Test Report Iec 60335-2-6

Download as pdf or txt
Download as pdf or txt
You are on page 1of 171

Test Report issued under the responsibility of

www.nemko.com

TEST REPORT
IEC 60335-2-6
Safety of household and similar electrical appliances
Part 2: Particular requirements for stationary cooking ranges, hobs,
ovens and similar appliances
Report Reference No. ..................... : 247713
Date of issue ..................................... : 2013-12-09
Total number of pages ...................... : 118

CB Testing Laboratory ................... : Nemko AS Phone: (+47) 22 96 03 30


Address ............................................. : Gaustadalléen 30, N-0373 Oslo, Norway
Applicant’s name ............................ : Tecnowind S.p.A.
Address ............................................. : Via Piani Marischio, 19, I – 60044 Fabriano (AN), Italy
Test specification:
Standard ........................................... : IEC 60335-2-6:2002 (Fifth edition) + A1:2004 + A2:2008 in
conjunction with IEC 60335-1:2010 (Fifth Edition)
Test procedure.................................. : CB
Non-standard test method…………..: N/A
Test Report Form No. ..................... : IEC60335_2_6J
Test Report Form(s) Originator ...................... : LCIE.
Master TRF .................................................... : Dated 2013-05

Copyright © 2013 IEC System for Conformity Testing and Certification of Electrical Equipment
(IECEE), Geneva, Switzerland. All rights reserved.
This publication may be reproduced in whole or in part for non-commercial purposes as long as the IECEE is acknowledged as
copyright owner and source of the material. IECEE takes no responsibility for and will not assume liability for damages resulting from
the reader's interpretation of the reproduced material due to its placement and context.

If this Test Report Form is used by non-IECEE members, the IECEE/IEC logo and the reference to the CB Scheme
procedure shall be removed.
This report is not valid as a CB Test Report unless signed by an approved CB Testing Laboratory and appended
to a CB Test Certificate issued by an NCB in accordance with IECEE 02.

Test item description .................... : Hobs for building-in (Radiant hob elements)
Trade Mark ....................................... :

Manufacturer..................................... : Same as applicant


Model/Type reference ....................... : P58...... (see page 6-12 for model explanation)
Ratings .............................................. : 5,1kW to 6,9kW 220-240V 2/3~ 380-415V 2N/3N~ 50/60Hz,
Cl. I

This Test Report, when bearing the Nemko name and logo is only valid when issued by a Nemko laboratory, or by a
laboratory having special agreement with Nemko.
Page 2 of 118 Report No:247713

Testing procedure and testing location:

CB Testing Laboratory: Nemko AS


Testing location/ address ....................... : Gaustadalléen 30, 0373 Oslo
Norway
Associated CB Laboratory:
Testing location/ address ....................... :

Tested by (name + signature)...... : Victor He


Approved by (+ signature) ........... : Asmund Jensen
Testing procedure: TMP
Tested by (name + signature)...... :
Approved by (+ signature) ............ :
Testing location/ address ....................... :

Testing procedure: WMT


Tested by (name + signature)...... :
Witnessed by (+ signature) ........... :
Approved by (+ signature) ........... :
Testing location/ address ....................... :

Testing procedure: SMT


Tested by (name + signature)...... :
Approved by (+ signature) ............ :
Supervised by (+ signature) ......... :
Testing location/ address ................. :

Testing procedure: RMT


Tested by (name + signature)...... :
Approved by (+ signature) ............ :
Supervised by (+ signature) ......... :
Testing location/ address ....................... :

TRF No. IEC60335_2_6J


Page 3 of 118 Report No:247713

List of Attachments (including a total number of pages in each attachment):

1. EUROPEAN GROUP DIFFERENCES AND NATIONAL DIFFERENCES ( 16 pages)


2. Comparison of normal dimension and slim dimension ( 3 pages)
3. PHOTOGRAPH ( 31 pages)
4. COMPONENT LIST FOR ELECTRONIC CONTROL UNIT 3 ( 3 pages)

Summary of testing:
This test report is upgrade of test report no. 226179 due to add-in alternative components and upgrade of
new edition test standard.
Tests performed (name of test and test clause): Testing location:
The tested samples are found to comply with the Nemko AS
requirements of the relevant product standards.
Gaustadalléen 30
The sample(s) tested complies with the N-0373 Oslo
requirements of standard which listed on first page Norway
and on summary of compliance with national
differences.
Marking label, user manual, packing text:
Instructions and marking shall be in a language
acceptable for the country where the equipment is
to be used.
Other product properties:
Depending on the country where the equipment is to
be used, national deviations may be considered.
Samples of the modified product may be tested
again according to relevant clauses of the product
standard, modified by national deviations.

Summary of compliance with National Differences


List of countries addressed:

CELENEC member countries.

The product fulfils the requirements of following:


EN 60335-2-6 2003 + A1:2003 + A2: 2008 + A11: 2010 + A12:2012 + A13:2013 used in conjunction with
EN 60335-1:2012
EN 62233:2008

TRF No. IEC60335_2_6J


Page 4 of 118 Report No:247713

Copy of marking plate


The artwork below may be only a draft. The use of certification marks on a product must be
authorized by the respective NCBs that own these marks.

The marking plates for the other models are the same as above label except the model name and rating.

Calibration All instruments used in the tests given in this test report are calibrated and
traceable to national or international standards.
Further information about traceability will be given on request.
Measurement Measurement uncertainties are calculated for all instruments and instrument
uncertainty set-ups given in this report. Calculations are based on the principles given in
the standard EA-4/02 (Dec. 1999), IEC Guide 115:2007 and other relevant
internal Nemko-procedures.
Further information about measurement uncertainties will be given on request.
Evaluation of results If not explicitly stated otherwise in the standard, the test is passed if the
measured value is equal to or below (above) the limit line, regardless of the
measurement uncertainty. If the measured value is above (below) the limit line,
the test is not passed - ref IEC Guide 115:2007. The instrumentation accuracy is
within limits agreed by IECEE-CTL.

TRF No. IEC60335_2_6J


Page 5 of 118 Report No:247713

Test item particulars .................................................. : Hobs for building-in (Radiant hob elements)
Classification of installation and use ...................... : Built-in appliance (Recessed), unattended use
Supply Connection .................................................... : Supply cord for permanent connection to fixed wiring;
type X attachment
...................................................................................... :
Possible test case verdicts:
- test case does not apply to the test object............ : N/A
- test object does meet the requirement .................. : P (Pass)
- test object does not meet the requirement ........... : F (Fail)
Testing .......................................................................... :
Date of receipt of test item ......................................... : 2013-10-16
Date (s) of performance of tests ............................... : 2013-10-16 to 2013-10-19

General remarks:
The test results presented in this report relate only to the object tested.
This report shall not be reproduced, except in full, without the written approval of the Issuing testing
laboratory.
"(see Enclosure #)" refers to additional information appended to the report.
"(see appended table)" refers to a table appended to the report.

Throughout this report a comma / point is used as the decimal separator.

Manufacturer’s Declaration per sub-clause 6.2.5 of IECEE 02:


The application for obtaining a CB Test Certificate Yes
includes more than one factory location and a
Not applicable
declaration from the Manufacturer stating that the
sample(s) submitted for evaluation is (are)
representative of the products from each factory
has been provided ...................................................... :

When differences exist; they shall be identified in the General product information section.
Name and address of factory (ies) .......................... : Tecnowind S.p.A.
Via Piani Marischio, 19,
I – 60044 Fabriano (AN),
Italy

TRF No. IEC60335_2_6J


Page 6 of 118 Report No:247713

General product information:

The report applies to built-in hobs of the TYPE: P58…… (3 or 4 hob elements) which has the
following electrical features:
- Power Input : From 5.1kW up to 6.9kW;
- Supply voltage : 220-240V 2/3  or 380-415V 2N/3N  (with different connection)
- Frequency : 50/60Hz.

For appliances without electronic board, the temperature control is managed by thermostats
integrated in each heating element.
In appliances with electronic board the temperature control is managed by electronic regulator and
by thermostats integrated in each heating element.

The appliances are sold with supply cord (Type X attachment) and without plug. It is for permanent
connection to supply mains

The following variants are covered by this test report:


No. Type Model Rated Power Rated Voltage

1. P58…… EO5100 5.1kW 220-240V 2/3 or 380-415V 2N/3N

2. P58…… EO5200 5.2kW 220-240V 2/3 or 380-415V 2N/3N

3. P58…… EO5300 5.3kW 220-240V 2/3 or 380-415V 2N/3N

4. P58…… EO5400 5.4kW 220-240V 2/3 or 380-415V 2N/3N

5. P58…… EO5410 5.4kW 220-240V 2/3 or 380-415V 2N/3N

6. P58…… EO5500 5.5kW 220-240V 2/3 or 380-415V 2N/3N

7. P58…… EO5600 5.6kW 220-240V 2/3 or 380-415V 2N/3N

8. P58…… EO5700 5.7kW 220-240V 2/3 or 380-415V 2N/3N

9. P58…… EO5800 5.8kW 220-240V 2/3 or 380-415V 2N/3N

10. P58…… EO5900 5.9kW 220-240V 2/3 or 380-415V 2N/3N

11. P58…… EO6000 6.0kW 220-240V 2/3 or 380-415V 2N/3N

12. P58…… EO6100 6.1kW 220-240V 2/3 or 380-415V 2N/3N

13. P58…… EO6200 6.2kW 220-240V 2/3 or 380-415V 2N/3N

14. P58…… EO6300 6.3kW 220-240V 2/3 or 380-415V 2N/3N

15. P58…… EO6400 6.4kW 220-240V 2/3 or 380-415V 2N/3N

16. P58…… EV5400 5.4kW 220-240V 2/3 or 380-415V 2N/3N

17. P58…… EV5500 5.5kW 220-240V 2/3 or 380-415V 2N/3N

18. P58…… EV5600 5.6kW 220-240V 2/3 or 380-415V 2N/3N

19. P58…… EV5700 5.7kW 220-240V 2/3 or 380-415V 2N/3N

20. P58…… EV5800 5.8kW 220-240V 2/3 or 380-415V 2N/3N

21. P58…… EV5900 5.9kW 220-240V 2/3 or 380-415V 2N/3N

22. P58…… EV6000 6.0kW 220-240V 2/3 or 380-415V 2N/3N

TRF No. IEC60335_2_6J


Page 7 of 118 Report No:247713

No. Type Model Rated Power Rated Voltage

23. P58…… EV6100 6.1kW 220-240V 2/3 or 380-415V 2N/3N

24. P58…… EV6200 6.2kW 220-240V 2/3 or 380-415V 2N/3N

25. P58…… EV6300 6.3kW 220-240V 2/3 or 380-415V 2N/3N

26. P58…… EV6400 6.4kW 220-240V 2/3 or 380-415V 2N/3N

27. P58…… RO5400 5.4kW 220-240V 2/3 or 380-415V 2N/3N

28. P58…… RO5500 5.5kW 220-240V 2/3 or 380-415V 2N/3N

29. P58…… RO5600 5.6kW 220-240V 2/3 or 380-415V 2N/3N

30. P58…… RO5700 5.7kW 220-240V 2/3 or 380-415V 2N/3N

31. P58…… RO5800 5.8kW 220-240V 2/3 or 380-415V 2N/3N

32. P58…… RO5900 5.9kW 220-240V 2/3 or 380-415V 2N/3N

33. P58…… RO6000 6.0kW 220-240V 2/3 or 380-415V 2N/3N

34. P58…… RO6100 6.1kW 220-240V 2/3 or 380-415V 2N/3N

35. P58…… RO6200 6.2kW 220-240V 2/3 or 380-415V 2N/3N

36. P58…… RO6300 6.3kW 220-240V 2/3 or 380-415V 2N/3N

37. P58…… RO6400 6.4kW 220-240V 2/3 or 380-415V 2N/3N

38. P58…… RV5400 5.4kW 220-240V 2/3 or 380-415V 2N/3N

39. P58…… RV5500 5.5kW 220-240V 2/3 or 380-415V 2N/3N

40. P58…… RV5600 5.6kW 220-240V 2/3 or 380-415V 2N/3N

41. P58…… RV5700 5.7kW 220-240V 2/3 or 380-415V 2N/3N

42. P58…… RV5800 5.8kW 220-240V 2/3 or 380-415V 2N/3N

43. P58…… RV5900 5.9kW 220-240V 2/3 or 380-415V 2N/3N

44. P58…… RV6000 6.0kW 220-240V 2/3 or 380-415V 2N/3N

45. P58…… RV6100 6.1kW 220-240V 2/3 or 380-415V 2N/3N

46. P58…… RV6200 6.2kW 220-240V 2/3 or 380-415V 2N/3N

47. P58…… RV6300 6.3kW 220-240V 2/3 or 380-415V 2N/3N

48. P58…… RV6400 6.4kW 220-240V 2/3 or 380-415V 2N/3N

49. P58…… RE5400 5.4kW 220-240V 2/3 or 380-415V 2N/3N

50. P58…… RE5500 5.5kW 220-240V 2/3 or 380-415V 2N/3N

51. P58…… RE5600 5.6kW 220-240V 2/3 or 380-415V 2N/3N

52. P58…… RE5700 5.7kW 220-240V 2/3 or 380-415V 2N/3N

53. P58…… RE5800 5.8kW 220-240V 2/3 or 380-415V 2N/3N

54. P58…… RE5900 5.9kW 220-240V 2/3 or 380-415V 2N/3N

55. P58…… RE6000 6.0kW 220-240V 2/3 or 380-415V 2N/3N

TRF No. IEC60335_2_6J


Page 8 of 118 Report No:247713

No. Type Model Rated Power Rated Voltage

56. P58…… RE6100 6.1kW 220-240V 2/3 or 380-415V 2N/3N

57. P58…… RE6200 6.2kW 220-240V 2/3 or 380-415V 2N/3N

58. P58…… RE6300 6.3kW 220-240V 2/3 or 380-415V 2N/3N

59. P58…… RE6400 6.4kW 220-240V 2/3 or 380-415V 2N/3N

60. P58…… RE6500 6.5kW 220-240V 2/3 or 380-415V 2N/3N

61. P58…… RE6600 6.6kW 220-240V 2/3 or 380-415V 2N/3N

62. P58…… RE6700 6.7kW 220-240V 2/3 or 380-415V 2N/3N

63. P58…… RE6800 6.8kW 220-240V 2/3 or 380-415V 2N/3N

64. P58…… RB5400 5.4kW 220-240V 2/3 or 380-415V 2N/3N

65. P58…… RB5500 5.5kW 220-240V 2/3 or 380-415V 2N/3N

66. P58…… RB5600 5.6kW 220-240V 2/3 or 380-415V 2N/3N

67. P58…… RB5700 5.7kW 220-240V 2/3 or 380-415V 2N/3N

68. P58…… RB5800 5.8kW 220-240V 2/3 or 380-415V 2N/3N

69. P58…… RB5900 5.9kW 220-240V 2/3 or 380-415V 2N/3N

70. P58…… RB6000 6.0kW 220-240V 2/3 or 380-415V 2N/3N

71. P58…… RB6100 6.1kW 220-240V 2/3 or 380-415V 2N/3N

72. P58…… RB6200 6.2kW 220-240V 2/3 or 380-415V 2N/3N

73. P58…… RB6300 6.3kW 220-240V 2/3 or 380-415V 2N/3N

74. P58…… RB6400 6.4kW 220-240V 2/3 or 380-415V 2N/3N

75. P58…… RB6500 6.5kW 220-240V 2/3 or 380-415V 2N/3N

76. P58…… RB6600 6.6kW 220-240V 2/3 or 380-415V 2N/3N

77. P58…… RB6700 6.7kW 220-240V 2/3 or 380-415V 2N/3N

78. P58…… RB6800 6.8kW 220-240V 2/3 or 380-415V 2N/3N

79. P58…… MO5400 5.4kW 220-240V 2/3 or 380-415V 2N/3N

80. P58…… MO5500 5.5kW 220-240V 2/3 or 380-415V 2N/3N

81. P58…… MO5600 5.6kW 220-240V 2/3 or 380-415V 2N/3N

82. P58…… MO5700 5.7kW 220-240V 2/3 or 380-415V 2N/3N

83. P58…… MO5800 5.8kW 220-240V 2/3 or 380-415V 2N/3N

84. P58…… MO5900 5.9kW 220-240V 2/3 or 380-415V 2N/3N

85. P58…… MO6000 6.0kW 220-240V 2/3 or 380-415V 2N/3N

86. P58…… MO6100 6.1kW 220-240V 2/3 or 380-415V 2N/3N

87. P58…… MO6200 6.2kW 220-240V 2/3 or 380-415V 2N/3N

88. P58…… MO6300 6.3kW 220-240V 2/3 or 380-415V 2N/3N

TRF No. IEC60335_2_6J


Page 9 of 118 Report No:247713

No. Type Model Rated Power Rated Voltage

89. P58…… MO6400 6.4kW 220-240V 2/3 or 380-415V 2N/3N

90. P58…… MV5400 5.4kW 220-240V 2/3 or 380-415V 2N/3N

91. P58…… MV5500 5.5kW 220-240V 2/3 or 380-415V 2N/3N

92. P58…… MV5600 5.6kW 220-240V 2/3 or 380-415V 2N/3N

93. P58…… MV5700 5.7kW 220-240V 2/3 or 380-415V 2N/3N

94. P58…… MV5800 5.8kW 220-240V 2/3 or 380-415V 2N/3N

95. P58…… MV5900 5.9kW 220-240V 2/3 or 380-415V 2N/3N

96. P58…… MV6000 6.0kW 220-240V 2/3 or 380-415V 2N/3N

97. P58…… MV6100 6.1kW 220-240V 2/3 or 380-415V 2N/3N

98. P58…… MV6200 6.2kW 220-240V 2/3 or 380-415V 2N/3N

99. P58…… MV6300 6.3kW 220-240V 2/3 or 380-415V 2N/3N

100. P58…… MV6400 6.4kW 220-240V 2/3 or 380-415V 2N/3N

101. P58…… ME5400 5.4kW 220-240V 2/3 or 380-415V 2N/3N

102. P58…… ME5500 5.5kW 220-240V 2/3 or 380-415V 2N/3N

103. P58…… ME5600 5.6kW 220-240V 2/3 or 380-415V 2N/3N

104. P58…… ME5700 5.7kW 220-240V 2/3 or 380-415V 2N/3N

105. P58…… ME5800 5.8kW 220-240V 2/3 or 380-415V 2N/3N

106. P58…… ME5900 5.9kW 220-240V 2/3 or 380-415V 2N/3N

107. P58…… ME6000 6.0kW 220-240V 2/3 or 380-415V 2N/3N

108. P58…… ME6100 6.1kW 220-240V 2/3 or 380-415V 2N/3N

109. P58…… ME6200 6.2kW 220-240V 2/3 or 380-415V 2N/3N

110. P58…… ME6300 6.3kW 220-240V 2/3 or 380-415V 2N/3N

111. P58…… ME6400 6.4kW 220-240V 2/3 or 380-415V 2N/3N

112. P58…… ME6500 6.5kW 220-240V 2/3 or 380-415V 2N/3N

113. P58…… ME6600 6.6kW 220-240V 2/3 or 380-415V 2N/3N

114. P58…… ME6700 6.7kW 220-240V 2/3 or 380-415V 2N/3N

115. P58…… ME6800 6.8kW 220-240V 2/3 or 380-415V 2N/3N

116. P58…… MB5400 5.4kW 220-240V 2/3 or 380-415V 2N/3N

117. P58…… MB5500 5.5kW 220-240V 2/3 or 380-415V 2N/3N

118. P58…… MB5600 5.6kW 220-240V 2/3 or 380-415V 2N/3N

119. P58…… MB5700 5.7kW 220-240V 2/3 or 380-415V 2N/3N

120. P58…… MB5800 5.8kW 220-240V 2/3 or 380-415V 2N/3N

121. P58…… MB5900 5.9kW 220-240V 2/3 or 380-415V 2N/3N

TRF No. IEC60335_2_6J


Page 10 of 118 Report No:247713

No. Type Model Rated Power Rated Voltage

122. P58…… MB6000 6.0kW 220-240V 2/3 or 380-415V 2N/3N

123. P58…… MB6100 6.1kW 220-240V 2/3 or 380-415V 2N/3N

124. P58…… MB6200 6.2kW 220-240V 2/3 or 380-415V 2N/3N

125. P58…… MB6300 6.3kW 220-240V 2/3 or 380-415V 2N/3N

126. P58…… MB6400 6.4kW 220-240V 2/3 or 380-415V 2N/3N

127. P58…… MB6500 6.5kW 220-240V 2/3 or 380-415V 2N/3N

128. P58…… MB6600 6.6kW 220-240V 2/3 or 380-415V 2N/3N

129. P58…… MB6700 6.7kW 220-240V 2/3 or 380-415V 2N/3N

130. P58…… MB6800 6.8kW 220-240V 2/3 or 380-415V 2N/3N

131. P58…… CO5800 5.8kW 220-240V 2/3 or 380-415V 2N/3N

132. P58…… CO6200 6.2kW 220-240V 2/3 or 380-415V 2N/3N

133. P58…… CV5800 5.8kW 220-240V 2/3 or 380-415V 2N/3N

134. P58…… CV6200 6.2kW 220-240V 2/3 or 380-415V 2N/3N

135. P58…… CE5800 5.8kW 220-240V 2/3 or 380-415V 2N/3N

136. P58…… CE6200 6.2kW 220-240V 2/3 or 380-415V 2N/3N

137. P58…… CB5800 5.8kW 220-240V 2/3 or 380-415V 2N/3N

138. P58…… CB6200 6.2kW 220-240V 2/3 or 380-415V 2N/3N

139. P58 …… EO6800 6.8kW 220-240V 2/3 or 380-415V 2N/3N

140. P58 …… EV6800 6.8kW 220-240V 2/3 or 380-415V 2N/3N

141. P58 …… EO6700 6.7kW 220-240V 2/3 or 380-415V 2N/3N

142. P58 …… EV6700 6.7kW 220-240V 2/3 or 380-415V 2N/3N

143. P58 …… EO6600 6.6kW 220-240V 2/3 or 380-415V 2N/3N

144. P58 …… EV6600 6.6kW 220-240V 2/3 or 380-415V 2N/3N

145. P58 …… EO6500 6.5kW 220-240V 2/3 or 380-415V 2N/3N

146 P58 …… EV6500 6.5kW 220-240V 2/3 or 380-415V 2N/3N

147 P58…… EC6000 6.0kW 220-240V 2/3 or 380-415V 2N/3N


)
148 P58…… EC6300 * 6.3kW 220-240V 2/3 or 380-415V 2N/3N
)
149 P58…… EC6700 * 6.7kW 220-240V 2/3 or 380-415V 2N/3N

150 P58…… EV6700 6.7kW 220-240V 2/3 or 380-415V 2N/3N


)
151 P58…… EC5400 * 5.4kW 220-240V 2/3 or 380-415V 2N/3N
)
152 P58…… EC5500 * 5.5kW 220-240V 2/3 or 380-415V 2N/3N

153 P58…… EO6400 6.4kW 220-240V 2/3 or 380-415V 2N/3N

No. Type Model Rated Power Rated Voltage

TRF No. IEC60335_2_6J


Page 11 of 118 Report No:247713

154 P58…… EO6900 6.9kW 220-240V 2/3 or 380-415V 2N/3N

155 P58…… EC6400 6.4kW 220-240V 2/3 or 380-415V 2N/3N


)
* the recessed part possible to be normal dimension and slim dimension. See attachment -
Comparison of normal dimension and slim dimension for detail.

Explanation of the Type reference:

P58 =Piano (Built-in hobs), 58cm width


The six dots are equal to the Model reference, see below

Explanation of the Model reference:


1.letter (type of command) = E (Electronic); R (energy Regulator);
M (Mixed, commutators and energy regulators); C (Commutators = rotary switch)

2.letter (command position) = V (Vertical); O (Horizontal); E (External); B (Below); C (Horizontal Central)


The 4 next figures =Power Input (in Watts); From 5100 up to 6900, depending
on the combination of hob elements.

The appliance fulfills the requirements of the relevant standards when installed as described in the
instruction manual (see also clause 7.12.4):

The appliance possible equipped with additional optional fixing device for supplement the fixing of heating
elements. See last 2 pages of photograph attachment for details.

TRF No. IEC60335_2_6J


Page 12 of 118 Report No:247713

Dimensions in mm. (alternative slim dimension for some models. see model list in General product
information and attachment - Comparison of normal dimension and slim dimension for details)

In order to identify elements, this scheme has to be considered when reading test results in the following
sections.

HOB HOB
No. 2 No. 3

HOB HOB

No. 1 No. 4
4 cooking positions

HOB

No. 2 HOB

No. 3
HOB

No. 1

3 cooking positions

TRF No. IEC60335_2_6J


Page 13 of 118 Report No:247713

IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict

5 GENERAL CONDITIONS FOR THE TESTS


Tests performed according to cl. 5, e.g. nature of P
supply, sequence of testing, etc.
5.3 Addition: for pyrolitic self-cleaning ovens, the tests of N/A
22.108 to 22.111 are carried out before the tests of
Clause 19 (IEC 60335-2-6 : 2002)
5.4 Addition: appliances that also use gas are supplied N/A
with gas at the appropriate rated pressure. Vessels
having a diameter of approximately 220mm are filled
with 2 l of water, covered with a lid and placed on the
hob burners. The controls are adjusted so that the
water simmers, water being added when necessary to
maintain the level (IEC 60335-2-6 : 2002)
5.101 Class III temperature-sensing probes are only N/A
subjected to the tests of Clause 19 (IEC 60335-2-6 :
2002)

6 CLASSIFICATION
6.1 Protection against electric shock: Class I P
Class I, II, III (IEC 60335-2-6 : 2002):
6.2 Protection against harmful ingress of water IPX0 N/A

7 MARKING AND INSTRUCTIONS


7.1 Rated voltage or voltage range (V) .......................... : 220-240V 2/3~ P
380-415V 2N/3N~
Nature of supply ....................................................... : ~ P
Rated frequency (Hz) ............................................... : 50/60Hz P
Rated power input (W) ............................................. : 5,1kW to 6,9kW, P
see page 6-12 for details.
Rated current (A) ..................................................... : N/A
For induction hob elements and induction wok N/A
elements(IEC 60335-2-6 : 2002)
total rated power input or rated current
Manufacturer's or responsible vendor's name, P
trademark or identification mark .............................. :
Model or type reference ........................................... : P58…… (see page 6-12 for P
model explanation)
Symbol 5172 of IEC 60417, for Class II appliances N/A
IP number, other than IPX0 ..................................... : N/A

TRF No. IEC60335_2_6J


Page 14 of 118 Report No:247713

IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict

Symbol IEC 60417-5036, for the enclosure of N/A


electrically-operated water valves in external hose-
sets for connection of an appliance to the water mains
Marking of the rated current of the fuse other than N/A
D-type fuse for cooking ranges incorporate a socket-
outlet. (IEC 60335-2-6 : 2002)
Marking of the rated current of the fuse other than N/A
D-type fuse (IEC 60335-2-6 : 2002)
7.2 Warning for stationary appliances for multiple supply N/A
Warning placed in vicinity of terminal cover N/A
7.3 Range of rated values marked with the lower and 220-240V P
upper limits separated by a hyphen 380-415V

Different rated values marked with the values 50/60Hz P


separated by an oblique stroke 2/3~ 2N/3N~

7.4 Appliances adjustable for different rated voltages, the N/A


voltage setting is clearly discernible
Requirement met if frequent changes are not N/A
required and the rated voltage to which the appliance
is to be adjusted is determined from a wiring diagram
7.5 Appliances with more than one rated voltage or one or N/A
more rated voltage ranges, marked with rated input or
rated current for each rated voltage or range, unless
the power input is related to the arithmetic mean value P
of the rated voltage range
Relation between marking for upper and lower limits of N/A
rated power input or rated current and voltage is clear
7.6 Correct symbols used P
Symbol for nature of supply placed next to rated P
voltage
Symbol for class II appliances placed unlikely to be N/A
confused with other marking
Units of physical quantities and their symbols P
according to international standardized system
Symbol IEC 60417-5010: ON/OFF (push-push) (IEC P
60335-2-6 : 2002)
7.7 Connection diagram fixed to appliances to be N/A
connected to more than two supply conductors and
appliances for multiple supply
correct mode of connection is obvious P
7.8 Except for type Z attachment, terminals for connection to the supply mains indicated P
as follows:

TRF No. IEC60335_2_6J


Page 15 of 118 Report No:247713

IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict

- marking of terminals exclusively for the neutral P


conductor (letter N)
- marking of protective earthing terminals (symbol P
IEC 60417-5019)
- marking not placed on removable parts P
7.9 Marking or placing of switches which may cause a P
hazard
7.10 Indications of switches on stationary appliances and +, - and symbol for key, P
controls on all appliances by use of figures, letters or standard symbol for ON/OFF
other visual means ..................................... ......... :
This applies also to switches which are part of a P
control
If figures are used, the off position indicated by the P
figure 0
The figure 0 indicates only OFF position, unless no P
confusion with the OFF position
The figure 0 indicates OFF position and figure I For electronic touch control P
indicates ON position of touch controls for hobs or model
(IEC 60335-2-6:2002)
for each hob element (IEC 60335-2-6:2002) N/A
7.11 Indication for direction of adjustment of controls P
7.12 Instructions for safe use provided P
Details concerning precautions during user P
maintenance
The instructions state that: -
- the appliance is not to be used by persons P
(including children) with reduced physical, sensory or
mental capabilities, or lack of experience and
knowledge, unless they have been given supervision
or instruction
- children being supervised not to play with the P
appliance
For a part of class III construction supplied from a N/A
detachable power supply unit, the instructions state
that the appliance is only to be used with the unit
provided
Instructions for class III appliances state that it must N/A
only be supplied at SELV, unless
it is a battery-operated appliance, the battery being N/A
charged outside the appliance
Instructions shall include the following: (IEC 60335-2-6:2002) -

TRF No. IEC60335_2_6J


Page 16 of 118 Report No:247713

IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict

Warning: If the surface is cracked, switch off the P


appliance to avoid the possibility of electric shock, for
hob surfaces of glass-ceramic or similar material
which protect live parts
During use the appliances becomes hot. Care N/A
should be taken to avoid touching heating elements
inside the oven, for cooking ranges and ovens
Instructions for ovens: (IEC 60335-2-6:2002) -
Warning: Accessible parts may become hot during N/A
use. Young children should be kept away.
Instructions for ovens having doors with glass panels: (IEC 60335-2-6:2002) -
Do not use harsh abrasive cleaners or sharp metal N/A
scrapers to clean the oven door glass since they can
scratch the surface, which may result in shattering of
the glass.
If during the test of Clause 11, the temperature rise N/A
at the centre of the internal bottom surface of a
storage drawer exceeds that specified for handles
held for short periods in normal use, the instruction
shall state that these surfaces can get hot.
Instructions for pyrolytic self-cleaning ovens shall: (IEC 60335-2-6:2002) -
- state that excess spillage must be remove before N/A
cleaning
- specify which utensils can be left in the oven during N/A
cleaning
Instructions shall state for cleaning used to set the controls to a position higher than -
for normal cooking purposes: (IEC 60335-2-6:2002)
- that under such conditions the surfaces may be get N/A
hotter than usual
- children should be kept away N/A
Instructions for ovens incorporating a fan with a guard that can removed for cleaning -
shall state that: (IEC 60335-2-6:2002)
- the oven must be switched off before removing the N/A
guard and
- after cleaning, the guard must be replaced in N/A
accordance with instructions
Instructions for ovens provided with a facility to use a temperature-probe shall include -
the following: (IEC 60335-2-6:2002)
-Only use the temperature probe recommended for N/A
this oven
Instructions for cooking ranges, hobs and oven (IEC 60335-2-6:2002) -
-shall state a steam cleaner is not be used P
Instructions for induction hobs shall state the following: (IEC 60335-2-6:2002) -
-Metallic objects such as knives, forks, spoons and N/A
lids should not be placed on the hob surface since
they can get hot
Instructions for hobs incorporating a lid shall state (IEC 60335-2-6:2002) -
-Any spillage should be removed from the lid before N/A
opening. They also state than that

TRF No. IEC60335_2_6J


Page 17 of 118 Report No:247713

IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict

- Hob surface should be allowed to cool before N/A


closing the lid
Instructions for hobs incorporating halogen lamps -
shall warn the user not to stare at the hob elements
(IEC 60335-2-6:2002)
Instructions for hob incorporating a pan detector shall include the following (IEC -
60335-2-6:2002)
-After use, switch off the hob element by its control N/A
and do not rely on the pan detector
Instructions for appliances incorporating a lamp for illumination, and does not -
incorporate a switch providing full disconnection under overvoltage category shall
state the following: (IEC 60335-2-6:2002)
-Warning - Ensure that the appliance is switched off N/A
before replacing the lamp to avoid the possibility of
electric shock .
The instructions for hobs shall state that the P
appliance is not intended to be operated by means of
external timer or separated remote-control system
(IEC 60335-2-6:2002)
The instructions for hobs incorporating an induction N/A
wok element shall contain a list of vessels that can
be used, unless the manufacturer provides a wok
with the appliance (IEC 60335-2-6:2002)
The instructions for ovens that have shelves shall N/A
include details indicating the correct installation of
the shelves (IEC 60335-2-6:2002)
7.12.1 Sufficient details for installation supplied P
For an appliance intended to be permanently N/A
connected to the water mains and not connected by
a hose-set, this is stated
Instructions concerning cooking ranges placed on N/A
the floor. (60335-2-6: 2002)
maximum rated pressure for appliance intended to N/A
be connected to the water supply. (60335-2-6: 2002)
7.12.2 Stationary appliances not fitted with means for P
disconnection from the supply mains having a contact
separation in all poles that provide full disconnection
under overvoltage category III, the instructions state
that means for disconnection must be incorporated in
the fixed wiring in accordance with the wiring rules
7.12.3 Insulation of the fixed wiring in contact with parts P
exceeding 50 K during clause 11; instructions stating
that the fixed wiring must be protected
Instructions for cooking range does not have a N/A
supply cord shall state the type of cord to be used,
taking into account the temperature of the rear
surface of the appliance (IEC 60335-2-6:2002)
7.12.4 Instructions for built-in appliances: -
- dimensions of space 580 * 510 mm P

TRF No. IEC60335_2_6J


Page 18 of 118 Report No:247713

IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict

- dimensions and position of supporting means P


- distances between parts and surrounding structure Side: 50 mm P
Rear side: 53.5 mm
Bottom side: 25 mm
- dimensions of ventilation openings and arrangement N/A
- connection to supply mains and interconnection of P
separate components
- allow disconnection of the appliance after installation, A switch in the fixed wiring P
by accessible plug or a switch in the fixed wiring,
unless
a switch complying with 24.3 N/A
Instructions for built-in appliances having a separate Only for models with E as the P
control panels shall state the control panel is only to second letter
be connected to heating units specified in order to
avoid a possible hazard (IEC 60335-2-6:2002)
7.12.5 Replacement cord instructions, type X attachment with Without special preparation P
a specially prepared cord
Replacement cord instructions, type Y attachment N/A
Replacement cord instructions, type Z attachment N/A
7.12.6 Caution in the instructions for heating appliances with N/A
a non-self-resetting thermal cut-out
7.12.7 Instructions for fixed appliances stating how the P
appliance is to be fixed
7.12.8 Instructions for appliances connected to the water mains: -
- max. inlet water pressure (Pa)............................... : N/A
- min. inlet water pressure, if necessary (Pa) .......... : N/A
Instructions concerning new and old hose-sets for N/A
appliances connected to the water mains by
detachable hose-sets
7.13 Instructions and other texts in an official language English version checked only. P
Manual will be provided in the
official language of the
countries that the appliances
are to be sold.
7.14 Marking clearly legible and durable P
7.15 Marking on a main part P
Marking clearly discernible from the outside, if P
necessary after removal of a cover
For portable appliances, cover can be removed or N/A
opened without a tool

TRF No. IEC60335_2_6J


Page 19 of 118 Report No:247713

IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict

For stationary appliances, name, trademark or N/A


identification mark and model or type reference visible
after installation
For fixed appliances, name, trademark or identification N/A
mark and model or type reference visible after
installation according to the instructions
Or included in the instruction of use (IEC 60335-2- P
6:2002)
Or on an additional label fixed near the appliance N/A
after installation (IEC 60335-2-6:2002)
Indications for switches and controls placed on or near P
the components. Marking not on parts which can be
positioned or repositioned in such a way that the
marking is misleading
Marking for rated current of the fuse protecting a N/A
socket-outlet placed on or near the socket-outlet
(IEC 60335-2-6:2002)
7.16 Marking of a possible replaceable thermal link or fuse N/A
link clearly visible with regard to replacing the link
7.101 Marking of the maximum water level, which shall be N/A
visible during filling, for steam generators intended to
filled manually (IEC 60335-2-6:2002)
7.102 Appropriate marking the cooking zone of hob P
surfaces unless (IEC 60335-2-6:2002)
7.103 For cooking ranges that are normally placed on the N/A
floor and that have horizontally hinged oven doors
with a hinge height of less than 430mm from the
floor, if a stabilizing means is necessary in order to
comply with the test of 20.102, then: (IEC 60335-2-
6:2002)
-The stabilizing means shall be marked, in lettering N/A
at least 3mm high, with the substance of the
following warning:
WARNING: in order to prevent tipping of the
appliance, this stabilizing means must be installed.
Refer to the instructions for installation.
-The appliance shall be marked, in lettering at least N/A
3mm high, at the point of supply entry and at least
one other point to draw the attention of the user to
the need to stabilize the appliance.
it is obvious (IEC 60335-2-6:2002) N/A

8 PROTECTION AGAINST ACCESS TO LIVE PARTS


8.1 Adequate protection against accidental contact with P
live parts
8.1.1 Requirement applies for all positions, detachable parts P
removed

TRF No. IEC60335_2_6J


Page 20 of 118 Report No:247713

IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict

Insertion or removal of lamps, protection against N/A


contact with live parts of the lamp cap
Use of test probe B of IEC 61032: no contact with live P
parts
8.1.2 Use of test probe 13 of IEC 61032 through openings P
in class 0 appliances and class II appliances/
constructions: no contact with live parts
Test probe 13 also applied through openings in N/A
earthed metal enclosures having a non-conductive
coating: no contact with live parts
Test probe 12 of IEC 61032 also applied to parts P
liable to be touched accidentally in normal use by a
fork or similar pointed object: no contact with live
parts (IEC 60335-2-6:2002)
8.1.3 For appliances other than class II, use of test probe 41 N/A
of IEC 61032: no contact with live parts of visible
glowing heating elements
Test probe 41: no contact with live parts of visible N/A
glowing heating elements situated at the top of the
oven or grilling compartment. (IEC 60335-2-6:2002)
8.1.4 Accessible part not considered live if: -
- safety extra-low a.c. voltage: peak value not N/A
exceeding 42.4 V
- safety extra-low d.c. voltage: not exceeding 42.4 V N/A
- or separated from live parts by protective impedance N/A
If protective impedance: d.c. current not exceeding N/A
2 mA, and
a.c. peak value not exceeding 0.7 mA N/A
- for peak values over 42.4 V up to and including N/A
450 V, capacitance not exceeding 0,1 F
- for peak values over 450 V up to and including N/A
15 kV, discharge not exceeding 45 C
- for peak values over 15kV, the energy in the N/A
discharge not exceeding 350 mJ
8.1.5 Live parts protected at least by basic insulation before installation or assembly: -
- built-in appliances P
- fixed appliances N/A
- appliances delivered in separate units N/A
8.2 Class II appliances and constructions constructed so P
that there is adequate protection against accidental
contact with basic insulation and metal parts
separated from live parts by basic insulation only

TRF No. IEC60335_2_6J


Page 21 of 118 Report No:247713

IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict

Only possible to touch parts separated from live parts P


by double or reinforced insulation

10 POWER INPUT AND CURRENT


10.1 Power input at normal operating temperature, rated (see appended table) P
voltage and normal operation not deviating from rated
power input by more than shown in table 1
Test carried out at upper and lower limits of the N/A
ranges for appliances with one or more rated voltage
ranges, unless
the rated power input is related to the arithmetic P
mean value
Induction hob elements and induction wok elements: N/A
power input measured separately, tolerances for
motor-appliances apply. (IEC 60335-2-6:2002)
Socket-outlet are not loaded during the test N/A
(IEC 60335-2-6:2002)
10.2 Current at normal operating temperature, rated (see appended table) N/A
voltage and normal operation not deviating from rated
current by more than shown in table 2
Test carried out at upper and lower limits of the N/A
ranges for appliances with one or more rated voltage
ranges, unless
the rated current is related to the arithmetic mean N/A
value of the range
Induction hob elements and induction wok elements: N/A
current measured separately, tolerances for
motor-appliances apply. (IEC 60335-2-6:2002)
Socket-outlet are not loaded during the test N/A
(IEC 60335-2-6:2002)

11 HEATING
11.1 No excessive temperatures in normal use P
For cooking ranges and ovens, compliance is also N/A
checked by the test of 11.101 (IEC 60335-2-6:2002)
11.2 Placing and mounting of appliance as described P
- built-in (IEC 60335-2-6:2002) Acc. to installation instruction P
- against a wall (IEC 60335-2-6:2002) N/A
- on the floor (IEC 60335-2-6:2002) N/A
- fixed to the wall (IEC 60335-2-6:2002) N/A
- with or without the lid covering the hob surface N/A
(IEC 60335-2-6:2002)
- temperature sensing probes: any position likely to N/A
occur during normal use. (IEC 60335-2-6:2002)

TRF No. IEC60335_2_6J


Page 22 of 118 Report No:247713

IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict

- pyrolytic self-cleaning ovens: temperature sensing N/A


probe in position unless other instructions
(IEC 60335-2-6:2002)
Detachable parts that are intended to be used to N/A
reduce the temperature of controls panels are
removed(IEC 60335-2-6:2002)
11.3 Temperature rises, other than of windings, determined P
by thermocouples
Temperature rises of windings determined by P
resistance method, unless
the windings makes it difficult to make the necessary P
connections
11.4 Heating appliances operated under normal operation P = 1,15 * Pn * (240/230)² P
at 1.15 times rated power input ............................... : (see table 11.8)
Induction hob elements and induction wok elements N/A
supplied separately and operated as for motor
operated appliances (IEC 60335-2-6:2002)
Cooking ranges operated under normal operation at N/A
1.15 times rated power input: (IEC 60335-2-6:2002)
11.5 Motor-operated appliances operated under normal N/A
operation at most unfavourable voltage between 0.94
and 1.06 times rated voltage.................................... :
11.6 Combined appliances are operated as specified for N/A
heating appliances. .............. (IEC 60335-2-6: 2002):
If the temperature rise limits are exceeded in N/A
appliances incorporating motors, transformers or
electronic circuits, and the power input is lower than
the rated power input, the test is repeated with the
appliance supplied at 1,06 times rated voltage .
(IEC 60335-2-6: 2002)
11.7 Appliance operated for the duration specified in 11.7.101 to 11.7.106 P
(IEC 60335-2-6)
11.7.101 Induction hob elements and induction wok elements, 60 minutes P
other hob elements :
11.7.102 Ovens : N/A
Steam ovens operated in each mode of operation N/A
Lamps in ovens are not manually switched on N/A
11.7.103 Grills N/A
11.7.104 Griddles N/A
11.7.105 Warming drawers and similar compartments : N/A
11.7.106 Cooking ranges : N/A
11.7.107 Appliance incorporates a socket–outlet with an N/A
appropriate plug complying with IEC60083
11.8 Temperature rises not exceeding values in table 3 (see appended tables) P

TRF No. IEC60335_2_6J


Page 23 of 118 Report No:247713

IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict

Temperatures rises of the floor and floor of the test - other appliances, 70K P
corner, wooden cabinets and rectangular box not
exceeding specified values (IEC 60335-2-6:2002)
During the additional test for pyrolytic self-cleaning P
ovens, the temperature rise of the surface of knobs,
handles and levers shall not exceed specified values
(IEC 60335-2-6:2002)
Sealing compound does not flow out P
Protective devices do not operate, except P
components in protective electronic circuits tested for N/A
the number of cycles specified in 24.1.4
11.101 Cooking ranges and ovens placed as described N/A
(IEC 60335-2-6:2002)
Appliance operated under normal operation at rated N/A
voltage :
The appliance operated in specified conditions N/A
The appliance operated 60 min or N/A
until steady conditions are established N/A
Temperature rise of surfaces not exceed the values (see appended tables) N/A
specified in Table 102 (IEC 60335-2-6:2002)

13 LEAKAGE CURRENT AND ELECTRIC STRENGTH AT OPERATING


TEMPERATURE
13.1 Leakage current not excessive and electric strength P
adequate
2
Heating appliances operated at 1.15 times rated P = 1,15 x Pn x (240/230) P
power input ............................................................... : (see table 13.1)
Motor-operated appliances and combined appliances N/A
supplied at 1.06 times rated voltage ........................ :
Protective impedance and radio interference filters N/A
disconnected before carrying out the tests
If a grill is incorporated in the oven, either the oven N/A
or the grill is operated, whichever is more
unfavourable. (IEC 60335-2-6:2002)
For hobs, the tests are carried out with a vessel filled P
as specified in 3.1.9.101 placed on each cooking
zone (IEC 60335-2-6:2002)
Induction hob elements and induction wok elements N/A
are tested as specified for motor-operated
appliances (IEC 60335-2-6:2002)
13.2 Leakage current measured by means of the circuit P
described in figure 4 of IEC 60990
Leakage current measurements (see appended table) P
13.3 The appliance is disconnected from the supply P
Electric strength tests according to table 4 (see appended table) P

TRF No. IEC60335_2_6J


Page 24 of 118 Report No:247713

IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict

No breakdown during the tests P

14 TRANSIENT OVERVOLTAGES
Appliances withstand the transient overvoltages to N/A
which they may be subjected
Clearances having a value less than specified in table (see appended table) N/A
16 subjected to an impulse voltage test, the test
voltage specified in table 6
No flashover during the test, unless of functional N/A
insulation
In case of flashover of functional insulation, the N/A
appliance complies with clause 19 with the clearance
short circuited

15 MOISTURE RESISTANCE
15.1 Enclosure provides the degree of moisture protection N/A
according to classification of the appliance
Compliance checked as specified in 15.1.1, taking into N/A
account 15.1.2, followed by the electric strength test of
16.3
No trace of water on insulation which can result in a N/A
reduction of clearances and creepage distances below
values specified in clause 29
15.1.1 Appliances, other than IPX0, subjected to tests as N/A
specified in IEC 60529 ............................................. :
Water valves in external hoses for connection of an N/A
appliance to the water mains tested as specified for
IPX7 appliances
15.1.2 Hand-held appliance turned continuously through the N/A
most unfavourable positions during the test
Built-in appliances installed according to the N/A
instructions
Appliances placed or used on the floor or table placed N/A
on a horizontal unperforated support
Appliances normally fixed to a wall and appliances N/A
with pins for insertion into socket-outlets are mounted
on a wooden board
For IPX3 appliances, the base of wall mounted N/A
appliances is placed at the same level as the pivot
axis of the oscillating tube

TRF No. IEC60335_2_6J


Page 25 of 118 Report No:247713

IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict

For IPX4 appliances, the horizontal centre line of the N/A


appliance is aligned with the pivot axis of the
oscillating tube
However, for appliances normally used on the floor or N/A
table, the movement is limited to two times 90 for a
period of 5 min, the support being placed at the level
of the pivot axis of the oscillating tube
Appliances normally fixed to a ceiling are mounted N/A
underneath a horizontal unperforated support, the
pivot axis of the oscillating tube located at the level of
the underside of the support
For IPX4 appliances, the movement of the tube is N/A
limited to two times 90 from the vertical for a period of
5 min
Wall-mounted appliances, take into account the N/A
distance to the floor stated in the instructions
Appliances with type X attachment fitted with a flexible N/A
cord as described
Detachable parts tested as specified N/A
15.2 Spillage of liquid does not affect the electrical P
insulation
Appliances incorporating an appliance inlet tested with N/A
or without an connector, whichever is most
unfavourable
Detachable parts removed N/A
Overfilling test with additional amount of water, over a -
period of 1 min, quantity (l) :
Cooking ranges and hobs subjected to the overfilling 0.5 l P
test into the vessel with additional saline solution,
over a period of 15 s (l) .......................................... :
(IEC 60335-2-6:2002)
For hob elements incorporating a switch or a thermal N/A
control: overfilling test with saline solution(l):
(IEC 60335-2-6:2002) ............................................ :
If controls are mounted below the hob surface: N/A
overfilling test with saline solution, over a period of
15 s (l) .................................................................... :
(IEC 60335-2-6:2002)
If controls are mounted in the hob surface: overfilling 0.5 l P
test with saline solution, over them (l) ................... :
(IEC 60335-2-6:2002)
For hob having ventilating openings in the hob N/A
surface: overfilling test with saline solution (l) ....... :
(IEC 60335-2-6:2002)
For ovens and grills: overfilling test with saline N/A
solution (l) .............................................................. :
(IEC 60335-2-6:2002)

TRF No. IEC60335_2_6J


Page 26 of 118 Report No:247713

IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict

For appliances having a drip tray or similar N/A


receptacle: overfilling test with saline solution (l) ... :
(IEC 60335-2-6:2002)
For hobs having a lid: overfilling test with saline N/A
solution (l) .............................................................. :
(IEC 60335-2-6:2002)
Test repeated: overfilling test with saline solution , N/A
over a period of 15 s (l) .......................................... :
(IEC 60335-2-6:2002)
Steam generators intended to be connected to the N/A
water mains supplied at rated water pressure
(IEC 60335-2-6:2002)
Water allowed to flow for 1 min after the first N/A
evidence of overflow, unless (IEC 60335-2-6:2002)
the inflow stops automatically (IEC 60335-2-6:2002) N/A
The appliance withstands the electric strength test of P
16.3
No trace of water on insulation that can result in a P
reduction of clearances and creepage distances below
values specified in clause 29
15.3 Appliances proof against humid conditions P

Checked by test Cab: Damp heat steady state in IEC P


60068-2-78
Humidity test for 48 h in a humidity cabinet P

Reassembly of those parts that may have been N/A


removed
The appliance withstands the tests of clause 16 P

15.101 Temperature-sensing probes shall be constructed so N/A


that their insulation is not affected by water
(IEC 60335-2-6:2002)
After the test, the probe withstand the leakage N/A
current test of 16.2 (IEC 60335-2-6:2002)

16 LEAKAGE CURRENT AND ELECTRIC STRENGTH


16.1 Leakage current not excessive and electric strength P
adequate
Protective impedance disconnected from live parts N/A
before carrying out the tests
Induction hob elements and induction wok elements: N/A
tested as motor-operated appliances (60335-2-6)
16.2 Single-phase appliances: test voltage 1.06 times rated 1,06 x 240V = 254,4V P
voltage ...................................................................... :
Three-phase appliances: test voltage 1.06 times rated 1,06 x 415V / √3 = 254V P
voltage divided by 3 ................................................ :

TRF No. IEC60335_2_6J


Page 27 of 118 Report No:247713

IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict

Leakage current measurements (see appended table) P


16.3 Electric strength tests according to table 7 (see appended table) P
No breakdown during the tests P

17 OVERLOAD PROTECTION OF TRANSFORMERS AND ASSOCIATED CIRCUITS


No excessive temperatures in transformer or (see appended table) N/A
associated circuits in event of short-circuits likely to
occur in normal use
Appliance supplied with 1.06 or 0.94 times rated N/A
voltage and the most unfavourable short-circuit or
overload likely to occur in normal use applied ......... :
Temperature rise of insulation of the conductors of N/A
safety extra-low voltage circuits not exceeding the
relevant value specified in table 3 by more than 15 K
Temperature of the winding not exceeding the value N/A
specified in table 8,
however limits do not apply to fail-safe transformers N/A
complying with sub-clause 15.5 of IEC 61558-1

19 ABNORMAL OPERATION
19.1 The risk of fire or mechanical damage under P
abnormal or careless operation obviated
Electronic circuits so designed and applied that a Only for models with E as the P
fault will not render the appliance unsafe first letter
Appliances incorporating heating elements P
subjected to the tests of 19.2 and 19.3, and
if the appliance also has a control that limit the P
temperature during clause 11 it is subjected to the
test of 19.4, and
if applicable, to the test of 19.5 N/A
Appliances incorporating PTC heating elements are N/A
also subjected to the test of 19.6
Appliances incorporating motors subjected to the N/A
tests of 19.7 to 19.10, as applicable
Appliances incorporating electronic circuits P
subjected to the tests of 19.11 and 19.12, as
applicable
Appliances incorporating contactors or relays P
subjected to the test of 19.14, being carried out
before the tests of 19.11
Appliances incorporating voltage selector switches N/A
subjected to the test of 19.15

TRF No. IEC60335_2_6J


Page 28 of 118 Report No:247713

IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict

Unless otherwise specified, the tests are continued P


until a non-self-resetting thermal cut-out operates,
or
until steady conditions are established P
For induction hobs compliance is also checked by N/A
the test 19.101and 19.102 (19.4 not applicable)
(IEC 60335-2-6:2002)
19.101 is not applicable to induction wok elements N/A
(IEC 60335-2-6:2002)
Temperature-sensing probes placed in the oven in N/A
any position likely to occur during normal use that
they are connected to control the oven temperature
(IEC 60335-2-6:2002)
19.2 Test of appliance with heating elements with P = 0,85 x Pn x (220/230)² P
restricted heat dissipation; test voltage (V): power see appended table
input of 0.85 times rated power input
Hob elements are operated without a vessel, pan P
detectors being rendered inoperative.
Oven doors are open or closed, whichever is more
unfavourable.
Hob lids are closed unless the hob elements are
interlocked with the lid or an indicator lamp shows
that a hob element is switched on. (IEC 60335-2-
6:2002)
For appliances incorporating more than one heating P
unit, the test is only carried with the heating unit
resulting in the most unfavourable conditions, its
control adjusted to the highest setting.
For appliance incorporate an oven without an
indicator lamp to show that the oven is switched on,
the oven is operated, its control adjusted to the
highest setting. (IEC 60335-2-6:2002)
For induction hob element or induction wok element N/A
with a metallic lid: a force of 30N is applied to the
closed lid in the most unfavourable place by means
of test probe B of IEC 61032. (IEC 60335-2-6:2002)
Pyrolytic self-cleaning ovens are also operated N/A
under cleaning conditions, motors which operate
during cleaning being switched off or disconnect in
turn. (IEC 60335-2-6:2002)
Induction hob elements and induction wok elements N/A
are operated under the conditions of clause 11 but
with empty vessels, the controls being adjusted to
the highest setting. (IEC 60335-2-6:2002)
Steam ovens are operated without water (IEC N/A
60335-2-6:2002)
Doors of separate grill compartments incorporate a N/A
cooking range are open or closed, which is the
most unfavourable. (IEC 60335-2-6:2002)

TRF No. IEC60335_2_6J


Page 29 of 118 Report No:247713

IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict

2
19.3 Test of 19.2 repeated; test voltage (V): power input of P = 1,24 x Pn x (240/230) P
1.24 times rated power input.................................... see appended table
19.4 Test conditions as in cl. 11, any control limiting the P
temperature during tests of cl. 11 short-circuited
19.5 Test of 19.4 repeated on Class 0I and I appliances N/A
with tubular sheathed or embedded heating
elements. No short-circuiting, but one end of the
element connected to the elements sheath
The test repeated with reversed polarity and the other N/A
end of the heating element connected to the sheath
The test is not carried out on appliances intended to N/A
be permanently connected to fixed wiring and on
appliances where an all-pole disconnection occurs
during the test of 19.4
19.6 Appliances with PTC heating elements tested at N/A
rated voltage, establishing steady conditions
The working voltage of the PTC heating element is N/A
increased by 5% and the appliance is operated until
steady conditions are re-established. The voltage is
then increased in similar steps until 1.5 times working
voltage or until the PTC heating element ruptures
19.7 Stalling test by locking the rotor if the locked rotor N/A
torque is smaller than the full load torque or locking
moving parts of other appliances
Locked rotor, motor capacitors open-circuited or N/A
short-circuited, if required
Locked rotor, capacitors open-circuited one at a time N/A
Test repeated with capacitors short-circuited one at a N/A
time, unless
capacitor is of class P2 of IEC 60252-1 N/A
Appliances with timer or programmer supplied with N/A
rated voltage for each of the tests, for a period equal
to the maximum period allowed
Other appliances supplied with rated voltage for a N/A
period as specified
Winding temperatures not exceeding values (see appended table) N/A
specified in table 8
19.8 Three-phase motors operated at rated voltage with N/A
one phase disconnected
19.10 Series motor operated at 1.3 times rated voltage for N/A
1 min ......................................................................... :
During the test, parts not being ejected from the N/A
appliance

TRF No. IEC60335_2_6J


Page 30 of 118 Report No:247713

IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict

19.11 Electronic circuits, compliance checked by evaluation P


of the fault conditions specified in 19.11.2 for all
circuits or parts of circuits, unless they comply with
the conditions specified in 19.11.1
Appliances incorporating a protective electronic N/A
circuit subjected to the tests of 19.11.3 and 19.11.4
Appliances incorporating an electronic circuit that In case of restart the P
relies upon a programmable component to function appliance rests in locked
correctly, subjected to the test of 19.11.4.8, unless position. At least two manual
operations are necessary to
restart.
restarting does not result in a hazard N/A
Appliances having a device with an off position P
obtained by electronic disconnection, or a device
placing the appliance in a stand-by mode, subjected
to the tests of 19.11.4
If the safety of the appliance under any of the fault N/A
conditions depends on the operation of a miniature
fuse-link complying with IEC 60127, the test of
19.12 is carried out
During and after each test the following is checked: -

- the temperature of the windings do not exceed the P


values specified in table 8
- the appliance complies with the conditions P
specified in 19.13
- any current flowing through protective impedance N/A
not exceeding the limits specified in 8.1.4
If a conductor of a printed board becomes open- N/A
circuited, the appliance is considered to have
withstood the particular test, provided both of the
following conditions are met:
- the base material of the printed circuit board N/A
withstands the test of Annex E
- any loosened conductor does not reduce N/A
clearance or creepage distances between live parts
and accessible metal parts below the values
specified in clause 29
19.11.1 Before applying the fault conditions a) to f) in 19.11.2, it is checked if circuits or parts of -
circuit meet both of the following conditions:
- the electronic circuit is a low-power circuit, that is, N/A
the maximum power at low-power points does not
exceed 15 W according to the tests specified

TRF No. IEC60335_2_6J


Page 31 of 118 Report No:247713

IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict

- the protection against electric shock, fire hazard, N/A


mechanical hazard or dangerous malfunction in other
parts of the appliance does not rely on the correct
functioning of the electronic circuit
19.11.2 Fault conditions applied one at a time, the appliance operated under conditions -
specified in cl. 11, but supplied at rated voltage, the duration of the tests as specified:
a) short circuit of functional insulation if clearances or N/A
creepage distances are less than the values
specified in 29
b) open circuit at the terminals of any component P
c) short circuit of capacitors, unless they comply with P
IEC 60384-14
d) short circuit of any two terminals of an electronic P
component, other than integrated circuits. This fault
condition is not applied between the two circuits of an
optocoupler
e) failure of triacs in the diode mode N/A
f) failure of an integrated circuit N/A
g) failure of an electronic power switching device N/A
Each low power circuit is short-circuited by N/A
connecting the low-power point to the pole of the
supply source from which the measurements were
made
During simulation it shall possible to switch of any P
energized hob element (IEC 60335-2-6:2002)
The hob elements shall not become energized P
(IEC 60335-2-6:2002)
19.11.3 If the appliance incorporates a protective electronic N/A
circuit which operates to ensure compliance with
clause 19, the relevant test is repeated with a single
fault simulated, as indicated in a) to g) of 19.11.2
19.11.4 Appliances having a device with an off position P
obtained by electronic disconnection, or
a device that can be placed in the stand-by mode, P
subjected to the tests of 19.11.4.1 to 19.11.4.7 P
Appliances incorporating a protective electronic N/A
circuit subjected to the tests of 19.11.4.1 to 19.11.4.7,
except that
appliances operated for 30 s or 5 min during the test N/A
of 19.7 are not subjected to the tests for
electromagnetic phenomena.
Surge protective devices disconnected, unless N/A
They incorporate spark gaps N/A

TRF No. IEC60335_2_6J


Page 32 of 118 Report No:247713

IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict

During the test of the stand-by-mode, a suitable N/A


vessel is placed on the cooking zone if a pan
detector is incorporate. (IEC 60335-2-6:2002)
19.11.4.1 The appliance is subjected to electrostatic discharges P
in accordance with IEC 61000-4-2, test level 4
19.11.4.2 The appliance is subjected to radiated fields in P
accordance with IEC 61000-4-3, test level 3
19.11.4.3 The appliance is subjected to fast transient bursts in P
accordance with IEC 61000-4-4, test level 3 or 4 as
specified
19.11.4.4 The power supply terminals of the appliance P
subjected to voltage surges in accordance with IEC
61000-4-5, test level 3 or 4 as specified
Earthed heating elements in class I appliances P
disconnected
19.11.4.5 The appliance is subjected to injected currents in P
accordance with IEC 61000-4-6, test level 3
19.11.4.6 The appliance is subjected to the Class 3 voltage P
dips and interruptions in accordance with IEC 61000-
4-11
19.11.4.7 The appliance is subjected to mains signals in P
accordance with IEC 61000-4-13, test level class 2
19.11.4.8 The appliance is supplied at rated voltage and P
operated under normal operation. After 60s the
power supply is reduces to a level such that the
appliance ceases to respond or a programmable
component cease to operate.
The appliance continues to operate normally or P
requires a manual operation to restart
19.12 If the safety of the appliance for any of the fault N/A
conditions specified in 19.11.2 depends on the
operation of a miniature fuse-link complying with
IEC 60127, the test is repeated, measuring the
current flowing through the fuse-link; measured
current (A); rated current of the fuse-link (A) ........... :
19.13 During the tests the appliance does not emit flames, P
molten metal, poisonous or ignitable gas in
hazardous amounts
Temperature rises not exceeding the values shown (see appended table) P
in table 9
Enclosures not deformed to such an extent that P
compliance with cl. 8 is impaired
If the appliance can still be operated it complies with P
20.2

TRF No. IEC60335_2_6J


Page 33 of 118 Report No:247713

IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict

Insulation, other than of class III appliance, withstand the electric strength test of 16.3, -
the test voltage specified in table 4:
- basic insulation....................................................... : 1000V P
- supplementary insulation ....................................... : N/A
- reinforced insulation ............................................... : 3000V P
After operation or interruption of a control, clearances P
and creepage distances across the functional
insulation withstanding the electric strength test of
16.3. the test voltage being twice the working voltage
The appliance does not undergo a dangerous P
malfunction, and
no failure of protective electronic circuits, if the N/A
appliance is still operable
Appliances tested with an electronic switch in the off position, or in the stand-by mode: -
- do not become operational, or P
- if they become operational, do not result in a P
dangerous malfunction during or after the tests of
19.11.4
If the appliance contains lids or doors that are controlled by one or more interlocks, -
one of the interlocks may be released provided that:
- the lid or door does not move automatically to an N/A
open position when the interlock is released, and
- the appliance does not start after the cycle in N/A
which the interlock was released
Ovens: temperature in the centre of the oven not N/A
exceed 425C before opening (IEC 60335-2-
6:2002)
Temperature rise of the windings of induction hob N/A
elements and induction wok elements not exceed
the values specified in 19.7 (IEC 60335-2-6:2002)
Electric strength test of induction hob elements and N/A
induction wok elements is carried out immediately
after switching of the appliance (IEC 60335-2-
6:2002)
Glass in oven doors shall not be damaged N/A
(60335-2-6)
19.14 Appliances operated under the conditions of Clause Thermostats integrated in the P
11. Contactors or relays contacts operating under the heating elements operated
conditions of clause 11 short-circuited
19.15 For appliances with a mains voltage selector switch, N/A
the switch is set to the lowest rated voltage position
and the highest value of rated voltage is applied

TRF No. IEC60335_2_6J


Page 34 of 118 Report No:247713

IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict

19.101 Induction hob elements: test conditions according to N/A


the standard; diameter of the disc (cm) (IEC
60335-2-6)
19.102 Induction hob element and induction wok elements N/A
operated under normal operation at rated voltage
but with thermal controls short-circuited. (IEC
60335-2-6:2002)
Temperature rise of the oil not exceed 270 K : N/A
(IEC 60335-2-6:2002)

20 STABILITY AND MECHANICAL HAZARDS


20.1 Adequate stability Built-in appliance N/A
Tilting test through an angle of 10 (appliance placed N/A
on an inclined plane/horizontal plane); appliance
does not overturn
Tilting test repeated on appliances with heating N/A
elements, angle of inclination increased to 15
Possible heating test in overturned position; N/A
temperature rise does not exceed values shown in
table 9
20.2 Moving parts adequately arranged or enclosed as to No moving part N/A
provide protection against personal injury
Protective enclosures, guards and similar parts are N/A
non-detachable
Adequate mechanical strength and fixing of N/A
protective enclosures
Self-resetting thermal cut-outs and overcurrent N/A
protective devices not causing a hazard, by
unexpected reclosure
Not possible to touch dangerous moving parts with N/A
test probe
20.101 Cooking range and ovens shall have adequate stability when the open the door is -
subjected to a load (IEC 60335-2-6:2002)
Appliance subjected to a load test and by the test of N/A
20.102 if relevant : mass (kg) :
Cooking ranges are tested without fitting any N/A
stabilizing means that are specified in the
instructions of installation.
Cooking range incorporating a storage N/A
compartment adjacent to the oven and which the
shelves are pulled out simultaneously:
Shelve subjected to a load test : mass (g)
The appliance shall not tilt N/A
Damage and deformation of doors are ignored

TRF No. IEC60335_2_6J


Page 35 of 118 Report No:247713

IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict

20.102 For cooking ranges normally placed on the floor and with horizontally hinged oven -
doors with a hinge height of less than 430mm from the floor, the test of 20.101 is
repeated except that: (IEC 60335-2-6:2002)
-The cooking range is fitted with the stabilizing N/A
means, if any, specified in the instructions for
installation
-The mass of the load on the oven doors is N/A
increased to 50kg, or the mass of 22,5kg is placed
at the centre of the outer edge of the oven door,
whichever gives the most unfavourable results
The appliance shall not tilt N/A
Damage and deformation of doors are ignored

21 MECHANICAL STRENGTH
21.1 Appliance has adequate mechanical strength and is P
constructed as to withstand rough handling
Checked by applying blows to the appliance in P
accordance with test Ehb of IEC 60068-2-75, spring
hammer test, impact energy 0,5 J
If necessary, supplementary or reinforced insulation N/A
subjected to the electric strength test of 16.3
If necessary, repetition of groups of three blows on a N/A
new sample
Additional blows applied to the centre of glass doors N/A
(IEC 60335-2-6:2002)
The glass shall not fracture (IEC 60335-2-6:2002) N/A
Appliance incorporating visibly glowing heating elements enclosed in glass tubes, -
the blows are applied to the tubes as mounted in the appliance if they are : (IEC
60335-2-6:2002)
-located at the top of the oven and accessible to N/A
test probe 41 of IEC 61032
-located elsewhere in the oven and accessible to N/A
test probe B of IEC 61032
Hob surfaces of glass-ceramic or similar material: P
three blows applied on surfaces not exposed during
test of 21.102; impact energy 0,7  0,05 J
(IEC 60335-2-6:2002)
Temperature-sensing probe subjected to one cycle N/A
of test according to 15.101 and 16.2
(IEC 60335-2-6:2002)
21.2 Accessible parts of solid insulation having strength to Cover of supply terminal P
prevent penetration by sharp implements
The insulation is tested as specified, unless N/A
the thickness of supplementary insulation is at least 1 P
mm and reinforced insulation is at least 2 mm

TRF No. IEC60335_2_6J


Page 36 of 118 Report No:247713

IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict

21.101 Oven shelves and their supports shall have N/A


adequate mechanical strength (IEC 60335-2-
6:2002)
Total mass (kg) of the vessel, 220 times the volume N/A
of the useful oven space in m³, or 24kg, whichever
is less:
After the test the shelf and supports shall show no N/A
distortion impairing their further and
the shelf shall not fall from the supports N/A
Ovens with shelves that can be withdrawn and with N/A
stops: force of 80N, vessel with side dimensions
200mm
The shelf shall not tilt downwards by more than 6° N/A
21.102 Hob surfaces of glass-ceramic and similar materials P
shall withstand the stresses liable to occur in normal
use (IEC 60335-2-6:2002)
After the test, the hob surface not crack and the P
appliance withstand the electric strength test of 16.3
21.103 Temperature-sensing probes shall be constructed N/A
so that they are not damaged when trapped in the
oven door (IEC 60335-2-6:2002)
After the test, the probe then complies with 8.1, N/A
15.101 and Cl. 29
21.104 Glass panels of horizontally hinged oven doors shall N/A
withstand the thermal shock liable to occur in
normal use (IEC 60335-2-6:2002)
After the test, the glass shall not fracture N/A

22 CONSTRUCTION
22.1 Appliance marked with the first numeral of the IP N/A
system, relevant requirements of IEC 60529 are
fulfilled
22.2 Stationary appliance: means to provide all-pole disconnection from the supply -
provided, the following means being available:
- a supply cord fitted with a plug N/A
- a switch complying with 24.3 N/A
- a statement in the instruction sheet that a P
disconnection incorporated in the fixed wiring is to be
provided
- an appliance inlet N/A
Singe-pole switches and single-pole protective N/A
devices for the disconnection of heating elements in
single-phase, permanently connected class 01 and
class I appliances, connected to the phase conductor
22.3 Appliance provided with pins: no undue strain on N/A
socket-outlets

TRF No. IEC60335_2_6J


Page 37 of 118 Report No:247713

IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict

Applied torque not exceeding 0.25 Nm N/A


Pull force of 50N to each pin after the appliance has N/A
being placed in the heating cabinet; when cooled to
room temperature the pins are not displaced by more
than 1mm
Each pin subjected to a torque of 0.4Nm; the pins are N/A
not rotating unless rotating does not impair
compliance with the standard
22.4 Appliance for heating liquids and appliance causing Built-in hobs N/A
undue vibration not provided with pins for insertion
into socket-outlets
22.5 No risk of electric shock when touching the pins of 100nF only N/A
the plug, for appliances having a capacitor with rated
capacitance exceeding 0,1F, the appliance being
disconnected from the supply at the instant of voltage
peak
22.6 Electrical insulation not affected by condensing P
water or leaking liquid
Electrical insulation of Class II appliances not affected N/A
in case of a hose rupture or seal leak
22.7 Adequate safeguards against the risk of excessive N/A
pressure in appliances provided with steam-
producing devices
22.8 Electrical connections not subject to pulling during P
cleaning of compartments to which access can be
gained without the aid of a tool, and that are likely to
be cleaned in normal use
22.9 Insulation, internal wiring, windings, commutators and P
slip rings not exposed to oil, grease or similar
substances
Adequate insulating properties of oil or grease to N/A
which insulation is exposed
22.10 Not possible to reset voltage-maintained non-self- N/A
resetting thermal cut-outs by the operation of an
automatic switching device incorporated within the
appliance
Non-self-resetting thermal motor protectors have a N/A
trip-free action, unless
they are voltage maintained N/A
Location or protection of reset buttons of non-self- N/A
resetting controls is so that accidental resetting is
unlikely
22.11 Reliable fixing of non-detachable parts that provide P
the necessary degree of protection against electric
shock, moisture or contact with moving parts

TRF No. IEC60335_2_6J


Page 38 of 118 Report No:247713

IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict

Obvious locked position of snap-in devices used for P


fixing such parts
No deterioration of the fixing properties of snap-in P
devices used in parts that are likely to be removed
during installation or servicing
Tests as described P
22.12 Handles, knobs etc. fixed in a reliable manner P
Fixing in wrong position of handles, knobs etc. P
indicating position of switches or similar components
not possible
Axial force 15 N applied to parts, the shape being so For all model except with E P
that an axial pull is unlikely to be applied (electronic touch control)
Axial force 30 N applied to parts, the shape being so N/A
that an axial pull is likely to be applied
22.13 Unlikely that handles, when gripped as in normal use, N/A
make the operators hand touch parts having a
temperature rise exceeding the value specified for
handles which are held for short periods only
22.14 No ragged or sharp edges creating a hazard for the P
user in normal use, or during user maintenance
No exposed pointed ends of self-tapping screws etc., P
liable to be touched by the user in normal use or
during user maintenance
22.15 Storage hooks and the like for flexible cords smooth N/A
and well rounded
22.16 Automatic cord reels cause no undue abrasion or N/A
damage to the sheath of the flexible cord, no
breakage of conductors strands, no undue wear of
contacts
Cord reel tested with 6000 operations, as specified N/A
Electric strength test of 16.3, voltage of 1000 V N/A
applied
22.17 Spacers not removable from the outside by hand or N/A
by means of a screwdriver or a spanner
22.18 Current-carrying parts and other metal parts resistant P
to corrosion under normal conditions of use
22.19 Driving belts not used as electrical insulation N/A
22.20 Direct contact between live parts and thermal P
insulation effectively prevented, unless material used
is non-corrosive, non-hygroscopic and non-
combustible
Compliance is checked by inspection and, if N/A
necessary, by appropriate test

TRF No. IEC60335_2_6J


Page 39 of 118 Report No:247713

IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict

22.21 Wood, cotton, silk, ordinary paper and fibrous or Such material not used N/A
hygroscopic material not used as insulation, unless
impregnated
Magnesium oxide and mineral ceramic fibres are N/A
not considered as hygroscopic materials
(60335-2-6)
22.22 Appliances not containing asbestos P
22.23 Oils containing polychlorinated biphenyl (PCB) not P
used
22.24 Bare heating elements adequately supported P
In case of rupture, the heating conductor is unlikely to P
come in contact with accessible metal parts
22.25 Sagging heating conductors cannot come into contact N/A
with accessible metal parts
22.26 The insulation between parts operating at safety N/A
extra-low voltage and other live parts complies with
the requirements for double or reinforced insulation
22.27 Parts connected by protective impedance separated N/A
by double or reinforced insulation
22.28 Metal parts of Class II appliances conductively N/A
connected to gas pipes or in contact with water:
separated from live parts by double or reinforced
insulation
22.29 Class II appliances permanently connected to fixed N/A
wiring so constructed that the required degree of
access to live parts is maintained after installation
22.30 Parts serving as supplementary or reinforced P
insulation fixed so that they cannot be removed
without being seriously damaged, or
so constructed that they cannot be replaced in an N/A
incorrect position, and so that if they are omitted, the
appliance is rendered inoperable or manifestly
incomplete
22.31 Clearances and creepage distances over P
supplementary and reinforced insulation not reduced
below values specified in clause 29 as a result of
wear
Clearances and creepage distances between live P
parts and accessible parts not reduced below values
for supplementary insulation, if wires, screws etc.
become loose
22.32 Supplementary and reinforced insulation designed or P
protected against deposition of dirt or dust

TRF No. IEC60335_2_6J


Page 40 of 118 Report No:247713

IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict

Supplementary insulation of natural or synthetic N/A


rubber resistant to ageing, or arranged and
dimensioned so that creepage distances are not
reduced below values specified in 29.2
Ceramic material not tightly sintered, similar material N/A
or beads alone not used as supplementary or
reinforced insulation
Oxygen bomb test at 70 C for 96 h and 16 h at room N/A
temperature
Insulating material in which heating conductors are N/A
embedded is considered to be basic insulation and
not reinforced insulation
22.33 Conductive liquids that are or may become N/A
accessible in normal use are not in direct contact with
live parts
Electrodes not used for heating liquids N/A
For class II constructions, conductive liquids that are Electric hobs, conductive N/A
or may become accessible in normal use, not in liquids in users’ vessels only.
direct contact with basic or reinforced insulation
For class II constructions, conductive liquids which N/A
are in contact with live parts, not in direct contact with
reinforced insulation
22.34 Shafts of operating knobs, handles, levers etc. not N/A
live, unless the shaft is not accessible when the part
is removed
22.35 Handles, levers and knobs, held or actuated in P
normal use, not becoming live in the event of a failure
of basic insulation
Such parts being of metal, and their shafts or fixings N/A
are likely to become live in the event of a failure of
basic insulation, are either adequately covered by
insulation material or their accessible parts are
separated from their shafts or fixings by
supplementary insulation
This requirement does not apply to handles, levers N/A
and knobs on stationary appliances other than those
of electrical components, provided they are either
reliably connected to an earthing terminal or earthing
contact, or separated from live parts by earthed metal
22.36 Handles continuously held in the hand in normal use N/A
are so constructed that when gripped as in normal
use, the operators hand is not likely to touch metal
parts, unless they are separated from live parts by
double or reinforced insulation
22.37 Capacitors in Class II appliances not connected to N/A
accessible metal parts, unless complying with 22.42

TRF No. IEC60335_2_6J


Page 41 of 118 Report No:247713

IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict

Metal casings of capacitors in Class II appliances N/A


separated from accessible metal parts by
supplementary insulation, unless complying with
22.42
22.38 Capacitors not connected between the contacts of a P
thermal cut-out
22.39 Lamp holders used only for the connection of lamps N/A
22.40 Motor-operated appliances and combined appliances N/A
intended to be moved while in operation, or having
accessible moving parts, fitted with a switch to control
the motor. The actuating member of the switch being
easily visible and accessible
Unless the appliance can operate continuously, N/A
automatically or remotely without giving rise to a
hazard, appliances for remote operation being fitted
with a switch. The actuating member of the switch
being easily visible and accessible.
22.41 No components, other than lamps, containing P
mercury
22.42 Protective impedance consisting of at least two N/A
separate components
Values specified in 8.1.4 not exceeded if any one of N/A
the components are short-circuited or open-circuited
22.43 Appliances adjustable for different voltages, N/A
accidental changing of the setting of the voltage
unlikely to occur
22.44 Appliances shall not have an enclosure that is shaped P
or decorated like a toy
22.45 When air is used as reinforced insulation, clearances P
not reduced below the values specified in 29.1.4 due
to deformation as a result of an external force applied
to the enclosure
22.46 Software used in protective electronic circuits is N/A
software class B or C .............................................. :
22.47 Appliances connected to the water mains withstand N/A
the water pressure expected in normal use
No leakage from any part, including any inlet water N/A
hose
22.48 Appliances connected to the water mains constructed N/A
to prevent backsiphonage of non-potable water
22.49 For remote operation, the duration of operation shall N/A
be set before the appliance can be started, unless
the appliance switches off automatically or can N/A
operate continuously without hazard

TRF No. IEC60335_2_6J


Page 42 of 118 Report No:247713

IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict

22.50 Controls incorporated in the appliance take priority N/A


over controls actuated by remote operation
22.51 A control on the appliance being manually adjusted to N/A
the setting for remote operation before the appliance
can be operated in this mode
There is a visual indication showing that the appliance N/A
is adjusted for remote operation
Manual setting and visual indication not necessary on appliances that can operate as -
follows, without giving rise to a hazard:
- operate continuously, N/A
- operate automatically, or N/A
- be operated remotely N/A
It is not necessary to manually adjust to the setting for N/A
remote operation in order to switch the appliance off.
(IEC 60335-2-6)
22.52 Socket-outlets on appliances accessible to the user in N/A
accordance with the socket-outlet system used in the
country in which the appliance is sold
22.101 Hob element prevented from rotating about vertical P
axis and (IEC 60335-2-6:2002)
adequately supported in all positions of adjustment P
of their supports (IEC 60335-2-6:2002)
Hobs constructed so that damage to is unlikely N/A
occur while the hob elements are being removed or
replaced, for hobs with detachable hob elements
(IEC 60335-2-6:2002)
22.102 Timers intended to delay the operation of a heating N/A
element shall not control a radiant grill, unless
(IEC 60335-2-6:2002)
the grill is thermally controlled and incorporated in N/A
an oven or other compartment
(IEC 60335-2-6:2002)
22.103 Ovens vents shall be constructed so that any N/A
moisture or grease discharged through them cannot
affect clearances and creepage distances between
live parts and other parts of the appliance
(IEC 60335-2-6:2002)
22.104 Steam ovens shall be constructed so that steam N/A
vents and ducts are unlikely to become blocked
during normal use (IEC 60335-2-6:2002)
22.105 Built-in ovens shall only be vented through the front, N/A
unless (IEC 60335-2-6:2002)
provision is made for venting through a duct N/A
(IEC 60335-2-6:2002)
22.106 Grills shall be constructed so that grill can be easily N/A
positioned without jamming (IEC 60335-2-6:2002)
The grills pans shall not fall from the support when N/A
moved sideways (IEC 60335-2-6:2002)

TRF No. IEC60335_2_6J


Page 43 of 118 Report No:247713

IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict

22.107 Pyrolytic self-cleaning ovens shall switch off N/A


automatically at the end of the process and require
a manual operation to start another cleaning cycle
(IEC 60335-2-6:2002)
22.108 Pyrolytic self-cleaning ovens shall be constructed so N/A
that opening and closing of the door does not impair
the interlock system or damage the door seal; test
as specified (IEC 60335-2-6:2002)
After the test, the interlock system shall be fit for N/A
further use and the door seal shall not be damage
(IEC 60335-2-6:2002)
22.109 Pyrolytic self-cleaning ovens shall incorporate an N/A
interlock so that access to the oven cannot be
gained when the temperature in the centre of the
oven exceeds 350 C. even if the interlock is
defective; test as specified (IEC 60335-2-6:2002)
22.110 Pyrolytic self-cleaning ovens shall be constructed so N/A
that ignitable gases cannot be discharged through
vents during the cleaning process; test as specified
(IEC 60335-2-6:2002)
22.111 Pyrolytic self-cleaning ovens: no risk of emission of N/A
flames; test as specified (60335-2-6)
22.112 Hobs shall be constructed so that hinged lids cannot N/A
close accidentally (IEC 60335-2-6:2002)
22.113 Hobs shall be constructed so that inadvertent P
operation of touch controls due to spillage of liquid
or damp cloth is unlikely; test as specified
(IEC 60335-2-6:2002)
22.114 Hobs having touch controls shall require at least two P
manual operations to switch on a hob element but
only one to switch off (IEC 60335-2-6:2002)
Additional hob elements may be switched on by N/A
single manual operation (IEC 60335-2-6:2002)
Hobs having touch controls shall incorporate visual P
means to indicate when each hob is energized
(IEC 60335-2-6:2002)
22.115 Induction hob elements and induction wok N/A
elements, and other hob elements incorporating a
pan detector shall be constructed so that the hob
element operated can only be operated when a
vessel is placed on the cooking zone
(IEC 60335-2-6:2002)
Appliance operated at rated voltage: (IEC 60335-2- N/A
6:2002)
Temperature rise not exceed 35 K, for induction hob N/A
elements and induction wok elements : (IEC 60335-
2-6:2002)
Other hobs elements shall not operate N/A
(IEC 60335-2-6:2002)
22.116 Hob elements incorporating a pan detector shall be N/A
constructed so that the hob element is not switched
on by the vessel if it has been removed for more
than 10 min (IEC 60335-2-6:2002)

TRF No. IEC60335_2_6J


Page 44 of 118 Report No:247713

IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict

22.117 Appliances incorporating a pan detector a signal N/A


lamp shall indicate when the control for the hob
elements is not switched to the off position
(IEC 60335-2-6:2002)
22.118 If a plug of a supply cord is engaged in a N/A
socket-outlet located directly above the door, it shall
not be possible to operate a grill
(IEC 60335-2-6:2002)
22.119 Cooking ranges incorporating a retractable deflector N/A
to prevent excessive temperatures on control knobs
shall be constructed so that the user is unlikely to
touch hot surfaces of the deflector when operating
the controls (IEC 60335-2-6:2002)
22.120 Outer glass panels of oven doors shall be made N/A
from glass that breaks into small pieces when it
fractures (IEC 60335-2-6:2002)
22.121 Outer glass panels of oven doors that are intended N/A
to be removed by the user for cleaning shall be
constructed so that they cannot be fixed in an
incorrect orientation (IEC 60335-2-6:2002)
22.122 Ovens with shelves that can be withdrawn shall be N/A
fitted with rest positions (IEC 60335-2-6:2002)
The shelves shall also be constructed to prevent N/A
cooking dishes, or the like, from sliding over the rear
edge (IEC 60335-2-6:2002)

23 INTERNAL WIRING
23.1 Wireways smooth and free from sharp edges P
Wires protected against contact with burrs, cooling P
fins etc.
Wire holes in metal well rounded or provided with P
bushings
Wiring effectively prevented from coming into contact N/A
with moving parts
23.2 Beads etc. on live wires cannot change their position, N/A
and are not resting on sharp edges or corners
Beads inside flexible metal conduits contained within N/A
an insulating sleeve
23.3 Electrical connections and internal conductors N/A
movable relatively to each other not exposed to
undue stress
Flexible metallic tubes not causing damage to N/A
insulation of conductors
Open-coil springs not used N/A
Adequate insulating lining provided inside a coiled N/A
spring, the turns of which touch one another

TRF No. IEC60335_2_6J


Page 45 of 118 Report No:247713

IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict

No damage after 10 000 flexings for conductors N/A


flexed during normal use or 100 flexings for
conductors flexed during user maintenance
Electric strength test of 16.3, 1000 V between live N/A
parts and accessible metal parts
Not more than 10% of the strands of any conductor N/A
broken, and
not more than 30% for wiring supplying circuits that N/A
consume no more than 15W
The requirement also applies if parts of a cooking N/A
range are folded onto the hob surface or separated
from their normal position, for transportation
purposes (IEC 60335-2-6:2002)
23.4 Bare internal wiring sufficiently rigid and fixed N/A
23.5 The insulation of internal wiring withstanding the P
electrical stress likely to occur in normal use
No breakdown when a voltage of 2000 V is applied P
for 15 min between the conductor and metal foil
wrapped around the insulation
23.6 Sleeving used as supplementary insulation on N/A
internal wiring retained in position by clamping at
both ends, or
be such that it can only be removed by breaking or N/A
cutting
23.7 The colour combination green/yellow used only for P
earthing conductors
23.8 Aluminium wires not used for internal wiring P
23.9 No lead-tin soldering of stranded conductors where P
they are subject to contact pressure, unless
clamping means so constructed that there is no risk N/A
of bad contact due to cold flow of the solder
23.10 The insulation and sheath of internal wiring, N/A
incorporated in external hoses for the connection of
an appliance to the water mains, at least equivalent to
that of light polyvinyl chloride sheathed flexible cord
(60227 IEC 52)

24 COMPONENTS
24.1 Components comply with safety requirements in P
relevant IEC standards
List of components (see appended table) P

TRF No. IEC60335_2_6J


Page 46 of 118 Report No:247713

IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict

Components not tested and found to comply with P


relevant IEC standard for the number of cycles
specified are tested in accordance with 24.1.1 to
24.1.9
Components not tested and found to comply with P
relevant IEC standard, components not marked or
not used in accordance with its marking, tested under
the conditions occurring in the appliance
Lampholders and starterholders not being tested and N/A
found to comply with the relevant IEC standard,
tested as a part of the appliance and additionally
according to the gauging and interchangeability
requirements of the relevant IEC standard
24.1.1 Capacitors likely to be permanently subjected to the P
supply voltage and used for radio interference
suppression or for voltage dividing, complying with
IEC 60384-14, or
tested according to annex F N/A
24.1.2 Safety isolating transformers complying with IEC N/A
61558-2-6, or
tested according to annex G N/A
24.1.3 Switches complying with IEC 61058-1, the number of P
cycles of operation being at least 10 000, or
tested according to annex H N/A
If the switch operates a relay or contactor, the N/A
complete switching system is subjected to the test
Switches controlling hob elements subjected to P
30 000 cycles of operation (IEC 60335-2-6:2002)
24.1.4 Automatic controls complying with IEC 60730-1 with relevant part 2. The number of -
cycles of operation being:
- thermostats: 10 000 Separate approved P
- temperature limiters: 1 000 N/A
- self-resetting thermal cut-outs: 300 N/A
- self-resetting thermal cut-outs for heating 100 000 N/A
elements of glass-ceramic hobs (IEC
60335-2-6:2002)
- self-resetting thermal cut-outs for heating 10 000 N/A
elements of other hobs
(IEC 60335-2-6:2002)
- voltage maintained non-self-resetting 1000 N/A
thermal cut-outs:
- other non-self-resetting thermal cut-outs: 30 N/A
- timers: 3 000 N/A

TRF No. IEC60335_2_6J


Page 47 of 118 Report No:247713

IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict

- energy regulators for automatic action 100 000 N/A


(IEC 60335-2-6:2002)
- energy regulators for manual action (IEC 10 000 N/A
60335-2-6:2002)
thermostats controlling the cleaning 3 000 N/A
process in pyrolytic self-cleanings ovens
(IEC 60335-2-6:2002)
Thermal motor protectors are tested in combination N/A
with their motor under the conditions specified in
Annex D
For water valves containing live parts and that are N/A
incorporated in external hoses for connection of an
appliance to the water mains, the degree of protection
declared for subclause 6.5.2 of IEC 60730-2-8 is
IPX7
24.1.5 Appliance couplers complying with IEC 60320-1 N/A
However, appliances classified higher than IPX0, the N/A
appliance couplers complying with IEC 60320-2-3
Interconnection couplers complying with IEC 60320- N/A
2-2
24.1.6 Small lamp holders similar to E10 lampholders N/A
complying with IEC 60238, the requirements for E10
lampholders being applicable
24.1.7 If the remote operation of the appliance is via a N/A
telecommunication network, the relevant standard for
the telecommunication interface circuitry in the
appliance is IEC 62151
24.1.8 The relevant standard for thermal links is IEC 60691. N/A
Thermal links not complying with IEC 60691 are
considered to be an intentionally weak part for the
purposes of Clause 19
24.1.9 Relays, other than motor starting relays, tested as P
part of the appliance
They are also tested in accordance with Clause 17 of 10 000 P
IEC 60730-1, the number of operations in 24.1.4
selected according to the relay function in the
appliance.................................................................. :
24.2 No switches or automatic controls in flexible cords P
No devices causing the protective device in the fixed P
wiring to operate in the event of a fault in the
appliance
No thermal cut-outs that can be reset by soldering N/A
unless
the solder has a melding point of at least 230 ˚C N/A

TRF No. IEC60335_2_6J


Page 48 of 118 Report No:247713

IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict

24.3 Switches intended for all-pole disconnection of N/A


stationary appliances are directly connected to the
supply terminals and having a contact separation in
all poles, providing full disconnection under
overvoltage category III conditions
24.4 Plugs and socket-outlets for extra-low voltage circuits N/A
and heating elements, not interchangeable with plugs
and socket-outlets listed in IEC 60083 or IEC 60906-
1 or with connectors and appliance inlets complying
with the standard sheets of IEC 60320-1
24.5 Capacitors in auxiliary windings of motors marked N/A
with their rated voltage and capacitance and used
accordingly
Voltage across capacitors in series with a motor N/A
winding does not exceed 1,1 times rated voltage,
when the appliance is supplied at 1,1 times rated
voltage under minimum load
24.6 Working voltage of motors connected to the supply N/A
mains and having basic insulation that is inadequate
for the rated voltage of the appliance, not exceeding
42V
In addition, the motors are complying with the N/A
requirements of Annex I
24.7 Detachable hose-sets for connection of appliances N/A
to the water mains comply with IEC 61770
They are supplied with the appliance N/A
Appliances intended to be permanently connected N/A
to the water mains not connected by a detachable
hose-set
24.8 Motor running capacitors in appliances for which N/A
30.2.3 is applicable and that are permanently
connected in series with a motor winding, not
causing a hazard in event of a failure
One or more of the following conditions are to be met: N/A
- the capacitors are of class P2 according to IEC N/A
60252-1
- the capacitors are housed within a metallic or N/A
ceramic enclosure
- the distance of separation of the outer surface to N/A
adjacent non-metallic parts exceeds 50 mm
- adjacent non-metallic parts within 50 mm N/A
withstand the needle-flame test of Annex E
- adjacent non-metallic parts within 50 mm classified N/A
as at least V-1 according to IEC 60695-11-10

TRF No. IEC60335_2_6J


Page 49 of 118 Report No:247713

IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict

24.101 Thermostat and energy regulators incorporating an For model type “R”, “M” only. P
off position shall not switch on a result of variations
in ambient temperatures (IEC 60335-2-6:2002)
During the test, the off position shall be maintained P
No breakdown shall occur; test voltage 500 V P
24.102 Incorporated socket-outlets in cooking ranges: N/A
single-phase type, earthing contact, rated current
16 A, protected by fuses or circuit breaker placed
behind a non-detachable cover rated current not
exceeding rated current of the socket-outlet
(IEC 60335-2-6:2002)
Cooking range for permanently connected to fixed N/A
wiring or is fitted with a polarized plug, the neutral
pole need not be protected (IEC 60335-2-6:2002)
If fuses become accessible after opening a drawer N/A
or other compartment, a non-detachable cover is
not required (IEC 60335-2-6:2002)

25 SUPPLY CONNECTION AND EXTERNAL FLEXIBLE CORDS


25.1 Appliance not intended for permanent connection to fixed wiring, means for connection -
to the supply:
- supply cord fitted with a plug N/A
- an appliance inlet having at least the same degree N/A
of protection against moisture as required for the
appliance
- pins for insertion into socket-outlets N/A
25.2 Appliance not provided with more than one means of P
connection to the supply mains
Stationary appliance for multiple supply may be N/A
provided with more than one means of connection,
provided electric strength test of 1250 V for 1 min
between each means of connection causes no
breakdown
25.3 Appliance intended to be permanently connected to P
fixed wiring provided with one of the following
means for connection to the supply mains:
- a set of terminals allowing the connection of a P
flexible cord
- a fitted supply cord P
- a set of supply leads accommodated in a suitable N/A
compartment
- a set of terminals for the connection of cables of N/A
fixed wiring, cross-sectional areas specified in 26.6,
and the appliance allows the connection of the
supply conductors after the appliance has been
fixed to its support

TRF No. IEC60335_2_6J


Page 50 of 118 Report No:247713

IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict

- a set of terminals and cable entries, conduit N/A


entries, knock-outs or glands, allowing connection
of appropriate types of cable or conduit, and the
appliance allows the connection of the supply
conductors after the appliance has been fixed to its
support
For a fixed appliance constructed so that parts can N/A
be removed to facilitate easy installation, this
requirement is met if it is possible to connect the
fixed wiring without difficulty after a part of the
appliance has been fixed to its support
Connection of supply wires of hobs, built-in ranges P
and built-in ovens may be made before the
appliance is installed (IEC 60335-2-6:2002)
25.4 Cable and conduit entries, rated current of appliance N/A
not exceeding 16 A, dimension according to table 10
Introduction of conduit or cable does not reduce N/A
clearances or creepage distances below values
specified in 29
25.5 Method for assemble supply cord with the appliance: -
- type X attachment P
- type Y attachment N/A
- type Z attachment, if allowed in part 2 N/A
Type X attachment, other than those with a specially P
prepared cord, not used for flat twin tinsel cords
For multi-phase appliances supplied with a supply N/A
cord and that are intended to be permanently
connected to fixed wiring, the supply cord is
assembled to the appliance by type Y attachment
25.6 Plugs fitted with only one flexible cord N/A
25.7 Supply cords being one of the following types: -
- rubber sheathed (at least 60245 IEC 53) H05RR-F P
H05BB-F
- polychloroprene sheathed (at least 60245 IEC 57) N/A
- cross-linked polyvinyl chloride sheathed (at least N/A
60245 IEC 87)
Polyvinyl chloride sheathed: -
Not used if they are likely to touch metal parts having a temperature rise exceeding
75K during the test of Clause 11.
- light polyvinyl chloride sheathed cord (at least 60227 N/A
IEC 52), appliances not exceeding 3 kg
- ordinary polyvinyl chloride sheathed cord (at least N/A
60227 IEC 53), other appliances

TRF No. IEC60335_2_6J


Page 51 of 118 Report No:247713

IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict

Heat resistant polyvinyl chloride sheathed: -


Not used for type X attachment other than specially prepared cords.
- Heat-resistant light polyvinyl chloride sheathed cord N/A
(at least 60227 IEC 56), appliances not exceeding
3 kg
- heat-resistant polyvinyl chloride sheathed cord N/A
(60227 IEC 57), other appliances
Supply cords for class III appliances adequately N/A
insulated
Test with 500 V for 2 min for supply cords of class N/A
III appliances that contain live parts
25.8 Nominal cross-sectional area of supply cords 4 heating elements sample: P
according to table 11; rated current (A); cross- Max rated current: 30.9A;
sectional area (mm²) ............................................... : (diversity factor F=0.675 taken
into account)
30.9Ax0.675=20.86A
2
Cross section: 2.5mm
3 Heating elements sample:
Max rated current: 24.59A;
2
Cross section: 2.5mm
25.9 Supply cord not in contact with sharp points or edges P
25.10 Green/yellow core for earthing purposes in Class I P
appliance
25.11 Conductors of supply cords not consolidated by lead- P
tin soldering where they are subject to contact
pressure, unless
clamping means so constructed that there is no risk N/A
of bad contacts due to cold flow of the solder
25.12 Moulding the cord to part of the enclosure does not N/A
damage the insulation of the supply cord
25.13 Inlet opening so shaped as to prevent damage to the P
supply cord
Unless the enclosure at the inlet opening is of Inlet opening is of insulating N/A
insulation material, a non-detachable lining or material
bushing complying with 29.3 for supplementary
insulation provided
If unsheathed supply cord, a similar additional N/A
bushing or lining is required, unless
the appliance is class 0, or N/A
a class III appliance not containing live parts N/A
25.14 Supply cords adequately protected against excessive N/A
flexing
Flexing test: N/A

TRF No. IEC60335_2_6J


Page 52 of 118 Report No:247713

IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict

- applied force (N) .................................................... : N/A


- number of flexings ................................................. : N/A
The test does not result in: N/A
- short circuit between the conductors N/A
- breakage of more than 10% of the strands of any N/A
conductor
- separation of the conductor from its terminal N/A
- loosening of any cord guard N/A
- damage, within the meaning of the standard, to the N/A
cord or the cord guard
- broken strands piercing the insulation and becoming N/A
accessible
For temperature-sensing probes, the total number N/A
of flexings is 5 000. (IEC 60335-2-6:2002)
Probes with circular section cords are turned N/A
through 90° after 2 500 flexings(IEC 60335-2-
6:2002)
25.15 Conductors of the supply cord relieved from strain, P
twisting and abrasion by use of cord anchorage
The cord cannot be pushed into the appliance to such P
an extent that the cord or internal parts of the
appliance can be damaged
Pull and torque test of supply cord, values shown in Pull: 100N P
table 10: pull (N); torque (not on automatic cord reel) Torque: 0.35Nm
(Nm) ......................................................................... :
Cord not damaged and max. 2 mm displacement of P
the cord
25.16 Cord anchorages for type X attachments constructed and located so that: -
- replacement of the cord is easily possible P
- it is clear how the relief from strain and the P
prevention of twisting are obtained
- they are suitable for different types of cord P
- cord cannot touch the clamping screws of cord P
anchorage if these screws are accessible, unless
separated from accessible metal parts by
supplementary insulation
- the cord is not clamped by a metal screw which P
bears directly on the cord
- at least one part of the cord anchorage securely P
fixed to the appliance, unless part of a specially
prepared cord

TRF No. IEC60335_2_6J


Page 53 of 118 Report No:247713

IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict

- screws which have to be operated when replacing P


the cord do not fix any other component, if applicable
- if labyrinths can be bypassed the test of 25.15 is N/A
nevertheless withstood
- for Class 0, 0I and I appliances: they are of P
insulating material or are provided with an insulating
lining, unless a failure of the insulation of the cord
does not make accessible metal parts live
- for Class II appliances: they are of insulating N/A
material, or if of metal, they are insulated from
accessible metal parts by supplementary insulation
After the test of 25.15, under the conditions P
specified, the conductors have not moved by more
than 1 mm in the terminals
25.17 Adequate cord anchorages for type Y and Z N/A
attachment
25.18 Cord anchorages only accessible with the aid of a N/A
tool, or
so constructed that the cord can only be fitted with the P
aid of a tool
25.19 Type X attachment, glands not used as cord N/A
anchorage in portable appliances
Tying the cord into a knot or tying the cord with string P
not used
25.20 Conductors of the supply cord for type Y and Z N/A
attachment adequately additionally insulated
25.21 Space for supply cord for type X attachment or for P
connection of fixed wiring constructed to permit
checking of conductors with respect to correct
positioning and connection before fitting any cover, no
risk of damage to the conductors when fitting the
cover, no contact with accessible metal parts if a
conductor becomes loose, etc.
For portable appliances, the uninsulated end of a N/A
conductor prevented from any contact with accessible
metal parts, unless the end of the cord is such that
the conductors are unlikely to slip free
25.22 Appliance inlet: -
- live parts not accessible during insertion or removal N/A
- connector can be inserted without difficulty N/A
- the appliance is not supported by the connector N/A

TRF No. IEC60335_2_6J


Page 54 of 118 Report No:247713

IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict

- is not for cold conditions if temp. rise of external N/A


metal parts exceeds 75 K, unless the supply cord is
not likely to touch such metal parts
25.23 Interconnection cords comply with the requirements N/A
for the supply cord, except as specified
If necessary, electric strength test of 16.3 N/A
25.24 Interconnection cords not detachable without the aid N/A
of a tool if compliance with the standard is impaired
when they are disconnected
25.25 Dimensions of pins compatible with the dimensions of N/A
the relevant socket-outlet. Dimensions of pins and
engagement face in accordance with the relevant
plug in IEC 60083

26 TERMINALS FOR EXTERNAL CONDUCTORS


26.1 Appliances provided with terminals or equally P
effective devices for connection of external
conductors
Terminals only accessible after removal of a non- P
detachable cover
for class III appliances that do not contain live parts N/A
Earthing terminals may be accessible if a tool is P
required to make the connections and means are
provided to clamp the wire independently from its
connection
26.2 Appliances with type X attachment and appliances for P
connection to fixed wiring provided with terminals in
which connections are made by means of screws,
nuts or similar devices, unless the connections are
soldered
Screws and nuts serve only to clamp supply P
conductors, except
internal conductors, if so arranged that they are N/A
unlikely to be displaced when fitting the supply
conductors
If soldered connections used, the conductor so N/A
positioned or fixed that reliance is not placed on
soldering alone, unless
barriers provided so that neither clearances nor N/A
creepage distances between live parts and other
metal parts reduced below the values for
supplementary insulation if the conductor becomes
free at the soldered joint

TRF No. IEC60335_2_6J


Page 55 of 118 Report No:247713

IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict

26.3 Terminals for type X attachment and for connection P


of cables of fixed wiring so constructed that the
conductor is clamped between metal surfaces with
sufficient contact pressure but without damaging the
conductor
Terminals fixed so that when the clamping means is tightened or loosened: -
- the terminal does not become loose P
- internal wiring is not subjected to stress P
- neither clearances nor creepage distances are P
reduced below the values in clause 29
Compliance checked by inspection and by the test Diameter of screws: 3,8mm P
of subclause 9.6 of IEC 60999-1, the torque applied Torque applied: 1,2Nm * 2/3 =
being equal to two-thirds of the torque specified 0,8Nm
(Nm) ...................................................................... :
26.4 Terminals for type X attachment, except those with a P
specially prepared cord, and those for connection to
fixed wiring, no special preparation of conductors
required, and so constructed or placed that
conductors prevented from slipping out
26.5 Terminals for type X attachment so located or P
shielded that if a wire of a stranded conductor
escapes, no risk of accidental connection to other
parts that result in a hazard
Stranded conductor test, 8 mm insulation removed P
No contact between live parts and accessible metal P
parts and, for class II constructions, between live
parts and metal parts separated from accessible
metal parts by supplementary insulation only
26.6 Terminals for type X attachment and for connection 2.5mm² and 4mm² P
to fixed wiring suitable for connection of conductors
with required cross-sectional area according to
table 13; rated current (A); nominal cross-sectional
area (mm²) ............................................................... :
Terminals only suitable for a specially prepared cord N/A
26.7 Terminals for type X attachment accessible after P
removal of a cover or part of the enclosure
26.8 Terminals for the connection to fixed wiring, including P
the earthing terminal, located close to each other
26.9 Terminals of the pillar type constructed and located P
as specified
26.10 Terminals with screw clamping and screwless N/A
terminals not used for flat twin tinsel cords, unless
conductors ends fitted with a device suitable for
screw terminals
Pull test of 5 N to the connection N/A

TRF No. IEC60335_2_6J


Page 56 of 118 Report No:247713

IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict

26.11 For type Y and Z attachment: soldered, welded, N/A


crimped and similar connections may be used
For Class II appliances: the conductor so positioned N/A
or fixed that reliance is not placed on soldering,
welding or crimping alone
If soldering, welding or crimping alone used, barriers N/A
provided so that clearances and creepage distances
between live parts and other metal parts are not
reduced below the values for supplementary
insulation if the conductor becomes free

27 PROVISION FOR EARTHING


27.1 Accessible metal parts of Class 0I and I appliances, P
permanently and reliably connected to an earthing
terminal or contact of the appliance inlet
Earthing terminals not connected to neutral terminal P
Class 0, II and III appliance have no provision for N/A
earthing
Safety extra-low voltage circuits not earthed, unless N/A
protective extra-low voltage circuits
27.2 Clamping means adequately secured against P
accidental loosening
Terminals used for the connection of external N/A
equipotential bonding conductors allow connection of
conductors of 2.5 to 6 mm², and
do not provide earthing continuity between different N/A
parts of the appliance
Conductors cannot be loosened without the aid of a N/A
tool
27.3 For detachable parts that are plugged into another N/A
part of the appliance, and having an earth connection,
the earth connection made before and separated
after current-carrying connections when removing the
part
For appliances with supply cord, current-carrying P
conductors become taut before earthing conductor, if
the cord slips out of the cord anchorage
27.4 No risk of corrosion resulting from contact between P
metal of earthing terminal and other metal
Adequate resistance to corrosion of coated or N/A
uncoated parts providing earthing continuity, other
than parts of a metal frame or enclosure

TRF No. IEC60335_2_6J


Page 57 of 118 Report No:247713

IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict

Parts of steel providing earthing continuity provided at N/A


the essential areas with an electroplated coating,
thickness at least 5 µm
Adequate protection against rusting of parts of coated P
or uncoated steel, only intended to provide or transmit
contact pressure
In case of aluminium alloys precautions taken to N/A
avoid risk of corrosion
27.5 Low resistance of connection between earthing P
terminal and earthed metal parts
This requirement does not apply to connections P
providing earthing continuity in the protective extra-
low voltage circuit, provided that clearances of basic
insulation are based on the rated voltage of the
appliance
Resistance not exceeding 0,1 Ω at the specified low- 0.05Ω P
resistance test
27.6 The printed conductors of printed circuit boards shall N/A
not be used to provide earthing continuity in hand-
held appliances.
They may be used to provide earthing continuity in N/A
other appliances if at least two tracks are used with
independent soldering points and the appliance
complies with 27.5 for each circuit

28 SCREWS AND CONNECTIONS


28.1 Fixings, electrical connections and connections P
providing earthing continuity withstand mechanical
stresses
Screws not of soft metal liable to creep, such as zinc P
or aluminium
Diameter of screws of insulating material min. 3 mm N/A
Screws of insulating material not used for any N/A
electrical connection or connections providing
earthing continuity
Screws used for electrical connections or connections P
providing earthing continuity screw into metal
Screws not of insulating material if their replacement N/A
by a metal screw can impair supplementary or
reinforced insulation
Type X attachment, screws to be removed for N/A
replacement of supply cord or for user maintenance,
not of insulating material if their replacement by a
metal screw can impair basic insulation

TRF No. IEC60335_2_6J


Page 58 of 118 Report No:247713

IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict

For screws and nuts; test as specified (see appended table) P


28.2 Electrical connections and connections providing P
earthing continuity constructed so that contact
pressure not transmitted through insulating material
liable to shrink or distort, unless shrinkage or
distortion compensated
This requirement does not apply to electrical connections in circuits of appliances for -
which:
 30.2.2 is applicable and that carry a current N/A
not exceeding 0,5 A
 30.2.3 is applicable and that carry a current N/A
not exceeding 0,2 A
28.3 Space-threaded (sheet metal) screws only used for N/A
electrical connections if they clamp the parts together
Thread-cutting (self-tapping) screws and thread N/A
rolling screws only used for electrical connections if
they generate a full form standard machine screw
thread
Thread-cutting (self-tapping) screws not used if they N/A
are likely to be operated by the user or installer
Thread-cutting, thread rolling and space threaded screws may be used in connections N/A
providing earthing continuity provided it is not necessary to disturb the connection:
- in normal use, N/A
- during user maintenance, N/A
- when replacing a supply cord having a type X N/A
attachment, or
- during installation N/A
At least two screws being used for each connection N/A
providing earthing continuity, unless
the screw forms a thread having a length of at least P
half the diameter of the screw
28.4 Screws and nuts that make mechanical connection P
secured against loosening if they also make
electrical connections or connections providing
earthing continuity
This requirement does not apply to screws in the N/A
earthing circuit if at least two screws are used, or
if an alternative earthing circuit is provided N/A
Rivets for electrical connections or connections N/A
providing earthing continuity secured against
loosening if the connections are subjected to torsion

TRF No. IEC60335_2_6J


Page 59 of 118 Report No:247713

IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict

29 CLEARANCES, CREEPAGE DISTANCES AND SOLID INSULATION


Clearances, creepage distances and solid insulation P
withstand electrical stress
For coatings used on printed circuits boards to N/A
protect the microenvironment (Type 1) or to provide
basic insulation (Type 2), annex J applies .............. :
The microenvironment is pollution degree 1 under N/A
Type 1 coating
For type 2 protection, the spacing between the N/A
conductors before the protection is applied is not
less than the values specified in Table 1 of IEC
60664-3
These values apply to functional, basic, N/A
supplementary and reinforced insulation .............. :
29.1 Clearances not less than the values specified in table P
16, taking into account the rated impulse voltage for
the overvoltage categories of table 15, unless
for basic insulation and functional insulation they N/A
comply with the impulse voltage test of clause 14
However, if the construction is affected by wear, P
distortion, movement of the parts or during assembly,
the clearances for rated impulse voltages of 1500V
and above are increased by 0,5 mm and the impulse
voltage test is not applicable
Impulse voltage test not applicable: -
- when the microenvironment is pollution degree 3 N/A
- for basic insulation of class 0 and class 01 N/A
appliances
Appliances are in overvoltage category II P
A force of 2 N is applied to bare conductors, other N/A
than heating elements
A force of 30 N is applied to accessible surfaces N/A
29.1.1 Clearances of basic insulation withstand the P
overvoltages, taking into account the rated impulse
voltage
Clearance at the terminals of tubular sheathed N/A
heating elements may be reduced to 1mm if the
microenvironment is pollution degree 1
Lacquered conductors of windings considered to be P
bare conductors
29.1.2 Clearances of supplementary insulation not less than N/A
those specified for basic insulation in table 16

TRF No. IEC60335_2_6J


Page 60 of 118 Report No:247713

IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict

29.1.3 Clearances of reinforced insulation not less than P


those specified for basic insulation in table 16, but
using the next higher step for rated impulse voltage
For double insulation, with no intermediate N/A
conductive part between basic and supplementary
insulation, clearances are measured between live
parts and the accessible surface, and the insulation
system is treated as reinforced insulation
29.1.4 Clearances for functional insulation are the largest values determined from: -
- table 16 based on the rated impulse voltage ...... : (see appended table) P
- table F.7a in IEC 60664-1, frequency not N/A
exceeding 30 kHz
- clause 4 of IEC 60664-4, frequency exceeding 30 N/A
kHz
If values of table 16 are largest, the impulse voltage N/A
test of clause 14 may be applied instead, unless
the microenvironment is pollution degree 3, or N/A
the distances can be affected by wear, distortion, N/A
movement of the parts or during assembly
However, clearances are not specified if the N/A
appliance complies with clause 19 with the
functional insulation short-circuited
Lacquered conductors of windings considered to be P
bare conductors
However, clearances at crossover points are not P
measured
Clearance between surfaces of PTC heating N/A
elements may be reduced to 1mm
29.1.5 Appliances having higher working voltages than rated voltage, clearances for basic -
insulation are the largest values determined from:
- table 16 based on the rated impulse voltage ...... : N/A
- table F.7a in IEC 60664-1, frequency not N/A
exceeding 30 kHz
- clause 4 of IEC 60664-4, frequency exceeding 30 N/A
kHz
If clearances for basic insulation are selected from N/A
Table F.7a of IEC 60664-1 or Clause 4 of IEC
60664-4, the clearances of supplementary insulation
are not less than those specified for basic insulation
If clearances for basic insulation are selected from N/A
Table F.7a of IEC 60664-1, the clearances of
reinforced insulation dimensioned as specified in
Table F.7a are to withstand 160% of the withstand
voltage required for basic insulation

TRF No. IEC60335_2_6J


Page 61 of 118 Report No:247713

IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict

If clearances for basic insulation are selected from N/A


Clause 4 of IEC 60664-4, the clearances of
reinforced insulation are twice the value required for
basic insulation
If the secondary winding of a step-down transformer N/A
is earthed, or if there is an earthed screen between
the primary and secondary windings, clearances of
basic insulation on the secondary side not less than
those specified in table 16, but using the next lower
step for rated impulse voltage
Circuits supplied with a voltage lower than rated N/A
voltage, clearances of functional insulation are
based on the working voltage used as the rated
voltage in table 15
29.2 Creepage distances not less than those appropriate
for the working voltage, taking into account the
material group and the pollution degree
Pollution degree 2 applies, unless P
precautions taken to protect the insulation; pollution N/A
degree 1
insulation subjected to conductive pollution; pollution N/A
degree 3
A force of 2 N is applied to bare conductors, other N/A
than heating elements
A force of 30 N is applied to accessible surfaces N/A
In a double insulation system, the working voltage P
for both the basic and supplementary insulation is
taken as the working voltage across the complete
double insulation system
The microenvironment is pollution degree 3 unless N/A
the insulation is enclosed or located so that it is
unlikely to be exposed to pollution during normal
use of the appliance
(IEC 60335-2-6:2002) (IEC 60335-2-13:2002)
29.2.1 Creepage distances of basic insulation not less than P
specified in table 17
However, if the working voltage is periodic and has N/A
a frequency exceeding 30 kHz, the creepage
distances are also determined from table 2 of IEC
60664-4, these values being used if exceeding the
values in table 17 .................................................. :
Except for pollution degree 1, corresponding N/A
creepage distance not less than the minimum
specified for the clearance in table 16, if the
clearance has been checked according to the test of
clause 14 ............................................................... :

TRF No. IEC60335_2_6J


Page 62 of 118 Report No:247713

IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict

29.2.2 Creepage distances of supplementary insulation at N/A


least as specified for basic insulation in table 17, or
Table 2 of IEC 60664-4, as applicable: N/A
29.2.3 Creepage distances of reinforced insulation at least P
double as specified for basic insulation in table 17, or
Table 2 of IEC 60664-4, as applicable: N/A
29.2.4 Creepage distances of functional insulation not less P
than specified in table 18
However, if the working voltage is periodic and has N/A
a frequency exceeding 30 kHz, the creepage
distances are also determined from table 2 of IEC
60664-4, these values being used if exceeding the
values in table 18:
Creepage distances may be reduced if the appliance N/A
complies with clause 19 with the functional insulation
short-circuited
29.3 Supplementary and reinforced insulation having P
adequate thickness, or a sufficient number of layers,
to withstand the electrical stresses
Compliance checked by: -
- measurement, in accordance with 29.3.1, or P
- an electric strength test in accordance with 29.3.2, N/A
or
- an assessment of the thermal quality of the material N/A
combined with an electric strength test, in accordance
with 29.3.3
for accessible parts of reinforced insulation N/A
consisting of a single layer, by measurement in
accordance with 29.3.4, or
- as specified in subclause 6.3 of IEC 60664-4 for N/A
insulation that is subjected to any periodic voltage
having a frequency exceeding 30 kHz
This requirement does not apply to the sheath of N/A
visibly glowing heating element inaccessible to test
probe 41 of IEC 61032 (IEC 60335-2-6:2002)
29.3.1 Supplementary insulation having a thickness of at N/A
least 1 mm
Reinforced insulation having a thickness of at least 2 P
mm
29.3.2 Each layer of material withstand the electric strength N/A
test of 16.3 for supplementary insulation
Supplementary insulation consisting of at least 2 N/A
layers

TRF No. IEC60335_2_6J


Page 63 of 118 Report No:247713

IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict

Reinforced insulation consisting of at least 3 layers N/A


29.3.3 The insulation is subjected to the dry heat test Bb of N/A
IEC 60068-2-2, followed by
the electric strength test of 16.3 N/A
If the temperature rise during the tests of Clause 19 N/A
does not exceed the value specified in Table 3, the
test of IEC 60068-2-2 is not carried out
29.3.4 Thickness of accessible parts of reinforced N/A
insulation consisting of a single layer not less than
specified in table 19 .............................................. :

30 RESISTANCE TO HEAT AND FIRE


30.1 External parts of non-metallic material, P
parts supporting live parts, and P
thermoplastic material providing supplementary or N/A
reinforced insulation,
sufficiently resistant to heat P
Ball-pressure test according to IEC 60695-10-2 P
External parts: at 40 C plus the maximum (see appended table) P
temperature rise determined during the test of clause
11, or at 75 C, whichever is the higher; temperature
(C) ........................................................................... :
Parts supporting live parts: at 40C plus the (see appended table) P
maximum temperature rise determined during the
test of clause 11, or at 125C, whichever is the
higher; temperature (C) .......................................... :
Parts of thermoplastic material providing N/A
supplementary or reinforced insulation, 25C plus the
maximum temperature rise determined during clause
19, if higher; temperature (C) ................................. :
30.2 Parts of non-metallic material adequately resistant to P
ignition and spread of fire
This requirement does not apply to: -
parts having a mass not exceeding 0,5 g, provided N/A
the cumulative effect is unlikely to propagate flames
that originate inside the appliance by propagating
flames from one part to another, or
decorative trims, knobs and other parts unlikely to be N/A
ignited or to propagate flames that originate inside
the appliance
Compliance checked by the test of 30.2.1. P
In addition:

TRF No. IEC60335_2_6J


Page 64 of 118 Report No:247713

IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict

- attended appliances, 30.2.2 applies N/A


- unattended appliances, 30.2.3 applies P
Appliances for remote operation, 30.2.3 applies N/A
Base material of printed circuit board, 30.2.4 applies P
For induction wok elements, grills and griddles that N/A
do not incorporate a timer , 30.2.2 is applicable (IEC
60335-2-6:2002)
For other appliances, 30.2.3 is applicable (IEC P
60335-2-6:2002)
30.2.1 Parts of non-metallic material subjected to the glow- P
wire test of IEC 60695-2-11 at 550 C
However, test not carried out if the material is N/A
classified as having a glow-wire flammability index
according to IEC 60695-2-12 of at least 550 C, or
the material is classified at least HB40 according to N/A
IEC 60695-11-10
Parts for which the glow-wire test cannot be carried N/A
out need to meet the requirements in ISO 9772 for
material classified HBF
30.2.2 Appliances operated while attended, parts of non- N/A
metallic material supporting current-carrying
connections, and parts of non-metallic material within
a distance of 3mm of such connections, are
subjected to the glow-wire test of IEC 60695-2-11.
The test severity is: -
- 750 C, for connections carrying a current N/A
exceeding 0,5 A during normal operation
- 650 C, for other connections N/A
Glow-wire applied to an interposed shielding N/A
material, if relevant
The glow-wire test is not carried out on parts of material classified as having a glow- N/A
wire flammability index according to IEC 60695-2-12 of at least:
- 750 C, for connections carrying a current N/A
exceeding 0,5 A during normal operation
- 650 C, for other connections N/A
The glow-wire test is also not carried out on small N/A
parts. These parts are to:
- comprise material having a glow-wire flammability N/A
index of at least 750 C, or 650 C as appropriate,
or
- comply with the needle-flame test of Annex E, or N/A

TRF No. IEC60335_2_6J


Page 65 of 118 Report No:247713

IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict

- comprise material classified as V-0 or V-1 N/A


according to IEC 60695-11-10 .............................. :
Glow-wire test not applicable to conditions as N/A
specified ...............................................................
30.2.3 Appliances operated while unattended, tested as P
specified in 30.2.3.1 and 30.2.3.2
Tests not applicable to conditions as specified N/A
30.2.3.1 Parts of insulating material supporting connections P
carrying a current exceeding 0.2A during normal
operation, and
parts of non-metallic material within a distance of N/A
3mm,
subjected to the glow-wire test of IEC 60695-2-11 P
with a test severity of 850°C
Glow-wire applied to an interposed shielding N/A
material, if relevant
The glow-wire test is not carried out on parts of N/A
material classified as having a glow-wire
flammability index according to IEC 60695-2-12 of
at least 850 °C
30.2.3.2 Parts of non-metallic material supporting current- P
carrying connections, and
parts of non-metallic material within a distance of N/A
3mm,
subjected to glow-wire test of IEC 60695-2-11 P
The test severity is: N/A
- 750 C, for connections carrying a current P
exceeding 0,2 A during normal operation
- 650 C, for other connections N/A
Glow-wire applied to an interposed shielding N/A
material, if relevant
However, the glow-wire test of 750 C or 650 C as appropriate, is not carried out on N/A
parts of material fulfilling both or either of the following classifications:
- a glow-wire ignition temperature according to IEC N/A
60695-2-13 of at least:
 775 C, for connections carrying a current N/A
exceeding 0,2 A during normal operation
 675 C, for other connections N/A
- a glow-wire flammability index according to IEC N/A
60695-2-12 of at least:
- 750 C, for connections carrying a current N/A
exceeding 0,2 A during normal operation

TRF No. IEC60335_2_6J


Page 66 of 118 Report No:247713

IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict

- 650 C, for other connections N/A


The glow-wire test is also not carried out on small parts. These parts are to: N/A
- comprise material having a glow-wire ignition N/A
temperature of at least 775 C or 675 C as
appropriate, or
- comprise material having a glow-wire flammability N/A
index of at least 750 C or 650 C as appropriate, or
- comply with the needle-flame test of Annex E, or N/A
- comprise material classified as V-0 or V-1 N/A
according to IEC 60695-11-10
The consequential needle-flame test of Annex E applied to non-metallic parts that N/A
encroach within the vertical cylinder placed above the centre of the connection zone
and on top of the non-metallic parts supporting current-carrying connections, and
parts of non-metallic material within a distance of 3 mm of such connections if these
parts are those:
- parts that withstood the glow-wire test of IEC N/A
60695-2-11 of 750 C or 650 C as appropriate, but
produce a flame that persist longer than 2 s, or
- parts that comprised material having a glow-wire N/A
flammability index of at least 750 C or 650 C as
appropriate, or
- small parts, that comprised material having a N/A
glow-wire flammability index of at least 750 C or
650 C as appropriate, or
- small parts for which the needle-flame test of N/A
Annex E was applied, or
- small parts for which a material classification of V- N/A
0 or V-1 was applied
However, the consequential needle-flame test is not carried out on non-metallic -
parts, including small parts, within the cylinder that are:
- parts having a glow-wire ignition temperature of at N/A
least 775 C or 675 C as appropriate, or
- parts comprising material classified as V-0 or V-1 N/A
according to IEC 60695-11-10, or
- parts shielded by a flame barrier that meets the N/A
needle-flame test of Annex E or that comprises
material classified as V-0 or V-1 according to IEC
60695-11-10
30.2.4 Base material of printed circuit boards subjected to N/A
needle-flame test of annex E
Test not applicable to conditions as specified V-0 P

31 RESISTANCE TO RUSTING

TRF No. IEC60335_2_6J


Page 67 of 118 Report No:247713

IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict

Relevant ferrous parts adequately protected against P


rusting

32 RADIATION, TOXICITY AND SIMILAR HAZARDS


Appliance shall not emit harmful radiation, present a P
toxic or similar hazard due to their operation in
normal use
Relevant tests specified in part 2, if necessary N/A
32.101 Pyrolytic self-cleaning ovens shall be constructed N/A
so that the carbon monoxide is not discharged in
hazardous quantities during cleaning
(IEC 60335-2-6:2002)

A ANNEX A (INFORMATIVE)
ROUTINE TESTS
Description of routine tests to be carried out by the See CIG023 report P
manufacturer

B ANNEX B (NORMATIVE)
APPLIANCES POWERED BY RECHARGEABLE BATTERIES
The following modifications to this standard are N/A
applicable for appliances powered by batteries that
are recharged in the appliance
This annex does not apply to battery chargers N/A
3.1.9 Appliance operated under the following conditions: N/A
-the appliance, supplied by its fully charged battery, N/A
operated as specified in relevant part 2
-the battery is charged, the battery being initially N/A
discharged to such an extent that the appliance
cannot operate
-if possible, the appliance is supplied from the supply N/A
mains through its battery charger, the battery being
initially discharged to such an extent that the
appliance cannot operate. The appliance is operated
as specified in relevant part 2
If the appliance incorporates inductive coupling N/A
between two parts that are detachable from each
other, the appliance is supplied from the supply
mains with the detachable part removed
3.6.2 Part to be removed in order to discard the battery is N/A
not considered to be detachable

TRF No. IEC60335_2_6J


Page 68 of 118 Report No:247713

IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict

5.101 Appliances supplied from the supply mains tested as N/A


specified for motor-operated appliances
7.1 Battery compartment for batteries intended to be N/A
replaced by the user, marked with battery voltage
and polarity of the terminals
7.12 The instructions for appliances incorporating N/A
batteries intended to be replaced by the user includes
required information
Details about how to remove batteries containing N/A
materials hazardous to the environment given
7.15 Markings placed on the part of the appliance N/A
connected to the supply mains
8.2 Appliances having batteries that according to the N/A
instruction may be replaced by the user need only
have basic insulation between live parts and the inner
surface of the battery compartment
If the appliance can be operated without batteries, N/A
double or reinforced insulation required
11.7 The battery is charged for the period described N/A
19.1 Appliances subjected to tests of 19.101, 19.102 and N/A
19.103
19.101 Appliances supplied at rated voltage for 168 h, the N/A
battery being continually charged
19.102 Short-circuiting of the terminals of the battery, being N/A
fully charged, for appliances having batteries that can
be removed without the aid of a tool
19.103 Appliances having batteries replaceable by the user N/A
supplied at rated voltage under normal operation with
the battery removed or in any position allowed by the
construction
21.101 Appliances having pins for insertion into socket- N/A
outlets have adequate mechanical strength, checked
according to procedure 2 of IEC 68-2-32
Part of the appliance incorporating the pins subjected to the free fall test, procedure 2, -
of IEC 60068-2-32, the number of falls being:
- 100, the mass of part does not exceed 250 g N/A
- 50, the mass of part exceeds 250 g N/A
After the test, the requirements of 8.1, 15.1.1, 16.3 N/A
and clause 29 are met
22.3 Appliances having pins for insertion into socket- N/A
outlets tested as fully assembled as possible

TRF No. IEC60335_2_6J


Page 69 of 118 Report No:247713

IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict

25.13 An additional lining or bushing not required for N/A


interconnection cords operating at safety extra-low
voltage
30.2 For parts of the appliance connected to the supply N/A
mains during the charging period, 30.2.3 applies
For other parts, 30.2.2 applies N/A

C ANNEX C (NORMATIVE)
AGEING TEST ON MOTORS
Tests, as described, carried out when doubt with N/A
regard to the temperature classification of the
insulation of a motor winding

D ANNEX D (NORMATIVE)
THERMAL MOTOR PROTECTORS
Applicable to appliances having motors that N/A
incorporate thermal motor protectors

E ANNEX E (NORMATIVE)
NEEDLE-FLAME TEST
Needle-flame test carried out in accordance with N/A
IEC 60695-11-5, with the following modifications:
7 Severities -
The duration of application of the test flame is N/A
30 s ± 1 s
9 Test procedure -
9.1 The specimen so arranged that the flame can be N/A
applied to a vertical or horizontal edge as shown in
the examples of figure 1
9.2 The first paragraph does not apply N/A
If possible, the flame is applied at least 10 mm from a N/A
corner
9.3 The test is carried out on one specimen N/A
If the specimen does not withstand the test, the test N/A
may be repeated on two additional specimens, both
withstanding the test
10 Evaluation of test results -
The duration of burning not exceeding 30 s N/A
However, for printed circuit boards, the duration of N/A
burning not exceeding 15 s

TRF No. IEC60335_2_6J


Page 70 of 118 Report No:247713

IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict

F ANNEX F (NORMATIVE)
CAPACITORS
Capacitors likely to be permanently subjected to the N/A
supply voltage, and used for radio interference
suppression or voltage dividing, comply with the
following clauses of IEC 60384-14, with the following
modifications:
1.5 Terminology -
1.5.3 Class X capacitors tested according to subclass X2 N/A
1.5.4 This subclause is applicable N/A
1.6 Marking -
Items a) and b) are applicable N/A
3.4 Approval testing -
3.4.3.2 Table II is applicable as described N/A
4.1 Visual examination and check of dimensions -
This subclause is applicable N/A
4.2 Electrical tests -
4.2.1 This subclause is applicable N/A
4.2.5 This subclause is applicable N/A
4.2.5.2 Only table IX is applicable N/A
Values for test A apply N/A
However, for capacitors in heating appliances the N/A
values for test B or C apply
4.12 Damp heat, steady state -
This subclause is applicable N/A
Only insulation resistance and voltage proof are N/A
checked
4.13 Impulse voltage -
This subclause is applicable N/A
4.14 Endurance -
Subclauses 4.14.1, 4.14.3, 4.14.4 and 4.14.7 N/A
applicable
4.14.7 Only insulation resistance and voltage proof are N/A
checked
Visual examination, no visible damage N/A
4.17 Passive flammability test -

TRF No. IEC60335_2_6J


Page 71 of 118 Report No:247713

IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict

This subclause is applicable N/A


4.18 Active flammability test -
This subclause is applicable N/A

G ANNEX G (NORMATIVE)
SAFETY ISOLATING TRANSFORMERS
The following modifications to this standard are N/A
applicable for safety isolating transformers:
7 Marking and instructions -
7.1 Transformers for specific use marked with: -
-name, trademark or identification mark of the N/A
manufacturer or responsible vendor
-model or type reference N/A
17 Overload protection of transformers and associated circuits -
Fail-safe transformers comply with subclause 15.5 of N/A
IEC 61558-1
22 Construction -
Subclauses 19.1 and 19.1.2 of IEC 61558-2-6 are N/A
applicable
29 Clearances, creepage distances and solid insulation -
29.1, 29.2 The distances specified in items 2a, 2c and 3 in table N/A
and 29.3 13 of IEC 61558-1 apply

H ANNEX H (NORMATIVE)
SWITCHES
Switches comply with the following clauses of IEC 61058-1, as modified: -
-The tests of IEC 61058-1 carried out under the N/A
conditions occurring in the appliance
-Before being tested, switches are operated 20 times N/A
without load
8 Marking and documentation -
Switches are not required to be marked N/A
However, switches that can be tested separately N/A
from the appliance marked with the manufacturer’s
name or trade mark and the type reference
13 Mechanism -
The tests may be carried out on a separate sample N/A
15 Insulation resistance and dielectric strength -

TRF No. IEC60335_2_6J


Page 72 of 118 Report No:247713

IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict

15.1 Not applicable N/A


15.2 Not applicable N/A
15.3 Applicable for full disconnection and micro- N/A
disconnection
17 Endurance -
Compliance is checked on three separate appliances N/A
or switches
For 17.2.4.4, the number of cycles is 10 000, unless N/A
otherwise specified in 24.1.3 of the relevant part 2 of
IEC 60335
Switches for operation under no load and which can N/A
be operated only by a tool and switches operated by
hand that are interlocked so that they cannot be
operated under load, are not subjected to the tests
Subclauses 17.2.2 and 17.2.5.2 not applicable N/A
The ambient temperature during the test is that N/A
occurring in the appliance during the test of Clause
11 in IEC 60335-1
Temperature rise of the terminals not more than 30 K N/A
above the temperature rise measured in clause 11 of
IEC 60335-1
20 Clearances, creepage distances, solid insulation and coatings of rigid printed board -
assemblies
This clause is applicable to clearances and creepage N/A
distances for functional insulation, across full
disconnection and micro-disconnection, as stated in
table 24

I ANNEX I (NORMATIVE)
MOTORS HAVING BASIC INSULATION THAT IS INADEQUATE FOR THE RATED
VOLTAGE OF THE APPLIANCE
The following modifications to this standard are N/A
applicable for motors having basic insulation that is
inadequate for the rated voltage of the appliance:
8 Protection against access to live parts -
8.1 Metal parts of the motor are considered to be bare N/A
live parts
11 Heating -
11.3 Temperature rise of the body of the motor is N/A
determined instead of the temperature rise of the
windings

TRF No. IEC60335_2_6J


Page 73 of 118 Report No:247713

IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict

11.8 Temperature rise of the body of the motor, where in N/A


contact with insulating material, not exceeding values
in table 3 for the relevant insulating material
16 Leakage current and electric strength -
16.3 Insulation between live parts of the motor and its N/A
other metal parts not subjected to the test
19 Abnormal operation
19.1 The tests of 19.7 to 19.9 not carried out N/A
19.101 Appliance operated at rated voltage with each of the following fault conditions: -
- short circuit of the terminals of the motor, including N/A
any capacitor incorporated in the motor circuit
- short circuit of each diode of the rectifier N/A
- open circuit of the supply to the motor N/A
- open circuit of any parallel resistor, the motor being N/A
in operation
Only one fault simulated at a time, the tests carried N/A
out consecutively
22 Construction -
22.101 For class I appliances incorporating a motor supplied N/A
by a rectifier circuit, the d.c. circuit being insulated
from accessible parts of the appliance by double or
reinforced insulation
Compliance checked by the tests specified for double N/A
and reinforced insulation

J ANNEX J (NORMATIVE)
COATED PRINTED CIRCUIT BOARDS
Testing of protective coatings of printed circuit boards N/A
carried out in accordance with IEC 60664-3 with the
following modifications:
5.7 Conditioning of the test specimens -
When production samples are used, three samples N/A
of the printed circuit board are tested
5.7.1 Cold -
The test is carried out at -25C N/A
5.7.3 Rapid change of temperature -
Severity 1 is specified N/A
5.9 Additional tests -
This subclause is not applicable N/A

TRF No. IEC60335_2_6J


Page 74 of 118 Report No:247713

IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict

K ANNEX K (NORMATIVE)
OVERVOLTAGE CATEGORIES
The information on overvoltage categories is P
extracted from IEC 60664-1
Overvoltage category is a numeral defining a P
transient overvoltage condition
Equipment of overvoltage category IV is for use at N/A
the origin of the installation
Equipment of overvoltage category III is equipment in N/A
fixed installations and for cases where the reliability
and the availability of the equipment is subject to
special requirements
Equipment of overvoltage category II is energy P
consuming equipment to be supplied from the fixed
installation
If such equipment is subjected to special N/A
requirements with regard to reliability and availability,
overvoltage category III applies
Equipment of overvoltage category I is equipment for N/A
connection to circuits in which measures are taken to
limit transient overvoltages to an appropriate low level

L ANNEX L (INFORMATIVE)
GUIDANCE FOR THE MEASUREMENT OF CLEARANCES AND CREEPAGE
DISTANCES
Sequences for the determination of clearances and P
creepage distances

M ANNEX M (NORMATIVE)
POLLUTION DEGREE
The information on pollution degrees is extracted P
from IEC 60664-1
Pollution -
The microenvironment determines the effect of P
pollution on the insulation, taking into account the
macroenvironment
Means may be provided to reduce pollution at the P
insulation by effective enclosures or similar
Minimum clearances specified where pollution may P
be present in the microenvironment
Degrees of pollution in the microenvironment -

TRF No. IEC60335_2_6J


Page 75 of 118 Report No:247713

IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict

For evaluating creepage distances, the following degrees of pollution in the -


microenvironment are established:
- pollution degree 1: no pollution or only dry, non- N/A
conductive pollution occurs. The pollution has no
influence
- pollution degree 2: only non-conductive pollution P
occurs, except that occasionally a temporary
conductivity caused by condensation is to be
expected
- pollution degree 3: conductive pollution occurs or N/A
dry non-conductive pollution occurs that becomes
conductive due to condensation that is to be
expected
- pollution degree 4: the pollution generates N/A
persistent conductivity caused by conductive dust or
by rain or snow

N ANNEX N (NORMATIVE)
PROOF TRACKING TEST
The proof tracking test is carried out in accordance N/A
with IEC 60112 with the following modifications:
7 Test apparatus -
7.3 Test solutions -
Test solution A is used N/A
10 Determination of proof tracking index (PTI) -
10.1 Procedure -
The proof voltage is 100V, 250V, 175V, 400V or N/A
600V ......................................................................... :
The last paragraph of Clause 3 applies N/A
The test is carried out on five specimens N/A
In case of doubt, additional test with proof voltage N/A
reduced by 25V, the number of drops increased to
100
10.2 Report -
The report stating if the PTI value was based on a N/A
test using 100 drops with a test voltage of (PTI-25) V

O ANNEX O (INFORMATIVE)
SELECTION AND SEQUENCE OF THE TESTS OF CLAUSE 30
Description of tests for determination of resistance to N/A
heat and fire

TRF No. IEC60335_2_6J


Page 76 of 118 Report No:247713

IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict

P ANNEX P (INFORMATIVE)
GUIDANCE FOR THE APPLICATION OF THIS STANDARD TO APPLIANCES
USED IN WARM DAMP EQUABLE CLIMATES
Modifications applicable for class 0 and 01 appliances having a rated voltage -
exceeding 150V, intended to be used in countries having a warm damp equable
climate and that are marked WDaE
Modifications may also be applied to class 1 appliances having a rated voltage -
exceeding 150V, intended to be used in countries having a warm damp equable
climate and that are marked WdaE, if liable to be connected to a supply mains that
excludes the protective earthing conductor
5 General conditions for the tests -
5.7 The ambient temperature for the tests of Clauses 11 N/A
+3
and 13 is 40 /0
7 Marking and instructions -
7.1 The appliance marked with the letters WDaE N/A
7.12 The instructions state that the appliance is to be N/A
supplied through a RCD having a rated residual
operating current not exceeding 30 mA
The instructions state that the appliance is N/A
considered to be suitable for use in countries having
a warm damp equable climate, but may also be used
in other countries
11 Heating -
11.8 The values of Table 3 are reduced by 15 K N/A
13 Leakage current and electric strength at operating temperature -
13.2 The leakage current for class I appliances not N/A
exceeding 0,5 mA
15 Moisture resistance -
15.3 The value of t is 37 C N/A
16 Leakage current and electric strength -
16.2 The leakage current for class I appliances not N/A
exceeding 0,5 mA
19 Abnormal operation -
19.13 The leakage current test of 16.2 is applied in addition N/A
to the electric strength test of 16.3

Q ANNEX Q (INFORMATIVE)
SEQUENCE OF TESTS FOR THE EVALUATION OF ELECTRONIC CIRCUITS
Description of tests for appliances incorporating electronic circuits -

TRF No. IEC60335_2_6J


Page 77 of 118 Report No:247713

IEC 60335-2-6
Clause Requirement + Test Result - Remark Verdict

R ANNEX R (NORMATIVE)
SOFTWARE EVALUATION
Software evaluated in accordance with the following clauses of Annex H of IEC 60730- -
1, as modified

H.2 Definitions -
Only definitions H.2.16 to H.2.20 applicable N/A
H.7 Information -
Only footnotes 12) to 18) of Table 7.2, as modified, N/A
applicable
H.11.12 Controls using software -
All the subclauses of H.11.12, as modified, except N/A
H.11.12.6 and H.11.12.6.1, applicable
H.11.12.7 Delete text N/A
H.11.12.7.1 For appliances using software class C having a N/A
single channel with self-test and monitoring structure,
the manufacturer provides the measures necessary
to address the fault/errors in safety related segments
and data
H.11.12.8 Software fault/error detection occurs before N/A
compliance with 19.13 of IEC 60335-1 is impaired
H.11.12.8.1 Replace text N/A
H.11.12.13 Software and safety related hardware under its N/A
control initializes and terminates before compliance
with 19.13 of IEC 60335-1 is impaired

TRF No. IEC60335_2_6J


Page 78 of 118 Report No:247713

IEC 60335-2-6

10.1 TABLE: Power input deviation P


Input deviation of/at: P rated (W) P measured dP Required dP Remark
(W)
230V
Hob elements of 1000W 1000 1000 0% +5%/-10% P
Hob elements of 1200W 1200 1175-1238 -2,1%/+3,2% +5%/-10% P
Hob elements of 1700W 1700 1695-1755 -0,3%/ +5%/-10% P
+3,24%
Hob elements of 1800W 1800 1800-1858 0%/+3,22% +5%/-10% P
Hob elements of 2000W 2000 2000 0% +5%/-10% P
Hob elements of 2100W 2100 2060-2133 -1,9%/ +5%/-10% P
+1,57%
Hob elements of 2200W 2200 2205-2220 +0,2%/+0,9 +5%/-10% P
%
Hob elements of 2400W 2400 2385 -0,6% +5%/-10% P
Hob element 700/2000W 700/2000 700/2040 0%/+2% +5%/-10% P
Hob element 1400/2200W 1400/2200 1410/2190 0.7%/-0.45% +5%/-10% P
Hob element 600W 600 600 0% +5%/-10% P
Total Various Various (*) +5%/-10% P

P58 EO6200 (230V) 6200 6100 -1,6% +5% / -10% P


230V (EC6700) 6700 6600 -1,5% +5%/-10% P
230V (EC5500) 5500 5580 +1,5% +5%/-10% P

P58 EO6900 (230V) 6900 6780 -1,74% +5% / -10% P


Hob element EIKA res. 2300 2280 -0,9% +5%/-10% P
Hob element EGO res. 2300 2280 -0,9% +5%/-10% P

Hob element, 1700/700W 1700/700 1670/684 -1,8%/-2,3% +5%/-10% Double Zone


E.G.O
10.58213.004
)
* : As long as each of the hob elements separately are within the limits of +5%/-10%, then the various
combinations of hob elements being used for the different types will also be within the limit.

10.2 TABLE: Current deviation N/A


Current deviation of/at: I rated (A) I measured (A) dI Required dI Remark

TRF No. IEC60335_2_6J


Page 79 of 118 Report No:247713

IEC 60335-2-6

11.7 TABLE: heating temperature specifications P


test step n°/ function temperature duration Model
1. Hob - 60 min EO6800 w. eika
2.Hob - 60 min EO6800 w. DIEHL
3. Hob - 60 min RV6300
4. Hob - 60 min EV6200
5. Hob - 60 min EO6200
6.Hob - 60 min EO6400
7.Hob - 60 min MV5900
8.Hob - 60 min EO6800 w. EGO
9.Hob - 60 min EO5400 w. DIEHL
10.Hob - 60 min EO6700 w. DIEHL
11.Hob - 60 min EO6200 w. eika
12.Hob - 60 min EC6700 w. eika
13.Hob - 60 min EC5500 w. eika
14.Hob - 60 min EO6900 w. eika
15.Hob - 60 min EC6700 w. eika
16.Hob - 60 min EC5400 w. eika
17.Hob - 60 min EO6400 w. eika

TRF No. IEC60335_2_6J


Page 80 of 118 Report No:247713

IEC 60335-2-6

11.8 (1.) TABLE: Heating test, thermocouples P

TYPE P58…… MODEL EO6800 with EIKA electronic board


8A 1..0 360….. or 8B.1..0 360…..
Test voltage (V) .................................................... : 258V (8515W) 
Ambient (C) ......................................................... : 23.5 
Thermocouple locations dT (K) Max. dT (K)
Supply cord 18 50
Terminal block 30 60
Internal wires (glass fibre) near 2200W 94 155
element (T180)
Thermostat body (T250) 107 225
Printed circuit board 43 Cfr.cl.30
Bottom plate of the appliance, against the 70 -
floor of the test corner
Test corner floor, 25mm blow bottom 25 70
plate of the appliance
Built-in frame 61 70
Test corner walls 19 70
Transformer cover 60 Cfr.cl.30
Touch control 22 45
(Touched only for short period during
normal use)
Relay cover 56 Cfr.cl.30

TRF No. IEC60335_2_6J


Page 81 of 118 Report No:247713

IEC 60335-2-6

(2.) TYPE P58…… MODEL EO6800 with DIEHL electronic board


TC-4SE-Z-XX-YY-105-U230
Test voltage (V) .................................................... : 258V (8515W) 
Ambient (C) ......................................................... : 23.7 
Thermocouple locations dT (K) Max. dT (K)
Supply cord 19 50
Terminal block 33 60
Internal wires (glass fibre) near 2200W 98 155
element (T180)
Thermostat body (T250) 112 225
Printed circuit board 59 Cfr.cl.30
Bottom plate of the appliance, against the 73 -
floor of the test corner
Test corner floor, 25mm blow bottom 29 70
plate of the appliance
Built-in frame 63 70
Test corner walls 23 70
Plastic parts of transformer 50 Cfr.cl.30
Touch control 38 45
(Touched only for short period during
normal use)
Relay cover 56 Cfr.cl.30
03100 Coil winding (Class E) 57 80
X2 0.1μF capacitor T110 56 85

TRF No. IEC60335_2_6J


Page 82 of 118 Report No:247713

IEC 60335-2-6

(3.) TYPE P58…… MODEL RV6300


Test voltage (V) .................................................... : 256.7V (7889W) 
Ambient (C) ......................................................... : 23.5 
Thermocouple locations dT (K) Max. dT (K)
Supply cord 40 50
Terminal block 59 60/85/115
Internal wires (glass fibre) near 1800W 90 155
element (T180)
Internal wires (glass fibre) PCB (T180) 80 155
Internal wires (glass fibre) near 2100W 110 155
element (T180)
Thermostat body (T250) 202 225
Energy regulator, MSA-V01, T125 118 Cfr. cl. 30**
Energy regulator, MSA-V03, T125 115 Cfr. cl. 30**
Energy regulator, MSA 369-TW, T125 123 Cfr. cl. 30**
Printed circuit board, T105 72 80
Lamps on PCB 63 Cfr.cl.30
Knob 25 45
Bottom plate of the appliance, against the 70 -
floor of the test corner
Test corner floor, 25mm blow bottom 25 70
plate of the appliance
Built-in frame LF 70 70
Built-in frame RF 70 70
Built-in frame RB 65 70
Test corner walls 24 70
**) the component exceeds the T-marking. It was tested for cl.30 for the conditions occurring in the
appliance.

TRF No. IEC60335_2_6J


Page 83 of 118 Report No:247713

IEC 60335-2-6

(4.) TYPE P58…… MODEL EV6200


Test voltage (V) .................................................... : 255.8V (7763W) 
Ambient (C) ......................................................... : 23.5 
Thermocouple locations dT (K) Max. dT (K)
Supply cord 31 50
Terminal block 40 60/85/115
Internal wires (glass fibre) near 1700W 90 155
element (T180)
Internal wires PCB 90°C 58 65
Internal wires (glass fibre) near 2100W 110 155
element (T180)
Thermostat body T250°C 202 225
Transformer Enclosure 78 Cfr. cl. 30
Relay cover 58 Cfr. cl. 30
Printed circuit board, T130 67 105
Surface of touch control area 25 45
Bottom plate of the appliance, against the 94
floor of the test corner
Test corner floor 25 70
Built-in frame LF 70 70
Built-in frame LB 65 70
Test corner walls 24 70

TRF No. IEC60335_2_6J


Page 84 of 118 Report No:247713

IEC 60335-2-6

(5.) TYPE P58…… MODEL EO6200


Test voltage (V) .................................................... : 255.8V (7763W) 
Ambient (C) ......................................................... : 22.5 
Thermocouple locations dT (K) Max. dT (K)
Supply cord 40 50
Terminal block, KADO 2/5 72 Cfr. cl. 30
Internal wires (glass fibre) near 1700W 79 155
element (T180)
Internal wires (glass fibre) near 2100W 140 155
element (T180)
Thermostat body T250°C 202 225
Transformer, STEGER Enclosure 63 Cfr. cl. 30
Transformer, BOBINADOS ta105 60 80
Relay NAIS cover 57 Cfr. cl. 30
Relay Schrack cover 48 Cfr. cl. 30
Printed circuit board, 44 Cfr. cl. 30
Surface of touch control area 25 45
Bottom plate of the appliance, against the 84 -
floor of the test corner
Test corner floor 25 70
Built-in frame LB 60 70
Built-in frame RB 58 70
Test corner walls 24 70

TRF No. IEC60335_2_6J


Page 85 of 118 Report No:247713

IEC 60335-2-6

(6.) TYPE P58…… MODEL EO6400


Test voltage (V) .................................................... : 259V (7950W) 
Ambient (C) ......................................................... : 25.0 
Thermocouple locations dT (K) Max. dT (K)
Wood frame Right – rear element 23 70
Wood frame Right – front element 11 70
Wood frame Left – rear element 23 70
Wood frame Left – front element 30 70
Wood frame Front – right element 17 70
Wood frame Front – left element 35 70
Wood frame Rear – right element 39 70
Wood frame Rear – left element 41 70
Trafo Surface ta70 43 45
Test corner walls 17 70

TRF No. IEC60335_2_6J


Page 86 of 118 Report No:247713

IEC 60335-2-6

(7.) TYPE P58…… MODEL MV5900


Test voltage (V) .................................................... : 255.7V (7388W) 
Ambient (C) ......................................................... : 24.0 
Thermocouple locations dT (K) Max. dT (K)
Supply cord 40 50
Terminal block 59 60/85/115
Internal wires (glass fibre) near 1800W 90 155
element (T180)
Internal wires (glass fibre) PCB (T180) 80 155
Thermostat body T250°C 202 225
Energy regulator, MSA-V01, T125 95 100
Energy regulator, MSA-312-TW, T125 116 Cfr. cl. 30**
Energy regulator, MSA-369-TW, T125 121 Cfr. cl. 30**
Energy regulator, MSA-V03, T125 95 100
Energy regulator, EGO, T125 84 100
Switches, EGO, 41.41723.005, T140 95 115
Printed circuit board, T105 72 80
Lamps on PCB 63 cfr. §30
Knob 25 45
Bottom plate of the appliance, against the 70 70
floor of the test corner
Test corner floor 34 70
Built-in frame LF 70 70
Built-in frame RB 61 70
Test corner walls 31 70
**) The component exceed the T-marking. It was tested for cl. 30 for the conditions occurring in the
appliance.

TRF No. IEC60335_2_6J


Page 87 of 118 Report No:247713

IEC 60335-2-6

(8.) TYPE P58…… MODEL EO6800 with EGO electronic board


75.13061.201 (4 relays) or 75.13061.202 (5 relays)
Test voltage (V) .................................................... : 258V (8515W) 
Ambient (C) ......................................................... : 22.0 
Thermocouple locations dT (K) Max. dT (K)
PCB 65 Cfr.cl.30
Relay Tyco Schrack LNA333012-01 59 Considered as class 105(A)
windings 65
Plastic parts of transformer ERA UI30/.. 69 Cfr.cl.30

(9.) TYPE P58…… MODEL EO5400 with DIEHL electronic board


TC3-Q-9T-4R-U230
Test voltage (V) .................................................... : 258V (8515W) 
Ambient (C) ......................................................... : 22.0 
Thermocouple locations dT (K) Max. dT (K)
Finder relay type 45.71.7.006.0310 55 Considered as class 105(A)
65
Relay NAIS JS1a-B-6V-F-H150 60 Considered as class 105(A)
65
PCB 57 Cfr.cl.30
Coil Tokin 03100 Class E 74 80
Plastic parts of transformer Kaschke 64 Cfr.cl.30
063.682
X2 BC capacitor T105 67 80

TRF No. IEC60335_2_6J


Page 88 of 118 Report No:247713

IEC 60335-2-6

(10.) TYPE P58…… MODEL EO6700 with DIEHL electronic board


TC4 Standard H
Test voltage (V) .................................................... : 261V (8390W) 
Ambient (C) ......................................................... : 20.0 
Thermocouple locations dT (K) Max. dT (K)
PCB 63 Cfr.cl.30
X2 Capacitor T110 47 85
Plastic part of trafo Kaschke 451 761 51 Cfr.cl.30
Coil 03100 Class E windings 69 95
Fast on cover 74 Cfr.cl.30
Relay Tyco Schrack LNH33006 enclosure 57 Cfr.cl.30
Relay Tyco Schrack RFH34006 enclosure 52 Cfr.cl.30
Glass ceramic of touch control 25 45

(11.) TYPE P58…… MODEL EO6200 with EIKA electronic board


BJ3xxA36211101
Test voltage (V) .................................................... : 261V (7,76kW) 
Ambient (C) ......................................................... : 22 
Thermocouple locations dT (K) Max. dT (K)
Supply cord (T90) 31 65
X2 capacitor (T110) 38 85
Transformer 36 65
Relay (LNH33012) #1 37 65
Relay (LNH33012) #2 39 65
PCB 38 120
Test enclosure 39 65

TRF No. IEC60335_2_6J


Page 89 of 118 Report No:247713

IEC 60335-2-6

11.8 (12.) TABLE: Heating test, thermocouples P


TYPE P58…… MODEL EC6700 with new PCB control unit
PCB control unit: EIKA _ BG361336011103
Test voltage (V) .................................................... : 260V (8,39kW) 
Ambient (C) ......................................................... : 22,5 
Thermocouple locations dT (K) Max. dT (K)
Supply cord (T90) 48 65
X2 capacitor (T110) 47 85
Transformer 50 65
Relay (LNH33012) 1 58 65
Relay (LNH33012) 2 59 65
PCB 59 120

(13.) TYPE P58…… MODEL EC5500 with new PCB control unit and new heating element
PCB control unit: EIKA _ BG341336011109
Heating element: EGO _ 10.53211.004 / EIKA _ 2502333912
Test voltage (V) .................................................... : 257V (6,89kW) 
Ambient (C) ......................................................... : 23,5 
Thermocouple locations dT (K) Max. dT (K)
EGO / EIKA
Supply cord (T90) 39 / 39 65
X2 capacitor (T110) 36 / 37 85
Transformer 38 / 39 65
Relay (LNH33012) 48 / 50 65
PCB 36 / 38 120
Internal wire 100 / 116 175
Test corner, under side place 18 / 17 65
Bottom metal plate 53 / 53 Ref. only

TRF No. IEC60335_2_6J


Page 90 of 118 Report No:247713

IEC 60335-2-6

(14.) TYPE P58…… MODEL EO6900 with new PCB control unit and new heating element
PCB control unit: EIKA _ BH3715360111xx
Heating element: EGO _ 10.51311.xxx / EIKA _ 2302734932
Test voltage (V) .................................................... : 261V (8,64kW) 
Ambient (C) ......................................................... : 19 
Thermocouple locations dT (K) Max. dT (K)
Supply cord (T90) 63 65
Rast T. Block (T125) 79 100
Thermostat (T250) 123 225
Internal wirings (T200) 109 175
Faston cover (Relay R1) 58 Cfr. Cl.30
Coil relay R1 (cl.155/F) 65 115
Transformer (SMPS, T1) 51 65
PCB 58 120
X2 capacitor (T110) 53 85
Plastic conduit 93 Cfr. Cl.30
Touch control zone 30 45
Wood in general 53 70

(15.) TYPE P58…… MODEL EC6700 with new alt. heating element and slim dimension
PCB control unit: EIKA _ BH3715360111xx
Heating element: EGO _ 10.57413.624
Test voltage (V) .................................................... : 262V (8,4kW) 
Ambient (C) ......................................................... : 20 
Thermocouple locations dT (K) Max. dT (K)
Supply cord (T90) 53 65
Rast T. Block (T125) 80 100
Internal wirings (T200) 124 175
Wooden frame back 57 70
Wooden frame side 47 70

TRF No. IEC60335_2_6J


Page 91 of 118 Report No:247713

IEC 60335-2-6

(16.) TYPE P58…… MODEL EC5400 with slim dimension


PCB control unit: EIKA _ BH3715360111xx
Heating element: EGO _ 10.52213.044
Test voltage (V) .................................................... : 262V (6,77kW) 
Ambient (C) ......................................................... : 24 
Thermocouple locations dT (K) Max. dT (K)
Wooden frame back 50 70
Wooden floor 21 70
Wooden frame side 32 70

(17.) TYPE P58…… MODEL EO6400 with PCB control unit: EIKA _ BN34D36211107

Test voltage (V) .................................................... : 262V (8022W) 


Ambient (C) ......................................................... : 19 
Thermocouple locations dT (K) Max. dT (K)
2
Supply cord (3G2,5mm ) (T90) 50 65
Terminal block 56 65
Relay R3 59 Cfr.cl.30
Capacitor C11 (T105) 51 80
Capacitor C12 (T105) 56 80
Inductor L3 59 80
PCB (T105) 48 80
Internal wire (T200) 98 175
Wooden frame side 35 70
Wooden frame rear 57 70
Wooden bottom plate 23 70

TRF No. IEC60335_2_6J


Page 92 of 118 Report No:247713

IEC 60335-2-6

11.8 TABLE: Heating test, resistance method P


Test voltage (V) .................................................... : Various 
Ambient, t1 (C) ..................................................... : See below 
Ambient, t2 (C) ..................................................... : See below 
Temperature rise of winding R1 (Ω) R2 (Ω) dT (K) Max. dT (K) Insulation
class
Transformer ZAREL Code: 003179675 00321004 (On EIKA Electronic board) 8A 1..0 360….. or
8B.1..0 360…..
Primary (t1=23.5 t2=23.5) 830 998 52 115 Class 155(F)
Secondary (t1=23.5 t2=23.5) 3.690 4.580 62 115 Class 155(F)

Transformer KASCHKE Code: 451 761 (On DIEHL Electronic board)


Primary (t1=23.7 t2=23.7) 3.963 4.830 57 75 Class 105(A)
Secondary (t1=23.7 t2=23.7) 0.101 0.128 69 75 Class 105(A)

Relay Schrack LNH30012


Winding (t1=23.5 t2=23.5) 337 405 52 75 Class 105(A)

Transformer Mencarini TRP 01


Primary (t1=23,0, t2=23,0) 714,3 903,0 68 95 Class 130(B)
Secondary (t1=23,0, t2=23,0) 7,42 9,13 59 95 Class 130(B)

Transformer ERA BV 030-…


Primary 1 (t1=22,0, t2=22,0) 354,6 420,1 47 95 Class 130(B)
Primary 2 (t1=22,0, t2=22,0) 354,9 423,3 49 95 Class 130(B)
Secondary 1 (t1=22,0, t2=22,0) 4,615 5,494 49 95 Class 130(B)
Secondary 2 (t1=22,0, t2=22,0) 4,611 5,440 46 95 Class 130(B)

Coil of relay schrack RT31… 364,6 436,8 51 75 Class 105(A)


(t1=23,0, t2=23,0)
Coil of relay Matsushita JS1… 395,8 440,4 29 75 Class 105(A)
(t1=23,0, t2=23,0)

Transformer Marschner FLG30…,


Primary 1 (t1=22,0, t2=22,0) 310,8 379,4 57 115 Class 155(F)
Primary 2 (t1=22,0, t2=22,0) 308,0 378,1 58 115 Class 155(F)
Secondary (t1=22,0, t2=22,0) 5,73 6,92 53 115 Class 155(F)

TRF No. IEC60335_2_6J


Page 93 of 118 Report No:247713

IEC 60335-2-6

Transformer STEGER 08-1120


Primary (t1=22.5 t2=22.5) 1043 1310 66 115 Class 155(F)
Secondary (t1=22.5 t2=24.0) 3.38 4.144 57 115 Class 155(F)

Relay, NAIS JS1a-B-6V-H150


Winding (t1=22.5 t2=22.5) 96.6 117.1 55 75 Class 105(A)

Transformer ZAREL 2604


Primary (t1=25 t2=21.5) 748 927 66 115 Class 155(F)
Secondary (t1=25 t2=21.5) 3.438 4.190 60 115 Class 155(F)

Relay, Schrack LNH30012


Winding (t1=25 t2=21.5) 340 400 49 75 Class 105(A)

Transformer Avisor EI42/14,5,


Primary (t1=20,5, t2=21,0) 790,1 932,4 45 95 Class 130(B)
Secondary (t1=20,5, t2=21,0) 2,015 2,376 45 95 Class 130(B)

Coil of Relay OMRON G2RL… 361,0 428,3 47 75 Class 105(A)


(t1=20,5, t2=21,0)

Coil of Relay Carlo Gavazzi 357,6 431,3 52 95 Class 130(B)


M25… (t1=22,5, t2=23,0)

Coil of Relay Schrack LNH33006 84.01 99.93 48 75 Class 105(A)


t1=20,0, t2=20,0)

Coil of Relay Schrack RFH34006 85.99 99.42 40 75 Class 105(A)


t1=20,0, t2=20,0)

Transformer ERA Type UI30/10.5 BV 030-7863 0


Primary (t1=22,0, t2=22,0) 629.8 813.0 75 115 Class 155(F)
Secondary (t1=22,0, t2=22,0) 3.129 3.967 69 115 Class 155(F)

Transformer Kaschke 063.682

TRF No. IEC60335_2_6J


Page 94 of 118 Report No:247713

IEC 60335-2-6

Primary (t1=19,0, t2=21,0) 3.965 5.167 75 95 Class 130(B)


Secondary (t1=19,0, t2=21,0) 0.0284 0.037 73 95 Class 130(B)

Coil of Relay Finder 96.84 126.26 59 115 Class 155(F)


45.71.7.006.0300
(t1=19,0, t2=21,0)

11.101 TABLE: Temperature rise limits for accessible surfaces specifications N/A
test step n°/ function temperature duration

11.101 TABLE: Temperature rise limits for accessible front and side surfaces N/A
dT (K) Max. dT (K)
Front surfaces of oven doors  
Test step n. 
Ambient (°C) 
Metal and painted metal 45
Vitreous-enamelled metal 50
Glass and ceramic 60
Plastic having a thickness exceeding 0,3mm 80
Other accessible front and side surfaces 
(or surfaces above 850 mm)
Test step n. 
Ambient (°C) 
Metal and painted metal 60
Vitreous-enamelled metal 65
Glass and ceramic 80
Plastic having a thickness exceeding 0,3mm 100

TRF No. IEC60335_2_6J


Page 95 of 118 Report No:247713

IEC 60335-2-6

13.2 TABLE: Leakage current P


Heating appliances: 1.15 x rated input .................. : P = 1,15 * (240/230)² * Pr 
Motor-operated and combined appliances: 
1.06 x rated voltage................................................ :
Leakage current between I (mA) Max. allowed I (mA)
Any pole of supply and accessible metal parts Max.1,2 Min.5,1
Between live parts and each of the vessels Max. 0,04 0.25

13.3 TABLE: Electric strength P


Test voltage applied between: Voltage (V) Breakdown
(Yes/No)
Live parts and accessible metal parts (basic insulation) 1000V No
Live parts and the vessels connected together 3000V No
Live parts and non earthed accessible touchable parts (control 3000V No
panel)

14 TABLE: Transient overvoltages N/A


Clearance between: Cl (mm) Required Rated impulse Impulse test Flashover
Cl (mm) voltage (V) voltage (V) (Yes/No)

16.2 TABLE: Leakage current P


Single phase appliances: 1.06 x rated voltage ...... : 254,4V 
Three phase appliances 1.06 x rated voltage 254,4V 
divided by 3: ......................................................... :
Leakage current between I (mA) Max. allowed I (mA)
Any pole of supply and accessible metal parts Max. 1,4 Min. 5,1
Between live parts and each of the vessels Max. 0,1 0.25

16.3 TABLE: Electric strength P


Test voltage applied between: Voltage (V) Breakdown
(Yes/No)
Live parts and accessible metal parts (basic insulation) 1250 No
Live parts and the vessels electrically connected together 3000 No
Live parts and non earthed accessible touchable parts (control 3000 No
panel)

TRF No. IEC60335_2_6J


Page 96 of 118 Report No:247713

IEC 60335-2-6

17 TABLE: Overload protection, temperature rise N/A


Temperature rise of part/at: dT (K) Max. dT (K)

19.7 TABLE: Abnormal operation, locked rotor/moving parts N/A


Test voltage (V)........................................................ : 
Ambient, t1 (C) ........................................................ : 
Ambient, t2 (C) ........................................................ : 
Temperature of winding R1 (Ω) R2 (Ω) dT (K) T (C) Max. T (°C)

19.11 TABLE: Fault conditions P


Test voltage (V) .................................................... : 240V 
Ambient, t1 (C) ......................................................: 20 
Ambient, t2 (C) ......................................................: 20 
Fault Component OC / Operating condition Remarks
No. SC
1 Electrolytic capacitor C1 (Diehl OC Not possible to switch on the No hazard
electronic board TC-4SE-Z-XX- appliance
SC
YY-105-U230)
2 Electrolytic capacitor C2 (Diehl OC Not possible to switch on the No hazard
electronic board TC-4SE-Z-XX- appliance
SC
YY-105-U230)
3 Electrolytic capacitor C1 (Eika OC Not possible to switch on the No hazard
electronic board 8A 1..0 360….. SC
appliance
or 8B.1..0 360…..)
4 Electrolytic capacitor C2 (Eika OC Not possible to switch on the No hazard
electronic board 8A 1..0 360….. SC
appliance
or 8B.1..0 360…..)
5 Electrolytic capacitor C3 (Eika OC Not possible to switch on the No hazard
electronic board 8A 1..0 360….. SC
appliance
or 8B.1..0 360…..)
6 10nF electrolytic capacitor OC Not possible to switch on the No hazard
(Diehl electronic board TC3-Q- appliance
SC
9T-4R-U230)
7 X2 100nF Capacitor on DIEHL OC Not possible to switch on the No hazard
electronic board TC4 Standard appliance
H
8 R=33Ω on DIEHL electronic OC Not possible to switch on the No hazard
board TC4 Standard H appliance
SC The appliance operates as
intended

TRF No. IEC60335_2_6J


Page 97 of 118 Report No:247713

IEC 60335-2-6

9 100nF 400V electrolytic OC Not possible to switch on the No hazard


capacitor on DIEHL electronic appliance
SC
board TC4 Standard H
10 330μF 25V electrolytic capacitor OC Not possible to switch on the No hazard
on DIEHL electronic board TC4 appliance
SC
Standard H
Note : No component to be submitted to fault condition on EGO electronic board 75.13061.201 (4 relays) or
75.13061.202 (5 relays)

19.13 TABLE: Abnormal operation, temperature rise, resistance method. P


Test voltage (V)........................................................ : 240/ Various 
Ambient, t1 (C) ....................................................... : Various 
Ambient, t2 (C) ....................................................... : Various 
Temperature of winding R1 (Ω) R2 (Ω) dT (K) T (C) Max. T (°C)

Transformer STEGER 08-112


Primary (t1=22.5 t2=25) 1043 1628 142 167 190
Secondary (t1=22.5 t2=25) 3.38 5.327 146 171 190

Relay, JS1a-B-6V-H150
Winding (t1=22.5 t2=24.5) 96.6 131.7 91 116 150

Transformer ZAREL 2604


Primary (t1=25 t2=25) 748 1135 134 159 240
Secondary (t1=25 t2=25) 3.438 5.317 142 167 240

Relay, LNH30012
Winding (t1=25 t2=23.5) 340 428 69 93 150

Transformer FLG30
Primary 1 (t1=22,0, t2=22,5) 310,8 424,4 93 116 190
Primary 2 (t1=22,0, t2=22,5) 308,0 422,3 95 117 190
Secondary (t1=22,0, t2=22,5) 5,73 7,75 90 112 190

Transformer TRP 01
Primary (t1=23,0, t2=23,0) 714,3 1084,5 133 156 175
Secondary (t1=23,0, t2=23,0) 7,42 10,14 94 117 175

Transformer BV 030-…
Primary 1 (t1=22,0, t2=21,0) 354,6 472,5 86 107 175

TRF No. IEC60335_2_6J


Page 98 of 118 Report No:247713

IEC 60335-2-6

Primary 2 (t1=22,0, t2=21,0) 354,9 471,3 85 106 175


Secondary 1 (t1=22,0, t2=21,0) 4,615 6,135 85 106 175
Secondary 2 (t1=22,0, t2=21,0) 4,611 6,069 82 103 175

Transformer EI42/14,5
Primary (t1=20,5, t2=22,0) 790,1 1013,8 71 93 175
Secondary (t1=20,5, t2=22,0) 2,015 2,602 73 95 175

Coil of relay RT31…(t1=23,0, 364,6 479,0 81 104 150


t2=23,0)
Coil of relay JS1… (t1=23,0, 395,8 478,7 54 77 150
t2=23,0)

Coil of relay, S5 100… (t1=22,0, 394,6 472,6 50 73 210


t2=22,5)

Coil of Relay G2RL… (t1=20,5, 364,2 458,4 64 86 150


t2=22,0)

Coil of Relay M25… (t1=22,5, 357,6 446,3 64 86 175


t2=22,5)

Transformer ZAREL
Code: 003179675 00321004
Class F
(On EIKA Electronic board)
(at 267V)
Primary (t1=23.5 t2=23.5) 830 1340 159 183 190
Secondary (t1=23.5 t2=23.5) 3.690 5.660 153 177 190

Relay, LNH30012 (supposed as


class A) (at 267V)
Winding (t1=23.5 t2=23.5) 337 430 71 95 150

Transformer KASCHKE
Code: 451 761
(supposed as class A)
(On DIEHL Electronic board)
(at 267V)
Primary (t1=23.5 t2=23.5) 3.963 5.48 99 123 150
Secondary (t1=23.5 t2=23.5) 0.101 0.137 96 120 150

03100 Coil winding (Class E) __ __ __ 79 215


(at 268V)
(termocouple metod used)

TRF No. IEC60335_2_6J


Page 99 of 118 Report No:247713

IEC 60335-2-6

19.13 TABLE: Abnormal operation, temperature rises P


Thermocouple locations dT (K) Max. dT (K)
Supply cord 113 150
Test corner, floor 79 150
Test corner, built-in frame 123 150
Test corner, walls 146 150
Bottom plate of the appliance, against the 94 150
floor of the test corner

24.1 TABLE: Components P


Object / part No. Manufacturer/ Type / model Technical data Standard Mark(s) of
trademark conformity
2
Supply cord Various H05V2V2-F 3 x 2,5mm HD21 <HAR>
2
Alt. Various H05RR-F 3 x 2,5mm HD22 <HAR>
2
Alt. Various H05BB-F 3 x 2,5mm HD22 <HAR>
2 1)
Terminal Electro-Terminal EKL 2 EF 450V 6mm IECEN 60998-1 VDE , N, S,
1)
(P58EO,EV,RO, IECEN 60998-2-1 D, FI, IMQ ,
RV,MO,MV,CO,
CV)
2
Alt. Electro-Terminal BEKL3 450V 6mm IECEN 60998-1 VDE, ÖVE,
1)
(P58RO,RV,MO IECEN 60998-2-1 IMQ
,MV)
2
Alt. Electro-Terminal KADO 2/5 450V 24A 2,5mm IECEN 60998-1 VDE
(P58EO,EV,RO, IECEN 60998-2-1
RV,MO,MV,CO,
CV)
Alt. Electro-Terminal ESKLG21ST 450V 16° IECEN 60998-1 VDE
(P58RE,RB,ME, IECEN 60998-2-1
MB, CE,CB)
Alt. Electro-Terminal ESKL2 400 V 16° – 6 mm IECEN 60998-1 VDE
(P58RE,RB,ME, IECEN 60998-2-1
MB,CE,CB)
1)
Alt. Metalluk 102 400V 16° IECEN 60998-1 VDE
(P58RO,RV,MO IECEN 60998-2-1
,MV)
1)
Alt. Metalluk 119 400V 16° IECEN 60998-1 VDE
(P58RO,RV,MO IECEN 60998-2-1
,MV)
1)
Alt. Metalluk 137 450V 6mm2 IECEN 60998-1 VDE
(P58RO,RV,MO IECEN 60998-2-1
,MV)

TRF No. IEC60335_2_6J


Page 100 of 118 Report No:247713

IEC 60335-2-6

Alternative NECTO AD 030 T 2,5 – 6mm² IECEN 60998-1 IMQ


terminal IECEN 60998-2-1

Residual heat Tecnowind SVA461A - IECEN 60335-1 Tested in


lamp IECEN 60335-2-6 appliance
For all the Models
Heating element Ceramaspeed 120N8-L****# 600W 230V IECEN 60335-1 VDE Tested
front left or back * 100mm HL type IECEN 60335-2-6 in the
right appliance
Heating element EIKA Q) 12020.....*) 600W 230V~ IECEN 60335-1 VDE Tested
front left or back 100mm IECEN 60335-2-6 in the
right (a) appliance
For Model E.…. / Model R….. / Model M…..
Heating element Ceramaspeed 200N7-L……. 1800W 230V IECEN 60335-1 VDE Tested
front left or back 180mm HL type IECEN 60335-2-6 in the
right appliance
Alt. EGO 10.58111.xxx 1800W 230V IECEN 60335-1 VDE Tested
180mm HL type IECEN 60335-2-6 in appliance
Alt. Ceramaspeed 200N8L6699D 1800W 230-240V IECEN 60335-1 VDE Tested
180mm HL type IECEN 60335-2-6 in appliance
Alt. EIKA 2002032932 1800W 230-240V IECEN 60335-1 VDE Tested
180mm HL type IECEN 60335-2-6 in appliance
Alt. Ceramaspeed 190V8L6696D 2200/1400W 230V IECEN 60335-1 VDE Tested
IECEN 60335-2-6 in appliance
Alt. EIKA 2852433832 2200/1400W 230V IECEN 60335-1 VDE Tested
IECEN 60335-2-6 in appliance
Alt. EGO 10.57413.xxx 2200/1400W 230V IECEN 60335-1 VDE Tested
IECEN 60335-2-6 in appliance
Alt. EGO 10.58211.xxx 1800W 230-240V IECEN 60335-1 VDE Tested
180mm HL type IECEN 60335-2-6 in the
appliance
Alt. Ceramaspeed 200N8L6698D 1800W 230-240V IECEN 60335-1 VDE Tested
180mm HL type IECEN 60335-2-6 in the
appliance
Alt. EIKA 2002032832 1800W 230-240V IECEN 60335-1 VDE Tested
180mm HL type IECEN 60335-2-6 in the
appliance
Alt. Ceramaspeed 200H8N8688 1700W 230-240V IECEN 60335-1 Tested in
D 180mm HAL type IECEN 60335-2-6 the
appliance
Alt. EIKA 2001032832 1700W 230-240V IECEN 60335-1 VDE Tested
180mm HAL type IECEN 60335-2-6 in the
appliance
Alt. EGO 10.98501.xxx 1800W 230-240V IECEN 60335-1 VDE Tested
180mm HAL type IECEN 60335-2-6 in the
appliance
Alt. EGO 10.78631.xxx 1700W 230-240V IECEN 60335-1 VDE Tested
180mm RM type IECEN 60335-2-6 in the
appliance

TRF No. IEC60335_2_6J


Page 101 of 118 Report No:247713

IEC 60335-2-6

Alt. EGO 10.88631.xxx 1700W 230-240V IECEN 60335-1 Tested in


180mm RM type IECEN 60335-2-6 the
appliance
Alt. Ceramaspeed 200N57479LY 1700W 230-240V IECEN 60335-1 Tested in
20336Y 180mm RM type IECEN 60335-2-6 the
appliance
Alt. EIKA 2000632832 1700W 230-240V IECEN 60335-1 VDE Tested
180mm RM type IECEN 60335-2-6 in the
appliance
Alt. EIKA 2000632932 1700W 230-240V IECEN 60335-1 VDE Tested
180mm RM type IECEN 60335-2-6 in the
appliance
Alt. EGO 10.58211.xxx 1700/600W 230V IECEN 60335-1 VDE Tested
100/180mm HL IECEN 60335-2-6 in the
type appliance
Alt. EGO 10.58211.xxx 1700/750W 230V IECEN 60335-1 VDE Tested
120/180mm HL IECEN 60335-2-6 in the
type appliance
Alt. Ceramaspeed 200T8L6705D 1700/750W 230V IECEN 60335-1 VDE Tested
120/180mm HL IECEN 60335-2-6 in the
type appliance
Alt. EGO 10.58213.xxx 1700/700W 230V IEC/EN 60335-1 Tested in
120/180mm IEC/EN 60335-2- appliance
6 VDE
For Model E.…. / Model R….. / Model M….. (Except for models EO5100, EO5200, EO5300 and
EO5410)
Alt. Heating Ceramaspeed 230T8L6703D 2100/700W 230V IECEN 60335-1 VDE Tested
element front 120/210mm HL IECEN 60335-2-6 in the
left or back right type appliance
Alt. EIKA 2302333932 2100/700W 230V IECEN 60335-1 VDE Tested
120/210mm HL IECEN 60335-2-6 in the
type appliance
Alt. Ceramaspeed 230T8L5625D 2100/700W 230V IECEN 60335-1 VDE Tested
120/180mm HL IECEN 60335-2-6 in the
type appliance
Alt. EIKA 2302333832 2100/700W 230V IECEN 60335-1 VDE Tested
120/210mm HL IECEN 60335-2-6 in the
type appliance
Alt. EGO 10.51211.xxx 2100/700W 230V IECEN 60335-1 VDE Tested
120/210mm HL IECEN 60335-2-6 in the
type appliance
Alt. Ceramaspeed 230T8L5625D 2200/1000W IECEN 60335-1 VDE Tested
230V IECEN 60335-2-6 in the
140/210mm HL appliance
type
Alt. EIKA 2312333832 2200/1000W IECEN 60335-1 VDE Tested
230V IECEN 60335-2-6 in the
140/210mm HL appliance
type
Alt. EGO 10.51211.xxx 2200/1000W IECEN 60335-1 VDE Tested
230V IECEN 60335-2-6 in the
140/210mm HL appliance
type

TRF No. IEC60335_2_6J


Page 102 of 118 Report No:247713

IEC 60335-2-6

Alt. Ceramaspeed 230N8L6701D 2200W 220-240V IECEN 60335-1 VDE Tested


210mm HL type IECEN 60335-2-6 in the
appliance
Alt. EIKA 2302032932 2200W 220-240V IECEN 60335-1 VDE Tested
210mm HL type IECEN 60335-2-6 in the
appliance
Alt. EIKA 2302032832 2200W 220-240V IECEN 60335-1 VDE Tested
210mm HL type IECEN 60335-2-6 in the
appliance
Alt. EGO 10.51111.xxx 2200W 220-240V IECEN 60335-1 VDE Tested
210mm HL type IECEN 60335-2-6 in the
appliance
Alt. EGO 10.81631.xxx 2100W 230-240V IECEN 60335-1 Tested in
210mm RM type IECEN 60335-2-6 the
appliance
Alt. EIKA 2300632932 2100W 220-240V IECEN 60335-1 VDE Tested
210mm RM type IECEN 60335-2-6 in the
appliance
Alt. EIKA 2300632832 2100W 230-240V IECEN 60335-1 VDE Tested
210mm RM type IECEN 60335-2-6 in the
appliance
Alt. EGO 10.71631.xxx 2100W 230-240V IECEN 60335-1 VDE Tested
210mm RM type IECEN 60335-2-6 in the
appliance
For Model M….. / Model C…..
Alt. Heating Ceramaspeed 200M58750L 1700W 230-240V IECEN 60335-1 Tested in
element front 180mm RT type IECEN 60335-2-6 the
left or back right appliance
Alt. EIKA 2000734832 1700W 230-240V IECEN 60335-1 VDE Tested
180mm RT type IECEN 60335-2-6 in the
appliance
Alt. EGO 10.78431.xxx 1700W 230-240V IECEN 60335-1 Tested in
180mm RT type IECEN 60335-2-6 the
appliance
Alt. EGO 10.71431.xxx 2100W 230-240V IECEN 60335-1 Tested in
210mm RT type IECEN 60335-2-6 the
appliance
Alt. EIKA 2300734832 2100W 230-240V IECEN 60335-1 VDE Tested
210mm RT type IECEN 60335-2-6 in the
appliance
Alt. Ceramaspeed 230M58751L 2100W 220-450V IECEN 60335-1 Tested in
210mm RT type IECEN 60335-2-6 the
appliance
For Model E.…. / Model R….. / Model M…..
Heating element EIKA 1652032832 1000W 230V IECEN 60335-1 VDE Tested
back left or front 145mm HL type IECEN 60335-2-6 in the
right appliance
Alt. EGO 10.54111.xxx 1000W 230V IECEN 60335-1 VDE Tested
145mm HL type IECEN 60335-2-6 in the
appliance
Alt. EIKA 1652032832 1000W 230V IECEN 60335-1 VDE Tested
145mm HL type IECEN 60335-2-6 in the
appliance

TRF No. IEC60335_2_6J


Page 103 of 118 Report No:247713

IEC 60335-2-6

Alt. Ceramaspeed 165N7-L……. 1200W 230V IECEN 60335-1 VDE Tested


145mm HL type IECEN 60335-2-6 in the
appliance
Alt. Ceramaspeed 165N8L6695D 1200W 230V IECEN 60335-1 VDE Tested
145mm HL type IECEN 60335-2-6 in the
appliance
Alt. EIKA 1652032932 1200W 230V IECEN 60335-1 VDE Tested
145mm HL type IECEN 60335-2-6 in the
appliance
Alt. EIKA 1652032832 1200W 230V IECEN 60335-1 VDE Tested
145mm HL type IECEN 60335-2-6 in the
appliance
Alt. Ceramaspeed 165N8L6694D 1200W 230V IECEN 60335-1 VDE Tested
145mm HL type IECEN 60335-2-6 in the
appliance
Alt. EGO 10.54111.xxx 1200W 230V IECEN 60335-1 VDE Tested
145mm HL type IECEN 60335-2-6 in the
appliance
Alt. Ceramaspeed 165H8N8687 1200W 230V IECEN 60335-1 VDE Tested
D 145mm HAL type IECEN 60335-2-6 in the
appliance
Alt. EIKA 1651032832 1200W 230V IECEN 60335-1 VDE Tested
145mm HAL type IECEN 60335-2-6 in the
appliance
Alt. EGO 10.94501.xxx 1200W 230V IECEN 60335-1 VDE Tested
145mm HAL type IECEN 60335-2-6 in the
appliance
Alt. EIKA 1650632932 1200W 230V IECEN 60335-1 VDE Tested
145mm RM type IECEN 60335-2-6 in the
appliance
Alt. EIKA 1650632832 1200W 230V IECEN 60335-1 VDE Tested
145mm RM type IECEN 60335-2-6 in the
appliance
Alt. EGO 10.74631.xxx 1200W 230V IECEN 60335-1 VDE Tested
145mm RM type IECEN 60335-2-6 in the
appliance
Alt. heating E.G.O. 930REHL146 230V ~ 1200W IECEN 60335-1 Tested in
element hob 2 0000 Ø 145mm IECEN 60335-2-6 appliance
(10.54114.xxx) VDE
For Model M….. / Model C…..
Heating element Ceramaspeed 165M58749L 1200W 230V IECEN 60335-1 Tested in
back left or front 145mm RT type IECEN 60335-2-6 the
right (a) appliance
Heating element EIKA 1650734832 1200W 230V IECEN 60335-1 VDE Tested
back left or front 145mm RT type IECEN 60335-2-6 in the
right (a) appliance
Heating element EGO 10.74431.xxx 1200W 230V IECEN 60335-1 Tested in
back left or front 145mm RT type IECEN 60335-2-6 the
right (a) appliance
Alt. heating E.G.O. 930REHL146 230V ~ 1200W IECEN 60335-1 Tested in
element hob 2 0000 Ø 145mm IECEN 60335-2-6 appliance
(10.54114.xxx) VDE

TRF No. IEC60335_2_6J


Page 104 of 118 Report No:247713

IEC 60335-2-6

For Model E….. / R….. / Model M….. (Except for Models EO5100, EO5200, EO5300 and EO5410)
Heating element EGO 10.57411.xxx 1800/1000W IECEN 60335-1 VDE Tested
back left (a) 230V IECEN 60335-2-6 in the
145/250mm HL appliance
type
Alt. Ceramaspeed 165V8L6831D 1800/1000W IECEN 60335-1 VDE Tested
230V IECEN 60335-2-6 in the
145/250mm HL appliance
type
Alt. EIKA 2702433832 1800/1000W IECEN 60335-1 VDE Tested
230V IECEN 60335-2-6 in the
145/250mm HL appliance
type
Alt. EGO 10.57411.xxx 1800/1000W 230V IECEN 60335-1 VDE Tested
145/250mm HL IECEN 60335-2-6 in the
type appliance
For Model RE…. / RB….
Heating element Ceramaspeed 190V8L6696D 2200/1400W 230V IECEN 60335-1 VDE Tested
back left (a) 170/265mm HL IECEN 60335-2-6 in appliance
type
Alt. Ceramaspeed 190V8L6696D 2200/1400W 230V IECEN 60335-1 VDE Tested
170/265mm HL IECEN 60335-2-6 in appliance
type
Alt. EIKA 2852433832 2200/1400W 230V IECEN 60335-1 VDE Tested
170/265mm HL IECEN 60335-2-6 in appliance
type
Alt. EGO 10.57413.xxx 2200/1400W 230V IECEN 60335-1 VDE Tested
IECEN 60335-2-6 in appliance
For Model EO5100, EO5200, EO5300 and EO5410
Alt. Heating Ceramaspeed 300T8L8343D 2400/1500W IECEN 60335-1 VDE Tested
element back 230V IECEN 60335-2-6 in the
left (a) 275/210mm HL appliance
type
For Model EO6400, EO6900
Heating element 10.51311.xxx EGO 230V 50/60Hz IEC/EN 60335-1 VDE
front left 2300/1600/800W IEC/EN 60335-2-6 Tested in
appliance
Alt. Heating 2302734932 Eika 230V 50/60Hz IEC/EN 60335-1 VDE
element front 23001600/800W IEC/EN 60335-2-6 Tested in
left (a) appliance
For Model E….. / R….. / M….. / C…..
1))
Thermostat for Electrovac Z98 12°/250V 8°/400V IECEN 60730-1 VDE
heating T250 IECEN 60730-2-1
elements IECEN 60730-2-9
1))
Thermostat for EGO 60.25171.003 12° 250V 8° 400V IECEN 60730-1 VDE
heating T250 IECEN 60730-2-1
elements (a) IECEN 60730-2-9

TRF No. IEC60335_2_6J


Page 105 of 118 Report No:247713

IEC 60335-2-6

1)
Thermostat for Electrovac Z82 12°/250V 7°/400V IECEN 60730-1 VDE
heating T250 IECEN 60730-2-1
elements (a) IECEN 60730-2-9
1)
Thermostat for Electrovac Z95 12° 250V 8° 400V IECEN 60730-1 VDE
heating T250 IECEN 60730-2-1
elements (a) IECEN 60730-2-9
1)
Thermostat for EIKA TH0xxxxx 12° 250V 8° 400V IECEN 60730-1 VDE
heating T250 IECEN 60730-2-1
elements (a) IECEN 60730-2-9
Thermostat for Electrovac Z15 12° 250V 8° 400V IECEN 60730-1 ENEC 10,
1)
heating T250 IECEN 60730-2-1 VDE
elements (a) IECEN 60730-2-9
Thermostat for Electrovac Z16 12° 250V 8° 400V IECEN 60730-1 Tested with
heating T250 IECEN 60730-2-1 component
elements (a) IECEN 60730-2-9 standard
Test report
CTI-CB 598-
1 by CTI-
Vienna
For Model R….. / M…..
1)
Energy Siebe Appliance MSA V03 15A 240V T125 IECEN 60730-1 BEAB ,
)
regulators, Controls IECEN 60730-2- VDE
single zone (Invensys) 11
1)
Energy Siebe Appliance MSA V01 15A 240V T125 IECEN 60730-1 BEAB ,
1)
regulators (a) Controls IECEN 60730-2- KEMA
(Invensys) 11
13A 230V  freq.
1)
Energy EGO 50.57021.010 IECEN 60730-1 VDE , N, S,
regulators (a) Op. T125 IECEN 60730-2- D, FI, IMQ,
(the component 11 KEMA, ÖVE
has been
separately tested
for 240/400V
13A 230V  T125
1)
Energy EGO 50.55021.100 IECEN 60730-1 VDE , N, S,
regulators (a) (the component IECEN 60730-2- D, FI, IMQ,
has been 11 KEMA, ÖVE
separately tested
for 240/400V
Energy EGO 50.75021.000 230V 13A T125 IECEN 60730-1 VDE
regulators (a) IECEN 60730-2-
11
Energy EGO 50.77021.000 230V 13A T125 IECEN 60730-1 VDE
regulators (a) IECEN 60730-2-
11
13A 230V  T125
1)
Energy EGO 50.57071.041 IECEN 60730-1 VDE , N, S,
regulators (a) (the component IECEN 60730-2- D, FI, IMQ,
has been 11 KEMA, ÖVE
separately tested
for 240/400V

TRF No. IEC60335_2_6J


Page 106 of 118 Report No:247713

IEC 60335-2-6

13A 230V  T125


1)
Energy EGO 50.55021.104 IECEN 60730-1 VDE , N, S,
regulators (a) (the component IECEN 60730-2- D, FI, IMQ,
has been 11 KEMA, ÖVE
separately tested
for 240/400V
For Model MO…. / MV…. / CO…. / CV….
1)
Commutator EGO 46.27266.500 16 A 250V – 10A IECEN 61058-1 VDE
400V (PD 58 –
WITH CARDAN
JOINT)
1)
Commutator (a) EGO 41.41723.005 16 A 250V – 10A IECEN 61058-1 VDE
400V (PD 58 –
WITH CARDAN
JOINT)
1)
Commutator (a) EGO 41.44723.006 16 A 250V – 10A IECEN 61058-1 VDE
400V (PD 58 –
WITH CARDAN
JOINT)
Commutator (a) EGO Serie 41.4.---.- 250/400V~ 10A IEC/EN 61058-1 VDE
-- T140
Commutator (a) Dreefs TypeE/01- 12 A – 250V - IECEN 60335-1 Tested in
0508 400V T125 (PD 29- IECEN 60335-2-6 appliance
CARDAN JOINT) + Annex H
Power and control PCB
1)
Power PCB EGO 75.13020.303 - IECEN 60730-2-1 VDE
IECEN 60335-1 Tested in
IECEN 60335-2-6 appliance
1)
Power PCB (a) EGO 75.13020.302 - IECEN 60730-2-1 VDE
IECEN 60335-1 Tested in
IECEN 60335-2-6 appliance
1)
Power PCB (a) EGO 75.13061.201 4 relays IECEN 60730-2-1 VDE
IECEN 60335-1 Tested in
IECEN 60335-2-6 appliance
1)
Power PCB (a) EGO 75.13061.202 5 relays IECEN 60730-2-1 VDE
IECEN 60335-1 Tested in
IECEN 60335-2-6 appliance
Power PCB (a) DDS DDS218 - IECEN 60335-1 Tested in
IECEN 60335-2-6 appliance
1)
Power PCB (a) DIEHL TC3-Q-9T-4R- - IECEN 60730-2-1 VDE
U230 IECEN 60335-1 Tested in
IECEN 60335-2-6 appliance
Power PCB (a) DDS DDS151REL IECEN 60335-1 Tested in
IECEN 60335-2-6 appliance
1)
Power PCB (a) DDS DDS151B - IECEN 60730-2-1 VDE
IECEN 60335-1 Tested in
IECEN 60335-2-6 appliance
Power PCB (a) PGA 9901R2,1 - IECEN 60335-1 Tested in
IECEN 60335-2-6 appliance
Power PCB (a) PGA 9901 - IECEN 60335-1 Tested in
IECEN 60335-2-6 appliance
1)
Power PCB (a) DIEHL 704455 - IECEN 60730-2-1 VDE
IECEN 60335-1 Tested in
IECEN 60335-2-6 appliance

TRF No. IEC60335_2_6J


Page 107 of 118 Report No:247713

IEC 60335-2-6

Power PCB (a) DIEHL TC4 SE - IECEN 60335-1 Tested in


13704-014 IECEN 60335-2-6 appliance
Power PCB (a) DIEHL TC4 SE - IECEN 60335-1 Tested in
13704-080 IECEN 60335-2-6 appliance
Power PCB (a) DIEHL 701449 - IECEN 60335-1 Tested in
IECEN 60335-2-6 appliance
Power PCB (a) EIKA 87140036010 - IECEN 60335-1 Tested in
011 IECEN 60335-2-6 appliance
Power PCB (a) EIKA 86140036010 - IECEN 60335-1 Tested in
011 IECEN 60335-2-6 appliance
Power PCB (a) EIKA 8A 1..0 230V 50/60Hz IECEN 60335-1 VDE Tested
360….. T105 IECEN 60335-2-6 in appliance
Power PCB (a) EIKA 8B.1..0 230V 50/60Hz IECEN 60335-1 VDE Tested
360….. T105 IECEN 60335-2-6 in appliance
Control PCB PGA 9922 - IECEN 60335-1 Tested in
IECEN 60335-2-6 appliance
Control PCB (a) PGA 9920 - IECEN 60335-1 Tested in
IECEN 60335-2-6 appliance
Control PCB (a) EGO 75.13022.102 - IECEN 60335-1 Tested in
IECEN 60335-2-6 appliance
Control PCB (a) Eika BJ3xxA36211 208-240VAC IECEN 60335-1 Tested in
1xx / 50/60Hz T105 IECEN 60335-2-6 appliance
BK3xxA36211 VDE
1xx
Control PCB (a) Eika BH3xx5360 220-240V IEC/EN 60335-1 Tested in
111xx 50/60Hz IEC/EN 60335-2-6 appliance
Alternative Diehl AKO Stiftung TC4 SE4 H 230V~ 50-60Hz IECEN 60335-2-6 3)
electronic & Co. KG 16° T105 PTI175 IECEN 60730-1 VDE
control board
Alt. control unit Diehl AKO Stiftung TC5-B-SV-4Z- 230V 50/60Hz IECEN 60730-1 VDE
& Co. *R-***** T 105 IECEN 60730-2-1
contact: 250V 10A IECEN 60335-1
relays 100 000 IECEN 60335-2-6
Alt. control unit Diehl AKO Stiftung TC5-B-SH-4Z- 230V 50/60Hz IECEN 60730-1 VDE
& Co. *R-***** T 105 IECEN 60730-2-1
contact: 250V 10A IECEN 60335-1
relays 100 000 IECEN 60335-2-6
Alt. control unit Diehl AKO Stiftung TC5-S-SH-3Z- 230V 50/60Hz IECEN 60730-1 VDE
& Co. 4R-***** T 105 IECEN 60730-2-1
contact: 250V 10A IECEN 60335-1
relays 100 000 IECEN 60335-2-6
Alt. control unit Diehl AKO Stiftung TC5-S-SL-4Z- 230V 50/60Hz IECEN 60730-1 VDE
& Co. *R-T**** T 105 IECEN 60730-2-1
contact: 250V 10A IECEN 60335-1
relays 100 000 IECEN 60335-2-6
Alt. control unit Diehl AKO Stiftung TC5-P-SL-4Z- 230V 50/60Hz IECEN 60730-1 VDE
& Co. *R-T**** T 105 IECEN 60730-2-1
contact: 250V 10A IECEN 60335-1
relays 100 000 IECEN 60335-2-6
Control PCB (a) EGO 75.13022.103 - IECEN 60335-1 Tested in
IECEN 60335-2-6 appliance

TRF No. IEC60335_2_6J


Page 108 of 118 Report No:247713

IEC 60335-2-6

Power PCB Eika S. Coop BN340D36211 208-240V~ IEC/EN 60730-1 VDE


(for horizontal 107 IEC/EN 60730-2- No: 846000-
mount, 4-zone 11 4520-0006/
without double IEC/EN 60335-1 157788
zone) IEC/EN 60335-2- Tested in
6 appliance
Power PCB Eika S. Coop BN340D36211 208-240V~ IEC/EN 60730-1 VDE
(for vertical 10B IEC/EN 60730-2- No: 846000-
mount, 4-zone 11 4520-0006/
without double IEC/EN 60335-1 157788
zone) IEC/EN 60335-2- Tested in
6 appliance
Relays
1)
Relay Schrack LNH30012 16A 250V CLA T70 IECEN 60255-1 VDE
IECEN 60255-2- Tested in
23 appliance
IECEN 60335-1
IECEN 60335-2-6
1)
Relay (a) Carlo Gavazzi M25 A 001 12 16A/250V IECEN 60255-1 VDE
16 (considered as IECEN 60255-2- Tested in
class 105 A) 23 appliance
IECEN 60335-1
IECEN 60335-2-6
1)
Relay (a) Omron G2RL-1-E 16A/250V/AC1 IECEN 60255-1 VDE
(considered as IECEN 60255-2- Tested in
class A) 23 appliance
IECEN 60335-1
IECEN 60335-2-6
1)
Relay (a) Matsushita JS1-12V 10A 230V CL.A IECEN 60255-1 VDE
T85 IECEN 60255-2- Tested in
23 appliance
IECEN 60335-1
IECEN 60335-2-6
1)
Relay (a) Matsushita JS1a-12V 10A 230V CL.A IECEN 60255-1 VDE
T85 IECEN 60255-2- Tested in
23 appliance
IECEN 60335-1
IECEN 60335-2-6
1)
Relay (a) Schrack RT314012 16A 250V CLA T70 IECEN 60255-1 VDE
IECEN 60255-2- Tested in
23 appliance
IECEN 60335-1
IECEN 60335-2-6
IECEN 60255-1 1)
Relay (a) NAIS JS1a-B-6V- 10A 250V 6Vdc VDE
H150 (considered as IECEN 60255-2- Tested in
class A) 23 appliance
IECEN 60335-1
IECEN 60335-2-6
IECEN 60255-1 1)
Relay (a) Schrack LNH33006 10A 250V 6Vdc VDE
(considered as IECEN 60255-2- Tested in
class A) 23 appliance
IECEN 60335-1
IECEN 60335-2-6

TRF No. IEC60335_2_6J


Page 109 of 118 Report No:247713

IEC 60335-2-6

IECEN 60255-1 1)
Relay (a) Schrack RFH34006 16A 250V 6Vdc VDE
(considered as IECEN 60255-2- Tested in
class A) 23 the
IECEN 60335-1 appliance
IECEN 60335-2-6
Relay (a) Finder 45.71.7.006.0 16A 250V IECEN 60255-1 IMQ, VDE
310 (considered as IECEN 60255-2- Tested in
class 105 A) 23 the
IECEN 60335-1 appliance
IECEN 60335-2-6
1)
Relay (a) Schrack RTH34012 18A 250V Cl.F IECEN 60255-1 VDE
IECEN 60255-2- Tested in
23 appliance
IECEN 60335-1
IECEN 60335-2-6
1)
Relay (a) Tyco T 7S V1H6- 6A 250V Cl.F IECEN 60255-1 VDE
12-WG IECEN 60255-2- Tested in
23 appliance
IECEN 60335-1
IECEN 60335-2-6
1)
Relay (a) Hongfa HF152F-T- 10A 250V Cl.F IECEN 60255-1 VDE
012-1HT 12V IECEN 60255-2- Tested in
23 appliance
IECEN 60335-1
IECEN 60335-2-6
1)
Relay (a) Hongfa HF152F-T- 16A 250V Cl.F IECEN 60255-1 VDE
012-1HTQ 12V IECEN 60255-2- Tested in
23 appliance
IECEN 60335-1
IECEN 60335-2-6
1)
Relay (a) Hongfa HF3FA 6A 250V Cl.F IECEN 60255-1 VDE
IECEN 60255-2- Tested in
23 appliance
IECEN 60335-1
IECEN 60335-2-6
1)
Relay (a) Hongfa HF115F-Q 18A 250V Cl.F IECEN 60255-1 VDE
IECEN 60255-2- Tested in
23 appliance
IECEN 60335-1
IECEN 60335-2-6
1)
Relay (a) Hongfa 881WP2-1AC- 17A 250V Cl.F IECEN 60255-1 VDE
F-C IECEN 60255-2- Tested in
23 appliance
IECEN 60335-1
IECEN 60335-2-6
1)
Relay (a) Matsushita JS1aP.../T 10A 250V Cl.F IECEN 60255-1 VDE
IECEN 60255-2- Tested in
23 appliance
IECEN 60335-1
IECEN 60335-2-6

TRF No. IEC60335_2_6J


Page 110 of 118 Report No:247713

IEC 60335-2-6

1)
Relay (a) Song Chuan 812HT-1A-C 10A 250V Cl.F IECEN 60255-1 VDE
E F12V IECEN 60255-2- Tested in
23 appliance
IECEN 60335-1
IECEN 60335-2-6
1)
Relay (a) Song Chuan 899-1CH-F-C 10A 250V Cl.F IECEN 60255-1 VDE
IECEN 60255-2- Tested in
23 appliance
IECEN 60335-1
IECEN 60335-2-6
1)
Relay (a) Song Chuan SG7 100 E12 16A 250V Cl.F IECEN 60255-1 VDE
IECEN 60255-2- Tested in
23 appliance
IECEN 60335-1
IECEN 60335-2-6
Capacitors
1)
Capacitor VISHAY WKO 4,7nF 250V Y2 IEC 60384-14 FI , tested
440V X1, T85 IECEN 60335-1 in the
IECEN 60335-2-6 appliance
1) 1)
Capacitor Murata DE2E3KH472 3300pF 250V IEC 60384-14 N ,S ,
1) 1)
M IECEN 60335-1 S+ , VDE ,
1) 1)
IECEN 60335-2-6 FI , D ,
tested in the
appliance
1) 1)
Capacitor (a) Murata KH332H 3300pF 250V IEC 60384-14 N ,S ,
1) 1)
X1/Y2 IECEN 60335-1 S+ , VDE ,
1) 1)
IECEN 60335-2-6 FI , D ,
tested in the
appliance
1) 1)
Capacitor Philips 336 2 MKP 0,1µF 275V X2 IEC 60384-14 N , FI ,
T100 IECEN 60335-1 tested in the
IECEN 60335-2-6 appliance
1)
Capacitor (a) Arcotronics 1.40.00 MKT 0,1µF 275V X2 IEC 60384-14 N , tested in
T100 IECEN 60335-1 the
IECEN 60335-2-6 appliance
Capacitor (a) VISHAY 33H2 R0637 0.1µF IEC 60384-14 CEBEC
275Vac T110
Capacitor (a) Arcotronics R.46 MKP X2 0.1µF IEC 60384-14 ENEC03,
SH 275Vac T110 IMQ
Capacitor (a) BC 22221166116 100nF 275V T105 IEC 60384-14 D
1109 MKP
338 2
X capacitor ARCOTRONIC Series R46 100nF X2 110°C IEC 60384-14 ENEC-IMQ

Alt. Vishay Röderstein Series F1710 100nF X1 110°C IEC 60384-14 VDE

Alt. Vishay BC- Series E12 100nF X2 110°C IEC 60384-14 ENEC-SGS
Components MKP339
Alt. Vishay BC- Series E12 100nF X2 125°C IEC 60384-14 ENEC-SGS
Components MKP339T
Y capacitor Vishay Draloric Serie WYO 4n7F Y2 125°C IEC 60384-14 VDE

Alt. Murata Serie KX 4n7F Y2 125°C IEC 60384-14 VDE

TRF No. IEC60335_2_6J


Page 111 of 118 Report No:247713

IEC 60335-2-6

EMI DEM FC710Y2 250V 0.47μF X2 IEC EN 122400 IMQ


suppression 2x10nF Y
filter 0.68MΩ T85
Transformers
1)
Transformer Avisor EI 42/14,5 Prim: 230V IECEN 61558-1 VDE
50/60Hz 5VA IECEN 61558-2-6
Sec: 9V Cl.B
Transformer (a) Mencarini TRP 01 Prim: 230V IECEN 60335-1 Tested for
50/60Hz IECEN 60335-2-6 use in the
Sec: 11V 7VA appliance
Cl.B
1)
Thermal cut out Tamura Kaken H130 2A 250V 136C IECEN 60 691 VDE
for the
transformer
1)
Transformer (a) Marschner FLG30.10/ Prim: 230V IECEN 61558-1 VDE ,
60216 (115+115) 50/60Hz IECEN 61558-2-6 tested in the
6VA IECEN 60335-1 appliance
Sec: 2*12V Cl.F IECEN 60335-2-6
1)
Transformer (a) Marschner FLG30.10/610 6VA 115+115V IECEN 61558-1 VDE ,
35-1 50/60Hz 2*12V~ IECEN 61558-2-6
Cl.F
1)
Transformer (a) ERA BV 030-… Prim: 230V IECEN 61558-1 VDE , S, FI,
type UI (115+115) 50/60Hz IECEN 61558-2-6 S+
30/10,5 Sec: 2*9V Cl.B
1)
Transformer (a) STEGER 08-1120 230V 50/60Hz Cl.F IECEN 61558-1 VDE
Transformer (a) ZAREL 2604 230V 50/60Hz 3VA IECEN 60335-1 Tested in
5/10V ta105/ClassF IECEN 60335-2-6 the
+ Annex G appliance
Transformer (a) Kaschke 451 761 230V IECEN 60335-1 Tested in
12V Class A IECEN 60335-2-6 the
+ Annex G appliance
Transformer (a) Zarel 03179675 230V IECEN 60335-1 Tested in
00321004 0-5-10V IECEN 60335-2-6 the
3VA 50/60Hz Cl F + Annex G appliance
Transformer (a) Kaschke 063.682 Class B 230V 50Hz IECEN 60335-1 Tested in
IECEN 60335-2-6 the
+ Annex G appliance
Transformer (a) Myrra 25544 85-285VAC / 5-12V IEC/EN60335-1 Tested in
cl. < 150 IEC/EN60335-2-6 appliance
VDE
Transformer (a) Myrra 25770 85-285VAC / 5-12V IEC/EN60335-1 Tested in
cl. < 150 IEC/EN60335-2-6 appliance
VDE
Transformer (a) Zarel 0321018 85-285VAC / 5-12V IEC/EN60335-1 Tested in
cl.B IEC/EN60335-2-6 appliance
VDE
1)
Fuse on power Italweber 410040 T40mA 250V IECEN 60127-1 VDE
PCB (Not to be
replaced by the
user)

TRF No. IEC60335_2_6J


Page 112 of 118 Report No:247713

IEC 60335-2-6

Fuse on power various 5x20 T60mA 250V IECEN 60335-1 Tested in


PCB (Not to be IECEN 60335-2-6 the
replaced by the appliance
user)
For variants no. 147 through 152 only
Heating element (hob element)
Heating element EGO 10.53211.xxx 2500/1100W IECEN 60335-1 VDE
230V IECEN 60335-2-6 Tested in
Ø250mm appliance
Heating element EIKA 2502333912 2500W / 1100W IECEN 60335-1 VDE
230V IECEN 60335-2-6 Tested in
Ø250mm appliance
Heating element EGO 10.52213.xxx 2400/1500W IECEN 60335-1 VDE
230V IECEN 60335-2-6 Tested in
Ø290mm appliance
Power and control PCB
PCB Control Eika BG3xx336011 208-240VAC IECEN 60335-1 Tested in
unit 1xx 16-10A 50/60Hz IECEN 60335-2-6 appliance
T105 VDE
PCB Control Eika BG3xx336011 208-240VAC IECEN 60335-1 Tested in
unit 1xx 16-10A 50/60Hz IECEN 60335-2-6 appliance
T105 VDE
Relays
Relay Tyco LNH33012-01 10A 250V~ IECEN 60255-1 VDE
Coil: 12Vd.c. IECEN 60255-2- Tested in
Cl.155/F 23 appliance
IECEN 60335-1
IECEN 60335-2-6
1) An asterisk indicates a mark that assures the agreed level of surveillance
(a) alternative component
2) Energy regulators have been tested in accordance with the conditions occurring in the appliance.
3) The control board can have different Code numbers: 714069, 714049, 714012, 714204, 714053,
714052, 714050 and 713364. These cose numbers indicate number of relays, timers, no timers
etc.

28.1 TABLE: Threaded part torque test P


Threaded part identification Diameter of thread Column number Applied torque ( Nm )
(mm) (I, II, or III)
Screw in supply terminal 3,83 II 1,2
Screw in cord anchorage 3,05 II 0,6
Screw on enclosure 4 II 1,2

TRF No. IEC60335_2_6J


Page 113 of 118 Report No:247713

IEC 60335-2-6

29.1 TABLE: Clearances P


Overvoltage category.... : II 
Type of insulation:
Rated impulse Min. cl Basic Functional Supplementary Reinforced Verdict / Remark
voltage (V): (mm)
2 500 1,5** 3.2 2.8 -- P
4 000 3,0** 15 P
*) The value is increased to 0,8mm for pollution degree 3
*) If the construction is affected by wear, distortion, movement of the parts or during assembly, the value is
increased by 0,5 mm

29.2 TABLE: Creepage distances, basic, supplementary and reinforced insulation P


Creepage distance
(mm)
Pollution degree
Working voltage
(V)
1 2 3 Type of insulation
Material group Material group
) ) )
I II IIIa/IIIb I II IIIa/IIIb B* S* R* Verdict
125 and 250 0,6 1,3 1,8 2,5 3,2 3,6 4,0 6   P
125 and 250 0,6 1,3 1,8 2,5 3,2 3,6 4,0  -  N/A
125 and 250 1,2 2,6 3,6 5,0 6,4 7,2 8,0   15 P
250 and 400 1,0 2,0 2,8 4,0 5,0 5,6 6,3 6   P
250 and 400 1,0 2,0 2,8 4,0 5,0 5,6 6,3  -  N/A
250 and 400 2,0 4,0 5,6 8,0 10,0 11,2 12,6   15.0 P
)
* , B=Basic, S=Supplementary and R=Reinforced

29.2 TABLE: Creepage distances, functional insulation P


Creepage distance
(mm)
Pollution degree
Working voltage
(V)
1 2 3
Material group Material group
I II IIIa/IIIb I II IIIa/IIIb Verdict / Remark
125 and 250 0,4 1,0 1,4 2,0 2,5 2,8 3,2 P / 2,8
250 and 400 0,8 1,6 2,2 3,2 4,0 4,5 5,0 P / 10.0

TRF No. IEC60335_2_6J


Page 114 of 118 Report No:247713

IEC 60335-2-6

30 TABLE: Resistance to heat and fire

Object/ Manufacturer/ Type/ Ball pressure test Glow wire test Glow-wire Glow- wire Needle Verdict
part No. trademark model °C (GWT) flammability index ignition - flame
°C (GWFI) temp. test
°C (GWIT) (NFT)
°C
75 125 cl. 11 cl. 19 550 650 750 850 550 650 750 850 675 775
+40 +25
te ti te ti

Energy Siebe MSA 163 0 0 x P


regulators Appliance V01

Energy Siebe MSA 163 0 0 x P


regulators Appliance V03

Energy Siebe MSA 163 0 0 x P


regulators Appliance 312

Energy Siebe MSA 163 0 0 x P


regulators Appliance 369

Switch EGO 135 0 0 x P

Plastic cover 75 x P
to terminals
Supply screw 125 0 0 x P
terminal
Cover of 75 x P
screw
terminal
DDS electronic board DDS218 and DDS151REL

Transformer 125 0 0 x P

TRF No. IEC60335_2_6J


Page 115 of 118 Report No:247713

IEC 60335-2-6

Object/ Manufacturer/ Type/ Ball pressure test Glow wire test Glow-wire Glow- wire Needle Verdict
part No. trademark model °C (GWT) flammability index ignition - flame
°C (GWFI) temp. test
°C (GWIT) (NFT)
°C
75 125 cl. 11 cl. 19 550 650 750 850 550 650 750 850 675 775
+40 +25
te ti te ti

Relay 125 0 0 x P

PCB 125 0 0 x x P

EIKA electronic board 8A 1..0 360….. or 8B.1..0 360….. or BJ(K)3..A36...1.. and DIEHL electronic board TC-4SE-Z-XX-YY-105-U230

PCB 125 0 0 x x P

Relay cover 125 0 0 x P

Zarel 125 0 0 x P
transformer
cover
X2 capacitor 125 0 0 x P

Plastic part 125 0 0 x P


of Kaschke
transformer
Coil support 125 0 0 x P

EGO electronic board 75.13061.201 (4 relays) or 75.13061.202 (5 relays)

PCB 105 0 0 x x P

Relay cover SCHRACK LNA 99 x P


333012

TRF No. IEC60335_2_6J


Page 116 of 118 Report No:247713

IEC 60335-2-6

Object/ Manufacturer/ Type/ Ball pressure test Glow wire test Glow-wire Glow- wire Needle Verdict
part No. trademark model °C (GWT) flammability index ignition - flame
°C (GWFI) temp. test
°C (GWIT) (NFT)
°C
75 125 cl. 11 cl. 19 550 650 750 850 550 650 750 850 675 775
+40 +25
te ti te ti

Relay SCHRACK LNA 125 0 0 x P


contact side 333012

Transformer ERA 109 x P


Cover
Transformer ERA 125 0 0 x P
Contact side
DIEHL electronic board TC3-Q-9T-4R-U230

Relay NAIS 125 0 0 x P

Relay 125 0 0 x P
FINDER
X2 capacitor 125 0 0 x P

PCB 125 0 0 x x P

Transformer 125 0 0 x P
(plastic part)
Coil frame 125 0 0 x P

DIEHL electronic board TC4 Standard H

PCB 125 0 0 x x P

TRF No. IEC60335_2_6J


Page 117 of 118 Report No:247713

IEC 60335-2-6

Object/ Manufacturer/ Type/ Ball pressure test Glow wire test Glow-wire Glow- wire Needle Verdict
part No. trademark model °C (GWT) flammability index ignition - flame
°C (GWFI) temp. test
°C (GWIT) (NFT)
°C
75 125 cl. 11 cl. 19 550 650 750 850 550 650 750 850 675 775
+40 +25
te ti te ti

Relay SCHRACK RFH34 125 0 0 x P


006

Relay SCHRACK LNH33 125 0 0 x P


0006

Transformer Kaschke 125 0 0 x P


(plastic parts)
X2 capacitor 125 0 0 x P

Coil frame 125 0 0 x P

Fast on cover 114 x P

EIKA electronic board: BJ3xxA36211101

PCB 125 0 0 x x P

Relay cover 125 0 0 x P

transformer 125 0 0 x P
bobbin
X2 capacitor 125 0 0 x P

TRF No. IEC60335_2_6J


Page 118 of 118 Report No:247713

IEC 60335-2-6

Object/ Manufacturer/ Type/ Ball pressure test Glow wire test Glow-wire Glow- wire Needle Verdict
part No. trademark model °C (GWT) flammability index ignition - flame
°C (GWFI) temp. test
°C (GWIT) (NFT)
°C
75 125 cl. 11 cl. 19 550 650 750 850 550 650 750 850 675 775
+40 +25
te ti te ti

Eika BN340D3621110x

PCB 125 0 0 X x P

Relay Song chuan 812HT 125 0 0 x P


Supplementary information:
1)
Parts of material classified at least HB40 or if relevant HBF
2)
Parts of material classified as V-0 or V-1
3)
Flame persisting longer than 2 s (= te – ti) need only be reported for unattended appliances
4)
Surrounding parts subjected to the needle-flame test of annex E
5)
Base material classified as V-0 or if relevant VTM-0
6)
The GWIT pre-selection option, the 850 °C GWFI pre-selection option, and the 850 °C GWT are not applicable for attended appliances

TRF No. IEC60335_2_6J


Page 1 of 16 Report No:247713

IEC60335_2_6J - ATTACHMENT
Clause Requirement – Test Result – Remark Verdict

ATTACHMENT TO TEST REPORT IEC 60335-2-6


EUROPEAN GROUP DIFFERENCES AND NATIONAL DIFFERENCES
(Household and similar electrical appliances – Safety –
Part 2: Particular requirements for stationary cooking ranges, hobs, ovens and similar appliances)
Differences according to : EN 60335-2-6: 2003 + A1:2003 + A2: 2008 + A11: 2010 + A12:2012
+ A13:2013 used in conjunction with
EN 60335-1:2012
EN 62233:2008
Attachment Form No. : EU_GD_IEC60335_2_6J_II
Attachment Originator : Electrosuisse
Master Attachment : 2013-11
Copyright © 2013 IEC System for Conformity Testing and Certification of Electrical Equipment
(IECEE), Geneva, Switzerland. All rights reserved.

IEC 60335-2-6J - ATTACHMENT EN 62233:2008


Clause Requirement + Test Result – Remark Verdict
EMF- ELECTROMAGNETICS FIELDS
The tested product also complies with the requirements of EN 62233:2008
Limit ……………100% Measured max. :…< 5% P

IEC 60335_2_6J - ATTACHMENT


Clause Requirement – Test Result – Remark Verdict
CENELEC COMMON MODIFICATIONS
6.1 Delete “class 0” and “class 01” P
7.1 Single-phase appliances to be connected to the P
supply mains: 230 V covered
Multi-phase appliances to be connected to the P
supply mains: 400 V covered
When the provisions of footnote a to Table 102 apply, the appliance shall be marked -
with: (EN 60335-2-6)
– the substance of “CAUTION: Hot surface”, or N/A

– symbol IEC 60417-5041 N/A

The warning label shall be put on the door of pyrolitic N/A


ovens and shall be visible during operation (EN
60335-2-6)
7.10 Devices used to start/stop operational functions of Models “R”, “C”, “M”, tactile P
the appliance distinguished from other manual feedback;
devices by means of shape, size, surface texture, Models “E”, visual + audible
position, etc. feedback.
An indication that the device has been operated is given by: -
Page 2 of 16 Report No:247713

IEC60335_2_6J - ATTACHMENT
Clause Requirement – Test Result – Remark Verdict

 a tactile feedback, or Models “R”, “C”, “M” P


 an audible and visual feedback Models “E” P
Devices used to stop operational functions of the P
appliance, if any, shall be distinguished from other
manual devices by means of shape, or size, or
surface texture, or position, etc. A tactile or an
audible and visual feedback shall give an indication
that the device has been operated. (EN 60335-2-6)
7.12 The instructions include the substance of the following: -
- this appliance can be used by children aged from 8 P
years and above and persons with reduced physical,
sensory or mental capabilities or lack of experience
and knowledge if they have been given supervision
or instruction concerning use of the appliance in a
safe way and understand the hazards involved
- children shall not play with the appliance P
- cleaning and user maintenance shall not be made P
by children without supervision
Instructions for use shall be provided with the appliance so that the appliance can be P
used safely (EN 60335-2-6)
It is necessary to take precautions during user P
maintenance, appropriate details shall be given
The instructions shall include the substance of the P
following: (EN 60335-2-6)
WARNING: The appliance and its accessible parts
become hot during use.
Care should be taken to avoid touching heating
elements.
Children less than 8 years of age shall be kept away
unless continuously supervised.
This appliance can be used by children aged from 8 P
years and above and persons with reduced physical,
sensory or mental capabilities or lack of experience
and knowledge if they have been given supervision
or instruction concerning use of the appliance in a
safe way and understand the hazards involved.
Children shall not play with the appliance. Cleaning
and user maintenance shall not be made by children
without supervision (EN 60335-2-6)
The instructions for hobs and ranges shall include P
the substance of the following: (EN 60335-2-6)
WARNING: Unattended cooking on a hob with fat or
oil can be dangerous and may result in fire.
NEVER try to extinguish a fire with water, but switch
off the appliance and then cover flame e.g. with a lid
or a fire blanket.
WARNING: Danger of fire: do not store items on the
cooking surfaces
Page 3 of 16 Report No:247713

IEC60335_2_6J - ATTACHMENT
Clause Requirement – Test Result – Remark Verdict

If the hob surface is of glass-ceramic or similar P


material and protects live parts, the instructions shall
include the substance of the following:
WARNING: If the surface is cracked, switch off the
appliance to avoid the possibility of electric shock.
(EN 60335-2-6)
The instructions for cooking ranges and ovens shall N/A
include the substance of the following:
During use the appliance becomes hot. Care should
be taken to avoid touching heating elements inside
the oven. (EN 60335-2-6)
The instructions for ovens shall include the N/A
substance of the following: (EN 60335-2-6)
WARNING: Accessible parts may become hot
during use. Young children should be kept away.
The instructions for ovens having doors with glass N/A
panels shall include the substance of the following:
(EN 60335-2-6)
Do not use harsh abrasive cleaners or sharp metal
scrapers to clean the oven door glass since they can
scratch the surface, which may result in shattering of
the glass.
If during the test of Clause 11, the temperature rise N/A
at the centre of the internal bottom surface of a
storage drawer exceeds that specified for handles
held for short periods in normal use, the instructions
shall state that these surfaces can get hot. (EN
60335-2-6)
The instructions for pyrolytic self-cleaning ovens N/A
shall state that excess spillage must be removed
before cleaning and shall specify which utensils can
be left in the oven during cleaning (EN 60335-2-6)
If, for cleaning, the manufacturer instructs the user N/A
to set the controls to a position higher than for
normal cooking purposes, the instructions shall state
that under such conditions the surfaces may get
hotter than usual and children should be kept away.
(EN 60335-2-6)
The instructions for ovens incorporating a fan with a N/A
guard that can be removed for cleaning shall state
that the oven must be switched off before removing
the guard and that, after cleaning, the guard must be
replaced in accordance with the instructions (EN
60335-2-6)
The instructions for ovens provided with a facility to N/A
use a temperature-sensing probe shall include the
substance of the following: (EN 60335-2-6)
Only use the temperature probe recommended for
this oven.
Page 4 of 16 Report No:247713

IEC60335_2_6J - ATTACHMENT
Clause Requirement – Test Result – Remark Verdict

The instructions for ovens that have shelves shall N/A


include details indicating the correct installation of
the shelves. (EN 60335-2-6)
The instructions for cooking ranges, hobs and ovens P
shall state that a steam cleaner is not to be used.
(EN 60335-2-6)
The instructions for induction hobs shall include the N/A
substance of the following: (EN 60335-2-6)
Metallic objects such as knives, forks, spoons and
lids should not be placed on the hob surface since
they can get hot.
The instructions for hobs incorporating a lid shall N/A
state that any spillage should be removed from the
lid before opening. They shall also state that the hob
surface should be allowed to cool before closing the
lid. (EN 60335-2-6)
The instructions for hobs incorporating halogen N/A
lamps shall warn the user not to stare at the hob
elements.
The instructions for hobs incorporating a pan N/A
detector shall include the substance of the following:
(EN 60335-2-6)
After use, switch off the hob element by its control
and do not rely on the pan detector.
If the appliance incorporates a lamp for illumination, N/A
and does not incorporate a switch providing full
disconnection under overvoltage category III
conditions, the instructions shall include the
substance of the following:
WARNING: Ensure that the appliance is switched
off before replacing the lamp to avoid the possibility
of electric shock. (EN 60335-2-6)
The instructions for hobs shall state that the P
appliance is not intended to be operated by means
of an external timer or separate remote-control
system. (EN 60335-2-6)
The instructions for hobs shall include the substance P
of the following: WARNING: Use only hob guards
designed by the manufacturer of the cooking
appliance or indicated by the manufacturer of the
appliance in the instructions for use as suitable or
hob guards incorporated in the appliance. The use
of inappropriate guards can cause accidents. (EN
60335-2-6)
The instructions for hobs incorporating an induction N/A
wok element shall contain a list of vessels that can
be used, unless the manufacturer provides a work
with the appliance. (EN 60335-2-6)
Page 5 of 16 Report No:247713

IEC60335_2_6J - ATTACHMENT
Clause Requirement – Test Result – Remark Verdict

7.12.Z101 Add the following new subclause before 7.12.1: The Corrigendum to EN 60335-2- P
specific instructions related to the safe operation of 6:2003/A11:2010, June 2012,
this appliance (as given in 7.12 of this standard) had changed “4 mm” to “at
shall be collated together in the front section of the least 3 mm”.
user instructions. The height of the characters,
measured on the capital letters, shall be at least 4
mm. (EN 60335-2-6)
These instructions shall also be available in an P
alternative format, e.g. on a website.
7.12.Z1 The specific instructions related to the safe P
operation of this appliance is collated together in the
front section of the user instructions
The height of the characters, measured on the P
capital letters, is at least 3 mm
These instructions are also available in an P
alternative format, e.g. on a website
7.14 The height of the triangle used with symbol IEC N/A
60417-5041 shall be at least 12 mm.
(EN 60335-2-6)
8.1.1 Also test probe 18 of EN 61032 is applied P
The appliance being in every possible position P
during the test
The force on the probe in the straight position is P
increased to 10 N when probe 18 is used
When using test probe 18 the appliance is fully P
assembled as in normal use without any parts
removed, and
parts intended to be removed for user maintenance P
are also not removed
Use of test probe B and probe 18 of IEC 61032: no P
contact with live parts (EN 60335-2-6)
8.2 Compliance is checked by applying the test probes P
of EN 61032
For built-in appliances and fixed appliances, the test P
probe B and probe 18 of EN 61032 are applied only
after installation
11.8 Footnotes to “External enclosure of motor-operated N/A
appliances” to be taken into account
11.101 Temperature rise of surfaces not exceed the values See appended table N/A
specified in Table 102 (EN 60335-2-6)
15.1.2 Appliances with an automatic cord reel tested with N/A
the cord in the most unfavourable position so that
the reeling of the wet cord may affect electrical
insulation during operation, the cord not being dried
before reeling
19.102 Thermal control by NTC: replace by resistor with N/A
middle of the range value (EN 60335-2-6)
Page 6 of 16 Report No:247713

IEC60335_2_6J - ATTACHMENT
Clause Requirement – Test Result – Remark Verdict

20.2 When using the test probe similar to test probe B N/A
with a circular stop face, the accessories and
detachable covers are removed
Test probe 18 applied with a force of 2,5N on the N/A
appliance fully assembled
Appliances are fully assembled as in normal N/A
operation without any parts removed.
(EN 60335-2-6)
20.101 Stability test with the oven in its intended position N/A
following manufacturer's instructions
(EN 60335-2-6)
20.Z101 Horizontally hinged oven doors of floor standing N/A
cooking ranges, when fully opened, shall not cause
a hazard. (EN 60335-2-6)
21.101 Inclination difference between empty inside and N/A
loaded in rest position shall not exceed 6°
(EN 60335-2-6)
21.102 In the third paragraph of the test specification, P
replace “The vessel” by “For hob elements, other
than induction wok elements, the vessel”.
(EN 60335-2-6)
22.12 Handles, knobs etc. fixed in a reliable manner so that P
they will not work loose in normal use if loosening
could result in a hazard (including ingestion or a
choking hazard for vulnerable people”. (EN 60335-2-
6)
22.122 Ovens with shelves that can be withdrawn shall be N/A
fitted with rest or stop positions
(EN 60335-2-6)
This requirement does not apply to shelves that are N/A
designed to contain liquids, such as roasting trays
and the like. (EN 60335-2-6)
24.1 Components comply with the safety requirements P
specified in the relevant standards as far as they
reasonably apply
The requirements of Clause 29 of this standard P
apply between live parts of components and
accessible parts of the appliance.
The requirements of 30.2 of this standard apply to P
parts of non-metallic material in components
including parts of non-metallic material supporting
current-carrying connections inside components
Components that have not been previously tested or P
do not comply with the standard for the relevant
component are tested according to the requirements
of 30.2
Page 7 of 16 Report No:247713

IEC60335_2_6J - ATTACHMENT
Clause Requirement – Test Result – Remark Verdict

Components that have been previously tested and shown to comply with the -
resistance to fire requirements in the standard for the relevant component need not
be retested provided that:
- the severity specified in the component standard is P
not less than the severity specified in 30.2, and
- the test report for the component states whether it P
complied with the standard for the relevant
component with or without flame, flames not
exceeding 2 s during the test are ignored
Unless components have been previously tested N/A
and found to comply with the relevant standard for
the number of cycles specified, they are tested in
accordance with 24.1.1 to 24.1.9
For components mentioned in 24.1.1 to 24.1.9, no N/A
additional tests specified in the relevant standard for
the component are necessary other than those
specified in 24.1.1 to 24.1.9
Components that have not been separately tested P
and found to comply with the relevant standard, and
components that are not marked or not used in P
accordance with their marking,
are tested in accordance with the conditions P
occurring in the appliance, the number of samples
being that required by the relevant standard
Lamp holders and starter holders that have not been N/A
previously tested and found to comply with the
relevant standard are tested as a part of the
appliance and additionally comply with the gauging
and interchangeability requirements of the relevant
standard under the conditions occurring in the
appliance
Where the relevant standard specifies these N/A
gauging and interchangeability requirements at
elevated temperatures, the temperatures measured
during the tests of Clause 11 are used
Plugs and socket-outlets and other connecting N/A
devices of interconnection cords are not
interchangeable with plugs and socket-outlets listed
in IEC/TR 60083 or IEC 60906-1, or
with connectors and appliance inlets complying with N/A
the standard sheets of IEC 60320-1,
if direct supply to these parts from the supply mains N/A
gives rise to a hazard
24.1.7 If the remote operation of the appliance is via a N/A
telecommunication network, the relevant standard
for the telecommunication interface circuitry in the
appliance is EN 41003
Page 8 of 16 Report No:247713

IEC60335_2_6J - ATTACHMENT
Clause Requirement – Test Result – Remark Verdict

Compliance with Clause 8 of this standard is not N/A


impaired by connecting the appliance to a device
covered by EN 41003
24.Z1 For motor running capacitors (IEC 60252-1 type P2) N/A
with a metallic enclosure having an overpressure
fuse the flame testing of internal plastic parts
supporting current carrying connections as required
in 30.2.2 and 30.2.3.1 is not necessary
25.6 Supply cords of single-phase portable appliances having a rated current not -
exceeding 16 A, fitted with a plug complying with the following standard sheets of
IEC/TR 60083:
- for Class I appliances: N/A
standard sheet C2b, C3b or C4 ............................ :
- for Class II appliances: N/A
standard sheet C5 or C6 ....................................... :
25.7 Rubber sheathed cords (60245 IEC 53) are not Not for outdoor used N/A
suitable for appliances intended to be used outdoors
or when they are liable to be exposed to significant
amount of ultraviolet radiation
Halogen-free thermoplastic compound sheathed supply cords have properties at -
least those of:
 halogen-free thermoplastic compound N/A
sheathed cords (H03Z1Z1H2-F or
H03Z1Z1-F), for appliances having a mass
not exceeding 3 kg
 halogen-free thermoplastic compound N/A
sheathed cords (H05Z1Z1H2-F or
H05Z1Z1-F), for other appliances
Cross-linked halogen-free compound sheathed N/A
supply cords have properties at least those of cross-
linked halogen-free compound sheathed cords
(H07ZZ-F)
26.11 Conductors connected by soldering are not N/A
considered to be positioned or fixed so that reliance
is not placed upon the soldering alone to maintain
them in position unless they are held in place near
the terminals independently of the solder
29.2 The macroenvironment in a domestic kitchen is P
pollution degree 2 (EN 60335-2-6)
The microenvironment inside the appliance may be pollution degree 2 P
pollution degree 2 or 3 (EN 60335-2-6)
29.3.Z1 Appliance constructed so that if there is a possibility N/A
of damaging the insulation during installation, the
insulation withstands the scratch and penetration
test of 21.2
32 Compliance regarding electromagnetic fields is P
checked according to EN 50366 or EN 62233
Page 9 of 16 Report No:247713

IEC60335_2_6J - ATTACHMENT
Clause Requirement – Test Result – Remark Verdict

Annex I, The appliance is supplied at rated voltage and N/A


19.I.101 operated under normal operation with each of the
fault conditions specified
The duration of the test is as specified in 19.7 N/A

ZA ANNEX ZA (NORMATIVE)
SPECIAL NATIONAL CONDITIONS

Norway
19.5 The test is also applicable to appliances intended to N/A
be permanently connected to fixed wiring

Norway
22.2 The second paragraph of this subclause, dealing N/A
with single-phase, permanently connected class I
appliances having heating elements, is not
applicable due to the supply system

All CENELEC countries


25.6 and Information concerning National plug and socket- Supply cord for fixed N/A
25.25 outlets is available from the CENELEC website. connection
Normative national requirements concerning plug
and socket-outlets are shown in the relevant
National standard

Ireland and United Kingdom


25.8 In the table, the lines for 10 A and 16 A are replaced by: -
> 10 and ≤ 13 1,25 P
> 13 and ≤ 16 1,5 P

ZB ANNEX ZB (INFORMATIVE)
A-DEVIATIONS

Ireland
25.6 These regulations apply to all plugs for domestic use To be checked before -
at a voltage of not less than 200 V and in general marketing in this country
allow only plugs complying with I.S. 401:1997, or
equivalent, to be fitted to domestic appliances
Page 10 of 16 Report No:247713

IEC60335_2_6J - ATTACHMENT
Clause Requirement – Test Result – Remark Verdict

United Kingdom
25.6 These regulations apply to all plugs for domestic use To be checked before -
at a voltage of not less than 200 V and in general marketing in this country
allow only plugs to BS 1363 to be fitted to domestic
appliances. It also allows plugs to BS 4573 and EN
50075 to be fitted to shavers and toothbrushes

ZC ANNEX ZC (NORMATIVE)
NORMATIVE REFERENCES TO INTERNATIONAL PUBLICATIONS WITH THEIR
CORRESPONDING EUROPEAN PUBLICATIONS
A list of referenced documents in this standard P

ZD ANNEX ZD (INFORMATIVE)
IEC and CENELEC CODE DESIGNATIONS FOR FLEXIBLE CORDS
A table with IEC and CENELEC code designations P
for flexible cords

ZE ANNEX ZE (INFORMATIVE)
SPECIFIC ADDITIONAL REQUIREMENTS FOR APPLIANCES AND MACHINES
INTENDED FOR COMMERCIAL USE
7.1 Business name and full address of the manufacturer N/A
and, where applicable, his authorized
representative........................................................ :
Model or type reference ........................................ : N/A

Serial number, if any ............................................. : N/A

Production year N/A

Designation of the appliance ................................. : N/A

7.12 Instructions provided with the appliance so that the N/A


appliance can be used safely
The instructions contain at least the following information: -
- the business name and full address of the N/A
manufacturer and, where applicable, his authorized
representative
- model or type reference of the appliance as N/A
marked on the appliance itself, except for the serial
number
- the designation of the appliance together with its N/A
explanation in case it is given by a combination of
letters and/or numbers
- the general description of the appliance, when N/A
needed due to the complexity of the appliance
Page 11 of 16 Report No:247713

IEC60335_2_6J - ATTACHMENT
Clause Requirement – Test Result – Remark Verdict

- specific precautions if required during installation, N/A


operation, adjusting, user maintenance, cleaning,
repairing or moving
- when needed drawings, diagrams, descriptions N/A
and explanations necessary for the safe use and
user maintenance of the appliance
- the possible reasonably foreseeable misuse and, N/A
whenever relevant, a warning against the effects it
may have on the safe use of the appliance
The words “Original instructions” appear on the N/A
language version(s) verified by the manufacturer or
by the authorized representative
When a translation of the original instructions has N/A
been provided by a person introducing the appliance
on the market; the meaning of the sentence
“Translation of the original instructions” appear in
the relevant instructions delivered with the appliance
The instructions for maintenance/service to be done N/A
by specialized personnel, mandated by the
manufacturer or the authorized representative may
be supplied in only one Community language which
the specialized personnel understand
The instructions indicate the type and frequency of N/A
inspections and maintenance required for safe
operation including the preventive maintenance
measures
7.12.ZE1 If needed for specific appliances, the following information to be given: -
 on use, transportation, assembly, dismantling N/A
when out of service, testing or foreseeable
breakdowns, if these operations have
consequences on stability of the appliance
in order to avoid overturning, falling or
uncontrolled movements of the appliance or
of its component parts
 on how to maintain adequate mechanical N/A
stability when in use, during transportation,
assembly, dismantling, scrapping and any
other action involving the appliance
 on the protective measures to be taken by the N/A
user, including, where appropriate, the
personal protective equipment to be
provided
 on the operating method to be followed in the N/A
event of accident or breakdown; if a
blockage is likely to occur the operating
method to safely unblock the appliance
 on the specifications on the spare parts to be N/A
used, when these affect the health and
safety of the operator
Page 12 of 16 Report No:247713

IEC60335_2_6J - ATTACHMENT
Clause Requirement – Test Result – Remark Verdict

 on airborne noise emissions, determined and declared in accordance with the -


relevant Part 2, which includes:
- the A-weighted emission sound pressure N/A
level at workstations, where this exceeds 70
dB(A) ......................................................... ;
- where this level does not exceed 70 dB(A), N/A
this fact is indicated
- the peak C-weighted instantaneous sound N/A
pressure value at workstations, where this
exceeds 63 Pa (130 dB in relation to 20
μPa) ........................................................... :
- the A-weighted sound power level emitted N/A
by the machinery, where the A-weighted
emission sound pressure level at
workstations exceeds 80 dB(A) ................. :
7.12.ZE2 The instructions includes a warning to disconnect N/A
the appliance from its power source during service
and when replacing parts
If the removal of the plug is foreseen, it is clearly N/A
indicated that the removal of the plug has to be such
that an operator can check from any of the points to
which he has access that the plug remains removed
If this is not possible, due to the construction of the N/A
appliance or its installation, a disconnection with a
locking system in the isolated position is provided
19.11.4.8 The appliance continues to operate, without causing N/A
any hazard to the user, from the same point in its
operating cycle at which the voltage fluctuation
occurred, or
a manual operation is required to restart it N/A

20.1 Appliances and their components and fittings have N/A


adequate mechanical stability during transportation,
assembly, dismantling and any other action involving
the appliance
20.2 Dangerous moving transmission parts safeguarded N/A
either by design or guards
When guards are used, they are fixed guards, N/A
interlocking movable guards or protective devices
Moving parts directly involved in the function of the appliance which cannot be made -
completely inaccessible fitted with:
- fixed guards or interlocking movable guards N/A
preventing access to those sections of the parts that
are not used in the work, and
- adjustable guards restricting access to those N/A
sections of the moving parts where access is
necessary
Page 13 of 16 Report No:247713

IEC60335_2_6J - ATTACHMENT
Clause Requirement – Test Result – Remark Verdict

Interlocking movable guards used where frequent N/A


access is required
21.1 Appliances and their components and fittings have N/A
adequate mechanical strength and is constructed to
withstand such rough handling that may be expected
in normal use, during transportation, assembly,
dismantling, scrapping and any other action
involving the appliance
22.ZE.1 For appliances provided with a seat, the seat gives N/A
adequate stability
The distance between the seat and the control N/A
devices capable of being adapted to the operator
22.ZE.2 For appliances provided with separate devices for N/A
the start and the stop functions, the stop function is
unambiguously identifiable and does always override
the start function
For appliances provided with one device performing N/A
the start and the stop function, the stop function is
unambiguously identifiable and does always override
the start function
22.ZE.3 Appliances designed in such a way that incorrect N/A
mounting is avoided, if this can lead to an unsafe
situation
If this is not possible, information on the correct N/A
mounting is given directly on the part and/or the
enclosure
22.ZE.4 Where the weight, size or shape prevents N/A
appliances from being moved manually, they are
fitted with attachments for lifting gear, or
so designed that they can be fitted with such N/A
attachments, or
be shaped in such a way that standard lifting gear N/A
can easily be used
Appliances to be moved manually are constructed or N/A
equipped so that they can be moved easily and
safely
22.ZE.5 The fixing systems of fixed guards which prevent N/A
access to dangerous moving transmission parts only
removable with the use of tools
If such guards have to be removed by the user for N/A
routine cleaning or maintenance their fixing systems
remain attached to the fixed guards or to the
machine after removal
Where possible, guards are incapable of remaining N/A
in place without their fixings
This does not apply if, after removal of the screws, N/A
or if the component is incorrectly repositioned, the
appliance becomes inoperative
Page 14 of 16 Report No:247713

IEC60335_2_6J - ATTACHMENT
Clause Requirement – Test Result – Remark Verdict

Movable guards are interlocked N/A

The interlocking devices prevent the start of N/A


hazardous appliance functions until the guards are
fixed in their position, and give a stop command
whenever they are no longer closed
Where it is possible for an operator to reach the danger zone before the risk due to -
hazardous appliance functions has ceased, movable guards associated with a guard
locking device in addition to an interlocking device that:
- prevents the start of hazardous appliance functions N/A
until the guard is closed and locked, and
- keeps the guard closed and locked until the risk of N/A
injury from the hazardous appliance functions has
ceased
Interlocking movable guards remain attached to the N/A
appliance when open, and
they are designed and constructed in such a way N/A
that they can be adjusted only by means of an
intentional action
22.ZE.6 Interlocking movable guards designed in such a way N/A
that the absence or failure of one of their
components prevents starting or stops the
hazardous appliance functions
The guard is opened to the extent needed to cause N/A
the interlocking to operate and is then closed, the
number of operations being defined in the specific
Part 2 ..................................................................... :
After this test any defect that may be expected in N/A
normal use is applied to the interlock system,
including interruption of the supply, only one defect
being simulated at a time
After these tests the interlock system is fit for further N/A
use
22.ZE.7 Adjustable guards restricting access to areas of the moving parts strictly necessary -
for the work are:
- adjustable manually or automatically, depending on N/A
the type of work involved, and
- readily adjustable without the use of tools N/A

22.ZE.8 In case of interruption, re-establishment after an N/A


interruption or fluctuation in whatever manner of the
power supply, the appliance does not restart
However, automatic restarting of the operation is N/A
allowed if the appliance may continue to operate,
without causing any hazard to the user, from the
same point in its operating cycle at which the voltage
interruption or fluctuation occurred
Page 15 of 16 Report No:247713

IEC60335_2_6J - ATTACHMENT
Clause Requirement – Test Result – Remark Verdict

22.ZE.9 Appliances fitted with means to isolate them from all N/A
energy sources
Such isolators are clearly identified, and N/A

they are capable of being locked if reconnection N/A


endanger persons
After the energy source is disconnected, it is N/A
possible to dissipate any energy remaining or stored
in the circuits of the appliance without risk to
persons

ZF ANNEX ZF (INFORMATIVE)
CRITERIA APPLIED FOR THE ALLOCATION OF PRODUCTS COVERED BY
STANDARDS IN THE EN 60335 SERIES UNDER LVD OR MD
List of standards under CENELEC/TC61 with the LVD P
allocation under the LVD (Low Voltage Directive) or
the MD (Machinery Directive) ................................ :

ZG ANNEX ZG (NORMATIVE)
UV APPLIANCES
The following modifications to this standard apply to N/A
appliances having UV emitters
This annex is not applicable to appliances covered N/A
by the scopes of IEC 60335-2-27, IEC 60335-2-59
or IEC 60335-2-109
7.12.ZG The instructions for appliances incorporating UVC N/A
emitters include the substance of the following:
WARNING — This appliance contains a UV emitter.
Do not stare at the light source
32 For appliances incorporating UV emitters the N/A
manufacturer delivers a declaration providing
evidence that the plastic material exposed to the
radiation is UV resistant

ZZ ANNEX ZZ (INFORMATIVE)
COVERAGE OF ESSENTIAL REQUIREMENTS OF EC DIRECTIVES
Description of the relation between this European P
standard and the LVD (Low Voltage Directive,
2006/95/EC) and the MD (Machinery Directive,
2006/42/EC)
Page 16 of 16 Report No:247713

IEC60335_2_6J - ATTACHMENT
Clause Requirement – Test Result – Remark Verdict

11.101 TABLE: Temperature rise limits for surfaces


Ambient (°C) :
Test voltage (V):
Surfaces of appliances situated not more Surfaces situated
than 850 mm above the floor after more than 850 mm
installation above the floor
Surface after installation
Front surfaces of Other parts
oven door

dT (K) Max. dT dT (K) Max. dT dT (K) Max. dT


(K) (K) (K)

Bare metal 40 45 45
Coated metal 45 55 55
Glass and ceramic 55 60 60
Plastic and plastic coating > 0,3 mm 60 65 65
Page 1 of 3 Report No:247713

Comparison of normal dimension and slim dimension - ATTACHMENT

the overall dimensions in above drawings also apply to drawings in following 2 pages.
Page 2 of 3 Report No:247713

Comparison of normal dimension and slim dimension - ATTACHMENT


Page 3 of 3 Report No:247713

Comparison of normal dimension and slim dimension - ATTACHMENT

“ACTUAL” indicate normal dimension; “NEW” indicate slim dimension


Page 1 of 31 Report No:247713

PHOTOGRAPH - ATTACHMENT

Type P58…… Model RV6300 Front view

Type P58…… Model RV6300 Rear view


Page 2 of 31 Report No:247713

PHOTOGRAPH - ATTACHMENT
Page 3 of 31 Report No:247713

PHOTOGRAPH - ATTACHMENT

Type P58…… Model RV6300 Internal view


Page 4 of 31 Report No:247713

PHOTOGRAPH - ATTACHMENT

Type P58…… Model MV…. Internal view

Type P58…… Model MV…. Switch


Page 5 of 31 Report No:247713

PHOTOGRAPH - ATTACHMENT

Type P58…… Model MV…. Energy regulator

Type P58…… Model EV6700 Front view


Page 6 of 31 Report No:247713

PHOTOGRAPH - ATTACHMENT

Type P58…… Model EV6700 Touch-touch control

Type P58…… Model EV6700 Rear view


Page 7 of 31 Report No:247713

PHOTOGRAPH - ATTACHMENT

Type P58…… Model EV6700 Internal view

Type P58…… Model EV6700 Electronic PGA 9901.1E1


Page 8 of 31 Report No:247713

PHOTOGRAPH - ATTACHMENT

Type P58…… Model EV6700, Rear view of PCB, behind transformer

Type P58…… Model EO6700 Front view


Page 9 of 31 Report No:247713

PHOTOGRAPH - ATTACHMENT

Type P58…… Model EO6700 Touch-touch control with timer

Type P58…… Model EO6700 Rear view


Page 10 of 31 Report No:247713

PHOTOGRAPH - ATTACHMENT

Type P58…… Model EO6700 Connection diagram next to terminals

Type P58…… Model EO6700 Terminal


Page 11 of 31 Report No:247713

PHOTOGRAPH - ATTACHMENT

Type P58…… Model EO6700 Internal view

Rear of Touch control DIEHL 701453


Page 12 of 31 Report No:247713

PHOTOGRAPH - ATTACHMENT

Front of Touch control DIEHL 701453 in contact with ceramic surface

Type P58…… Model EO5900 Front view


Page 13 of 31 Report No:247713

PHOTOGRAPH - ATTACHMENT

Type P58…… Model EO5900 Touch-touch control without timer

Rear of Touch-control EIKA


Page 14 of 31 Report No:247713

PHOTOGRAPH - ATTACHMENT

Transformer on EIKA touch-control

Type P58…… Model EO6800 Front view


Page 15 of 31 Report No:247713

PHOTOGRAPH - ATTACHMENT

Type P58…… Model EO6800 Rear view

Type P58…… Model EO6900 internal overview


Page 16 of 31 Report No:247713

PHOTOGRAPH - ATTACHMENT

EIKA Electronic board

Transformer of EIKA electronic board


Page 17 of 31 Report No:247713

PHOTOGRAPH - ATTACHMENT

Relays on EIKA electronic board

EIKA electronic board: display and touch control side.


Page 18 of 31 Report No:247713

PHOTOGRAPH - ATTACHMENT

DIEHL electronic board

DIEHL electronic board: display and touch control side


Page 19 of 31 Report No:247713

PHOTOGRAPH - ATTACHMENT

DIEHL electronic board: transformer side.

DIEHL electronic board: Relays.


Page 20 of 31 Report No:247713

PHOTOGRAPH - ATTACHMENT

DIEHL electronic board: TC4 Standard H

DIEHL electronic board: TC4 Standard H


Page 21 of 31 Report No:247713

PHOTOGRAPH - ATTACHMENT

DIEHL electronic board: TC4 Standard H

Metallic parts covering DIEHL electronic board: TC4 Standard H


Page 22 of 31 Report No:247713

PHOTOGRAPH - ATTACHMENT

Positioning of DIEHL electronic board: TC4 Standard H inside the appliance

Positioning of DIEHL electronic board: TC4 Standard H inside the appliance


Page 23 of 31 Report No:247713

PHOTOGRAPH - ATTACHMENT

EIKA electronic board: BJ3xxA36211101in appliance

EIKA electronic board: BJ3xxA36211101


Page 24 of 31 Report No:247713

PHOTOGRAPH - ATTACHMENT

EIKA electronic board: BJ3xxA36211101

Eika BH3715360111xx
Page 25 of 31 Report No:247713

PHOTOGRAPH - ATTACHMENT

EC6700 (prototype)

EC5500 (prototype)
Page 26 of 31 Report No:247713

PHOTOGRAPH - ATTACHMENT

PCB control unit (touch & display board)

PCB control unit (Relay control board)


Page 27 of 31 Report No:247713

PHOTOGRAPH - ATTACHMENT

PCB control unit (rear side)

New heating element from eika (left) and EGO (right)


Page 28 of 31 Report No:247713

PHOTOGRAPH - ATTACHMENT

New optional
bracket for
improved
fixing.

Without
optional
bracket for
improved
fixing.
Page 29 of 31 Report No:247713

PHOTOGRAPH - ATTACHMENT

New bracket
for improved
fixing.

Without
optional
bracket for
improved
fixing.
Page 30 of 31 Report No:247713

PHOTOGRAPH - ATTACHMENT

(1) BN340D3621110B (for P58, P75 only)


(2) BN340D36211107 (for P58, P75 only)
(3) BN330D36211107 (for P29 only)
(4) BN320D36211107 (for P29 only)
Page 31 of 31 Report No:247713

PHOTOGRAPH - ATTACHMENT

New control PCB BN340D36211107 in EO6400

New heating element from E.G.O (10.58213.004)


Page 1 of 3 Report No:247713

COMPONENT LIST FOR ELECTRONIC CONTROL UNIT 3 - ATTACHMENT


Page 2 of 3 Report No:247713

COMPONENT LIST FOR ELECTRONIC CONTROL UNIT 3 - ATTACHMENT


Page 3 of 3 Report No:247713

COMPONENT LIST FOR ELECTRONIC CONTROL UNIT 3 - ATTACHMENT