Ficha Tecnica ZR y ZT Atlas Copco
Ficha Tecnica ZR y ZT Atlas Copco
Ficha Tecnica ZR y ZT Atlas Copco
Cooling
ZR After Weigh Weigh
Water Sound Dimensions
Watercooled Free air Installed cooler with witht
con pressure
oil-
oil-free delivery motor approach L.V. H.V
sump-
sump- level
compressors temp motor motor A B C
tion
Type l/s ㎥/min cfm kW l/s C db(A) kg kg mm mm mm
60hz-
60hz-8.6 bar(e)
ZR110 312 18.7 661 150 1.6 5 65 2380 - 241016601511
ZR145 391 23.5 829 200 2.1 6 66 2580 - 241016601511
ZR160 414 24.8 878 200 2.1 5 68 3680 3820 300019901631
ZR200 513 30.8 1088 250 2.5 5 68 3820 3820 300019901631
ZR250 619 37.1 1312 300 3.7 5 69 3920 3920 300019901631
ZR275 726 43.6 1539 350 3.7 6 69 4120 4200 300019901631
ZR300 755 45.3 1600 350 4.1 3 71 6200 6850 370024002120
ZR315VSD 815 48.9 1727 315 4.2 8 74 4750 - 380020601650
ZR315 850 51.0 1802 400 4.6 3 72 6200 6850 370024002120
ZR355 955 57.3 2024 450 5.1 4 72 6600 6700 370024002120
ZR400 1043 62.6 2211 500 5.6 4 72 6600 6850 370024002120
ZR450 1308 78.5 2773 600 7.82 2 74 - 8200 406024002120
ZR500 1538 92.3 3260 700 8.91 2 74 - 8400 406024002120
ZR630 1703102.2 3610 800 9.91 3 76 - 9125 406024002120
ZR750 1939116.4 4111 900 11.2 4 76 - 9125 406024002120
60hz-
60hz-10 bar(e)
ZR110 279 16.7 591 150 1.7 5 65 2380 - 241016601511
ZR145 328 19.7 695 200 2.0 6 66 2580 - 241016601511
ZR160 360 21.6 763 200 2.1 5 68 3680 3820 300019901631
ZR200 448 26.9 950 250 2.6 5 68 3820 3820 300019901631
ZR250 545 32.7 1155 300 3.1 5 69 3920 3920 300019901631
ZR275 650 39.0 1378 350 3.6 6 69 4120 4200 300019901631
ZR315VSD 746 44.7 1581 315 4.2 8 74 4750 - 380020601650
ZR300 677 40.6 1435 350 4.3 2 71 6200 6850 370024002120
ZR315 762 45.7 1615 400 4.6 3 72 6200 6850 370024002120
ZR355 858 51.5 1819 450 5.1 4 73 6600 6700 370024002120
ZR400 945 56.7 2003 500 5.5 4 73 6600 6850 370024002120
ZR450 1144 68.6 2425 600 7.74 2 74 - 8200 406024002120
http://www.atlascopco-yw.co.kr/ZT110.htm 05/04/2006
Untitled Document Page 2 of 2
(1)Reference conditions:
-Dry air
-Absolute inlet pressure 1 bar(a)
-Cooling and air in take temperature 20℃
-Nominal working pressure
Capacity of the compressor package measured according to ISO 1217,Third
-
Edition,Annex C
(2)Cooling water temp rise of 15℃
(3)±3 dB(A) according to Pneurop PN 8 NTC 2.2 test code measured at a distance of 1m
(4)ZR315VSD: capacity at 7 bar (e)
(5)ZR315VSD: capacity at 9bar (e)