This document provides a table listing function parameters for an NICE900 user manual. The table includes over 30 function parameters related to door opening and closing speeds, times, torques and more. Each parameter includes its name, setting range, minimum unit, and default value.

Uploaded by

tne tne
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
33 views11 pages

NICE3

This document provides a table listing function parameters for an NICE900 user manual. The table includes over 30 function parameters related to door opening and closing speeds, times, torques and more. Each parameter includes its name, setting range, minimum unit, and default value.

Uploaded by

tne tne
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 11

Function parameter table NICE900 User Manual

Function Change
Name Setting range Min.unit default
code properties
Open door startup
F301 0.1~999.9s 0.1s 1.0s ☆
acceleration time
Speed control
open door startup
F302 0.1~999.9s 0.1s 1.0s ☆
low speed run
time

Open door freq.


F303 0.00Hz~F003 0.01Hz 25.00Hz ☆
setting
Open door
F304 0.1~999.9s 0.1s 2.0s ☆
acceleration time
Open door end
F305 0.00~F303 0.01Hz 3.00Hz ☆
low speed setting
Open door
F306 0.1~999.9s 0.1s 2.0s ☆
deceleration time
Open door locked-
rotor to torque 0.0%~150.0% motor rated
F307 0.1% 50.0% ★
holding switch torque
point setting
Open door arrival
F308 0.0%~F307 0.1% 50.0% ★
torque holding
Door-open
F309 0.0%~150.0% rated torque 0.1% 80.0% ☆
blocked torque
Door-open startup
F310 0.0%~150.0% rated torque 0.1% 0.0% ★
torque
Door-open
F311 blocked judging 0~9999ms 1ms 0ms ☆
time
F4-close-door run parameter
Close-door startup
F400 0.00Hz~F403 0.01Hz 4.00Hz ☆
low speed setting
Door-clsoing start
F401 0.1~999.9s 0.1s 1.0s ☆
acceleration time
Speed control
door-closing start
F402 0.1~999.9s 0.1s 1.0s ☆
low-speed run
time
Door-closing high-
F403 0.00Hz~F104 0.01Hz 12.00Hz ☆
speed setting
Door-closing
F404 0.1~999.9s 0.1s 2.0s ☆
acceleration time

30
NICE900 User Manual Function parameter table

Function Change
Name Setting range Min.unit default
code properties
Door-closing end
F405 0.00Hz~F403 0.01Hz 2.00Hz ☆
low-speed setting
Door-closing
F406 0.1~999.9s 0.1s 1.5s ☆
deceleration time
Door-closing low-
F407 0.00Hz~F403 0.01Hz 1.00Hz ☆
speed setting
Door-closing low-
F408 1~9999ms 1ms 300ms ☆
speed run time
Skate withdraw
F409 0.00Hz~F403 0.01Hz 2.00Hz ☆
speed setting
Skate withdraw
F410 1~9999ms 1ms 500ms ☆
run time
Door-closing
F411 torque switching- 0.0%~150.0% rated torque 0.1% 50.0% ☆
point setting
Close door arrival
F412 0.0%~F411 0.1% 30.0% ☆
torque holding
Door-closing
F413 0.0~150.0% 0.1 100.0 ★
blocked torque
0~1
0:stop when blocked in door-
closed blocked
F414 closing 1 1 ★
working mode
1:re-start when blocked in
door-closing
Door-closing
F415 blocked judging 0~9999ms 1ms 500ms ☆
time
Fire emergency
F416 closing high 5.00Hz~F104 0.01Hz 10.00Hz ☆
speed setting
Door-close hi-
F417 F418~F104 0.01Hz 12.00Hz ☆
speed setting
Door-close
F419 blocked low- 0.00Hz~F104 0.01Hz 2.00Hz ☆
speed setting
High-speed
F419 blocked torque 0.0%~150.0% 0.1% 100.0% ☆
setting
Low-spped
F420 blocked torque 0.0%~150.0% 0.1% 100.0% ☆
setting

31
Function parameter table NICE900 User Manual

Function Change
Name Setting range Min.unit default
code properties
F5-open/close door auxiliary parameter
Abnormal
F500 0.1~5.0s 0.1 0.3s ☆
deceleration time

Door open time


F501 0~999.9s 0.1s 0.0s ☆
limit

Door closing time


F502 0~999.9s 0.1s 0.0s ☆
limit

Slow speed run


F503 0~999.9s 0.1s 0.0s ☆
time limit

External open
F504 command delay 0~999.9s 0.1s 0.0s ☆
time

External close
F505 command delay 0~999.9s 0.1s 0.0s ☆
time
0~1
0:straight line acceleration/
Door-open curve
F506 deceleration 1 1 ★
selection
1:S curve acceleration/
deceleration
Open-door 10.0%~50.0%(acceleration/
F507 acceleration S deceleration time)(initial 0.1% 20.0% ★
curve initial time stage+ascend stage≤90%)
Open-door 10.0%~80.0%(acceleration/
F508 acceleration S deceleration time)(initial 0.1% 60.0% ★
curve hoist time stage+ascend stage≤90.0%)
Open-door
10.0%~50.0%(acceleration/
deceleration S
F509 deceleration time)(initial 0.1% 20.0% ★
curve initial stage
stage+ascend stage≤90%)
time

Open-door
10.0%~80.0%(acceleration/
deceleration S
F510 deceleration time)(initial 0.1% 60.0% ★
curve descend
stage+descend stage≤90%)
stage time

0~1
Close door curve 0:straight line
F511 1 1 ★
selection 1:S curve acceleration/
deceleration

32
NICE900 User Manual Function parameter table

Function Change
Name Setting range Min.unit default
code properties
Close door
10.0%~50.0%(acceleration/
acceleration S
F512 deceleration time) initial 0.1% 20.0% ★
curve initial
stage+ascend stage 90%
stage time

close door
10.0%~80.0%(acceleration/
acceleration S
F513 deceleration time)initial 0.1% 60.0% ★
curve ascend
stage+ascend stage 90%
stage time

close door
10.0%~50.0%(acceleration/
deceleration S
F514 deceleration time)initial 0.1% 20.0% ★
curve initial stage
stage+descend stage 90%
time

close door
10.0%~80.0%(acceleration/
deceleration S
F515 deceleration time)initial 0.1% 60.0% ★
curve descend
stage+descend stage 90%
stage time
F516 Speed bias setting 0~80% 1% 50% ☆
Judging time
F517 when the speed 0~5000ms 1ms 400ms ☆
bias is huge
Door-closing
F518 constant speed 0~9999ms 1ms 200ms ★
delay time
F6-distance control parameter
0~1
Door width auto- 0:invalid
F600 tuning function 1:door width measuring,, 1 0 ★
selection valid only in manual adjusting
mode
Door width auto-
F601 0~20.00Hz 0.01Hz 3.00Hz ★
tuning speed

Door width pulse


F602 0~9999 1 0 ★
amount low bit
Door width pulse
F603 0~9999 1 0 ★
amount high bit

Distance control
F604 open startup low 0~30.0% door width 0.0% 15.0% ☆
speed run

33
Function parameter table NICE900 User Manual

Function Change
Name Setting range Min.unit default
code properties
Distance control
open-door
F605 60.0%~90.0%(door width) 0.1% 70.0% ☆
deceleration point
setting

distance control
F606 open-door limit 80.0%~99.0%(door-width) 0.1% 96.0% ☆
point setting

Distance control
close-door startup
F607 0.0%~30.0%(width) 0.1% 10.0% ☆
low speed run
distance
Distance control
close-door
F608 60.0%~90.0%(width) 0.1% 70.0% ☆
deceleration point
setting
Distance control
F609 close-door limit 80.0%~99.0%(width) 0.1% 96.0% ☆
point setting

Low-bit of door-
F611 0~9999 0 0 ★
open limit switch

Low-bit of door-
F612 0~9999 0 0 ★
open limit switch
Swotch position of
F613 0~9999 0 0 ★
the door-closing
Door-width
auto-tuning and
F614 0.0~150.0% 0.1% 80.0% ★
initialation run
torque setting
Pulse low-bit of
F615 the door-open 0~9999 0 0 ★
deceleration point

Pulse high-bit of
F616 the door-open 0~9999 0 0 ★
deceleration point

Pulse low-bit of
F617 the door-closing 0~9999 0 0 ★
deceleration point

Pulse high-bit of
F618 the door-closing 0~9999 0 0 ★
deceleration point

34
NICE900 User Manual Function parameter table

Function Change
Name Setting range Min.unit default
code properties
Door-width setting
F619 when door-open 0~99.9% 0.1% 0 ☆
limit
Door-width setting
F620 when door-closing 0~99.9% 0.1% 0 ☆
limit
F7-Demostrating function parameter
Demonstrate open
F700 arrival holding 1.0~999.9s 0.1s 2.0s ☆
time
Demonstrate
F701 close arrival 1.0~999.9s 0.1s 2.0s ☆
holding time
Demonstrate
F702 close/open times 0~9999 1 0 ★
record.
Demonstrate
F703 open/close specify 0~9999 1 0 ★
run times
F8-auxiliary parameter
Software version
F800 0.00~99.00 0.01 1.00 ●
number
Module
F801 0~100℃ 1℃ 0 ●
temperature
0~100
Error auto reset
F802 0 no auto reset function (gap 1 0 ★
times
is 2s),circulation is 1 hour

Brake utilization
F803 0~100% 1 100 ☆
ratio

Accumulative
F804 0~9999 hours 1 0 ★
working time
F805 reserved(minute) 0 1 0 ★
Accumulative run
F806 0~9999 hours 1 0 ★
time
Reserved (minute
F807 0 1 0 ★
)
Accumulative run
F808 0~9999 hours 1 0 ★
time setting
Accumulative run
F809 0~9999 hours 1 0 ★
time setting

35
Function parameter table NICE900 User Manual

Function Change
Name Setting range Min.unit default
code properties
Error function
F810 0~9999 1 0 ☆
selection
Error function
F811 0~9999 1 0 ★
select
Drive function
F812 0~9999 1 0 ★
select

F814 Overload factor 0~10.00 0.01 1.00 ☆

Door-operator
F816 1~2 1 1 ★
amount
F9-I/O function parameter

terminal
F900 0~100ms 1ms 20ms ☆
filtering time

36
NICE900 User Manual Function parameter table

Function Change
Name Setting range Min.unit default
code properties
0 no function can be
Switch input
F901 re-selected 1 0 ★
terminal DI1
1 open command
2 close command
Switch input
F902 3 external RESET input 1 0 ★
terminal DI2
4 open forbidden
terminal input
Switch input 5 torque holding forbid
F903 1 0 ★
terminal DI3 terminal input
6 low speed open/close
Switch input enable input
F904 1 0 ★
terminal DI4 7 fire input
8~9 reserved
Switch input 10 light curtain N.O input
F905 1 0 ★
terminal DI5 11 touch-pad signal
N.O input
Switch input 12 open limit signal
F906 N.O. input 1 0 ★
terminal DI6
13 close limit signal
N.O. input
Switch input
F907 14 open-door deceleration 1 0 ★
terminal DI7
point N.O input
15 close-door deceleration
point N.O input
16 door lock signal
N.O input
17~109 reserved
110 light curtain N.C input
111 touch pad signal
N.C input
Switch input 112 open limit signal
F908 1 0 ★
terminal DI8 N.C input
113 close limit signal
N.C input
114 open-door deceleration
point N.C input
115 close-door deceleration
N.C input
116 door lock signal
N.C input

37
Function parameter table NICE900 User Manual

Function Change
Name Setting range Min.unit default
code properties
0 no function
Programmable
1 open arrival signal
F909 relay output TA1/ 1 4 ★
output 0
TB1/TC1
2 close arrival signal
output 0
Programmable
3 open arrival signal
F910 relay output TA2/ 1 0 ★
TB2/TC2 output 1
4 close arrival signal
output 1
5 error relay signal
output1
6 reserved
7 open arrival signal
Programmable
output 2
F911 relay output TA3/ 1 3 ★
TB3/TC3 8 close arrival signal
output 2
9 door lock signal output
10 re-open door signal
output
11 blocked signal output
FA-display & error parameter
Adopt binary code =1 select
BIT0 freq. setting Hz
BIT1 run freq. Hz
BIT2 Dc bus voltage V
BIT3 output voltage V
BIT4 output current A
BIT5 output torque %
BIT6 switch input terminal
LED run display state
FA00 parameter BIT7 switch output terminal 1 319 ☆
selection state
BIT8 door width pulse
percentage
Remark: every monitor
amount that selected by FA00
can be displayed
during operation and switched
by SHIFT key.
1~511

38
NICE900 User Manual Function parameter table

Function Change
Name Setting range Min.unit default
code properties
0 open-door setting freq. Hz
1 close-door setting freq. Hz
2 DC bus voltage V
3 switch input terminal state
4 switch output terminal
LED machine-stop state
FA01 display parameter 4 door width pulse percentage 1 39 ☆
selection Remark: every monitor
amount that selected by FA01
can be displayed
during operation and
switched by SHIFT key.
1~63

39
Function parameter table NICE900 User Manual

Function Change
Name Setting range Min.unit default
code properties
FA02 First error type 0 no abnormal record clear 1 0 ●
abnormal record
First error
FA03 1 reserved 1 0 ●
reminding
2 acceleration running
FA04 Second error type over-current Er02 1 0 ●
3 deceleration running
Second error
FA05 over-current Er03 1 0 ●
reminding
4 constant speed running
FA06 Third error type over-current Er04 1 0 ●
5 acceleration running
Third error
FA07 over-voltage Er05 1 0 ●
reminding
6 deceleration running
FA08 4th error type over-voltage Er06 1 0 ●
7 constant speed running
4th error
FA09 over-voltage Er07 1 0 ●
reminding
8~9 reserved
FA10 Last error type 10 controller overload Er10 1 0 ●
11~12 reserved
13 output phase-failure Er13
14 radiator overheated Er14
15 reserved
16 EEPROM read-write
errorsEr16
17 reserved
18 current check circuit
error Er18
19 tuning overtime error Er19
20 speed feedback
error Er20
5th error
FA11 21 initial position check 1 0 ●
reminding
error Er21
22~24 reserved
25 over-speed error Er25
26 parameter setting error
reminding Er26
27 door width auto-tuning
error Er27
28 open overtime Er28
29 close overtime Er29
30 low speed open/close
overtime error Er30

40