Mixer
Mixer
Address:
P.O. box 124 Blindern
NO-0314 Oslo
Test report
Norway
Visit address:
Børrestuveien 3
Oslo Testing of Kitchen mixers from Akvatur IVS, type
Taurus.3-1, 4-1 and 5-1
Test method NS-EN 817:2008
The tests have carried out in accordance with NS-EN 817:2008 ” Sanitary tapware –
Mechanical mixing valves (PN 10) - General technical specification”.
Result: Passed
Project leader/writer:
Geir Lippe Stavnes ______________________________
Controlled by:
Karolina Stråby ______________________________
Approved by:
Lars-Erik Fiskum ______________________________
Report no.: Classification
202000453 Restricted
The test results only apply to objects that have been tested.
The report belongs to the client and cannot be given to a third party without the client’s permission.
The report can only be copied in its entirety unless SINTEF has given specific consent.
202000453 1 of 11
1. INTRODUCTION
SINTEF Community has on behalf of Akvatur IVS, carried out testing of kitchen mixers, type Taurus 3-1,
4-1 and 5-1. Leaktightness testing of an additional water cooler was also carried out.
The tests according to NS-EN 817 were conducted by Geir Lippe Stavnes (Research engineer). The tests
were carried out in the Sanitary lab. (U47) between 14/4-2020 and 12/5-2020.
Evaluations of impartiality have been performed in all steps of the testing process, and impartiality has
been found to be in accordance with SINTEF's quality management system and the current standard for
the activity.
2. TEST METHOD
The tests have been carried out in accordance with NS-EN 817:2008 ” Sanitary tapware – Mechanical
mixing valves (PN 10) - General technical specification”.
3. TEST OBJECT
The test objects from Akvatur IVS are kitchen mixers, see Figure 3.1-3.3. All models are designed to be
used with additional parts such as filters, coolers, and/or heaters. Only the water cooler unit (Fig. 3.4)
was delivered to SINTEF in addition to the test objects. Leaktightness testing of the cooler was
performed as a supplement to the testing of the mixer taps.
The mixers were delivered with flexible hoses from Neoperl and Tucai.
The mixers are produced by Eloira Sanitaryware Co.,Ltd. and they were delivered to SINTEF Community
on 14.4.2020. They were selected by the customer and in good condition on arrival.
The test results only apply to objects that have been tested.
The report belongs to the client and cannot be given to a third party without the client’s permission.
The report can only be copied in its entirety unless SINTEF has given specific consent.
202000453 2 of 11
Fig. 3.1: Taurus 3-1 Fig. 3.2: Taurus 4-1
The test results only apply to objects that have been tested.
The report belongs to the client and cannot be given to a third party without the client’s permission.
The report can only be copied in its entirety unless SINTEF has given specific consent.
202000453 3 of 11
4. TESTS, METHODS, REQUIREMENTS AND RESULTS
1) Not applicable
2) Not considered
The test results only apply to objects that have been tested.
The report belongs to the client and cannot be given to a third party without the client’s permission.
The report can only be copied in its entirety unless SINTEF has given specific consent.
202000453 4 of 11
4.1 Marking (NS-EN 817, Clause 4.1)
Method: Visual inspection
Remark: The mixers are marked with a "drop" logo for Akvatur IVS
The test results only apply to objects that have been tested.
The report belongs to the client and cannot be given to a third party without the client’s permission.
The report can only be copied in its entirety unless SINTEF has given specific consent.
202000453 5 of 11
4.6 Leaktightness of the mixing valve upstream of the obturator
(NS-EN 817, Clause 8.3)
Method: Outlet orifice open and the obturator closed
The test results only apply to objects that have been tested.
The report belongs to the client and cannot be given to a third party without the client’s permission.
The report can only be copied in its entirety unless SINTEF has given specific consent.
202000453 6 of 11
4.10 Leaktightness of the obturator: cross flow between hot water and cold water
(NS-EN 817, Clause 8.7)
Method: Outlet orifice open and the obturator closed
4.11 Mechanical behaviour upstream of the obturator (NS-EN 817, Clause 9.4)
Method: Outlet orifice open and the obturator closed
Remark 1): The mixer is not leak tight above 19 bar, but no deformation is registered.
4.12 Mechanical behaviour downstream of the obturator (NS-EN 817, Clause 9.5)
Method: Outlet orifice open and the obturator open
The test results only apply to objects that have been tested.
The report belongs to the client and cannot be given to a third party without the client’s permission.
The report can only be copied in its entirety unless SINTEF has given specific consent.
202000453 7 of 11
4.13 Determination of flow rate (NS-EN 817, Clause 10.6)
Method: Measuring the flow rate at 0,3 MPa
Remark: The flow rate measured at 0,3 MPa shall be at least 0,15 l/s from fully open cold water
to fully open hot water when the tap is delivered with flexible supply hoses.
According to EN 817:2008, a flow rate of 0,06 l/s is permissible for water saving mixers.
See Table 4.2 for results.
Measurement uncertainty ± 2 %
Remark: The test was carried out with the factory installed aerator
The test results only apply to objects that have been tested.
The report belongs to the client and cannot be given to a third party without the client’s permission.
The report can only be copied in its entirety unless SINTEF has given specific consent.
202000453 8 of 11
4.14 Sensitivity (NS-EN 817, Clause 10.7)
Method: Measuring the sensitivity at 0,3 MPa
Torque Result
Mixer
(Nm) Passed Not passed
Taurus 3-1 6 x
Taurus 4-1 6 x
Taurus 5-1 6 x
4.16 Mechanical endurance of the control device (NS-EN 817, Clause 12.1)
Method: Subjecting the control device to a specific number of movements
Result
Mixer Movements
Passed Not passed
Taurus 3-1 70 000 x
Taurus 4-1 70 000 x
Taurus 5-1 70 000 x
The test results only apply to objects that have been tested.
The report belongs to the client and cannot be given to a third party without the client’s permission.
The report can only be copied in its entirety unless SINTEF has given specific consent.
202000453 9 of 11
4.17 Mechanical endurance of diverters (NS-EN 817, Clause 12.2)
Method: Subjecting the diverter to a specific number of movements
Result
Mixer Movements
Passed Not passed
Taurus 3-1 30 000 x
Taurus 4-1 30 000 x
Taurus 5-1 30 000 x
Result
Mixer Movements
Passed Not passed
Taurus 3-1 80 000 x
Taurus 4-1 80 000 -1)
Taurus 5-1 80 000 x
Remark 1): The mixer has a pull-out spout, hence there is no water pressure on the swivel joint.
Result
Mixer
Passed Not passed
Taurus 3-1 x1)
Taurus 4-1 x2)
Taurus 5-1 x1)
Remark 1: There is an airgap between the outlet and the highest level of sink
Remark 2: The mixers are equipped with a check valve on the outlet. The valve itself is not
tested by SINTEF Community
The test results only apply to objects that have been tested.
The report belongs to the client and cannot be given to a third party without the client’s permission.
The report can only be copied in its entirety unless SINTEF has given specific consent.
202000453 10 of 11
4.20 Acoustic characteristics (NS-EN 817, clause 14)
Method: EN ISO 3822
Measurement uncertainty ± 3 dB
Remark: The acoustic test was carried out with the factory installed aerator
Result
Mixer
Weight (Grams)
Taurus 3-1 1680 2)
Taurus 4-1 2700 1)
Taurus 5-1 2007 2)
Oslo, 14.05.2020
SINTEF Community
The test results only apply to objects that have been tested.
The report belongs to the client and cannot be given to a third party without the client’s permission.
The report can only be copied in its entirety unless SINTEF has given specific consent.
202000453 11 of 11
50
SINTEF Community
45
Tm+4 = 42
Temperature [°C] - Measurement uncertainty +/- 0,5 ℃
40
35
Tm-4=34
30 Taurus 3-1
Sensitivity
25
20
Page 1
Appendix 1
From cold to hot
From hot to cold
15
10
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140
Movement control device [mm]
60
SINTEF Community
55
50
Temperature [°C] - Measurement uncertainty +/- 0,5 ℃
45
Tm+4 = 42
40
35 Taurus 4-1
Tm-4=34 Sensitivity
30
25
Page 2
Appendix 1
20 From cold to hot
From hot to cold
15
10
0 10 20 30 40 50 60 70 80 90 100 110
Movement control device [mm]
50
SINTEF Community
45
Tm+4 = 42
Temperature [°C] - Measurement uncertainty +/- 0,5 ℃
40
35
Tm-4=34
30 Taurus 5-1
Sensitivity
25
20
Page 3
Appendix 1
From cold to hot
From hot to cold
15
10
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140
Movement control device [mm]
Appendix 2
SINTEF Community