c220m7 SFF Specsheet
c220m7 SFF Specsheet
c220m7 SFF Specsheet
OVERVIEW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
DETAILED VIEWS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Detailed Chassis Front View . . .... ... .... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Detailed Chassis Rear Views . . .... ... .... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
One Half-Height Riser . . .... ... .... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Three Half-Height Risers .... ... .... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Two Full-Height Risers . .... ... .... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
BASE SERVER STANDARD CAPABILITIES and FEATURES . . . . . . . . . . . . . . . . 10
CONFIGURING the SERVER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
STEP 1 SELECT SERVER SKU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
STEP 2 SELECT RISERS (REQUIRED) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
STEP 3 SELECT CPU(s) (REQUIRED) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
STEP 4 SELECT MEMORY (REQUIRED) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Memory configurations and mixing rules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
STEP 5 SELECT DRIVE CONTROLLERS (OPTIONAL) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
RAID Volumes and Groups . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
STEP 6 SELECT DRIVES (OPTIONAL) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
STEP 7 SELECT OPTION CARD(s) (OPTIONAL) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
ORDER OPTIONAL PCIe OPTION CARD ACCESSORIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
STEP 8 ORDER GPU CARDS (OPTIONAL) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
STEP 9 ORDER POWER SUPPLY (REQUIRED) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
STEP 10 SELECT INPUT POWER CORD(s) (REQUIRED) . . . . . . . . . . . . . . . . . . . . . . . . . . 43
STEP 11 ORDER TOOL-LESS RAIL KIT (REQUIRED) AND REVERSIBLE CABLE MANAGEMENT ARM (OPTIONAL)
47
STEP 12 SELECT MANAGEMENT CONFIGURATION (OPTIONAL) . . . . . . . . . . . . . . . . . . . . 48
STEP 13 ORDER SECURITY DEVICES (REQUIRED) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
STEP 14 SELECT LOCKING SECURITY BEZEL (OPTIONAL) . . . . . . . . . . . . . . . . . . . . . . . . 50
STEP 15 ORDER M.2 SATA SSDs (OPTIONAL) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
STEP 16 ORDER M.2 NVMe AND RAID CONTROLLER(OPTIONAL) . . . . . . . . . . . . . . . . . . . . 52
STEP 17 SELECT OPERATING SYSTEM AND VALUE-ADDED SOFTWARE . . . . . . . . . . . . . . . . 53
STEP 18 CHOOSE OPTIONAL OPERATING SYSTEM MEDIA KIT . . . . . . . . . . . . . . . . . . . . . . 57
SUPPLEMENTAL MATERIAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
Block Diagrams . . . .... ... .... ... .... .... ... .... ... .... .... ... .... . . 58
Chassis . . . . . . . . . .... ... .... ... .... .... ... .... ... .... .... ... .... . . 60
Risers . . . . . . . . . .... ... .... ... .... .... ... .... ... .... .... ... .... . . 62
Serial Port Details . .... ... .... ... .... .... ... .... ... .... .... ... .... . . 65
KVM Cable . . . . . . .... ... .... ... .... .... ... .... ... .... .... ... .... . . 65
UPGRADING or REPLACING CPUs and Memory . . . . . . . . . . . . . . . . . . . . . . 66
SPARE PARTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
TECHNICAL SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80
Dimensions and Weight . . . . . . . . . . . . . . . . . . . . . . . .... ... .... .... ... .... . . 80
Power Specifications . . . . . . . . . . . . . . . . . . . . . . . . .... ... .... .... ... .... . . 81
Environmental Specifications . . . . . . . . . . . . . . . . . . . .... ... .... .... ... .... . . 86
Compliance Requirements . . . . . . . . . . . . . . . . . . . . . .... ... .... .... ... .... . . 87
DISCONTINUED EOL PRODUCTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88
1 Cisco UCS C220 M7 Rack Server (Small Factor Disk Drive Model)
OVERVIEW
OVERVIEW
The Cisco UCS C220 M7 SFF server extends the capabilities of Cisco’s Unified Computing System portfolio in
a 1U form factor with the 5th Gen. Intel® Xeon® Scalable Processors, 16 DIMM slots per CPU for DDR5-5600
Memory DIMMs with DIMM capacity points up to 128GB or 4th Gen. Intel® Xeon® Scalable Processors, 16 DIMM
slots per CPU for DDR5-4800 Memory DIMMs with DIMM capacity points up to 128GB.
The Cisco UCS C220 M7 server harnesses the power of the latest Intel® Xeon® Scalable Processors and offers
the following:
CPU:
■ Up to 2x 5th Generation Intel® Xeon® Scalable Processors with up to 60 cores per processor or
■ Up to 2x 4th Generation Intel® Xeon® Scalable Processors with up to 52 cores per processor.
Memory:
■ Up to 4TB with 32 x 128GB DDR5-5600 DIMMs, in a 2-socket configuration with 5th Gen. Intel® Xeon®
Scalable Processors or
■ Up to 4TB with 32 x 128GB DDR5-4800 DIMMs, in a 2-socket configuration with 4th Gen. Intel® Xeon®
Scalable Processors.
mLOM: The UCS C220 M7 SFF server has a single 1GBE management port. A modular LAN on motherboard
(mLOM)/OCP 3.0 module provides up to two 100GBE ports. A connector on the front of the chassis provides
KVM functionality.
The Cisco UCS C220 M7 SFF server can be used standalone, or as part of the Cisco Unified Computing
System, which unifies computing, networking, management, virtualization, and storage access into a single
integrated architecture, enabling end-to-end server visibility, management, and control in both bare metal
and virtualized environments.
See Figure 1 on page 3 for front and rear views of the UCS C220 M7 server.
Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model) 2
OVERVIEW
Front View
Rear View (two full-height riser card version - shown with riser blanks installed)
3 Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model)
DETAILED VIEWS
DETAILED VIEWS
Detailed Chassis Front View
Figure 2 shows the detailed front view of the Cisco UCS C220 M7 SFF Rack Server
14 Unit Identification button/LED 20 KVM connector (used with KVM cable that
provides two USB 2.0, one VGA, and one
serial connector)
Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model) 4
DETAILED VIEWS
Notes:
1. You can mix and match in drive bays 1 - 4. For example, slots 1 and 2 can hold NVMe drives and slots 3 and 4
can hold SAS/SATA HDDs or SSDs.
2. If using a SATA Interposer board, up to a maximum of 8 SATA-only drives can be configured (slots 1-4 and 6-9
only)
Figure 4 shows the details of the rear panel for the UCS C220 M7 with three rear half-height PCIe risers.
Figure 5 shows the details of the rear panel for the UCS C220 M7 with two rear full-height PCIe risers.
5 Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model)
DETAILED VIEWS
NOTE: 1-CPU servers support 1 and 2 half-height risers. 2-CPU servers support all three
half-height risers.
Figure 3 Chassis Rear View (one half-height, 3/4 length PCIe riser)
Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model) 6
DETAILED VIEWS
NOTE:
■ Only 2-CPU servers support all three half-height risers.
■ Gen4 and Gen5 risers cannot be mixed.
Figure 4 Chassis Rear View (three half-height, 3/4 length PCIe risers)
7 Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model)
DETAILED VIEWS
3 There is one half height riser 3 option: 8 COM port (RJ45 connector)
Riser 3A PCIe Gen4 x16 (CPU2 control)
■ Supports one PCIe slot (slot 3)
■ Slot 3 is half-height, 3/4 length, x16,
NCSI, Single Wide GPU
4 Power supplies (two, redundant as 1+1) 9 1GBE dedicated Ethernet management
port
5 Modular LAN on motherboard (mLOM)/OCP 10 USB 3.0 ports (two)
3.0 slot
NOTE: 1-CPU servers support only full-height riser 1 while 2-CPU servers support both full-height
risers.
Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model) 8
DETAILED VIEWS
1 Riser 1C PCIe Gen5 (CPU1 control) 6 VGA display port (DB15 connector)
■ Supports one PCIe slot (slot 1)
■ Slot 1 is full-height, 3/4 length,
x16,NCSI, Single Wide GPU
2 Riser 3C PCIe Gen5 x16 (CPU2 control) 7 COM port (RJ45 connector)
■ Supports one PCIe slot (slot 3)
■ Slot 3 is Full-height, 3/4 length, x16,
NCSI, Single Wide GPU
3 Power supplies (two, redundant as 1+1) 8 1GBE dedicated Ethernet management port
5 System ID pushbutton/LED - -
9 Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model)
BASE SERVER STANDARD CAPABILITIES and FEATURES
Capability/Feature Description
Chassis One rack unit (1RU) chassis
CPU ■ One or two 5th Gen. Intel® Xeon® Scalable Processors or One or two 4th
Gen. Intel® Xeon® Scalable Processors.
■ Each CPU has 8 channels with up to 2 DIMMs per channel, for up to 16
DIMMs per CPU
■ UPI Links: Up to 3 at 20GT/s
Chipset Intel® C741 series chipset
Memory ■ 32 total DDR5-5600 MT/s DIMM slots with 5th Gen. Intel® Xeon® Scalable
Processors (16 per CPU) or 32 total DDR5-4800 MT/s DIMM slots with 4th
Gen. Intel® Xeon® Scalable Processors
■ Up to 4TB DDR5-5600 DIMM memory capacity (32x 128GB DIMMs) with 5th
Gen. Intel® Xeon® Scalable Processors or Up to 4TB DDR5-4800 DIMM
memory capacity (32x 128GB DIMMs) with 4th Gen. Intel® Xeon® Scalable
Processors
■ Up to 75% peak bandwidth increase over DDR4-3200, with on-die ECC; all
densities are Registered DIMMs (RDIMMs)
Video The Cisco Integrated Management Controller (CIMC) provides video using the
Matrox G200e video/graphics controller:
Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model) 10
BASE SERVER STANDARD CAPABILITIES and FEATURES
Capability/Feature Description
Expansion slots ■ Half-height riser slots (select up to three)
• Riser 1A PCIe Gen4 x16 HH
• Riser 1B PCIe Gen5 x16 HH
• Riser 2A PCIe Gen4 x16 HH
• Riser 2B PCIe Gen5 x16 HH
• Riser 3A PCIe Gen4 x16 HH (CPU2 Control)
■ Full-height riser slots (select up to two)
• Riser 1C PCIe Gen5 x16 FH
• Riser 3C PCIe Gen5 x16 FH (CPU2 Control)
Interfaces ■ Rear panel
11 Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model)
BASE SERVER STANDARD CAPABILITIES and FEATURES
Capability/Feature Description
Internal storage devices Drive storage:
Drives are installed into front-panel drive bays, which provide hot-swappable
access for SAS/SATA or NVMe drives. The server is orderable in two different
versions:
■ UCSC-C220-M7S (option 1):
• Up to 10 SFF SAS/SATA hard drives (HDDs) or SAS/SATA/NVMe solid state
drives (SSDs).
• Optionally, up to four direct-attach SFF NVMe PCIe SSDs. These drives
must be placed in front drive bays 1, 2, 3, and 4 only, can be mixed
with SAS/SATA drives, and are controlled from CPU 2. The rest of the
bays (5 - 10) can be populated with SAS/SATA/NVMe SSDs or HDDs. Two
CPUs are required when choosing direct-attach NVMe SSDs.
• If using a SATA Interposer, up to 8 SATA-only drives can be installed
(slots 1-4 and 6-9 only).
■ UCSC-C220-M7N (option 2):
• Up to 10 2.5-inch direct-attach NVMe SSDs. only.
• The drives in slots 1, 2, 3, 4, 6, and 7 are connected to CPU 2 and the
drives in slots 5, 8, 9, and 10 are connected to CPU1. Up to 4 drives are
allowed with single CPU configuration and can only be installed in slots
5, 8, 9, and 10.
Other storage:
■ A mini-storage module connector on the motherboard supports a
boot-optimized RAID controller carrier that holds up to two SATA M.2 SSDs.
■ 8GB FlexMMC utility storage for staging of firmware and other user data.
8GB FlexMMC storage is built into the motherboard on M7.
Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model) 12
BASE SERVER STANDARD CAPABILITIES and FEATURES
Capability/Feature Description
Storage controllers Internal storage controllers:
The SATA Interposer board, 24G Tri-mode RAID controller, 12G RAID controller
or 12G SAS HBA. Only one of these at a time can be used.
■ SATA Interposer board
• AHCI support up to eight SATA-only drives (slots 1-8)
■ Cisco 24G Tri-mode RAID controller
• RAID support (RAID 0, 1, 5, 6, 10, 50, 60, RAID0, and RAID00)
• Supports up to 10 internal SAS/SATA/NVMe drives
■ Cisco 12G RAID controller
• RAID support (RAID 0, 1, 5, 6, 10, 50, 60, RAID0, and RAID00)
• Supports up to 10 internal SAS/SATA drives
■ Cisco 12G SAS HBA
• No RAID support
• JBOD/Pass-through Mode support
• Supports up to 10 SAS/SATA internal drives
External storage controllers:
■ Cisco 12G 9500-8e 12G SAS HBA for external JBOD attach
Modular LAN on The dedicated mLOM/Open Compute Project (OCP) 3.0 slot on the motherboard
Motherboard (mLOM)/ can flexibly accommodate the following cards:
Open Compute Project
(OCP) 3.0 slot ■ Cisco Virtual Interface Cards
■ Open Compute Project (OCP) 3.0 network interface card
Fabric Interconnect Compatible with the Cisco UCS 6454, 64108 and 6536 fabric interconnects
UCSM1 UCS Manager (UCSM) 4.3(2) or later runs in the Fabric Interconnect and
automatically discovers and provisions some of the server components.
CIMC Cisco Integrated Management Controller 4.3(1) or later
Intersight Intersight provides server management capabilities
Firmware standards UEFI Spec 2.9
ACPI 6.5
SMBIOS Ver 3.6
13 Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER
Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model) 14
CONFIGURING the SERVER
CAUTION: This product may not be purchased outside of the approved bundles (must be
ordered under the MLB)
15 Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER
CAUTION:
■ Full-height risers cannot be mixed with half-height risers.
■ Gen4 and Gen5 risers cannot be mixed.
Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model) 16
CONFIGURING the SERVER
Approved Configurations
(1) Half-height riser 1A, 2A, and 3A only. riser 1A and 2A are controlled from CPU1 and Riser 3
is controlled from CPU2.
(2) Half-height risers 1B, 2B, and 3A only. Risers 1B and 2B are controlled from CPU1 and Riser
3A is controlled from CPU2
(3) Full-height risers 1C and 3C only. Riser 1C is controlled from CPU1 and riser 3C is controlled
from CPU2.
17 Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER
■ The 5th Gen. Intel® Xeon® Scalable Processors are paired with Intel® C741 series chipset:
— Up to 60 cores
— Cache size of up to 300 MB
— Power: Up to 300Watts
— UPI Links: Up to 3 at 20GT/s
■ The 4th Gen. Intel® Xeon® Scalable Processors are paired with Intel® C741 series chipset:
— Up to 52 cores
— Cache size of up to 105 MB
— Power: Up to 300Watts
— UPI Links: Up to 3 at 16GT/s
Select CPUs
NOTE: If you try to upgrade an existing C220M7 Server from 4th Gen CPUs to 5th Gen
CPUs, a new air duct (UCSC-AD-C220M7=) may be required. Please refer to the
installation guide for more details.
■ The available 5th Gen. Intel® Xeon® Scalable CPUs are listed in Table 5. See Table 7 on page
21 for CPU suffix notations.
■ The available 4th Gen. Intel® Xeon® Scalable CPUs are listed in Table 6. See Table 7 on page
21 for CPU suffix notations.
CAUTION: Normal operating temperature is limited to 35o C [95o F], and is lowered
to 28o C [82.4o F], with a fan fault.
Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model) 18
CONFIGURING the SERVER
19 Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER
Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model) 20
CONFIGURING the SERVER
V Cloud (SaaS) Designed for high rack density, maximize VM/core, and lower
power VM environment
M Media Transcode Designed for Media processing, AI, and HPC workloads
H DB and Analytics Designed for Data Analytics and Big Data usages
21 Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER
Y General SKU with Designator is used for general SKU stack to highlight SST-PP
SST-PP (Speed Select Technology Performance Profile) feature enabled
+ Feature Plus SKU Designed to enable 1 instance of each DSA, IAA, QAT, DLB
embedded accelerator
Supported Configurations
The selection of 1 or 2 CPUs depends on the desired server functionality. See the following
sections:
Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model) 22
CONFIGURING the SERVER
DRAM DIMM type RDIMM (Registered DDR5 DIMM with on die ECC)
Memory DIMM organization Eight memory DIMM channels per CPU; up to 2 DIMMs per channel
23 Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER
Slot 2
Slot 2
Slot 1
A1 A2 A2 A1
Chan A Chan A
B1 B2 B2 B1
Chan B
Chan B
C1 C2 C2 C1
Chan C Chan C
D1 D2 D2 D1
Chan D Chan D
CPU 1 CPU 2
E1 E2 E2 E1
Chan E Chan E
F1 F2 F2 F1
Chan F Chan F
G1 G2 G2 G1
Chan G Chan G
H1 H2 H2 H1
Chan H Chan H
Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model) 24
CONFIGURING the SERVER
Select the memory configuration and whether or not you want the memory mirroring option. The available
memory DIMMs and mirroring option are listed in Table 9.
NOTE: When memory mirroring is enabled, the memory subsystem simultaneously writes
identical data to two channels. If a memory read from one of the channels returns incorrect data
due to an uncorrectable memory error, the system automatically retrieves the data from the
other channel. A transient or soft error in one channel does not affect the mirrored data, and
operation continues unless there is a simultaneous error in exactly the same location on a DIMM
and its mirrored DIMM. Memory mirroring reduces the amount of memory available to the
operating system by 50% because only one of the two populated channels provides data.
Notes:
1. DDR5-5600 supported on Intel Xeon 5th gen. CPUs only.
2. Available post first customer ship (FCS).
3. 48Gb and 96GB memory DIMMs not supported on UCS-CPU-I3508U, UCS-CPU-I4509Y, UCS-CPU-I4510,
UCS-CPU-I4510T
4. Any empty DIMM slot must be populated with a DIMM blank to maintain proper cooling airflow.
25 Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER
2,3,4,5,7,9,10,11,12,13,14,15,
DIMM count for 1 CPU 1 8 1,6,8
16
4,6,8,10,14,18,20,22,24,26,28,
DIMM count for 2-CPU 2 16 2,12,16
30,32
NOTE(1): 12 DIMMs count for 1-CPU, 24 DIMMs count and for 2-CPU configurations are only allowed when all
DIMMs have the same density.
Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model) 26
CONFIGURING the SERVER
Table 11.0 M7 DIMM population order for 16GB, 32GB, 64GB, and128GB
DIMM Population - 16GB, 32GB, 64GB, 128GB(4th and 5th Gen. CPUs)1
#DIMMs per CPU
Slot 1 (Blue) Slot 2 (Black)
1 A1 -
2 A1, G1 -
4 A1, C1, E1, G1 -
6 A1, C1, D1, E1, F1, G1 -
8 A1, B1, C1, D1, E1, F1, G1, H1 -
122 A1, B1, C1, D1, E1, F1, G1, H1 A2, C2, E2, G2
16 A1, B1, C1, D1, E1, F1, G1, H1 A2, B2, C2, D2, E2, F2, G2, H2
Notes:
1. See DIMM Mixing Rules for allowed combinations across slots 1 and 2.
2. Only valid when DIMMs in blue and black slots are the same density.
Notes:
1. 48GB DIMMs cannot be mixed with other DIMM capacities.
2. Only 1 DPC supported by 48GB.
27 Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER
Notes:
1. 96GB DIMMs cannot be mixed with other DIMM capacities.
2. Only valid when DIMMs in blue and black slots are the same density.
■ DIMM Mixing Rules:
■ Higher rank DIMMs shall be populated on Slot 1.
■ Mixing different DIMM densities in the same slot across channels is not supported. All
populated slots of the same color must have the same DIMM density.
■ Mixing X4 and X8 DIMMs is not allowed
■ Mixing 16Gb DRAM based and 24Gb DRAM based DIMMs is not allowed. Therefore, 48GB and
96GB cannot be mixed with any other memory DIMMs
■ 48GB supports 1 DIMM Per Channel (1DPC) only
■ The DIMM mixing rules matrix is described in the Table 12 and Table 13, below
Table 12 Supported DIMM mixing and population across 2 slots in each channel - 16GB, 32GB, 64GB, and
128GB
Notes:
1. For 2,4,6, 8 DIMMs count, only populate slot 1 (Blue slot). see Table 11.0 for details
2. When mixing two different DIMM densities, all 8 channels per CPU must be populated. Use of fewer than 8
channels (16 slots per CPU) is not supported.
Table 13 Supported DIMM mixing and population across 2 slots in each channel - 48GB and 96GB DIMMs
48GB 96GB
DIMM Slot 1 (Blue)
1Rx4 2Rx4
48GB 1Rx4 No No
Notes:
1. For 6, 8 DIMMs count, only populate slot 1 (Blue slot). see Table 11.2 for details
Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model) 28
CONFIGURING the SERVER
■ Memory Limitations:
■ Memory on every CPU socket shall be configured identically.
■ Refer to Table 11.0, Table 11.1 and Table 11.2. and Table 12 and Table 13, for DIMM
population and DIMM mixing rules.
■ Cisco memory from previous generation servers (DDR3 and DDR4) is not supported with the
M7 servers.
■ For best performance, observe the following:
■ For optimum performance, populate at least one DIMM per memory channel per CPU. When
one DIMM per channel is used, it must be populated in DIMM slot 1 (blue slot farthest away
from the CPU) of a given channel.
■ The maximum 2 DPC speed is 4400 MT/s, refer to Table 14.0 and Table 14.1 for the details.
Table 14.0 DDR5-4800 DIMM 1DPC and 2DPC max speed matrix - 4th Gen. CPU
1DPC 2DPC
4th Gen. CPU Shelves
and Memory Speed
All RDIMMs All RDIMMs
Table 14.1 DDR5-5600 DIMM 1DPC and 2DPC max speed matrix - 5th Gen. CPU
1DPC 2DPC
5th Gen. CPU Shelves and Memory
Speed
All RDIMMs All RDIMMs
NOTE: For full details on supported memory configurations see the M7 Memory Guide.
29 Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER
■ Servers with SATA drives (only) are controlled by an Intel C621 PCH through the SATA
Interposer (AHCI)
■ Up to 10 SAS/SATA/NVMe drives are controlled through a Cisco 24G Tri-mode RAID controller
■ Up to 10 SAS/SATA drives are controlled through a Cisco 12G SAS RAID controller.
■ Up to 10 SAS/SATA drives are controlled through a Cisco 12G SAS pass-through HBA.
■ Use the same capacity for each drive in each RAID volume
■ For the Cisco 12G SAS RAID controller, use either all SAS HDDs, or all SAS SSDs, or all SATA SSDs in each
RAID volume
■ For the Cisco 24G Tri-mode RAID controller, use either all SAS HDDs, or all SAS SSDs, or all SATA SSDs or
NVMe SSDs in each RAID volume.
NOTE: 240 virtual drives (VDs) per controller, with up to 64 per disk group with the 12G Raid
Controller, and 16 per disk group with the 24G Tri Mode Controller.
Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model) 30
CONFIGURING the SERVER
If you do not want the default AHCI 8 SATA-only drive setup (8 internal drives in drive bays 1-8
and 2 SATA M.2 drives), select one of the following from Table 15.
NOTE:
■ If the Cisco 24G Tri-mode RAID controller, 12G SAS RAID controller or Cisco 12G SAS HBA is
selected, it is factory-installed in a dedicated slot.
■ All RAID controllers are only supported on UCSC-C220-M7S For UCSC-C220-M7N, drives are
controlled directly from the CPU.
■ The default solution is AHCI, which supports a limited number of drives, operating systems,
and virtualized environments. For a more comprehensive solution, choose a controller from
Table 15.
■ vSAN HCL listed/qualified component is UCSC-SAS-T-D
31 Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER
Notes:
1. When ordering UCSC-RAID-HP, please note that mixing SAS/SATA and NVMe drives in a single RAID volume is not
supported. Virtual drives can only be created with drives of the same type
2. U.3 NVMe drives selected with the Tri-mode RAID controller (UCSC-RAID-HP) will be set to RAID attached as the
factory default. The U.3 drives in slots 1-4 can however operate in U.2 mode, directly attached to the CPU. This
mode can be changed from the Cisco IMC if desired.
Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model) 32
CONFIGURING the SERVER
Select one of the RAID Configuration option from the following Table 16.
CAUTION: All RAID options require drives of same sector size and media type. The smallest
drive capacity will be used to calculate the RAID volume size.
Approved Configurations
33 Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER
Select Drives
■ The available NVMe SSDs drives for UCSC-C220-M7N and UCSC-C220-M7S are listed in
Table 17
■ The available SAS/SATA SSDs and HDDs drives for UCSC-C220-M7S listed Table 18
CAUTION: Cisco uses solid state drives (SSDs) from a number of vendors. All solid state
drives (SSDs) are subject to physical write limits and have varying maximum usage limitation
specifications set by the manufacturer. Cisco will not replace any solid state drives (SSDs) that
have exceeded any maximum usage specifications set by Cisco or the manufacturer, as
determined solely by Cisco.
Drive Form
Product ID (PID) PID Description Capacity
Type Factor
PCIe/NVMe SFF (2.5-inch) SFF drives
UCS-NVMEXP-I400-D 400GB 2.5in U.2 Intel P5800X Optane NVMe Extreme NVMe U.2 400 GB
Perform SSD
UCS-NVMEXP-I800-D 800GB 2.5in U.2 Intel P5800X Optane NVMe Extreme NVMe U.2 800 GB
Perform SSD
UCS-NVME4-1600-D 1.6TB 2.5in U.2 P5620 NVMe High Perf High NVMe U.2 1.6 TB
Endurance
UCS-NVME4-1920-D 1.9TB 2.5in U.2 P5520 NVMe High Perf Medium NVMe U.2 1.9 TB
Endurance
UCS-NVME4-3200-D 3.2TB 2.5in U.2 P5620 NVMe High Perf High NVMe U.2 3.2 TB
Endurance
UCS-NVME4-3840-D 3.8TB 2.5in U.2 P5520 NVMe High Perf Medium NVMe U.2 3.8 TB
Endurance
UCS-NVME4-6400-D 6.4TB 2.5in U.2 P5620 NVMe High Perf High NVMe U.2 6.4 TB
Endurance
UCS-NVME4-7680-D 7.6TB 2.5in U.2 P5520 NVMe High Perf Medium NVMe U.2 7.6 TB
Endurance
UCS-NVME4-15360-D 15.3TB 2.5in U.2 P5520 NVMe High Perf Medium NVMe U.2 15.3 TB
Endurance
UCS-NVMEQ-1536-D 15.3TB 2.5in U.2 P5316 NVMe High Perf Low NVMe U.2 15.3 TB
Endurance
UCS-NVMEG4-M960-D 1 960GB 2.5in U.3 Micron P7450 NVMe High Perf NVMe U.3 960 GB
Medium Endurance
UCS-NVMEG4-M1920D 1 1.9TB 2.5in U.3 Micron P7450 NVMe High Perf Medium NVMe U.3 1.9 TB
Endurance
Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model) 34
CONFIGURING the SERVER
Drive Form
Product ID (PID) PID Description Capacity
Type Factor
UCS-NVMEG4-M3840D1 3.8TB 2.5in U.3 Micron P7450 NVMe High Perf Medium NVMe U.3 3.8 TB
Endurance
UCS-NVMEG4-M7680D1 7.6TB 2.5in U.3 Micron P7450 NVMe High Perf Medium NVMe U.3 7.6 TB
Endurance
UCS-NVMEG4-M1536D1 15.3TB 2.5in U.3 MicronP7450 NVMe High Perf NVMe U.3 15.3 TB
Medium Endurance
UCS-NVMEG4-M1600D1 1.6TB 2.5in U.3 Micron P7450 NVMe High Perf High NVMe U.3 1.6 TB
Endurance
UCS-NVMEG4-M3200D1 3.2TB 2.5in U.3 Micron P7450 NVMe High Perf High NVMe U.3 3.2 TB
Endurance
UCS-NVMEG4-M6400D1 6.4TB 2.5in U.3 Micron P7450 NVMe High Perf High NVMe U.3 6.4 TB
Endurance
■ CBL-FNVME-C220M7 is auto included with selection of U.3 NVMe drives and Raid controller
UCSC-RAID-HP.
Notes:
1. Only U.3 drives are allowed with RAID 24G Tri-mode RAID Controller and NVMe Hardware RAID.
Drive
Product ID (PID) PID Description Capacity
Type
HDDs
HDDs (10K RPM)
UCS-HD600G10KJ4-D 600 GB 12G SAS 10K RPM SFF HDD SAS 600 GB
UCS-HD12TB10KJ4-D 1.2 TB 12G SAS 10K RPM SFF HDD SAS 1.2 TB
UCS-HD18TB10KJ4-D 1.8 TB 12G SAS 10K RPM SFF HDD (4K) SAS 1.8 TB
UCS-HD24TB10KJ4-D 2.4 TB 12G SAS 10K RPM SFF HDD (4K) SAS 2.4 TB
Enterprise Performance SAS/SATA SSDs (High endurance, supports up to 10X or 3X DWPD (drive writes
per day))
SATA
UCS-SD480G63XEP-D 480 GB 2.5in Enterprise Performance 6G SATA SSD(3X endurance) SATA 480 GB
UCS-SD960G63XEP-D 960 GB 2.5in Enterprise performance 6G SATA SSD(3X endurance) SATA 960 GB
UCS-SD19T63X-EP-D 1.9 TB 2.5in Enterprise performance 6G SATA SSD(3X endurance) SATA 1.9 TB
UCS-SD38T63X-EP-D 3.8 TB 2.5in Enterprise performance 6G SATA SSD(3X endurance) SATA 3.8 TB
UCS-SD480GBM3XEPD 480GB SATA SSD 3DWPD SATA 480 GB
UCS-SD960GBM3XEPD 960GB SATA SSD 3DWPD SATA 960 GB
UCS-SD19TBM3XEP-D 1.9TB SATA SSD 3DWPD SATA 1.9 TB
SAS
UCS-SD800GK3XEP-D 800 GB 2.5in Enterprise Performance 12G SAS SSD(3X endurance) SAS 800 GB
UCS-SD16TK3X-EP-D 1.6 TB 2.5in Enterprise Performance 12G SAS SSD(3X endurance) SAS 1.6 TB
UCS-SD32TK3X-EP-D 3.2 TB 2.5in Enterprise Performance 12G SAS SSD(3X endurance) SAS 3.2 TB
UCS-SD16TKA3XEP-D 1.6TB 2.5in Enterprise Performance 12G SAS SSD(3X endurance) SAS 1.6 TB
UCS-SD32TKA3XEP-D 3.2TB 2.5in Enterprise Performance 12G SAS SSD(3X endurance) SAS 3.2 TB
35 Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER
Drive
Product ID (PID) PID Description Capacity
Type
UCS-SD64TS3XEP-D 6.4TB 2.5in Enterprise Performance 12G SAS SSD(3X endurance) SAS 6.4 TB
Enterprise Value SAS/SATA SSDs (Low endurance, supports up to 1X DWPD (drive writes per day))
SATA
UCSSD480G6I1XEV-D 480GB 2.5 inch Enterprise Value 6G SATA SSD SATA 480 GB
UCSSD960G6S1XEV-D 960GB 2.5 inch Enterprise Value 6G SATA SSD SATA 960 GB
UCSSD960G6I1XEV-D 960GB 2.5 inch Enterprise Value 6G SATA SSD SATA 960 GB
UCS-SD19T6S1XEV-D 1.9TB 2.5 inch Enterprise Value 6G SATA SSD SATA 1.9 TB
UCS-SD38T6S1XEV-D 3.8 TB 2.5 inch Enterprise Value 6G SATA SSD SATA 3.8 TB
UCS-SD38T6I1XEV-D 3.8TB 2.5 inch Enterprise Value 6G SATA SSD SATA 3.8 TB
UCS-SD76T6S1XEV-D 7.6TB 2.5 inch Enterprise Value 6G SATA SSD SATA 7.6 TB
UCS-SD76TM1X-EV-D 7.6TB 2.5 inch Enterprise Value 6G SATA SSD SATA 7.6 TB
UCS-SD240GBM1XEVD 240GB SATA SSD 1DWPD SATA 240 GB
UCS-SD480GBM1XEVD 480GB SATA SSD 1DWPD SATA 480 GB
UCS-SD960GBM1XEVD 960GB SATA SSD 1DWPD SATA 960 GB
UCS-SD16TBM1XEV-D 1.6GB SATA SSD 1DWPD SATA 1.6 TB
UCS-SD19TBM1XEV-D 1.9TB SATA SSD 1DWPD SATA 1.9 TB
UCS-SD38TBM1XEV-D 3.8TB SATA SSD 1DWPD SATA 3.8 TB
UCS-SD76TBM1XEV-D 7.6TB SATA SSD 1DWPD SATA 7.6 TB
UCS-SDB960SA1VD 960GB 2.5in 6G SATA Enter Value 1X Samsung G1PM893A SSD SATA 960 GB
UCS-SDB1T9SA1VD 1.9TB 2.5in 6G SATA Enter Value 1X Samsung G1PM893A SSD SATA 1.9 TB
UCS-SDB3T8SA1VD 3.8TB 2.5in 6G SATA Enter Value 1X Samsung G1PM893A SSD SATA 3.8 TB
UCS-SDB7T6SA1VD 7.6TB 2.5in 6G SATA Enter Value 1X Samsung G1PM893A SSD SATA 7.6 TB
SAS
UCS-SD960GK1XEV-D 960GB 2.5 inch Enterprise Value 12G SAS SSD SAS 960 GB
UCS-SD19TK1X-EV-D 1.9TB 2.5 inch Enterprise Value 12G SAS SSD SAS 1.9 TB
UCS-SD38TK1X-EV-D 3.8TB 2.5 inch Enterprise Value 12G SAS SSD SAS 3.8 TB
UCS-SD76TK1X-EV-D 7.6TB 2.5 inch Enterprise Value 12G SAS SSD SAS 7.6 TB
UCS-SD15TK1X-EV-D 15.3TB 2.5 inch Enterprise Value 12G SAS SSD SAS 15.3 TB
UCS-SD19TKA1XEV-D 1.9TB 2.5 inch Enterprise Value 12G SAS SSD SAS 1.9 TB
UCS-SD38TKA1XEV-D 3.8TB 2.5 inch Enterprise Value 12G SAS SSD SAS 3.8 TB
UCS-SD76TKA1XEV-D 7.6TB 2.5 inch Enterprise Value 12G SAS SSD SAS 7.6 TB
UCS-SD76TS1X-EV-D 7.6TB 2.5 inch Enterprise Value 12G SAS SSD SAS 7.6 TB
UCS-SD15TKA1XEV-D 15.3TB 2.5 inch Enterprise Value 12G SAS SSD SAS 15.3 TB
Self-Encrypted Drives (SED) (1X or 3X)
SATA
UCSSD38TBEM2NK9-D 3.8TB Enterprise value SATA SSD (1X, SED) Non FIPS SATA 3.8 TB
SAS
UCS-SD800GBKNK9-D 800GB Enterprise Performance SAS SSD (3X DWPD, SED) FIPS140-2 SAS 800 GB
Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model) 36
CONFIGURING the SERVER
Drive
Product ID (PID) PID Description Capacity
Type
UCS-SD960GBKNK9-D 960GB Enterprise Value SAS SSD (1X DWPD, SED) FIPS140-2 SAS 960 GB
UCS-SD16TBKNK9-D 1.6TB Enterprise performance SAS SSD (3X DWPD, SED) FIPS140-2 SAS 1.6 TB
UCS-SD38TBKNK9-D 3.8TB Enterprise Value SAS SSD (1X DWPD, SED) FIPS140-2 SAS 3.8 TB
UCS-SD76TBKNK9-D 7.6TB Enterprise value SAS SSD (1X DWPD, SED-FIPS) FIPS140-2 SAS 7.6 TB
UCS-SD16TBKANK9-D 1.6TB 2.5" Enterprise performance 12GSAS SSD(3DWPD,SED-FIPS) SAS 1.6 TB
FIPS140-2
UCS-SD38TBKANK9-D 3.8TB 2.5" Enterprise value 12G SAS SSD (1DWPD, SED-FIPS) SAS 3.8 TB
FIPS140-2
UCS-SD76TBKANK9-D 7.6TB Enterprise value SAS SSD (1DWPD, SED-FIPS) SAS 7.6 TB
FIPS140-2
UCS-SD960GM2NK9-D 960GB SED SSD 1DWPD SAS 960 GB
UCS-SD19TEM2NK9-D 1.9TB SED SSD 1DWPD SAS 1.9 TB
UCS-SD38TEM2NK9-D 3.8TB SED SSD 1DWPD SAS 3.8 TB
UCS-SD76TEM2NK9-D 7.6TB SED SSD 1DWPD SAS 7.6 TB
Accessories/spare included with drives (For UCSC-C220-M7S):
■ CBL-FNVME-C220M7 is auto included with selection of U.3 NVMe drives and Raid controller UCSC-RAID-HP
■ CBL-SATA-C220-D is included with the selection of the SATA drives.
■ UCSC-BBLKD-M7 is included for the not selected front storage device.
NOTE: If you are adding drive later as spare, you may need to order cables with it.
Caveats
37 Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER
Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model) 38
CONFIGURING the SERVER
Notes:
1. HHHL = half-height, half-length; FHHL = full-height, half-length; SS = single-slot; DS = double-slot. SFF
= small form factor.
2. For installation in the mLOM slot, you can order either an mLOM VIC, or the OCP NIC - but not both. If
ordering the OCP NIC, the OCP Mechanical Kit (UCSC-OCP3-KIT) must also be installed in order to
mount OCP NIC in the mLOM slot.
3. When present, the recommended Fan Speed Control policy setting is balanced.
4. NICs with 16 active electrical lanes, such as the 100G NICs, can be inserted in slots with 8 active
electrical lanes.The NIC will function but may exhibit degraded performance.
5. This Virtual Interface Cards incorporate VIC Secure Boot technology
Approved Configurations
■ You can select up to two of the PCIe option cards listed in Table 19 to be installed in Riser 1
and Riser 2. Riser 1 and Riser 2 is controlled by CPU 1. Risers 3 cannot installed in a 1-CPU
system.
39 Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER
■ You can select up to two of the PCIe option cards listed in Table 19 for a two-riser system
and up to three of the PCIe option cards for a three-riser system. Risers 1 and 2 are
controlled by CPU and riser 3 is controlled by CPU 2.
Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model) 40
CONFIGURING the SERVER
Caveats
■ For installation in the mLOM slot, you can order either an mLOM VIC, or the OCP NIC - but
not both. If ordering the OCP NIC, the OCP Mechanical Kit (UCSC-OCP3-KIT) must also be
installed in order to mount OCP NIC in the mLOM slot.
Intel:
Product Guide
Speed White Paper
41 Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER
CAUTION:
■ Gen4 and Gen5 risers cannot be mixed, for example: If UCSC-RIS2A-C22XM7
(GEN4) is selected, cannot select UCSC-RIS2B-C22XM7 (GEN5)
Maximum
Product ID (PID) PID Description Card Size cards Per Riser Compatibility
node
NVIDIA L4:70W,
HHHL, Gen 4 & Gen 5 Half Height and
UCSC-GPU-L4 24GB, 1-slot 3 Full Hight Riser
single-wide
HHHL GPU
Notes:
1. Refer to installation guide for the more details.
NOTE:
■ All GPU cards must be procured from Cisco as there is a unique SBIOS ID
required by CIMC and UCSM
■ GPUs cannot be mixed.
Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model) 42
CONFIGURING the SERVER
Use the power calculator at the following link to determine the needed power based on the options chosen
(CPUs, drives, memory, and so on):
http://ucspowercalc.cisco.com
WARNING:
■ Starting 1st January 2024, only Titanium rated PSUs are allowed to be shipped to
European Union (EU), European Economic Area (EEA), United Kingdom (UK),
Switzerland and other countries that adopted Lot 9 Regulation.
■ DC PSUs are not impacted by Lot 9 Regulation and are EU/UK Lot 9 compliant
NOTE:
■ In a server with two power supplies, both power supplies must be identical.
■ Refer to Power Specifications, page 81 section for the full details on the each power
supply.
43 Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER
NOTE: Table 22 lists the power cords for servers that use power supplies less than 2300 W.
Table 23 lists the power cords for servers that use 2300 W power supplies. Note that the power
cords for 2300 W power supplies use a C19 connector so they only fit the 2300 W power supply
connector.
Table 22 Available Power Cords (for server PSUs less than 2300 W)
Connector:
IEC60320/C13
186570
CAB-AC-L620-C13-D AC Power Cord, NEMA L6-20 - C13,
2M/6.5ft
Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model) 44
CONFIGURING the SERVER
Table 22 Available Power Cords (for server PSUs less than 2300 W)
186571
CAB-9K10A-AU Power Cord, 250VAC 10A 3112 Plug,
Australia
Cordset rating: 10 A, 250 V/500 V MAX
Length: 2500mm
Connector:
Plug: EL 701C
EL 210 (EN 60320/C15)
186580
(BS 1363A) 13 AMP fuse
186576
CAB-250V-10A-ID Power Cord, 250V, 10A, India
OVE
Connector:
EL 701
187490
Connector:
Plug: EL 701B
EL 212 (IEC60320/C13)
186574
(SI-32)
45 Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER
Table 22 Available Power Cords (for server PSUs less than 2300 W)
186575
CAB-9K10A-SW Power Cord, 250VAC 10A MP232
Plug, Switzerland
Cordset rating: 10 A, 250 V
Plug: Length: 8 ft. 2 in (2.5 m)
MP232-R
Connector:
IEC 60320 C15
186578
CAB-9K10A-UK Power Cord, 250VAC 10A BS1363
Plug (13 A fuse), UK
Cordset rating: 10 A, 250 V/500 V MAX
Length: 2500mm
Connector:
Plug: EL 701C
EL 210 (EN 60320/C15)
186580
(BS 1363A) 13 AMP fuse
2,133.6 ± 25
Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model) 46
CONFIGURING the SERVER
CAB-C19-CBN Cabinet Jumper Power Cord, 250 VAC 16A, Not applicable
C20-C19 Connectors
CAB-9K16A-BRZ Power Cord 250VAC 16A, Brazil, Src Plug Image not available
EL224-C19
CAB-9K16A-KOR Power Cord 250VAC 16A, Korea, Src Plug Image not available
CAB-AC-16A-AUS Power Cord, 250VAC, 16A, Australia C19 Image not available
CAB-AC-C19-TW Power Cord, 250 V, 16A, C19, Taiwan Image not available
CAB-AC-C6K-TWLK Power Cord, 250Vac 16A, twist lock NEMA Image not available
L6-20 plug, US
CAB-C19-C20-3M-JP Power Cord C19-C20, 3M/10ft Japan PSE mark Image not available
UCSB-CABL-C19-BRZ NBR 14136 to C19 AC 14FT POWER CORD, Image not available
BRAZIL
NO-POWER-CORD ECO friendly green option, no power cable Image not available
will be shipped
47 Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER
Select a tool-less rail kit (or no rail kit) from Table 24.
NOTE:
■ Cisco recommends a minimum quantity of 1 Rail Kit
■ If you plan to rackmount your UCS C220 M7 server, you must order a tool-less rail kit.
UCSC-RAIL-D Ball Bearing Rail Kit for C220 & C240 M6/M7 rack servers
The reversible cable management arm mounts on either the right or left slide rails at the rear of the server
and is used for cable management. Select an Optional Reversible Cable Management Arm from Table 25.
NOTE: If you plan to rackmount your UCS C220 M7 server, you must order a tool-less rail kit. The
same rail kits and CMAs are used for M6 and M7 servers.
UCSC-CMA-C220-D Reversible CMA for C220 M6/M7 ball bearing rail kit
For more information about the tool-less rail kit and cable management arm, check the Cisco
UCS C220 M7 Installation Guide.
Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model) 48
CONFIGURING the SERVER
NOTE:
■ There are no LOM ports on the C220 and C240 M7 servers. Servers ordered
without a VIC or OCP card will ship in Dedicated network mode, unless otherwise
specified by a configurable SW PID (UCSC-CCARD-01)
■ For full details on all the NIC mode settings, see
https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/c/hw/C220M7/in
stall/b-c220-m7-installation-guide.html
In addition, the optional software PIDs listed in Table 34 on page 53 can be ordered for setting
the server to operate in various modes.
49 Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER
A chassis intrusion switch gives a notification of any unauthorized mechanical access into the
server.
NOTE:
■ The TPM module used in this system conforms to TPM v1.2 and 2.0, as defined
by the Trusted Computing Group (TCG). It is also SPI-based.
■ TPM installation is supported after-factory. However, a TPM installs with a
one-way screw and cannot be replaced, upgraded, or moved to another server. If
a server with a TPM is returned, the replacement server must be ordered with a
new TPM.
Notes:
1. Please note that Microsoft certification requires a TPM 2.0 for bare-metal or guest VM deployments. Opt-out
of the TPM 2.0 voids the Microsoft certification
Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model) 50
CONFIGURING the SERVER
51 Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER
NOTE:
■ It is recommended that M.2 SATA SSDs be used as boot-only devices.
■ Order one or two identical M.2 SATA SSDs for the boot optimized RAID controller
■ You cannot mix M.2 SATA SSD capacities.
■ Order Cisco boot optimized M.2 RAID controller from Table 30. The boot optimized RAID controller
plugs into a connector on the motherboard and holds up to two M.2 SATA drives.
NOTE:
■ The Cisco boot optimized M.2 RAID controller supports VMWare, Windows and Linux
Operating Systems
■ The Cisco boot optimized M.2 RAID controller supports RAID 1 and JBOD mode
■ The Cisco boot optimized M.2 RAID controller is available only with 240GB, 480GB, and
960GB M.2 SSDs.
■ CIMC is supported for configuring of volumes and monitoring of the controller and installed
SATA M.2 drives
■ The SATA M.2 drives can boot in UEFI mode only. Legacy boot mode is not supported
■ Hot-plug replacement is not supported. The server must be powered off.
UCS-M2-HWRAID-D Cisco Boot optimized M.2 RAID controller (holds up to two M.2 SATA SSDs)
Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model) 52
CONFIGURING the SERVER
NOTE:
■ It is recommended that M.2 NVMe be used as boot-only devices.
■ Order one or two identical M.2 NVMe for the boot optimized RAID controller
■ You cannot mix M.2 NVMe capacities.
■ Order Cisco boot optimized M.2 NVMe RAID controller from Table 32. The boot optimized RAID
controller plugs into a connector on the motherboard and holds up to two M.2 NVMe drives.
Table 33 Riser supported Matrix for M.2 NVMe Boot Raid Controller
53 Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER
NOTE:
■ See this link for operating system guidance:
https://ucshcltool.cloudapps.cisco.com/public/
■ VMware is on Compliance Hold. Contact the
[email protected] mailer to see if you are allowed to receive
VMware Licenses
VMware vCenter
MSWS-22-ST16CD-NS Windows Server 2022 Standard (16 Cores/2 VMs) - No Cisco SVC
MSWS-19-ST16CD-NS Windows Server 2019 Standard (16 Cores/2 VMs) - No Cisco SVC
Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model) 54
CONFIGURING the SERVER
Red Hat
RHEL-2S2V-D1A Red Hat Enterprise Linux (1-2 CPU,1-2 VN); 1-Yr Support Req
RHEL-2S2V-D3A Red Hat Enterprise Linux (1-2 CPU,1-2 VN); 3-Yr Support Req
RHEL-2S2V-D5A Red Hat Enterprise Linux (1-2 CPU,1-2 VN); 5-Yr Support Req
RHEL-VDC-2SUV-D1A RHEL for Virt Datacenters (1-2 CPU, Unlim VN) 1 Yr Supp Req
RHEL-VDC-2SUV-D3A RHEL for Virt Datacenters (1-2 CPU, Unlim VN) 3 Yr Supp Req
RHEL-VDC-2SUV-D5A RHEL for Virt Datacenters (1-2 CPU, Unlim VN) 5 Yr Supp Req
RHEL-2S2V-D1S Red Hat Enterprise Linux (1-2 CPU,1-2 VN); Prem 1Yr SnS Reqd
RHEL-2S2V-D3S Red Hat Enterprise Linux (1-2 CPU,1-2 VN); Prem 3Yr SnS Reqd
RHEL-2S-HA-D1S RHEL High Availability (1-2 CPU); Premium 1-yr SnS Reqd
RHEL-2S-HA-D3S RHEL High Availability (1-2 CPU); Premium 3-yr SnS Reqd
RHEL-2S-RS-D1S RHEL Resilent Storage (1-2 CPU); Premium 1-yr SnS Reqd
RHEL-2S-RS-D3S RHEL Resilent Storage (1-2 CPU); Premium 3-yr SnS Reqd
RHEL-VDC-2SUV-D1S RHEL for Virt Datacenters (1-2 CPU, Unlim VN) 1 Yr SnS Reqd
RHEL-VDC-2SUV-D3S RHEL for Virt Datacenters (1-2 CPU, Unlim VN) 3 Yr SnS Reqd
RHEL-SAP-2S2V-D1S RHEL for SAP Apps (1-2 CPU, 1-2 VN); Prem 1-Yr SnS Reqd
RHEL-SAP-2S2V-D3S RHEL for SAP Apps (1-2 CPU, 1-2 VN); Prem 3-Yr SnS Reqd
VMware
VMW-VSP-EPL-D1A VMware vSphere 7 Ent Plus (1 CPU, 32 Core) 1Yr, Support Reqd
VMW-VSP-EPL-D3A VMware vSphere 7 Ent Plus (1 CPU, 32 Core) 3Yr, Support Reqd
VMW-VSP-EPL-D5A VMware vSphere 7 Ent Plus (1 CPU, 32 Core) 5Yr, Support Reqd
55 Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER
SUSE
SLES-2S2V-D1A SUSE Linux Enterprise Svr (1-2 CPU,1-2 VM); 1-Yr Support Req
SLES-2S2V-D3A SUSE Linux Enterprise Svr (1-2 CPU,1-2 VM); 3-Yr Support Req
SLES-2S2V-D5A SUSE Linux Enterprise Svr (1-2 CPU,1-2 VM); 5-Yr Support Req
SLES-2SUVM-D1A SUSE Linux Enterprise Svr (1-2 CPU,Unl VM) LP; 1Y Supp Req
SLES-2SUVM-D3A SUSE Linux Enterprise Svr (1-2 CPU,Unl VM) LP; 3Y Supp Req
SLES-2SUVM-D5A SUSE Linux Enterprise Svr (1-2 CPU,Unl VM) LP; 5Y Supp Req
SLES-2S-LP-D1A SUSE Linux Live Patching Add-on (1-2 CPU); 1yr Support Req
SLES-2S-LP-D3A SUSE Linux Live Patching Add-on (1-2 CPU); 3yr Support Req
SLES-2S2V-D1S SUSE Linux Enterprise Svr (1-2 CPU,1-2 VM); Prio 1-Yr SnS
SLES-2S2V-D3S SUSE Linux Enterprise Svr (1-2 CPU,1-2 VM); Prio 3-Yr SnS
SLES-2S2V-D5S SUSE Linux Enterprise Svr (1-2 CPU,1-2 VM); Prio 5-Yr SnS
SLES-2SUVM-D1S SUSE Linux Enterprise Svr (1-2 CPU,Unl VM) LP; Prio 1Y SnS
SLES-2SUVM-D3S SUSE Linux Enterprise Svr (1-2 CPU,Unl VM) LP; Prio 3Y SnS
SLES-2SUVM-D5S SUSE Linux Enterprise Svr (1-2 CPU,Unl VM) LP; Prio 5Y SnS
SLES-2S-HA-D1S SUSE Linux High Availability Ext (1-2 CPU); 1yr SnS
SLES-2S-HA-D3S SUSE Linux High Availability Ext (1-2 CPU); 3yr SnS
SLES-2S-HA-D5S SUSE Linux High Availability Ext (1-2 CPU); 5yr SnS
SLES-2S-GC-D1S SUSE Linux GEO Clustering for HA (1-2 CPU); 1yr Sns
SLES-2S-GC-D3S SUSE Linux GEO Clustering for HA (1-2 CPU); 3yr SnS
SLES-2S-GC-D5S SUSE Linux GEO Clustering for HA (1-2 CPU); 5yr SnS
SLES-2S-LP-D1S SUSE Linux Live Patching Add-on (1-2 CPU); 1yr SnS Required
SLES-2S-LP-D3S SUSE Linux Live Patching Add-on (1-2 CPU); 3yr SnS Required
SLES-SAP-2S2V-D1S SLES for SAP Apps (1-2 CPU, 1-2 VM); Priority 1-Yr SnS
SLES-SAP-2S2V-D3S SLES for SAP Apps (1-2 CPU, 1-2 VM); Priority 3-Yr SnS
SLES-SAP-2S2V-D5S SLES for SAP Apps (1-2 CPU, 1-2 VM); Priority 5-Yr SnS
SLES-SAP-2S2V-D1A SLES for SAP Apps w/ HA (1-2 CPU, 1-2 VM); 1-Yr Support Reqd
SLES-SAP-2S2V-D3A SLES for SAP Apps w/ HA (1-2 CPU, 1-2 VM); 3-Yr Support Reqd
Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model) 56
CONFIGURING the SERVER
SLES-SAP-2S2V-D5A SLES for SAP Apps w/ HA (1-2 CPU, 1-2 VM); 5-Yr Support Reqd
57 Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER
Table 36 OS Media
MSWS-19-ST16CD-RM Windows Server 2019 Stan (16 Cores/2 VMs) Rec Media DVD Only
MSWS-19-DC16CD-RM Windows Server 2019 DC (16Cores/Unlim VM) Rec Media DVD Only
MSWS-22-ST16CD-RM Windows Server 2022 Stan (16 Cores/2 VMs) Rec Media DVD Only
MSWS-22-DC16CD-RM Windows Server 2022 DC (16Cores/Unlim VM) Rec Media DVD Only
Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model) 58
SUPPLEMENTAL MATERIAL
SUPPLEMENTAL MATERIAL
Block Diagrams
NOTE: Only one drive configuration option is possible at a time UCSC-C220-M7S SFF Block Diagram Rear Panel
UCSC-C220-M7S USB 3.0 x 1 USB 3.0/2.0
OPTION 1 USB 3.0 x 1
USB 3.0/2.0
Front drives 1-4 & 6-9
all SATA RGB VGA
1 COM
SATA Serial
2 Interposer
3 Drive
Intel
4
Backplane X8 MiniSAS X8 Slimline SATA 3.0 x8 EMMITSBURG USB 2.0 x1
6 Connector connector PCH
7 PCIe 2.0 x 1
8 eSPI RGMII 1 GB-T
9 DMI3 RGMII/MDI (Mgmt)
BMC
PCIe 3.0 x4 SATA 3.0 x4
Mini Storage
. . . . . . . . . . . .
OPTION 2 DDR5 DIMMs
Network connectors
A1 A2
Front drives 1-10
SAS/SATA only Chan A
DMI3
1
2 B1 B2 mLOM/OCP
3 12G RAID
4 Drive Controller CPU1
Chan B Module
SAS/SATA PCIe 4.0 x 16
5 Backplane or 12G SAS PCIe 4.0 x 8 C1 C2
6 HBA Chan C PCIe 4.0 x 16
7
8 CPU1
D1 D2 PCIe 5.0 x 16
9
Chan D
10
4th Gen Intel® Xeon®
E1 E2 Scalable Processor
Chan E (Sapphire Rapids) Front Panel
KVM
Connector
F1 F2
OPTION 3
Front drives CPU2 PCIe 4.0 x 16 (for 4 NVMe drives) Chan F
1-4 SAS/SATA or NVMe
5-10 SAS/SATA only USB 2.0 x 2
G1 G2
1 VGA
1 NVMe Chan G
. 1 Serial COM
2 .
3 . H1 H2
NVMe 12G RAID CPU1
4 PCIe 4.0 x 8 Chan H
SAS/SATA
Drive Controller or (for SAS/SATA drives)
5 Backplane 12G SAS
6 .
.
HBA
7 UPI (3x 16 GT/s)
. DDR5 DIMMs PCIe Riser 1A (1 HH slot)
8
A1 A2
9 SAS/SATA Slot 1
PCIe 4.0 x 16
10 Chan A
B1 B2
PCIe Riser 2A (1 HH slot)
Chan D
4th Gen Intel® Xeon® PCIe 5.0 x 16
1 SAS/ PCIe Riser 1B (1 HH slot)
SATA/ E1 E2 Scalable Processor
2
NVMe Chan E (Sapphire Rapids) PCIe 5.0 x 16 Slot 1
3
4 CPU1
PCIe 4.0 x 16 F1 F2 2 HH Gen 5 Riser Configuration
Drive 24G RAID PCIe Riser 2B (1 HH slot)
(for SAS/SATA/NVMe drives) Chan F
5 Backplane Controller Slot 1
SAS/ PCIe 5.0 x 16
6 SATA/ G1 G2
7 NVMe
8 Chan G
9
H1 H2
10
Chan H PCIe 5.0 x 16 PCIe Riser 1C (1 FH slot)
Slot 1
59 Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model)
SUPPLEMENTAL MATERIAL
NOTE: Only one drive configuration option is possible at a time UCSC-C220-M7N SFF Block Diagram Rear Panel
USB 3.0 x 1 USB 3.0/2.0
USB 3.0 x 1
USB 3.0/2.0
RGB VGA
UCSC-C220-M7N
COM
Serial
Intel
EMMITSBURG USB 2.0 x1
PCH
PCIe 2.0 x 1
eSPI RGMII 1 GB-T
DMI3 RGMII/MDI (Mgmt)
BMC
PCIe 3.0 x4 SATA 3.0 x4
Mini Storage
. . . . . . . . . . . .
DDR5 DIMMs
Network connectors
A1 A2
Chan A
DMI3
B1 B2 mLOM/OCP
Chan B Module
PCIe 4.0 x 16
C1 C2
Chan C PCIe 4.0 x 16
CPU1
D1 D2 PCIe 5.0 x 16
Chan D
4th Gen Intel® Xeon®
E1 E2 Scalable Processor
Chan E (Sapphire Rapids) Front Panel
KVM
Connector
F1 F2
Chan F
USB 2.0 x 2
G1 G2
1 VGA
UCSC-C220-M7N Front drives Chan G
1 Serial COM
1-10
all NVMe H1 H2
CPU2 Chan H
NVMe PCIe 4.0 x 16
1
2 .
3 . UPI (3x 16 GT/s)
DDR5 DIMMs PCIe Riser 1A (1 HH slot)
4 .
.
Drive CPU2 A1 A2
Slot 1
PCIe 4.0 x 8 PCIe 4.0 x 16
5 . Backplane Chan A
6 .
. B1 B2
PCIe Riser 2A (1 HH slot)
7 . Slot 1
Chan B PCIe 4.0 x 16 3 HH Gen 4 Riser Configuration
8
9 CPU1 C1 C2
NVMe PCIe Riser 3A (1 HH slot)
PCIe 4.0 x 16 Chan C
10
CPU2 PCIe 4.0 x 16 Slot 1
D1 D2
Chan D
4th Gen Intel® Xeon® PCIe 5.0 x 16
F1 F2
PCIe Riser 2B (1 HH slot) 2 HH Gen 5 Riser Configuration
Chan F
PCIe 5.0 x 16 Slot 1
G1 G2
Chan G
H1 H2
Slot 1
Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model) 60
SUPPLEMENTAL MATERIAL
Chassis
Figure 7 and Figure 8 shows the Internal views of the C220 M7 chassis with the top cover removed.
Figure 7 C220 M7 SFF With Top Cover Off (full-height, full-width PCIe cards)
1 2 3 4 5 6 7 8
10
11
309137
13 3 12
61 Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model)
SUPPLEMENTAL MATERIAL
Figure 8 C220 M7 SFF With Top Cover Off (full-height, half-width PCIe cards)
1 2 3 4 5 6 7 8
10
11
12
309138
14 3 13
Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model) 62
SUPPLEMENTAL MATERIAL
Risers
Figure 9 shows the locations of the PCIe riser connectors on the C220 M7 SFF motherboard. The allowed
configurations are:
Riser 3 Connector
Riser 2 Connector
Riser 1 Connector
63 Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model)
SUPPLEMENTAL MATERIAL
Figure 10 shows three half-height risers plugged into their respective connectors.
Riser 3 Connector
Half-Height Riser 3
Half-Height Riser 2
Half-Height Riser 1
Riser 1 Connector
Riser 2 Connector
Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model) 64
SUPPLEMENTAL MATERIAL
Figure 11 shows two full-height risers plugged in. Note that riser 1 is plugged into the riser 1 connector and
riser 2 is plugged into the riser 3 connector. Riser 2 connector is not used.
Riser 3 Connector
Full-Height Riser 2
FullHeight Riser 1
Riser 1 Connector
65 Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model)
SUPPLEMENTAL MATERIAL
Pin Signal
1 RTS (Request to Send)
2 DTR (Data Terminal Ready)
3 TxD (Transmit Data)
4 GND (Signal Ground)
5 GND (Signal Ground)
6 RxD (Receive Data)
7 DSR (Data Set Ready)
8 CTS (Clear to Send)
KVM Cable
The KVM cable provides a connection into the server, providing a DB9 serial connector, a VGA connector for
a monitor, and dual USB ports for a keyboard and mouse. With this cable, you can create a direct
connection to the operating system and the BIOS running on the server.
The KVM cable ordering information is listed in Table 37.
2 DB-9 serial connector 4 Two-port USB connector (for a mouse and keyboard)
Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model) 66
UPGRADING or REPLACING CPUs and Memory
67 Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model)
SPARE PARTS
SPARE PARTS
This section lists the upgrade and service-related parts for the UCS C220 M7 server. Some of these parts are
configured with every server.
NOTE: Some spare parts you order may also require accessories for full
functionality. For example, drives or RAID controllers may need accompanying
cables. CPUs may need heatsinks, thermal paste, and installation tools. The spares
and their accessory parts are listed in Table 38.
Note: If you are ordering a second CPU, see the CPU Accessories section in this table for additional parts
you may need to order for the second CPU.
5th Gen. CPUs
8000 Series Processors
UCS-CPU-I8581V=
UCS-CPU-I8571N=
UCS-CPU-I8562Y+=
UCS-CPU-I8558U=
6000 Series Processors
UCS-CPU-I6554S=
UCS-CPU-I6548Y+=
UCS-CPU-I6548N=
UCS-CPU-I6544Y=
UCS-CPU-I6542Y=
Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model) 68
SPARE PARTS
69 Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model)
SPARE PARTS
Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model) 70
SPARE PARTS
71 Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model)
SPARE PARTS
Note: When ordering additional RAID controllers, you may need to order a cable/supercap to connect
from the RAID controller to the motherboard. See the RAID Controller Accessories section in this table.
UCSC-RAID-HP= Cisco Tri-Mode 24G SAS RAID Controller w/4GB Cache
UCSC-RAID-HP= accessories (note: the below accessories only required if it is not in the system
configuration. Must select all option within a single accessory or OPTOUT PID.
UCS-SCAP-D= M6 SuperCap
CBL-SCAP-C220-D= C220/C240M6 1U/2U Super Cap cable
CBL-SAS-Y-C220M7= C220M7 SAS CABLE; MB CPU1 P-1 to HP RAID Controller
UCSC-HPBKT-22XM7= UCS C-Series M7 1U HP RAID Controller Bracket
UCSC-OPTOUT= Opt out from Ordering Accessories
UCSC-RAID-T-D= Cisco M6 12G SAS RAID Controller with 4GB FBWC (16 Drives)
UCSC-RAID-T-D= accessories (note: the below accessories only required if it is not in the system
configuration. Must select all option within a single accessory or OPTOUT PID.
UCS-SCAP-D= M6 SuperCap
CBL-SCAP-C220-D= C220/C240M6 1U/2U Super Cap cable
CBL-SAS-C220M7= C220M7 SAS CABLE; MB CPU1 P-1 to SAS RAID Controller
UCSC-RDBKT-22XM7= UCS C-Series M7 1U RAID/HBA Controller Bracket
UCSC-OPTOUT= Opt out from Ordering Accessories
UCSC-SAS-T-D= Cisco M6 12G SAS HBA for (16 Drives)
UCSC-SAS-T-D= accessories (note: the below accessories only required if it is not in the system
configuration. Must select all option within a single accessory or OPTOUT PID.
UCSC-RDBKT-22XM7= UCS C-Series M7 1U RAID/HBA Controller Bracket
CBL-SAS-C220M7= C220M7 SAS CABLE; MB CPU1 P-1 to SAS RAID Controller
Controller for External Drives
UCSC-9500-8E-D= Cisco 12G 9500-8e 12G SAS HBA for external JBOD attach
SATA Interposer
UCSC-SATAIN-220M7= UCS C220 M7 SATA Interposer Board (for control of up to 8 SATA-only drives
using AHCI)
Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model) 72
SPARE PARTS
Note: When ordering additional SAS/SATA or NVMe front or rear drives, you may need to order a cable to
connect from the drive to the motherboard. See the Drive Cables section in this table.
PCIe/NVMe SFF (2.5-inch) SFF drives
UCS-NVMEXP-I400-D= 400GB 2.5in U.2 Intel P5800X Optane NVMe Extreme Perform SSD
UCS-NVMEXP-I800-D= 800GB 2.5in U.2 Intel P5800X Optane NVMe Extreme Perform SSD
UCS-NVME4-1600-D= 1.6TB 2.5in U.2 P5620 NVMe High Perf High Endurance
UCS-NVME4-1920-D= 1.9TB 2.5in U.2 P5520 NVMe High Perf Medium Endurance
UCS-NVME4-3200-D= 3.2TB 2.5in U.2 P5620 NVMe High Perf High Endurance
UCS-NVME4-3840-D= 3.8TB 2.5in U.2 P5520 NVMe High Perf Medium Endurance
UCS-NVME4-6400-D= 6.4TB 2.5in U.2 P5620 NVMe High Perf High Endurance
UCS-NVME4-7680-D= 7.6TB 2.5in U.2 P5520 NVMe High Perf Medium Endurance
UCS-NVME4-15360-D= 15.3TB 2.5in U.2 P5520 NVMe High Perf Medium Endurance
UCS-NVMEQ-1536-D= 15.3TB 2.5in U.2 P5316 NVMe High Perf Low Endurance
UCS-NVMEG4-M960-D= 960GB 2.5in U.3 Micron P7450 NVMe High Perf Medium Endurance
UCS-NVMEG4-M1920D= 1.9TB 2.5in U.3 Micron P7450 NVMe High Perf Medium Endurance
UCS-NVMEG4-M3840D= 3.8TB 2.5in U.3 Micron P7450 NVMe High Perf Medium Endurance
UCS-NVMEG4-M7680D= 7.6TB 2.5in U.3 Micron P7450 NVMe High Perf Medium Endurance
UCS-NVMEG4-M1536D= 15.3TB 2.5in U.3 MicronP7450 NVMe High Perf Medium Endurance
UCS-NVMEG4-M1600D= 1.6TB 2.5in U.3 Micron P7450 NVMe High Perf High Endurance
UCS-NVMEG4-M3200D= 3.2TB 2.5in U.3 Micron P7450 NVMe High Perf High Endurance
UCS-NVMEG4-M6400D= 6.4TB 2.5in U.3 Micron P7450 NVMe High Perf High Endurance
HDDs
HDDs (10K RPM)
UCS-HD600G10KJ4-D= 600 GB 12G SAS 10K RPM SFF HDD
UCS-HD12TB10KJ4-D= 1.2 TB 12G SAS 10K RPM SFF HDD
UCS-HD18TB10KJ4-D= 1.8 TB 12G SAS 10K RPM SFF HDD (4K)
UCS-HD24TB10KJ4-D= 2.4 TB 12G SAS 10K RPM SFF HDD (4K)
Enterprise Performance SAS/SATA SSDs (High endurance, supports up to 10X or 3X DWPD (drive
writes per day))
SATA
UCS-SD480G63XEP-D= 480 GB 2.5in Enterprise Performance 6G SATA SSD(3X endurance)
UCS-SD960G63XEP-D= 960 GB 2.5in Enterprise performance 6G SATA SSD(3X endurance)
UCS-SD19T63X-EP-D= 1.9 TB 2.5in Enterprise performance 6G SATA SSD(3X endurance)
UCS-SD38T63X-EP-D= 3.8 TB 2.5in Enterprise performance 6G SATA SSD(3X endurance)
UCS-SD480GBM3XEPD= 480GB SATA SSD 3DWPD
UCS-SD960GBM3XEPD= 960GB SATA SSD 3DWPD
UCS-SD19TBM3XEP-D= 1.9TB SATA SSD 3DWPD
73 Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model)
SPARE PARTS
Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model) 74
SPARE PARTS
75 Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model)
SPARE PARTS
Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model) 76
SPARE PARTS
77 Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model)
SPARE PARTS
Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model) 78
SPARE PARTS
79 Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model)
SPARE PARTS
Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model) 80
TECHNICAL SPECIFICATIONS
TECHNICAL SPECIFICATIONS
Dimensions and Weight
Parameter Value
Weight
81 Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model)
TECHNICAL SPECIFICATIONS
Power Specifications
The server is available with the following types of power supplies:
Parameter Specification
Input Connector IEC320 C14
Input Voltage Range (Vrms) 100 to 240
Maximum Allowable Input Voltage Range (Vrms) 90 to 264
Frequency Range (Hz) 50 to 60
Maximum Allowable Frequency Range (Hz) 47 to 63
Maximum Rated Output (W) 770
Maximum Rated Standby Output (W) 36
Nominal Input Voltage (Vrms) 100 120 208 230
Nominal Input Current (Arms) 8.8 7.4 4.2 3.8
Maximum Input at Nominal Input Voltage (W) 855 855 855 846
Maximum Input at Nominal Input Voltage (VA) 882 882 882 872
Minimum Rated Efficiency (%)1 90 90 90 91
Minimum Rated Power Factor1 0.97 0.97 0.97 0.97
Maximum Inrush Current (A peak) 15
Maximum Inrush Current (ms) 0.2
Minimum Ride-Through Time (ms)2 12
Notes:
1. This is the minimum rating required to achieve 80 PLUS Platinum certification, see test reports published at
http://www.80plus.org/ for certified values
2. Time output voltage remains within regulation limits at 100% load, during input voltage dropout
Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model) 82
TECHNICAL SPECIFICATIONS
Parameter Specification
Input Connector Molex 42820
Input Voltage Range (V rms) -48
Maximum Allowable Input Voltage Range (V rms) -40 to -72
Frequency Range (Hz) NA
Maximum Allowable Frequency Range (Hz) NA
Maximum Rated Output (W) 1050
Maximum Rated Standby Output (W) 36
Nominal Input Voltage (V rms) -48
Nominal Input Current (A rms) 24
Maximum Input at Nominal Input Voltage (W) 1154
Maximum Input at Nominal Input Voltage (VA) 1154
Minimum Rated Efficiency (%)1 91
Minimum Rated Power Factor1 NA
Maximum Inrush Current (A peak) 15
Maximum Inrush Current (ms) 0.2
Minimum Ride-Through Time (ms)2 5
Notes:
1. This is the minimum rating required to achieve 80 PLUS Platinum certification, see test reports published at
http://www.80plus.org/ for certified values
2. Time output voltage remains within regulation limits at 100% load, during input voltage dropout
83 Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model)
TECHNICAL SPECIFICATIONS
Parameter Specification
Input Connector IEC320 C14
Input Voltage Range (Vrms) 100 to 240
Maximum Allowable Input Voltage Range (Vrms) 90 to 264
Frequency Range (Hz) 50 to 60
Maximum Allowable Frequency Range (Hz) 47 to 63
Maximum Rated Output (W)1 1100 1200
Maximum Rated Standby Output (W) 48
Nominal Input Voltage (Vrms) 100 120 208 230
Nominal Input Current (Arms) 12.97 10.62 6.47 5.84
Maximum Input at Nominal Input Voltage (W) 1300 1264 1343 1340
Maximum Input at Nominal Input Voltage (VA) 1300 1266 1345 1342
Minimum Rated Efficiency (%)2 90 90 91 91
Minimum Rated Power Factor2 0.97 0.97 0.97 0.97
Maximum Inrush Current (A peak) 20
Maximum Inrush Current (ms) 0.2
Minimum Ride-Through Time (ms)3 12
Notes:
1. Maximum rated output is limited to 1100W when operating at low-line input voltage (100-127V)
2. This is the minimum rating required to achieve 80 PLUS Titanium certification, see test reports published at
http://www.80plus.org/ for certified values
3. Time output voltage remains within regulation limits at 100% load, during input voltage dropout
Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model) 84
TECHNICAL SPECIFICATIONS
Parameter Specification
Input Connector IEC320 C14
Input Voltage Range (V rms) 200 to 240
Maximum Allowable Input Voltage Range (V rms) 180 to 264
Frequency Range (Hz) 50 to 60
Maximum Allowable Frequency Range (Hz) 47 to 63
Maximum Rated Output (W) 1600
Maximum Rated Standby Output (W) 36
Nominal Input Voltage (V rms) 100 120 208 230
Nominal Input Current (A rms) NA NA 8.8 7.9
Maximum Input at Nominal Input Voltage (W) NA NA 1778 1758
Maximum Input at Nominal Input Voltage (VA) NA NA 1833 1813
Minimum Rated Efficiency (%)1 NA NA 90 91
Minimum Rated Power Factor2 NA NA 0.97 0.97
Maximum Inrush Current (A peak) 30
Maximum Inrush Current (ms) 0.2
Minimum Ride-Through Time (ms)2 12
Notes:
1. This is the minimum rating required to achieve 80 PLUS Platinum certification, see test reports published at
http://www.80plus.org/ for certified values
2. Time output voltage remains within regulation limits at 100% load, during input voltage dropout
85 Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model)
TECHNICAL SPECIFICATIONS
Parameter Specification
Input Connector IEC320 C20
Input Voltage Range (Vrms) 100 to 240
Maximum Allowable Input Voltage Range (Vrms) 90 to 264
Frequency Range (Hz) 50 to 60
Maximum Allowable Frequency Range (Hz) 47 to 63
Maximum Rated Output (W)1 2300
Maximum Rated Standby Output (W) 36
Nominal Input Voltage (Vrms) 100 120 208 230
Nominal Input Current (Arms) 13 11 12 10.8
Maximum Input at Nominal Input Voltage (W) 1338 1330 2490 2480
Maximum Input at Nominal Input Voltage (VA) 1351 1343 2515 2505
Minimum Rated Efficiency (%)2 92 92 93 93
Minimum Rated Power Factor2 0.99 0.99 0.97 0.97
Maximum Inrush Current (A peak) 30
Maximum Inrush Current (ms) 0.2
Minimum Ride-Through Time (ms)3 12
Notes:
1. Maximum rated output is limited to 1200W when operating at low-line input voltage (100-127V)
2. This is the minimum rating required to achieve 80 PLUS Titanium certification, see test reports published at
http://www.80plus.org/ for certified values
3. Time output voltage remains within regulation limits at 100% load, during input voltage dropout
NOTE: For configuration-specific power specifications, use the Cisco UCS Power
Calculator at this URL: http://ucspowercalc.cisco.com
Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model) 86
TECHNICAL SPECIFICATIONS
Environmental Specifications
The environmental specifications for Cisco UCS C220 M7 SFF server are listed in Table 45.
Parameter Minimum
Operating Temperature 5°C to 35°C (supports ASHRAE Class A4 and/or Class A3 and/or
Class A2)
ASHRAE Class A3 will be generic test profile unless otherwise
specified by product engineering.
System shall continue to operate with a single fan failure (one
failed impeller in dual impeller housings) across the ASHRAE
recommended operating range of 18 °C to 27 °C. While
undesired, increased power consumption and/or acoustic noise
is permitted during a fan fail event.
Non-Operating Temperature Dry bulb temperature of -40°C to 65°C (-40°F to 149°F)
Operating Relative Humidity 8% to 90% relative humidity, non-condensing, with maximum wet
bulb 28°C (82.4°F) within operational temperature range of 5°C
to 50°C (41°F to 122°F)
Non-Operating Relative Humidity 5% to 93% relative humidity, non-condensing, with a maximum
wet bulb temperature of 28°C across the 20°C to 40°C dry bulb
range.
Maximum Operating Duration Unlimited
Operating Altitude A maximum elevation of 3050 meters (10,006 ft)
Non-Operating Altitude An elevation of 0 to 12,000 meters (39,370 ft)
Sound Power level, Measure 1RU: 5.5B
A-weighted per ISO7779 LWAd (Bels) 2RU: 5.8B
Operation at 23°C (73°F)
Racked product: 6.8B
Sound Pressure level, Measure 1RU: 40dB
A-weighted per ISO7779 LpAm (dBA)
2RU: 43dB
Operation at 23°C (73°F)
Racked product: 55dB
87 Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model)
TECHNICAL SPECIFICATIONS
Compliance Requirements
The regulatory compliance requirements for C-Series servers are listed in Table 46.
Parameter Description
Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model) 88
DISCONTINUED EOL PRODUCTS
Table 47 EOS
Product ID Description EOL/EOS link
Drives
UCS-M2-240GB-D 240GB M.2 SATA Micron G1 SSD https://www.cisco.com/c/en/us/products/collate
ral/servers-unified-computing/ucs-c-series-rack-se
rvers/unified-computing-accessories-eol.html
UCS-M2-960GB-D 960GB M.2 SATA Micron G1 SSD https://www.cisco.com/c/en/us/products/collate
ral/servers-unified-computing/ucs-c-series-rack-se
rvers/unified-computing-accessories-eol.html
UCS-SD240GM1XEV-D 240GB 2.5in Enter Value 6G SATA https://www.cisco.com/c/en/us/products/collate
Micron G1 SSD ral/servers-unified-computing/ucs-c-series-rack-se
rvers/unified-computing-accessories-eol.html
UCS-SD76TM1X-EV-D 7.6TB 2.5in Enter Value 6G SATA https://www.cisco.com/c/en/us/products/collate
Micron G1 SSD ral/servers-unified-computing/ucs-c-series-rack-se
rvers/unified-computing-accessories-eol.html
UCS-SD480GM1XEV-D 480 GB 2.5in Enter Value 6G SATA https://www.cisco.com/c/en/us/products/collate
Micron G1 SSD ral/servers-unified-computing/ucs-c-series-rack-se
rvers/unified-computing-accessories-eol.html
UCSSD76TBEM2NK9-D 7.6TB 2.5in Enter Value 6G SATA https://www.cisco.com/c/en/us/products/collate
Micron G1 SSD (SED) ral/servers-unified-computing/ucs-c-series-rack-se
rvers/unified-computing-accessories-eol.html
UCSSD960GBM2NK9-D 960GB 2.5in Enter Value 6G SATA https://www.cisco.com/c/en/us/products/collate
Micron G1 SSD (SED) ral/servers-unified-computing/ucs-c-series-rack-se
rvers/unified-computing-accessories-eol.html
UCS-SD16TM1X-EV-D 1.6TB 2.5in Enter Value 6G SATA https://www.cisco.com/c/en/us/products/collate
Micron G1 SSD ral/servers-unified-computing/ucs-c-series-rack-se
rvers/unified-computing-accessories-eol.html
UCS-SD38TM1X-EV-D 3.8TB 2.5in Enter Value 6G SATA https://www.cisco.com/c/en/us/products/collate
Micron G1 SSD ral/servers-unified-computing/ucs-c-series-rack-se
rvers/unified-computing-accessories-eol.html
89 Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model)