TECHNICAL PROFILE

2 SMALL, MEDIUM AND LARGE POWER TRANSFORMERS WHO WE ARE

SGB-SMIT AT A GLANCE
Combined, more than More than In more than

450 3,500 80
YEARS OF EXPERIENCE
Basis for know-how and
EMPLOYEES
take care of
COUNTRIES
satisfied
for know-why your project customers

READY FOR YOUR MARKET PRODUCTS


The SGB-SMIT Group manufactures transformers • large power transformers
for applications worldwide. Sales and service • medium power transformers
centers on all continents ensure optimum • large liquid-cooled distribution transformers
processes. • liquid-cooled distribution transformers
• cast resin transformers
Our products meet the requirements in accordance • shunt reactors
with the applicable national standards. • series reactors
• phase shifters
• Lahmeyer-Compactstationen®

Transformers from 50 kVA up to incl. 1,200 MVA in the


voltage range up to 765 kV.

QUALITY MANAGEMENT TECHNOLOGIES


The SGB-SMIT Group is certified in accordance with: Technologies for conventional and
• DIN ISO 9001 renewable energy.
• DIN ISO 14001
• DIN ISO 50001
• OHSAS 18001

Status: December 2019


SGB-SMIT GROUP SMALL, MEDIUM AND LARGE POWER TRANSFORMERS 3

SGB SMIT POWER MATLA


A MEMBER OF THE SGB-SMIT GROUP

SGB-SMIT POWER MATLA has over 70 years experience in successful design, manufacturing, testing, installation and commissioning of a
full range of power and distribution transformers which include large power transformers of voltages up to 800MVA.

SGB-SMIT POWER MATLA ”CUSTOM DESIGNED“


SGB-SMIT POWER MATLA (Pty) Ltd is owned by SGB-SMIT Every SGB-SMIT POWER MATLA unit is custom-made from
(GmbH) and Power Matla. standardised design elements and using uniform manufacturing
operations. This flexible, but well co-ordinated approach
SGB-SMIT, is the largest independent and pure-play ensures the highest quality of design and construction for
transformer manufacturer in the world, with headquarters in all our transformers and makes the best possible use of the
Regensburg, Germany. They are represented on 5 continents valuable knowledge and experience gained over the years and
in 8 countries with plants in Germany, the Netherlands, USA, best practices developed in our factory.
Romania, Malaysia, India, China and the Czech Republic. With
transformer expertise since 1913 they produce transformers The Large Power Transformer factory in Pretoria is a well-
ranging from 50 kVA up to 1,200 MVA. equipped factory and is amongst the biggest and most
sophisticated transformer manufacturing plants within the
Power Matla (Pty) Ltd is a locally owned black empowered Southern Hemisphere and one of two large transformer
company with investments in various portfolios within the manufacturers within sub-Saharan Africa.
renewable energy, ICT, mining and power utilities markets
providing good shareholder value and solid returns. The Distribution Transformers factory in Cape Town has
been manufacturing distribution transformers and miniature
The company consists of Large Power Transformers substations for more than 60 years.
manufacturing plant in Pretoria and Distribution Transformers
plant in Cape Town and supplies a full range of transformers,
from generator step-up to transmission and distribution
transformers. The range includes three-phase and single-
phase units, auto-transformers, arc-furnace, locomotive and
traction transformers, miniature sub-stations, NECRT’s as well
as shunt reactors.
4 SMALL, MEDIUM AND LARGE POWER TRANSFORMERS CUSTOMERS

SMALL, MEDIUM AND LARGE POWER


TRANSFORMERS ALL OVER THE WORLD
1 Shipping
2 Oil & Gas
3 Solar Power Stations
11
4 Power Plants
6
5 Onshore
9
1 6 Offshore
10
7 Power Distribution
4
8 Railway
7
2 4 9 Industry
3
5
10 High Buildings / Data Center
8
11 Hydro Power

EXPERIENCE AND DESIGN DESIGNS


CAPABILITY The transformers manufactured by SGB-SMIT POWER
MATLA range from standard designs in accordance with IEC
requirements to complex designs specific for a customer’s
SGB-SMIT POWER MATLA has many years of experience in the individual requirements in all applications and industries across
design, manufacturing, installation and commissioning of small, the African continent and overseas.
medium and large power transformers for various applications.
The software available to our designers is a state of the art
Our design experience ranges from small power transformers integrated design system. This includes winding design and
(SPT – < 60MVA, < 132kV) up to large power transformers (LPT optimisation; graphical electromagnetic field line plots by means
– 800MVA, 500kV) including Generation Step-up Units (GSU’s). of 3D Finite Element Method modelling; temperature analysis;
In addition, all aspects of auxiliary control circuit application and short circuit stress calculations to full 3D CAD modelling of the
layout designs are also provided. transformer and its components. This allows our designers to
customise each power transformer to specific customer
requirements.
DESIGN SMALL, MEDIUM AND LARGE POWER TRANSFORMERS 5

QUALITY, HEALTH, SAFETY & DESIGN REVIEWS


ENVIRONMENT
The power transformer plant located in Pretoria (Gauteng) is a
world class manufacturing facility and boasts a fully certified ISO
9001 quality management system, ISO 14000 environmental
management system as well as the OHSAS 18000 health and
safety management system.

At every stage during manufacturing, the materials and


processes are inspected by suitably qualified and experienced
inspectors to ensure all required standards and manufacturing
practices are adhered to. Six-sigma systems are built into every
manufacturing process in the factory to enhance the quality and
documentation of our products.

Customer drawings are prepared for tender designs and finalised


on order placement. All electrical and mechanical designs
undergo an internal design review process. External design
reviews by customers are also allowed for in the design process.
If a detailed customer specification is not available,

SGB-SMIT POWER MATLA can offer a cost effective design based


on the requirements of IEC 60076 product standards.

SGB-SMIT POWER MATLA can also provide template technical


schedules based on the IEC requirements, should these not be
available from the customer.
6 SMALL, MEDIUM AND LARGE POWER TRANSFORMERS SUPPLY CHAIN

TRANSFORMERS MADE BY SGB-SMIT


POWER MATLA - STANDARD FEATURES

SUPPLY CHAIN CORE DESIGN


SGB-SMIT POWER MATLA prides itself in our ability to Core design principles are based on achieving the smallest
leverage our global network. We also manufacture most of the active part possible whilst achieving low noise level, low no-load
transformer structural components in-house. Raw materials and losses and ensuring high short circuit withstand capability of the
components not manufactured in-house are sourced from world overall core structure. The basic core design is either a three-
class suppliers. Procurement of material and components is done limb or a five-limb type core. The core is composed of a circular
from a list of pre-qualified suppliers locally and internationally cross-section without any bolts through the core. The joints are
who are certified to conform with the highest standards in terms mitred and step-lap stacked.
of Quality (ISO9001), Health and Safety (OHSAS 18000) as well
as Environmental (ISO 14000) respectively. Selection of core steel material for a particular core ranges
from conventional grain orientated electrical steel (GOES);
Before a supplier is approved, their capability is assessed, by to domain refined grain orientated electrical steel based on
taking into consideration their technical ability; quality control customer specifications for no-load losses and noise levels.
system; safety, health & environmental controls; financial viability
as well as other commercial factors. Supply level agreements Transport restrictions on weight and dimensions may influence
are put in place with key suppliers to ensure availability of stock the most appropriate core geometry for the transformer that
and continuity of supply. A number of enterprise development is economical on losses; flux density; overall core weight and
initiatives are considered for development of small independent sound level.
business units.

SGB-SMIT POWER MATLA applies strict control of incoming


raw material from pre-qualified suppliers. All incoming goods
are quality-controlled and checked before they are released
into the sub-assembly manufacturing lines. Where certification
is required, the raw material is sent to our on-site SANAS
accredited laboratory for material analysis, verification and
certification. Any non-conforming product is rejected and
returned to the supplier for rectification or replacement.
WINDING DESIGN SMALL, MEDIUM AND LARGE POWER TRANSFORMERS 7

WINDING DESIGN WINDING MANUFACTURE


The transformer windings must have the ability to withstand high Winding technologies are layer, helical, continuous disk and
mechanical and electrical stresses resulting from short circuit interleaved disk depending on the operating conditions as
conditions, lightning and switching surges as well as normal determined by the rated apparent power; rated voltage;
overload requirements during peak hours in daily operation network fault level as well as the climatic conditions of the site
throughout the lifetime of the transformer. of operation and specified temperature rise limits. Disk windings
are suitable for higher voltages while layer and helical windings
Windings manufactured by SGB-SMIT POWER MATLA are made are suitable for lower voltages.
of annealed copper and guarantee high mechanical; electrical;
and thermal stability under abnormal conditions. This ensures The conductor used on windings is oxygen free copper. The
the safe operation of the transformer over it’s lifetime. shape of the conductors is rectangular with small edge-radii. The
conductor is often divided into two or more parallel strands to
reduce the eddy current losses within the winding. transformer
with regard to the electrical and mechanical requirements.

Each strand is insulated either by thermally upgraded paper


covering, or by an enamel coating, or both. Two separately
insulated and parallel strands may sometimes have a common
paper covering. Conductor types can be strip conductor or CTC
(Continuously Transposed Conductor).

Manufacturing of windings is carried out by suitably qualified and


experienced winders on vertical or horizontal winding machines.
Winding machines are precisely controlled to achieve constant
contact pressure and winding tension.
8 SMALL, MEDIUM AND LARGE POWER TRANSFORMERS W INDING MANUFAC T URE

INSULATION MATERIAL INSULATION OIL


Material for the insulation structure and barrier boards is The mineral oil inside the transformer tank acts as an insulation
manufactured from high quality compressed transformer board, medium as well as a coolant for the windings inside the
compacted laminated wood and/or fibre sheets depending on the transformer. The mineral oil used in our transformers complies
application within thetransformer with regard to the electrical with international standards. Only virgin oil is used (free of
and mechanical requirements. contaminates) and no recycled oil is used to fill the transformers.

Elevated temperatures (hot-spots) in transformers are


detrimental to paper insulation’s longevity due to the
decomposition of the cellulose bonding inside the paper.
This results in the degradation of the insulation between
strands which may lead to premature insulation failure of the
transformer.

For paper insulated conductor used on windings, SGB-SMIT


POWER MATLA has standardised on thermally upgraded paper
for all windings types. This ensures an additional 10Kelvin hot
spot temperature margin resulting in an extended life of the
transformer.
TANK MANUFAC T URE SMALL, MEDIUM AND LARGE POWER TRANSFORMERS 9

TANK DESIGN TANK MANUFACTURE


The transformer tank accommodates the core and windings The transformer tank is usually of the rigid type with removable
(active part) as well as insulating oil. It serves as a support radiators connected by shut-off valves. The tank shape and size
structure for accessories and control equipment as well as is designed to optimise the quantity of material used taking into
acting as physical protection for the active part. Due to its vital consideration the electrical clearance requirements, structural
role the tank design must be robust and very reliable implying strength and required oil volume.
the use of high quality material.
The base is flat with a minimum thickness of 20mm and is
determined by the lifting capacity required for the core and
winding masses.

Mild steel plates are the main building material used in our
tank, cover and conservator as well as all the pipes and
fittings. However, where there is a serious concern with high
temperatures caused by eddy losses around high current
carrying bushings in which case stainless steel is used instead.

Double welding is used where oil tightness is required. Rubber


or cork rubber compound is used for the gaskets on flanged
connected pipe joints/transport and inspection cover openings
and all other valves and fittings.
10 SMALL, MEDIUM AND LARGE POWER TRANSFORMERS PAIN T ING & S URFACE T RE AT MEN T

PAINTING AND SURFACE MAIN TERMINALS


TREATMENT Customers have a choice of bushings from standard solid
porcelain oil impregnated (OIP) type bushings to resin
impregnated (RIP) bushings for various applications such as
SGB-SMIT POWER MATLA has a range of proven surface
Oil-to-Air, Oil-to-Oil, Oil-to-SF6, Air-to-Air and Air-to-SF6.
treatments depending on the transformer site climatic
Our bushings are always sourced from world class suppliers
conditions and application environment. All paint and coatings
of bushings, who comply with international standards and are
are done in accordance with a documented in-house painting
generally positioned on the cover.
system complying with strict safety, health, environmental and
quality requirements.
For voltages above 52 kV, condenser type bushings which
facilitate the electric stress control via the insertion of floating
All new transformers, irrespective of whether they are
aluminium equaliser screens which are located in the condenser
operating in non-corrosive or corrosive environments, are
core are used. Enclosures can be provided on the primary and/or
coated in accordance with SGB-SMIT POWER MATLA‘s
on the secondary side and may be constructed for cable or bus
corrosive protection specification. External tank surfaces are
duct connection. Transformers may also be provided with plug-
painted with a two-component epoxy primer followed by a two-
in or cable box bushings.
component acrylic or polyurethane finishing coat.

Separate radiators are generally hot-dip galvanised. Moreover,


test standards include partial discharge measurements at a
max. basic interference level of approx. 10 - 20 pC, allowing
significant improvement on the value specified by the applicable
standards.

In addition to the standard corrosion protection painting


system, a zinc-metal spray coating can be applied on customer
request. Other customer specific painting system requirements
are also provided for. All external surfaces of the transformer
and accessories are colour coded in accordance with the
Natural Colour System (NCS codes) or RAL international colour
standards to a customer’s unique requirements.
ACCESSORIES SMALL, MEDIUM AND LARGE POWER TRANSFORMERS 11

ACCESSORIES DRYING AND VACUUM


Depending on the type and application of the transformer
TREATMENT
the accessories will usually include a combination of the
following items either as standard or optional as per customer
The moisture content in oil and solid insulation can have adverse
requirements:
effects on the life span of the transformer since it affects the
• Bushings (Oil or Resin Impregnated, Oil-to-Air, Oil-to-Oil; Oil-
dielectric breakdown strength of solid and liquid insulation. This
to-SF6)
affects the rate at which the cellulose ages and the propensity
• Oil conservator with level indicator
for bubble evolution during overloads.
• Rubber-bag with bag leak detector in the conservator to
prevent oil coming into direct contact with air
In order to counteract these negative effects of moisture
• Tap changers (oil type as well as vacuum)
adequate drying and vacuum treatment is performed using
• Filling and drain valves
proven technology such as Vapour Phase Drying and Low
• Oil sampling device
Frequency Heating (LFH). Before filling, the oil is always
• Earthing terminals
degassed and purified.
• Lifting lugs
• Jacking pads
• Radiator panels
• Silica-gel breather
TESTING
• Buchholz relay (GOR)
• Winding Temperature Indicators and Oil Temperature Every SGB-SMIT POWER MATLA transformer is individually
Indicators (Analogue or Digital). tested according to major international standards as well as, in
• Fibre optic probes for direct hot spot temperature accordance with any special tests required by the customer, and
measurements on active part. must pass all these tests before leaving the factory. The test
• Pressure relief devices and provision for pressure purging certificate forms part of the transformer operating manual.
systems.
• Provision for water cooled systems
• Impact recorders SFRA
• Separate core and core clamp earth test positions
SFRA (Swept Frequency Response Analysis) fingerprinting is
Other additional accessories can be fitted according to customer
also done before the transformer leaves the factory and redone
specifications.
on site.

Impact recorders are installed on the core as well as on the tank


of the transformer to verify adverse impacts or accelerations
in all three dimensions. Results of the SFRA test and impact
recorder data are made available to our customers.
12 SMALL, MEDIUM AND LARGE POWER TRANSFORMERS SMALL POWER TRANSFORMERS

STANDARD AND COMPLEX SMALL AND


MEDIUM POWER TRANSFORMERS

SMALL POWER (SPT’S) MEDIUM POWER (MPT’S)


SGB-SMIT POWER MATLA designs and manufactures small SGB-SMIT POWER MATLA designs and manufactures medium
power transformers (SPT) ranging from 20 MVA to 63 MVA power transformers (MPT) ranging up to 200 MVA 275 kV. Other
and up to 172 kV. The SPT range covers standard or complex power transformer sizes in the MPT range are rated above
applications from the typical substations to furnaces, tractions, 200 MVA up to 72 kV. The MPT range covers mostly customer
rectifiers and reactors. applications such as GSU and system power transformers.

We have the skills and resources to deal with specific customer We have the skills and resources to deal with customer needs,
needs in terms of engineering or assembly requirements, special however complex these may be in terms of engineering or
accessories as well as special materials or components. The assembly requirements; special accessories and special
following transformers are included in the SPT range: materials or components. The following transformers are
included in the MPT range:
• Double Wound or Auto-Connected
• Outdoor bushings or cable box applications • 3 phase with/without OLTC/OLTS/Link Board
• 3 phase with/without OLTC • 2 windings with/without OLTC/OLTS/Link board and with/
• 2 windings with/without OLTC and with/without stabilising without (not loaded) stabilising winding
winding. • ONAN/ONAF/OFAF/ODAF cooling
• ONAN/ONAF/OFAF/ODAF cooling • Standard/High impedances
• Standard/High impedance • Low sound pressure level
• Low sound pressure level
IN S TAL L AT ION & SERVICE SMALL, MEDIUM AND LARGE POWER TRANSFORMERS 13

LARGE POWER (LPT’S)


SGB-SMIT POWER MATLA designs and manufactures large The following transformers are included in the LPT range:
power transformers (LPT) with a three phase power rating
higher than 200 MVA or with voltage ratings higher than 275 • 3 phase with/without OLTC/OLTS/Link Board
kV. We supply three phase units up to 800 MVA and single • 2 windings with/without OLTC/OLTS/Link board and with/
phase units up to 500 MVA. LPT’s are mostly commonly used in without (not loaded) stabilising winding
customer applications such as GSU transformers, system power • ONAN/ONAF/OFAF/ODAF cooling
transformers and large transmission transformers. • Standard/High impedances
• Low sound pressure level
14 SMALL, MEDIUM AND LARGE POWER TRANSFORMERS T ECHNICAL DATA SHEE T S

TRANSFORMER RANGE DEFINITION


System
Voltage kV

LPT
> 275 kV

275 kV

MPT
> 200 MVA
172 < kV < 275kV (or BIL > 650kV)
LPT
172 kV
For SPT 1 - 5 max
> 200 MVA & > 72,5 kV
BIL 650 kV
SPT 1 - 2 SPT 3 - 5 MPT
< 40 MVA 40 < MVA < 63 > 63 < MVA & < 200
72.5 < kV < 171 > 72.5 - 171 kV 72.5 < kV < 172
Max BIL 650 kV Max BIL 650 kV

72.5kV

LDT LDT
< 40 MVA 40 < MVA < 63 MPT
< 72.5 kV < 72.5 kV > 63 MVA & < 72,5 kV

40MVA 63MVA 200MVA MVA

Transformer Front View


T ECHNICAL DATA SHEE T S SMALL, MEDIUM AND LARGE POWER TRANSFORMERS 15

TRANSFORMER RANGE DEFINITION


Transformer Top View

B
E

Transformer Side View


D
A
Note: For specific dimensions refer to tables on Pages 16 - 18
16 SMALL, MEDIUM AND LARGE POWER TRANSFORMERS T ECHNICAL DATA SHEE T S

SPT TECHNICAL DATA SHEET


MVA Nominal Voltage (kV Rating of Imped Vector Overall dimensions (m) Transformer Mass
rms) tertiary @Nom Group (Ton)
Prim Sec Ter (MVA) Tap(%) A B C D E F With Oil Without
Oil
20 132 88 22 5 9 YNa0d1 min 9.6 6.8 6.1 6.8 3.0 4.0 41 30
max 10.8 7.1 6.3 8.0 3.3 4.2 43 31

132 66 22 5 10 YNa0d1 min 9.2 6.7 5.9 6.4 2.9 3.8 40 27


max 10.2 7.0 6.1 7.4 3.2 4.0 42 28

132 44 22 5 11 YNa0d1 min 8.8 6.6 5.8 6.0 2.8 3.7 39 26


max 9.6 6.9 6.0 6.8 3.1 3.9 40 27

132 33 11 YNd1 min 8.5 6.5 5.6 5.7 2.7 3.5 37 26


max 9.2 6.8 5.8 6.4 3.0 3.7 39 28

132 22 11 YNd1 min 8.3 6.5 5.5 5.5 2.7 3.5 36 26


max 9.0 6.8 5.8 6.2 3.0 3.7 37 26

132 11 11 YNd1 min 8.2 6.5 5.4 5.4 2.7 3.4 35 25


max 8.7 6.8 5.7 5.9 3.0 3.6 36 27
22

132 6.6 10 YNd1 min 8.1 6.5 5.5 5.3 2.7 3.4 35 25
max 8.6 6.8 5.7 5.8 3.0 3.6 36 27
22

88 44 22 5 9 YNa0d1 min 8.6 6.7 5.7 6.2 2.9 4.0 38 28


max 9.4 7.0 5.9 7.0 3.2 4.2 40 30

88 44 10 YNd1 min 8.6 6.7 5.7 6.2 2.9 4.0 38 28


max 9.4 7.0 5.9 7.0 3.2 4.2 40 30

88 33 11 YNd1 min 7.9 6.5 5.5 5.5 2.7 3.8 34 26


max 8.6 6.8 5.7 6.2 3.0 4.0 36 27

88 22 11 YNd1 min 7.8 6.5 5.3 5.4 2.7 3.6 34 25


max 8.5 6.8 5.5 6.1 3.0 3.8 36 27

88 11 11 YHd1 min 7.7 6.5 5.1 5.3 2.7 3.4 33 25


max 8.3 6.8 5.3 5.9 3.0 3.6 36 26
22

88 6.6 11 YNd1 min 7.6 6.5 5.1 5.2 2.7 3.4 33 25


max 8.2 6.8 5.3 5.8 3.0 3.6 35 26
22

40 132 88 22 10 9 YNad1 min 10.6 6.8 6.1 7.8 3.0 4.0 50 39


max 11.2 7.1 6.4 8.4 3.3 4.3 53 42

132 66 22 10 10 YNa0d1 min 10.3 6.7 6.0 7.5 2.9 3.9 49 39


max 11.0 7.0 6.3 8.2 3.2 4.2 52 41

132 44 22 10 11 YNa0d1 min 10.0 6.7 5.9 7.2 2.9 3.8 48 37


max 10.7 7.0 6.2 7.9 3.2 4.1 51 39

132 33 11 YNd1 min 9.7 6.6 5.7 6.9 2.8 3.6 47 35


max 10.5 6.9 6.0 7.7 3.1 3.9 49 37

132 22 11 YNd1 min 9.3 6.5 5.7 6.5 2.7 3.6 47 35


max 10.2 6.8 6.0 7.4 3.0 3.9 49 37

132 11 11 YNd1 min 9.1 6.5 5.5 6.3 2.7 3.5 46 35


max 10.1 6.8 6.0 7.3 3.0 3.9 49 36
22

88 44 22 10 9 YNa0d1 min 10.2 6.8 5.7 7.8 3.0 4.0 52 38


max 10.6 7.1 6.0 8.2 3.3 4.3 55 40

88 44 10 YNd1 min 10.2 6.8 5.7 7.8 3.0 4.0 52 38


max 10.6 7.1 6.0 8.2 3.3 4.3 55 40

88 33 11 YNd1 min 8.9 6.6 5.4 6.5 2.8 3.7 46 36


max 9.7 6.9 5.6 7.3 3.1 3.9 49 38

88 22 11 YNd1 min 8.4 6.5 5.3 6.0 2.7 3.6 46 35


max 9.2 6.8 5.5 6.8 3.0 3.8 48 37

88 11 11 YNd1 min 8.1 6.5 5.1 5.7 2.7 3.4 45 35


max 9.1 6.8 5.3 6.7 3.0 3.6 48 37
22

88 6.6 11 YNd1 min 8.0 6.5 5.1 5.6 2.7 3.4 45 34


max 8.9 6.8 5.3 6.5 3.0 3.6 47 36
22

Notes:
Dimensions and masses in the above table are from typical designs completed in recent years and may vary from these values. Specific values might change based on specific
customer requirements.
Contact SGB-SMIT POWER MATLA to verify dimensions for specific applications.
Designs and sizes are not limited to the transformer sizes listed in the table above.
T ECHNICAL DATA SHEE T S SMALL, MEDIUM AND LARGE POWER TRANSFORMERS 17

MPT TECHNICAL DATA SHEET


MVA Nominal Voltage (kV Rating Imped Vector Overall dimensions (m) Transformer Mass
rms) of @Nom Group (Ton)
Prim Sec Ter tertiary Tap(%) A B C D E F With Without
(MVA) Oil Oil
40 220 66 22 10 Various YNa0d1 min 11.5 7.0 7.1 8.0 3.2 4.2 65 48
max 13.9 7.4 7.6 10.4 3.6 4.7 70 50
80 275 88 22 10 12.5 YNa0d1 min 12.3 7.0 7.8 8.3 3.2 4.2 88 63
max 13.5 7.4 8.3 9.5 3.6 4.7 93 66
220 132 22 10 Various YNa0d1 min 11.5 6.9 7.0 8.0 3.1 4.1 78 56
max 12.4 7.3 7.4 8.9 3.5 4.5 82 59
132 88 22 10 Various YNa0d1 min 10.6 6.8 6.2 7.8 3.0 4.1 72 48
max 11.2 7.2 6.4 8.4 3.4 4.3 75 54
132 66 22 10 9 to YNa0d1 min 10.3 6.7 6.2 7.5 2.9 4.1 68 46
11.7 max 11.1 7.0 6.3 8.3 3.2 4.2 71 48
132 44 22 10 11.3 YNa0d1 min 10.0 6.6 6.1 7.2 2.8 4.0 61 43
max 10.7 7.0 6.3 7.9 3.2 4.2 63 45
132 33 11 YNd1 min 9.9 6.6 6.1 7.1 2.8 4.0 59 41
max 10.4 6.9 6.3 7.6 3.1 4.2 61 44
88 44 22 10 Various YNa0d1 min 9.5 6.5 5.6 7.1 2.7 3.9 58 41
max 9.9 6.9 5.8 7.5 3.1 4.1 61 43
88 33 11 YNd1 min 9.4 6.5 5.6 7.0 2.7 3.9 53 38
max 9.8 6.8 5.8 7.4 3.0 4.1 56 40
125 275 132 22 5 11.3 YNa0d1 min 12.3 7.7 8.4 8.3 3.9 4.8 108 77
max 12.7 8.2 8.5 8.7 4.4 4.9 114 81
220 132 22 20 Various YNa0d1 min 11.5 7.6 7.5 8.0 3.8 4.6 103 74
max 11.9 8.1 7.6 8.4 4.3 4.7 109 78
160 275 88 22 20 12.5 YNa0d1 min 12.3 7.6 8.3 8.3 3.8 4.7 119 76
v 13.1 7.9 8.5 9.1 4.1 4.9 125 81
220 66 22 20 Various YNaod1 min 11.7 7.5 7.3 8.2 3.7 4.4 105 74
max 12.4 7.8 7.4 8.9 4.0 4.5 111 78
132 88 22 20 Various YNaod1 min 10.8 7.5 6.3 8.0 3.7 4.2 103 71
max 11.3 7.7 6.4 8.5 3.9 4.3 109 75
132 66 22 20 9 to YNa0d1 min 10.7 7.4 6.1 7.9 3.6 4.0 95 67
max 11.0 7.7 6.3 8.2 3.9 4.2 100 70
Notes:
Dimensions and masses in the above table are from typical designs completed in recent years and may vary from these values. Specific values might change based on specific
customer requirements.
Contact SGB-SMIT POWER MATLA to verify dimensions for specific applications.
Designs and sizes are not limited to the transformer sizes listed in the table above.
18 SMALL, MEDIUM AND LARGE POWER TRANSFORMERS T ECHNICAL DATA SHEE T S

LPT TECHNICAL DATA SHEET


MVA Nominal Voltage Rating Imped Vector Overall dimensions (m) Transformer Mass
(kV rms) of @Nom Group (Ton)
Prim Sec Ter tertiary Tap(%) A B C D E F With Oil Without
(MVA) Oil
400 132 22 20 14 YNa0d1 min 13.2 7.3 8.8 8.4 3.5 4.5 141 101
max 13.7 7.8 8.9 8.9 4.0 4.6 151 103
160 400 88 22 20 Various YNa0d1 min 13.3 7.5 9.1 8.5 3.7 4.8 181 130
max 13.8 8.1 9.3 9.0 4.3 5.0 195 140
250 400 132 22 40 14 YNa0d1 min 13.6 7.9 9.5 8.8 4.1 5.2 288 140
max 14.8 8.5 9.7 10.0 4.7 5.4 310 149
400 22 Various YNd1 min 13.4 7.7 9.3 8.6 3.9 5.0 279 199
max 14.3 8.3 9.6 9.5 4.5 5.3 300 2.7
400 15 Various YNd1 min 13.0 7.5 9.1 8.2 3.7 4.8 233 166
max 14.2 8.2 9.5 9.4 4.4 5.2 250 180
275 132 22 40 11.3 YNa0d1 min 12.1 7.4 8.2 8.1 3.6 4.6 214 148
max 13.0 8.1 8.6 9.0 4.3 5.0 230 155
220 132 22 40 Various YNa0d1 min 11.5 7.3 7.5 8.0 3.5 4.6 158 108
max 12.4 8.1 7.8 8.9 4.3 4.9 170 112
315 400 88 22 40 Various YNd1 min 13.8 7.7 9.3 9.0 3.9 5.0 300 213
max 15.9 8.3 9.4 11.1 4.5 5.1 323 224
275 132 22 40 12.5 YNa0d1 min 12.5 7.4 8.4 8.5 3.6 4.8 293 209
max 13.3 8.0 8.6 9.3 4.2 5.0 315 219
132 88 22 40 Various YNd1 min 10.8 7.3 6.8 8.0 3.5 4.7 288 206
max 11.5 7.9 7.1 8.7 4.1 5.0 310 216
500 400 132 22 40 14 YNa0d1 min 13.7 7.7 9.4 8.9 3.9 5.1 293 223
max 14.9 8.1 9.7 10.1 4.3 5.4 316 241
400 22 Various YNd1 min 13.5 7.6 9.3 8.7 3.8 5.0 279 217
max 14.3 8.0 9.5 9.5 4.2 5.2 300 228
400 11 Various YNd1 min 13.4 7.6 9.3 8.6 3.8 5.0 270 204
max 14.3 8.0 9.5 9.5 4.2 5.2 290 214
275 132 22 40 11.3 YNa0d1 min 12.5 7.5 8.5 8.5 3.7 4.9 262 200
max 13.3 7.8 8.7 9.3 4.0 5.1 282 209
275 88 22 40 12.5 YNa0d1 min 12.5 7.5 8.5 8.5 3.7 4.9 256 195
max 13.2 7.8 8.7 9.2 4.0 5.1 275 205
220 132 22 40 Various YNa0d1 min 11.9 7.5 7.8 8.4 3.7 4.9 254 193
max 12.7 7.8 8.0 9.2 4.0 5.1 273 203
630 400 220 22 20 14 YNa0d1 min
max
800 765 400 33 40 Various YNa0d1 min
max
400 275 22 40 12.5 YNa0d1 min
max
400 22 Various YNd1 min
max
400 11 Various YNd1 min
max
Notes:
Dimensions and masses in the above table are from typical designs completed in recent years and may vary from these values. Specific values might change based on specific
customer requirements.
Contact SGB-SMIT POWER MATLA to verify dimensions for specific applications.
Designs and sizes are not limited to the transformer sizes listed in the table above.
SMALL, MEDIUM AND LARGE POWER TRANSFORMERS 19
CONTACT
STARKSTROM-GERÄTEBAU GMBH SMIT TRANSFORMER SALES INC.
Regensburg • Germany Summerville, SC • USA
Phone +49 941 7841-0 Phone +1 843 871-3434

SÄCHSISCH-BAYERISCHE SGB-USA INC.


STARKSTROM-GERÄTEBAU GMBH Louisville, OH • USA
Neumark • Germany Phone +1 330 871-2444
Phone +49 37600 83-0
OTC SERVICES INC.
ROYAL SMIT TRANSFORMERS B.V. Louisville, OH • USA
Nijmegen • The Netherlands Phone +1 330 871-2444
Phone +31 24 3568-911
SGB MY SDN. BHD.
SMIT TRANSFORMER SERVICE Nilai • Malaysia
Nijmegen • The Netherlands Phone +60 6 799 4014
Phone +31 24 3568-626
SGB TRANSFORMERS INDIA PVT. LTD.
RETRASIB S.A. Chennai • India
Sibiu • Romania Phone +91 44 45536147
Phone +40 269 253-269
SGB CHINA CO. LTD.
SGB CZECH TRAFO S.R.O. Yancheng • P.R. China
Olomouc • Czech Republic Phone +86 515 88392600
Phone +420 605 164860
SGB-SMIT POWER MATLA (PTY) LTD
BCV TECHNOLOGIES S.A.S. Pretoria West • South Africa
Fontenay-le-Comte • France Phone +27 12 318 9911
Phone +33 251 532200 Cape Town • South Africa
Phone +27 21 505 3000
Subject to technical changes.

SGB-SMIT POWER MATLA


1 Buitenkant Street. Pretoria West
8 Eliot Avenue, Epping 2, Cape Town
Phone +27 12 318 9911
Fax +27 86 524 7167
COPYRIGHT 2020

e-mail [email protected]
www.sgbsmitpowermatla.com
www.sgb-smit.com

You might also like