SPECIFICATION SHEET FOR AIR RECEIVER

Application Air receiver ok


Equipment Detail Cylindrical Shell with dish bottom & Top ok
Code of Design and Construction ASME Sec VIII Div 1, Edition 2015 ok
ASME Certification Requirement Depnaker certificate with ASME design Depnaker certificate with ASME d
Country of Installation INDONESIA ok
Location of Installation KIJING WEST KALIMANTAN
Diameter of Shell (OD) 1820 mm
Shell Thickness 10 mm
Type Cylinder
Orientation Vertical
Service fluid Instrument Air (Moisture free)
Fluid density 1.2 Kg/m3 @ 30 Deg C
Corrosion allowance 3 mm
Volume of Tank 10.000 L
No of Tanks ???
Tank elevation GROUND LEVEL + FOUNDATION
Design Conditions
Operating pressure 8 kg/cm2 (g)
Operating temperature 45 Deg C
Internal Design Pressure 15 bar (g)
MAWP 10 bar(g)
Safety valve set pressure 10 bar(g)
External Pressure NA
Cyclic Operation NIL
Design Temperature 60 deg C
MDMT (Vessel and structures) 0 deg C
Wind Loading
Seismic Loadings
Radiography RT 2 - Long seam – Full, Circ Seam – Spot
Joint Efficiency As per UW -12
Shell = 1.0, Dish = 1.0
Loadings – UG -22 Pipe Support, Hydro Test.
Hydro test pressure 15 bar (g)
PWHT As per code (Not required)
Post Forming Heat Treatment (PFHT) As per code (Not required)
Internals Nil (Except Ladder for Manhole)
Others Ladder & Platform with railing not required
Insulation Nil
Fire Proofing No
Snow loading No
Lifting Lugs Yes – 2 Nos (At top dish ends)
Diameter of Shell (ID)
TL to TL length
Shell Thickness
Dish Ends types
Support type
Leg pipe
Base plate dimensions
Earthing lug
Approximate overall length of the vessel
Lifting lug
Surface preparation
Painting
Inside ladder
Ladder (Structural) & Platform
NOZZLE SCHDULE
Nozzzle GROUND LEVEL + FOUNDATION Qty
No (Nos)
NZ Nozzle Vertical

NZ 8 kg/cm2 (g)

NZ 45 Deg C

NZ

NZ

MH 01

CODES TO BE FOLLOWED
DESIGN AND FABRICATION ASME Boiler and Pressure vessel Code
SEC VIII, Div 1, Edition 2015
MATERIALS 8 kg/cm2 (g)
WELDING RODS 45 Deg C
WELDING QUALIFICATION
NON DESTRUCTIVE EXAMINATION
FLANGES
PIPES ASME B 36.10
FITTINGS ASME B 16.11
NOZZLE LOADINGS
WIND LOADING
SEISMIC LOADING
PAINTING
Documents to be submitted after release of official PO
1. Design of Air receiver. 3 Copies in English Language
2. Drawings for Approval.
3. Inspection and Test plan.
4. PQR ,and WPS for Approval.

HYDRO TEST REPORT as depnaker certificate


RT REPORT
SAFETY VALVE CALIBRATION 10 bar(g)
DEPNAKAR
PRESSURE SWITCH not include ( pressure gauge yes)
PRICE EXCLUDE PPN
DELIVERY TO KIJING
INSTALLATION
TRAINING
PAYMENT TERMS
ADVANCE 30%
DELIVERY TO KIJING 55%
INSTALLATION 5%
COMMISSIONING 5%
WARRANTY 1 YEAR FROM COMMISSIONING OR 18 MONTHS AFTER DESPATCH
RETENTION 5% 6 MONTHS
Depnaker certificate with ASME design

1800 mm

10 mm
2:1 Ellipsoidal
Leg type with pipes (4 Nos)

260 x 320 x 14 mm
diameter 16 mm
4630 mm
14 mm
Inside – 2 Coats of red oxide zinc chromate primer. (2.5 mil) Outside – 2
Coats of chlorinated rubber paint
In the scope of client (If needed)
SCHDULE
Size Flange Class (or) OTHERS
Type Series
SORF, -
B 16.5
SORF, -
B 16.5
SORF, -
B 16.5
SORF, -
B 16.5
Half Coupling -
B 16.11
SORF, B 16.5 R.F pad of -------mm
OD, 8 Thk
With Davit Arm
Mechanism