0% found this document useful (0 votes)
4 views4 pages

Tbcp2 30k400 Manual

Download as pdf or txt
Download as pdf or txt
Download as pdf or txt
You are on page 1/ 4

V1.

0
TBCP2-30K400
RF CURRENT MONITORING PROBE

1 Introduction

The TBCP2-30K400 is a snap-on RF current monitoring probe, expanding the Tekbox product
range of affordable EMC pre-compliance test equipment.
The probe has a very flat response from 30kHz to 400 MHz and is characterized over the
frequency range from 10 Hz to 500 MHz. The TBCP5-30K400 is for RF current monitoring
applications that need higher sensitivity in the low frequency range, compared to our other
current monitoring probe series. The higher sensitivity at low frequencies comes at the cost of
a slightly reduced overall trans-impedance.

Picture 1: TBCP2-30K400 RF current monitoring probe

The aperture of the RF current monitoring probe is 32 mm. Its transfer impedance is 3 dB
Ohm with a 3dB bandwidth from 30kHz to 400 MHz.

1
V1.0
TBCP2-30K400
RF CURRENT MONITORING PROBE

2 Specification

Characterized frequency range: 10 Hz to 500 MHz


Aperture diameter: 32 mm
Outside diameter: 73 mm
Height: 20 mm
Weight: 320 g
Connector type: N female
Transfer impedance: 2 dB Ohm with a 3 dB bandwidth from 30 kHz to 400 MHz
Max. primary current (DC - 400 Hz): 25 A
Max. primary current (RF): 2 A
Max. core temperature: 125 °C

3 Transfer impedance

Figure1: typical transfer impedance

2
V1.0
TBCP2-30K400
RF CURRENT MONITORING PROBE

4 Typical transfer impedance table

The table below shows typical transfer impedance data of a TBCP2-30K400 current probe.
Each current probe is delivered with its corresponding measurement protocol. This data can
be used for the creation of a correction file for EMCview or similar EMC measurement
software. The transfer impedance in dBΩ subtracted from the analyzer reading in dBµV gives
the corrected reading in dBµA.
Refer to the application notes of EMCview on how to create a current probe correction file.

Frequency [MHz] transfer impedance [dBΩ] Frequency [MHz] transfer impedance [dBΩ]
0.00001 -62.61 10 3.1
0.000025 -58.59 25 3.1
0.00005 -52.37 50 2.97
0.000075 -48.81 75 2.87
0.0001 -46.31 100 2.69
0.00025 -38.71 125 2.64
0.0005 -32.82 150 2.52
0.00075 -29.22 175 2.41
0.001 -26.78 200 2.25
0.0025 -18.91 225 2.1
0.005 -13.03 250 1.96
0.0075 -9.68 275 1.79
0.01 -7.38 300 1.56
0.025 -1.15 325 1.24
0.05 1.15 350 1.1
0.075 2.32 375 0.71
0.1 2.64 400 0.29
0.25 3.01 425 -0.11
0.5 3.1 450 -1.35
0.75 3.1 460 -1.93
1 3.12 470 -2.24
2.5 3.11 480 -2.1
5 3.1 490 -1.14
7.5 3.1 500 -0.5

Table1: Transfer impedance: 10 Hz to 400 MHz, typical data

3
V1.0
TBCP2-30K400
RF CURRENT MONITORING PROBE

5 Accessory

Tekbox supplies a calibrator corresponding suitable for the TBCP2-30K300 current probe:

Picture 2: TBCP2-CAL RF current probe calibration fixture

6 Ordering Information

Part Number Description


Snap on RF current monitoring probe, beech-wood box,
TBCP2-30K400
calibration protocol 10 Hz – 500 MHz
TBCP2-CAL Calibration fixture for TBCP2-30K400 current probe

7 History

Version Date Author Changes


V 1.0 20.10.2020 Mayerhofer Creation of the preliminary document

www.tekbox.com
TekBox Digital Solutions Vietnam Pte. Ltd.
Factory 4, F5, Lot I-3B-1, Saigon Hi-Tech Park, Tan Phu Ward, District 9, Ho Chi Minh City, Vietnam