CrossLab LC 5991 1484EN

Download as pdf or txt
Download as pdf or txt
You are on page 1of 100

00_Cover_Layout 1 11/29/12 11:12 AM Page 1

CrossLab
Agilent
Supplies Selection Guide
for HPLC and
Electrochemistry Systems

Agilent CrossLab Selection Guide for HPLC & Electrochemistry Systems


2013 EDITION

For more information

Learn more:
www.agilent.com/chem/CrossLabHPLC
www.agilent.com/chem/CrossLabElectrochemistry

Buy online:
www.agilent.com/chem/store

U.S. and Canada


1-800-227-9770
[email protected]

Europe
[email protected]

Asia Pacific
[email protected]

India
[email protected] Put Agilent quality supplies
to work across your lab

Agilent CrossLab HPLC works with WATERS SHIMADZU THERMO SCIENTIFIC AND MORE

This information is subject to change without notice.


© Agilent Technologies, Inc. 2012
Printed in USA November 29, 2012
5991-1484EN
00_Cover_Layout 1 11/29/12 11:12 AM Page 2

Agilent CrossLab Selection Guide


for HPLC & Electrochemistry Systems
The Agilent LC Columns Family:
Choice, control and assured excellent results
Table of Contents Agilent designs and manufactures columns to suit most
techniques for small molecule, biomolecule and synthetic
polymer analysis, allowing you to scale methods from
1 CrossLab Product Introductions conventional 5 µm… to “Fast LC” sub-2 µm… to prep.
You have access to Agilent’s extensive applications
library for faster method development – plus worldwide
27 CrossLab Supplies for Waters HPLC Systems technical support, speedy problem resolution, our global
infrastructure, and delivery network.
Agilent’s meticulous production oversight ensures
42 CrossLab Supplies for Shimadzu HPLC Systems column consistency and performance. With more than
40 years of experience in producing polymers and silica
chemistries, our team is committed to continuously
developing new column advances that make you
49 CrossLab Supplies for Dionex HPLC Systems* most productive.
Learn more at
www.agilent.com/chem/lccolumns
64 CrossLab Supplies for CTC Analytics HPLC Autosamplers

65 CrossLab Vials and Closures

Simplify your workflow


89 CrossLab Well Plates and Sealing Mats
with Captiva Filtration
Family of Products
92 CrossLab Supplies for pH Meters
Maximize the benefits of Captiva
with these additional products
*Dionex is now a part of Thermo Scientific

Agilent Bond Elut SPE, Bond Elut QuEChERS


and Captiva Filtration Sample Prep family of products
offer the widest range of solutions for every level
of sample cleanliness to help you increase throughput
and increase the quality of your data.
Learn more at
www.agilent.com/chem/sampleprep
01_Intro_Layout 1 12/4/12 11:02 AM Page 1

CrossLab Product Introductions


CrossLab
Agilent CrossLab offers a growing portfolio of HPLC and electrochemistry supplies manufactured
for seamless performance with a variety of analytical instruments in your lab. Look inside this
selection guide to find a wide range of products for your applications.
Agilent

We currently support HPLCs from: We currently support pH Meters from:

• Waters • Mettler Toledo


• Shimadzu • Thermo Scientific
• Dionex* • HANNA Instruments
• CTC Analytics
And more to come

Our growing HPLC supplies portfolio includes the following products:

• Autosampler syringes • Sample loops


• Capillaries, tubing, and fittings • Valve supplies
• Detector lamps • Vials and closures
• Performance Maintenance kits • Well plates
• Pump supplies and sealing mats

Our growing Electrochemistry supplies portfolio includes the following products:

• pH electrodes
• pH buffer solutions
Agilent CrossLab is more than supplies:

• Over 40 years of chromatography expertise


• The right supplies for both routine and challenging applications
• Hassle-free operations and reproducible results
• High-quality products manufactured to Agilent standards
• Technical and application support
• Dependable worldwide availability and delivery
• Convenience of consolidating purchasing
• 90-day risk-free money-back guarantee
*Dionex is now a part of Thermo Scientific

Agilent CrossLab HPLC works with WATERS SHIMADZU THERMO SCIENTIFIC AND MORE

www.agilent.com/chem/CrossLabHPLC 1
01_Intro_Layout 1 11/29/12 10:29 AM Page 2

CrossLab Product Introductions

CrossLab Detector Lamps


Long-life deuterium lamp, 8005-0705 Our detector lamps are designed for precise
alignment and thermal stability
Agilent CrossLab lamps are designed and built to be compatible with a wide variety of detectors,
including Variable Wavelength Detectors (VWD), Multiple Wavelength Detectors (MWD),
and Diode Array Detectors (DAD) or Photodiode Array Detectors (PDA). Each lamp adheres
to the tightest specifications for consistent quality and reproducible performance over the lifetime
of the lamp. Test equipment is regularly calibrated using optical standards certified by NIST
(National Institute of Standards and Technology) or PTB (Physikalisch-Technische Bundesanstalt).

• Manufactured in an ISO 9001 certified environment


• Quartz glass bulbs for extended lifetime
• Individually tested for light intensity, noise and drift, correct operating voltage, and proper
alignment for low lamp-to-lamp variability
• Tight QA/QC with traceability for each lamp throughout every step of the product process
• Both deuterium lamps and tungsten lamps available

Tips & Tools


Deuterium lamps
Each time after a replacement • High output stability and intensity for extended detection capabilities and improved qualification
of a detector lamp, it is at trace level
recommended to perform • Guaranteed lifetime of 2,000 hours
a wavelength calibration test
and an intensity test after
warm up. Tungsten lamps
• Offer coverage in the visible wavelength range for high sensitivity detection
• Average lifetime range from 1,200 to 5,000 hours depending on operation conditions such as
operation cycles, soft start, and operation voltage

2 Agilent CrossLab HPLC & Electrochemistry Supplies Selection Guide


01_Intro_Layout 1 11/29/12 10:29 AM Page 3

CrossLab Product Introductions

CrossLab Vials and Closures


Agilent CrossLab vials and closures are thoroughly tested to ensure the highest level of quality.
Additionally, CrossLab vials are designed for use in a wide range of GCs and HPLCs, including those
from Bruker (formerly Varian), Dionex (now Thermo Scientific), PerkinElmer, Shimadzu, Thermo
Scientific, and Waters. They are:

• Manufactured in an ISO 9001 certified facility


• Made from First Hydrolytic Type 1 Class A or Class B borosilicate glass, which conforms to US Snap top vials with write-on spot,
FDA, USP, and EU Pharmacopeia standards 8010-0025

• Protected by proprietary packaging with a crush barrier to reduce vial breakage


• Packaged in material that has been tested and selected for cleanliness
• Subjected to rigorous end-of-line sampling and quality control procedures to ensure all vials
remain within specifications
• Compatible with a wide variety of autosamplers regardless of make and model

www.agilent.com/chem/CrossLabHPLC 3
01_Intro_Layout 1 11/29/12 10:29 AM Page 4

CrossLab Product Introductions

CrossLab Well Plates and Sealing Mats


Choose the cleanest well plates
and sealing mats for your autosamplers 96-well plate,
8010-0534

Advantages of Agilent CrossLab well plates: Advantages of Agilent CrossLab sealing mats:

• Made from polypropylene • Protect well contents during storage


• Free from RNase, DNase, Endotoxins, and human DNA • Free from RNase, DNase, Endotoxins, and human DNA
• Chemically resistant to common solvents • Highly flexible for a tight seal and exact fit
• Autoclavable (121 °C/20 min) • Insets in every well eliminate the need for glue during connection
• Alpha-numeric grid • Pierceable with pipette tips (0.5 mL and 1.0 mL sealing mats)
• Compatible with pipetting workstations and multi-channel pipettes • Prevent solvent evaporation
• Raised rims are available with 0.5 mL and 1.0 mL deep well plates • Made from thermoplastic elastomer (TPE) or
for efficient sealing and a reduced risk of cross-contamination ethylene-vinyl acetate (EVA)
during rigorous vortexing • Compatible with common solvents
• Available in 96- or 384-well plate format
• 96-well plates range from 0.2 mL to 2 mL
• 384-well plates available in 0.1 mL and 0.25 mL
• Stackable

Cleanliness of well plates and sealing mats: Agilent CrossLab vs. the competition

Blank in competitor A 1.0 mL 96-well plate


20000000

Blank in competitor B 1.0 mL 96-well plate with matching sealing mat


15000000
Total Ion Current (TIC)

The chemical extraction experiments


Blank in Agilent CrossLab 1.0 mL 96-well plate with matching sealing mat
demonstrate the superior cleanliness
10000000
of the Agilent CrossLab well plates
Reagent blank and sealing mats compared to the
5000000
competition, making them ideal
for LC/MS applications.
System blank
0

0 1 2 3 4 5 6 7 8 9 min

LC/MS ESI positive chromatogram comparison. Reagent blank: 1:1 Acetonitrile/H2O with 0.1% formic acid

4 Agilent CrossLab HPLC & Electrochemistry Supplies Selection Guide


01_Intro_Layout 1 11/29/12 10:29 AM Page 5

CrossLab Product Introductions

Agilent CrossLab Autosampler Syringes and Manual Syringes


Agilent's CrossLab HPLC syringe portfolio contains a broad selection of syringe styles and volumes to provide what you need for accurate and
effective sampling. From autosampler syringes in both large or small volume, to syringes for pump priming, CrossLab syringes meet all form, fit,
and function criteria to support your HPLC systems.

• Accuracy to within ±1% of nominal volume with a precision of 1% at 80% of the total volume
• A chemically inert fluid path of stainless steel, borosilicate Type I glass, or PTFE
• Robust design for long lifetime

Agilent CrossLab Syringe Features


Point style Termination Flange

Needle gauge Barrel with graduations Fitted plunger

www.agilent.com/chem/CrossLabHPLC 5
01_Intro_Layout 1 11/29/12 10:29 AM Page 6

CrossLab Product Introductions

Syringe terminations at the end of the syringe barrel function as the interface between the syringe and its mating connection, such as the needle.
Terminations are offered in a number of different needle and connection configurations to accommodate a broad range of applications.

Fixed Needle

• Economical option for injections


• Preferred for applications requiring trace level samples
• Needle is cemented into the glass syringe barrel at a point corresponding to the zero
graduation mark
• Dead volume is limited to the needle’s internal volume
• Not autoclavable
• Recommended for use where probability of needle bending is minimal

Removable Needle

• Versatile option for injections


• Needle seats precisely at the zero graduation mark
• Needle can be replaced if damaged or clogged
• Allows for a removable needle without increasing dead volume
• Ideal for when there is a risk of needle clogging
• Autoclavable when disassembled (repeated autoclaving shortens syringe life)

PTFE Luer Lock

• PTFE, male Luer taper with nickel-plated brass locking hub for use with Kel-F needles
or metal hub needles, and universal connectors
• Autoclavable when disassembled, except on 25 mL or greater syringes
(repeated autoclaving shortens syringe life)

Chem

• ¼-28 UNF male fitting thread connection


• Used for low-volume applications where system dead volume must be minimized
• Can be screwed directly into injection valves

6 Agilent CrossLab HPLC & Electrochemistry Supplies Selection Guide


01_Intro_Layout 1 12/4/12 11:03 AM Page 7

CrossLab Product Introductions

Note: Most manual HPLC injection valves are designed


to be used with a 22-gauge, or a 22s-gauge blunt
Needle Gauge 22 Needle Point Style 3 needle point style 3.

Gauge Selection Chart

Nominal OD Nominal ID Wall Thickness Volume


Gauge in mm in mm in mm µL/in
22s* 0.0280-0.0285 0.718 0.0055-0.0077 0.168 0.022 0.55 0.563
22 0.0280-0.0285 0.718 0.0155-0.0170 0.413 0.012 0.30 3.403
*Note: 22s needles have a smaller inner diameter and a thicker wall for better durability.

Tips & Tools


Replace syringe if dirt is noticeable, syringes cannot be cleaned, or plunger does not slide easily.

Tips & Tools


Follow manufacturer's recommendation for syringe cleaning and regularly inspect syringe barrel for sample build-up and needle tip for wear.

www.agilent.com/chem/CrossLabHPLC 7
01_Intro_Layout 1 11/29/12 10:30 AM Page 8

CrossLab Product Introductions

Autosampler Routine Maintenance


Routine autosampler maintenance should be performed on a regular basis to keep your HPLC system
performing at its optimum level. You can perform all maintenance procedures at once or as needed.
Some parts may need to be replaced more often than others depending upon your application and
solvent preparation procedures.
Regular autosampler maintenance helps lower operating costs and generate precise results with the
utmost confidence. By following a regular maintenance routine, you can count on maximum uptime
during the life of your autosampler.

Waters Autosampler Routine Maintenance Procedures


• Replace the metering syringe
• Rebuild the injector seal pack and replace the needle
• Rebuild the high-pressure motorized valves
• Replace the in-line filter insert
• Adjust the seal pack seal valves

Waters Autosampler Routine Maintenance and Troubleshooting

Symptom Cause Solution


Poor injection reproducibility Low sample level in vials Confirm sample level in the vials is at minimum a quarter full
Worn metering syringe Replace the metering syringe assembly
Worn high-pressure motorized valve seals Rebuild the high-pressure motorized valves
Leaking waste valve Replace the waste valve
Worn injector seals Rebuild the injector seal pack, replace the needle, and adjust
the seal pack seal valves
Leaking syringe Worn metering syringe Replace the metering syringe assembly
Sample carryover Needlewash solvent exhausted Refill the needlewash solvent reservoir
Dirty needlewash seals Rebuild the seal pack and adjust seal pack seal valves
Faulty needlewash valve Replace the needlewash valve
Sample vials filling during injection cycle Worn high-pressure motorized valve seal Rebuild the high-pressure motorized valves
Low peak response Low sample level in vials Confirm sample level in the vials is at minimum a quarter full
Worn metering syringe Replace the metering syringe assembly
Worn high-pressure motorized valve seals Rebuild the high-pressure motorized valves
Leaking waste valve Replace the waste valve
Worn injector seals Rebuild the injector seal pack, replace the needle, and adjust
the seal pack seal valves

8 Agilent CrossLab HPLC & Electrochemistry Supplies Selection Guide


01_Intro_Layout 1 11/29/12 10:30 AM Page 9

CrossLab Product Introductions

Shimadzu Autosampler Routine Maintenance Procedures


• Replace the sample metering drive plunger seal
• Replace the sample needle
• Replace the needle seat seal
• If equipped, replace the rinse port septum
• If equipped, clean the high-pressure valve and replace the high-pressure valve rotor seal
• If equipped, clean the low-pressure valve and replace the low-pressure valve rotor seal
• If equipped, clean the injection valve and replace the injection valve rotor seal
• Adjust the needle if necessary

Shimadzu Autosampler Routine Maintenance and Troubleshooting

Symptom Cause Solution


Poor injection reproducibility Low sample level in vials Confirm sample level in the vials is at minimum a quarter full
Worn metering seal Replace the metering plunger seal
Damaged metering plunger Replace the metering plunger
Worn high-pressure valve seals Rebuild the high-pressure valve
Worn low-pressure valve seals Rebuild the low-pressure valve
Leaking waste valve Replace the waste valve
Damaged sample needle Replace the sample needle and needle seat seal
Sample carryover Needlewash solvent exhausted Refill the needlewash solvent reservoir
Dirty needlewash seals Rebuild the seal pack and adjust seal pack seal values
Contaminated rinse port Clean and flush the rinse port
Low peak response Low sample level in vials Confirm sample level in the vials is at minimum a quarter full
Worn metering plunger seal Replace the metering plunger seal
Damaged metering plunger Replace the metering plunger
Worn high-pressure valve seals Rebuild the high-pressure valve
Leaking waste valve Replace the waste valve
Damaged sample needle Replace the sample needle and needle seat seal

www.agilent.com/chem/CrossLabHPLC 9
01_Intro_Layout 1 11/29/12 10:30 AM Page 10

CrossLab Product Introductions

Dionex* Autosampler Routine Maintenance Procedures


• Replace the sample metering syringe
• Replace the sample needle
• Replace the needle seat seal
• If equipped, clean the injection valve and replace the injection valve rotor seal
• Replace the buffer tubing
• Replace the capillary tubing
• Fill the syringe reservoir
• Adjust the needle if necessary
*Dionex is now a part of Thermo Scientific

Dionex Autosampler Routine Maintenance and Troubleshooting

Symptom Cause Solution


Poor injection reproducibility Low sample level in vials Confirm sample level in the vials is at minimum a quarter full
Worn metering syringe seal Replace the metering syringe
Worn syringe valve Replace the syringe valve
Worn injection valve seal Rebuild the injection valve
Leaking waste valve Replace the waste valve
Leaking fittings Check all the fittings for leaks
Damaged sample needle Replace the sample needle and needle seat seal
Sample carryover Needlewash solvent exhausted Refill the needlewash solvent reservoir
Dirty needlewash seals Rebuild the seal pack and adjust seal pack seal valves
Contaminated rinse port Clean and flush the rinse port
Leaking syringe Damaged syringe Replace the syringe
Worn syringe valve Check for leaks and replace if necessary
Low peak response Low sample level in vials Confirm sample level in the vials is at minimum a quarter full
Worn syringe valve Replace the metering syringe
Damaged syringe valve Check the syringe valve for leaks and replace if necessary
Worn injector valve seal Rebuild the injection valve
Leaking waste valve Replace the waste valve
Leaking fittings Check all the fittings for leaks
Damaged sample needle Replace the sample needle and needle seat seal

10 Agilent CrossLab HPLC & Electrochemistry Supplies Selection Guide


01_Intro_Layout 1 11/29/12 10:30 AM Page 11

CrossLab Product Introductions

CrossLab Pump Supplies


Proper pump maintenance helps ensure precise,
consistent results and lower operating costs Sapphire plunger assembly, 8005-0538

Regular pump maintenance helps lower operating costs and ensure precise and consistent results.
By following a regular maintenance routine, you can count on maximum uptime, steady and accurate
solvent flow, pressure stability throughout the life of a pump, and keep your HPLC system in its
optimum condition.

Plunger seal replacement kit, 8005-0541

CrossLab Plungers and Seals


Plungers (or pistons) and seals are two of the most important components of a pump. All Agilent
CrossLab plungers combined with seals undergo extensive testing under temperature stress with
common HPLC solvents for reproducible results.

Plungers:
Face seals replacement kit, 8005-0536
• Available in sapphire or ceramic
• Sapphire plungers are made from high purity monocrystalline sapphire for optimal concentricity
and resistance to wear
• Are meticulously cut and polished for great durability and long life Tips & Tools
Plungers (or pistons) should be
Seals: exchanged on a regular basis in
combination with seals to maintain
• Manufactured from ultra-high-molecular-weight polyethylene (UHMWPE) or graphite-filled the best sealing surface and
polytetrafluoroethylene (GFP)
durability for optimal instrument
• Designed to provide precise sealing around the plungers performance.
• Engineered to deliver top performance over highly dynamic flow and pressure ranges

Tips & Tools


Depending on your applications and
solvent preparation protocols, some
parts may need to be replaced more
often than the others.

www.agilent.com/chem/CrossLabHPLC 11
01_Intro_Layout 1 11/29/12 10:30 AM Page 12

CrossLab Product Introductions

CrossLab Check Valves


Check valves are key components for a pump, and their lifetime is often related to the solvents used.
A defective valve can lead to pressure fluctuation, inconsistent flow, and a noisy baseline.

Agilent CrossLab check valves and assembly components:

• Made to operate at different pressures (up to 16,000 psi, or 1,100 bar) per specifications
from the Original Equipment Manufacturers (OEMs)
• Made from a variety of materials, such as stainless steel, titanium, ceramic, and PEEK,
depending on OEM specifications
• Carefully assembled to ensure reliability and consistent performance
• Each ruby or ceramic ball and sapphire or ceramic seat is manufactured under extremely tight
tolerances to ensure proper sealing within the operating pressure range

Tips & Tools


Don't forget to check your check valve regularly and replace check valve cartridges to ensure proper pump operations.

12 Agilent CrossLab HPLC & Electrochemistry Supplies Selection Guide


01_Intro_Layout 1 11/29/12 10:30 AM Page 13

CrossLab Product Introductions

HPLC Pump Routine Maintenance


Routine pump maintenance should be performed on a regular basis to keep your HPLC system Tips & Tools
performing at its optimum level. You can perform all maintenance procedures at once or as needed. Pump seals should be replaced
Some parts may need to be replaced more often than others depending upon your application and when there are leaks on the bottom
solvent preparation procedures. of the pump head, when retention
Regular pump maintenance helps lower operating costs and generate precise results with the utmost times are inconsistent, or when
confidence. By following a regular maintenance routine, you can count on maximum uptime and a the pressure ripple is unstable.
steady, accurate solvent flow for the life of the pump.

Waters Pump Routine Maintenance Procedures


• Replace the seals and plungers (or pistons)
• Replace the in-line filter insert
• Replace the check valve cartridges
• Replace the seal wash seals and tube seals
• Replace the solvent inlet frits
Sapphire plunger assembly, 8005-0523

Waters Pump Routine Maintenance Procedures

Symptom Cause Solution


Pressure ripple unstable Dirty check valve cartridge(s) Run static leak test to verify and exchange the check valve
cartridge(s)
Leak on pump head Run static leak test to verify and exchange the in-line filter
insert and plunger (or piston) seals
Gradient performance problems Blocked solvent filter(s) Change the solvent filter(s)
Intermittent pressure fluctuations
A pressure drop of greater than 10 bar (150 psi) across Dirty in-line filter Exchange the in-line filter insert
the in-line filter (5 mL/min H2O during wet priming)
Leaks at lower pump head side High seal wear Run leak test to verify and exchange the pump seals and
Unstable retention time in-line filter insert

Pressure ripple unstable


Seal lifetime shorter than normally expected Scratch on plunger Check plungers while changing the seals
Exchange the plungers if damaged or scratched
Loss of wash solvent Leaky wash seals Exchange the wash seals

www.agilent.com/chem/CrossLabHPLC 13
01_Intro_Layout 1 11/29/12 10:30 AM Page 14

CrossLab Product Introductions

Shimadzu Pump Routine Maintenance Procedures


• Replace the seals and plungers (or pistons)
• Replace the in-line filter cartridge
• Replace the check valve cartridges
Plunger seal, 8001-0502 • Replace the seal wash seals
• Replace the solvent inlet frits

Shimadzu Pump Routine Maintenance and Troubleshooting

Symptom Cause Solution


Pressure ripple unstable Dirty check valve cartridge(s) Run Pump Pressure test to verify and exchange the check
valve cartridge(s)
Leak on pump head Run Pump Pressure test to verify and exchange the in-line
filter insert and plunger (or piston) seal
Check inlet and outlet fittings for leaks
Tighten all fittings and re-run the Pump Pressure test
Gradient performance problems Blocked solvent filter(s) Change the solvent filter(s)
Intermittent pressure fluctuations
A pressure drop of greater than 10 bar (150 psi) across Dirty in-line filter Exchange the in-line filter insert
the in-line filter (5 mL/min H2O during wet priming)
Leaks at lower pump head side High seal wear Run Pump Pressure test to verify and exchange the pump
Unstable retention time seals and in-line filter cartridge

Pressure ripple unstable


Broad peaks or peak tailing
Seal lifetime shorter than normally expected Scratch on plunger Check plungers while changing the seals
Exchange the plungers if damaged or scratched
Loss of wash solvent Leaky wash seals Exchange the wash seals

14 Agilent CrossLab HPLC & Electrochemistry Supplies Selection Guide


01_Intro_Layout 1 11/29/12 10:30 AM Page 15

CrossLab Product Introductions

Dionex* Pump Routine Maintenance Procedures


• Replace the purge valve cap seal
• Replace the seals, seal rings, and plungers (or pistons)
• Replace the in-line filter cartridge
• Replace the check valve cartridges Vespel rotor seal, 8002-0602
• Replace the seal wash seals and seal wash tubing
• Replace the mixing chamber gasket
• Replace the solvent inlet filter frits
*Dionex is now a part of Thermo Scientific

Dionex Pump Routine Maintenance and Troubleshooting

Symptom Cause Solution


Pressure ripple unstable Dirty check valve cartridge(s) Run Pump Pressure test to verify and exchange the check
valve cartridge(s)
Leak on pump head Run Pump Pressure test to verify and exchange the in-line
filter insert and plunger (or piston) seal
Check inlet and outlet fittings for leaks
Tighten all fittings and re-run the Pump Pressure test
Gradient performance problems, Blocked solvent filter(s) Change the solvent filter(s)
Intermittent pressure fluctuations
A pressure drop of greater than 10 bar (150 psi) across Dirty in-line filter Exchange the in-line filter insert
the in-line filter (5 mL/min H2O during wet priming)
Leaks at lower pump head side High seal wear Run Pump Pressure test to verify and exchange the pump
Unstable retention time seals and in-line filter cartridge

Pressure ripple unstable


Broad peaks or peak tailing
Seal lifetime shorter than normally expected Scratch on plunger Check plungers while changing the seals
Exchange the plungers if damaged or scratched
Loss of wash solvent Leaky wash seals Exchange the wash seals and seal wash tubing

www.agilent.com/chem/CrossLabHPLC 15
01_Intro_Layout 1 11/29/12 10:30 AM Page 16

CrossLab Product Introductions

CrossLab Valve Supplies


Agilent CrossLab valve supplies work seamlessly with your HPLC systems for reliable, accurate,
and reproducible results.

Rotor, 6-port valve, 8001-0601 Rotor seals:


A variety of materials for a wide range of applications
A rotor seal is a polymeric disk that creates a high-pressure seal against the stator or stator face seal.
A variety of materials are available for different applications. It is important to replace rotor seals on
a routine basis to prevent excessive wear. The recommended replacement interval for most rotor
seals is once per year for preventive maintenance or as needed depending on stresses imposed
by specific applications.
Tips & Tools
• Vespel: Vespel is a polyimide with low wear and high chemical resistance. Recommended
PEEK rotor seals are incompatible for use with solutions under pH 10 because more basic solutions dissolve Vespel over time
with concentrated nitric and damage the rotor seal
and sulfuric acids. • PEEK (Polyetheretherketone): PEEK offers high resistance, versatility, and applicability
for the entire pH range between 0 and 14
• Tefzel: Recommended for use in applications where PEEK cannot be used, such as higher
concentrations of methylene chloride or dimethyl sulfoxide (DMSO)

Recommended pH levels for rotor seal materials


Tips & Tools
pH Range 0-7 7-10 10-14
For any solution above pH 10,
Vespel
a PEEK rotor seal is recommended.
PEEK
Tefzel

Looking for electrochemistry supplies?


Please see page 92.

The Agilent CrossLab Electrochemistry portfolio includes a variety of electrodes and pH buffers
designed for pH meters from Mettler Toledo, Thermo Scientific, and HANNA Instruments.

16 Agilent CrossLab HPLC & Electrochemistry Supplies Selection Guide


01_Intro_Layout 1 11/29/12 10:30 AM Page 17

CrossLab Product Introductions

Stators
• Available in 316 stainless steel, PEEK, and ceramic depending on the specifications of OEMs
• Typically require replacement only if the ports or sealing surfaces become damaged, which can
be prevented by using proper injection needles

Stator, 6-port valve, 8001-0604


Sample Loops
Stainless Steel Sample Loops:
• Have burr-free and square-cut ends to ensure a flush connection to valve ports
• Actual volumes might differ due to tolerance of metal tubing bore
• Accuracy of large metal loops (1.0 mm, 0.040 in bore) is ± 14%, intermediate loops (0.5 mm,
0.020 in bore) is ± 21%, and small loops (0.2 mm, 0.007 in bore) is ± 65%

PEEK Sample Loops


• Alternative to stainless steel sample loops
• Clean, straight cuts for easy valve installation and low dead volume connections
• Inert to almost all organic solvents and biocompatible
• Actual volumes might differ due to tolerance of metal tubing bore
• Accuracy of large PEEK loops (0.8 mm, 0.030 in bore) is ± 5%, intermediate loops Tips & Tools
(0.5 mm, 0.020 in bore) is ± 10%, and small loops (0.2 mm, 0.007 in bore) is ± 30%
Concentrated nitric acid and sulfuric
• Wall thickness, temperature, concentration of organic solvent, and solvent exposure time acid weaken PEEK tubing while
affect the durability of PEEK tubing tetrahydrofuran (THF), methylene
chloride, and DMSO cause swelling.

Tips & Tools


Since both standards and unknowns
are usually analyzed using the same
sample loops, knowledge of the
actual, accurate volume is rarely
needed. If the sample loop volume
must be known, it is best to
calibrate the loop in place on the
valve so the flow passages in the
valve are taken into account.

www.agilent.com/chem/CrossLabHPLC 17
01_Intro_Layout 1 11/29/12 10:30 AM Page 18

CrossLab Product Introductions

CrossLab Performance Maintenance


(PM) Kits
515 pump PM kit, 8005-0913
PM kits make it easier to keep your instruments
running at peak performance
Many instrument failures are not caused by functional breakdowns, but by a lack of performance
maintenance. As suggested by a recent study, a regular performance maintenance program can
reduce instrument failure rates up to 25%, and is critical to ensure optimal overall system operations.
2960/2965 PM kit, 8005-0915

The Effect of Performance Maintenance


Predicted failure
rate extrapolation
Number of Installed Instruments

Up to 25%
reduction
in failures
Failures
Improved performance

Failure
maintenance regime
implemented on site

Time

Agilent CrossLab PM kits contain the normal wear parts, tools for disassembly/reassembly,
and instructions necessary to keep your systems operating at peak performance. The kits provide
a convenient, cost-effective way to make sure your instruments are properly maintained.
Each kit contains all the parts you need to:

• Boost system efficiency and reliability


• Reduce unplanned downtime and repair costs
• Increase accuracy by enhancing precision and sensitivity
• Comply with regulatory requirements, or meet quality accreditation standards
• Extend instrument life
• Eliminate individual part ordering
• PM kits available for pumps, valves, autosamplers, and HPLC systems

18 Agilent CrossLab HPLC & Electrochemistry Supplies Selection Guide


01_Intro_Layout 1 11/29/12 10:30 AM Page 19

CrossLab Product Introductions

General HPLC Supplies


CrossLab HPLC Capillaries and Tubing
CrossLab capillary, stainless steel,
8005-0825
Your link to analytical success
Agilent CrossLab offers a range of capillaries and tubing made from stainless steel and PEEK. Used in
combination with the right fittings, they are ideal for HPLC system plumbing, providing an inert surface,
tight, leak-free connections, and zero dead volumes.

Stainless steel capillaries


• Made of ultra-clean stainless steel tubing
• Ideal for most standard applications, and the best choice for reliable high-pressure sealing
• Smooth inner surface for the lowest backpressure ETFE tubing for use between the inlet block
and the check valve, 8001-0807
• Precision cutting for burr-free, square-cut ends without inner-diameter distortion
• Both ends accept standard fittings
• Predefined lengths for specific path locations to avoid peak broadening
• Individually tested to ensure reproducibility
• Available in pre-swaged and non pre-swaged

PEEK tubing
CrossLab capillary and fitting kit, 8002-0817
• Flexible and easy to cut to desired lengths
• Ideal for frequently changed connections
• Resists mechanical and solvent damage, even at high temperatures
• Biocompatible and inert to almost all organic solvents
• A durable alternative to stainless steel connections Tips & Tools
• Accepts both stainless steel and PEEK fittings
Always use the smallest capillary
internal diameter and the shortest
length to keep sample dispersion
as low as possible.

www.agilent.com/chem/CrossLabHPLC 19
01_Intro_Layout 1 11/29/12 10:30 AM Page 20

CrossLab Product Introductions

CrossLab Fittings
The right HPLC fittings make the best connections
Flangeless nut, M6, 8001-0813
To ensure leak-free connections, and to prevent the loss of peak shape and resolution, always use
the recommended fitting style for columns, valves and unions.
With Agilent CrossLab fittings, you get the confidence and choice that come with:

• Robust design for long life and smooth, leak-free operation


• Stainless steel nuts and ferrules for high-pressure systems
Blind nut, FS-8 biocompatible, 8002-0802 • Polymer fittings for biocompatible applications

20 Agilent CrossLab HPLC & Electrochemistry Supplies Selection Guide


01_Intro_Layout 1 11/29/12 10:30 AM Page 21

CrossLab Product Introductions

CrossLab HPLC In-Line Filters


Help stop time-wasting blockages
Column inlet frit contamination can increase backpressure and reduce efficiency. Microbore column
blockages are of particular concern, due to the frit’s small diameter.
Stainless steel in-line filter, 8001-0808
To help prevent time-wasting contamination and blockages, the Agilent CrossLab portfolio offers two
types of HPLC filters made from clean, high-quality stainless steel parts:

• In-line solvent filters, installed between the HPLC pump and injector, prevent blockages by
removing particles from solvents before they reach the injector
• Column inlet filters, positioned immediately before an HPLC column, remove particles from both
the injection system and sample

Filter frit for titanium in-line filter, 2 µL,


8002-0806

www.agilent.com/chem/CrossLabHPLC 21
01_Intro_Layout 1 11/29/12 10:30 AM Page 22

CrossLab Product Introductions

CrossLab pH Electrodes
Agilent CrossLab pH electrodes contain various selections to meet different application requirements.
The portfolio is supported by uncompromising construction, materials, and quality control for
ease-of-use, durability, and accuracy.

• Quick response and accurate results due to a unique reference system assured by proprietary
materials and manufacturing process

• Made from multi-layered composite materials for extra durability compared to the traditional
single-layer breathable membrane

• Built-in barrier for protecting glass bubble against breakage


• Annular fiber polymer materials being leveraged for some electrode liquid junctions to mitigate
clogging and sample contamination

• Universal connections for easy interchange with a wide range of popular benchtop meters
• Compatible with pH meters from Mettler Toledo, Thermo Scientific, and HANNA Instruments

Non-refillable pH combination electrode with ABS body, 8010-0975

pH combination electrode, 8010-0986

Non-refillable pH electrode with glass body, 8010-0973

22 Agilent CrossLab HPLC & Electrochemistry Supplies Selection Guide


01_Intro_Layout 1 11/29/12 10:30 AM Page 23

CrossLab Product Introductions

Troubleshooting Guide for HPLC Systems


The at-a-glance tables can help you pinpoint and solve the most common problems for your HPLC systems and ensure maximum instrument
uptime and productivity.

HPLC Troubleshooting

Symptom Type Possible Cause Solution


Baseline disturbance Positive/negative – Difference in refractive index Use mobile phase for sample solvent
at void time of injection solvent
Detector leaks Plugged inlet frit Replace seals/gaskets
Drifting baseline Positive direction – Contaminant buildup/elution Flush column, clean up sample, use pure solvents
Positive/negative – Difference in refractive index Use mobile phase for sample solvent
of injection solvent
Negative direction (gradient) – Absorbance of "A" Use non-absorbing or HPLC-grade or better solvent
mobile phase solvent
Positive direction (gradient) – Absorbance of "B" Use non-absorbing or HPLC-grade or better solvent
mobile phase solvent
Random – Temperature changes Insulate column and tubing
Random – Temperature changes Thermostat column and tubing
Wavy or undulating – Temperature changes in room Monitor room temperature and control
Ghost peaks Peaks from previous injection Flush column to remove contaminants
Contamination Sample cleanup or pre-fractionation
Unknown interferences in samples Sample cleanup or pre-fractionation
Ion-pair – Upset equilibrium Prepare sample in actual mobile phase
to minimize disturbance
Peptide mapping – Oxidation of TFA Prepare fresh daily; use anti-oxidant
Reversed-phase – Contaminated water Check suitability of water by running different amount
through reversed-phase column and measure peak
height with elution; use HPLC grade solvents
Spikes – Bubbles in solvent De-gas solvents

(Continued)

www.agilent.com/chem/CrossLabHPLC 23
01_Intro_Layout 1 11/29/12 10:30 AM Page 24

CrossLab Product Introductions

HPLC Troubleshooting

Symptom Type Possible Cause Solution


High column backpressure Column blockage, adsorbed sample Better sample cleanup; use guard column
Mobile phase viscosity too high Use lower viscosity solvents or higher temperature
Particle size too small Use larger dp packing
Plugged inlet frit Replace column
Plugged inlet frit Reverse solvent flow
Leaks Subtle – White powder at fitting/loose fitting Tighten fittings, cut tubing, or replace ferrules
Leaks, injection valve Catastrophic – Worn valve rotor Replace rotor in valve
Leaks, column Catastrophic – Loose fittings Tighten or replace fittings
or other fittings
Leak, pump Catastrophic – Pump seal failure Replace pump seal
Negative peaks RI detector – solute refractive index less than solvent No problem; reverse polarity to make positive
UV detector – solute absorbance less than mobile phase Use mobile phase with lower UV absorbance;
do not recycle solvent too long
Noisy baseline Random – Contaminant buildup Flush column; clean up sample; use HPLC-grade solvent
Continuous – Detector lamp problem Replace detector lamp
Occasional – External electrical interference Use voltage stabilizer for LC system
Peak doubling Sample volume too large Reduce the volume e.g. by half and re-inject
Injection solvent too strong Use weaker injection solvent or mobile phase
Blocked frit Replace and use 0.5 µm porosity in-line filter
Column void or channeling Replace column; for some columns,
fill in void with packing
Unswept injector flowpath Replace injector rotor
Void at head of column Replace column, top off column with packing
Column overloaded with sample Use higher capacity stationary phase
Increase column diameter
Decrease sample size
Single peak – interfering components Sample cleanup; pre-fractionation

(Continued)

24 Agilent CrossLab HPLC & Electrochemistry Supplies Selection Guide


01_Intro_Layout 1 11/29/12 10:30 AM Page 25

CrossLab Product Introductions

HPLC Troubleshooting

Symptom Type Possible Cause Solution


Peak tailing Beginning of peak doubling See "peak doubling"
Unswept dead volumes Minimize number of connections
Ensure injector seal is tight
Ensure fittings are properly seated
Basic compounds – Silanol interactions Choose endcapped bonded phase
Switch to polymeric phase
Basic substances – Silanol interactions Use stronger mobile phase or add competing base
(e.g. TMA)
Silica-based – Column degradation Use specialty column; polymeric column or sterically
protected
Peaks are broad Injection volume too large Decrease solvent strength of injection solvent
to focus solute
Peak dispersion in injector valve Introduce air bubble in front/back of sample
to decrease dispersion
Sampling rate of data system too slow Increase frequency of sampling
Slow detector time constant Adjust time constant to match peak width
Mobile phase viscosity too high Increase column temperature
Detector cell volume too large Use smallest possible cell volume with no heat
exchanger in system
Injector volume too large Decrease injection volume
Long retention times Use gradient elution or stronger mobile phase
Pressure fluctuation Leaky check valve Replace check valve
Pump seal leaks Replace pump seals
Buildup of particulates Filter sample; in-line filter; filter mobile phase
Pressure increasing Buildup of particulates Filter sample; in-line filter; filter mobile phase
Water/organic systems – buffer precipitation Test buffer-organic mixtures; ensure compatibility
Retention beyond total Size exclusion – specific interactions Add mobile phase modifiers or change solvent
permeation volume

(Continued)

www.agilent.com/chem/CrossLabHPLC 25
01_Intro_Layout 1 11/29/12 10:30 AM Page 26

CrossLab Product Introductions

HPLC Troubleshooting

Symptom Type Possible Cause Solution


Retention times changing Column temperature varying Thermostat column; insulate column;
ensure lab temperature constant
Equilibration time insufficient with gradient run Make sure at least 10 column volumes pass through
or changes in isocratic mobile phase column after solvent change or gradient conclusion
Selective evaporation of mobile phase component Less vigorous helium sparging; keep solvent reservoirs
covered; prepare fresh mobile phase
Buffer capacity insufficient Use >20 mM concentration of buffer
Inconsistent on-line mobile phase mixing Ensure gradient system delivering constant composition;
check vs. manual prep of mobile phase
Contamination buildup Occasionally flush column with strong solvent
to remove contaminants
First few injections – Adsorption on active sites Condition column by initial injection of
concentrated sample
Retention times Flow rate increasing Check pump to make sure correct; if not, reset
decreasing Column overloaded with sample Decrease sample size
Loss of bonded stationary phase Keep mobile phase pH between 2 and 8.5
Retention times increasing Flow rate is slowing Fix leaks in liquid lines, replace pump seals,
check for pump cavitation or air bubbles
Active sites on silica packing Use mobile phase modifier
Loss of bonded stationary phase Keep mobile phase pH between 2 and 8.5
Mobile phase composition changing Make sure mobile phase container is covered
Active sites on silica packing Add competing base to mobile phase
Active sites on silica packing Use higher coverage packing for stationary phase
Sensitivity problem Peaks are outside of linear range of detector Dilute/concentrate to bring into linear region
First few sample injections – Absorption of sample Condition loop/column with concentrated sample
in loop or column
Autosampler flow lines blocked Check flow and make sure there are no blockages
Injector sample loop underfilled Make sure that loop is overfilled with sample
Sample-related losses during preparation Use internal standard during sample prep;
optimize sample prep method
Slow column equilibration Equilibration time slow for long-chain ion-pairing reagents Use shorter alkyl chain ion-pair reagent
times (ion-pairing)

26 Agilent CrossLab HPLC & Electrochemistry Supplies Selection Guide


02_Waters_Layout 1 11/29/12 10:31 AM Page 27

CrossLab Supplies for Waters HPLC Systems

CrossLab Supplies for Waters HPLC Systems


Detector Lamps, 1/pk
Similar to Agilent
OEM CrossLab
Model Description Part No. Part No.
2996 Photodiode Array Detector Long-life deuterium lamp, 2,000 hours WAT052586 8005-0705
996 Photodiode Array Detector
ACQUITY UPLC 2996 Photodiode Array Detector
2487 Dual Wavelength Absorbance Detector Long-life deuterium lamp, 2,000 hours WAS081142 8005-0704
2488 Multichannel Absorbance Detector
ACQUITY TUV Detector
UPLC TUV Detector
486 Tunable UV/Visible Absorbance Detector Long-life deuterium lamp, 2,000 hours 700000356 8005-0702
LC Module 1 WAT052666

The cross references to the original equipment manufacturer (OEM) part numbers listed here serve as a recommendation that the Agilent CrossLab products are viable
alternatives to OEM products. CrossLab products are compatible with the corresponding OEM instruments, although in some cases, the CrossLab products may have slightly
different designs as compared to the OEM counterparts. All CrossLab supplies are backed by Agilent's 90-day money-back warranty.

Long-life deuterium lamp, 8005-0705 Long-life deuterium lamp, 8005-0704 Long-life deuterium lamp, 8005-0702

www.agilent.com/chem/CrossLabHPLC 27
02_Waters_Layout 1 11/29/12 10:31 AM Page 28

CrossLab Supplies for Waters HPLC Systems

Autosampler Syringes, 1/pk


Needle Agilent Agilent
Gauge/ Similar Agilent CrossLab CrossLab Similar to
Volume Length (mm)/ to OEM CrossLab Replacement Replacement OEM
Model (µL) Description Tip Part No. Syringe Needle Plunger Part No.
2777 Compact 10 Fixed needle 22s/51/3 430000859 8010-0445* 8010-0457, 700002212
Sample Manager 10/pk
2777 Sample 25 Fixed needle, 22s/51/3 430000861 8010-0441 8010-0458, 700002213
Manager gas tight 10/pk
100 Fixed needle, 22s/51/3 430000864 8010-0442* 8010-0459, 700002214
gas tight 10/pk
Fixed needle, 22/51/3 430000863 8010-0446* 8010-0459, 700002214
gas tight 10/pk
250 Fixed needle, 22/51/3 430000865 8010-0467 8010-0456, 700002215
gas tight 10/pk
500 Fixed needle, 22/51/3 430000866 8010-0468 8010-0460, 700002216
gas tight 10/pk
1,000 Fixed needle, 22/51/3 430000867 8010-0443 8010-0455 700002217
gas tight
2,500 Fixed needle, 22/51/3 430000868 8010-0444 8010-0448 700002218
gas tight
510 HPLC Pump 10000 Luer Lock No needle WAT025559 8005-0414
515 HPLC Pump
600 MultiSolvent
Delivery System
CapLC System
CapLC XE System
*Barrel od is 6.7 mm. All other 10, 25, and, 100 µL syringes have 7.9 mm od.
(Continued)

The cross references to the original equipment manufacturer (OEM) part numbers listed here serve as a recommendation that the Agilent CrossLab products are viable
alternatives to OEM products. CrossLab products are compatible with the corresponding OEM instruments, although in some cases, the CrossLab products may have slightly
different designs as compared to the OEM counterparts. All CrossLab supplies are backed by Agilent's 90-day money-back warranty.

28 Agilent CrossLab HPLC & Electrochemistry Supplies Selection Guide


02_Waters_Layout 1 11/29/12 10:31 AM Page 29

CrossLab Supplies for Waters HPLC Systems

Autosampler Syringes, 1/pk


Needle Agilent Agilent
Gauge/ Similar Agilent CrossLab CrossLab Similar to
Volume Length (mm)/ to OEM CrossLab Replacement Replacement OEM
Model (µL) Description Tip Part No. Syringe Needle Plunger Part No.
600 MultiSolvent 25 Removable 22s/51/3 WAT033381 8005-0416 8005-0422
Delivery System needle,
Rheodyne Injector gas tight

2690 Separations 25 Chem No needle WAT077343 8005-0420


Module (1/4-28
2690D Dissolution UNF screw
Separations Module threads),
gas tight
2695 Separations
Module
2695D Dissolution
Separations Module
2790 Separations 250 Chem No needle WAT073109 8005-0419
Module (1/4-28 screw
threads UNF),
2795 Separations gas tight
Module
LC Module 1
717/717plus
Autosampler
Rheodyne Injector 100 Removable 22s/51/3 WAT033383 8005-0417 8005-0418, 8005-0423
needle, 6/pk
gas tight

The cross references to the original equipment manufacturer (OEM) part numbers listed here serve as a recommendation that the Agilent CrossLab products are viable
alternatives to OEM products. CrossLab products are compatible with the corresponding OEM instruments, although in some cases, the CrossLab products may have slightly
different designs as compared to the OEM counterparts. All CrossLab supplies are backed by Agilent's 90-day money-back warranty.

CrossLab syringe, PTFE-tipped plunger, Autosampler syringe, gas tight, 8005-0417 CrossLab syringe needle, 22s/51/3,
25 µL, 8005-0420 8005-0418

www.agilent.com/chem/CrossLabHPLC 29
02_Waters_Layout 1 11/29/12 10:31 AM Page 30

CrossLab Supplies for Waters HPLC Systems

Pump Supplies
Similar to Agilent
OEM CrossLab
Model Description Unit Part No. Part No.
Plungers and Seals
2690 Separations Module Sapphire plunger assembly, standard 1/pk WAT270959 8005-0538
2690D Dissolution Separations Module
2695 Separations Module
2695D Dissolution Separations Module
2790 Separations Module
2795 Separations Module
2796 Bioseparations Module
2690 Separations Module Plunger seals, clear 2/pk 700001326 8005-0514
2690D Dissolution Separations Module
2695 Separations Module
2695D Dissolution Separations Module
2690 Separations Module Plunger seal replacement kit, standard, yellow 2/pk WAT270938 8005-0535
2690D Dissolution Separations Module
2695 Separations Module
2695D Dissolution Separations Module
2790 Separations Module
2795 Separations Module
Alliance GPC/V 2000 Systems
2690 Separations Module Plunger seal replacement kit, black 2/pk WAT271066 8005-0541
2690D Dissolution Separations Module
2695 Separations Module
2695D Dissolution Separations Module
2790 Separations Module
2795 Separations Module
2690 Separations Module Face seals replacement kit 4/pk WAT270939 8005-0536
2690D Dissolution Separations Module
2695 Separations Module
2695D Dissolution
Separations Module
2790 Separations Module
2795 Separations Module
Alliance GPC/V 2000 Systems

(Continued)

Plunger seal replacement kit, 8005-0535 Plunger seal replacement kit, 8005-0541 Face seals replacement kit, 8005-0536

30 Agilent CrossLab HPLC & Electrochemistry Supplies Selection Guide


02_Waters_Layout 1 11/29/12 10:31 AM Page 31

CrossLab Supplies for Waters HPLC Systems

Pump Supplies
Similar to Agilent
OEM CrossLab
Model Description Unit Part No. Part No.
Plungers and Seals
2690 Separations Module Seal wash face seal kit 1/pk WAT271017 8005-0539
2690D Dissolution Separations Module
2695 Separations Module
2695D Dissolution Separations Module
2790 Separations Module
2795 Separations Module
Alliance GPC/V 2000 Systems
2796 Bioseparations Module Seal wash, plunger seal 4/pk 700002258 8005-0516
2796 Bioseparations Module Plunger seal, standard 2/pk 700002257 8005-0515
2690 Separations Module Seal wash plunger seal replacement kit 2/pk WAT271018 8005-0540
2690D Dissolution Separations Module
2695 Separations Module
2695D Dissolution Separations Module
2790 Separations Module
2795 Separations Module
Alliance GPC/V 2000 Systems
510 HPLC Pump Sapphire plunger 1/pk WAT025656 8005-0527
600 MultiSolvent Delivery System Oriented sapphire plunger 1/pk WAT069511 8005-0533
610 PowerLine Isocratic Pump
LC Module 1
510 HPLC Pump Plunger seal, graphite-filled PTFE (GFP), black 1/pk WAT026613 8005-0529
515 HPLC Pump
600 MultiSolvent Delivery System
LC Module 1
510 HPLC Pump Plunger seal, black, 225 µL 1/pk WAT026644 8005-0530
515 HPLC Pump
600 MultiSolvent Delivery System
610 PowerLine Isocratic Pump
LC Module 1

(Continued)

The cross references to the original equipment manufacturer (OEM) part numbers listed here serve as a recommendation
that the Agilent CrossLab products are viable alternatives to OEM products. CrossLab products are compatible with the
corresponding OEM instruments, although in some cases, the CrossLab products may have slightly different designs as
compared to the OEM counterparts. All CrossLab supplies are backed by Agilent's 90-day money-back warranty.

Seal wash face seal kit, 8005-0539

www.agilent.com/chem/CrossLabHPLC 31
02_Waters_Layout 1 11/29/12 10:31 AM Page 32

CrossLab Supplies for Waters HPLC Systems

Pump Supplies
Similar to Agilent
OEM CrossLab
Model Description Unit Part No. Part No.
Plungers and Seals
616 LC System Sapphire plunger 1/pk WAT031788 8005-0531
626 LC System
1515 HPLC Pump Sapphire plunger assembly 1/pk WAS207069 8005-0523
1525 HPLC Pump
515 HPLC Pump
1515 HPLC Pump Plunger seal, clear 1/pk WAT022934 8005-0524
1525 HPLC Pump Plunger seal, clear 4/pk WAT022946 8005-0525
510 HPLC Pump
515 HPLC Pump
600 MultiSolvent Delivery System
610 PowerLine Isocratic Pump
LC Module 1
1515 HPLC Pump Aqueous seal kit, 100 µL, ultra-high-molecular-weight 2/pk WAT025296 8005-0909
1525 HPLC Pump polyethylene (UHMWP)
Aqueous seal kit, 100 µL, ultra-high-molecular-weight 4/pk WAT025297 8005-0910
510 HPLC Pump
polyethylene (UHMWP)
515 HPLC Pump
600 MultiSolvent Delivery System
LC Module 1
Check Valves and Cartridges
2690 Separations Module Check valve cartridge replacement kit 2/pk WAT270941 8005-0537
2690D Dissolution Separations Module
2695 Separations Module
2695D Dissolution Separations Module
2790 Separations Module
2795 Separations Module
Alliance GPC/V 2000 Systems

(Continued)

The cross references to the original equipment manufacturer (OEM) part numbers listed here serve as a recommendation that the Agilent CrossLab products are viable
alternatives to OEM products. CrossLab products are compatible with the corresponding OEM instruments, although in some cases, the CrossLab products may have slightly
different designs as compared to the OEM counterparts. All CrossLab supplies are backed by Agilent's 90-day money-back warranty.

Sapphire plunger assembly, 8005-0523 Check valve cartridge replacement kit, 8005-0537

32 Agilent CrossLab HPLC & Electrochemistry Supplies Selection Guide


02_Waters_Layout 1 11/29/12 10:31 AM Page 33

CrossLab Supplies for Waters HPLC Systems

Pump Supplies
Similar to Agilent
OEM CrossLab
Model Description Unit Part No. Part No.
Check Valves and Cartridges
626 LC System Check valve cartridge 1/pk WAT024120 8005-0526
1515 HPLC Pump Check valve cartridge 2/pk 700000254 8005-0513
1525 HPLC Pump
2695 Separations Module
2695D Dissolution Separations Module
2795 Separations Module
510 HPLC Pump
515 HPLC Pump
600 MultiSolvent Delivery System
610 PowerLine Isocratic Pump
LC Module 1
1525 HPLC Pump Check valve cartridge 1/pk 700002399 8005-0508
2695 Separations Module
2695D Dissolution Separations Module
2795 Separations Module
515 HPLC Pump
600 MultiSolvent Delivery System
1515 HPLC Pump Cartridge check valve system 2/pk 700000253 8005-0512
1525 HPLC Pump
515 HPLC Pump
600 MultiSolvent Delivery System
LC Module 1
510 HPLC Pump Outlet check valve rebuild kit, 225 µL 2/pk WAT026014 8005-0528
515 HPLC Pump
600 MultiSolvent Delivery System
610 PowerLine Isocratic Pump
LC Module 1

The cross references to the original equipment manufacturer (OEM) part numbers listed here serve as a recommendation that the Agilent CrossLab products are viable
alternatives to OEM products. CrossLab products are compatible with the corresponding OEM instruments, although in some cases, the CrossLab products may have slightly
different designs as compared to the OEM counterparts. All CrossLab supplies are backed by Agilent's 90-day money-back warranty.

www.agilent.com/chem/CrossLabHPLC 33
02_Waters_Layout 1 11/29/12 10:31 AM Page 34

CrossLab Supplies for Waters HPLC Systems

Detector Supplies
Similar to Agilent
OEM CrossLab
Model Description Unit Part No. Part No.
2996 Photodiode Array Detector Cell gasket 2/pk WAT057924 8005-0532
996 Photodiode Array Detector

Valve Replacement Parts, 1/pk


Similar to Agilent
OEM CrossLab
Model Description Part No. Part No.
2767/2747 Sample Manager Stator, 6 port, stainless steel 700001560 8005-0601
Column/Fluidics Organizer
Rheodyne 7725(i) Injector Vespel rotor seal, for Rheodyne 7725(i) WAT055946 8005-0604
626 LC System Tefzel rotor seal WAT015781 8005-0603
Rheodyne 9125 Injector
2700 Sample Manager Rotor seal WAT272615 8005-0605
2707 Autosampler Rotor seal 700003851 8005-0602

The cross references to the original equipment manufacturer (OEM) part numbers listed here serve as a recommendation that the Agilent CrossLab products are viable
alternatives to OEM products. CrossLab products are compatible with the corresponding OEM instruments, although in some cases, the CrossLab products may have slightly
different designs as compared to the OEM counterparts. All CrossLab supplies are backed by Agilent's 90-day money-back warranty.

Looking for Performance


Maintenance Kits
for Rheodyne Valves?
See page 38.
Vespel rotor seal, for Rheodyne
7725(i), 8005-0604

Tefzel rotor seal, 8005-0603

34 Agilent CrossLab HPLC & Electrochemistry Supplies Selection Guide


02_Waters_Layout 1 11/29/12 10:31 AM Page 35

CrossLab Supplies for Waters HPLC Systems

Sample Loops, 1/pk


Similar to Agilent
OEM CrossLab
Model Volume (µL) Material Part No. Part No.
2690 Separations Module 100 Stainless steel 430001194 8005-0840
2690D Dissolution Separations Module
2695 Separations Module
2695D Dissolution Separations Module
2695 Separations Module 200 Stainless steel 430001630 8005-0841
2695D Dissolution Separations Module
2796 Bioseparations Module 20 PEEK 430000782 8005-0838
2796 Bioseparations Module 100 PEEK 430000783 8005-0839
2707 Autosampler 5 Stainless steel 700000683 8005-0843
CapLC System
CapLC XE System
2707 Autosampler 10 Stainless steel 700003872 8005-0845
2707 Autosampler 20 Stainless steel 700000680 8005-0842
CapLC System
CapLC XE System
2707 Autosampler 50 Stainless steel 700003928 8005-0846
2707 Autosampler 100 Stainless steel 700000685 8005-0844
CapLC System
CapLC XE System

The cross references to the original equipment manufacturer (OEM) part numbers listed here serve as a recommendation that the Agilent CrossLab products are viable
alternatives to OEM products. CrossLab products are compatible with the corresponding OEM instruments, although in some cases, the CrossLab products may have slightly
different designs as compared to the OEM counterparts. All CrossLab supplies are backed by Agilent's 90-day money-back warranty.

www.agilent.com/chem/CrossLabHPLC 35
02_Waters_Layout 1 11/29/12 10:32 AM Page 36

CrossLab Supplies for Waters HPLC Systems

Performance Maintenance Kits


Similar to Agilent
OEM CrossLab
Model Description Kit Contents Part No. Part No.
Performance Maintenance Kits for Separation Modules
2690 Separations Module 2690/95 Contains 2 sapphire plungers, 2 seal wash WAT270944 8005-0915
2690D Dissolution Separations Module Performance plunger seal kits, 2 plunger seals
Maintenance Kit replacements kits (standard, yellow),
2695 Separations Module 4 wash tube seal replacement kits, 1 battery,
2695D Dissolution Separations Module 1 diffuser assembly, 4 face seal replacement
kits, 4 solvent reservoir filters (10 µm),
1 250 µL syringe, 1 precolumn filter insert
assembly, 2 check valve cartridges, 1 seal
pack rebuild kit with needle, 1 wash tube
seal, 1 sealwash tube, 1 PTFE washer, 1 filter
retainer, 1 lower wash seal frit, 1 needlewash
frit, 1 TFE washer, 1 needle assembly,
2 injector seals, 1 stainless steel ferrule
1/16 in, 1 compression screw
2690 Separations Module Seal Pack Rebuild Contains 1 wash tube seal, 1 sealwash tube, WAT271019 8005-0916
2690D Dissolution Separations Module Kit With Needle 1 PTFE washer, 1 filter retainer, 1 lower wash
seal frit, 1 needlewash frit, 1 TFE washer,
2695 Separations Module 1 needle assembly, 2 injector seals, 1 stainless
2695D Dissolution Separations Module steel ferrule 1/16 in, 1 compression screw

(Continued)

The cross references to the original equipment manufacturer (OEM) part numbers listed here serve as a recommendation that the Agilent CrossLab products are viable
alternatives to OEM products. CrossLab products are compatible with the corresponding OEM instruments, although in some cases, the CrossLab products may have slightly
different designs as compared to the OEM counterparts. All CrossLab supplies are backed by Agilent's 90-day money-back warranty.

2960/2965 PM kit, 8005-0915

36 Agilent CrossLab HPLC & Electrochemistry Supplies Selection Guide


02_Waters_Layout 1 11/29/12 10:32 AM Page 37

CrossLab Supplies for Waters HPLC Systems

Performance Maintenance Kits


Similar to Agilent
OEM CrossLab
Model Description Kit Contents Part No. Part No.
Performance Maintenance Kits for Pumps
515 HPLC Pump 515 Pump Contains 2 sapphire plunger assemblies, WAT052587 8005-0913
Performance 2 plunger seals, 1 solvent reservoir filter
Maintenance Kit (10 µm), 1 sparge diffuser, 4 check valve
cartridges
600 MultiSolvent Delivery System 600 Pump Contains 2 sapphire plungers, 2 plunger WAT052675 8005-0930
610 PowerLine Isocratic Pump Performance seals, 4 solvent reservoir filters (10 µm),
Maintenance Kit 4 check valve cartridges, 1 reference valve
rebuild kit, 1 inlet manifold rebuild kit,
4 sparge diffusers
616 LC System 616 LC Contains 2 sapphire plungers, 1 plunger seal WAT052672 8005-0928
Performance kit (ultra high molecular weight polyethylene,
Maintenance Kit yellow), 4 check valve cartridges, 4 sparge
diffusers, 4 solvent reservoir filters (10 µm)
626 LC System 626 LC Contains 2 sapphire plungers, 2 ultra high WAT052673 8005-0929
Performance molecular weight polyethylene plunger seals
Maintenance Kit (yellow), 4 solvent reservoir filters (10 µm),
4 check valve cartridges, 4 sparge diffusers
1515 HPLC Pump 1515 Pump Contains 2 sapphire plungers, 2 plunger 201000113 8005-0925
Performance seals, 4 check valve cartridges, 1 reference
Maintenance Kit valve rebuild kit, 1 solvent reservoir filter
(10 µm)
1525 HPLC Pump 1525 Pump Contains 4 sapphire plungers, 4 plunger 201000114 8005-0926
Performance seals, 8 check valve cartridges, 1 reference
Maintenance Kit valve rebuild kit, 2 solvent reservoir filters
(10 µm)
616 LC System Plunger and Wash Contains parts for both pump heads, WAT031790 8005-0912
626 LC System Seal Rebuild Kit 2 plunger seals, 2 plunger wash seals,
2 retainer seal O-rings, 6 plunger bearings

(Continued)

The cross references to the original equipment manufacturer (OEM) part numbers listed here serve as a recommendation that the Agilent CrossLab products are viable
alternatives to OEM products. CrossLab products are compatible with the corresponding OEM instruments, although in some cases, the CrossLab products may have slightly
different designs as compared to the OEM counterparts. All CrossLab supplies are backed by Agilent's 90-day money-back warranty.

515 pump PM kit, 8005-0913

www.agilent.com/chem/CrossLabHPLC 37
02_Waters_Layout 1 11/29/12 10:32 AM Page 38

CrossLab Supplies for Waters HPLC Systems

Performance Maintenance Kits


Similar to Agilent
OEM CrossLab
Model Description Kit Contents Part No. Part No.
Performance Maintenance Kits for Pumps
1515 HPLC Pump Reference Valve Contains 1 diaphragm for check valve, WAT025746 8005-0911
1525 HPLC Pump Rebuild Kit 1 gasket for check valve, 1 reference
valve button
510 HPLC Pump
515 HPLC Pump
600 MultiSolvent Delivery System
610 PowerLine Isocratic Pump
510 HPLC Pump Outlet Check Valve Contains 2 ball and seat for outlet check WAT026014 8005-0528
515 HPLC Pump Rebuild Kit valves, 2 polychlorotrifluoroethylene (PCTFE)
inserts, 2 stainless steel cup filters (2 µm),
600 MultiSolvent Delivery System 4 large PTFE washers, 2 small PTFE washers
610 PowerLine Isocratic Pump
LC Module 1
510 HPLC Pump Inlet Check Valve Contains 2 ball and seat for inlet check WAT060495 8005-0914
515 HPLC Pump Rebuild Kit valves, 2 retainer gaskets, 2 TFE washers,
2 PTFE washers, 2 PCTFE inserts
600 MultiSolvent Delivery System
610 PowerLine Isocratic Pump
LC Module 1
Performance Maintenance Kits for Autosamplers
717 Autosampler 717 Autosampler Contains 1 seal pack replacement kit, WAT052669 8005-0927
Performance 1 250 µL syringe, 1 filter (2.3 x 11.5 in),
Maintenance Kit 2 filters (2 x 7 in)
Performance Maintenance Kits for Rheodyne Valves
Rheodyne Injector, 3725(i) Performance Contains 1 rotor seal (PEEK), 1 stator face 201000116 8005-0901
Maintenance Kit for assembly (PEEK), 1 isolation seal, 1 needle
Rheodyne 3725(i) guide, 1 needle port cleaner, 1 5/64 in
Injector Valves hex key, 1 9/64 in hex key
Rheodyne Injector, 7010 Performance Contains 1 isolation seal, 1 rotor seal (Vespel), 201000117 8005-0902
Maintenance Kit for 1 5/64 in hex key, 1 9/64 in hex key
Rheodyne 7010
Injector Valves
Rheodyne Injector, 7125 and 7126 Performance Contains 1 rotor seal (Vespel), 1 stator face 201000118 8005-0903
Maintenance Kit for assembly (PEEK/ceramic), 1 isolation seal,
Rheodyne 7125 1 needle guide, 1 needle port cleaner,
and 7126 Injector 1 5/64 in hex key, 1 9/64 in hex key,
Valves instructions

(Continued)

The cross references to the original equipment manufacturer (OEM) part numbers listed here serve as a recommendation that the Agilent CrossLab products are viable
alternatives to OEM products. CrossLab products are compatible with the corresponding OEM instruments, although in some cases, the CrossLab products may have slightly
different designs as compared to the OEM counterparts. All CrossLab supplies are backed by Agilent's 90-day money-back warranty.

38 Agilent CrossLab HPLC & Electrochemistry Supplies Selection Guide


02_Waters_Layout 1 12/4/12 11:04 AM Page 39

CrossLab Supplies for Waters HPLC Systems

Performance Maintenance Kits


Similar to Agilent
OEM CrossLab
Model Description Kit Contents Part No. Part No.
Performance Maintenance Kits for Rheodyne Valves
Rheodyne Injector, 7725(i) Performance Contains 1 stator face assembly 201000119 8005-0904
Maintenance Kit for (PEEK/ceramic), 1 rotor seal (Vespel),
Rheodyne 7725(i) 1 isolation seal, 1 needle guide, 1 needle port
Injector Valves cleaner, 1 5/64 in hex key, 1 9/64 in hex key,
instructions
Rheodyne Injector, 7750E Performance Contains 1 stator face assembly 201000122 8005-0907
Maintenance Kit for (PEEK/ceramic), 1 rotor seal (Vespel),
Rheodyne 7750 1 isolation seal, 1 9/64 in hex key,
Injector Valves instructions
Rheodyne Injector, 7750E-075 Performance Contains 1 rotor seal (PEEK), 1 stator face 201000125 8005-0908
Maintenance Kit assembly (PEEK), 1 isolation seal,
for Rheodyne 1 9/64 in hex key, instructions
7750E-075 Valves
Rheodyne Injector, 8125 and 8126 Performance Contains 1 stator face assembly 201000120 8005-0905
Maintenance Kit for (PEEK/ceramic), 1 rotor seal (PEEK),
Rheodyne 8125 1 isolation seal, 1 needle guide, 1 needle port
and 8126 Injector cleaner, 1 5/64 in hex key, 1 9/64 in hex key,
Valves instructions
Rheodyne Injector, 9125 and 9126 Performance Contains 1 stator face assembly 201000121 8005-0906
Maintenance Kit for (PEEK/ceramic), 1 rotor seal (Tefzel),
Rheodyne 9125 1 isolation seal, 1 needle guide, 1 needle port
and 9126 Injector cleaner, 1 5/64 in hex key, 1 9/64 in hex key,
Valves instructions

The cross references to the original equipment manufacturer (OEM) part numbers listed here serve as a recommendation that the Agilent CrossLab products are viable
alternatives to OEM products. CrossLab products are compatible with the corresponding OEM instruments, although in some cases, the CrossLab products may have slightly
different designs as compared to the OEM counterparts. All CrossLab supplies are backed by Agilent's 90-day money-back warranty.

Rheodyne 7725(i) PM kit, 8005-0904 Rheodyne 9125 PM kit, 8005-0906

www.agilent.com/chem/CrossLabHPLC 39
02_Waters_Layout 1 11/29/12 10:32 AM Page 40

CrossLab Supplies for Waters HPLC Systems

HPLC Capillaries, 1/pk


Similar to Agilent
OD ID Length OEM CrossLab
Model From To Material (mm) (mm) (mm) Fittings Part No. Part No.
2690 Separations Module Pump Autosampler Stainless 1.6 0.23 760 With fittings, WAT270975 8005-0824
2690D Dissolution steel pre-swaged
Separations Module on both ends

2695 Separations Module


2695D Dissolution
Separations Module
2690 Separations Module Autosampler Column Stainless 1.6 0.23 760 With fittings, WAT270979 8005-0825
2690D Dissolution Thermostat steel pre-swaged
Separations Module Valve on both ends

2695 Separations Module


2695D Dissolution
Separations Module
2790 Separations Module
2795 Separations Module
2695 Separations Module Autosampler Column PEEK 1.6 0.13 6000 With fittings, 430000922 8005-0812
2695D Dissolution Thermostat non pre-
Separations Module Valve swaged

(Continued)

CrossLab capillary, stainless steel, 8005-0825 Agilent CrossLab capillary, PEEK, 8005-0812

40 Agilent CrossLab HPLC & Electrochemistry Supplies Selection Guide


02_Waters_Layout 1 11/29/12 10:32 AM Page 41

CrossLab Supplies for Waters HPLC Systems

HPLC Capillaries, 1/pk


Similar to Agilent
OD ID Length OEM CrossLab
Model From To Material (mm) (mm) (mm) Fittings Part No. Part No.
Alliance Column Column Stainless 1.6 0.23 3000 No fittings WAT026973 8005-0823
Thermostat steel
Valve
Column Detector
Alliance Column Column Stainless 1.6 0.508 3000 No fittings WAT026804 8005-0826
Thermostat steel
Valve
Column Detector
Alliance Column Column Stainless 1.6 1.02 3000 No fittings WAT026805 8005-0822
Thermostat steel
Valve
Column Detector
Fittings
Alliance Compression screws and ferrules WAT025604 8005-0835*
*This fitting is used with 8005-0823, 8005-0826, and 8005-0822

CrossLab capillary, stainless steel,


8005-0823

HPLC Fittings, Ferrules, and Unions


Similar to Agilent
OEM CrossLab
Description Unit Part No. Part No.
Compression screw, stainless steel, 1/16 in od 10/pk WAT005070 8005-0837
Compression screws and ferrules 5/pk WAT025604 8005-0835
Union, stainless steel, 1/16 in od 1/pk WAT097332 8005-0836

www.agilent.com/chem/CrossLabHPLC 41
03_Shimadzu_Layout 1 11/29/12 10:34 AM Page 42

CrossLab Supplies for Shimadzu HPLC Systems

CrossLab Supplies for Shimadzu HPLC Systems


Detector Lamps, 1/pk
Similar to Agilent
OEM CrossLab
Model Description Part No. Part No.
SPD-M10Avp Long-life deuterium lamp, 2,000 hours 228-34016-00 8001-0701
Long-life deuterium lamp, 8001-0701
SPD-M20A Tungsten lamp, 1,200 hours 228-34410-91 8001-0703
228-34410-00
SPD-20A/AV Long-life deuterium lamp, 2,000 hours 228-34016-02 8001-0702
SPD-10A/AVvp
SPD-10AV
SPD-20AV Tungsten lamp, 1,200 hours 670-14602-00 8001-0705
Long-life deuterium lamp, 8001-0702
SPD-10AVvp
SPD-10AV
LC-2010 Long-life deuterium lamp, 2,000 hours 228-37401-00 8001-0704
LC-2010HT

Long-life deuterium lamp, 8001-0704

Autosampler Syringes, 1/pk


Agilent Agilent
Similar to Agilent CrossLab CrossLab
OEM CrossLab Replacement Replacement
Model Volume (µL) Description Part No. Syringe Plunger Barrel
SIL-10A 500 Chem (1/4-28 UNF screw threads), gas tight 228-25237-04 8001-0401 8001-0403 8001-0405
SIL-10Ai
SIL-10A 2,500 Chem (1/4-28 UNF screw threads), gas tight 228-25237-06 8001-0402 8001-0406
SIL-10Ai

The cross references to the original equipment manufacturer (OEM) part numbers listed here serve as a recommendation that the Agilent CrossLab products are viable
alternatives to OEM products. CrossLab products are compatible with the corresponding OEM instruments, although in some cases, the CrossLab products may have slightly
different designs as compared to the OEM counterparts. All CrossLab supplies are backed by Agilent's 90-day money-back warranty.

Replacement syringe plunger, 500 µL, 8001-0403 Autosampler syringe, 8001-0401

42 Agilent CrossLab HPLC & Electrochemistry Supplies Selection Guide


03_Shimadzu_Layout 1 11/29/12 10:34 AM Page 43

CrossLab Supplies for Shimadzu HPLC Systems

Pump Supplies, 1/pk


Similar to Agilent
OEM CrossLab
Model Description Part No. Part No.
Plungers and Seals
LC-10ADvp Sapphire plunger 228-35601-92 8001-0503
Sapphire plunger, 8001-0504
LC-2010 (HT) 228-34498-91
LC-20AD Sapphire plunger 228-35601-93 8001-0504
LC-20ADXR
LC-20AB
LC-20AT Sapphire plunger assembly 228-35009-93 8001-0501
LC-2010 Sapphire plunger assembly 228-35281-93 8001-0514
LC-10ATvp Ceramic plunger assembly 228-35009-92 8001-0533
LC-10ADvp Ceramic plunger assembly 228-35601-91 8001-0534
LC-10ADvp Plunger holder 228-35602-91 8001-0515
Sapphire plunger assembly, 8001-0501
LC-20AD/20ADXR/AB
LC-30
LC-10AD/ADvp/LC-600/LC-9A Plunger seal, graphite-filled PTFE 228-35146-00 8001-0502
LC-20AD/AB (GFP)

LC-2010 A/C (HT)


LC-10ATvp Plunger seal, graphite-filled PTFE 228-35145-00 8001-0522
SIL-10ADvp (GFP)

SIL-20A/AC Plunger seal, 8001-0502


LC-20AT
LC-2010 A/C
LC-2010HT
SIL-HT

(Continued)

The cross references to the original equipment manufacturer (OEM) part numbers listed here serve as a recommendation
that the Agilent CrossLab products are viable alternatives to OEM products. CrossLab products are compatible with the
corresponding OEM instruments, although in some cases, the CrossLab products may have slightly different designs as
compared to the OEM counterparts. All CrossLab supplies are backed by Agilent's 90-day money-back warranty.

www.agilent.com/chem/CrossLabHPLC 43
03_Shimadzu_Layout 1 11/29/12 10:34 AM Page 44

CrossLab Supplies for Shimadzu HPLC Systems

Pump Supplies, 1/pk


Similar to Agilent
OEM CrossLab
Model Description Part No. Part No.
Plungers and Seals
LC-20AD/20AB and LC-10ADvp Plunger seal, polyethylene 228-32628-00 8001-0530
LC-10ATvp/10AT/10AS Plunger seal, polyethylene 228-21975-00 8001-0527
LC-10AS/10AT/10ATvp Plunger rinse seal, polyethylene 228-28499-00 8001-0615
LC-20AT Rinse seal 228-35935 8001-0520
LC-20AT Back-up ring for ring seal 228-35934 8001-0516
LC-20AT Plunger seal spacer 228-42700 8001-0510
LC-10AD PTFE diaphragms, 2/pk 228-32784-91 8001-0513
LC-10ADvp
LC-2010
LC-20AD/AB
Check Valves and Cartridges
LC-10AT/ATvp Check valve IN 228-32166-91 8001-0528
LC-10ADvp Check valve IN 228-39093-92 8001-0535
LC-10ADvp/ATvp Check valve OUT 228-34976-91 8001-0532
LC-10AD and LC-600 and LC-9A Check valve IN 228-33492-91 8001-0531
LC-10AT/AD and LC-600 Check valve OUT 228-32531-92 8001-0529
and LC-9A
LC-20AD/AB XR Check valve IN 228-48249-91 8001-0511
228-45557-91
LC-20AD/AB Outlet check valve 228-45705-91 8001-0521
LC-10ADvp/ATvp 228-45563-95
LC-2010 Inlet valve cartridge 228-37149-92 8001-0519
LC-2010HT 228-37149-91
LC-2010 Outlet check valve 228-37147-93 8001-0506
LC-2010HT 228-37147-92
LC-20AT Primary inlet check valve assembly 228-48249-93 8001-0512

The cross references to the original equipment manufacturer (OEM) part numbers listed here serve as a recommendation
that the Agilent CrossLab products are viable alternatives to OEM products. CrossLab products are compatible with the
corresponding OEM instruments, although in some cases, the CrossLab products may have slightly different designs as
compared to the OEM counterparts. All CrossLab supplies are backed by Agilent's 90-day money-back warranty.

44 Agilent CrossLab HPLC & Electrochemistry Supplies Selection Guide


03_Shimadzu_Layout 1 11/29/12 10:34 AM Page 45

CrossLab Supplies for Shimadzu HPLC Systems

Valve Replacement Parts, 1/pk


Similar to Agilent
OEM CrossLab
Model Description Part No. Part No.
SiL-10A/10Ai/10AxL Rotor, 6-port valve 228-21217-91 8001-0601
SIL-10Ai Seal rotor, Vespel, 6-port valve 228-32511-31 8001-0606
SIL-10ADvp Rotor, 6V assembly, stainless steel surround 228-21217-97 8001-0603 Rotor, 6-port valve, 8001-0601
SIL-10ADvp Stator, 6V assembly, ceramic with stainless 228-21220-94 8001-0605
steel surround
SIL-10A/10Ai Stator, 6-port valve 228-21220-91 8001-0604
SiL-10AP Rotor assembly, Vespel, preparative 228-21217-93 8001-0602
SIL-20A/AC Stator, 5-port low pressure valve (LPV) 228-36917-01 8001-0607
LC-2010
SIL-20A/AC Rotor, PEEK, high pressure valve (HPV) 228-41310-92 8001-0612
SIL-HT 228-40750-92
Stator, 6-port valve, 8001-0604
LC-2010 Rotor, Vespel, high pressure valve (HPV) 228-38556-01 8001-0609
SIL-20A/AC High-pressure valve (HPV) stator assembly 228-45408-91 8001-0613
LC-2010 Rotor, PEEK, low pressure valve (LPV) 228-36923-00 8001-0608
LC-2010HT
SIL-20
SIL-HT
LC-10ADvp O-ring for drain valve, perfluoroelastomer 670-11518 8001-0614
LC-10ATvp
SIL-10ADvp PEEK rotor, low pressure valve (LPV),
8001-0608
LC-20AT
LC-2010/HT

The cross references to the original equipment manufacturer (OEM) part numbers listed here serve as a recommendation
that the Agilent CrossLab products are viable alternatives to OEM products. CrossLab products are compatible with the
corresponding OEM instruments, although in some cases, the CrossLab products may have slightly different designs as
compared to the OEM counterparts. All CrossLab supplies are backed by Agilent's 90-day money-back warranty.

Looking for Performance Maintenance Kits


for Rheodyne Valves?
Please see page 38.

www.agilent.com/chem/CrossLabHPLC 45
03_Shimadzu_Layout 1 11/29/12 10:34 AM Page 46

CrossLab Supplies for Shimadzu HPLC Systems

Sample Loops, 1/pk


Similar to Agilent
OEM CrossLab
Model Volume (µL) Material Part No. Part No.
SIL-20A/AC 100 Stainless steel 228-45402-91 8001-0814
228-45402-95
SIL-10ADvp 100 Stainless steel, extended for pre-treatment 228-39751-92 8001-0812
LC-2010 100 Stainless steel 228-41370-91 8001-0809
LD-2010HT 228-37549-91
SIL-HT
100 Stainless steel, 1/16 in 220-90800-20 8001-0801
100 Stainless steel, 1/8 in 220-90800-30 8001-0802

Performance Maintenance Kits


Similar to Agilent
OEM CrossLab
Model Description Kit Contents Part No. Part No.
Performance Maintenance Kits for Pumps
LC-20AD Performance Maintenance Kit Contains 2 graphite-filled PTFE (GFP) plunger seals, 1 stainless 228-45593-91 8001-0901
for LC-20AD steel in-line filter, 1 stainless steel suction filter assembly,
1 plunger holder assembly, 4 stainless steel ferrules 1.6F,
4 stainless steel male nuts 1.6MN for 1/16 in tubing, 4 PEEK
fingertight male nuts for 1/16 in tubing, 1 stainless steel capillary
(1.6 mm od x 0.3 mm id x 2 m)
LC-20AT Performance Maintenance Kit Contains 2 graphite-filled PTFE (GFP) plunger seals, 1 stainless 228-45593-92 8001-0902
for LC-20AT steel in-line filter, 1 stainless steel suction filter assembly,
2 plunger seal spacers, 1 sapphire plunger assembly,
1 rinse seal holder assembly (includes rinse seal, seal holder,
backup ring, and O-ring), 4 stainless steel ferrules 1.6F,
4 stainless steel male nuts 1.6 MN for 1/16 in tubing,
4 PEEK fingertight male nuts for 1/16 in tubing, 1 stainless
steel capillary (1.6 mm od x 0.3 mm id x 2 m)
LC-20AT Rinse seal holder assembly Contains 1 rinse seal, 1 stainless steel rinse seal holder, 228-35946-92 8001-0517
1 back up ring, 1 perfluoroelastomer O-ring for drain valve

(Continued)

The cross references to the original equipment manufacturer (OEM) part numbers listed here serve as a recommendation that the Agilent CrossLab products are viable
alternatives to OEM products. CrossLab products are compatible with the corresponding OEM instruments, although in some cases, the CrossLab products may have slightly
different designs as compared to the OEM counterparts. All CrossLab supplies are backed by Agilent's 90-day money-back warranty.

46 Agilent CrossLab HPLC & Electrochemistry Supplies Selection Guide


03_Shimadzu_Layout 1 12/4/12 11:05 AM Page 47

CrossLab Supplies for Shimadzu HPLC Systems

Performance Maintenance Kits


Similar to Agilent
OEM CrossLab
Model Description Kit Contents Part No. Part No.
Performance Maintenance Kits for Valves
SIL-10ADvp Stator assembly Contains 1 ceramic rotor, 1 stator, 1 housing C manifold 228-36730-91 8001-0610
for SIL-10ADvp with intermediate plate 228-39349-01
228-39755-91
LC-2010 Stator assembly for LC-2010 Contains 1 housing C manifold (stainless steel) packing, 1 stator, 228-40254-91 8001-0509
and pins
Performance Maintenance Kits for Autosamplers
SIL-10ADvp Performance Maintenance Contains 1 6-port injection valve rotor, 1 needle seal (Vespel), 228-39835-91 8001-0903
Kit for SIL-10ADvp 1 stainless steel solvent filter, 1 graphite-filled PTFE (GFP)
plunger seal, 1 stainless steel injection transfer tubing
(0.13 mm id x 200 mL), 3 notch septa, 2 PEEK male nuts,
1 tubing pinch clamp

HPLC Capillaries, 1/pk


Similar to Agilent
OD ID Length OEM CrossLab
Model From To Material (mm) (mm) (mm) Fittings Part No. Part No.
LC-2010 Autosampler Column Flexible 0.6 0.17 200 No fittings 228-38043-91 8001-0810
stainless steel
SIL-10ADvp Injector High pressure Flexible 0.6 0.13 200 With fittings, 228-39756-92 8001-8020
valve port #1 stainless steel non pre-swaged
SIL-10ADvp Pump Autosampler Stainless steel 1.6 0.3 600 No fittings 228-22306-00 8001-0818
SIL-20A/AC
LC-20AP Stainless steel 1.6 0.8 2000 No fittings 228-49820-00 8001-0821
228-50579-43
LC-20AT Stainless steel 1.6 0.3 2000 No fittings 228-36993-96 8001-0822
LC-20AD 228-50579-91
SIL-10ADvp

The cross references to the original equipment manufacturer (OEM) part numbers listed here serve as a recommendation that the Agilent CrossLab products are viable
alternatives to OEM products. CrossLab products are compatible with the corresponding OEM instruments, although in some cases, the CrossLab products may have slightly
different designs as compared to the OEM counterparts. All CrossLab supplies are backed by Agilent's 90-day money-back warranty.

Capillary assembly, flexible stainless steel, 8001-8020

www.agilent.com/chem/CrossLabHPLC 47
03_Shimadzu_Layout 1 11/29/12 10:34 AM Page 48

CrossLab Supplies for Shimadzu HPLC Systems

Tubing
Similar to Agilent
OD ID Length OEM CrossLab
Model Description (mm) (mm) (mm) Fittings Part No. Part No.
LC-2010 ETFE tubing for 1.6 0.8 3000 No fittings 228-18495-01 8001-0807
LC-20AD use between the
inlet block and
the check valve
ETFE tubing for use between the LC-2010 FEP tubing 3 1.5 3000 No fittings 670-10321-05 8001-0823
inlet block and the check valve, 8001-0807 SIl-20A/AC
SPD-20A/AV PEEK tubing 1.6 0.25 500 No fittings 670-10324-01 8001-0824
SPD-M20A 228-33376-50

HPLC Fittings, Ferrules, and Unions


PTFE ferrule, 3.0 F-T, 8001-0803 Similar to Agilent
OEM CrossLab
Model Description Unit Part No. Part No.
LC-2010 PTFE ferrule, 3.0 F-T 1/pk 228-12493-00 8001-0803
LC-20AT Stainless steel ferrule, 1.6 F 1/pk 228-16000-10 8001-0816
LD-20AD
LC-2010 Flangeless nut, M6 1/pk 228-39999-05 8001-0813
Flangeless nut, M6, 8001-0813
SIL-20A/AC Stainless steel male nut, 1.6 MN, 1/pk 228-16001-00 8001-0805
LC-20AT for 1/16 in tubing

LC-20AD
SIL-10ADvp Stainless steel male nut, 1.6 MN, W6 1/pk 228-16001-03 8001-0806
SIL-20A/AC (taller hex portion)

LC-20AD/AB PEEK male nut, 1.6 MN, for plumbing line 1/pk 228-35403-00 8001-0819
Stainless steel male nut, 1.6 MN, LC-10ADvp between inlet block and check valve
for 1/16 in tubing, 8001-0805
PEEK male nut, fingertight for 1/16 in tubing 1/pk 228-18565-84 8001-0817

HPLC In-Line Filters


Similar to Agilent
OEM CrossLab
Model Description Unit Part No. Part No.
Stainless steel male nut, 1.6 MN,
W6 (taller hex portion), 8001-0806 LC-2010 Stainless steel in-line filter 1/pk 228-35871-96 8001-0808
LC-20AD/AB/AT 228-35871-94
LC-10ADvp/ATvp

The cross references to the original equipment manufacturer (OEM) part numbers listed here serve as a recommendation
that the Agilent CrossLab products are viable alternatives to OEM products. CrossLab products are compatible with the
Stainless steel in-line filter, 8001-0808 corresponding OEM instruments, although in some cases, the CrossLab products may have slightly different designs as
compared to the OEM counterparts. All CrossLab supplies are backed by Agilent's 90-day money-back warranty.

48 Agilent CrossLab HPLC & Electrochemistry Supplies Selection Guide


04_Dionex_Layout 1 11/29/12 10:37 AM Page 49

CrossLab Supplies for Dionex HPLC Systems

CrossLab Supplies for Dionex HPLC Systems


Detector Lamps, 1/pk
Similar to Agilent
OEM CrossLab
Model Description Part No. Part No.
VWD-3000 Series Tungsten lamp, 2,000 hours 6074.2000 8002-0705
Long-life deuterium lamp, 8002-0701
MWD-3000 Series
DAD-3000 Series
UVD 170/340 Long-life deuterium lamp, 2,000 hours 5053.1204 8002-0701
UVD 160/320
PDA-100 Tungsten lamp, 5,000 hours 056123T 8002-0706
AD-25

The cross references to the original equipment manufacturer (OEM) part numbers listed here serve as a recommendation
that the Agilent CrossLab products are viable alternatives to OEM products. CrossLab products are compatible with the
corresponding OEM instruments, although in some cases, the CrossLab products may have slightly different designs as
compared to the OEM counterparts. All CrossLab supplies are backed by Agilent's 90-day money-back warranty.

www.agilent.com/chem/CrossLabHPLC 49
04_Dionex_Layout 1 12/4/12 11:06 AM Page 50

CrossLab Supplies for Dionex HPLC Systems

Autosampler Syringes, 1/pk


Agilent CrossLab Agilent
Similar to Agilent Replacement Needle CrossLab
Volume OEM CrossLab (Needle Gauge/ Replacement
Model (µL) Description Part No. Syringe Length (mm)/Tip) Plunger
WPS-3000SL 25 Chem (1/4-28 UNF screw 6822.0001 8002-0405
threads), gas tight
250 Chem (1/4-28 UNF screw 6822.0003 8002-0407
threads), gas tight
ASI-100 100 Removable needle, gas tight 5805.2920 8002-0401* 8002-0413, 22/51/3, 6/pk 8002-0402
8002-0412, 22s/51/3, 6/pk
1,000 Removable needle, gas tight 5805.2940 8002-0403* 8002-0414, 22/51/3, 6/pk 8002-0406
8002-0415, 22s/51/3, 6/pk
2,500 Removable needle, gas tight 5805.2950 8002-0404* 8002-0414, 22/51/3, 6/pk 8002-0408
8002-0415, 22s/51/3, 6/pk
*Needles are sold separately

Autosampler Supplies
Similar to Agilent
OD ID Length Volume OEM CrossLab
Model Material (mm) (mm) (mm) (µL) Fittings Part No. Part No.
Needle Seat Capillaries, 1/pk
WPS-3000SL Stainless steel 0.8 0.12 120 1.35 With fittings, 6820.2407 8002-0808
non pre-swaged
WPS-3000SL Stainless steel 0.8 0.18 120 3.1 With fittings, 6820.2408 8002-0809
non pre-swaged
WPS-3000SL Stainless steel 0.8 0.5 120 24 With fittings, 6820.2409 8002-0810
Semiprep non pre-swaged

The cross references to the original equipment manufacturer (OEM) part numbers listed here serve as a recommendation that the Agilent CrossLab products are viable
alternatives to OEM products. CrossLab products are compatible with the corresponding OEM instruments, although in some cases, the CrossLab products may have slightly
different designs as compared to the OEM counterparts. All CrossLab supplies are backed by Agilent's 90-day money-back warranty.

Chem (1/4-28 UNF screw threads), gas tight, 8002-0405 Removable needle, gas tight, 8002-0401

50 Agilent CrossLab HPLC & Electrochemistry Supplies Selection Guide


04_Dionex_Layout 1 11/29/12 10:37 AM Page 51

CrossLab Supplies for Dionex HPLC Systems

Pump Supplies
Similar to Agilent
OEM CrossLab
Model Description Unit Part No. Part No.
Pistons and Seals
ISO-3100A Piston, sapphire 1/pk 6035.2240 8002-0515
LPG-3400A
LPG-3400AB
LPG-3400M
LPG-3400MB
DGP-3600A
DGP-3600AB
DGP-3600M
DGP-3600MB
HPG-3x00A
HPG-3x00M
ISO-3100SD Piston seal, reversed-phase 2/pk 6040.0304 8002-0502
LPG-3400SD
LPG-3400RS
DGP-3600SD
DGP-3600RS
HPG-3x00SD
HPG-3x00RS
ISO-3100SD Support ring for pistons seals 2/pk 6040.0012 8002-0501
LPG-3400SD
LPG-3400RS
DGP-3600SD
DGP-3600RS
HPG-3x00SD
HPG-3x00RS
UltiMate 3000 pump series Ring seal, DR-8, PTFE 10/pk 2266.0082 8002-0601

(Continued)

The cross references to the original equipment manufacturer (OEM) part numbers listed here serve as a recommendation that the Agilent CrossLab products are viable
alternatives to OEM products. CrossLab products are compatible with the corresponding OEM instruments, although in some cases, the CrossLab products may have slightly
different designs as compared to the OEM counterparts. All CrossLab supplies are backed by Agilent's 90-day money-back warranty.

www.agilent.com/chem/CrossLabHPLC 51
04_Dionex_Layout 1 11/29/12 10:37 AM Page 52

CrossLab Supplies for Dionex HPLC Systems

Pump Supplies
Similar to Agilent
OEM CrossLab
Model Description Unit Part No. Part No.
Check Valves and Cartridges
UltiMate 3000 RS pumps, Check valve cartridge, ceramic 1/pk 6041.2301 8002-0517
optional for SD and BM pumps
ISO-3100A Check valve cartridge, sapphire, biocompatible 1/pk 6035.2300 8002-0516
LPG-3400A 6041.2300
LPG-3400M
LPG-3400MB
LPG-3400AB
DGP-3600A
DGP-3600M
DGP-3600MB
DGP-3600AB
HPG-3x00A
HPG-3x00M
HPG-3200P

The cross references to the original equipment manufacturer (OEM) part numbers listed here serve as a recommendation that the Agilent CrossLab products are viable
alternatives to OEM products. CrossLab products are compatible with the corresponding OEM instruments, although in some cases, the CrossLab products may have slightly
different designs as compared to the OEM counterparts. All CrossLab supplies are backed by Agilent's 90-day money-back warranty.

52 Agilent CrossLab HPLC & Electrochemistry Supplies Selection Guide


04_Dionex_Layout 1 11/29/12 10:37 AM Page 53

CrossLab Supplies for Dionex HPLC Systems

Valve Replacement Parts


Similar to Agilent
OEM CrossLab
Model Description Unit Part No. Part No.
FLM-3x00 Rotor seal, proprietary inert polymer composite, 2-position 10-port 1/pk 6720.0110 8002-0607
C2 switching valve (standard)
FLM-3x00 Rotor seal, polyaryletherketone/PTFE composite, 2-position 10-port 1/pk 6720.0092 8002-0605
C2 switching valve (biocompatible)
FLM-3x00 Stator, stainless steel, 2-position 10-port C2 switching valve (standard) 1/pk 6720.0111 8002-0608
ASI-100 Tefzel rotor seal 1/pk 709.7010.071 8002-0604
ASI-100 Vespel rotor seal 1/pk 709.7010.039 8002-0602
Rheodyne injectors
ASI-100 Stainless steel stator 1/pk 709.7010.040 8002-0603
Rheodyne injectors

The cross references to the original equipment manufacturer (OEM) part numbers listed here serve as a recommendation that the Agilent CrossLab products are viable
alternatives to OEM products. CrossLab products are compatible with the corresponding OEM instruments, although in some cases, the CrossLab products may have slightly
different designs as compared to the OEM counterparts. All CrossLab supplies are backed by Agilent's 90-day money-back warranty.

Tefzel rotor seal, 8002-0604 Vespel rotor seal, 8002-0602 Stainless steel stator, 8002-0603

www.agilent.com/chem/CrossLabHPLC 53
04_Dionex_Layout 1 11/29/12 10:37 AM Page 54

CrossLab Supplies for Dionex HPLC Systems

Sample Loops, 1/pk


Similar to Agilent
OEM CrossLab
Model Description Volume (µL) Material Part No. Part No.
ASI-100 series For 100 µL syringe 100 Stainless steel 5810.3012 8002-0859
ASI-100 For 250 µL syringe 150 Stainless steel 5810.3003 8002-0856
ASI-100T
ASI-100 series For 1000 µL syringe 1000 Stainless steel 5810.3010 8002-0857
ASI-100P For 250 µL syringe 2500 Stainless steel 5810.3011 8002-0858
ASI-100PT
WPS-3000SL Analytical For 100 µL syringe 100 Stainless steel 6820.2406 8002-0807
WPS-3000RS
WPS-3000SL Analytical Standard sample loop 250 Stainless steel 6820.2422 8002-0812
WPS-3000RS

Buffer Loops, 1/pk


Similar to Agilent
OEM CrossLab
Model Volume (µL) Material Part No. Part No.
WPS-3000SL Analytical 100 Stainless steel 6820.2413 8002-0860
WPS-3000RS
WPS-3000SL Semiprep >250 Stainless steel 6820.2421 8002-0811

The cross references to the original equipment manufacturer (OEM) part numbers listed here serve as a recommendation
that the Agilent CrossLab products are viable alternatives to OEM products. CrossLab products are compatible with the
corresponding OEM instruments, although in some cases, the CrossLab products may have slightly different designs as
compared to the OEM counterparts. All CrossLab supplies are backed by Agilent's 90-day money-back warranty.

Looking for Performance Maintenance Kits


for Rheodyne Valves?
Please see page 38.

54 Agilent CrossLab HPLC & Electrochemistry Supplies Selection Guide


04_Dionex_Layout 1 11/29/12 10:37 AM Page 55

CrossLab Supplies for Dionex HPLC Systems

Performance Maintenance Kits


Similar to Agilent
OEM CrossLab
Model Description Kit Contents Part No. Part No.
Performance Maintenance Kits for Pumps
ISO-3100SD Performance Maintenance Kit Contains 1 solvent line filter holder, 6040.1950 8002-0907
for ISO-3100SD pump 1 stainless steel solvent line filter frit (Porosity: 10 µm),
1 silicone tubing (2.80 mm od x 1.30 mm id x 1.5 m L),
1 PharMed tubing for peristaltic pump
(3.2 mm od x 1.6 mm id x 180 mm L), 3 tube
connectors for 1.0-2.0 mm id tubing, 4 piston seals
(reversed-phase), 2 support rings, 1 PTFE O-ring seal
(9 mm x 1.5 mm) for seal wash system, 1 PTFE O-ring
seal (32 mm x 1.5 mm) for seal wash system, 1 check
valve cartridge (sapphire), 1 cap seal for purge valve knob
ISO-3100BM Performance Maintenance Kit Contains 1 solvent line filter holder, 1 PEEK solvent 6042.1950 8002-0917
for ISO-3100BM pump line filter frit (Porosity: 10 µm), 1 silicone tubing
(2.80 mm od x 1.30 mm id x 1.5 m L),
1 PharMed tubing for peristaltic pump
(3.2 mm od x 1.6 mm id x 180 mm L), 3 tube
connectors for 1.0-2.0 mm id tubing, 4 piston seals
(reversed-phase, biocompatible), 2 support rings,
1 PTFE O-ring seal (9 mm x 1.5 mm) for seal wash
system, 1 PTFE O-ring seal (32 mm x 1.5 mm) for seal
wash system, 1 check valve cartridge (sapphire),
1 cap seal for purge valve knob
LPG-3400SD Performance Maintenance Kit Contains 4 solvent line filter holders, 4 stainless steel 6040.1951 8002-0908
for LPG-3400SD pump solvent line filter frits (Porosity: 10 µm), 1 silicone tubing
(2.80 mm od x 1.30 mm id x 1.5m L), 1 PharMed tubing
for peristaltic pump (3.2 mm od x 1.6 mm id x 180 mm L),
3 tube connectors for 1.0-2.0 mm id tubing,
4 piston seals (reversed-phase), 2 support rings,
1 PTFE O-ring seal (9 mm x 1.5 mm) for seal wash
system, 1 PTFE O-ring seal (32 mm x 1.5 mm) for seal
wash system, 1 check valve cartridge (sapphire),
1 cap seal for purge valve knob
LPG-3400RS Performance Maintenance Kit Contains 4 solvent line filter holders, 6040.1954 8002-0911
for LPG-3400RS pump 4 stainless steel solvent line filter frits (Porosity: 10 µm),
1 silicone tubing (2.80 mm od x 1.30 mm id x 1.5 m L),
1 PharMed tubing for peristaltic pump
(3.2 mm od x 1.6 mm id x 180 mm L), 3 tube
connectors for 1.0-2.0 mm id tubing, 4 piston seals
(reversed-phase), 1 PTFE O-ring seal (9 mm x 1.5 mm)
for seal wash system, 1 PTFE O-ring seal
(32 mm x 1.5 mm) for seal wash system, 1 check valve
cartridge (ceramic), 1 cap seal for purge valve knob

(Continued)

The cross references to the original equipment manufacturer (OEM) part numbers listed here serve as a recommendation that the Agilent CrossLab products are viable
alternatives to OEM products. CrossLab products are compatible with the corresponding OEM instruments, although in some cases, the CrossLab products may have slightly
different designs as compared to the OEM counterparts. All CrossLab supplies are backed by Agilent's 90-day money-back warranty.

www.agilent.com/chem/CrossLabHPLC 55
04_Dionex_Layout 1 11/29/12 10:37 AM Page 56

CrossLab Supplies for Dionex HPLC Systems

Performance Maintenance Kits


Similar to Agilent
OEM CrossLab
Model Description Kit Contents Part No. Part No.
Performance Maintenance Kits for Pumps
LPG-3400BM Performance Maintenance Kit Contains 4 solvent line filter holders, 4 PEEK 6042.1951 8002-0918
for LPG-3400BM pump solvent line filter frits (Porosity: 10 µm), 1 silicone tubing
(2.80 mm od x 1.30 mm id x 1.5 m L),
1 PharMed tubing for peristaltic pump
(3.2 mm od x 1.6 mm id x 180 mm L), 3 tube
connectors for 1.0-2.0 mm id tubing, 4 piston seals
(reversed-phase, biocompatible), 2 support rings,
1 PTFE O-ring seal (9 mm x 1.5 mm) for seal wash
system, 1 PTFE O-ring seal (32 mm x 1.5 mm) for seal
wash system, 1 titanium inline filter frit (Porosity: 2 µm),
1 check valve cartridge (sapphire), 1 cap seal for purge
valve knob
DGP-3600SD Performance Maintenance Kit Contains 6 solvent line filter holders, 6040.1952 8002-0909
for DGP-3600SD pump 6 stainless steel solvent line filter frits (Porosity: 10 µm),
1 silicone tubing (2.80 mm od x 1.30 mm id x 1.5 m L),
1 PharMed tubing for peristaltic pump
(3.2 mm od x 1.6 mm id x 180 mm L), 5 tube
connectors for 1.0-2.0 mm id tubing, 8 piston seals
(reversed-phase), 4 support rings, 2 PTFE O-ring seals
(9 mm x 1.5 mm) for seal wash system, 2 PTFE O-ring
seals (32 mm x 1.5 mm) for seal wash system,
2 check valve cartridges (sapphire), 2 cap seals for
purge valve knob
DGP-3600RS Performance Maintenance Kit Contains 6 solvent line filter holders, 6 stainless steel 6040.1955 8002-0912
for DGP-3600RS pump solvent line filter frits (Porosity: 10 µm),
1 silicone tubing (2.80 mm od x 1.30 mm id x 1.5 m L),
1 PharMed tubing for peristaltic pump
(3.2 mm od x 1.6 mm id x 180 mm L), 5 tube
connectors for 1.0-2.0 mm id tubing, 8 piston seals
(reversed-phase), 2 PTFE O-ring seals (9 mm x 1.5 mm)
for seal wash system, 2 PTFE O-ring seals
(32 mm x 1.5 mm) for seal wash system, 2 check valve
cartridges (ceramic), 2 cap seals for purge valve knob
DGP-3600BM Performance Maintenance Kit Contains 6 solvent line filter holders, 6042.1952 8002-0919
for DGP-3600BM pump 6 PEEK solvent line filter frits (Porosity: 10 µm),
1 silicone tubing (2.80 mm od x 1.3 mm id x 1.5 m L),
1 PharMed tubing for peristaltic pump
(3.2 mm od x 1.6 mm id x 180 mm L), 5 tube
connectors for 1.0-2.0 mm id tubing, 8 piston seals
(reversed-phase, biocompatible), 4 support rings,
2 PTFE O-ring seals (9 mm x 1.5 mm) for seal wash
system, 2 PTFE O-ring seals (32 mm x 1.5 mm)
for seal wash system, 2 titanium inline filter frits
(Porosity: 2 µm), 2 check valve cartridges (sapphire),
2 cap seals for purge valve knob

(Continued)

The cross references to the original equipment manufacturer (OEM) part numbers listed here serve as a recommendation that the Agilent CrossLab products are viable
alternatives to OEM products. CrossLab products are compatible with the corresponding OEM instruments, although in some cases, the CrossLab products may have slightly
different designs as compared to the OEM counterparts. All CrossLab supplies are backed by Agilent's 90-day money-back warranty.

56 Agilent CrossLab HPLC & Electrochemistry Supplies Selection Guide


04_Dionex_Layout 1 11/29/12 10:37 AM Page 57

CrossLab Supplies for Dionex HPLC Systems

Performance Maintenance Kits


Similar to Agilent
OEM CrossLab
Model Description Kit Contents Part No. Part No.
Performance Maintenance Kits for Pumps
HPG-3x00SD Performance Maintenance Kit Contains 4 solvent line filter holders, 6040.1953 8002-0910
for HPG-3x00SD pump 4 stainless steel solvent line filter frits
(Porosity: 10 µm), 1 silicone tubing
(2.80 mm od x 1.30 mm id x 1.5 m L),
1 PharMed tubing for peristaltic pump
(3.2 mm od x 1.6 mm id x 180 mm L), 5 tube
connectors for 1.0-2.0 mm id tubing, 8 piston seals
(reversed-phase), 4 support rings, 2 PTFE O-ring
seals (9 mm x 1.5 mm) for seal wash system,
2 PTFE O-ring seals (32 mm x 1.5 mm) for seal wash
system, 2 check valve cartridges (sapphire),
1 cap seal for purge valve knob
HPG-3x00RS Performance Maintenance Kit Contains 4 solvent line filter holders, 4 stainless 6040.1956 8002-0913
for HPG-3x00RS pump steel solvent line filter frits (Porosity: 10 µm),
1 silicone tubing (2.80 mm od x 1.30 mm id x 1.5 m L),
1 PharMed tubing for peristaltic pump
(3.2 mm od x 1.6 mm id x 180 mm L), 5 tube connectors
for 1.0-2.0 mm id tubing, 8 piston seals (reversed-phase),
2 PTFE O-ring seals (9 mm x 1.5 mm) for seal wash
system, 2 PTFE O-ring seals (32 mm x 1.5 mm) for seal
wash system, 2 check valve cartridges (ceramic),
1 cap seal for purge valve knob
ISO-3100A Performance Maintenance Kit Contains 2 solvent line filter holders, 1 stirrer, 6035.1961 8002-0904
LPG-3400A and M for UltiMate 3000 pumps with 1 ECTFE tubing (1.60 mm od x 0.75 mm id x 1 m L),
floating pistons 1 silicone tubing (2.80 mm od x 1.30 mm id x 1.5 m L),
DGP-3600A and M 1 PharMed tubing for peristaltic pump
HPG-3x00 A and M (3.2 mm od x 1.6 mm id x 180 mm L), 2 fittings
(for 1/8 in od tubing, PEEK), 2 solvent line locking rings
(PEEK), 2 solvent line support flanges (PEEK), 2 knurled
head screws (1/4 in-28 for ferrule 1/16 in, PEEK),
1 tube connector for 1.0-2.0 mm id tubing, 2 ferrules
(1/16 in for 1/4 in-28 head screw, PEEK), 4 ring seals
(DR-8), 8 piston seals (reversed-phase), 2 mixing
chamber gaskets, 4 O-rings (22 mm x 2 mm, silicone),
4 pistons (sapphire), 4 inline filter frits (stainless steel;
porosity: 0.5 µm), 4 inline filter frits (stainless steel;
porosity: 10 µm), 8 solvent line filter frits (stainless
steel; porosity: 10 µm), 2 piston support hemispheres,
4 support rings, 2 micro flow ring seals, and 4 check
valve cartridges (sapphire)

(Continued)

The cross references to the original equipment manufacturer (OEM) part numbers listed here serve as a recommendation that the Agilent CrossLab products are viable
alternatives to OEM products. CrossLab products are compatible with the corresponding OEM instruments, although in some cases, the CrossLab products may have slightly
different designs as compared to the OEM counterparts. All CrossLab supplies are backed by Agilent's 90-day money-back warranty.

www.agilent.com/chem/CrossLabHPLC 57
04_Dionex_Layout 1 12/4/12 11:10 AM Page 58

CrossLab Supplies for Dionex HPLC Systems

Performance Maintenance Kits


Similar to Agilent
OEM CrossLab
Model Description Kit Contents Part No. Part No.
Performance Maintenance Kits for Pumps
LPG-3400AB and MB Performance Maintenance Kit Contains 1 ECTFE tubing 6035.1963 8002-0906
DGP-3600AB and MB for UltiMate 3000 pumps (1.6 mm od x 0.75 mm id x 1 m L), 1 silicone tubing
with floating pistons, (2.80 mm od x 1.30 mm id x 1.5 m L),
Biocompatible 1 PharMed tubing for peristaltic pump
(3.2 mm od x 1.6 mm id x 180 mm L), 2 PEEK fittings
for 1/8 in od tubing, 2 solvent line locking rings (PEEK),
2 solvent line support flanges (PEEK),
2 knurled head screws (1/4 in-28 for ferrule 1/16 in,
PEEK), 1 tube connector for 1.0-2.0 mm id tubing,
2 ferrules (1/16 in for 1/4 in-28 head screw, PEEK),
4 ring seals (DR-8), 8 piston seals (reversed-phase),
4 O-rings (22 mm x 2 mm, silicone), 4 pistons
(sapphire), 4 inline filter frits (titanium; Porosity:
10 µm), 4 inline filer frits (PEEK; Porosity: 0.5 µm),
2 solvent line filter holders, 6 solvent line filter frits
(titanium; Porosity: 10 µm), 2 piston support
hemispheres, 4 support rings, 2 micro flow ring seals,
4 check valve cartridges (sapphire), and 2 mixing
chamber gaskets
HPG-3200P Performance Maintenance Kit Contains 1 stirrer, 1 silicone tubing 6035.1962 8002-0905
for HPG-3200P pump (2.80 mm od x 1.30 mm id x 1.5 m L),
1 PharMed tubing for peristaltic pump
(3.2 mm od x 1.6 mm id x 180 mm L), 1 FEP tubing
(4.5 mm od x 3.0 mm id x 2 m L), 1 tube connector
for 1.0-2.0 mm id tubing, 2 tube adaptors
(3.0 mm id 1/4 in-28), 4 ring seals (DR-8),
8 piston seals (reversed-phase, semi-preparative),
2 mixing chamber gaskets, 4 ceramic pistons
(semi-preparative), 4 stainess steel inline filter frits
(Porosity: 10 µm), 2 stainless steel solvent line filters
(Porosity: 10 µm), 4 support rings (semi-preparative),
4 check valve cartridges (sapphire)
ISO-3100A Piston seal/support ring kit, Contains 1 support ring and 2 piston seals 6025.2010A 8002-0923
LPG-3400 A and M reversed-phase

DGP-3600 A and M
HPG-3x00 A and M
LPG-3400AB Piston seal/support ring kit, Contains 1 support ring and 2 piston seals 6025.2012 8002-0901
LPG-3400MB reversed-phase,
biocompatible
DGP-3600AB
DGP-3600MB
ISO-3100BM
LPG-3400BM
DPG-3600BM

(Continued)

The cross references to the original equipment manufacturer (OEM) part numbers listed here serve as a recommendation that the Agilent CrossLab products are viable
alternatives to OEM products. CrossLab products are compatible with the corresponding OEM instruments, although in some cases, the CrossLab products may have slightly
different designs as compared to the OEM counterparts. All CrossLab supplies are backed by Agilent's 90-day money-back warranty.

58 Agilent CrossLab HPLC & Electrochemistry Supplies Selection Guide


04_Dionex_Layout 1 11/29/12 10:37 AM Page 59

CrossLab Supplies for Dionex HPLC Systems

Performance Maintenance Kits


Similar to Agilent
OEM CrossLab
Model Description Kit Contents Part No. Part No.
Performance Maintenance Kits for Pumps
HPG-3200P Piston seal/support ring kit, Contains 1 support ring and 2 piston seals 6030.9010 8002-0902
P680 reversed-phase,
semi-preparative
HPG-3200P Piston seal/support ring kit, Contains 1 support ring and 2 piston seals 6030.9011 8002-0903
P680 normal phase,
semi-preparative
ISO-3100A Piston seal/support ring kit, Contains 1 support ring and 2 piston seals 6025.2011A 8002-0924
LPG-3400A normal phase

LPG-3400M
DGP-3600A
DGP-3600M
HPG-3x00A
HPG-3x00M
ISO-3100SD
LPG-3400SD
DGP-3600SD
HPG-3x00SD
ISO-3100SD PTFE seal kit for rear seal Contains 5 PTFE O-ring seals 9 mm x 1.5 mm, 6040.2208 8002-0915
ISO-3100BM wash system 5 PTFE O-ring seals 32 mm x 1.5 mm

LPG-3400SD
LPG-3400BM
LPG-3400RS
DGP-3600SD
DGP-3600BM
DGP-3600RS
HPG-3x00SD
HPG-3x00RS
HPG-3200BX

(Continued)

The cross references to the original equipment manufacturer (OEM) part numbers listed here serve as a recommendation that the Agilent CrossLab products are viable
alternatives to OEM products. CrossLab products are compatible with the corresponding OEM instruments, although in some cases, the CrossLab products may have slightly
different designs as compared to the OEM counterparts. All CrossLab supplies are backed by Agilent's 90-day money-back warranty.

www.agilent.com/chem/CrossLabHPLC 59
04_Dionex_Layout 1 11/29/12 10:37 AM Page 60

CrossLab Supplies for Dionex HPLC Systems

Performance Maintenance Kits


Similar to Agilent
OEM CrossLab
Model Description Kit Contents Part No. Part No.
Performance Maintenance Kits for Pumps
ISO-3100SD Tubing Kit for Includes 1 silicone tubing 6040.9502 8002-0916
ISO-3100BM Rear Seal Wash System (2.80 mm od x 1.3 mm id x 1.5 m),
1 PharMed tubing for peristaltic pump
LGP-3400SD (3.2 mm od x 1.6 mm id x 180 mm),
LGP-3400RS 7 tube connectors for 1-2 mm id tubing
LGP-3400BM
DGP-3600SD
DGP-3600RS
DGP-3600BM
HPG-3x00SD
HPG-3x00RS
Performance Maintenance Kits for Autosamplers
WPS-3000TBSL Rotor Seal and Stator Face Contains 1 rotor seal and 1 stator face 6722.9014 8002-0611
Autosampler Seal Kit
WPS-3000SL Rotor Seal Kit Contains 2 PEEK rotor seals, 1 9/64 in hex key, 6840.0012 8002-0610
WPS-3000RS instructions

WPS-3000SL Injection volume kit, 250 µL Contains 1 stainless steel sample loop, 250 µL; 1 syringe, 6822.2432 8002-0922
WPS-3000RS 250 µL; and 1 stainless steel buffer loop, > 250 µL

The cross references to the original equipment manufacturer (OEM) part numbers listed here serve as a recommendation that the Agilent CrossLab products are viable
alternatives to OEM products. CrossLab products are compatible with the corresponding OEM instruments, although in some cases, the CrossLab products may have slightly
different designs as compared to the OEM counterparts. All CrossLab supplies are backed by Agilent's 90-day money-back warranty.

Looking for Performance Maintenance Kits


for Rheodyne Valves?
Please see page 38.

60 Agilent CrossLab HPLC & Electrochemistry Supplies Selection Guide


04_Dionex_Layout 1 11/29/12 10:37 AM Page 61

CrossLab Supplies for Dionex HPLC Systems

HPLC Capillaries, 1/pk


Similar to Agilent
OD ID Length OEM CrossLab
Model From To Material (mm) (mm) (mm) Fittings Part No. Part No.
UltiMate 3000 RS Pump Autosampler Flexible 0.6 0.13 450 With 6040.2345 8002-0822
stainless steel fittings, non
pre-swaged
UltiMate 3000 SD Pump Autosampler Flexible 0.6 0.18 450 With 6040.2365 8002-0824
stainless steel fittings, non
pre-swaged
UltiMate 3000 RS Autosampler Column Flexible 0.6 0.13 350 With 6040.2335 8002-0821
Thermostat stainless steel fittings, non
Valve pre-swaged
UltiMate 3000 SD Autosampler Column Flexible 0.6 0.18 350 With 6040.2375 8002-0825
Thermostat stainless steel fittings, non
Valve pre-swaged
UltiMate 3000 Autosampler Column Stainless steel 1.6 0.23 340 With 6820.2418 8002-0837
Thermostat fittings, non
Valve pre-swaged
UltiMate 3000 RS Column Column Flexible 0.6 0.13 550 With 6040.2305 8002-0818
Thermostat stainless steel fittings, non
Valve pre-swaged
UltiMate 3000 RS Pump Autosampler Flexible 0.6 0.18 550 With 6040.2355 8002-0823
UltiMate 3000 SD Column Column stainless steel fittings, non
Thermostat pre-swaged
Valve
UltiMate 3000 RS Column Detector Flexible 0.6 0.13 250 With 6040.2325 8002-0820
stainless steel fittings, non
pre-swaged
UltiMate 3000 SD Column Detector Flexible 0.6 0.18 250 With 6040.2385 8002-0826
stainless steel fittings, non
pre-swaged
UltiMate 3000 Column Detector Stainless steel 1.6 0.13 250 With 6074.2410 8002-0833
fittings, non
pre-swaged
UltiMate 3000 Column Detector PEEK 1.6 0.13 250 With 6074.2415 8002-0834
fittings, non
pre-swaged
UltiMate 3000 Column Detector Stainless steel 1.6 0.23 250 With 6074.2400 8002-0831
fittings, non
pre-swaged

(Continued)

The cross references to the original equipment manufacturer (OEM) part numbers listed here serve as a recommendation that the Agilent CrossLab products are viable
alternatives to OEM products. CrossLab products are compatible with the corresponding OEM instruments, although in some cases, the CrossLab products may have slightly
different designs as compared to the OEM counterparts. All CrossLab supplies are backed by Agilent's 90-day money-back warranty.

CrossLab capillary, stainless steel, 8002-0837

CrossLab capillary, PEEK, 8002-0834


CrossLab capillary, stainless steel, 8002-0833

www.agilent.com/chem/CrossLabHPLC 61
04_Dionex_Layout 1 11/29/12 10:37 AM Page 62

CrossLab Supplies for Dionex HPLC Systems

HPLC Capillaries, 1/pk


Similar to Agilent
OD ID Length OEM CrossLab
Model From To Material (mm) (mm) (mm) Fittings Part No. Part No.
UltiMate 3000 Column Detector PEEK 1.6 0.25 250 With 6074.2405 8002-0832
fittings, non
pre-swaged
UltiMate 3000 RS Flexible 0.6 0.13 150 With 6040.2315 8002-0819
stainless steel fittings, non
pre-swaged
VWD-3100 PEEK 1.6 0.25 2000 No fittings 6251.6001 8002-0835
VWD-3100RS
VWD-3400
VWD-3400RS
DAD-3000
DAD-3000RS
MWD-3000
MWD-3000RS
ISO-3100BM
LPG-3400AB
LPG-3400MB
LPG-3400BM
DPG-3600AB
DPG-3600MB
DPG-3600BM
Summit P680 Pump Autosampler Stainless steel 1.6 0.508 178 With 5030.3020 8002-0816
fittings, non
pre-swaged
Summit ASI-100 Autosampler Column Stainless steel With 6000.0020 8002-0817*
fittings, non
pre-swaged
UVD 170U Column Detector PEEK 1.6 0.5 1000 No fittings 2251.6002 8002-0815
UVD 340U
*CrossLab capillary and fitting kit, for ASI-100 Autosampler, contains 1 stainless steel capillary (0.7 mm id x 1 m), 2 stainless steel capillaries (0.25 mm id x 2 m),
15 10-32UNF stainless steel fittings, 5 10-32UNF stainless steel long fittings, 3 10-32UNF stainless steel extra long fittings, 15 stainless steel ferrules 1/16 in,
and 8 stainless steel long ferrules 1/16 in

The cross references to the original equipment manufacturer (OEM) part numbers listed here serve
as a recommendation that the Agilent CrossLab products are viable alternatives to OEM products.
CrossLab products are compatible with the corresponding OEM instruments, although in some
cases, the CrossLab products may have slightly different designs as compared to the OEM
counterparts. All CrossLab supplies are backed by Agilent's 90-day money-back warranty.

CrossLab capillary and fitting kit, 8002-0817

62 Agilent CrossLab HPLC & Electrochemistry Supplies Selection Guide


04_Dionex_Layout 1 11/29/12 10:37 AM Page 63

CrossLab Supplies for Dionex HPLC Systems

Tubing
Similar to Agilent
OD ID Length OEM CrossLab
Model Description (mm) (mm) (mm) Fittings Part No. Part No.
LPG-3x00 peristaltic pump PharMed biocompatible tubing 3.2 1.6 180 No fittings 6000.5000 8002-0803

HPLC Fittings, Ferrules, and Unions


Similar to Agilent
OEM CrossLab
Model Description Unit Part No. Part No.
UltiMate 3000 Series Blind nut, FS-8 biocompatible 1/pk 6000.0144 8002-0802
6000.0044
WPS-3000(T)SL Ferrule and fitting kit, 6822.0011 8002-0921
WPS-3000(T)SL Semiprep contains 6 ferrules
and 6 long fitting screws
WPS-3000(T)RS Blind nut, FS-8 biocompatible, 8002-0802

HPLC In-Line Filters


Similar to Agilent
OEM CrossLab
Model Description Unit Part No. Part No.
LPG-3400BM In-line filter, 10 µL 1/pk 6042.5014 8002-0805
DGP-3600BM
LPG-3400BM Filter frit for titanium in-line filter, 2 µL 1/pk 6268.0036 8002-0806
DGP-3600BM Filter frit for titanium in-line filter, 2 µL,
8002-0806

The cross references to the original equipment manufacturer (OEM) part numbers listed here serve as a recommendation
that the Agilent CrossLab products are viable alternatives to OEM products. CrossLab products are compatible with the
corresponding OEM instruments, although in some cases, the CrossLab products may have slightly different designs as
compared to the OEM counterparts. All CrossLab supplies are backed by Agilent's 90-day money-back warranty.

www.agilent.com/chem/CrossLabHPLC 63
05_CTC_Layout 1 11/29/12 10:40 AM Page 64

CrossLab Supplies for CTC Analytics HPLC Autosamplers

CrossLab Supplies for CTC Analytics


HPLC Autosamplers
Autosampler Syringes for CTC HTS and HTC PAL
Agilent CrossLab
Agilent CrossLab Replacement
Volume (µL) OD (mm) Description Needle Gauge/Length (mm)/Tip Syringe Part No. Plunger Part No.
10 6.7 Fixed needle 22s/51/3 8010-0440, 1/pk
6.7 Fixed needle, gas tight 22s/51/3 8010-0445, 1/pk 8010-0457, 10/pk
25 7.9 Fixed needle, gas tight 22s/51/3 8010-0441, 1/pk 8010-0458, 10/pk
6.7 Fixed needle, gas tight 22s/51/3 8010-0449, 1/pk 8010-0450, 10/pk
100 6.7 Fixed needle, gas tight 22s/51/3 8010-0442, 1/pk 8010-0459, 10/pk
6.7 Fixed needle, gas tight 22/51/3 8010-0446, 1/pk 8010-0459, 10/pk
250 7.9 Fixed needle, gas tight 22/51/3 8010-0467, 1/pk 8010-0456, 10/pk
500 7.9 Fixed needle, gas tight 22/51/3 8010-0468, 1/pk 8010-0460, 10/pk
1.0 mL 7.9 Fixed needle, gas tight 22/51/3 8010-0443, 1/pk 8010-0455, 1/pk
2.5 mL 7.9 Fixed needle, gas tight 22/51/3 8010-0444, 1/pk 8010-0448, 1/pk

64 Agilent CrossLab HPLC & Electrochemistry Supplies Selection Guide


06_Vials_Layout 1 12/4/12 11:12 AM Page 65

CrossLab Vials and Closures

CrossLab Vials and Closures


The table below illustrates that the Agilent CrossLab vial portfolio is compatible with a wide range of HPLC and GC autosamplers.

CrossLab Vial Compatibility

8 mm 9 mm 15 x 45 mm, 11 mm
Manufacturer Autosampler Screw Top Screw Top 4 mL Crimp Top Headspace
Waters 717 Plus 3
Acquity 3 3 3
Alliance 2690 3 3
CapLC 3 3 3
WISP 3
Shimadzu AOC14/1400 3 3 3
AOC-20 3 3 3
AOC 88/9 3 3 3
AOC-5000 3 3 3 Magnetic
HSS-2B/4B 3
LC 2010 3 3 3
SIL-6A/6B/9A With flange
SIL-10A, SIL-10Ai, SIL-10AxL 3 3
SIL-HT/10ADVP 3 3 3
Thermo Scientific A-200S/AS 150/800/8000 3 3 3
AS 3000/TRACE GC 3 3
ASI-100 3 3 3
SURVEYOR LC 3 3 3
TriPlus 3 3
WPS-3000RS 3 3 3
WPS-3000SL 3 3 3
Bruker, Varian* 8034/8035/8100/8200 3 3 3
9095/9100 3 3 3
CP-8410 3 3 3
Genesis 3
PerkinElmer Autosystem GC/XL/AS-2000 3 3 3 3
Clarus 500/600 3 3
HS16/40 3
Integral 4000 3 3 3
ISS-100/200 3 3 3
LC 600 42 vial tray 3
LC Plus 3 3 3
TurboMatrix 40/110 3
CTC Analytics CombiPal 3 3 3 Magnetic
*Formerly Varian systems, now Bruker products

www.agilent.com/chem/CrossLabHPLC 65
06_Vials_Layout 1 11/29/12 10:41 AM Page 66

CrossLab Vials and Closures

Agilent CrossLab Vial Identification Chart with Recommended Fill Volumes


The Agilent CrossLab vial identification chart below provides a quick reference on vial dimensions, fill volumes, and Agilent CrossLab part
numbers for a variety of vials, along with the recommended closures, for both HPLC and GC autosamplers.

Wide Opening Narrow Opening Wide Opening


Screw Top Vials Screw Top Vials Crimp Top Vials
(9 mm) (8 mm) (11 mm)

Dimensions: 32 mm x 12 mm 32 mm x 12 mm 32 mm x 12 mm 32 mm x 12 mm 32 mm x 12 mm 32 mm x 12 mm 32 mm x 12 mm
Recommended Fill: 1.7 mL 1.3 mL 0.3 mL 1.5 mL 1.7 mL 1.3 mL 0.3 mL
Part Number: 8010-0014 8010-0018 8010-0008 8010-0010 8010-0001 8010-0004 8010-0006
Recommended Cap*: 8010-0086 8010-0086 8010-0086 8010-0061 8010-0050 8010-0050 8010-0050

Wide Opening Snap Top Vials Micro Vials Polypropylene Vials

Dimensions: 32 mm x 12 mm 32 mm x 12 mm 32 mm x 12 mm 32 mm x 12 mm 32 mm x 12 mm 32 mm x 12 mm 32 mm x 12 mm 32 mm x 12 mm 32 mm x 12 mm 32 mm x 12 mm
Recommended Fill: 1.5 mL 1.3 mL 0.8 mL 0.1 mL 250 µL 250 µL 250 µL 250 µL 250 µL 0.7 mL
Part Number: 8010-0023 8010-0028 8010-0153 8010-0154 8010-0155 8010-0158 8010-0160 8010-0161 8010-0162 8010-0159
Recommended Cap*: 8010-0108 8010-0108 8010-0050 8010-0050 8010-0050 8010-0050 8010-0050 8010-0061 8010-0061 8010-0050
Glass Insert Glass Insert

Headspace Vials

Dimensions: 45 mm x 22 mm 45 mm x 22 mm 75 mm x 22 mm 75 mm x 22 mm 75 mm x 22 mm 45 mm x 22 mm 45 mm x 22 mm 75 mm x 22 mm 75 mm x 22 mm
Recommended Fill: 10 mL 10 mL 20 mL 20 mL 20 mL 10 mL 10 mL 20 mL 20 mL
Part Number: 8010-0029 8010-0030 8010-0033 8010-0034 8010-0152 8010-0037 8010-0038 8010-0041 8010-0042
Recommended Cap*: 8010-0116 8010-0116 8010-0116 8010-0116 8010-0116 8010-0119 8010-0119 8010-0119 8010-0119

Specialty Vials Inserts for Wide Opening Vials Inserts for Narrow Opening Vials
(11 mm & 9 mm) (8 mm)

Dimensions: 37 mm x 22 mm 45 mm x 15 mm 37 mm x 22 mm 30 mm x 5.6 mm 31 mm x 5.6 mm 31 mm x 5.6 mm 28 mm x 4.8 mm 31 mm x 4.8 mm 31 mm x 4.8 mm


Recommended Fill: 6 mL 4 mL 6 mL 250 µL 250 µL 200 µL 150 µL 150 µL 150 µL
Part Number: 8010-0151 8010-0020 8010-0022 8010-0131 8010-0132 8010-0136 8010-0124 8010-0125 8010-0126
Recommended Cap*: 8010-0116 8010-0095 8010-0101

66 Agilent CrossLab HPLC & Electrochemistry Supplies Selection Guide


06_Vials_Layout 1 11/29/12 10:41 AM Page 67

CrossLab Vials and Closures

Agilent provides this septa compatibility information as a guide and starting reference point. We realize that chemical compatibility can vary
depending on the concentration of the solvent, temperature, molecular weight of the solvent, and other factors. Therefore, it is always
recommended that you try a variety of septa to determine the best one for your analysis.

Vial Septum Chemical Compatibility Chart

PTFE/ PTFE/
PTFE PTFE/Silicone Silicone/PTFE* Red Rubber Viton PTFE/Butyl
Acetonitrile 3 3 3 3 3
Hydrocarbons
(hexane, heptane, methane) 3 3 3 3

Methanol 3 3 3 3 3
Benzene 3 3 3
THF 3 3
Toluene 3 3
DMF 3 3 3 3
DMSO 3 3 3 3
Ether 3 3 3
Chlorinated Solvents
(methylene chloride) 3 3 3

Alcohols (ethanol) 3 3 3 3 3 3
Acetic Acid 3 3 3 3
Acetone 3 3 3
Phenol 3 3 3 3 3
Cyclohexane 3 3 3 3
*PTFE/silicone/PTFE has the same chemical compatibility of PTFE ONLY UNTIL PUNCTURED

www.agilent.com/chem/CrossLabHPLC 67
06_Vials_Layout 1 11/29/12 10:42 AM Page 68

CrossLab Vials and Closures

Vial Cap and Septum Compatibility

High
PTFE/ PTFE/ Performance
Thin PTFE PTFE/Silicone* Silicone/PTFE* Red Rubber Viton Butyl Septa
Temperature Up to 300 °C
Up to 260 °C -40 °C to 200 °C -40 °C to 200 °C -40 °C to 90 °C -40 °C to 260 °C -50 °C to 150 °C
range for up to 1 hour
Use for
multiple No Yes Yes No No No Yes
injections
Price Very economical Economical Most expensive Very economical Economical Economical More expensive
Resistance to
None Excellent Excellent None None None Excellent
coring

Recommended
No Yes Yes No No No No
for storage

Best for Superior Most common Superior Chlorosilanes, Chlorinated Organic High temperature
chemical HPLC and GC performance for more economical solvents, higher solvents, headspace
inertness, short analyses, not as ultra trace option for single temperatures acetic acids; applications
cycle times, resistant to analysis, repeat injections impermeable
and single coring as P/S/P injections, to gases
injections internal
standards
*Agilent CrossLab silicone is platinum cured (versus peroxide cured), making it more inert and less likely to interact with samples

68 Agilent CrossLab HPLC & Electrochemistry Supplies Selection Guide


06_Vials_Layout 1 11/29/12 10:42 AM Page 69

CrossLab Vials and Closures

CrossLab Screw Top Vials and Closures


Combine the excellent autosampler handling of a crimp cap profile with the ease of a screw cap.
CrossLab screw caps and precision-fit septa give a secure seal with microvolume inserts.

2 mL Wide Opening (9 mm) Screw Top Vials and Closures


• 2 mL, 12 x 32 mm, 9 mm diameter
• Available in unique packaging designed to reduce vial breakage
• Wider opening prevents syringe problems
• Unique thread design for consistently secure seal
• Precision-formed neck for optimal robotic arm handling
• Optional ceramic write-on spot with fill marks

2 mL Wide Opening (9 mm) Screw Top Glass Vials


Agilent CrossLab
Description Unit Part No.
Clear 100/pk 8010-0015
Clear, write-on spot 100/pk 8010-0014 Clear, 2 mL wide opening (9 mm) screw top
1000/cs 8010-0175 glass vials, 8010-0015
Amber 100/pk 8010-0017
Amber, write-on spot 100/pk 8010-0016
1000/cs 8010-0176
Screw Top Vials with Fixed Inserts
Clear, 300 µL insert volume 100/pk 8010-0008
Amber, 300 µL insert volume 100/pk 8010-0009

Wide opening screw top vials with write-on


To obtain an optimal fit and seal of any vial and closure, we strongly recommend buying an entire CrossLab vial assembly spot, 8010-0014
(including a vial, cap, and septum, as well as a vial insert if needed). Please avoid mixing and matching any CrossLab vials
with any other brand of closures, or any CrossLab closures with any other brand of vials.

For additional help in selecting vials, caps, and septa,


go to www.agilent.com/chem/SelectVials

www.agilent.com/chem/CrossLabHPLC 69
06_Vials_Layout 1 11/29/12 10:42 AM Page 70

CrossLab Vials and Closures

Screw Caps for Wide Opening (9 mm) Vials


Agilent CrossLab
Color Septa Type Unit Part No.
Blue PTFE/silicone 100/pk 8010-0086
PTFE/silicone/PTFE 100/pk 8010-0087
Pre-slit PTFE/silicone 100/pk 8010-0078
Bonded PTFE/silicone 100/pk 8010-0077
PTFE lined 100/pk 8010-0080
Open top, no septa 100/pk 8010-0079
Red PTFE/silicone 100/pk 8010-0088
PTFE/silicone/PTFE 100/pk 8010-0089
Pre-slit PTFE/silicone 100/pk 8010-0082
Bonded PTFE/silicone 100/pk 8010-0081
Open top, no septa 100/pk 8010-0083
Orange PTFE/silicone 100/pk 8010-0084
1000/cs 8010-0186
Orange screw caps with PTFE/silicone septa PTFE/silicone/PTFE 100/pk 8010-0085
for wide opening (9 mm) vials, 8010-0084
1000/cs 8010-0187
Pre-slit PTFE/silicone 100/pk 8010-0075
Bonded PTFE/silicone 100/pk 8010-0074
Open top, no septa 100/pk 8010-0076

Septa for Wide Opening (9 mm) Screw Caps


Agilent CrossLab
Septa Type Color Unit Part No.
PTFE/red silicone Ivory 100/pk 8010-0093
PTFE/white silicone/red PTFE Red 100/pk 8010-0091
1000/cs 8010-0188
Pre-slit PTFE/white silicone Blue 100/pk 8010-0094
Septa for wide opening screw caps, PTFE/white silicone Red 100/pk 8010-0092
8010-0094

To obtain an optimal fit and seal of any vial and closure, we strongly recommend buying an entire CrossLab vial assembly
(including a vial, cap, and septum, as well as a vial insert if needed). Please avoid mixing and matching any CrossLab vials
with any other brand of closures, or any CrossLab closures with any other brand of vials.

70 Agilent CrossLab HPLC & Electrochemistry Supplies Selection Guide


06_Vials_Layout 1 11/29/12 10:42 AM Page 71

CrossLab Vials and Closures

2 mL Wide Opening (9 mm) Screw Top Vial Convenience Packs, 100/pk


Agilent
CrossLab
Vial Type Septa Type Cap Color Part No.
Clear Pre-slit PTFE/silicone Red 8010-0425
Clear, write-on spot PTFE/silicone Orange 8010-0198
Clear, write-on spot Pre-slit PTFE/silicone Orange 8010-0542
Clear, write-on spot, 300 µL insert volume PTFE/silicone Orange 8010-0545
Clear, write-on spot, 300 µL insert volume Pre-slit PTFE/silicone Orange 8010-0547
CrossLab vial kit, screw top,
Amber, write-on spot PTFE/silicone Orange 8010-0199 clear with write-on spot,
Amber, write-on spot Pre-slit PTFE/silicone Orange 8010-0543 300 µL insert volume, orange cap,
Amber, write-on spot, 300 µL insert volume PTFE/silicone Orange 8010-0546 pre-slit PTFE/silicone septa, 8010-0547

Amber, write-on spot, 300 µL insert volume Pre-slit PTFE/silicone Orange 8010-0548

To obtain an optimal fit and seal of any vial and closure, we strongly recommend buying an entire CrossLab vial assembly
(including a vial, cap, and septum, as well as a vial insert if needed). Please avoid mixing and matching any CrossLab vials
with any other brand of closures, or any CrossLab closures with any other brand of vials.

For additional help in selecting vials, caps, and septa,


go to www.agilent.com/chem/SelectVials

www.agilent.com/chem/CrossLabHPLC 71
06_Vials_Layout 1 11/29/12 10:42 AM Page 72

CrossLab Vials and Closures

2 mL Standard Opening (8 mm) Screw Top Vials and Closures


• 2 mL, 12 x 32 mm, 8 mm diameter
• 8-425 thread design
• Optional ceramic write-on spot with fill marks

2 mL Standard Opening (8 mm) Screw Top Glass Vials


Agilent
CrossLab
Description Unit Part No.
Clear 100/pk 8010-0011
Clear, write-on spot 100/pk 8010-0010
Amber 100/pk 8010-0013
Clear 2 mL standard opening (8 mm) Amber, write-on spot 100/pk 8010-0012
screw top glass vials, 8010-0011

2 mL Standard Opening (8 mm) Screw Top Glass Vial Convenience Packs


Agilent
CrossLab
Vial Type Septa Type Cap Color Unit Part No.
Clear PTFE/silicone Black 100/pk 8010-0414
Clear PTFE/butyl Black 100/pk 8010-0426
Clear, 100 µL insert volume PTFE/butyl Black 100/pk 8010-0427
Amber PTFE/silicone Black 100/pk 8010-0415

To obtain an optimal fit and seal of any vial and closure, we strongly recommend buying an entire CrossLab vial assembly
(including a vial, cap, and septum, as well as a vial insert if needed). Please avoid mixing and matching any CrossLab vials
with any other brand of closures, or any CrossLab closures with any other brand of vials.

For additional help in selecting vials, caps, and septa,


go to www.agilent.com/chem/SelectVials

72 Agilent CrossLab HPLC & Electrochemistry Supplies Selection Guide


06_Vials_Layout 1 11/29/12 10:42 AM Page 73

CrossLab Vials and Closures

Screw Caps for Standard Opening (8 mm) Vials


Agilent
CrossLab
Color Septa Type Unit Part No.
Blue PTFE/silicone 100/pk 8010-0061
Pre-slit PTFE/silicone 100/pk 8010-0062
PTFE/silicone/PTFE 100/pk 8010-0063
PTFE/butyl 100/pk 8010-0064
Open top, no septa 100/pk 8010-0065
Red PTFE/silicone 100/pk 8010-0066
Pre-slit PTFE/silicone 100/pk 8010-0067
PTFE/silicone/PTFE 100/pk 8010-0068
PTFE/butyl 100/pk 8010-0069
Open top, no septa 100/pk 8010-0070
Orange PTFE/silicone 100/pk 8010-0056
Pre-slit PTFE/silicone 100/pk 8010-0057
Orange screw caps with PTFE/silicone septa
PTFE/silicone/PTFE 100/pk 8010-0058 for standard opening vials, 8010-0056
PTFE/butyl 100/pk 8010-0059
Open top, no septa 100/pk 8010-0060
Black PTFE/silicone 100/pk 8010-0054
Open top, no septa 100/pk 8010-0055
Flanged Caps (Compatible with Shimadzu Autosamplers)
Orange Flanged, PTFE/silicone 100/pk 8010-0141
Flanged, pre-slit PTFE/silicone 100/pk 8010-0142
Flanged, no septa 100/pk 8010-0166

Septa for Standard Opening (8 mm) Vials


Agilent
CrossLab
Septa Type Unit Part No.
Red PTFE/white silicone/red PTFE 100/pk 8010-0071
Red PTFE/white silicone 100/pk 8010-0072
PTFE/butyl 500/pk 8010-0073

To obtain an optimal fit and seal of any vial and closure, we strongly recommend buying an entire CrossLab vial assembly
(including a vial, cap, and septum, as well as a vial insert if needed). Please avoid mixing and matching any CrossLab vials
with any other brand of closures, or any CrossLab closures with any other brand of vials.

www.agilent.com/chem/CrossLabHPLC 73
06_Vials_Layout 1 11/29/12 10:42 AM Page 74

CrossLab Vials and Closures

4 mL (13 mm) Screw Top Vials and Closures


• 4 mL, 15 x 45 mm
• Compatible with WISP 48 style autosamplers
• Precision-formed screw threads (13 x 425) for consistently secure seal
• Can be used as wash, waste, or storage vials

4 mL (13 mm) Screw Top Glass Vials


Agilent
CrossLab
Description Unit Part No.
Clear 100/pk 8010-0020
Amber 100/pk 8010-0021

Screw Caps for 4 mL (13 mm) Vials


Agilent
CrossLab
Color Septa Type Unit Part No.
Black Red PTFE/silicone 100/pk 8010-0095
Black screw caps with red PTFE/silicone Open top, no septa 100/pk 8010-0096
septa for 4 mL (13 mm) vials, 8010-0095

To obtain an optimal fit and seal of any vial and closure, we strongly recommend buying an entire CrossLab vial assembly
(including a vial, cap, and septum, as well as a vial insert if needed). Please avoid mixing and matching any CrossLab vials
with any other brand of closures, or any CrossLab closures with any other brand of vials.

74 Agilent CrossLab HPLC & Electrochemistry Supplies Selection Guide


06_Vials_Layout 1 11/29/12 10:42 AM Page 75

CrossLab Vials and Closures

Septa for 4 mL (13 mm) Vials


Agilent
CrossLab
Septa Type Unit Part No.
Red PTFE/white silicone 100/pk 8010-0098
White PTFE 100/pk 8010-0099
Pre-slit PTFE/silicone 100/pk 8010-0557

4 mL (13 mm) Screw Top Vial Convenience Packs, 100/pk


Agilent
Cap CrossLab
Vial Type Septa Type Color Part No.
Clear PTFE/silicone Black 8010-0553
Clear Pre-slit PTFE/silicone Black 8010-0555
Clear, 250 µL insert volume PTFE/silicone Black 8010-0559
Clear, 250 µL insert volume Pre-slit PTFE/silicone Black 8010-0561
Amber PTFE/silicone Black 8010-0554
Amber Pre-slit PTFE/silicone Black 8010-0556
Amber, 250 µL insert volume PTFE/silicone Black 8010-0560
CrossLab vial kit, screw top, clear,
Amber, 250 µL insert volume Pre-slit PTFE/silicone Black 8010-0562 250 µL insert volume, black cap,
pre-slit PTFE/silicone septa, 8010-0561

To obtain an optimal fit and seal of any vial and closure, we strongly recommend buying an entire CrossLab vial assembly
(including a vial, cap, and septum, as well as a vial insert if needed). Please avoid mixing and matching any CrossLab vials
with any other brand of closures, or any CrossLab closures with any other brand of vials.

For additional help in selecting vials, caps, and septa,


go to www.agilent.com/chem/SelectVials

www.agilent.com/chem/CrossLabHPLC 75
06_Vials_Layout 1 11/29/12 10:42 AM Page 76

CrossLab Vials and Closures

6 mL (16 mm) Screw Top Vials and Closures

6 mL (16 mm) Screw Top Glass Vials


Screw caps for 6 mL (16 mm) vials
Agilent
CrossLab
Description Unit Part No.
Clear 100/pk 8010-0022

Screw caps for 6 mL (16 mm) vials


Agilent
CrossLab
Septa Type Unit Part No.
PTFE/silicone 100/pk 8010-0101
Pre-slit PTFE/silicone 100/pk 8010-0102
Open top, no septa 100/pk 8010-0100

To obtain an optimal fit and seal of any vial and closure, we strongly recommend buying an entire CrossLab vial assembly
(including a vial, cap, and septum, as well as a vial insert if needed). Please avoid mixing and matching any CrossLab vials
with any other brand of closures, or any CrossLab closures with any other brand of vials.

For additional help in selecting vials, caps, and septa,


go to www.agilent.com/chem/SelectVials

76 Agilent CrossLab HPLC & Electrochemistry Supplies Selection Guide


06_Vials_Layout 1 11/29/12 10:42 AM Page 77

CrossLab Vials and Closures

10 mL (22 mm) Screw Top Vials and Closures

10 mL (22 mm) Screw Top Glass Vials


Agilent
CrossLab
Description Unit Part No.
Clear 100/pk 8010-0563

CrossLab vial, screw top, 10 mL, 22 mm,


Screw Caps for 10 mL (22 mm) Vials clear, 8010-0563

Agilent
CrossLab
Septa Type Color Unit Part No.
No septa Black 100/pk 8010-0565

Septa for 10 mL (22 mm) Vials


Agilent
CrossLab
Septa Type Unit Part No.
PTFE/silicone 100/pk 8010-0564

To obtain an optimal fit and seal of any vial and closure, we strongly recommend buying an entire CrossLab vial assembly
(including a vial, cap, and septum, as well as a vial insert if needed). Please avoid mixing and matching any CrossLab vials
with any other brand of closures, or any CrossLab closures with any other brand of vials.

www.agilent.com/chem/CrossLabHPLC 77
06_Vials_Layout 1 11/29/12 10:42 AM Page 78

CrossLab Vials and Closures

CrossLab Crimp Top Vials and Closures


The wide opening crimp cap provides a larger target area for improved autosampler needle accuracy.
Select from a variety of cap colors and septa. Whatever your crimp top vial needs, Agilent has what
you are looking for.

2 mL (11 mm) Crimp Top Vials and Closures


• 2 mL, 12 x 32 mm
• Available in unique packaging designed to reduce vial breakage
• Tightly controlled crown for improved crimping
• Precision-formed neck for improved autosampler handling
• Rigorous quality assurance provides dimensional accuracy from lot to lot
• Optional ceramic write-on spot with fill marks

2 mL (11 mm) Crimp Top Glass Vials


Crimp top glass vials with write-on spot,
8010-0001
Agilent
CrossLab
Description Unit Part No.
Clear 100/pk 8010-0002
Clear, write-on spot 100/pk 8010-0001
1000/cs 8010-0170
Amber, write-on spot 100/pk 8010-0003
1000/cs 8010-0172
Crimp Top Vials with Fixed Inserts
Clear, 300 µL insert volume 100/pk 8010-0006
Amber, 300 µL insert volume 100/pk 8010-0007

To obtain an optimal fit and seal of any vial and closure, we strongly recommend buying an entire CrossLab vial assembly
(including a vial, cap, and septum, as well as a vial insert if needed). Please avoid mixing and matching any CrossLab vials
with any other brand of closures, or any CrossLab closures with any other brand of vials.

TIPS & TOOLS


Agilent offers ergonomic manual crimpers and decappers, designed to significantly reduce
hand strain. Electronic versions are also available, featuring a longer life battery designed for
quick, powerful use. For more information, please visit www.agilent.com/chem/crimper

78 Agilent CrossLab HPLC & Electrochemistry Supplies Selection Guide


06_Vials_Layout 1 11/29/12 10:42 AM Page 79

CrossLab Vials and Closures

Crimp Caps with 11 mm Septa


Agilent
CrossLab
Cap Color Septa Type Unit Part No.
Silver aluminum PTFE/silicone/PTFE 100/pk 8010-0049
1000/cs 8010-0182
PTFE/silicone 100/pk 8010-0050
1000/cs 8010-0183
Pre-slit PTFE/Silicone 100/pk 8010-0582
PTFE/butyl 100/pk 8010-0051
Thin membrane rubber 25/pk 8010-0053
PTFE/red rubber 100/pk 8010-0045
1000/cs 8010-0181
Blue aluminum PTFE/red rubber 100/pk 8010-0046
Green aluminum PTFE/red rubber 100/pk 8010-0047
Red aluminum PTFE/red rubber 100/pk 8010-0048
Gold aluminum Magnetic 100/pk 8010-0052
Magnetic crimp caps, 8010-0052

To obtain an optimal fit and seal of any vial and closure, we strongly recommend buying an entire CrossLab vial assembly
(including a vial, cap, and septum, as well as a vial insert if needed). Please avoid mixing and matching any CrossLab vials
with any other brand of closures, or any CrossLab closures with any other brand of vials.

For additional help in selecting vials, caps, and septa,


go to www.agilent.com/chem/SelectVials

TIPS & TOOLS


Red rubber septa have a tendency to cause needle sticking during sampling and are more likely to core. Agilent recommends using silicone
septa as a higher quality alternative to prevent contamination and issues related to septa coring.

www.agilent.com/chem/CrossLabHPLC 79
06_Vials_Layout 1 11/29/12 10:42 AM Page 80

CrossLab Vials and Closures

2 mL (11 mm) Crimp Top Vial Convenience Packs, 100/pk


Agilent
CrossLab
Vial Type Septa Type Cap Color Part No.
Clear, write-on spot PTFE/silicone Silver aluminum 8010-0195
Clear, write-on spot, 300 µL insert volume, PTFE/silicone Silver aluminum 8010-0566
conical with feet
Clear, write-on spot, 300 µL insert volume, Pre-slit PTFE/silicone Silver aluminum 8010-0568
conical with feet
Amber, write-on spot PTFE/silicone Silver aluminum 8010-0196
Amber, write-on spot, 300 µL insert volume, PTFE/silicone Silver aluminum 8010-0567
conical with feet
Amber, write-on spot, 300 µL insert volume, Pre-slit PTFE/silicone Silver aluminum 8010-0569
CrossLab crimp top vial kit, amber
conical with feet
with write-on spot, 3000 µL insert volume,
conical with feet, silver aluminum cap,
pre-slit PTFE/silicone septa, 8010-0569

To obtain an optimal fit and seal of any vial and closure, we strongly recommend buying an entire CrossLab vial assembly
(including a vial, cap, and septum, as well as a vial insert if needed). Please avoid mixing and matching any CrossLab vials
with any other brand of closures, or any CrossLab closures with any other brand of vials.

For additional help in selecting vials, caps, and septa,


go to www.agilent.com/chem/SelectVials

80 Agilent CrossLab HPLC & Electrochemistry Supplies Selection Guide


06_Vials_Layout 1 11/29/12 10:42 AM Page 81

CrossLab Vials and Closures

Crimp Top Micro Vials


Agilent CrossLab offers a selection of crimp top micro vials designed for a variety of autosamplers,
including HTS and HTC PAL systems, to cope with today's high-throughput LC/MS demands.
Additionally, Agilent CrossLab crimp top micro vials work seamlessly with CombiPAL and GC PAL
magnetic needle guides and barcode readers.

Crimp Top Micro Vials


Agilent
CrossLab
Description Volume Unit Part No.
Amber, flat bottom 0.8 mL 1000/cs 8010-0153
Clear, tapered bottom 0.1 mL 500/pk 8010-0154
Amber, flat bottom crimp top micro vials,
Clear, rounded bottom 0.3 mL 500/pk 8010-0155
8010-0153

To obtain an optimal fit and seal of any vial and closure, we strongly recommend buying an entire CrossLab vial assembly
(including a vial, cap, and septum, as well as a vial insert if needed). Please avoid mixing and matching any CrossLab vials
with any other brand of closures, or any CrossLab closures with any other brand of vials.

www.agilent.com/chem/CrossLabHPLC 81
06_Vials_Layout 1 11/29/12 10:42 AM Page 82

CrossLab Vials and Closures

CrossLab Snap Top Vials and Closures


Snap top vials and caps are the simple, efficient way to a secure seal without crimping. It's as easy as
push-on, pull-off. Crimp caps can also be used with wide opening snap top vials.

Note: Snap cap vials cannot be pressurized.

2 mL (11 mm) Snap Top Vials and Closures


• 2 mL, 12 x 32 mm
• Use with any 11 mm snap or crimp cap
• Available in unique packaging designed to reduce vial breakage
• Precision-formed neck improves autosampler handling
• Optional ceramic write-on spot

2 mL (11 mm) Snap Top Glass Vials


Agilent
CrossLab
Description Unit Part No.
Clear 100/pk 8010-0024
Clear, write-on spot 100/pk 8010-0023
1000/cs 8010-0177
Amber 100/pk 8010-0026
Snap top vials with write-on spot, Amber, write-on spot 100/pk 8010-0025
8010-0025 1000/cs 8010-0178

To obtain an optimal fit and seal of any vial and closure, we strongly recommend buying an entire CrossLab vial assembly
(including a vial, cap, and septum, as well as a vial insert if needed). Please avoid mixing and matching any CrossLab vials
with any other brand of closures, or any CrossLab closures with any other brand of vials.

82 Agilent CrossLab HPLC & Electrochemistry Supplies Selection Guide


06_Vials_Layout 1 11/29/12 10:42 AM Page 83

CrossLab Vials and Closures

Snap Caps with 11 mm Septa


Agilent
CrossLab
Cap Color Septa Type Unit Part No.
Clear PTFE/red silicone 100/pk 8010-0104
PTFE/silicone/PTFE 100/pk 8010-0105
Pre-slit PTFE/white silicone 100/pk 8010-0106
Clear polyethylene membrane 100/pk 8010-0107 Orange snap caps with PTFE/red silicone
Blue PTFE/red silicone 100/pk 8010-0108 11 mm septa, 8010-0103
PTFE/white silicone 100/pk 8010-0112
Green PTFE/red silicone 100/pk 8010-0109
Orange PTFE/red silicone 100/pk 8010-0103
PTFE/red silicone 1000/cs 8010-0189
PTFE/white silicone 100/pk 8010-0111
Pre-slit PTFE/white silicone 1000/cs 8010-0190
Pre-slit PTFE/white silicone 100/pk 8010-0113
Red PTFE/red silicone 100/pk 8010-0110
Polyurethane 100/pk 8010-0115

2 mL (11 mm) Snap Top Vial Convenience Packs


Agilent
CrossLab
Vial Type Septa Type Cap Color Unit Part No.
Clear, write-on spot PTFE/silicone Orange 100/pk 8010-0200
Amber, write-on spot PTFE/silicone Orange 100/pk 8010-0411

To obtain an optimal fit and seal of any vial and closure, we strongly recommend buying an entire CrossLab vial assembly
(including a vial, cap, and septum, as well as a vial insert if needed). Please avoid mixing and matching any CrossLab vials
with any other brand of closures, or any CrossLab closures with any other brand of vials.

For additional help in selecting vials, caps, and septa,


go to www.agilent.com/chem/SelectVials

www.agilent.com/chem/CrossLabHPLC 83
06_Vials_Layout 1 11/29/12 10:42 AM Page 84

CrossLab Vials and Closures

Snap Top Solvent Vial Convenience Packs


Snap Top Solvent Vial Convenience Packs
Agilent
CrossLab
Vial Type Septa Type Cap Color Unit Part No.
5 mL Snap Top Solvent Vial Convenience Pack
Clear PTFE/silicone Clear 100/pk 8010-0416
10 mL Snap Top Solvent Vial Convenience Pack
Clear Red PTFE/white silicone Clear 100/pk 8010-0422

Snap Cap for 5 mL and 10 mL Solvent Vials


Agilent
CrossLab
Cap Color Septa Type Unit Part No.
Clear PTFE/silicone 50/pk 8010-0423

To obtain an optimal fit and seal of any vial and closure, we strongly recommend buying an entire CrossLab vial assembly
(including a vial, cap, and septum, as well as a vial insert if needed). Please avoid mixing and matching any CrossLab vials
with any other brand of closures, or any CrossLab closures with any other brand of vials.

For additional help in selecting vials, caps, and septa,


go to www.agilent.com/chem/SelectVials

84 Agilent CrossLab HPLC & Electrochemistry Supplies Selection Guide


06_Vials_Layout 1 11/29/12 10:42 AM Page 85

CrossLab Vials and Closures

19 mm Septa for 5 mL and 10 mL Snap Caps


Agilent
CrossLab
Septa Type Unit Part No.
Red rubber 100/pk 8010-0430
CrossLab vial, snap top shell vial, 1 mL, 8 mm,
clear, with polypropylene cap, 8010-0574
1 mL (8 mm) Snap Top Shell Vial Convenience Packs, 100/pk
Agilent
CrossLab
Vial Type Cap Part No.
Clear Polypropylene 8010-0574
Amber Polypropylene 8010-0575

CrossLab vial, snap top shell vial, 1 mL, 8 mm,


amber, with polypropylene cap, 8010-0575
To obtain an optimal fit and seal of any vial and closure, we strongly recommend buying an entire CrossLab vial assembly
(including a vial, cap, and septum, as well as a vial insert if needed). Please avoid mixing and matching any CrossLab vials
with any other brand of closures, or any CrossLab closures with any other brand of vials.

www.agilent.com/chem/CrossLabHPLC 85
06_Vials_Layout 1 11/29/12 10:42 AM Page 86

CrossLab Vials and Closures

CrossLab Polypropylene Vials


Wide opening 12 x 32 mm vials are manufactured from virgin polypropylene, meeting the
requirements of 21 CFR 177.1520. Polypropylene vials are translucent and can be used with crimp or
snap caps.

Polypropylene Vials
CrossLab polypropylene vial, crimp/snap top,
Agilent
8010-0158
Recommended Max Fill CrossLab
Description Fill Volume Volume Unit Part No.
Polypropylene, crimp/snap top 250 µL 440 µL 100/pk 8010-0158
Polypropylene, crimp/snap top 250 µL 440 µL 1000/cs 8010-0193
Polypropylene, crimp/snap top 0.7 mL 1 mL 100/pk 8010-0159
Polypropylene, screw top 250 µL 440 µL 100/pk 8010-0161
Polypropylene, screw top 250 µL 440 µL 1000/cs 8010-0194
Polypropylene with glass insert, 250 µL 350 µL 100/pk 8010-0160
crimp/snap top
Polypropylene crimp/snap top vial with glass
insert, 8010-0160 Polypropylene with glass insert, screw top 250 µL 350 µL 100/pk 8010-0162

To obtain an optimal fit and seal of any vial and closure, we strongly recommend buying an entire CrossLab vial assembly
(including a vial, cap, and septum, as well as a vial insert if needed). Please avoid mixing and matching any CrossLab vials
with any other brand of closures, or any CrossLab closures with any other brand of vials.

86 Agilent CrossLab HPLC & Electrochemistry Supplies Selection Guide


06_Vials_Layout 1 11/29/12 10:42 AM Page 87

CrossLab Vials and Closures

CrossLab Micro-V Vials


• Wide opening, 1.5 mL vials with low residual volume
• Made from first hydrolytic glass Type 1
• Standard 12 x 32 mm dimension
• Compatible with 11 mm crimp closures
Clear, crimp top Micro-V vial, 8010-0004

Micro-V Vials
Description Unit Screw Top Crimp Top Snap Top
Clear, screw top 100/pk 8010-0018 8010-0004 8010-0027
Amber 100/pk 8010-0019 8010-0005 8010-0028
TIPS & TOOLS
For economical and effective
microsampling, choose the
To obtain an optimal fit and seal of any vial and closure, we strongly recommend buying an entire CrossLab vial assembly polypropylene vial with molded glass
(including a vial, cap, and septum, as well as a vial insert if needed). Please avoid mixing and matching any CrossLab vials
flanged insert. Its polypropylene
with any other brand of closures, or any CrossLab closures with any other brand of vials.
body has a glass flanged insert
molded to the inside, so the sample
comes in contact only with the high
quality glass insert and the septum.
For additional help in selecting vials, caps, and septa,
go to www.agilent.com/chem/SelectVials

www.agilent.com/chem/CrossLabHPLC 87
06_Vials_Layout 1 11/29/12 10:42 AM Page 88

CrossLab Vials and Closures

CrossLab Microvolume Inserts


To meet your microsampling needs, Agilent offers a variety of microvolume inserts with capacities
and designs that can transform your vials from full-capacity to limited volume with one simple step.

Microvolume inserts Microvolume Inserts for 8 mm Screw Top Vials


Agilent
Recommended Max CrossLab
Description Fill Volume Fill Volume Unit Part No.
Glass conical insert with polymer feet 150 µL 200 µL 100/pk 8010-0124
Glass pulled-point insert 150 µL 200 µL 100/pk 8010-0125
Flat bottom insert 200 µL 220 µL 100/pk 8010-0126

Microvolume Inserts for 11 mm Crimp Top or 9 mm Screw Top Vials


Agilent
Recommended Max CrossLab
Description Fill Volume Fill Volume Unit Part No.
250 µL conical insert with polymer feet,
8010-0131 Conical insert with polymer feet 250 µL 330 µL 100/pk 8010-0131
Pulled-point insert 250 µL 350 µL 100/pk 8010-0132
Flat bottom insert 400 µL 440 µL 500/pk 8010-0136

Microvolume Inserts for 4 mL (13 mm) Screw Top Vials


Agilent
Recommended Max CrossLab
Description Fill Volume Fill Volume Unit Part No.
250 µL pulled-point glass insert, 8010-0132 Pulled-point insert with flange 250 µL 350 µL 100/pk 8010-0558

To obtain an optimal fit and seal of any vial and closure, we strongly recommend buying an entire CrossLab vial assembly
(including a vial, cap, and septum, as well as a vial insert if needed). Please avoid mixing and matching any CrossLab vials
with any other brand of closures, or any CrossLab closures with any other brand of vials.

400 µL flat bottom glass insert, 8010-0136


For additional help in selecting vials, caps, and septa,
go to www.agilent.com/chem/SelectVials

88 Agilent CrossLab HPLC & Electrochemistry Supplies Selection Guide


06_Vials_Layout 1 11/29/12 10:42 AM Page 89

CrossLab Vials and Closures

CrossLab Well Plates and Sealing Mats


Agilent CrossLab offers a range of polypropylene 96-well or 384-well plates with a variety of sealing options for collection of samples, storage,
and use in autosamplers.

Well Plates
Plate Agilent
Well Volume Height Well Depth CrossLab
Description (mL) Material (mm) (mm) Well Shape Bottom Shape Unit Part No.
96-well plate 0.2 Polypropylene 20.9 20.9 Round Conical 50/pk 8010-0532
96-well plate 0.5 Polypropylene 26.5 21.6 Round Round 56/pk 8010-0533
96-well plate 1.0 Polypropylene 39.1 37.1 Round Round 32/pk 8010-0534
96-well plate 2.0 Polypropylene 44 41.85 Round Round 32/pk 8010-0536
384-well plate 0.1 Polypropylene 14.4 11.7 Square Round 120/pk 8010-0538
384-well plate 0.25 Polypropylene 22 19.5 Square Round 60/pk 8010-0539

Sealing Mats and Accessories


Agilent
CrossLab
Description Unit Part No.
Sealing mat for 0.2 mL 96-well plates, Thermoplastic Elastomers (TPE) 5/pk 8010-0577
Sealing mat for 0.5 mL and 1.0 mL 96-well plates, Thermoplastic Elastomers (TPE) 50/pk 8010-0535
Sealing mat for 2 mL 96-well plate, Ethylene Vinyl Acetate (EVA) 50/pk 8010-0537
Sealing tape for 384-well plate, polyethylene 100/pk 8010-0540
Sealing foil, self adhesive, high transparency, for all plates, Polyethylene terepthalate (PET) 100/pk 8010-0541
Sealing foil, self adhesive, for all plates, Polypropylene 100/pk 8010-0578

96-well plate
with removable sealing mat,
8010-0534 Sealing mat for 0.2 mL 96-well Sealing mat for 2 mL 96-well plate,
plates, Thermoplastic Elastomers Ethylene Vinyl Acetate (EVA),
(TPE), 8010-0577 8010-0537

www.agilent.com/chem/CrossLabHPLC 89
06_Vials_Layout 1 11/29/12 10:42 AM Page 90

CrossLab Vials and Closures

CrossLab Vials Cross Reference List


The cross references to the original equipment manufacturer (OEM) part numbers listed here serve as a recommendation that the CrossLab
products are viable alternatives to OEM products. CrossLab products are compatibile with the corresponding OEM instruments, although in some
cases, the CrossLab products may have slightly different designs as compared to the OEM counterparts.

CrossLab Vials CrossLab Vials CrossLab Vials CrossLab Vials


for Bruker/Varian for Bruker/Varian for Bruker/Varian for Bruker/Varian
Similar to Agilent Similar to Agilent Similar to Agilent Similar to Agilent
Bruker/Varian CrossLab Bruker/Varian CrossLab Bruker/Varian CrossLab Bruker/Varian CrossLab
Part No. Part No. Part No. Part No. Part No. Part No. Part No. Part No.
392611525 8010-0195 392611645 8010-0059 392620204 8010-0044 CP912446 8010-0418
392611530 8010-0414 392611645 8010-0069 392620302 8010-0139 CP913077
392611549 8010-0198 392611646 8010-0015 392620304 CP959464 8010-0420
392611550 8010-0199 392611653 392620306 8010-0140 CP959485 8010-0155
392611593 8010-0125 392611654 8010-0017 392620401 8010-0417 39260500 8010-0014
190010204 8010-0131 392611659 8010-0084 392620403 CPLC40111B
392611594 392611659 8010-0086 392620500 8010-0175 CPLC40111R
392620538 392611659 8010-0088 CPLC40111B CPLCL07CPVA 8010-0172
392611596 8010-0132 392611667 8010-0159 CPLC40111R CPLCL11ACBST144 8010-0183
392611636 392611675 8010-0034 190010209 8010-0092 MLA110040M 8010-0152
392611607 8010-0143 392612021 392620510 392611860 8010-0165
392611607 8010-0413 MLA202100 190010209 8010-0093 392612017
392611613 8010-0142 392611857 8010-0151 392620510 MLA2000051ML
392611613 8010-0412 392610003 8010-0116 392620514 8010-0008 MLA21000 8010-0030
392611631 8010-0050 392611858 392620517 8010-0170 R000548SCY 8010-0160
392611632 8010-0051 ROK7382420 392620526 8010-0032
390886500 8010-0002 392611859 8010-0121 392620528 8010-0036
392611634 392611871 8010-0108 1600069800 8010-0070
392611639 8010-0011 392611970 8010-0416 390614901 8010-0072
392620550 392611974 6900016900
CP10271 392611975 R005486RT1
392611640 8010-0013 392611980 CP10204 8010-0029
392611641 8010-0056 392611981 CP10205 8010-0033
392611641 8010-0061 392611982 CP10277 8010-0020
392611645 8010-0064 392620104 8010-0040 CP741315 8010-0038
392611641 8010-0066 392620202 8010-0042 CP913323
(Continued) (Continued) (Continued)

90 Agilent CrossLab HPLC & Electrochemistry Supplies Selection Guide


06_Vials_Layout 1 11/29/12 10:42 AM Page 91

CrossLab Vials and Closures

CrossLab Vials CrossLab Vials CrossLab Vials CrossLab Vials


for PerkinElmer for Shimadzu for Thermo Scientific for Thermo Scientific
Similar to Agilent Similar to Agilent Similar to Similar to
PerkinElmer CrossLab Shimadzu CrossLab Thermo Agilent Thermo Agilent
Part No. Part No. Part No. Part No. Scientific CrossLab Scientific CrossLab
B0104239 8010-0143 038-00165-06 8010-0011 Part No. Part No. Part No. Part No.
B0104241 8010-0144 220-90384-00 8010-0055 60180-507 8010-0008 60180-526 8010-0046
B4000022 8010-0122 220-90393-00 8010-0020 10-800-247 8010-0038 60180-560 8010-0012
B4000025 8010-0121 220-90394-00 8010-0096 14-824-365 8010-0042 60180-561 8010-0016
N6356478 8010-0030 220-91521-14 8010-0095 60180-502 8010-0001 C4000-2W
N6356479 8010-0038 220-94562-00 8010-0412 C4011-1W 2SVW(A)
N9300500 8010-0195 220-94563-00 8010-0413 2-CV 11 09 0520
N9300700 8010-0198 220-94796-01 8010-0042 11 09 0476 60180-562 8010-0066
N9301385 8010-0002 220-94796-02 8010-0119 60180-504 8010-0030 60180-597 8010-0195
N9302680 8010-0003 220-94796-07 8010-0038 10-800-246 60180-599 8010-0198
N9302684 8010-0047 221-34271-92 8010-0054 60180-505 8010-0032 60180-713 8010-0112
N9302685 8010-0048 221-34271-92 8010-0056 14-824-360 C4013-98Y 8010-0166
N9302686 8010-0046 221-34271-92 8010-0072 60180-506 8010-0034
N9303416 8010-0106 228-21290-91 8010-0098 60180-507 8010-0008
N9303416 8010-0113 228-45450-91 8010-0198
CrossLab Vials
60180-508 8010-0010
for Waters
N9303417 8010-0105 228-45452-91 8010-0199 60180-509 8010-0014
Similar to Agilent
N9303417 8010-0112 C4000-1W
Waters CrossLab
N9303418 8010-0024 2SVW Part No. Part No.
N9303419 8010-0104 11 09 0519 186000842 8010-0557
N9303419 8010-0111 60180-510 8010-0020 186001420 8010-0563
N9303441 8010-0055 C4015-1 186001421 8010-0565
N9303442 8010-0073 4-SV 186001422 8010-0564
N9303992 8010-0413 13 09 0222 186000307C 8010-0542
N9306015 8010-0051 60180-511 8010-0116 186000838C 8010-0553
N9306052 8010-0054 60180-513 8010-0117 186000839C 8010-0555
N9306075 8010-0042 60180-514 8010-0055 186000847C 8010-0543
N9306077 8010-0119 60180-514 8010-0060 186001133C 8010-0554
N9306079 8010-0034 60180-514 8010-0065 186001134C 8010-0556
N9306201 8010-0015 60180-514 8010-0070 WAT025053C 8010-0575
N9306202 8010-0086 60180-515 8010-0061 WAT025054C 8010-0574
N9306207 8010-0023 60180-516 8010-0086
N9306208 8010-0025 60180-521 8010-0122
N9306220 8010-0017 60180-522
N9306228 8010-0050
(Continued)
N9306229 8010-0049
N9306240 8010-0152
N9306247 8010-0020

www.agilent.com/chem/CrossLabHPLC 91
07_Electrodes_Layout 1 11/29/12 10:43 AM Page 92

CrossLab Supplies for pH Meters

CrossLab pH Electrodes
The electrodes shown here use universal connections, so you can use them interchangeably on a wide range of popular benchtop meters.

8010-0985 8010-0986 8010-0972 8010-0975 8010-0973


ü Combination electrode ü Combination electrode ü Combination electrode ü Combination electrode ü Electrode with glass body
with glass body with PC body with PC body with ABS body ü Non-refillable
ü Refillable ü Refillable ü Non-refillable ü Non-refillable ü BNC connector
ü BNC connector ü BNC connector ü BNC connector ü BNC connector ü Glass bulb measuring tip
ü Glass bulb measuring tip ü Flat measuring tip ü Glass bulb measuring tip ü Spear-tipped measuring tip

92 Agilent CrossLab HPLC & Electrochemistry Supplies Selection Guide


07_Electrodes_Layout 1 11/29/12 10:43 AM Page 93

CrossLab Supplies for pH Meters

Agilent CrossLab pH Electrodes – Applications and Compatibility Table


Original
Equipment Similar to Agilent
Manufacturer OEM CrossLab Electrode CrossLab
(OEM) OEM pH Meter Application Electrode Description Part No.
Mettler Toledo SevenMulti Routine measurement of most InLab Basics Refillable pH combination 8010-0985
SevenCompact samples, field measurement BNC electrode with glass body
and student/education use. InLab Routine
FiveEasy Recommended for biological samples,
FiveEasy Plus such as buffers, and proteins enzymes
Measurements that may damage InLab Mono Non-refillable pH electrode 8010-0973
the lifetime of the electrode, with glass body
such as corrosive or organic samples
Fruit, cheese, meat and other InLab Solids Non-refillable pH 8010-0975
solid measurements combination electrode
with ABS body
Routine measurement of most samples LE407 Non-refillable pH 8010-0972
in harsher environments, such as field InLab Easy combination electrode
or plant use with PC body
Flat surface samples such as skin, InLab Surface Refillable pH combination 8010-0986
paper, leather, etc. electrode with PC body
Thermo Orion Star A111 Routine measurement of most 8102BNUWP Refillable pH combination 8010-0985
Scientific Orion Star A211 samples, field measurement electrode with glass body
and student/education use.
Orion VERSA Recommended for biological samples,
STAR 10 such as buffers, and proteins enzymes
Orion 3-Star Fruit, cheese, meat and other 8163BNWP Non-refillable pH 8010-0975
Orion 4-Star solid measurements combination electrode
with ABS body
Routine measurement of most samples 9156APWP Non-refillable pH 8010-0972
in harsher environments, such as field combination electrode
or plant use with PC body
HANNA HI 2221 Routine measurement of most Refillable pH combination 8010-0985
Instruments samples, field measurement and electrode with glass body
student/education use. Recommended
for biological samples, such as buffers,
and proteins enzymes
Fruit, cheese, meat and other Non-refillable pH 8010-0975
solid measurements combination electrode
with ABS body
Routine measurement of most samples Non-refillable pH 8010-0972
in harsher environments, such as field combination electrode
or plant use with PC body
Flat surface samples such as skin, Refillable pH combination 8010-0986
paper, leather, etc. electrode with PC body
To learn more about CrossLab electrodes and a full range of CrossLab pH buffers, visit www.agilent.com/chem/CrossLabElectrochemistry.

Key Description
PC Polycarbonate
ABS Acrylonitrile Butadiene Styrene

www.agilent.com/chem/CrossLabElectrochemistry 93
07_Electrodes_Layout 1 11/29/12 10:43 AM Page 94

CrossLab Supplies for pH Meters

CrossLab pH Electrode Specifications

Model 8010-0985 8010-0986 8010-0972 8010-0975 8010-0973


Measurement Range (0-14) pH (0-14) pH (0-14) pH (0-14) pH (0-14) pH
PTS ≥ 97% ≥ 97% ≥ 97% ≥ 97% ≥ 98.5%
Response time 30s 60s 30s 60s 60s
Electrode impedence ≤ 300 MW ≤ 500 MW ≤ 300 MW ≤ 500 MW ≤ 250 MW
Reference type Ag/AgCl Ag/AgCl Ag/AgCl Ag/AgCl –
Liquid junction material Ceramic Fiber Porous polymer Fiber –

CrossLab pH Electrode Recommended Uses*

Industry Sample 8010-0985 8010-0986 8010-0972 8010-0975 8010-0973


Drinks Milk 3 3 3
and Dairy Soy Sauce 3 3 3
products
Beer 3 3 3
Soft drinks 3 3 3
(iced black tea)
Food and Compound 3
Agricultural fertilizer
products Jam 3
Meat 3
Vegetables 3 3 3
Waste 3
Chemical Electroplate liquid 3 3
reagents and
electrolytes
Coatings, Suspended solid 3
dyes, (soil)
and latex
Daily water Tap water 3 3
Drinking water 3
Refillable pH combination electrode (barreled water) (Static)
with glass body, 8010-0985
Distilled water 3
(Sealed)
Drug or Protein 3 3
biological sample/protein
samples powder
Surface Droplet size 3
measurement of the sample
Textiles 3
Cosmetics Shampoo 3 3
and viscous Cosmetics paste 3 3
samples
*Laboratory test; for reference only.

94 Agilent CrossLab HPLC & Electrochemistry Supplies Selection Guide


07_Electrodes_Layout 1 11/29/12 10:43 AM Page 95

CrossLab Supplies for pH Meters

CrossLab pH Electrodes*
Agilent
CrossLab
Description Part No.
Refillable pH combination electrode with glass body, and 30 mL pH reference solution 8010-0985
Refillable pH combination electrode with Polycarbonate (PC) body, and 30 mL pH 8010-0986
reference solution
Non-refillable pH combination electrode with Polycarbonate (PC) body 8010-0972
Non-refillable pH combination electrode with Acrylonitrile Butadiene Styrene 8010-0975
(ABS) body
Non-refillable pH electrode with glass body 8010-0973
*All CrossLab pH electrodes are shipped with a certificate of conformance and the certificate is also available online
in the literature library, www.agilent.com/chem/library.

CrossLab pH Buffer and Reference Solutions*


Agilent
CrossLab
Description Amount Part No.
pH buffer solutions, 4.01, 7.00, 10.01, NIST traceable 3 x 250 mL 8010-0976
pH buffer, 4.01 3 x 250 mL 8010-0978
pH buffer, 10.01 3 x 250 mL 8010-0979
pH buffer, 7.00 3 x 250 mL 8010-0980
Reference solution, pH 3 x 30 mL 8010-0984
*All CrossLab pH buffer and reference solutions are shipped with a certificate of analysis and are also available
online in the literature library, www.agilent.com/chem/library.

www.agilent.com/chem/CrossLabElectrochemistry 95
07_Electrodes_Layout 1 11/29/12 10:43 AM Page 96

CrossLab Supplies for pH Meters

CrossLab Supplies Online Interactive Selection Tool

With the CrossLab Selection Tool, it is quick and simple to identify the specific supplies you need.
Answer just a few questions, and you will find the HPLC supplies for your particular applications.
The tool is available in English, Chinese, and Japanese.

Learn more at
www.agilent.com/chem/SelectCrossLab

96 Agilent CrossLab HPLC & Electrochemistry Supplies Selection Guide


00_Cover_Layout 1 11/29/12 11:12 AM Page 2

Agilent CrossLab Selection Guide


for HPLC & Electrochemistry Systems
The Agilent LC Columns Family:
Choice, control and assured excellent results
Table of Contents Agilent designs and manufactures columns to suit most
techniques for small molecule, biomolecule and synthetic
polymer analysis, allowing you to scale methods from
1 CrossLab Product Introductions conventional 5 µm… to “Fast LC” sub-2 µm… to prep.
You have access to Agilent’s extensive applications
library for faster method development – plus worldwide
27 CrossLab Supplies for Waters HPLC Systems technical support, speedy problem resolution, our global
infrastructure, and delivery network.
Agilent’s meticulous production oversight ensures
42 CrossLab Supplies for Shimadzu HPLC Systems column consistency and performance. With more than
40 years of experience in producing polymers and silica
chemistries, our team is committed to continuously
developing new column advances that make you
49 CrossLab Supplies for Dionex HPLC Systems* most productive.
Learn more at
www.agilent.com/chem/lccolumns
64 CrossLab Supplies for CTC Analytics HPLC Autosamplers

65 CrossLab Vials and Closures

Simplify your workflow


89 CrossLab Well Plates and Sealing Mats
with Captiva Filtration
Family of Products
92 CrossLab Supplies for pH Meters
Maximize the benefits of Captiva
with these additional products
*Dionex is now a part of Thermo Scientific

Agilent Bond Elut SPE, Bond Elut QuEChERS


and Captiva Filtration Sample Prep family of products
offer the widest range of solutions for every level
of sample cleanliness to help you increase throughput
and increase the quality of your data.
Learn more at
www.agilent.com/chem/sampleprep
00_Cover_Layout 1 11/29/12 11:12 AM Page 1

CrossLab
Agilent
Supplies Selection Guide
for HPLC and
Electrochemistry Systems

Agilent CrossLab Selection Guide for HPLC & Electrochemistry Systems


2013 EDITION

For more information

Learn more:
www.agilent.com/chem/CrossLabHPLC
www.agilent.com/chem/CrossLabElectrochemistry

Buy online:
www.agilent.com/chem/store

U.S. and Canada


1-800-227-9770
[email protected]

Europe
[email protected]

Asia Pacific
[email protected]

India
[email protected] Put Agilent quality supplies
to work across your lab

Agilent CrossLab HPLC works with WATERS SHIMADZU THERMO SCIENTIFIC AND MORE

This information is subject to change without notice.


© Agilent Technologies, Inc. 2012
Printed in USA November 29, 2012
5991-1484EN

You might also like