UV-2000S Ultraviolet Transmittance Analyzer: One Touch Sample Analysis Results in Less Than Five Seconds
UV-2000S Ultraviolet Transmittance Analyzer: One Touch Sample Analysis Results in Less Than Five Seconds
UV-2000S Ultraviolet Transmittance Analyzer: One Touch Sample Analysis Results in Less Than Five Seconds
UV-2000S Ultraviolet
Transmittance Analyzer
One touch sample analysis
Results in less than five seconds
Advanced
Labsphere’s UV-2000S incorporates the latest
component and software technology to achieve
accurate in-vitro SPF/UVA-Protection Factor analysis of
sun care products developed to receive the “very high”
sun protection label. Driven by rapidly evolving industry
requirements to simplify product labeling and new
in-vitro methods to validate product UVA Protection,
the UV-2000S is designed to comply with recently
approved in-vitro methods, such as COLIPA UVA-PF,
ISO 24443, Boots Star Rating and the US FDA, as well
as several pending global standards/methods.
Value:
Fast • One touch sample analysis
The UV-2000S rapidly measures the diffuse
Results in less than five seconds
transmittance of sunscreen samples in the ultraviolet
• Updated software
wavelength region from 250 - 450 nm. Labsphere’s
Spectralon® integrating sphere incorporates a Easy-to-use menu driven application
re-optimized xenon flash lamp to provide exceptional • Automatic calculations
diffuse illumination of the product sample and minimize SPF, UVA to UVB ratio, critical wavelength
data integration time. New high performance diode FDA 2011 Testing Method, COLIPA Method,
array spectrometers coupled by new advanced fiber Boots Star Rating
optics are optimized at the system level for low stray • Easy and accurate sample positioning
light with superior wavelength stability and
• Manual stage positions for pre and
flash-to-flash repeatability.
post irradiation
• New wavelength standard captures
six relevant spectral bands
• Accurate, repeatable measurements
• Simple instrument performance
validation routine
www.labsphere.com | [email protected] © 2022 Labsphere, Inc. All Rights Reserved PB-13090-000 Rev 03
Easy to operate
A built-in report function generates essential information at
the click of a button. Reports include necessary information
such as date, time, operator name, sample identification, and
test parameters. Reports are conveniently viewed on your PC,
printed, or exported as text to data processing software for
further review and analysis.
www.labsphere.com | [email protected] © 2022 Labsphere, Inc. All Rights Reserved PB-13090-000 Rev 03
Ordering Information
Model Name Order Number
UV-2000S AA-00909-000
UV-2000S Control Software AS-02755-001
50 HelioScreen HD6 Plates PP-02101-000
Optional Accessories
UV-2000S Starter Kit: AS-02796-000
HelioScreen HD6 Plates: PP-02097-000
Specifications
Wavelength Range: 250 to 450 nm*
Wavelength Accuracy: ±1 nm
Bandwidth: (FWHM) < 4 nm
Wavelength Step: (Data Interval) 1 nm
Optical Geometry: Hemispherical Illumination/0o viewing (d/O)
Integrating Sphere Geometry: Spectralon®
Integrating Sphere Port Area: < 5%
Sample Exposure Area: 0.79 cm2
Lamp: Xenon Flash Lamp
UV Dose Per Measurement Cycle: < 0.2 J/cm2
Sample Positioning Stage: Manual Stage
Measurement Range:
Transmittance: 0 - 100%
Absorbance: 0 - 2.7 A (Dual Doped PMMA Method)
SPF: 1 - 50+
Scan Time: <5s
Measurement Methods Supported:
Bare Substrate Analysis and Data Archival: Yes
SPF: Yes
UVA/UVB: Yes
Critical Wavelength: Yes
UVA Protection Factor: COLIPA Method (2011)** Yes
UVA Protection: Revised Boots Star Rating (2011)** Yes
Broad Spectrum & UV1/UV: FDA (2011) & FDA (2019) Yes
UVA Photoprotection Method: ISO 24443 Yes
Computer Interface: USB
Minimum Computer Requirements: 1.6 GHz processor, Windows® 7, 8, 10
SVGA 800 x 600
256MB RAM, 400MB free disk space
Power Requirements: 110 - 120/220 - 240 VAC, 60/50 Hz
Operating Environment: 00 - 500 C, 0% - 70% RH (non-condensing)
Dimensions:
With Stage: 11H x 22.6D x 12.3W In (27.9H x 56.6D x 31.2W cm)
Without Stage: 11H x 12.6D x 12.3W in (27.9H 32.0D x 31.2W cm)
* All system specifications are based on a wavelength range of 290 to 400 nm.
** Requires a separate solar simulator
www.labsphere.com | [email protected] © 2022 Labsphere, Inc. Spectralon® is a Registered Trademark of Labsphere, Inc. All Rights Reserved PB-13090-000 Rev 03