Gate Gorakhpur
Gate Gorakhpur
Gate Gorakhpur
: 240314
Rev.: R0
Sri Gaje Singh and Sri Ankit Mittal from IOCL have approached us to prepare As-built
drawings and conduct structural stability checks for Gate 0, which has been constructed
at Gorapkhpur LPG BP.
Location LP BP GORAPKHPUR
Client IOCL
Drawing Checked By
Report By
INTRODUCTION
A. Engineers acquired measurements for the analysis from the given drawing.
Elevation
B. Connection.
C. Specifications and drawings for components have been developed using the measurements from
the existing drawing.
Dimension:-
Width:-12mtr
Height:-3mtr
Technical specification of Gate
Material MS Steel
Thickness 3mm MS sheet
Frame Rectangular hollow section
SHS (75X75X4.5)
Bottom ISMC150
Rail Rod 25mm
Bracing Support Wheel Roller
All the structural members are connected in individual members using the welding and
bolt connections.
STAAD SPACE
START JOB INFORMATION
ENGINEER DATE 07-Mar-24
END JOB INFORMATION
INPUT WIDTH 79
UNIT METER KN
JOINT COORDINATES
1 0 0 0; 3 9.5 0 0; 4 9.5 -3 0; 6 3.5 -3 0; 7 0 -0.075 0; 8 3.5 -0.075 0;
14 9.425 -0.075 0; 15 9.425 -2.925 0; 19 3.575 -2.925 0; 20 9.6 0 0;
21 9.6 -3 0; 23 19.1 0 0; 24 15.6 -3 0; 26 15.6 -0.075 0; 27 19.1 -0.075 0;
31 15.525 -2.925 0; 32 9.675 -0.075 0; 33 9.675 -2.925 0; 34 5 -3 0; 35 8 -3 0;
36 11.1 -3 0; 37 14.1 -3 0; 38 0 -3.825 0; 39 19 -3.825 0; 40 3.575 -0.075 0;
41 15.525 -0.075 0;
MEMBER INCIDENCES
7 8 6; 8 3 4; 9 1 7; 10 7 8; 19 14 15; 20 1 3; 21 6 34; 32 21 36; 36 26 27;
37 27 23; 38 24 26; 39 20 21; 43 20 23; 47 33 31; 48 32 33; 50 34 35; 51 35 4;
52 36 37; 53 37 24; 54 38 39; 55 19 40; 56 40 14; 57 19 15; 58 8 40; 61 41 26;
62 41 31; 63 32 41;
ELEMENT INCIDENCES SHELL
59 40 19 15; 60 40 15 14; 64 32 31 33; 65 32 41 31;
ELEMENT PROPERTY
59 60 64 65 THICKNESS 0.05
DEFINE MATERIAL START
ISOTROPIC STEEL
E 2.05e+008
POISSON 0.3
DENSITY 76.8195
ALPHA 1.2e-005
DAMP 0.03
TYPE STEEL
STRENGTH FY 253200 FU 407800 RY 1.5 RT 1.2
END DEFINE MATERIAL
MEMBER PROPERTY TATASTRUCTURA
7 TO 10 19 TO 21 32 36 TO 39 43 47 48 50 TO 53 55 TO 58 61 TO 62 -
63 TABLE ST 66X33X4.5RHS
MEMBER PROPERTY INDIAN
54 TABLE ST ISMC150
CONSTANTS
BETA 90 MEMB 54
MATERIAL STEEL ALL
SUPPORTS
34 TO 37 FIXED BUT FX MZ
Members at junction are ignored in design as there are supports of frame plate which cannot be
modeled here. Other members are found suitable.
This is to certify that structure of MS SLIDING steel gate stability report for vetting
drawings was analyzed and calculations are given in this project report. All the parameters
mentioned in the report are taken in accordance with reference of relevant codes (IS 800 and IS
7718:1991) and good industry practice. The analysis report may be counter checked by
competent authority. Based on the calculations and findings mentioned in the report, the
analyzed structure is certified as stable.
The client Indemnifies the consulting firm for situations beyond the reasonable control of the
firm such as natural disaster, Unauthorized modification of structural members/system,
application of loads other than incorporated in the report, accidents (fire or collision or any
other) which may harm the structure.
The adequacy for the strength of MS sheet and Frame shall be obtained from the
manufacturer. Any ingress of water should be properly checked and corrected.
Based on the analysis conducted, it has been determined that the MS SLIDING steel gate at
IOCL, Gorakhpur Drawing is accurate.; however any deficiencies to be observed should be
notify immediately to authorize officials.
Authorized Signatory