TEST REPORT
IEC 60335-2-6
Safety of household and similar electrical appliances
Part 2: Particular requirements for stationary cooking ranges, hobs,
ovens and similar appliances
Report Reference No. ..................... : 247713
Date of issue ..................................... : 2013-12-09
Total number of pages ...................... : 118
Copyright © 2013 IEC System for Conformity Testing and Certification of Electrical Equipment
(IECEE), Geneva, Switzerland. All rights reserved.
This publication may be reproduced in whole or in part for non-commercial purposes as long as the IECEE is acknowledged as
copyright owner and source of the material. IECEE takes no responsibility for and will not assume liability for damages resulting from
the reader's interpretation of the reproduced material due to its placement and context.
If this Test Report Form is used by non-IECEE members, the IECEE/IEC logo and the reference to the CB Scheme
procedure shall be removed.
This report is not valid as a CB Test Report unless signed by an approved CB Testing Laboratory and appended
to a CB Test Certificate issued by an NCB in accordance with IECEE 02.
Test item description .................... : Hobs for building-in (Radiant hob elements)
Trade Mark ....................................... :
This Test Report, when bearing the Nemko name and logo is only valid when issued by a Nemko laboratory, or by a
laboratory having special agreement with Nemko.
Page 2 of 118 Report No:247713
Summary of testing:
This test report is upgrade of test report no. 226179 due to add-in alternative components and upgrade of
new edition test standard.
Tests performed (name of test and test clause): Testing location:
The tested samples are found to comply with the Nemko AS
requirements of the relevant product standards.
Gaustadalléen 30
The sample(s) tested complies with the N-0373 Oslo
requirements of standard which listed on first page Norway
and on summary of compliance with national
differences.
Marking label, user manual, packing text:
Instructions and marking shall be in a language
acceptable for the country where the equipment is
to be used.
Other product properties:
Depending on the country where the equipment is to
be used, national deviations may be considered.
Samples of the modified product may be tested
again according to relevant clauses of the product
standard, modified by national deviations.
The marking plates for the other models are the same as above label except the model name and rating.
Calibration All instruments used in the tests given in this test report are calibrated and
traceable to national or international standards.
Further information about traceability will be given on request.
Measurement Measurement uncertainties are calculated for all instruments and instrument
uncertainty set-ups given in this report. Calculations are based on the principles given in
the standard EA-4/02 (Dec. 1999), IEC Guide 115:2007 and other relevant
internal Nemko-procedures.
Further information about measurement uncertainties will be given on request.
Evaluation of results If not explicitly stated otherwise in the standard, the test is passed if the
measured value is equal to or below (above) the limit line, regardless of the
measurement uncertainty. If the measured value is above (below) the limit line,
the test is not passed - ref IEC Guide 115:2007. The instrumentation accuracy is
within limits agreed by IECEE-CTL.
Test item particulars .................................................. : Hobs for building-in (Radiant hob elements)
Classification of installation and use ...................... : Built-in appliance (Recessed), unattended use
Supply Connection .................................................... : Supply cord for permanent connection to fixed wiring;
type X attachment
...................................................................................... :
Possible test case verdicts:
- test case does not apply to the test object............ : N/A
- test object does meet the requirement .................. : P (Pass)
- test object does not meet the requirement ........... : F (Fail)
Testing .......................................................................... :
Date of receipt of test item ......................................... : 2013-10-16
Date (s) of performance of tests ............................... : 2013-10-16 to 2013-10-19
General remarks:
The test results presented in this report relate only to the object tested.
This report shall not be reproduced, except in full, without the written approval of the Issuing testing
laboratory.
"(see Enclosure #)" refers to additional information appended to the report.
"(see appended table)" refers to a table appended to the report.
When differences exist; they shall be identified in the General product information section.
Name and address of factory (ies) .......................... : Tecnowind S.p.A.
Via Piani Marischio, 19,
I – 60044 Fabriano (AN),
Italy
The report applies to built-in hobs of the TYPE: P58…… (3 or 4 hob elements) which has the
following electrical features:
- Power Input : From 5.1kW up to 6.9kW;
- Supply voltage : 220-240V 2/3 or 380-415V 2N/3N (with different connection)
- Frequency : 50/60Hz.
For appliances without electronic board, the temperature control is managed by thermostats
integrated in each heating element.
In appliances with electronic board the temperature control is managed by electronic regulator and
by thermostats integrated in each heating element.
The appliances are sold with supply cord (Type X attachment) and without plug. It is for permanent
connection to supply mains
The appliance fulfills the requirements of the relevant standards when installed as described in the
instruction manual (see also clause 7.12.4):
The appliance possible equipped with additional optional fixing device for supplement the fixing of heating
elements. See last 2 pages of photograph attachment for details.
Dimensions in mm. (alternative slim dimension for some models. see model list in General product
information and attachment - Comparison of normal dimension and slim dimension for details)
In order to identify elements, this scheme has to be considered when reading test results in the following
sections.
HOB HOB
No. 2 No. 3
HOB HOB
No. 1 No. 4
4 cooking positions
HOB
No. 2 HOB
No. 3
HOB
No. 1
3 cooking positions
IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict
6 CLASSIFICATION
6.1 Protection against electric shock: Class I P
Class I, II, III (IEC 60335-2-6 : 2002):
6.2 Protection against harmful ingress of water IPX0 N/A
IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict
11 HEATING
11.1 No excessive temperatures in normal use P
For cooking ranges and ovens, compliance is also N/A
checked by the test of 11.101 (IEC 60335-2-6:2002)
11.2 Placing and mounting of appliance as described P
- built-in (IEC 60335-2-6:2002) Acc. to installation instruction P
- against a wall (IEC 60335-2-6:2002) N/A
- on the floor (IEC 60335-2-6:2002) N/A
- fixed to the wall (IEC 60335-2-6:2002) N/A
- with or without the lid covering the hob surface N/A
(IEC 60335-2-6:2002)
- temperature sensing probes: any position likely to N/A
occur during normal use. (IEC 60335-2-6:2002)
IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict
Temperatures rises of the floor and floor of the test - other appliances, 70K P
corner, wooden cabinets and rectangular box not
exceeding specified values (IEC 60335-2-6:2002)
During the additional test for pyrolytic self-cleaning P
ovens, the temperature rise of the surface of knobs,
handles and levers shall not exceed specified values
(IEC 60335-2-6:2002)
Sealing compound does not flow out P
Protective devices do not operate, except P
components in protective electronic circuits tested for N/A
the number of cycles specified in 24.1.4
11.101 Cooking ranges and ovens placed as described N/A
(IEC 60335-2-6:2002)
Appliance operated under normal operation at rated N/A
voltage :
The appliance operated in specified conditions N/A
The appliance operated 60 min or N/A
until steady conditions are established N/A
Temperature rise of surfaces not exceed the values (see appended tables) N/A
specified in Table 102 (IEC 60335-2-6:2002)
IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict
14 TRANSIENT OVERVOLTAGES
Appliances withstand the transient overvoltages to N/A
which they may be subjected
Clearances having a value less than specified in table (see appended table) N/A
16 subjected to an impulse voltage test, the test
voltage specified in table 6
No flashover during the test, unless of functional N/A
insulation
In case of flashover of functional insulation, the N/A
appliance complies with clause 19 with the clearance
short circuited
15 MOISTURE RESISTANCE
15.1 Enclosure provides the degree of moisture protection N/A
according to classification of the appliance
Compliance checked as specified in 15.1.1, taking into N/A
account 15.1.2, followed by the electric strength test of
16.3
No trace of water on insulation which can result in a N/A
reduction of clearances and creepage distances below
values specified in clause 29
15.1.1 Appliances, other than IPX0, subjected to tests as N/A
specified in IEC 60529 ............................................. :
Water valves in external hoses for connection of an N/A
appliance to the water mains tested as specified for
IPX7 appliances
15.1.2 Hand-held appliance turned continuously through the N/A
most unfavourable positions during the test
Built-in appliances installed according to the N/A
instructions
Appliances placed or used on the floor or table placed N/A
on a horizontal unperforated support
Appliances normally fixed to a wall and appliances N/A
with pins for insertion into socket-outlets are mounted
on a wooden board
For IPX3 appliances, the base of wall mounted N/A
appliances is placed at the same level as the pivot
axis of the oscillating tube
IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict
19 ABNORMAL OPERATION
19.1 The risk of fire or mechanical damage under P
abnormal or careless operation obviated
Electronic circuits so designed and applied that a Only for models with E as the P
fault will not render the appliance unsafe first letter
Appliances incorporating heating elements P
subjected to the tests of 19.2 and 19.3, and
if the appliance also has a control that limit the P
temperature during clause 11 it is subjected to the
test of 19.4, and
if applicable, to the test of 19.5 N/A
Appliances incorporating PTC heating elements are N/A
also subjected to the test of 19.6
Appliances incorporating motors subjected to the N/A
tests of 19.7 to 19.10, as applicable
Appliances incorporating electronic circuits P
subjected to the tests of 19.11 and 19.12, as
applicable
Appliances incorporating contactors or relays P
subjected to the test of 19.14, being carried out
before the tests of 19.11
Appliances incorporating voltage selector switches N/A
subjected to the test of 19.15
IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict
2
19.3 Test of 19.2 repeated; test voltage (V): power input of P = 1,24 x Pn x (240/230) P
1.24 times rated power input.................................... see appended table
19.4 Test conditions as in cl. 11, any control limiting the P
temperature during tests of cl. 11 short-circuited
19.5 Test of 19.4 repeated on Class 0I and I appliances N/A
with tubular sheathed or embedded heating
elements. No short-circuiting, but one end of the
element connected to the elements sheath
The test repeated with reversed polarity and the other N/A
end of the heating element connected to the sheath
The test is not carried out on appliances intended to N/A
be permanently connected to fixed wiring and on
appliances where an all-pole disconnection occurs
during the test of 19.4
19.6 Appliances with PTC heating elements tested at N/A
rated voltage, establishing steady conditions
The working voltage of the PTC heating element is N/A
increased by 5% and the appliance is operated until
steady conditions are re-established. The voltage is
then increased in similar steps until 1.5 times working
voltage or until the PTC heating element ruptures
19.7 Stalling test by locking the rotor if the locked rotor N/A
torque is smaller than the full load torque or locking
moving parts of other appliances
Locked rotor, motor capacitors open-circuited or N/A
short-circuited, if required
Locked rotor, capacitors open-circuited one at a time N/A
Test repeated with capacitors short-circuited one at a N/A
time, unless
capacitor is of class P2 of IEC 60252-1 N/A
Appliances with timer or programmer supplied with N/A
rated voltage for each of the tests, for a period equal
to the maximum period allowed
Other appliances supplied with rated voltage for a N/A
period as specified
Winding temperatures not exceeding values (see appended table) N/A
specified in table 8
19.8 Three-phase motors operated at rated voltage with N/A
one phase disconnected
19.10 Series motor operated at 1.3 times rated voltage for N/A
1 min ......................................................................... :
During the test, parts not being ejected from the N/A
appliance
IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict
Insulation, other than of class III appliance, withstand the electric strength test of 16.3, -
the test voltage specified in table 4:
- basic insulation....................................................... : 1000V P
- supplementary insulation ....................................... : N/A
- reinforced insulation ............................................... : 3000V P
After operation or interruption of a control, clearances P
and creepage distances across the functional
insulation withstanding the electric strength test of
16.3. the test voltage being twice the working voltage
The appliance does not undergo a dangerous P
malfunction, and
no failure of protective electronic circuits, if the N/A
appliance is still operable
Appliances tested with an electronic switch in the off position, or in the stand-by mode: -
- do not become operational, or P
- if they become operational, do not result in a P
dangerous malfunction during or after the tests of
19.11.4
If the appliance contains lids or doors that are controlled by one or more interlocks, -
one of the interlocks may be released provided that:
- the lid or door does not move automatically to an N/A
open position when the interlock is released, and
- the appliance does not start after the cycle in N/A
which the interlock was released
Ovens: temperature in the centre of the oven not N/A
exceed 425C before opening (IEC 60335-2-
6:2002)
Temperature rise of the windings of induction hob N/A
elements and induction wok elements not exceed
the values specified in 19.7 (IEC 60335-2-6:2002)
Electric strength test of induction hob elements and N/A
induction wok elements is carried out immediately
after switching of the appliance (IEC 60335-2-
6:2002)
Glass in oven doors shall not be damaged N/A
(60335-2-6)
19.14 Appliances operated under the conditions of Clause Thermostats integrated in the P
11. Contactors or relays contacts operating under the heating elements operated
conditions of clause 11 short-circuited
19.15 For appliances with a mains voltage selector switch, N/A
the switch is set to the lowest rated voltage position
and the highest value of rated voltage is applied
IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict
20.102 For cooking ranges normally placed on the floor and with horizontally hinged oven -
doors with a hinge height of less than 430mm from the floor, the test of 20.101 is
repeated except that: (IEC 60335-2-6:2002)
-The cooking range is fitted with the stabilizing N/A
means, if any, specified in the instructions for
installation
-The mass of the load on the oven doors is N/A
increased to 50kg, or the mass of 22,5kg is placed
at the centre of the outer edge of the oven door,
whichever gives the most unfavourable results
The appliance shall not tilt N/A
Damage and deformation of doors are ignored
21 MECHANICAL STRENGTH
21.1 Appliance has adequate mechanical strength and is P
constructed as to withstand rough handling
Checked by applying blows to the appliance in P
accordance with test Ehb of IEC 60068-2-75, spring
hammer test, impact energy 0,5 J
If necessary, supplementary or reinforced insulation N/A
subjected to the electric strength test of 16.3
If necessary, repetition of groups of three blows on a N/A
new sample
Additional blows applied to the centre of glass doors N/A
(IEC 60335-2-6:2002)
The glass shall not fracture (IEC 60335-2-6:2002) N/A
Appliance incorporating visibly glowing heating elements enclosed in glass tubes, -
the blows are applied to the tubes as mounted in the appliance if they are : (IEC
60335-2-6:2002)
-located at the top of the oven and accessible to N/A
test probe 41 of IEC 61032
-located elsewhere in the oven and accessible to N/A
test probe B of IEC 61032
Hob surfaces of glass-ceramic or similar material: P
three blows applied on surfaces not exposed during
test of 21.102; impact energy 0,7 0,05 J
(IEC 60335-2-6:2002)
Temperature-sensing probe subjected to one cycle N/A
of test according to 15.101 and 16.2
(IEC 60335-2-6:2002)
21.2 Accessible parts of solid insulation having strength to Cover of supply terminal P
prevent penetration by sharp implements
The insulation is tested as specified, unless N/A
the thickness of supplementary insulation is at least 1 P
mm and reinforced insulation is at least 2 mm
IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict
22 CONSTRUCTION
22.1 Appliance marked with the first numeral of the IP N/A
system, relevant requirements of IEC 60529 are
fulfilled
22.2 Stationary appliance: means to provide all-pole disconnection from the supply -
provided, the following means being available:
- a supply cord fitted with a plug N/A
- a switch complying with 24.3 N/A
- a statement in the instruction sheet that a P
disconnection incorporated in the fixed wiring is to be
provided
- an appliance inlet N/A
Singe-pole switches and single-pole protective N/A
devices for the disconnection of heating elements in
single-phase, permanently connected class 01 and
class I appliances, connected to the phase conductor
22.3 Appliance provided with pins: no undue strain on N/A
socket-outlets
IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict
22.21 Wood, cotton, silk, ordinary paper and fibrous or Such material not used N/A
hygroscopic material not used as insulation, unless
impregnated
Magnesium oxide and mineral ceramic fibres are N/A
not considered as hygroscopic materials
(60335-2-6)
22.22 Appliances not containing asbestos P
22.23 Oils containing polychlorinated biphenyl (PCB) not P
used
22.24 Bare heating elements adequately supported P
In case of rupture, the heating conductor is unlikely to P
come in contact with accessible metal parts
22.25 Sagging heating conductors cannot come into contact N/A
with accessible metal parts
22.26 The insulation between parts operating at safety N/A
extra-low voltage and other live parts complies with
the requirements for double or reinforced insulation
22.27 Parts connected by protective impedance separated N/A
by double or reinforced insulation
22.28 Metal parts of Class II appliances conductively N/A
connected to gas pipes or in contact with water:
separated from live parts by double or reinforced
insulation
22.29 Class II appliances permanently connected to fixed N/A
wiring so constructed that the required degree of
access to live parts is maintained after installation
22.30 Parts serving as supplementary or reinforced P
insulation fixed so that they cannot be removed
without being seriously damaged, or
so constructed that they cannot be replaced in an N/A
incorrect position, and so that if they are omitted, the
appliance is rendered inoperable or manifestly
incomplete
22.31 Clearances and creepage distances over P
supplementary and reinforced insulation not reduced
below values specified in clause 29 as a result of
wear
Clearances and creepage distances between live P
parts and accessible parts not reduced below values
for supplementary insulation, if wires, screws etc.
become loose
22.32 Supplementary and reinforced insulation designed or P
protected against deposition of dirt or dust
IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict
23 INTERNAL WIRING
23.1 Wireways smooth and free from sharp edges P
Wires protected against contact with burrs, cooling P
fins etc.
Wire holes in metal well rounded or provided with P
bushings
Wiring effectively prevented from coming into contact N/A
with moving parts
23.2 Beads etc. on live wires cannot change their position, N/A
and are not resting on sharp edges or corners
Beads inside flexible metal conduits contained within N/A
an insulating sleeve
23.3 Electrical connections and internal conductors N/A
movable relatively to each other not exposed to
undue stress
Flexible metallic tubes not causing damage to N/A
insulation of conductors
Open-coil springs not used N/A
Adequate insulating lining provided inside a coiled N/A
spring, the turns of which touch one another
IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict
24 COMPONENTS
24.1 Components comply with safety requirements in P
relevant IEC standards
List of components (see appended table) P
IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict
24.101 Thermostat and energy regulators incorporating an For model type “R”, “M” only. P
off position shall not switch on a result of variations
in ambient temperatures (IEC 60335-2-6:2002)
During the test, the off position shall be maintained P
No breakdown shall occur; test voltage 500 V P
24.102 Incorporated socket-outlets in cooking ranges: N/A
single-phase type, earthing contact, rated current
16 A, protected by fuses or circuit breaker placed
behind a non-detachable cover rated current not
exceeding rated current of the socket-outlet
(IEC 60335-2-6:2002)
Cooking range for permanently connected to fixed N/A
wiring or is fitted with a polarized plug, the neutral
pole need not be protected (IEC 60335-2-6:2002)
If fuses become accessible after opening a drawer N/A
or other compartment, a non-detachable cover is
not required (IEC 60335-2-6:2002)
IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict
31 RESISTANCE TO RUSTING
IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict
A ANNEX A (INFORMATIVE)
ROUTINE TESTS
Description of routine tests to be carried out by the See CIG023 report P
manufacturer
B ANNEX B (NORMATIVE)
APPLIANCES POWERED BY RECHARGEABLE BATTERIES
The following modifications to this standard are N/A
applicable for appliances powered by batteries that
are recharged in the appliance
This annex does not apply to battery chargers N/A
3.1.9 Appliance operated under the following conditions: N/A
-the appliance, supplied by its fully charged battery, N/A
operated as specified in relevant part 2
-the battery is charged, the battery being initially N/A
discharged to such an extent that the appliance
cannot operate
-if possible, the appliance is supplied from the supply N/A
mains through its battery charger, the battery being
initially discharged to such an extent that the
appliance cannot operate. The appliance is operated
as specified in relevant part 2
If the appliance incorporates inductive coupling N/A
between two parts that are detachable from each
other, the appliance is supplied from the supply
mains with the detachable part removed
3.6.2 Part to be removed in order to discard the battery is N/A
not considered to be detachable
IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict
IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict
C ANNEX C (NORMATIVE)
AGEING TEST ON MOTORS
Tests, as described, carried out when doubt with N/A
regard to the temperature classification of the
insulation of a motor winding
D ANNEX D (NORMATIVE)
THERMAL MOTOR PROTECTORS
Applicable to appliances having motors that N/A
incorporate thermal motor protectors
E ANNEX E (NORMATIVE)
NEEDLE-FLAME TEST
Needle-flame test carried out in accordance with N/A
IEC 60695-11-5, with the following modifications:
7 Severities -
The duration of application of the test flame is N/A
30 s ± 1 s
9 Test procedure -
9.1 The specimen so arranged that the flame can be N/A
applied to a vertical or horizontal edge as shown in
the examples of figure 1
9.2 The first paragraph does not apply N/A
If possible, the flame is applied at least 10 mm from a N/A
corner
9.3 The test is carried out on one specimen N/A
If the specimen does not withstand the test, the test N/A
may be repeated on two additional specimens, both
withstanding the test
10 Evaluation of test results -
The duration of burning not exceeding 30 s N/A
However, for printed circuit boards, the duration of N/A
burning not exceeding 15 s
IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict
F ANNEX F (NORMATIVE)
CAPACITORS
Capacitors likely to be permanently subjected to the N/A
supply voltage, and used for radio interference
suppression or voltage dividing, comply with the
following clauses of IEC 60384-14, with the following
modifications:
1.5 Terminology -
1.5.3 Class X capacitors tested according to subclass X2 N/A
1.5.4 This subclause is applicable N/A
1.6 Marking -
Items a) and b) are applicable N/A
3.4 Approval testing -
3.4.3.2 Table II is applicable as described N/A
4.1 Visual examination and check of dimensions -
This subclause is applicable N/A
4.2 Electrical tests -
4.2.1 This subclause is applicable N/A
4.2.5 This subclause is applicable N/A
4.2.5.2 Only table IX is applicable N/A
Values for test A apply N/A
However, for capacitors in heating appliances the N/A
values for test B or C apply
4.12 Damp heat, steady state -
This subclause is applicable N/A
Only insulation resistance and voltage proof are N/A
checked
4.13 Impulse voltage -
This subclause is applicable N/A
4.14 Endurance -
Subclauses 4.14.1, 4.14.3, 4.14.4 and 4.14.7 N/A
applicable
4.14.7 Only insulation resistance and voltage proof are N/A
checked
Visual examination, no visible damage N/A
4.17 Passive flammability test -
IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict
G ANNEX G (NORMATIVE)
SAFETY ISOLATING TRANSFORMERS
The following modifications to this standard are N/A
applicable for safety isolating transformers:
7 Marking and instructions -
7.1 Transformers for specific use marked with: -
-name, trademark or identification mark of the N/A
manufacturer or responsible vendor
-model or type reference N/A
17 Overload protection of transformers and associated circuits -
Fail-safe transformers comply with subclause 15.5 of N/A
IEC 61558-1
22 Construction -
Subclauses 19.1 and 19.1.2 of IEC 61558-2-6 are N/A
applicable
29 Clearances, creepage distances and solid insulation -
29.1, 29.2 The distances specified in items 2a, 2c and 3 in table N/A
and 29.3 13 of IEC 61558-1 apply
H ANNEX H (NORMATIVE)
SWITCHES
Switches comply with the following clauses of IEC 61058-1, as modified: -
-The tests of IEC 61058-1 carried out under the N/A
conditions occurring in the appliance
-Before being tested, switches are operated 20 times N/A
without load
8 Marking and documentation -
Switches are not required to be marked N/A
However, switches that can be tested separately N/A
from the appliance marked with the manufacturer’s
name or trade mark and the type reference
13 Mechanism -
The tests may be carried out on a separate sample N/A
15 Insulation resistance and dielectric strength -
IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict
I ANNEX I (NORMATIVE)
MOTORS HAVING BASIC INSULATION THAT IS INADEQUATE FOR THE RATED
VOLTAGE OF THE APPLIANCE
The following modifications to this standard are N/A
applicable for motors having basic insulation that is
inadequate for the rated voltage of the appliance:
8 Protection against access to live parts -
8.1 Metal parts of the motor are considered to be bare N/A
live parts
11 Heating -
11.3 Temperature rise of the body of the motor is N/A
determined instead of the temperature rise of the
windings
IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict
J ANNEX J (NORMATIVE)
COATED PRINTED CIRCUIT BOARDS
Testing of protective coatings of printed circuit boards N/A
carried out in accordance with IEC 60664-3 with the
following modifications:
5.7 Conditioning of the test specimens -
When production samples are used, three samples N/A
of the printed circuit board are tested
5.7.1 Cold -
The test is carried out at -25C N/A
5.7.3 Rapid change of temperature -
Severity 1 is specified N/A
5.9 Additional tests -
This subclause is not applicable N/A
IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict
K ANNEX K (NORMATIVE)
OVERVOLTAGE CATEGORIES
The information on overvoltage categories is P
extracted from IEC 60664-1
Overvoltage category is a numeral defining a P
transient overvoltage condition
Equipment of overvoltage category IV is for use at N/A
the origin of the installation
Equipment of overvoltage category III is equipment in N/A
fixed installations and for cases where the reliability
and the availability of the equipment is subject to
special requirements
Equipment of overvoltage category II is energy P
consuming equipment to be supplied from the fixed
installation
If such equipment is subjected to special N/A
requirements with regard to reliability and availability,
overvoltage category III applies
Equipment of overvoltage category I is equipment for N/A
connection to circuits in which measures are taken to
limit transient overvoltages to an appropriate low level
L ANNEX L (INFORMATIVE)
GUIDANCE FOR THE MEASUREMENT OF CLEARANCES AND CREEPAGE
DISTANCES
Sequences for the determination of clearances and P
creepage distances
M ANNEX M (NORMATIVE)
POLLUTION DEGREE
The information on pollution degrees is extracted P
from IEC 60664-1
Pollution -
The microenvironment determines the effect of P
pollution on the insulation, taking into account the
macroenvironment
Means may be provided to reduce pollution at the P
insulation by effective enclosures or similar
Minimum clearances specified where pollution may P
be present in the microenvironment
Degrees of pollution in the microenvironment -
IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict
N ANNEX N (NORMATIVE)
PROOF TRACKING TEST
The proof tracking test is carried out in accordance N/A
with IEC 60112 with the following modifications:
7 Test apparatus -
7.3 Test solutions -
Test solution A is used N/A
10 Determination of proof tracking index (PTI) -
10.1 Procedure -
The proof voltage is 100V, 250V, 175V, 400V or N/A
600V ......................................................................... :
The last paragraph of Clause 3 applies N/A
The test is carried out on five specimens N/A
In case of doubt, additional test with proof voltage N/A
reduced by 25V, the number of drops increased to
100
10.2 Report -
The report stating if the PTI value was based on a N/A
test using 100 drops with a test voltage of (PTI-25) V
O ANNEX O (INFORMATIVE)
SELECTION AND SEQUENCE OF THE TESTS OF CLAUSE 30
Description of tests for determination of resistance to N/A
heat and fire
IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict
P ANNEX P (INFORMATIVE)
GUIDANCE FOR THE APPLICATION OF THIS STANDARD TO APPLIANCES
USED IN WARM DAMP EQUABLE CLIMATES
Modifications applicable for class 0 and 01 appliances having a rated voltage -
exceeding 150V, intended to be used in countries having a warm damp equable
climate and that are marked WDaE
Modifications may also be applied to class 1 appliances having a rated voltage -
exceeding 150V, intended to be used in countries having a warm damp equable
climate and that are marked WdaE, if liable to be connected to a supply mains that
excludes the protective earthing conductor
5 General conditions for the tests -
5.7 The ambient temperature for the tests of Clauses 11 N/A
+3
and 13 is 40 /0
7 Marking and instructions -
7.1 The appliance marked with the letters WDaE N/A
7.12 The instructions state that the appliance is to be N/A
supplied through a RCD having a rated residual
operating current not exceeding 30 mA
The instructions state that the appliance is N/A
considered to be suitable for use in countries having
a warm damp equable climate, but may also be used
in other countries
11 Heating -
11.8 The values of Table 3 are reduced by 15 K N/A
13 Leakage current and electric strength at operating temperature -
13.2 The leakage current for class I appliances not N/A
exceeding 0,5 mA
15 Moisture resistance -
15.3 The value of t is 37 C N/A
16 Leakage current and electric strength -
16.2 The leakage current for class I appliances not N/A
exceeding 0,5 mA
19 Abnormal operation -
19.13 The leakage current test of 16.2 is applied in addition N/A
to the electric strength test of 16.3
Q ANNEX Q (INFORMATIVE)
SEQUENCE OF TESTS FOR THE EVALUATION OF ELECTRONIC CIRCUITS
Description of tests for appliances incorporating electronic circuits -
IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict
R ANNEX R (NORMATIVE)
SOFTWARE EVALUATION
Software evaluated in accordance with the following clauses of Annex H of IEC 60730- -
1, as modified
H.2 Definitions -
Only definitions H.2.16 to H.2.20 applicable N/A
H.7 Information -
Only footnotes 12) to 18) of Table 7.2, as modified, N/A
applicable
H.11.12 Controls using software -
All the subclauses of H.11.12, as modified, except N/A
H.11.12.6 and H.11.12.6.1, applicable
H.11.12.7 Delete text N/A
H.11.12.7.1 For appliances using software class C having a N/A
single channel with self-test and monitoring structure,
the manufacturer provides the measures necessary
to address the fault/errors in safety related segments
and data
H.11.12.8 Software fault/error detection occurs before N/A
compliance with 19.13 of IEC 60335-1 is impaired
H.11.12.8.1 Replace text N/A
H.11.12.13 Software and safety related hardware under its N/A
control initializes and terminates before compliance
with 19.13 of IEC 60335-1 is impaired
IEC 60335-2-6
IEC 60335-2-6
IEC 60335-2-6
IEC 60335-2-6
IEC 60335-2-6
IEC 60335-2-6
IEC 60335-2-6
IEC 60335-2-6
IEC 60335-2-6
IEC 60335-2-6
IEC 60335-2-6
IEC 60335-2-6
(13.) TYPE P58…… MODEL EC5500 with new PCB control unit and new heating element
PCB control unit: EIKA _ BG341336011109
Heating element: EGO _ 10.53211.004 / EIKA _ 2502333912
Test voltage (V) .................................................... : 257V (6,89kW)
Ambient (C) ......................................................... : 23,5
Thermocouple locations dT (K) Max. dT (K)
EGO / EIKA
Supply cord (T90) 39 / 39 65
X2 capacitor (T110) 36 / 37 85
Transformer 38 / 39 65
Relay (LNH33012) 48 / 50 65
PCB 36 / 38 120
Internal wire 100 / 116 175
Test corner, under side place 18 / 17 65
Bottom metal plate 53 / 53 Ref. only
IEC 60335-2-6
(14.) TYPE P58…… MODEL EO6900 with new PCB control unit and new heating element
PCB control unit: EIKA _ BH3715360111xx
Heating element: EGO _ 10.51311.xxx / EIKA _ 2302734932
Test voltage (V) .................................................... : 261V (8,64kW)
Ambient (C) ......................................................... : 19
Thermocouple locations dT (K) Max. dT (K)
Supply cord (T90) 63 65
Rast T. Block (T125) 79 100
Thermostat (T250) 123 225
Internal wirings (T200) 109 175
Faston cover (Relay R1) 58 Cfr. Cl.30
Coil relay R1 (cl.155/F) 65 115
Transformer (SMPS, T1) 51 65
PCB 58 120
X2 capacitor (T110) 53 85
Plastic conduit 93 Cfr. Cl.30
Touch control zone 30 45
Wood in general 53 70
(15.) TYPE P58…… MODEL EC6700 with new alt. heating element and slim dimension
PCB control unit: EIKA _ BH3715360111xx
Heating element: EGO _ 10.57413.624
Test voltage (V) .................................................... : 262V (8,4kW)
Ambient (C) ......................................................... : 20
Thermocouple locations dT (K) Max. dT (K)
Supply cord (T90) 53 65
Rast T. Block (T125) 80 100
Internal wirings (T200) 124 175
Wooden frame back 57 70
Wooden frame side 47 70
IEC 60335-2-6
(17.) TYPE P58…… MODEL EO6400 with PCB control unit: EIKA _ BN34D36211107
IEC 60335-2-6
IEC 60335-2-6
IEC 60335-2-6
11.101 TABLE: Temperature rise limits for accessible surfaces specifications N/A
test step n°/ function temperature duration
11.101 TABLE: Temperature rise limits for accessible front and side surfaces N/A
dT (K) Max. dT (K)
Front surfaces of oven doors
Test step n.
Ambient (°C)
Metal and painted metal 45
Vitreous-enamelled metal 50
Glass and ceramic 60
Plastic having a thickness exceeding 0,3mm 80
Other accessible front and side surfaces
(or surfaces above 850 mm)
Test step n.
Ambient (°C)
Metal and painted metal 60
Vitreous-enamelled metal 65
Glass and ceramic 80
Plastic having a thickness exceeding 0,3mm 100
IEC 60335-2-6
IEC 60335-2-6
IEC 60335-2-6
Relay, JS1a-B-6V-H150
Winding (t1=22.5 t2=24.5) 96.6 131.7 91 116 150
Relay, LNH30012
Winding (t1=25 t2=23.5) 340 428 69 93 150
Transformer FLG30
Primary 1 (t1=22,0, t2=22,5) 310,8 424,4 93 116 190
Primary 2 (t1=22,0, t2=22,5) 308,0 422,3 95 117 190
Secondary (t1=22,0, t2=22,5) 5,73 7,75 90 112 190
Transformer TRP 01
Primary (t1=23,0, t2=23,0) 714,3 1084,5 133 156 175
Secondary (t1=23,0, t2=23,0) 7,42 10,14 94 117 175
Transformer BV 030-…
Primary 1 (t1=22,0, t2=21,0) 354,6 472,5 86 107 175
IEC 60335-2-6
Transformer EI42/14,5
Primary (t1=20,5, t2=22,0) 790,1 1013,8 71 93 175
Secondary (t1=20,5, t2=22,0) 2,015 2,602 73 95 175
Transformer ZAREL
Code: 003179675 00321004
Class F
(On EIKA Electronic board)
(at 267V)
Primary (t1=23.5 t2=23.5) 830 1340 159 183 190
Secondary (t1=23.5 t2=23.5) 3.690 5.660 153 177 190
Transformer KASCHKE
Code: 451 761
(supposed as class A)
(On DIEHL Electronic board)
(at 267V)
Primary (t1=23.5 t2=23.5) 3.963 5.48 99 123 150
Secondary (t1=23.5 t2=23.5) 0.101 0.137 96 120 150
IEC 60335-2-6
IEC 60335-2-6
IEC 60335-2-6
IEC 60335-2-6
IEC 60335-2-6
IEC 60335-2-6
For Model E….. / R….. / Model M….. (Except for Models EO5100, EO5200, EO5300 and EO5410)
Heating element EGO 10.57411.xxx 1800/1000W IECEN 60335-1 VDE Tested
back left (a) 230V IECEN 60335-2-6 in the
145/250mm HL appliance
type
Alt. Ceramaspeed 165V8L6831D 1800/1000W IECEN 60335-1 VDE Tested
230V IECEN 60335-2-6 in the
145/250mm HL appliance
type
Alt. EIKA 2702433832 1800/1000W IECEN 60335-1 VDE Tested
230V IECEN 60335-2-6 in the
145/250mm HL appliance
type
Alt. EGO 10.57411.xxx 1800/1000W 230V IECEN 60335-1 VDE Tested
145/250mm HL IECEN 60335-2-6 in the
type appliance
For Model RE…. / RB….
Heating element Ceramaspeed 190V8L6696D 2200/1400W 230V IECEN 60335-1 VDE Tested
back left (a) 170/265mm HL IECEN 60335-2-6 in appliance
type
Alt. Ceramaspeed 190V8L6696D 2200/1400W 230V IECEN 60335-1 VDE Tested
170/265mm HL IECEN 60335-2-6 in appliance
type
Alt. EIKA 2852433832 2200/1400W 230V IECEN 60335-1 VDE Tested
170/265mm HL IECEN 60335-2-6 in appliance
type
Alt. EGO 10.57413.xxx 2200/1400W 230V IECEN 60335-1 VDE Tested
IECEN 60335-2-6 in appliance
For Model EO5100, EO5200, EO5300 and EO5410
Alt. Heating Ceramaspeed 300T8L8343D 2400/1500W IECEN 60335-1 VDE Tested
element back 230V IECEN 60335-2-6 in the
left (a) 275/210mm HL appliance
type
For Model EO6400, EO6900
Heating element 10.51311.xxx EGO 230V 50/60Hz IEC/EN 60335-1 VDE
front left 2300/1600/800W IEC/EN 60335-2-6 Tested in
appliance
Alt. Heating 2302734932 Eika 230V 50/60Hz IEC/EN 60335-1 VDE
element front 23001600/800W IEC/EN 60335-2-6 Tested in
left (a) appliance
For Model E….. / R….. / M….. / C…..
1))
Thermostat for Electrovac Z98 12°/250V 8°/400V IECEN 60730-1 VDE
heating T250 IECEN 60730-2-1
elements IECEN 60730-2-9
1))
Thermostat for EGO 60.25171.003 12° 250V 8° 400V IECEN 60730-1 VDE
heating T250 IECEN 60730-2-1
elements (a) IECEN 60730-2-9
IEC 60335-2-6
1)
Thermostat for Electrovac Z82 12°/250V 7°/400V IECEN 60730-1 VDE
heating T250 IECEN 60730-2-1
elements (a) IECEN 60730-2-9
1)
Thermostat for Electrovac Z95 12° 250V 8° 400V IECEN 60730-1 VDE
heating T250 IECEN 60730-2-1
elements (a) IECEN 60730-2-9
1)
Thermostat for EIKA TH0xxxxx 12° 250V 8° 400V IECEN 60730-1 VDE
heating T250 IECEN 60730-2-1
elements (a) IECEN 60730-2-9
Thermostat for Electrovac Z15 12° 250V 8° 400V IECEN 60730-1 ENEC 10,
1)
heating T250 IECEN 60730-2-1 VDE
elements (a) IECEN 60730-2-9
Thermostat for Electrovac Z16 12° 250V 8° 400V IECEN 60730-1 Tested with
heating T250 IECEN 60730-2-1 component
elements (a) IECEN 60730-2-9 standard
Test report
CTI-CB 598-
1 by CTI-
Vienna
For Model R….. / M…..
1)
Energy Siebe Appliance MSA V03 15A 240V T125 IECEN 60730-1 BEAB ,
)
regulators, Controls IECEN 60730-2- VDE
single zone (Invensys) 11
1)
Energy Siebe Appliance MSA V01 15A 240V T125 IECEN 60730-1 BEAB ,
1)
regulators (a) Controls IECEN 60730-2- KEMA
(Invensys) 11
13A 230V freq.
1)
Energy EGO 50.57021.010 IECEN 60730-1 VDE , N, S,
regulators (a) Op. T125 IECEN 60730-2- D, FI, IMQ,
(the component 11 KEMA, ÖVE
has been
separately tested
for 240/400V
13A 230V T125
1)
Energy EGO 50.55021.100 IECEN 60730-1 VDE , N, S,
regulators (a) (the component IECEN 60730-2- D, FI, IMQ,
has been 11 KEMA, ÖVE
separately tested
for 240/400V
Energy EGO 50.75021.000 230V 13A T125 IECEN 60730-1 VDE
regulators (a) IECEN 60730-2-
11
Energy EGO 50.77021.000 230V 13A T125 IECEN 60730-1 VDE
regulators (a) IECEN 60730-2-
11
13A 230V T125
1)
Energy EGO 50.57071.041 IECEN 60730-1 VDE , N, S,
regulators (a) (the component IECEN 60730-2- D, FI, IMQ,
has been 11 KEMA, ÖVE
separately tested
for 240/400V
IEC 60335-2-6
IEC 60335-2-6
IEC 60335-2-6
IEC 60335-2-6
IECEN 60255-1 1)
Relay (a) Schrack RFH34006 16A 250V 6Vdc VDE
(considered as IECEN 60255-2- Tested in
class A) 23 the
IECEN 60335-1 appliance
IECEN 60335-2-6
Relay (a) Finder 45.71.7.006.0 16A 250V IECEN 60255-1 IMQ, VDE
310 (considered as IECEN 60255-2- Tested in
class 105 A) 23 the
IECEN 60335-1 appliance
IECEN 60335-2-6
1)
Relay (a) Schrack RTH34012 18A 250V Cl.F IECEN 60255-1 VDE
IECEN 60255-2- Tested in
23 appliance
IECEN 60335-1
IECEN 60335-2-6
1)
Relay (a) Tyco T 7S V1H6- 6A 250V Cl.F IECEN 60255-1 VDE
12-WG IECEN 60255-2- Tested in
23 appliance
IECEN 60335-1
IECEN 60335-2-6
1)
Relay (a) Hongfa HF152F-T- 10A 250V Cl.F IECEN 60255-1 VDE
012-1HT 12V IECEN 60255-2- Tested in
23 appliance
IECEN 60335-1
IECEN 60335-2-6
1)
Relay (a) Hongfa HF152F-T- 16A 250V Cl.F IECEN 60255-1 VDE
012-1HTQ 12V IECEN 60255-2- Tested in
23 appliance
IECEN 60335-1
IECEN 60335-2-6
1)
Relay (a) Hongfa HF3FA 6A 250V Cl.F IECEN 60255-1 VDE
IECEN 60255-2- Tested in
23 appliance
IECEN 60335-1
IECEN 60335-2-6
1)
Relay (a) Hongfa HF115F-Q 18A 250V Cl.F IECEN 60255-1 VDE
IECEN 60255-2- Tested in
23 appliance
IECEN 60335-1
IECEN 60335-2-6
1)
Relay (a) Hongfa 881WP2-1AC- 17A 250V Cl.F IECEN 60255-1 VDE
F-C IECEN 60255-2- Tested in
23 appliance
IECEN 60335-1
IECEN 60335-2-6
1)
Relay (a) Matsushita JS1aP.../T 10A 250V Cl.F IECEN 60255-1 VDE
IECEN 60255-2- Tested in
23 appliance
IECEN 60335-1
IECEN 60335-2-6
IEC 60335-2-6
1)
Relay (a) Song Chuan 812HT-1A-C 10A 250V Cl.F IECEN 60255-1 VDE
E F12V IECEN 60255-2- Tested in
23 appliance
IECEN 60335-1
IECEN 60335-2-6
1)
Relay (a) Song Chuan 899-1CH-F-C 10A 250V Cl.F IECEN 60255-1 VDE
IECEN 60255-2- Tested in
23 appliance
IECEN 60335-1
IECEN 60335-2-6
1)
Relay (a) Song Chuan SG7 100 E12 16A 250V Cl.F IECEN 60255-1 VDE
IECEN 60255-2- Tested in
23 appliance
IECEN 60335-1
IECEN 60335-2-6
Capacitors
1)
Capacitor VISHAY WKO 4,7nF 250V Y2 IEC 60384-14 FI , tested
440V X1, T85 IECEN 60335-1 in the
IECEN 60335-2-6 appliance
1) 1)
Capacitor Murata DE2E3KH472 3300pF 250V IEC 60384-14 N ,S ,
1) 1)
M IECEN 60335-1 S+ , VDE ,
1) 1)
IECEN 60335-2-6 FI , D ,
tested in the
appliance
1) 1)
Capacitor (a) Murata KH332H 3300pF 250V IEC 60384-14 N ,S ,
1) 1)
X1/Y2 IECEN 60335-1 S+ , VDE ,
1) 1)
IECEN 60335-2-6 FI , D ,
tested in the
appliance
1) 1)
Capacitor Philips 336 2 MKP 0,1µF 275V X2 IEC 60384-14 N , FI ,
T100 IECEN 60335-1 tested in the
IECEN 60335-2-6 appliance
1)
Capacitor (a) Arcotronics 1.40.00 MKT 0,1µF 275V X2 IEC 60384-14 N , tested in
T100 IECEN 60335-1 the
IECEN 60335-2-6 appliance
Capacitor (a) VISHAY 33H2 R0637 0.1µF IEC 60384-14 CEBEC
275Vac T110
Capacitor (a) Arcotronics R.46 MKP X2 0.1µF IEC 60384-14 ENEC03,
SH 275Vac T110 IMQ
Capacitor (a) BC 22221166116 100nF 275V T105 IEC 60384-14 D
1109 MKP
338 2
X capacitor ARCOTRONIC Series R46 100nF X2 110°C IEC 60384-14 ENEC-IMQ
Alt. Vishay Röderstein Series F1710 100nF X1 110°C IEC 60384-14 VDE
Alt. Vishay BC- Series E12 100nF X2 110°C IEC 60384-14 ENEC-SGS
Components MKP339
Alt. Vishay BC- Series E12 100nF X2 125°C IEC 60384-14 ENEC-SGS
Components MKP339T
Y capacitor Vishay Draloric Serie WYO 4n7F Y2 125°C IEC 60384-14 VDE
IEC 60335-2-6
IEC 60335-2-6
IEC 60335-2-6
IEC 60335-2-6
Object/ Manufacturer/ Type/ Ball pressure test Glow wire test Glow-wire Glow- wire Needle Verdict
part No. trademark model °C (GWT) flammability index ignition - flame
°C (GWFI) temp. test
°C (GWIT) (NFT)
°C
75 125 cl. 11 cl. 19 550 650 750 850 550 650 750 850 675 775
+40 +25
te ti te ti
Plastic cover 75 x P
to terminals
Supply screw 125 0 0 x P
terminal
Cover of 75 x P
screw
terminal
DDS electronic board DDS218 and DDS151REL
Transformer 125 0 0 x P
IEC 60335-2-6
Object/ Manufacturer/ Type/ Ball pressure test Glow wire test Glow-wire Glow- wire Needle Verdict
part No. trademark model °C (GWT) flammability index ignition - flame
°C (GWFI) temp. test
°C (GWIT) (NFT)
°C
75 125 cl. 11 cl. 19 550 650 750 850 550 650 750 850 675 775
+40 +25
te ti te ti
Relay 125 0 0 x P
PCB 125 0 0 x x P
EIKA electronic board 8A 1..0 360….. or 8B.1..0 360….. or BJ(K)3..A36...1.. and DIEHL electronic board TC-4SE-Z-XX-YY-105-U230
PCB 125 0 0 x x P
Zarel 125 0 0 x P
transformer
cover
X2 capacitor 125 0 0 x P
PCB 105 0 0 x x P
IEC 60335-2-6
Object/ Manufacturer/ Type/ Ball pressure test Glow wire test Glow-wire Glow- wire Needle Verdict
part No. trademark model °C (GWT) flammability index ignition - flame
°C (GWFI) temp. test
°C (GWIT) (NFT)
°C
75 125 cl. 11 cl. 19 550 650 750 850 550 650 750 850 675 775
+40 +25
te ti te ti
Relay 125 0 0 x P
FINDER
X2 capacitor 125 0 0 x P
PCB 125 0 0 x x P
Transformer 125 0 0 x P
(plastic part)
Coil frame 125 0 0 x P
PCB 125 0 0 x x P
IEC 60335-2-6
Object/ Manufacturer/ Type/ Ball pressure test Glow wire test Glow-wire Glow- wire Needle Verdict
part No. trademark model °C (GWT) flammability index ignition - flame
°C (GWFI) temp. test
°C (GWIT) (NFT)
°C
75 125 cl. 11 cl. 19 550 650 750 850 550 650 750 850 675 775
+40 +25
te ti te ti
PCB 125 0 0 x x P
transformer 125 0 0 x P
bobbin
X2 capacitor 125 0 0 x P
IEC 60335-2-6
Object/ Manufacturer/ Type/ Ball pressure test Glow wire test Glow-wire Glow- wire Needle Verdict
part No. trademark model °C (GWT) flammability index ignition - flame
°C (GWFI) temp. test
°C (GWIT) (NFT)
°C
75 125 cl. 11 cl. 19 550 650 750 850 550 650 750 850 675 775
+40 +25
te ti te ti
Eika BN340D3621110x
PCB 125 0 0 X x P
IEC60335_2_6J - ATTACHMENT
Clause Requirement – Test Result – Remark Verdict
IEC60335_2_6J - ATTACHMENT
Clause Requirement – Test Result – Remark Verdict
IEC60335_2_6J - ATTACHMENT
Clause Requirement – Test Result – Remark Verdict
IEC60335_2_6J - ATTACHMENT
Clause Requirement – Test Result – Remark Verdict
IEC60335_2_6J - ATTACHMENT
Clause Requirement – Test Result – Remark Verdict
7.12.Z101 Add the following new subclause before 7.12.1: The Corrigendum to EN 60335-2- P
specific instructions related to the safe operation of 6:2003/A11:2010, June 2012,
this appliance (as given in 7.12 of this standard) had changed “4 mm” to “at
shall be collated together in the front section of the least 3 mm”.
user instructions. The height of the characters,
measured on the capital letters, shall be at least 4
mm. (EN 60335-2-6)
These instructions shall also be available in an P
alternative format, e.g. on a website.
7.12.Z1 The specific instructions related to the safe P
operation of this appliance is collated together in the
front section of the user instructions
The height of the characters, measured on the P
capital letters, is at least 3 mm
These instructions are also available in an P
alternative format, e.g. on a website
7.14 The height of the triangle used with symbol IEC N/A
60417-5041 shall be at least 12 mm.
(EN 60335-2-6)
8.1.1 Also test probe 18 of EN 61032 is applied P
The appliance being in every possible position P
during the test
The force on the probe in the straight position is P
increased to 10 N when probe 18 is used
When using test probe 18 the appliance is fully P
assembled as in normal use without any parts
removed, and
parts intended to be removed for user maintenance P
are also not removed
Use of test probe B and probe 18 of IEC 61032: no P
contact with live parts (EN 60335-2-6)
8.2 Compliance is checked by applying the test probes P
of EN 61032
For built-in appliances and fixed appliances, the test P
probe B and probe 18 of EN 61032 are applied only
after installation
11.8 Footnotes to “External enclosure of motor-operated N/A
appliances” to be taken into account
11.101 Temperature rise of surfaces not exceed the values See appended table N/A
specified in Table 102 (EN 60335-2-6)
15.1.2 Appliances with an automatic cord reel tested with N/A
the cord in the most unfavourable position so that
the reeling of the wet cord may affect electrical
insulation during operation, the cord not being dried
before reeling
19.102 Thermal control by NTC: replace by resistor with N/A
middle of the range value (EN 60335-2-6)
Page 6 of 16 Report No:247713
IEC60335_2_6J - ATTACHMENT
Clause Requirement – Test Result – Remark Verdict
20.2 When using the test probe similar to test probe B N/A
with a circular stop face, the accessories and
detachable covers are removed
Test probe 18 applied with a force of 2,5N on the N/A
appliance fully assembled
Appliances are fully assembled as in normal N/A
operation without any parts removed.
(EN 60335-2-6)
20.101 Stability test with the oven in its intended position N/A
following manufacturer's instructions
(EN 60335-2-6)
20.Z101 Horizontally hinged oven doors of floor standing N/A
cooking ranges, when fully opened, shall not cause
a hazard. (EN 60335-2-6)
21.101 Inclination difference between empty inside and N/A
loaded in rest position shall not exceed 6°
(EN 60335-2-6)
21.102 In the third paragraph of the test specification, P
replace “The vessel” by “For hob elements, other
than induction wok elements, the vessel”.
(EN 60335-2-6)
22.12 Handles, knobs etc. fixed in a reliable manner so that P
they will not work loose in normal use if loosening
could result in a hazard (including ingestion or a
choking hazard for vulnerable people”. (EN 60335-2-
6)
22.122 Ovens with shelves that can be withdrawn shall be N/A
fitted with rest or stop positions
(EN 60335-2-6)
This requirement does not apply to shelves that are N/A
designed to contain liquids, such as roasting trays
and the like. (EN 60335-2-6)
24.1 Components comply with the safety requirements P
specified in the relevant standards as far as they
reasonably apply
The requirements of Clause 29 of this standard P
apply between live parts of components and
accessible parts of the appliance.
The requirements of 30.2 of this standard apply to P
parts of non-metallic material in components
including parts of non-metallic material supporting
current-carrying connections inside components
Components that have not been previously tested or P
do not comply with the standard for the relevant
component are tested according to the requirements
of 30.2
Page 7 of 16 Report No:247713
IEC60335_2_6J - ATTACHMENT
Clause Requirement – Test Result – Remark Verdict
Components that have been previously tested and shown to comply with the -
resistance to fire requirements in the standard for the relevant component need not
be retested provided that:
- the severity specified in the component standard is P
not less than the severity specified in 30.2, and
- the test report for the component states whether it P
complied with the standard for the relevant
component with or without flame, flames not
exceeding 2 s during the test are ignored
Unless components have been previously tested N/A
and found to comply with the relevant standard for
the number of cycles specified, they are tested in
accordance with 24.1.1 to 24.1.9
For components mentioned in 24.1.1 to 24.1.9, no N/A
additional tests specified in the relevant standard for
the component are necessary other than those
specified in 24.1.1 to 24.1.9
Components that have not been separately tested P
and found to comply with the relevant standard, and
components that are not marked or not used in P
accordance with their marking,
are tested in accordance with the conditions P
occurring in the appliance, the number of samples
being that required by the relevant standard
Lamp holders and starter holders that have not been N/A
previously tested and found to comply with the
relevant standard are tested as a part of the
appliance and additionally comply with the gauging
and interchangeability requirements of the relevant
standard under the conditions occurring in the
appliance
Where the relevant standard specifies these N/A
gauging and interchangeability requirements at
elevated temperatures, the temperatures measured
during the tests of Clause 11 are used
Plugs and socket-outlets and other connecting N/A
devices of interconnection cords are not
interchangeable with plugs and socket-outlets listed
in IEC/TR 60083 or IEC 60906-1, or
with connectors and appliance inlets complying with N/A
the standard sheets of IEC 60320-1,
if direct supply to these parts from the supply mains N/A
gives rise to a hazard
24.1.7 If the remote operation of the appliance is via a N/A
telecommunication network, the relevant standard
for the telecommunication interface circuitry in the
appliance is EN 41003
Page 8 of 16 Report No:247713
IEC60335_2_6J - ATTACHMENT
Clause Requirement – Test Result – Remark Verdict
IEC60335_2_6J - ATTACHMENT
Clause Requirement – Test Result – Remark Verdict
ZA ANNEX ZA (NORMATIVE)
SPECIAL NATIONAL CONDITIONS
Norway
19.5 The test is also applicable to appliances intended to N/A
be permanently connected to fixed wiring
Norway
22.2 The second paragraph of this subclause, dealing N/A
with single-phase, permanently connected class I
appliances having heating elements, is not
applicable due to the supply system
ZB ANNEX ZB (INFORMATIVE)
A-DEVIATIONS
Ireland
25.6 These regulations apply to all plugs for domestic use To be checked before -
at a voltage of not less than 200 V and in general marketing in this country
allow only plugs complying with I.S. 401:1997, or
equivalent, to be fitted to domestic appliances
Page 10 of 16 Report No:247713
IEC60335_2_6J - ATTACHMENT
Clause Requirement – Test Result – Remark Verdict
United Kingdom
25.6 These regulations apply to all plugs for domestic use To be checked before -
at a voltage of not less than 200 V and in general marketing in this country
allow only plugs to BS 1363 to be fitted to domestic
appliances. It also allows plugs to BS 4573 and EN
50075 to be fitted to shavers and toothbrushes
ZC ANNEX ZC (NORMATIVE)
NORMATIVE REFERENCES TO INTERNATIONAL PUBLICATIONS WITH THEIR
CORRESPONDING EUROPEAN PUBLICATIONS
A list of referenced documents in this standard P
ZD ANNEX ZD (INFORMATIVE)
IEC and CENELEC CODE DESIGNATIONS FOR FLEXIBLE CORDS
A table with IEC and CENELEC code designations P
for flexible cords
ZE ANNEX ZE (INFORMATIVE)
SPECIFIC ADDITIONAL REQUIREMENTS FOR APPLIANCES AND MACHINES
INTENDED FOR COMMERCIAL USE
7.1 Business name and full address of the manufacturer N/A
and, where applicable, his authorized
representative........................................................ :
Model or type reference ........................................ : N/A
IEC60335_2_6J - ATTACHMENT
Clause Requirement – Test Result – Remark Verdict
IEC60335_2_6J - ATTACHMENT
Clause Requirement – Test Result – Remark Verdict
IEC60335_2_6J - ATTACHMENT
Clause Requirement – Test Result – Remark Verdict
IEC60335_2_6J - ATTACHMENT
Clause Requirement – Test Result – Remark Verdict
IEC60335_2_6J - ATTACHMENT
Clause Requirement – Test Result – Remark Verdict
22.ZE.9 Appliances fitted with means to isolate them from all N/A
energy sources
Such isolators are clearly identified, and N/A
ZF ANNEX ZF (INFORMATIVE)
CRITERIA APPLIED FOR THE ALLOCATION OF PRODUCTS COVERED BY
STANDARDS IN THE EN 60335 SERIES UNDER LVD OR MD
List of standards under CENELEC/TC61 with the LVD P
allocation under the LVD (Low Voltage Directive) or
the MD (Machinery Directive) ................................ :
ZG ANNEX ZG (NORMATIVE)
UV APPLIANCES
The following modifications to this standard apply to N/A
appliances having UV emitters
This annex is not applicable to appliances covered N/A
by the scopes of IEC 60335-2-27, IEC 60335-2-59
or IEC 60335-2-109
7.12.ZG The instructions for appliances incorporating UVC N/A
emitters include the substance of the following:
WARNING — This appliance contains a UV emitter.
Do not stare at the light source
32 For appliances incorporating UV emitters the N/A
manufacturer delivers a declaration providing
evidence that the plastic material exposed to the
radiation is UV resistant
ZZ ANNEX ZZ (INFORMATIVE)
COVERAGE OF ESSENTIAL REQUIREMENTS OF EC DIRECTIVES
Description of the relation between this European P
standard and the LVD (Low Voltage Directive,
2006/95/EC) and the MD (Machinery Directive,
2006/42/EC)
Page 16 of 16 Report No:247713
IEC60335_2_6J - ATTACHMENT
Clause Requirement – Test Result – Remark Verdict
Bare metal 40 45 45
Coated metal 45 55 55
Glass and ceramic 55 60 60
Plastic and plastic coating > 0,3 mm 60 65 65
Page 1 of 3 Report No:247713
the overall dimensions in above drawings also apply to drawings in following 2 pages.
Page 2 of 3 Report No:247713
PHOTOGRAPH - ATTACHMENT
PHOTOGRAPH - ATTACHMENT
Page 3 of 31 Report No:247713
PHOTOGRAPH - ATTACHMENT
PHOTOGRAPH - ATTACHMENT
PHOTOGRAPH - ATTACHMENT
PHOTOGRAPH - ATTACHMENT
PHOTOGRAPH - ATTACHMENT
PHOTOGRAPH - ATTACHMENT
PHOTOGRAPH - ATTACHMENT
PHOTOGRAPH - ATTACHMENT
PHOTOGRAPH - ATTACHMENT
PHOTOGRAPH - ATTACHMENT
PHOTOGRAPH - ATTACHMENT
PHOTOGRAPH - ATTACHMENT
PHOTOGRAPH - ATTACHMENT
PHOTOGRAPH - ATTACHMENT
PHOTOGRAPH - ATTACHMENT
PHOTOGRAPH - ATTACHMENT
PHOTOGRAPH - ATTACHMENT
PHOTOGRAPH - ATTACHMENT
PHOTOGRAPH - ATTACHMENT
PHOTOGRAPH - ATTACHMENT
PHOTOGRAPH - ATTACHMENT
PHOTOGRAPH - ATTACHMENT
Eika BH3715360111xx
Page 25 of 31 Report No:247713
PHOTOGRAPH - ATTACHMENT
EC6700 (prototype)
EC5500 (prototype)
Page 26 of 31 Report No:247713
PHOTOGRAPH - ATTACHMENT
PHOTOGRAPH - ATTACHMENT
PHOTOGRAPH - ATTACHMENT
New optional
bracket for
improved
fixing.
Without
optional
bracket for
improved
fixing.
Page 29 of 31 Report No:247713
PHOTOGRAPH - ATTACHMENT
New bracket
for improved
fixing.
Without
optional
bracket for
improved
fixing.
Page 30 of 31 Report No:247713
PHOTOGRAPH - ATTACHMENT
PHOTOGRAPH - ATTACHMENT