Torque Sensor Position Sensor Battery S1 S2 S3 S4: Tap Nominal 50/60Hz W 220/230 X 380/400 Y 400,415/420 Z 440/460 Type 1

The document provides a circuit diagram for a remote control with a power supply. It includes labels for components like transformers, fuses, terminals and sensors. Notes and optional PCBs are referenced on sheet 2.

Uploaded by

mozere mpemba
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
82 views2 pages

Torque Sensor Position Sensor Battery S1 S2 S3 S4: Tap Nominal 50/60Hz W 220/230 X 380/400 Y 400,415/420 Z 440/460 Type 1

The document provides a circuit diagram for a remote control with a power supply. It includes labels for components like transformers, fuses, terminals and sensors. Notes and optional PCBs are referenced on sheet 2.

Uploaded by

mozere mpemba
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

W

CIRCUIT DRAWN WITH POWER SUPPLY OFF FOR TYPICAL REMOTE CONTROL
M 2
2 DETAILS, SEE DOCUMENT
3
3 V
4
1
3
PHASE
RWS100
SUPPLY
U
3 1 TR AN S F OR ME R TAP P IN G OP TION S
6

5 T ap Nominal 50/60Hz
U V W E TYP E 1
FS1
W 220/230
X 380/400
C1 C2 Y 400,415/420
U W X Y Z
Z 440/460
F US E F S 1= 250mA A NTI-S UR G E
SK2 TYP E 2
0VAC 1 W 346/380
TRANSISTOR SWITCHING FOR
PS1 X 480/500
24VDC CONTACTORS (IQ10-35) 120VAC 4
RELAYS ONLY FITTED WHEN Y 240/240
0VDC
120VAC CONTACTOR IS FITTED 3 4 Z 550/575
24VDC
FOR IQ40,70,90,91 & 95 24VDC 6 F US E F S 1= 250mA A NTI-S UR G E
_ 5 NOMINAL SUPPLY

+
(OUTPUT)
TYP E 3
SK14
X 660/660-690
0VDC 1
INTERNAL SUPPLY Y 690/-
24VDC FOR AUX POWER PCB F US E F S 1= 150mA A NTI-S UR G E
2
SK13

26 WAY
REFER TO SHEET 2 FOR NOTES
& OPTION PCB'S IF FITTED

SK3 SK13 SK14


6 1 42
MONITOR RELAY
5 3 43
TORQUE 4 2 44
3
2
SK7
SENSOR 1 1 6
SK8 MAKE AT FULLY SHUT S1 8 7
POSITION 10 WAY 2 8
SENSOR MAKE AT FULLY OPEN S2 7 9
SK9 BREAK AT FULLY SHUT
3 10
BATTERY - 4
S3 6 11
4 12
+
1 BREAK AT FULLY OPEN S4 5 13
FS2 (IF FITTED) 100mA SK4
CLOSE 9 33
STOP/ MAINTAIN 10 34
50% SK6 OPEN 8 35
COMMON -VE 1 36
18 WAY
STOP
ESD 12 25
CLOSE
LOCAL

OPEN
REMOTE OPEN INTERLOCK 13 37
CLOSE INTERLOCK 14 38
COMMON -VE 5 31
SK1 SK2
SLOT A SLOT B
SK1
SLOT C

Iss Date Chkd Revision Details IQ + CPT + AUX POWER + EXTRA RELAYS S5-S8
1 221013 JC1 First issue. www. .com
2 180214 PJW MI REF REMOVED ROTORK CONTROLS LTD ROTORK CONTROLS INC Drawn by: PJW Circuit Diagram Number Issue Sheet
3 160614 MR 400v added to type 1 BATH, BA1 3JQ ROCHESTER Date : 221013 No
tapping Y. Note added to
sheet 2 note 1.
ENGLAND NY 14624, USA
Base WD: 101B1010
Job No : - -
101B1010 3
1
of 2
Tel:01225-733200 Tel:585-247-2304 MI No : - B1 C1 B2 C2 B1 C1M1V1
IQ3
CIRCUIT DRAWN WITH POWER SUPPLY OFF

SLOT A
SK1
SLOT A SK3
-VE +VE
1 23 A
2 22
3
4
5
CPT

NOT USED 6 FOR DETAILS OF CPT FUNCTIONS


REFER TO ROTORK PUBLICATION PUB002-041
7
8

SK6
1 0V SUPPLY FROM SK5 ON AUX POWER PCB
2 24V
SK8
1
2

SLOT B
SK2
SLOT B SK3
EXTRA CHANGE OVER CONTACTS

2 14
FOR OTHER SETTINGS SEE PUB002-038

S5 3
MAKE AT FULLY SHUT 16
DEFAULT SETTINGS SHOWN

1 15
5 17
MAKE AT FULLY OPEN S6 6 19
4 18
8 20
MAKE ON TORQUE
TRIP S7 9 24
7 21
11 30
MAKE WHEN REMOTE
S8 12
SELECTED 47
10 46

SLOT C
SK1
SLOT C
SK3
1 0V
2 24V SUPPLY FROM SK14 ON POWER PCB
POWER

DC/DC
CONVERTER SK5
AUX

1 0V
2 24V SUPPLY TO SK6 ON CPT PCB
SK4
+ve
1 32 EXTERNAL 17-34VDC CUSTOMER SUPPLY FOR FOLO/CPT
-ve
4 40

NOTES
1.FUSES:
-PS1 is a self-resetting fuse. 3.INDICATION:
-Refer to publication PUB002-039 for approved fuses FS1 and FS2. -For typical position, status and alarm indication see PUB002-041.
-Actuator rated voltage specified on nameplate. Voltage tolerance +/-10%, -“S” contacts are user configurable and are shown in their default
applies for rated torque performance; duty cycle is not guaranteed. setting.
2.REMOTE CONTROL: -Refer to PUB002-040 for functions and configuration instructions.
-For typical remote control circuits refer to: -Monitor Relay indicates actuator availability for remote control (shown
-RWS indicated or PUB002-041. “unavailable”). It can be configured to exclude local/remote selection.
-For DC and AC control, connect –ve/0V to terminal 36. -Refer to PUB002-040 for monitored functions and configuration
-(For negative switch / positive common, refer to RWS indicated). instructions.
-Control signal threshold voltages: -Voltage applied to indication contacts must not exceed 150Vac
-DC: “on” ≥16Vdc / “off” ≤8Vdc, max 60Vdc. -Individual Switch current must not exceed 3.5A inductive, 5A resistive
-AC: “on” ≥60Vac / “off” ≤40Vac, max 120Vac. and no more than 8A in total for all 4 contacts.
-Control signal duration to be 300ms minimum.
-Maximum current drawn from remote control signals is: 4.BATTERY:
-8mA at 24Vdc or 12mA at 120Vac. -Battery maintains local and remote “S” contact indication only.
-Supply provided on terminals 4 & 5: -Refer to installation manual for approved replacement battery types.
-Intended for remote control. Circuit Diagram Number Issue Sheet
-Max external load 5W at 24Vdc / 5VA at 120Vac No
2
See Sheet 1 for all Revision details/information 101B1010 3 of 2
IQ3