0% found this document useful (0 votes)
48 views2 pages

Data Sheet Sensors VEK MNH

The document discusses induction loop vehicle detectors from FEIG for use in barrier systems and access control. It provides technical details on the VEK MNH1 and VEK MNH2 detectors, including their features, specifications, outputs, ordering information, and a USB interface for configuration.

Uploaded by

David Alejo
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
48 views2 pages

Data Sheet Sensors VEK MNH

The document discusses induction loop vehicle detectors from FEIG for use in barrier systems and access control. It provides technical details on the VEK MNH1 and VEK MNH2 detectors, including their features, specifications, outputs, ordering information, and a USB interface for configuration.

Uploaded by

David Alejo
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

SENSORS

VEK MNH1 / VEK MNH2

INDUCTION LOOP DETECTOR


FOR VEHICLE DETECTION
– New design with multi colored plug in terminals
– Basic settings easily adjustable with DIP switches
– Advanced settings via software
– USB interface for using modern diagnostic and
service software
– Wide AC / DC supply voltage range
– Wide temperature range
– Transistor output version for applications with
high operating cycles

FEIG Induction Loop Detectors for parking technologies Additional features:

When it comes to barrier systems, gates and bollards for access › Automatic system adjustment directly after power on
control purpose, the user‘s focus is on safety, reliability and
› Galvanic isolation between loop and detector electronics
speed.
› Sensitivity adjustment independent of loop inductivity
Besides a powerful control unit induction loop detectors for
vehicle identification play a crucial role, as several induction › Continuous readjustment of frequency drifts in order to
loops are usually installed for safety purposes and for gener- avoid environmental influences
ating commands when driving in or out.
› Quick response time
The induction loop detectors of the MNH series guarantee
› Mode ‘direction indication’ for VEK MNH2
­extremely reliable detection of the vehicles. The settings via
the DIP switches enable a simple and rapid start up. The diag- › Adjustments for relay operation – pulse & presence
nostic and service software offers a powerful tool in case
› LEDs for indication and fault detection
trouble shooting and for advance settings of functions as the
sensitivity or switching hysteresis.
Technical Data

Housing for DIN rail mounting


Material ABS Plastic, color RAL 5001 / blue (special colors on request)
Dimensions (w x h x d) 22.5 mm x 79 mm x 81 mm (without terminals)
Weight 160 g
Type of connection Color coded plugin terminals
Type of protection IP 20
Supply voltage 10 – 30 V DC or 10 – 26 V AC max. 2 W (SELV)
Temperature range -37 °C – 70 °C

Loop Characteristics

Loop supply cable up to 200 m


Inductance range 20 – 700 μH (recommended 100 – 300 μH)
Operating frequency 30 – 130 kHz
Sensitivity range 0.01 – 0.64 % Δf/f (4 steps with DIP switches)
0.01 - 2.55 % Δf/f (255 with service software)

Signal Outputs (Relay Version)

VEK MNH1-R24 1 presence relay with changeover contact (signal output invertible),
1 pulse relay with changeover contact (signal output invertible)
VEK MNH2-R24 1 relay per channel with NO contact (signal output invertible)
Switching power max. 60 W / 125 VA
Switching voltage max. 48 V (AC/DC)
Switching current max. 2 A

Signal Outputs (Transistor Version)

VEK MNH2-O24 1 NO-Collector presence output per channel (signal output invertible),
1 NO-Collector loop fault per channel (signal output invertible)
Switching voltage Vbb max. 27 V DC (SELV)
Switching current max. 25 A

Order Descpriptions

5013 VEK MNH1-R24-A 1-channel, DIN rail mounting, relay outputs


5014 VEK MNH1-R24-A LL10 1-channel, DIN rail mounting, relay outputs, delivery lot size: 10
5019 VEK MNH2-R24-C 2-channel, DIN rail mounting, relay outputs
5020 VEK MNH2-R24-C LL10 2-channel, DIN rail mounting, relay outputs, delivery lot size: 10
5159 VEK MNH2-O24-D 2-channel, DIN rail mounting, open collector outputs
5160 VEK MNH2-O24-D LL10 2-channel, DIN rail mounting, open collector outputs,
delivery lot size: 10
4405 VEK MNE USB-cable USB-cable for connection detector to computer
Diagnostic and Service Software (free of charge)

FEIG ELECTRONIC GmbH Information updated: Mai 2020. The information in this document is subject to change