# Demo lfn file

Global Constants

"# TStd defines the temperature at which ""Standard Volume Units"" are defined in
the units used in the sheet (This defines the temperature units used in this
sheet)"

TStd 60 degF

# Tabs defines the value to add to the temperatures used in the sheet to get to
absolute temperature

Tabs 460 deg

"# PStd is the pressure of ""Standard"" volume units in the pressure units used
throughout this sheet (This defines the pressure units used in this sheet)"

PStd 0 psig

# Pabs is the value to add to the pressures used in this sheet to get to absolute
pressure

Pabs 14.7 psi

#These next two just put the EU=; section in the description of the tags. They are
not used for any calculations

PressEU psia

FlowEU BPH

Pump Curves Performance Efficiency

$END

Level Tag Design P EUHi RawHi

LT_V02124 S_P_V02124_LFN 10000

LT_T02103 S_P_T02103_LFN 5000

LT_V02112 S_P_V02112_LFN 10000

LT_V50 S_P_V50_LFN 5000

LT_H02104 Stm_P_H02104_LFN 1000

LT_H02103 Stm_P_H02103_LFN 1000

LT_V02302 S_P_V02302_LFN 1000


LT_V02301_Top S_P_V02301_Top

LT_V02301_Bttm S_P_V02301_Bttm 1000

LR23502_Sim S_P23502

LI23521_Sim S_P23521

$END

Pressure Node Design Pressure scale factor EULo EUHi RhogH

S_P_Plant3 20

S_P_Plant5 20

S_P_V02124_LFN 15

S_P02101Disch 100

S_LFN_Boundary1 90

S_P_Frac_Tray25 45

S_P_Frac_Tray23 44

S_P02115Disch 75

S_P_Riser 25

S_P02116Disch 100

S_P_Mixing2 50

S_P_PLT3 25

S_P_Frac_Tray12 39

S_P02113Disch 75

S_P_Frac_Tray10 38

S_P_T02103_LFN 25

S_P02112Disch 75

S_P_LCO 25

S_P_Frac_Tray16 42
S_P02114Disch 75

S_P_Frac_Tray18 43

S_P_HotBelt 25

S_P_Frac_Tray14 41

S_P_Frac_Tray4 37

S_P02111Disch 75

S_P_E02117_Upstream 60

S_P_E02117_Dwnstream 50

S_P_Frac_Tray2 36

S_P02106Disch 75

S_P_V02112_LFN 29.4

S_P_V50_LFN 17

S_P_Cond_l 20

S_P_Water 20

S_P23Disch 735

S_P_PLT3Cond 600

S_P_Economizer 590

Stm_P_H02104_LFN 560

Stm_P_H02103_LFN 560

S_P_Bldwn 200

S_P_Ammonia 20

S_P_V02302_LFN 15

S_P02301Disch 95

S_P_E02301_LFN 45

S_P_CityWater 20

S_P02310Disch 75

S_P_Caustic 60

S_P_V02301_Top 47

S_P02303Disch 128

S_P_V02301_Bttm 30
S_P_FireWater 60

S_P02302Disch 40

S_PI21654 590

S_P23502 35

S_P02307Disch 50

S_P23521 29

S_P_Eff 15

S_P_E02104A_LFN 465

S_P_E02104B_LFN 465

S_P_E02104C_LFN 465

S_P_BOC 15

S_P_PLT3_SRU 50

S_P_E02145 600

S_P_V424_LFN 15

$END

Flow Tag Valve Tag UpStream P DownStrm P DesignValvePos FlowThruVlv


RatedFlow RatedDP Pump Curve Conditions DecPlaces

#RXTR_FD

Flow_Fresh_Feed1 S_Valve_Feed1 S_P_Plant3 LT_V02124 50 1510

Flow_Fresh_Feed2 S_Valve_Feed2 S_P_Plant5 LT_V02124 50 1510

Flow_P02101A Pump_P02101A_Speed LT_V02124 S_P02101Disch 50 3020


Pump_P02101A
Flow_P02101B Pump_P02101B_Speed LT_V02124 S_P02101Disch 50
3020 Pump_P02101B
Flow_Feed_Bypass S_FZS21002 S_P02101Disch LT_V02124 50 3020

Flow_Feed_FracTower S_HX21001 S_P02101Disch S_P_Frac_Tray23 50


3020
Flow_FI21001 S_FX21001 S_P02101Disch S_LFN_Boundary1 50 3020

#FRACT_T01

Flow_P02115A_Bttms Pump_P02115A_Speed S_P_Frac_Tray25 S_P02115Disch


50 5312 "Pump_P02115A,(LI21153.pve > 1)"
Flow_P02115B_Bttms Pump_P02115B_Speed S_P_Frac_Tray25 S_P02115Disch
50 5312 "Pump_P02115B,(LI21153.pve > 1)"

Flow_E02104_Recycle S_P02115Disch S_P_Frac_Tray23 50 5152

Flow_Riser_Recycle S_RiserValve S_P02115Disch S_P_Riser 50


160
Flow_P02116A Pump_P02116A_Speed S_P02115Disch S_P02116Disch 50
160 Pump_P02116A
Flow_P02116B Pump_P02116B_Speed S_P02115Disch S_P02116Disch 50
160 Pump_P02116B
Flow_E02115 S_P02116Disch S_P_Mixing2 50 160
S_E15_Main
Flow_E02115_Bypass S_E15_Bypass S_P02116Disch S_P_Mixing2 50 160

Flow_FI21206 S_FX21206 S_P_Mixing2 S_P_PLT3 50 160

Flow_Tray12_LC21153 S_LX21153 S_P_Frac_Tray12 LT_T02103 50 788

Flow_P02112A Pump_P02112A_Speed LT_T02103 S_P02112Disch 50 788


Pump_P02112A
Flow_P02112B Pump_P02112B_Speed LT_T02103 S_P02112Disch 50
788 Pump_P02112B
Flow_LCO_Exit S_LX21154 S_P02112Disch S_P_LCO 50 788

Flow_Tray12_P02113 Pump_P02113_Speed S_P_Frac_Tray12 S_P02113Disch 50


2546 "Pump_P02113, HZAL21007"

Flow_FI21153 S_FX21153 S_P02113Disch S_P_Frac_Tray10 50 2546

Flow_P02114A_HCO Pump_P02114A_Speed S_P_Frac_Tray16 S_P02114Disch 50


867 "Pump_P02114A, HZAL21008"

Flow_P02114B_HCO Pump_P02114B_Speed S_P_Frac_Tray16 S_P02114Disch 50


867 "Pump_P02114B, HZAL21008"
Flow_FR21154_SplBck S_LX21151 S_P02114Disch S_P_Frac_Tray18 50
870
Flow_HCO_Bleed S_P02114Disch S_P_HotBelt 50 50

Flow_FI21151_HCO S_FX21151 S_P02114Disch S_P_Frac_Tray14 50 817

Flow_P02106A Pump_P02106A_Speed LT_V02112 S_P02106Disch 50 1714


Pump_P02106A
Flow_P02106B Pump_P02106B_Speed LT_V02112 S_P02106Disch 50
1714 Pump_P02106B
Flow_FR21167 S_LX21161 S_P02106Disch S_P_V424_LFN 50 1468

Flow_FR21156 S_TX21155 S_P02106Disch S_P_Frac_Tray2 50 246

Flow_P02111A Pump_P02111A_Speed S_P_Frac_Tray4 S_P02111Disch 50


3200 "Pump_P02111A, (T2101_N21.pve > 0.01)"

Flow_P02111B Pump_P02111B_Speed S_P_Frac_Tray4 S_P02111Disch 50


3200 "Pump_P02111B, (T2101_N21.pve > 0.01)"

Flow_E02145_Bypass S_E45_Bypass S_P02111Disch S_P_E02117_Upstream


50 3200
Flow_E02145 S_P02111Disch S_P_E02117_Upstream 50 3200
Flow_E02117 S_P_E02117_Upstream S_P_E02117_Dwnstream 50 3200

Flow_E02117_Bypass S_E17_Bypass S_P_E02117_Upstream


S_P_E02117_Dwnstream 50 3200

Flow_FI21160 S_FX21160 S_P_E02117_Dwnstream S_P_Frac_Tray2 50 3200

#H04/H03_CO_Boilers

Flow_FR21651_Water S_P_Cond_l LT_V50 50 400

Flow_FR21601_Water S_LX21611 S_P_Water LT_V50 50 1680

Flow_V50_Liq LT_V50 50 159.75

Flow_BOC_Water LT_V50 S_P_BOC 50 39.75

Flow_P23A Pump_P23A_Speed LT_V50 S_P23Disch 50 2200


Pump_P23A
Flow_P23B Pump_P23B_Speed LT_V50 S_P23Disch 50 2200
Pump_P23B
Flow_FI21559_BFW S_FX21559B S_P23Disch LT_H02104 10 30

Flow_FI21509_BFW S_FX21509B S_P23Disch LT_H02103 10 30

Flow_PC21654_BFW S_PX21654 S_P23Disch S_PI21654 50 2140

Flow_SRU_BFW S_PI21654 S_P_PLT3_SRU 50 1482

Flow_FR21210_BFW S_LR21201A S_PI21654 S_P_E02104A_LFN 50 233

Flow_FR21211_BFW S_LR21203A S_PI21654 S_P_E02104B_LFN 50 239

Flow_FR21212_BFW S_LR21205A S_PI21654 S_P_E02104C_LFN 50 186

Flow_Economizer_Water S_P_E02145 S_P_Economizer 50 1316

Flow_FI21559A_Eco S_FX21559A S_P_Economizer LT_H02104 50 644

Flow_FI21509A_Eco S_FX21509A S_P_Economizer LT_H02103 50 672

Flow_H02104_Stm LT_H02104 50 664.5363

Flow_H02103_Stm LT_H02103 50 669.1583

Flow_H02104_Bldwn S_H02104_Bldwn LT_H02104 S_P_Bldwn 10 9.4637

Flow_H02103_Bldwn S_H02103_Bldwn LT_H02103 S_P_Bldwn 10 32.8417

#SCR_System

Flow_Ammonia_V02302 S_Ammonia_V02302 S_P_Ammonia LT_V02302 50 32.64

Flow_P02301A_Ammonia Pump_P02301A_Speed LT_V02302 S_P02301Disch 50


32.64 Pump_P02301A
Flow_P02301B_Ammonia Pump_P02301B_Speed LT_V02302 S_P02301Disch 50
32.64 Pump_P02301B
Flow_FI23025_Ammonia S_FX23025 S_P02301Disch S_P_E02301_LFN 50 32.64
#WGS_System

Flow_P02310A_Water S_P_CityWater S_P02310Disch 50 314


NL23431
Flow_P02310B_Water S_P_CityWater S_P02310Disch 50 314
NL23432
Flow_FI23403_Water S_FX23403 S_P02310Disch LT_V02301_Top 50 314

Flow_FI23401_Caustic S_FX23401 S_P_Caustic LT_V02301_Top 50 2.15

Flow_P02303A_Soln LT_V02301_Top S_P02303Disch 50 125


NL23415
Flow_P02303B_Soln LT_V02301_Top S_P02303Disch 50 125
NL23416
Flow_TopRecirc_Soln S_TopRecirc S_P02303Disch LT_V02301_Top 50
125
Flow_To_Bottom LT_V02301_Top 50 316.15

Flow_From_Top LT_V02301_Bttm 50 316.15

Flow_FireWaterA S_P_FireWater LT_V02301_Bttm 50 100


TV23401A
Flow_FireWaterB S_P_FireWater LT_V02301_Bttm 50 100
TV23401B
Flow_FI23402_Caustic S_FX23402 S_P_Caustic LT_V02301_Bttm 50 24

Flow_P02302A_Soln LT_V02301_Bttm S_P02302Disch 50 340.15


NL23413
Flow_P02302B_Soln LT_V02301_Bttm S_P02302Disch 50 340.15
NL23414
Flow_BtmRecirc_Soln S_BttmRecirc S_P02302Disch LT_V02301_Bttm 50
340.15
Flow_FI23411_Purge S_FX23411 S_P02302Disch LR23502_Sim 50 340.15

#PTU_System

Flow_M02301_Purge LR23502_Sim 50 340.15

Flow_TK02_In LI23521_Sim 50 340.15

Flow_FI23511_Caustic S_FX23511 S_P_Caustic LI23521_Sim 50 3

Flow_FI23512_Caustic S_FX23512 S_P_Caustic LI23521_Sim 50 3

Flow_FI23513_Caustic S_FX23513 S_P_Caustic LI23521_Sim 50 3

Flow_P02307A_Eff LI23521_Sim S_P02307Disch 50 343.15


NL23521
Flow_P02307B_Eff LI23521_Sim S_P02307Disch 50 343.15
NL23522
Flow_FR23524_Eff S_LX23521 S_P02307Disch S_P_Eff 50 343.15

$END
Tagname Driver FullAddress Description Type Value DecPlaces Mode
CycleTime EULo EUHi RawLo RawHi IOChar Algorithm Params
$END