC CNC.
Connected Status
Target Information Display device information of the connected Multi-Converter for FANUC CNC.
26 / 51
7.2. User Management Tool (Security Setting)
<Outline>
This is a tool for registering users who can log in the Multi-Converter for FANUC CNC on a Web browser.
(Note) Microsoft .NET Framework 4.5.2 or later is required for installation.
<Use>
・ Changing a user name
・ Changing a password
・ Changing a security level
<Authorization Feature>
It’s possible to configure authorization settings using 3 levels. Things that can be done differ depending on an
authorization.
1. Admin (administrators)
Able to change all the setting items. Able to change setting contents including the user
management (security).
[Default]
User Name: Admin
Password: Pro-face20
3. User (users)
Unable to change settings. Able to monitor I/O status only.
[Default] None
27 / 51
Start ‘UserManagementTool.exe’, and the following tool will start.
<Setting Procedure>
1. Export the setting contents from the Multi-Converter for FANUC CNC on the Web browser. (8.13. User
Management (Security Settings))
2. Start this tool and click [Open]. Select the user management data (security data) that has been
exported at the step, 1.
3. The Key input window box appears. If you have configured the Key setting at the time of export on the
Web browser, enter the specified Key. (8.13. User Management (Security Settings))
When no Key has been specified yet, click [OK].
4. The registered users and passwords appear.
5. Register and change [User Name], [Password], and [Group Name].
6. Click [Save].
7. Save the user management data (security data) in a USB storage and insert the USB storage to the USB
port of the Multi-Converter for FANUC CNC.
User management data storage: [USB root]¥UserManagement¥data.bin
8. If you update the user management data (security data) via the WEB browser, you can rewrite it to the
specified user management data (security data).
(Note)
If user management data (security data) is exported on a display unit, a file can be created.
When adding a user or changing a password, be sure to export the setting contents from the display unit with
using the [User Management] menu on the Web browser and edit them from the exported file using this tool.
28 / 51
Item Name Description
Register a password.
No. of characters that can be input: 8 or more characters
Characters that can be input: One-byte alphanumerical characters and symbols
Password
*Must contain at least one uppercase letter, one lowercase letter, one number,
and one symbol.
Group Name Choose among security levels, [Admin], [Power], and [user].
Last Update Display the latest date of import from the display unit.
29 / 51
8. Web Browser
<Outline>
Connecting the Multi-Converter for FANUC CNC to a PC on an Ethernet network, you can confirm or change
the settings of the main unit and execute the setting contents on a Web browser.
<Use>
・ Confirm and change setting information.
・ Confirm and change date/time settings.
・ Confirm and change time adjustment and summer time adjustment.
・ Confirm and change Ethernet settings.
・ Confirm and change OPC UA Server settings.
・ Confirm and change RS232C communication settings.
・ Transfer project files.
・ Confirm system error logs.
・ Confirm and change analog inputs.
・ Confirm and change digital inputs.
・ Security settings
Ex. http://192.168.1.80:8082
3. Entering the user name and password registered in the User Management Tool allows you to check
status of the main unit settings of the Multi-Converter for FANUC CNC.
30 / 51
8.1. Login Screen
1. Admin (administrators)
Able to change all the settings. Able to change the user management (security).
The default values for a login user name and a password are as follows;
Username: Admin
Password: Pro-face20
Up to 100 users can be registered for Admin only.
31 / 51
2. Power (power users)
Able to change settings other than the user management (security).
The default values for a login user name and a password have not been registered.
Up to 100 users can be registered for Power only.
3. User (users)
Able to only check status. Unable to change any settings.
The default values for a login user name and a password have not been registered.
Up to 100 users can be registered for User only.
32 / 51
8.2. Initial Screen
33 / 51
8.3. General (Setting information)
<Outline>
The setting contents of the currently specified IP Address or communication driver can be checked.
This screen is for monitoring only. There’s no place for setting changes.
Version Display the version of the product installed in the main unit.
34 / 51
8.4. Date / Time (Date and Time Settings)
<Outline>
The date and time of the Multi-Converter for FANUC CNC can be changed.
Click the [Save] button to reflect the setting contents. It’s not necessary to log in again after settings are
changed.
(Note) The correct time is not set at the time of shipping from the factory. Be sure to set a time.
35 / 51
8.5. Time Adjustment(Time and Summer Time)
<Outline>
Time (Time and Summer Time) of the Multi-Converter for FANUC CNC can be adjusted.
Click the [Save] button to reflect the setting contents. It’s not necessary to log in again after settings
are changed.
Choose among [None], [Rule] and [Date] for a method of configuring a period
of the summer time.
・ None: Selected when the Time Adjustment feature is not used.
Type
・ Rule: Able to adjust the start and end of the summer time choosing among
the 1st to the 5th week, a day of the week, and time as you like.
・ Date: Able to adjust the start and end of the summer time choosing among
a calendar of January to December and time.
Set a day when adding the adjustment time is executed. (On the start day of
Add Date(Rule)
the summer time).
36 / 51
Set a time when adding the adjustment time is executed. (At the start time of
Add Time
the summer time)
Set a day when subtracting the adjustment time is executed. (On the end day
Subtract Date(Rule)
of the summer time)
Set a time when subtracting the adjustment time is executed. (At the end time
Subtract Time
of the summer time)
Amount of Time for addition or subtraction to or from the start/end time of the summer
Time(Minutes) time. (-120 to 120 minutes)
37 / 51
Authorization at the time of login
・ Admin (administrators): Able to change settings.
・ Power (power users): Able to change settings.
・ User (users): Unable to change settings. Unable to see settings.
Click the [Save and Reboot] button to reflect the setting contents.
Because of reboot, it’s necessary to log in again after settings are changed.
38 / 51
8.7. OPC UA Server Settings
<Outline>
The OPC UA Server settings of the Multi-Converter for FANUC CNC can be configured.
Click the [Save and Reboot] button to reflect the setting contents.
Because of reboot, it’s necessary to log in again after settings are changed.
39 / 51
8.8. Drivers (RS-232C communication setting)
<Outline>
The serial port settings of the Multi-Converter for FANUC CNC can be configured.
This will become information of FANUC DPRNT SIO communication setting. Configure the same
communication setting as that of FANUC CNC for the items below.
Click the [Save and Reboot] button to reflect the setting contents.
Because of reboot, it’s necessary to log in again after settings are changed.
40 / 51
Item Name Description
41 / 51
Item Name Description
Transfer the version upgrade file in USB storage to the Multi-Converter for
Download From USB
FANUC CNC. When transfer starts, log out from Configuration.
Eject USB Remove USB storage safely.
(Note)
・ Save the version upgrade file (package.BML) to the root directory of USB storage.
・ When transfering the project, User Management data (Security Settings), OPC UA Server Settings, and
Drivers settings are initialized. Back up (Export) the user management data before transferring. (8.13.
User Management (Security Settings))
<Update Procedure>
1. Click the Download From USB button.
2. A message is displayed. Confirm the contents and click OK to start transferring.
Once transfer starts, logout from Configuration is done automatically.
6. Import the backed up user management data. (8.13. User Management (Security Settings))
If necessary, set up the OPC UA Server settings and Drivers again.
42 / 51
8.10. System Log (System Error Log)
<Outline>
The system logs of the Multi-Converter for FANUC CNC can be confirmed.
This screen is for monitoring only. There’s no place for settings. The latest error contents are displayed on top.
Message A system error, a communication error code, and an error message are displayed.
43 / 51
8.11. Analog Input
<Outline>
This is an analog input screen of the Multi-Converter for FANUC CNC.
44 / 51
Item Name Description
Displays numerical values of input data. The numerical values change in the
range described below.
・0 to 10V: The data values change in the range of 0 to 8191.
Input Data
・-10V to 10V: The data values change in the range of -4096 to 4095.
・0 to 20mA: The data values change in the range of 0 to 8191.
・4 to 20mA: The data values change in the range of 0 to 8191.
Low Pass Filter Choose among [None], [Low], [Standard], and [High] for Low Pass Filter.
(Supplementary)
Only when ‘4 to 20mA’ is selected, disconnection of input signals can be detected.
When the analog value is 65535, input signals are disconnected.
When you log in with the User authorization, the following screen appears.
No settings related to analog can be changed.
45 / 51
8.12. Digital Input
<Outline>
Digital inputs of the Multi-Converter for FANUC CNC can be monitored.
46 / 51
8.13. User Management (Security Settings)
<Outline>
User management (security) settings of the Multi-Converter for FANUC CNC can be configured.
Transfer user management data (security data) from the Multi-Converter for
FANUC CNC to a USB storage.
When exporting the data from the main unit, the key input window appears.
Export If you have configured the key setting at the time of import, enter the
specified key. If not, just click [OK]. If a key has been entered, it will be
needed at the time of import and using the User Management Tool.
Storage of user management data: [USB root]¥UserManagement¥data.bin
47 / 51
9. Compatibility with the related products
■Version Upgrade File
The file provided at version upgrade is for the Multi-Converter for FANUC CNC only. It cannot be used for other
models.
・ Because user management data (security data) is for the Multi-Converter for FANUC CNC only, it
cannot be used for other models.
・ For user management data (security data), only the file exported from the Multi-Converter for
FANUC CNC unit can be imported.
■USB Storage (storage device)
10. Restrictions
・ The day and time is not set at the time of purchase. Be sure to set it.
・ If you transfer data with Transfer (Project Transfer) at the time of version upgrade, the user
management data (security data) will be Initialized. Log in with the default value after transfer is
completed. (User Name: Admin, Password: Pro-face20).
・ Be sure to back up the user management data (security data) before transfer work is done.
48 / 51
11. Error Code List
Error Code Message Cause Solution
There’s no
Turn off the power of the display unit
The equipment is not communication made
APP10511 and then check the cabling and the
connected. between the display unit
connector’s wiring.
and the connected device.
49 / 51
Follow either one of the instructions
below.
The system version (%s) The runtime version of the 1. Downgrade the runtime version on
is lower than current project file in the external the display unit to the same
SYS00008
system version (%s), storage is lower than the version as that of the project file.
during the %s process. one on the display unit. 2. Download the project file with the
same version as the one of the
runtime.
In the process of
transferring the project
Restore of %s from the
file to the display unit Restart the display unit and transfer
SYS00011 backup file failed during
using the external the data again.
the %s process.
storage, writing the data
failed.
In the process of
Extraction of %s archive
transferring the project Restart the display unit and transfer
SYS00012 failed during the %s
file to the display unit, the data again.
process.
writing the data failed.
Lack of the free space of Confirm that the free space of the
%s archive creation failed the external storage or external storage and the hard disk is
SYS00015
during the %s process. the hard disk. Or it cannot enough, the mode is not ‘Read Only’
be accessed. and you have an access right.
Charge the backup The battery will run out in Recharge the battery completely for
SYS02001
battery. a few weeks. a few days.
SYS02002 Replace the backup The battery will run out in Do not replace the battery yourself.
50 / 51
battery. a few days. Contact your local Pro-face
distributor for replacing the battery
before the battery runs out.
51 / 51