Problem
This document lists the available upgrades and updates for the Hardware Management Consoles that manag
i, AIX, and POWER linux partitions.
HMC Upgrades
Target Upgrade Upgrade Updates Date End of Models POWER
Version From Instructions Available Service supported Support
V9 R2 V9 R1 ppc link 11/20/2020 7063-CR1 P9, P8, P7
7042-CR9
x86
https://www.ibm.com/support/pages/recommended-fixes-hmc-code-upgrades 2/8
05/05/2021 Recommended Fixes - HMC Code Upgrades
7.7.1 C04-C08 P5
V7.7.2 V6.1.3 and link link 09/17/2010 09/30/2012 CR2-CR6 P7, P6
earlier C04-C08 P5
Support Downloads Documentation Forums Cases Monitoring
V7.7.1 V7.3.x link link 02/19/2010 02/29/2012 CR2-CR5 P7, P6
C04-C08 P5
Manage support account
V7.3.5 V7.3.x link link 10/30/2009 10/31/2011 CR2-CR5 P6, P5
C03-C07
V7.3.5 V6.1.3 and link link 10/30/2009 10/31/2011 CR2-CR4 P6, P5
earlier C03-C07
V7.3.4 V6.1.3 or link link 11/21/2008 11/30/2010 CR2-CR4 P6, P5
later C03-C07
V7.3.3 V7.3.1 or link link 08/25/2008 05/31/2010 CR2-CR4 P6, P5
V7.3.2 C03-C07
V7.3.2 V7.3.1 link link 11/16/2007 10/31/2009 CR2-CR4 P6, P5
C03-C06
V7.3.1 V6.1.2 or link link 06/12/2007 05/31/2009 CR2-CR4 P6, P5
Target Version:
The version of HMC to upgrade to.
Upgrading From:
The versions of HMC that can directly upgrade to the target release in one step. Versions older then those li
Upgrade Instructions:
Link to the instructions on how to obtain the upgrade images and perform the upgrade.
Updates:
Link to the instructions on how to obtain and install fixes for the current release.
Date Available:
Approximate date the version/release was first made generally available for use.
End of Service:
The date that fix support ends for the target release.
Models supported:
List of HMC models that support the target release. Entries in bold indicate a change in support; the first re
last release to support a model whose support has ended. Machine type 7315 supported ended in 6.1.3. Mod
V8.8.3.0.1; 7042-OE2 requires a minimum of V8.8.6.0. For further information on HMC hardware support
http://www14.software.ibm.com/webapp/set2/sas/f/power5cm/supportedcodeHMCHW.html
https://www.ibm.com/support/pages/recommended-fixes-hmc-code-upgrades 3/8
05/05/2021 Recommended Fixes - HMC Code Upgrades
Power Support:
Indicates the family of IBM POWER servers this HMC can manage: P9 is POWER9; P8 is POWER 8; P7 P
POWER5. Downloads
Support model/types,
Specific server hardware
Documentation Forums
feature Cases
codes or firmware included
Monitoring
features in that family
the minimum HMC release or service pack required.
HMC Model-specific Firmware Updates Manage support account
For certain HMC Machine Type/Models (MTMs), IBM recommends updating the HMC firmware with the
fixes are installed. See: http://www14.software.ibm.com/webapp/set2/sas/f/hmcl/bios/home.html
HMC Code Levels and Server Firmware Compatibility
The design goal is that a HMC can, at a minimum, connect to and perform a server firmware upgrade or up
that has a server firmware level that is at an equivalent or earlier level then the HMC. In general, upgrade th
firmware to a recommended level soon after the HMC upgrade. Always check the HMC and server firmwar
release specific exceptions or special instructions. Click here for a complete list of supported combinations
server firmware levels.
HMC Code Levels and IBM i OS compatibility
HMC upgrades have no minimum IBM i OS requirement. New HMC functions specific to IBM i, for exam
shutdown option, may require a minimum IBM i release or PTF level to use. Check the HMC release notes
center for feature specific requirements.
https://www.ibm.com/support/pages/recommended-fixes-hmc-code-upgrades 4/8
05/05/2021 Recommended Fixes - HMC Code Upgrades
From the HMC or remote GUI session log in to the HMC, Select the Welcome option in the navigation area
The HMC code version will be displayed in a pop-up box as illustrated below:
https://www.ibm.com/support/pages/recommended-fixes-hmc-code-upgrades 5/8
05/05/2021 Recommended Fixes - HMC Code Upgrades
Click on Help and About from the menu of the HMC main interface. A window shows the installed version
A list of all of the applied PTFs is included. This information cannot be displayed from a remote WebSM se
In the navigation area, expand Licensed Internal Code Maintenance, and select HMC Code Update. In the S
version, build level, and PTF list can be viewed. To view the entire list of installed fixes, it might be necessa
https://www.ibm.com/support/pages/recommended-fixes-hmc-code-upgrades 6/8
05/05/2021 Recommended Fixes - HMC Code Upgrades
Document Information
More support for:
Power HMC
https://www.ibm.com/support/pages/recommended-fixes-hmc-code-upgrades 7/8
05/05/2021 Recommended Fixes - HMC Code Upgrades
Software version:
7.7.9, 8.8.1, 8.8.2, 8.8.3, 8.8.4, 8.8.5, 8.8.6
number:
DocumentDownloads
Support Documentation Forums Cases Monitoring
667847
Manage support account
Modified date:
26 March 2021
https://www.ibm.com/support/pages/recommended-fixes-hmc-code-upgrades 8/8