AN INEXPENSIVE SOLUTION
Heating by means of fan heaters as an extre-mely
inexpensive investment if the invested sum per instal-
led kilowatt is calculated. The reason for this is that fan
heaters often provide more power per appliance than,
for example, radiant heating. Cabling is simpler as the
appliances are mounted on a wall or are portable with
connecting cables.
Elektra V is for use on ships and within the offshore industry, withstands vibrations and humidity. Approved by Det
Norske Veritas.
DIMENSIONS
300 340
MOUNTING ACCESSORIES
Elektra is primarily intended for wall mounting, but the Type Description
brackets can be angled for portable use.
ELSRT Control panel and thermostat, for ELC/ELV,
start/stop
The heat output is controlled by the built in thermostat
(+5 – +35°C). Elektra H has a thermostat with setting range 0 – 70°C. ELS Control panel, for ELF, start/stop
ELRT Thermostat, for ELH
The on/off mode, and half or full heat output can be
controlled with the output selector on the unit or with an external
control panel mounted on to the wall for easy access.
APPROVAL/AREA OF USE
The heaters are approved by Det Norske Vertias, certificate No. E-4834 for use on board ships and offshore units, tightness IP44.
Regulation Weight
El. nr. Type Power Volt/fase Airflow m3/h A ∆t m/s
kW kg
4927716 EVN3-44 3 kW 440/3 60Hz 1,5 - 3,0 1500 17 3,95 5,8 3,5
4927717 EVN 6-44 6 kW 440/3 60Hz 3,0 - 6,0 1500 20 9,7 11,6 3,5
4927718 EVN 9-44 9 kW 440/3 60Hz 4,5 - 9,0 1500 21 11,8 17,4 3,5
396
8 4
495
Min
200
10
Product: El. heater IP 44
Type: EVN 9 - 44
El data: 9kW 440/3 60Hz
Air data: 1300 m3/h Max outlet 40ºC
Producer: Thermo Byggvarme AS
WARNING:
9
Do not cover
Free space in front min, 0,5 m
keep the inlet and outlet grid clean
Reset safety switch:
Disconnect el. supply. Remove cover.
160
160
355
390
380
7
6
5 3 Min
1 2 200 247 248 Min. 500
Cable glands for service
Top view Side view Front view
ELECTRICAL INSTALLATION
Electrical installations must be carried out by an authorised electrical contractor. Support cable and any extra cable for external
thermostat and remote control switch may be of standard marine type. Make sure that the screws in terminal are properly
tightened on both sides. Check for correct function of the fan and the two groups. Operate the regulation switch and the
thermostat.
MAINTENANCE
Regular maintenance is normally not necessary.
Thick layers of dust on the surface of the heater constitute a fire hazard.
Check the inlet and outlet grids for dirt, and clean with pressure air.
REPAIRS
Repair s must only be carried out by an authorised electrical contractor.
When ordering spare parts, it is important to specify the correct type of heater, output and voltage, as well as the production date
and description of the spare part.
SPARE PARTS
You will find this described in the wiring diagram inside the cover.