c220m7 SFF Specsheet

Download as pdf or txt
Download as pdf or txt
You are on page 1of 90

Spec Sheet

Cisco UCS C220 M7 SFF


Rack Server
A printed version of this document is only a copy
and not necessarily the latest version. Refer to
the following link for the latest released version:
https://www.cisco.com/c/en/us/products/servers-unified-
computing/ucs-c-series-rack-servers/datasheet-
listing.html

CISCO SYSTEMS PUBLICATION HISTORY


170 WEST TASMAN DR
SAN JOSE, CA, 95134 REV A.38 MAY 10, 2024
WWW.CISCO.COM
CONTENTS

OVERVIEW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
DETAILED VIEWS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Detailed Chassis Front View . . .... ... .... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Detailed Chassis Rear Views . . .... ... .... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
One Half-Height Riser . . .... ... .... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Three Half-Height Risers .... ... .... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Two Full-Height Risers . .... ... .... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
BASE SERVER STANDARD CAPABILITIES and FEATURES . . . . . . . . . . . . . . . . 10
CONFIGURING the SERVER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
STEP 1 SELECT SERVER SKU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
STEP 2 SELECT RISERS (REQUIRED) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
STEP 3 SELECT CPU(s) (REQUIRED) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
STEP 4 SELECT MEMORY (REQUIRED) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Memory configurations and mixing rules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
STEP 5 SELECT DRIVE CONTROLLERS (OPTIONAL) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
RAID Volumes and Groups . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
STEP 6 SELECT DRIVES (OPTIONAL) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
STEP 7 SELECT OPTION CARD(s) (OPTIONAL) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
ORDER OPTIONAL PCIe OPTION CARD ACCESSORIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
STEP 8 ORDER GPU CARDS (OPTIONAL) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
STEP 9 ORDER POWER SUPPLY (REQUIRED) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
STEP 10 SELECT INPUT POWER CORD(s) (REQUIRED) . . . . . . . . . . . . . . . . . . . . . . . . . . 43
STEP 11 ORDER TOOL-LESS RAIL KIT (REQUIRED) AND REVERSIBLE CABLE MANAGEMENT ARM (OPTIONAL)
47
STEP 12 SELECT MANAGEMENT CONFIGURATION (OPTIONAL) . . . . . . . . . . . . . . . . . . . . 48
STEP 13 ORDER SECURITY DEVICES (REQUIRED) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
STEP 14 SELECT LOCKING SECURITY BEZEL (OPTIONAL) . . . . . . . . . . . . . . . . . . . . . . . . 50
STEP 15 ORDER M.2 SATA SSDs (OPTIONAL) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
STEP 16 ORDER M.2 NVMe AND RAID CONTROLLER(OPTIONAL) . . . . . . . . . . . . . . . . . . . . 52
STEP 17 SELECT OPERATING SYSTEM AND VALUE-ADDED SOFTWARE . . . . . . . . . . . . . . . . 53
STEP 18 CHOOSE OPTIONAL OPERATING SYSTEM MEDIA KIT . . . . . . . . . . . . . . . . . . . . . . 57
SUPPLEMENTAL MATERIAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
Block Diagrams . . . .... ... .... ... .... .... ... .... ... .... .... ... .... . . 58
Chassis . . . . . . . . . .... ... .... ... .... .... ... .... ... .... .... ... .... . . 60
Risers . . . . . . . . . .... ... .... ... .... .... ... .... ... .... .... ... .... . . 62
Serial Port Details . .... ... .... ... .... .... ... .... ... .... .... ... .... . . 65
KVM Cable . . . . . . .... ... .... ... .... .... ... .... ... .... .... ... .... . . 65
UPGRADING or REPLACING CPUs and Memory . . . . . . . . . . . . . . . . . . . . . . 66
SPARE PARTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
TECHNICAL SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80
Dimensions and Weight . . . . . . . . . . . . . . . . . . . . . . . .... ... .... .... ... .... . . 80
Power Specifications . . . . . . . . . . . . . . . . . . . . . . . . .... ... .... .... ... .... . . 81
Environmental Specifications . . . . . . . . . . . . . . . . . . . .... ... .... .... ... .... . . 86
Compliance Requirements . . . . . . . . . . . . . . . . . . . . . .... ... .... .... ... .... . . 87
DISCONTINUED EOL PRODUCTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88

1 Cisco UCS C220 M7 Rack Server (Small Factor Disk Drive Model)
OVERVIEW

OVERVIEW
The Cisco UCS C220 M7 SFF server extends the capabilities of Cisco’s Unified Computing System portfolio in
a 1U form factor with the 5th Gen. Intel® Xeon® Scalable Processors, 16 DIMM slots per CPU for DDR5-5600
Memory DIMMs with DIMM capacity points up to 128GB or 4th Gen. Intel® Xeon® Scalable Processors, 16 DIMM
slots per CPU for DDR5-4800 Memory DIMMs with DIMM capacity points up to 128GB.

The Cisco UCS C220 M7 server harnesses the power of the latest Intel® Xeon® Scalable Processors and offers
the following:

CPU:

■ Up to 2x 5th Generation Intel® Xeon® Scalable Processors with up to 60 cores per processor or
■ Up to 2x 4th Generation Intel® Xeon® Scalable Processors with up to 52 cores per processor.

Memory:

■ Up to 4TB with 32 x 128GB DDR5-5600 DIMMs, in a 2-socket configuration with 5th Gen. Intel® Xeon®
Scalable Processors or
■ Up to 4TB with 32 x 128GB DDR5-4800 DIMMs, in a 2-socket configuration with 4th Gen. Intel® Xeon®
Scalable Processors.

The server provides an internal slot for one of the following:

■ SATA Interposer to control SATA drives from the PCH (AHCI) or


■ Cisco 24G Tri-mode RAID controller with cache backup to control SAS/SATA/NVMe drives or
■ Cisco 12G RAID controller with cache backup to control SAS/SATA drives or
■ Cisco 12G SAS pass-through HBA to control SAS/SATA drives

mLOM: The UCS C220 M7 SFF server has a single 1GBE management port. A modular LAN on motherboard
(mLOM)/OCP 3.0 module provides up to two 100GBE ports. A connector on the front of the chassis provides
KVM functionality.

There are several options to choose from:

■ Option 1 UCSC-C220-M7S (see Figure 1 on page 3):


■ Drive bays 1-10 supports up to 10 front facing SFF SAS/SATA HDDs/SSDs or NVMe SSDs with
hardware raid (optionally up to 4 of the slots can be direct-attach NVMe).
■ One to three half-height PCIe risers or one to two full-height PCIe risers
■ Option 2 UCSC-C220-M7N (see Figure 1 on page 3):
■ Drive bays 1 - 10 support only NVMe PCIe drives.
■ One to three half-height PCIe risers, or one to two full-height PCIe risers

The Cisco UCS C220 M7 SFF server can be used standalone, or as part of the Cisco Unified Computing
System, which unifies computing, networking, management, virtualization, and storage access into a single
integrated architecture, enabling end-to-end server visibility, management, and control in both bare metal
and virtualized environments.

See Figure 1 on page 3 for front and rear views of the UCS C220 M7 server.

Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model) 2
OVERVIEW

Figure 1 Cisco UCS C220 M7 SFF Rack Server

Front View

Rear View (one half-height riser card version)

Rear View (three half-height riser card version)

Rear View (two full-height riser card version - shown with riser blanks installed)

3 Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model)
DETAILED VIEWS

DETAILED VIEWS
Detailed Chassis Front View
Figure 2 shows the detailed front view of the Cisco UCS C220 M7 SFF Rack Server

Figure 2 Detailed Chassis Front View

1-4 Option 1 UCSC-C220-M7S 15 System status LED


■ Drive bays 1 – 4 support SAS/SATA hard
drives and solid state drives (SSDs) or
NVMe PCIe drives.1,2
Option 2 UCSC-C220-M7N
■ Drive bays 1 – 4 support only NVMe PCIe
drives

5 - 10 Option 1 UCSC-C220-M7S 16 Fan status LED


■ Drive bays 5 - 10 support SAS/SATA hard
drives and solid state drives (SSDs) only
Option 2 UCSC-C220-M7N3
■ Drive bays 5 - 10 support NVMe PCIe
drives only.

11 Asset tag location 17 Temperature status LED

12 Control panel 18 Network link activity LED

13 Power button/power status LED 19 Power supply status LED

14 Unit Identification button/LED 20 KVM connector (used with KVM cable that
provides two USB 2.0, one VGA, and one
serial connector)

Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model) 4
DETAILED VIEWS

Notes:
1. You can mix and match in drive bays 1 - 4. For example, slots 1 and 2 can hold NVMe drives and slots 3 and 4
can hold SAS/SATA HDDs or SSDs.
2. If using a SATA Interposer board, up to a maximum of 8 SATA-only drives can be configured (slots 1-4 and 6-9
only)

Detailed Chassis Rear Views


Figure 3 shows the details of the rear panel for the UCS C220 M7 with one rear half-height PCIe riser.

Figure 4 shows the details of the rear panel for the UCS C220 M7 with three rear half-height PCIe risers.

Figure 5 shows the details of the rear panel for the UCS C220 M7 with two rear full-height PCIe risers.

5 Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model)
DETAILED VIEWS

One Half-Height Riser

NOTE: 1-CPU servers support 1 and 2 half-height risers. 2-CPU servers support all three
half-height risers.

Figure 3 Chassis Rear View (one half-height, 3/4 length PCIe riser)

1 There are two half height riser 1 options: 6 System ID pushbutton/LED


Riser 1A PCIe Gen4 (CPU1 control)
■ Supports one PCIe slot (slot 1)
■ Slot 1 is half-height, 3/4 length, x16, NCSI,
Single Wide GPU
Riser 1B PCIe Gen5 (CPU1 control)
■ Supports one PCIe slot (slot 1)
■ Slot 1 is half-height, 3/4 length, x16, NCSI,
Single Wide GPU
2 Riser 2 blanking panel 7 VGA display port (DB15 connector)
3 Riser 3 blanking panel 8 COM port (RJ45 connector)
4 Power supplies (two, redundant as 1+1) 9 1GBE dedicated Ethernet management
port
5 Modular LAN on motherboard (mLOM)/OCP 3.0 slot 10 USB 3.0 ports (two)

Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model) 6
DETAILED VIEWS

Three Half-Height Risers

NOTE:
■ Only 2-CPU servers support all three half-height risers.
■ Gen4 and Gen5 risers cannot be mixed.

Figure 4 Chassis Rear View (three half-height, 3/4 length PCIe risers)

1 There are two half height riser 1 options: 6 System ID pushbutton/LED


Riser 1A PCIe Gen4 (CPU1 control)
■ Supports one PCIe slot (slot 1)
■ Slot 1 is half-height, 3/4 length, x16,
NCSI, Single Wide GPU
Riser 1B PCIe Gen5 (CPU1 control)
■ Supports one PCIe slot (slot 1)
■ Slot 1 is half-height, 3/4 length, x16,
NCSI, Single Wide GPU
2 There are two half height riser 2 options: 7 VGA display port (DB15 connector)
Riser 2A PCIe Gen4 x16 (CPU1 control)
■ Supports one PCIe slot (slot 2)
■ Slot 2 is half-height, 3/4 length, x16,
Single Wide GPU
Riser 2B PCIe Gen5 x16 (CPU1 control)
■ Supports one PCIe slot (slot 2)
■ Slot 2 is half-height, 3/4 length, x16,
Single Wide GPU

7 Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model)
DETAILED VIEWS

3 There is one half height riser 3 option: 8 COM port (RJ45 connector)
Riser 3A PCIe Gen4 x16 (CPU2 control)
■ Supports one PCIe slot (slot 3)
■ Slot 3 is half-height, 3/4 length, x16,
NCSI, Single Wide GPU
4 Power supplies (two, redundant as 1+1) 9 1GBE dedicated Ethernet management
port
5 Modular LAN on motherboard (mLOM)/OCP 10 USB 3.0 ports (two)
3.0 slot

Two Full-Height Risers

NOTE: 1-CPU servers support only full-height riser 1 while 2-CPU servers support both full-height
risers.

Figure 5 Chassis Rear View (two full-height, 3/4-length PCIe risers)

Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model) 8
DETAILED VIEWS

1 Riser 1C PCIe Gen5 (CPU1 control) 6 VGA display port (DB15 connector)
■ Supports one PCIe slot (slot 1)
■ Slot 1 is full-height, 3/4 length,
x16,NCSI, Single Wide GPU

2 Riser 3C PCIe Gen5 x16 (CPU2 control) 7 COM port (RJ45 connector)
■ Supports one PCIe slot (slot 3)
■ Slot 3 is Full-height, 3/4 length, x16,
NCSI, Single Wide GPU

3 Power supplies (two, redundant as 1+1) 8 1GBE dedicated Ethernet management port

4 Modular LAN on motherboard (mLOM)/OCP 9 USB 3.0 ports (two)


3.0 slot

5 System ID pushbutton/LED - -

9 Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model)
BASE SERVER STANDARD CAPABILITIES and FEATURES

BASE SERVER STANDARD CAPABILITIES and FEATURES


Table 1 lists the capabilities and features of the base server. Details about how to configure the server for
a particular feature or capability (for example, number of processors, disk drives, or amount of memory)
are provided in CONFIGURING the SERVER, page 14.

Table 1 Capabilities and Features

Capability/Feature Description
Chassis One rack unit (1RU) chassis
CPU ■ One or two 5th Gen. Intel® Xeon® Scalable Processors or One or two 4th
Gen. Intel® Xeon® Scalable Processors.
■ Each CPU has 8 channels with up to 2 DIMMs per channel, for up to 16
DIMMs per CPU
■ UPI Links: Up to 3 at 20GT/s
Chipset Intel® C741 series chipset
Memory ■ 32 total DDR5-5600 MT/s DIMM slots with 5th Gen. Intel® Xeon® Scalable
Processors (16 per CPU) or 32 total DDR5-4800 MT/s DIMM slots with 4th
Gen. Intel® Xeon® Scalable Processors
■ Up to 4TB DDR5-5600 DIMM memory capacity (32x 128GB DIMMs) with 5th
Gen. Intel® Xeon® Scalable Processors or Up to 4TB DDR5-4800 DIMM
memory capacity (32x 128GB DIMMs) with 4th Gen. Intel® Xeon® Scalable
Processors
■ Up to 75% peak bandwidth increase over DDR4-3200, with on-die ECC; all
densities are Registered DIMMs (RDIMMs)
Video The Cisco Integrated Management Controller (CIMC) provides video using the
Matrox G200e video/graphics controller:

■ Integrated 2D graphics core with hardware acceleration


■ Embedded DDR memory interface supports up to 512 MB of addressable
memory (8 MB is allocated by default to video memory)
■ Supports display resolutions up to 1920 x 1200 16bpp @ 60Hz
■ High-speed integrated 24-bit RAMDAC
■ Single lane PCI-Express host interface running at Gen 1 speed
Power subsystem Up to two of the following hot-swappable power supplies:
■ 770 W (AC)
■ 1200W (AC)
■ 1600 W (AC)
■ 2300 W (AC)
One power supply is mandatory; one more can be added for 1 + 1 redundancy.
Front Panel A front panel controller provides status indications and control buttons
ACPI This server supports the advanced configuration and power interface (ACPI) 6.2
standard.
Fans Eight hot-swappable fans for front-to-rear cooling
Infiniband The InfiniBand architecture is supported by the PCI slots.

Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model) 10
BASE SERVER STANDARD CAPABILITIES and FEATURES

Table 1 Capabilities and Features (continued)

Capability/Feature Description
Expansion slots ■ Half-height riser slots (select up to three)
• Riser 1A PCIe Gen4 x16 HH
• Riser 1B PCIe Gen5 x16 HH
• Riser 2A PCIe Gen4 x16 HH
• Riser 2B PCIe Gen5 x16 HH
• Riser 3A PCIe Gen4 x16 HH (CPU2 Control)
■ Full-height riser slots (select up to two)
• Riser 1C PCIe Gen5 x16 FH
• Riser 3C PCIe Gen5 x16 FH (CPU2 Control)
Interfaces ■ Rear panel

• One 1Gbase-T RJ-45 management port


• One RS-232 serial port (RJ45 connector)
• One DB15 VGA connector
• Two USB 3.0 port connectors
• One flexible modular LAN on motherboard (mLOM/OCP 3.0) slot that
can accommodate various interface cards
■ Front panel
• One KVM console connector (supplies two USB 2.0 connectors, one VGA
DB15 video connector, and one serial port (RS232) RJ45 connector)
Integrated management Baseboard Management Controller (BMC) running Cisco Integrated Management
processor Controller (CIMC) firmware.
Depending on your CIMC settings, the CIMC can be accessed through the 1GE
dedicated management port. Cisco virtual interface card (VIC).
CIMC manages certain components within the server, such as the Cisco 12G SAS
HBA.

11 Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model)
BASE SERVER STANDARD CAPABILITIES and FEATURES

Table 1 Capabilities and Features (continued)

Capability/Feature Description
Internal storage devices Drive storage:
Drives are installed into front-panel drive bays, which provide hot-swappable
access for SAS/SATA or NVMe drives. The server is orderable in two different
versions:
■ UCSC-C220-M7S (option 1):
• Up to 10 SFF SAS/SATA hard drives (HDDs) or SAS/SATA/NVMe solid state
drives (SSDs).
• Optionally, up to four direct-attach SFF NVMe PCIe SSDs. These drives
must be placed in front drive bays 1, 2, 3, and 4 only, can be mixed
with SAS/SATA drives, and are controlled from CPU 2. The rest of the
bays (5 - 10) can be populated with SAS/SATA/NVMe SSDs or HDDs. Two
CPUs are required when choosing direct-attach NVMe SSDs.
• If using a SATA Interposer, up to 8 SATA-only drives can be installed
(slots 1-4 and 6-9 only).
■ UCSC-C220-M7N (option 2):
• Up to 10 2.5-inch direct-attach NVMe SSDs. only.
• The drives in slots 1, 2, 3, 4, 6, and 7 are connected to CPU 2 and the
drives in slots 5, 8, 9, and 10 are connected to CPU1. Up to 4 drives are
allowed with single CPU configuration and can only be installed in slots
5, 8, 9, and 10.
Other storage:
■ A mini-storage module connector on the motherboard supports a
boot-optimized RAID controller carrier that holds up to two SATA M.2 SSDs.
■ 8GB FlexMMC utility storage for staging of firmware and other user data.
8GB FlexMMC storage is built into the motherboard on M7.

Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model) 12
BASE SERVER STANDARD CAPABILITIES and FEATURES

Table 1 Capabilities and Features (continued)

Capability/Feature Description
Storage controllers Internal storage controllers:
The SATA Interposer board, 24G Tri-mode RAID controller, 12G RAID controller
or 12G SAS HBA. Only one of these at a time can be used.
■ SATA Interposer board
• AHCI support up to eight SATA-only drives (slots 1-8)
■ Cisco 24G Tri-mode RAID controller
• RAID support (RAID 0, 1, 5, 6, 10, 50, 60, RAID0, and RAID00)
• Supports up to 10 internal SAS/SATA/NVMe drives
■ Cisco 12G RAID controller
• RAID support (RAID 0, 1, 5, 6, 10, 50, 60, RAID0, and RAID00)
• Supports up to 10 internal SAS/SATA drives
■ Cisco 12G SAS HBA
• No RAID support
• JBOD/Pass-through Mode support
• Supports up to 10 SAS/SATA internal drives
External storage controllers:
■ Cisco 12G 9500-8e 12G SAS HBA for external JBOD attach
Modular LAN on The dedicated mLOM/Open Compute Project (OCP) 3.0 slot on the motherboard
Motherboard (mLOM)/ can flexibly accommodate the following cards:
Open Compute Project
(OCP) 3.0 slot ■ Cisco Virtual Interface Cards
■ Open Compute Project (OCP) 3.0 network interface card
Fabric Interconnect Compatible with the Cisco UCS 6454, 64108 and 6536 fabric interconnects
UCSM1 UCS Manager (UCSM) 4.3(2) or later runs in the Fabric Interconnect and
automatically discovers and provisions some of the server components.
CIMC Cisco Integrated Management Controller 4.3(1) or later
Intersight Intersight provides server management capabilities
Firmware standards UEFI Spec 2.9
ACPI 6.5
SMBIOS Ver 3.6

13 Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER

CONFIGURING the SERVER


Follow these steps to configure the Cisco UCS C220 M7 SFF Rack Server:

■ STEP 1 SELECT SERVER SKU, page 15


■ STEP 2 SELECT RISERS (REQUIRED), page 16
■ STEP 3 SELECT CPU(s) (REQUIRED), page 18
■ STEP 4 SELECT MEMORY (REQUIRED), page 23
■ STEP 5 SELECT DRIVE CONTROLLERS (OPTIONAL), page 30
■ STEP 6 SELECT DRIVES (OPTIONAL), page 34
■ STEP 7 SELECT OPTION CARD(s) (OPTIONAL), page 38
■ STEP 8 ORDER GPU CARDS (OPTIONAL), page 41
■ STEP 9 ORDER POWER SUPPLY (REQUIRED), page 42
■ STEP 10 SELECT INPUT POWER CORD(s) (REQUIRED), page 43
■ STEP 11 ORDER TOOL-LESS RAIL KIT (REQUIRED) AND REVERSIBLE CABLE MANAGEMENT ARM
(OPTIONAL), page 47
■ STEP 12 SELECT MANAGEMENT CONFIGURATION (OPTIONAL), page 48
■ STEP 13 ORDER SECURITY DEVICES (REQUIRED), page 49
■ STEP 14 SELECT LOCKING SECURITY BEZEL (OPTIONAL), page 50
■ STEP 15 ORDER M.2 SATA SSDs (OPTIONAL), page 51
■ STEP 16 ORDER M.2 NVMe AND RAID CONTROLLER(OPTIONAL), page 52
■ STEP 18 CHOOSE OPTIONAL OPERATING SYSTEM MEDIA KIT, page 57
■ SUPPLEMENTAL MATERIAL, page 58

Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model) 14
CONFIGURING the SERVER

STEP 1 SELECT SERVER SKU


Top level ordering product ID (PID) is shown inTable 2.
Table 2 Top level ordering PID (Major Line Bundle)

Product ID (PID) Description

UCS-M7-MLB UCS M7 RACK, BLADE MLB


This major line bundle (MLB) consists of the Rack Server (UCSC-C220-M7S or
UCSC-C220-M7N) with software PIDs. Use this PID to begin a new configuration.

Select one product ID (PID) as shown in Table 3.

CAUTION: This product may not be purchased outside of the approved bundles (must be
ordered under the MLB)

Table 3 PID of the C220 M7 SFF Rack Base Server

Product ID (PID) Description


UCSC-C220-M7S Small form-factor (SFF) drives, with 10-drive backplane.
(option 1) ■ Front facing drive bays 1-10 support 2.5in SAS/SATA/NVMe SSDs depending
on controller type installed.
■ Optionally, front-loading drive bays 1, 2, 3, and 4 support 2.5-inch
direct-attach NVMe SSDs and the rest can be SAS/SATA HDDs or SSDs.
UCSC-C220-M7N Small form-factor (SFF) drives, with 10-drive backplane.
(option 2) ■ Front-loading drive bays 1—10 support 2.5-inch NVMe SSDs (only) drives.

The Cisco UCS C220 M7 SFF Server:

■ Includes a 10 drive backplane.


■ Does not include power supply, CPU, memory, hard disk drives (HDDs), solid-state drives
(SSDs), NVMe drives, SD cards, riser 1, riser 2, riser 3, tool-less rail kit, or PCIe cards.
■ Use the steps on the following pages to configure the server with the components that you
want to include.

15 Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER

STEP 2 SELECT RISERS (REQUIRED)


The riser PIDs are listed in Table 4.

CAUTION:
■ Full-height risers cannot be mixed with half-height risers.
■ Gen4 and Gen5 risers cannot be mixed.

Table 4 PIDs of the Risers and Riser Blanks

Product ID (PID) Description


Riser 1 Option
UCSC-RIS1A-22XM7 UCS C-Series M7 1U Riser 1A PCIe Gen4 x16 HH
■ Half-height riser 1 (controlled by CPU 1)
■ One x16 PCIe Gen4 riser, standard PCIe, supports Cisco VIC, half-height, 3/4 length
UCSC-RIS1B-22XM7 UCS C-Series M7 1U Riser 1B PCIe Gen5 x16 HH
■ Half-height riser 1 (controlled by CPU 1)
■One x16 PCIe Gen5 riser, standard PCIe, supports Cisco VIC, half-height, 3/4 length
UCSC-RIS1C-22XM7 UCS C-Series M7 1U Riser 1C PCIe Gen5 x16 FH
■ Full-height riser 1 (controlled by CPU 1)
■ One x16 PCIe Gen5 riser, standard PCIe, supports Cisco VIC, full-height, 3/4 length
Riser 2 Option
UCSC-RIS2A-22XM7 UCS C-Series M7 1U Riser 2A PCIe Gen4 x16 HH
■ Half-height riser 2 (controlled by CPU 1)
■ One x16 PCIe Gen4 riser, standard PCIe, half-height, 3/4 length
UCSC-RIS2B-22XM7 UCS C-Series M7 1U Riser 2B PCIe Gen5 x16 HH
■ Half-height riser 2 (controlled by CPU1)
■ One x16 PCIe Gen5 riser, standard PCIe, half-height, 3/4 length
Riser 3 Option
UCSC-RIS3A-22XM7 UCS C-Series M7 1U Riser 3A PCIe Gen4 x16 HH (CPU2)
■ Half-height riser 3 (controlled by CPU 2)
■One x16 PCIe Gen4 riser, standard PCIe, supports Cisco VIC, half-height, 3/4 length
UCSC-RIS3C-22XM7 UCS C-Series M7 1U Riser 3C PCIe Gen5 x16 FH (CPU2)
■ Full-height riser 3 (controlled by CPU 2)
■ One x16 PCIe Gen5 riser, standard PCIe, supports Cisco VIC, full-height, 3/4 length
Accessories/spare included along with selected risers:
■ UCSC-FBRS2-C220M7 for riser 2 and UCSC-FBRS-C220-D riser filler blank for riser 3 is auto included, if
riser 2 or riser 3 are not selected. UCSC-FBRSF-220M7 is auto included if only one full height riser is
selected

Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model) 16
CONFIGURING the SERVER

Approved Configurations

(1) Half-height riser 1A, 2A, and 3A only. riser 1A and 2A are controlled from CPU1 and Riser 3
is controlled from CPU2.

(2) Half-height risers 1B, 2B, and 3A only. Risers 1B and 2B are controlled from CPU1 and Riser
3A is controlled from CPU2

(3) Full-height risers 1C and 3C only. Riser 1C is controlled from CPU1 and riser 3C is controlled
from CPU2.

17 Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER

STEP 3 SELECT CPU(s) (REQUIRED)


The standard CPU features are:

■ The 5th Gen. Intel® Xeon® Scalable Processors are paired with Intel® C741 series chipset:
— Up to 60 cores
— Cache size of up to 300 MB
— Power: Up to 300Watts
— UPI Links: Up to 3 at 20GT/s
■ The 4th Gen. Intel® Xeon® Scalable Processors are paired with Intel® C741 series chipset:
— Up to 52 cores
— Cache size of up to 105 MB
— Power: Up to 300Watts
— UPI Links: Up to 3 at 16GT/s

Select CPUs

NOTE: If you try to upgrade an existing C220M7 Server from 4th Gen CPUs to 5th Gen
CPUs, a new air duct (UCSC-AD-C220M7=) may be required. Please refer to the
installation guide for more details.

■ The available 5th Gen. Intel® Xeon® Scalable CPUs are listed in Table 5. See Table 7 on page
21 for CPU suffix notations.
■ The available 4th Gen. Intel® Xeon® Scalable CPUs are listed in Table 6. See Table 7 on page
21 for CPU suffix notations.

CAUTION: Normal operating temperature is limited to 35o C [95o F], and is lowered
to 28o C [82.4o F], with a fan fault.

Table 5 Available 5th Gen. Intel® Xeon® Scalable CPUs

Maximum Clock Cache Highest DDR5 DIMM


Product ID Segment/Workload Socket Cores Freq Power Size Clock Support
(PID) (S) (C) (GHz) (W) (MB) (MT/s)
8000 Series Processors
UCS-CPU-I8581V1 1-S Cloud/SaaS 1S 60 2.00 270 300.00 4800
UCS-CPU-I8571N1 1-S Networking 1S 52 2.40 300 300.00 4800
UCS-CPU-I8562Y+ 2S Performance 2S 32 2.80 300 60.00 5600
UCS-CPU-I8558U1 1-Socket
1S 48 2.00 300 260.00 4800
Optimized

Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model) 18
CONFIGURING the SERVER

Table 5 Available 5th Gen. Intel® Xeon® Scalable CPUs

Maximum Clock Cache Highest DDR5 DIMM


Product ID Segment/Workload Socket Cores Freq Power Size Clock Support
(PID) (S) (C) (GHz) (W) (MB) (MT/s)
6000 Series Processors
UCS-CPU-I6554S Storage 2S 36 2.20 270 180.00 5200
UCS-CPU-I6548Y+ 2S Performance 2S 32 2.50 250 60.00 5200
UCS-CPU-I6548N Networking 2S 32 2.80 250 60.00 5200
UCS-CPU-I6544Y 2S Performance 2S 16 3.60 270 45.00 5200
UCS-CPU-I6542Y 2S Performance 2S 24 2.90 250 60.00 5200
UCS-CPU-I6538Y+ 2S Mainline 2S 32 2.20 225 60.00 5200
UCS-CPU-I6538N Networking 2S 32 2.10 205 60.00 5200
UCS-CPU-I6534 2S Performance 2S 8 3.90 195 22.50 4800
UCS-CPU-I6530 2S Mainline 2S 32 2.10 270 160.00 4800
UCS-CPU-I6526Y 2S Performance 2S 16 2.80 195 37.50 5200
5000 Series Processors
UCS-CPU-I5520+ 2S Mainline 2S 28 2.20 205 52.50 4800
UCS-CPU-I5515+ 2S Performance 2S 8 3.20 165 22.50 4800
UCS-CPU-I5512U1 1-Socket
1S 28 2.10 185 52.50 4800
Optimized
4000 Series Processors
UCS-CPU-I4516Y+ 2S Mainline 2S 24 2.20 185 45.00 4400
UCS-CPU-I4514Y 2S Mainline 2S 16 2.00 150 30.00 4400
UCS-CPU-I4510T2 EDGE (IOT) 2S 12 2.00 115 30.00 4400
UCS-CPU-I45102 2S Mainline 2S 12 2.40 150 30.00 4400
UCS-CPU-I4509Y2 2S Mainline 2S 8 2.60 125 22.50 4400
3000 Series Processors
UCS-CPU-I3508U1,2 1-Socket 1S 8 2.10 125 22.50 4400
Optimized
Accessories/spare included with CPU configuration:
■ UCSC-HSLP-C220M7
NOTE: if you are adding a second CPU later, you may need to order accessories spares with it.
Notes:
1. You cannot have two of these CPUs in a two-CPU configuration and you cannot later upgrade to a 2-CPU system
with two of these CPUs.
2. 48GB and 96GB memory DIMMs not supported on UCS-CPU-I3508U, UCS-CPU-I4509Y, UCS-CPU-I4510,
UCS-CPU-I4510T

19 Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER

Table 6 Available 4th Gen. Intel® Xeon® Scalable CPUs

Maximum Clock Cache Highest DDR5 DIMM


Product ID Segment/Workload Socket Cores Freq Power Size Clock Support
(PID) (S) (C) (GHz) (W) (MB) (MT/s)
8000 Series Processors
UCS-CPU-I8471N1 5G/Networking 1S 52 1.80 300 97.50 4800
UCS-CPU-I8470N 5G/Networking 2S 52 1.70 300 97.50 4800
UCS-CPU-I8462Y+ 2S Performance 2S 32 2.80 300 60.00 4800
UCS-CPU-I8461V1 Cloud/SaaS/Media 1S 48 2.20 300 97.50 4800
UCS-CPU-I8460Y+ 2S Performance 2S 40 2.00 300 105.00 4800
UCS-CPU-I8454H IMDB/Analytics 2S 32 2.10 270 82.50 4800
UCS-CPU-I8452Y 2S Mainline 2S 36 2.00 300 67.50 4800
UCS-CPU-I8450H IMDB/Analytics 2S 28 2.00 250 75.00 4800
UCS-CPU-I8444H IMDB/Analytics 2S 16 2.90 270 45.00 4800
6000 Series Processors
UCS-CPU-I6454S Storage 2S 32 2.20 270 60.00 4800
UCS-CPU-I6448Y 2S Performance 2S 32 2.10 225 60.00 4800
UCS-CPU-I6448H IMDB/Analytics 2S 32 2.40 250 60.00 4800
UCS-CPU-I6444Y 2S Performance 2S 16 3.60 270 45.00 4800
UCS-CPU-I6442Y 2S Performance 2S 24 2.60 225 60.00 4800
UCS-CPU-I6438Y+ 2S Mainline 2S 32 2.00 205 60.00 4800
UCS-CPU-I6438N 5G/Networking 2S 32 2.00 205 60.00 4800
UCS-CPU-I6438M Cloud/SaaS/Media 2S 32 2.20 205 60.00 4800
UCS-CPU-I6434H IMDB/Analytics 2S 8 3.70 195 22.50 4800
UCS-CPU-I6434 2S Performance 2S 8 3.70 195 22.50 4800
UCS-CPU-I6430 2S Mainline 2S 32 2.10 270 60.00 4400
UCS-CPU-I6428N 5G/Networking 2S 32 1.80 185 60.00 4000
UCS-CPU-I6426Y 2S Performance 2S 16 2.50 185 37.50 4800
UCS-CPU-I6421N1 5G/Networking 1S 32 1.80 185 60.00 4400
UCS-CPU-I6418H IMDB/Analytics 2S 24 2.10 185 60.00 4800
UCS-CPU-I6416H IMDB/Analytics 2S 18 2.20 165 45.00 4800
UCS-CPU-I6414U1 1S gen. purpose 1S 32 2.00 250 60.00 4800
5000 Series Processors
UCS-CPU-I5420+ 2S Mainline 2S 28 2.00 205 52.50 4400

Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model) 20
CONFIGURING the SERVER

Table 6 Available 4th Gen. Intel® Xeon® Scalable CPUs

Maximum Clock Cache Highest DDR5 DIMM


Product ID Segment/Workload Socket Cores Freq Power Size Clock Support
(PID) (S) (C) (GHz) (W) (MB) (MT/s)
UCS-CPU-I5418Y 2S Mainline 2S 24 2.00 185 45.00 4400
UCS-CPU-I5418N 5G/Networking 2S 24 1.80 165 45.00 4000
UCS-CPU-I5416S Storage 2S 16 2.00 150 30.00 4400
UCS-CPU-I5415+ 2S Performance 2S 8 2.90 150 22.50 4400
UCS-CPU-I5412U1 1S gen. purpose 1S 24 2.10 185 45.00 4400
UCS-CPU-I5411N1 5G/Networking 1S 24 1.90 165 45.00 4400
4000 Series Processors
UCS-CPU-I4416+ 2S Mainline 2S 20 2.00 165 37.50 4000
UCS-CPU-I4410Y 2S Mainline 2S 12 2.00 150 30.00 4000
UCS-CPU-I4410T IOT 2S 10 2.70 150 26.25 4000
3000 Series Processors
UCS-CPU-I3408U1 1S gen. purpose 1S 8 1.80 125 22.50 4000
Accessories/spare included with CPU configuration:
■ UCSC-HSLP-C220M7
Please note, if you are adding a second CPU later, you may need to order accessories with it.
Notes:
1. You cannot have two of these CPUs in a two-CPU configuration and you cannot later upgrade to a
2-CPU system with two of these CPUs.

Table 7 CPU Suffixes

CPU Suffix Description Features

P Cloud (IaaS) Designed for cloud IaaS environments to deliver higher


frequencies at constrained TDPs

V Cloud (SaaS) Designed for high rack density, maximize VM/core, and lower
power VM environment

M Media Transcode Designed for Media processing, AI, and HPC workloads

H DB and Analytics Designed for Data Analytics and Big Data usages

N Network/5G/Edge Designed and optimized for a range of broadly-deployed


(High TDP/Low network and 5G workload environments from Edge to the Data
latency) Center

S Storage & HCI Designed for Storage usages and workloads

21 Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER

Table 7 CPU Suffixes

CPU Suffix Description Features

T Long-life Use/High Designed for Network Environment-Building System (NEBS) and


Tcase IoT market

U 1-Socket Optimized for targeted platforms adequately served by the


cores, memory bandwidth and IO capacity available from a
single processor

Y General SKU with Designator is used for general SKU stack to highlight SST-PP
SST-PP (Speed Select Technology Performance Profile) feature enabled

+ Feature Plus SKU Designed to enable 1 instance of each DSA, IAA, QAT, DLB
embedded accelerator

Supported Configurations

■ For 1-CPU systems, the server can support up to:


— two half-height risers 1 and 2, or
— one full-height riser 1
■ For 2-CPU systems, the server can support up to:
— three half-height risers 1, 2, and 3, or
— two full-height risers 1 and 2,
■ For the UCSC-C220-M7S:
— 2 CPUs are required if direct-attach NVMe drives are selected
■ For the UCSC-C220-M7N:
— Select one or two identical CPUs
— Up to 4 drives are allowed with 1-CPU configuration and can only be installed in
slots 5, 8, 9, and 10.

The selection of 1 or 2 CPUs depends on the desired server functionality. See the following
sections:

— STEP 4 SELECT MEMORY (REQUIRED), page 23


— STEP 5 SELECT DRIVE CONTROLLERS (OPTIONAL), page 30
— STEP 6 SELECT DRIVES (OPTIONAL), page 34
— STEP 7 SELECT OPTION CARD(s) (OPTIONAL), page 38

Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model) 22
CONFIGURING the SERVER

STEP 4 SELECT MEMORY (REQUIRED)


The Table 8 below describes the main memory DIMM features supported on Cisco UCS C220 M7 Rack server.

Table 8 C220 M7 Main Memory Features

Memory DIMM server technologies Description

4th Gen. CPU: Up to 4800MT/s 1DPC; Up to 4400MT/s 2DPC


DDR5 memory clock speed
5th Gen. CPU: Up to 5600MT/s 1DPC; Up to 4400MT/s 2DPC

Operational voltage 1.1 Volts

DRAM fab density 16Gb and 24Gb

DRAM DIMM type RDIMM (Registered DDR5 DIMM with on die ECC)

Memory DIMM organization Eight memory DIMM channels per CPU; up to 2 DIMMs per channel

Maximum number of DRAM DIMM per 32 (2-Socket)


server

16GB 1Rx8, 32GB 1Rx4, 64GB 2Rx4, 128GB 4Rx4


DRAM DIMM Densities and Ranks
48GB 1Rx4, 96GB 2Rx4 - 5th Gen. only

Maximum system capacity (DRAM


4TB (32x 128GB)
DIMMs only)

23 Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER

Figure 6 Cisco UCS 220 M7 Memory Organization


Slot 1

Slot 2

Slot 2

Slot 1
A1 A2 A2 A1

Chan A Chan A

B1 B2 B2 B1

Chan B
Chan B

C1 C2 C2 C1
Chan C Chan C

D1 D2 D2 D1
Chan D Chan D

CPU 1 CPU 2
E1 E2 E2 E1

Chan E Chan E

F1 F2 F2 F1

Chan F Chan F

G1 G2 G2 G1

Chan G Chan G

H1 H2 H2 H1

Chan H Chan H

8 memory channels per CPU,


up to 2 DIMMs per channel
32 DIMMS total (16 DIMMs per CPU)

Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model) 24
CONFIGURING the SERVER

Select DIMMs and Memory Mirroring

Select the memory configuration and whether or not you want the memory mirroring option. The available
memory DIMMs and mirroring option are listed in Table 9.

NOTE: When memory mirroring is enabled, the memory subsystem simultaneously writes
identical data to two channels. If a memory read from one of the channels returns incorrect data
due to an uncorrectable memory error, the system automatically retrieves the data from the
other channel. A transient or soft error in one channel does not affect the mirrored data, and
operation continues unless there is a simultaneous error in exactly the same location on a DIMM
and its mirrored DIMM. Memory mirroring reduces the amount of memory available to the
operating system by 50% because only one of the two populated channels provides data.

Table 9 Available DDR5 DIMMs

Product ID (PID) PID Description

DDR5-4800MT/s PID list


UCS-MRX16G1RE1 16GB DDR5-4800 RDIMM 1Rx8 (16Gb)
UCS-MRX32G1RE1 32GB DDR5-4800 RDIMM 1Rx4 (16Gb)
UCS-MRX64G2RE1 64GB DDR5-4800 RDIMM 2Rx4 (16Gb)
UCS-MR128G4RE1 128GB DDR5-4800 RDIMM 4Rx4 (16Gb)
DDR5-5600MT/s PID list1
UCS-MRX16G1RE3 16GB DDR5-5600 RDIMM 1Rx8 (16Gb)
UCS-MRX32G1RE3 32GB DDR5-5600 RDIMM 1Rx4 (16Gb)
UCS-MRX48G1RF32,3 48GB DDR5-5600 RDIMM 1Rx4 (24Gb)
UCS-MRX64G2RE3 64GB DDR5-5600 RDIMM 2Rx4 (16Gb)
UCS-MRX96G2RF33 96GB DDR5-5600 RDIMM 2Rx4 (24Gb)
UCS-MR128G4RE3 128GB DDR5-5600 RDIMM 4Rx4 (16Gb)
Memory Mirroring Option
N01-MMIRRORD Memory mirroring option
Accessories/spare included with Memory configuration:
■ UCS-DDR5-BLK4 is auto included for the unselected DIMMs slots

Notes:
1. DDR5-5600 supported on Intel Xeon 5th gen. CPUs only.
2. Available post first customer ship (FCS).
3. 48Gb and 96GB memory DIMMs not supported on UCS-CPU-I3508U, UCS-CPU-I4509Y, UCS-CPU-I4510,
UCS-CPU-I4510T
4. Any empty DIMM slot must be populated with a DIMM blank to maintain proper cooling airflow.

25 Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER

Memory configurations and mixing rules


■ Golden Rule: Memory on every CPU socket shall be configured identically.
■ System speed is dependent on the CPU DIMM speed support. Refer to Available 4th Gen. Intel® Xeon®
Scalable CPUs, page 20 and Available 5th Gen. Intel® Xeon® Scalable CPUs, page 18 for DIMM
speeds.
■ For full details on supported memory configurations see the M7 Memory Guide.
■ DIMM Count Rules:

Table 10 Allowed DIMM Count for 1-CPU and 2-CPU

Allowed DIMM Minimum Maximum Allowed Count Not Allowed Count


Count rules Count Count

16GB, 32GB, 64GB, 128GB,(4th and 5th Gen. CPUs)

DIMM count for 1 CPU 1 16 1,2,4,6,8,12,16 3,5,7,9,10,11,13,14,15

DIMM count for 2-CPU 2 32 2,4,8,12,16,24,32 6,10,14,18,20,22,26,28,30

48GB (5th Gen. CPUs Only)

2,3,4,5,7,9,10,11,12,13,14,15,
DIMM count for 1 CPU 1 8 1,6,8
16

4,6,8,10,14,18,20,22,24,26,28,
DIMM count for 2-CPU 2 16 2,12,16
30,32

96GB (5th Gen. CPUs Only)

DIMM count for 1 CPU 1 16 1,6,8,12,16 2,3,4,5,7,9, 10,11,13,14,15

DIMM count for 2-CPU 2 32 2,12,16,24,32 4,6,8,10,14,18,20,22,26,28,30

NOTE(1): 12 DIMMs count for 1-CPU, 24 DIMMs count and for 2-CPU configurations are only allowed when all
DIMMs have the same density.

Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model) 26
CONFIGURING the SERVER

■ DIMM Population Rules:


■ Each channel has two memory slots (for example, channel A = slots A1 and A2). See golden
rule above.
— A channel can operate with one or two DIMMs installed.
— If a channel has only one DIMM, populate slot 1 first (the blue slot).
■ When both CPUs are installed, populate the memory slots of each CPU identically. Fill the
blue slots (slot 1) in the memory channels first according to the recommended DIMM
populations in Table 11.0, Table 11.1 and Table 11.2.

Table 11.0 M7 DIMM population order for 16GB, 32GB, 64GB, and128GB

DIMM Population - 16GB, 32GB, 64GB, 128GB(4th and 5th Gen. CPUs)1
#DIMMs per CPU
Slot 1 (Blue) Slot 2 (Black)
1 A1 -
2 A1, G1 -
4 A1, C1, E1, G1 -
6 A1, C1, D1, E1, F1, G1 -
8 A1, B1, C1, D1, E1, F1, G1, H1 -
122 A1, B1, C1, D1, E1, F1, G1, H1 A2, C2, E2, G2
16 A1, B1, C1, D1, E1, F1, G1, H1 A2, B2, C2, D2, E2, F2, G2, H2

Notes:
1. See DIMM Mixing Rules for allowed combinations across slots 1 and 2.
2. Only valid when DIMMs in blue and black slots are the same density.

Table 11.1 M7 DIMM population order for 48GB

DIMM Population - 48GB (5th Gen. CPUs only)1,2


#DIMMs per CPU
Slot 1 (Blue) Slot 2 (Black)
1 A1 -
6 A1, C1, D1, E1, F1, G1 -
8 A1, B1, C1, D1, E1, F1, G1, H1 -

Notes:
1. 48GB DIMMs cannot be mixed with other DIMM capacities.
2. Only 1 DPC supported by 48GB.

Table 11.2 M7 DIMM population order for 96GB

DIMM Population - 96GB (5th Gen. CPUs only)1


#DIMMs per CPU
Slot 1 (Blue) Slot 2 (Black)
1 A1 -
6 A1, C1, D1, E1, F1, G1 -
8 A1, B1, C1, D1, E1, F1, G1, H1 -
122 A1, B1, C1, D1, E1, F1, G1, H1 A2, C2, E2, G2
162 A1, B1, C1, D1, E1, F1, G1, H1 A2, B2, C2, D2, E2, F2, G2, H2

27 Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER

Notes:
1. 96GB DIMMs cannot be mixed with other DIMM capacities.
2. Only valid when DIMMs in blue and black slots are the same density.
■ DIMM Mixing Rules:
■ Higher rank DIMMs shall be populated on Slot 1.
■ Mixing different DIMM densities in the same slot across channels is not supported. All
populated slots of the same color must have the same DIMM density.
■ Mixing X4 and X8 DIMMs is not allowed
■ Mixing 16Gb DRAM based and 24Gb DRAM based DIMMs is not allowed. Therefore, 48GB and
96GB cannot be mixed with any other memory DIMMs
■ 48GB supports 1 DIMM Per Channel (1DPC) only
■ The DIMM mixing rules matrix is described in the Table 12 and Table 13, below

Table 12 Supported DIMM mixing and population across 2 slots in each channel - 16GB, 32GB, 64GB, and
128GB

Channel Mixing DIMM Slot 2 (Black)

16GB 32GB 64GB 128GB


DIMM Slot 1 (Blue)
1Rx8 1Rx4 2Rx4 4Rx4

16GB 1Rx8 Yes1 No No No

32GB 1Rx4 No Yes1 No No

64GB 2Rx4 No Yes2 Yes1 No

128GB 4Rx4 No No No Yes1

Notes:
1. For 2,4,6, 8 DIMMs count, only populate slot 1 (Blue slot). see Table 11.0 for details
2. When mixing two different DIMM densities, all 8 channels per CPU must be populated. Use of fewer than 8
channels (16 slots per CPU) is not supported.

Table 13 Supported DIMM mixing and population across 2 slots in each channel - 48GB and 96GB DIMMs

Channel Mixing DIMM Slot 2 (Black)

48GB 96GB
DIMM Slot 1 (Blue)
1Rx4 2Rx4

48GB 1Rx4 No No

96GB 2Rx4 No Yes1

Notes:
1. For 6, 8 DIMMs count, only populate slot 1 (Blue slot). see Table 11.2 for details

Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model) 28
CONFIGURING the SERVER

■ Memory Limitations:
■ Memory on every CPU socket shall be configured identically.
■ Refer to Table 11.0, Table 11.1 and Table 11.2. and Table 12 and Table 13, for DIMM
population and DIMM mixing rules.
■ Cisco memory from previous generation servers (DDR3 and DDR4) is not supported with the
M7 servers.
■ For best performance, observe the following:
■ For optimum performance, populate at least one DIMM per memory channel per CPU. When
one DIMM per channel is used, it must be populated in DIMM slot 1 (blue slot farthest away
from the CPU) of a given channel.
■ The maximum 2 DPC speed is 4400 MT/s, refer to Table 14.0 and Table 14.1 for the details.

Table 14.0 DDR5-4800 DIMM 1DPC and 2DPC max speed matrix - 4th Gen. CPU

1DPC 2DPC
4th Gen. CPU Shelves
and Memory Speed
All RDIMMs All RDIMMs

Platinum Series 8 4800 MT/s 4400 MT/s

Gold Series 6 4800 MT/s 4400 MT/s

Gold Series 5 4400 MT/s 4400 MT/s

Silver Series 4 4000 MT/s 4000 MT/s

Bronze Series 3 4000 MT/s 4000 MT/s

Table 14.1 DDR5-5600 DIMM 1DPC and 2DPC max speed matrix - 5th Gen. CPU

1DPC 2DPC
5th Gen. CPU Shelves and Memory
Speed
All RDIMMs All RDIMMs

Platinum Series 8 5600 MT/s 4400 MT/s

Gold Series 6 5200 MT/s 4400 MT/s

Gold Series 5 4800 MT/s 4400 MT/s

Silver Series 4 4400 MT/s 4400 MT/s

Bronze Series 3 4400 MT/s 4400 MT/s

NOTE: For full details on supported memory configurations see the M7 Memory Guide.

29 Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER

STEP 5 SELECT DRIVE CONTROLLERS (OPTIONAL)


The following list summarizes how drives are controlled on the server:

■ Servers with SATA drives (only) are controlled by an Intel C621 PCH through the SATA
Interposer (AHCI)
■ Up to 10 SAS/SATA/NVMe drives are controlled through a Cisco 24G Tri-mode RAID controller
■ Up to 10 SAS/SATA drives are controlled through a Cisco 12G SAS RAID controller.
■ Up to 10 SAS/SATA drives are controlled through a Cisco 12G SAS pass-through HBA.

NOTE: PCIe drives are controlled directly from the CPUs.

RAID Volumes and Groups


When creating each RAID volume, follow these guidelines:

■ Use the same capacity for each drive in each RAID volume
■ For the Cisco 12G SAS RAID controller, use either all SAS HDDs, or all SAS SSDs, or all SATA SSDs in each
RAID volume
■ For the Cisco 24G Tri-mode RAID controller, use either all SAS HDDs, or all SAS SSDs, or all SATA SSDs or
NVMe SSDs in each RAID volume.

NOTE: 240 virtual drives (VDs) per controller, with up to 64 per disk group with the 12G Raid
Controller, and 16 per disk group with the 24G Tri Mode Controller.

Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model) 30
CONFIGURING the SERVER

RAID Controller Options

If you do not want the default AHCI 8 SATA-only drive setup (8 internal drives in drive bays 1-8
and 2 SATA M.2 drives), select one of the following from Table 15.

■ One Cisco 24G Tri-mode RAID controller or


■ One Cisco 12G RAID controller or
■ One Cisco 12G SAS HBA

NOTE:
■ If the Cisco 24G Tri-mode RAID controller, 12G SAS RAID controller or Cisco 12G SAS HBA is
selected, it is factory-installed in a dedicated slot.
■ All RAID controllers are only supported on UCSC-C220-M7S For UCSC-C220-M7N, drives are
controlled directly from the CPU.
■ The default solution is AHCI, which supports a limited number of drives, operating systems,
and virtualized environments. For a more comprehensive solution, choose a controller from
Table 15.
■ vSAN HCL listed/qualified component is UCSC-SAS-T-D

Table 15 Hardware Controller Options

Product ID (PID) PID Description


Controllers for Internal Drives
UCSC-RAID-HP1,2 Cisco Tri-Mode 24G SAS RAID Controller w/4GB Cache
■ This RAID controller supports up to 10 SAS HDDs and SAS/SATA/NVMe SSDs
operating at 3Gbps, 6Gbps, 12Gbps and 24Gbps. It includes a SuperCap and a
4GB flash-back write cache (FBWC).
■ Supports RAID0, RAID00, 1, 5, 6, 10, 50, 60, and JBOD mode and supports mixed
RAID and JBOD mode.
■ The RAID controller plugs directly into a dedicated slot.
■ For all self-encrypting drives (SED), standalone Management (CIMC/UCSM) is
supported for configuring and managing local keys. For now, SED drives are
managed with local key management only. Third-party key management will be
supported (KMIP compliant).
UCSC-RAID-T-D Cisco M6 12G SAS RAID Controller with 4GB FBWC (16 Drives)
■ This RAID controller supports up to 10 SAS HDDs and SAS/SATA SSD operating at
3Gbps, 6Gbps, and 12Gbps. It includes a SuperCap and a 4GB flash-back write
cache (FBWC).
■ Supports RAID0, RAID00, 1, 5, 6, 10, 50, 60, and JBOD mode and supports mixed
RAID and JBOD mode.
■ The RAID controller plugs directly into a dedicated slot.
■ For all self-encrypting drives (SED), standalone Management (CIMC/UCSM) is
supported for configuring and managing local keys. For now, SED drives are
managed with local key management only. Third-party key management will be
supported (KMIP compliant).

31 Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER

Table 15 Hardware Controller Options (continued)

Product ID (PID) PID Description


UCSC-SAS-T-D Cisco M6 12G SAS HBA for (16 Drives)
■ This SAS HBA supports up to 10 SAS HDDs and SAS/SATA SSDs operating at
3Gbps, 6Gbps, and 12Gbps.
■ No RAID support
■ Supports JBOD or pass-through mode
■ The 12G SAS HBA plugs directly into a dedicated slot.
Controller for External Drives
UCSC-9500-8E-D Cisco 12G 9500-8e 12G SAS HBA for external JBOD attach
■ External Storage HBA plugs in to PCIe slot
■ This controller is half-height half-length and can be installed in riser 1, 2, or 3.
SATA Interposer
UCSC-SATAIN-220M7 UCS C220 M7 SATA Interposer Board (for control of up to 8 SATA-only drives using
AHCI)
■ The default configuration is Advanced Host Control Interface (AHCI), which
supports SATA-only drives. A maximum of 8 SATA drives are supported with AHCI
and this configuration requires a SATA interposer board, which plugs directly
into the drive backplane. The SATA Interposer supports drives in slots 1-8.
■ AHCI is limited to Windows and Linux operating systems only. There is no
VMware support for AHCI.
Accessories/spare included with drive controller (For UCSC-C220-M7S):
■ UCSC-RDBKT-22XM7 is included with the selection of UCSC-SAS-T-D drive controller.
■ CBL-SAS-C220M7, CBL-SCAP-C220-D, UCS-SCAP-D and UCSC-RDBKT-22XM7 are included with the
selection of UCSC-RAID-T-D drive controller
■ CBL-SAS-Y-C220M7, CBL-SCAP-C220-D, UCS-SCAP-D and UCSC-HPBKT-22XM7 are included with the
selection of UCSC-RAID-HP drive controller.
NOTE: If you are adding drive controller later as spare, you may need to order cables/supercap/super cables and
controllers bracket with it.

Notes:
1. When ordering UCSC-RAID-HP, please note that mixing SAS/SATA and NVMe drives in a single RAID volume is not
supported. Virtual drives can only be created with drives of the same type
2. U.3 NVMe drives selected with the Tri-mode RAID controller (UCSC-RAID-HP) will be set to RAID attached as the
factory default. The U.3 drives in slots 1-4 can however operate in U.2 mode, directly attached to the CPU. This
mode can be changed from the Cisco IMC if desired.

Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model) 32
CONFIGURING the SERVER

Select one of the RAID Configuration option from the following Table 16.

CAUTION: All RAID options require drives of same sector size and media type. The smallest
drive capacity will be used to calculate the RAID volume size.

Table 16 RAID Configuration Options

Product ID (PID) PID Description


NOTE: Not available for Cisco 12G SAS HBA
R2XX-SRAID0D Enable single disk RAID 0 Setting.
Factory preconfigured RAID striping option
R2XX-RAID0D
Enable RAID 0 Setting. Requires two or more drive.
Factory preconfigured RAID striping option
R2XX-RAID00D
Enable RAID 00 Setting. Requires two or more drive.
Factory preconfigured RAID mirroring option
R2XX-RAID1D
Enable RAID 1 Setting. Requires even number of drives (minimum of two).
Factory preconfigured RAID option
R2XX-RAID5D
Enable RAID 5 Setting. Requires a minimum of three drives
Factory preconfigured RAID option
R2XX-RAID6D
Enable RAID 6 Setting. Requires a minimum of four drives.
Factory preconfigured RAID option
R2XX-RAID10D
Enable RAID 10 Setting. Requires even number of drives (minimum of 2 drives per span)
Factory preconfigured RAID option
R2XX-RAID50D
Enable RAID 50 Setting. Requires minimum of three drives per span
Factory preconfigured RAID option
R2XX-RAID60D
Enable RAID 60 Setting. Requires minimum of four drives per span.

Approved Configurations

Cisco UCS C220 M7 SFF server can be ordered as follows:

■ UCSC-C220 M7S (10-drive SAS/SATA/NVMe backplane and optionally 4 of those can be


direct-attach NVMe)
■ UCSC-C220-M7N (10-drive direct-attach NVMe only)
■ There is no RAID support for direct-attach NVMe drives.

33 Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER

STEP 6 SELECT DRIVES (OPTIONAL)


The standard disk drive features are:

■ 2.5-inch small form factor


■ Hot-pluggable
■ Drives come mounted in sleds

Select Drives

■ The available NVMe SSDs drives for UCSC-C220-M7N and UCSC-C220-M7S are listed in
Table 17
■ The available SAS/SATA SSDs and HDDs drives for UCSC-C220-M7S listed Table 18

CAUTION: Cisco uses solid state drives (SSDs) from a number of vendors. All solid state
drives (SSDs) are subject to physical write limits and have varying maximum usage limitation
specifications set by the manufacturer. Cisco will not replace any solid state drives (SSDs) that
have exceeded any maximum usage specifications set by Cisco or the manufacturer, as
determined solely by Cisco.

Table 17 Available NVMe drives for UCSC-C220-M7N and UCSC-C220-M7S

Drive Form
Product ID (PID) PID Description Capacity
Type Factor
PCIe/NVMe SFF (2.5-inch) SFF drives
UCS-NVMEXP-I400-D 400GB 2.5in U.2 Intel P5800X Optane NVMe Extreme NVMe U.2 400 GB
Perform SSD
UCS-NVMEXP-I800-D 800GB 2.5in U.2 Intel P5800X Optane NVMe Extreme NVMe U.2 800 GB
Perform SSD
UCS-NVME4-1600-D 1.6TB 2.5in U.2 P5620 NVMe High Perf High NVMe U.2 1.6 TB
Endurance
UCS-NVME4-1920-D 1.9TB 2.5in U.2 P5520 NVMe High Perf Medium NVMe U.2 1.9 TB
Endurance
UCS-NVME4-3200-D 3.2TB 2.5in U.2 P5620 NVMe High Perf High NVMe U.2 3.2 TB
Endurance
UCS-NVME4-3840-D 3.8TB 2.5in U.2 P5520 NVMe High Perf Medium NVMe U.2 3.8 TB
Endurance
UCS-NVME4-6400-D 6.4TB 2.5in U.2 P5620 NVMe High Perf High NVMe U.2 6.4 TB
Endurance
UCS-NVME4-7680-D 7.6TB 2.5in U.2 P5520 NVMe High Perf Medium NVMe U.2 7.6 TB
Endurance
UCS-NVME4-15360-D 15.3TB 2.5in U.2 P5520 NVMe High Perf Medium NVMe U.2 15.3 TB
Endurance
UCS-NVMEQ-1536-D 15.3TB 2.5in U.2 P5316 NVMe High Perf Low NVMe U.2 15.3 TB
Endurance
UCS-NVMEG4-M960-D 1 960GB 2.5in U.3 Micron P7450 NVMe High Perf NVMe U.3 960 GB
Medium Endurance
UCS-NVMEG4-M1920D 1 1.9TB 2.5in U.3 Micron P7450 NVMe High Perf Medium NVMe U.3 1.9 TB
Endurance

Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model) 34
CONFIGURING the SERVER

Table 17 Available NVMe drives (continued)for UCSC-C220-M7N and UCSC-C220-M7S

Drive Form
Product ID (PID) PID Description Capacity
Type Factor
UCS-NVMEG4-M3840D1 3.8TB 2.5in U.3 Micron P7450 NVMe High Perf Medium NVMe U.3 3.8 TB
Endurance
UCS-NVMEG4-M7680D1 7.6TB 2.5in U.3 Micron P7450 NVMe High Perf Medium NVMe U.3 7.6 TB
Endurance
UCS-NVMEG4-M1536D1 15.3TB 2.5in U.3 MicronP7450 NVMe High Perf NVMe U.3 15.3 TB
Medium Endurance
UCS-NVMEG4-M1600D1 1.6TB 2.5in U.3 Micron P7450 NVMe High Perf High NVMe U.3 1.6 TB
Endurance
UCS-NVMEG4-M3200D1 3.2TB 2.5in U.3 Micron P7450 NVMe High Perf High NVMe U.3 3.2 TB
Endurance
UCS-NVMEG4-M6400D1 6.4TB 2.5in U.3 Micron P7450 NVMe High Perf High NVMe U.3 6.4 TB
Endurance
■ CBL-FNVME-C220M7 is auto included with selection of U.3 NVMe drives and Raid controller
UCSC-RAID-HP.
Notes:
1. Only U.3 drives are allowed with RAID 24G Tri-mode RAID Controller and NVMe Hardware RAID.

Table 18 Available SAS/SATA SSD and HDDs for UCSC-C220-M7S

Drive
Product ID (PID) PID Description Capacity
Type
HDDs
HDDs (10K RPM)
UCS-HD600G10KJ4-D 600 GB 12G SAS 10K RPM SFF HDD SAS 600 GB
UCS-HD12TB10KJ4-D 1.2 TB 12G SAS 10K RPM SFF HDD SAS 1.2 TB
UCS-HD18TB10KJ4-D 1.8 TB 12G SAS 10K RPM SFF HDD (4K) SAS 1.8 TB
UCS-HD24TB10KJ4-D 2.4 TB 12G SAS 10K RPM SFF HDD (4K) SAS 2.4 TB
Enterprise Performance SAS/SATA SSDs (High endurance, supports up to 10X or 3X DWPD (drive writes
per day))
SATA
UCS-SD480G63XEP-D 480 GB 2.5in Enterprise Performance 6G SATA SSD(3X endurance) SATA 480 GB
UCS-SD960G63XEP-D 960 GB 2.5in Enterprise performance 6G SATA SSD(3X endurance) SATA 960 GB
UCS-SD19T63X-EP-D 1.9 TB 2.5in Enterprise performance 6G SATA SSD(3X endurance) SATA 1.9 TB
UCS-SD38T63X-EP-D 3.8 TB 2.5in Enterprise performance 6G SATA SSD(3X endurance) SATA 3.8 TB
UCS-SD480GBM3XEPD 480GB SATA SSD 3DWPD SATA 480 GB
UCS-SD960GBM3XEPD 960GB SATA SSD 3DWPD SATA 960 GB
UCS-SD19TBM3XEP-D 1.9TB SATA SSD 3DWPD SATA 1.9 TB
SAS
UCS-SD800GK3XEP-D 800 GB 2.5in Enterprise Performance 12G SAS SSD(3X endurance) SAS 800 GB
UCS-SD16TK3X-EP-D 1.6 TB 2.5in Enterprise Performance 12G SAS SSD(3X endurance) SAS 1.6 TB
UCS-SD32TK3X-EP-D 3.2 TB 2.5in Enterprise Performance 12G SAS SSD(3X endurance) SAS 3.2 TB
UCS-SD16TKA3XEP-D 1.6TB 2.5in Enterprise Performance 12G SAS SSD(3X endurance) SAS 1.6 TB
UCS-SD32TKA3XEP-D 3.2TB 2.5in Enterprise Performance 12G SAS SSD(3X endurance) SAS 3.2 TB

35 Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER

Table 18 Available SAS/SATA SSD and HDDs (continued)for UCSC-C220-M7S

Drive
Product ID (PID) PID Description Capacity
Type
UCS-SD64TS3XEP-D 6.4TB 2.5in Enterprise Performance 12G SAS SSD(3X endurance) SAS 6.4 TB
Enterprise Value SAS/SATA SSDs (Low endurance, supports up to 1X DWPD (drive writes per day))
SATA
UCSSD480G6I1XEV-D 480GB 2.5 inch Enterprise Value 6G SATA SSD SATA 480 GB
UCSSD960G6S1XEV-D 960GB 2.5 inch Enterprise Value 6G SATA SSD SATA 960 GB
UCSSD960G6I1XEV-D 960GB 2.5 inch Enterprise Value 6G SATA SSD SATA 960 GB
UCS-SD19T6S1XEV-D 1.9TB 2.5 inch Enterprise Value 6G SATA SSD SATA 1.9 TB
UCS-SD38T6S1XEV-D 3.8 TB 2.5 inch Enterprise Value 6G SATA SSD SATA 3.8 TB
UCS-SD38T6I1XEV-D 3.8TB 2.5 inch Enterprise Value 6G SATA SSD SATA 3.8 TB
UCS-SD76T6S1XEV-D 7.6TB 2.5 inch Enterprise Value 6G SATA SSD SATA 7.6 TB
UCS-SD76TM1X-EV-D 7.6TB 2.5 inch Enterprise Value 6G SATA SSD SATA 7.6 TB
UCS-SD240GBM1XEVD 240GB SATA SSD 1DWPD SATA 240 GB
UCS-SD480GBM1XEVD 480GB SATA SSD 1DWPD SATA 480 GB
UCS-SD960GBM1XEVD 960GB SATA SSD 1DWPD SATA 960 GB
UCS-SD16TBM1XEV-D 1.6GB SATA SSD 1DWPD SATA 1.6 TB
UCS-SD19TBM1XEV-D 1.9TB SATA SSD 1DWPD SATA 1.9 TB
UCS-SD38TBM1XEV-D 3.8TB SATA SSD 1DWPD SATA 3.8 TB
UCS-SD76TBM1XEV-D 7.6TB SATA SSD 1DWPD SATA 7.6 TB
UCS-SDB960SA1VD 960GB 2.5in 6G SATA Enter Value 1X Samsung G1PM893A SSD SATA 960 GB
UCS-SDB1T9SA1VD 1.9TB 2.5in 6G SATA Enter Value 1X Samsung G1PM893A SSD SATA 1.9 TB
UCS-SDB3T8SA1VD 3.8TB 2.5in 6G SATA Enter Value 1X Samsung G1PM893A SSD SATA 3.8 TB
UCS-SDB7T6SA1VD 7.6TB 2.5in 6G SATA Enter Value 1X Samsung G1PM893A SSD SATA 7.6 TB
SAS
UCS-SD960GK1XEV-D 960GB 2.5 inch Enterprise Value 12G SAS SSD SAS 960 GB
UCS-SD19TK1X-EV-D 1.9TB 2.5 inch Enterprise Value 12G SAS SSD SAS 1.9 TB
UCS-SD38TK1X-EV-D 3.8TB 2.5 inch Enterprise Value 12G SAS SSD SAS 3.8 TB
UCS-SD76TK1X-EV-D 7.6TB 2.5 inch Enterprise Value 12G SAS SSD SAS 7.6 TB
UCS-SD15TK1X-EV-D 15.3TB 2.5 inch Enterprise Value 12G SAS SSD SAS 15.3 TB
UCS-SD19TKA1XEV-D 1.9TB 2.5 inch Enterprise Value 12G SAS SSD SAS 1.9 TB
UCS-SD38TKA1XEV-D 3.8TB 2.5 inch Enterprise Value 12G SAS SSD SAS 3.8 TB
UCS-SD76TKA1XEV-D 7.6TB 2.5 inch Enterprise Value 12G SAS SSD SAS 7.6 TB
UCS-SD76TS1X-EV-D 7.6TB 2.5 inch Enterprise Value 12G SAS SSD SAS 7.6 TB
UCS-SD15TKA1XEV-D 15.3TB 2.5 inch Enterprise Value 12G SAS SSD SAS 15.3 TB
Self-Encrypted Drives (SED) (1X or 3X)
SATA
UCSSD38TBEM2NK9-D 3.8TB Enterprise value SATA SSD (1X, SED) Non FIPS SATA 3.8 TB
SAS
UCS-SD800GBKNK9-D 800GB Enterprise Performance SAS SSD (3X DWPD, SED) FIPS140-2 SAS 800 GB

Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model) 36
CONFIGURING the SERVER

Table 18 Available SAS/SATA SSD and HDDs (continued)for UCSC-C220-M7S

Drive
Product ID (PID) PID Description Capacity
Type
UCS-SD960GBKNK9-D 960GB Enterprise Value SAS SSD (1X DWPD, SED) FIPS140-2 SAS 960 GB
UCS-SD16TBKNK9-D 1.6TB Enterprise performance SAS SSD (3X DWPD, SED) FIPS140-2 SAS 1.6 TB
UCS-SD38TBKNK9-D 3.8TB Enterprise Value SAS SSD (1X DWPD, SED) FIPS140-2 SAS 3.8 TB
UCS-SD76TBKNK9-D 7.6TB Enterprise value SAS SSD (1X DWPD, SED-FIPS) FIPS140-2 SAS 7.6 TB
UCS-SD16TBKANK9-D 1.6TB 2.5" Enterprise performance 12GSAS SSD(3DWPD,SED-FIPS) SAS 1.6 TB
FIPS140-2
UCS-SD38TBKANK9-D 3.8TB 2.5" Enterprise value 12G SAS SSD (1DWPD, SED-FIPS) SAS 3.8 TB
FIPS140-2
UCS-SD76TBKANK9-D 7.6TB Enterprise value SAS SSD (1DWPD, SED-FIPS) SAS 7.6 TB
FIPS140-2
UCS-SD960GM2NK9-D 960GB SED SSD 1DWPD SAS 960 GB
UCS-SD19TEM2NK9-D 1.9TB SED SSD 1DWPD SAS 1.9 TB
UCS-SD38TEM2NK9-D 3.8TB SED SSD 1DWPD SAS 3.8 TB
UCS-SD76TEM2NK9-D 7.6TB SED SSD 1DWPD SAS 7.6 TB
Accessories/spare included with drives (For UCSC-C220-M7S):
■ CBL-FNVME-C220M7 is auto included with selection of U.3 NVMe drives and Raid controller UCSC-RAID-HP
■ CBL-SATA-C220-D is included with the selection of the SATA drives.
■ UCSC-BBLKD-M7 is included for the not selected front storage device.
NOTE: If you are adding drive later as spare, you may need to order cables with it.

Caveats

■ With the UCSC-C220-M7S:


— You can choose only SATA HDDs when using AHCI with a SATA Interposer. The drives
must be installed in slots 1-8.
— Unless RAID 24G Tri-mode RAID Controller and NVMe Hardware RAID are selected,
SFF NVMe drives are connected directly to CPU2 and not managed by any drive
controller.
— If you order any direct-attach NVMe SFF drives, you must also order two CPUs.
— You can mix HDDs and SSDs as long as you keep all HDDs in their own RAID volume
and all SSDs in their own RAID volume.
— SED drives can be mixed with the non-SED drives in Table 18 on page 35.
■ SFF NVMe drives are bootable in UEFI mode only.

37 Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER

STEP 7 SELECT OPTION CARD(s) (OPTIONAL)


For up-to-date server compatibility, please check the Hardware and Software compatibility list
(HCL) at https://ucshcltool.cloudapps.cisco.com/public/.

The standard PCIe card offerings are:

■ Modular LAN on Motherboard (mLOM)


■ Open Compute Project (OCP) 3.0
■ Virtual Interface Cards (VICs)
■ Network Interface Cards (NICs)
■ Host Bus Adapters (HBAs)

Select Option Cards

The available option cards are listed in Table 19

Table 19 Available PCIe Option Cards

Product ID (PID) PID Description Location Card Size1


Modular LAN on Motherboard (mLOM)
UCSC-M-V5Q50G-D Cisco VIC 15428 4x 10/25/50G mLOM C-Series mLOM HHHL, SS
UCSC-M-V5D200G-D Cisco VIC 15238 2x 40/100/200G mLOM C-Series mLOM HHHL, SS
UCSC-M-V5Q50GV2-D Cisco VIC 15427 4x 10/25/50G mLOM C-Series w/Secure mLOM HHHL, SS
Boot5
UCSC-M-V5D200GV2D Cisco VIC 15237 2x 40/100/200G mLOM C-Series mLOM HHHL, SS
w/Secure Boot5
Open Compute Project (OCP)
UCSC-O-ID10GC-D2 Intel X710T2LOCPV3G1L 2x10GbE RJ45 OCP 3.0 NIC OCP SFF
Virtual Interface Cards (VICs)
UCSC-P-V5Q50G-D Cisco VIC 15425 4x 10/25/50G PCIe C-Series w/Secure Riser 1 or 3 HHHL, SS
Boot5
UCSC-P-V5D200G-D Cisco VIC 15235 2x 40/100/200G PCIe C-Series Riser 1 or 3 HHHL, SS
w/Secure Boot5
Network Interface Cards (NICs)
1GbE NICs
UCSC-P-IQ1GC Cisco-Intel I710-T4L 4x1GBASE-T NIC Riser 1, 2, or 3 HHHL, SS
10GbE NICs
UCSC-PCIEID10GF-D Intel X710-DA2 Dual Port 10Gb SFP+ NIC Riser 1, 2, or 3 HHHL, SS
UCSC-PCIEIQ10GF-D Intel X710 quad-port 10G SFP+ NIC Riser 1, 2, or 3 HHHL, SS
UCSC-P-ID10GC-D Cisco-Intel X710T2LG 2x10GBE RJ45 PCIe NIC Riser 1, 2, or 3 HHHL, SS
UCSC-P-IQ10GC-D Cisco-Intel X710T4LG 4x10GBE RJ45 PCIe NIC Riser 1, 2, or 3 HHHL, SS
25GbE NICs
UCSC-P-I8D25GF-D3 Cisco-Intel E810XXVDA2 2x25/10GBE SFP28 PCIe NIC Riser 1, 2, or 3 HHHL, SS

Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model) 38
CONFIGURING the SERVER

Table 19 Available PCIe Option Cards (continued)

Product ID (PID) PID Description Location Card Size1


UCSC-P-I8Q25GF-D3 Cisco-Intel E810XXVDA4L 4x25/10GBE SFP28 PCIe NIC Riser 1C or 3C FHHL, SS
UCSC-P-N6D25GF-D3 Cisco-NVDA MCX631102AS-ADAT CX6Lx 2x25GbE SFP28 x8 Riser 1, 2, or 3 HHHL, SS
PCIe NIC
UCSC-P-N7Q25GF MCX713104AS-ADAT: CX-7 4x25GbE SFP56 PCIe Gen4x16, Riser 1, 2, or 3 HHHL, SS
VPI NIC
100GbE NICs
UCSC-P-MCD100GF-D3,4 Cisco-MLNX MCX623106AC-CDAT 2x100GbE QSFP56 PCIe Riser 1, 2, or 3 HHHL, SS
NIC (with Crypto)
UCSC-P-MDD100GF-D 3,4 Cisco-MLNX MCX623106AS-CDAT 2x100GbE QSFP56 PCIe Riser 1, 2, or 3 HHHL, SS
NIC
UCSC-P-I8D100GF-D 3,4 Cisco-Intel E810CQDA2 2x100 GbE QSFP28 PCIe NIC Riser 1, 2, or 3 HHHL, SS
200GbE NICs
UCSC-P-N7D200GF MCX755106AS-HEAT:CX-7 2x200GbE QSFP112 PCIe Riser 1, 2, or 3 FHHL, SS
Gen5x16, VPI NIC (Gen5 Riser only)
Host Bus Adapters (HBAs)
UCSC-P-Q6D32GF-D Cisco-QLogic QLE2772 2x32GFC Gen 6 Enhanced PCIe Riser 1, 2, or 3 HHHL, SS
HBA
UCSC-P-B7D32GF-D Cisco-Emulex LPe35002-M2-2x32GFC Gen 7 PCIe HBA Riser 1, 2, or 3 HHHL, SS
UCSC-PCIEQD16GF-D Qlogic QLE2692 dual-port 16G FC HBA Riser 1, 2, or 3 HHHL, SS
UCSC-PCIEBD16GF-D Emulex LPe31002 dual port 16G FC HBA Riser 1, 2, or 3 HHHL, SS
UCSC-P-Q7D64GF Cisco-QLogic QLE2872, 2x64GFC Gen 7 PCIe HBA Riser 1, 2, or 3 HHHL, SS
External Storage HBA
UCSC-9500-8E-D Cisco 12G 9500-8e 12G SAS HBA for external JBOD Riser 1, 2, or 3 HHHL, SS
attach
Accessories/spare included with PCI Card.
■ UCSC-OCP3-KIT-D is included along with the selection UCSC-O-ID10GC-D card5

Notes:
1. HHHL = half-height, half-length; FHHL = full-height, half-length; SS = single-slot; DS = double-slot. SFF
= small form factor.
2. For installation in the mLOM slot, you can order either an mLOM VIC, or the OCP NIC - but not both. If
ordering the OCP NIC, the OCP Mechanical Kit (UCSC-OCP3-KIT) must also be installed in order to
mount OCP NIC in the mLOM slot.
3. When present, the recommended Fan Speed Control policy setting is balanced.
4. NICs with 16 active electrical lanes, such as the 100G NICs, can be inserted in slots with 8 active
electrical lanes.The NIC will function but may exhibit degraded performance.
5. This Virtual Interface Cards incorporate VIC Secure Boot technology

Approved Configurations

(1) 1-CPU Systems

■ You can select up to two of the PCIe option cards listed in Table 19 to be installed in Riser 1
and Riser 2. Riser 1 and Riser 2 is controlled by CPU 1. Risers 3 cannot installed in a 1-CPU
system.

39 Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER

(2) 2-CPU Systems

■ You can select up to two of the PCIe option cards listed in Table 19 for a two-riser system
and up to three of the PCIe option cards for a three-riser system. Risers 1 and 2 are
controlled by CPU and riser 3 is controlled by CPU 2.

Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model) 40
CONFIGURING the SERVER

Caveats

■ For 1-CPU systems:


— Half Height Riser 1 and Riser 2 is supported. Full Height Riser 1 is supported
— Only a single plug-in PCIe VIC card is supported and must be installed in Riser 1.
However, in addition to the one PCIe VIC card, you can also choose to install an
mLOM/OCP 3.0 card in the mLOM slot at the rear of the chassis.
■ For 2-CPU systems:
— All risers (Risers 1, 2, and 3) are supported
— Two plug-in PCIe VIC cards can be installed in 2-CPU systems. VICs can be placed in
Riser 1 or 3 only for 1U in half height riser combination. For full height riser, you can
use either Riser 1 or 2 for the VICs. In addition, you can order an mLOM/OCP 3.0
card, which is installed in the mLOM/OCP 3.0 slot at the rear of the chassis and thus
have three VIC cards in operation at the same time. See Table 19 on page 38 for
the selection of plug-in and mLOM VIC cards. See also Figure 7 on page 60 for the
mLOM VIC card slot.
■ To help ensure that your operating system is compatible with the card you have selected, or
to see additional cards that have been qualified to work with the UCS C220 M7 server, but
are not sold on the Cisco pricelist, check the Hardware Compatibility List at this URL:
http://www.cisco.com/en/US/products/ps10477/prod_technical_reference_list.html

■ For installation in the mLOM slot, you can order either an mLOM VIC, or the OCP NIC - but
not both. If ordering the OCP NIC, the OCP Mechanical Kit (UCSC-OCP3-KIT) must also be
installed in order to mount OCP NIC in the mLOM slot.

ORDER OPTIONAL PCIe OPTION CARD ACCESSORIES


■ At the time of first launch, the 3rd Party Ethernet adapters were tested for interoperability with an initial
selection of Optical Modules and Cables. Please check the Product Briefs for this initial list of
interoperable optics and cables at
https://www.cisco.com/c/en/us/products/servers-unified-computing/third-party-adapters-listing.html.
■ For list of supported optics and cables for VIC 15428 and VIC 15238, refer to the VIC 15000 series data
sheet at
https://www.cisco.com/c/en/us/products/collateral/interfaces-modules/unified-computing-system-ad
apters/ucs-vic-15000-series-ds.htm
■ Cisco Transceiver Module Group (TMG) conducts tests with Cisco optics and cables and publishes the
results in the TMG Compatibility Matrix. The latest compatibility with optical modules and DACs can be
found at https://tmgmatrix.cisco.com/
■ Refer to the these links for additional connectivity options.

Intel:
Product Guide
Speed White Paper

41 Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER

STEP 8 ORDER GPU CARDS (OPTIONAL)

CAUTION:
■ Gen4 and Gen5 risers cannot be mixed, for example: If UCSC-RIS2A-C22XM7
(GEN4) is selected, cannot select UCSC-RIS2B-C22XM7 (GEN5)

Select GPU Options

The available GPU PCIe options are listed in Table 20.

Table 20 Available PCIe GPU Cards1

Maximum
Product ID (PID) PID Description Card Size cards Per Riser Compatibility
node

NVIDIA L4:70W,
HHHL, Gen 4 & Gen 5 Half Height and
UCSC-GPU-L4 24GB, 1-slot 3 Full Hight Riser
single-wide
HHHL GPU

Intel GPU Flex


HHHL, Gen 5 and Gen 4 Half Height
UCSC-GPU-FLEX140 140, Gen4x8, 3 Risers
single-wide
HHHL, 75W PCIe

Notes:
1. Refer to installation guide for the more details.

NOTE:
■ All GPU cards must be procured from Cisco as there is a unique SBIOS ID
required by CIMC and UCSM
■ GPUs cannot be mixed.

Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model) 42
CONFIGURING the SERVER

STEP 9 ORDER POWER SUPPLY (REQUIRED)


Power supplies share a common electrical and physical design that allows for hot-plug and tool-less
installation into M7 C-series servers. Each power supply is certified for high-efficiency operation and offers
multiple power output options. This allows users to “right-size” based on server configuration, which
improves power efficiency, lowers overall energy costs and avoids stranded capacity in the data center.

Use the power calculator at the following link to determine the needed power based on the options chosen
(CPUs, drives, memory, and so on):

http://ucspowercalc.cisco.com

WARNING:
■ Starting 1st January 2024, only Titanium rated PSUs are allowed to be shipped to
European Union (EU), European Economic Area (EEA), United Kingdom (UK),
Switzerland and other countries that adopted Lot 9 Regulation.
■ DC PSUs are not impacted by Lot 9 Regulation and are EU/UK Lot 9 compliant

Table 21 Power Supply

Product ID (PID) PID Description


PSU (Input High Line 210VAC)
UCSC-PSU1-770W-D UCS C-series 770W AC PSU (Not EU/UK Lot 9 Compliant)
UCSC-PSUV21050D-D Cisco UCS 1050W -48V DC Power Supply for Rack Server Platinum
UCSC-PSUV21050DCI1 1050W -48V DC power supply for C-Series servers (India)
UCSC-PSU1-1200W-D 1200W Titanium power supply for C-Series Servers Titanium
UCSC-PSU1-1600W-D UCS 1600W AC PSU Platinum (Not EU/UK Lot 9 Compliant)
UCSC-PSU1-2300W-D 2300W Power supply for C-series servers Titanium
PSU (Input Low Line 110VAC)
UCSC-PSU1-770W-D UCS C-series 770W AC PSU (Not EU/UK Lot 9 Compliant)
UCSC-PSU1-1200W-D 1200W Titanium power supply for C-Series Servers Titanium
UCSC-PSU1-2300W-D 2300W Power supply for C-series servers Titanium
Notes:
1. This power supply supported with NO-POWER-CORD and CAB-48DC-40A-8AWG

NOTE:
■ In a server with two power supplies, both power supplies must be identical.
■ Refer to Power Specifications, page 81 section for the full details on the each power
supply.

43 Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER

STEP 10 SELECT INPUT POWER CORD(s) (REQUIRED)


Using Table 22 and Table 23, select the appropriate AC power cords. You can select a minimum of no
power cords and a maximum of two. If you select the option R2XX-DMYMPWRCORD, no power cord is
shipped with the server.

NOTE: Table 22 lists the power cords for servers that use power supplies less than 2300 W.
Table 23 lists the power cords for servers that use 2300 W power supplies. Note that the power
cords for 2300 W power supplies use a C19 connector so they only fit the 2300 W power supply
connector.

Table 22 Available Power Cords (for server PSUs less than 2300 W)

Product ID (PID) PID Description Images


NO-POWER-CORD ECO friendly green option, no
power cable will be shipped
CAB-48DC40A8AWG-D C-Series -48VDC PSU Power Cord,
3.5M, 3 Wire, 8AWG, 40A

CAB-N5K6A-NA Power Cord, 200/240V 6A, North


America
Cordset rating: 10 A, 250 V
Plug: NEMA 6-15P Length: 8.2 ft

Connector:
IEC60320/C13

186570
CAB-AC-L620-C13-D AC Power Cord, NEMA L6-20 - C13,
2M/6.5ft

CAB-C13-CBN CABASY,WIRE,JUMPER CORD, 27" L,


C13/C14, 10A/250V

CAB-C13-C14-2M CABASY,WIRE,JUMPER CORD, PWR,


2 Meter, C13/C14,10A/250V

Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model) 44
CONFIGURING the SERVER

Table 22 Available Power Cords (for server PSUs less than 2300 W)

Product ID (PID) PID Description Images


CAB-C13-C14-AC CORD,PWR,JMP,IEC60320/C14,IEC6
0320/C13, 3.0M

CAB-250V-10A-AR Power Cord, 250V, 10A, Argentina


2500 mm

Cordset rating: 10 A, 250/500 V MAX


Length: 8.2 ft
Plug:
EL 219
(IRAM 2073) Connector:
EL 701
(IEC60320/C13)

186571
CAB-9K10A-AU Power Cord, 250VAC 10A 3112 Plug,
Australia
Cordset rating: 10 A, 250 V/500 V MAX
Length: 2500mm

Connector:
Plug: EL 701C
EL 210 (EN 60320/C15)

186580
(BS 1363A) 13 AMP fuse

CAB-250V-10A-CN AC Power Cord - 250V, 10A - PRC

CAB-9K10A-EU Power Cord, 250VAC 10A CEE 7/7


Plug, EU
Cordset rating: 10A/16 A, 250 V
Plug: Length: 8 ft 2 in. (2.5 m)
M2511
Connector:
VSCC15

186576
CAB-250V-10A-ID Power Cord, 250V, 10A, India
OVE

Cordset rating 16A, 250V


Plug:
(2500mm)
EL 208

Connector:
EL 701
187490

CAB-C13-C14-3M-IN Power Cord Jumper, C13-C14 Image not available


Connectors, 3 Meter Length, India
CAB-C13-C14-IN Power Cord Jumper,C13-C14 Image not available
Connectors,1.4 Meter Length, India
CAB-250V-10A-IS Power Cord, SFS, 250V, 10A, Israel
EL-212
16A
250V

Cordset rating 10A, 250V/500V MAX


(2500 mm)

Connector:
Plug: EL 701B
EL 212 (IEC60320/C13)
186574

(SI-32)

45 Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER

Table 22 Available Power Cords (for server PSUs less than 2300 W)

Product ID (PID) PID Description Images


CAB-9K10A-IT Power Cord, 250VAC 10A CEI
23-16/VII Plug, Italy
Cordset rating: 10 A, 250 V
Plug: Length: 8 ft 2 in. (2.5 m) Connector
I/3G C15M
(CEI 23-16) (EN60320/C15 )

186575
CAB-9K10A-SW Power Cord, 250VAC 10A MP232
Plug, Switzerland
Cordset rating: 10 A, 250 V
Plug: Length: 8 ft. 2 in (2.5 m)
MP232-R
Connector:
IEC 60320 C15

186578
CAB-9K10A-UK Power Cord, 250VAC 10A BS1363
Plug (13 A fuse), UK
Cordset rating: 10 A, 250 V/500 V MAX
Length: 2500mm

Connector:
Plug: EL 701C
EL 210 (EN 60320/C15)

186580
(BS 1363A) 13 AMP fuse

CAB-9K12A-NA1 Power Cord, 125VAC 13A NEMA


5-15 Plug, North America

CAB-250V-10A-BR Power Cord - 250V, 10A - Brazil


1 76.2 From Plug End

2,133.6 ± 25

CAB-C13C142M-JP-D Power Cord C13-C14, 2M/6.5ft Image not available


Japan PSE mark
CAB-9K10A-KOR1 Power Cord, 125VAC 13A KSC8305 Image not available
Plug, Korea
CAB-ACTW AC Power Cord (Taiwan), C13, EL Image not available
302, 2.3M
CAB-JPN-3PIN Japan, 90-125VAC 12A NEMA 5-15 Image not available
Plug, 2.4m
CAB-48DC40A-INT-D C-Series -48VDC PSU PWR Cord, Image not available
3.5M, 3 Wire, 8AWG, 40A (INT)
CAB-48DC-40A-AS-D C-Series -48VDC PSU PWR Cord, Image not available
3.5M, 3Wire, 8AWG, 40A (AS/NZ)
Notes:
1. This power cord is rated to 125V and only supported for PSU rated at 1050W or less

Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model) 46
CONFIGURING the SERVER

Table 23 Available Power Cords (for servers with 2300 W PSUs)

Product ID (PID) PID Description Images

CAB-C19-CBN Cabinet Jumper Power Cord, 250 VAC 16A, Not applicable
C20-C19 Connectors

CAB-S132-C19-ISRL S132 to IEC-C19 14ft Israeli Image not available

CAB-IR2073-C19-AR IRSM 2073 to IEC-C19 14ft Argen Image not available

CAB-BS1363-C19-UK BS-1363 to IEC-C19 14ft UK Image not available

CAB-SABS-C19-IND SABS 164-1 to IEC-C19 India Image not available

CAB-C2316-C19-IT CEI 23-16 to IEC-C19 14ft Italy Image not available

CAB-US515P-C19-US NEMA 5-15 to IEC-C19 13ft US Image not available

CAB-US520-C19-US NEMA 5-20 to IEC-C19 14ft US Image not available

CAB-US620P-C19-US NEMA 6-20 to IEC-C19 13ft US Image not available

CAB-9K16A-BRZ Power Cord 250VAC 16A, Brazil, Src Plug Image not available
EL224-C19

CAB-9K16A-KOR Power Cord 250VAC 16A, Korea, Src Plug Image not available

CAB-AC-16A-AUS Power Cord, 250VAC, 16A, Australia C19 Image not available

CAB-AC-2500W-EU Power Cord, 250Vac 16A, Europe Image not available

CAB-AC-2500W-INT Power Cord, 250Vac 16A, INTL Image not available

CAB-AC-2500W-ISRL Power Cord,250VAC,16A,Israel Image not available

CAB-AC-C19-TW Power Cord, 250 V, 16A, C19, Taiwan Image not available

CAB-AC-C6K-TWLK Power Cord, 250Vac 16A, twist lock NEMA Image not available
L6-20 plug, US

CAB-AC16A-CH 16A AC Power Cord For China Image not available

CAB-ACS-16 AC Power Cord (Swiss) 16A Image not available

CAB-C19-C20-3M-JP Power Cord C19-C20, 3M/10ft Japan PSE mark Image not available

CAB-C19-C20-IND Power Cord C19-C20 India Image not available

UCSB-CABL-C19-BRZ NBR 14136 to C19 AC 14FT POWER CORD, Image not available
BRAZIL

NO-POWER-CORD ECO friendly green option, no power cable Image not available
will be shipped

47 Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER

STEP 11 ORDER TOOL-LESS RAIL KIT (REQUIRED) AND REVERSIBLE


CABLE MANAGEMENT ARM (OPTIONAL)
■ Tool-less Rail Kit:

Select a tool-less rail kit (or no rail kit) from Table 24.

NOTE:
■ Cisco recommends a minimum quantity of 1 Rail Kit
■ If you plan to rackmount your UCS C220 M7 server, you must order a tool-less rail kit.

Table 24 Tool-less Rail Kit Options

Product ID (PID) PID Description

UCSC-RAIL-D Ball Bearing Rail Kit for C220 & C240 M6/M7 rack servers

UCSC-RAIL-NONE-D No rail kit option

■ Optional Reversible Cable Management Arm:

The reversible cable management arm mounts on either the right or left slide rails at the rear of the server
and is used for cable management. Select an Optional Reversible Cable Management Arm from Table 25.

NOTE: If you plan to rackmount your UCS C220 M7 server, you must order a tool-less rail kit. The
same rail kits and CMAs are used for M6 and M7 servers.

Table 25 Cable Management Arm

Product ID (PID) PID Description

UCSC-CMA-C220-D Reversible CMA for C220 M6/M7 ball bearing rail kit

For more information about the tool-less rail kit and cable management arm, check the Cisco
UCS C220 M7 Installation Guide.

Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model) 48
CONFIGURING the SERVER

STEP 12 SELECT MANAGEMENT CONFIGURATION (OPTIONAL)


By default, the C220 M7 server NIC mode is configured to be Shared LOM Extended. This NIC
mode allows any LOM port or adapter card port to be used to access the Cisco Integrated
Management Controller (CIMC). The Cisco VIC card must be installed in a slot with NCSI support.

NOTE:
■ There are no LOM ports on the C220 and C240 M7 servers. Servers ordered
without a VIC or OCP card will ship in Dedicated network mode, unless otherwise
specified by a configurable SW PID (UCSC-CCARD-01)
■ For full details on all the NIC mode settings, see
https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/c/hw/C220M7/in
stall/b-c220-m7-installation-guide.html

Table 26 Management Configuration Ordering Information

Product ID (PID) PID Description

UCSC-DLOM-01-D Dedicated Mode BIOS setting for C-Series Servers


■ To change the default NIC mode to Dedicated NIC mode, select this card.
■ In Dedicated NIC mode, the CIMC can be accessed only through the
dedicated management port.
■ See Chassis Rear View (two full-height, 3/4-length PCIe risers), page 8
for the location of the management port

UCSC-CCARD-01-D Cisco Card Mode BIOS setting for C-Series Servers


■ To change the default NIC mode to Cisco Card Mode, select this card.
■ If Cisco card selected, a VIC or MLOM must also be included in the
configuration. if OCP card is included in the configuration, a VIC card must
be selected.
■ In this mode, you can assign an IP address to the CIMC using DHCP and from
there you can fully automate your deployment.

In addition, the optional software PIDs listed in Table 34 on page 53 can be ordered for setting
the server to operate in various modes.

49 Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER

STEP 13 ORDER SECURITY DEVICES (REQUIRED)


A Trusted Platform Module (TPM) is a computer chip (microcontroller) that can securely store
artifacts used to authenticate the platform (server). These artifacts can include passwords,
certificates, or encryption keys. A TPM can also be used to store platform measurements that
help ensure that the platform remains trustworthy. Authentication (ensuring that the platform
can prove that it is what it claims to be) and attestation (a process helping to prove that a
platform is trustworthy and has not been breached) are necessary steps to ensure safer
computing in all environments.

A chassis intrusion switch gives a notification of any unauthorized mechanical access into the
server.

The security device ordering information is listed in Table 27

NOTE:
■ The TPM module used in this system conforms to TPM v1.2 and 2.0, as defined
by the Trusted Computing Group (TCG). It is also SPI-based.
■ TPM installation is supported after-factory. However, a TPM installs with a
one-way screw and cannot be replaced, upgraded, or moved to another server. If
a server with a TPM is returned, the replacement server must be ordered with a
new TPM.

Table 27 Security Devices

Product ID (PID) PID Description

UCSX-TPM-002C-D Trusted Platform Module 2.0 for UCS servers

UCSC-INT-SW02-D C220 and C240 M7 Chassis Intrusion Switch

UCSX-TPM-OPT-OUT-D OPT OUT, TPM 2.0, TCG, FIPS140-2, CC EAL4+ Certified1

Notes:
1. Please note that Microsoft certification requires a TPM 2.0 for bare-metal or guest VM deployments. Opt-out
of the TPM 2.0 voids the Microsoft certification

Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model) 50
CONFIGURING the SERVER

STEP 14 SELECT LOCKING SECURITY BEZEL (OPTIONAL)


An optional locking bezel can be mounted to the front of the chassis to prevent unauthorized
access to the drives.

Select the locking bezel from Table 28.

Table 28 Locking Bezel Option

Product ID (PID) Description


UCSC-BZL-C220-D C220 M7 Security Bezel

51 Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER

STEP 15 ORDER M.2 SATA SSDs (OPTIONAL)


■ Order one or two matching M.2 SATA SSDs from Table 29 along with a boot-optimized RAID controller
(see Table 30). See Figure 7 on page 60 for the location of the modu le connector on the motherboard.
This connector accepts the boot-optimized RAID controller. Each boot-optimized RAID controller can
accommodate up to two SATA M.2 SSDs.

NOTE:
■ It is recommended that M.2 SATA SSDs be used as boot-only devices.
■ Order one or two identical M.2 SATA SSDs for the boot optimized RAID controller
■ You cannot mix M.2 SATA SSD capacities.

Table 29 M.2 SATA SSDs

Product ID (PID) PID Description


UCS-M2-I240GB-D 240GB SATA M.2 SSD
UCS-M2-I480GB-D 480GB SATA M.2 SSD
UCS-M2-240G-D 240GB M.2 SATA Micron G2 SSD
UCS-M2-480G-D 480GB M.2 SATA SSD
UCS-M2-960G-D 960GB M.2 SATA Micron G2 SSD

■ Order Cisco boot optimized M.2 RAID controller from Table 30. The boot optimized RAID controller
plugs into a connector on the motherboard and holds up to two M.2 SATA drives.

NOTE:
■ The Cisco boot optimized M.2 RAID controller supports VMWare, Windows and Linux
Operating Systems
■ The Cisco boot optimized M.2 RAID controller supports RAID 1 and JBOD mode
■ The Cisco boot optimized M.2 RAID controller is available only with 240GB, 480GB, and
960GB M.2 SSDs.
■ CIMC is supported for configuring of volumes and monitoring of the controller and installed
SATA M.2 drives
■ The SATA M.2 drives can boot in UEFI mode only. Legacy boot mode is not supported
■ Hot-plug replacement is not supported. The server must be powered off.

Table 30 Boot-Optimized RAID Controller

Product ID (PID) PID Description

UCS-M2-HWRAID-D Cisco Boot optimized M.2 RAID controller (holds up to two M.2 SATA SSDs)

Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model) 52
CONFIGURING the SERVER

STEP 16 ORDER M.2 NVMe AND RAID CONTROLLER(OPTIONAL)


■ Order one or two matching M.2 NVMe from Table 31 along with a boot-optimized RAID controller (see
Table 32). See Figure 7 on page 60 for the location of the module connector on the motherboard. This
connector accepts the boot-optimized RAID controller. Each boot-optimized RAID controller can
accommodate up to two SATA M.2 NVMe

NOTE:
■ It is recommended that M.2 NVMe be used as boot-only devices.
■ Order one or two identical M.2 NVMe for the boot optimized RAID controller
■ You cannot mix M.2 NVMe capacities.

Table 31 M.2 NVMe

Product ID (PID) PID Description


UCS-NVM2-400GB 400GB M.2 Boot NVMe
UCS-NVM2-960GB 960GB M.2 Boot NVMe

■ Order Cisco boot optimized M.2 NVMe RAID controller from Table 32. The boot optimized RAID
controller plugs into a connector on the motherboard and holds up to two M.2 NVMe drives.

Table 32 Boot-Optimized RAID Controller

Product ID (PID) PID Description

UCS-M2-NVRAID Cisco M.2 NVMe BOOT RAID Controller (HHHL)

Table 33 Riser supported Matrix for M.2 NVMe Boot Raid Controller

Risers- Gen Risers Slot UCS-M2-NVRAID - Slot

3HH Gen4 Risers 1A, 2A, 3A 2A

2HH Gen5 Risers


1B, 2B, 3B 2B
1HH Gen4 Risers

2FH Gen4 Risers 1C, 3C 1C

53 Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER

STEP 17 SELECT OPERATING SYSTEM AND VALUE-ADDED SOFTWARE


Select

■ Cisco Software (Table 34)


■ Operating System (Table 35)

NOTE:
■ See this link for operating system guidance:
https://ucshcltool.cloudapps.cisco.com/public/
■ VMware is on Compliance Hold. Contact the
[email protected] mailer to see if you are allowed to receive
VMware Licenses

Table 34 OEM Software

Product ID (PID) PID Description

VMware vCenter

VMW-VCS-STD-D1A VMware vCenter 7 Server Standard, 1 yr support required

VMW-VCS-STD-D3A VMware vCenter 7 Server Standard, 3 yr support required

VMW-VCS-STD-D5A VMware vCenter 7 Server Standard, 5 yr support required

VMW-VCS-FND-D1A VMware vCenter Server 7 Foundation (4 Host), 1 yr supp reqd

VMW-VCS-FND-D3A VMware vCenter Server 7 Foundation (4 Host), 3 yr supp reqd

VMW-VCS-FND-D5A VMware vCenter Server 7 Foundation (4 Host), 5 yr supp reqd

Table 35 Operating System

Product ID (PID) PID Description

Microsoft Windows Server

MSWS-22-ST16CD Windows Server 2022 Standard (16 Cores/2 VMs)

MSWS-22-ST16CD-NS Windows Server 2022 Standard (16 Cores/2 VMs) - No Cisco SVC

MSWS-22-DC16CD Windows Server 2022 Data Center (16 Cores/Unlimited VMs)

MSWS-22-DC16CD-NS Windows Server 2022 DC (16 Cores/Unlim VMs) - No Cisco SVC

MSWS-19-ST16CD Windows Server 2019 Standard (16 Cores/2 VMs)

MSWS-19-ST16CD-NS Windows Server 2019 Standard (16 Cores/2 VMs) - No Cisco SVC

MSWS-19-DC16CD Windows Server 2019 Data Center (16 Cores/Unlimited VMs)

Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model) 54
CONFIGURING the SERVER

Table 35 Operating System (continued)

Product ID (PID) PID Description

MSWS-19-DC16CD-NS Windows Server 2019 DC (16 Cores/Unlim VMs) - No Cisco SVC

Red Hat

RHEL-2S2V-D1A Red Hat Enterprise Linux (1-2 CPU,1-2 VN); 1-Yr Support Req

RHEL-2S2V-D3A Red Hat Enterprise Linux (1-2 CPU,1-2 VN); 3-Yr Support Req

RHEL-2S2V-D5A Red Hat Enterprise Linux (1-2 CPU,1-2 VN); 5-Yr Support Req

RHEL-VDC-2SUV-D1A RHEL for Virt Datacenters (1-2 CPU, Unlim VN) 1 Yr Supp Req

RHEL-VDC-2SUV-D3A RHEL for Virt Datacenters (1-2 CPU, Unlim VN) 3 Yr Supp Req

RHEL-VDC-2SUV-D5A RHEL for Virt Datacenters (1-2 CPU, Unlim VN) 5 Yr Supp Req

Red Hat Ent Linux/ High Avail/ Res Strg/ Scal

RHEL-2S2V-D1S Red Hat Enterprise Linux (1-2 CPU,1-2 VN); Prem 1Yr SnS Reqd

RHEL-2S2V-D3S Red Hat Enterprise Linux (1-2 CPU,1-2 VN); Prem 3Yr SnS Reqd

RHEL-2S-HA-D1S RHEL High Availability (1-2 CPU); Premium 1-yr SnS Reqd

RHEL-2S-HA-D3S RHEL High Availability (1-2 CPU); Premium 3-yr SnS Reqd

RHEL-2S-RS-D1S RHEL Resilent Storage (1-2 CPU); Premium 1-yr SnS Reqd

RHEL-2S-RS-D3S RHEL Resilent Storage (1-2 CPU); Premium 3-yr SnS Reqd

RHEL-VDC-2SUV-D1S RHEL for Virt Datacenters (1-2 CPU, Unlim VN) 1 Yr SnS Reqd

RHEL-VDC-2SUV-D3S RHEL for Virt Datacenters (1-2 CPU, Unlim VN) 3 Yr SnS Reqd

Red Hat SAP

RHEL-SAP-2S2V-D1S RHEL for SAP Apps (1-2 CPU, 1-2 VN); Prem 1-Yr SnS Reqd

RHEL-SAP-2S2V-D3S RHEL for SAP Apps (1-2 CPU, 1-2 VN); Prem 3-Yr SnS Reqd

RHEL-SAPSP-D3S RHEL SAP Solutions Premium - 3 Years

RHEL-SAPSS-D3S RHEL SAP Solutions Standard - 3 Years

VMware

VMW-VSP-STD-D1A VMware vSphere 7 Std (1 CPU, 32 Core) 1-yr, Support Required

VMW-VSP-STD-D3A VMware vSphere 7 Std (1 CPU, 32 Core) 3-yr, Support Required

VMW-VSP-STD-D5A VMware vSphere 7 Std (1 CPU, 32 Core) 5-yr, Support Required

VMW-VSP-EPL-D1A VMware vSphere 7 Ent Plus (1 CPU, 32 Core) 1Yr, Support Reqd

VMW-VSP-EPL-D3A VMware vSphere 7 Ent Plus (1 CPU, 32 Core) 3Yr, Support Reqd

VMW-VSP-EPL-D5A VMware vSphere 7 Ent Plus (1 CPU, 32 Core) 5Yr, Support Reqd

55 Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER

Table 35 Operating System (continued)

Product ID (PID) PID Description

SUSE

SLES-2S2V-D1A SUSE Linux Enterprise Svr (1-2 CPU,1-2 VM); 1-Yr Support Req

SLES-2S2V-D3A SUSE Linux Enterprise Svr (1-2 CPU,1-2 VM); 3-Yr Support Req

SLES-2S2V-D5A SUSE Linux Enterprise Svr (1-2 CPU,1-2 VM); 5-Yr Support Req

SLES-2SUVM-D1A SUSE Linux Enterprise Svr (1-2 CPU,Unl VM) LP; 1Y Supp Req

SLES-2SUVM-D3A SUSE Linux Enterprise Svr (1-2 CPU,Unl VM) LP; 3Y Supp Req

SLES-2SUVM-D5A SUSE Linux Enterprise Svr (1-2 CPU,Unl VM) LP; 5Y Supp Req

SLES-2S-LP-D1A SUSE Linux Live Patching Add-on (1-2 CPU); 1yr Support Req

SLES-2S-LP-D3A SUSE Linux Live Patching Add-on (1-2 CPU); 3yr Support Req

SLES-2S2V-D1S SUSE Linux Enterprise Svr (1-2 CPU,1-2 VM); Prio 1-Yr SnS

SLES-2S2V-D3S SUSE Linux Enterprise Svr (1-2 CPU,1-2 VM); Prio 3-Yr SnS

SLES-2S2V-D5S SUSE Linux Enterprise Svr (1-2 CPU,1-2 VM); Prio 5-Yr SnS

SLES-2SUVM-D1S SUSE Linux Enterprise Svr (1-2 CPU,Unl VM) LP; Prio 1Y SnS

SLES-2SUVM-D3S SUSE Linux Enterprise Svr (1-2 CPU,Unl VM) LP; Prio 3Y SnS

SLES-2SUVM-D5S SUSE Linux Enterprise Svr (1-2 CPU,Unl VM) LP; Prio 5Y SnS

SLES-2S-HA-D1S SUSE Linux High Availability Ext (1-2 CPU); 1yr SnS

SLES-2S-HA-D3S SUSE Linux High Availability Ext (1-2 CPU); 3yr SnS

SLES-2S-HA-D5S SUSE Linux High Availability Ext (1-2 CPU); 5yr SnS

SLES-2S-GC-D1S SUSE Linux GEO Clustering for HA (1-2 CPU); 1yr Sns

SLES-2S-GC-D3S SUSE Linux GEO Clustering for HA (1-2 CPU); 3yr SnS

SLES-2S-GC-D5S SUSE Linux GEO Clustering for HA (1-2 CPU); 5yr SnS

SLES-2S-LP-D1S SUSE Linux Live Patching Add-on (1-2 CPU); 1yr SnS Required

SLES-2S-LP-D3S SUSE Linux Live Patching Add-on (1-2 CPU); 3yr SnS Required

SLES and SAP

SLES-SAP-2S2V-D1S SLES for SAP Apps (1-2 CPU, 1-2 VM); Priority 1-Yr SnS

SLES-SAP-2S2V-D3S SLES for SAP Apps (1-2 CPU, 1-2 VM); Priority 3-Yr SnS

SLES-SAP-2S2V-D5S SLES for SAP Apps (1-2 CPU, 1-2 VM); Priority 5-Yr SnS

SLES-SAP-2S2V-D1A SLES for SAP Apps w/ HA (1-2 CPU, 1-2 VM); 1-Yr Support Reqd

SLES-SAP-2S2V-D3A SLES for SAP Apps w/ HA (1-2 CPU, 1-2 VM); 3-Yr Support Reqd

Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model) 56
CONFIGURING the SERVER

Table 35 Operating System (continued)

Product ID (PID) PID Description

SLES-SAP-2S2V-D5A SLES for SAP Apps w/ HA (1-2 CPU, 1-2 VM); 5-Yr Support Reqd

57 Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER

STEP 18 CHOOSE OPTIONAL OPERATING SYSTEM MEDIA KIT

Select the optional operating00 system media listed in Table 36.

Table 36 OS Media

Product ID (PID) PID Description

MSWS-19-ST16CD-RM Windows Server 2019 Stan (16 Cores/2 VMs) Rec Media DVD Only

MSWS-19-DC16CD-RM Windows Server 2019 DC (16Cores/Unlim VM) Rec Media DVD Only

MSWS-22-ST16CD-RM Windows Server 2022 Stan (16 Cores/2 VMs) Rec Media DVD Only

MSWS-22-DC16CD-RM Windows Server 2022 DC (16Cores/Unlim VM) Rec Media DVD Only

Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model) 58
SUPPLEMENTAL MATERIAL

SUPPLEMENTAL MATERIAL
Block Diagrams
NOTE: Only one drive configuration option is possible at a time UCSC-C220-M7S SFF Block Diagram Rear Panel
UCSC-C220-M7S USB 3.0 x 1 USB 3.0/2.0
OPTION 1 USB 3.0 x 1
USB 3.0/2.0
Front drives 1-4 & 6-9
all SATA RGB VGA
1 COM
SATA Serial
2 Interposer
3 Drive
Intel
4
Backplane X8 MiniSAS X8 Slimline SATA 3.0 x8 EMMITSBURG USB 2.0 x1
6 Connector connector PCH
7 PCIe 2.0 x 1
8 eSPI RGMII 1 GB-T
9 DMI3 RGMII/MDI (Mgmt)
BMC
PCIe 3.0 x4 SATA 3.0 x4
Mini Storage

(types vary with mLOM/OCP 3.0 module)


Module USB 2.0 x 1
DMI3 (x4)
(two M.2 SSDs)

. . . . . . . . . . . .
OPTION 2 DDR5 DIMMs

Network connectors
A1 A2
Front drives 1-10
SAS/SATA only Chan A
DMI3
1
2 B1 B2 mLOM/OCP
3 12G RAID
4 Drive Controller CPU1
Chan B Module
SAS/SATA PCIe 4.0 x 16
5 Backplane or 12G SAS PCIe 4.0 x 8 C1 C2
6 HBA Chan C PCIe 4.0 x 16
7
8 CPU1
D1 D2 PCIe 5.0 x 16
9
Chan D
10
4th Gen Intel® Xeon®
E1 E2 Scalable Processor
Chan E (Sapphire Rapids) Front Panel
KVM
Connector
F1 F2
OPTION 3
Front drives CPU2 PCIe 4.0 x 16 (for 4 NVMe drives) Chan F
1-4 SAS/SATA or NVMe
5-10 SAS/SATA only USB 2.0 x 2
G1 G2
1 VGA
1 NVMe Chan G
. 1 Serial COM
2 .
3 . H1 H2
NVMe 12G RAID CPU1
4 PCIe 4.0 x 8 Chan H
SAS/SATA
Drive Controller or (for SAS/SATA drives)
5 Backplane 12G SAS
6 .
.
HBA
7 UPI (3x 16 GT/s)
. DDR5 DIMMs PCIe Riser 1A (1 HH slot)
8
A1 A2
9 SAS/SATA Slot 1
PCIe 4.0 x 16
10 Chan A

B1 B2
PCIe Riser 2A (1 HH slot)

Chan B PCIe 4.0 x 16 Slot 1


3 HH Gen 4 Riser Configuration
OPTION 4 C1 C2
(note: With option 4, a tri mode controller is used. Drives 1-10 can be SAS/SATA/ PCIe Riser 3A (1 HH slot)
Chan C
NVMe, with the option for drives 1-4 as direct attach to the CPU (similar to option 3).
CPU2 PCIe 4.0 x 16 (drive 1-4) CPU2 PCIe 4.0 x 16 Slot 1
D1 D2

Chan D
4th Gen Intel® Xeon® PCIe 5.0 x 16
1 SAS/ PCIe Riser 1B (1 HH slot)
SATA/ E1 E2 Scalable Processor
2
NVMe Chan E (Sapphire Rapids) PCIe 5.0 x 16 Slot 1
3
4 CPU1
PCIe 4.0 x 16 F1 F2 2 HH Gen 5 Riser Configuration
Drive 24G RAID PCIe Riser 2B (1 HH slot)
(for SAS/SATA/NVMe drives) Chan F
5 Backplane Controller Slot 1
SAS/ PCIe 5.0 x 16
6 SATA/ G1 G2
7 NVMe
8 Chan G
9
H1 H2
10
Chan H PCIe 5.0 x 16 PCIe Riser 1C (1 FH slot)

Slot 1

PCIe Riser 3C (1 FH slot) 2 FH Riser Configuration


PCIe 5.0 x 16
Slot 1

59 Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model)
SUPPLEMENTAL MATERIAL

NOTE: Only one drive configuration option is possible at a time UCSC-C220-M7N SFF Block Diagram Rear Panel
USB 3.0 x 1 USB 3.0/2.0
USB 3.0 x 1
USB 3.0/2.0
RGB VGA
UCSC-C220-M7N
COM
Serial
Intel
EMMITSBURG USB 2.0 x1
PCH
PCIe 2.0 x 1
eSPI RGMII 1 GB-T
DMI3 RGMII/MDI (Mgmt)
BMC
PCIe 3.0 x4 SATA 3.0 x4
Mini Storage

(types vary with mLOM/OCP 3.0 module)


Module USB 2.0 x 1
DMI3 (x4)
(two M.2 SSDs)

. . . . . . . . . . . .
DDR5 DIMMs

Network connectors
A1 A2

Chan A
DMI3
B1 B2 mLOM/OCP
Chan B Module
PCIe 4.0 x 16
C1 C2
Chan C PCIe 4.0 x 16
CPU1
D1 D2 PCIe 5.0 x 16
Chan D
4th Gen Intel® Xeon®
E1 E2 Scalable Processor
Chan E (Sapphire Rapids) Front Panel
KVM
Connector
F1 F2

Chan F
USB 2.0 x 2
G1 G2
1 VGA
UCSC-C220-M7N Front drives Chan G
1 Serial COM
1-10
all NVMe H1 H2
CPU2 Chan H
NVMe PCIe 4.0 x 16
1
2 .
3 . UPI (3x 16 GT/s)
DDR5 DIMMs PCIe Riser 1A (1 HH slot)
4 .
.
Drive CPU2 A1 A2
Slot 1
PCIe 4.0 x 8 PCIe 4.0 x 16
5 . Backplane Chan A
6 .
. B1 B2
PCIe Riser 2A (1 HH slot)
7 . Slot 1
Chan B PCIe 4.0 x 16 3 HH Gen 4 Riser Configuration
8
9 CPU1 C1 C2
NVMe PCIe Riser 3A (1 HH slot)
PCIe 4.0 x 16 Chan C
10
CPU2 PCIe 4.0 x 16 Slot 1
D1 D2

Chan D
4th Gen Intel® Xeon® PCIe 5.0 x 16

E1 E2 Scalable Processor PCIe Riser 1B (1 HH slot)

Chan E (Sapphire Rapids) PCIe 5.0 x 16 Slot 1

F1 F2
PCIe Riser 2B (1 HH slot) 2 HH Gen 5 Riser Configuration
Chan F
PCIe 5.0 x 16 Slot 1
G1 G2

Chan G

H1 H2

Chan H PCIe 5.0 x 16 PCIe Riser 1C (1 FH slot)

Slot 1

PCIe Riser 3C (1 FH slot) 2 FH Riser Configuration


PCIe 5.0 x 16
Slot 1

Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model) 60
SUPPLEMENTAL MATERIAL

Chassis
Figure 7 and Figure 8 shows the Internal views of the C220 M7 chassis with the top cover removed.

Figure 7 C220 M7 SFF With Top Cover Off (full-height, full-width PCIe cards)
1 2 3 4 5 6 7 8

10

11

309137
13 3 12

1 Front-loading drive bays 2 M7 modular RAID card (or SATA Interposer)


3 Cooling fan modules (eight) 4 Supercap module mounting bracket
Each fan is hot-swappable
5 DIMM sockets on motherboard, 32 total, 16 per 6 Motherboard CPU2 socket
CPU
CPUs are arranged in groups of eight sockets
above the top CPU and below the bottom CPU,
and 16 sockets between the CPUs.
7 M.2 module connector, supporting a 8 Two power supplies
boot-optimized RAID controller with
connectors for up to two SATA M.2 SSDs.
9 PCIe riser 3 10 PCIe riser 1
Accepts 1 full height, full width PCIe riser card Accepts 1 full height, full width PCIe riser card
11 Modular LOM (mLOM) card bay on chassis 12 Motherboard CPU1 socket
floor(x16 PCIe lane) Connector shown, but the
card bay sits below PCIe riser 1.
13 Front Panel Controller board -

61 Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model)
SUPPLEMENTAL MATERIAL

Figure 8 C220 M7 SFF With Top Cover Off (full-height, half-width PCIe cards)
1 2 3 4 5 6 7 8

10

11
12

309138
14 3 13

1 Front-loading drive bays 2 M7 modular RAID card (or SATA Interposer)


3 Cooling fan modules (eight) 4 Supercap module mounting bracket
Each fan is hot-swappable
5 DIMM sockets on motherboard, 32 total, 16 6 Motherboard CPU2 socket
per CPU
CPUs are arranged in groups of eight sockets
above the top CPU and below the bottom
CPU, and 16 sockets between the CPUs.
7 M.2 module connector, supporting a 8 Two power supplies
boot-optimized RAID controller with
connectors for up to two SATA M.2 SSDs.
9 PCIe riser 3 10 PCIe riser 2
Accepts 1 half height, half width PCIe riser Accepts 1 half height, half width PCIe riser
card card
11 PCIe riser 1 12 Modular LOM (mLOM)/OCP 3.0 card bay on
chassis floor (x16 PCIe lane) Connector
Accepts 1 half height, half width PCIe riser
card shown, but the card bay sits below PCIe
riser slot 1.
13 Motherboard CPU1 socket 14 Front Panel Controller board

Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model) 62
SUPPLEMENTAL MATERIAL

Risers
Figure 9 shows the locations of the PCIe riser connectors on the C220 M7 SFF motherboard. The allowed
configurations are:

■ Half-height risers in riser 1 connector, riser 2 connector, and riser 3 connector, or


■ Full-height risers in riser 1 connector and riser 3 connector.

See Figure 10 and Figure 11 for more details.

Figure 9 C220 M7 SFF Riser Connector Locations


C220 M7 SFF Motherboard

Riser 3 Connector

Riser 2 Connector

Riser 1 Connector

63 Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model)
SUPPLEMENTAL MATERIAL

Figure 10 shows three half-height risers plugged into their respective connectors.

Figure 10 C220 M7 SFF With Three Half-Height Risers Plugged In


C220 M7 SFF Motherboard

Riser 3 Connector

Half-Height Riser 3

Half-Height Riser 2

Half-Height Riser 1

Riser 1 Connector
Riser 2 Connector

Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model) 64
SUPPLEMENTAL MATERIAL

Figure 11 shows two full-height risers plugged in. Note that riser 1 is plugged into the riser 1 connector and
riser 2 is plugged into the riser 3 connector. Riser 2 connector is not used.

Figure 11 C220 M7 SFF With Two Full-Height Risers Plugged In


C220 M7 SFF Motherboard

Riser 3 Connector

Full-Height Riser 2

FullHeight Riser 1

Riser 1 Connector

65 Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model)
SUPPLEMENTAL MATERIAL

Serial Port Details


The pinout details of the rear RJ-45 serial port connector are shown in Figure 12.

Figure 12 Serial Port (Female RJ-45 Connector) Pinout


Serial Port (RJ-45 Female Connector)

Pin Signal
1 RTS (Request to Send)
2 DTR (Data Terminal Ready)
3 TxD (Transmit Data)
4 GND (Signal Ground)
5 GND (Signal Ground)
6 RxD (Receive Data)
7 DSR (Data Set Ready)
8 CTS (Clear to Send)

KVM Cable
The KVM cable provides a connection into the server, providing a DB9 serial connector, a VGA connector for
a monitor, and dual USB ports for a keyboard and mouse. With this cable, you can create a direct
connection to the operating system and the BIOS running on the server.
The KVM cable ordering information is listed in Table 37.

Table 37 KVM Cable

Product ID (PID) PID Description


N20-BKVM KVM cable for UCS Server console port

Figure 13 KVM Cable

1 Connector (to server front panel) 3 VGA connector (for a monitor)

2 DB-9 serial connector 4 Two-port USB connector (for a mouse and keyboard)

Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model) 66
UPGRADING or REPLACING CPUs and Memory

UPGRADING or REPLACING CPUs and Memory


■ Refer to Cisco UCS C220 M7 Server Installation and Service Guide to upgrading or replacing the CPUs
■ Refer to Cisco UCS C220 M7 Server Installation and Service Guide to upgrading or replacing the Memory

67 Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model)
SPARE PARTS

SPARE PARTS
This section lists the upgrade and service-related parts for the UCS C220 M7 server. Some of these parts are
configured with every server.

NOTE: Some spare parts you order may also require accessories for full
functionality. For example, drives or RAID controllers may need accompanying
cables. CPUs may need heatsinks, thermal paste, and installation tools. The spares
and their accessory parts are listed in Table 38.

Table 38 Spare Parts

Product ID (PID) Description


Risers
Riser 1 Option
UCSC-RIS1A-22XM7= UCS C-Series M7 1U Riser 1A PCIe Gen4 x16 HH
UCSC-RIS1B-22XM7= UCS C-Series M7 1U Riser 1B PCIe Gen5 x16 HH
UCSC-RIS1C-22XM7= UCS C-Series M7 1U Riser 1C PCIe Gen5 x16 FH
Riser 2 Option
UCSC-RIS2A-22XM7= UCS C-Series M7 1U Riser 2A PCIe Gen4 x16 HH
UCSC-RIS2B-22XM7= UCS C-Series M7 1U Riser 2B PCIe Gen5 x16 HH
Riser 3 Option
UCSC-RIS3A-22XM7= UCS C-Series M7 1U Riser 3A PCIe Gen4 x16 HH (CPU2)
UCSC-RIS3C-22XM7= UCS C-Series M7 1U Riser 3C PCIe Gen5 x16 FH (CPU2)
Riser Blank
UCSC-FBRS2-C220M7= C220 M7 Riser2 HH Filler Blank
UCSC-FBRS-C220-D= C220M7 HH Riser3 blank
UCSC-FBRSF-220M7= C220 M7 Riser FH Filler Blank
CPUs

Note: If you are ordering a second CPU, see the CPU Accessories section in this table for additional parts
you may need to order for the second CPU.
5th Gen. CPUs
8000 Series Processors
UCS-CPU-I8581V=
UCS-CPU-I8571N=
UCS-CPU-I8562Y+=
UCS-CPU-I8558U=
6000 Series Processors
UCS-CPU-I6554S=
UCS-CPU-I6548Y+=
UCS-CPU-I6548N=
UCS-CPU-I6544Y=
UCS-CPU-I6542Y=

Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model) 68
SPARE PARTS

Table 38 Spare Parts

Product ID (PID) Description


UCS-CPU-I6538Y+=
UCS-CPU-I6538N=
UCS-CPU-I6534=
UCS-CPU-I6530=
UCS-CPU-I6526Y=
5000 Series Processors
UCS-CPU-I5520+=
UCS-CPU-I5515+=
UCS-CPU-I5512U=
4000 Series Processors
UCS-CPU-I4516Y+=
UCS-CPU-I4514Y=
UCS-CPU-I4510T=
UCS-CPU-I4510=
UCS-CPU-I4509Y=
3000 Series Processors
UCS-CPU-I3508U=
4th Gen. CPUs
8000 Series Processors
UCS-CPU-I8471N=
UCS-CPU-I8470N=
UCS-CPU-I8462Y+=
UCS-CPU-I8461V=
UCS-CPU-I8460Y+=
UCS-CPU-I8454H=
UCS-CPU-I8452Y=
UCS-CPU-I8450H=
UCS-CPU-I8444H=
6000 Series Processors
UCS-CPU-I6454S=
UCS-CPU-I6448Y=
UCS-CPU-I6448H=
UCS-CPU-I6444Y=
UCS-CPU-I6442Y=
UCS-CPU-I6438Y+=
UCS-CPU-I6438N=

69 Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model)
SPARE PARTS

Table 38 Spare Parts

Product ID (PID) Description


UCS-CPU-I6438M=
UCS-CPU-I6434H=
UCS-CPU-I6434=
UCS-CPU-I6430=
UCS-CPU-I6428N=
UCS-CPU-I6426Y=
UCS-CPU-I6421N=
UCS-CPU-I6418H=
UCS-CPU-I6416H=
UCS-CPU-I6414U=
5000 Series Processors
UCS-CPU-I5420+=
UCS-CPU-I5418Y=
UCS-CPU-I5418N=
UCS-CPU-I5416S=
UCS-CPU-I5415+=
UCS-CPU-I5412U=
UCS-CPU-I5411N=
4000 Series Processors
UCS-CPU-I4416+=
UCS-CPU-I4410Y=
UCS-CPU-I4410T=
3000 Series Processors
UCS-CPU-I3408U=
CPU Accessories
UCSC-HSLP-C220M7= UCS C220 M7 Heatsink for & C240 GPU Heatsink

Note: Order this


Heatsink, if you are
adding additional
CPU/spare CPU

Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model) 70
SPARE PARTS

Table 38 Spare Parts

Product ID (PID) Description


UCS-CPU-TIM= Single CPU thermal interface material syringe for M5 server HS seal1

Note: This part is


included with the
purchase of spare
CPU.Can be ordered
separately.
UCS-M6-CPU-CAR= Spare CPU Carrier for M7

Note: This part is


included with the
purchase of spare
CPU.Can be ordered
separately.
UCSX-HSCK= UCS CPU/Heatsink Cleaning Kit, for up to 4 CPU/heatsink sets

Note: This part is


included with the
purchase of spare
CPU.Can be ordered
separately.
UCS-CPUAT= CPU Assembly Tool for Servers

Note: This part is


included with the
purchase of spare
CPU.Can be ordered
separately.
UCSC-FAN-C22XM7= UCS C-Series M7 1U Fan
Memory
UCS-MRX16G1RE1= 16GB DDR5-4800 RDIMM 1Rx8 (16Gb)
UCS-MRX32G1RE1= 32GB DDR5-4800 RDIMM 1Rx4 (16Gb)
UCS-MRX64G2RE1= 64GB DDR5-4800 RDIMM 2Rx4 (16Gb)
UCS-MR128G4RE1= 128GB DDR5-4800 RDIMM 4Rx4 (16Gb)
UCS-MRX16G1RE3= 16GB DDR5-5600 RDIMM 1Rx8 (16Gb)
UCS-MRX32G1RE3= 32GB DDR5-5600 RDIMM 1Rx4 (16Gb)
UCS-MRX48G1RF32= 48GB DDR5-5600 RDIMM 1Rx4 (24Gb)
UCS-MRX64G2RE3= 64GB DDR5-5600 RDIMM 2Rx4 (16Gb)
UCS-MRX96G2RF3= 96GB DDR5-5600 RDIMM 2Rx4 (24Gb)
UCS-MR128G4RE3= 128GB DDR5-5600 RDIMM 4Rx4 (16Gb)

71 Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model)
SPARE PARTS

Table 38 Spare Parts

Product ID (PID) Description


UCS-DDR5-BLK= UCS DDR5 DIMM Blanks

Note: Order this DIMM


Blank, if you are not
using DIMM slots. Any
empty DIMM slot must
be populated with a
DIMM blank to maintain
proper cooling airflow.
RAID Controllers

Note: When ordering additional RAID controllers, you may need to order a cable/supercap to connect
from the RAID controller to the motherboard. See the RAID Controller Accessories section in this table.
UCSC-RAID-HP= Cisco Tri-Mode 24G SAS RAID Controller w/4GB Cache
UCSC-RAID-HP= accessories (note: the below accessories only required if it is not in the system
configuration. Must select all option within a single accessory or OPTOUT PID.
UCS-SCAP-D= M6 SuperCap
CBL-SCAP-C220-D= C220/C240M6 1U/2U Super Cap cable
CBL-SAS-Y-C220M7= C220M7 SAS CABLE; MB CPU1 P-1 to HP RAID Controller
UCSC-HPBKT-22XM7= UCS C-Series M7 1U HP RAID Controller Bracket
UCSC-OPTOUT= Opt out from Ordering Accessories
UCSC-RAID-T-D= Cisco M6 12G SAS RAID Controller with 4GB FBWC (16 Drives)
UCSC-RAID-T-D= accessories (note: the below accessories only required if it is not in the system
configuration. Must select all option within a single accessory or OPTOUT PID.
UCS-SCAP-D= M6 SuperCap
CBL-SCAP-C220-D= C220/C240M6 1U/2U Super Cap cable
CBL-SAS-C220M7= C220M7 SAS CABLE; MB CPU1 P-1 to SAS RAID Controller
UCSC-RDBKT-22XM7= UCS C-Series M7 1U RAID/HBA Controller Bracket
UCSC-OPTOUT= Opt out from Ordering Accessories
UCSC-SAS-T-D= Cisco M6 12G SAS HBA for (16 Drives)
UCSC-SAS-T-D= accessories (note: the below accessories only required if it is not in the system
configuration. Must select all option within a single accessory or OPTOUT PID.
UCSC-RDBKT-22XM7= UCS C-Series M7 1U RAID/HBA Controller Bracket
CBL-SAS-C220M7= C220M7 SAS CABLE; MB CPU1 P-1 to SAS RAID Controller
Controller for External Drives
UCSC-9500-8E-D= Cisco 12G 9500-8e 12G SAS HBA for external JBOD attach
SATA Interposer
UCSC-SATAIN-220M7= UCS C220 M7 SATA Interposer Board (for control of up to 8 SATA-only drives
using AHCI)

Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model) 72
SPARE PARTS

Table 38 Spare Parts

Product ID (PID) Description


Drives

Note: When ordering additional SAS/SATA or NVMe front or rear drives, you may need to order a cable to
connect from the drive to the motherboard. See the Drive Cables section in this table.
PCIe/NVMe SFF (2.5-inch) SFF drives
UCS-NVMEXP-I400-D= 400GB 2.5in U.2 Intel P5800X Optane NVMe Extreme Perform SSD
UCS-NVMEXP-I800-D= 800GB 2.5in U.2 Intel P5800X Optane NVMe Extreme Perform SSD
UCS-NVME4-1600-D= 1.6TB 2.5in U.2 P5620 NVMe High Perf High Endurance
UCS-NVME4-1920-D= 1.9TB 2.5in U.2 P5520 NVMe High Perf Medium Endurance
UCS-NVME4-3200-D= 3.2TB 2.5in U.2 P5620 NVMe High Perf High Endurance
UCS-NVME4-3840-D= 3.8TB 2.5in U.2 P5520 NVMe High Perf Medium Endurance
UCS-NVME4-6400-D= 6.4TB 2.5in U.2 P5620 NVMe High Perf High Endurance
UCS-NVME4-7680-D= 7.6TB 2.5in U.2 P5520 NVMe High Perf Medium Endurance
UCS-NVME4-15360-D= 15.3TB 2.5in U.2 P5520 NVMe High Perf Medium Endurance
UCS-NVMEQ-1536-D= 15.3TB 2.5in U.2 P5316 NVMe High Perf Low Endurance
UCS-NVMEG4-M960-D= 960GB 2.5in U.3 Micron P7450 NVMe High Perf Medium Endurance
UCS-NVMEG4-M1920D= 1.9TB 2.5in U.3 Micron P7450 NVMe High Perf Medium Endurance
UCS-NVMEG4-M3840D= 3.8TB 2.5in U.3 Micron P7450 NVMe High Perf Medium Endurance
UCS-NVMEG4-M7680D= 7.6TB 2.5in U.3 Micron P7450 NVMe High Perf Medium Endurance
UCS-NVMEG4-M1536D= 15.3TB 2.5in U.3 MicronP7450 NVMe High Perf Medium Endurance
UCS-NVMEG4-M1600D= 1.6TB 2.5in U.3 Micron P7450 NVMe High Perf High Endurance
UCS-NVMEG4-M3200D= 3.2TB 2.5in U.3 Micron P7450 NVMe High Perf High Endurance
UCS-NVMEG4-M6400D= 6.4TB 2.5in U.3 Micron P7450 NVMe High Perf High Endurance
HDDs
HDDs (10K RPM)
UCS-HD600G10KJ4-D= 600 GB 12G SAS 10K RPM SFF HDD
UCS-HD12TB10KJ4-D= 1.2 TB 12G SAS 10K RPM SFF HDD
UCS-HD18TB10KJ4-D= 1.8 TB 12G SAS 10K RPM SFF HDD (4K)
UCS-HD24TB10KJ4-D= 2.4 TB 12G SAS 10K RPM SFF HDD (4K)
Enterprise Performance SAS/SATA SSDs (High endurance, supports up to 10X or 3X DWPD (drive
writes per day))
SATA
UCS-SD480G63XEP-D= 480 GB 2.5in Enterprise Performance 6G SATA SSD(3X endurance)
UCS-SD960G63XEP-D= 960 GB 2.5in Enterprise performance 6G SATA SSD(3X endurance)
UCS-SD19T63X-EP-D= 1.9 TB 2.5in Enterprise performance 6G SATA SSD(3X endurance)
UCS-SD38T63X-EP-D= 3.8 TB 2.5in Enterprise performance 6G SATA SSD(3X endurance)
UCS-SD480GBM3XEPD= 480GB SATA SSD 3DWPD
UCS-SD960GBM3XEPD= 960GB SATA SSD 3DWPD
UCS-SD19TBM3XEP-D= 1.9TB SATA SSD 3DWPD

73 Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model)
SPARE PARTS

Table 38 Spare Parts

Product ID (PID) Description


SAS
UCS-SD800GK3XEP-D= 800 GB 2.5in Enterprise Performance 12G SAS SSD(3X endurance)
UCS-SD16TK3X-EP-D= 1.6 TB 2.5in Enterprise Performance 12G SAS SSD(3X endurance)
UCS-SD32TK3X-EP-D= 3.2 TB 2.5in Enterprise Performance 12G SAS SSD(3X endurance)
UCS-SD16TKA3XEP-D= 1.6TB 2.5in Enterprise Performance 12G SAS SSD(3X endurance)
UCS-SD32TKA3XEP-D= 3.2TB 2.5in Enterprise Performance 12G SAS SSD(3X endurance)
UCS-SD64TS3XEP-D= 6.4TB 2.5in Enterprise Performance 12G SAS SSD(3X endurance)
Enterprise Value SAS/SATA SSDs (Low endurance, supports up to 1X DWPD (drive writes per day))
SATA
UCSSD480G6I1XEV-D= 480GB 2.5 inch Enterprise Value 6G SATA SSD
UCSSD960G6S1XEV-D= 960GB 2.5 inch Enterprise Value 6G SATA SSD
UCSSD960G6I1XEV-D= 960GB 2.5 inch Enterprise Value 6G SATA SSD
UCS-SD19T6S1XEV-D= 1.9TB 2.5 inch Enterprise Value 6G SATA SSD
UCS-SD38T6S1XEV-D= 3.8 TB 2.5 inch Enterprise Value 6G SATA SSD
UCS-SD38T6I1XEV-D= 3.8TB 2.5 inch Enterprise Value 6G SATA SSD
UCS-SD76T6S1XEV-D= 7.6TB 2.5 inch Enterprise Value 6G SATA SSD
UCS-SD240GBM1XEVD= 240GB SATA SSD 1DWPD
UCS-SD480GBM1XEVD= 480GB SATA SSD 1DWPD
UCS-SD960GBM1XEVD= 960GB SATA SSD 1DWPD
UCS-SD16TBM1XEV-D= 1.6GB SATA SSD 1DWPD
UCS-SD19TBM1XEV-D= 1.9TB SATA SSD 1DWPD
UCS-SD38TBM1XEV-D= 3.8TB SATA SSD 1DWPD
UCS-SD76TBM1XEV-D= 7.6TB SATA SSD 1DWPD
UCS-SDB960SA1VD= 960GB 2.5in 6G SATA Enter Value 1X Samsung G1PM893A SSD
UCS-SDB1T9SA1VD= 1.9TB 2.5in 6G SATA Enter Value 1X Samsung G1PM893A SSD
UCS-SDB3T8SA1VD= 3.8TB 2.5in 6G SATA Enter Value 1X Samsung G1PM893A SSD
UCS-SDB7T6SA1VD= 7.6TB 2.5in 6G SATA Enter Value 1X Samsung G1PM893A SSD
SAS
UCS-SD960GK1XEV-D= 960GB 2.5 inch Enterprise Value 12G SAS SSD
UCS-SD19TK1X-EV-D= 1.9TB 2.5 inch Enterprise Value 12G SAS SSD
UCS-SD38TK1X-EV-D= 3.8TB 2.5 inch Enterprise Value 12G SAS SSD
UCS-SD76TK1X-EV-D= 7.6TB 2.5 inch Enterprise Value 12G SAS SSD
UCS-SD15TK1X-EV-D= 15.3TB 2.5 inch Enterprise Value 12G SAS SSD
UCS-SD19TKA1XEV-D= 1.9TB 2.5 inch Enterprise Value 12G SAS SSD
UCS-SD38TKA1XEV-D= 3.8TB 2.5 inch Enterprise Value 12G SAS SSD
UCS-SD76TKA1XEV-D= 7.6TB 2.5 inch Enterprise Value 12G SAS SSD
UCS-SD76TS1X-EV-D= 7.6TB 2.5 inch Enterprise Value 12G SAS SSD
UCS-SD15TKA1XEV-D= 15.3TB 2.5 inch Enterprise Value 12G SAS SSD
Self-Encrypted Drives (SED) (1X or 3X)

Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model) 74
SPARE PARTS

Table 38 Spare Parts

Product ID (PID) Description


SATA
SAS
UCS-SD800GBKNK9-D= 800GB Enterprise Performance SAS SSD (3X DWPD, SED) FIPS140-2
UCS-SD960GBKNK9-D= 960GB Enterprise Value SAS SSD (1X DWPD, SED) FIPS140-2
UCS-SD16TBKNK9-D= 1.6TB Enterprise performance SAS SSD (3X DWPD, SED) FIPS140-2
UCS-SD38TBKNK9-D= 3.8TB Enterprise Value SAS SSD (1X DWPD, SED) FIPS140-2
UCS-SD76TBKNK9-D= 7.6TB Enterprise value SAS SSD (1X DWPD, SED-FIPS) FIPS140-2
UCS-SD16TBKANK9-D= 1.6TB 2.5" Enterprise performance 12GSAS SSD(3DWPD,SED-FIPS) FIPS140-2
UCS-SD38TBKANK9-D= 3.8TB 2.5" Enterprise value 12G SAS SSD (1DWPD, SED-FIPS) FIPS140-2
UCS-SD76TBKANK9-D= 7.6TB Enterprise value SAS SSD (1DWPD, SED-FIPS)
FIPS140-2
UCS-SD960GM2NK9-D= 960GB SED SSD 1DWPD
UCS-SD19TEM2NK9-D= 1.9TB SED SSD 1DWPD
UCS-SD38TEM2NK9-D= 3.8TB SED SSD 1DWPD
UCS-SD76TEM2NK9-D= 7.6TB SED SSD 1DWPD
Drive Cables
CBL-SATA-C220-D= SATA cable C220M7 (1U)

Note: Order this cable


if you are adding a
front SAS/SATA drive.
CBL-FNVME-C220M7= C220M7 NVMe CABLE; MB to BP (NVMe 1-4) Y-CBL

Note: You may need to


order this cable if you
are adding a front
NVMe drive to
UCSC-C220-M7S
Drive Blanking Panel
UCSC-BBLKD-M7 UCS C-Series M7 SFF drive blanking panel
PCIe Cards
Modular LAN on Motherboard (mLOM)
UCSC-M-V5Q50G-D= Cisco UCS VIC 15428 Quad Port 10/25G/50G CNA MLOM
UCSC-M-V5D200G-D= Cisco UCS VIC 15238 Dual Port 40/100/200G CNA MLOM
UCSC-M-V5Q50GV2-D= Cisco UCS VIC 15427 Quad Port CNA MLOM with Secure Boot
UCSC-M-V5D200GV2D= Cisco UCS VIC 15238 Dual Port CNA MLOM with Secure Boot
Open Compute Project (OCP)
UCSC-O-ID10GC-D= Intel X710T2LOCPV3G1L 2x10GbE RJ45 OCP 3.0 NIC
Virtual Interface Cards (VICs)

75 Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model)
SPARE PARTS

Table 38 Spare Parts

Product ID (PID) Description


UCSC-P-V5Q50G-D= Cisco UCS VIC 15425 Quad Port 10/25/50G CNA PCIE
UCSC-P-V5D200G-D= Cisco UCS VIC 15235 Dual Port 40/100/200G CNA PCIE
Network Interface Cards (NICs)
1GbE NICs
UCSC-P-IQ1GC= Cisco-Intel I710-T4L 4x1GBASE-T NIC
10GbE NICs
UCSC-PCIEID10GF-D= Intel X710-DA2 Dual Port 10Gb SFP+ NIC
UCSC-PCIEIQ10GF-D= Intel X710 quad-port 10G SFP+ NIC
UCSC-P-ID10GC-D= Cisco-Intel X710T2LG 2x10GBE RJ45 PCIe NIC
UCSC-P-IQ10GC-D= Cisco-Intel X710T4LG 4x10GBE RJ45 PCIe NIC
25GbE NICs
UCSC-P-I8D25GF-D= Cisco-Intel E810XXVDA2 2x25/10GBE SFP28 PCIe NIC
UCSC-P-I8Q25GF-D= Cisco-Intel E810XXVDA4L 4x25/10GBE SFP28 PCIe NIC
UCSC-P-N6D25GF-D= Cisco-NVDA MCX631102AS-ADAT CX6Lx 2x25GbE SFP28 x8 PCIe NIC
UCSC-P-N7Q25GF= MCX713104AS-ADAT: CX-7 4x25GbE SFP56 PCIe Gen4x16, VPI NIC
100GbE NICs
UCSC-P-MCD100GF-D= Cisco-MLNX MCX623106AC-CDAT 2x100GbE QSFP56 PCIe NIC (with Crypto)
UCSC-P-MDD100GF-D= Cisco-MLNX MCX623106AS-CDAT 2x100GbE QSFP56 PCIe NIC
UCSC-P-I8D100GF-D= Cisco-Intel E810CQDA2 2x100 GbE QSFP28 PCIe NIC
200GbE NICs
UCSC-P-N7D200GF= MCX755106AS-HEAT:CX-7 2x200GbE QSFP112 PCIe Gen5x16, VPI NIC
Host Bus Adapters (HBAs)
UCSC-P-Q6D32GF-D= Cisco-QLogic QLE2772 2x32GFC Gen 6 Enhanced PCIe HBA
UCSC-P-B7D32GF-D= Cisco-Emulex LPe35002-M2-2x32GFC Gen 7 PCIe HBA
UCSC-PCIEQD16GF-D= Qlogic QLE2692 dual-port 16G FC HBA
UCSC-PCIEBD16GF-D= Emulex LPe31002 dual port 16G FC HBA
UCSC-P-Q7D64GF= Cisco-QLogic QLE2872, 2x64GFC Gen 7 PCIe HBA
External Storage HBA
UCSC-9500-8E-D= Cisco 12G 9500-8e 12G SAS HBA for external JBOD attach
GPU
UCSC-GPU-L4= NVIDIA L4:70W, 24GB, 1-slot HHHL GPU
UCSC-GPU-FLEX140= Intel GPU Flex 140, Gen4x8, HHHL, 75W PCIe
Power Supply
PSU (Input High Line 210VAC)
UCSC-PSU1-770W-D= UCS C-series 770W AC PSU (Not EU/UK Lot 9 Compliant)
UCSC-PSUV21050D-D= Cisco UCS 1050W -48V DC Power Supply for Rack Server Platinum
UCSC-PSUV21050DCI= 1050W -48V DC power supply for C-Series servers (India)
UCSC-PSU1-1200W-D= 1200W Titanium power supply for C-Series Servers Titanium

Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model) 76
SPARE PARTS

Table 38 Spare Parts

Product ID (PID) Description


UCSC-PSU1-1600W-D= UCS 1600W AC PSU Platinum (Not EU/UK Lot 9 Compliant)
UCSC-PSU1-2300W-D= 2300W Power supply for C-series servers Titanium
PSU (Input Low Line 110VAC)
UCSC-PSU1-770W-D= UCS C-series 770W AC PSU (Not EU/UK Lot 9 Compliant)
UCSC-PSU1-1200W-D= 1200W Titanium power supply for C-Series Servers Titanium
UCSC-PSU1-2300W-D= 2300W Power supply for C-series servers Titanium
Power Cords
NO-POWER-CORD= ECO friendly green option, no power cable will be shipped
CAB-48DC40A8AWG-D= C-Series -48VDC PSU Power Cord, 3.5M, 3 Wire, 8AWG, 40A
CAB-N5K6A-NA= Power Cord, 200/240V 6A, North America
CAB-AC-L620-C13-D= AC Power Cord, NEMA L6-20 - C13, 2M/6.5ft
CAB-C13-CBN= CABASY,WIRE,JUMPER CORD, 27" L, C13/C14, 10A/250V
CAB-C13-C14-2M= CABASY,WIRE,JUMPER CORD, PWR, 2 Meter, C13/C14,10A/250V
CAB-C13-C14-AC= CORD,PWR,JMP,IEC60320/C14,IEC6 0320/C13, 3.0M
CAB-250V-10A-AR= Power Cord, 250V, 10A, Argentina
CAB-9K10A-AU= Power Cord, 250VAC 10A 3112 Plug, Australia
CAB-250V-10A-CN= AC Power Cord - 250V, 10A - PRC
CAB-9K10A-EU= Power Cord, 250VAC 10A CEE 7/7 Plug, EU
CAB-250V-10A-ID= Power Cord, 250V, 10A, India
CAB-C13-C14-3M-IN= Power Cord Jumper, C13-C14 Connectors, 3 Meter Length, India
CAB-C13-C14-IN= Power Cord Jumper,C13-C14 Connectors,1.4 Meter Length, India
CAB-250V-10A-IS= Power Cord, SFS, 250V, 10A, Israel
CAB-9K10A-IT= Power Cord, 250VAC 10A CEI 23-16/VII Plug, Italy
CAB-9K10A-SW= Power Cord, 250VAC 10A MP232 Plug, Switzerland
CAB-9K10A-UK= Power Cord, 250VAC 10A BS1363 Plug (13 A fuse), UK
CAB-9K12A-NA= Power Cord, 125VAC 13A NEMA 5-15 Plug, North America
CAB-250V-10A-BR = Power Cord - 250V, 10A - Brazil
CAB-C13C142M-JP-D= Power Cord C13-C14, 2M/6.5ft Japan PSE mark
CAB-9K10A-KOR= Power Cord, 125VAC 13A KSC8305 Plug, Korea
CAB-ACTW= AC Power Cord (Taiwan), C13, EL 302, 2.3M
CAB-JPN-3PIN= Japan, 90-125VAC 12A NEMA 5-15 Plug, 2.4m
CAB-48DC40A-INT-D= C-Series -48VDC PSU PWR Cord, 3.5M, 3 Wire, 8AWG, 40A (INT)
CAB-48DC-40A-AS-D= C-Series -48VDC PSU PWR Cord, 3.5M, 3Wire, 8AWG, 40A (AS/NZ)
CAB-C19-CBN= Cabinet Jumper Power Cord, 250 VAC 16A, C20-C19 Connectors
CAB-S132-C19-ISRL= S132 to IEC-C19 14ft Israeli
CAB-IR2073-C19-AR= IRSM 2073 to IEC-C19 14ft Argen
CAB-BS1363-C19-UK= BS-1363 to IEC-C19 14ft UK
CAB-SABS-C19-IND= SABS 164-1 to IEC-C19 India

77 Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model)
SPARE PARTS

Table 38 Spare Parts

Product ID (PID) Description


CAB-C2316-C19-IT= CEI 23-16 to IEC-C19 14ft Italy
CAB-L520P-C19-US = NEMA L5-20 to IEC-C19 6ft US
CAB-US515P-C19-US= NEMA 5-15 to IEC-C19 13ft US
CAB-US520-C19-US= NEMA 5-20 to IEC-C19 14ft US
CAB-US620P-C19-US = NEMA 6-20 to IEC-C19 13ft US
Rail Kit
UCSC-RAIL-D= Ball Bearing Rail Kit for C220 & C240 M6/M7 rack servers
UCSC-RAIL-NONE-D= No rail kit option
UCSC-CMA-C220-D= Reversible CMA for C220 M6/M7 ball bearing rail kit
Security
UCSC-DLOM-01-D= Dedicated Mode BIOS setting for C-Series Servers
UCSC-CCARD-01-D= Cisco Card Mode BIOS setting for C-Series Servers
UCSX-TPM-002C-D= Trusted Platform Module 2.0 for UCS servers
UCSC-INT-SW02-D= C220 and C240 M7 Chassis Intrusion Switch
UCSX-TPM-OPT-OUT-D= OPT OUT, TPM 2.0, TCG, FIPS140-2, CC EAL4+ Certified
Security
UCSC-BZL-C220-D= C220 M7 Security Bezel
M.2 SATA SSD and M.2 RAID controller
UCS-M2-I240GB-D= 240GB SATA M.2 SSD
UCS-M2-I480GB-D= 480GB SATA M.2 SSD
UCS-M2-240G-D= 240GB M.2 SATA Micron G2 SSD
UCS-M2-960G-D= 960GB M.2 SATA Micron G2 SSD
UCS-M2-HWRAID-D= Cisco Boot optimized M.2 RAID controller (holds up to two M.2 SATA SSDs)
M.2 NVMe and M.2 RAID controller
UCS-NVM2-400GB= 400GB M.2 Boot NVMe
UCS-NVM2-960GB= 960GB M.2 Boot NVMe
UCS-M2-NVRAID= Cisco M.2 NVMe BOOT RAID Controller (HHHL)
Operating system and Software
VMware vCenter
VMW-VCS-STD-D1A = VMware vCenter 7 Server Standard, 1 yr support required
VMW-VCS-STD-D3A= VMware vCenter 7 Server Standard, 3 yr support required
VMW-VCS-STD-D5A= VMware vCenter 7 Server Standard, 5 yr support required
VMW-VCS-FND-D1A= VMware vCenter Server 7 Foundation (4 Host), 1 yr supp reqd
VMW-VCS-FND-D3A= VMware vCenter Server 7 Foundation (4 Host), 3 yr supp reqd
VMW-VCS-FND-D5A= VMware vCenter Server 7 Foundation (4 Host), 5 yr supp reqd
Microsoft Windows Server
MSWS-22-ST16CD = Windows Server 2022 Standard (16 Cores/2 VMs)
MSWS-22-ST16CD-NS= Windows Server 2022 Standard (16 Cores/2 VMs) - No Cisco SVC

Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model) 78
SPARE PARTS

Table 38 Spare Parts

Product ID (PID) Description


MSWS-22-DC16CD= Windows Server 2022 Data Center (16 Cores/Unlimited VMs)
MSWS-22-DC16CD-NS= Windows Server 2022 DC (16 Cores/Unlim VMs) - No Cisco SVC
MSWS-19-ST16CD= Windows Server 2019 Standard (16 Cores/2 VMs)
MSWS-19-ST16CD-NS= Windows Server 2019 Standard (16 Cores/2 VMs) - No Cisco SVC
MSWS-19-DC16CD= Windows Server 2019 Data Center (16 Cores/Unlimited VMs)
MSWS-19-DC16CD-NS= Windows Server 2019 DC (16 Cores/Unlim VMs) - No Cisco SVC
Red Hat
RHEL-2S2V-D1A= Red Hat Enterprise Linux (1-2 CPU,1-2 VN); 1-Yr Support Req
RHEL-2S2V-D3A= Red Hat Enterprise Linux (1-2 CPU,1-2 VN); 3-Yr Support Req
RHEL-2S2V-D5A= Red Hat Enterprise Linux (1-2 CPU,1-2 VN); 5-Yr Support Req
RHEL-VDC-2SUV-D1A= RHEL for Virt Datacenters (1-2 CPU, Unlim VN) 1 Yr Supp Req
RHEL-VDC-2SUV-D3A= RHEL for Virt Datacenters (1-2 CPU, Unlim VN) 3 Yr Supp Req
RHEL-VDC-2SUV-D5A= RHEL for Virt Datacenters (1-2 CPU, Unlim VN) 5 Yr Supp Req
Red Hat Ent Linux/ High Avail/ Res Strg/ Scal
RHEL-2S2V-D1S= Red Hat Enterprise Linux (1-2 CPU,1-2 VN); Prem 1Yr SnS Reqd
RHEL-2S2V-D3S= Red Hat Enterprise Linux (1-2 CPU,1-2 VN); Prem 3Yr SnS Reqd
RHEL-2S-HA-D1S= RHEL High Availability (1-2 CPU); Premium 1-yr SnS Reqd
RHEL-2S-HA-D3S= RHEL High Availability (1-2 CPU); Premium 3-yr SnS Reqd
RHEL-2S-RS-D1S= RHEL Resilent Storage (1-2 CPU); Premium 1-yr SnS Reqd
RHEL-2S-RS-D3S= RHEL Resilent Storage (1-2 CPU); Premium 3-yr SnS Reqd
RHEL-VDC-2SUV-D1S= RHEL for Virt Datacenters (1-2 CPU, Unlim VN) 1 Yr SnS Reqd
RHEL-VDC-2SUV-D3S= RHEL for Virt Datacenters (1-2 CPU, Unlim VN) 3 Yr SnS Reqd
Red Hat SAP
RHEL-SAP-2S2V-D1S= RHEL for SAP Apps (1-2 CPU, 1-2 VN); Prem 1-Yr SnS Reqd
RHEL-SAP-2S2V-D3S= RHEL for SAP Apps (1-2 CPU, 1-2 VN); Prem 3-Yr SnS Reqd
RHEL-SAPSP-D3S= RHEL SAP Solutions Premium - 3 Years
RHEL-SAPSS-D3S= RHEL SAP Solutions Standard - 3 Years
VMware
VMW-VSP-STD-D1A= VMware vSphere 7 Std (1 CPU, 32 Core) 1-yr, Support Required
VMW-VSP-STD-D3A= VMware vSphere 7 Std (1 CPU, 32 Core) 3-yr, Support Required
VMW-VSP-STD-D5A= VMware vSphere 7 Std (1 CPU, 32 Core) 5-yr, Support Required
VMW-VSP-EPL-D1A= VMware vSphere 7 Ent Plus (1 CPU, 32 Core) 1Yr, Support Reqd
VMW-VSP-EPL-D3A= VMware vSphere 7 Ent Plus (1 CPU, 32 Core) 3Yr, Support Reqd
VMW-VSP-EPL-D5A= VMware vSphere 7 Ent Plus (1 CPU, 32 Core) 5Yr, Support Reqd
SUSE
SLES-2S2V-D1A= SUSE Linux Enterprise Svr (1-2 CPU,1-2 VM); 1-Yr Support Req
SLES-2S2V-D3A= SUSE Linux Enterprise Svr (1-2 CPU,1-2 VM); 3-Yr Support Req
SLES-2S2V-D5A= SUSE Linux Enterprise Svr (1-2 CPU,1-2 VM); 5-Yr Support Req
SLES-2SUVM-D1A= SUSE Linux Enterprise Svr (1-2 CPU,Unl VM) LP; 1Y Supp Req
SLES-2SUVM-D3A= SUSE Linux Enterprise Svr (1-2 CPU,Unl VM) LP; 3Y Supp Req
SLES-2SUVM-D5A= SUSE Linux Enterprise Svr (1-2 CPU,Unl VM) LP; 5Y Supp Req

79 Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model)
SPARE PARTS

Table 38 Spare Parts

Product ID (PID) Description


SLES-2S-LP-D1A= SUSE Linux Live Patching Add-on (1-2 CPU); 1yr Support Req
SLES-2S-LP-D3A= SUSE Linux Live Patching Add-on (1-2 CPU); 3yr Support Req
SLES-2S2V-D1S= SUSE Linux Enterprise Svr (1-2 CPU,1-2 VM); Prio 1-Yr SnS
SLES-2S2V-D3S= SUSE Linux Enterprise Svr (1-2 CPU,1-2 VM); Prio 3-Yr SnS
SLES-2S2V-D5S= SUSE Linux Enterprise Svr (1-2 CPU,1-2 VM); Prio 5-Yr SnS
SLES-2SUVM-D1S= SUSE Linux Enterprise Svr (1-2 CPU,Unl VM) LP; Prio 1Y SnS
SLES-2SUVM-D3S= SUSE Linux Enterprise Svr (1-2 CPU,Unl VM) LP; Prio 3Y SnS
SLES-2SUVM-D5S= SUSE Linux Enterprise Svr (1-2 CPU,Unl VM) LP; Prio 5Y SnS
SLES-2S-HA-D1S= SUSE Linux High Availability Ext (1-2 CPU); 1yr SnS
SLES-2S-HA-D3S= SUSE Linux High Availability Ext (1-2 CPU); 3yr SnS
SLES-2S-HA-D5S= SUSE Linux High Availability Ext (1-2 CPU); 5yr SnS
SLES-2S-GC-D1S= SUSE Linux GEO Clustering for HA (1-2 CPU); 1yr Sns
SLES-2S-GC-D3S= SUSE Linux GEO Clustering for HA (1-2 CPU); 3yr SnS
SLES-2S-GC-D5S= SUSE Linux GEO Clustering for HA (1-2 CPU); 5yr SnS
SLES-2S-LP-D1S= SUSE Linux Live Patching Add-on (1-2 CPU); 1yr SnS Required
SLES-2S-LP-D3S= SUSE Linux Live Patching Add-on (1-2 CPU); 3yr SnS Required
SLES and SAP
SLES-SAP-2S2V=-D1S= SLES for SAP Apps (1-2 CPU, 1-2 VM); Priority 1-Yr SnS
SLES-SAP-2S2V-D3S= SLES for SAP Apps (1-2 CPU, 1-2 VM); Priority 3-Yr SnS
SLES-SAP-2S2V-D5S= SLES for SAP Apps (1-2 CPU, 1-2 VM); Priority 5-Yr SnS
SLES-SAP-2S2V-D1A= SLES for SAP Apps w/ HA (1-2 CPU, 1-2 VM); 1-Yr Support Reqd
SLES-SAP-2S2V-D3A= SLES for SAP Apps w/ HA (1-2 CPU, 1-2 VM); 3-Yr Support Reqd
SLES-SAP-2S2V-D5A= SLES for SAP Apps w/ HA (1-2 CPU, 1-2 VM); 5-Yr Support Reqd
Notes:
1. This part is included with the purchase of option or spare CPU or CPU processor kits.
2. Available post first customer ship (FCS).

Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model) 80
TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS
Dimensions and Weight

Table 39 UCS C220 M7 Dimensions and Weight

Parameter Value

Height 1.70 in. (4.3 cm)

Width (including slam latches) 16.9 in.(42.9 cm)

Depth 30 in. (76.2 cm)

Weight

Weight with following options and no rail kit:


1*HDD, 1*CPU(with Heat Sink), 1*DIMM, 1*1600W PSU, mLOM card, 3HH rear wall, 15.05 kgs = 33.18 lbs
3HH riser cage1, 3HH riser cage2, 3HH riser cage3, Raid tray, BBU module (with (3HH SKU)
holder)

Weight with following options and no rail kit:


15.1 kgs = 33.29 lbs
1*HDD, 1*CPU(with Heat Sink), 1*DIMM, 1*1600W PSU, mLOM card, 2FH rear wall, (2FH SKU)
2FH riser cage1, 2FH riser cage2, Raid tray, BBU module (with holder)

Weight with following options and including rail kit:


1*HDD, 1*CPU(with Heat Sink), 1*DIMM, 1*1600W PSU, mLOM card, 3HH rear wall, 18.8 kgs = 41.45 lbs
3HH riser cage1, 3HH riser cage2, 3HH riser cage3, Raid tray, BBU module (with (3HH SKU)
holder)

Weight with following options and including rail kit:


18.85 kgs = 41.56 lbs
1*HDD, 1*CPU(with Heat Sink), 1*DIMM, 1*1600W PSU, mLOM card, 2FH rear wall, (2FH SKU)
2FH riser cage1, 2FH riser cage2, Raid tray, BBU module (with holder),

Weight with following options and no rail kit:


10*HDDs, 2*CPUs(with Heat Sink), 32*DIMMs, 2*1600W PSUs, mLOM card, 3HH rear 19.73 kgs = 43.5 lbs
wall, 3HH riser cage1, 3HH riser cage2, 3HH riser cage3, Raid tray, BBU module (3HH SKU)
(with holder)

Weight with following options and no rail kit:


19.78 kgs = 43.61 lbs
10*HDDs, 2*CPUs(with Heat Sink), 32*DIMMs, 2*1600W PSUs, mLOM card, 2FH rear (2FH SKU)
wall, 2FH riser cage1, 2FH ris-er cage2, Raid tray, BBU module (with holder)

Weight with following options and including rail kit:


10*HDDs, 2*CPUs(with Heat Sink), 32*DIMMs, 2*1600W PSUs, mLOM card, 3HH rear 23.49 kgs = 51.79 lbs
wall, 3HH riser cage1, 3HH riser cage2, 3HH riser cage3, Raid tray, BBU module (3HH SKU)
(with holder)

Weight with following options and including rail kit:


23.54 kgs = 51.9 lbs
10*HDDs, 2*CPUs(with Heat Sink), 32*DIMMs, 2*1600W PSUs, mLOM card, 2FH rear (2FH SKU)
wall, 2FH riser cage1, 2FH riser cage2, Raid tray, BBU module (with holder)

81 Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model)
TECHNICAL SPECIFICATIONS

Power Specifications
The server is available with the following types of power supplies:

■ 770 W (AC) power supply (see Table 40)


■ 1050W DC power supply (see Table 41)
■ 1200 W (AC) power supply (see Table 42)
■ 1600 W (AC) power supply (see Table 43)
■ 2300 W (AC) power supply (see Table 44)

Table 40 UCS C220 M7 770 W (AC) Power Supply Specifications

Parameter Specification
Input Connector IEC320 C14
Input Voltage Range (Vrms) 100 to 240
Maximum Allowable Input Voltage Range (Vrms) 90 to 264
Frequency Range (Hz) 50 to 60
Maximum Allowable Frequency Range (Hz) 47 to 63
Maximum Rated Output (W) 770
Maximum Rated Standby Output (W) 36
Nominal Input Voltage (Vrms) 100 120 208 230
Nominal Input Current (Arms) 8.8 7.4 4.2 3.8
Maximum Input at Nominal Input Voltage (W) 855 855 855 846
Maximum Input at Nominal Input Voltage (VA) 882 882 882 872
Minimum Rated Efficiency (%)1 90 90 90 91
Minimum Rated Power Factor1 0.97 0.97 0.97 0.97
Maximum Inrush Current (A peak) 15
Maximum Inrush Current (ms) 0.2
Minimum Ride-Through Time (ms)2 12

Notes:
1. This is the minimum rating required to achieve 80 PLUS Platinum certification, see test reports published at
http://www.80plus.org/ for certified values
2. Time output voltage remains within regulation limits at 100% load, during input voltage dropout

Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model) 82
TECHNICAL SPECIFICATIONS

Table 41 UCS C220 M7 SFF Power Specifications (1050 W V2 DC power supply)

Parameter Specification
Input Connector Molex 42820
Input Voltage Range (V rms) -48
Maximum Allowable Input Voltage Range (V rms) -40 to -72
Frequency Range (Hz) NA
Maximum Allowable Frequency Range (Hz) NA
Maximum Rated Output (W) 1050
Maximum Rated Standby Output (W) 36
Nominal Input Voltage (V rms) -48
Nominal Input Current (A rms) 24
Maximum Input at Nominal Input Voltage (W) 1154
Maximum Input at Nominal Input Voltage (VA) 1154
Minimum Rated Efficiency (%)1 91
Minimum Rated Power Factor1 NA
Maximum Inrush Current (A peak) 15
Maximum Inrush Current (ms) 0.2
Minimum Ride-Through Time (ms)2 5

Notes:
1. This is the minimum rating required to achieve 80 PLUS Platinum certification, see test reports published at
http://www.80plus.org/ for certified values
2. Time output voltage remains within regulation limits at 100% load, during input voltage dropout

83 Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model)
TECHNICAL SPECIFICATIONS

Table 42 UCS C220 M7 1200 W (AC) Power Supply Specifications

Parameter Specification
Input Connector IEC320 C14
Input Voltage Range (Vrms) 100 to 240
Maximum Allowable Input Voltage Range (Vrms) 90 to 264
Frequency Range (Hz) 50 to 60
Maximum Allowable Frequency Range (Hz) 47 to 63
Maximum Rated Output (W)1 1100 1200
Maximum Rated Standby Output (W) 48
Nominal Input Voltage (Vrms) 100 120 208 230
Nominal Input Current (Arms) 12.97 10.62 6.47 5.84
Maximum Input at Nominal Input Voltage (W) 1300 1264 1343 1340
Maximum Input at Nominal Input Voltage (VA) 1300 1266 1345 1342
Minimum Rated Efficiency (%)2 90 90 91 91
Minimum Rated Power Factor2 0.97 0.97 0.97 0.97
Maximum Inrush Current (A peak) 20
Maximum Inrush Current (ms) 0.2
Minimum Ride-Through Time (ms)3 12

Notes:
1. Maximum rated output is limited to 1100W when operating at low-line input voltage (100-127V)
2. This is the minimum rating required to achieve 80 PLUS Titanium certification, see test reports published at
http://www.80plus.org/ for certified values
3. Time output voltage remains within regulation limits at 100% load, during input voltage dropout

Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model) 84
TECHNICAL SPECIFICATIONS

Table 43 UCS C220 M7 1600 W (AC) Power Supply Specifications

Parameter Specification
Input Connector IEC320 C14
Input Voltage Range (V rms) 200 to 240
Maximum Allowable Input Voltage Range (V rms) 180 to 264
Frequency Range (Hz) 50 to 60
Maximum Allowable Frequency Range (Hz) 47 to 63
Maximum Rated Output (W) 1600
Maximum Rated Standby Output (W) 36
Nominal Input Voltage (V rms) 100 120 208 230
Nominal Input Current (A rms) NA NA 8.8 7.9
Maximum Input at Nominal Input Voltage (W) NA NA 1778 1758
Maximum Input at Nominal Input Voltage (VA) NA NA 1833 1813
Minimum Rated Efficiency (%)1 NA NA 90 91
Minimum Rated Power Factor2 NA NA 0.97 0.97
Maximum Inrush Current (A peak) 30
Maximum Inrush Current (ms) 0.2
Minimum Ride-Through Time (ms)2 12

Notes:
1. This is the minimum rating required to achieve 80 PLUS Platinum certification, see test reports published at
http://www.80plus.org/ for certified values
2. Time output voltage remains within regulation limits at 100% load, during input voltage dropout

85 Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model)
TECHNICAL SPECIFICATIONS

Table 44 UCS C220 M7 2300 W (AC) Power Supply Specifications

Parameter Specification
Input Connector IEC320 C20
Input Voltage Range (Vrms) 100 to 240
Maximum Allowable Input Voltage Range (Vrms) 90 to 264
Frequency Range (Hz) 50 to 60
Maximum Allowable Frequency Range (Hz) 47 to 63
Maximum Rated Output (W)1 2300
Maximum Rated Standby Output (W) 36
Nominal Input Voltage (Vrms) 100 120 208 230
Nominal Input Current (Arms) 13 11 12 10.8
Maximum Input at Nominal Input Voltage (W) 1338 1330 2490 2480
Maximum Input at Nominal Input Voltage (VA) 1351 1343 2515 2505
Minimum Rated Efficiency (%)2 92 92 93 93
Minimum Rated Power Factor2 0.99 0.99 0.97 0.97
Maximum Inrush Current (A peak) 30
Maximum Inrush Current (ms) 0.2
Minimum Ride-Through Time (ms)3 12

Notes:
1. Maximum rated output is limited to 1200W when operating at low-line input voltage (100-127V)
2. This is the minimum rating required to achieve 80 PLUS Titanium certification, see test reports published at
http://www.80plus.org/ for certified values
3. Time output voltage remains within regulation limits at 100% load, during input voltage dropout

NOTE: For configuration-specific power specifications, use the Cisco UCS Power
Calculator at this URL: http://ucspowercalc.cisco.com

Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model) 86
TECHNICAL SPECIFICATIONS

Environmental Specifications
The environmental specifications for Cisco UCS C220 M7 SFF server are listed in Table 45.

Table 45 UCS C220 M7 Environmental Specifications

Parameter Minimum
Operating Temperature 5°C to 35°C (supports ASHRAE Class A4 and/or Class A3 and/or
Class A2)
ASHRAE Class A3 will be generic test profile unless otherwise
specified by product engineering.
System shall continue to operate with a single fan failure (one
failed impeller in dual impeller housings) across the ASHRAE
recommended operating range of 18 °C to 27 °C. While
undesired, increased power consumption and/or acoustic noise
is permitted during a fan fail event.
Non-Operating Temperature Dry bulb temperature of -40°C to 65°C (-40°F to 149°F)
Operating Relative Humidity 8% to 90% relative humidity, non-condensing, with maximum wet
bulb 28°C (82.4°F) within operational temperature range of 5°C
to 50°C (41°F to 122°F)
Non-Operating Relative Humidity 5% to 93% relative humidity, non-condensing, with a maximum
wet bulb temperature of 28°C across the 20°C to 40°C dry bulb
range.
Maximum Operating Duration Unlimited
Operating Altitude A maximum elevation of 3050 meters (10,006 ft)
Non-Operating Altitude An elevation of 0 to 12,000 meters (39,370 ft)
Sound Power level, Measure 1RU: 5.5B
A-weighted per ISO7779 LWAd (Bels) 2RU: 5.8B
Operation at 23°C (73°F)
Racked product: 6.8B
Sound Pressure level, Measure 1RU: 40dB
A-weighted per ISO7779 LpAm (dBA)
2RU: 43dB
Operation at 23°C (73°F)
Racked product: 55dB

87 Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model)
TECHNICAL SPECIFICATIONS

Compliance Requirements
The regulatory compliance requirements for C-Series servers are listed in Table 46.

Table 46 UCS C-Series Regulatory Compliance Requirements

Parameter Description

Regulatory Compliance Products should comply with CE Markings per directives


2014/30/EU and 2014/35/EU

Safety UL 60950-1 / 62368-1


CAN/CSA-C22.2 No. 60950-1, CAN/CSA-C22.2 No. 62368-1
EN 60950-1 / EN 62368-1
IEC 60950-1 / IEC 62368-1
AS/NZS 60950-1/62368.1
GB4943

EMC - Emissions 47CFR Part 15 (CFR 47) Class A 


AS/NZS CISPR32 Class A 
CISPR32 Class A
EN55032 Class A 
ICES003 Class A 
VCCI Class A 
EN61000-3-2
EN61000-3-3
KN32 Class A 
CNS13438 Class A

EMC - Immunity EN55024


CISPR24
EN300386
KN35

Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model) 88
DISCONTINUED EOL PRODUCTS

DISCONTINUED EOL PRODUCTS


Below is the list of parts were previously available for this product and are no longer sold. Please refer to
the EOL Bulletin Links via table below to determine if still supported.

Table 47 EOS
Product ID Description EOL/EOS link
Drives
UCS-M2-240GB-D 240GB M.2 SATA Micron G1 SSD https://www.cisco.com/c/en/us/products/collate
ral/servers-unified-computing/ucs-c-series-rack-se
rvers/unified-computing-accessories-eol.html
UCS-M2-960GB-D 960GB M.2 SATA Micron G1 SSD https://www.cisco.com/c/en/us/products/collate
ral/servers-unified-computing/ucs-c-series-rack-se
rvers/unified-computing-accessories-eol.html
UCS-SD240GM1XEV-D 240GB 2.5in Enter Value 6G SATA https://www.cisco.com/c/en/us/products/collate
Micron G1 SSD ral/servers-unified-computing/ucs-c-series-rack-se
rvers/unified-computing-accessories-eol.html
UCS-SD76TM1X-EV-D 7.6TB 2.5in Enter Value 6G SATA https://www.cisco.com/c/en/us/products/collate
Micron G1 SSD ral/servers-unified-computing/ucs-c-series-rack-se
rvers/unified-computing-accessories-eol.html
UCS-SD480GM1XEV-D 480 GB 2.5in Enter Value 6G SATA https://www.cisco.com/c/en/us/products/collate
Micron G1 SSD ral/servers-unified-computing/ucs-c-series-rack-se
rvers/unified-computing-accessories-eol.html
UCSSD76TBEM2NK9-D 7.6TB 2.5in Enter Value 6G SATA https://www.cisco.com/c/en/us/products/collate
Micron G1 SSD (SED) ral/servers-unified-computing/ucs-c-series-rack-se
rvers/unified-computing-accessories-eol.html
UCSSD960GBM2NK9-D 960GB 2.5in Enter Value 6G SATA https://www.cisco.com/c/en/us/products/collate
Micron G1 SSD (SED) ral/servers-unified-computing/ucs-c-series-rack-se
rvers/unified-computing-accessories-eol.html
UCS-SD16TM1X-EV-D 1.6TB 2.5in Enter Value 6G SATA https://www.cisco.com/c/en/us/products/collate
Micron G1 SSD ral/servers-unified-computing/ucs-c-series-rack-se
rvers/unified-computing-accessories-eol.html
UCS-SD38TM1X-EV-D 3.8TB 2.5in Enter Value 6G SATA https://www.cisco.com/c/en/us/products/collate
Micron G1 SSD ral/servers-unified-computing/ucs-c-series-rack-se
rvers/unified-computing-accessories-eol.html

89 Cisco UCS C220 M7 Rack Server (Small Form Factor Disk Drive Model)

You might also like