CEHA
CEHA
Technical data
Application Construction
The Sterling SIHI CEH pump is a self-priming side channel Casing pressure
pump capable of handling gas along with the medium and
operates at a low noise level. Maximum 40 bar from -40 °C up to +120 °C.
The CEH pumps are used for problem-free pumping of clean Maximum 32 bar from +120 °C up to +180 °C.
liquids at unfavourable suction side conditions. They are also Pressure stages for temperature as per DIN EN 1333.
very suitable for positive suction heads below 0.5m
Please observe
The different material possibilities with uniform dimensions Technical rules and safety regulations:
and performance characteristics as well as the standard Casing pressure = inlet pressure + delivery head at minimum
exchangeable components, make the CEH particularly pump capacity.
recommendable for applications in the pharmaceutical,
chemical or petrochemical market as well as in the plastic or
oil industry. Because of its low NPSH and positive suction Position of branches
head the CEH is very suitable for the pumping of liquefied Axial suction branch, discharge branch points radially upwards
gasses and liquids under vapour pressure like condensate,
refrigerant, boiler feed water or LPG.
Flanges
The pumps of the CEH /7 series have a retaining stage to
avoid the dry running by controlling the liquid level in the pump. The flanges correspond to DIN EN 1092-2 / PN 40.
This design is especially developed for the handling of liquids Flange design as per DIN 2512 with groove or drilled according
under vapour pressure or when pumping from underground to ANSI 150 or 300 lbs is basically possible.
tanks. The series CEH /5 are used for bottom off-loading of
liquids under vapour pressure.
Bearing
Design One grease lubricated ball bearing according to DIN 625 and
one liquid surrounded sleeve bearing (design A). The ball
bearing is greased for life.
Pumps of the series CEH have a segmental type construction
with open vane wheel impellers. The construction of the CEH
pump is a so-called centrifugal combined system. Direction of rotation
This combination pump is suited with a centrifugal stage in
serial connection before the side channel stages to obtain a Anti-clockwise, when looking from the drive end.
more favourable NPSH.
The program comprises 6 sizes each with 1-8 stages. The Shaft sealing
existing material design allows an optimum rating for the The shaft can be sealed by a stuffing box or a mechanical
respectively desired performance range and the pumping seal conform DIN EN 12756.
medium. The shaft sealing is also available in a design suitable for
heating or cooling of the stuffing box or the mechanical seal.
Pumps of the series CEH /7 are equal to the CEH series but
equipped with a retaining stage. This program comprises 6 Double mechanical seal (back-to-back as well as tandem) or
sizes with 2-7 stages. The series CEH /5 have also 6 sizes a quench design with throttle bush are available upon request.
but with 2-8 stages. The CEH can also be supplied with a magnetic coupling (for
information see the separate catalogue).
The applied hydraulic components are from our Modular Side
Channel system (interchangeability of parts).
2350 Vane wheel impeller CuZn40Al2 G-X 3 CrNiMoCuN 26 6 3 3 PAEK CuZn40Al2 G-X 3 CrNiMoCuN 26 6 3 3 PAEK
* Bearing bush in Carbon Antimony is used only in the high temperature design. This high temperature design is also provided
with cup springs and a cooled stuffing box or cooled mechanical seal.
Stainless steel
4410
4330
1081
The CEH pump or so-called centrifugal combined system (combination pump) is suited with a low NPSH centrifugal impeller
before the side channel stages (series connection). This NPSH inducer stage creates enough pressure to overcome the
entrance pressure loss of the first side channel stage or NPSH required.
Impeller
The turning of the vane wheel impeller creates an under pressure at the beginning of the side channel (centrifugal effect) and the
gas or liquid with gas is drawn in. The air displacement channel provokes a positive displacement effect so the gas remaining
at the root of the vane wheel impeller is forced out through the gas slot.
The pressure generating is obtained by the repetitive re-entering of the liquid in the side channel (corkscrew movement).
Side Channel
Gas
A side channel pump can de-aerate and degas the suction line by itself and is thus very suitable for suction lift operation. A side
channel pump can handle large quantities of (entrained) gas. Mixtures up to a gas share of 50% are possible. The ability for self-
priming and the handling of large amounts of (entrained) gas, will guarantee continuous operation even in case of evaporation
and therefore contribute to a higher level of safety in industrial processes.
To avoid cavitation the distance between the liquid level and the entrance at the suction side of the pump is restricted. This
distance is related to the NPSH or Net Positive Suction Head. The NPSH for CEH pumps is very low due to it special construction.
The axial entrance and its larger diameter results in a less disturbed flow and lower friction losses. Together with the low NPSH
of the centrifugal impeller the CEH can handle a positive suction head of less than 0.5 m.
This makes the CEH very suitable for pumping liquids near their boiling point at reasonable economic expenses and the low
NPSH guarantees also full output capacity because of operation without cavitation.
General conditions
Liquid: Water
Density: 1 kg/dm3
Viscosity: 1 cSt
Temperature: 20 °C
Atmospheric pressure: 1013 mbar
Characteristic tolerances
Capacity ± 5% - Delivery head ± 5% - Power + 10%
For designs with a mechanical seal or a casing seal of soft Teflon, the tolerance for the delivery head is extended by 2% each.
Measuring standard
According to ISO 5198
300
200
100
0 0,4 1 2 4 6 8 10 20 Q 40
(m3/h)
NPSH
(m)
0,8 6100
0,6 5100
0,4 4100
3100 3600
0,2 1200
0 0,4 1 2 4 6 8 10 20 Q 40
(m3/h)
The NPSH curve is suitable for liquids without gas. When using a liquid containing gas (e.g. water 20 °C) a safety margin
of 1 m has to be added.
12 w
200 08 1450 rpm
12 a 171
07 25
H 12
06 4
(m)
120
5
120
100 4
1203
1202
G¼
1201 1)
44 41
0 m2 113
m1
3 v e1
12
08 f1
P 120
(kW) 7 w1
120
2 6
120 ∅14x4
5
1204 ∅105
∅75
1203 DN20
1 ∅14j5
1202
100 5
1201 1) ∅150
∅110
0 DN40
∅18x4
NPSH3) h3 176 10 100 16,1
(m)
0,6 d
0,4 35 13
0,2 105
0 140 c
0 1 2 Q 3 e2
(m3/h) b2
General: Values are valid for water ρ = 1 kg/dm3 and ν = 1 cSt. * Dimensions depend upon the motor brand.
1)
Not for design CEH /5.
Design tolerances: Capacity ± 5% - Delivery head ± 5% - Power + 10%. 2)
For EExe II T3 motors.
For designs with a mechanical seal or casing seal of soft Teflon, 3)
A safety margin of 1 m has to be added
the tolerance for the delivery head is extended by 2% each. when using a liquid containing gas.
The weight of the pump will be approximately 6% higher when using Stainless steel.
w
31 1450 rpm
300 08 201
a
31
07 40
H
(m) 310
6 4
310
200 5
310
4
3103
100 3102 G¼
3101 1)
50 42
m2 134
0 m1
P v e1
(kW) 310 f1
8
7 310 w1
7
6 310
6
310 ∅18x4
5 5 ∅140
4 3104 ∅100
3103 DN32
3 ∅19j5
3102 132
2 ∅185 6
31011) ∅145
1
DN65
0
NPSH3) h3 214 12 112 21,5
∅18x8
(m) d
35 13
0,2
135
0 170 c
1 2 3 4 Q 5 e2
(m3/h) b2
General: Values are valid for water ρ = 1 kg/dm3 and ν = 1 cSt. * Dimensions depend upon the motor brand.
1)
Not for design CEH /5.
Design tolerances: Capacity ± 5% - Delivery head ± 5% - Power + 10%. 2)
For EExe II T3 motors.
For designs with a mechanical seal or casing seal of soft Teflon, 3)
A safety margin of 1 m has to be added
the tolerance for the delivery head is extended by 2% each. when using a liquid containing gas.
The weight of the pump will be approximately 6% higher when using Stainless steel.
1 36011) DN65
General: Values are valid for water ρ = 1 kg/dm3 and ν = 1 cSt. * Dimensions depend upon the motor brand.
1)
Not for design CEH /5.
Design tolerances: Capacity ± 5% - Delivery head ± 5% - Power + 10%. 2)
For EExe II T3 motors.
For designs with a mechanical seal or casing seal of soft Teflon, 3)
A safety margin of 1 m has to be added
the tolerance for the delivery head is extended by 2% each. when using a liquid containing gas.
The weight of the pump will be approximately 6% higher when using Stainless steel.
4102 G¼
41011) 52 43
m2 140
0 m1
P v e1
410 f1
(kW) 8
12 410 w1
7
410
10 6 ∅18x4
410 ∅150
8 5
∅110
4104 DN40
∅24j5
6 4103 140 8
∅200
4 4102 ∅160
41011) DN80
2
h3 238 15 132 26,9
NPSH3) ∅18x8
(m) d
0,5 40 13
155
195 c
0 e2
6 7 8 9 10 11 12
Q
13 b2
(m3/h)
General: Values are valid for water ρ = 1 kg/dm3 and ν = 1 cSt. * Dimensions depend upon the motor brand.
1)
Not for design CEH /5.
Design tolerances: Capacity ± 5% - Delivery head ± 5% - Power + 10%. 2)
For EExe II T3 motors.
For designs with a mechanical seal or casing seal of soft Teflon, 3)
A safety margin of 1 m has to be added
the tolerance for the delivery head is extended by 2% each. when using a liquid containing gas.
The weight of the pump will be approximately 6% higher when using Stainless steel.
510 w
300 8 1450 rpm
510 a 237
H 7
(m) 50
510
6 4
200 5105
5104
5103
100 5102 G¼
60 66
5101 1)
m2 159
0 m1
v e1
510 f1
30 8
P 510 w1
7
(kW)
5106
∅18x4
20 5105 ∅165
∅125
5104
DN50 ∅24j5
5103
165
10 ∅235 8
5102
∅190
51011)
DN100
h3 276 18 160 30,9
NPSH3) ∅22x8
(m) d
0,5 45 15
170
0 215 c
10 12 14 16 18 Q 20 e2
(m3/h) b2
General: Values are valid for water ρ = 1 kg/dm3 and ν = 1 cSt. * Dimensions depend upon the motor brand.
1)
Not for design CEH /5.
Design tolerances: Capacity ± 5% - Delivery head ± 5% - Power + 10%. 2)
For EExe II T3 motors.
For designs with a mechanical seal or casing seal of soft Teflon, 3)
A safety margin of 1 m has to be added
the tolerance for the delivery head is extended by 2% each. when using a liquid containing gas.
The weight of the pump will be approximately 6% higher when using Stainless steel.
0 DN100
NPSH3) h3 300 20 180 35,3
(m) ∅22x8
d
0,5 50 15
195
0 245
15 20 25 30 Q 35 c
e2
(m3/h) b2
General: Values are valid for water ρ = 1 kg/dm3 and ν = 1 cSt. * Dimensions depend upon the motor brand.
1)
Not for design CEH /5.
Design tolerances: Capacity ± 5% - Delivery head ± 5% - Power + 10%. 2)
For EExe II T3 motors.
For designs with a mechanical seal or casing seal of soft Teflon, 3)
A safety margin of 1 m has to be added
the tolerance for the delivery head is extended by 2% each. when using a liquid containing gas.
The weight of the pump will be approximately 6% higher when using Stainless steel.
w
200 1450 rpm
12 a 171
07
25
H 12 G½
06 4
(m)
120
5
120
100 4
1203
1202
G¼
44 41
0
m2 113
m1
3 v e1
12 f1
P 07
(kW) 120 w1
6
2 120
5 ∅14x4
1204 ∅105
∅75
1203
DN20
1202 ∅14j5
1 100
∅150 5
∅110
0 DN40
∅18x4
h3 176 10 100 16,1
NPSH1)
(m) d
0,4 35 13
0,2 105
0 140
0 c
1 2 Q 3 e2
(m3/h) b2
1)
A safety margin of 1 m has to be added when using a liquid containing gas.
* Dimensions depend upon the motor brand.
w
31 1450 rpm
300 07 a 201
H 310 40
(m) 6 G½
310 4
5
200 310
4
3103
3102
100
G¼
50 42
0
m2 134
m1
P
(kW) 31 v e1
07
f1
6 31
06 w1
5 310
5
3104 ∅18x4
4
∅140
3103 ∅100
3 DN32
3102 ∅19j5
2 132
∅185 6
1 ∅145
0 DN65
∅18x8 12 112 21,5
h3 214
NPSH1)
(m) d
35 13
0,2
135
0 170
1 2 3 4 5 c
Q e2
(m3/h) b2
1)
A safety margin of 1 m has to be added when using a liquid containing gas.
* Dimensions depend upon the motor brand.
H w
(m) 1450 rpm
200 36 a 237
07
50
36 G½
06
4
360
5
360
4
100 3603
3602
G¼
50 42
0 m2 134
P m1
(kW) v e1
7 36 f1
07
6 360 w1
6
5 360
5 ∅18x4
4 3604 ∅140
∅100
3603 DN32
3
∅19j5
3602 132
2 ∅185 6
∅145
1
DN65
NPSH 1)
∅18x8 12 112 21,5
h3 214
(m)
0,5 d
35 13
0 135
3 4 5 6 7
Q
8 170 c
e2
(m3/h)
b2
1)
A safety margin of 1 m has to be added when using a liquid containing gas.
* Dimensions depend upon the motor brand.
H w
(m) 1450 rpm
41 a 195
07
200 410 45
6 G½
410 4
5
410
4
100 4103
4102
G¼
52 43
0 m2 140
m1
P v e1
12 410
7 f1
(kW)
410 w1
10 6
410
5
8 ∅18x4
4104
∅150
∅110
6 4103 DN40
∅24j5
4102 140
4 ∅200 8
∅160
2
DN80
NPSH1) ∅18x8 15 132 26,9
h3 238
(m)
d
0,5
40 13
0 155
6 7 8 9 10 11 12 Q 13 195 c
e2
(m3/h)
b2
1)
A safety margin of 1 m has to be added when using a liquid containing gas.
* Dimensions depend upon the motor brand.
w
300 510 1450 rpm
7
a 237
H 510
6 50
(m) G½
5105 4
200
5104
5103
5102
100
G¼
60 66
0
m2 159
30 m1
510 v e1
P 7
f1
(kW) 5106
w1
20 5105
5104 ∅18x4
∅165
5103 ∅125
DN50
10 ∅24j5
5102
165 8
∅235
∅190
DN100
NPSH1) ∅22x8 18
h3 276 160 30,9
(m)
0,5 d
45 15
0 170
10 12 14 16 18 20
Q 195 c
(m3/h) 215
b2
1)
A safety margin of 1 m has to be added when using a liquid containing gas.
* Dimensions depend upon the motor brand.
H w
(m) 61
07 1450 rpm
300 a 262
610
6 65
G½
610
5
200 610
4
6103
100 6102
G3/8
64 63
0
m2 172
P
(kW) m1
50 610 v e1
7
f1
610
40 6 w1
6105
30 6104
∅18x4
∅185
6103 ∅145
20
6102 DN65
∅32j5
10 180
∅235 10
∅190
0
DN100
NPSH1) ∅22x8 180 35,3
(m) h3 300 20
0,5 d
50 15
0
15 20 25 30 35 195
Q 245 c
(m3/h) e2
b2
1)
A safety margin of 1 m has to be added when using a liquid containing gas.
* Dimensions depend upon the motor brand.
It is the policy of Sterling Fluid Systems to seek continually for ways to improve its products
and the right is reserved to alter specifications at anytime without prior notice.
Sterling Fluid Systems offers an extensive Side Channel pump range under its brand name Sterling
SIHI. Sterling Fluid Systems has more than 80 years of experience in manufacturing, installation and
support of Side Channel pumps. The Sterling SIHI Side Channel pumps can be found in a wide
application range for the:
• Chemical market
• Pharmaceutical industry
• Petrochemical industry
• Food industry
• Ship yards
• LPG industry
• and many more ...
CEH
AEH
AEHL
ADHL
100 CDHL
Delivery head (m)
AOH ASH
AKH
10 AKL
AKV
AOL
DRV
0 10 20 30 40
Capacity (m3/h)
The Sterling SIHI Side Channel pumps comply with the highest demands of our customers and
are the best solution for the handling of liquids under critical physical conditions.
Sterling Fluid Systems (Austria) Sterling Fluid Systems (Belgium) Sterling Fluid Systems (Czech R epublic)
Republic)
A-1100 Wien, Zone Gosset, t Hofveld 1, Kosmonautu 8,
Oberlaaer Strasse 228, Austria. B-1702 Groot-Bijgaarden, Belgium. CZ-77211 Olomouc, Czech Republic.
Telephone : +43 (0)1 680 050 Telephone : +32 (0)2 481 7711 Telephone : +420 (0)68 551 66 51
Fax : +43 (0)1 680 0521 Fax : +32 (0)2 481 7737 Fax : +420 (0)68 551 66 53
Sterling Fluid Systems (France) Sterling Fluid Systems (Germany) Sterling Fluid Systems (Germany)
Zone Industrielle de Trappes-Elancourt, Lindenstrasse 170 Halbergstrasse 1
1-3, Avenue Georges Politzer B.P. 41, D-25524 Itzehoe/Holstein, Germany. 67061 Ludwigshafen, Germany.
78193 Trappes Cedex, France. Telephone : +49 (0)4821 77101 Telephone : +49 (0)621 56 12 0
Telephone : +33 (0)1 34 82 39 00 Fax : +49 (0)4821 771213 Fax : +49 (0)621 56 12 205
Fax : +33 (0)1 34 82 39 61
Sterling Fluid Systems (Hellas) Sterling Fluid Systems (Hungary) Sterling Fluid Systems (Italy)
4, Clisouras Street, Radnóti Ter 2/A, Via Pompei, 15
GR-176 72 Kallithea, Athens, Greece. H-8200 Veszprém, Hungary. I-20052 Monza,Italy.
Telephone : +30 (0)1 9570783 Telephone : +38 (0)88 40 63 33 Telephone : +39 (0)39 2824 1
Fax : +30 (0)1 9568121 Fax : +38 (0)88 40 66 35 Fax : +39 (0)39 2824 2 20
Sterling Fluid Systems (Netherlands) Sterling Fluid Systems (Polska) Sterling Fluid Systems (R omania)
(Romania)
Havenstraat 22-28, Postbus 27 UI, Chocimska 28 Mihai Eminescu 105 - 107,
NL 1940 AA Beverwijk, PL-00-791, Warzawa RO-72112, Bucarest 2.
The Netherlands. Telephone : +48 (0) 22 849 7097 Telephone : +40 (0) 1 610 7188
Telephone : +31 (0)251 263 232 Fax : +48 (0) 22 849 6726 Fax : +40 (0) 1 210 8287
Fax : +31 (0)251 226 309
Sterling Fluid Systems (USA) Sterling Fluid Systems (Canada) Sterling Fluid Systems (USA)
303 Industrial Boulevard, 225 Speedvale Avenue West, 2005 Dr M. L. King Jr. Street,
P O Box 460, P O Box 728. P O Box 7026,
Grand Island, NY 14072-0460, USA. Guelph, Ontario N1H 6L8, Canada. Indianapolis, IN 46207-7026, USA.
Telephone : (1) 716 773 6450 Telephone : (1) 519 824 4600 Telephone : (1) 317 925 9661
Fax : (1)716 773 2330 Fax : (1) 519 824 7250 Fax : (1) 317 924 7388
Sterling Fluid Systems (Asia) SIHI (Australia) Sterling Fluid Systems (China)
37 Tech Park Crescent, 820 Mountain Highway, Room 6016, 6th Floor, Central Place
Tuas South Avenue 4, Bayswater, Victoria 3153, No 16 Henan Road South,
Singapore 637851. Australia. Shangai 200002, China
Telephone : (65) 8630 828 Telephone : (61) 3 9720 1500 Telephone : (8621) 63363488 /(8621) 63740220
Fax : (65) 8630 868 Fax : (61) 3 9720 4076 Fax : (8621) 63268487
Sterling Fluid Systems (Malaysia) Sterling Fluid Systems (Philippines) Sterling Fluid Systems (Thailand)
No. 2, Jalan TPK 2/2, Taman Suite 404 & 405, Alabang Corporate 1st Floor, Solid Group Building,
Perindustrian Centre, 104 Thavorn, Patanakarn Road,
Kinrara, Section 2, 47100 Puchong, Km. 25 West Service Road, Suan-Luang,
Selangor Darul Ehsan, Malaysia. South Superhighway, Bangkok 10250, Thailand.
Telephone : (60) 3 5700198/99 Muntinlupa City, Philippines. Telephone : (66) 2 321 8422/3
Fax : (60) 3 5700204 Telephone : (63) 2 807 2076 Fax : (66) 2 321 8413
Fax : (63) 2 807 2013
Sterling Fluid Systems (Middle East) Sterling Berk efeld (Middle East)
Berkefeld Sterling Fluid Systems (South Africa)
P O Box 61491, Jebel Ali, Dubai U.A.E. P O Box 71421, Dubai U.A.E. 8483 Edleen, 1625 Johannesburg, R.S.A.
Telephone : +971 (0)4 8838 733 Telephone : +971 (0)4 3323 773 Téléphone : (27) 11 394 3922
Fax : +971 (0)4 8838 735 Fax : +971 (0)4 3323 737 Fax : (27) 11 970 2472
www.sterlingfluidsystems.com