25 Kva 1ø LV Box With Meter Box TN-2827
25 Kva 1ø LV Box With Meter Box TN-2827
25 Kva 1ø LV Box With Meter Box TN-2827
HV 75 OIL °C 35
BIL (kV Peak) TEMP. RISE
LV NA WDG °C 40
105
HV 3.94 MASS OF OIL kg 41
CURRENT (A)
LV 104.17 TOTAL MASS kg 219
FREQUENCY Hz 50 VOLUME OF OIL Ltr 49
VECTOR GROUP 1-PHASE MONTH & YEAR OF MFG. /2023
/2024
IMPEDANCE VOLT % 4 SERIAL NO. *
DISPATCH DATE - EXPIRY DATE G.P. -
CONDUCTOR MATERIAL HV FUSE RATING amp 10
175
ALUMINIUM
CUSTOMER - JVVNL
P.O. No.
MADE IN INDIA
SUBTRACTIVE POLARITY
Signal Light
1.1 2.1
ICB
2.1 2.2(n)
70
1.1 1.2(N)
HV FUSE LINK
1.2(N) 2.2(n)
105
3- MATERIAL - STAINLESS STEEL 0.9 WITH TOLERANCE ± 0.1 MM. THICK. DRN BY
00
DRAWING No.
5 14
11
d
'*' MARKED ITEM NOT PROVIDED AT THE TIME OF TESTING.
B
HV SIDE SIDE VIEW LV SIDE 20 TECHNICAL PLATE * 1
(MOUNTING) 19 ANTI-THEFT SS BOLT * 1
18 OIL FILLING HOLE WITH COVER (141") 1
19 14
17 THERMOMERTER POCKET 1
16 OIL LEVEL GAUGE 1
17 15 LIFTING LUGS 2
18 14 POLE MOUNTING BRACKET 2
Tank Inside Dimensions (mm) Weights/Qty (kg) 13 SIGNAL LIGHT * 1
TRANSFORMER OIL ltrs 49 12 INTERNAL CIRCUIT BREAKER HANDLE 1
Diameter (d) 450 11 TANK EARTHING TERMINAL 2
TOTAL TRANSFORMER 219
Height (h) 630 10 PRESSURE RELIEF DEVICE 1
W
TRANSFORMER OIL 41
9 L.V. BUSHING 2
Overall Dimensions (mm) TANK & FITTINGS 41 8 TOP COVER CLAMP 1
INTERNAL ASSEMBLY 137
1.1 Height (H) 990 7 H.V. NEUTRAL BUSHING 1
Min. Air Clearances (mm) 6 H.V. BUSHING 1
4 Breadth (B) 660
VOLTAGE H.V. L.V. 5 RATING & TERMINAL MARKING PLATE 1
2 Width (W) 600 PHASE TO PHASE NA NA 4 H.V. TERMINAL MARKING
1
SET
PHASE TO EARTH 140 40/20 (box inside)
3 L.V. TERMINAL MARKING
1
TOP VIEW SET
2 EARTHING TERMINAL (LV BOX) * 2
1 LV CABLE BOX 1
S. NO. DESCRIPTION QTY
MANGAL ELECTRICAL INDUSTRIES PVT. LTD.
Note:- OUTLINE GENERAL ARRANGEMENT DRAWING
1. ALL DIMENSIONS ARE IN MM. TOLERANCE +/- 10%.. Rating 25 KVA
2. THIS DRAWING SHOWS ONLY GENERAL DISPOSTION OF FITTINGS. KV Class 11/ 3/0.240 KV, 1Ø, 50 Hz
3. TANK SIDE PLATE - 2.0 mm. Thk. M.S. DOC No. DWG No. OGA/25/01 REV. 0
TOP & BOTTOM PLATE - 2.5 mm. Thk. M.S. NAME DATE SCALE CUSTOMER :
DRN. BY MITESH 04-08-2023 N.T.S. DATE
4. PAINT SHADE : OLIVE GREEN COLOR CONFORMING TO NO. 220 OF IS : 5/1961.
CHD. BY AMIT REV. 01
APPR. BY AMIT REV. 02
B
C
A
E D
MATERIAL - AMORPHOUS CORE
Dimensions
(MM)
FLUX DENSITY CALCULATION
A 260
CORE DIMENSION :-
B 90
WIDTH - 213 mm.
STACK - 44.5 mm. C 44.5
4.44 x 50 x 16303.02 x 48 25 KVA, 11/√3/0.240 KV, 1Ø, 50 Hz, ONAN, DISTRIBUTION TRANSFORMER
Buyer's Reference:
ALUMINIUM WOUND Scale
- AMORPHOUS CORE N.T.S.
Notes :- ENERGY EFFICIENCY LEVEL 1 DATE : 30.03.22 REV.No.
00
DRAWING No.
NOTE :
q1 CALCULATED IS LESS THAN q 2 SPECIFIED IN IS 2026 (Part 5) : 2011
MANGAL ELECTRICAL INDUSTRIES PVT LTD, JAIPUR
HEAT DISSIPATION CALCULATION OF 25 KVA - 6.351/0.24 - 1Ø TRANSFORMER
Transformer is capable of giving continuous rated output without exceeding the specified
temperature rise because losses dissipated by tank are more than losses to be dissipated.
174
30 30 117
30 30
237
2 NOS. MA FLAT 50X8 mm at L=553 MM (1.736 KG Each)
NOTE:
1. All Dimension in MM.
MANGAL ELECTRICAL INDUSTRIES PVT. LTD.
2. Not to Scale the Drg. CLAMP FOR MOUNTING
Rating 25 KVA
3. Hole size 17.5 mm. KV Class
DOC No. DWG No. LV/25/02 REV. 0
4. If Transformer installed at 4 Meter Height from groung level.
NAME DATE SCALE CUSTOMER :
DRN. BY MITESH 04-08-2023 N.T.S. DATE
CHD. BY AMIT REV. 01
APPR. BY AMIT REV. 02
30 177 30
L-ACCORDING L-ACCORDING
TO SIZE OF TANK TO SIZE OF TANK
237
237
100
25
TANK OF 1- Ø 25 KVA TRF
MANGAL ELECTRICAL INDUSTRIES PVT. LTD.
NOTE:
Rating 25 KVA
1. All Dimension in MM.
KV Class
2. Not to Scale the Drg. DOC No. DWG No. LV/25/03 REV. 0
3. Hole size 17.5 mm. NAME DATE SCALE CUSTOMER :
DRN. BY MITESH 04-08-2023 N.T.S. DATE
4. MS Flat 50x8 mm. CHD. BY AMIT REV. 01
APPR. BY AMIT REV. 02
TANK WALL
1 8
M12
1
7 2
4
6
METER
5
3
SIDE VIEW
FRONT VIEW SIDE VIEW
LV CABLE BOX WELDED
WITH TANK WALL
Description
10 KVA 8 LUGS -
Cat No / Thk Qty. 7 METER 1
Lugs for LT Terminal 7043 / 2 mm 4
GLASS (SIZE 115X150X6 MM) FOR METER
6 1
Outgoing LT Terminals 1.1 KV / 250 A 2
5 SLIDING COVER WITH GLASS 1
Terminals ends for Meter ACP-254 / 10x2mm 4
4 OUTGOING BUSHING 2
3 BODY EARTHING TERMINAL (M10 BOLT) 2
25 KVA
Description 2 PVC COVERED CABLR -
Size
Copper Flexible Cable LT Terminal to
1 LV CABLE BOX WITH METER DISTRIBUTION BOX -
70² MM
Meter & Outgoing Bushings
S. NO. DESCRIPTION QTY
Electrical Clearance Inside MANGAL ELECTRICAL INDUSTRIES PVT. LTD.
Box min LV BOX WITH METER BOX FOR SINGLE PHASE TRANSFORMER
Rating 25 KVA
P-E 20 mm
KV Class 6.351/.240 KV, 1Ø, ONAN, DISTRIBUTION TRANSFORMER
NOTE: DOC No. DWG No. REV. 0
TOP VIEW ALL DIMENSTION ARE IN MM & TOLERANCE +- 5 % DRN. BY
NAME
MITESH
DATE
08-07-2023
SCALE
N.T.S.
CUSTOMER :
DATE
CHD. BY AMIT REV. 01
APPR. BY AMIT REV. 02