PRODUCT DATA SHEET

SikaTop®-550 Seal
(formerly MasterSeal® 550)

Acrylic cementitious waterproofing coating

DESCRIPTION ▪ As a backing to marble and granite to prevent water


ingress and thus alleviate surface staining.
SikaTop®-550 Seal is a two-component acrylic modi- ▪ To provide protection to concrete surfaces from car-
fied cementitious coating that requires on site mixing bonation and chloride attack.
▪ To provide foundation protection.
to form product to waterproof and resurface concrete,
▪ For waterproofing of wet areas under tiling.
masonry, and most other construction materials.
Can be applied by stiff brush, roller, or trowel, it forms
a waterproof coating. FEATURES
SikaTop®-550 Seal provides an effective barrier to wa-
terborne salts and atmospheric gases. ▪ Easy to apply by brush or in thin trowel applications
Fluid applied, SikaTop®-550 Seal provides a hard wear- ▪ No additional water required
ing, seamless, waterproof membrane. ▪ Excellent adhesion to various substrates
SikaTop®-550 Seal is composed of specially selected ▪ Suitable for contact with potable water
cements, silica sand and reactive fillers supplied in ▪ Breathable - whilst repelling water, allows substrate
powder form together with a liquid component of to breathe
blended acrylic copolymers and wetting agents. ▪ High resistance to chloride ion diffusion
Suitable for use in hot and tropical climatic conditions. ▪ Unlike conventional coatings which require a 7-28
day cure of concrete, SikaTop®-550 Seal can be ap-
plied to 24 hour-old concrete thereby giving immedi-
USES ate protection
▪ As a waterproof lining for water retaining structures.
▪ For coating seawater channels. CERTIFICATES AND TEST REPORTS
▪ For waterproofing and protection against brackish
▪ BS 6920: Part 1 2000 - Suitable for use in contact
water.
with potable water.
▪ SikaTop®-550 Seal is certified according "Low Emit-
ting Materials as per Al Sa'fat - Dubai Green Building
Evaluation System" by Dubai Central Laboratory
(DCL)

PRODUCT INFORMATION
Product declaration Specially selected cements, silica sand and reactive fillers
Composition Component A: Powder
Component B: Liquid
Packaging Available in 20 kg double pack

Product Data Sheet


SikaTop®-550 Seal
March 2024, Version 01.04
020701000000002024

1/3
Shelf life Minimum 9 months from date of production if stored properly in undam-
aged and original sealed packaging.
Storage conditions Store in original unopened packaging in cool and dry conditions between
+5 °C and +35 °C. Protect from direct sunlight and frost.
Appearance and colour Available in three standard colours:
▪ Light Grey
▪ White
▪ Dark Grey
Density ~ 1.82 kg/l (fresh mortar at +25°C)

TECHNICAL INFORMATION
Water permeability < 0.1 kg (m2xh0.5) (BS EN 1062-3: 2008)

Water penetration under pressure Nil (BS EN 12390 Part 8: 2009)

Permeability to carbon dioxide > 50 m (BS EN 1062-6: 2002 Method A)


Equivalent air layer thickness (SD)

Chloride ion diffusion resistance SikaTop®-550 Seal provides an effective barrier to waterborne salts such as
chlorides and sulphates.
Note: lndependent assessment has shown that even after 12 months constant im-
mersion the chloride ion diffusion co-efficient could not be measured for SikaTop®-
550 Seal.
Chloride Ion Ingress Not measurable after 24 months of testing
Chemical resistance SikaTop®-550 Seal has outstanding wear and weather resistance and good
resistance to sodium hydroxide, calcium chloride, de-icing salts.
SikaTop®-550 Seal coated surfaces exhibit good resistance to mild acids.
Carbonation resistance SikaTop®-550 Seal is an extremely effective barrier to atmospheric acidic
gases which cause carbonation in concrete structures.
SikaTop®-550 Seal at an applied rate of 1.8 kg/m² gives an equivalent air
layer thickness for carbon dioxide diffusion (R) of 92 m. The accepted min-
imum value for R is 50 m.

APPLICATION INFORMATION
Consumption ~1.8 kg/m² at 1 mm thickness
Layer thickness 1 mm with constant thickness for each layer, minimum 2 layers
Ambient air temperature +5°C min. / 40°C max.
Substrate temperature +5°C min. / 40°C max.
Waiting time to overcoating Waiting time between coats:
+20°C ~6 hours
+30°C ~3 hours

BASIS OF PRODUCT DATA ment.


▪ Where subsequent tiling works are to be carried out
▪ All technical data stated in this Data Sheet are based on vertical surfaces, contact the local Sika represent-
on laboratory tests. Actual measured data may vary ative for advice.
▪ Avoid application in direct sun and/or strong wind.
due to circumstances beyond our control.
▪ Internal Reference - Version: BASF_CC-UAE/ ▪ Do not add water in any circumstances.
Sl_550_12_94/v6/07_17/v7/04_18/v8/12_18/v9/09_19 ▪ Do not mix partialy, mix only full kits.
▪ Protect freshly applied material from freezing condi-
IMPORTANT CONSIDERATIONS tions and rain, etc.

▪ Spray application is recommended for large areas,


for details contact Sika’s Technical Service Depart-

Product Data Sheet


SikaTop®-550 Seal
March 2024, Version 01.04
020701000000002024

2/3
ECOLOGY, HEALTH AND SAFETY As a mortar:
User must read the most recent corresponding Safety When SikaTop®-550 Seal is applied by trowel (e.g. for
Data Sheets (SDS) before using any products. The SDS a smooth surface finish), apply 2 coats in crosswise
provides information and advice on the safe handling, direction. Apply 2nd coat of SikaTop®-550 Seal as soon
storage and disposal of chemical products and con- as the first coat has hardened.
tains physical, ecological, toxicological and other As pore / blowhole filler:
safety-related data. Tightly trowel into the pores / blowholes of the sur-
face.
APPLICATION INSTRUCTIONS CLEANING OF EQUIPMENT
SUBSTRATE QUALITY / PRE-TREATMENT Clean all tools and application equipment with clean
water immediately after use.
Substrates must be structurally sound, clean, dry and Hardened / cured material can only be removed
free of all contaminants such as dirt, oil, grease, ce- mechanically.
ment laitance, coatings and other surface treatments
etc.
Clean surfaces by blast cleaning, high-pressure water-
LOCAL RESTRICTIONS
jetting (400 bar), wire-brushing, grinding etc., in order Note that as a result of specific local regulations the
to remove all previous coatings, any traces of grease, declared data and recommended uses for this product
rust, release agents, cement laitance and any other may vary from country to country. Consult the local
material which could reduce adhesion. All dust depos- Product Data Sheet for exact product data and uses.
its from this preparation must also be removed that is
by vacuum.
Repair concrete substrates, if necessary, with an ap-
LEGAL NOTES
propriate cementitious mortar from the SikaEmaco®,
The information, and, in particular, the recommenda-
SikaRep® or Sika MonoTop® range of repair materials.
tions relating to the application and end-use of Sika
For applications in hot climates / environments and /
products, are given in good faith based on Sika's cur-
or on absorbent substrates, thoroughly pre-dampen
rent knowledge and experience of the products when
the surface immediately prior to the product applica-
properly stored, handled and applied under normal
tion, but avoid any ponding / standing water on the
conditions in accordance with Sika's recommenda-
surface, which must not be damp to touch and not
tions. In practice, the differences in materials, sub-
with a dark-matt / wet surface appearance i.e. it must
strates and actual site conditions are such that no war-
be saturated surface dry (SSD).
ranty in respect of merchantability or of fitness for a
MIXING particular purpose, nor any liability arising out of any
legal relationship whatsoever, can be inferred either
SikaTop®-550 Seal can be mixed with a low speed from this information, or from any written recom-
(~500 r.p.m.) electric drill mixer. Shake carefully Comp. mendations, or from any other advice offered. The
B before using. Then pour ~½ Comp. B into a suitable user of the product must test the product’s suitability
mixing container and add Comp. A slowly while mix- for the intended application and purpose. Sika re-
ing. When homogeneous, add the remaining amount serves the right to change the properties of its
of Comp. B, and mix thoroughly at least for 3 minutes, products. The proprietary rights of third parties must
until the proper lump-free consistency is reached. be observed. All orders are accepted subject to our
Do not add any additional water or other ingredients; current terms of sale and delivery. Users must always
each packaging unit must be entirely mixed. refer to the most recent issue of the local Product
Data Sheet for the product concerned, copies of which
APPLICATION METHOD / TOOLS will be supplied on request.
As a slurry:
Apply 1st coat of mixed SikaTop®-550 Seal either
mechanically, by spray, or by hand using a stiff brush.
Apply in the same direction.
Apply 2nd coat of SikaTop®-550 Seal in crosswise direc-
tion to the first coat application, as soon as first coat
has hardened.

Sika Gulf B.S.C. (c) Sika UAE LLC Sika Saudi Arabia Limited Sika LLC - Oman
Tel: +973 177 38188 Sika MB Construction Chemicals LLC Riyadh / Jeddah / Dammam / Rabigh Master Builders Solutions LLC
Email: [email protected] Sika International Chemicals LLC Tel: +966 11 217 6532 (part of Sika)
Sika Kuwait Cons. Mat. & Paints Co WLL Tel: +971 4 439 8200 Email: [email protected] Tel. +968 22 826 500
Tel: +965 22 282 296 Email: [email protected] Web: gcc.sika.com Email: [email protected]
Email: [email protected] Web: gcc.sika.com Web: gcc.sika.com
Web: gcc.sika.com

SikaTop-550Seal-en-AE-(03-2024)-1-4.pdf

Product Data Sheet


SikaTop®-550 Seal
March 2024, Version 01.04
020701000000002024

3/3

You might also like