This is to attest that

RICI COMPANY LTD.


7067, SALMAN AL-FARISI, AL-KHALIDIYA, AL-JANUBIYAH, UNIT NO. 16, EASTERN PROVINCE
AD-DAMMAM 32225, KINGDOM OF SAUDI ARABIA

Calibration Laboratory CL-151

has met the requirements of AC204, IAS Accreditation Criteria for Calibration Laboratories, and has demonstrated
compliance with ISO/IEC Standard 17025:2017, General requirements for the competence of testing and calibration
laboratories. This organization is accredited to provide the services specified in the scope of accreditation.
Effective Date September 15, 2023
Expiration Date February 1, 2025

President
RICI COMPANY LTD.
www.ricionline.com

Contact Name Usama Bin Waseem Contact Phone + 966-138590481, ext:


5611
Accredited to ISO/IEC 17025:2017 Effective Date September 15, 2023

CALIBRATION AND MEASUREMENT CAPABILITY (CMC)*


MEASURED RANGE UNCERTAINTY1,2 CALIBRATION METHOD OR
QUANTITY or DEVICE (±) PROCEDURE, STANDARD
TYPE CALIBRATED EQUIPMENT (OPTIONAL)
Dimensional
Calipers

Dial and Vernier 0 mm to 300 mm 7.5 µm Gage blocks

Digital 0 mm to 300 mm 7.5 µm Gage Blocks with accessories

Dial / Digital / Vernier 300 mm to 1000 mm 16 µm LABC-001


1000 mm to 2000 mm 30 µm
Plunger Type Indicators

Dial 0 mm to 25 mm 6 µm Dial Gage Calibrator


LABC-002
Digital 0 mm to 25 mm 2 µm
Outside Micrometers

Plain Anvil 0 mm to 25 mm 6 µm Gage blocks

Digital 0 mm to 25 mm 0.2 µm Gage Blocks with accessories

Plain Anvil / Digital 25 mm to 150 mm 2.2 µm LABC-003


150 mm to 1000 mm 14.5 µm
External / Outside ULM 600
Micrometer LABC-159

Anvil 0 mm to 25 mm 6.0 µm
Digital 0 mm to 25 mm 1.1 µm
Plain Anvil / Digital 25 mm to 150 mm 2.6 µm

Inside Micrometer 0 mm to 600 mm 10 µm ULM 600


LABC-160

* If information in this CMC is presented in non-SI units, the conversion factors stated in NIST Special Publication
811 “Guide for the Use of the International System of Units (SI)” apply.

CL-151 Effective Date September 15, 2023


RICI Company Limited Page 2 of 16
IAS/CL/100-3
MEASURED RANGE UNCERTAINTY1,2 CALIBRATION METHOD OR
QUANTITY or DEVICE (±) PROCEDURE, STANDARD
TYPE CALIBRATED EQUIPMENT (OPTIONAL)
Coating Thickness Gauge 0 µm to 1600 µm 0.5 µm Coating Thickness Standards
LABC-014
Height Gauges 0 mm to 300 mm 6.2 µm Gage Blocks
300 mm to 1000 mm 15 µm
1000 mm to 2000 mm 30 µm LABC-093
Depth Gauges 0 mm to 300mm 6.2 µm Gage Blocks with accessories
LABC-076
Snap Gauges 0 mm to 500 mm 14 µm Gage Blocks with accessories
LABC-083
Measuring Tapes 0 mm to 50000 mm 0.57 mm Measuring Tape Calibrator,
Reference Measuring Tape
LABC-045
Rulers / Measuring Scales 0 mm to 1000 mm 0.06 mm Measuring Tape Calibrator,
Reference Measuring Tape
LABC-045
Thickness Gauge 0 µm to 1000 µm 0.57 µm Gage Block
0 mm to 10 mm 0.59 µm LABC-034
0 mm to 100 mm 0.061 mm
Sieves Reference Calibrator, Digital
Fine Up to 850 µm 0.023 µm Caliper
Coarse 1 mm to 200 mm 0.041 mm
LABC-049

Bevel / Digital Protractors 0° to 90° 0.030° Angle Gage Block Set


LABC-025
Angle Gauges 0° to 90° 0.030° Angle Gage Block Set
LABC-025
Profile Projector/ 0 mm to 200 mm 0.63 µm Stage Micrometers/ Glass
Measuring Microscopes Scale, Gage Blocks
LABC-132
Bore Gauges 0 mm to 25 mm 1.9 µm Dial Gauge Calibrator, Gauge
Blocks with Accessories
LABC-078
Dial Gauge Calibrator 0.5 mm to 25 mm 0.38 µm Gauge Blocks with
Accessories
LABC-099

Inside Micrometer 25 mm to 150 mm 2.3 µm Inside Micrometer Checker,


150 mm to 1000 mm 15 µm Gauge Blocks with
Accessories
LABC-038

Slip Gauges 0 mm to 25 mm 0.40 µm Slip Gauge Comparator


25 mm to 50 mm 0.61 µm LABC-166
50 mm to 100 mm 1.0 µm

CL-151 Effective Date September 15, 2023


RICI Company Limited Page 3 of 16
IAS/CL/100-3
MEASURED RANGE UNCERTAINTY1,2 CALIBRATION METHOD OR
QUANTITY or DEVICE (±) PROCEDURE, STANDARD
TYPE CALIBRATED EQUIPMENT (OPTIONAL)
Plain Snap / Gap Gage 0 mm to 8 mm 2.0 µm ULM-600
(GO / NO-GO) 8 mm to 200 mm 3.1 µm LABC-146
200 mm to 400 mm 5.7 µm
Plain Plug Gauge 0 mm to 25 mm 0.38 µm ULM 600
(GO/NO-GO) 25 mm to 50 mm 0.96 µm LABC-147
50 mm to 100 mm 1.9 µm
100 mm to 300 mm 6.0 µm
300 mm to 600 mm 12 µm
Ring Gauge (GO/NO-GO) 0 mm to 8 mm 2.0 µm ULM 600
8 mm to 200 mm 3.1 µm LABC-148
200 mm to 600 mm 8.3 µm
Thread Plug Gauge 0 mm to 600 mm ULM 600
(GO/NO-GO) Effective / Pitch Diameter 8.2 µm LABC-149
Major Diameter 8.1 µm
Thread Ring Gauge Effective / Pitch Diameter ULM 600
(GO/NO-GO) 0 mm to 6 mm 0.16 µm LABC-150
Major Diameter
0 mm to 25 mm 0.37 µm
25 mm to 50 mm 0.70 µm
50 mm to 100 mm 1.4 µm
100 mm to 300 mm 4.5 µm
300 mm to 400 mm 6.2 µm
Gauge Blocks 0 mm to 500 mm 6.6 µm ULM 600
LABC-166
Length Bar 0 mm to 25 mm 0.14 µm ULM 600
25 mm to 50 mm 0.19 µm LABC-152
50 mm to 100 mm 0.24 µm
100 mm to 300 mm 1.8 µm
300 mm to 500 mm 3.0 µm
Plain Ring Gauge 0 mm to 8 mm 2.0 µm ULM 600
8 mm to 200 mm 3.1 µm LABC-153
200 mm to 600 mm 8.1 µm
Setting Cylindrical Master 0 mm to 25 mm 0.49 µm ULM 600
25 mm to 50 mm 0.97 µm LABC-154
50 mm to 100 mm 1.9 µm
100 mm to 300 mm 6.0 µm
300 mm to 400 mm 8.1 µm
Measuring Pins 0 mm to 20 mm 0.29 µm ULM 600
LABC-155
Plunger Type Dial Gauge 0 mm to 100 mm 5.9 µm ULM 600
LABC-156

Lever Type Dial Gauge 0 mm to 1 mm 5.7 µm ULM 600


LABC-157
Bore Gauge 0 mm to 100 mm 1.5 µm ULM 600

CL-151 Effective Date September 15, 2023


RICI Company Limited Page 4 of 16
IAS/CL/100-3
MEASURED RANGE UNCERTAINTY1,2 CALIBRATION METHOD OR
QUANTITY or DEVICE (±) PROCEDURE, STANDARD
TYPE CALIBRATED EQUIPMENT (OPTIONAL)
LABC-158
Plain Taper Plug Gauge Diameter 0 mm to 600 mm 8.1 µm ULM 600
LABC-162

Taper Ring Gauge 0 mm to 8 mm 2.0 µm ULM 600


8 mm to 200 mm 3.1 µm LABC-163
200 mm to 400 mm 5.8 µm
Taper Thread Plug Gauge Effective / Pitch Diameter ULM 600
0 mm to 600 mm 12 µm LABC-164

Major Diameter
0 mm to 600 mm 8.1 µm
Taper Thread Ring Gauge Effective Diameter ULM 600
0 mm to 8 mm 2.0 µm LABC-161
8 mm to 100 mm 2.0 µm
Jigs and Fixtures Length 0 mm to 25 mm 0.69 µm ULM 600 / Slip Gauge Blocks
Measurement 25 mm to 50 mm 0.92 µm / Long Slip Gauges
50 mm to 100 mm 1.6 µm
100 mm to 200 mm 3.9 µm LABC-171
200 mm to 300 mm 5.7 µm
300 mm to 400 mm 7.6 µm
400 mm to 500 mm 9.4 µm
500 mm to 1000 mm 20 µm
1000 mm to 2000 mm 41 µm
Mechanical
Force-Compression 0.0025 kN to 3000 kN 0.2 % Load Cells
LABC-007
Force-Tension Up to 50 kN 0.03 kN Tensile Load cell
LABC-168
Proving Rings 0 kN to 50 kN 0.05 kN Reference Load Cell with
Indicator
LABC-066
Balances 0 g to 210 g 0.33 mg Class E1, F1 Weights
201 g to 2.1 kg 6.7 mg LABC-006
2.1 kg to 8 kg 11 mg
8 kg to 30 kg 77 mg
30 kg to 100 kg 94 g
100 kg to 500 kg 0.06 kg

Pressure Gauges -1 bar to 10 bar 0.06 bar Dead Weight Tester,


0 bar to 60 bar 0.07 bar Test Pump with Reference
0 bar to 100 bar 0.12 bar Pressure Gauge
0 bar to 600 bar 0.22 bar LABC-004
0 bar to 1400 bar 0.28 bar
0 bar to 2800 bar 1.6 bar

CL-151 Effective Date September 15, 2023


RICI Company Limited Page 5 of 16
IAS/CL/100-3
MEASURED RANGE UNCERTAINTY1,2 CALIBRATION METHOD OR
QUANTITY or DEVICE (±) PROCEDURE, STANDARD
TYPE CALIBRATED EQUIPMENT (OPTIONAL)
Pressure Transmitter -1 bar to 10 bar 0.06 bar Dead Weight Tester, Test
0 bar to 60 bar 0.07 bar Pump with Reference
0 bar to 100 bar 0.12 bar Pressure Gauge, Process
0 bar to 600 bar 0.22 bar Calibrator, HART/Fieldbus
0 bar to 1400 bar 0.28 bar Communicator, Reference
0 bar to 2800 bar 1.6 bar Multimeter
LABC-103 (a&b)
Pressure Chart Recorder -1 bar to 10 bar 0.06 bar Dead Weight Tester, Test
0 bar to 60 bar 0.07 bar Pump with Reference
0 bar to 100 bar 0.12 bar Pressure Gauge
0 bar to 600 bar 0.22 bar LABC-079
0 bar to 1400 bar 0.28 bar
0 bar to 2800 bar 1.6 bar
Durometer Rubber Hardness Tester
(Shore Scale A) 0 shore to 100 shore 1.3 shore Calibrator with Standard
(Shore Scale D) 0 shore to 100 shore 1.3 shore Weights
LABC-059
Hardness Testing HV 190 2.7 HV Standard Test Blocks
Machines (Vicker) HV 208 2.9 HV LABC-024
HV 524 6.5 HV
HV 720 5.8 HV
HV 813 5.2 HV
Hardness Testing HRA 0.82 HRA Standard Test Blocks
Machines (Rockwell, HRB 0.83 HRB LABC-024
Brinell) HRC 0.84 HRC
HR15N 0.3 HR
HR30N 0.3 HR
HR45N 0.37 HR
HB3000 4.2 HB
HB500 1.5 HB
Vacuum Gages 0 inHg to 30 inHg 0.008 inHg Test pump and master gage
LABC-005
Safety Relief Valve 0 psi to 860 psi 6.1 psi Test Pump and Standard
0 psi to 10,000 psi 6.1 psi Pressure gages
LABC 017
Torque Wrench 0 N·m to 50 N·m 0.14 N·m Torque Wrench Calibrator &
50 N·m to 250 N·m 0.71 N·m Transducers
250 N·m to 500 N·m 1.4 N·m LABC-022
500 N·m to 1000 N·m 3.1 N·m
Sound Level Meter 94 dB to 114 dB 0.31 dB Acoustic Calibrator
@ 16 kHz LABC-020
Vibration Meter Up to 20 m/s2 0.82 m/s2 Vibration Calibrator
LABC-021
Asphalt Batch Plant 1000 kg 0.06 kg Class M1 Standard Weights
LABC-116

CL-151 Effective Date September 15, 2023


RICI Company Limited Page 6 of 16
IAS/CL/100-3
MEASURED RANGE UNCERTAINTY1,2 CALIBRATION METHOD OR
QUANTITY or DEVICE (±) PROCEDURE, STANDARD
TYPE CALIBRATED EQUIPMENT (OPTIONAL)
Concrete Batch Plant 1000 kg 0.06 kg Class M1 Standard Weights
LABC-116
Volume Up to 1000 L 0.058 L Reference Flow Meter
LABC-128
Pipettes/ Micropipettes Up to 100 μL 0.58 μL Mass Comparators,
(Gravimetric Method) 100 μL to 300 μL 0.71 μL Reference Thermometer
300 μL to 1 mL 0.71 μL LABC-123
1 mL to 2 mL 0.71 μL
2 mL to 5 mL 0.71 μL
5 mL to 10 mL 0.71 μL
10 mL to 25 mL 0.79 μL
25 mL to 50 mL 1.1 μL
50 mL to 100 mL 2.7 μL
Burettes Up to 500 μL 0.71 μL Mass Comparators,
500 μL to 1 mL 0.71 μL Reference Thermometer
1 mL to 2 mL 0.71 μL LABC-124
2 mL to 5 mL 0.71 μL
5 mL to 10 mL 0.71 μL
10 mL to 25 mL 0.79 μL
25 mL to 50 mL 1.1 μL
50 mL to 100 mL 2.7 μL

Cylinders/ Beakers 2 mL to 5 mL 0.71 μL Mass Comparators,


5 mL to 10 mL 0.71 μL Reference Thermometer
10 mL to 25 mL 0.79 μL LABC-125
25 mL to 50 mL 1.1 μL
50 mL to 100 mL 2.7 μL
500 mL to 1000 mL 25 μL
1000 mL to 2000 mL 40 μL
2000 mL to 10000 mL 0.25 mL

Flasks 2 mL to 5 mL 0.71 μL Mass Comparators,


5 mL to 10 mL 0.71 μL Reference Thermometer
10 mL to 25 mL 0.79 μL LABC-126
25 mL to 50 mL 1.1 μL
50 mL to 100 mL 2.7 μL
500 mL to 1000 mL 25.2 μL

Pycnometers Up to 1 mL 0.71 μL Mass Comparators,


1 mL to 2 mL 0.72 μL Reference Thermometer
2 mL to 5 mL 0.72 μL LABC-127
5 mL to 10 mL 0.76 μL
10 mL to 25 mL 1.1 μL
25 mL to 50 mL 1.4 μL
50 mL to 100 mL 2.7 μL

CL-151 Effective Date September 15, 2023


RICI Company Limited Page 7 of 16
IAS/CL/100-3
MEASURED RANGE UNCERTAINTY1,2 CALIBRATION METHOD OR
QUANTITY or DEVICE (±) PROCEDURE, STANDARD
TYPE CALIBRATED EQUIPMENT (OPTIONAL)
Pressure Calibrators / 0 bar to 10 bar 0.06 bar Dead weight tester, Test
Pumps 10 bar to 60 bar 0.07 bar pump with reference pressure
60 bar to 100 bar 0.12 bar gauge
100 bar to 600 bar 0.22 bar LABC-130
600 bar to 1400 bar 0.28 bar
1400 bar to 2800 bar 1.6 bar
Pressure Generate3 0 bar to 500 bar 0.64 bar Ultra High Pressure
500 bar to 825 bar 2.6 bar Pneumatic Pump / Reference
825 bar to 2800 bar 6.3 bar Digital Pressure Gauge
LABC-169
Pressure Measure4 0 bar to 500 bar 0.64 bar Reference Digital Pressure
500 bar to 825 bar 2.6 bar Gauge
825 bar to 2800 bar 6.3 bar LABC-170
Magnetometer/ Gauss 0 Gs to 50 Gs 1.3 Gs Gauss Meter Calibrator
Meters LABC-053
Mass (Standard Weights) 20 kg 41 mg Mass Comparators,
All Classes 10 kg 14 mg Class E1 Standard Weights
E1, E2, F1, F2, M1, M2 5 kg 7.1 mg LABC-088
2 kg 2.9 mg
1 kg 1.4 mg

500 g 0.72 mg
200 g 0.29 mg
100 g 0.14 mg
50 g 0.072 mg
20 g 0.031 mg
10 g 0.017 mg
5g 0.10 mg
2g 0.048 mg
1g 0.002 mg

500 mg 2.5 μg
200 mg 1.6 μg
100 mg 1.5 μg
50 mg 1.2 μg
20 mg 1.1 μg
10 mg 0.9 μg
5 mg 0.7 μg
2 mg 0.7 μg
1 mg 0.7 μg
Hydrometers 0.600 g/mL to 1.050 g/mL 0.0029 g/mL Reference Solutions
0.600 g/mL to 1.050 g/mL 0.00031 g/mL LABC-064
Anemometers/ Air Meters 25 ft/min to 9000 ft/min 7 ft/min Reference Air Meter, Wind
(Air Velocity) Tunnel
LABC-069
Densitometers 0 D to 14 D 0.021 D Reference Density Film
LABC-068

CL-151 Effective Date September 15, 2023


RICI Company Limited Page 8 of 16
IAS/CL/100-3
MEASURED RANGE UNCERTAINTY1,2 CALIBRATION METHOD OR
QUANTITY or DEVICE (±) PROCEDURE, STANDARD
TYPE CALIBRATED EQUIPMENT (OPTIONAL)
Electromagnetic Yoke Lifting Power 4.5 kg (AC) Standard Dead Weight
10 lbf·ft 0.0054 lbf·ft LABC 101
Nuclear Density Gauges Density: Nuclear Validator
1120 kg/m3 to 2723 kg/m3 0.95 kg/m3 Note: Models that will be
calibrated: VPN
Troxler (3411, 3430, 3440,
3440+) Humboldt
LABC 019
Hydraulic Torque Wrench 0 N·m to 1000 N·m 15 N·m Hydraulic Torque Assembly
1000 N·m to 2000 N·m 23 N·m LABC-087
2000 N·m to 4000 N·m 54 N·m
4000 N·m to 8000 N·m 140 N·m
8000 N·m to 30000 N·m 960 N·m
30000 N·m to 50000 N·m 2000 N·m
Thermal
Ovens 0 °C to 250 °C 0.6 °C RTDs, Temperature Calibrator
LABC-008
0 °C to 400 °C 0.21 ˚C RTDs,
Temperature Calibrator
LABC-008
Thermometers
Dial -10 °C to 200 °C 0.30 °C RTD, Dry Block, Oil Bath

Digital -40 °C to 200 °C 0.21 °C RTD, Dry Block, Oil Bath

Dial/Digital -40 °C to 140 °C 0.06 °C RTD, Dry Block, Oil Bath,


140 °C to 650 °C 0.13 °C Temperature Calibrator
650 °C to 1200 ºC 0.82 °C LABC-011 (Digital)
LABC-012 (Dial)
RTD -40 °C to 140 °C 0.06 °C RTD, Dry Block, Oil Bath
LABC-013
140 °C to 650 °C 0.13 °C Universal Calibrator, Dry
Block Oil Bath, Comparison to
Standard RTD
LABC-013
650 °C to 1200 °C 0.82 °C RTD, Dry Block, Oil Bath
LABC-013
Water Baths 0 °C to 90 °C 0.2 °C RTD, Temperature Calibrator
LABC-009

Furnaces 0 °C to 1200 °C 0.8 °C Reference Thermocouple,


Temperature Calibrator
LABC-010
Autoclaves 0 °C to 150 °C 0.12 °C RTDs,
Temperature Calibrator

CL-151 Effective Date September 15, 2023


RICI Company Limited Page 9 of 16
IAS/CL/100-3
MEASURED RANGE UNCERTAINTY1,2 CALIBRATION METHOD OR
QUANTITY or DEVICE (±) PROCEDURE, STANDARD
TYPE CALIBRATED EQUIPMENT (OPTIONAL)
LABC-036
Incubators 10 °C to 100 °C 0.12 °C RTDs,
Temperature Calibrator
LABC-067
Hot Plates 0 °C to 300 °C 0.62 °C Reference Surface Probe,
Temperature Calibrator
LABC-037
Freezers/ Refrigerators -80 °C to 100 ºC 0.12 °C RTDs,
Temperature Calibrator
LABC-067
Temperature Transmitter -40 °C to 140 °C 0.06 °C RTD, Dry Block, Oil Bath,
140 °C to 650 °C 0.13 °C Process Calibrator,
650 °C to 1200 °C 0.76 °C HART/Fieldbus
Communicator,
Reference Multimeter
LABC-070 (a &b)
Temperature Recorder -40 °C to 140 °C 0.17 °C RTD,
140 °C to 650 °C 0.36 °C Dry Block,
650 °C to 1200 °C 0.76 °C Oil Bath,
Temperature Calibrator
LABC-032
Temperature – Measure4 -40 °C to 140 °C 0.035 °C RTD Sensors, Thermocouples
140 °C to 350 °C 0.024 °C LABC-067
350 °C to 650 °C 0.71 °C
650 °C to 1200 °C 0.79 °C
Infrared Thermometers -40 °C to 140 °C 0.015 °C Blackbody Sources
140 °C to 650 °C 0.14 °C LABC-027
650 °C to 1200 °C 0.76 °C
Thermo-Hygrometer Temperature: 0.11 °C Temperature Humidity
10 °C to 50 °C @ 50 % RH Chamber
LABC-080
Humidity: 2.84 %RH
10 % to 90 % RH @ 23 °C

Electrical – DC/LF
Welding Machines 0 A to 600 A 1.2 % of Setting Check Master 9000
0 V to 50 V (DC) 0.56 V LABC-016
Holiday Detector 0 kV to 40 kV 0.06 kV Fluke High Voltage Probe,
Digital Multimeter
LABC-015
DC Voltage –Generate3 0 mV to 329.9999 mV 0.4 µV Multi Product Calibrator Fluke
0.33 V to 3.299999 V 6.3 µV 5522A
3.3 V to 32.99999 V 0.12 mV LABC-018
33 V to 329.9999 V 0.97 mV
330 V to 1020.000 V 3.5 mV

CL-151 Effective Date September 15, 2023


RICI Company Limited Page 10 of 16
IAS/CL/100-3
MEASURED RANGE UNCERTAINTY1,2 CALIBRATION METHOD OR
QUANTITY or DEVICE (±) PROCEDURE, STANDARD
TYPE CALIBRATED EQUIPMENT (OPTIONAL)
DC Voltage – Measure4 0 mV to 100 mV 0.0018 mV
100 mv to 1 V 0.003 mV Precision Multimeter Fluke
1 V to 10 V 0.03 mV 8846A
10 V to 100 V 0.0014 V LABC-018
100 V to 1000 V 0.12 V
DC Current – Generate3 0 μA to 329.999 μA 5.3 nA Multi Product Calibrator Fluke
0 mA to 3.29999 mA 35 nA 5522A
0 mA to 32.9999 mA 0.92 µA LABC-018
0 mA to 329.999 mA 8.8 µA
0 A to 1.09999 A 41 µA
1.16 A to 2.99999 A 0.11 mA
0 A to 10.9999 A 1.3 mA
11 A to 20.5 A 7 mA
Clamp meter 0 to 1000 A Fluke 5500A / Coil (50 Turns)
(DC) 0.067 A LABC-018
(AC @ 60 Hz) 0.071 A
DC Current – Measure4 0 μA to 100 μA 0.012 µA Precision Multimeter Fluke
100 uA to 1 mA 0.019 µA 8846A
1 mA to 10 mA 1.3 µA LABC-018
10 mA to 100 mA 3.3 µA
100 mA to 400 mA 0.039 mA
400 mA to 1 A 0.14 mA
1 A to 3 A 1.1 mA
3A to 10 A 1.2 mA

DC Resistance – 0 kΩ to 1 kΩ 4.3 mΩ Multi Product Calibrator Fluke


Generate3 1 kΩ to 10 kΩ 55 mΩ 5522A
10 kΩ to 100 kΩ 0.46 Ω Decade Resistance Box
100 kΩ to 1 MΩ 8.8 Ω LABC-018
1 MΩ to 10 MΩ 150 Ω
10 MΩ to 100 MΩ 17 kΩ
100 MΩ to 1 GΩ 7.2 MΩ

DC Resistance – 0 Ω to 100 Ω 2.3 mΩ Precision Multimeter Fluke


Measure4 100 Ω to 1 kΩ 0.015 Ω 8846A
1 kΩ to 10 kΩ 0.16 Ω LABC-018
10 kΩ to 100 kΩ 1.5 Ω
100 kΩ to 1 MΩ 0.14 kΩ
1 MΩ to 10 MΩ 0.18 kΩ
10 MΩ to 100 MΩ 0.044 MΩ
100 MΩ to 1 GΩ 3.3 MΩ

AC Voltage – Generate3 1 mV to 32.999 mV Multi Product Calibrator Fluke


(10 Hz to 450 kHz) 4.5 µV 5522A
LABC-018
33 mV to 329.999 mV
(10 Hz to 500 kHz) 14 µV

CL-151 Effective Date September 15, 2023


RICI Company Limited Page 11 of 16
IAS/CL/100-3
MEASURED RANGE UNCERTAINTY1,2 CALIBRATION METHOD OR
QUANTITY or DEVICE (±) PROCEDURE, STANDARD
TYPE CALIBRATED EQUIPMENT (OPTIONAL)
Multi Product Calibrator Fluke
0.33 V to 3.29999 V 5522A
(10 Hz to 450 kHz) 34 µV LABC-018

3.3 V to 32.9999 V
(10 Hz to 90 kHz) 4.4 mv

33 V to 329.999 V
(45 Hz to 100 kHz) 16 mV

330 V to 1020 V
(45 Hz to 8 kHz) 39 mV

AC Voltage – Measure4 0 mV to 100 mV Precision Multimeter Fluke


(3 Hz to 300 kHz) 0.032 mV 8846A
LABC-018
100 mV to 1 V
(10 Hz to 300 kHz) 0.70 mV

1 V to 10 V
(10 Hz to 300 kHz) 2.8 mV

10 V to 100 V
(10 Hz to 300 kHz) 0.026 V

100 V to 1000 V
(10 Hz to 300 kHz) 0.039 V

AC Current – Generate3 29.00 μA to 329.99 μA Multi Product Calibrator Fluke


(10 Hz to 30 kHz) 29 nA 5522A
LABC-018
0.33 mA to 3.2999 mA
(10 Hz to 30 kHz) 0.26 µA

3.3 mA to 32.999 mA
(10 Hz to 30 kHz) 5 µA

33 mA to 329.99 mA
(10 Hz to 30 kHz) 47 µA

0.33 A to 1.09999 A
(10 Hz to 10 kHz) 0.38 mA

1.1 A to 10.9999 A
(10 Hz to 10 kHz) 1.8 mA

11 A to 20.5 A
(45 Hz to 5 kHz) 4.9 mA

CL-151 Effective Date September 15, 2023


RICI Company Limited Page 12 of 16
IAS/CL/100-3
MEASURED RANGE UNCERTAINTY1,2 CALIBRATION METHOD OR
QUANTITY or DEVICE (±) PROCEDURE, STANDARD
TYPE CALIBRATED EQUIPMENT (OPTIONAL)
AC Current – Measure4 0 μA to 100 μA 0.044 µA Precision Multimeter Fluke
at 3 Hz to 10 kHz 1 µA to 1 mA 0.31 µA 8846A
1 mA to 10 mA 3.1 µA LABC-018
10 mA to 100 mA 3.2 µA
100 mA to 400 mA 0.30 mA
400 mA to 1 A 0.30 mA
1 A to 3 A 4.5 mA
3 A to 10 A 4.5 mA
Electrical Simulation of Multi Product Calibrator Fluke
Thermocouples – 5522A (with TC measuring
Generate and Measure option)
LABC -18
Type B 600 ºC to 1820 ºC Generate: 0.12 ºC
Measure: 0.18 ºC

Type C 0 ºC to 2316 ºC Generate: 0.12 ºC


Measure: 0.18 ºC

Type E -250 ºC to 1000 ºC Generate: 0.097 ºC


Measure: 0.18 ºC

Type J -210 ºC to 1200 ºC Generate: 0.12 ºC


Measure: 0.18 ºC

Type K -200 ºC to 1372 ºC Generate: 0.12 ºC


Measure: 0.18 ºC

Type L -200 ºC to 900 ºC Generate: 0.097 ºC


Measure: 0.18 ºC

Type N -200 ºC to 1300 ºC Generate: 0.12 ºC


Measure: 0.18 ºC

Type R 0 ºC to 1767 ºC Generate: 0.12 ºC


Measure: 0.18 ºC

Type S 0 ºC to 1767 ºC Generate: 0.12 ºC


Measure: 0.18 ºC

Type T -250 ºC to 400 ºC Generate: 0.097 ºC


Measure: 0.18 ºC

Type U -200 ºC to 600 ºC Generate: 0.097 ºC


Measure: 0.18 ºC
Electrical Simulation of
RTD – Generate
Pt 385, 100 Ω -200 ºC to 800 ºC 0.012 ºC
Pt 385, 200 Ω -200 ºC to 630 ºC 0.012 ºC Temperature Calibrator Fluke
Pt 385, 500 Ω -200 ºC to 630 ºC 0.012 ºC 525B

CL-151 Effective Date September 15, 2023


RICI Company Limited Page 13 of 16
IAS/CL/100-3
MEASURED RANGE UNCERTAINTY1,2 CALIBRATION METHOD OR
QUANTITY or DEVICE (±) PROCEDURE, STANDARD
TYPE CALIBRATED EQUIPMENT (OPTIONAL)
Pt 385, 1000 Ω -200 ºC to 630 ºC 0.012 ºC LABC-018
Capacitance – Generate (10 Hz to 10 kHz)
3,5 Multi Product Calibrator Fluke
220.0 pF to 399.9 pF 3.9 pF 5522A
0.4 nF to 1.0999 nF 0.004 nF LABC-018

(10 Hz to 3 kHz)
1.16 nF to 3.2999 nF 0.0051 nF

(10 Hz to 1 kHz)
3.3 nF to 10.9999 nF 0.0078 nF
11 nF to 32.999 nF 0.049 nF
110 nF to 329.999 nF 0.21 nF

(10 Hz to 600 Hz)


0.33 µF to 1.09999 μF 0.75 nF

(10 Hz to 300 Hz)


1.16 μF to 3.299999 μF 0.0076 μF

(10 Hz to 150 Hz)


3.3 μF to 10.9999 μF 0.022 μF

(10 Hz to 120 Hz)


11 μF to 32.9999 μF 0.008 μF

(10 Hz to 80 Hz)
33 μF to 109.9999 μF 0.60 μF

(0 Hz to 50 Hz)
110 μF to 329.999 μF 0.22 μF

(0 Hz to 20 Hz)
0.33 mF to 1.09999 mF 0.16 μF

(0 Hz to 6 Hz)
1.16 mF to 3.2999 mF 0.0014 mF

(0 Hz to 2 Hz)
3.3 mF to 10.9999 mF 0.034 mF

(0 Hz to 0.6 Hz)
11 mF to 32.9999 mF 0.120 mF

(0 Hz to 0.2 Hz)
33 mF to 110.00 mF 0.034 mF
Capacitance – Measure4 0 nF to 1 nF 0.016 nF Precision Multimeter Fluke
1 nF to 10 nF 0.063 nF 8846A
10 nF to 100 nF 0.63nF LABC-018
100 nF to 1 μF 6.3 nF

CL-151 Effective Date September 15, 2023


RICI Company Limited Page 14 of 16
IAS/CL/100-3
MEASURED RANGE UNCERTAINTY1,2 CALIBRATION METHOD OR
QUANTITY or DEVICE (±) PROCEDURE, STANDARD
TYPE CALIBRATED EQUIPMENT (OPTIONAL)
1 μF to 10 μF 0.063 μF
10 μF to 100 μF 0.68 μF
100 μF to 1 mF 6.9 μF
1 mF to 10 mF 0.070 mF
10 mF to 100 mF 1.16 mF
Power Factor @ 60 Hz 0.009 3-Phase Power Energy Meter
LABC-144
AC Power @ 60 Hz Up to 1.8 kW 0.006 kW 3-Phase Power Energy Meter
LABC-144
AC Energy @ 60 Hz, Up to 1.8 kW*24 hour 0.006 kWh 3-Phase Power Energy Meter
300 V / 6 A LABC-144
Time and Frequency
Stop Watch and Time 2 ms to 999 ms 2.7 ms Time Interval Meter
Measuring Devices 2 s to 1 h 1.3 s LABC-167
1 h to 24 h 7.3 s
Non-Contact Tachometer 2 rpm to 99999 rpm 1.1 rpm Tachometer Calibrator
LABC-091
Centrifuge 0 rpm to 999 rpm 7.8 rpm Reference Tachometer
1000 rpm to 99999 rpm 5.9 rpm LABC-131
Chemical
pH Meters 0 pH to 14 pH 0.002 pH Reference Bμffer Solutions
LABC-074
Conductivity Meter 1413 µS/cm 0.34 % Reference Solutions
12880 µS/cm 0.11 % LABC-047
Viscosity Meter 500 CPS to 5000 CPS 1.1 % Reference Solutions
LABC-057
Spectrophotometers 190 nm to 1100 nm 0.06 nm Reference Kits
LABC-133
Dissolved Oxygen Meter Zero Calibration 1.2 % Reference Solutions
LABC-089
Multi Gas Detectors Methane: 50 %LEL, 2.0 % Standard Span Calibration
O2: 20.9 %, 2.0 % Gases
H2S: 25 ppm 2.0% LABC-023
CO: 100 ppm 2.0 %

1The uncertainty covered by the Calibration and Measurement Capability (CMC) is expressed as the expanded
uncertainty having a coverage probability of approximately 95 %. It is the smallest measurement uncertainty that a
laboratory can achieve within its scope of accreditation when performing calibrations of a best existing device. The
measurement uncertainty reported on a calibration certificate may be greater than that provided in the CMC due to the
behavior of the calibration item and other factors that may contribute to the uncertainty of a specific calibration.
2When uncertainty is stated in relative terms (such as percent, a multiplier expressed as a decimal fraction or in scientific
notation), it is in relation to instrument reading or instrument output, as appropriate, unless otherwise indicated.
3Capability is suitable for the calibration of measuring devices in the stated ranges.

CL-151 Effective Date September 15, 2023


RICI Company Limited Page 15 of 16
IAS/CL/100-3
4Capability is suitable for the calibration of devices intended to generate the indicated quantity in the stated ranges.
5Stateduncertainties are valid for the ranges of frequencies given, but the actual frequency applied by the calibrator may
be dependent on the measurement device under calibration.

Notes:
1. Gs = Gauss; 1 Gs corresponds to 10-4 T
2. CPS = Centipoise
3. D = Degree of Darkness (optical density)
4. ppm = parts per million

CL-151 Effective Date September 15, 2023


RICI Company Limited Page 16 of 16
IAS/CL/100-3

You might also like