Title:: 100mm Dia Cast Iron Inlet / Outlet Pipes Half Round Channel

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

GENERAL NOTES

100mm th. reinforced concrete Selected filling well compacted


cover slab (mix. 1:2:4) and consolidated.
1. All dimensions to be checked on
900
600 x 450 mm cast 600 x 450 mm cast 150 600 150 site,written dimensions
ARCHITECTURAL NOTES
iron cover iron cover C to be followed in preference to the scaled
GROUND LEVEL Inlet pipe dimensions

900
2. All wall less tha 200mm thick to be

600 150
IN OUT
reinforced with hoop

1000mm
300 min
100mm dia half round
All Openings Schedule channel Benching PLAN AT TOP iron at every alternate course
Selected stone profile.
IN OUT FOR MANHOLE 3. All reinforced concrete work is to be in
Marker Text D1 D2 D3 D4 W1 W2

150
WORKING (Scale 1:50) accordnace with

75
C
Quantity 8 1 1 1 7 4 LEVEL
the satructural Engineer's details.

50 min
gl. support bracket built into
W x H Size 0.900×2.100 0.900×2.400 1.200×2.400 2.400×2.400 1.500×1.500 0.600×1.000 125mm thick concrete base
230mm thick block wall
PLAN 4. All Sanitary work is to be in accordance
(mix. 1:3:6). Depth to invert 150 D
Material Wooden Panel door Metal Casement Metal Casement Metal Casement Metal Casement Metal Casement L
(Scale 1:50) with M.O.H rules
level not more than 1500mm 25mm th. cement screed

450
Description Single leaf hinged Single leaf hinged Double leaf hinged Sliding door Sliding Window Top hung window finished smooth with steel float. 2000 and regulations
Concrete to foundation (mix 1:3:6) to SECTION THRU SOAK PIT 5. Where drains passes under Building or
be at thickness specified
SECTION THROUGH THE SEPTIC TANK L - L (Scale 1:50) drive way area,
pipes to be of cast iron or encased in
Selected filling in six layers well rammed
150mm concrete
3D Back View and consolidated into place. 6. All waste pipes and waste pipes are to
600 x 450 mm cast be in ducts and
iron cover
bends to have all cleaning eyes accessible
600 x 450mm cast iron covers
complete with frames from outside
Second hand G.C.I sheet 7. All windows and external glazed doors
or roofing felt
on ground floor to
have barglar proofing to architect's details

2,719
100mm dia agricultural
8. All door frames to be rebated and
IES-02 All Openings Schedule 1:1
Benching rendered 12mm
pipes laid with open
joints, minimum fall 1:10. TITLE :
moulded and be full
width of wall with moulded architrave to
100mm dia. half round
channel.
thick, finished smooth with
steel float
SELECTED STONE 150 DOWN TO 20mm PROPOSED SNA MILITARY
detail, provide
100mm thick R.C cover slab. HOSPITAL.
rubber door stopper to all doors
125 th. conc. foundation
150 900 4460 900 150 (mix 1:3:6). 9. Staircase and Lobby doors to be self
PLAN AT TOP closing and
SECTION C-C LONGITUDINAL SECTION THRU
(Scale 1:50) 10.LOCATION:
All internal Plaster SOMALI ARMY
to be two MILITARY
coats steel BARRACKS
(Scale 1:25) PERCOLATION TRENCH
float finished,
hour fire resistance
11.DESCRIPTION
All manhole with in: building area, drive
way SEPTIC
and parking,
DETAILS AND MANHOLES.
A to have heavy duty air tight covers and
C 600 x 450 mm cast double sealed.
Half round channel 100mm dia cast iron inlet / outlet pipes iron cover 12. Provide G.I. 125 X100 rainwater down
900 DRAWN BY : KIRUNDA CHARLES (AMISOM
GROUND LEVEL pipes and 125 x
L L SEPTIC TANK SCHEDULE 100 G.I box gutter with brackets etc where
DESIGNED BY: ALELE ANDREW (AMISOM)

230
Shown.

150
IN OUT No.of
L B D Capacity 13. All paintings to be three coats
B users Scale: NOT TO SCALE,

800

900
TO SOAK PIT $
L PERCOLATION 100mm dia. inlet / 20 2400 1200 1500 4220 Ltrs 14. Lay 1 layer of paving slabs 600 x 600

300
Invert level
TRENCHES outlet cast iron D onSheet
sand No.along the009
pipe Selected stone 30 3000 1500 1500 5880 Ltrs

150
L B perimeter
Drg. No.of Building
SNA HOSPITAL 009.

230

750
A C Concrete to foundation 40 3400 1700 1800 7240 Ltrs 15. Samples of fittings, material etc to be
(mix 1:3:6) to be at produced and
thickness specified SECTION A - A 600 50 3600 18001800 8600 Ltrs
150 900 230 3000 230 900 300 approved befor commencing work
PLAN (Scale 1:50) (Scale 1:50) CROSS SECTION THRU 16. All office window to have P.C cills, built
DRAIN PIPE TRENCH 100 4000 2000 2500 10,000Ltrs in P.V pelmet
A boxes and timber APPROVAL SIGNATORIES
internal window cills and
C skirtings SECTION : CHIEF OF DEFENCE FORCES SNA
Half round channel 100mm dia cast iron inlet / outlet pipes 17.NAME
Steel
: trusses/portal frames and purlins
to SIGNATURE:
be painted DATE:
Septic Tank Details with 2 coats of oil paint
Rear Elevation 1:100 Left Elevation 1:100 18. FireSECTION
fighting :equipements to be
CHIEF OF ENGINEERING SNA
L ROOF NOTES
provided
NAME : and installed

230
bySIGNATURE:
building Fire consultants

150
DATE:
IN G28 GI pre-painted roofing sheets on OUT MANHOLE SCHEDULE
19. These architectural drawings shall be
read inSECTION : SNA HOSPITAL DIRECTOR
50 x 75 purlins on
B Shallow conjunction with the structural drawings,

2000
NAME :

800
50 x100 Rafters on
50 x 100 Rafters on TO SOAK PIT $ Type
a b c Deep Extra Deep Electrical
SIGNATURE: DATE:
50 x 150 Tie beams on L PERCOLATION Depth to invert 0 - 600 600 - 900 900 -1800 1800 -4500 >4500
mechanical drawings, Bills of quantity and
Technical
75 x 100 Wall Plate. SECTION : AMISOM FORCE COMMANDER
Minimum length 600 750 1000 1200 1200
Roof slope 10° TRENCHES Minimum width 450 600 750 800 1200
specifications.
NAME : Any discrepancy shall be
reported

150
SIGNATURE: DATE:
L Ht above benching - - - 2000 2000 immediately to the architect.

230
Wall thickness 115 115 225 225 225 - 350 20. TheSECTION
ARCHITECT : AMISOMshall not accept
MISION any ENGINEER
HEADQUATER
+6,000
2 Roof A
+6,000
2 Roof
C Concrete base 100 100 150 300 300 - 450 LIABILITY
NAME :
of work
which has not been expressly instructed in
SIGNATURE: DATE:
WRITING (& has
accepted to proceed in writing) to
SECTION : AMISOM FORCE ENGINEERING
150 900 230 4000 230 900 600 SUPERVISE or for any
NAME :
ommissions or deviation from his drawings/
PLAN OF SEPTIC TANK (Scale 1:50) SIGNATURE:
technical DATE:
specifications. Nor shall he take
+3,000 +3,000
responsibility for works
1 Upper Floor 1 Upper Floor handled by other consultants/Contractors.

Revision History
Front Elevation 1:100 Right Elevation 1:100 RevID ChID Change Name Date
±0 ±0
0 Ground Floor 0 Ground Floor

-1,000 -1,000
GSPublisherVersion 0.0.100.100 -1 Foundation -1 Foundation

A Building Section 1:100 ARCHITECT:

1 2 3
1 2 3
3,000 2,800
3,000 2,800
6,000 1 2 3
6,000 200 2,800 200 2,600 200
3,000 2,800 Drawing Scale
200 2,800 200 2,600 200
Njawuzi George William
W1
D
200

200

200

D PROPOSED FAMILY HOUSE


200

14.9 3.0 Bukaaya Village


1,300

Katabi Town Council


BEDROOM 3 D
W1
3,700

3,500

Wakiso District
BEDROOM 1
3,000

D4
W1
3,700

4,600
200

ACCESS ROAD
Drawing Name
BEDROOM 2
W1

As shown
3,700
200

3.0
D1 C D1
2,100 200

C
D1

D1

WC
1,400
W2

SITTING ROOM WC
D1

W2

PROPOSED
10,500

10,500
2,100 200

A A C
3,400

BUILDING

7.0
10,500

11,700

11,700
2,100 200
15
14
13
12
11
10
9

A A
3,400

DOWN
W1

W1
8,600

200

A A
3,400

4.0
B D1
15R x 200
UP

2,400

14G x 250
WC 2.0
200

B
1
2
3
4
5
6
7
8

W2
200

D1
200
D1

3,200

0.5
B
3,200

MASTER
3,200

3,000

D2

DINING BEDROOM
1,500
W2

STORE
18.0
Drawing Status
3,200

A
200
1,000

1,000

A D3
1,200

1,200
W3
200

200

W1 Modified by Date
MASIGA CYRUS LARRY
A
200

200

W3

200 2,800 200 2,600 200 Checked by Date

200 4,400 200 1,000 200 3,000 3,000


6,000 6,000 Drawing Scale
As shown
Layout ID Revision
0. Ground Floor 1:100 1. Upper Floor 1:100 2. Roof 1:100 0. Site Layout 1:100 A.04.1