Manómetro M
Manómetro M
Manómetro M
• Available in 41⁄2˝ and 6˝ dial sizes Ashcroft® bellows gauges are used
for measuring low pressures from
• Bellows-actuated mechanism
10˝ H2O to 10 psi pressure as well
• Three bellows materials as vacuum and compound ranges.
Coupled with their sensitivity, these
• Easily adjustable micrometer gauges have a rugged design for
pointer
process and industrial applications.
• Phenolic (1188) or aluminum
(1187, 1189) cases
• All-stainless steel movements
Pressure Ranges(2,4)
STANDARD METRIC
Single Dual Single Dual
Scale Dial Scale Dial Scale Dial Scale Dial
CASE Selection
Compound Pressure Pressure Pressure
(Vac/Press) Inner Outer Outer Scale Dial Size(1) Case Type Case Material Ring Style Mounting
in.H2O in.H2O oz/in2 mmH2O in.H20 Aluminum, black Hinged steel,
4 ⁄2˝
1
1187 Flush — back only
–5/5 0/10 0/6 0/250 0/10 epoxy coated black crinkle enamel
–10/10 0/15 0/9 0/400 0/16 Stem — lower or back
–30/10 0/20 0/12 0/600 0/24 Threaded polypropylene Surface — lower or back
–20/20 0/30 0/18 41⁄2˝ 1188 Phenolic, black
0/1000 0/40 ring Flush— back, order 1278M
–40/20 0/40 0/24 0/1600 0/60 mounting ring, specify X56
–10/30 0/60 0/35 0/2500 0/100
–30/30 0/80 0/45 Aluminum, Threaded polypropylene Stem — lower
0/4000 0/160 41⁄2˝, 6˝ 1189
–70/30 0/100 0/57 black epoxy coated ring Surface — lower
0/6000 0/240
–20/40 0/150 0/90
–50/50 Vacuum Vacuum
in.Hg/psi psi in.Hg –250/0 –10/0
–5/3 0/5 0/10 –400/0 –16/0 BELLOWS System/RANGE Selection(1)
–2/5 0/8 0/16 –600/0 –24/0 Order Bellows Pressure Vacuum Compound NPT Available
–5/5 0/10 0/20 –1000/0 –40/0 Code & Socket Range Range Range Conn. Case Size
–10/5 –1600/0 –60/0 Material and Type
Vacuum –2500/0 –100/0 5 in.H2O vac. & 5 in. 41⁄2˝–1187
in.H20 mmHg –4000/0 –160/0 10 in.H2O to
A Brass 10 in.H2O to 10 psi 5 in.H2O vac. & 10 in. 1
⁄4, 1⁄2 41⁄2˝–1188
10/0 18/0 –6000/0 –240/0 20 in.Hg
Hg vac. & 5 psi 41⁄2˝, 6˝–1189(3)
15/0 28/0 Compound Compound
20/0 37/0 5 in.H2O vac. & 5 in. 41⁄2˝–1187
10˝ H2O to
30/0 56/0 –125/125 –5/5 S 316 SS 10 in.H2O to 10 psi 5 in.H2O vac. & 10 in. 1
⁄4, 1⁄2 41⁄2˝–1188
20 in.Hg
40/0 75/0 –200/200 –8/8 Hg vac. & 5 psi 41⁄2˝, 6˝–1189(3)
60/0 110/0 –300/300 –12/12 5 in.H2O vac. & 5 in. 41⁄2˝–1187
–500/500 –20/20 10˝ H2O to
80/0 150/0 P Monel 10 in.H2O to 10 psi 5 in.H2O vac. & 10 in. 1
⁄4, 1⁄2 41⁄2˝–1188
20 in.Hg
100/0 180/0 –800/800 –30/30 Hg vac. & 5 psi 41⁄2˝, 6˝–1189(3)
150/0 270/0 –1250/1250 –50/50
–2000/2000 –80/80 (1) For selection of the correct bellows system material, see the
in.Hg ftH20 media application table on page 253 or the Corrosion Guide.
–3000/3000 –120/120 (2) Others ranges available: Consult factory.
10/0 11/0
15/0 17/0 (3) Lower connect only.
(4) Dual scale standard. If single scale is required, specify
20/0 23/0 “single scale only.”