0% found this document useful (0 votes)
22 views2 pages

Vapour & Liquid Flow Rates Vertical Mesh Pad 2 Phase Separator

This document provides the design details for a vertical mesh pad two-phase separator. It includes specifications for nozzle sizing, vapor and liquid separation calculations, vessel sizing, and liquid level settings. Key parameters like flow rates, densities, velocities, and vessel dimensions are presented.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
22 views2 pages

Vapour & Liquid Flow Rates Vertical Mesh Pad 2 Phase Separator

This document provides the design details for a vertical mesh pad two-phase separator. It includes specifications for nozzle sizing, vapor and liquid separation calculations, vessel sizing, and liquid level settings. Key parameters like flow rates, densities, velocities, and vessel dimensions are presented.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Client: 0 Calculation No:

Project: 0 Rev : A Date:


Service:O2 Separator 0 By: Chk'd: App'd:

Vertical Mesh Pad 2 Phase Separator


Vapour & Liquid Flow Rates Vapour Light Liq Total
Mass Flow Rate kg/s = 0.00444 0.54778 0.552
Volume Flow Rate m³/s = 0.00014 0.000567 0.001
Mixture Density kg/m³ = 786.01

Nozzle Sizing

Number Diameter, in Velocity Criteria


Location off Min Select ID m/s Parameter Calcul Allowed Remarks
Feed Inlet 1 1.108717258 2.0 0.05 0.368784 ρmVm² 107 1,000 OK

Vapour Outlet 1 0.155530172 1.0 0.02 0.2913638 ρgVg² 3 4,000 OK


Liquid Outlet 1 1.058149183 2.0 0.05 0.30 Vliquid m/s 0.3 1.0 OK
Size, in No + Size, in No Size, in No
Miscellaneous Vent 2 1 Manholes Utility 2 1
Drain 2 1 Hand holes 8 2 add check valve on utility nozzle

Vapour Separation
Allowable Droplet Size μ = 150.0 0.0002 m
CRe² = 2,343
Log CRe² = 3.4
C = 1.78
Vt, Liquid droplet free settling velocity m/s = 0.18
Allowable Vapour Velocity m/s = 0.61629 User K = 0.1157 Default K = 0.0771
Design Vapour Flow m³/s = 0.00014 80% for compr, glycol, amine drums

Vessel Diameter - Selected D m = 0.65

3.846
Vapour Flow Area m² = 0.332
Vapour Velocity m/s = 0.00041 Less than allowable. OK

Liquid Separation
Vessel Height L m = 2.5

Degassing Area Ag m² = 0.33


Design Liquid Flow m³/s = 0.0005674 Liquid Downward Velocity m/s = 0.0017
Gas Bubble Size - to be removed > μ = 50 Gas Rising Velocity > m/s = 0.0036
* Gas Separation O.K *
Client: 0 Calculation No:
Project: 0 Rev : A Date:
Service:O2 Separator 0 By: Chk'd: App'd:

Vertical Mesh Pad 2


Liquid Phase Separator
Levels
Level Volume IntraVolume Response Time, min Remarks
Settings mm m³ m³ Available Required
Mud Level 0.0
0.05 88 2 sec OK
LALL 150 0.1
0.03 0.97 0.5 OK
LAL 250 0.1
NLL 300 0 0.18 4.0 3.0 OK
LAH 800 0
0.03 0.97 0.5 OK
LAHH 900 0
Control Vol LAL to LAH m³ 0.183 5.4 5.0 OK
Slug Vol NLL to LAHH m³ 0.199 0.00 OK
Slug, inflow all liquid m³/s 0.00 283.4 sec 2 sec OK

Sand Droplet Size & Accumulation


Sand Droplet Size, μ = Later Sand Accumulation, % =
Sand Accumulation per day m³ =

Vessel Size
Vessel Diameter D m = 0.7 Default
LAHH m = 1.0 0.900
Vapour Space below inlet m = 0.4 0.406
0 Inlet Nozzle m = 0.03 0.051
Vapour Space above inlet m = 0.8 0.762
Tan Line to Outlet nozzle m = 0.3 0.312
Minimum Height Required m = 2.48 2.4315

Selected Height L m = 2.50


L/D Ratio = 3.85 OK

Remarks
Space to explain design features, add comments on caution messages