OpenLab CDS 2.6 QuickReferenceSheet
OpenLab CDS 2.6 QuickReferenceSheet
Access Instruments and Projects Acquire Data Analyze and Report Data
CONTROL PANEL CREATE ACQUISITION METHOD REVIEW DATA
Use the Desktop icon to launch OpenLab Control Panel. Define acquisition and instrument parameters for runs using this To load data, double-click node in the Data Selection view
method. Pin injections or result sets for comparison
Download to instrument to use new parameters immediately. Use Peak Explorer to view a sequence at a glance and
MANAGE USERS
identify trends or artifacts.
ROLE: SYSTEM ADMIN Create custom result sets based on existing injections (right-click
Assign users to groups
RUN A SINGLE SAMPLE
nodes in the injection tree to add them, click Create new Result Set
Assign roles to groups Enter sample parameters in the ribbon).
Use default roles or assign privileges to roles Include acquisition method
Use the Integration Optimizer to quickly adjust peak baselines.
(use role Chemist for Acquisition and Data Analysis) Optional: Include processing method
Edit security policy Run
Manage licenses INJECTIONS AND PROCESSING METHODS
A processing method may already be linked (assigned) to the data.
RUN A SEQUENCE
If not, create new master method
PROJECTS Create a new sequence, or Link injections to the master processing method
Open and edit a previously saved sequence, or
ROLE: PROJECT ADMIN A result set method (stored in result set folder) is generated
Import a CSV file (also possible via drag and drop), or
Create projects to organize your data: on linking the master method to the injections.
From a result set, or
Activate method audit trails Click Apply Template to apply a sequence creation template Reprocess (automatic after linking, or manually)
Apply project-specific options
SEQUENCE
Add custom parameters for samples and compounds EDIT PROCESSING METHOD
Edit sequence table:
Right-click and use Fill-down to edit rows, copy/paste entire rows, Processing methods are divided in sections: e.g.
Create shortcut for Data Analysis with a project.
pin columns at the front Integration Events for all or for specific signals
Launch Data Analysis for a project. Edit injections and sequence parameters: Compounds:
For automated processing and reporting: enter existing processing Add compounds: Right-click a peak, or right-click the compound table.
method Calibration: Set number of calibration levels in the General tab
INSTRUMENTS
Define name of the result set Spectra: MS or UV reference spectra for confirmation or purity checks
ROLE: INSTRUMENT ADMIN Extraction > Spectrum: Background correction settings
Create and configure instruments SEQUENCE CREATION TEMPLATE
Tools > Custom Calculation: Extend default calculations
Monitor instruments Create a new template in the Sequence Creation Template window: