Lecture 8. Pile Foundations
Lecture 8. Pile Foundations
Lecture 8. Pile Foundations
CONEN-452
2
Pile foundations
End bearing piles
Piles are structural members that are made of
steel, concrete or timber.
4
Pile foundations
Lateral load on piles
When subjected to horizontal forces, pile
foundations resist by bending, while still
supporting the vertical load transmitted by
the superstructure.
5
Pile foundations
Piles in expansive soils
Expansive and collapsible soils may extend to
a great depth below the ground surfaces.
7
Pile foundations
Uplifting forces on foundations
The foundations of some structures (e.g.
transmission towers, offshore platforms,
and basement mats below the water table)
are subjected to uplifting forces.
8
Pile foundations
Erosion effects on foundations
9
Steel piles
Steel piles generally are either pipe piles or rolled steel H-section piles.
Pipe piles can be driven into ground with their ends open or closed.
General facts about steel piles
Usual length: 15 – 60 m (50 – 200 ft)
Usual load: 300 kN – 1200 kN (67 – 256 kip / 33 – 128 ton)
Advantages Disadvantages
• Easy to handle with respect to • Relatively costly
cutoff and extension to the
desired length • High level of noise during pile
driving
• Can stand high driving stresses
• Subject to corrosion
• Can penetrate hard layers such
as dense gravel and soft rock • H-piles may be damages or
deflected from the vertical
• High load-carrying capacity during driving through hard
layers or past major
10
obstructions.
Concrete piles - precast
Two categories: (a) precast piles (b) cast-in-situ piles
General facts about precast concrete piles
Usual length: 10 – 15 m (30 – 50 ft)
Usual load: 300 kN – 3000 kN (67 – 675 kip / 33 – 337 ton)
Advantages
• Can be subjected to hard Disadvantages
driving
• Difficult to achieve proper cutoff
• Corrosion resistant
• Difficult to transport
• Can be easily combined with a
11
concrete superstructure
Concrete piles – precast prestressed
Precast piles can be prestressed by use of high-strength steel pre-stressing
cables.
During casting of piles, the cables are pre-tensioned to about 900-1300
MN/m2 (130-190 ksi), and concrete is poured around them.
General facts about precast prestressed concrete piles
Usual length: 10 – 45 m (30 – 150 ft)
Max length: 60 m (200 ft)
Max load: 7500 – 8500 kN (1700 – 1900 kip / 850 – 950 ton)
Advantages and disadvantages are same as those of precast piles
12
Concrete piles – cased cast-in-situ
Cast-in-situ piles are built by making a hole in the ground and then filling
it with concrete. These piles are divided into two broad categories: (a)
cased, and (b) uncased.
General facts about cased cast-in-situ concrete piles
Usual length: 5 – 15 m (15 –50 ft)
Max length: 30 – 40 m (100 – 130 ft)
Usual load: 200 –500 kN (45 – 115 kip / 22 – 57 ton)
Max Load: 800 kN (180 kip / 90 ton)
Advantages
• Relatively cheap Disadvantages
• Allow for inspection before • Difficult to splice after concreting
pouring concrete
• Thin casing may be damaged
• Easy to extend during driving
13
Concrete piles – uncased cast-in-situ
Cast-in-situ piles are built by making a hole in the ground and then filling
it with concrete. These piles are divided into two broad categories: (a)
cased, and (b) uncased.
General facts about uncased cast-in-situ concrete piles
Usual length: 5 – 15 m (15 –50 ft)
Max length: 30 – 40 m (100 – 130 ft)
Usual load: 300 –500 kN (67 – 115 kip / 33 – 57 ton)
Max Load: 700 kN (160 kip / 80 ton)
Disadvantages
Advantages • Voids may be created if concrete
is placed rapidly
• Initially economical
• Difficult to splice after concreting
• Can be finished at any elevation
• In soft soils, the sides of the hole
may cave in, squeezing the
14 concrete
15
Bored pile – defect
16
Dilemma of Bored and Driven Piles
In American/Australian literature, the word “pile” would
generally mean “the driven system”. For “bored piles”,
they use the term “drilled piers/drilled
piles/caissons/drilled shafts”.
17
Why Bored Piles are too Common in KSA ?
These are labor-intensive, and labor is cheap in KSA
18
Changes in soils during pile construction
The construction of shallow foundations do not significantly alter the
underlying soils, so pre-construction soil properties also reflect post-
construction conditions.
The process of constructing deep foundations changes the
surrounding soils, e.g., driven piles push the soil aside as they are
driven into ground, thus inducing large horizontal stresses in soil.
The remolding of the clay changes its structure and reduces its
strength to a value near the residual strength.
Current analysis techniques are based on the peak strength. An
analysis based on the residual strength might be more reasonable,
but no such method has yet been perfected.
20
Changes in clay
Nature of variation of
undrained compressive
strength, cu, with time
around a pile driven into
soft clay
21
Changes in clays
Compression and excess pore water pressure
Pile driving also compresses the adjoining soils.
If saturated clays are present, this compression generates excess pore
water pressure.
The ratio of the excess pore water pressure, ue, to the original vertical
effective stress, v’, (i.e. ue/v’) may be as high as 1.5 to 2.0 near the
pile, gradually diminishing to zero at a distance of 30 to 40 pile radii
(see figure on next slide).
The greatest compression occurs near the pile toe, so ue/v’ in that
region may be a high as 3 to 4 (Airhart et al., 1969).
These high pore water pressure dramatically decrease the shear
strength of the soil, which makes it easier to install the pile, but
temporarily decrease its load-bearing capacity.
22
Changes in clays
Compression and excess pore water pressure
24
Changes in clays
Compression and excess pore water pressure
Soft clays will probably flow back into this gap, but stiff clays
will not.
26
Changes in sand
Soil compression from advancing pile also generates excess pore
water pressure in loose saturated sands.
These excess pore water pressure dissipate very rapidly due to
higher hydraulic conductivity (permeability) of sands.
Thus the full pile capacity develops almost immediately.
Some local dilation (soil expansion) can occur when driving piles
through very dense sands.
The sand in the center of pile groups is influenced by more than one
pile, and therefore becomes denser than sand near the edge of the
group. This, in turn, probably causes the center piles to carry a large
share of the total downward load.
28
Drilled shafts
The construction methods for drilled shafts foundations are
completely different from those for piles.
Piles cause the increase in lateral earth pressure, whereas drilled
shaft construction causes decrease in lateral earth pressure.
Pile driving compresses the soil below the toe, while drilled shaft
construction does not.
Pile and drilled shafts may not develop the same side-friction and
toe-bearing resistance, even when the foundation dimensions are
identical.
If the boring is left open for an extended period, too much expansion
occurs and the load capacity can be significantly reduced.
29
Drilled shafts (contd.)
In clays, the process of drilling the hole also alters the soil
properties because the auger smears and remolds the clay. This
can reduce the shear strength and the side-friction resistance.
Drilling mud used during construction can also affect the side-
friction resistance because mud may become embedded in the
walls of boring.
30