Cable NBR/NBR | NBR | H01N2-D | NBR/NBR (AWG) | NBR (AWG)

NBR RUBBER DOUBLE INSULATED EXTRA FLEXIBLE COPPER WELDING CABLE (AWG SIZE)

ESZRW\U1OPZSAb`cQbc`S ESZRW\U1OPZSBSQV\WQOZ2ObO
1]\RcQb]`( 4WfSRW\abOZZObW]\ ( -30°c to max.+ 90°C
Welding Cable has a rope lay Class K stranded soft <][W\OZd]ZbOUS ( 600 V
drawn bare copper conductor per ASTM B-172.
BSabd]ZbOUS ( 3000 V
AS^O`ObW]\( ;SQV\WQOZ^`]^S`bWSa( Tensile strength = 10 N/mm2 Min.
Polyester tape (25 to 30) Micron
Elongation = 300 Min.
=cbS`AVSObV(
;W\PS\RW\U`ORWca ( 4 x cable diameter
NBR Rubber Double Sheath, black and oil resistant
4ZO[S^`]^OUObW]\ ( Flame retardant test
*Any other Color on specific request can also be supplied
as per IEC 60332-1

ESZRW\U1OPZSTSObc`Sa
• Ultra high performance flexible welding lead, double insulated for longer life and added safety
• Excellent flexibility to last longer in flex applications
• RoHS Compliant
• Outstanding toughness & durability
• High resistance to cuts, tears & abrasion
• Resistance to oil, solvents and chemicals
• Excellent ozone and weather resistant

ESZRW\U1OPZS/^^ZWQObW]\
Welding Cable is for use on connections from electrode holders and clamps to arc welders, bus welding box
or transformers. Welding cable is for applications up to 600 volts and temperatures from -30°C to +90°C.

AbO\RO`RZS\UbVQOPZS^OQYW\U(
Coils 100, 200, 300 and 500 m. in wooden reels
TECHNICAL INFORMATION
Max. Max.
Cross Outer
Copper Inner Conductor Current
Sectional Dia
Construction Dia. Resistance (Amb. Temp
Area Appx.
DWÝ& RIÝ&

AWG Nos. X Dia. mm mm mm ŸNP AMPS


6 273 X 0.254 8.00 10.70 1.39 115
4 427 X 0.254 9.50 12.10 0.873 150
2 651 X 0.254 11.00 14.20 0.554 205
1 817 X 0.254 11.70 15.40 0.44 240
1/0 1045 X 0.254 12.30 16.30 0.349 285
2/0 1330 X 0.254 14.40 18.70 0.276 325
3/0 1672 X 0.254 16.60 20.80 0.221 380
4/0 2146 X 0.254 18.20 23.00 0.175 440
250MCM 2508 X 0.254 21.10 27.60 0.149 495
350MCM 3496 X 0.254 20.80 30.80 0.106 680
500MCM 5013 X 0.254 26.80 34.00 0.0743 720

• The number of wires is approximate and wire diameter is nominal; they shall be such as to satisfy the requirements of conductor resistance of UL-83.
• In view of continuous improvements in our design and process, specifications given here in are subject change without notice.

> All are flexible conductor


> Insulation material is NBR
> Sheath material is NBR
length in feet for total circuit for secondary voltages only – do not use this table for 600 Volt in-line applications
AMPS 100' 150' 200' 250' 300' 350' 400'
100 4 4 2 2 1 1/0 1/0
150 4 2 1 1/0 2/0 3/0 3/0
200 2 1 1/0 2/0 3/0 4/0 4/0
250 1 1/0 2/0 3/0 4/0
300 1/0 2/0 3/0 4/0
350 1/0 3/0 4/0
400 2/0 3/0
450 2/0 4/0
500 3/0 4/0
550 3/0 4/0
600 4/0
REQUIRED CABLE SIZES SHOWN IN AWG NUMBERS

• The total circuit length includes both welding and ground leads (based on 4-volt drop) 60% duty cycle.

www.jainsoncablesindia.com | www.jainsoncables.com
Welding
Cable NBR/NBR | NBR | H01N2-D | NBR/NBR (AWG) | NBR (AWG)

NBR INSULATED EXTRA FLEXIBLE COPPER WELDING CABLE (AWG SIZE)

ESZRW\U1OPZSAb`cQbc`S ESZRW\U1OPZSBSQV\WQOZ2ObO
1]\RcQb]`( 4WfSRW\abOZZObW]\ ( -30°c to max.+ 90°C
Welding Cable has a rope lay Class K stranded soft <][W\OZd]ZbOUS ( 600 V
drawn bare copper conductor per ASTM B-172.
BSabd]ZbOUS ( 3000 V
AS^O`ObW]\( ;SQV\WQOZ^`]^S`bWSa( Tensile strength = 10 N/mm2 Min.
Polyester tape (25 to 30) Micron
Elongation = 300 Min.
=cbS`AVSObV(
;W\PS\RW\U`ORWca ( 4 x cable diameter
NBR Rubber Sheath, black and oil resistant
4ZO[S^`]^OUObW]\ ( Flame retardant test
*Any other Color on specific request can also be supplied
as per IEC 60332-1

ESZRW\U1OPZSTSObc`Sa
• Ultra high performance flexible welding lead, double insulated for longer life and added safety
• Excellent flexibility to last longer in flex applications
• RoHS Compliant
• Outstanding toughness & durability
• High resistance to cuts, tears & abrasion
• Resistance to oil, solvents and chemicals
• Excellent ozone and weather resistant

ESZRW\U1OPZS/^^ZWQObW]\
Welding Cable is for use on connections from electrode holders and clamps to arc welders, bus welding box
or transformers. Welding cable is for applications up to 600 volts and temperatures from -30°C to +90°C.

AbO\RO`RZS\UbVQOPZS^OQYW\U(
Coils 100, 200, 300 and 500 m. in wooden reels
TECHNICAL INFORMATION
Max. Max.
Cross Outer
Copper Nominal Conductor Current
Sectional Dia
Construction Thickness Resistance (Amb. Temp
Area Appx.
DWÝ& RIÝ&

AWG Nos. X Dia. mm mm mm ŸNP AMPS


6 273 X 0.254 2.00 9.10 1.39 115
4 427 X 0.254 2.00 10.60 0.873 150
2 651 X 0.254 2.00 11.80 0.554 205
1 817 X 0.254 2.10 13.50 0.44 240
1/0 1045 X 0.254 2.20 13.70 0.349 285
2/0 1330 X 0.254 2.40 16.20 0.276 325
3/0 1672 X 0.254 2.60 18.20 0.221 380
4/0 2146 X 0.254 3.00 21.60 0.175 440
250MCM 2508 X 0.254 3.20 24.00 0.149 495
350MCM 3496 X 0.254 3.40 26.30 0.106 680
500MCM 5013 X 0.254 3.50 29.20 0.0743 720

• The number of wires is approximate and wire diameter is nominal; they shall be such as to satisfy the requirements of conductor resistance of UL-83.
• In view of continuous improvements in our design and process, specifications given here in are subject change without notice.

> All are flexible conductor


> Insulation material is NBR

length in feet for total circuit for secondary voltages only – do not use this table for 600 Volt in-line applications
AMPS 100' 150' 200' 250' 300' 350' 400'
100 4 4 2 2 1 1/0 1/0
150 4 2 1 1/0 2/0 3/0 3/0
200 2 1 1/0 2/0 3/0 4/0 4/0
250 1 1/0 2/0 3/0 4/0
300 1/0 2/0 3/0 4/0
350 1/0 3/0 4/0
400 2/0 3/0
450 2/0 4/0
500 3/0 4/0
550 3/0 4/0
600 4/0
REQUIRED CABLE SIZES SHOWN IN AWG NUMBERS

• The total circuit length includes both welding and ground leads (based on 4-volt drop) 60% duty cycle.