User Manual RoboSpot
User Manual RoboSpot
Version 4.8
RoboSpot Base Station
Table of contents
1. Safety instructions.......................................................................................................... 3
2. Description of the the RoboSpot .................................................................................. 4
2.1 RoboSpot.................................................................................................................... 4
2.2 FollowSpot Controller ................................................................................................. 5
3. Installation....................................................................................................................... 6
3.1 Monitor shield and note holder installation.................................................................. 8
4. RoboSpot connection..................................................................................................... 9
5. Operation....................................................................................................................... 11
5.1 Functions mapping.................................................................................................... 11
5.2 Influence of the RoboSpot on the fixture channels................................................... 14
5.3 LCD monitor screen.................................................................................................. 16
5.4 Streaming a camera video........................................................................................ 25
5.5 Saving and recalling the FollowSpot controller presets............................................ 26
5.6 RoboSpot handles calibration................................................................................... 27
5.7 Multi device control................................................................................................... 28
5.8 Intensity maps........................................................................................................... 43
5.9 PosiStage Net .......................................................................................................... 46
6. Control menu................................................................................................................. 50
6.1 Menu Functions Mapping.......................................................................................... 51
6.2 Menu Show Library................................................................................................... 62
6.3 Menu All Lamps On/Off............................................................................................. 65
6.4 Menu Devices Settings............................................................................................. 65
6.5 Menu RDM Discovery............................................................................................... 65
6.6 Menu DMX In/Out..................................................................................................... 66
6.7 Menu Product IDs..................................................................................................... 66
6.8 Menu Software Version............................................................................................. 66
6.9 Menu Settings........................................................................................................... 66
7. Software update............................................................................................................ 68
8. Error and information messages ................................................................................ 69
9. Technical specifications............................................................................................... 70
10. Maintenance and cleaning.......................................................................................... 72
10.1 Replacing the fuse.................................................................................................. 72
10.2 Disposing of the product......................................................................................... 72
2
FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY
BEFORE YOU INSTALL THE PRODUCT .
1. Safety instructions
CAUTION!
The RoboSpot was designed for indoor use only.
The product is for professional use only, it is not for household use.
This product has left our premises in absolutely perfect condition. In order to maintain this condition and to
ensure a safe operation, it is absolutely necessary for the user to follow the safety instructions and warnings
written in this manual.
DANGEROUS VOLTAGE CONSTITUTING A RISK OF ELECTRIC SHOCK IS PRESENT WITHIN THIS UNIT!
Make sure that the available voltage is not higher than stated on the rear panel of the fixture.
This fixture should be operated only from the type of power source indicated on the marking label. If you are
not sure of the type of power supplied, consult your authorized distributor or local power company.
Always disconnect the fixture from AC power before cleaning, removing or installing a fuse, or any part.
The power plug has to be accessible after installing the fixture. Do not overload wall outlets and extension cords
as this can result in fire or electric shock.
Do not allow anything to rest on the power cord. Do not locate this fixture where the cord may be damaged by
persons walking on it.
Make sure that the power cord is never crimped or damaged by sharp edges. Check the fixture and the power
cord from time to time.
This fixture falls under protection class I. Therefore this fixture has to be connected
to a mains socket outlet with a protective earthing connection.
If the fixture has been exposed to drastic temperature fluctuation (e.g. after transportation), do not switch it on
immediately. The arising condensation water might damage your device. Leave the device switched off until
it has reached room temperature.
Do not shake the fixture. Avoid brute force when installing or operating the fixture.
This fixture was designed for indoor use only, do not expose this unit to rain or use near water.
When choosing the installation spot, please make sure that the fixture is not exposed to extreme heat, moisture,
dust or entertainment smoke (haze)
Air vents and slots in the fixture are provided for ventilation, to ensure reliable operation of the device and to
protect it from overheating.
Operate the fixture only after having familiarized with its functions. Do not permit operation by persons not
qualified for operating the fixture. Most damages are the result of unprofessional operation!
Please consider that unauthorized modifications on the fixture are forbidden due to safety reasons!
3
2. Description of the the RoboSpot
2.1 RoboSpot
4
2.2 FollowSpot Controller
5
3. Installation
The RoboSpot must be installed by a qualified worker in accordance with
all national and local electrical and construction codes and regulations.
Monitor installation
1. Insert the monitor holder (A) into the slot (B) of the RoboSpot and secure it by means of the lock (C).
The lock must be fully screwed and reclined. Check the monitor is securely fastened.
2. Connect the power cable of LCD monitor to the socket (D), HDMI cable and two USB cables to sockets (E)
in the RoboSpot.
Note: The HDMI connection has to be carried out before connecting the RoboSpot to mains.
6
Tripod and adaptor installation
1. Unfold and adjust height of the tripod and distance of legs (8) by means of adjusting locks (4,5,6,7).
The lock (3) has to be in a lower position (as shows arrow on picture below).
2. After inserting the adaptor (1) with spigot (2) to the tripod, the spigot (2) has to be secured by means of
the lock (10) and the adaptor (1) by means of the pin (11) which is inserted to the hole (13) of the adaptor (1)
as shows arrow on picture below. Position of the pin(11) has to be secured by means of the lock (12).
3. The four quarter -turn locks (9) of the adaptor serve for fastening the RoboSpot on the adaptor. Two workers
should install the RoboSpot on the assebled tripod with the adaptor.
Check that all quarter -turn locks (9) are fully tightened before operating the RoboSpot.
Check that all locks (3, 4, 5,6,7, 10,12) are fully tightened before placing
the RoboSpot on the tripod with adaptor.
7
3.1 Monitor shield and note holder installation
1. Place the monitor shield (I) on the monitor holder (A) in this way that pins (J) of the monitor shield snap to
apertures (K) in the monitor holder and move the monitor shield down until you rich a stop.
2. Place the note holder (L) on the monitor shield (I) in this way that pins (M) of the arm (P) snap to the apertures
(N) of the monitor shield (I) and move the arm (P) to the left until you rich a stop.
3. Secure the note holder to the monitor shield by means of the knob (O).
4. Connect two cables of USB lamps to the sockets marked +5V/50mA on the monitor holder.
Note. The arm (P) of the note holder (L) can be turned by 180°, this turned position of the arm allows you to
install the note holder on the opposite site of the monitor shield.
8
4. RoboSpot connection
After installing the RoboSpot, connect it with the ROBIN BMFL FollowSpot with camera (or the RoboSpot Mo-
tionCamera), with another supported ROBIN fixtures and a control desk.
The RoboSpot has to be connected with a desk by means of Ethernet cable and fixtures intended for
the followspot operation have to be connected by means of DMX cable.
You do not need to patch the RoboSpot, but fixtures connected to the RoboSpot have to be patched.
Note: Fixtures connected to the RoboSpot and not supported by the RoboSpot will be ignored by the
RoboSpot.
The desk is holding master intensity for the fixtures. You must open up a dimmer on the desk in order to con-
trol the light intensity from the RoboSpot. If you for example set a dimmer intensity at 50% on your desk, the
RoboSpot operator will have full range of the fader to go from 0-50% of the light intensity.
Max. length of ethernet cable between the FollowSpot with camera and the RoboSpot should not exceed
70 m (if some active component is not used).
Max. length of ethernet cable between the RoboSpot MotionCamera and the RoboSpot should not exceed
70 m (if some active component is not used).
Note. In case of operating the RoboSpot system in interfered environment, Ethernet switches are
recommended in video line (one at the RoboSpot and one at the Robin BMFL FollowSpot or RoboSpot Mo-
tionCamera).
9
In case of using PosiStageNet protocol, you will need to connect an ethernet switch between camera OUT and
camera IN of the RoboSpot in order to get position information from the RoboSpot.
10
5. Operation
After installing the RoboSpot and connecting it with the ROBIN BMFL FollowSpot (RoboSpot MotionCamera)
and another fixtures used for the followspot operation, connect the RoboSpot to mains by means of the en-
closed power cord.
Press the button ACTIVE (1) in order to activate the FollowSpot Controller. By pressing the button PAN (5) and
TILT (6) you can activate/deactivate of the pan/tilt movement of the ROBIN BMFL FollowSpot (and all connected
BMFL fixtures to the RoboSpot).
The button BLACK OUT (2) closes light output of the ROBIN BMFL FollowSpot (and connected fixtures to the
RoboSpot).
It is suitable to set the RoboSpot handlebars to the "middle" position and after that set the pan and tilt position
of the moving head by the sliders on the RoboSpot touch screen.
11
Touch the icon on the FollowSpot Controller to display the password entering screen:
Enter the password (default password is 5242 and also goes for the 15.6" touch screen ) to enter the main
menu of the FollowSpot Controller. The password prevents unauthorized person from changing setting of the
FollowSpot Controller.
Enter the menu "Functions Mapping". The list of available effects will appear:
If the message" Please Activate FollowSpot Controller!" will appear, press the ACTIVE button (1) on the Follow
Spot Controller.
Note. If no fixture is connected to the RoboSpot (or DMX cable is disconnected from the RoboSpot),
the following message will appear:
" Waiting for devices"
"Long touch here to access setting"
In this case touch the display for cca 4 sec. until the screen with icon will appear and you will be able to
enter the main menu of the controller.
2.Press desired button and selected effect will be assigned to its jog-wheel (fader).
Assigned effect is displayed in a yellow colour, free effects stay in a white colour.
3.Repeat steps 1 and 2 for needed effects.
12
4.Touch the [cancel] icon and than [back arrow] icon. The screen with effect faders will appear.
E.g.
Sensitivity of the jog-wheels assigned to the effects can be set at three levels: low, medium and high.
The levels of the sensitivity are marked in colour on the screen:
In order to switch an jog-wheel to desired level of sensitivity, press and hold its activating button (8/10/16/18)
until the colour of fader is changed.
Effects assigned to the four jog-wheels and two faders on the handlebars have a priority over DMX values
coming from a DMX controller.
Functionality of the RoboSpot can by restricted by means of commands on the channel Power/Special Functions
(240-255 DMX) of connected fixture.
13
5.2 Influence of the RoboSpot on the fixture channels
The general rule (with a few exceptions described in the table below) is the RoboSpot controls mapped
channels (functions) on jog-wheels or faders in range which allows the FollowSpot Controller (see the chapter
6.1 Menu Functions Mapping).
Table of behaviour of some mapped channels (functions) on the RoboSpot (if the RoboSpot control is fully
enabled-see the following page).
2. Auto Zoom/Foc.= On
MDC takes control over zoom and focus
regardless of it if they are mapped on
jog-wheels or faders or not.
If zoom and focus are mapped - offsets
set on jog-wheels or faders are added to
automatically calculated values.
If zoom and focus are not mapped -
automatically calculated values are
used (offsets on jog-wheels or faders
are set to 0).
14
The Power/Special Functions channel of supported fixtures offers three control modes of the RoboSpot. You
can use a full control of the RoboSpot, fully disable the RoboSpot or disable the RoboSpot excepting two faders
and manual pan/tilt.
Zoom and focus of fixtures used in the MDC (Multi Device Control) are influenced by setting of the channel
Power/Special Functions, mapping of zoom/focus on the FollowSpot Controller and setting of MDC.
Influence of the settings describes the following table:
Channel Power/Special FollowSpot Controller menu MDC Behaviour of Zoom/Focus
Functions (Multi Device Control)
MDC takes control over zoom
Auto Zoom/Foc.= On and focus (offset set to 50%)
Zoom/Focus are not mapped
Zoom and focus are controlled
Auto Zoom/Foc.= Off by a desk
15
5.3 LCD monitor screen
The RoboSpot is equipped with the 15.6" (10-point) touch screen with max. resolution 1366 x 768.
After switching the RoboSpot and the ROBIN BMFL FollowSpot with camera (or the RoboSpot MotionCamera)
on, image scanned by the camera is displayed on the LCD screen.
To centre the positioning circle on the screen, touch the red cross it until the following dialog box will appear:
Select option Yes and the position circle will be placed to the centre of the screen.
*You can change the name of selected camera. To rename selected camera, touch for two seconds the camera
name (e.g. Camera IP: 10.195.164.171).
The software touch keyboard will appear. Use the keyboard to type a new name of camera (e.g. Camera 1).
Touch ENT to save the new name of the camera. The new name is saved into camera (in case that you will
use other Robospot, the new camera name will be reloaded)
Touch the key X to close the keyboard.
**When you switching between cameras, a box with video synchronization status is displayed. This box shows
a delay between the camera and the screen. The value 0% means max. delay, 100% is without delay (and this
box will disappear from the screen after reaching 100%).
16
*** To lock the screen, touch the button . The following options will appear on the screen:
Lock HUD - this option locks the LCD monitor screen. Positions buttons and pan/tilt movement
by means of the control handlebars are available.
Lock HUD + Controller - this option locks the LCD monitor screen and the FollowSpot Controller
display. The FollowSpot Controller presets and Jog-wheels are available (Jog-wheels have
to be activated before locking the FollowSpot Controller display).
Positions buttons and pan/tilt movement by means of the control handlebars
are also available.
Lock ALL - this option locks all RoboSpot system
To unlock the screen, touch the button and the software touch keyboard will appear. Type a correct pass-
word (the password is the same as the password for the FollowSpot Controller, default password is 5242) and
confirm it by touching the key ENT. Touch the key X to close the keyboard.
Note: the message "Not correct camera settings! Reset camera settings?" informs you that the RoboSpot
software and the camera settings are not accordance.
Use the option "Yes" to set correct camera settings.
The option "Yes" has the same effect as the option "Factory reset " in the Camera button menu.
The message " Last used camera not present. Wait for camera?" informs you that the RoboSpot cannot find
last used camera. If you select Yes, the RoboSpot will still search for last used camera, if you select No, the
RoboSpot will use another founded camera.
After switching the ROBIN BMFL FollowSpot lamp on and adjusting its beam (zoom, focus, dimmer....), aim the
beam to desired position by means of the pan/tilt handles.
Touch and move the position circle on the beam image and set its size in order to match to beam image. Now,
when you move with the control handles, both beam image and position circle on the screen will move syn-
chronously. In case that the light output from the fixture is closed, you know the position of the light beam by
means of the position circle.
Note: if you change a camera zoom, you have to move and adjust the position circle on the beam image again.
17
The green lines in the position circle give pan and tilt position of the control handles.
The green point in the centre of the position circle signals the middle position of the control handles.
If you move with control handles, the distance between the green lines and the red circle will give available
range of pan and tilt movement of the control handles. The red circle poses a " limit" of pan/tilt movement.
Note.
If the pan/tilt control handles requires recalibration, the following screen will appear.
In this case please do a calibration of pan/tilt handles as described in the article "5.5 RoboSpot handles calibration".
18
Sliders menu
Zoom slider- use it to change a zoom of currently selected camera. A sensitivity of a camera zoom can be set
in three levels: low (green slider), medium (yellow slider) and high (red slider).
To change the sensitivity level of the camera zoom, the camera zoom has to be assigned to some jog-wheel
of the FollowSpot Controller, please see the chapter "Functions mapping" how to change sensitivity level of a
slider. After changing of zoom size, picture is automatically focused.
Pan/Tilt sliders - use them to move a moving head to the desired position. A Sensitivity of pan/tilt movement
can be set in three levels : low (green slider), medium (yellow slider) and high (red slider).
In order to switch the sensitivity of pan or tilt movement to desired level, press and hold the PAN (5) or TILT (6)
button until the colour of fader is changed.
Track slider- use it to set desired level of speed of pan/tilt movement. Each level of the track slider responds to
the DMX value of the Pan/Tilt speed channel in DMX chart of BMFL fixture:
Camera menu
Rotate Picture- use this item to rotate a picture on the touch screen 180 degrees from current orientation.
Refocus- use this item to focus an image on the screen (Focus of the camera is set to the "One shot focus "
mode which means that picture is focused automatically after zoom change and the item Refocus allows to
focus the image when the zoom is without change.
19
Exposure- the menu item allows you to choose a level (Low, Medium, High) of light intensity in the position circle
on the screen to see hidden objects from reason of high light intensity in the position circle on the screen. The
item Auto switches the function off.
DayNight mode- the menu item allows you to choose desired colour mode of the camera:
Auto - Normally, video output is set to Color but to B&W under low luminance.
Color - The video output is always in color.
B&W - The video output is always in black and white.
Reconnect- the item disconnects and again connects active camera to the RoboSpot. Use the item in case that
behaviour of the camera is not correct (e.g. long response time).
Factory Reset- use this item to set a camera to the current setting.
All items stated above relate to the selected camera in the menu bar.
Every camera holds information about position of the position circle, its size and picture rotation.
User menu
Blackout Display - use the item to darken the screen. To active the screen, touch it.
Target Cross - use the item to switch on/off the red position circle.
Trace Cursor - if the function is on, a blue circle will appear during (behind a red position circle) which gives a
target position of the position circle (beam image) during its movement.
Position Buttons - if the function is on, the "+" button will appear at the bottom of the screen. Move the position
20
circle to desired position and press the "+" button. Button no.1 will appear at the bottom of the screen and
the button no.1 is assigned to this position of the position circle (if item " Show in scene is active, button no.1
is displayed in the position circle on the screen). You can assign up to 9 buttons to different positions of the
position circle on the screen.
If you touch a position button, the position circle will move to the position of this position button.
Last activated position button is highlighted.
Example (option "Show in Scene" is active):
Show in Scene - the item allows you to show positions of the position buttons on the screen.
In the position button are saved values of the following items: pan position, tilt position, pan/tilt sensitivity,
zoom sensitivity, MDC height, speed, zoom, focus, camera zoom, camera rotation, cross position, cross size.
To edit, rename or remove the position button from the screen, touch desired position button until the message
"Edit, Rename or Delete pos. button X?" appears on the screen and select desired option.
If you select the option "Edit", the following screen with attributes will appear.
Now you can uncheck(check) attributes which you wish to be active in the position point.
Some menu attributes include more functions:
"Position" = pan + tilt + MDC height
"Camera Zoom/Rotation" = camera zoom + camera rotation
"Cross" = size + position
"Sensitivities" = pan sensitivity + tilt sensitivity + zoom sensitivity
21
If you select the option "Rename", the following keyboard will appear on the screen and you can type a new
name (max. 3 characters) for the position point.
Colour Buttons - the function allows you to change colour on used fixtures together. The function controls colour
channels (Red/Green/Blue/White/CTO channels at LEDs fixtures and Cyan/Magenta/Yellow channels at lamp
fixtures). When choosing desired colour, corresponding channels are taken over from a desk to the Robospot.
Colour bar
22
Touch the button + and the following screen will appear.
Use the circular picker to choose a desired colour. The chosen colour can be "send" to fixtures by pressing the
button Set or saved to the colour bar at the bottom of the screen by pressing the button Save. Up to 8 colour
buttons can be saved to the colour bar. Only RGB or CMY colours can be controlled via the circular picker.
Desired colour can be activated by touching its button in the colour bar.
The Desk Colour button passes colour channels on to the control from a desk.
If you want to delete or rename a colour button, touch and hold a finger on the colour button until the following
message appears " Rename or Delete colour button X?".
When you choosing option " Rename", the virtual keyboard will appear and you can type name of colour (max.
3 characters).
23
The option "Export to USB" allows you to save colour buttons to the file on the USB flash drive.
To export colour buttons.
1. Connect a USB flash drive to the USB port marked USB 50mA.
2. Select option "Export to USB".
3. The virtual keyboard will appear on the screen. Type the name of file (e.g. colors1) and confirm it by the key
ENT. The colours file on the USB flash drive will have extension rscb (e.g. colors1.rscb).
The option "Import from USB" allows you to import colour buttons from the file on the USB flash drive.
To import colour buttons.
1. Connect a USB flash drive to the USB port marked USB 50mA.
2. Select option "import from USB".
3. Select a colour buttons file (e.g. color2.rscb) which you want to load from the USB flash drive and touch the
button Import.
This option also allows you to delete colour buttons file from the USB flash drive.
Multi Dev.Control - the menu serves for activating and setting control of fixtures in the multi device operation.
For more information please see the chapter Multi device control.
24
Service menu
Network Test - the item runs a connection test between a camera and the RoboSpot. During the test, do not
touch any buttons on the FollowSpot controller.
DMX Dimmers - the item shows value of dimmer for each fixture (in %). This dimmer value of
the corresponding fixture is calculated from a DMX value of dimmer sent from a desk to the fixture and a position
of fader or Jog-wheel (depends on fixture mapping).
E.g. DMX value for dimmer sent from the desk to a fixture is 120, by means of the fader (Jog-wheel) this value
can be changed from 0 DMX to 120 DMX.
example: rtsp://10.195.165.223/profile2/media.smp
25
5.5 Saving and recalling the FollowSpot controller presets
The FollowSpot Controller offers you to save up to 12 presets.
2. Press flashing button of effect which value you wish to add to the current preset (the button will start light
continually).
3. Press and hold selected preset button until the jog-wheels activating buttons stop to flash.
The preset button will light.
Note: Every user preset can have different FollowSpot Controller presets which are saved into the user preset
file. This file can be saved on a USB flash drive.
Note: you can write notes on the white fields of the FollowSpot Controller, use a marker on an alcohol base and
a suitable cleaning liquid (on alcohol base) for removing the notes. Never use solvents!
26
5.6 RoboSpot handles calibration
To calibrate the RoboSpot handles.
1. Install the FollowSpot Controller on the FollowSpot Controller base
1. Deactivate the FollowSpot Controller (button ACTIVE (1) must not light)
2. Move the control handles of the RoboSpot to the calibration position, in this way:
pan direction - move handles fully to the left until you reach a stop
tilt direction - move handles fully down until you reach a stop
3. Keep handles in the calibration position and press and hold the PAN button (5) for circa 6 seconds until this
button makes one flash - it is a finish of the calibration and you can use the FollowSpot Controller.
Move handles to
the left to reach Move handles down to
the stop reach the stop
27
5.7 Multi device control
The RoboSpot can support more fixtures in the follow spot operation.
The fixtures used in the follow spot operation should be placed on a truss around the area intended for the follow
spot operation. The fixtures can be placed above stage on one ( two or three) side(s) of the stage or around
the stage, placing inside the working area for the follow spot operation is not suitable .
Some examples of possible arrangements of fixtures above the stage:
28
Fixtures cannot stay directly on the stage floor. They have to be placed above the stage floor in two positions
only: head downwards or head upwards.
29
Important notes for the MDC (Multi Device Control) setup
- If you use the Robin BMFL FollowSpot with a camera, do not switch its lamp off and do not close its light
output during the MDC setup.
- If you use the RoboSpot Motion Camera, set the red positioning circle to the centre of the screen before
starting the MDC setup.
- The plane of fixture´s hanging and the plane of the stage have to be parallel in relation to each other (this
condition applies to two position points only).
- Calibration points must be on the same level on the stage.
- Both pan inversion and tilt inversion have to be set OFF before starting the MDC setup a MDC operation.
MDC sets inversion automatically, if it is needed.
- Small imprecisions of fixture´s hanging in a horizontal plane can significantly affect resulting movement
of the fixtures.
- Small imprecisions during MDC setup (calibration points, height) may result in large offsets and inaccurate
movement of the fixtures.
If you use the Robin MegaPointe or the Robin Pointe in MDC, both static and rotating gobo wheels are
blocked (they cannot be controlled by DMX desk) during MDC setup and the follow spot operation.
30
There is an example how to create the follow spot operation for three fixtures and two position points.
The stage is lighted by the five devices in a row and three of them will be used for the follow spot operation.
1. Enter the "Multi Dev. Control" menu on the screen and select the option "Setup MDC".
Note: If you use the RoboSpot Motion Camera, set the red positioning circle to the centre of the screen before
starting the MDC setup.
2. After entering the item " Setup MDC" the following message will appear on the screen:
Note: The message "Please Map Zoom and Focus channel to wheels!" reminds you that both zoom and focus
have to be mapped jog-wheels of the FollowSpot Controller (only if the option "Auto Zoom/Foc" is active).
Select fixtures which will be used for the multi device control (e. g. DL7S, MegaPointe, BMFL FollowSpot).
31
Note: In case that setup of DMC has been created, the following message will appear:
Select the option "Load" if you want to load existing setup and modified it.
Touch the "Next" button.
Three fixtures are selected for the multi device operation.
Select desired reference device from devices intended for the multi device control (the reference device should
be a device with a camera /BMFL FollowSpot with camera or RoboSpot Motion camera)/ and should not be
placed on the edge of fixtures row, optimal position is in the middle of fixtures /if it is possible/, in this case it
is the BMFL FollowSpot).
The pan/tilt position of the reference device is directly controlled by means of the RoboSpot handles.
The pan/tilt positions of remaining devices in the multi device control are calculated in relation to the reference
device.
Touch the "Next" button.
32
Zoom and iris are automatically set to the narrow beam at all devices used in the follow spot operation.
Activate one fixture (by touching its button or using arrows), e.g. BMFL FollowSpot, focus it (by means of the
FollowSpot Controller) and aim it to the first point on the floor (by means of the RoboSpot handles) as exactly
as possible.
Repeat this action for another two fixtures.
Blackout buttons
Use the jog-wheels on the FollowSpot Controller (or faders on the screen) to set desired zoom and focus in
the point 1 for each fixture.
33
6. The following message will appear on the screen:
Zoom and iris are automatically set to the narrow beam at all devices used in the follow spot operation.
Activate one fixture (by touching its button), e.g. BMFL FollowSpot, focus it (by means of the FollowSpot Con-
troller) and aim it to the second point on the floor (by means of the RoboSpot handles) as exactly as possible.
Repeat this action for another two fixtures.
The two points should be placed sufficiently apart on the floor and situated inside the field which is
intended for the follow spot operation. The two points should not be placed too close and must be in the same
level on the stage.
Two position points has to be placed on the stage in a way that all fixtures used in the follow spot operation
have to change both pan and tilt values when go (light) from the 1st point to the 2nd point.
34
In the following example the fixture 3 does not change its pan value (only tilt value) when head moves from the
1st point to the 2nd point, the 2nd point is not selected correctly.
7. Touch the Next button, the following message will appear on the screen:
35
Use the jog-wheels on the FollowSpot Controller (or faders on the screen) to set desired zoom and focus in
the point 2 for each fixture.
For information: if the option Multi device control is activated, both zoom and focus on all devices are set at
50%. The values are offsets in relation to the zoom and focus values set at the first and the second point.
Now you can test the multi device control (by means of the RoboSpot handles). If it is OK, touch the "Save"
button or you can use the "Prev" button to move one or more steps back and change setting.
The button "Info" shows information about current positions of fixtures used in the follow spot operation.
Example:
36
x,y,z - relative coordinates of the device in relation to the reference device
Rx,Ry,Rz - rotation of the device in x, y and z axes
SRx, SRy - rotation of the stage towards to reference device
Rs - rotation of the stage towards to working space
The button "Adj." allows you to go back in the setting procedure and correct settings of devices in the first and
all following points. The following screen will appear.
Note:
If the plane of fixture´s hanging and the plane of the stage is parallel in relation to each other, two position
points should be enough.
If the plane of fixture´s hanging and the plane of the stage is not parallel in relation to each other or the result
of MDC is not satisfactory, you will need to set another position point (or points).
To move to the third position point setting, touch the "Next" button.
Do settings for the third position point as you did for the second point and check that MDC works correctly.
If you use 3, 4 or 5 position points, they should be placed sufficiently apart on the floor and situated inside the
field which is intended for the follow spot operation. They must not be placed too close each other and must be
in the same level on the stage (because of correct operation of the function Height mode).
37
To activate the multi device control, touch the button "On/Off.
If the item "Auto Zoom/Foc." is active, the zoom and focus of fixtures used in the follow spot operation
will be carried out automatically (in a range as was adjusted in "1st point" and "2nd point") during moving of
the light image on the stage. If the item "Auto Zoom/Foc." is deactivated, zooming and focusing of fixtures has
to be done manually.
If the item "Auto Zoom/Foc." is active, neither static gobos nor rotating gobos can be changed at the Robin
Pointe/MegaPointe/iPointe (gobos are set to the specific positions). If the item "Auto Zoom/Foc." is deactivated,
the gobos can be changed as you need.
During the follow spot operation you can deactivate any device (except the reference device). The deactivated
device remains in the original position and the rest of devices will continue in the follow spot operation. When
you activate this device back, the device "jumps" to the follow spot operation.
38
Robin DL7S is activated (by touching the button DL7S).
39
9. When the Multi Device Control is on, select suitable Height Mode.
Note: the item Height has to be mapped to some fader or jog-wheel in order to control it during multi device
operation.
Person mode Stairs mode
Height bar.
40
To set the height level range, touch and hold your finger on the height bar until the following message will appear.
Use the he fader or jog-wheel (according to the height mapping) to set minimum height level and touch the
Next button.
The following message will appear.
Use the he fader or jog-wheel to set maximum height level. Difference between max. and min. height level has
to be 5% or more, from the reason you cannot set the max. level at value < 5% compared to min. level.
Touch the Next button, the test screen with the following message will appear.
Use the he fader or jog-wheel to test the height level range, if it is OK, touch the Save button to save the height
level range.
Note. The fader (or jog-wheel) uses its full track for control of the height level range.
41
Examples of height level ranges.
42
5.8 Intensity maps
The RoboSpot allows you to set a light intensity in different points in the area intended for the follow spot
operation. The light intensity can be set separately for each fixture used in MDC operation.
Setup
Before doing Intensity maps, map height and dimmer channels to jog-wheels (not to faders!)
Go to the menu "Intensity Maps" and select the option "Setup".
The message "Please map Dimmer and Height channels to wheels" reminds you a need of mapping of dimmer
and height channels to the jog-wheels.
By touching the screen, the message" Please map Dimmer and Height channels to wheels" will disappear.
Use the RoboSpot´s handles to aim the light beam to desired first position point (position points in the Inten-
sity Maps Setup may be different from position points used in MDC setup) and touch the "Next" button. The
following screen will appear.
43
Now set desired light intensity for each fixture (activate fixtures one by one by touching it).
E.g.
After setting the light intensities, touch the "Next" button. The screen for the second point will appear.
Use the RoboSpot´s handles to aim fixtures to desired second position point and touch the "Next" button. The
following screen will appear.
Set desired light intensity for each fixture (activate fixtures one by one by touching it).
In this way you can select up to 20 position points and set the light intensity in them.
After setting light intensity in last position point (e.g. point 4), touch the "Test" button and the following screen
will appear.
Move the light beam to desired positions (by means of the RoboSpot´s handles) and test the light intensity in
these positions. If it is OK, touch the "Save" button to save set values to the RoboSpot.
44
Setting the dimmer curve
The menu Intensity Maps allows you to select a linear or square law dimmer curve. Selected dimmer curve
applies to all fixtures used in MDC setup.
When you switching between dimmer curves, the message " Setting dimmer curve for MDC lights to linear" or
" Setting dimmer curve for MDC lights to square law" will appear for a while informing you, the command for
activation of selected dimmer curve is sending to fixtures.
Note. The message stated above also will appear when you activate the Intensity Maps (item On/Off)
Dimmer curves in individual fixtures are temporarily overwritten (by means of the command on the channel
Power/Special Functions).
Note: if you select a dimmer curve and than you switch some fixture off and on, the fixture will use a dimmer
curve set in the menu of this fixture (not curve set in the Dim. Curve menu).
Intensity transition
The menu Intensity Transition offers you three modes (Smooth, Medium, Sharp) of a "light transition" from one
position point to another.
The light intensity in the Smooth mode decreases faster around position point during movement from one po-
sition point to another than in the Medium or Sharp mode.
45
5.9 PosiStage Net
The menu option allows you to use a PosiStageNet protocol (an open protocol for on-stage, live 3D position data).
Before activating the PosiStageNet protocol, the MDC setup has to be complete. The PosiStageNet protocol
is active on both Ethernet connectors (Camera IN/Update, Ethernet ) of the RoboSpot.
The item "Ref. Height" allows you to set a height (in mm) of a tilt axis of the reference fixture above the stage.
46
The item "Set Offset" allows you to set offset of the new origin of coordinates.
The values in the field XYZ offset (e.g. -0.038 0 0.189) have to be separated by a space.
The item "Show Coord." allows you to display PSN coordinates on the screen.
Example: if you want to set origin of coordinates from point P0 to point P1, do the following steps:
47
3. Aim the beam of reference fixture from point P0 to Point P1. Current coordinates of the point P1 will be dis-
played in the PSN Coordinates window.
Example:
x: 0.038
y: 0.000
z:-0.189
4. Select the option "Set Offset" and type the values from the PSN Coordinates window (with opposite signs)
into the field XYZ Offset Values.
Example:
x:-0.038
y: 0.000
z: 0.189
Values xyz have
to be separated
by a space!
5. After pressing the ENT button, new origin of coordinates will be saved and the XYZ coordinates in the PSN
Coordinates window will be set to 0.
Example:
Last three items in the PosiStage Net menu allows you to set Tracker ID, PSN port and PSN Address.
48
49
6. Control menu
The FollowSpot Controller is equipped with the QVGA Robe touch screen with battery backup which
allows you to set the device behaviour according to your needs.
- [confirm] used to save adjusted values and leave menu or to perform desired action.
Enter the default password (5242) to enter the main menu of the FollowSpot Controller. The password prevents
unauthorized person from changing setting of the FollowSpot Controller (password can changed or switched
off via the menu Settings).
Main menu
Page 1 Page 2
50
6.1 Menu Functions Mapping
By entering the menu you can assign effects from the list of available effects to the jog-wheels and faders.
List of available effect channels depends of the used moving head. The item All - releases all assigned effects
at one go.
Note: The FollowSpot Controller does not allow to control full DMX range (0-255) of some effects, available
DMX values for each effect are stated in the tables below.
The item "Heigh." (Height) is not stated in tables below and serves for Multi Devices Control.
51
Fixture Effect Available DMX values
Dimmer 0-255
Iris 0-179
Focus 0-255
Zoom 0-255
L Frost 0,1-50
M Frost 0,87-136
H Frost 0,173-222
Color 1 0,130-189
Color 2 0,130-189
Cyan 0-255
Magenta 0-255
Yellow 0-255
CTO 0-255
Efw. pos 0-127
Robin BMFL Blade Efw. rot 0-255
SGW 0, 8-103
RGW 1 0,32-59
RGW r1 0-255
Prism 0-127
Pris r 0-255
FS rot 0-255
FS 1 m 0-255
FS 1 s 0-255
FS 2 m 0-255
FS 2 s 0-255
FS 3 m 0-255
FS 3 s 0-255
FS 4 m 0-255
FS 4 s 0-255
52
Fixture Effect Available DMX values
RGW 1 0,32-59
RGWr 1 0-255
FS rot 0-255
FS 1 m 0-255
FS 1 s 0-255
Robin BMFL WashBeam FS 2 m 0-255
FS 2 s 0-255
FS 3 m 0-255
FS 3 s 0-255
FS 4 m 0-255
FS 4 s 0-255
53
Fixture Effect Available DMX values
Dimmer 0-255
Iris 0-179
Focus 0-255
Zoom 0-255
Frost 0-179
V Color 0-247
Red 0-255
Green 0-255
Blue 0-255
White 0-255
CTO 0-255
Efw. pos 0-127
Efw. rot 0-255
Robin DL4S
RGW 0, 32-59
RGW r 0-255
Prism 0-127
Pris r 0-255
FS rot 0-255
FS 1 m 0-255
FS 1 s 0-255
FS 2 m 0-255
FS 2 s 0-255
FS 3 m 0-255
FS 3 s 0-255
FS 4 m 0-255
FS 4 s 0-255
54
Fixture Effect Available DMX values
Color 1 0, 130-189
V Color 0-132
Efw. pos 0-127
Efw. rot 0-255
SGW 0, 4-87
Robin MegaPointe RGW 1 0, 32-59
Robin iPointe RGWr 1 0-255
Robin iPointe65 Prism 1 0-27
Pris1 r 0-255
Prism 2 0-27
Pris2 r 0-255
Beam 0-19
Beam r 0-255
55
Fixture Effect Available DMX values
Dimmer 0-255
Red 0-255
Green 0-255
Robin Spiider Blue 0-255
Robin iSpiider
Robin Tarrantula White 0-255
CTO 0-255
Zoom 0-255
A. Zone 0-72
56
Fixture Effect Available DMX values
Dimmer 0-255
Iris 0-179
Focus 0-255
Zoom 0-255
L Frost 0, 1-50
M Frost 0, 87-136
H Frost 0,173-222
Color 1 0,130-189
Color 2 0,130-189
Cyan 0-255
Magenta 0-255
Yellow 0-255
CTO 0-255
Efw. pos 0-127
Robin Esprite
Efw. rot 0-255
Robin Esprite FS
SGW 0, 9-91
RGW 1 0,32-59
RGW r1 0-255
Prism 0-127
Pris r 0-255
FS rot 0-255
FS 1 m 0-255
FS 1 s 0-255
FS 2 m 0-255
FS 2 s 0-255
FS 3 m 0-255
FS 3 s 0-255
FS 4 m 0-255
FS 4 s 0-255
57
Fixture Effect Available DMX values
Dimmer 0-255
Focus 0-255
Zoom 0-255
Color 1 0,130-189
Cyan 0-255
Magenta 0-255
Yellow 0-255
CTO 0-255
Efw. pos 0-127
Efw. rot 0-127
RGW 1 0,32-59
Robin MMX Blade
RGWr 1 0-255
Prism 0-127
Pris r 0-255
Frost 0-179
Iris 0-179
FS rot 0-255
FS 1 m 0-255
FS 2 m 0-255
FS 3 m 0-255
FS 4 m 0-255
Hot S. 0-255
58
Fixture Effect Available DMX values
FS 2 s 0-255
FS 3 m 0-255
Robin T2 Profile
FS 3 s 0-255
FS 4 m 0-255
FS 4 s 0-255
59
Fixture Effect Available DMX values
Dimmer 0-255
Focus 0-255
Frost 0-179
Color 0,130-189
Cyan 0-255
Magenta 0-255
Robin Cuete
Yellow 0-255
SGW 0,10-89
RGW 0,32-59
RGW r 0-255
Prism 0-127
Pris r 0-255
Power 225-239
60
Fixture Effect Available DMX values
Dimmer 0-255
Focus 0-255
Frost 0-179
Color 0,130-189
Cyan 0-255
Magenta 0-255
Yellow 0-255
V Color 0-132
CTO 0-255
SGW 0,9-91
RGW 0,42-73
RGW r 0-255
Robin Painte
Prism 0-127
Pris r 0-255
Frost 0-179
Iris 0-179
FS rot 0-255
FS 1 m 0-255
FS 1 s 0-255
FS 2 m 0-255
FS 2 s 0-255
FS 3 m 0-255
FS 3 s 0-255
FS 4 m 0-255
FS 4 s 0-255
Power 225-239
61
6.2 Menu Show Library
Select/Rename Show - the menu item offers 10 shows. In the show is saved setting of the RoboSpot system:
Functions mapping
FollowSpot Controller presets
Sensitivity of jog-wheels
Faders switching and inversion
Position buttons
DMX addresses and modes of connected devices
RDM information about connected devices (only if the option "Manual" is selected in the menu "Discovery
Settings")
Note: values in the menu Ethernet settings (menu Settings) are not saved to the show.
The show can be saved on a USB flash drive and loaded back to the RoboSpot .
Down
Confirm
Rename
Confirm Cancel
To select a show.
Select desired show by touching its button and confirm it. The notice: "Switch To Show OK" will appear for a
moment on the screen.
Selected show is displayed in the bottom right corner of the LCD screen.
All changes in setting of the RoboSpot made by the user are immediately saved into
the selected show.
To rename a show.
1. Select desired show by touching its button.
2. Touch the Rename icon. The virtual keyboard will appear on the LCD screen with selected show, e.g. Show 3.
3. Now you can edit the name of the show and confirm it by the key ENT.
62
Export Show - the menu item allows you to save a show on a USB flash drive connected to the USB port of
the RoboSpot. Supported file systems of the USB flash drive are: FAT16, FAT32, EXT2, EXT3, EXT4.
To export a show.
1. Connect a USB flash drive to the USB port marked USB 50mA.
2. Select desired show (e.g. Show 3) and confirm it.
3. The virtual keyboard will appear on the screen with a name of the show file. You can edit the name of the
show and confirm it by the key ENT. The show file on the USB flash drive will have extension rsl
(e.g. RSShowLibrary-03.rsl).
If the import is successful, the notice: "Export Show OK" will appear for a moment on the screen.
Import Show - the menu item allows you to load a show file saved on a USB flash drive connected to the USB
port of the RoboSpot.
To import a show.
1. Connect a USB flash drive to theUSB port marked USB 50mA.
2. Select a show (e.g. Show 1) to which you want to load a show file from the USB flash drive and confirm it.
63
3. The list of available show files on the USB flash drive will appear on the LCD screen e.g.
4.Select desired show file (e.g. Show 6.rsl) and touch the button "Import" to load selected show file to
the RoboSpot. If the import is successful, the notice: "Import Show OK" will appear.
You can also delete selected show from the USB flash drive by means of the option "Delete".
Note. You can load to selected show any show file, for example, to the show 10 you can load the file RSShowLi-
brary-02.rsl. Original show file in the show 10 will be overwritten.
New Show - the menu item allows you to crate a new show.
Select a show (e.g. RS Show 3) in which you want to create the new show and confirm it. Original show (saved
in RS Show 3) will be deleted.
64
6.3 Menu All Lamps On/Off
The menu item allows you to switch on/off lamp in the Robin BMFL FollowSpot and fixtures connected to this
Robin BMFL FollowSpot.
Touch desired device and the following menu items will appear.
Set Device Label - the menu item allows you to rename actual device. Touch the item
until the keyboard will apear on the touch screen. Use the key <-- to delete original
name of the device and type a new name. Confirm it by means of the key ENT.
Pan Offset - allows you to set a pan offset in the range of +/-100% .
Tilt Offset - allows you to set a tilt offset in the range of +/-100%.
Zoom Offset - allows you to set a zoom offset in the range of +/-100%.
Focus Offset - allows you to set a focus offset in the range of +/-100%.
Lamp On/O - allows you to switch on/off lamp of the device
Pan/Tilt reverse - allows you to reverse the pan/tilt movement of the device.
DMX Address - allows you to set DMX address of the device.
DMX Preset - allows you to select DMX mode of the device.
Device Default Settings - sets all items stated above (except DMX Address and DMX Preset)
to the default (factory) values.
Set To Def. In Preset - sets items of devices displayed in the menu "Devices Settings" to default values. This
function affects the active user preset only.
Set All To Defaults - sets items of devices displayed in the menu "Devices Settings" to default values. This
function affects all user presets.
In case that some fixtures connected to the RoboSpot are on the same DMX address or have overlaping chan-
nels, the following message will appear:
65
If you select option the Yes, collision fixtures will be automatically readdressed.
If you select No, DMX addresses wil stay without change.
System Test - the menu allows you to test jog-wheels, faders and pan/tilt movement of the RoboSpot.
Ethernet Settings - the menu allows you to set the RoboSpot for the Ethernet operation
Ethernet Mode
Artnet - Fixture receives Artnet protocol
gMAI - Fixture receives MANet I protocol
gMA2 - Fixture receives MANet 2 protocol
sACN - Fixture receives sACN protocol
IP Address/Net Mask - select this menu to set IP address. IP address is the Internet protocol
address.The IP uniquely identifies any node (fixture) on a network.
There cannot be 2 fixtures with the same IP address on the network!
Default IP Address -Preset IP address, you can set up only first byte of IP address
(2 or 10) e.g. 002.019.052.086.
Custom IP Address - The option enables to set up all bytes of IP address.
Net Mask - The option enables to set up all bytes of Net Mask.
ArtNet Universe - use this item to set a Universe (0-255). The Universe is a single DMX
512 frame of 512 channels.
MANet Settings - use this menu to set parameters for MANet operation.
MANet Universe I/II - The value of this item can be set in range 1-256.
MANet Session ID - The value of this item can be set in range 1-32.
sACN Settings - use this menu to set parameters for sACN operation.
sACN Universe - The value of this item can be set in range 1-32000.
66
sACN Priority - The value of this item can be set in range 0-255.
Discovery Settings - the menu item allows you to set a behaviour of the RoboSpot during RDM discovery
process (menu item RDM Discovery) and after switching the RoboSpot on.
Auto - the RoboSpot searches connected devices after each switching it on and does not save
the list of discovered devices. Also If the option RDM Discovery is run, the list of discovered devices
is not saved.
Manual - the RoboSpot searches connected devices and save the list of discovered devices.
When the RoboSpot is switched on, the saved list of discovered devices will be load to the RoboSpot
and (even in case that fixtures are not be connected to RoboSpot) the RoboSpot will not run
the discovery procedure.
Controls invert - the menu item allows you to invert pan/tilt and faders of the RoboSpot.
Default settings of faders: fader down-minimum (0 DMX), fader up-maximum (255 DMX).
Camera Rotation - the function rotates a camera picture on the monitor 180 degrees from the current orientation.
Shutter Pass On - the function has influence on behaviour of shutters of connected fixtures.
Off - After switching the RoboSpot on, shutters will be closed until you activate the FollowSpot Controller
(by pressing the button ACTIVE). After its activating, fixtures can receive DMX values for shutters
from control desk.
On - After switching the RoboSpot on, shutters can be controlled from the desk without activating
the FollowSpot Controller.
Ctrl.On When PWR On - if the function is on, the Pan/Tilt buttons of the FollowSpot Controller are auto-
matically activated after connecting power to the FollowSpot Controller.
Password Settings - the menu item allows you to change the password or switch it on/off at entry the FollowSpot
Controller menu. The password applies to the FollowSpot Controller as well as to the RoboSpot 15.6" screen.
Change password - use this option to change password. Default (factory) password is 5242.
Protect with Password - If this function is on, the password is required at entry the FollowSpot
Controller menu.
Note: both menu items stated above require inserting of password to enter them even the password is
set off ! You have to remember the last set password!
In case you have forgotten your password, use the master password 4678.
Recalibrate Touchscreen - the item starts calibration of the touchscreen. Follow instructions on
the screen.
Default Settings - The menu item allows you to set the FollowSpot Controller and LCD monitor to the default
(factory) values separately.
Note: The FollowSpot Controller menu will be set to default values except Ethernet Settings.The password will
not be set to a default password (set password will remain without change) but the option Protect with Password
will be set to On.
67
Via LCD monitor will be set to default values also Raspberry device in the Robospot base and its settings: MDC
setup, dimmer mapping, shows,position and colour buttons, cursors....
7. Software update
RoboSpot software update is done via a network connection between a computer running a ROBE RDM Up-
loader software through the CAMERA input (RJ45) of the RoboSpot base station. It is important to note, that
computer IPv4 address has to be set to 10.x.x.x network (for example 10.0.1.10) with netmask 255.0.0.0 .
During the update, the FollowSpot Controller has to be attached to the RoboSpot.
Do note, that to enable all new features, you must update the RoboSpot base station and also all BMFL fixtures
controlled by the RoboSpot system.
To update software in the Robospot.
1. Connect a computer running ROBE RDM Uploader to the internet and update software libraries (Libraries
→ Update)
2. Connect the computer and the RoboSpot base station via Ethernet cable. Use the RJ45 socket marked
Camera IN/Update on the RoboSpot base station for this connection.
3. Set computer to address 10.x.x.x/255.0.0.0 (do note the 10.x.x.x). Do not change any IP settings on the
RoboSpot.
4. Use the ROBE Uploader → Devices → Discovery and Devices → Update. This will update RoboSpot together
with the attached FollowSpot Controller panel. The message "Flashing Mode. Please do not touch any buttons!"
will appear on the RoboSpot screen during updating process.
68
8. Error and information messages
Error message message is signalled by the warning icon in the right top corner of the RoboSpot screen:
Touch the warning icon to display a message. Touch the screen to hide the message.
List of error and information messages:
This picture on the RoboSpot screen informs you that the Raspberry engine inside the RoboSpot does
not have a sufficient voltage on its input (e.g. you have connecred connected a USB flash drive with high power
consumption).
69
9. Technical specifications
Supported fixtures: BMFL FollowSpot / FollowSpot LT, BMFL Spot, BMFL Blade, BMFL WashBeam,
BMFL WashBeam EV, Esprite, Esprite FS, Forte, Forte FS,i Forte , iForte FS
T1 Profile, T1 Profile FS, T2 Profile, T2 Profile FS, DL7S Profile, DL4S Profile, iSpiider,
iBeam 250, iPointe65, MegaPointe, Pointe, Painte, Spote, Cuete, ProMotion, Viva CMY,
SilverScan, Tarrantula, Spiider, LEDBeam 150, LEDBeam 350™
Input voltage: 100-240V AC
Power consumption: 15W (power factor=0.43, I=0.12A at 230V)
Fuse: T 2 A
LCD Monitor: ASUS VT168 H (panel size:15.6" , max. resolution:1366 x 768)
Setting & Control: graphic touch screen
Protocols: RDM, ArtNet, sACN,gMA I, gMA II,
support of PosiStageNet protocol on both outputs (Camera, Ethernet)
Control elements: 20 buttons, 4 jog-wheels and 2 faders
Connection: DMX In/Out: Locking 3-pin and 5-pin XLR
Ethernet: RJ 45
Camera: RJ 45
AC power: Neutrik PowerCon, A-type, NAC3MPA
Monitor: HDMI
USB lamp: 2x USB socket +5V/50mA
1 x USB
Pan range: +/- 80°
Tilt range: +/- 40°
Fastening: via adaptor on tripod
Maximum ambient operating temperature : 40° C
Minimum ambient operating temperature: 0°C
Dimensions (mm)
70
Dimensions with monitor shield and note holder (mm)
Weights: 16.5 kg (RoboSpot), 1.9 kg (Monitor Shied + Note Holder), 1.7kg (Adaptor), 8.7 kg (Tripod)
Included items
1 x RoboSpot
1 x Adaptor (including spigot) (P/N 99015404)
1 x Tripod for RoboSpot/FollowSpot/LightMaster (P/N 10980350)
1 x Power cable
1 x User manual
Optional accessory
Monitor Shield and Note Holder for RoboSpot BS (P/N 10980409)*
Monitor Shield and Note Holder II for RoboSpot BS (P/N 10980678)
Water-resistant RoboSpot system protection cover (P/N 23049107)
71
10. Maintenance and cleaning
DANGER !
Disconnect from the mains before starting any
maintenance work
A soft lint-free cloth moistened with cleaning fluid is recommended, under no circumstances should solvents
be used! For cleaning of the LCD monitor use a fluid intended for this purpose.
More complicated maintenance and service operations are only to be carried out by authorized distributors.
1) Remove the fuse holder on the rear panel of the base with a fitting screwdriver from the housing (anti-clockwise).
2) Remove the old fuse from the fuse holder.
3) Install the new fuse in the fuse holder (only the same type and rating).
4) Replace the fuse holder in the housing and fix it.
72